Cortico-fugal output from visual cortex promotes plasticity of innate motor behaviour.
Liu, Bao-Hua; Huberman, Andrew D; Scanziani, Massimo
2016-10-20
The mammalian visual cortex massively innervates the brainstem, a phylogenetically older structure, via cortico-fugal axonal projections. Many cortico-fugal projections target brainstem nuclei that mediate innate motor behaviours, but the function of these projections remains poorly understood. A prime example of such behaviours is the optokinetic reflex (OKR), an innate eye movement mediated by the brainstem accessory optic system, that stabilizes images on the retina as the animal moves through the environment and is thus crucial for vision. The OKR is plastic, allowing the amplitude of this reflex to be adaptively adjusted relative to other oculomotor reflexes and thereby ensuring image stability throughout life. Although the plasticity of the OKR is thought to involve subcortical structures such as the cerebellum and vestibular nuclei, cortical lesions have suggested that the visual cortex might also be involved. Here we show that projections from the mouse visual cortex to the accessory optic system promote the adaptive plasticity of the OKR. OKR potentiation, a compensatory plastic increase in the amplitude of the OKR in response to vestibular impairment, is diminished by silencing visual cortex. Furthermore, targeted ablation of a sparse population of cortico-fugal neurons that specifically project to the accessory optic system severely impairs OKR potentiation. Finally, OKR potentiation results from an enhanced drive exerted by the visual cortex onto the accessory optic system. Thus, cortico-fugal projections to the brainstem enable the visual cortex, an area that has been principally studied for its sensory processing function, to plastically adapt the execution of innate motor behaviours.
Near-infrared diffuse reflection systems for chlorophyll content of tomato leaves measurement
NASA Astrophysics Data System (ADS)
Jiang, Huanyu; Ying, Yibin; Lu, Huishan
2006-10-01
In this study, two measuring systems for chlorophyll content of tomato leaves were developed based on near-infrared spectral techniques. The systems mainly consists of a FT-IR spectrum analyzer, optic fiber diffuses reflection accessories and data card. Diffuse reflectance of intact tomato leaves was measured by an optics fiber optic fiber diffuses reflection accessory and a smart diffuses reflection accessory. Calibration models were developed from spectral and constituent measurements. 90 samples served as the calibration sets and 30 samples served as the validation sets. Partial least squares (PLS) and principal component regression (PCR) technique were used to develop the prediction models by different data preprocessing. The best model for chlorophyll content had a high correlation efficient of 0.9348 and a low standard error of prediction RMSEP of 4.79 when we select full range (12500-4000 cm -1), MSC path length correction method by the log(1/R). The results of this study suggest that FT-NIR method can be feasible to detect chlorophyll content of tomato leaves rapidly and nondestructively.
Cortico-fugal output from visual cortex promotes plasticity of innate motor behaviour
Liu, Bao-hua; Huberman, Andrew D.; Scanziani, Massimo
2017-01-01
The mammalian visual cortex massively innervates the brainstem, a phylogenetically older structure, via cortico-fugal axonal projections1. Many cortico-fugal projections target brainstem nuclei that mediate innate motor behaviours, but the function of these projections remains poorly understood1–4. A prime example of such behaviours is the optokinetic reflex (OKR), an innate eye movement mediated by the brainstem accessory optic system3,5,6, that stabilizes images on the retina as the animal moves through the environment and is thus crucial for vision5. The OKR is plastic, allowing the amplitude of this reflex to be adaptively adjusted relative to other oculomotor reflexes and thereby ensuring image stability throughout life7–11. Although the plasticity of the OKR is thought to involve subcortical structures such as the cerebellum and vestibular nuclei10–13, cortical lesions have suggested that the visual cortex might also be involved9,14,15. Here we show that projections from the mouse visual cortex to the accessory optic system promote the adaptive plasticity of the OKR. OKR potentiation, a compensatory plastic increase in the amplitude of the OKR in response to vestibular impairment11,16–18, is diminished by silencing visual cortex. Furthermore, targeted ablation of a sparse population of cortico-fugal neurons that specifically project to the accessory optic system severely impairs OKR potentiation. Finally, OKR potentiation results from an enhanced drive exerted by the visual cortex onto the accessory optic system. Thus, cortico-fugal projections to the brainstem enable the visual cortex, an area that has been principally studied for its sensory processing function19, to plastically adapt the execution of innate motor behaviours. PMID:27732573
Control of Hazards to Health From Laser Radiation
2006-01-01
compared to the calculated AEL. (2) Optically aided viewing. Viewing a laser beam with optical aids (other than ordinary eyeglasses or contact lenses ...resonant optical cavity. TB MED 524 8 b. Lenses , mirrors, cooling systems, shutters, and other accessories may be added to the system to obtain...procedures for laser optical systems (for example, mirrors, prisms, and lenses ) that employ Class 2 and Class 3a lasers, it is always good laser safety
Photothermal camera port accessory for microscopic thermal diffusivity imaging
NASA Astrophysics Data System (ADS)
Escola, Facundo Zaldívar; Kunik, Darío; Mingolo, Nelly; Martínez, Oscar Eduardo
2016-06-01
The design of a scanning photothermal accessory is presented, which can be attached to the camera port of commercial microscopes to measure thermal diffusivity maps with micrometer resolution. The device is based on the thermal expansion recovery technique, which measures the defocusing of a probe beam due to the curvature induced by the local heat delivered by a focused pump beam. The beam delivery and collecting optics are built using optical fiber technology, resulting in a robust optical system that provides collinear pump and probe beams without any alignment adjustment necessary. The quasiconfocal configuration for the signal collection using the same optical fiber sets very restrictive conditions on the positioning and alignment of the optical components of the scanning unit, and a detailed discussion of the design equations is presented. The alignment procedure is carefully described, resulting in a system so robust and stable that no further alignment is necessary for the day-to-day use, becoming a tool that can be used for routine quality control, operated by a trained technician.
Apollo experience report: Crew provisions and equipment subsystem
NASA Technical Reports Server (NTRS)
Mcallister, F.
1972-01-01
A description of the construction and use of crew provisions and equipment subsystem items for the Apollo Program is presented. The subsystem is composed principally of survival equipment, bioinstrumentation devices, medical components and accessories, water- and waste-management equipment, personal-hygiene articles, docking aids, flight garments (excluding the pressure garment assembly), and various other crew-related accessories. Particular attention is given to items and assemblies that presented design, development, or performance problems: the crew optical alinement sight system, the metering water dispenser, and the waste-management system. Changes made in design and materials to improve the fire safety of the hardware are discussed.
Optical diffuse reflectance accessory for measurements of skin tissue by near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
Marbach, R.; Heise, H. M.
1995-02-01
An optimized accessory for measuring the diffuse reflectance spectra of human skin tissue in the near-infrared spectral range is presented. The device includes an on-axis ellipsoidal collecting mirror with efficient illumination optics for small sampling areas of bulky body specimens. The optical design is supported by the results of a Monte Carlo simulation study of the reflectance characteristics of skin tissue. Because the results evolved from efforts to measure blood glucose noninvasively, the main emphasis is placed on the long-wavelength near-infrared range where sufficient penetration depth for radiation into tissue is still available. The accessory is applied for in vivo diffuse reflectance measurements.
NASA Astrophysics Data System (ADS)
Terry, Neil G.; Zhu, Yizheng; Brown, William J.; Wax, Adam
2008-02-01
Improved methods for detecting dysplasia, or pre-cancerous growth are a current clinical need, particularly in the esophagus. The currently accepted method of random biopsy and histological analysis provides only a limited examination of tissue in question while being coupled with a long time delay for diagnosis. Optical scattering spectroscopy, in contrast, allows for inspection of the cellular structure and organization of tissue in vivo. Fourierdomain angle-resolved low-coherence interferometry (a/LCI) is a novel scattering spectroscopy technique that provides quantitative depth-resolved morphological measurements of the size and optical density of the examined cell nuclei, which are characteristic biomarkers of dysplasia. Previously, the clinical viability of the a/LCI system was demonstrated by analysis of ex vivo human esophageal tissue in Barrett's esophagus patients using a portable a/LCI system. We present an adaptation of the portable a/LCI instrument that can be used in the accessory channel of a gastroscope, allowing for in vivo measurements to be taken. Modifications to the previous generation system include the use of an improved imaging spectrometer allowing for subsecond acquisition times and the redesign of the delivery fiber and imaging optics in order to fit in the accessory channel of a gastroscope. Accurate sizing of polystyrene microspheres and other preliminary results are presented, demonstrating promise as a clinically viable tool.
Damin, Craig A; Sommer, André J
2013-11-01
Advances in fiber optic materials have allowed for the construction of fibers and waveguides capable of transmitting infrared radiation. An investigation of the transmission characteristics associated with two commonly used types of infrared-transmitting fibers/waveguides for prospective use in a fiber/waveguide-coupled attenuated total internal reflection (ATR) probe was performed. Characterization of silver halide polycrystalline fiber optics and hollow silica waveguides was done on the basis of the transmission of infrared light using a conventional fiber optic coupling accessory and an infrared microscope. Using the fiber optic coupling accessory, the average percent transmission for three silver halide fibers was 18.1 ± 6.1% relative to a benchtop reflection accessory. The average transmission for two hollow waveguides (HWGs) using the coupling accessory was 8.0 ± 0.3%. (Uncertainties in the relative percent transmission represent the standard deviations.) Reduced transmission observed for the HWGs was attributed to the high numerical aperture of the coupling accessory. Characterization of the fibers/waveguides using a zinc selenide lens objective on an infrared microscope indicated 24.1 ± 7.2% of the initial light input into the silver halide fibers was transmitted. Percent transmission obtained for the HWGs was 98.7 ± 0.1%. Increased transmission using the HWGs resulted from the absence or minimization of insertion and scattering losses due to the hollow air core and a better-matched numerical aperture. The effect of bending on the transmission characteristics of the fibers/waveguides was also investigated. Significant deviations in the transmission of infrared light by the solid-core silver halide fibers were observed for various bending angles. Percent transmission greater than 98% was consistently observed for the HWGs at the bending angles. The combined benefits of high percent transmission, reproducible instrument responses, and increased bending tolerance indicated HWGs should be preferred in the construction of a fiber/waveguide-coupled ATR probe.
Jelínek, Filip; Arkenbout, Ewout A; Sakes, Aimée; Breedveld, Paul
2014-08-01
This review article provides a comprehensive overview and classification of minimally invasive surgical instruments with an accessory channel incorporating fibreoptics or another auxiliary device for various purposes. More specifically, this review was performed with the focus on the newly emerging field of optical biopsy, its objective being to discuss primarily the instruments capable of carrying out the optical biopsy and subsequent tissue resection. Instruments housing the fibreoptics for other uses, as well as instruments with an accessory channel capable of housing the fibreoptics instead of their original auxiliary device after relevant design modifications, supplement the review. The entire Espacenet and Scopus databases were searched, yielding numerous patents and articles on conceptual and existing instruments satisfying the criteria. The instruments were categorised based on the function the fibreoptics or the auxiliary device serves. On the basis of their geometrical placement with respect to the tissue resector or manipulator, the subcategories were further defined. This subdivision was used to identify the feasibility of performing the optical biopsy and the tissue resection in an accurate and successive fashion. In general, the existing concepts or instruments are regarded as limited with regard to such a functionality, either due to the placement of their accessory channel with or without the fibreoptics or due to the operational restrictions of their tissue manipulators. A novel opto-mechanical biopsy harvester, currently under development at Delft University of Technology, is suggested as a promising alternative, ensuring a fast and accurate succession of the optical and the mechanical biopsies of a flat superficial tissue. © IMechE 2014.
A Practical Guide to Experimental Geometrical Optics
NASA Astrophysics Data System (ADS)
Garbovskiy, Yuriy A.; Glushchenko, Anatoliy V.
2017-12-01
Preface; 1. Markets of optical materials, components, accessories, light sources and detectors; 2. Introduction to optical experiments: light producing, light managing, light detection and measuring; 3. Light detectors based on semiconductors: photoresistors, photodiodes in a photo-galvanic regime. Principles of operation and measurements; 4. Linear light detectors based on photodiodes; 5. Basic laws of geometrical optics: experimental verification; 6. Converging and diverging thin lenses; 7. Thick lenses; 8. Lens systems; 9. Simple optical instruments I: the eye and the magnifier, eyepieces and telescopes; 10. Simple optical instruments II: light illuminators and microscope; 11. Spherical mirrors; 12. Introduction to optical aberrations; 13. Elements of optical radiometry; 14. Cylindrical lenses and vials; 15. Methods of geometrical optics to measure refractive index; 16. Dispersion of light and prism spectroscope; 17. Elements of computer aided optical design; Index.
Fluoroscopic image-guided intervention system for transbronchial localization
NASA Astrophysics Data System (ADS)
Rai, Lav; Keast, Thomas M.; Wibowo, Henky; Yu, Kun-Chang; Draper, Jeffrey W.; Gibbs, Jason D.
2012-02-01
Reliable transbronchial access of peripheral lung lesions is desirable for the diagnosis and potential treatment of lung cancer. This procedure can be difficult, however, because accessory devices (e.g., needle or forceps) cannot be reliably localized while deployed. We present a fluoroscopic image-guided intervention (IGI) system for tracking such bronchoscopic accessories. Fluoroscopy, an imaging technology currently utilized by many bronchoscopists, has a fundamental shortcoming - many lung lesions are invisible in its images. Our IGI system aligns a digitally reconstructed radiograph (DRR) defined from a pre-operative computed tomography (CT) scan with live fluoroscopic images. Radiopaque accessory devices are readily apparent in fluoroscopic video, while lesions lacking a fluoroscopic signature but identifiable in the CT scan are superimposed in the scene. The IGI system processing steps consist of: (1) calibrating the fluoroscopic imaging system; (2) registering the CT anatomy with its depiction in the fluoroscopic scene; (3) optical tracking to continually update the DRR and target positions as the fluoroscope is moved about the patient. The end result is a continuous correlation of the DRR and projected targets with the anatomy depicted in the live fluoroscopic video feed. Because both targets and bronchoscopic devices are readily apparent in arbitrary fluoroscopic orientations, multiplane guidance is straightforward. The system tracks in real-time with no computational lag. We have measured a mean projected tracking accuracy of 1.0 mm in a phantom and present results from an in vivo animal study.
ERIC Educational Resources Information Center
Ruiz, Michael J.
1982-01-01
The camera presents an excellent way to illustrate principles of geometrical optics. Basic camera optics of the single-lens reflex camera are discussed, including interchangeable lenses and accessories available to most owners. Several experiments are described and results compared with theoretical predictions or manufacturer specifications.…
14 CFR 23.1163 - Powerplant accessories.
Code of Federal Regulations, 2013 CFR
2013-01-01
... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...
14 CFR 23.1163 - Powerplant accessories.
Code of Federal Regulations, 2014 CFR
2014-01-01
... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...
14 CFR 23.1163 - Powerplant accessories.
Code of Federal Regulations, 2011 CFR
2011-01-01
... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...
14 CFR 23.1163 - Powerplant accessories.
Code of Federal Regulations, 2012 CFR
2012-01-01
... section, be sealed to prevent contamination of the engine oil system and the accessory system. (b... engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with the... Controls and Accessories § 23.1163 Powerplant accessories. (a) Each engine mounted accessory must— (1) Be...
Battery control system for hybrid vehicle and method for controlling a hybrid vehicle battery
Bockelmann, Thomas R [Battle Creek, MI; Hope, Mark E [Marshall, MI; Zou, Zhanjiang [Battle Creek, MI; Kang, Xiaosong [Battle Creek, MI
2009-02-10
A battery control system for hybrid vehicle includes a hybrid powertrain battery, a vehicle accessory battery, and a prime mover driven generator adapted to charge the vehicle accessory battery. A detecting arrangement is configured to monitor the vehicle accessory battery's state of charge. A controller is configured to activate the prime mover to drive the generator and recharge the vehicle accessory battery in response to the vehicle accessory battery's state of charge falling below a first predetermined level, or transfer electrical power from the hybrid powertrain battery to the vehicle accessory battery in response to the vehicle accessory battery's state of charge falling below a second predetermined level. The invention further includes a method for controlling a hybrid vehicle powertrain system.
14 CFR 25.1163 - Powerplant accessories.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...
14 CFR 25.1163 - Powerplant accessories.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...
14 CFR 25.1163 - Powerplant accessories.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...
14 CFR 25.1163 - Powerplant accessories.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or sparking... to prevent rotation without interfering with the continued operation of the engine. [Doc. No. 5066... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
14 CFR 29.1163 - Powerplant accessories.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...
14 CFR 29.1163 - Powerplant accessories.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...
14 CFR 29.1163 - Powerplant accessories.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...
14 CFR 29.1163 - Powerplant accessories.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or...
Dynamic Imaging of the Eye, Optic Nerve, and Extraocular Muscles With Golden Angle Radial MRI
Smith, David S.; Smith, Alex K.; Welch, E. Brian; Smith, Seth A.
2017-01-01
Purpose The eye and its accessory structures, the optic nerve and the extraocular muscles, form a complex dynamic system. In vivo magnetic resonance imaging (MRI) of this system in motion can have substantial benefits in understanding oculomotor functioning in health and disease, but has been restricted to date to imaging of static gazes only. The purpose of this work was to develop a technique to image the eye and its accessory visual structures in motion. Methods Dynamic imaging of the eye was developed on a 3-Tesla MRI scanner, based on a golden angle radial sequence that allows freely selectable frame-rate and temporal-span image reconstructions from the same acquired data set. Retrospective image reconstructions at a chosen frame rate of 57 ms per image yielded high-quality in vivo movies of various eye motion tasks performed in the scanner. Motion analysis was performed for a left–right version task where motion paths, lengths, and strains/globe angle of the medial and lateral extraocular muscles and the optic nerves were estimated. Results Offline image reconstructions resulted in dynamic images of bilateral visual structures of healthy adults in only ∼15-s imaging time. Qualitative and quantitative analyses of the motion enabled estimation of trajectories, lengths, and strains on the optic nerves and extraocular muscles at very high frame rates of ∼18 frames/s. Conclusions This work presents an MRI technique that enables high-frame-rate dynamic imaging of the eyes and orbital structures. The presented sequence has the potential to be used in furthering the understanding of oculomotor mechanics in vivo, both in health and disease. PMID:28813574
Optical design of automotive headlight system incorporating digital micromirror device.
Hung, Chuan-Cheng; Fang, Yi-Chin; Huang, Ming-Shyan; Hsueh, Bo-Ren; Wang, Shuan-Fu; Wu, Bo-Wen; Lai, Wei-Chi; Chen, Yi-Liang
2010-08-01
In recent years, the popular adaptive front-lighting automobile headlight system has become a main emphasis of research that manufacturers will continue to focus great efforts on in the future. In this research we propose a new integral optical design for an automotive headlight system with an advanced light-emitting diode and digital micromirror device (DMD). Traditionally, automobile headlights have all been designed as a low beam light module, whereas the high beam light module still requires using accessory lamps. In anticipation of this new concept of integral optical design, we have researched and designed a single optical system with high and low beam capabilities. To switch on and off the beams, a DMD is typically used. Because DMDs have the capability of redirecting incident light into a specific angle, they also determine the shape of the high or low light beam in order to match the standard of headlight illumination. With collocation of the multicurvature reflection lens design, a DMD can control the light energy distribution and thereby reinforce the resolution of the light beam.
Xing, Q.
2016-07-11
Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. Themore » electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energydispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. Finally, for an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly affect the usability of the SEM.« less
Information or resolution: Which is required from an SEM to study bulk inorganic materials?
Xing, Q
2016-11-01
Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energy-dispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. For an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly improve the usability of the SEM. SCANNING 38:864-879, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xing, Q.
Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. Themore » electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energydispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. Finally, for an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly affect the usability of the SEM.« less
Loesel, R; Homberg, U
2001-10-15
The accessory medulla (AMe), a small neuropil in the insect optic lobe, has been proposed to serve a circadian pacemaker function analogous to the role of the suprachiasmatic nucleus in mammals. Building upon considerable knowledge of the circadian system of the cockroach Leucophaea maderae, we investigated the properties of AMe neurons in this insect with intracellular recordings combined with dye injections. Responses of neurons with processes in the AMe to visual stimuli, including stationary white light, moving objects, and polarized light were compared with the responses of adjacent medulla tangential neurons. Neurons with processes in the AMe and additional ramifications in the medulla strongly responded to stationary light stimuli and might, therefore, be part of photic entrainment pathways to the clock. Accessory medulla neurons lacking significant processes in the medulla but with projections to the midbrain or to the contralateral optic lobe, in contrast, responded weakly or not at all to light and, thus, seem to be part of the clock's output pathway. Two types of commissural neurons with tangential arborizations in both medullae were sensitive to polarized light, suggesting a role of these neurons in celestial navigation. Sidebranches in the AMae of one of the two cell types are discussed with respect to a possible involvement of the AMe in polarization vision. Finally, neurons responding to movement stimuli did not arborize in the AMe. The results show that the AMe receives photic input and support a role of this neuropil in circadian timekeeping functions. Copyright 2001 Wiley-Liss, Inc.
Note: Design and fabrication of a simple versatile microelectrochemical cell and its accessories
NASA Astrophysics Data System (ADS)
Rajan, Viswanathan; Neelakantan, Lakshman
2015-09-01
A microelectrochemical cell housed in an optical microscope and custom-made accessories have been designed and fabricated, which allows performing spatially resolved corrosion measurements. The cell assembly was designed to directly integrate the reference electrode close to the capillary tip to avoid air bubbles. A hard disk along with an old optical microscope was re-engineered into a microgrinder, which made the vertical grinding of glass capillary tips very easy. A stepper motor was customized into a microsyringe pump to dispense a controlled volume of electrolyte through the capillary. A force sensitive resistor was used to achieve constant wetting area. The functionality of the developed instrument is demonstrated by studying μ-electrochemical behavior of worn surface on AA2014-T6 alloy.
Solar internal lighting using optical collectors and fibers
NASA Astrophysics Data System (ADS)
Francini, F.; Fontani, D.; Jafrancesco, D.; Mercatelli, L.; Sansoni, P.
2006-08-01
A system exploiting solar energy, by means of optical collectors and fibres, has been applied for indoor illumination. The project has been called "The Sunflowers" for the property of solar collectors to track solar position during the day. Every "sunflower" contains several solar collectors, each of which is coupled to an optical fibre. The "Sunflower" is provided of mechanical systems and electric accessories for solar tracking. The light focused by the solar collector can be used in two possible ways: for internal illumination with direct solar light; otherwise it can be accumulated for lighting when the sun is not present. The first function is obtained coupling the optical collector to an optical fibre, which transports the solar light in selected points within the showcases. The second one consists in focusing solar light on a photovoltaic cell of the last generation type with high efficiency. In this configuration the photovoltaic cell converts the focused light into electric energy to be used for illumination in case of sun absence. A demonstrative installation has been realised applying this solar illumination system to museum lighting: a prototype has been tested in a prestigious museum in Florence.
14 CFR 25.1192 - Engine accessory section diaphragm.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm that...
14 CFR 25.1192 - Engine accessory section diaphragm.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm that...
14 CFR 25.1192 - Engine accessory section diaphragm.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm that...
49 CFR 393.22 - Combination of lighting devices and reflectors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical...) Prohibited combinations. (1) A turn signal lamp must not be combined optically with either a head lamp or... the turn signal lamp. (2) A turn signal lamp must not be combined optically with a stop lamp unless...
A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System
Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun
2016-01-01
We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad/(m⋅Pa). A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work. PMID:27916900
Lusch, Achim; Abdelshehid, Corollos; Hidas, Guy; Osann, Kathryn E; Okhunov, Zhamshid; McDougall, Elspeth; Landman, Jaime
2013-07-01
Recent advances in distal sensor technologies have made distal sensor ureteroscopes both commercially and technically feasible. We evaluated performance characteristics and optics of a new generation distal sensor Flex-X(C) (X(C)) and a standard flexible fiberoptic ureteroscope Flex-X(2) (X(2)), both from Karl Storz, Tuttlingen, Germany. The ureteroscopes were compared for active deflection, irrigation flow, and optical characteristics. Each ureteroscope was evaluated with an empty working channel and with various accessories. Optical characteristics (resolution, grayscale imaging, and color representation) were measured using United States Air Force test targets. We digitally recorded a renal porcine ureteroscopy and laser ablation of a stone with the X(2) and with the X(C). Edited footage of the recorded procedure was shown to different expert surgeons (n=8) on a high-definition monitor for evaluation by questionnaire for image quality and performance. The X(C) had a higher resolution than the X(2) at 20 and 10 mm 3.17 lines/mm vs 1.41 lines/mm, 10.1 vs 3.56, respectively (P=0.003, P=0.002). Color representation was better in the X(C). There was no difference in contrast quality between the two ureteroscopes. For each individual ureteroscope, the upward deflection was greater than the downward deflection both with and without accessories. When compared with the X(2), the X(C) manifested superior deflection and flow (P<0.0005, P<0.05) with and without accessory present in the working channel. Observers deemed the distal sensor ureteroscope superior in visualization in clear and bloody fields, as well as for illumination (P=0.0005, P=0.002, P=0.0125). In this in vitro and porcine evaluation, the distal sensor ureteroscope provided significantly improved resolution, color representation, and visualization in the upper urinary tract compared with a standard fiberoptic ureteroscope. The overall deflection was also better in the X(C), and deflection as well as flow rate was less impaired by the various accessories.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rickey, Daniel; Sasaki, David; Dubey, Arbind
Purpose: Three-dimensional printing has been implemented at our institution to create customized treatment accessories including shielding and bolus. In order to effectively use 3D printing, the topography of the patient must first be acquired. To this end, we have evaluated a low-cost structured-light 3D scanner in order to assess the clinical viability of this technology. Methods: For ease of use, the scanner (3D Systems, Sense 3D Scanner) was mounted in a simple gantry that guided its motion and maintained an optimum distance between the scanner and the object. To characterise the spatial accuracy of the scanner, we used a geometricmore » phantom and an anthropomorphic head phantom. The geometric phantom was machined from plastic and had overall dimensions of 24 cm by 15 cm and included a hemispherical and a tetrahedron protrusion roughly the dimensions of an average forehead and nose respectively. Meshes acquired by the optical scanner were compared to meshes generated from high-resolution CT images. Results: Scans were acquired in under one minute. Most of the optical scans contained noticeable artefacts although in most instances these were considered minor. Using an algorithm that calculated distances between the two meshes, we found most of the optical scanner measurements agreed with those from CT to within about 1 mm for the geometric phantom and to within about 2 mm for the head phantom. Conclusion: In summary, we deemed this scanner to be clinically acceptable and it has been used to design treatment accessories for several skin cancer patients.« less
Circadian organization in hemimetabolous insects.
Tomioka, Kenji; Abdelsalam, Salaheldin
2004-12-01
The circadian system of hemimetabolous insects is reviewed in respect to the locus of the circadian clock and multioscillatory organization. Because of relatively easy access to the nervous system, the neuronal organization of the clock system in hemimetabolous insects has been studied, yielding identification of the compound eye as the major photoreceptor for entrainment and the optic lobe for the circadian clock locus. The clock site within the optic lobe is inconsistent among reported species; in cockroaches the lobula was previously thought to be a most likely clock locus but accessory medulla is recently stressed to be a clock center, while more distal part of the optic lobe including the lamina and the outer medulla area for the cricket. Identification of the clock cells needs further critical studies. Although each optic lobe clock seems functionally identical, in respect to photic entrainment and generation of the rhythm, the bilaterally paired clocks form a functional unit. They interact to produce a stable time structure within individual insects by exchanging photic and temporal information through neural pathways, in which serotonin and pigment-dispersing factor (PDF) are involved as chemical messengers. The mutual interaction also plays an important role in seasonal adaptation of the rhythm.
Scalia, Frank; Rasweiler, John J; Danias, John
2015-08-15
To provide a modern description of the Chiropteran visual system, the subcortical retinal projections were studied in the short-tailed fruit bat, Carollia perspicillata, using the anterograde transport of eye-injected cholera toxin B subunit, supplemented by the silver-impregnation of anterograde degeneration following eye removal, and compared with the retinal projections of the mouse. The retinal projections were heavily labeled by the transported toxin in both species. Almost all components of the murine retinal projection are present in Carollia in varying degrees of prominence and laterality. The projections: to the superior colliculus, accessory optic nuclei, and nucleus of the optic tract are predominantly or exclusively contralateral; to the dorsal lateral geniculate nucleus and posterior pretectal nucleus are predominantly contralateral; to the ventral lateral geniculate nucleus, intergeniculate leaflet, and olivary pretectal nucleus have a substantial ipsilateral component; and to the suprachiasmatic nucleus are symmetrically bilateral. The retinal projection in Carollia is surprisingly reduced at the anterior end of the dorsal lateral geniculate and superior colliculus, suggestive of a paucity of the relevant ganglion cells in the ventrotemporal retina. In the superior colliculus, in which the superficial gray layer is very thin, the projection is patchy in places where the layer is locally absent. Except for a posteriorly located lateral terminal nucleus, the other accessory optic nuclei are diminutive in Carollia, as is the nucleus of the optic tract. In both species the cholera toxin labeled sparse groups of apparently terminating axons in numerous regions not listed above. A question of their significance is discussed. © 2015 Wiley Periodicals, Inc.
Assessment of Petrological Microscopes.
ERIC Educational Resources Information Center
Mathison, Charter Innes
1990-01-01
Presented is a set of procedures designed to check the design, ergonomics, illumination, function, optics, accessory equipment, and image quality of a microscope being considered for purchase. Functions for use in a petrology or mineralogy laboratory are stressed. (CW)
NASA Astrophysics Data System (ADS)
McMillan, Norman; O'Neill, Martina; Smith, Stephen; Hammond, John; Riedel, Sven; Arthure, Kevin; Smith, S.
2009-05-01
A TLDA-microvolume (transmitted light drop analyser) accessory for use with a standard UV-visible fibre spectrophotometer is described. The physics of the elegantly simple optical design is described along with the experimental testing of this accessory. The modelling of the arrangement is fully explored to investigate the performance of the drop spectrophotometer. The design optimizes the focusing to deliver the highest quality spectra, rapid and simple sample handling and, importantly, no detectable carryover on the single quartz drophead. Results of spectral measurements in a laboratory providing NIST standards show the closest correlation between modelled pathlength and experimental measurement for different drop volumes in the range 0.7-3 µl. This instrument accessory delivers remarkably accurate and reproducible results that are good enough to allow the accessory to be used for rapid pipette calibration to avoid the laborious weighing methods currently employed. Measurements on DNA standards and proteins are given to illustrate the main application area of biochemistry for this accessory. The accessory has a measurement range of at least 0-60 A units without sample dilution and, since there exists an accurate volume-pathlength relationship, the drop volume used in any specific measurement or assay should be optimized to minimize the photometric error. Studies demonstrate that the cleaning of the drophead with lab wipes results in no measurable carryover. This important practical result is confirmed from direct reading of the accessory and an analytical balance which was used to perform carryover studies. For further information on the TLDA please contact: Drop Technology, Unit 2, Tallaght Business Park, Whitestown, Dublin 24, Republic of Ireland. email: info@droptechnology.com.
Controlled Speed Accessory Drive demonstration program
NASA Technical Reports Server (NTRS)
Hoehn, F. W.
1981-01-01
A Controlled Speed Accessory Drive System was examined in an effort to improve the fuel economy of passenger cars. Concept feasibility and the performance of a typical system during actual road driving conditions were demonstrated. The CSAD system is described as a mechanical device which limits engine accessory speeds, thereby reducing parasitic horsepower losses and improving overall vehicle fuel economy. Fuel consumption data were compiled for fleets of GSA vehicles. Various motor pool locations were selected, each representing different climatic conditions. On the basis of a total accumulated fleet usage of nearly three million miles, an overall fuel economy improvement of 6 percent to 7 percent was demonstrated. Coincident chassis dynamometer tests were accomplished on selected vehicles to establish the effect of different accessory drive systems on exhaust emissions, and to evaluate the magnitude of the mileage benefits which could be derived.
