Science.gov

Sample records for accident dosimeter intercomparison

  1. PNNL Results from 2009 Silene Criticality Accident Dosimeter Intercomparison Exercise

    SciTech Connect

    Hill, Robin L.; Conrady, Matthew M.

    2010-06-30

    This document reports the results of testing of the Hanford Personnel Nuclear Accident Dosimeter (PNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on October 13, 14, and 15, 2009.

  2. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    SciTech Connect

    Hill, Robin L.; Conrady, Matthew M.

    2011-10-28

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participating Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.

  3. Characterization of a nuclear accident dosimeter

    SciTech Connect

    Burrows, R.A.

    1995-12-01

    The 23rd nuclear accident dosimetry intercomparison was held during the week of June 12--16, 1995 at Los Alamos National Laboratory. This report presents the results of this event, referred to as NAD 23, as related to the performance of Sandia National Laboratories (SNL) personal nuclear accident dosimeter (PNAD). Two separate critical assemblies, SHEBA and Godiva, were used to generate seven separate neutron spectra for use in dose comparisons. SNL`s PNAD measured absorbed doses that were within +16 to +26% of the reference doses. In addition, a preliminary investigation was undertaken to determine the feasibility of using the data obtained from an irradiated PNAD to correct for body orientation. This portion of the experiment was performed with a TRIGA reactor at the Nuclear Science Center at Texas A and M University.

  4. Third intercomparison of DOE High-Energy Neutron Personnel Dosimeters

    SciTech Connect

    McDonald, J.C.; Akabani, G.; Loesch, R.M.

    1995-12-31

    An intercomparison of the dose equivalent response of personal dosimeters in use at U.S. Department of Energy (DOE) accelerator facilities was performed at the European Laboratory for Particle Physics (CERN). This is the third such intercomparison sponsored by the DOE. The two previous intercomparisons were performed in a U.S. laboratory using a source of high-energy neutrons. This intercomparison was performed at two positions relative to the main beam line at CERN. The neutron-energy spectra present at these two locations were measured by CERN personnel using Bonner sphere spectrometer systems. In addition, the dose equivalents at these two positions were also measured by CERN personnel using a tissue equivalent proportional counter system. The DOE dosimeters were mailed to CERN and returned after irradiation for readout. The results of this intercomparison are relatively consistent with the two previous intercomparisons performed in the U.S. The relative dose equivalent responses of neutron dosimeter types, such as albedo, nuclear emulsion and track-etch plastics, were found to have variations relative to the mean value responses of up to a factor of three.

  5. Angular dependence of a simple accident dosimeter

    SciTech Connect

    Devine, R. T.; Romero, L. L.; Olsher, R. H.

    2004-01-01

    A simple dosimeter made of a sulfur tablet, bare and cadmium covered indium foils and a cadmium covered copper foil has been modeled using MCNP5. Studies of the model without phantom or other confounding factors have shown that the cross sections and fluence-to-dose factors generated by the Monte Carlo method agree with those generated by analytic expressions for the high energy component. The threshold cross sections for the detectors on a phantom were calculated. The resulting doses assigned agree well with exposures made to three critical assemblies. In this study the angular dependence on a phantom is studied and compared with measurements taken on the GODIVA reactor. The dosimeter positions on the phantom are facing the source, on the back and the side. In previous papers the modeling of a simple dosimeter made of a sulfur tablet, bare and cadmium covered indium foils and a cadmium covered copper foil has been modeled using MCNP5. The conclusion made was that most of the neutron dose from criticality assemblies results from the high energy neutron fluences determined by the sulfur and indium detectors. The results using doses measured from the GODIVA, SHEBA, and bare and lead shielded SILENE reactors confirmed this. The angular dependence of an accident dosemeter is of interest in evaluating the exposure of personnel. To investigate this effect accident dosemeters were placed on a phantom and exposed to the GODIVA reactor at phantom orientations of 0{sup o}, 45{sup o}, 90{sup o}, 135{sup o}, and 180{sup o} to the assembly center line.

  6. Evaluation of LLNL's Nuclear Accident Dosimeters at the CALIBAN Reactor September 2010

    SciTech Connect

    Hickman, D P; Wysong, A R; Heinrichs, D P; Wong, C T; Merritt, M J; Topper, J D; Gressmann, F A; Madden, D J

    2011-06-21

    The Lawrence Livermore National Laboratory uses neutron activation elements in a Panasonic TLD holder as a personnel nuclear accident dosimeter (PNAD). The LLNL PNAD has periodically been tested using a Cf-252 neutron source, however until 2009, it was more than 25 years since the PNAD has been tested against a source of neutrons that arise from a reactor generated neutron spectrum that simulates a criticality. In October 2009, LLNL participated in an intercomparison of nuclear accident dosimeters at the CEA Valduc Silene reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison of nuclear accident dosimeters at CEA Valduc. The reactor generated neutron irradiations for the 2010 exercise were performed at the Caliban reactor. The Caliban results are described in this report. The procedure for measuring the nuclear accident dosimeters in the event of an accident has a solid foundation based on many experimental results and comparisons. The entire process, from receiving the activated NADs to collecting and storing them after counting was executed successfully in a field based operation. Under normal conditions at LLNL, detectors are ready and available 24/7 to perform the necessary measurement of nuclear accident components. Likewise LLNL maintains processing laboratories that are separated from the areas where measurements occur, but contained within the same facility for easy movement from processing area to measurement area. In the event of a loss of LLNL permanent facilities, the Caliban and previous Silene exercises have demonstrated that LLNL can establish field operations that will very good nuclear accident dosimetry results. There are still several aspects of LLNL's nuclear accident dosimetry program that have not been tested or confirmed. For instance, LLNL's method for using of biological samples (blood and hair) has not been verified since the method was first developed in the 1980's. Because LLNL and the other DOE

  7. Twenty-second ORNL intercomparison of criticality accident dosimetry systems, August 12-16, 1985

    SciTech Connect

    Swaja, R.E.; Oyan, R.; Sims, C.S.

    1986-05-01

    The twenty-second in a series of criticality accident dosimetry intercomparison studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 12-16, 1985. The Health Physics Research Reactor operated in the pulse mode over Storage Pit No. 1 was used to simulate three criticality accidents with different radiation fields. Participants from nine organizations measured neutron doses between 0.36 and 3.78 Gy and gamma doses between 0.22 and 0.80 Gy at area monitoring stations and on phantoms. Approximately 68% of all neutron dose estimates based on foil activation, thermoluminescent, hair activation, and blood sodium activation methods were within +-25% of reference values. About 44% of all gamma results measured using thermoluminescent dosimeters (TLD-700 or CaSO/sub 4/ phosphors) were within 20% of reference doses. The generally poor measurement accuracy exhibited in this study indicates a need for continuing ORNL accident dosimetry intercomparison and training programs.

  8. Performance of the CEDS Accident Dosimetry System at the 1995 Los Alamos National Laboratory Nuclear Accident Dosimetry Intercomparison

    SciTech Connect

    McMahan, K.L.; Schwanke, L.J.

    1996-12-01

    In July 1995, LANL hosted an accident dosimetry intercomparison. When all reactors on the Oak Ridge Reservation were idled in 1988, the Health Physics Research Reactor (HPRR), which had been used for 22 previous intercomparisons dating from 1965, was shut down for an indefinite period. The LANL group began characterization of two critical assemblies for dosimetry purposes. As a result, NAD-23 was conceived and 10 DOE facilities accepted invitations to participate in the intercomparison. This report is a summary of the performance of one of the participants, the Centralized External Dosimetry System (CEDS). The CEDS is a cooperative personnel dosimetry arrangement between three DOE sites in Oak Ridge, Tennessee. Many successes and failures are reported herein. Generally, the TL dosimeters performed poorly and always over-reported the delivered dose. The TLD processing procedures contain efforts that would lead to large biases in the reported absorbed dose, and omit several key steps in the TLD reading process. The supralinear behavior of lithium fluoride (LiF) has not been characterized for this particular dosimeter and application (i.e., in high-dose mixed neutron/gamma fields). The use of TLD materials may also be precluded given the limitations of the LiF material itself, the TLD reading system, and the upper dose level to which accident dosimetry systems are required to perform as set forth in DOE regulations. The indium foil results confirm the expected inability of that material to predict the magnitude of the wearer`s dose reliably, although it is quite suitable as a quick-sort material. Biological sample (hair) results were above the minimum detectable activity (MDA) for only one of the tests. Several questions as to the best methods for sample handling and processing remain.

  9. Nineteenth nuclear accident dosimetry intercomparison study, August 9-13, 1982

    SciTech Connect

    Greene, R.T.; Sims, C.C.; Swaja, R.E.

    1983-11-01

    The Nineteenth Nuclear Accident Dosimetry Intercomparison Study was held August 9 to 13, 1982, at the Oak Ridge National Laboratory using the Health Physics Research Reactor operated in the pulse mode to simulate nuclear criticality accidents. Participants from eight organizations measured neutron and gamma doses at air stations and on phantoms for three different shielding conditions. Measured results were compared to nuclear industry guidelines for criticality accident dosimeters which suggest accuracies of +-25% for neutron dose and +-20% for gamma dose. Seventy-two percent of the neutron dose measurements using foil activation, sodium activation, hair sulfur activation, and thermoluminescent methods met the guidelines while less than 40% of the gamma dose measurements were within +-20% of reference values. The softest neutron energy spectrum (also lowest neutron/gamma dose ratio) provided the most difficulty in measuring neutron and gamma doses. Results of this study indicate the need for continued intercomparison and testing of nuclear accident dosimetry systems and for training of evaluating personnel. 14 references, 7 figures, 16 tables.

  10. Sugar as an emergency populace dosimeter for radiation accidents

    SciTech Connect

    Nakajima, T.

    1988-12-01

    Ordinary sugar can be used as an emergency dosimeter for any person exposed to a nuclear or radiation accident. The number of free radicals in sugar created by radiation does not decrease at room temperature for two months after irradiation and is not changed by thermal treatment for about 18 h at even 55 degrees C. A 600 mg granulated sugar sample can detect about 0.05 Gy (5 rad) as the minimum detectable absorbed dose using electron spin resonance equipment. If sugar is present at the time of a radiation or nuclear accident, the absorbed dose can be evaluated from the sugar and will be useful for both the medical treatment and health effects of the exposed persons.

  11. Results from 2010 Caliban Criticality Dosimetry Intercomparison

    SciTech Connect

    Veinot, K. G.

    2011-10-12

    The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

  12. Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

    PubMed

    Romanyukha, Alexander; King, David L; Kennemur, Lisa K

    2012-05-01

    After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations.

  13. INTERCOMPARISON OF RESULTS FOR A PWR ROD EJECTION ACCIDENT

    SciTech Connect

    DIAMOND,D.J.; ARONSON,A.; JO,J.; AVVAKUMOV,A.; MALOFEEV,V.; SIDOROV,V.; FERRARESI,P.; GOUIN,C.; ANIEL,S.; ROYER,M.E.

    1999-10-01

    This study is part of an overall program to understand the uncertainty in best-estimate calculations of the local fuel enthalpy during the rod ejection accident. Local fuel enthalpy is used as the acceptance criterion for this design-basis event and can also be used to estimate fuel damage for the purpose of determining radiological consequences. The study used results from neutron kinetics models in PARCS, BARS, and CRONOS2, codes developed in the US, the Russian Federation, and France, respectively. Since BARS uses a heterogeneous representation of the fuel assembly as opposed to the homogeneous representations in PARCS and CRONOS, the effect of the intercomparison was primarily to compare different intra-assembly models. Quantitative comparisons for core power, reactivity, assembly fuel enthalpy and pin power were carried out. In general the agreement between methods was very good providing additional confidence in the codes and providing a starting point for a quantitative assessment of the uncertainty in calculated fuel enthalpy using best-estimate methods.

  14. Determination of possible damage/degradation of the Sandia National Laboratories Personal Nuclear Accident Dosimeter (PNAD).

    SciTech Connect

    Potter, Charles Augustus; Ward, Dann C.

    2008-05-01

    This report describes the results of an inspection performed on the existing stock of SNL Personal Nuclear Accident Dosimeters (PNADs). The current stock is approximately 20 years old, and has not been examined since their initial acceptance. A small random sample of PNADs were opened (a destructive process) and the contents visually examined. Sample contents were not degraded and indicate that the existing stock of SNL PNADs is acceptable for continued use.

  15. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    SciTech Connect

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed.

  16. Design of an advanced TLD-based fixed nuclear accident dosimeter

    SciTech Connect

    Casson, W.H.; Mei, G.T.

    1993-08-01

    A new system has been designed for use as a fixed nuclear accident dosimeter based upon the thermoluminescent dosimeter (TLD) system used for personnel dosimetry at US Department of Energy facilities managed by Martin Marietta Energy Systems, Inc. The system is made up of a small phantom consisting of two main parts measuring 20 x 20 x 5 cm and made from polymethylmethacrylate. A neutron-sensitive TLD card is placed in the center between the two pieces. Also, TLD cards in standard holders are mounted on the front and back of the phantom. A derivation is made of a linear combination of the responses from the TLD elements which results in calculation of the neutron fluence, absorbed dose, and dose equivalent. By using the right linear combinations, a crude spectrum can be estimated, which allows further calculation of the average fluence-to-dose-equivalent conversion factor. The response of the system was tested and found to be applicable for the evaluation of typical nuclear accident spectra, although considerable improvement can be made by the addition of a sulfur pellet. The system was also tested for angular dependence. In order to move the development of this system from the proof-of-principle to full application, the calculation of the TLD resonse curves must be improved, additional measurements must be made, and the system must be tested in a simulated accident neutron field. The advantages of the new fixed dosimeter system are its simplicity, easy maintenance, and lower operational cost. The system uses standard TLD cards that are already in place throughout Energy Systems facilities. The TLD process personnel are famliiar with evaluating doses from TLDs and can provide information necessary to ensure timely and accurate assessment of exposures that may result from riticality accidents. Most of the quality control requirements are part of the existing personnel dosimetry system.

  17. Twenty-first nuclear accident dosimetry intercomparison study, August 6-10, 1984

    SciTech Connect

    Swaja, R.E.; Ragan, G.E.; Sims, C.S.

    1985-05-01

    The twenty-first in a series of nuclear accident dosimetry (NAD) intercomparison (NAD) studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 6-10, 1984. The Health Physics Research Reactor operated in the pulse mode was used to simulate three criticality accidents with different radiation fields. Participants from five organizations measured neutron doses between 0.53 and 4.36 Gy and gamma doses between 0.19 and 1.01 Gy at area monitoring stations and on phantoms. About 75% of all neutron dose estimates based on foil activation, hair activation, simulated blood sodium activation, and thermoluminescent methods were within +-25% of reference values. Approximately 86% of all gamma results measured using thermoluminescent (TLD-700 or CaSO/sub 4/) systems were within +-20% of reference doses which represents a significant improvement over previous studies. Improvements observed in the ability of intercomparison participants to estimate neutron and gamma doses under criticality accident conditions can be partly attributed to experience in previous NAD studies which have provided practical tests of dosimetry systems, enabled participants to improve evaluation methods, and standardized dose reporting conventions. 16 refs., 15 tabs.

  18. Evaluation of the response to xenon-133 radiations by thermoluminescent dosimeters used during the accident at Three Mile Island.

    PubMed

    Riley, R J; Zanzonico, P B; Masterson, M E; St Germain, J M; Laughlin, J S

    1982-03-01

    An evaluation is presented of the accuracy and sensitivity of three types of TLD's used during the accident at the Three Mile Island Nuclear Station. This evaluation indicated that, due to the method of calibration, all the dosimeters over-responded to 133Xe radiations. The response ranged from slightly above unity to almost two. Exposures of the TLD's were of two types, namely, the characteristic X-rays either were or were not filtered from the beam. The angular sensitivity of the dosimeters is also reported. PMID:7068394

  19. 1987 Neutron and gamma personnel dosimeter intercomparison study using a D/sub 2/O-moderated /sup 252/Cf source

    SciTech Connect

    Swaja, R.E.; West, L.E.; Sims, C.S.; Welty, T.J.

    1989-05-01

    The thirteenth Personnel Dosimetry Intercomparison Study (i.e., PDIS 13) was conducted during April 1987 as a joint effort by Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research Group and the Southwest Radiation Calibration Center at the University of Arkansas. A total of 48 organizations (34 from the US and 14 from abroad) participated in PDIS 13. Participants submitted a total of 1,113 neutron and gamma dosimeters for this mixed field study. The dosimeters were transferred by mail and were handled by experimental personnel at ORNL and the University of Arkansas. The type of neutron dosimeter and the percentage of participants submitting that type are as follows: TLD-albedo (49%), direct interaction TLD (31%), CR-39 (17%), film (3%). The type of gamma dosimeter and the percentage of participants submitting that type are as follows: Li/sub 2/B/sub 4/O/sub 7/, alone or in combination with CaSO/sub 4/, (69%), /sup 7/LiF (28%), natural LiF (3%). Radiation exposures in PDIS 13 were limited to 0.5 and 1.5 mSv from /sup 252/Cf moderated by 15-cm of D/sub 2/O. Traditional exposures using the Health Physics Research Reactor (HPRR) were not possible due to the fact that all reactors at ORNL, including the HPRR, were shutdown by order of the Department of Energy at the time the intercomparison was performed. Planned exposures using a /sup 238/PuBe source were negated by a faulty timing mechanism. Based on accuracy and precision, direct interaction TLD dosimeters exhibited the best performance in PDIS 13 neutron measurements. They were followed, in order of best performance, by CR-39, TLD albedo, and film. The Li/sub 2/B/sub 4/O/sub 7/ type TLD dosimeters exhibited the best performance in PDIS 13 gamma measurements. They were followed by natural LiF, /sup 7/LiF, and film. 12 refs., 1 fig., 5 tabs.

  20. Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.

    PubMed

    Médioni, R; Asselineau, B; Verrey, B; Trompier, F; Itié, C; Texier, C; Muller, H; Pelcot, G; Clairand, I; Jacquet, X; Pochat, J L

    2004-01-01

    In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue.

  1. Intercomparison of environmental gamma doses measured with A NaI (Tl) survey meter and thermoluminescent dosimeters (TLDs) in the Poonch division of Azad Kashmir, Pakistan.

    PubMed

    Rafique, Muhammad; Kearfott, Kimberlee J; Ahmad, Khalil; Akhter, Jabeen; Khan, Abdul Razzaq; Saeed, Raja Azhar; Rahman, Saeed Ur; Matiullah; Rajput, Muhammad Usman

    2014-12-01

    This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a NaI (Tl) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. During three distinct two month time periods within the six month study period, all the installed dosimeters were exposed to outdoor environmental gamma radiations, retrieved and read out at Radiation Dosimetry Laboratory, Health Physics Division, PINSTECH laboratory, Islamabad. The ambient outdoor gamma dose rate measurements were also taken with NaI (Tl) based portable radiometric instrument at 1 m above the ground. To estimate the annual gamma doses, NaI (Tl) based survey data were used for one complete year following the deployment of the dosimeters. The mean annual gamma dose rates measured by TLDs and survey meter were found as 1.47±0.10 and 0.862±0.003 mGy/y respectively. Taking into account a 29% outdoor occupancy factor, the annual average effective dose rate for individuals was estimated as 0.298±0.04 and 0.175±0.03 mSv/y by TLDs and survey meter, respectively. For outdoor exposure, the ELCR was calculated from the TLD and survey meter measurements. The environmental outdoor average annual effective dose obtained in present study are less than the estimated world average terrestrial and cosmic gamma ray dose rate of 0.9 mSv/y reported in UNSCEAR 2000. The possible origins of gamma doses in the area and incompatibilities of results obtained from the two different measurement techniques are also discussed.

  2. Intercomparison of environmental gamma doses measured with A NaI (Tl) survey meter and thermoluminescent dosimeters (TLDs) in the Poonch division of Azad Kashmir, Pakistan.

    PubMed

    Rafique, Muhammad; Kearfott, Kimberlee J; Ahmad, Khalil; Akhter, Jabeen; Khan, Abdul Razzaq; Saeed, Raja Azhar; Rahman, Saeed Ur; Matiullah; Rajput, Muhammad Usman

    2014-12-01

    This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a NaI (Tl) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. During three distinct two month time periods within the six month study period, all the installed dosimeters were exposed to outdoor environmental gamma radiations, retrieved and read out at Radiation Dosimetry Laboratory, Health Physics Division, PINSTECH laboratory, Islamabad. The ambient outdoor gamma dose rate measurements were also taken with NaI (Tl) based portable radiometric instrument at 1 m above the ground. To estimate the annual gamma doses, NaI (Tl) based survey data were used for one complete year following the deployment of the dosimeters. The mean annual gamma dose rates measured by TLDs and survey meter were found as 1.47±0.10 and 0.862±0.003 mGy/y respectively. Taking into account a 29% outdoor occupancy factor, the annual average effective dose rate for individuals was estimated as 0.298±0.04 and 0.175±0.03 mSv/y by TLDs and survey meter, respectively. For outdoor exposure, the ELCR was calculated from the TLD and survey meter measurements. The environmental outdoor average annual effective dose obtained in present study are less than the estimated world average terrestrial and cosmic gamma ray dose rate of 0.9 mSv/y reported in UNSCEAR 2000. The possible origins of gamma doses in the area and incompatibilities of results obtained from the two different measurement techniques are also discussed. PMID:25484014

  3. The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.

    PubMed

    Gualdrini, G; Bedogni, R; Fantuzzi, E; Mariotti, F

    2004-01-01

    The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry Systems' (Silène reactor, IRSN-CEA-Valduc June 2002). The evaluation of the neutron spectra and the neutron dosimetric quantities relies on activation detectors and on unfolding algorithms. Thermoluminescent detectors are employed for the gamma dose measurement. The work is aimed at accurately characterising the measurement system and, at the same time, testing the algorithms. Useful spectral information were included, based on Monte Carlo simulations, to take into account the potential accident scenarios of practical interest. All along this exercise intercomparison a particular attention was devoted to the 'traceability' of all the experimental and computational parameters and therefore, aimed at an easy treatment by the user.

  4. Personal nuclear accident dosimetry at Sandia National Laboratories

    SciTech Connect

    Ward, D.C.; Mohagheghi, A.H.; Burrows, R.

    1996-09-01

    DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.

  5. The second EURADOS intercomparison of national network systems used to provide early warning of a nuclear accident.

    PubMed

    Sáez-Vergara, J C; Thompson, I M G; Gurriarán, R; Dombrowski, H; Funck, E; Neumaier, S

    2007-01-01

    In 1999 and 2002, the EURADOS Working Group on Environmental Monitoring organised two European intercomparison exercises of national network systems used to provide early warning in case of a nuclear accident. In total, 12 European countries, represented by more than 40 scientists, participated in these two intercomparisons with more than 35 different dose rate detectors. In addition, an in situ gamma spectrometry intercomparison was performed by a group of European scientists during the 2002 exercise. Results of these spectrometry measurements will be reported elsewhere. This report summarises the results of the second intercomparison, performed in 2002, at the environmental dosimetry facilities of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The unique combination of the ultra-low background Underground Laboratory (UDO) and two free-field sites (a floating platform on a lake showing an almost pure cosmic radiation field and a free-field gamma ray irradiation facility) provide the particular opportunity to precisely quantify the inherent background of the detectors and to calibrate them almost free of any background and traceable to PTB's primary standards. In addition, the intercomparison comprised investigations on the energy and dose rate dependence of the detectors' response to gamma radiation as well as on the response to cosmic radiation. Finally, the sensitivity of the detector systems to small dose rate variations, similar to that caused by a passing overhead radioactive plume, was studied under realistic free-field conditions. Following the Council Directive 96/29/EURATOM, the participants of the 2002 intercomparison were asked to report their results in terms of the operational quantity ambient dose equivalent, H(*)(10). Although the verification of the individual calibrations showed smaller discrepancies than those in the 1999 intercomparison, in a few cases, these discrepancies would be still unacceptably high in the case of a real

  6. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario.

    PubMed

    Vives I Batlle, J; Beresford, N A; Beaugelin-Seiller, K; Bezhenar, R; Brown, J; Cheng, J-J; Ćujić, M; Dragović, S; Duffa, C; Fiévet, B; Hosseini, A; Jung, K T; Kamboj, S; Keum, D-K; Kryshev, A; LePoire, D; Maderich, V; Min, B-I; Periáñez, R; Sazykina, T; Suh, K-S; Yu, C; Wang, C; Heling, R

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of (90)Sr, (131)I and (137)Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.

  7. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario.

    PubMed

    Vives I Batlle, J; Beresford, N A; Beaugelin-Seiller, K; Bezhenar, R; Brown, J; Cheng, J-J; Ćujić, M; Dragović, S; Duffa, C; Fiévet, B; Hosseini, A; Jung, K T; Kamboj, S; Keum, D-K; Kryshev, A; LePoire, D; Maderich, V; Min, B-I; Periáñez, R; Sazykina, T; Suh, K-S; Yu, C; Wang, C; Heling, R

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of (90)Sr, (131)I and (137)Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters. PMID:26717350

  8. EPR study of free radicals in cotton fiber for its potential use as a fortuitous dosimeter in radiological accidents

    NASA Astrophysics Data System (ADS)

    Sudprasert, W.; Insuan, P.; Khamkhrongmee, S.

    2015-05-01

    Electron paramagnetic resonance (EPR) spectroscopy was applied to characterize radiation-induced free radicals in the cotton fiber in order to determine the possibility for using cotton as a fortuitous dosimeter in accidental exposures to radiation. Cotton fabrics were irradiated at 0.1, 0.5, 1, 2, 10, 50 and 500 Gy using a 137Cs gamma source. The irradiated samples were then stored in the dark under controlled environmental conditions for 1, 15, 35 and 60 days. The EPR spectra were observed in samples using a Bruker EMX X-band spectrometer equipped with a TE102 rectangular cavity. The EPR signal intensities of irradiated samples were determined from peak-to-peak amplitudes of EPR spectra and compared to those of unirradiated samples. The following optimum parameters were used: 100 kHz modulation frequency, 9.84 GHz microwave frequency, 1.8 mT modulation amplitude, 1.0 mW microwave power, 655 ms time constant, 41 ms conversion time and 41.98 s sweep time. The EPR spectra of unirradiated samples showed a singlet line with g = 2.006 due to pre-existing stable organic radicals in the cotton fibers, whereas those of irradiated samples showed the same pattern with different signal intensities according to the doses. Irradiation increased the signal intensity in a dose dependent manner. The signal intensity exhibited an exponential decay with storage time from 1 to 60 days. Obviously, the degree of fading of EPR intensity did not depend on the absorbed dose from 0.1 - 50 Gy. The maximum fading was about 60% at 60 days of storage for irradiated samples at all doses. However, this post-irradiation signal appeared to be detectable for up to 60 days. The EPR study results indicated the potential of using cotton as a fortuitous dosimeter in radiological accidents.