Quality detection system and method of micro-accessory based on microscopic vision
NASA Astrophysics Data System (ADS)
Li, Dongjie; Wang, Shiwei; Fu, Yu
2017-10-01
Considering that the traditional manual detection of micro-accessory has some problems, such as heavy workload, low efficiency and large artificial error, a kind of quality inspection system of micro-accessory has been designed. Micro-vision technology has been used to inspect quality, which optimizes the structure of the detection system. The stepper motor is used to drive the rotating micro-platform to transfer quarantine device and the microscopic vision system is applied to get graphic information of micro-accessory. The methods of image processing and pattern matching, the variable scale Sobel differential edge detection algorithm and the improved Zernike moments sub-pixel edge detection algorithm are combined in the system in order to achieve a more detailed and accurate edge of the defect detection. The grade at the edge of the complex signal can be achieved accurately by extracting through the proposed system, and then it can distinguish the qualified products and unqualified products with high precision recognition.
21 CFR 876.5880 - Isolated kidney perfusion and transport system and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Isolated kidney perfusion and transport system and....5880 Isolated kidney perfusion and transport system and accessories. (a) Identification. An isolated kidney perfusion and transport system and accesssories is a device that is used to support a donated or a...
21 CFR 876.5880 - Isolated kidney perfusion and transport system and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Isolated kidney perfusion and transport system and....5880 Isolated kidney perfusion and transport system and accessories. (a) Identification. An isolated kidney perfusion and transport system and accesssories is a device that is used to support a donated or a...
21 CFR 892.5050 - Medical charged-particle radiation therapy system.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) intended for use in radiation therapy. This generic type of device may include signal analysis and display... accessories. (b) Classification. Class II. When intended for use as a quality control system, the film dosimetry system (film scanning system) included as an accessory to the device described in paragraph (a) of...
RAMAN SPECTROSCOPY-BASED METABOLOMICS: EVALUATION OF SAMPLE PREPARATION AND OPTICAL ACCESSORIES
The field of metabonomics/metabolomics involves observing endogenous metabolites from organisms that change in response to exposure to a stressor or chemical of interest. Methods are being developed for measuring the Raman spectra of low-concentration metabolites in urine. The ...
41 CFR 101-39.304 - Modification or installation of accessory equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., TRANSPORTATION, AND MOTOR VEHICLES 39-INTERAGENCY FLEET MANAGEMENT SYSTEMS 39.3-Use and Care of GSA Interagency Fleet Management System Vehicles § 101-39.304 Modification or installation of accessory equipment. The modification of a GSA Interagency Fleet Management System (IFMS) vehicle or the permanent installation of...
Code of Federal Regulations, 2014 CFR
2014-04-01
..., parts, firmware, software, and systems. 121.8 Section 121.8 Foreign Relations DEPARTMENT OF STATE...-items, components, accessories, attachments, parts, firmware, software, and systems. (a) An end-item is.... Firmware includes but is not limited to circuits into which software has been programmed. (f) Software...
Code of Federal Regulations, 2012 CFR
2012-04-01
..., parts, firmware, software and systems. 121.8 Section 121.8 Foreign Relations DEPARTMENT OF STATE...-items, components, accessories, attachments, parts, firmware, software and systems. (a) An end-item is.... Firmware includes but is not limited to circuits into which software has been programmed. (f) Software...
Code of Federal Regulations, 2013 CFR
2013-04-01
..., parts, firmware, software and systems. 121.8 Section 121.8 Foreign Relations DEPARTMENT OF STATE...-items, components, accessories, attachments, parts, firmware, software and systems. (a) An end-item is.... Firmware includes but is not limited to circuits into which software has been programmed. (f) Software...
Code of Federal Regulations, 2010 CFR
2010-04-01
..., parts, firmware, software and systems. 121.8 Section 121.8 Foreign Relations DEPARTMENT OF STATE...-items, components, accessories, attachments, parts, firmware, software and systems. (a) An end-item is.... Firmware includes but is not limited to circuits into which software has been programmed. (f) Software...
Code of Federal Regulations, 2011 CFR
2011-04-01
..., parts, firmware, software and systems. 121.8 Section 121.8 Foreign Relations DEPARTMENT OF STATE...-items, components, accessories, attachments, parts, firmware, software and systems. (a) An end-item is.... Firmware includes but is not limited to circuits into which software has been programmed. (f) Software...
Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian
2016-01-01
This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student’s t test was used to compare the length of Stensen’s duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen’s duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen’s duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen’s duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis. PMID:26913509
Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian
2016-01-01
This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student's t test was used to compare the length of Stensen's duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen's duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen's duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen's duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis.
Anomalous optic discs in a patient with a Dandy-Walker cyst.
Orcutt, J C; Bunt, A H
1982-03-01
A 19-month-old female infant with a Dandy-Walker cyst had anomalous optic discs, each of which appeared to divide to form an accessory optic nerve. The discs probably lie within the spectrum of anomalous discs including optic nerve aplasia and hypoplasia, megallopapillae, morning glory disc, optic disc dysplasia, and optic nerve colobomas. The association of anomalous optic discs with a Dandy-Walker cyst has not been previously recognized. The ocular and brain malformations in this patient likely occurred during the fourth to eighth week of gestation, when the retinal ganglion cell axons were penetrating the optic nerve, and the rhombic lips were enlarging in early cerebellar development. The etiology of these anomalies is not known; however, teratogens, sporadic events, and genetic disorders should be considered.
Role of the flocculus of the cerebellum in motor learning of the vestibulo-ocular reflex
NASA Technical Reports Server (NTRS)
Highstein, S. M.
1998-01-01
Structure-function studies at the systems level are an effective method for understanding the relationship of the central nervous system to behavior. Motor learning or adaptation of the vestibulo-ocular reflex is a clear example wherein this approach has been productive. During a vestibulo-ocular reflex the brain converts a head velocity signal, transduced through the vestibular semicircular canals, into an eye movement command delivered to the extraocular muscles. If the viewed target remains on the fovea of the retina, the reflex is compensatory, and its gain, eye velocity/head velocity, is one. When the image of the viewed object slips across the retina, visual acuity decreases, and the gain of the reflex, which is no longer one, is plastically adapted or adjusted until retinal stability is restored. The anatomic substrate for this plasticity thus involves brain structures in which visual-vestibular interaction can potentially occur, as well as vestibular and visual sensory and oculomotor motor structures. Further, it has been known for many years that removal of the flocculus of the cerebellum permanently precludes further vestibulo-ocular reflex adaptation, demonstrating the involvement of the cerebellum in this behavior. Maekawa and Simpson (J Neurophysiol 1973;36: 649-66) discovered that one visual input to the flocculus involved the accessory optic system and the inferior olive. Ensuing work has demonstrated that the visual signals used to adapt the vestibulo-ocular reflex are transmitted by this accessory optic system to the flocculus and subsequently to brain stem structures involved in vestibulo-ocular reflex plasticity. Presently the inclusive list of anatomic sites involved in vestibulo-ocular reflex circuitry and its adaptive plasticity is small. Our laboratory continues to believe that this behavior should be caused by interactions within this small class of neurons. By studying each class of identified neuron and its interactions with others within the list, we hope to ultimately understand the mechanisms used by the brain in the expression of this behavior.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... allies of commercial communications satellite components, systems, parts, accessories, attachments and... export to U.S. allies of commercial communications satellite components, systems, parts, accessories... associated technical data for commercial communications satellites, and who are so registered with the...
An improved ternary vector system for Agrobacterium-mediated rapid maize transformation.
Anand, Ajith; Bass, Steven H; Wu, Emily; Wang, Ning; McBride, Kevin E; Annaluru, Narayana; Miller, Michael; Hua, Mo; Jones, Todd J
2018-05-01
A simple and versatile ternary vector system that utilizes improved accessory plasmids for rapid maize transformation is described. This system facilitates high-throughput vector construction and plant transformation. The super binary plasmid pSB1 is a mainstay of maize transformation. However, the large size of the base vector makes it challenging to clone, the process of co-integration is cumbersome and inefficient, and some Agrobacterium strains are known to give rise to spontaneous mutants resistant to tetracycline. These limitations present substantial barriers to high throughput vector construction. Here we describe a smaller, simpler and versatile ternary vector system for maize transformation that utilizes improved accessory plasmids requiring no co-integration step. In addition, the newly described accessory plasmids have restored virulence genes found to be defective in pSB1, as well as added virulence genes. Testing of different configurations of the accessory plasmids in combination with T-DNA binary vector as ternary vectors nearly doubles both the raw transformation frequency and the number of transformation events of usable quality in difficult-to-transform maize inbreds. The newly described ternary vectors enabled the development of a rapid maize transformation method for elite inbreds. This vector system facilitated screening different origins of replication on the accessory plasmid and T-DNA vector, and four combinations were identified that have high (86-103%) raw transformation frequency in an elite maize inbred.
Sánchez-Criado, J E
1979-06-01
The in vitro oxidative metabolism of hypothalamus, olfactory and limbic systems from female rats in the estrous cycle have been measured. The accessory olfactory bulb becomes most active during diestrous when the hypothalamus reaches its lowest values.
Minakata, H; Shigeno, S; Kano, N; Haraguchi, S; Osugi, T; Tsutsui, K
2009-03-01
The optic gland, which is analogous to the anterior pituitary in the context of gonadal maturation, is found on the upper posterior edge of the optic tract of the octopus Octopus vulgaris. In mature octopus, the optic glands enlarge and secrete a gonadotrophic hormone. A peptide with structural features similar to that of vertebrate gonadotrophin-releasing hormone (GnRH) was isolated from the brain of octopus and was named oct-GnRH. Oct-GnRH showed luteinising hormone-releasing activity in the anterior pituitary cells of the Japanese quail Coturnix coturnix. Oct-GnRH immunoreactive signals were observed in the glandular cells of the mature optic gland. Oct-GnRH stimulated the synthesis and release of sex steroids from the ovary and testis, and elicited contractions of the oviduct. Oct-GnRH receptor was expressed in the gonads and accessory organs, such as the oviduct and oviducal gland. These results suggest that oct-GnRH induces the gonadal maturation and oviposition by regulating sex steroidogenesis and a series of egg-laying behaviours via the oct-GnRH receptor. The distribution and expression of oct-GnRH in the central and peripheral nervous systems suggest that oct-GnRH acts as a multifunctional modulatory factor in feeding, memory processing, sensory, movement and autonomic functions.
Teaching physics and understanding infrared thermal imaging
NASA Astrophysics Data System (ADS)
Vollmer, Michael; Möllmann, Klaus-Peter
2017-08-01
Infrared thermal imaging is a very rapidly evolving field. The latest trends are small smartphone IR camera accessories, making infrared imaging a widespread and well-known consumer product. Applications range from medical diagnosis methods via building inspections and industrial predictive maintenance etc. also to visualization in the natural sciences. Infrared cameras do allow qualitative imaging and visualization but also quantitative measurements of the surface temperatures of objects. On the one hand, they are a particularly suitable tool to teach optics and radiation physics and many selected topics in different fields of physics, on the other hand there is an increasing need of engineers and physicists who understand these complex state of the art photonics systems. Therefore students must also learn and understand the physics underlying these systems.
Sánchez-Criado, J E
1979-06-01
Female rats reared without sex odours from male rats have a five day stral cycle. With exposure to male odour the estral cycle is shortened from five to four days. This pheromonal effect is blocked on deafferenting the vomeronasal system by electrolytically damaging both accessory olfactory bulbs.
Young, S R; Martin, G R
1984-01-01
A wave optical model was used to analyse the scattering properties of avian retinal oil droplets. Computations for the near field region showed that oil droplets perform significant light collection in cone photoreceptors and so enhance outer segment photon capture rates. Scattering by the oil droplet of the principal cone of a double cone pair, combined with accessory cone dichroic absorption under conditions of transverse illumination, may mediate avian polarization sensitivity.
Witkin, J W
1987-01-01
The luteinizing hormone-releasing hormone (LHRH) system was examined immunocytochemically in olfactory bulbs of adult monkeys, including two New World species (squirrel monkey, Saimiri sciureus and owl monkey, Aotus trivirgatus) and one Old World species (cynomolgus macaque, Macaca fasciculata), and in the brain and nasal region of a fetal rhesus macaque Macaca mulatta. LHRH neurons and fibers were found sparsely distributed in the olfactory bulbs in all adult monkeys. There was more LHRH in the accessory olfactory bulb (which is absent in Old World monkeys). In the fetal macaque there was a rich distribution of LHRH neurons and fibers along the pathway of the nervus terminalis, anterior and ventral to the olfactory bulb, and in the nasal septum, with fibers branching into the olfactory epithelium. In addition, there were LHRH neurons and fibers in the optic nerve.
Smartphone schlieren and shadowgraph imaging
NASA Astrophysics Data System (ADS)
Settles, Gary S.
2018-05-01
Schlieren and shadowgraph techniques are used throughout the realm of scientific experimentation to reveal transparent refractive phenomena, but the requirement of large precise optics has kept them mostly out of reach of the public. New developments, including the ubiquity of smartphones with high-resolution digital cameras and the Background-Oriented Schlieren technique (BOS), which replaces the precise optics with digital image processing, have changed these circumstances. This paper demonstrates a number of different schlieren and shadowgraph setups and image examples based only on a smartphone, its software applications, and some inexpensive accessories. After beginning with a simple traditional schlieren system the emphasis is placed on what can be visualized and measured using BOS and digital slit-scan imaging on the smartphone. Thermal plumes, liquid mixing and glass are used as subjects of investigation. Not only recreational and experimental photography, but also serious scientific imaging can be done.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, G.L.; Milosevic, M.
Diffuse reflectance (DR), emission (E), and external reflectance (ER) FT-IR spectroscopies are powerful techniques for materials characterization and surface analysis provided the spectrometer can address the appropriate location on a specimen under conditions for which the resulting measurement is meaningful. Evacuable cells and transfer optics have been developed for this purpose for coupon studies under laboratory conditions where a well defined location on a specimen can be monitored by DR, E, or ER while the environment, i. e., temperature and atmosphere, of the specimen is rigorously controlled. The Spectropus system of remote sampling accessories has been developed to make similarmore » measurements on large flat or convex objects in ambient air or in environmental chambers with sufficient ease that meaningful statistical comparisons of spectra obtained from many locations on a specimen or from many specimens can be made. These two general techniques are complimentary and allow for the results of controlled laboratory experiments to be readily extended to inspection operations. Evacuable cells designs for DR, for combined DR and E, and for 75{degrees}-ER with polarized light are described. Complimentary use of these cells with functionally similar remote sensing accessories is demonstrated with applications including the preparation of ceramic BeO surfaces for adhesive bonding (DR), the determination of the extent of cure and the oxidative degradation of epoxy adhesives and composites (DR and E), and the determination of the oxidation rate of uranium metal in air, oxygen, and water vapor (ER).« less
21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...
Bernstein, Jacob G.; Allen, Brian D.; Guerra, Alexander A.; Boyden, Edward S.
2016-01-01
Optogenetics enables light to be used to control the activity of genetically targeted cells in the living brain. Optical fibers can be used to deliver light to deep targets, and LEDs can be spatially arranged to enable patterned light delivery. In combination, arrays of LED-coupled optical fibers can enable patterned light delivery to deep targets in the brain. Here we describe the process flow for making LED arrays and LED-coupled optical fiber arrays, explaining key optical, electrical, thermal, and mechanical design principles to enable the manufacturing, assembly, and testing of such multi-site targetable optical devices. We also explore accessory strategies such as surgical automation approaches as well as innovations to enable low-noise concurrent electrophysiology. PMID:26798482
Spinal Accessory Motor Neurons in the Mouse: A Special Type of Branchial Motor Neuron?
Watson, Charles; Tvrdik, Petr
2018-04-16
The spinal accessory nerve arises from motor neurons in the upper cervical spinal cord. The axons of these motor neurons exit dorsal to the ligamentum denticulatum and form the spinal accessory nerve. The nerve ascends in the spinal subarachnoid space to enter the posterior cranial fossa through the foramen magnum. The spinal accessory nerve then turns caudally to exit through the jugular foramen alongside the vagus and glossopharyngeal nerves, and then travels to supply the sternomastoid and trapezius muscles in the neck. The unusual course of the spinal accessory nerve has long prompted speculation that it is not a typical spinal motor nerve and that it might represent a caudal remnant of the branchial motor system. Our cell lineage tracing data, combined with images from public databases, show that the spinal accessory motor neurons in the mouse transiently express Phox2b, a transcription factor that is required for development of brain stem branchial motor nuclei. While this is strong prima facie evidence that the spinal accessory motor neurons should be classified as branchial motor, the evolutionary history of these motor neurons in anamniote vertebrates suggests that they may be considered to be an atypical branchial group that possesses both branchial and somatic characteristics. Anat Rec, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.
Strauß, Johannes
2017-11-01
Scolopidial sensilla in insects often form large sensory organs involved in proprioception or exteroception. Here the knowledge on Nebenorgans and accessory organs, two organs consisting of scolopidial sensory cells, is summarised. These organs are present in some insects which are model organisms for the physiology of mechanosensory systems (cockroaches and tettigoniids). Recent comparative studies documented the accessory organ in several taxa of Orthoptera (including tettigoniids, cave crickets, Jerusalem crickets) and the Nebenorgan in related insects (Mantophasmatodea). The accessory organ or Nebenorgan is usually a small organ of 8-15 sensilla located in the posterior leg tibia of all leg pairs. The physiological properties of the accessory organs and Nebenorgans are so far largely unknown. Taking together neuroanatomical and electrophysiological data from disparate taxa, there is considerable evidence that the accessory organ and Nebenorgan are vibrosensitive. They thus complement the larger vibrosensitive subgenual organ in the tibia. This review summarises the comparative studies of these sensory organs, in particular the arguments and criteria for the homology of the accessory organ and Nebenorgan among orthopteroid insects. Different scenarios of repeated evolutionary origins or losses of these sensory organs are discussed. Neuroanatomy allows to distinguish individual sensory organs for analysis of sensory physiology, and to infer scenarios of sensory evolution. Copyright © 2017 Elsevier Ltd. All rights reserved.
Modeling Magnetite Reflectance Spectra Using Hapke Theory and Existing Optical Constants
NASA Technical Reports Server (NTRS)
Roush, T. L.; Blewett, D. T.; Cahill, J. T. S.
2016-01-01
Magnetite is an accessory mineral found in terrestrial environments, some meteorites, and the lunar surface. The reflectance of magnetite powers is relatively low [1], and this property makes it an analog for other dark Fe- or Ti-bearing components, particularly ilmenite on the lunar surface. The real and imaginary indices of refraction (optical constants) for magnetite are available in the literature [2-3], and online [4]. Here we use these values to calculate the reflectance of particulates and compare these model spectra to reflectance measurements of magnetite available on-line [5].
Shah, Shiraz A; Alkhnbashi, Omer S; Behler, Juliane; Han, Wenyuan; She, Qunxin; Hess, Wolfgang R; Garrett, Roger A; Backofen, Rolf
2018-06-19
A study was undertaken to identify conserved proteins that are encoded adjacent to cas gene cassettes of Type III CRISPR-Cas (Clustered Regularly Interspaced Short Palindromic Repeats - CRISPR associated) interference modules. Type III modules have been shown to target and degrade dsDNA, ssDNA and ssRNA and are frequently intertwined with cofunctional accessory genes, including genes encoding CRISPR-associated Rossman Fold (CARF) domains. Using a comparative genomics approach, and defining a Type III association score accounting for coevolution and specificity of flanking genes, we identified and classified 39 new Type III associated gene families. Most archaeal and bacterial Type III modules were seen to be flanked by several accessory genes, around half of which did not encode CARF domains and remain of unknown function. Northern blotting and interference assays in Synechocystis confirmed that one particular non-CARF accessory protein family was involved in crRNA maturation. Non-CARF accessory genes were generally diverse, encoding nuclease, helicase, protease, ATPase, transporter and transmembrane domains with some encoding no known domains. We infer that additional families of non-CARF accessory proteins remain to be found. The method employed is scalable for potential application to metagenomic data once automated pipelines for annotation of CRISPR-Cas systems have been developed. All accessory genes found in this study are presented online in a readily accessible and searchable format for researchers to audit their model organism of choice: http://accessory.crispr.dk .
Lusch, Achim; Liss, Michael A; Greene, Peter; Abdelshehid, Corollos; Menhadji, Ashleigh; Bucur, Philip; Alipanah, Reza; McDougall, Elspeth; Landman, Jaime
2013-12-01
To evaluate performance characteristics and optics of a new generation high-definition distal sensor (HD-DS) flexible cystoscope, a standard-definition distal sensor (SD-DS) cystoscope, and a standard fiberoptic (FO) cystoscope. Three new cystoscopes (HD-DS, SD-DS, and FO) were compared for active deflection, irrigation flow, and optical characteristics. Each cystoscope was evaluated with an empty working channel and with various accessories. Optical characteristics (resolution, grayscale imaging, color representation, depth of field, and image brightness) were measured using United States Air Force (USAF)/Edmund Optics test targets and illumination meter. We digitally recorded a porcine cystoscopy in both clear and blood fields, with subsequent video analysis by 8 surgeons via questionnaire. The HD-DS had a higher resolution than the SD-DS and the FO at both 20 mm (6.35 vs 4.00 vs 2.24 line pairs/mm) and 10 mm (14.3 vs 7.13 vs 4.00 line pairs/mm) evaluations, respectively (P <.001 and P <.001). Color representation and depth of field (P = .001 and P <.001) were better in the HD-DS. When compared to the FO, the HD-DS and SD-DS demonstrated superior deflection up and irrigant flow with and without accessory present in the working channel, whereas image brightness was superior in the FO (P <.001, P = .001, and P <.001, respectively). Observers deemed the HD-DS cystoscope superior in visualization in clear and bloody fields, as well as for illumination. The new HD-DS provided significantly improved visualization in a clear and a bloody field, resolution, color representation, and depth of field compared to SD-DS and FO. Clinical correlation of these findings is pending. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasaki, David; Rickey, Daniel; Dubey, Arbind
Purpose: We describe the process by which our centre is currently implementing 3D printing and scanning technology for treatment accessory fabrication. This technology can increase efficiency and accuracy of accessory design, production and placement during daily use. Methods: A low-cost 3D printer and 3D optical scanner have been purchased and are being commissioned for clinical use. Commissioning includes assessing: the accuracy of the 3D scanner through comparison with high resolution CT images; the dosimetric characteristics of polylactic acid (PLA) for electron beams; the clinical utility of the technology, and; methods for quality assurance. Results: The agreement between meshes generated usingmore » the 3D scanner and CT data was within 2 millimeters for an anthropomorphic head phantom. In terms of electron beam attenuation, 1 centimetre of printed PLA was found equivalent to 1.17 cm of water. In proof-of-concept tests, several types of treatment accessories have been prototyped to date that will benefit from this technology. These include electron and photon bolus for areas with complex surface contours including the ear for electron treatments, the extremities for photon treatments and lead shielding for orthovoltage treatments. Imaging with CT and x-ray showed minimal defects, which will have no significant clinical impact. Geometric fidelity and fit to volunteers and patients was found to be excellent. Conclusions: 3D Printing and scanning can increase efficiency in the clinic for treatments requiring custom accessories. Customized boluses and shielding had excellent fit and reduced uncertainty in positioning.« less
Accessory mineral records of tectonic environments? (Invited)
NASA Astrophysics Data System (ADS)
Storey, C.; Marschall, H. R.; Enea, F.; Taylor, J.; Jennings, E. S.
2010-12-01
Accessory mineral research continues to gather momentum as we seek to unleash their full potential. It is now widely recognised that robust accessory minerals, such as zircon, rutile, titanite, allanite and monazite, are archives of important trace elements that can help deduce metamorphic reaction history in metapelites, metabasites and other rock types. Moreover, they are important carriers of certain trace elements and govern or influence the products of partial melting and of fluid-rock interaction (e.g. magmas and mineralisation) in settings like subduction zones and hydrothermal systems. Perhaps most importantly, they can often be dated using the U-Th-Pb system. More recently, radiogenic (Lu-Hf, Sm-Nd, Rb-Sr) and stable (O) isotope systems have been applied and have further pushed the utility of accessory mineral research. In this talk I will discuss some of these advances towards one particular aim: the use of detrital accessory minerals for fingerprinting tectonic environments. This is a particularly laudable aim in Precambrian rocks, for which the preservation potential of orogenic belts and fossil subduction zones and their diagnostic metamorphic rocks is low. The implication is that our understanding of plate tectonics, particularly in the Archaean, is biased by the preserved in-tact rock record. An analogy is that Jack Hills zircons record evidence of Earth’s crust some 400 Ma before the preserved rock record begins. I will focus on some recent advances and new data from rutile and also the mineral inclusion record within zircon, which shows great promise for petrologic interpretation.
Advanced Gas Turbine (AGT) powertrain system development for automotive applications
NASA Technical Reports Server (NTRS)
1980-01-01
Progress in the development of a gas turbine engine to improve fuel economy, reduce gaseous emissions and particulate levels, and compatible with a variety of alternate fuels is reported. The powertrain is designated AGT101 and consists of a regenerated single shaft gas turbine engine, a split differential gearbox and a Ford Automatic Overdrive production transmission. The powertrain is controlled by an electronic digital microprocessor and associated actuators, instrumentation, and sensors. Standard automotive accessories are driven by engine power provided by an accessory pad on the gearbox. Component/subsystem development progress is reported in the following areas: compressor, turbine, combustion system, regenerator, gearbox/transmission, structures, ceramic components, foil gas bearing, bearings and seals, rotor dynamics, and controls and accessories.
21 CFR 884.1690 - Hysteroscope and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
21 CFR 884.1690 - Hysteroscope and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
21 CFR 884.1690 - Hysteroscope and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
21 CFR 884.1690 - Hysteroscope and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
21 CFR 884.1690 - Hysteroscope and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
Transneuronal pathways to the vestibulocerebellum
NASA Technical Reports Server (NTRS)
Kaufman, G. D.; Mustari, M. J.; Miselis, R. R.; Perachio, A. A.
1996-01-01
The alpha-herpes virus (pseudorabies, PRV) was used to observe central nervous system (CNS) pathways associated with the vestibulocerebellar system. Retrograde transneuronal migration of alpha-herpes virions from specific lobules of the gerbil and rat vestibulo-cerebellar cortex was detected immunohistochemically. Using a time series analysis, progression of infection along polyneuronal cerebellar afferent pathways was examined. Pressure injections of > 20 nanoliters of a 10(8) plaque forming units (pfu) per ml solution of virus were sufficient to initiate an infectious locus which resulted in labeled neurons in the inferior olivary subnuclei, vestibular nuclei, and their afferent cell groups in a progressive temporal fashion and in growing complexity with increasing incubation time. We show that climbing fibers and some other cerebellar afferent fibers transported the virus retrogradely from the cerebellum within 24 hours. One to three days after cerebellar infection discrete cell groups were labeled and appropriate laterality within crossed projections was preserved. Subsequent nuclei labeled with PRV after infection of the flocculus/paraflocculus, or nodulus/uvula, included the following: vestibular (e.g., z) and inferior olivary nuclei (e.g., dorsal cap), accessory oculomotor (e.g., Darkschewitsch n.) and accessory optic related nuclei, (e.g., the nucleus of the optic tract, and the medial terminal nucleus); noradrenergic, raphe, and reticular cell groups (e.g., locus coeruleus, dorsal raphe, raphe pontis, and the lateral reticular tract); other vestibulocerebellum sites, the periaqueductal gray, substantia nigra, hippocampus, thalamus and hypothalamus, amygdala, septal nuclei, and the frontal, cingulate, entorhinal, perirhinal, and insular cortices. However, there were differences in the resulting labeling between infection in either region. Double-labeling experiments revealed that vestibular efferent neurons are located adjacent to, but are not included among, flocculus-projecting supragenual neurons. PRV transport from the vestibular labyrinth and cervical muscles also resulted in CNS infections. Virus propagation in situ provides specific connectivity information based on the functional transport across synapses. The findings support and extend anatomical data regarding vestibulo-olivo-cerebellar pathways.
Hybrid vehicle powertrain system with power take-off driven vehicle accessory
Beaty, Kevin D.; Bockelmann, Thomas R.; Zou, Zhanijang; Hope, Mark E.; Kang, Xiaosong; Carpenter, Jeffrey L.
2006-09-12
A hybrid vehicle powertrain system includes a first prime mover, a first prime mover driven power transmission mechanism having a power take-off adapted to drive a vehicle accessory, and a second prime mover. The second prime mover is operable to drive the power transmission mechanism alone or in combination with the first prime mover to provide power to the power take-off through the power transmission mechanism. The invention further includes methods for operating a hybrid vehicle powertrain system.
Sung, Yu-Lung; Jeang, Jenn; Lee, Chia-Hsiung; Shih, Wei-Chuan
2015-04-01
We present a highly repeatable, lithography-free and mold-free method for fabricating flexible optical lenses by in situ curing liquid polydimethylsiloxane droplets on a preheated smooth surface with an inkjet printing process. This method enables us to fabricate lenses with a focal length as short as 5.6 mm, which can be controlled by varying the droplet volume and the temperature of the preheated surface. Furthermore, the lens can be attached to a smartphone camera without any accessories and can produce high-resolution (1 μm) images for microscopy applications.
The petrographic microscope: Evolution of a mineralogical research instrument
Kile, D.E.
2003-01-01
The petrographic microscope, designed to observe and measure the optical properties of minerals as a means of identifying them, has provided a foundation for mineralogical and petrological research for more than 120 years. Much of what is known today in these fields is attributable to this instrument, the development of which paralleled an evolution of fundamental optical theory and its correlation with mineral structure and composition. This instrument and its related accessories have evolved through a range of models and designs, which are in themselves distinctive for their scientific function and elegant construction, and are today prized by collectors of scientific instruments.
A System to Enable the Blind to Work Independently on the Center Lathe.
ERIC Educational Resources Information Center
Guha, Sujoy K.; Anand, Sneh
1980-01-01
A study has shown that with suitable accessories to machines and appropriate work planning, totally blind machinists can perform varied tasks on a lathe independently. Based on the results of the study, simple accessories have been designed and tested for use with the center lathe. (Author/PHR)
Phylogenetic Distribution of CRISPR-Cas Systems in Antibiotic-Resistant Pseudomonas aeruginosa.
van Belkum, Alex; Soriaga, Leah B; LaFave, Matthew C; Akella, Srividya; Veyrieras, Jean-Baptiste; Barbu, E Magda; Shortridge, Dee; Blanc, Bernadette; Hannum, Gregory; Zambardi, Gilles; Miller, Kristofer; Enright, Mark C; Mugnier, Nathalie; Brami, Daniel; Schicklin, Stéphane; Felderman, Martina; Schwartz, Ariel S; Richardson, Toby H; Peterson, Todd C; Hubby, Bolyn; Cady, Kyle C
2015-11-24
Pseudomonas aeruginosa is an antibiotic-refractory pathogen with a large genome and extensive genotypic diversity. Historically, P. aeruginosa has been a major model system for understanding the molecular mechanisms underlying type I clustered regularly interspaced short palindromic repeat (CRISPR) and CRISPR-associated protein (CRISPR-Cas)-based bacterial immune system function. However, little information on the phylogenetic distribution and potential role of these CRISPR-Cas systems in molding the P. aeruginosa accessory genome and antibiotic resistance elements is known. Computational approaches were used to identify and characterize CRISPR-Cas systems within 672 genomes, and in the process, we identified a previously unreported and putatively mobile type I-C P. aeruginosa CRISPR-Cas system. Furthermore, genomes harboring noninhibited type I-F and I-E CRISPR-Cas systems were on average ~300 kb smaller than those without a CRISPR-Cas system. In silico analysis demonstrated that the accessory genome (n = 22,036 genes) harbored the majority of identified CRISPR-Cas targets. We also assembled a global spacer library that aided the identification of difficult-to-characterize mobile genetic elements within next-generation sequencing (NGS) data and allowed CRISPR typing of a majority of P. aeruginosa strains. In summary, our analysis demonstrated that CRISPR-Cas systems play an important role in shaping the accessory genomes of globally distributed P. aeruginosa isolates. P. aeruginosa is both an antibiotic-refractory pathogen and an important model system for type I CRISPR-Cas bacterial immune systems. By combining the genome sequences of 672 newly and previously sequenced genomes, we were able to provide a global view of the phylogenetic distribution, conservation, and potential targets of these systems. This analysis identified a new and putatively mobile P. aeruginosa CRISPR-Cas subtype, characterized the diverse distribution of known CRISPR-inhibiting genes, and provided a potential new use for CRISPR spacer libraries in accessory genome analysis. Our data demonstrated the importance of CRISPR-Cas systems in modulating the accessory genomes of globally distributed strains while also providing substantial data for subsequent genomic and experimental studies in multiple fields. Understanding why certain genotypes of P. aeruginosa are clinically prevalent and adept at horizontally acquiring virulence and antibiotic resistance elements is of major clinical and economic importance. Copyright © 2015 van Belkum et al.