  9. Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France.

    SciTech Connect

    Ward, Dann C.

    2011-09-01

    This document describes the personal nuclear accident dosimeter (PNAD) used by Sandia National Laboratories (SNL) and presents PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study held 20-23 September, 2010, at CEA Valduc, France. SNL PNADs were exposed in two separate irradiations from the CALIBAN reactor. Biases for reported neutron doses ranged from -15% to +0.4% with an average bias of -7.7%. PNADs were also exposed on the back side of phantoms to assess orientation effects.

  10. Radiation dosimeters

    DOEpatents

    Hoelsher, James W.; Hegland, Joel E.; Braunlich, Peter F.; Tetzlaff, Wolfgang

    1992-01-01

    Radiation dosimeters and dosimeter badges. The dosimeter badges include first and second parts which are connected to join using a securement to produce a sealed area in which at least one dosimeter is held and protected. The badge parts are separated to expose the dosimeters to a stimulating laser beam used to read dose exposure information therefrom. The badge is constructed to allow automated disassembly and reassembly in a uniquely fitting relationship. An electronic memory is included to provide calibration and identification information used during reading of the dosimeter. Dosimeter mounts which reduce thermal heating requirements are shown. Dosimeter constructions and production methods using thin substrates and phosphor binder-layers applied thereto are also taught.

  11. Wristwatch dosimeter

    DOEpatents

    Wolf, Michael A.; Waechter, David A.; Umbarger, C. John

    1986-01-01

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable with a conventional digital watch case having an additional aperture enabling the detector to receive radiation.

  12. Wristwatch dosimeter

    DOEpatents

    Wolf, M.A.; Waechter, D.A.; Umbarger, C.J.

    1986-08-26

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable with a conventional digital watch case having an additional aperture enabling the detector to receive radiation. 10 figs.

  13. Kevlar® as a Potential Accident Radiation Dosimeter for First Responders, Law Enforcement and Military Personnel.

    PubMed

    Romanyukha, Alexander; Trompier, François; Benevides, Luis A

    2016-08-01

    Today the armed forces and law enforcement personnel wear body armor, helmets, and flak jackets composed substantially of Kevlar® fiber to prevent bodily injury or death resulting from physical, ballistic, stab, and slash attacks. Therefore, there is a high probability that during a radiation accident or its aftermath, the Kevlar®-composed body armor will be irradiated. Preliminary study with samples of Kevlar® foundation fabric obtained from body armor used by the U.S. Marine Corps has shown that all samples evaluated demonstrated an EPR signal, and this signal increased with radiation dose. Based on these results, the authors predict that, with individual calibration, exposure at dose above 1 Gy can be reliably detected in Kevlar® samples obtained from body armor. As a result of these measurements, a post-event reconstruction of exposure dose can be obtained by taking various samples throughout the armor body and helmet worn by the same irradiated individual. The doses can be used to create a whole-body dose map that would be of vital importance in a case of a partial body or heterogeneous exposure.

  14. Citizen's dosimeter

    SciTech Connect

    Klemic, Gladys; Bailey, Paul; Breheny, Cecilia

    2008-09-02

    The present invention relates to a citizen's dosimeter. More specifically, the invention relates to a small, portable, personal dosimetry device designed to be used in the wake of a event involving a Radiological Dispersal Device (RDD), Improvised Nuclear Device (IND), or other event resulting in the contamination of large area with radioactive material or where on site personal dosimetry is required. The card sized dosimeter generally comprises: a lower card layer, the lower card body having an inner and outer side; a upper card layer, the layer card having an inner and outer side; an optically stimulated luminescent material (OSLM), wherein the OSLM is sandwiched between the inner side of the lower card layer and the inner side of the upper card layer during dosimeter radiation recording, a shutter means for exposing at least one side of the OSLM for dosimeter readout; and an energy compensation filter attached to the outer sides of the lower and upper card layers.

  15. Description and evaluation of the Hanford personnel dosimeter program from 1944 through 1989. [Contain Glossary

    SciTech Connect

    Wilson, R.H.; Fix, J.J.; Baumgartner, W.V.; Nichols, L.L.

    1990-09-01

    This report describes the evolution of personnel dosimeter technology at Hanford since the inception of Hanford operations in 1944. Each of the personnel dosimeter systems used by people working or visiting Hanford is described. In addition, the procedures used to calibrate and calculate dose for each of the dosimeter systems are described. The accuracy of the recorded dose, primarily whole body deep dose, for the different dosimeter systems is evaluated. The evaluation is based on an extensive review of historical literature, as well as a 1989 intercomparison study of all film dosimeters and performance testing of the thermoluminescent dosimeter, also conducted during 1989. 73 refs., 40 figs., 41 tabs.

  16. Seventh Personnel Dosimetry Intercomparison Study

    SciTech Connect

    Swaja, R.E.; Sims, C.S.; Greene, R.T.

    1981-12-01

    The Seventh Personnel Dosimetry Intercomparison Study was conducted March 31-April 10, 1981, at the Oak Ridge National Laboratory. Dosimeters from 34 participating agencies were mounted on anthropomorphic phantoms and exposed to a range of low-level dose equivalents (1.5-15.0mSv neutron and 0.1-2.8 mSv gamma) which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor, operating in the steady-state mode, served as the source of radiation for two equivalent sets of six separate exposures. Lucite and concrete shields along with the unshielded reactor provided three different neutron and gamma spectra for five of the exposures in each set. Results reported by the participating agencies showed that no single type of neutron dosimeter exhibited acceptable performance characteristics for all mixed-field environments encountered in this study. Film, TLD, and TLD-albed dosimeters were found to be inadequate for neutron dose equivalent measurements when large numbers of slow neutrons are present unless significant corrections are made to measured results. Track dosimeters indicated the least sensitivity to spectral characteristics, but did not always yield to the most accurate results. Gamma dose measurements showed that TLD-700 dosimeters produced significantly more accurate results than film dosimeters which tend to overestimate gamma doses in mixed radiation fields.

  17. RADIATION DOSIMETER

    DOEpatents

    Balkwell, W.R. Jr.; Adams, G.D. Jr.

    1960-05-10

    An improvement was made in the determination of amounts of ionizing radiation, particularly low-energy beta particles of less than 1000 rad total dose by means of fluid-phase dosimeter employing a stabilized-- sensitized ferrous-ferric colorimetric system in a sulphuric acid medium. The improvement in the dosimeter consists of adding to the ferrous-ferric system in concentrations of 10/sub -2/ to 10/sup -4/M an organic compound having one or more carboxylic or equivalent groups, such compounds being capable of chelating or complexing the iron ions in the solution. Suitable sensitizing and stabilizing agents are benzoic, phthalic, salicylic, malonic, lactic, maleic, oxalic, citric, succinic, phenolic tartaric, acetic, and adipic acid, as well as other compounds which are added to the solution alone or in certain combinations. As in conventional fluid-phase dosimeters, the absorbed dosage is correlated with a corresponding change in optical density at particular wavelengths of the solution.

  18. PERSONNEL DOSIMETER

    DOEpatents

    Birkhoff, R.D.; Hubbell, H.H. Jr.; Johnson, R.M.

    1959-02-24

    A personnel dosimeter sensitive to both gamma and beta radiation is described. The dosimeter consists of an electrical conductive cylinder having a wall thickness of substantially 7 milligrams per square centimeter and an electrode disposed axially within the cylinder and insulated therefrom to maintain a potential impressed between the electrode and the cylinder. A cylindrical perforated shield provided with a known percentage of void area is disposed concentrically about the cylinder. The shield is formed of a material which does not contain more than 15 percent of an element higher than atomic weight 13. The dose actually received is at most the gamma dose plus the beta dose indicated by discharge of the dosimeter divided by the known percentage.

  19. Composite material dosimeters

    DOEpatents

    Miller, Steven D.

    1996-01-01

    The present invention is a composite material containing a mix of dosimeter material powder and a polymer powder wherein the polymer is transparent to the photon emission of the dosimeter material powder. By mixing dosimeter material powder with polymer powder, less dosimeter material is needed compared to a monolithic dosimeter material chip. Interrogation is done with excitation by visible light.

  20. Thermoluminescence dosimeter

    DOEpatents

    Zendle, R.

    1983-11-03

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  1. Thermoluminescence dosimeter

    DOEpatents

    Zendle, Robert

    1985-01-01

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  2. LLNL Results from CALIBAN-PROSPERO Nuclear Accident Dosimetry Experiments in September 2014

    SciTech Connect

    Lobaugh, M. L.; Hickman, D. P.; Wong, C. W.; Wysong, A. R.; Merritt, M. J.; Heinrichs, D. P.; Topper, J. D.

    2015-05-21

    Lawrence Livermore National Laboratory (LLNL) uses thin neutron activation foils, sulfur, and threshold energy shielding to determine neutron component doses and the total dose from neutrons in the event of a nuclear criticality accident. The dosimeter also uses a DOELAP accredited Panasonic UD-810 (Panasonic Industrial Devices Sales Company of America, 2 Riverfront Plaza, Newark, NJ 07102, U.S.A.) thermoluminescent dosimetery system (TLD) for determining the gamma component of the total dose. LLNL has participated in three international intercomparisons of nuclear accident dosimeters. In October 2009, LLNL participated in an exercise at the French Commissariat à l’énergie atomique et aux énergies alternatives (Alternative Energies and Atomic Energy Commission- CEA) Research Center at Valduc utilizing the SILENE reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison at CEA Valduc, this time with exposures at the CALIBAN reactor (Hickman et al. 2011). This paper discusses LLNL’s results of a third intercomparison hosted by the French Institut de Radioprotection et de Sûreté Nucléaire (Institute for Radiation Protection and Nuclear Safety- IRSN) with exposures at two CEA Valduc reactors (CALIBAN and PROSPERO) in September 2014. Comparison results between the three participating facilities is presented elsewhere (Chevallier 2015; Duluc 2015).

  3. Pocket radiation dosimeter: dosimeter charger assembly

    DOEpatents

    Manning, F.W.

    1982-03-17

    This invention is a novel pocket-type radiation dosimeter comprising an electrometric radiation dosimeter and a charging circuit therefor. The instrument is especially designed to be amenable to mass production, to have a long shelf life, and to be compact, lightweight, and usable by the layman. The dosimeter proper may be of conventional design. The charging circuit includes a shake-type electrostatic generator, a voltage doubler for integrating generator output voltages of one polarity, and a switch operated by an external permanent magnet.

  4. Pocket radiation dosimeter--dosimeter charger assembly

    DOEpatents

    Manning, Frank W.

    1984-01-01

    This invention is a novel pocket-type radiation dosimeter comprising an electrometric radiation dosimeter and a charging circuit therefor. The instrument is especially designed to be amenable to mass production, to have a long shelf life, and to be compact, lightweight, and usable by the layman. The dosimeter proper may be of conventional design. The charging circuit includes a shake-type electrostatic generator, a voltage doubler for integrating generator output voltages of one polarity, and a switch operated by an external permanent magnet.

  5. Smart Radiological Dosimeter

    SciTech Connect

    Kosslow, William J.; Bandzuch, Gregory S.

    2004-07-20

    A radiation dosimeter providing an indication of the dose of radiation to which the radiation sensor has been exposed. The dosimeter contains features enabling the monitoring and evaluating of radiological risks so that a user can concentrate on the task at hand. The dosimeter provides an audible alarm indication that a predetermined time period has elapsed, an audible alarm indication reminding the user to check the dosimeter indication periodically, an audible alarm indicating that a predetermined accumulated dose has been prematurely reached, and an audible alarm indication prior or to reaching the 3/4 scale point.

  6. Transport and deposition of radionuclides after the Fukushima nuclear accident: international model inter-comparison in the framework of a WMO Task Team

    NASA Astrophysics Data System (ADS)

    Wotawa, Gerhard; Draxler, Roland; Arnold, Delia; Galmarini, Stefano; Hort, Matthew; Jones, Andrew; Leadbetter, Susan; Malo, Alain; Maurer, Christian; Rolph, Glenn; Saito, Kazuo; Servranckx, Rene; Shimbori, Toshiki; Solazzo, Efisio

    2013-04-01

    In the framework of a Task Team set up after the Fukushima accident sponsored by WMO, the atmospheric transport and deposition models (ATDMs) FLEXPART (Austria), HYSPLIT (U.S.), MLDP0 (Canada), NAME (UK) and RATM (Japan) were inter-compared. These models are well-known and widely used for emergency response activities. As alternative model input data, JMA made available a Meso-Analysis with 5 km/ 3 hour resolution, and a radar/rain gauge precipitation analysis with 1 km and 30 minutes resolution. To allow maximum flexibility regarding the release rates of key nuclides, the computations were based on the concept of source-receptor matrices, in this connection also called transfer coefficient matrices (TCM). The matrices are calculated every 3 hours after 11 March 2011 00 UTC, based on unit emissions, and thus can be overlaid with any present and future release scenario that becomes established. As computational species, the model considered tracers, depositing gases and depositing aerosols, allowing accounting for the range of substances emitted during a nuclear accident. The model comparison was based on observed deposition patterns of Cesium-137 in the Fukushima province as collected by MEXT/USDOE shortly after the accident, and a few available in situ stations measuring radioactive isotopes. To perform a statistical comparison, established parameters like correlation coefficient (r), fractional bias (FB) and figure of merit in space (FMS) were used. A further ensemble analysis was performed to determine what subset of model results out of all available would provide non-redundant information and thus is optimal to describe the transport and deposition during the accident. The investigation showed (i) that a TCM-based calculation approach has a lot of merits due to its flexibility, (ii) that models tended to perform better if they were run in improved resolution or directly with the Japanese Meso-analysis, (iii) that the model results depend on the selection of

  7. Wrist-watch dosimeter

    DOEpatents

    Wolf, M.A.; Waechter, D.A.; Umbarger, C.J.

    1982-04-16

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable within a conventional digital watch case having an additional aperture enabling the detector to receive radiation.

  8. ULTRASONIC NEUTRON DOSIMETER

    DOEpatents

    Truell, R.; de Klerk, J.; Levy, P.W.

    1960-02-23

    A neutron dosimeter is described which utilizes ultrasonic waves in the megacycle region for determination of the extent of neutron damage in a borosilicate glass through ultrasonic wave velocity and attenuation measurements before and after damage.

  9. Magnetic field dosimeter development

    SciTech Connect

    Lemon, D.K.; Skorpik, J.R.; Eick, J.L.

    1980-09-01

    In recent years there has been increased concern over potential health hazards related to exposure of personnel to magnetic fields. If exposure standards are to be established, then a means for measuring magnetic field dose must be available. To meet this need, the Department of Energy has funded development of prototype dosimeters at the Battelle Pacific Northwest Laboratory. This manual reviews the principle of operation of the dosimeter and also contains step-by-step instructions for its operation.

  10. Length of stain dosimeter

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    1994-01-01

    Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

  11. Fundamentals of Polymer Gel Dosimeters

    NASA Astrophysics Data System (ADS)

    McAuley, Kim B.

    2006-12-01

    The recent literature on polymer gel dosimetry contains application papers and basic experimental studies involving polymethacrylic-acid-based and polyacrylamide-based gel dosimeters. The basic studies assess the relative merits of these two most commonly used dosimeters, and explore the effects of tetrakis hydroxymethyl phosphonium chloride (THPC) antioxidant on dosimeter performance. Polymer gel dosimeters that contain THPC or other oxygen scavengers are called normoxic dosimeters, because they can be prepared under normal atmospheric conditions, rather than in a glove box that excludes oxygen. In this review, an effort is made to explain some of the underlying chemical phenomena that affect dosimeter performance using THPC, and that lead to differences in behaviour between dosimeters made using the two types of monomer systems. Progress on the development of new more effective and less toxic dosimeters is also reported.

  12. A survey of IAEA/WHO 60Co TLD postal dose intercomparison exercises during 1985-2003.

    PubMed

    Salman, Ahmad Syed; Mahmood, Khalid; Orfi, Saraj Din

    2005-07-01

    Results of the survey of IAEA/WHO Co postal dose intercomparison exercises in which the Secondary Standard Dosimetry Laboratory participated during the period 1985-2003 are presented. In 14 exercises spread over a period of 19 years, the deviation in therapy dose level measurements of the Secondary Standard Dosimetry Laboratory has never exceeded the International Atomic Energy Agency Dosimetry Laboratory acceptable levels of accuracy. The IAEA/WHO thermoluminescent dosimeter postal dose intercomparison service, the procedure for irradiation of thermoluminescent dosimeters, and the water absorbed dose determination are briefly described.

  13. Fact-finding Survey in Response to the Manipulation of Personal Alarm Dosimeter Collection Efficiency: Lessons Learned About Post-Emergency Radiation Protection from the TEPCO Fukushima Daiichi APP Accident.

    PubMed

    Yasui, Shojiro

    2015-01-01

    During emergency work at TEPCO Fukushima Daiichi Atomic Power Plant on December 1, 2011 a subcontractor demanded that its contracted workers cover their personal alarm dosimeters (PAD) with 3-cm-thick lead plates to lower dosimeter readings. As a response, the Ministry of Health, Labour and Welfare (MHLW) conducted a fact-finding survey to identify similar cases and devise measures to prevent a recurrence of this incident. To screen the suspected cases, the MHLW extracted: a) cases in which a PAD reading was at least 15% higher than the reading obtained from a radio-photolumine-scence dosimeter (RPD), where the dose was greater than 5 mSv in a month (1813 data points), and b) dose data in which PAD readings were less than 50% of the expected dose, where exposure dose may exceed 1 mSv in a day (56 workers, 17,148 data points). From these screenings, the MHLW identified 50 instances from TEPCO and nine primary contractors, including four general contractors, two plant manufacturers, and three plant maintenance companies as the subjects of the due diligence study of exposure data, including interviews. The results of the survey provide lessons that can also be applied to transition from emergency radiation protection to normal operation, as the application of emergency dose limits had ceased on December 16, 2011, in the affected plant. Based on the results of the survey, the MHLW provided administrative guidance documents to TEPCO and 37 primary contractors. The major points of these documents include: a) identification of recorded dose values by comparison of PAD readings to RPD readings, b) storage and management of RPDs and control badges, c) circulation management of PADs and access control to the affected plant, d) estimation of planned doses and setting of alarm values of PADs, e) actions to be taken by contractors if worker dose limits are reached, and f) physical measures to prevent recurrence of the incident.

  14. X-rays sensing properties of MEH-PPV, Alq₃ and additive components: a new organic dosimeter as a candidate for minimizing the risk of accidents of patients undergoing radiation oncology.

    PubMed

    Schimitberger, T; Ferreira, G R; Akcelrud, L C; Saraiva, M F; Bianchi, R F

    2013-01-01

    In this paper, we report our experimental design in searching a smart and easy-to-read dosimeter used to detect 6 MV X-rays for improving patient safety in radiation oncology. The device was based on an organic emissive solutions of poly(2-methoxy-5(2'-ethylhexyloxy)-p-phenylenevinylene) (MEH-PPV), aluminum-tris-(8-hydroxyquinoline) (Alq₃) and additive components which were characterized by UV-Vis absorption, photoluminescence and CIE color coordinate diagram. The optical properties of MEH-PPV/Alq₃ solutions have been examined as function of radiation dose over the range of 0-100 Gy. It has shown that MEH-PPV/Alq₃ solutions are specifically sensitive to X-rays, since the effect of radiation on this organic system is strongly correlated with the efficient spectral overlap between Alq₃ emission and the absorption of degraded MEH-PPV, which alters the color and photoemission of MEH-PPV/Alq₃ mixtures from red to yellow, and then to green. The rate of this change is more sensitive when MEH-PPV/Alq₃ is irradiated in the presence of benzoyl peroxide than when in the presence of hindered phenolic stabilizers, respectively, an accelerator and an inhibitor to activate or inhibit free radical formation. This gives rise to optimize the response curve of the dosimeter. It is clear from the experimental results that organic emissive semiconductors have potential to be used as dedicated and low-cost dosimeters to provide an independent check of beam output of a linear accelerator and therefore to give patients the opportunity to have information on the dose prescription or equipment-related problems a few minutes before being exposed to radiation.

  15. Fact-finding Survey in Response to the Manipulation of Personal Alarm Dosimeter Collection Efficiency: Lessons Learned About Post-Emergency Radiation Protection from the TEPCO Fukushima Daiichi APP Accident.

    PubMed

    Yasui, Shojiro

    2015-01-01

    During emergency work at TEPCO Fukushima Daiichi Atomic Power Plant on December 1, 2011 a subcontractor demanded that its contracted workers cover their personal alarm dosimeters (PAD) with 3-cm-thick lead plates to lower dosimeter readings. As a response, the Ministry of Health, Labour and Welfare (MHLW) conducted a fact-finding survey to identify similar cases and devise measures to prevent a recurrence of this incident. To screen the suspected cases, the MHLW extracted: a) cases in which a PAD reading was at least 15% higher than the reading obtained from a radio-photolumine-scence dosimeter (RPD), where the dose was greater than 5 mSv in a month (1813 data points), and b) dose data in which PAD readings were less than 50% of the expected dose, where exposure dose may exceed 1 mSv in a day (56 workers, 17,148 data points). From these screenings, the MHLW identified 50 instances from TEPCO and nine primary contractors, including four general contractors, two plant manufacturers, and three plant maintenance companies as the subjects of the due diligence study of exposure data, including interviews. The results of the survey provide lessons that can also be applied to transition from emergency radiation protection to normal operation, as the application of emergency dose limits had ceased on December 16, 2011, in the affected plant. Based on the results of the survey, the MHLW provided administrative guidance documents to TEPCO and 37 primary contractors. The major points of these documents include: a) identification of recorded dose values by comparison of PAD readings to RPD readings, b) storage and management of RPDs and control badges, c) circulation management of PADs and access control to the affected plant, d) estimation of planned doses and setting of alarm values of PADs, e) actions to be taken by contractors if worker dose limits are reached, and f) physical measures to prevent recurrence of the incident. PMID:25617063

  16. [Thermoluminescence Slab Dosimeter].

    PubMed

    Shinsho, Kiyomitsu; Koba, Yusuke; Tamatsu, Satoshi; Sakurai, Noboru; Wakabayashi, Genichiro; Fukuda, Kazusige

    2013-01-01

    In 1953 F. Daniels et al. used the property of thermoluminescence in dosimetry for the first time. Since then, numerous TLD have been developed. 2D TLD was investigated for the first time in 1972 by P Broadhead. However, due to excessive fading, difficulties with handling and the time required for measurements, development stalled. At the current time, the majority of TLD are used in small scale, localized dosimetry with a wide dynamic range and personal dosimeters for exposure management. Urushiyama et. al. have taken advantage of the commoditization of CCD cameras in recent years--making large area, high resolution imaging easier--to introduce and develop a 2D TLD. It is expected that these developments will give rise to a new generation of applications for 2D TL dosimetry. This paper introduces the "TL Slab Dosimeter" developed jointly by Urushiyama et. al. and our team, its measurement system and several typical usage scenarios.

  17. Dose equivalent neutron dosimeter

    DOEpatents

    Griffith, Richard V.; Hankins, Dale E.; Tomasino, Luigi; Gomaa, Mohamed A. M.

    1983-01-01

    A neutron dosimeter is disclosed which provides a single measurements indicating the amount of potential biological damage resulting from the neutron exposure of the wearer, for a wide range of neutron energies. The dosimeter includes a detecting sheet of track etch detecting material such as a carbonate plastic, for detecting higher energy neutrons, and a radiator layer containing conversion material such as .sup.6 Li and .sup.10 B lying adjacent to the detecting sheet for converting moderate energy neutrons to alpha particles that produce tracks in the adjacent detecting sheet. The density of conversion material in the radiator layer is of an amount which is chosen so that the density of tracks produced in the detecting sheet is proportional to the biological damage done by neutrons, regardless of whether the tracks are produced as the result of moderate energy neutrons striking the radiator layer or as the result of higher energy neutrons striking the sheet of track etch material.

  18. Dosimeter Badge Detects Hydrazines

    NASA Technical Reports Server (NTRS)

    Young, Rebecca C.; Travis, Joshua C.; Moore, Gerald; Rose-Pehrsson, Susan; Carver, Patricia; Brenner, Karen

    1993-01-01

    Disposable dosimeter badge indicates approximate cumulative exposure to hydrazine or monomethyl hydrazine in air. Indication is change in colors of both paper tapes; one coated with para-N, N-dimethylaminobenzaldehyde. Colors of exposed tapes compared with colors on two preprinted color wheels to obtain estimate of exposure. Badges help minimize risks associated with exposure of personnel to hydrazine or monomethyl hydrazine, or suspected carcinogens. Also used as stationary monitors by taping them on walls or equipment at strategic locations.

  19. Dosimeter Corporation's computer interfacing automatic dosimeter (CID) system

    SciTech Connect

    Bunker, A.S.

    1985-07-01

    This paper reports that the weakest links in most large-scale quartz-fiber direct-reading dosimeter (DRD) programs are the devices used to read the DRD's; that is, the people who are assigned the DRDs and the technicians who log results, rezero dosimeters, and test dosimeters. These reading devices cannot be programmed for consistent interpretation of DRD readings, and they are notoriously slow at performing readings. They also cannot be easily interfaced to computer-based systems. Ideally, these devices should be replaced or supplemented with machines that can offer better precision, speed, and software. Dosimeter Corporation's Computer Interfaced Automatic Dosimetry (CID) system is one such machine.

  20. Hanford personnel dosimeter supporting studies FY-1981

    SciTech Connect

    Not Available

    1982-08-01

    This report examined specific functional components of the routine external personnel dosimeter program at Hanford. Components studied included: dosimeter readout; dosimeter calibration; dosimeter field response; dose calibration algorithm; dosimeter design; and TLD chip acceptance procedures. Additional information is also presented regarding the dosimeter response to light- and medium-filtered x-rays, high energy photons and neutrons. This study was conducted to clarify certain data obtained during the FY-1980 studies.

  1. Ionization chamber dosimeter

    DOEpatents

    Renner, Tim R.; Nyman, Mark A.; Stradtner, Ronald

    1991-01-01

    A method for fabricating an ion chamber dosimeter collecting array of the type utilizing plural discrete elements formed on a uniform collecting surface which includes forming a thin insulating layer over an aperture in a frame having surfaces, forming a predetermined pattern of through holes in the layer, plating both surfaces of the layer and simultaneously tilting and rotating the frame for uniform plate-through of the holes between surfaces. Aligned masking and patterned etching of the surfaces provides interconnects between the through holes and copper leads provided to external circuitry.

  2. PERSONNEL NEUTRON DOSIMETER

    DOEpatents

    Fitzgerald, J.J.; Detwiler, C.G. Jr.