Vacuum ellipsometry as a method for probing glass transition in thin polymer films.
Efremov, Mikhail Yu; Soofi, Shauheen S; Kiyanova, Anna V; Munoz, Claudio J; Burgardt, Peter; Cerrina, Franco; Nealey, Paul F
2008-04-01
A vacuum ellipsometer has been designed for probing the glass transition in thin supported polymer films. The device is based on the optics of a commercial spectroscopic phase-modulated ellipsometer. A custom-made vacuum chamber evacuated by oil-free pumps, variable temperature optical table, and computer-based data acquisition system was described. The performance of the tool has been demonstrated using 20-200 nm thick poly(methyl methacrylate) and polystyrene films coated on silicon substrates at 10(-6)-10(-8) torr residual gas pressure. Both polymers show pronounced glass transitions. The difficulties in assigning in the glass transition temperature are discussed with respect to the experimental challenges of the measurements in thin polymer films. It is found that the experimental curves can be significantly affected by a residual gas. This effect manifests itself at lower temperatures as a decreased or even negative apparent thermal coefficient of expansion, and is related to the uptake and desorption of water by the samples during temperature scans. It is also found that an ionization gauge--the standard accessory of any high vacuum system--can cause a number of spurious phenomena including drift in the experimental data, roughening of the polymer surface, and film dewetting.
New designs for portable Raman instrumentation in defense applications
NASA Astrophysics Data System (ADS)
Carron, Keith; Ray, Bryan; Buller, Shane; Strickland, Aaron
2016-05-01
The realization of global terrorism after the September 11 attacks led immediately to a need for rapid field analysis of materials. Colorimetric test kits existed, but they are very subjective to interpret and they require contact with the sample. A push for handheld spectrometers quickly led to FTIR systems with ATR sampling, handheld IMS systems, and handheld Raman spectrometers. No single technique solves all of the problems of field detection. We will discuss the development of Raman instrumentation and, in particular, cover the advantages and the problems that are inherent in Raman portability. Portable Raman instrumentation began with a limited number of accessories: a point-and-shoot and some sort of vial adaptor. Currently this has expanded to stand-off attachments for measurements at a distance, air sampling to look for toxic gasses or aerosols, Orbital Raster Scan (ORS) to spatially average over samples, SERS attachments for trace detection, and fiber optic probes.
Extending Raman's reach: enabling applications via greater sensitivity and speed
NASA Astrophysics Data System (ADS)
Creasey, David; Sullivan, Mike; Paul, Chris; Rathmell, Cicely
2018-02-01
Over the last decade, miniature fiber optic spectrometers have greatly expanded the ability of Raman spectroscopy to tackle practical applications in the field, from mobile pharmaceutical ID to hazardous material assessment in remote locations. There remains a gap, however, between the typical diode array spectrometer and their more sensitive benchtop analogs. High sensitivity, cooled Raman spectrometers have the potential to narrow that gap by providing greater sensitivity, better SNR, and faster measurement times. In this paper, we'll look at the key factors in the design of high sensitivity miniature Raman spectrometers and their associated accessories, as well as the key metric for direct comparison of these systems - limit of detection. With the availability of our high sensitivity Raman systems operating at wavelengths from the UV to NIR, many applications are now becoming practical in the field, from trace level detection to analysis of complex biological samples.
Self-contained microfluidic systems: a review.
Boyd-Moss, Mitchell; Baratchi, Sara; Di Venere, Martina; Khoshmanesh, Khashayar
2016-08-16
Microfluidic systems enable rapid diagnosis, screening and monitoring of diseases and health conditions using small amounts of biological samples and reagents. Despite these remarkable features, conventional microfluidic systems rely on bulky expensive external equipment, which hinders their utility as powerful analysis tools outside of research laboratories. 'Self-contained' microfluidic systems, which contain all necessary components to facilitate a complete assay, have been developed to address this limitation. In this review, we provide an in-depth overview of self-contained microfluidic systems. We categorise these systems based on their operating mechanisms into three major groups: passive, hand-powered and active. Several examples are provided to discuss the structure, capabilities and shortcomings of each group. In particular, we discuss the self-contained microfluidic systems enabled by active mechanisms, due to their unique capability for running multi-step and highly controllable diagnostic assays. Integration of self-contained microfluidic systems with the image acquisition and processing capabilities of smartphones, especially those equipped with accessory optical components, enables highly sensitive and quantitative assays, which are discussed. Finally, the future trends and possible solutions to expand the versatility of self-contained, stand-alone microfluidic platforms are outlined.
Alternative Fuels Data Center: Light-Duty Vehicle Idle Reduction Strategies
powered by lead-acid or lithium-ion batteries, are charged by the vehicle's engine when it is being driven and use battery power to run a vehicle's HVAC and other accessories without worrying about battery depletion. The systems monitor battery power levels while the engine is off and accessories powered by
Detection of Kaposi's Sarcoma Associated Herpesvirus Nucleic Acids Using a Smartphone Accessory
Mancuso, Matthew; Cesarman, Ethel; Erickson, David
2014-01-01
Kaposi's sarcoma (KS) is an infectious cancer occurring in immune-compromised patients, caused by Kaposi's sarcoma associated herpesvirus (KSHV). Our vision is to simplify the process of KS diagnosis through the creation of a smartphone based point-of-care system capable of yielding an actionable diagnostic readout starting from a raw biopsy sample. In this work we develop the sensing mechanism for the overall system, a smartphone accessory capable of detecting KSHV nucleic acids. The accessory reads out microfluidic chips filled with a colorimetric nanoparticle assay targeted at KSHV. We calculate that our final device can read out gold nanoparticle solutions with an accuracy of .05 OD, and we demonstrate that it can detect DNA sequences from KSHV down to 1 nM. We believe that through integration with our previously developed components, a smartphone based system like the one studied here can provide accurate detection information, as well as a simple platform for field based clinical diagnosis and research. PMID:25117534
Laghezza Masci, Valentina; Di Luca, Marco; Gambellini, Gabriella; Taddei, Anna Rita; Belardinelli, Maria Cristina; Guerra, Laura; Mazzini, Massimo; Fausto, Anna Maria
2015-07-01
The morphology and ultrastructure of female accessory reproductive glands of Anopheles maculipennis s.s., Anopheles labranchiae and Anopheles stephensi were investigated by light and electron microscopy. The reproductive system in these species is characterized by two ovaries, two lateral oviducts, a single spermatheca and a single accessory gland. The gland is globular and has a thin duct which empties into the vagina, near the opening of the spermathecal duct. Significant growth of the accessory reproductive gland is observed immediately after blood meal, but not at subsequent digestion steps. At ultrastructural level, the gland consists of functional glandular units belonging to type 3 ectodermal glands. The secretory cells are elongated and goblet shaped, with most of their cytoplasm and large nucleus in the basal part, close to the basement lamella. Finely fibrous electron-transparent material occupies the secretory cavity that is in contact with the end of a short efferent duct (ductule) emerging from the gland duct. The present study is the first detailed description of female accessory gland ultrastructure in Anophelinae and provides insights into the gland's functional role in the reproductive biology of these insects. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modeling and Simulation of Two Wheelchair Accessories for Pushing Doors.
Abdullah, Soran Jalal; Shaikh Mohammed, Javeed
2017-03-27
Independent mobility is vital to individuals of all ages, and wheelchairs have proven to be great personal mobility devices. The tasks of opening and navigating through a door are trivial for healthy people, while the same tasks could be difficult for some wheelchair users. A wide range of intelligent wheelchair controllers and systems, robotic arms, or manipulator attachments integrated with wheelchairs have been developed for various applications, including manipulating door knobs. Unfortunately, the intelligent wheelchairs and robotic attachments are not widely available as commercial products. Therefore, the current manuscript presents the modeling and simulation of a novel but simple technology in the form of a passive wheelchair accessory (straight, arm-like with a single wheel, and arc-shaped with multiple wheels) for pushing doors open from a wheelchair. From the simulations using different wheel shapes and sizes, it was found that the arc-shaped accessory could push open the doors faster and with almost half the required force as compared to the arm-like accessory. Also, smaller spherical wheels were found to be best in terms of reaction forces on the wheels. Prototypes based on the arc-shaped accessory design will be manufactured and evaluated for pushing doors open and dodging or gliding other obstacles.
Multicenter comparative trial of the V-scope system for therapeutic ERCP.
Joyce, A M; Ahmad, N A; Beilstein, M C; Kochman, M L; Long, W B; Baron, T; Sherman, S; Fogel, E; Lehman, G A; McHenry, L; Watkins, J; Ginsberg, G G
2006-07-01
A new duodenoscope (the V-scope), with a modified elevator used in combination with a dedicated short guide wire, constitutes the V-system. This system is intended to allow fixation of the guide wire at the elevator lever, thereby enhancing the speed and reliability of accessory exchange over a guide wire during ERCP. The aim of this study was to evaluate the extent to which the V-system provides improved efficiency in comparison with conventional duodenoscope and guide wire combinations. This was an industry-sponsored multicenter randomized trial. Patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) procedures in which treatment was anticipated were randomly assigned to the V-system or to a conventional duodenoscope and accessories used routinely in each center. The parameters recorded included the total case time, fluoroscopy time, catheter/guide wire exchange time, guide wire repositioning, loss of guide wire access, and success or failure of guide wire fixation when using the V-system. Fifty patients were included, 22 in the conventional group and 28 in the V-system group. A total of 135 exchanges were carried out. The patients had up to six exchanges. The median exchange time was 19.4 s with the V-system and 31.7 s with the conventional systems ( P < 0.001). Guide wire repositioning was required less often in the V-system group ( P = 0.0005). The V-system effectively locked the guide wire in 63 of 71 exchanges (89 %). Loss of guide wire access occurred in two patients in the conventional group and four in the V-system group, attributable to failure to lock the guide wire early during the experience (no significant differences). The V-system can effectively secure the guide wire during accessory exchange in ERCP and reduces the time required to exchange accessories. This may enhance overall efficiency during ERCP.
A New Integrated Onboard Charger and Accessory Power Converter for Plug-in Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Gui-Jia; Tang, Lixin
2014-01-01
In this paper, a new approach is presented for integrating the function of onboard battery charging into the traction drive system and accessory dc-dc converter of a plug-in electric vehicle (PEV). The idea is to utilize the segmented traction drive system of a PEV as the frond converter of the charging circuit and the transformer and high voltage converter of the 14 V accessory dc-dc converter to form a galvanically isolated onboard charger. Moreover, a control method is presented for suppressing the battery current ripple component of twice the grid frequency with the reduced dc bus capacitor in the segmentedmore » inverter. The resultant integrated charger has lower cost, weight, and volume than a standalone charger due to a substantially reduced component count. The proposed integrated charger topology was verified by modeling and experimental results on a 5.8 kW charger prototype.« less
Razza, Sergio; Zaccone, Monica; Meli, Aannalisa; Cristofari, Eliana
2017-12-01
Children affected by hearing loss can experience difficulties in challenging and noisy environments even when deafness is corrected by Cochlear implant (CI) devices. These patients have a selective attention deficit in multiple listening conditions. At present, the most effective ways to improve the performance of speech recognition in noise consists of providing CI processors with noise reduction algorithms and of providing patients with bilateral CIs. The aim of this study was to compare speech performances in noise, across increasing noise levels, in CI recipients using two kinds of wireless remote-microphone radio systems that use digital radio frequency transmission: the Roger Inspiro accessory and the Cochlear Wireless Mini Microphone accessory. Eleven Nucleus Cochlear CP910 CI young user subjects were studied. The signal/noise ratio, at a speech reception threshold (SRT) value of 50%, was measured in different conditions for each patient: with CI only, with the Roger or with the MiniMic accessory. The effect of the application of the SNR-noise reduction algorithm in each of these conditions was also assessed. The tests were performed with the subject positioned in front of the main speaker, at a distance of 2.5 m. Another two speakers were positioned at 3.50 m. The main speaker at 65 dB issued disyllabic words. Babble noise signal was delivered through the other speakers, with variable intensity. The use of both wireless remote microphones improved the SRT results. Both systems improved gain of speech performances. The gain was higher with the Mini Mic system (SRT = -4.76) than the Roger system (SRT = -3.01). The addition of the NR algorithm did not statistically further improve the results. There is significant improvement in speech recognition results with both wireless digital remote microphone accessories, in particular with the Mini Mic system when used with the CP910 processor. The use of a remote microphone accessory surpasses the benefit of application of NR algorithm. Copyright © 2017. Published by Elsevier B.V.
3D printed disposable optics and lab-on-a-chip devices for chemical sensing with cell phones
NASA Astrophysics Data System (ADS)
Comina, G.; Suska, A.; Filippini, D.
2017-02-01
Digital manufacturing (DM) offers fast prototyping capabilities and great versatility to configure countless architectures at affordable development costs. Autonomous lab-on-a-chip (LOC) devices, conceived as only disposable accessory to interface chemical sensing to cell phones, require specific features that can be achieved using DM techniques. Here we describe stereo-lithography 3D printing (SLA) of optical components and unibody-LOC (ULOC) devices using consumer grade printers. ULOC devices integrate actuation in the form of check-valves and finger pumps, as well as the calibration range required for quantitative detection. Coupling to phone camera readout depends on the detection approach, and includes different types of optical components. Optical surfaces can be locally configured with a simple polishing-free post-processing step, and the representative costs are 0.5 US$/device, same as ULOC devices, both involving fabrication times of about 20 min.
Temereva, Elena N; Kuzmina, Tatyana V
2017-07-31
The nervous system in brachiopods has seldom been studied with modern methods. An understanding of lophophore innervation in adult brachiopods is useful for comparing the innervation of the same lophophore type among different brachiopods and can also help answer questions about the monophyly of the lophophorates. Although some brachiopods are studied with modern methods, rhynchonelliform brachiopods still require investigation. The current study used transmission electron microscopy, immunocytochemistry, and confocal laser scanning microscopy to investigate the nerve system of the lophophore and tentacles in the rhynchonelliform Hemithiris psittacea. Four longitudinal nerves pass along each brachium of the lophophore: the main, accessory, second accessory, and lower. The main brachial nerve extends at the base of the dorsal side of the brachial fold and gives rise to the cross nerves, passing through the extracellular matrix to the tentacles. Cross nerves skirt the accessory brachial nerve, branch, and penetrate into adjacent outer and inner tentacles, where they are referred to as the frontal tentacular nerves. The second accessory nerve passes along the base of the inner tentacles. This nerve consists of Ʊ-like parts, which repetitively skirt the frontal and lateral sides of the inner tentacle and the frontal sides of the outer tentacles. The second accessory nerve gives rise to the latero-frontal nerves of the inner and outer tentacles. The abfrontal nerves of the inner tentacles also originate from the second accessory nerve, whereas the abfrontal nerves of the outer tentacles originate from the lower brachial nerve. The lower brachial nerve extends along the outer side of the lophophore brachia and gives rise to the intertentacular nerves, which form a T-like branch and penetrate the adjacent outer tentacles where they are referred to as abfrontal nerves. The paired outer radial nerves start from the lower brachial nerve, extend into the second accessory nerve, and give rise to the lateroabfrontal tentacular nerves of the outer tentacles. The innervation of the lophophore in the rhynchonelliform Hemithiris psittacea differs from that in the inarticulate Lingula anatina in several ways. The accessory brachial nerve does not participate in the innervation of the tentacles in H. psittacea as it does in L. anatina. The second accessory nerve is present in H. psittacea but not in L. anatina. There are six tentacular nerves in the outer tentacles of H. psittacea but only four in all other brachiopods studied to date. The reduced contribution of the accessory brachial nerve to tentacle innervation may reflect the general pattern of reduction of the inner lophophoral nerve in both phoronids and brachiopods. Bryozoan lophophores, in contrast, have a weakened outer nerve and a strengthened inner nerve. Our results suggest that the ancestral lophophore of all lophophorates had a simple shape but many nerve elements.
Reliable sex and strain discrimination in the mouse vomeronasal organ and accessory olfactory bulb.
Tolokh, Illya I; Fu, Xiaoyan; Holy, Timothy E
2013-08-21
Animals modulate their courtship and territorial behaviors in response to olfactory cues produced by other animals. In rodents, detecting these cues is the primary role of the accessory olfactory system (AOS). We sought to systematically investigate the natural stimulus coding logic and robustness in neurons of the first two stages of accessory olfactory processing, the vomeronasal organ (VNO) and accessory olfactory bulb (AOB). We show that firing rate responses of just a few well-chosen mouse VNO or AOB neurons can be used to reliably encode both sex and strain of other mice from cues contained in urine. Additionally, we show that this population code can generalize to new concentrations of stimuli and appears to represent stimulus identity in terms of diverging paths in coding space. Together, the results indicate that firing rate code on the temporal order of seconds is sufficient for accurate classification of pheromonal patterns at different concentrations and may be used by AOS neural circuitry to discriminate among naturally occurring urine stimuli.
NASA Astrophysics Data System (ADS)
Anishkumar, A. R.; Sreejaya, P.
2016-12-01
Kerala is a state in India having a very good potential for solar PV energy production. The domestic customers in Kerala using PV system are approximately 15 % and almost all of them are using the off-grid PV system. When these off grid customers move to on-grid system, off grid system accessories such as inverter and batteries become redundant. In this paper, a switching logic has been developed for the effective utilization of off grid accessories and reducing islanding power loss for on grid customers. An algorithm is proposed for the switching logic and it is verified using simulation results and hardware implementation.
Muroi, Yoshikage; Nishimura, Masakazu; Ishii, Toshiaki
2017-10-31
Odors in female mice induce sexual arousal in male mice. Repeated exposure to female odors attenuates male attraction, which recovers when the odors are removed. The neuronal mechanisms for the recovery of male attraction have not been clarified. In this study, we examined how olfactory systems are involved in the recovery of male attraction to female odors following habituation in mice. Presentation with volatile female odors for 5 min induced habituation in males. To evaluate male attraction to familiar volatile female odors, we measured the duration for investigating volatile female odors from the same female mouse, which was presented twice for 5 min with 1-, 3-, or 5-min interval. Intranasal irrigation with ZnSO4 solution almost completely suppressed investigating behavior, indicating that the main olfactory system is indispensable for inducing the attraction to volatile female odors. In contrast, removal of the vomeronasal organ, bilateral lesions of the accessory olfactory bulb (AOB), or pharmacological blockage of neurotransmission in the AOB did not affect the investigation time at the first odor presentation. However, each one of the treatments decreased the investigation time in the second presentation, compared to that in the first presentation, at longer intervals than control treatment, indicating that the disturbance of neurotransmission in the accessory olfactory system delayed the recovery of the attraction attenuated by the first presentation. These results suggest that the accessory olfactory system facilitates the recovery of the attraction to familiar volatile female odors in male mice. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Multi-microphone adaptive array augmented with visual cueing.
Gibson, Paul L; Hedin, Dan S; Davies-Venn, Evelyn E; Nelson, Peggy; Kramer, Kevin
2012-01-01
We present the development of an audiovisual array that enables hearing aid users to converse with multiple speakers in reverberant environments with significant speech babble noise where their hearing aids do not function well. The system concept consists of a smartphone, a smartphone accessory, and a smartphone software application. The smartphone accessory concept is a multi-microphone audiovisual array in a form factor that allows attachment to the back of the smartphone. The accessory will also contain a lower power radio by which it can transmit audio signals to compatible hearing aids. The smartphone software application concept will use the smartphone's built in camera to acquire images and perform real-time face detection using the built-in face detection support of the smartphone. The audiovisual beamforming algorithm uses the location of talking targets to improve the signal to noise ratio and consequently improve the user's speech intelligibility. Since the proposed array system leverages a handheld consumer electronic device, it will be portable and low cost. A PC based experimental system was developed to demonstrate the feasibility of an audiovisual multi-microphone array and these results are presented.
Phylogenetic Distribution of CRISPR-Cas Systems in Antibiotic-Resistant Pseudomonas aeruginosa
van Belkum, Alex; Soriaga, Leah B.; LaFave, Matthew C.; Akella, Srividya; Veyrieras, Jean-Baptiste; Barbu, E. Magda; Shortridge, Dee; Blanc, Bernadette; Hannum, Gregory; Zambardi, Gilles; Miller, Kristofer; Enright, Mark C.; Mugnier, Nathalie; Brami, Daniel; Schicklin, Stéphane; Felderman, Martina; Schwartz, Ariel S.; Richardson, Toby H.; Peterson, Todd C.; Hubby, Bolyn
2015-01-01
ABSTRACT Pseudomonas aeruginosa is an antibiotic-refractory pathogen with a large genome and extensive genotypic diversity. Historically, P. aeruginosa has been a major model system for understanding the molecular mechanisms underlying type I clustered regularly interspaced short palindromic repeat (CRISPR) and CRISPR-associated protein (CRISPR-Cas)-based bacterial immune system function. However, little information on the phylogenetic distribution and potential role of these CRISPR-Cas systems in molding the P. aeruginosa accessory genome and antibiotic resistance elements is known. Computational approaches were used to identify and characterize CRISPR-Cas systems within 672 genomes, and in the process, we identified a previously unreported and putatively mobile type I-C P. aeruginosa CRISPR-Cas system. Furthermore, genomes harboring noninhibited type I-F and I-E CRISPR-Cas systems were on average ~300 kb smaller than those without a CRISPR-Cas system. In silico analysis demonstrated that the accessory genome (n = 22,036 genes) harbored the majority of identified CRISPR-Cas targets. We also assembled a global spacer library that aided the identification of difficult-to-characterize mobile genetic elements within next-generation sequencing (NGS) data and allowed CRISPR typing of a majority of P. aeruginosa strains. In summary, our analysis demonstrated that CRISPR-Cas systems play an important role in shaping the accessory genomes of globally distributed P. aeruginosa isolates. PMID:26604259
VonAchen, Paige; Hamann, Jason; Houghland, Thomas; Lesser, John R; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F; Daniels, Mary; Schwartz, Robert S
The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p=0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p=0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p=0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in future clinical trials may improve RDN therapeutic efficacy. Copyright © 2016 Elsevier Inc. All rights reserved.
Modeling learning in brain stem and cerebellar sites responsible for VOR plasticity
NASA Technical Reports Server (NTRS)
Quinn, K. J.; Didier, A. J.; Baker, J. F.; Peterson, B. W.
1998-01-01
A simple model of vestibuloocular reflex (VOR) function was used to analyze several hypotheses currently held concerning the characteristics of VOR plasticity. The network included a direct vestibular pathway and an indirect path via the cerebellum. An optimization analysis of this model suggests that regulation of brain stem sites is critical for the proper modification of VOR gain. A more physiologically plausible learning rule was also applied to this network. Analysis of these simulation results suggests that the preferred error correction signal controlling gain modification of the VOR is the direct output of the accessory optic system (AOS) to the vestibular nuclei vs. a signal relayed through the cerebellum via floccular Purkinje cells. The potential anatomical and physiological basis for this conclusion is discussed, in relation to our current understanding of the latency of the adapted VOR response.
Human pheromones and sexual attraction.
Grammer, Karl; Fink, Bernhard; Neave, Nick
2005-02-01
Olfactory communication is very common amongst animals, and since the discovery of an accessory olfactory system in humans, possible human olfactory communication has gained considerable scientific interest. The importance of the human sense of smell has by far been underestimated in the past. Humans and other primates have been regarded as primarily 'optical animals' with highly developed powers of vision but a relatively undeveloped sense of smell. In recent years this assumption has undergone major revision. Several studies indicate that humans indeed seem to use olfactory communication and are even able to produce and perceive certain pheromones; recent studies have found that pheromones may play an important role in the behavioural and reproduction biology of humans. In this article we review the present evidence of the effect of human pheromones and discuss the role of olfactory cues in human sexual behaviour.
21 CFR 878.4350 - Cryosurgical unit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and accessories. (a) Identification—(1) Cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories. A cryosurgical unit with a liquid nitrogen cooled cryoprobe and accessories is a device intended...
A new concept and classification of corona mortis and its clinical significance.
Al Talalwah, Waseem
2016-10-01
The obturator artery and its accessory (aberrant) arising from different origins and crossing the pubic rami are vascular variations. The internal iliac artery usually provides the obturator artery which may communicates with the external iliac artery through either the accessory obturator or inferior epigastric artery. A collateral circulation between the external and internal iliac system is known as corona mortis. The aim of current study is to provide sufficient data of vascular variability crossing the pubic rami for clinical field. Present study includes 208 hemipelvises dissected in the Institution of Anatomy, Medical University of Graz. During dissection, the obturator artery and its accessory crossing the superior rami of pubic bone were found to have different origins. The obturator artery arising from the external iliac artery and from the femoral artery accounts for 9.8% and 1.1% respectively. Therefore, it passes over the superior pubic rami in 10.9%. Further, the accessory (aberrant) artery arises only from the femoral artery in 1.1%. In present study, the vascular variation crossing the superior pubic rami with or without collateral circulation between external and internal iliac system referred as corona mortis is addressed. This study includes new classification of obturator and accessory obturator arteries as well as the corona mortis. It includes a comparison of corona mortis incidence in Austria population and other populations. The corona mortis found to be in 12% of Austrian population. A great attention of clinicians, radiologists, surgeons, orthopedic surgeons, obstetricians and gynecologists has to be considered before pubic surgical procedures such as internal fixation of pubic fracture, an inguinal hernia repair. Further, traumatic pubic rami fracture may lead to massive hemor- rhage due to laceration of the obturator artery.
Gur, Rotem; Tendler, Alex; Wagner, Shlomo
2014-09-01
Recognition of specific individuals is fundamental to mammalian social behavior and is mediated in most mammals by the main and accessory olfactory systems. Both these systems innervate the medial amygdala (MeA), where activity of the neuropeptide oxytocin is thought to mediate social recognition memory (SRM). The specific contribution of the MeA to SRM formation and the specific actions of oxytocin in the MeA are unknown. We used the social discrimination test to evaluate short-term and long-term SRM in adult Sprague-Dawley male rats (n = 38). The role of protein synthesis in the MeA was investigated by local application of the protein synthesis blocker anisomycin (n = 11). Synaptic plasticity was assessed in vivo by recording the MeA evoked field potential responses to stimulation of the main (n = 21) and accessory (n = 56) olfactory bulbs before and after theta burst stimulation. Intracerebroventricular administration of saline, oxytocin, or oxytocin receptor antagonist was used to measure the effect of oxytocin on synaptic plasticity. Anisomycin application to the MeA prevented the formation of long-term SRM. In addition, the responses of MeA neurons underwent long-term depression (LTD) after theta burst stimulation of the accessory olfactory bulb, but not the main accessory bulb, in an oxytocin-dependent manner. No LTD was found in socially isolated rats, which are known to lack long-term SRM. Finally, accessory olfactory bulb stimulation before SRM acquisition blocked long-term SRM, supporting the involvement of LTD in the MeA in formation of long-term SRM. Our results indicate that long-term SRM in rats involves protein synthesis and oxytocin-dependent LTD in the MeA. Copyright © 2014 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Mappes, Martina; Homberg, Uwe
2007-01-01
Many insects can detect the polarization pattern of the blue sky and rely on polarization vision for sky compass orientation. In laboratory experiments, tethered flying locusts perform periodic changes in flight behavior under a slowly rotating polarizer even if one eye is painted black. Anatomical tracing studies and intracellular recordings have suggested that the polarization vision pathway in the locust brain involves the anterior optic tract and tubercle, the lateral accessory lobe, and the central complex of the brain. To investigate whether visual pathways through the anterior optic tract mediate polarotaxis in the desert locust, we transected the tract on one side and tested polarotaxis (1) with both eyes unoccluded and (2) with the eye of the intact hemisphere painted black. In the second group of animals, but not in the first group, polarotaxis was abolished. Sham operations did not impair polarotaxis. The experiments show that the anterior optic tract is an indispensable part of visual pathways mediating polarotaxis in the desert locust.
Karl Otto Himmler, manufacturer of the first contact lens.
Pearson, Richard M
2007-03-01
In 1889 August Müller (1864-1949) reported the correction of his own high myopia with a ground scleral contact lens that had been manufactured in Berlin two years earlier. This paper provides the first conclusive identification, based upon primary sources, of the manufacturer of these lenses. They were made by an optical engineer, Karl Otto Himmler (1841-1903), whose firm enjoyed, until the outbreak of World War II, an international reputation for the manufacture of microscopes and their accessories.
The revised anatomy of the canals connecting the orbit with the cranial cavity.
Regoli, Marì; Bertelli, Eugenio
2017-04-01
Orbits are connected with the middle cranial fossa via the optic canal, the superior orbital fissure, the M-type orbitomeningeal foramen, the metoptic canal, an accessory anterior opening of the foramen rotundum, and Warwick's canal. They are also in communication with the anterior cranial fossa via the ethmoidal canals and the A-type orbitomeningeal foramen. The anatomy of these conduits has been recently enriched with several details that are summarized and reviewed in this article.
Artz, Jacob H; Mulder, David W; Ratzloff, Michael W; Lubner, Carolyn E; Zadvornyy, Oleg A; LeVan, Axl X; Williams, S Garrett; Adams, Michael W W; Jones, Anne K; King, Paul W; Peters, John W
2017-07-19
An [FeFe]-hydrogenase from Clostridium pasteurianum, CpI, is a model system for biological H 2 activation. In addition to the catalytic H-cluster, CpI contains four accessory iron-sulfur [FeS] clusters in a branched series that transfer electrons to and from the active site. In this work, potentiometric titrations have been employed in combination with electron paramagnetic resonance (EPR) spectroscopy at defined electrochemical potentials to gain insights into the role of the accessory clusters in catalysis. EPR spectra collected over a range of potentials were deconvoluted into individual components attributable to the accessory [FeS] clusters and the active site H-cluster, and reduction potentials for each cluster were determined. The data suggest a large degree of magnetic coupling between the clusters. The distal [4Fe-4S] cluster is shown to have a lower reduction potential (∼ < -450 mV) than the other clusters, and molecular docking experiments indicate that the physiological electron donor, ferredoxin (Fd), most favorably interacts with this cluster. The low reduction potential of the distal [4Fe-4S] cluster thermodynamically restricts the Fd ox /Fd red ratio at which CpI can operate, consistent with the role of CpI in recycling Fd red that accumulates during fermentation. Subsequent electron transfer through the additional accessory [FeS] clusters to the H-cluster is thermodynamically favorable.
Accessory wandering spleen: Report of a case of laparoscopic approach in an asymptomatic patient
Perin, Alessandro; Cola, Roberto; Favretti, Franco
2014-01-01
INTRODUCTION Accessory wandering spleen is a rare but dangerous condition. Abnormalities of the ligamentous apparatus of an accessory spleen may evolve into torsion of its vascular axis, which can lead to a splenic infarct making surgery necessary. Patients are often asymptomatic and the diagnosis can be accidental. An early diagnosis and a correct treatment are fundamental. PRESENTATION OF CASE In this case report a young woman underwent laparoscopic surgery after an incidental finding at a Pelvic Ultrasound of an accessory wandering spleen. DISCUSSION In literature are reported cases of asymptomatic patients with an accessory wandering spleen treated with a conservative approach. However, a torsion or infarct of the accessory wandering spleen leads to emergency surgery. The presence of an independent vascular axis of the accessory spleen reduces the risk of postoperative complications (e.g. thrombocytosis) and the administration of low molecular weight heparin should prevent the risk of portal thrombosis. CONCLUSION We suggest performing surgery with a laparoscopic approach in patients with accessory wandering spleen, though asymptomatic, because of the risk of serious complications in case of accessory spleen torsion. PMID:25460427
Zhu, Yizheng; Terry, Neil G; Wax, Adam
2012-01-01
Angle-resolved low-coherence interferometry (a/LCI) is an optical biopsy technique that measures scattered light from tissue to determine nuclear size with submicron-level accuracy. The a/LCI probe can be deployed through the accessory channel of a standard endoscope and provides feedback to physicians to guide physical biopsies. The technique has been validated in animal and ex vivo human studies, and has been used to detect dysplasia in Barrett’s esophagus patients in vivo. In a recent clinical study of 46 Barrett’s esophagus patients, a/LCI was able to detect dysplasia with 100% sensitivity and 84% specificity. This report reviews the technique and discusses its potential clinical utility. PMID:22149580
Algal Accessory Pigment Detection Using AVIRIS Image-Derived Spectral Radiance Data
NASA Technical Reports Server (NTRS)
Richardson, Laurie L.; Ambrosia, Vincent G.