    1960-05-24

    A description is given of a personnel neutron dosimeter capable of indicating the complete spectrum of the neutron dose received as well as the dose for each neutron energy range therein. The device consists of three sets of indium foils supported in an aluminum case. The first set consists of three foils of indium, the second set consists of a similar set of indium foils sandwiched between layers of cadmium, whereas the third set is similar to the second set but is sandwiched between layers of polyethylene. By analysis of all the foils the neutron spectrum and the total dose from neutrons of all energy levels can be ascertained.

  3. Pistol-shaped dosimeter charger

    DOEpatents

    Maples, Robert A.

    1985-01-01

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  4. Pistol-shaped dosimeter charger

    SciTech Connect

    Maples, R.A.

    1985-01-15

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  5. Pistol-shaped dosimeter charger

    DOEpatents

    Maples, R.A.

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  6. A new radiochromic dosimeter film

    NASA Astrophysics Data System (ADS)

    Sidney, L. N.; Lynch, D. C.; Willet, P. S.

    By employing acid-sensitive leuco dyes in a chlorine-containing polymer matrix, a new radiochromic dosimeter film has been developed for gamma, electron beam, and ultraviolet radiation. These dosimeter films undergo a color change from colorless to royal blue, red fuchsia, or black, depending on dye selection, and have been characterized using a visible spectrophotometer over an absorbed dose range of 1 to 100 kGy. The primary features of the film are improved color stability before and after irradiation, whether stored in the dark or under artificial lights, and improved moisture resistance. The effects of absorbed dose, dose rate, and storage conditions on dosimeter performance are discussed. The dosimeter material may be produced as a free film or coated onto a transparent substrate and optionally backed with adhesive. Potential applications for these materials include gamma sterilization indicator films for food and medical products, electron beam dosimeters, and in-line radiation monitors for electron beam and ultraviolet processing.

  7. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, R.B.; Tyree, W.H.

    1982-03-03

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  8. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, Roger B.; Tyree, William H.

    1984-12-18

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  9. Thermoluminescence dosimeter reader

    SciTech Connect

    Miyake, S.; Miura, N.

    1984-10-30

    A thermoluminescence dosimeter reader having a heater for heating a thermoluminescence element, a light measuring circuit for measuring circuit for measuring the intensity of the thermoluminescence emanated from the element when it is heated and a display device for displaying the reading of the dosage of radiation to which the element is exposed according to the intensity of the thermoluminescence is provided with a dosage information inputting means which outputs an electric signal having a value representing a predetermined reference dosage of radiation, a calculating means for calculating a calibration constant which is the ratio between the value of the electric signal and the output value of the light measuring circuit which is the measured value of the dosage of radiation of a reference thermoluminescence element which is exposed to the predetermined reference dosage of radiation, and a memory means for memorizing the calibration constant.

  10. Miniature spectrally selective dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr. (Inventor)

    1980-01-01

    A miniature spectrally selective dosimeter capable of measuring selected bandwidths of radiation exposure on small mobile areas is described. This is achieved by the combination of photovoltaic detectors, electrochemical integrators (E-cells) and filters in a small compact case which can be easily attached in close proximity to and substantially parallel to the surface being measured. In one embodiment two photovoltaic detectors, two E-cells, and three filters are packaged in a small case with attaching means consisting of a safety pin. In another embodiment, two detectors, one E-cell, three filters are packaged in a small case with attaching means consisting of a clip to clip over a side piece of an eye glass frame.

  11. Characterization of metal oxide semiconductor field effect transistor dosimeters for application in clinical mammography.

    PubMed

    Benevides, Luis A; Hintenlang, David E

    2006-02-01

    Five high-sensitivity metal oxide semiconductor field effect transistor dosimeters in the TN-502 and 1002 series (Thomson Nielsen Electronics Ltd., 25B, Northside Road, Ottawa, ON K2H8S1, Canada) were evaluated for use in the mammography x-ray energy range (22-50 kVp) as a tool to assist in the documentation of patient specific average glandular dose. The dosimeters were interfaced with the Patient Dose Verification System, model No. TN-RD 15, which consisted of a dosimeter reader and up to four dual bias power supplies. Two different dual bias power supplies were evaluated in this study, model No. TN-RD 22 in high-sensitivity mode and a very-high sensitivity prototype. Each bias supply accommodates up to five dosimeters for 20 dosimeters per system. Sensitivity of detectors, defined as the mV/C kg(-1), was measured free in air with the bubble side of the dosimeter facing the x-ray field with a constant exposure. All dosimeter models' angular response showed a marked decrease in response when oriented between 120 degrees and 150 degrees and between at 190 degrees and 220 degrees relative to the incident beam. Sensitivity was evaluated for Mo/Mo, Mo/Rh, and Rh/Rh target-filter combinations. The individual dosimeter model sensitiVity was 4.45 x 10(4) mV/C kg(-1) (11.47 mV R(-1)) for TN-502RDS(micro); 5.93 x 10(4) mV per C kg(-1) (15.31 mV R(-1)) for TN-1002RD; 6.06 x 10(4) mV/C kg(-1) (15.63 mV R(-1)) for TN-1002RDI; 9.49 x 10(4) mV per C kg(-1) (24.49 mV R(-1)) for TN-1002RDM (micro); and 11.20 x 10(4) mV/C kg(-1) (28.82 mV R(-1)) for TN-1002RDS (micro). The energy response is presented and is observed to vary with dosimeter model, generally increasing with tube potential through the mammography energy range. An intercomparison of the high-sensitivity mode of TN-RD-22 was made to the very-high sensitivity bias power supply using a Mo/Mo target-filter. The very-high sensitivity-bias power supply increased dosimeter response by 1.45 +/- 0.04 for dosimeter models TN

  12. Brachytherapy dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F. C.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2015-07-01

    In-vivo and in-situ measurement of the radiation dose administered during brachytherapy faces several technical challenges, requiring a very compact, tissue-equivalent, linear and highly sensitive dosimeter, particularly in low-dose rate brachytherapy procedures, which use radioactive seeds with low energy and low dose deposition rate. In this work we present a scintillating optical fiber dosimeter composed of a flexible sensitive probe and a dedicated electronic readout system based on silicon photomultiplier photodetection, capable of operating both in pulse and current modes. The performance of the scintillating fiber optic dosimeter was evaluated in low energy regimes, using an X-ray tube operating at voltages of 40-50 kV and currents below 1 mA, to assess minimum dose response of the scintillating fiber. The dosimeter shows a linear response with dose and is capable of detecting mGy dose variations like an ionization chamber. Besides fulfilling all the requirements for a dosimeter in brachytherapy, the high sensitivity of this device makes it a suitable candidate for application in low-dose rate brachytherapy. According to Peralta and Rego [1], the BCF-10 and BCF-60 scintillating optical fibers used in dosimetry exhibit high variations in their sensitivity for photon beams in the 25-100 kVp energy range. Energy linearity for energies below 50 keV needs to be further investigated, using monochromatic X-ray photons.

  13. Dose-equivalent neutron dosimeter

    DOEpatents

    Griffith, R.V.; Hankins, D.E.; Tomasino, L.; Gomaa, M.A.M.

    1981-01-07

    A neutron dosimeter is disclosed which provides a single measurement indicating the amount of potential biological damage resulting from the neutron exposure of the wearer, for a wide range of neutron energies. The dosimeter includes a detecting sheet of track etch detecting material such as a carbonate plastic, for detecting higher energy neutrons, and a radiator layer contaning conversion material such as /sup 6/Li and /sup 10/B lying adjacent to the detecting sheet for converting moderate energy neutrons to alpha particles that produce tracks in the adjacent detecting sheet.

  14. Spectrophotometry of PRESAGETM polyurethane dosimeters

    NASA Astrophysics Data System (ADS)

    Krstajic, N.; Wai, P.; Adamovics, J.; Doran, S.

    2004-01-01

    Preliminary optical density results on irradiated PRESAGE dosimeter are outlined in this article. PRESAGE is a solid dosimeter, based on a clear polyurethane combined with the leuco-dye leuco-malachite green. The purpose of these measurements was a) to obtain spectra for optimizing the wavelength of a new light source for the equipment and b) to obtain a dose-response relation. 10 PRESAGE cuvettes were given uniform doses from 0.1 to 40 Gy and later read out by spectrophotometer. The instrument used was CAMSPEC M350 Double Beam Spectrophotometer.

  15. Miniature personal UV solar dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr.

    1981-01-01

    Small light-powered meter measures accumulated radiation in ultraviolet or other selected regions. Practical advantages are device's low cost, small size, accuracy, and adaptability to specific wave-band measurements. Medical applications include detection of skin cancer, vitamin D production, and jaundice. Dosimeter also measures sunlight for solar energy designs, agriculture and meteorology, and monitors stability of materials and environmental and occupational lighting.

  16. Eleventh ORNL personnel dosimetry intercomparison study, May 22-23, 1985

    SciTech Connect

    Swaja, R.E.; Oyan, R.; Sims, C.S.

    1986-07-01

    The Eleventh Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory (ORNL) during May 22-23, 1985. Dosimeter badges from 44 participating organizations were mounted on Lucite block phantoms and exposed to four mixed-radiation fields with neutron dose equivalents around 5 mSv and gamma dose equivalents between 0.1 and 0.7 mSv. Results of this study indicated that no participants had difficulty obtaining measurable indication of neutron exposure at the provided dose equivalent levels, and very few had difficulty obtaining indication of gamma exposure at dose equivalents as low as 0.10 mSv. Average neutron results for all dosimeter types were within 20% of reference values with no obvious spectrum dependence. Different dosimeter types (albedo, direct interaction TLD, film, recoil track, and combination albedo-track) with 10 or more reported measurements provided average results within 35% of reference values for all spectra. With regard to precision, about 80% of the reported neutron results had single standard deviations within 10% at the means which indicates that precision is not a problem relative to accuracy for most participants. Average gamma results were greater than reference values by factors of 1.07 to 1.52 for the four exposures with TLD systems being more accurate than film. About 80% of all neutron results and 67% of all gamma results met regulatory standards for measurement accuracy and approximately 70% of all neutron data satisfied national dosimetry accreditation criteria for accuracy plus precision. In general, neutron dosimeter performance observed in this intercomparison was much improved compared to that observed in the prior studies while gamma dosimeter performance was about the same.

  17. Personnel dosimetry intercomparison studies at the Health Physics Research Reactor: a summary (1974-80).

    PubMed

    Sims, C S; Swaja, R E

    1982-01-01

    Six personnel dosimetry intercomparison studies using the Health Physics Research Reactor at the Oak Ridge National Laboratory were conducted between 1974 and 1980. These studies allowed participants to test their neutron and gamma-ray dosimeters under a variety of mixed-field spectral conditions and to compare their results with those of others making measurements under identical conditions. Fifty-eight participant organizations, about half of which participated in more than one study, made approx. 2000 measurements of the neutron and gamma-dose-equivalent. Dose equivalents in the 0.1-12 mSv (i.e. 10-1200 mrem) range were determined for five different shielded reactor spectra using three basic types of dosimeters (thermoluminescent albedo, nuclear emulsion film and track etch) for neutron measurements and two basic types (film and thermoluminescent dosimeters) for the gamma-measurements. The data from the six studies are summarized, analyzed and explained. Intercomparison of the participants' results and consideration of reference dosimetry allows several conclusions to be made relative to the status of and trends in personnel neutron and gamma-ray dosimetry. PMID:7056645

  18. RADIATION DOSIMETER AND DOSIMETRIC METHODS

    DOEpatents

    Taplin, G.V.

    1958-10-28

    The determination of ionizing radiation by means of single fluid phase chemical dosimeters of the colorimetric type is presented. A single fluid composition is used consisting of a chlorinated hydrocarbon, an acidimetric dye, a normalizer and water. Suitable chlorinated hydrocarbons are carbon tetrachloride, chloroform, trichloroethylene, trichlorethane, ethylene dichioride and tetracbloroethylene. Suitable acidimetric indicator dyes are phenol red, bromcresol purple, and creosol red. Suitable normallzers are resorcinol, geraniol, meta cresol, alpha -tocopberol, and alpha -naphthol.

  19. Fast-neutron solid-state dosimeter

    DOEpatents

    Kecker, K.H.; Haywood, F.F.; Perdue, P.T.; Thorngate, J.H.

    1975-07-22

    This patent relates to an improved fast-neutron solid-state dosimeter that does not require separation of materials before it can be read out, that utilizes materials that do not melt or otherwise degrade at about 300$sup 0$C readout temperature, that provides a more efficient dosimeter, and that can be reused. The dosimeters are fabricated by intimately mixing a TL material, such as CaSO$sub 4$:Dy, with a powdered polyphenyl, such as p-sexiphenyl, and hot- pressing the mixture to form pellets, followed by out-gassing in a vacuum furnace at 150$sup 0$C prior to first use dosimeters. (auth)

  20. Early development and characterization of a DNA-based radiation dosimeter

    NASA Astrophysics Data System (ADS)

    Avarmaa, Kirsten A.

    It is the priority of first responders to minimize damage to persons and infrastructure in the case of a nuclear emergency due to an accident or deliberate terrorist attack -- if this emergency includes a radioactive hazard, first responders require a simple-to-use, accurate and complete dosimeter for radiation protection purposes in order to minimize the health risk to these individuals and the general population at large. This work consists of the early evaluation of the design and performance of a biologically relevant dosimeter which uses DNA material that can respond to the radiation of any particle type. The construct consists of fluorescently tagged strands of DNA. The signalling components of this dosimeter are also investigated for their sensitivity to radiation damage and light exposure. The dual-labelled dosimeter that is evaluated in this work gave a measurable response to gamma radiation at dose levels of 10 Gy for the given detector design and experimental setup. Further testing outside of this work confirmed this finding and indicated a working range of 100 mGy to 10 Gy using a custom-built fluorimeter as part of a larger CRTI initiative. Characterization of the chromatic components of the dosimeter showed that photobleaching is not expected to have an effect on dosimeter performance, but that radiation can damage the non-DNA signalling components at higher dose levels, although this damage is minimal at lower doses over the expected operating ranges. This work therefore describes the early steps in the quantification of the behaviour of the DNA dosimeter as a potential biologically-based device to measure radiation dose.

  1. Portable neutron spectrometer and dosimeter

    DOEpatents

    Waechter, David A.; Erkkila, Bruce H.; Vasilik, Dennis G.

    1985-01-01

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  2. Portable neutron spectrometer and dosimeter

    DOEpatents

    Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  3. BETA-GAMMA PERSONNEL DOSIMETER

    DOEpatents

    Davis, D.M.; Gupton, E.D.; Hart, J.C.; Hull, A.P.

    1961-01-17

    A personnel dosimeter is offered which is sensitive to both gamma and soft beta radiations from all directions within a hemisphere. The device is in the shape of a small pill box which is worn on a worker-s wrist. The top and sides of the device are provided with 50 per cent void areas to give 50 per cent response to the beta rays and complete response to the gamma rays. The device is so constructed as to have a response which will approximate the dose received by the basal layer of the human epidermis.

  4. SOIL moisture data intercomparison

    NASA Astrophysics Data System (ADS)

    Kerr, Yann; Rodriguez-Frenandez, Nemesio; Al-Yaari, Amen; Parens, Marie; Molero, Beatriz; Mahmoodi, Ali; Mialon, Arnaud; Richaume, Philippe; Bindlish, Rajat; Mecklenburg, Susanne; Wigneron, Jean-Pierre

    2016-04-01

    The Soil Moisture and Ocean Salinity satellite (SMOS) was launched in November 2009 and started delivering data in January 2010. Subsequently, the satellite has been in operation for over 6 years while the retrieval algorithms from Level 1 to Level 2 underwent significant evolutions as knowledge improved. Other approaches for retrieval at Level 2 over land were also investigated while Level 3 and 4 were initiated. In this présentation these improvements are assessed by inter-comparisons of the current Level 2 (V620) against the previous version (V551) and new products either using neural networks or Level 3. In addition a global evaluation of different SMOS soil moisture (SM) products is performed comparing products with those of model simulations and other satellites (AMSR E/ AMSR2 and ASCAT). Finally, all products were evaluated against in situ measurements of soil moisture (SM). The study demonstrated that the V620 shows a significant improvement (including those at level1 improving level2)) with respect to the earlier version V551. Results also show that neural network based approaches can yield excellent results over areas where other products are poor. Finally, global comparison indicates that SMOS behaves very well when compared to other sensors/approaches and gives consistent results over all surfaces from very dry (African Sahel, Arizona), to wet (tropical rain forests). RFI (Radio Frequency Interference) is still an issue even though detection has been greatly improved while RFI sources in several areas of the world are significantly reduced. When compared to other satellite products, the analysis shows that SMOS achieves its expected goals and is globally consistent over different eco climate regions from low to high latitudes and throughout the seasons.

  5. Calorimetry of electron beams and the calibration of dosimeters at high doses

    NASA Astrophysics Data System (ADS)

    Humphreys, J. C.; McLaughlin, W. L.

    Graphite or metal calorimeters are used to make absolute dosimetric measurements of high-energy electron beams. These calibrated beams are then used to calibrate several types of dosimeters for high-dose applications such as medical-product sterilization, polymer modification, food processing, or electronic-device hardness testing. The electron beams are produced either as continuous high-power beams at approximately 4.5 MeV by d.c. type accelerators or in the energy range of approximately 8 to 50 MeV using pulsed microwave linear accelerators (linacs). The continuous beams are generally magnetically scanned to produce a broad, uniform radiation environment for the processing of materials of extended lateral dimensions. The higher-energy pulsed beams may also be scanned for processing applications or may be used in an unscanned, tightly-focused mode to produce maximum absorbed dose rates such as may be required for electronic-device radiation hardness testing. The calorimeters are used over an absorbed dose range of 10 2 to 10 4 Gy. Intercomparison studies are reported between National Institute of Standards and Technology (NIST) and UK National Physical Laboratory (NPL) graphite disk calorimeters at high doses, using the NPL 10-MeV linac, and agreement was found within 1.5%. It was also shown that the electron-beam responses of radiochromic film dosimeters and alanine pellet dosimeters can be accurately calibrated by comparison with calorimeter readings.

  6. Dosimeter and method for using the same

    DOEpatents

    Warner, Benjamin P.; Johns, Deidre M.

    2003-06-24

    A very sensitive dosimeter that detects ionizing radiation is described. The dosimeter includes a breakable sealed container. A solution of a reducing agent is inside the container. The dosimeter has an air-tight dosimeter body with a transparent portion and an opaque portion. The transparent portion includes a transparent chamber that holds the breakable container with the reducing agent. The opaque portion includes an opaque chamber that holds an emulsion of silver salt (AgX) selected from silver chloride, silver bromide, silver iodide, and combinations of them. A passageway in the dosimeter provides fluid communication between the transparent chamber and the opaque chamber. The dosimeter may also include a chemical pH indicator in the breakable container that provides a detectable color change to the solution for a pH of about 3-10. The invention also includes a method of detecting ionizing radiation that involves producing the dosimeter, breaking the breakable container, allowing the solution to flow through the passageway and contact the emulsion, detecting any color change in the solution and using the color change to determine a radiation dosage.

  7. Comparative study of some new EPR dosimeters

    NASA Astrophysics Data System (ADS)

    Alzimami, K. S.; Maghraby, Ahmed M.; Bradley, D. A.

    2014-02-01

    Investigations have been made of four new radiation dosimetry EPR candidates from the same family of materials: sulfamic acid, sulfanillic acid, homotaurine, and taurine. Mass energy attenuation coefficients, mass stopping power values and the time dependence of the radiation induced radicals are compared. Also investigated are the microwave saturation behavior and the effect of applied modulation amplitude on both peak-to-peak line width (WPP) and peak-to-peak signal height (HPP). The dosimeters are characterized by simple spectra and stable radiation-induced radicals over reasonable durations, especially in taurine dosimeters. Sulfamic acid dosimeters possessed the highest sensitivity followed by taurine and homotaurine and sulfanillic.

  8. Fiber-type dosimeter with improved illuminator

    DOEpatents

    Fox, R.J.

    1985-12-23

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  9. Diffusion properties of a radiochromic hydrogel dosimeter

    NASA Astrophysics Data System (ADS)

    Skyt, P. S.; Kinnari, T. S.; Wahlstedt, I.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2013-06-01

    The aim of this study was to investigate the diffusion properties of a radiochromic hydrogel dosimeter based on leuco malachite green dye in a gelatine matrix. One half of each dosimeter was irradiated while the other half was left un-irradiated creating dose gradients over which diffusion could be investigated. Read-out of the optical response was performed with a high-resolution optical scanner. The dosimeters were found to exhibit a low diffusion rate but a high auto-oxidation level leading to a fading of the contrast in the dose response with time.

  10. Fiber-type dosimeter with improved illuminator

    DOEpatents

    Fox, Richard J.

    1987-01-01

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  11. Performance criteria for dosimeter angular response

    SciTech Connect

    Roberson, P.L.; Fox, R. A.; Cummings, F. M.; McDonald, J. C.; Jones, K.L.

    1988-06-01

    This report provides criteria for evaluating the response of personnel dosimeters to radiation at nonperpendicular incidence. The US Department of Energy Laboratory Accreditation Program (DOELAP) ensures that dosimetry systems at DOE facilities meet acceptable standards for precision and accuracy. In the past, these standards were limited to tests for system variability, energy dependence, and level of detection. The proposed criteria will broaden the scope of DOELAP to include the angular response of personnel dosimeters. Because occupational exposures in the workplace are rarely due to radiation from only one direction, dosimeters must accurately assign individual dose equivalent from irradiation at any forward angle of incidence. Including an angular response criterion in DOELAP would improve the quality of personnel monitoring provided that the criterion is developed from appropriate dose quantities. This report provides guidance for assigning individual dose equivalents for radiation fields at nonperpendicular incidence to the dosimeter. 21 refs., 10 figs., 10 tabs.

  12. Polymer gel dosimeter based on itaconic acid.

    PubMed

    Mattea, Facundo; Chacón, David; Vedelago, José; Valente, Mauro; Strumia, Miriam C

    2015-11-01

    A new polymeric dosimeter based on itaconic acid and N, N'-methylenebisacrylamide was studied. The preparation method, compositions of monomer and crosslinking agent and the presence of oxygen in the dosimetric system were analyzed. The resulting materials were irradiated with an X-ray tube at 158cGy/min, 226cGymin and 298cGy/min with doses up to 1000Gy. The dosimeters presented a linear response in the dose range 75-1000Gy, sensitivities of 0.037 1/Gyat 298cGy/min and an increase in the sensitivity with lower dose rates. One of the most relevant outcomes in this study was obtaining different monomer to crosslinker inclusion in the formed gel for the dosimeters where oxygen was purged during the preparation method. This effect has not been reported in other typical dosimeters and could be attributed to the large differences in the reactivity among these species.

  13. The LLNL CR-39 personnel neutron dosimeter

    SciTech Connect

    Hankins, D.E.; Homann, S.; Westermark, J.

    1987-09-29

    We developed a personnel neutron dosimetry system based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This CR-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. 3 refs., 4 figs.

  14. Dose mapping of the rectal wall during brachytherapy with an array of scintillation dosimeters

    SciTech Connect

    Cartwright, L. E.; Suchowerska, N.; Yin, Y.; Lambert, J.; Haque, M.; McKenzie, D. R.

    2010-05-15

    Purpose: In pelvic brachytherapy treatments, the rectum is an organ at risk. The authors have developed an array of scintillation dosimeters suitable for in vivo use that enables quality assurance of the treatment delivery and provides an alert to potential radiation accidents. Ultimately, this will provide evidence to direct treatment planning and dose escalation and correlate dose with the rectal response. Methods: An array of 16 scintillation dosimeters in an insertable applicator has been developed. The dosimeters were calibrated simultaneously in a custom designed circular jig before use. Each dosimeter is optically interfaced to a set of pixels on a CCD camera located outside the treatment bunker. A customized software converts pixel values into dose rate and accumulates dose for presentation during treatment delivery. The performance of the array is tested by simulating brachytherapy treatments in a water phantom. The treatment plans were designed to deliver a known dose distribution on the surface of the rectal applicator, assumed to represent the dose to the rectal wall. Results: The measured doses were compared to those predicted by the treatment plan and found to be in agreement to within the uncertainty in measurement, usually within 3%. The array was also used to track the progression of the source as it moved along the catheter. The measured position was found to agree with the position reported by the afterloader to within the measurement uncertainty, usually within 2 mm. Conclusions: This array is capable of measuring the actual dose received by each region of the rectal wall during brachytherapy treatments. It will provide real time monitoring of treatment delivery and raise an alert to a potential radiation accident. Real time dose mapping in the clinical environment will give the clinician additional confidence to carry out dose escalation to the tumor volume while avoiding rectal side effects.

  15. Intercomparison of Retrospective Radon Detectors

    SciTech Connect

    Field, R W.; Steck, D J.; Parkhurst, Maryann ); Mahaffey, Judith A. ); Alavanja, M C.

    1998-11-01

    We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, (2) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass implanted polonium activities, and (3) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted Po-210 activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type.

  16. Environmental dosimeter of the thermoluminescent type

    DOEpatents

    Eichner, F.N.; Kocher, L.F.

    1974-01-29

    A dosimeter for accurately monitoring normally low-energy radiation including a thermoluminescent CaF phosphor enclosed within a tantalum capsule is described. The tantalum acts as a filter to weaken the measured dose due to photons having energies below about 0.2 MeV. Tantalum end caps are maintained on the capsule body by a polyolefin sheath formed from heat-contractable tubing. After exposing the dosimeter to environmental radiation, it is placed in a shielded chamber for about 24 h and subsequently annealed at about 80 deg C to release radiation energy accumulated in low-temperature traps. The dosimeter is then disassembled and the phosphors photometrically read at temperatures about 50 deg C to determine the absorbed radiation dose. (Official Gazette)

  17. Solid state neutron dosimeter for space applications

    SciTech Connect

    Nagarkar, V.; Entine, G.; Stoppel, P.; Cirignano, L. ); Swinehart, P. )

    1992-08-01

    One of the most important contributions to the radiation exposure of astronauts engaged in space flight is the significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Under NASA sponsorship, the authors are developing a solid state neutron sensor capable of being incorporated into a very compact, flight instrument to provide high quality real time measurement of this important radiation flux. The dosimeter uses a special, high neutron sensitivity, PIN diode that is insensitive t the other forms of ionizing radiation. The dosimeter will have the ability to measure and record neutron dose over a range of 50 microgray to tens of milligrays (5 millirads to several rads) over a flight of up to 30 days. the performance characteristics of the PIN diode with a detailed description of the overall dosimeter is presented. in this paper.

  18. Do saccharide doped PAGAT dosimeters increase accuracy?

    NASA Astrophysics Data System (ADS)

    Berndt, B.; Skyt, P. S.; Holloway, L.; Hill, R.; Sankar, A.; De Deene, Y.