1996-01-01
Visual and derivative analyses of AVIRIS spectral data can be used to detect algal accessory pigments in aquatic communities. This capability extends the use of remote sensing for the study of aquatic ecosystems by allowing detection of taxonomically significant pigment signatures which yield information about the type of algae present. Such information allows remote sensing-based assessment of aquatic ecosystem health, as in the detection of nuisance blooms of cyanobacteria or toxic blooms of dinoflagellates. Remote sensing of aquatic systems has traditionally focused on quantification of chlorophyll a, a photoreactive (and light-harvesting) pigment which is common to all algae as well as cyanobacteria (bluegreen algae). Due to the ubiquitousness of this pigment within algae, chl a is routinely measured to estimate algal biomass both during ground-truthing and using various airborne or satellite based sensors, including AVIRIS. Within the remote sensing and aquatic sciences communities, ongoing research has been performed to detect algal accessory pigments for assessment of algal population composition. This research is based on the fact that many algal accessory pigments are taxonomically significant, and all are spectrally unique. Aquatic scientists have been refining pigment analysis techniques, primarily high performance liquid chromatography, or HPLC, to detect specific pigments as a time-saving alternative to individual algal cell identifications and counts. Remote sensing scientists are investigating the use of pigment signatures to construct pigment libraries analogous to mineral spectral libraries used in geological remote sensing applications. The accessory pigment approach has been used successfully in remote sensing using data from the Thematic Mapper, low-altitude, multiple channel scanners, field spectroradiometers and the AVIRIS hyperspectral scanner. Due to spectral and spatial resolution capabilities, AVIRIS is the sensor of choice for such studies. We present here our results on detection of algal accessory pigments using AVIRIS data.
21 CFR 872.3980 - Endosseous dental implant accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...
21 CFR 872.3980 - Endosseous dental implant accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...
21 CFR 872.3980 - Endosseous dental implant accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...
21 CFR 872.3980 - Endosseous dental implant accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...
21 CFR 872.3980 - Endosseous dental implant accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...
Laranjo, Sérgio; Oliveira, Mário; Trigo, Conceição
2015-08-01
Left anterior accessory pathways are considered to be rare findings. Catheter ablation of accessory pathways in this location remains a challenging target, and few reports about successful ablation of these accessory pathways are available. We describe our experience regarding a case of a manifest left anterior accessory pathway ablation using radiofrequency energy at the junction of the left coronary cusp with the non-coronary cusp.
Walker, Michael J; Rylett, Caroline M; Keen, Jeff N; Audsley, Neil; Sajid, Mohammed; Shirras, Alan D; Isaac, R Elwyn
2006-05-02
In Drosophila melanogaster, the male seminal fluid contains proteins that are important for reproductive success. Many of these proteins are synthesised by the male accessory glands and are secreted into the accessory gland lumen, where they are stored until required. Previous studies on the identification of Drosophila accessory gland products have largely focused on characterisation of male-specific accessory gland cDNAs from D. melanogaster and, more recently, Drosophila simulans. In the present study, we have used a proteomics approach without any sex bias to identify proteins in D. melanogaster accessory gland secretions. Thirteen secreted accessory gland proteins, including seven new accessory gland proteins, were identified by 2D-gel electrophoresis combined with mass spectrometry of tryptic fragments. They included protein-folding and stress-response proteins, a hormone, a lipase, a serpin, a cysteine-rich protein and two peptidases, a pro-enzyme form of a cathepsin K-like cysteine peptidase and a gamma-glutamyl transpeptidase. Enzymatic studies established that accessory gland secretions contain a cysteine peptidase zymogen that can be activated at low pH. This peptidase may have a role in the processing of female and other male-derived proteins, but is unlikely to be involved in the processing of the sex peptide. gamma-Glutamyl transpeptidases are type II integral membrane proteins; however, the identified AG gamma-glutamyl transpeptidase (GGT-1) is unusual in that it is predicted to be a soluble secreted protein, a prediction that is supported by biochemical evidence. GGT-1 is possibly involved in maintaining a protective redox environment for sperm. The strong gamma-glutamyl transpeptidase activity found in the secretions provides an explanation for the observation that glutamic acid is the most abundant free amino acid in accessory gland secretions of D. melanogaster. We have applied biochemical approaches, not used previously, to characterise prominent D. melanogaster accessory gland products. Of the thirteen accessory gland secreted proteins reported in this study, six were represented in a D. simulans male accessory gland EST library that was biased for male-specific genes. Therefore, the present study has identified seven new secreted accessory gland proteins, including GGT-1, which was not recognised previously as a secreted accessory gland product.
21 CFR 876.5250 - Urine collector and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...
21 CFR 876.5250 - Urine collector and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...
21 CFR 876.5250 - Urine collector and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...
21 CFR 876.5250 - Urine collector and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...
21 CFR 876.5250 - Urine collector and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine collector and accessories. 876.5250 Section... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine collector and accessories. (a) Identification. A urine collector and accessories is a device intended to collect...
21 CFR 872.4920 - Dental electrosurgical unit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...
21 CFR 872.4920 - Dental electrosurgical unit and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...
21 CFR 872.4920 - Dental electrosurgical unit and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...
21 CFR 872.4920 - Dental electrosurgical unit and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...
21 CFR 872.4920 - Dental electrosurgical unit and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an AC-powered...
21 CFR 868.5860 - Pressure tubing and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended to...
Future Development of Endoscopic Accessories for Endoscopic Submucosal Dissection
Jang, Jae-Young
2017-01-01
Endoscopic submucosal dissection (ESD) has recently been accepted as a standard treatment for patients with early gastric cancer (EGC), without lymph node metastases. Given the rise in the number of ESDs being performed, new endoscopic accessories are being developed and existing accessories modified to facilitate the execution of ESD and reduce complication rates. This paper examines the history underlying the development of these new endoscopic accessories and indicates future directions for the development of these accessories. PMID:28609819
21 CFR 872.4120 - Bone cutting instrument and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...
21 CFR 872.4120 - Bone cutting instrument and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...
21 CFR 872.4120 - Bone cutting instrument and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...
21 CFR 872.4120 - Bone cutting instrument and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...
21 CFR 872.4120 - Bone cutting instrument and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...
26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of automobile... for the person reassembling the generator, (6) reground or remetalized crankshafts, and (7) engines in... reassembling (with any necessary replacements of worn parts) of automobile parts or accessories, such as fuel...
26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of automobile... for the person reassembling the generator, (6) reground or remetalized crankshafts, and (7) engines in... reassembling (with any necessary replacements of worn parts) of automobile parts or accessories, such as fuel...
26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of automobile... for the person reassembling the generator, (6) reground or remetalized crankshafts, and (7) engines in... reassembling (with any necessary replacements of worn parts) of automobile parts or accessories, such as fuel...
21 CFR 872.6640 - Dental operative unit and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...
21 CFR 872.6640 - Dental operative unit and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...
21 CFR 872.4200 - Dental handpiece and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...
21 CFR 872.6640 - Dental operative unit and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...
21 CFR 872.4200 - Dental handpiece and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...
21 CFR 872.4200 - Dental handpiece and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...
21 CFR 872.6640 - Dental operative unit and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...
21 CFR 872.4200 - Dental handpiece and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...
21 CFR 872.4200 - Dental handpiece and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven...
21 CFR 872.6640 - Dental operative unit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that is...
21 CFR 876.5900 - Ostomy pouch and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ostomy pouch and accessories. 876.5900 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5900 Ostomy pouch and accessories. (a) Identification. An ostomy pouch and accessories is a device that consists of a bag that is...
21 CFR 878.3925 - Plastic surgery kit and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...
21 CFR 878.3925 - Plastic surgery kit and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...
21 CFR 878.3925 - Plastic surgery kit and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...
21 CFR 878.3925 - Plastic surgery kit and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...
21 CFR 878.3925 - Plastic surgery kit and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...
Advanced Gas Turbine (AGT) powertrain system development for automotive applications
NASA Technical Reports Server (NTRS)
1981-01-01
Compressor development, turbine, combustion, regenerator system, gearbox/transmission, ceramic material and component development, foil gas bearings, bearings and seals, rotor dynamics development, and controls and accessories are discussed.
Rurkhamet, Busagarin; Nanthavanij, Suebsak
2004-12-01
One important factor that leads to the development of musculoskeletal disorders (MSD) and cumulative trauma disorders (CTD) among visual display terminal (VDT) users is their work posture. While operating a VDT, a user's body posture is strongly influenced by the task, VDT workstation settings, and layout of computer accessories. This paper presents an analytic and rule-based decision support tool called EQ-DeX (an ergonomics and quantitative design expert system) that is developed to provide valid and practical recommendations regarding the adjustment of a VDT workstation and the arrangement of computer accessories. The paper explains the structure and components of EQ-DeX, input data, rules, and adjustment and arrangement algorithms. From input information such as gender, age, body height, task, etc., EQ-DeX uses analytic and rule-based algorithms to estimate quantitative settings of a computer table and a chair, as well as locations of computer accessories such as monitor, document holder, keyboard, and mouse. With the input and output screens that are designed using the concept of usability, the interactions between the user and EQ-DeX are convenient. Examples are also presented to demonstrate the recommendations generated by EQ-DeX.
Laothanachareon, Thanaporn; Bunterngsook, Benjarat; Suwannarangsee, Surisa; Eurwilaichitr, Lily; Champreda, Verawat
2015-12-01
Synergism between core cellulases and accessory hydrolytic/non-hydrolytic enzymes is the basis of efficient hydrolysis of lignocelluloses. In this study, the synergistic action of three recombinant accessory enzymes, namely GH62 α-l-arabinofuranosidase (ARA), CE8 pectin esterase (PET), and GH10 endo-1,4-beta-xylanase (XYL) from Aspergillus aculeatus expressed in Pichia pastoris to a commercial Trichoderma reesei cellulase (Accellerase® 1500; ACR) on hydrolysis of alkaline pretreated rice straw was studied using a mixture design approach. Applying the full cubic model, the optimal ratio of quaternary enzyme mixture was predicted to be ACR:ARA:PET:XYL of 0.171:0.079:0.100:0.150, which showed a glucose releasing efficiency of 0.173 gglc/FPU, higher than the binary ACR:XYL mixture (0.122 gglc/FPU) and ACR alone (0.081 gglc/FPU) leading to a 47.3% increase in glucose yield compared with that from ACR at the same cellulase dosage. The result demonstrates the varying degree of synergism of accessory enzymes to cellulases useful for developing tailor-made enzyme systems for bio-industry. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mammotome-Assisted Liposuction: A Novel Technique for Accessory Breasts.
Tang, Xin
2017-06-01
Due to its minimally invasive and highly precise nature, the mammotome, a vacuum-assisted breast biopsy device, has proven effective for the treatment of benign breast lesions. Taking advantage of both liposuction and the mammotome, we utilized the mammotome device for the excision of accessory breasts. Between July 2010 and June 2014, 16 patients with accessory breasts received mammotome-assisted liposuction. After adipose was removed using this procedure, the mammotome system was used to excise the fibro-glandular tissue in accessory breasts under ultrasound monitoring. All patients were satisfied with their appearance after surgery. A single 5-mm incision, which was well hidden in the axillary skin folds and allowed for restoration, provided an aesthetically pleasing contour to the axilla. Mammotome-assisted liposuction is a new approach that can be used to excise both adipose and fibro-glandular breast tissue simultaneously with a minimal incision, and provides a favorable contour to the axilla. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artz, Jacob H.; Mulder, David W.; Ratzloff, Michael W.
An [FeFe]-hydrogenase from Clostridium pasteurianum, CpI, is a model system for biological H 2 activation. In addition to the catalytic H-cluster, CpI contains four accessory iron-sulfur [FeS] clusters in a branched series that transfer electrons to and from the active site. In this work, potentiometric titrations have been employed in combination with electron paramagnetic resonance (EPR) spectroscopy at defined electrochemical potentials to gain insights into the role of the accessory clusters in catalysis. EPR spectra collected over a range of potentials were deconvoluted into individual components attributable to the accessory [FeS] clusters and the active site H-cluster, and reduction potentialsmore » for each cluster were determined. The data suggest a large degree of magnetic coupling between the clusters. The distal [4Fe-4S] cluster is shown to have a lower reduction potential (~ < -450 mV) than the other clusters, and molecular docking experiments indicate that the physiological electron donor, ferredoxin (Fd), most favorably interacts with this cluster. The low reduction potential of the distal [4Fe-4S] cluster thermodynamically restricts the Fd ox/Fd red ratio at which CpI can operate, consistent with the role of CpI in recycling Fd redthat accumulates during fermentation. In conclusion, subsequent electron transfer through the additional accessory [FeS] clusters to the H-cluster is thermodynamically favorable.« less
Artz, Jacob H.; Mulder, David W.; Ratzloff, Michael W.; ...
2017-06-21
An [FeFe]-hydrogenase from Clostridium pasteurianum, CpI, is a model system for biological H 2 activation. In addition to the catalytic H-cluster, CpI contains four accessory iron-sulfur [FeS] clusters in a branched series that transfer electrons to and from the active site. In this work, potentiometric titrations have been employed in combination with electron paramagnetic resonance (EPR) spectroscopy at defined electrochemical potentials to gain insights into the role of the accessory clusters in catalysis. EPR spectra collected over a range of potentials were deconvoluted into individual components attributable to the accessory [FeS] clusters and the active site H-cluster, and reduction potentialsmore » for each cluster were determined. The data suggest a large degree of magnetic coupling between the clusters. The distal [4Fe-4S] cluster is shown to have a lower reduction potential (~ < -450 mV) than the other clusters, and molecular docking experiments indicate that the physiological electron donor, ferredoxin (Fd), most favorably interacts with this cluster. The low reduction potential of the distal [4Fe-4S] cluster thermodynamically restricts the Fd ox/Fd red ratio at which CpI can operate, consistent with the role of CpI in recycling Fd redthat accumulates during fermentation. In conclusion, subsequent electron transfer through the additional accessory [FeS] clusters to the H-cluster is thermodynamically favorable.« less
21 CFR 884.6120 - Assisted reproduction accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... II (special controls) (design specifications, labeling requirements, and clinical testing). ... Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group of...
21 CFR 884.6120 - Assisted reproduction accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... II (special controls) (design specifications, labeling requirements, and clinical testing). ... Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group of...
21 CFR 884.6120 - Assisted reproduction accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... II (special controls) (design specifications, labeling requirements, and clinical testing). ... Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group of...
21 CFR 872.6250 - Dental chair and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...
21 CFR 872.6250 - Dental chair and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...
21 CFR 872.6250 - Dental chair and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...
21 CFR 872.6250 - Dental chair and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...
21 CFR 872.6250 - Dental chair and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits. The...
19 CFR 10.537 - Accessories, spare parts, or tools.
Code of Federal Regulations, 2010 CFR
2010-04-01
... parts, or tools will be taken into account as originating or non-originating materials, as the case may... 19 Customs Duties 1 2010-04-01 2010-04-01 false Accessories, spare parts, or tools. 10.537 Section... Free Trade Agreement Rules of Origin § 10.537 Accessories, spare parts, or tools. Accessories, spare...
21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...
21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...
21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...
21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...
21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical...
Accessory mental foramina and nerves: Application to periodontal, periapical, and implant surgery.
Iwanaga, Joe; Watanabe, Koichi; Saga, Tsuyoshi; Tabira, Yoko; Kitashima, Sadaharu; Kusukawa, Jingo; Yamaki, Koh-Ichi
2016-05-01
Recent studies investigating accessory mental foramina using developments in diagnostic imaging have primarily defined the morphology of the foramina; however, few studies have described the structures passing through them. Additional clinical knowledge of the foramina is therefore required for preoperative diagnosis prior to surgery, including implant, periodontal and periapical surgery. In this study, we investigated the accessory mental foramina and the associated nerves and arteries in donated cadaveric mandibles using anatomical and radiological observation methods. We examined 63 mandibles with overlying soft tissue by cone-beam computed tomography and noted the existence of the accessory mental foramina. Mandibles with accessory mental foramina were subsequently analyzed. Additionally, the neurovascular bundles passing through these foramina were dissected using anatomical methods.The incidence of accessory mental foramina was 14.3%. The larger foramina tended to be located anteriorly or superiorly and proximal to the mental foramen, while the smaller foramina tended to be located posterosuperiorly and distal to the mental foramen. The mental foramen ipsilateral to the accessory mental foramen was smaller than the one contralateral to it. The comparatively distant and large accessory mental foramen included an artery.This study elucidated the relationship between accessory mental foramina and the associated nerves and arteries. We believe that the results will contribute to the clinical dentistry field. © 2015 Wiley Periodicals, Inc.
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
Neethling, Lourelle Alicia Martins; Avenant-Oldewage, Annemariè
2015-02-01
The morphology of the male reproductive system as well as sperm transfer in Branchiura has been described for Dolops ranarum and Argulus japonicus. In this study, the reproductive system and accessory structures are described for male Chonopeltis australis using histology, light microscopy, and scanning electron microscopy. For the first time, we describe sperm transfer by means of a spermatophore in this genus. The internal and external morphology and mechanism of sperm transfer is compared with other Branchiura, where it has been described. The morphology of the reproductive system of C. australis is similar to that of D. ranarum while the accessory structures and the spermatophore produced are similar to that of A. japonicus. A revision of the definition of Branchiura with respect to reproduction is provided. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Comin-Chiaramonti, Piero; Renzulli, Alberto; Ridolfi, Filippo; Enrich, Gaston E. R.; Gomes, Celso B.; De Min, Angelo; Azzone, Rogério G.; Ruberti, Excelso
2016-11-01
This work describes rare accessory minerals in volcanic and subvolcanic silica-undersaturated peralkaline and agpaitic rocks from the Permo-Triassic Cerro Boggiani complex (Eastern Paraguay) in the Alto Paraguay Alkaline Province. These accessory phases consist of various minerals including Th-U oxides/silicates, Nb-oxide, REE-Sr-Ba bearing carbonates-fluorcarbonates-phosphates-silicates and Zr-Na rich silicates. They form a late-stage magmatic to deuteric/metasomatic assemblage in agpaitic nepheline syenites and phonolite dykes/lava flows made of sodalite, analcime, albite, fluorite, calcite, ilmenite-pyrophanite, titanite and zircon. It is inferred that carbonatitic fluids rich in F, Na and REE percolated into the subvolcanic system and metasomatically interacted with the Cerro Boggiani peralkaline and agpaitic silicate melts at the thermal boundary layers of the magma chamber, during and shortly after their late-stage magmatic crystallization and hydrothermal deuteric alteration.
21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
2017-08-01
accessories for mounting e. Laser power supply f. TEC power supply 12. Optical filters from SEMROCK ®, THORLABS Inc., EDMUND OPTICS® a. 532-nm, laser...line filter ( SEMROCK ®) b. 550-nm, hard-coated, short-pass filter (THORLABS Inc.) c. 532-nm long-pass filter ( SEMROCK ®) d. 808-nm laser-line filter... SEMROCK ®) e. 850-nm /10-nm full width at half maximum (FWHM) bandpass filter ( SEMROCK ®) f. 980-nm bandpass filter ( SEMROCK ®) g. 976-nm laser-line
Li, Xiaochun; Yang, Fan; Wong, Jessica X H; Yu, Hua-Zhong
2017-09-05
We demonstrate herein an integrated, smartphone-app-chip (SPAC) system for on-site quantitation of food toxins, as demonstrated with aflatoxin B1 (AFB1), at parts-per-billion (ppb) level in food products. The detection is based on an indirect competitive immunoassay fabricated on a transparent plastic chip with the assistance of a microfluidic channel plate. A 3D-printed optical accessory attached to a smartphone is adapted to align the assay chip and to provide uniform illumination for imaging, with which high-quality images of the assay chip are captured by the smartphone camera and directly processed using a custom-developed Android app. The performance of this smartphone-based detection system was tested using both spiked and moldy corn samples; consistent results with conventional enzyme-linked immunosorbent assay (ELISA) kits were obtained. The achieved detection limit (3 ± 1 ppb, equivalent to μg/kg) and dynamic response range (0.5-250 ppb) meet the requested testing standards set by authorities in China and North America. We envision that the integrated SPAC system promises to be a simple and accurate method of food toxin quantitation, bringing much benefit for rapid on-site screening.
14 CFR 23.1165 - Engine ignition systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Controls and Accessories § 23.1165 Engine ignition systems. (a) Each battery ignition system must be... ignition. (e) Each turbine engine ignition system must be independent of any electrical circuit that is not... commuter category airplanes, each turbine engine ignition system must be an essential electrical load. [Doc...
14 CFR 23.1165 - Engine ignition systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Controls and Accessories § 23.1165 Engine ignition systems. Link to an amendment published at 76 FR 75759... discharge of any battery used for engine ignition. (e) Each turbine engine ignition system must be... ignition systems. (f) In addition, for commuter category airplanes, each turbine engine ignition system...
Os tibiale externum or sesamoid in the tendon of tibialis posterior.
Bareither, D J; Muehleman, C M; Feldman, N J
1995-01-01
From a total of 165 foot and lower leg cadaveric specimens, 38 specimens were selected by palpation of the region of the tuberosity of the navicular for the possible presence of an accessory bone. Specimens were radiographed and dissected to reveal the presence of an accessory bone and its relationship to the tibialis posterior tendon. Nineteen of the specimens exhibited hypertrophy of the tibialis posterior tendon and 19 specimens exhibited an accessory bone. Specimens exhibiting an accessory bone were divided into two categories. In one group, the accessory bone was located in the tibialis posterior tendon prior to its division and was separated from the tuberosity by at least 3 mm. In the other group, the accessory bone was located in the main segment of the tibialis posterior tendon, connected to the tuberosity of the navicular by fibrous tissue, and, in some cases, exhibited a central cavity between the accessory bone and tuberosity. The accessory bone of specimens in the first group was considered to be a sesamoid in the tibialis posterior tendon and the accessory bone in the second group was an ossicle considered to be the os tibiale externum. Linking the os tibiale externum to the tibiale component of the primitive tetrapod foot rather than to the prehallux component eliminates the use of the term "prehallux" as an alternative name for this ossicle.
21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., pulleys, or weights, and that is intended to apply a therapeutic pulling force to the skeletal system. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...
21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., pulleys, or weights, and that is intended to apply a therapeutic pulling force to the skeletal system. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...
21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., pulleys, or weights, and that is intended to apply a therapeutic pulling force to the skeletal system. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...
21 CFR 876.5870 - Sorbent hemoperfusion system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... system. (a) Identification. A sorbent hemoperfusion system is a device that consists of an extracorporeal blood system similar to that identified in the hemodialysis system and accessories (§ 876.5820) and a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sorbent hemoperfusion system. 876.5870 Section 876...
14 CFR 25.1161 - Fuel jettisoning system controls.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel jettisoning system controls. 25.1161... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Controls and Accessories § 25.1161 Fuel jettisoning system controls. Each fuel jettisoning system control must have guards...
14 CFR 25.1161 - Fuel jettisoning system controls.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel jettisoning system controls. 25.1161... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Controls and Accessories § 25.1161 Fuel jettisoning system controls. Each fuel jettisoning system control must have guards...
14 CFR 25.1161 - Fuel jettisoning system controls.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel jettisoning system controls. 25.1161... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Controls and Accessories § 25.1161 Fuel jettisoning system controls. Each fuel jettisoning system control must have guards...
14 CFR 25.1161 - Fuel jettisoning system controls.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel jettisoning system controls. 25.1161... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Controls and Accessories § 25.1161 Fuel jettisoning system controls. Each fuel jettisoning system control must have guards...
14 CFR 25.1161 - Fuel jettisoning system controls.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel jettisoning system controls. 25.1161... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Powerplant Controls and Accessories § 25.1161 Fuel jettisoning system controls. Each fuel jettisoning system control must have guards...
21 CFR 892.5650 - Manual radionuclide applicator system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...
21 CFR 892.5650 - Manual radionuclide applicator system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...
21 CFR 892.5650 - Manual radionuclide applicator system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...
21 CFR 892.5650 - Manual radionuclide applicator system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...
21 CFR 892.5650 - Manual radionuclide applicator system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual radionuclide applicator system. 892.5650... planning computer programs, and accessories. (b) Classification. Class I (general controls). The device is...
Li, Xiaozhong; Shi, Lenian; Liu, Taiyun; Wang, Lin
2012-01-01
Summary Sesamoid bones and accessory ossicles are research focuses of foot and ankle surgery. Pains of the foot and ankle are related to sesamoid bones and accessory ossicles. The specific anatomical and functional relationship of sesamoid bones and accessory ossicles can cause such bone diseases as the dislocation of sesamoid bones and accessory bones, infection, inflammation and necrosis of sesamoid bones, cartilage softening, tenosynovitis of sesamoid bones and the sesamoid bone syndrome. However, these bone diseases are often misdiagnosed or mistreated. In patients with trauma history, relevant diseases of sesamoid bones and accessory ossicles as above mentioned are highly probable to be misdiagnosed as avulsion fractures. In such cases, radiographic findings may provide a basis for clinical diagnosis. PMID:25343083
NASA Astrophysics Data System (ADS)
Desai, Ashvin
1988-09-01
Wandering through the exhibit hall yesterday, I noticed that if you look at the laser companies and if you look at the accessory companies, there are pretty much the same number of accessory booths as well as the laser companies. There was one difference. Laser company booths are all sexy looking, very flashy, big booths. Whereas if you look at the accessories booths, they were small, not so prominent.
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
49 CFR 393.209 - Steering wheel systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES...) Steering column. The steering column must be securely fastened. (d) Steering system. Universal joints and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Definitions. 713.101 Section 713.101 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION PROCEDURES General 713.101 Definitions. Accessorial...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Definitions. 713.101 Section 713.101 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION PROCEDURES General 713.101 Definitions. Accessorial...
46 CFR 182.458 - Portable fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used...
46 CFR 182.458 - Portable fuel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used...
46 CFR 182.458 - Portable fuel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used...
Cooling Tests of an Airplane Equipped with an NACA Cowling and a Wing-duct Cooling System
NASA Technical Reports Server (NTRS)
Turner, L I , Jr; Bierman, David; Boothy, W B
1941-01-01
Cooling tests were made of a Northrop A-17A attack airplane successively equipped with a conventional.NACA cowling and with a wing-duct cooling system. The method of cooling the engine by admitting air from the propeller slipstream into wing ducts, passing it first through the accessory compartment and then over the engine from rear to front, appeared to offer possibilities for improved engine cooling, increased cooling of the accessories, and better fairing of the power-plant installation. The results showed that ground cooling for the wing duct system without cowl flap was better than for the NACA cowling with flap; ground cooling was appreciably improved by installing a cowl flap. Satisfactory temperatures were maintained in both climb and high-speed flight, but, with the use of conventional baffles, a greater quantity of cooling air appeared to be required for the wing duct system.
14 CFR 25.1163 - Powerplant accessories.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed to prevent contamination of...
21 CFR 874.4680 - Bronchoscope (flexible or rigid) and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (flexible or rigid) and accessories. (a) Identification. A bronchoscope (flexible or rigid) and accessories... bronchoscope and is intended to examine or treat the larynx and tracheobronchial tree. It is typically used...
NASA Astrophysics Data System (ADS)
Xu, Nuo; Lei, Xue; Yang, Xiaoli; Li, Xinhui; Ge, Zhenlin
2018-04-01
Objective: to compare canine tooth stress distribution condition during maxillary canine tooth distalization by different accessories of bracket-free invisible orthodontics technology after removal of maxillary first premolar, and provide basis for clinical design of invisible orthodontics technology. Method: CBCT scanning image of a patient with individual normal occlusion was adopted, Mimics, Geomagic and ProlE software were used for establishing three-dimensional models of maxilla, maxillary dentition, parodontium, invisible orthodontics appliance and accessories, ANSYS WORKBENCH was utilized as finite element analysis tools for analyzing stress distribution and movement pattern of canine tooth and parodontium when canine tooth was equipped with power arm and vertical rectangle accessory. Meanwhile, canine tooth none-accessory design group was regarded as a control. Result: teeth had even bistal surface stress distribution in the power arm group; stress was concentrated on distal tooth neck, and the stress was gradually deviated to mesial-labial side and distal lingual side in vertical rectangle group and none-accessory group. Conclusion: teeth tend to move as a whole in the Power arm group, vertical rectangle group has lower tooth gradient compared with the none-accessory group, teeth are inclined for movement in the none-accessory group, and canine teeth tend to rotate to the distal lingual side.
14 CFR 29.1163 - Powerplant accessories.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Powerplant accessories. (a) Each engine mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent...
14 CFR 27.1163 - Powerplant accessories.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Powerplant accessories. (a) Each engine-mounted accessory must— (1) Be approved for mounting on the engine involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent...
de Leon-Martinez, Enrique Ponce; Garza, Javier A; Azpiri-Lopez, Jose R; Dillon, Krista N; Salazar, Leonel Olivas; Canepa-Campos, Francisco; Rousselle, Serge D; Tellez, Armando
2015-12-01
Catheter-based renal sympathetic denervation is an emerging therapy for resistant hypertension (RHTN) patients, resulting in a significant blood pressure reduction. The presence of accessory renal arteries and anomalous branching patterns are reported in approximately 20-27 % of patients. However, accessory renal arteries, when smaller than 4 mm in diameter, they are out of the inclusion criteria for renal denervation therapy. For this reason patients with evidence of accessory renal arteries have been excluded in previous clinical trials. Recent data suggest that accessory renal arteries may play an important role in non-response therapy when they do not receive renal denervation treatment. In this report, we present the outcome of a patient with resistant hypertension and an anomalous right renal artery, having undergone denervation of both principal and accessory renal arteries. The renal ablation by radiofrequency energy of a distant accessory renal artery resulted in a safe procedure with no clinical complications. Consistent with literature the RDN of all, main and accessory renal arteries, was effective in decreasing patient blood pressure while decreasing the need for antihypertensive medication.
14 CFR 23.1165 - Engine ignition systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine ignition systems. 23.1165 Section 23... Controls and Accessories § 23.1165 Engine ignition systems. (a) Each battery ignition system must be... allow continued engine operation if any battery becomes depleted. (b) The capacity of batteries and...
46 CFR 119.458 - Portable fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps...
46 CFR 119.458 - Portable fuel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps...
49 CFR 393.83 - Exhaust systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Exhaust systems. 393.83 Section 393.83... NECESSARY FOR SAFE OPERATION Miscellaneous Parts and Accessories § 393.83 Exhaust systems. (a) Every motor... shall have a system to direct the discharge of such fumes. No part shall be located where its location...
14 CFR 23.1165 - Engine ignition systems.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine ignition systems. 23.1165 Section 23... Controls and Accessories § 23.1165 Engine ignition systems. (a) Each battery ignition system must be... allow continued engine operation if any battery becomes depleted. (b) The capacity of batteries and...
14 CFR 23.1165 - Engine ignition systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine ignition systems. 23.1165 Section 23... Controls and Accessories § 23.1165 Engine ignition systems. (a) Each battery ignition system must be... allow continued engine operation if any battery becomes depleted. (b) The capacity of batteries and...
75 FR 67634 - Parts and Accessories Necessary for Safe Operation: Antilock Brake Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-03
... trailer with an antilock brake system be equipped with an external malfunction indicator lamp. DATES: This... malfunction indicator lamp. FMCSA used the Agency's direct final rule procedures (75 FR 29915, May 28, 2010...