    2015-01-01

    To improve the dosimetric accuracy of normoxic polyacrylamide gelatin (PAGAT) gel dosimeters, the addition of saccharides (glucose and sucrose) has been suggested. An increase in R2-response sensitivity upon irradiation will result in smaller uncertainties in the derived dose if all other uncertainties are conserved. However, temperature variations during the magnetic resonance scanning of polymer gels result in one of the highest contributions to dosimetric uncertainties. The purpose of this project was to study the dose sensitivity against the temperature sensitivity. The overall dose uncertainty of PAGAT gel dosimeters with different concentrations of saccharides (0, 10 and 20%) was investigated. For high concentrations of glucose or sucrose, a clear improvement of the dose sensitivity was observed. For doses up to 6 Gy, the overall dose uncertainty was reduced up to 0.3 Gy for all saccharide loaded gels compared to PAGAT gel. Higher concentrations of glucose and sucrose deteriorate the accuracy of PAGAT dosimeters for doses above 9 Gy.

  19. System for use with solid state dosimeter

    DOEpatents

    Miller, S.D.; McDonald, J.C.; Eichner, F.N.; Tomeraasen, P.L.

    1990-09-04

    The present invention constitutes a system for determining the amounts of ionizing radiation to which dosimeters using thermoluminescent materials have been exposed. In accordance with this system, the thermoluminescent materials which comprise the dosimeters are first cooled by contact with a cryogenic substance such as liquefied nitrogen. The thermoluminescent materials are then optically stimulated by exposure to ultraviolet light. Thereafter, the amounts of visible light emitted by the thermoluminescent materials are detected and counted as the materials are allowed to warm up to room temperature. The amounts of luminescence exhibited by the materials are related to radiation exposure and provide a sensitive measure of radiation dosage. It has been discovered that the above procedure is most effective when heavily doped thermoluminescent materials are used and that the procedure allows many useful plastic materials to now be employed in dosimeter constructions. 3 figs.

  20. System for use with solid state dosimeter

    DOEpatents

    Miller, Steven D.; McDonald, Joseph C.; Eichner, Fred N.; Tomeraasen, Paul L.

    1990-01-01

    The present invention constitutes a system for determining the amounts of ionizing radiation to which dosimeters using thermoluminescent materials have been exposed. In accordance with this system, the thermoluminescent materials which comprise the dosimeters are first cooled by contact with a cryogenic substance such as liquified nitrogen. The thermoluminescent materials are then optically stimulated by exposure to ultraviolet light. Thereafter, the amounts of visible light emitted by the thermoluminescent materials are detected and counted as the materials are allowed to warm up to room temperature. The amounts of luminescence exhibited by the materials are related to radiation exposure and provide a sensitive measure of radiation dosage. It has been discovered that the above procedure is most effective when heavily doped thermoluminescent materials are used and that the procedure allows many useful plastic materials to now be employed in dosimeter constructions.

  1. Chemical Dosimeter Tube With Coaxial Sensing Rod

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E.

    1993-01-01

    Improved length-of-stain (LOS) chemical dosimeter indicates total dose of chemical vapor in air. Made with rods and tubes of various diameters to obtain various sensitivities and dynamic ranges. Sensitivity larger and dose range smaller when more room for diffusion in gap between tube and rod. Offers greater resistance to changing of color of exposed dye back to color of unexposed condition, greater sensitivity, and higher degree of repeatability. Developed to measure doses of gaseous HCI, dosimeter modified by use of other dyes to indicate doses of other chemical vapors.

  2. Fiber optic dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2014-08-01

    A small dimension, real-time readout dosimeter is desirable for specific applications in medical physics as for example, dose measurement in prostate brachytherapy. This particular radiotherapy procedure consists in the permanent deposition of low energy, low-dose and low-dose rate small sized radioactive seeds. We developed a scintillating fiber optic based dosimeter suitable for in-vivo, real-time low dose and low dose rate measurements. Due to the low scintillation light produced in the scintillating fiber, a high sensitive and high gain light detector is required. The Silicon Photomultipliers are an interesting option that allowed us to obtain good results in our studies.

  3. Radiotherapy Accidents

    NASA Astrophysics Data System (ADS)

    Mckenzie, Alan

    A major benefit of a Quality Assurance system in a radiotherapy centre is that it reduces the likelihood of an accident. For over 20 years I have been the interface in the UK between the Institute of Physics and Engineering in Medicine and the media — newspapers, radio and TV — and so I have learned about radiotherapy accidents from personal experience. In some cases, these accidents did not become public and so the hospital cannot be identified. Nevertheless, lessons are still being learned.

  4. Models and Measurements Intercomparison 2

    NASA Technical Reports Server (NTRS)

    Park, Jae H. (Editor); Ko, Malcolm K. W. (Editor); Jackman, Charles H. (Editor); Plumb, R. Alan (Editor); Kaye, Jack A. (Editor); Sage, Karen H. (Editor)

    1999-01-01

    Models and Measurement Intercomparison II (MM II) summarizes the intercomparison of results from model simulations and observations of stratospheric species. Representatives from twenty-three modeling groups using twenty-nine models participated in these MM II exercises between 1996 and 1999. Twelve of the models were two- dimensional zonal-mean models while seventeen were three-dimensional models. This was an international effort as seven were from outside the United States. Six transport experiments and five chemistry experiments were designed for various models. Models participating in the transport experiments performed simulations of chemically inert tracers providing diagnostics for transport. The chemistry experiments involved simulating the distributions of chemically active trace cases including ozone. The model run conditions for dynamics and chemistry were prescribed in order to minimize the factors that caused differences in the models. The report includes a critical review of the results by the participants and a discussion of the causes of differences between modeled and measured results as well as between results from different models, A sizable effort went into preparation of the database of the observations. This included a new climatology for ozone. The report should help in evaluating the results from various predictive models for assessing humankind perturbations of the stratosphere.

  5. Nuclear accident dosimetry studies at Los Alamos National Laboratory

    SciTech Connect

    Casson, W.H.; Buhl, T.E.; Upp, D.L.

    1995-12-01

    Two critical assemblies have been characterized at the Los Alamos Critical Experiments Facility (LACEF) for use in testing nuclear accident dosimeters and related devices. These device, Godiva IV and SHEBA II, have very different characteristics in both operation and emitted neutron energy spectra. The Godiva assembly is a bare metal fast burst device with a hard spectrum. This spectrum can be modified by use of several shields including steel, concrete, and plexiglas. The modified spectra vary in both average neutron energy and in the specific distribution of the neutron energies in the intermediate energy range. This makes for a very favorable test arrangement as the response ratios between different activation foils used in accident dosimeters are significantly altered such as the ratio between gold, copper, and sulfur elements. The SHEBA device is a solution assembly which has both a slow ramp and decay period and a much softer spectrum. The uncertainly introduced in the response of fast decay foils such as indium can therefore be evaluated into the test results. The neutron energy spectrum for each configuration was measured during low power operations with a multisphere system. These measurements were extended to high dose pulsed operation by use of TLDs moderated TLDs, and special activation techniques. The assemblies were used in the testing of several accident dosimetry devices in studies modeled after the Nuclear Accident Dosimetry Studies that were conducted at Oak Ridge National Laboratory for about 25 years using the Health Physics Research Reactor. It is our intention to conduct these studies approximately annually for the evaluation of the nuclear accident dosimeter systems currently in use within the DOE, alternative systems used internationally, and new dosimeter designs being developed or considered for field application. Participation in selected studies will be open to all participants.

  6. NOTE: Cell-phone interference with pocket dosimeters

    NASA Astrophysics Data System (ADS)

    Djajaputra, David; Nehru, Ramasamy; Bruch, Philip M.; Ayyangar, Komanduri M.; Raman, Natarajan V.; Enke, Charles A.

    2005-05-01

    Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag.

  7. Compton effect thermally activated depolarization dosimeter

    DOEpatents

    Moran, Paul R.

    1978-01-01

    A dosimetry technique for high-energy gamma radiation or X-radiation employs the Compton effect in conjunction with radiation-induced thermally activated depolarization phenomena. A dielectric material is disposed between two electrodes which are electrically short circuited to produce a dosimeter which is then exposed to the gamma or X radiation. The gamma or X-radiation impinging on the dosimeter interacts with the dielectric material directly or with the metal composing the electrode to produce Compton electrons which are emitted preferentially in the direction in which the radiation was traveling. A portion of these electrons becomes trapped in the dielectric material, consequently inducing a stable electrical polarization in the dielectric material. Subsequent heating of the exposed dosimeter to the point of onset of ionic conductivity with the electrodes still shorted through an ammeter causes the dielectric material to depolarize, and the depolarization signal so emitted can be measured and is proportional to the dose of radiation received by the dosimeter.

  8. Pen Ink as an Ultraviolet Dosimeter

    ERIC Educational Resources Information Center

    Downs, Nathan; Turner, Joanna; Parisi, Alfio; Spence, Jenny

    2008-01-01

    A technique for using highlighter ink as an ultraviolet dosimeter has been developed for use by secondary school students. The technique requires the students to measure the percentage of colour fading in ink drawn onto strips of paper that have been exposed to sunlight, which can be calibrated to measurements of the ultraviolet irradiance using…

  9. Investigating hydrogel dosimeter decomposition by chemical methods

    NASA Astrophysics Data System (ADS)

    Jordan, Kevin

    2015-01-01

    The chemical oxidative decomposition of leucocrystal violet micelle hydrogel dosimeters was investigated using the reaction of ferrous ions with hydrogen peroxide or sodium bicarbonate with hydrogen peroxide. The second reaction is more effective at dye decomposition in gelatin hydrogels. Additional chemical analysis is required to determine the decomposition products.

  10. Intercomparison of retrospective radon detectors.

    PubMed Central

    Field, R W; Steck, D J; Parkhurst, M A; Mahaffey, J A; Alavanja, M C

    1999-01-01

    We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha-emission of a (210)Pb-decay product, (210)Po. The detector's track density generation rate (tracks per square centimeter per hour) is proportional to the surface alpha-activity. In the absence of other strong sources of alpha-emission in the glass, the implanted surface alpha-activity should be proportional to the accumulated (210)Po, and hence to the cumulative radon gas exposure. The goals of the intercomparison were to a) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, b) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass-implanted polonium activities, and c) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted (210)Po activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type

  11. Panasonic dosimetry system performance testing and results at nuclear accident dose levels 500 rad to 10,000 rad

    SciTech Connect

    Klueber, M.R.

    1998-04-06

    Panasonic thermoluminescent dosimeters (TLDs) are used as the photon dose assessment part of the personal nuclear accident dosimeter (PNAD) and may be used for the same purpose with the fixed nuclear accident dosimeter (FNAD). To demonstrate compliance with 10CFR835.1304 (and, its predecessor, DOE Order 5480.11), several sets of dosimeters were irradiated to photon doses above the upper limit of the DOELAP testing standard, DOE/EH-0026 and DOE/EH-0027. The upper range of the test was 10,000 rads, using both low energy (70 keV) and high energy (662 keV and 1,332 keV) sources. The testing indicated that the Panasonic TLD system is capable of meeting the requirements of 10CFR835.1304 and DOE Order 5480.11.

  12. Clinical applications of 3-D dosimeters

    NASA Astrophysics Data System (ADS)

    Wuu, Cheng-Shie

    2015-01-01

    Both 3-D gels and radiochromic plastic dosimeters, in conjunction with dose image readout systems (MRI or optical-CT), have been employed to measure 3-D dose distributions in many clinical applications. The 3-D dose maps obtained from these systems can provide a useful tool for clinical dose verification for complex treatment techniques such as IMRT, SRS/SBRT, brachytherapy, and proton beam therapy. These complex treatments present high dose gradient regions in the boundaries between the target and surrounding critical organs. Dose accuracy in these areas can be critical, and may affect treatment outcome. In this review, applications of 3-D gels and PRESAGE dosimeter are reviewed and evaluated in terms of their performance in providing information on clinical dose verification as well as commissioning of various treatment modalities. Future interests and clinical needs on studies of 3-D dosimetry are also discussed.

  13. Exploring the dose response of radiochromic dosimeters

    NASA Astrophysics Data System (ADS)

    Skyt, P. S.; Wahlstedt, I.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2013-06-01

    The aim of this study was to explore the dose response of a newly developed radio-chromic hydrogel dosimeter based on leuco malachite green dye in a gelatine matrix. The original dosimeter composition was first investigated in terms of dose response and dose-rate dependence. In addition, the initiating compounds producing chlorine radicals were substituted with compounds producing fluorine radicals, oxygen-centered radicals, carbon-centered radicals and bromine radicals. Also the surfactant was substituted by other compounds of different molecular size and charge. The original composition gave a dose response of 3.5·10-3 Gy-1cm-1 at 6 Gy/min with a dose rate dependence giving a 27 % increase when decreasing the dose rate to 1 Gy/min. None of the substituted initiating components contributed to an increase in dose response while only one surfactant increased the dose response slightly.

  14. Radiological properties of normoxic polymer gel dosimeters

    SciTech Connect

    Venning, A.J.; Nitschke, K.N.; Keall, P.J.; Baldock, C.

    2005-04-01

    The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m{sup -3}) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.

  15. Water equivalence of polymer gel dosimeters

    NASA Astrophysics Data System (ADS)

    Sellakumar, P.; James Jebaseelan Samuel, E.; Supe, Sanjay S.