Using the Wii Balance Board in Elevator Physics
NASA Astrophysics Data System (ADS)
Mullenax, Donna
2013-04-01
The Wii Balance Board is a popular accessory to the wireless video system the Wii. In the past few years, the Wii Remote™ and Wii Balance Board accessories to the Wii have made their way into physics labs as sensors to measure force and acceleration. In most introductory physics courses, the forces experienced while on an elevator are discussed and calculated. The Wii Balance Board is a very good tool for having students measure the forces experienced on an elevator and calculating the acceleration of the elevator when it starts to move and then while it is coming to a stop.
Biosynthesis of the Urease Metallocenter*
Farrugia, Mark A.; Macomber, Lee; Hausinger, Robert P.
2013-01-01
Metalloenzymes often require elaborate metallocenter assembly systems to create functional active sites. The medically important dinuclear nickel enzyme urease provides an excellent model for studying metallocenter assembly. Nickel is inserted into the urease active site in a GTP-dependent process with the assistance of UreD/UreH, UreE, UreF, and UreG. These accessory proteins orchestrate apoprotein activation by delivering the appropriate metal, facilitating protein conformational changes, and possibly providing a requisite post-translational modification. The activation mechanism and roles of each accessory protein in urease maturation are the subject of ongoing studies, with the latest findings presented in this minireview. PMID:23539618
Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P
1995-01-01
Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval < or = 50 ms, electrogram stability (left-sided targets only), retrograde accessory pathway potential (right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.
1980-01-01
Accessory fibers in most sperm surround the axoneme so that their function in propulsion is difficult to assess. In the sperm of the toad Bufo marinus, an accessory fiber is displaced from the axoneme, being connected to it by the thin undulating membrane in such a way that the movement of axoneme and accessory fiber can be viewed independently. The axoneme is highly convoluted in whole mounts, and the axial fiber is straight. Cinemicrographic analysis shows that it is the longer, flexuous fiber, the presumed axoneme, that move actively. The accessory fiber follows it passively with a lower amplitude of movement. The accessory fiber does not move independent of the axoneme, even after demembranation and reactivation of the sperm. On the basis of anatomical relations in the neck region, it appears that the accessory fibers of amphibians are analogous to the dense fibers of mammalian sperm. SDS polyacrylamide gel electrophoresis of demembranated toad sperm tails reveals two principal proteins in addition to the tubulins, the former probably arising from the accessory fibers and the matrix of the undulating membrane. The function of displacing an accessory fiber into an undulating membrane may be to provide stiffness for the tail without incurring an energy deficit large enough to require a long middle piece. A long middle piece is not present in toad sperm, in contrast to those sperm that have accessory fibers around the axoneme. However, the toad sperm suffers a reduction in speed of about one- third, compared with the speed expected for a sperm without an undulating membrane. PMID:6771299
Crystallization of accessory phases in magmas by local saturation adjacent to phenocrysts
Bacon, C.R.
1989-01-01
Accessory minerals commonly occur attached to or included in the major crystalline phases of felsic and some intermediate igneous rocks. Apatite is particularly common as inclusions, but Fe-Ti oxides, pyrrhotite, zircon, monazite, chevkinite and xenotime are also known from silicic rocks. Accessories may nucleate near the host crystal/ liquid interface as a result of local saturation owing to formation of a differentiated chemical boundary layer in which accessory mineral solubility would be lower than in the surrounding liquid. Differentiation of this boundary layer would be greatest adjacent to ferromagnesian phenocrysts, especially Fe-Ti oxides; it is with oxides that accessories are most commonly associated in rocks. A boundary layer may develop if the crystal grows more rapidly than diffusion can transport incorporated and rejected elements to and from the phenocryst. Diffusion must dominate over convection as a mode of mass transfer near the advancing crystal/liquid interface in order for a boundary layer to exist. Accumulation of essential structural constituent elements of accessory minerals owing to their slow diffusion in evolved silicate melt also may force local saturation, but this is not a process that applies to all cases. Local saturation is an attractive mechanism for enhancing fractionation during crystallization differentiation. If accessory minerals attached to or included in phenocrysts formed because of local saturation, their host phenocrysts must have grown rapidly when accessories nucleated in comparison to lifetimes of magma reservoirs. Some inconsistencies remain in a local saturation origin for accessory phases that cannot be evaluated without additional information. ?? 1989.
49 CFR 393.69 - Liquefied petroleum gas systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Protection Association, Battery March Park, Quincy, MA 02269, as follows: (1) A fuel system installed before... ACCESSORIES NECESSARY FOR SAFE OPERATION Fuel Systems § 393.69 Liquefied petroleum gas systems. (a) A fuel system that uses liquefied petroleum gas as a fuel for the operation of a motor vehicle or for the...
Automotive Electrical and Electronic System II; Automotive Mechanics-Intermediate: 9045.04.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This automotive electrical and electronic system course is an intermediate course designed for the student who has completed automotive Electrical and Electronic System I. The theory and principles of operation of the components of the starting and charging systems and other electrical accessory systems in the automobile will be learned by the…
49 CFR 393.69 - Liquefied petroleum gas systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Liquefied petroleum gas systems. 393.69 Section... ACCESSORIES NECESSARY FOR SAFE OPERATION Fuel Systems § 393.69 Liquefied petroleum gas systems. (a) A fuel system that uses liquefied petroleum gas as a fuel for the operation of a motor vehicle or for the...
NASA Astrophysics Data System (ADS)
Sarakinos, A.; Lembessis, A.; Zervos, N.
2013-02-01
In this paper we will present the Z-Lab transportable color holography system, the HoLoFoS illuminator and results of actual in situ recording of color Denisyuk holograms of artifacts on panchromatic silver halide emulsions. Z-lab and HoLoFoS were developed to meet identified prerequisites of holographic recording of artifacts: a) in situ recording b) a high degree of detail and color reproduction c) a low degree of image distortions. The Z-Lab consists of the Z3RGB camera, its accessories and a mobile darkroom. HoLoFoS is an RGB LED-based lighting device for the display of color holograms. The device is capable of digitally controlled intensity mixing and provides a beam of uniform color cross section. The small footprint and emission characteristics of the device LEDs result in a narrow band, quasi point source at selected wavelengths. A case study in recording and displaying 'Optical Clones' of Greek cultural heritage artifacts with the aforementioned systems will also be presented.
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
Nandi, Tannistha; Holden, Matthew T.G.; Didelot, Xavier; Mehershahi, Kurosh; Boddey, Justin A.; Beacham, Ifor; Peak, Ian; Harting, John; Baybayan, Primo; Guo, Yan; Wang, Susana; How, Lee Chee; Sim, Bernice; Essex-Lopresti, Angela; Sarkar-Tyson, Mitali; Nelson, Michelle; Smither, Sophie; Ong, Catherine; Aw, Lay Tin; Hoon, Chua Hui; Michell, Stephen; Studholme, David J.; Titball, Richard; Chen, Swaine L.; Parkhill, Julian
2015-01-01
Burkholderia pseudomallei (Bp) is the causative agent of the infectious disease melioidosis. To investigate population diversity, recombination, and horizontal gene transfer in closely related Bp isolates, we performed whole-genome sequencing (WGS) on 106 clinical, animal, and environmental strains from a restricted Asian locale. Whole-genome phylogenies resolved multiple genomic clades of Bp, largely congruent with multilocus sequence typing (MLST). We discovered widespread recombination in the Bp core genome, involving hundreds of regions associated with multiple haplotypes. Highly recombinant regions exhibited functional enrichments that may contribute to virulence. We observed clade-specific patterns of recombination and accessory gene exchange, and provide evidence that this is likely due to ongoing recombination between clade members. Reciprocally, interclade exchanges were rarely observed, suggesting mechanisms restricting gene flow between clades. Interrogation of accessory elements revealed that each clade harbored a distinct complement of restriction-modification (RM) systems, predicted to cause clade-specific patterns of DNA methylation. Using methylome sequencing, we confirmed that representative strains from separate clades indeed exhibit distinct methylation profiles. Finally, using an E. coli system, we demonstrate that Bp RM systems can inhibit uptake of non-self DNA. Our data suggest that RM systems borne on mobile elements, besides preventing foreign DNA invasion, may also contribute to limiting exchanges of genetic material between individuals of the same species. Genomic clades may thus represent functional units of genetic isolation in Bp, modulating intraspecies genetic diversity. PMID:25236617
Maurice, Matthew J; Kaouk, Jihad H
2017-12-01
To assess the feasibility of radical perineal cystoprostatectomy using the latest generation purpose-built single-port robotic surgical system. In two male cadavers the da Vinci ® SP1098 Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) was used to perform radical perineal cystoprostatectomy and bilateral extended pelvic lymph node dissection (ePLND). New features in this model include enhanced high-definition three-dimensional optics, improved instrument manoeuvrability, and a real-time instrument tracking and guidance system. The surgery was accomplished through a 3-cm perineal incision via a novel robotic single-port system, which accommodates three double-jointed articulating robotic instruments, an articulating camera, and an accessory laparoscopic instrument. The primary outcomes were technical feasibility, intraoperative complications, and total robotic operative time. The cases were completed successfully without conversion. There were no accidental punctures or lacerations. The robotic operative times were 197 and 202 min. In this preclinical model, robotic radical perineal cystoprostatectomy and ePLND was feasible using the SP1098 robotic platform. Further investigation is needed to assess the feasibility of urinary diversion using this novel approach and new technology. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Functional organization of glomerular maps in the mouse accessory olfactory bulb
Hammen, Gary F.; Turaga, Diwakar; Holy, Timothy E.; Meeks, Julian P.
2014-01-01
Summary The mammalian accessory olfactory system (AOS) extracts information about species, sex, and individual identity from social odors, but its functional organization remains unclear. We imaged presynaptic Ca2+ signals in vomeronasal inputs to the accessory olfactory bulb (AOB) during peripheral stimulation using light sheet microscopy. Urine- and steroid-responsive glomeruli densely innervated the anterior AOB. Glomerular activity maps for sexually mature female mouse urine overlapped maps for juvenile and/or gonadectomized urine of both sexes, whereas maps for sexually mature male urine were highly distinct. Further spatial analysis revealed a complicated organization involving selective juxtaposition and dispersal of functionally-grouped glomerular classes. Glomeruli that were similarly tuned to urines were often closely associated, whereas more disparately tuned glomeruli were selectively dispersed. Maps to a panel of sulfated steroid odorants identified tightly-juxtaposed groups that were disparately tuned and dispersed groups that were similarly tuned. These results reveal a modular, non-chemotopic spatial organization in the AOB. PMID:24880215
The olfactory gonadotropin-releasing hormone immunoreactive system in mouse.
Jennes, L
1986-10-29
The olfactory gonadotropin-releasing hormone (GnRH) system in mice was studied with immunofluorescence in combination with lesions of the olfactory bulb and retrograde transport of horseradish peroxidase (HRP) which was administered intravascularly, intranasally or into the subarachnoid space. GnRH-positive neurons were located in the two major branches forming the septal roots of the nervus terminalis, in the ganglion terminale, within the fascicles of the nervus terminalis throughout its extent, in a conspicuous band which connects the ventral neck of the caudal olfactory bulb with the accessory olfactory bulb and in the nasal mucosa. GnRH-positive fibers were seen in all areas in which neurons were found, i.e. in the rostral septum, the ganglion and nervus terminalis and in the nasal subepithelium. In addition, a broad bundle of fibers was observed to surround the entire caudal olfactory bulb, connecting the rostral sulcus rhinalis with the ventrocaudal olfactory bulb. Fibers were seen in close association with the main and accessory olfactory bulb, with the fila olfactoria and with the nasal mucosa. Throughout the olfactory bulb and the nasal epithelium, an association of GnRH fibers with blood vessels was apparent. Intravascular and intranasal injection of HRP resulted in labeling of certain GnRH neurons in the septal roots of the nervus terminalis, the ganglion terminale, the nervus terminalis, the caudal ventrodorsal connection and in the accessory olfactory bulb. After placement of HRP into the subarachnoid space dorsal to the accessory olfactory bulb, about 50% of the GnRH neurons in the accessory olfactory bulb and in the ventrodorsal connection were labeled with HRP. Also, a few GnRH neurons in the rostral septum, the ganglion terminale and in the fascicles of the nervus terminalis had taken up the enzyme. Lesions of the nervus terminalis caudal to the ganglion terminale resulted in sprouting of GnRH fibers at both sites of the knife cut. Lesions rostral to the ganglion terminale induced sprouting mostly at the distal site of the knife cut while most but not all GnRH fibers proximal to the lesion had disappeared. The results of the present study indicate that the olfactory GnRH system is mostly associated with the nervus terminalis. This cranial nerve apparently projects to the central nervous system as well as the periphery. The results of the HRP uptake studies suggest that the GnRH neurons in the nervus terminalis have access to fenestrated capillaries in the subepithelial connective tissue of the nasal mucosa, to the nasal epithelium proper, and to the subarachnoid space.(ABSTRACT TRUNCATED AT 400 WORDS)
Kassem, Mohammad W; Iwanaga, Joe; Loukas, Marios; Stone, Jonathan J; Smith, Jay; Spinner, Robert J; Tubbs, R Shane
2018-04-01
Inflammatory etiologies are becoming increasingly recognized as explanations of some neuropathies, especially those occurring in the perioperative period. Although "brachial neuritis" is known to affect extraplexal nerves, accessory nerve palsy following median sternotomy has been attributed to stretch on the nerve. To better elucidate stretch as a potential cause, a cadaveric study was performed. Two patients who developed accessory nerve palsy following median sternotomy are presented to illustrate features consistent with the diagnosis of a perioperative inflammatory neuropathy. Five adult unembalmed cadavers underwent exposure of the bilateral accessory nerves in the posterior cervical triangle. A median sternotomy was performed and self-retaining retractors positioned. With the head in neutral, left rotation and right rotation, retractors were opened as during surgery while observing and recording any accessory nerve movements. The self-retaining sternal retractors were fully opened to a mean inter-blade distance of 13 cm. Regardless of head position, from the initial retractor click to maximal opening there was no gross movement of the accessory nerve on the left or right sides. Opening self-retaining sternal retractors does not appear to stretch the accessory nerve in the posterior cervical triangle. Based on our clinical experience and cadaveric results, we believe that inflammatory conditions, (i.e., idiopathic brachial plexitis) can involve the accessory nerve, and might be triggered by surgical procedures. Clin. Anat. 31:417-421, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
14 CFR 23.1437 - Accessories for multiengine airplanes.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes...
14 CFR 23.1437 - Accessories for multiengine airplanes.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes...
14 CFR 23.1437 - Accessories for multiengine airplanes.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes...
Three Accessories for a Rotating Platform.
ERIC Educational Resources Information Center
Riley, James A.; Fryer, Oscar G.
1980-01-01
Describes three accessories developed to be used in conjunction with the rotating platform or turntable. Three demonstrations using these accessories are included. These demonstrations are: (a) conservation of angular momentum; (b) gravity-defying goblets; and (c) direct measurement of centripetal force. (HM)
Cao, Honghui; Tang, Kanglai; Deng, Yinshuan; Tan, Xiaokang; Zhou, Binghua; Tao, Xu; Chen, Lei; Chen, Qianbo
2012-06-01
To analyze the excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular for the treatment of flatfoot related with accessory navicular and to evaluate its effectiveness. Between May 2006 and June 2011, 33 patients (40 feet) with flatfoot related with accessory navicular were treated. There were 14 males (17 feet) and 19 females (23 feet) with an average age of 30.1 years (range, 16-56 years). All patients had bilateral accessory navicular; 26 had unilateral flatfoot and 7 had bilateral flatfeet. The disease duration ranged from 7 months to 9 years (median, 24 months). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-midfoot score was 47.9 +/- 7.3. The X-ray films showed type II accessory navicular, the arch height loss, and heel valgus in all patients. All of them received excision of accessory navicular and reconstruction of posterior tibial tendon insertion on navicular with anchor. All patients got primary wound healing without any complication. Thirty patients (36 feet) were followed up 6-54 months with an average of 23 months. All patients achieved complete pain relief at 6 months after surgery and had good appearance of the feet. The AOFAS ankle-midfoot score was 90.4 +/- 2.0 at last follow-up, showing significant difference when compared with preoperative score (t=29.73, P=0.00). X-ray films showed that no screw loosening or breakage was observed. There were significant differences in the arch height, calcaneus inclination angle, talocalcaneal angle, and talar-first metatarsal angle between pre-operation and last follow-up (P < 0.01). The excision of accessory navicular with reconstruction of posterior tibial tendon insertion on navicular is a good choice for the treatment of flatfoot related with accessory navicular, with correction of deformity, excellent effectiveness, and less complications.
Oxygen isotopes in garnet and accessory minerals to constrain fluids in subducted crust
NASA Astrophysics Data System (ADS)
Rubatto, Daniela; Gauthiez-Putallaz, Laure; Regis, Daniele; Rosa Scicchitano, Maria; Vho, Alice; Williams, Morgan
2017-04-01
Fluids are considered a fundamental agent for chemical exchanges between different rock types in the subduction system. Constraints on the sources and pathways of subduction fluids thus provide crucial information to reconstruct subduction processes. Garnet and U-Pb accessory minerals constitute some of the most robust and ubiquitous minerals in subducted crust and can preserve multiple growth zones that track the metamorphic evolution of the sample they are hosted in. Microbeam investigation of the chemical (major and trace elements) and isotopic composition (oxygen and U-Pb) of garnet and accessory minerals is used to track significant fluid-rock interaction at different stages of the subduction system. This approach requires consideration of the diffusivity of oxygen isotopes particularly in garnet, which has been investigated experimentally. The nature of the protolith and ocean floor alteration is preserved in relict accessory phases within eclogites that have been fully modified at HP conditions (e.g. Monviso and Dora Maira units in the Western Alps). Minerals in the lawsonite-blueschists of the Tavsanli zone in Turkey record pervasive fluid exchange between mafic and sedimentary blocks at the early stage of subduction. High pressure shear zones and lithological boundaries show evidence of intense fluid metasomatism at depth along discontinuities in Monviso and Corsica. In the UHP oceanic crust of the Zermatt-Saas Zone, garnet oxygen isotopes and tourmaline boron isotopes indicate multistage fluid infiltration during prograde metamorphism. Localized exchanges of aqueous fluids are also observed in the subducted continental crust of the Sesia-Lanzo Zone. In most cases analyses of distinct mineral zones enable identification of multiple pulses of fluids during the rock evolution.
21 CFR 870.4200 - Cardiopulmonary bypass accessory equipment.
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4200... mounting bracket or system-priming equipment. (b) Classification. (1) Class I. The device is classified as...
21 CFR 870.4200 - Cardiopulmonary bypass accessory equipment.
Code of Federal Regulations, 2012 CFR
2012-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4200... mounting bracket or system-priming equipment. (b) Classification. (1) Class I. The device is classified as...
21 CFR 870.4200 - Cardiopulmonary bypass accessory equipment.
Code of Federal Regulations, 2013 CFR
2013-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4200... mounting bracket or system-priming equipment. (b) Classification. (1) Class I. The device is classified as...
Chan, K L Andrew; Kazarian, Sergei G
2008-10-01
Attenuated total reflection-Fourier transform infrared (ATR-FT-IR) imaging is a very useful tool for capturing chemical images of various materials due to the simple sample preparation and the ability to measure wet samples or samples in an aqueous environment. However, the size of the array detector used for image acquisition is often limited and there is usually a trade off between spatial resolution and the field of view (FOV). The combination of mapping and imaging can be used to acquire images with a larger FOV without sacrificing spatial resolution. Previous attempts have demonstrated this using an infrared microscope and a Germanium hemispherical ATR crystal to achieve images of up to 2.5 mm x 2.5 mm but with varying spatial resolution and depth of penetration across the imaged area. In this paper, we demonstrate a combination of mapping and imaging with a different approach using an external optics housing for large ATR accessories and inverted ATR prisms to achieve ATR-FT-IR images with a large FOV and reasonable spatial resolution. The results have shown that a FOV of 10 mm x 14 mm can be obtained with a spatial resolution of approximately 40-60 microm when using an accessory that gives no magnification. A FOV of 1.3 mm x 1.3 mm can be obtained with spatial resolution of approximately 15-20 microm when using a diamond ATR imaging accessory with 4x magnification. No significant change in image quality such as spatial resolution or depth of penetration has been observed across the whole FOV with this method and the measurement time was approximately 15 minutes for an image consisting of 16 image tiles.
NASA Astrophysics Data System (ADS)
Tsai, Tsung-Han; Ahsen, Osman O.; Lee, Hsiang-Chieh; Liang, Kaicheng; Giacomelli, Michael G.; Potsaid, Benjamin M.; Tao, Yuankai K.; Jayaraman, Vijaysekhar; Kraus, Martin F.; Hornegger, Joachim; Figueiredo, Marisa; Huang, Qin; Mashimo, Hiroshi; Cable, Alex E.; Fujimoto, James G.
2014-03-01
We developed an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor based imaging catheter, which provided an imaging speed of 600 kHz axial scan rate and 8 μm axial resolution in tissue. The micromotor catheter was 3.2 mm in diameter and could be introduced through the 3.7 mm accessory port of an endoscope. Imaging was performed at 400 frames per second with an 8 μm spot size using a pullback to generate volumetric data over 16 mm with a pixel spacing of 5 μm in the longitudinal direction. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing standard upper and lower endoscopy at the Veterans Affairs Boston Healthcare System (VABHS). Patients with Barrett's esophagus, dysplasia, and inflammatory bowel disease were imaged. The use of distally actuated imaging catheters allowed OCT imaging with more flexibility such as volumetric imaging in the terminal ileum and the assessment of the hiatal hernia using retroflex imaging. The high rotational stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face and cross-sectional imaging. The ability to perform 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies to investigate the ability of OCT to detect pathology as well as assess treatment response.
[Ocular surface system integrity].
Safonova, T N; Pateyuk, L S
2015-01-01
The interplay of different structures belonging to either the anterior segment of the eye or its accessory visual apparatus, which all share common embryological, anatomical, functional, and physiological features, is discussed. Explanation of such terms, as ocular surface, lacrimal functional unit, and ocular surface system, is provided.
22 CFR 129.7 - Prior approval (license).
Code of Federal Regulations, 2010 CFR
2010-04-01
...; (ii) Nuclear weapons strategic delivery systems and all components, parts, accessories, attachments specifically designed for such systems and associated equipment; (iii) Nuclear weapons design and test equipment of a nature described by Category XVI of Part 121; (iv) Naval nuclear propulsion equipment of a...
22 CFR 129.7 - Prior approval (license).
Code of Federal Regulations, 2011 CFR
2011-04-01
...; (ii) Nuclear weapons strategic delivery systems and all components, parts, accessories, attachments specifically designed for such systems and associated equipment; (iii) Nuclear weapons design and test equipment of a nature described by Category XVI of part 121; (iv) Naval nuclear propulsion equipment of a...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...
14 CFR 23.1437 - Accessories for multiengine airplanes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Accessories for multiengine airplanes. 23.1437 Section 23.1437 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., engine-driven accessories essential to safe operation must be distributed among two or more engines so...
14 CFR 23.1437 - Accessories for multiengine airplanes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Accessories for multiengine airplanes. 23.1437 Section 23.1437 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF..., engine-driven accessories essential to safe operation must be distributed among two or more engines so...
21 CFR 886.1930 - Tonometer and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1930 Tonometer and accessories. (a) Identification. A tonometer and accessories is a manual device intended to measure intraocular pressure by applying a known force on the globe of the eye and measuring the amount of indentation produced (Schiotz...
Hünig, T; Loos, M; Schimpl, A
1983-01-01
Recent studies from other laboratories have shown that concanavalin A (Con A) acts at two separate steps in polyclonal T cell activation: interleukin 2 (IL2) production, and induction of responsiveness to IL2. Using a combination of techniques for the depletion of accessory cells from lymph node T cells, we have investigated which of these steps, if not both, is responsible for the known requirement for accessory cells in the Con A response. It was found that with increasing T cell purification, first the ability is lost to produce sufficient levels of endogenous IL2, whereas induction of IL2 responsiveness can still take place. Further removal of accessory cells however yields a population of resting T cells that cannot be induced by Con A to become IL2-reactive. It was concluded that both IL2 production and induction of reactivity to IL2 are accessory cell-dependent events.
Variations in the surface anatomy of the spinal accessory nerve in the posterior triangle.
Symes, A; Ellis, H
2005-12-01
Iatrogenic injury to the spinal accessory nerve has been widely documented and can have medico-legal implications. The resulting syndrome of pain, paralysis and winging of the scapula are often the source of considerable morbidity. This paper researches the degree of accuracy achievable in mapping the surface anatomy of the spinal accessory nerve in the region of the posterior triangle with a view to creating a cartographical aid to surgical procedures. The necks of 25 adult cadavers were dissected bilaterally to expose the spinal accessory nerve. Variations in the course and distribution of the spinal accessory nerve in the posterior triangle were recorded along with its relationship to the borders of sternocleidomastoid and trapezius. Considerable variation was seen in the surface and regional anatomy of the nerve and in the contribution of the cervical plexus to the spinal accessory nerve in the posterior triangle. Measurements of the running course and exit point of the nerve into and from the posterior triangle differed significantly from those previously recorded. Delineation of an accurate surface anatomy was not possible. Creating a map to define the surface anatomy of the spinal accessory nerve in the posterior triangle is an unrealistic goal given its wide variations in man. Avoidance of damage to the spinal accessory nerve cannot be achieved by slavishly adhering to surface markings given in textbooks, but only by cautious dissection during operations on the posterior triangle.
Bohlin, Jon; Eldholm, Vegard; Pettersson, John H O; Brynildsrud, Ola; Snipen, Lars
2017-02-10
The core genome consists of genes shared by the vast majority of a species and is therefore assumed to have been subjected to substantially stronger purifying selection than the more mobile elements of the genome, also known as the accessory genome. Here we examine intragenic base composition differences in core genomes and corresponding accessory genomes in 36 species, represented by the genomes of 731 bacterial strains, to assess the impact of selective forces on base composition in microbes. We also explore, in turn, how these results compare with findings for whole genome intragenic regions. We found that GC content in coding regions is significantly higher in core genomes than accessory genomes and whole genomes. Likewise, GC content variation within coding regions was significantly lower in core genomes than in accessory genomes and whole genomes. Relative entropy in coding regions, measured as the difference between observed and expected trinucleotide frequencies estimated from mononucleotide frequencies, was significantly higher in the core genomes than in accessory and whole genomes. Relative entropy was positively associated with coding region GC content within the accessory genomes, but not within the corresponding coding regions of core or whole genomes. The higher intragenic GC content and relative entropy, as well as the lower GC content variation, observed in the core genomes is most likely associated with selective constraints. It is unclear whether the positive association between GC content and relative entropy in the more mobile accessory genomes constitutes signatures of selection or selective neutral processes.
Hovis, Kenneth R.; Ramnath, Rohit; Dahlen, Jeffrey E.; Romanova, Anna L.; LaRocca, Greg; Bier, Mark E.; Urban, Nathaniel N.
2012-01-01
The mammalian accessory olfactory system is specialized for the detection of chemicals that identify kin and conspecifics. Vomeronasal sensory neurons (VSNs), residing in the vomeronasal organ, project axons to the accessory olfactory bulb (AOB) where they form synapses with principle neurons, known as mitral cells. The organization of this projection is quite precise and is believed to be essential for appropriate function of this system. However, how this precise connectivity is established is unknown. We show here that in mice the vomeronasal duct is open at birth, allowing external chemical stimuli access to sensory neurons, and that these sensory neurons are capable of releasing neurotransmitter to downstream neurons as early as the first post-natal day. Using major histocompatibility complex class I (MHC-1) peptides to activate a selective subset of VSNs during the first few post-natal days of development, we show that increased activity results in exuberant VSN axonal projections and a delay in axonal coalescence into well-defined glomeruli in the AOB. Finally, we show that mitral cell dendritic refinement occurs just after the coalescence of pre-synaptic axons. Such a mechanism may allow the formation of precise connectivity with specific glomeruli that receive input from sensory neurons expressing the same receptor type. PMID:22674266
21 CFR 884.5350 - Contraceptive diaphragm and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...
21 CFR 884.5350 - Contraceptive diaphragm and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...
21 CFR 884.5350 - Contraceptive diaphragm and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...
21 CFR 884.5350 - Contraceptive diaphragm and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...
21 CFR 884.5350 - Contraceptive diaphragm and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive diaphragm...
21 CFR 890.5925 - Traction accessory.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...
21 CFR 890.5925 - Traction accessory.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...
21 CFR 890.5925 - Traction accessory.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...
21 CFR 890.5925 - Traction accessory.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...
21 CFR 890.5925 - Traction accessory.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory. (a...
21 CFR 864.3600 - Microscopes and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...
21 CFR 864.3600 - Microscopes and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...
21 CFR 864.3600 - Microscopes and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...
21 CFR 864.3600 - Microscopes and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864.3600...
14 CFR 221.52 - Airport to airport application, accessorial services.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...
14 CFR 221.52 - Airport to airport application, accessorial services.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...
14 CFR 221.52 - Airport to airport application, accessorial services.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...
14 CFR 221.52 - Airport to airport application, accessorial services.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...
14 CFR 221.52 - Airport to airport application, accessorial services.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Airport to airport application, accessorial... Charges § 221.52 Airport to airport application, accessorial services. Tariffs shall specify whether or not the fares therein include services in addition to airport-to-airport transportation. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-17
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-754] Certain Handbags, Luggage, Accessories, and Packaging Thereof; Determination Not To Review an Initial Determination Granting Complainant... importation of certain handbags, luggage, accessories, and packaging thereof by reason of infringement of U.S...
Sturm, Robert
2008-01-01
The morphology and histology of the ductus receptaculi and accessory glands in females of the black field cricket, Teleogryllus commodus Walker (Orthoptera: Gryllidae) are described. Both are reproductive organs situated in the 7th and 8th abdominal segment that join the posterior part of the genital chamber. The ductus receptaculi is a long (up to 25 mm) homogeneous tube, and the accessory glands (total length: 4 to 12 mm) are a complex system of tubes and end lobes with various numbers of ramifications. Based on their external shapes the accessory glands may be subdivided into three distinct regions, a distal region mainly producing the gland's secretion, a middle conducting region, and a basal region serving for the storage and release of the secretory substances into the genital chamber of the female. In histological respects, both organs have an outer muscle coat followed by a basal lamina, one or two cell layers, the cuticular intima, and the inner lumen. The ductus receptaculi is subdivided into three histologically different regions. The region located adjacent to the receptaculum and the region neighbouring the terminal papilla consist of a single, epithelial cell layer that is not secretory. The epithelium of the middle region contains two cell layers, glandular cells and cuticula-forming cells, which are responsible for the production of the cuticular intima. The secretion of the gland cells is released into an extracellular cavity, through which it reaches the lumen via a complex network of canals running through the intima. The histology of the accessory glands is rather homogeneous among the different regions, as one layer of epithelial cells produces both the secretion and the cuticular intima. Histological variations in the distal, middle, and basal gland sections mainly concern the height of the epithelium, the thickness of the basal lamina and the cuticular intima as well as the variable presence of the outer muscle coat. In contrast to the ductus receptaculi, secretory substances produced by the accessory gland cells accumulate in the lumen by a diffusive permeation of the intima. PMID:20298118
Central neural coding of sky polarization in insects.
Homberg, Uwe; Heinze, Stanley; Pfeiffer, Keram; Kinoshita, Michiyo; el Jundi, Basil
2011-03-12
Many animals rely on a sun compass for spatial orientation and long-range navigation. In addition to the Sun, insects also exploit the polarization pattern and chromatic gradient of the sky for estimating navigational directions. Analysis of polarization-vision pathways in locusts and crickets has shed first light on brain areas involved in sky compass orientation. Detection of sky polarization relies on specialized photoreceptor cells in a small dorsal rim area of the compound eye. Brain areas involved in polarization processing include parts of the lamina, medulla and lobula of the optic lobe and, in the central brain, the anterior optic tubercle, the lateral accessory lobe and the central complex. In the optic lobe, polarization sensitivity and contrast are enhanced through convergence and opponency. In the anterior optic tubercle, polarized-light signals are integrated with information on the chromatic contrast of the sky. Tubercle neurons combine responses to the UV/green contrast and e-vector orientation of the sky and compensate for diurnal changes of the celestial polarization pattern associated with changes in solar elevation. In the central complex, a topographic representation of e-vector tunings underlies the columnar organization and suggests that this brain area serves as an internal compass coding for spatial directions.
Central neural coding of sky polarization in insects
Homberg, Uwe; Heinze, Stanley; Pfeiffer, Keram; Kinoshita, Michiyo; el Jundi, Basil
2011-01-01
Many animals rely on a sun compass for spatial orientation and long-range navigation. In addition to the Sun, insects also exploit the polarization pattern and chromatic gradient of the sky for estimating navigational directions. Analysis of polarization–vision pathways in locusts and crickets has shed first light on brain areas involved in sky compass orientation. Detection of sky polarization relies on specialized photoreceptor cells in a small dorsal rim area of the compound eye. Brain areas involved in polarization processing include parts of the lamina, medulla and lobula of the optic lobe and, in the central brain, the anterior optic tubercle, the lateral accessory lobe and the central complex. In the optic lobe, polarization sensitivity and contrast are enhanced through convergence and opponency. In the anterior optic tubercle, polarized-light signals are integrated with information on the chromatic contrast of the sky. Tubercle neurons combine responses to the UV/green contrast and e-vector orientation of the sky and compensate for diurnal changes of the celestial polarization pattern associated with changes in solar elevation. In the central complex, a topographic representation of e-vector tunings underlies the columnar organization and suggests that this brain area serves as an internal compass coding for spatial directions. PMID:21282171
Quiet Clean Short-Haul Experimental Engine (QCSEE). Preliminary analyses and design report, volume 2
NASA Technical Reports Server (NTRS)
1974-01-01
The experimental and flight propulsion systems are presented. The following areas are discussed: engine core and low pressure turbine design; bearings and seals design; controls and accessories design; nacelle aerodynamic design; nacelle mechanical design; weight; and aircraft systems design.
21 CFR 884.4120 - Gynecologic electrocautery and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gynecologic electrocautery and accessories. 884.4120 Section 884.4120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... under direct visual observation. This generic type of device may include the following accessories: an...
21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...
21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...
21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...
21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...
21 CFR 888.3030 - Single/multiple component metallic bone fixation appliances and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Single/multiple component metallic bone fixation....3030 Single/multiple component metallic bone fixation appliances and accessories. (a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be...
21 CFR 884.1300 - Uterotubal carbon dioxide insufflator and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Uterotubal carbon dioxide insufflator and... Gynecological Diagnostic Devices § 884.1300 Uterotubal carbon dioxide insufflator and accessories. (a) Identification. A uterotubal carbon dioxide insufflator and accessories is a device used to test the patency...
47 CFR 15.27 - Special accessories.
Code of Federal Regulations, 2010 CFR
2010-10-01
... information required by this section may be included in the manual in that alternative form, provided the user..., shall ensure that these special accessories are provided with the equipment. The instruction manual for... responsibility of the user to use the needed special accessories supplied with the equipment. In cases where the...
21 CFR 884.1300 - Uterotubal carbon dioxide insufflator and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Uterotubal carbon dioxide insufflator and... Gynecological Diagnostic Devices § 884.1300 Uterotubal carbon dioxide insufflator and accessories. (a) Identification. A uterotubal carbon dioxide insufflator and accessories is a device used to test the patency...
21 CFR 884.1300 - Uterotubal carbon dioxide insufflator and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Uterotubal carbon dioxide insufflator and... Gynecological Diagnostic Devices § 884.1300 Uterotubal carbon dioxide insufflator and accessories. (a) Identification. A uterotubal carbon dioxide insufflator and accessories is a device used to test the patency...
14 CFR 23.1192 - Engine accessory compartment diaphragm.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the engine...
21 CFR 878.4400 - Electrosurgical cutting and coagulation device and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrosurgical cutting and coagulation device and....4400 Electrosurgical cutting and coagulation device and accessories. (a) Identification. An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic monitor is a device designed to transmit and receive ultrasonic energy into and from the pregnant woman...
21 CFR 884.2700 - Intrauterine pressure monitor and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... include the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2700 - Intrauterine pressure monitor and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... include the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2700 - Intrauterine pressure monitor and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... include the following accessories: signal analysis and display equipment, patient and equipment supports...
19 CFR 10.2020 - Accessories, spare parts, or tools.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.2020 Section 10.2020 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY... Trade Promotion Agreement Rules of Origin § 10.2020 Accessories, spare parts, or tools. (a) General...
14 CFR 23.1192 - Engine accessory compartment diaphragm.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the engine...
14 CFR 23.1192 - Engine accessory compartment diaphragm.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the engine...
21 CFR 878.1800 - Speculum and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...
21 CFR 878.1800 - Speculum and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...
21 CFR 878.1800 - Speculum and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...
21 CFR 878.1800 - Speculum and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...
21 CFR 878.1800 - Speculum and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and accessories...
21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...
21 CFR 888.5850 - Nonpowered orthopedic traction apparatus and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered orthopedic traction apparatus and accessories. 888.5850 Section 888.5850 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... orthopedic traction apparatus and accessories. (a) Identification. A nonpowered orthopedic traction apparatus...
19 CFR 10.600 - Accessories, spare parts, or tools.
Code of Federal Regulations, 2010 CFR
2010-04-01
...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or... 10.600 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT... of the good's standard accessories, spare parts, or tools will be treated as originating goods if the...
21 CFR 876.4890 - Urological table and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., stirrups, and belts used to support a patient in a suitable position for endoscopic procedures of the lower...) Class II (special controls) for the electrically powered urological table and accessories. The device is... § 876.9. (2) Class I for the manually powered table and accessories, and for stirrups for electrically...
Degrell, I
1979-08-02
The case of a 32-year-old female patient with multiple malformations (hare-lip, polythelia, fibroadenoma in an accessory mammary gland) and independent of these, another fibroadenoma in the breast is reported. The fibroadenoma developing in the accessory breast around the vulva, diagnosed by means of aspiration biopsy cytology, should be payed special attention. This case also confirms the applicability in preoperative diagnostics of aspiration biopsy cytology, a method which has proved to be effective for years.
Wang, Ce; Zhang, Ying; Nicholas, Tsai; Wu, Guoxin; Shi, Sheng; Bo, Yin; Wang, Xinwei; Zhou, Xuhui; Yuan, Wen
2014-01-01
High cervical spinal cord injury is associated with high morbidity and mortality. Traditional treatments carry various complications such as infection, pacemaker failure and undesirable movement. Thus, a secure surgical strategy with fewer complications analogous to physiological ventilation is still required. We hope to offer one potential method to decrease the complications and improve survival qualities of patients from the aspect of anatomy. The purpose of the study is to provide anatomic details on the accessory nerve and phrenic nerve for neurotization in patients with high spinal cord injuries. 38 cadavers (76 accessory and 76 phrenic nerves) were dissected in the study. The width, length and thickness of each accessory nerve and phrenic nerve above clavicle were measured. The distances from several landmarks on accessory nerve to the origin and the end of the phrenic nerve above clavicle were measured too. Then, the number of motor nerve fibers on different sections of the nerves was calculated using the technique of immunohistochemistry. The accessory nerves distal to its sternocleidomastoid muscular branches were 1.52 ± 0.32 mm ~1.54 ± 0.29 mm in width, 0.52 ± 0.18 mm ~ 0.56 ± 0.20mm in thickness and 9.52 ± 0.98 cm in length. And the phrenic nerves above clavicle were 1.44 ± 0.23 mm ~ 1.45 ± 0.24 mm in width, 0.47 ± 0.15 mm ~ 0.56 ± 0.25 mm in thickness and 6.48 ± 0.78 cm in length. The distance between the starting point of accessory nerve and phrenic nerve were 3.24 ± 1.17 cm, and the distance between the starting point of accessory nerve and the end of the phrenic nerve above clavicle were 8.72 ± 0.84 cm. The numbers of motor nerve fibers in accessory nerve were 1,038 ± 320~1,102 ± 216, before giving out the sternocleidomastoid muscular branches. The number of motor nerve fibers in the phrenic nerve was 911 ± 321~1,338 ± 467. The accessory nerve and the phrenic were similar in width, thickness and the number of motor nerve fibers. And the lengths of accessory nerve were long enough for neuritisation with phrenic nerve.
21 CFR 876.1735 - Electrogastrography system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...
21 CFR 876.1735 - Electrogastrography system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...
21 CFR 876.1735 - Electrogastrography system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...
21 CFR 876.1735 - Electrogastrography system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...
21 CFR 876.5630 - Peritoneal dialysis system and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the...”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal...
21 CFR 876.5630 - Peritoneal dialysis system and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the...”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal...
21 CFR 876.5630 - Peritoneal dialysis system and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the...”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal...
21 CFR 876.5630 - Peritoneal dialysis system and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the...”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal...
21 CFR 876.5630 - Peritoneal dialysis system and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... peritoneal dialysis, a source of dialysate, and, in some cases, a water purification mechanism. After the...”) or dialysate prepared from dialysate concentrate and sterile purified water (for automatic peritoneal...
Study of structural and optical properties of ZnS zigzag nanostructured thin films
NASA Astrophysics Data System (ADS)
Rahchamani, Seyyed Zabihollah; Rezagholipour Dizaji, Hamid; Ehsani, Mohammad Hossein
2015-11-01
Zinc sulfide (ZnS) nanostructured thin films of different thicknesses with zigzag shapes have been deposited on glass substrates by glancing angle deposition (GLAD) technique. Employing a homemade accessory attached to the substrate holder enabled the authors to control the substrate temperature and substrate angle. The prepared samples were subjected to X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM) and UV-VIS. spectroscopy techniques. The structural studies revealed that the film deposited at room temperature crystallized in cubic structure. The FESEM images of the samples confirmed the formation of zigzag nano-columnar shape with mean diameter about 60-80 nm. By using the data obtained from optical studies, the real part of the refractive index (n), the absorption coefficient (α) and the band gap (Eg) of the samples were calculated. The results show that the refractive indices of the prepared films are very sensitive to deposition conditions.
Simultaneous multi-beam planar array IR (pair) spectroscopy
Elmore, Douglas L.; Rabolt, John F.; Tsao, Mei-Wei
2005-09-13
An apparatus and method capable of providing spatially multiplexed IR spectral information simultaneously in real-time for multiple samples or multiple spatial areas of one sample using IR absorption phenomena requires no moving parts or Fourier Transform during operation, and self-compensates for background spectra and degradation of component performance over time. IR spectral information and chemical analysis of the samples is determined by using one or more IR sources, sampling accessories for positioning the samples, optically dispersive elements, a focal plane array (FPA) arranged to detect the dispersed light beams, and a processor and display to control the FPA, and display an IR spectrograph. Fiber-optic coupling can be used to allow remote sensing. Portability, reliability, and ruggedness is enhanced due to the no-moving part construction. Applications include determining time-resolved orientation and characteristics of materials, including polymer monolayers. Orthogonal polarizers may be used to determine certain material characteristics.
21 CFR 876.5830 - Hemodialyzer with disposable insert (Kiil type).
Code of Federal Regulations, 2012 CFR
2012-04-01
... extracorporeal blood system and the dialysate delivery system of the hemodialysis system and accessories (§ 876... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hemodialyzer with disposable insert (Kiil type). 876.5830 Section 876.5830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...
21 CFR 876.5830 - Hemodialyzer with disposable insert (Kiil type).
Code of Federal Regulations, 2013 CFR
2013-04-01
... extracorporeal blood system and the dialysate delivery system of the hemodialysis system and accessories (§ 876... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hemodialyzer with disposable insert (Kiil type). 876.5830 Section 876.5830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...
21 CFR 876.5830 - Hemodialyzer with disposable insert (Kiil type).
Code of Federal Regulations, 2011 CFR
2011-04-01
... extracorporeal blood system and the dialysate delivery system of the hemodialysis system and accessories (§ 876... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hemodialyzer with disposable insert (Kiil type). 876.5830 Section 876.5830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...
21 CFR 876.5830 - Hemodialyzer with disposable insert (Kiil type).
Code of Federal Regulations, 2014 CFR
2014-04-01
... extracorporeal blood system and the dialysate delivery system of the hemodialysis system and accessories (§ 876... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hemodialyzer with disposable insert (Kiil type). 876.5830 Section 876.5830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
21 CFR 862.2250 - Gas liquid chromatography system for clinical use.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid... pressure. The device may include accessories such as columns, gases, column supports, and liquid coating...
2009-01-01
Background Bacterial genomes are mosaic structures composed of genes present in every strain of the same species (core genome), and genes present in some but not all strains of a species (accessory genome). The aim of this study was to compare the genetic diversity of core and accessory genes of a Salmonella enterica subspecies enterica serovar Typhimurium (Typhimurium) population isolated from food-animal and human sources in four regions of Mexico. Multilocus sequence typing (MLST) and macrorestriction fingerprints by pulsed-field gel electrophoresis (PFGE) were used to address the core genetic variation, and genes involved in pathogenesis and antibiotic resistance were selected to evaluate the accessory genome. Results We found a low genetic diversity for both housekeeping and accessory genes. Sequence type 19 (ST19) was supported as the founder genotype of STs 213, 302 and 429. We found a temporal pattern in which the derived ST213 is replacing the founder ST19 in the four geographic regions analyzed and a geographic trend in the number of resistance determinants. The distribution of the accessory genes was not random among chromosomal genotypes. We detected strong associations among the different accessory genes and the multilocus chromosomal genotypes (STs). First, the Salmonella virulence plasmid (pSTV) was found mostly in ST19 isolates. Second, the plasmid-borne betalactamase cmy-2 was found only in ST213 isolates. Third, the most abundant integron, IP-1 (dfrA12, orfF and aadA2), was found only in ST213 isolates. Fourth, the Salmonella genomic island (SGI1) was found mainly in a subgroup of ST19 isolates carrying pSTV. The mapping of accessory genes and multilocus genotypes on the dendrogram derived from macrorestiction fingerprints allowed the establishment of genetic subgroups within the population. Conclusion Despite the low levels of genetic diversity of core and accessory genes, the non-random distribution of the accessory genes across chromosomal backgrounds allowed us to discover genetic subgroups within the population. This study provides information about the importance of the accessory genome in generating genetic variability within a bacterial population. PMID:19573249
21 CFR 876.5540 - Blood access device and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...
21 CFR 876.5540 - Blood access device and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...
21 CFR 876.5540 - Blood access device and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...
21 CFR 876.5540 - Blood access device and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...
21 CFR 876.5540 - Blood access device and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... is part of an artificial kidney system for the treatment of patients with renal failure or toxemic... dilator, disconnect forceps, shunt guard, crimp plier, tube plier, crimp ring, joint ring, fistula adaptor...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-16
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,106; TA-W-71,106A] Paris Accessories, Inc., Including On-Site Leased Workers From Job Connections, New Smithville, PA; Paris... Paris Accessories, Inc., including on-site leased workers from Job Connections, New Smithville...
14 CFR 125.149 - Engine accessory section diaphragm.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...
14 CFR 125.149 - Engine accessory section diaphragm.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...
14 CFR 125.149 - Engine accessory section diaphragm.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...
14 CFR 125.149 - Engine accessory section diaphragm.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-05
..., Accessories and Packaging Thereof; Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION... packaging thereof by reason of infringement of U.S. Trademark Registration No. 297,594 (``the `594 trademark... certain handbags, luggage, accessories and packaging thereof that infringe the `594 trademark; the `625...
29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto...
A left lateral accessory pathway unmasked by rivastigmine.
Guenancia, Charles; Fichot, Marie; Garnier, Fabien; Montoy, Mathieu; Laurent, Gabriel
A 75-year-old woman was referred for advice regarding surface electrocardiographic modifications after the initiation of rivastigmine. In our patient, the baseline ECGs appeared perfectly normal. However, the initiation of a cholinesterase inhibitor unmasked a left lateral accessory pathway that had never been diagnosed before. Although cholinesterase inhibitors are known to increase vagal tone, the PR interval was shortened after rivastigmine administration, thus excluding this hypothesis to explain the appearance of the accessory pathway. Therefore, we hypothesized that cholinesterase inhibitors may have increased conduction velocity in the accessory pathway or in the atria. Copyright © 2017 Elsevier Inc. All rights reserved.
29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...
Simon Effect with and without Awareness of the Accessory Stimulus
ERIC Educational Resources Information Center
Treccani, Barbara; Umilta, Carlo; Tagliabue, Mariaelena
2006-01-01
The authors investigated whether a Simon effect could be observed in an accessory-stimulus Simon task when participants were unaware of the task-irrelevant accessory cue. In Experiment 1A a central visual target was accompanied by a suprathreshold visual lateral cue. A regular Simon effect (i.e., faster cue-response corresponding reaction times…
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... images of the small bowel with a wireless camera contained in a capsule. This device includes an... receiving/recording unit, a data storage device, computer software to process the images, and accessories...
24 CFR 3280.704 - Fuel supply systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... temporarily, inside any manufactured home except for listed, completely self-contained hand torches, lanterns... the material to be used. (4) LP-gas container valves and accessories. (i) Valves in the assembly of a...) Systems mounted on the “A” frame assembly shall be so located that the discharge from the safety relief...
24 CFR 3280.704 - Fuel supply systems.
Code of Federal Regulations, 2011 CFR
2011-04-01
... temporarily, inside any manufactured home except for listed, completely self-contained hand torches, lanterns... the material to be used. (4) LP-gas container valves and accessories. (i) Valves in the assembly of a...) Systems mounted on the “A” frame assembly shall be so located that the discharge from the safety relief...
21 CFR 892.1680 - Stationary x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Stationary x-ray system. 892.1680 Section 892.1680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... signal analysis and display equipment, patient and equipment supports, component parts, and accessories...
21 CFR 892.1680 - Stationary x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stationary x-ray system. 892.1680 Section 892.1680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... signal analysis and display equipment, patient and equipment supports, component parts, and accessories...
21 CFR 892.1680 - Stationary x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Stationary x-ray system. 892.1680 Section 892.1680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... signal analysis and display equipment, patient and equipment supports, component parts, and accessories...
21 CFR 892.1680 - Stationary x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Stationary x-ray system. 892.1680 Section 892.1680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... signal analysis and display equipment, patient and equipment supports, component parts, and accessories...
21 CFR 892.1680 - Stationary x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Stationary x-ray system. 892.1680 Section 892.1680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... signal analysis and display equipment, patient and equipment supports, component parts, and accessories...
Direct Multizone System -- DMS1-275.
ERIC Educational Resources Information Center
Lennox Industries, Inc., Marshalltown, IA.
Lennox Direct Multizone System as a new concept for integrated comfort control is described. The following areas of concern are included--(1) flexibility - typical applications, (2) detailed engineering data, (3) accessories, (4) approvals, (5) guide specifications, (6) dimensional drawings of a typical unit, (7) blower data, (8) mounting data,…
OPTIMIZATION OF HIGH-SPEED GC/TOFMS FOR METHOD TO-14 ANALYSIS
A fast GC/MS system (FGCMS) consisting of a high-speed gas chromatograph equipped with a narrow bandwidth injection accessory and a time-of-flight mass spectrometer detector is being optimized for analysis of Method TO-14 target compounds. The system consists entirely of comm...
de Jong, Mark R; Hoogerwaard, Annemiek F; Gal, Pim; Adiyaman, Ahmet; Smit, Jaap Jan J; Delnoy, Peter Paul H M; Ramdat Misier, Anand R; van Hasselt, Boudewijn A A M; Heeg, Jan-Evert; le Polain de Waroux, Jean-Benoit; Lau, Elizabeth O Y; Staessen, Jan A; Persu, Alexandre; Elvan, Arif
2016-06-01
Blood pressure response to renal denervation is highly variable, and the proportion of responders is disappointing. This may be partly because of accessory renal arteries too small for denervation, causing incomplete ablation. Renal nerve stimulation before and after renal denervation is a promising approach to assess completeness of renal denervation and may predict blood pressure response to renal denervation. The objective of the current study was to assess renal nerve stimulation-induced blood pressure increase before and after renal sympathetic denervation in main and accessory renal arteries of anaesthetized patients with drug-resistant hypertension. The study included 21 patients. Nine patients had at least 1 accessory renal artery in which renal denervation was not feasible. Renal nerve stimulation was performed in the main arteries of all patients and in accessory renal arteries of 6 of 9 patients with accessory arteries, both before and after renal sympathetic denervation. Renal nerve stimulation before renal denervation elicited a substantial increase in systolic blood pressure, both in main (25.6±2.9 mm Hg; P<0.001) and accessory (24.3±7.4 mm Hg; P=0.047) renal arteries. After renal denervation, renal nerve stimulation-induced systolic blood pressure increase was blunted in the main renal arteries (Δ systolic blood pressure, 8.6±3.7 mm Hg; P=0.020), but not in the nondenervated renal accessory renal arteries (Δ systolic blood pressure, 27.1±7.6 mm Hg; P=0.917). This residual source of renal sympathetic tone may result in persistent hypertension after ablation and partly account for the large response variability. © 2016 American Heart Association, Inc.
MERS-CoV Accessory ORFs Play Key Role for Infection and Pathogenesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menachery, Vineet D.; Mitchell, Hugh D.; Cockrell, Adam S.
ABSTRACT While dispensable for viral replication, coronavirus (CoV) accessory open reading frame (ORF) proteins often play critical roles during infection and pathogenesis. Utilizing a previously generated mutant, we demonstrate that the absence of all four Middle East respiratory syndrome CoV (MERS-CoV) accessory ORFs (deletion of ORF3, -4a, -4b, and -5 [dORF3-5]) has major implications for viral replication and pathogenesis. Importantly, attenuation of the dORF3-5 mutant is primarily driven by dysregulated host responses, including disrupted cell processes, augmented interferon (IFN) pathway activation, and robust inflammation.In vitroreplication attenuation also extends toin vivomodels, allowing use of dORF3-5 as a live attenuated vaccine platform.more » Finally, examination of ORF5 implicates a partial role in modulation of NF-κB-mediated inflammation. Together, the results demonstrate the importance of MERS-CoV accessory ORFs for pathogenesis and highlight them as potential targets for surveillance and therapeutic treatments moving forward. IMPORTANCEThe initial emergence and periodic outbreaks of MERS-CoV highlight a continuing threat posed by zoonotic pathogens to global public health. In these studies, mutant virus generation demonstrates the necessity of accessory ORFs in regard to MERS-CoV infection and pathogenesis. With this in mind, accessory ORF functions can be targeted for both therapeutic and vaccine treatments in response to MERS-CoV and related group 2C coronaviruses. In addition, disruption of accessory ORFs in parallel may offer a rapid response platform to attenuation of future emergent strains based on both SARS- and MERS-CoV accessory ORF mutants.« less
21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...
Analyzing planetary transits with a smartphone
NASA Astrophysics Data System (ADS)
Barrera-Garrido, Azael
2015-03-01
Today's smartphones are getting more sensors than ever as factory-installed accessories. The time when a luxury mobile phone had only vertical and GPS sensors is gone. New smartphones come equipped with multiple sensors for many physical parameters. Smartphones are becoming portable physics laboratory data loggers for a variety of measurements in mechanics, thermodynamics, electromagnetism, and optics. All sorts of possibilities are now open, provided their sensors are calibrated. Many examples using the sensors available in smartphones have been presented, mostly in this column and a few other publications, such as acceleration sensors,1-3 microphones,4,5 camera,6-8 and light sensors.9,10
Neuromuscular ultrasound of cranial nerves.
Tawfik, Eman A; Walker, Francis O; Cartwright, Michael S
2015-04-01
Ultrasound of cranial nerves is a novel subdomain of neuromuscular ultrasound (NMUS) which may provide additional value in the assessment of cranial nerves in different neuromuscular disorders. Whilst NMUS of peripheral nerves has been studied, NMUS of cranial nerves is considered in its initial stage of research, thus, there is a need to summarize the research results achieved to date. Detailed scanning protocols, which assist in mastery of the techniques, are briefly mentioned in the few reference textbooks available in the field. This review article focuses on ultrasound scanning techniques of the 4 accessible cranial nerves: optic, facial, vagus and spinal accessory nerves. The relevant literatures and potential future applications are discussed.
Quantitative Hydrocarbon Surface Analysis
NASA Technical Reports Server (NTRS)
Douglas, Vonnie M.
2000-01-01
The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.
Accessory Muscles of the Extremities.
Vanhoenacker, Filip M; Desimpel, Julie; Mespreuve, Marc; Tagliafico, Alberto
2018-07-01
Accessory muscles and variations are not uncommon at the upper and lower extremity. They are often overlooked because they are asymptomatic and present as incidental findings on imaging. However, they may present as a soft tissue swelling, thereby mimicking soft tissue tumors. Other symptoms are attributed to impingement on neurovascular structures and to exercise-related pain. Thorough knowledge of the anatomy, systematic imaging analysis, and the awareness of it are the clues to correct identification. On ultrasound, accessory muscles have a similar echotexture as other muscles, whereas the signal intensity on magnetic resonance imaging (MRI) is similar to muscle. Because of the intrinsic contrast with the adjacent intermuscular fat, accessory muscles are best depicted on MRI without fat suppression. This article provides a short overview of the anatomy of most prevalent accessory muscles of the upper and lower limb and its potential pathogenic nature. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Yuan, Yuan; Long, Deyong; Dong, Jianzeng; Tao, Ling; Ma, Changsheng
2017-12-01
We report a case of a patient with right axillary ventricular. Similar congenital anomaly of the right atrium was reported as "right appendage diverticulum or right atrial diverticulum." However, this independent chamber has its own annulus, synchronizes with the right ventricular, and generates large ventricular potential. Under the guidance of the CARTO mapping system (Biosense Webster, Diamond Bar, CA, USA), a right atrioventricular accessory pathway associated with type B Wolff-Parkinson-White syndrome was ablated successfully. This pathway was close to the annulus of the axillary ventricular. The patient remained free of arrhythmia at 1-year follow-up. © 2017 Wiley Periodicals, Inc.
Simplified human model and pedestrian simulation in the millimeter-wave region
NASA Astrophysics Data System (ADS)
Han, Junghwan; Kim, Seok; Lee, Tae-Yun; Ka, Min-Ho
2016-02-01
The 24 GHz and 77 GHz radar sensors have been studied as a strong candidate for advanced driver assistance systems(ADAS) because of their all-weather capability and accurate range and radial velocity measuring scheme. However, developing a reliable pedestrian recognition system hasmany obstacles due to the inaccurate and non-trivial radar responses at these high frequencies and the many combinations of clothes and accessories. To overcome these obstacles, many researchers used electromagnetic (EM) simulation to characterize the radar scattering response of a human. However, human simulation takes so long time because of the electrically huge size of a human in the millimeter-wave region. To reduce simulation time, some researchers assumed the skin of a human is the perfect electric conductor (PEC) and have simulated the PEC human model using physical optics (PO) algorithm without a specific explanation about how the human body could be modeled with PEC. In this study, the validity of the assumption that the surface of the human body is considered PEC in the EM simulation is verified, and the simulation result of the dry skin human model is compared with that of the PEC human model.
21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...
21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...
21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...
21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Instrumentation and Accessories § 864.3260 OTC test sample collection systems for drugs of abuse testing. (a) Identification. An over-the-counter (OTC) test sample collection system for drugs of abuse testing is a device...
Özyurt, Nurcan; Candan, Selami; Suludere, Zekiye
2013-01-01
The male reproductive system of Dolycoris baccarum (Linnaeus 1758) is studied morphologically and histologically using both light and scanning electron microscopes (SEM). The reproductive system of the male D. baccarum consists of a pair of testis, a pair of vas deferens, a pair of seminal vesicles, accessory glands (mesadenia, ectadenia), a bulbus ejaculatorius, a pair of ectodermal sacs, and a ductus ejaculatorius. The number of testicular follicles varies from four to six. The testicular follicles have three different development zones (growth zone, maturation zone, differentiation zone). The testes are connected to the seminal vesicles by the vas deferens. Vas deferens and seminal vesicles, which are fine-long and cylindrical. The seminal vesicle is connected with bulbus ejaculatorius which is balloon-shaped and surrounded with accessory glands. The bulbus ejaculatorius is continuous with ductus ejaculatorius which connected to the aedeagus. Copyright © 2012 Elsevier Ltd. All rights reserved.
Felix, Valtuir Barbosa; Dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; Dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado
2016-01-01
The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel's topography. In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.
Bertazzoni, Stefania; Williams, Angela; Jones, Darcy A B; Syme, Robert A; Tan, Kar-Chun; Hane, James Kyawzwar
2018-04-17
Fungal pathogen genomes can often be divided into core and accessory regions. Accessory regions may be comprised of either accessory regions (ARs) within core chromosomes (CCs), or wholly-dispensable (accessory) chromosomes (ACs). Fungal ACs and ARs typically accumulate mutations and structural rearrangements more rapidly over time than CCs, and many harbour genes relevant to host-pathogen interactions. These regions are of particular interest in plant pathology and include host-specific virulence factors and secondary metabolite synthesis gene clusters. This review outlines known ACs and ARs in fungal genomes, methods used for their detection, their common properties that differentiate them from the core genome, and what is currently known of their various roles in pathogenicity. Reports on the evolutionary processes generating and shaping AC/AR compartments are discussed, including repeat induced point mutation (RIP) and breakage-fusion-bridge (BFB) cycles. Previously ACs have been studied extensively within key genera including Fusarium, Zymoseptoria and Alternaria, but are growing in their frequency of observation and perceived importance across a wider range of fungal species. Recent advances in sequencing technologies permit affordable genome assembly and re-sequencing of populations that will facilitate further discovery and routine screening of ACs.
A Study of Evaluation and Management of Rare Congenital Breast Diseases
Mehta, Sudhir Kumar; Bala, Jyoti; Zaman, Muzzafar; Mittal, Amit; Gupta, Guarav; Rudra, Samer; Singal, Samita
2016-01-01
Introduction Polymastia and polythelia may be asymptomatic or cause pain, restriction of arm movement, milk discharge, cosmetic problems or anxiety. Cosmesis is the main indication for surgical excision of accessory breasts in axilla. In addition it also confirms the diagnosis and allays the patient’s fear of harbouring a malignancy. Aim To evaluate the presentation of symptoms, investigations required for diagnosis and the management to improve the treatment protocols in patients with breast diseases. Materials and Methods This retrospective study on breast diseases presenting as supernumerary breasts and nipples was conducted in the Department of Surgery between January 2013 and January 2016 at MMIMS Research and hospital, Mullana, Ambala. Patients were evaluated for breast diseases, either benign or malignant in both genders. A total of 32 cases diagnosed as accessory breasts disease were retrieved from the hospital archive. The clinical and radiological evaluation was done in the form of ultrasound and mammography wherever necessary. Accessory breast tissues were excised under general anesthesia and histopathological examinations were done. Results Out of 32 cases: 1(3.125%) male patient had unilateral and 1(3.125%) male had bilateral accessory nipple, 7 (21.87%) females had unilateral and 1(3.125%) had bilateral accessory nipple, 1 (3.125%) diagnosed as accessory axillary fibroadenoma in female, 16(50%) presented as unilateral and 5 (15.62%) had bilateral swelling in the axilla as accessory breast. Patients underwent surgical excision and in 8(25%) cases z- shaped incision was made in view of better cosmesis. Patients were followed up upto 6 months postoperatively. There were no residual swelling and movements of the arm over the shoulder joint were normal. In 3(9.37%) cases, wound dehiscence occurred; in 2 (6.25%) cases lymphoedema formation was seen. These were successfully managed conservatively. Conclusion As breast swellings either fibroadenoma or carcinoma are common entities to come across everywhere but accessory breasts are rarely encountered especially in rural areas because of less awareness. The study found that there was tendency to neglect the swelling as there were minimal symptoms present. We also came across a rare entity, accessory breast and accessory nipples. A clinician should not ignore such cases taking as simple swelling because of chances of discovering a malignancy can occur. PMID:27891392
A Study of Evaluation and Management of Rare Congenital Breast Diseases.
Singal, Rikki; Mehta, Sudhir Kumar; Bala, Jyoti; Zaman, Muzzafar; Mittal, Amit; Gupta, Guarav; Rudra, Samer; Singal, Samita
2016-10-01
Polymastia and polythelia may be asymptomatic or cause pain, restriction of arm movement, milk discharge, cosmetic problems or anxiety. Cosmesis is the main indication for surgical excision of accessory breasts in axilla. In addition it also confirms the diagnosis and allays the patient's fear of harbouring a malignancy. To evaluate the presentation of symptoms, investigations required for diagnosis and the management to improve the treatment protocols in patients with breast diseases. This retrospective study on breast diseases presenting as supernumerary breasts and nipples was conducted in the Department of Surgery between January 2013 and January 2016 at MMIMS Research and hospital, Mullana, Ambala. Patients were evaluated for breast diseases, either benign or malignant in both genders. A total of 32 cases diagnosed as accessory breasts disease were retrieved from the hospital archive. The clinical and radiological evaluation was done in the form of ultrasound and mammography wherever necessary. Accessory breast tissues were excised under general anesthesia and histopathological examinations were done. Out of 32 cases: 1(3.125%) male patient had unilateral and 1(3.125%) male had bilateral accessory nipple, 7 (21.87%) females had unilateral and 1(3.125%) had bilateral accessory nipple, 1 (3.125%) diagnosed as accessory axillary fibroadenoma in female, 16(50%) presented as unilateral and 5 (15.62%) had bilateral swelling in the axilla as accessory breast. Patients underwent surgical excision and in 8(25%) cases z- shaped incision was made in view of better cosmesis. Patients were followed up upto 6 months postoperatively. There were no residual swelling and movements of the arm over the shoulder joint were normal. In 3(9.37%) cases, wound dehiscence occurred; in 2 (6.25%) cases lymphoedema formation was seen. These were successfully managed conservatively. As breast swellings either fibroadenoma or carcinoma are common entities to come across everywhere but accessory breasts are rarely encountered especially in rural areas because of less awareness. The study found that there was tendency to neglect the swelling as there were minimal symptoms present. We also came across a rare entity, accessory breast and accessory nipples. A clinician should not ignore such cases taking as simple swelling because of chances of discovering a malignancy can occur.
Spectroscopic characterization of PET glycolysis and surface molecular orientation of polymers
NASA Astrophysics Data System (ADS)
Weir, Michael David
This dissertation seeks to develop novel polymer characterization techniques using UV and fluorescence spectroscopy. The first portion of the dissertation consists of monitoring the glycolytic depolymerization of poly(ethylene terephthalate), PET, using UV and fluorescence spectroscopy. The primary product of the glycolysis of PET is bis(hydroxyethyl) tereplithalate (BHET), along with other low molecular weight oligomers (degree of polymerization = 1--3). The UV absorption of the glycolized products occurs at 287 nm and is associated with the pi → pi* transition of the tereplithalate moiety. This absorption band shows a linear increase with reaction time that corresponds to an increase in the concentration of glycolized products. BHET was selected as a model compound to represent the glycolized products and was used to calculate the concentration of glycolized products. When using excitation wavelengths of 300 nm and 340 nm, fluorescence emission spectra of the glycolized products were observed at 350 nm and 380 nm respectively. These emission bands also showed an increase in intensity corresponding to the concentration increase. Again, BHET was used as a model compound to simulate and calculate the concentration of the glycolized products. We determined the overall reaction to be second order and that the reaction rate is strongly dependent on the glycol concentration; an increase in the glycol concentration results in an increase in the reaction rate. The second portion of this dissertation consists of the characterization of surface molecular orientation of poly(ethylene terephthalate) (PET) and Kaptono films by UV reflection dichroism using a specular reflection accessory and a bifurcated fiber optic. The UV reflection peaks for PET and Kapton RTM occur at 257 nm and 310 nm respectively. The orientation function and dichroic ratio calculated using both specular reflection and the fiber optic agreed well with each other. Additionally, correct placement of the polarizer is essential in producing good results. When placed at either the source or detector side of the fiber, there was no evidence of orientation seen. However, placement at the common end shows good agreement with the results from the specular reflection accessory. These different results are a manifestation of the polarization/depolarization characteristics of the fiber optic.
The development of the olfactory organs in newly hatched monotremes and neonate marsupials
Schneider, Nanette Yvette
2011-01-01
Olfactory cues are thought to play a crucial role in the detection of the milk source at birth in mammals. It has been shown that a marsupial, the tammar wallaby, can detect olfactory cues from its mother's pouch at birth. This study investigates whether the main olfactory and accessory olfactory system are similarly well developed in other marsupials and monotremes at birth/hatching as in the tammar. Sections of the head of various marsupial and two monotreme species were investigated by light microscopy. Both olfactory systems were less well developed in the kowari and Eastern quoll. No olfactory or vomeronasal or terminal nerves could be observed; the main olfactory bulb (MOB) had only two layers while no accessory olfactory bulb or ganglion terminale were visible. All other investigated marsupials and monotremes showed further developed olfactory systems with olfactory, vomeronasal and terminal nerves, a three-layered MOB, and in the marsupials a prominent ganglion terminale. The main olfactory system was further developed than the accessory olfactory system in all species investigated. The olfactory systems were the least developed in species in which the mother's birth position removed most of the difficulty in reaching the teat, placing the neonate directly in the pouch. In monotremes they were the furthest developed as Bowman glands were found underlying the main olfactory epithelium. This may reflect the need to locate the milk field each time they drink as they cannot permanently attach to it, unlike therian mammals. While it still needs to be determined how an odour signal could be further processed in the brain, this study suggests that marsupials and monotremes possess well enough developed olfactory systems to be able to detect an odour cue from the mammary area at birth/hatching. It is therefore likely that neonate marsupials and newly hatched monotremes find their way to the milk source using olfactory cues, as has been previously suggested for the marsupial tammar wallaby, rabbits, rats and other eutherians. PMID:21592102
2016-02-12
The Food and Drug Administration (FDA) is issuing a final order to redesignate membrane lung devices for long-term pulmonary support, a preamendments class III device, as extracorporeal circuit and accessories for long-term respiratory/cardiopulmonary failure, and to reclassify the device to class II (special controls) in patients with acute respiratory failure or acute cardiopulmonary failure where other available treatment options have failed, and continued clinical deterioration is expected or the risk of death is imminent. A membrane lung device for long-term pulmonary support (>6 hours) refers to the oxygenator in an extracorporeal circuit used during long-term procedures, commonly referred to as extracorporeal membrane oxygenation (ECMO). Because a number of other devices and accessories are used with the oxygenator in the circuit, the title and identification of the regulation are revised to include extracorporeal circuit and accessories for long-term respiratory/cardiopulmonary failure. Although an individual device or accessory used in an ECMO circuit may already have its own classification regulation when the device or accessory is intended for short-term use (<=6 hours), such device or accessory will be subject to the same regulatory controls applied to the oxygenator (i.e., class II, special controls) when evaluated as part of the ECMO circuit for long-term use (>6 hours). On its own initiative, based on new information, FDA is revising the classification of the membrane lung device for long-term pulmonary support.
Miyamoto, Wataru; Takao, Masato; Yamada, Kazuaki; Yasui, Youichi; Matsushita, Takashi
2012-10-01
To examine the effectiveness of a new technique for reattaching the posterior tibial tendon (PTT) using a bone tunnel and interference screw after resection of the accessory navicular for painful accessory navicular (type II) in adult athletes. Ten adult athletes (7 male, 3 female; mean age 30 years, range 23-45) underwent reconstruction using a bone tunnel with an interference screw for a painful accessory navicular. All patients complained of pain on the medial aspect of the foot after eversion sprain during sports activities and radiographs revealed type II accessory navicular. Clinical evaluation with the American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale (AOFAS) and visual analogue scale (VAS) before surgery was compared with that at most recent follow up (mean 30 months, range 24-39). Mean AOFAS score improved from a preoperative 62.8 ± 2.9 points (range 61-82) to a postoperative 92.1 ± 7.0 points (range 83-100; p < 0.01). Furthermore, mean VAS score improved from a preoperative 92.5 ± 5.4 points (range 85-100) to a postoperative 4.5 ± 3.8 points (range 0-10; p < 0.01). All patients could return to full sports activity at a mean of 14 weeks (range 12-18) after surgery. The presented technique reconstructs the bone-tendon interface of the PTT at the primary navicular with sufficient fixation after resection of the accessory navicular, which preserves the strength of the PTT in adult athletes with an intractably painful accessory navicular.
Accessory stimulus modulates executive function during stepping task
Watanabe, Tatsunori; Koyama, Soichiro; Tanabe, Shigeo
2015-01-01
When multiple sensory modalities are simultaneously presented, reaction time can be reduced while interference enlarges. The purpose of this research was to examine the effects of task-irrelevant acoustic accessory stimuli simultaneously presented with visual imperative stimuli on executive function during stepping. Executive functions were assessed by analyzing temporal events and errors in the initial weight transfer of the postural responses prior to a step (anticipatory postural adjustment errors). Eleven healthy young adults stepped forward in response to a visual stimulus. We applied a choice reaction time task and the Simon task, which consisted of congruent and incongruent conditions. Accessory stimuli were randomly presented with the visual stimuli. Compared with trials without accessory stimuli, the anticipatory postural adjustment error rates were higher in trials with accessory stimuli in the incongruent condition and the reaction times were shorter in trials with accessory stimuli in all the task conditions. Analyses after division of trials according to whether anticipatory postural adjustment error occurred or not revealed that the reaction times of trials with anticipatory postural adjustment errors were reduced more than those of trials without anticipatory postural adjustment errors in the incongruent condition. These results suggest that accessory stimuli modulate the initial motor programming of stepping by lowering decision threshold and exclusively under spatial incompatibility facilitate automatic response activation. The present findings advance the knowledge of intersensory judgment processes during stepping and may aid in the development of intervention and evaluation tools for individuals at risk of falls. PMID:25925321
Rock, K L
1982-10-01
A model of accessory cell-dependent lectin-mediated T cell activation was investigated by utilizing a mitogen-inducible T cell hybridoma. A continuous MHC-restricted antigen-specific T cell line was fused with the azaguanine-resistant AKR thymoma BW5147. A hybrid, RF1.16B, was identified that is minimally inducible by Con A stimulation alone but is stimulated by Con A in the presence of T cell-depleted accessory cells to produce interleukin 2. The accessory cell function can be replaced by the monokine interleukin 1. Thus the lectin is a sufficient trigger for the hybrid in the absence of MHC restriction elements. The accessory cell function from splenocytes is provided by a non-B, non-T, predominantly Ia-bearing radioresistant cell. The interaction between the RF1.16B hybrid and the accessory cell population is not H-2-restricted. Control experiments, including the use of a cloned source of accessory cells, ruled out contaminating T cells or direct lectin effects as an explanation for the lack of H-2 restriction. The finding that an Ia-bearing cell is required for activation in an MHC-nonrestricted manner is discussed, and a hypothesis is raised that Ia antigens may play a role in addition to that of being a restriction element.
Kang, Ningdong; Baum, Michael J.; Cherry, James A.
2009-01-01
The main olfactory system, like the accessory olfactory system, responds to pheromones involved in social communication. Whereas pheromones detected by the accessory system are transmitted to the hypothalamus via the medial (‘vomeronasal’) amygdala, the pathway by which pheromones are detected and transmitted by the main system is not well understood. We examined in female mice whether a direct projection from mitral/tufted (M/T) cells in the main olfactory bulb (MOB) to the medial amygdala exists, and whether medial amygdala-projecting M/T cells are activated by volatile urinary odors from conspecifics or a predator (cat). Simultaneous anterograde tracing using Phaseolus vulgaris leucoagglutinin and Fluoro-Ruby placed in the MOB and accessory olfactory bulb (AOB), respectively, revealed that axons of MOB M/T cells projected to superficial laminae of layer Ia in anterior and posterodorsal subdivisions of the medial amygdala, whereas projection neurons from the AOB sent axons to non-overlapping, deeper layer Ia laminae of the same subdivisions. Placement of the retrograde tracer cholera toxin B into the medial amygdala labeled M/T cells that were concentrated in the ventral MOB. Urinary volatiles from male mice, but not from female conspecifics or cat, induced Fos in medial amygdala-projecting MOB M/T cells of female subjects, suggesting that information about male odors is transmitted directly from the MOB to the ‘vomeronasal’ amygdala. The presence of a direct MOB-to-medial amygdala pathway in mice and other mammals could enable volatile, opposite-sex pheromones to gain privileged access to diencephalic structures that control mate recognition and reproduction. PMID:19187265
Spiegel, Carolina N; Bretas, Jorge A C; Peixoto, Alexandre A; Vigoder, Felipe M; Bruno, Rafaela V; Soares, Maurilio J
2013-01-01
The male reproductive system of insects can have several tissues responsible for the secretion of seminal fluid proteins (SFPs), such as testes, accessory glands, seminal vesicles, ejaculatory duct and ejaculatory bulb. The SFPs are transferred during mating and can induce several physiological and behavioral changes in females, such as increase in oviposition and decrease in sexual receptivity after copulation. The phlebotomine Lutzomyia longipalpis is the main vector of visceral leishmaniasis. Despite its medical importance, little is known about its reproductive biology. Here we present morphological aspects of the male L. longipalpis reproductive system by light, scanning and transmission electron microscopy, and compare the mating frequency of both virgin and previously mated females. The male L. longipalpis reproductive system is comprised by a pair of oval-shaped testes linked to a seminal vesicle by vasa deferentia. It follows an ejaculatory duct with an ejaculatory pump (a large bulb enveloped by muscles and associated to tracheas). The terminal endings of the vasa deferentia are inserted into the seminal vesicle by invaginations of the seminal vesicle wall, which is composed by a single layer of gland cells, with well-developed endoplasmic reticulum profiles and secretion granules. Our data suggest that the seminal vesicle acts both as a spermatozoa reservoir and as an accessory gland. Mating experiments support this hypothesis, revealing a decrease in mating frequency after copulation that indicates the effect of putative SFPs. Ultrastructural features of the L. longipalpis male seminal vesicle indicated its possible role as an accessory gland. Behavioral observations revealed a reduction in mating frequency of copulated females. Together with transcriptome analyses from male sandfly reproductive organs identifying ESTs encoding orthologs of SFPs, these data indicate the presence of putative L. longipalpis SFPs reducing sexual mating frequency of copulated females.
26 CFR 48.4061(a)-4 - Parts or accessories sold on or in connection with chasis, bodies, etc.
Code of Federal Regulations, 2011 CFR
2011-04-01
... with chasis, bodies, etc. 48.4061(a)-4 Section 48.4061(a)-4 Internal Revenue INTERNAL REVENUE SERVICE... Parts or accessories sold on or in connection with chasis, bodies, etc. (a) In general. The tax attaches... parts or accessories which are not sold on or in connection with the sale of a taxable chassis, body, or...
26 CFR 48.4061(a)-4 - Parts or accessories sold on or in connection with chasis, bodies, etc.
Code of Federal Regulations, 2010 CFR
2010-04-01
... with chasis, bodies, etc. 48.4061(a)-4 Section 48.4061(a)-4 Internal Revenue INTERNAL REVENUE SERVICE... Parts or accessories sold on or in connection with chasis, bodies, etc. (a) In general. The tax attaches... parts or accessories which are not sold on or in connection with the sale of a taxable chassis, body, or...
Lateral Knee Compartment Portals: A Cadaveric Study Defining a Posterolateral Viewing Safety Zone.
Dilworth, Brian; Fehrenbacher, Victor; Nyland, John; Clark, Jamie; Greene, Joseph W
2018-04-12
This study attempted to define a reproducible "safe zone" based on extra- and intra-articular knee anatomy for placing one or 2 accessory portals in the lateral tibiofemoral compartment for posterolateral region viewing. Standard portals were created in 10 cadaveric knees to enable posterolateral region arthroscopic lateral tibiofemoral joint compartment viewing. After identifying the lateral knee surface tissue "soft spot," an accessory posterolateral portal (A) was created using an 18-gauge spinal needle and 4-mm cannula under direct visualization of a 70° arthroscope through the anteromedial portal. A second accessory portal (B) was then created 1 cm posterior and 1 cm superior to portal A. Accessory portal locations were measured relative to capsular fold and popliteus tendon locations. Distances from the peroneal nerve, lateral collateral ligament, popliteus tendon, and the biceps tendon were determined. Statistical analysis compared portal location differences from key anatomical structures (P < .05). Accessory portal A (mean ± 95% confidence interval) was located 8.8 ± 2.7 mm from the popliteus tendon, 11.6 ± 2.7 mm from the lateral collateral ligament (LCL), 26.8 ± 2.3 mm from the peroneal nerve, and 4.9 ± 2.5 mm from the biceps tendon. Accessory portal B was located 17.3 ± 2.8 mm from the popliteus tendon, 20 ± 2.8 mm from the LCL, 30.3 ± 3.3 mm from the peroneal nerve, and 7.0 ± 4.8 mm from the biceps tendon. Accessory portal B was located a greater distance from the LCL and the popliteus tendon than portal A (P < .0001). Using intra- and extra-articular anatomic landmarks, both accessory portals could be safely placed in the lateral tibiofemoral joint compartment to enable posterolateral region viewing. Accessory portals used individually or in combination may enable easier posterolateral region viewing for arthroscopic repair of lateral tibiofemoral compartment structures. Lateral tibiofemoral compartment portals can be safely created to enable improved visibility for complex arthroscopic procedures in the posterolateral viewing region. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
14 CFR 23.1091 - Air induction system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and their accessories must supply the air required by that engine and auxiliary power unit and their... cowling if the emergence of backfire flames will result in a hazard. (3) The supplying of air to the engine through the alternate air intake system may not result in a loss of excessive power in addition to...
A portable, low-cost flight-data measurement and recording system
NASA Technical Reports Server (NTRS)
Miller, R. J.
1982-01-01
The design of and the experience with an inexpensive, hand-portable, onboard data system used to record four parameters in the final portion of the landing approach and touchdown of an airplane are described. The system utilized a high-quality audio tape recorder and amateur photographic equipment with accessory circuitry rather than specialized instrumentation to given satisfactory results.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-18
..., Inc. (Takata), and Iteris, Inc. (Iteris) to mount lane departure warning system sensors lower in the... allow it to install lane departure warning system sensors on 1,272 of its newly purchased power units... system sensors on December 15, 2009 and on February 25, 2010, respectively. On June 14, 2010, FMCSA...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-14
...), and Iteris, Inc. (Iteris) regarding the placement of lane departure warning system sensors at the top... mounting of the lane departure warning system sensors near the top of the windshield, and within the swept... departure warning system would be used to alert a driver when he or she unintentionally drifts out of their...
Electrophysiological mapping of the accessory olfactory bulb of the rabbit (Oryctolagus cuniculus).
van Groen, T; Ruardy, L; da Silva, F H
1986-07-01
Field potentials elicited by electrical stimulation of the vomeronasal nerve were measured in the accessory olfactory bulb of the rabbit. Maps were made of the distribution of surface field potentials and of the corresponding depth profiles. The surface maps followed closely the contours of the accessory olfactory bulb: at the frontal border the field potential tended to zero and at the center of the structure the field potential attained a maximum. Depth profiles of the field potentials through the accessory olfactory bulb presented a surface-negative wave and, in depth, a positive wave. The polarity reversal occurred at the deep part of the granule cell layer. The zero equipotential line followed closely the curvature of the granule cell layer. Current source density analysis of the depth profiles revealed a main sink at the external plexiform and granule cell layers. This indicates that the main activity in the accessory olfactory bulb is generated by the synapses between the mitral cells and the granule cells as is found in the main olfactory bulb.
Electronic Position Sensor for Power Operated Accessory
Haag, Ronald H.; Chia, Michael I.
2005-05-31
An electronic position sensor for use with a power operated vehicle accessory, such as a power liftgate. The position sensor includes an elongated resistive circuit that is mounted such that it is stationary and extends along the path of a track portion of the power operated accessory. The position sensor further includes a contact nub mounted to a link member that moves within the track portion such that the contact nub is slidingly biased against the elongated circuit. As the link member moves under the force of a motor-driven output gear, the contact nub slides along the surface of the resistive circuit, thereby affecting the overall resistance of the circuit. The position sensor uses the overall resistance to provide an electronic position signal to an ECU, wherein the signal is indicative of the absolute position of the power operated accessory. Accordingly, the electronic position sensor is capable of providing an electronic signal that enables the ECU to track the absolute position of the power operated accessory.
Complete Spinal Accessory Nerve Palsy From Carrying Climbing Gear.
Coulter, Jess M; Warme, Winston J
2015-09-01
We report an unusual case of spinal accessory nerve palsy sustained while transporting climbing gear. Spinal accessory nerve injury is commonly a result of iatrogenic surgical trauma during lymph node excision. This particular nerve is less frequently injured by blunt trauma. The case reported here results from compression of the spinal accessory nerve for a sustained period-that is, carrying a load over the shoulder using a single nylon rope for 2.5 hours. This highlights the importance of using proper load-carrying equipment to distribute weight over a greater surface area to avoid nerve compression in the posterior triangle of the neck. The signs and symptoms of spinal accessory nerve palsy and its etiology are discussed. This report is particularly relevant to individuals involved in mountaineering and rock climbing but can be extended to anyone carrying a load with a strap over one shoulder and across the body. Copyright © 2015 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Accessory proteins of SARS-CoV and other coronaviruses.
Liu, Ding Xiang; Fung, To Sing; Chong, Kelvin Kian-Long; Shukla, Aditi; Hilgenfeld, Rolf
2014-09-01
The huge RNA genome of SARS coronavirus comprises a number of open reading frames that code for a total of eight accessory proteins. Although none of these are essential for virus replication, some appear to have a role in virus pathogenesis. Notably, some SARS-CoV accessory proteins have been shown to modulate the interferon signaling pathways and the production of pro-inflammatory cytokines. The structural information on these proteins is also limited, with only two (p7a and p9b) having their structures determined by X-ray crystallography. This review makes an attempt to summarize the published knowledge on SARS-CoV accessory proteins, with an emphasis on their involvement in virus-host interaction. The accessory proteins of other coronaviruses are also briefly discussed. This paper forms part of a series of invited articles in Antiviral Research on "From SARS to MERS: 10 years of research on highly pathogenic human coronaviruses" (see Introduction by Hilgenfeld and Peiris (2013)). Copyright © 2014 Elsevier B.V. All rights reserved.
Visual and auditory accessory stimulus offset and the Simon effect.
Nishimura, Akio; Yokosawa, Kazuhiko
2010-10-01
We investigated the effect on the right and left responses of the disappearance of a task-irrelevant stimulus located on the right or left side. Participants pressed a right or left response key on the basis of the color of a centrally located visual target. Visual (Experiment 1) or auditory (Experiment 2) task-irrelevant accessory stimuli appeared or disappeared at locations to the right or left of the central target. In Experiment 1, responses were faster when onset or offset of the visual accessory stimulus was spatially congruent with the response. In Experiment 2, responses were again faster when onset of the auditory accessory stimulus and the response were on the same side. However, responses were slightly slower when offset of the auditory accessory stimulus and the response were on the same side than when they were on opposite sides. These findings indicate that transient change information is crucial for a visual Simon effect, whereas sustained stimulation from an ongoing stimulus also contributes to an auditory Simon effect.
Strauß, Johannes; Riesterer, Anja S; Lakes-Harlan, Reinhard
2016-01-01
The subgenual organ and associated scolopidial organs are well studied in Orthoptera and related taxa. In some insects, a small accessory organ or Nebenorgan is described posterior to the subgenual organ. In Tettigoniidae (Ensifera), the accessory organ has only been noted in one species though tibial sensory organs are well studied for neuroanatomy and physiology. Here, we use axonal tracing to analyse the posterior subgenual organ innervated by the main motor nerve. Investigating seven species from different groups of Tettigoniidae, we describe a small group of scolopidial sensilla (5-9 sensory neurons) which has features characteristic of the accessory organ: posterior tibial position, innervation by the main leg nerve rather than by the tympanal nerve, orientation of dendrites in proximal or ventro-proximal direction in the leg, and commonly association with a single campaniform sensillum. The neuroanatomy is highly similar between leg pairs. We show differences in the innervation in two species of the genus Poecilimon as compared to the other species. In Poecilimon, the sensilla of the accessory organ are innervated by one nerve branch together with the subgenual organ. The results suggest that the accessory organ is part of the sensory bauplan in the leg of Tettigoniidae and probably Ensifera. Copyright © 2015 Elsevier Ltd. All rights reserved.
Felix, Valtuir Barbosa; dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado
2016-01-01
Abstract Background The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. Objectives The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel’s topography. Methods In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. Results The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Conclusions Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.
Ito, Tadahiko; Okubo, Tadashi
2002-12-01
A female neonate with mitral stenosis due to accessory mitral valve with ventricular septal defect and patent ductus arteriosus is described. She was referred to our hospital because of neonatal asphyxia. Asphyxia was improved by ventilator support, but rapid deterioration of respiration with pulmonary congestion and hemorrhage appeared 8 days after birth. Echocardiography revealed an accessory mitral valve attached to the anterior mitral leaflet with a perimembranous ventricular septal defect and patent ductus arteriosus. Although there were no echocardiographical findings indicating mitral stenosis on admission, the mitral stenosis blood flow patterns were detected by color and pulsed Doppler examination performed on the eighth day after admission. Transaortic resection of accessory mitral valve tissue was performed with patch closure of the ventricular septal defect and ligation of the ductus arteriosus 35 days after birth. After operation, pulmonary congestion and hemorrhage were improved. Postoperative echocardiography showed complete resection of the accessory mitral valve and no mitral insufficiency. We concluded that the combination of the accessory mitral valve and left-to-right shunt due to ventricular septal defect or patent ducturs arteriosus might have led to a critical hemodynamic condition due to relative mitral stenosis in the neonatal period with the decrease in pulmonary vascular resistance.
Effect of the surface roughness on interfacial breakdown between two dielectric surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fournier, D.
1996-12-31
Cable splices and accessories are the weak link in an underground power distribution system. Investigations of problems related to cable splices and accessories becomes quite intricate once the simpler causes of failures are dismissed to allow more complex phenomena to be examined. The interfacial breakdown between two internal dielectric surfaces represents one of the major causes of failure for power cable joints. In order to better understand this phenomenon, breakdown experiments were performed at interfaces found in cable splices. An experimental jig was designed to induce breakdown between dielectric surfaces longitudinally along their interface. Effects of surface roughness at EPDM/XLPEmore » and EPDM/EPDM interfaces as well as the presence of silicone grease are taken into account.« less
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...), retractor, mechanical (noninflatable), snare, stylet, forceps, dissector, mechanical (noninflatable...
Raithel, Martin; Naegel, Andreas; Seidel, Sebastian; Raithel, Sandra; Diebel, Hiwot; Neurath, Markus F; Maiss, Juergen
2011-10-01
Prospective evaluation of the new 0.025 in. Visiglide(®) guidewire to facilitate endoscopic retrograde cholangiopancreaticography using the Olympus V-scope. Interventional endoscopic retrograde cholangiopancreaticography was performed in 9 patients with the Olympus V-scope and the 0.025 in. Visiglide(®) guidewire (VS group), whilst 9 other patients underwent endoscopic retrograde cholangiopancreaticography with a conventional Olympus duodenoscope using 0.035 in. conventional guidewires (controls). Exchange time of accessories, X-ray time, dose and endoscopic retrograde cholangiopancreaticography examination time were investigated. The VS group showed a significantly lower exchange time of endoscopic retrograde cholangiopancreaticography accessories (9; 4-10s, p<0.0001) than controls (29; 19-44s). The Visiglide(®) guidewire was complete fixable by the elevator in 35/36 instrument exchanges (97%) compared to 16/31 exchanges (52%) using conventional guidewires. Single-centre study, small patient numbers, two investigators. Endoscopic retrograde cholangiopancreaticography using the Olympus V-scope with the new 0.025 in. Visiglide(®) guidewire enables a 3-fold faster exchange of accessories due to a nearly complete fixation of the guidewire. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Friction Tests of a Chrysler 1978, 225 CID Engine
DOT National Transportation Integrated Search
1980-09-01
This document reports tests on a 1978 Chrysler, 225 CID, six-cylinder engine to determine the losses due to friction and accessories. The tests were conducted at the Automotive Research laboratory of the Transportation Systems Center with the engine ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
... sensors lower in the windshield of a commercial motor vehicle (CMV) than is currently permitted by the... departure warning system sensors on 1,272 of its newly purchased power units. Takata and Iteris submitted nearly identical exemption applications for their lane departure warning system sensors on December 15...
An Integrated Learning Approach to Teaching an Undergraduate Information Systems Course
ERIC Educational Resources Information Center
Riordan, Robert J.; Hine, Michael J.; Smith, Tim C.
2017-01-01
This paper describes the redesign and implementation of an introductory Information Systems class. The redesign was guided by principles drawn from the experiential and active learning literature. Central to the redesign are two simulated companies: petGRO, a fictional ERP-enabled pet food and accessories e-tailer, and beans4all, a technology…
Energy efficient engine. Core engine bearings, drives and configuration: Detailed design report
NASA Technical Reports Server (NTRS)
Broman, C. L.
1981-01-01
The detailed design of the forward and aft sumps, the accessory drive system, the lubrication system, and the piping/manifold configuration to be employed in the core engine test of the Energy Efficient Engine is addressed. The design goals for the above components were established based on the requirements of the test cell engine.
ERIC Educational Resources Information Center
Melichar, Joseph F.
Described as part of the Information System for Adaptive, Assistive and Recreational Equipment are equipment items for physically handicapped pupils in the functional areas of existence, equipment and adaptation. Reviewed in the existence section are such items as assistive food containers and container stabilizers, feeder accessories, bowel and…
High-precision double-frequency interferometric measurement of the cornea shape
NASA Astrophysics Data System (ADS)
Molebny, Vasyl V.; Pallikaris, Ioannis G.; Naoumidis, Leonidas P.; Smirnov, Eugene M.; Ilchenko, Leonid M.; Goncharov, Vadym O.
1996-11-01
To measure the shape of the cornea and its declinations from the necessary values before and after PRK operation, s well as the shape of other spherical objects like artificial pupil, a technique was used of double-frequency dual-beam interferometry. The technique is based on determination of the optical path difference between two neighboring laser beams, reflected from the cornea or other surface under investigation. Knowing the distance between the beams on the investigated shape. The shape itself is reconstructed by along-line integration. To adjust the wavefront orientation of the laser beam to the spherical shape of the cornea or artificial pupil in the course of scanning, additional lens is involved. Signal-to-noise ratio is ameliorated excluding losses in the acousto-optic deflectors. Polarization selection is realized for choosing the signal needed for measurement. 2D image presentation is accompanied by convenient PC accessories, permitting precise cross-section measurements along selected directions. Sensitivity of the order of 10-2 micrometers is achieved.
A combined method for correlative 3D imaging of biological samples from macro to nano scale
NASA Astrophysics Data System (ADS)
Kellner, Manuela; Heidrich, Marko; Lorbeer, Raoul-Amadeus; Antonopoulos, Georgios C.; Knudsen, Lars; Wrede, Christoph; Izykowski, Nicole; Grothausmann, Roman; Jonigk, Danny; Ochs, Matthias; Ripken, Tammo; Kühnel, Mark P.; Meyer, Heiko
2016-10-01
Correlative analysis requires examination of a specimen from macro to nano scale as well as applicability of analytical methods ranging from morphological to molecular. Accomplishing this with one and the same sample is laborious at best, due to deformation and biodegradation during measurements or intermediary preparation steps. Furthermore, data alignment using differing imaging techniques turns out to be a complex task, which considerably complicates the interconnection of results. We present correlative imaging of the accessory rat lung lobe by combining a modified Scanning Laser Optical Tomography (SLOT) setup with a specially developed sample preparation method (CRISTAL). CRISTAL is a resin-based embedding method that optically clears the specimen while allowing sectioning and preventing degradation. We applied and correlated SLOT with Multi Photon Microscopy, histological and immunofluorescence analysis as well as Transmission Electron Microscopy, all in the same sample. Thus, combining CRISTAL with SLOT enables the correlative utilization of a vast variety of imaging techniques.
One-man, self-contained CO2 concentrating system
NASA Technical Reports Server (NTRS)
Wynveen, R. A.; Schubert, F. H.; Powell, J. D.
1972-01-01
A program to design, fabricate, and test a 1-man, self-contained, electrochemical CO2 concentrating system is described. The system was designed with electronic controls and instrumentation to regulate performance, to analyze and display performance trends, and to detect and isolate faults. Ground support accessories were included to provide power, fluids, and a Parametric Data Display allowing real time indication of operating status in engineering units.
HIGH SPEED GC/MS FOR AIR ANALYSIS
A high speed GC/MS system consisting of a gas chromatograph equipped with a narrow bandwidth injection accessory and using a time-of-flight mass spectrometer detector has been adapted for analysis of ambient whole air samples which have been collected in passivated canisters. ...
Accessory Axillary Breast Excision with Liposuction Using Minimal Incision: A Preliminary Report.
Hwang, Seong Bae; Choi, Byung Seo; Byun, Geon Young; Koo, Bum Hwan; Lee, Sung Ryul
2017-02-01
Accessory breasts have received little attention in the surgical fields, although the condition is quite common in the female population, with 2-6% of women suffering from it. Its convexity and cyclic pain make women feel embarrassed and uncomfortable, so patients often desire surgical excision to improve their appearances and to remove the pain. A total of 967 patients who had been treated by an excision of accessory breast tissue with liposuction using minimal incision from September 2013 to Dec 2015 at the Damsoyu Hospital were analyzed for clinical factors retrospectively. All 967 patients were female. There were 514 (53.2%) unmarried patients and 453 (46.8%) married patients. The major clinical manifestation was the problem in the appearance with cyclic pain in both unmarried and married groups (82.7 vs. 87.9%). Three types of accessory breasts were observed: 779 (80.6%) breast tissue only in axillae, 182 (18.8%) breast tissue with accessory nipple, and 6 (0.6%) breast tissue with accessory nipple-areolar complex. The mean operation time was 58 min. All cyclic axillar pain in our cases was resolved after the operation. Postoperative complications developed in 160 patients (16.55%). Among them, seroma after operation was the most common (11.27%). In our study, 95.65% of the patients were satisfied with the cosmetic outcomes. The surgical excision of accessory breasts with liposuction through the minimal incision is a safe and effective method to make women feel comfortable in clinical manifestations and be satisfied with their cosmetic axillar line. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Accessory costs of seed production and the evolution of angiosperms.
Lord, Janice M; Westoby, Mark
2012-01-01
Accessory costs of reproduction frequently equal or exceed direct investment in offspring, and can limit the evolution of small offspring sizes. Early angiosperms had minimum seed sizes, an order of magnitude smaller than their contemporaries. It has been proposed that changes to reproductive features at the base of the angiosperm clade reduced accessory costs thus removing the fitness disadvantage of small seeds. We measured accessory costs of reproduction in 25 extant gymnosperms and angiosperms, to test whether angiosperms can produce small seeds more economically than gymnosperms. Total accessory costs scaled isometrically to seed mass for angiosperms but less than isometrically for gymnosperms, so that smaller seeds were proportionally more expensive for gymnosperms to produce. In particular, costs of abortions and packaging structures were significantly higher in gymnosperms. Also, the relationship between seed:ovule ratio and seed size was negative in angiosperms but positive in gymnosperms. We argue that the carpel was a key evolutionary innovation reducing accessory costs in angiosperms by allowing sporophytic control of pre- and postzygotic mate selection and timing of resource allocation. The resulting reduction in costs of aborting unfertilized ovules or genetically inferior embryos would have lowered total reproductive costs enabling early angiosperms to evolve small seed sizes and short generation times. © 2011 The Author(s). Evolution © 2011 The Society for the Study of Evolution.
[Evaluation of iatrogenic accessory nerve injury in forensic medical practice].
Somogyi, E; Irányi, J
1996-04-14
The authors give a survey of the clinical and medical-legal characteristics of the accessory nerve injury. In the past two decades the conception of the successfulness of the surgical treatment of the accessory nerve injury became prevailing. About the medical-legal aspects of the iatrogenic injury of the nerve reported in connection of the reconstructive surgery chiefly also departments of neurosurgery, orthopedics and traumatology. In the case of the authors a 70 year old patient suffered 10 years ago a iatrogenic accessory nerve injury. The mild trapezius palsy recovered spontaneously practically with cosmetic disadvantage. In connection with the development of extreme dorso-lumbal scoliosis associated with torsion the trapezius atrophy worsened. Physical therapy was partly successful. But the patient became unfit for manual work. Their observations sustain the data of authors who established that in the case of accessory nerve injury not only the surgical but also conservative treatment is usually successful. In opposite to certain data of the literature the authors establish that the iatrogenic injuries of the accessory nerve may lead to significant lifelong disability. The diagnosis is not always made in time with consequent delay in repair. This may be regarded as an unfavorable issue during medical-legal discussions. The authors recommend in interest to prevent nerve injury in the posterior triangle of the neck to perform operation in special department.
21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction... or embryos. Variations of microscopes and accessories used for these purposes would include phase...
Giant accessory breast: a rare occurrence reported, with a review of the literature.
Hiremath, Bharati; Subramaniam, Narayana; Chandrashekhar, Nayan
2015-11-05
Polymastia, or the presence of supranumerary breasts, occurs in 2-6% of the female population, the spectrum of the disorder ranging between a small mole and a fully functional ectopic breast. They are often asymptomatic but require treatment when symptomatic or if they harbour malignancy. We present a case of a 41-year-old woman with an accessory breast in the left inframammary fold, which increased in size over the decade following her first pregnancy, to reach a size almost three times that of her right breast. Preoperative fine-needle aspiration and ultrasound was suggestive of accessory breast tissue, distinct from the left breast. Intraoperatively, a 14×10×8 cm accessory breast was found in the inframammary fold, distinct from the left breast and having an accessory nipple areola complex as well. A simple mastectomy was performed with trimming and rotation of the inframammary flap. The patient was happy with the cosmetic outcome. This article also reviews the literature and covers classification of polymastia, diagnostic complexities and challenges associated with surgery. 2015 BMJ Publishing Group Ltd.
Giant accessory breast: a rare occurrence reported, with a review of the literature
Hiremath, Bharati; Subramaniam, Narayana; Chandrashekhar, Nayan
2015-01-01
Polymastia, or the presence of supranumerary breasts, occurs in 2–6% of the female population, the spectrum of the disorder ranging between a small mole and a fully functional ectopic breast. They are often asymptomatic but require treatment when symptomatic or if they harbour malignancy. We present a case of a 41-year-old woman with an accessory breast in the left inframammary fold, which increased in size over the decade following her first pregnancy, to reach a size almost three times that of her right breast. Preoperative fine-needle aspiration and ultrasound was suggestive of accessory breast tissue, distinct from the left breast. Intraoperatively, a 14×10×8 cm accessory breast was found in the inframammary fold, distinct from the left breast and having an accessory nipple areola complex as well. A simple mastectomy was performed with trimming and rotation of the inframammary flap. The patient was happy with the cosmetic outcome. This article also reviews the literature and covers classification of polymastia, diagnostic complexities and challenges associated with surgery. PMID:26542818
Erb, P; Ramila, G; Sklenar, I; Kennedy, M; Sunshine, G H
1985-05-01
Dendritic cells and macrophages obtained from spleen and peritoneal exudate were tested as accessory cells for the activation of lymphokine production by T cells, for supporting T-B cooperation and for the induction of antigen-specific T helper cells. Dendritic cells as well as macrophages were able to activate T cells for interleukin-2 secretion and functioned as accessory cells in T-B cooperation, but only macrophages induced T helper cells, which cooperate with B cells by a linked recognition interaction, to soluble antigens. Dendritic cell- and antigen-activated T cells also did not help B cells in the presence of Con A supernatants which contained various T cell- and B cell-stimulatory factors. The failure of dendritic cells to differentiate memory into functional T helper cells, but their efficient accessory cell function in T-B cooperation, where functional T helper cells are already present, can be best explained by a differential accessory cell requirement for T helper cell activation dependent on the differentiation stage of the T helper cell.
The benefits of using bluetooth accessories with hearing aids.
Smith, Pauline; Davis, Adrian
2014-10-01
To investigate the benefits in reported outcomes after providing bluetooth accessories for established hearing aid users. Prospective observational study using validated quantitative outcome measures and detailed patient narrative before and two months after patients were provided with bluetooth accessories. Twelve patients with bilateral NHS hearing aids participated. They had a wide range of ages and hearing loss. After two months, 10 patients reported substantial additional benefit and kept the accessories; two returned them for various reasons. Statistically significant changes were seen in two validated outcome measures: the Glasgow Hearing Aid Benefit Profile and the International Outcome Inventory - Hearing Aids, but not in the Speech, Spatial and Qualities of Hearing Scale. Two notable benefits were reported: some described hearing the emotion and mood in a voice for the first time; others were amazed to report an improved ability to hear film or to hold conversations over the telephone. The provision of bluetooth accessories can give additional reported benefit for some patients - we need better knowledge about who benefits, and whether further support/training to individuals would make a difference.
Udink ten Cate, Floris EA; Wiesner, Nathalie; Trieschmann, Uwe; Khalil, Markus; Sreeram, Narayanswami
2010-01-01
A subset of children and adults with Wolff-Parkinson-White (WPW) syndrome develop dilated cardiomyopathy (DCM). Although DCM may occur in symptomatic WPW patients with sustained tachyarrhythmias, emerging evidence suggests that significant left ventricular dysfunction may arise in WPW in the absence of incessant tachyarrhythmias. An invariable electrophysiological feature in this non-tachyarrhythmia type of DCM is the presence of a right-sided septal or paraseptal accessory pathway. It is thought that premature ventricular activation over these accessory pathways induces septal wall motion abnormalities and ventricular dyssynchrony. LV dyssynchrony induces cellular and structural ventricular remodelling, which may have detrimental effects on cardiac performance. This review summarizes recent evidence for development of DCM in asymptomatic patients with WPW, discusses its pathogenesis, clinical presentation, management and treatment. The prognosis of accessory pathway-induced DCM is excellent. LV dysfunction reverses following catheter ablation of the accessory pathway, suggesting an association between DCM and ventricular preexcitation. Accessory pathway-induced DCM should be suspected in all patients presenting with heart failure and overt ventricular preexcitation, in whom no cause for their DCM can be found. PMID:20552060
Wolf, Thomas Gerhard; Paqué, Frank; Zeller, Maximilian; Willershausen, Brita; Briseño-Marroquín, Benjamín
2016-04-01
The aim of this study was to investigate the root canal system morphology of the mandibular first molar by means of micro-computed tomography. The root canal configuration, foramina, and accessory canals frequency of 118 mandibular first molars were investigated by means of micro-computed tomography and 3-dimensional software imaging. A 4-digit system describes the root canal configuration from the coronal to apical thirds and the main foramina number. The most frequent root canal configurations in mesial root were 2-2-2/2 (31.4%), 2-2-1/1 (15.3%), and 2-2-2/3 (11.9%); another 24 different root canal configurations were observed in this root. A 1-1-1/1 (58.5%), 1-1-1/2 (10.2%), and 16 other root canal configurations were observed in the distal root. The mesiobuccal root canal showed 1-4 foramina in 24.6%, and the mesiolingual showed 1-3 foramina in 28.0%. One connecting canal between the mesial root canals was observed in 30.5% and 2 in 3.4%. The distolingual root canal showed 1-4 foramina in 23.7%, whereas a foramen in the distobuccal root canal was rarely detected (3.4%). The mesiobuccal, mesiolingual, and distolingual root canals showed at least 1 accessory canal (14.3, 10.2, and 4.2%, respectively), but the distobuccal had none. The root canal configuration of mandibular first molars varies strongly. According to our expectations, both the mesial and distal roots showed a high number of morphologic diversifications. The root canal system of the mesial root showed more root canal configuration variations, connecting and accessory canals than the distal root. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Gibson, Kathleen; Ferris, Brian
2017-04-01
Purpose Cyanoacrylate closure of the great saphenous vein with the VenaSeal™ Closure System is a relatively new modality. Studies have been limited to moderate-sized great saphenous veins and some have mandated postoperative compression stockings. We report the results of a prospective study of cyanoacrylate closure for the treatment of great saphenous vein, small saphenous veins, and/or accessory saphenous veins up to 20 mm in diameter. Methods Fifty subjects with symptomatic great saphenous vein, small saphenous veins, and/or accessory saphenous veins incompetence were each treated at a single session. Compression stockings were not used post-procedure. Subjects returned to clinic at week 1 and again at one month. Post-procedure evaluations were performed at seven days and one month and included numerical pain rating score, revised venous clinical severity score, the Aberdeen Varicose Vein Questionnaire score, and time to return to work and normal activities. Duplex ultrasound was performed at each visit. Findings Procedural pain was mild (numerical pain rating scale 2.2 ± 1.8). All treated veins (48 great saphenous vein, 14 accessory saphenous veins, and 8 small saphenous veins) had complete closure by duplex ultrasound at seven days and one month. Mean time to return to work and normal activities was 0.2 ± 1.1 and 2.4 ± 4.1 days, respectively. The revised venous clinical severity score was improved to 1.8 ± 1.4 ( p < .001) and Aberdeen Varicose Vein Questionnaire score to 8.9 ± 6.6 ( p < .001) at one month. Phlebitis in the treatment area or side branches occurred in 10 subjects (20%) and completely resolved in all but one subject (2%) by one month; 98% of subjects were "completely" or "somewhat" satisfied, and 2% "unsatisfied" with the procedure at one month, despite the protocol disallowance of concomitant side branch treatment. Conclusions Cyanoacrylate closure is safe and effective for the treatment of one or more incompetent saphenous or accessory saphenous veins. Closure rates were high even in the absence of the use of compression stockings or side branch treatment. Time back to work or normal activities was short and improvements in venous severity scores and QOL were significant, comparing favorably with alternative treatment methods.
21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... accessories is a device used to perform electrosurgical procedures through an endoscope. This generic type of device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode...
Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.
Stino, Amro M; Smith, Benn E
2018-01-01
Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...
21 CFR 884.1720 - Gynecologic laparoscope and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... genital organs. This generic type of device may include: Trocar and cannula, instruments used through an... accessory instruments include: the lens cleaning brush, biopsy brush, clip applier (without clips...
An Accessory Muscle of Pectoral Region: A Case Report
Bannur, B.M.; Mallashetty, Nagaraj; Endigeri, Preetish
2013-01-01
Among the variations of pectoral muscles, this case appears to be unique in the literature. This was a case of an accessory pectoral muscle which was located between pectoralis major and pectoralis minor muscles, which was discovered during a routine anatomy dissection. The accessory muscle originated from 6th and 7th ribs at costo-chondral junction, which travelled supero-laterally and inserted by fusing with fibres of pectoralis minor. This unusual muscle holds importance for surgeons while they perform dissectomies, in avoiding complications. PMID:24179919
Sorensen, Sorena S.; Grossman, Jeffrey N.
1993-01-01
Data from the Gee Point and Catalina mélanges suggest that the accessory minerals titanite, rutile, apatite, zircon and REE-rich epidote play a significant role in the enrichment of trace elements in both mafic and ultramafic rocks during subduction-related fluid-rock interaction. Mobilization of incompatible elements, and deposition of such elements in the accessory minerals of mafic and ultramafic rocks may be fairly common in fluid-rich metamorphic environments in subduction zones.
76 FR 56318 - Parts and Accessories Necessary for Safe Operation; Saddle-Mount Braking Requirements
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-13
... a petition for rulemaking from the Automobile Carriers Conference (ACC) of the American Trucking... antilock braking systems. ACC Automobile Carriers Conference. ATA American Trucking Associations. ATC ATC... Carrier Safety Regulations. NATA National Automobile Transporters Association. NPRM notice of proposed...
NASA Technical Reports Server (NTRS)
Nittler, Larry R.
2003-01-01
This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to support our analytical facilities for extraterrestrial samples. After evaluating several instruments, we purchased a JEOL 6500F thermal field emission SEM with the following analytical accessories: EDAX energy-dispersive x-ray analysis system with fully automated control of instrument and sample stage; EDAX LEXS wavelength-dispersive x-ray spectrometer for high sensitivity light-element analysis; EDAX/TSL electron backscatter diffraction (EBSD) system with software for phase identification and crystal orientation mapping; Robinson backscatter electron detector; and an in situ micro-manipulator (Kleindiek). The total price was $550,000 (with $150,000 of the purchase supported by Carnegie institution matching funds). The microscope was delivered in October 2002, and most of the analytical accessories were installed by January 2003. With the exception of the wavelength spectrometer (which has been undergoing design changes) everything is working well and the SEM is in routine use in our laboratory.
Maricich, Stephen M.; Xia, Anping; Mathes, Erin L.; Wang, Vincent Y.; Oghalai, John S.; Fritzsch, Bernd; Zoghbi, Huda Y.
2009-01-01
Atoh1 is a basic helix-loop-helix transcription factor necessary for the specification of inner ear hair cells and central auditory system neurons derived from the rhombic lip. We used the Cre-loxP system and two Cre-driver lines (Egr2Cre and Hoxb1Cre) to delete Atoh1 from different regions of the cochlear nucleus (CN) and accessory auditory nuclei (AAN). Adult Atoh1-conditional knockout mice (Atoh1CKO) are behaviorally deaf, have diminished auditory brainstem evoked responses and disrupted CN and AAN morphology and connectivity. In addition, Egr2; Atoh1CKO mice lose spiral ganglion neurons in the cochlea and AAN neurons during the first 3 days of life, revealing a novel critical period in the development of these neurons. These new mouse models of predominantly central deafness illuminate the importance of the CN for support of a subset of peripheral and central auditory neurons. PMID:19741118
Wülbeck, Corinna; Grieshaber, Eva; Helfrich-Förster, Charlotte
2008-10-01
The neuropeptide pigment-dispersing factor (PDF) is a key transmitter in the circadian clock of Drosophila melanogaster. Here we studied the rhythmic behavior of neural mutants with modified arborizations of the large PDF neurons. In sine oculis(1) (so(1)) mutants we found a higher density of PDF fibers in the fly's pacemaker center, the accessory medulla. These flies exhibited a significantly longer period (24.6 h) than control flies. When PDF levels were elevated to very high levels in the dorsal brain as true for so(mda) mutants and small optic lobes;so(1) double mutants (sol(1);so( 1)), a short-period component split off the long period in behavioral rhythmicity. The short period became shorter the higher the amount of PDF in this brain region and reached a value of approximately 21 h. The period alterations were clearly dependent on PDF, because so(1);Pdf 01 and so(mda);Pdf 01 double mutants showed a single free-running component with a period similar to Pdf 01 mutants (approximately 22.5 h) and significantly longer than the short period of so(mda) mutants. These observations indicate that PDF feeds back on the clock neurons and changes their period. Obviously, PDF lengthens the period of some clock neurons and shortens that of others.
Kumari, Sonu; Luthra, R A; Chandolia, R K; Kumar, Sandeep; Kumar, Parveen; Devender; Kumar, Ankit; Bishnoi, Nidhi; Bishnoi, Sunil
2016-04-01
The present study was undertaken to study growth pattern of accessory sex glands in prepubertal kids from 2 weeks to 6 months of age using two-dimensional ultrasonography. The study was conducted on six Beetal kids. The scanning of accessory sex glands was done in standing position using rectal probe and measurements were recorded. Data collected were statistically analyzed using one-way ANOVA followed by Duncan multiple range test was performed using the SPSS (16.0) system for windows. With the advancement of age all the dimensions of glands increased. Both the lobes of prostate gland showed an increase in width with advancement of age. Width of prostate above the urethra (W1) showed a significant increase at 2, 10, and 20 weeks of age, whereas non-significant increase from 2 to 8, 10 to 19, and 20 to 24 weeks of age was recorded. Width of prostate below the urethra (W2) showed a significant increase at 20 weeks of age, whereas non-significant increase was recorded during rest of period of growth. Left and right bulbourethral gland showed a similar pattern of growth with the advancement of age. The circumference dimensions increased significantly at 2, 16, 20, and 21 weeks of age for both glands. The increase was non-significant from 4 to 14, 16 to 19, and 20 to 23 weeks of age. The same pattern was observed for left and right seminal vesicular gland. Significant growth in three accessory sex glands in prepubertal kids was not observed at the same age. The trend observed was that the prostate was the first gland to show significant growth at 10 weeks of age followed by a significant increase in seminal vesicles and bulbourethral gland at 14 and 16 weeks of age, respectively.
Factors Required for Activation of Urease as a Virulence Determinant in Cryptococcus neoformans
Singh, Arpita; Panting, Robert J.; Varma, Ashok; Saijo, Tomomi; Waldron, Kevin J.; Jong, Ambrose; Ngamskulrungroj, Popchai; Chang, Yun C.; Rutherford, Julian C.; Kwon-Chung, Kyung J.
2013-01-01
ABSTRACT Urease in Cryptococcus neoformans plays an important role in fungal dissemination to the brain and causing meningoencephalitis. Although urea is not required for synthesis of apourease encoded by URE1, the available nitrogen source affected the expression of URE1 as well as the level of the enzyme activity. Activation of the apoenzyme requires three accessory proteins, Ure4, Ure6, and Ure7, which are homologs of the bacterial urease accessory proteins UreD, UreF, and UreG, respectively. A yeast two-hybrid assay showed positive interaction of Ure1 with the three accessory proteins encoded by URE4, URE6, and URE7. Metalloproteomic analysis of cryptococcal lysates using inductively coupled plasma mass spectrometry (ICP-MS) and a biochemical assay of urease activity showed that, as in many other organisms, urease is a metallocentric enzyme that requires nickel transported by Nic1 for its catalytic activity. The Ure7 accessory protein (bacterial UreG homolog) binds nickel likely via its conserved histidine-rich domain and appears to be responsible for the incorporation of Ni2+ into the apourease. Although the cryptococcal genome lacks the bacterial UreE homolog, Ure7 appears to combine the functions of bacterial UreE and UreG, thus making this pathogen more similar to that seen with the plant system. Brain invasion by the ure1, ure7, and nic1 mutant strains that lack urease activity was significantly less effective in a mouse model. This indicated that an activated urease and not the Ure1 protein was responsible for enhancement of brain invasion and that the factors required for urease activation in C. neoformans resemble those of plants more than those of bacteria. PMID:23653445
Functional characterisation of a TLR accessory protein, UNC93B1, in Atlantic salmon (Salmo salar).
Lee, P T; Zou, J; Holland, J W; Martin, S A M; Scott, C J W; Kanellos, T; Secombes, C J
2015-05-01
Toll-like receptors (TLRs) are indispensable components of the innate immune system, which recognise conserved pathogen associated molecular patterns (PAMPs) and induce a series of defensive immune responses to protect the host. Biosynthesis, localisation and activation of TLRs are dependent on TLR accessory proteins. In this study, we identified the accessory protein, UNC93B1, from Atlantic salmon (Salmo salar) whole-genome shotgun (WGS) contigs aided by the conserved gene synteny of genes flanking UNC93B1 in fish, birds and mammals. Phylogenetic analysis showed that salmon UNC93B1 grouped with other vertebrate UNC93B1 molecules, and had highest amino acid identity and similarity to zebrafish UNC93B1. The salmon UNC93B1 gene organisation was also similar in structure to mammalian UNC93B1. Our gene expression studies revealed that salmon UNC93B1 was more highly expressed in spleen, liver and gill tissues but was expressed at a lower level in head kidney tissue in post-smolts relative to parr. Moreover, salmon UNC93B1 mRNA transcripts were up-regulated in vivo in spleen tissue from polyI:C treated salmon and in vitro in polyI:C or IFNγ stimulated Salmon Head Kidney-1 (SHK-1) cells. Initial studies into the functional role of salmon UNC93B1 in fish TLR signalling found that both wild type salmon UNC93B1 and a molecule with a site-directed mutation (H424R) co-immunoprecipitated with salmon TLR19, TLR20a and TLR20d. Overall, these data illustrate the potential importance of UNC93B1 as an accessory protein in fish TLR signalling. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dallai, Romano; Gottardo, Marco; Mercati, David; Machida, Ryuichiro; Mashimo, Yuta; Matsumura, Yoko; Rafael, José Albertino; Beutel, Rolf Georg
2014-07-01
The male and female reproductive apparatus of Zorotypus magnicaudelli (Malaysia), Zorotypus huxleyi (Ecuador) and Zorotypus weidneri (Brazil) were examined and documented in detail. The genital apparatus and sperm of the three species show only minor differences. The testes are larger in Z. magnicaudelli. Z. huxleyi lacks the helical appendage in the accessory glands. A long cuticular flagellum is present in Z. magnicaudelli and in the previously studied Zorotypus caudelli like in several other species, whereas it is absent in Z. weidneri, Z. huxleyi, Zorotypus hubbardi, Zorotypus impolitus and Zorotypus guineensis. Characteristic features of the very similar sperm are the presence of: a) two dense arches above the axoneme; b) a 9 + 9+2 axoneme with detached subtubules A and B of doublets 1 and 6; c) the axonemal end degenerating with enlarging accessory tubules; d) accessory tubules with 17 protofilaments; e) three accessory bodies beneath the axoneme; and f) two mitochondrial derivatives of equal shape. The first characteristic (a) is unknown outside of Zoraptera and possibly autapomorphic. The sperm structure differs distinctly in Z. impolitus and Z. hubbardi, which produce giant sperm and possess a huge spermatheca. The presence of the same sperm type in species either provided with a sclerotized coiled flagellum in males or lacking this structure indicates that a different organization of the genital apparatus does not necessarily affect the sperm structure. The flagellum and its pouch has probably evolved within Zoraptera, but it cannot be excluded that it is a groundplan feature and was reduced several times. The fossil evidence and our findings suggest that distinct modifications in the genital apparatus occurred before the fragmentation of the Gondwanan landmass in the middle Cretaceous. Copyright © 2014 Elsevier Ltd. All rights reserved.
21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...
21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...
21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...
21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...
Joint Service Chemical and Biological Defense Program. FY00-02 Overview
2001-09-01
Development. Contractors: 12 BI DS Biological Integrated Detection System (BIDS) Lead Service Bio Road HERCULES, CA Bruker Analytical Systems BILLERICA, MA...Dynamics Land Systems Division DETROIT, MI Henschel Wehrtechnik GERMANY Bruker -Franzen GERMANY Block II – TBD Milestones Block I MS III (2QFY94) Block...ground. Accessories include hoses and hose reels, two trigger-controlled spray wands , and two electrical-powered scrub brush assemblies. The M22
ICPSU Install at Mobile Launcher
2018-03-14
A colorful sunrise serves as the backdrop for the mobile launcher (ML) at NASA's Kennedy Space Center in Florida. Several launch umbilicals have been installed on the ML tower. Exploration Ground Systems is overseeing installation of umbilicals and launch accessories on the ML to prepare for the first integrated test flight of the Orion spacecraft on the agency's Space Launch System rocket on Exploration Mission-1.
Held, Martina; Berz, Annuska; Hensgen, Ronja; Muenz, Thomas S; Scholl, Christina; Rössler, Wolfgang; Homberg, Uwe; Pfeiffer, Keram
2016-01-01
While the ability of honeybees to navigate relying on sky-compass information has been investigated in a large number of behavioral studies, the underlying neuronal system has so far received less attention. The sky-compass pathway has recently been described from its input region, the dorsal rim area (DRA) of the compound eye, to the anterior optic tubercle (AOTU). The aim of this study is to reveal the connection from the AOTU to the central complex (CX). For this purpose, we investigated the anatomy of large microglomerular synaptic complexes in the medial and lateral bulbs (MBUs/LBUs) of the lateral complex (LX). The synaptic complexes are formed by tubercle-lateral accessory lobe neuron 1 (TuLAL1) neurons of the AOTU and GABAergic tangential neurons of the central body's (CB) lower division (TL neurons). Both TuLAL1 and TL neurons strongly resemble neurons forming these complexes in other insect species. We further investigated the ultrastructure of these synaptic complexes using transmission electron microscopy. We found that single large presynaptic terminals of TuLAL1 neurons enclose many small profiles (SPs) of TL neurons. The synaptic connections between these neurons are established by two types of synapses: divergent dyads and divergent tetrads. Our data support the assumption that these complexes are a highly conserved feature in the insect brain and play an important role in reliable signal transmission within the sky-compass pathway.
INTERIOR VIEW OF BATHROOM 2. SHOWING ORIGINAL TILE. CERAMIC ACCESSORIES, ...
INTERIOR VIEW OF BATHROOM 2. SHOWING ORIGINAL TILE. CERAMIC ACCESSORIES, AND MARBLE THRESHOLD. VIEW FACING EAST. - Hickam Field, Officers' Housing Type G, 205 Seventh Street, Honolulu, Honolulu County, HI
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
21 CFR 872.6010 - Abrasive device and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... crowns. The device is attached to a shank that is held by a handpiece. The device includes the abrasive...
30 CFR 18.10 - Notice of approval or disapproval.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES General... assembly of an electrical machine or accessory, MSHA will issue to the applicant either a written notice of...
Electrophysiologic analysis of injury to cranial nerve XI during neck dissection.
Lanisnik, Bostjan; Zargi, Miha; Rodi, Zoran
2016-04-01
Despite preservation of the accessory nerve, a considerable number of patients report partial nerve damage after modified radical neck dissection (MRND) and selective neck dissection. Accessory nerve branches for the trapezius muscle were stimulated during neck dissection, and the M wave amplitude was measured during distinct surgical phases. The accessory nerve was mapped in 20 patients. The M wave recordings indicated that major nerve damage occurred during dissection at levels IIa and IIb in the most proximal segment of the nerve. The M waves evoked from this nerve segment decreased significantly during surgery (analysis of variance; p = .001). The most significant intraoperative injury to the accessory nerve during neck dissection occurs at anatomic nerve levels IIa and IIb. © 2015 Wiley Periodicals, Inc. Head Neck 38: E372-E376, 2016. © 2015 Wiley Periodicals, Inc.
Fanciulli, Pietro Paolo; Mercati, David; Machida, Ryuichiro; Dallai, Romano
2015-06-01
The sperm structure of the jumping bristletail Machilontus sp has been described. The species shares several sperm characteristics with other genera of the same order Archaeognatha. During late spermiogenesis the spermatid bends at half of its length with the two limbs closely apposed within the same plasma membrane. The sperm has a helicoidal bi-layered acrosome with a filamentous perforatorium and a long nucleus. The elongated flagellum consists of an axoneme with 9 accessory microtubules external to the 9+2, two rows of conventional mitochondria and two accessory bodies. The accessory bodies are located lateral to the axoneme and are probably responsible for the shifting of the accessory tubules in two opposite groups of 5 and 4 tubules, respectively. These sperm characteristics represent common traits of all Archaeognatha. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tissue-Specific Transcriptomics in the Field Cricket Teleogryllus oceanicus
Bailey, Nathan W.; Veltsos, Paris; Tan, Yew-Foon; Millar, A. Harvey; Ritchie, Michael G.; Simmons, Leigh W.
2013-01-01
Field crickets (family Gryllidae) frequently are used in studies of behavioral genetics, sexual selection, and sexual conflict, but there have been no studies of transcriptomic differences among different tissue types. We evaluated transcriptome variation among testis, accessory gland, and the remaining whole-body preparations from males of the field cricket, Teleogryllus oceanicus. Non-normalized cDNA libraries from each tissue were sequenced on the Roche 454 platform, and a master assembly was constructed using testis, accessory gland, and whole-body preparations. A total of 940,200 reads were assembled into 41,962 contigs, to which 36,856 singletons (reads not assembled into a contig) were added to provide a total of 78,818 sequences used in annotation analysis. A total of 59,072 sequences (75%) were unique to one of the three tissues. Testis tissue had the greatest proportion of tissue-specific sequences (62.6%), followed by general body (56.43%) and accessory gland tissue (44.16%). We tested the hypothesis that tissues expressing gene products expected to evolve rapidly as a result of sexual selection—testis and accessory gland—would yield a smaller proportion of BLASTx matches to homologous genes in the model organism Drosophila melanogaster compared with whole-body tissue. Uniquely expressed sequences in both testis and accessory gland showed a significantly lower rate of matching to annotated D. melanogaster genes compared with those from general body tissue. These results correspond with empirical evidence that genes expressed in testis and accessory gland tissue are rapidly evolving targets of selection. PMID:23390599