    2007-07-01

    To evaluate the water equivalence and radiation transport properties of polymer gel dosimeters over the wide range of photon and electron energies 14 different types of polymer gels were considered. Their water equivalence was evaluated in terms of effective atomic number ( Zeff), electron density ( ρe), photon mass attenuation coefficient ( μ/ρ), photon mass energy absorption coefficient ( μen/ρ) and total stopping power (S/ρ)tot of electrons using the XCOM and the ESTAR database. The study showed that the effective atomic number of polymer gels were very close ( <1%) to that of water except PAGAT, MAGAT and NIPAM which had the variation of 3%, 2% and 3%, respectively. The value of μ/ρ and μen/ρ for all polymer gels were in close agreement ( <1%) with that of water beyond 80 keV. The value of (S/ρ)tot of electrons in polymer gel dosimeters were within 1% agreement with that of water. From the study we conclude that at lower energy ( <80 keV) the polymer gel dosimeters cannot be considered water equivalent and study has to be carried out before using the polymer gel for clinical application.

  16. Post-Irradiation Study of the Alanine Dosimeter

    PubMed Central

    Desrosiers, Marc F.

    2014-01-01

    Post-irradiation stability of high-dose dosimeters has traditionally been an important measurement influence quantity. Though the exceptional stability of the alanine dosimeter response with time has rendered this factor a non-issue for routine work, the archival quality of the alanine dosimeter has not been characterized. Here the alanine pellet dosimeter response is measured up to seven years post-irradiation for a range of absorbed doses. This long-term study is accompanied by an examination of the environmental influence quantities (e.g., ambient light) on the relatively short-term (3–4 month) stability of both pellet and film commercial dosimeters. Both dosimeter types demonstrated exceptional stability in the short term and proved to be relatively insensitive to common influence quantities. The long-term data revealed a complex dose-dependent response trend. PMID:26601033

  17. Methacholine bronchial challenge using a dosimeter with controlled tidal breathing.

    PubMed Central

    Nieminen, M M; Lahdensuo, A; Kellomaeki, L; Karvonen, J; Muittari, A

    1988-01-01

    A new inhalation synchronised dosimeter triggered by low inspiratory flow rates has been assessed. The methacholine challenge test using dosimeter nebulisation with controlled tidal breathing was compared with continuous nebulisation using De Vilbiss No 40 nebulisers with deep inhalations in 11 asthmatic subjects. Within subject PD20 FEV1 values were lower with the dosimeter method than with the continuous nebulisation method (geometric means 158 and 588 micrograms). The repeatability of the dosimeter method with controlled tidal breathing was studied in 11 asthmatic subjects, and the 95% range for a single measurement was +/- 0.72 doubling doses of methacholine. The dosimeter method has greater efficacy because aerosol is delivered during the first part of an inhalation, minimising loss of aerosol outside the respiratory tract. The dosimeter technique combined with controlled tidal breathing appears to be a useful method for carrying out standardised non-specific bronchoprovocation tests. Images PMID:3065974

  18. EURADOS intercomparison on emergency radiobioassay.

    PubMed

    Li, Chunsheng; Battisti, Paolo; Berard, Philippe; Cazoulat, Alain; Cuellar, Antonio; Cruz-Suarez, Rodolfo; Dai, Xiongxin; Giardina, Isabella; Hammond, Derek; Hernandez, Carolina; Kiser, Stephen; Ko, Raymond; Kramer-Tremblay, Sheila; Lecompte, Yannick; Navarro, Eva; Navas, Cristina; Sadi, Baki; Sierra, Inmaculada; Verrezen, Freddy; Lopez, Maria A

    2015-12-01

    Nine laboratories participated in an intercomparison exercise organised by the European Radiation Dosimetry Group (EURADOS) for emergency radiobioassay involving four high-risk radionuclides ((239)Pu, (241)Am, (90)Sr and (226)Ra). Diverse methods of analysis were used by the participating laboratories for the in vitro determination of each of the four radionuclides in urine samples. Almost all the methods used are sensitive enough to meet the requirements for emergency radiobioassay derived for this project in reference to the Clinical Decision Guide introduced by the NCRP. Results from most of the methods meet the requirements of ISO 28218 on accuracy in terms of relative bias and relative precision. However, some technical gaps have been identified. For example, some laboratories do not have the ability to assay samples containing (226)Ra, and sample turnaround time would be expected to be much shorter than that reported by many laboratories, as timely results for internal contamination and early decisions on medical intervention are highly desired. Participating laboratories are expected to learn from each other on the methods used to improve the interoperability among these laboratories.

  19. Intercomparison of luminescence detectors for space radiation dosimetry within Proton-ICCHIBAN experiments

    NASA Astrophysics Data System (ADS)

    Uchihori, Yukio; Ploc, Ondrej; Yasuda, Nakahiro; Berger, Thomas; Hajek, Michael; Kodaira, Satoshi; Benton, Eric; Ambrozova, Iva; Kitamura, Hisashi

    2012-07-01

    Luminescence detectors for space radiation dosimetry are frequently used to estimate personal and environmental doses in the International Space Station and other space vehicles. Detector responses for cosmic rays and their secondaries were investigated for a long time and it is well-known that luminescence detectors have dependencies of response on LET (Linear Energy Transfer). Some of luminescence detectors show over-response to gamma rays (used for routine calibration) and others have similar responses to gamma rays. But, because of lack of sufficient and reliable calibration data in the low LET region (about 1 keV/μm), it is the responses of these detectors at LET is poorly known. Protons make up the dominant portion of the fluence from space radiation, so the LET region corresponding to energetic protons must be characterized very well. For that purpose, calibration and intercomparison experiments were performed using relatively low energy (30 to 80 MeV) proton beams at the National Institute of Radiological Sciences, Chiba, Japan. In this paper, the results of these intercomparison experiments, including high energy protons and light ions, are reported and illustrate the response of luminescence detectors in the low LET region. This research will help improve our understanding of space dosimeters and reliable dose measurement for astronauts and cosmonauts in low earth orbit.

  20. Comparison of the fiber optic dosimeter and semiconductor dosimeter for use in diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Yoo, W. J.; Shin, S. H.; Sim, H. I.; Hong, S.; Kim, S. G.; Jang, J. S.; Kim, J. S.; Jeon, H. S.; Kwon, G. W.; Jang, K. W.; Cho, S.; Lee, B.

    2014-05-01

    A fiber-optic dosimeter (FOD) was fabricated using a plstic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure entrance surface dose (ESD) in diagnostic radiology. Under changing tube current and irradition time of the digital radiography (DR) system, we measured the scintillating light and the ESD simultaneously. As experiemtnal results, the total counts of the FOD were changed in a manner similar to the ESDs of the semiconductor dosimeter (SCD). In conclusion, we demonstrated that the proposed FOD minimally affected the diagnostic information of DR image while the SCD caused serious image artifacts.

  1. Passive electronic dosimeters based on direct ion storage

    SciTech Connect

    Kahilainen, J.

    1995-12-31

    Using non-volatile semiconductor memories as dosimeters in radiation protection is made possible by the application of the so-called DIS (Direct Ion Storage) method, where the charge collected from a small volume of gas is directly stored in a non-volatile memory cell. This allows the construction of small and simple electronic passive dosimeters with features not available in conventional passive Film or TLD dosimeters. The basic design principles and properties of DIS dosimeters are presented and the application potential for the measurement of various categories of ionizing radiation is discussed.

  2. GAMMA AND X-RAY DOSIMETER AND DOSIMETRIC METHOD

    DOEpatents

    Taplin, G.V.; Douglas, C.H.; Sigoloff, S.C.

    1958-08-19

    An improvement in colorimetric gamma and x-ray dosimeter systems and a self-contained. hand carried dostmeter of the afore-mentioned type ts described. A novel point of the invention ltes in the addition of specific quantities of certain normalizing agents to the two phase chlorinated hydro-carbon-aqueous dyc colortmetric dosimeter to eliminate the after reaction and thereby extend the utility of such systein. The structure of the two phase colorimetric dosimeter tubes and the carrying case for the tubes of the portable dosimeter are unique features.

  3. INTERCOMPARISON OF OPTICAL REMOTE SENSING SYSTEMS FOR ROADSIDE MEASUREMENTS

    EPA Science Inventory

    The presentation describes results of an intercomparison of three optical remote sensing systems for measurements of nitric oxide emitted from passenger cars and light-duty trucks. The intercomparison included a standards comparison to establish comparability of standards, follo...

  4. Desert Dust Satellite Retrieval Intercomparison

    NASA Technical Reports Server (NTRS)

    Carboni, E.; Thomas, G. E.; Sayer, A. M.; Siddans, R.; Poulsen, C. A.; Grainger, R. G.; Ahn, C.; Antoine, D.; Bevan, S.; Braak, R.; Brindley, H.; DeSouza-Mchado, S.; Deuze, J. L.; Diner, D.; Ducos, F.; Grey, W.; Hsu, C.; Kalashnikova, O. V.; Kahn, R.; North, P. R. J.; Salustro, C.; Smith, A.; Tanre, D.; Torres, O.; Veihelmann, B.

    2012-01-01

    This work provides a comparison of satellite retrievals of Saharan desert dust aerosol optical depth (AOD) during a strong dust event through March 2006. In this event, a large dust plume was transported over desert, vegetated, and ocean surfaces. The aim is to identify and understand the differences between current algorithms, and hence improve future retrieval algorithms. The satellite instruments considered are AATSR, AIRS, MERIS, MISR, MODIS, OMI, POLDER, and SEVIRI. An interesting aspect is that the different algorithms make use of different instrument characteristics to obtain retrievals over bright surfaces. These include multi-angle approaches (MISR, AATSR), polarisation measurements (POLDER), single-view approaches using solar wavelengths (OMI, MODIS), and the thermal infrared spectral region (SEVIRI, AIRS). Differences between instruments, together with the comparison of different retrieval algorithms applied to measurements from the same instrument, provide a unique insight into the performance and characteristics of the various techniques employed. As well as the intercomparison between different satellite products, the AODs have also been compared to co-located AERONET data. Despite the fact that the agreement between satellite and AERONET AODs is reasonably good for all of the datasets, there are significant differences between them when compared to each other, especially over land. These differences are partially due to differences in the algorithms, such as as20 sumptions about aerosol model and surface properties. However, in this comparison of spatially and temporally averaged data, at least as significant as these differences are sampling issues related to the actual footprint of each instrument on the heterogeneous aerosol field, cloud identification and the quality control flags of each dataset.

  5. A sensitive neutron dosimeter using superheated liquid.

    PubMed

    Das, M; Roy, B; Chatterjee, B K; Roy, S C

    2000-01-01

    The present work relates to a sensitive neutron dosimeter, a device for monitoring neutron dose in some accelerator and reactor sites. This device is capable of measuring a neutron dose as small as 0.1 microSv using superheated liquid as a sensitive liquid. The nucleation was measured by the volumetric method developed in our laboratory. The dose response of superheated drops of four liquids having boiling points of 8.92, -29.79, -40.75 and -45.6 degrees C, irradiated by a 3 Ci Am-Be neutron source has also been presented in this article.

  6. Quantitative evaluation of polymer gel dosimeters by broadband ultrasound attenuation

    NASA Astrophysics Data System (ADS)

    Khoei, S.; Trapp, J. V.; Langton, C. M.

    2013-06-01

    Ultrasound has been examined previously as an alternative readout method for irradiated polymer gel dosimeters, with authors reporting varying dose response to ultrasound transmission measurements. In this current work we extend previous work to measure the broadband ultrasound attenuation (BUA) response of irradiated PAGAT gel dosimeters, using a novel ultrasound computed tomography system.

  7. Preliminary investigation and application of a novel deformable PRESAGE® dosimeter

    PubMed Central

    Juang, T; Newton, J; Das, S; Adamovics, J; Oldham, M

    2013-01-01

    Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter irradiated with an MLC pencilbeam checkerboard pattern under lateral compression up to 27% to a non-deformed control dosimeter irradiated with the same pattern verified dose tracking under deformation. CTs of the experimental dosimeter prior to and during compression were exported into VelocityAI and used to map an Eclipse dose distribution calculated on the compressed dosimeter to its original shape. A comparison between the VelocityAI dose distribution and the distribution from the dosimeter showed field displacements up to 7.3 mm and up to a 175% difference in field dimensions. These results highlight the need for validating deformable dose mapping algorithms to ensure patient safety and quality of care. PMID:24454522

  8. Evaluation of a Colorimetric Personal Dosimeter for Nitrogen Oxide.

    ERIC Educational Resources Information Center

    Diamond, Philip

    A personal colorimetric dosimeter for nitrogen dioxide was developed. Tests were performed to determine the response of these strips to various concentrations of NO2. The dosimeter strips were satisfactory for approximate determinations of total exposure (concentration + time) of nitrogen dioxide. The total exposure was calculated in terms of time…

  9. Indoor and Outdoor Spectroradiometer Intercomparison for Spectral Irradiance Measurement

    SciTech Connect

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, R.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-05-01

    This report details the global spectral irradiance intercomparison using spectroradiometers that was organized by the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. The intercomparison was performed both indoors and outdoors on September 17, 2013. Five laboratories participated in the intercomparison using 10 spectroradiometers, and a coordinated measurement setup and a common platform were employed to compare spectral irradiances under both indoor and outdoor conditions. The intercomparison aimed to understand the performance of the different spectroradiometers and to share knowledge in making spectral irradiance measurements. This intercomparison was the first of its kind in the United States.

  10. The development of a passive dosimeter for airborne aniline vapors.

    PubMed

    Campbell, J E; Konzen, R B

    1980-03-01

    A passive diffusion dosimeter has been suggested as an economical and accurate means of sampling airborne concentrations of gases and vapors in the working environment. The dosimeter utilizes molecular diffusion through a tube of known geometry to obtain a quantitative determination of airborne concentrations of the contaminant of interest. A passive sampling dosimeter was designed to measure concentrations of aniline vapor in air. Diffusion tubes of 1.5, 3.0, and 4.5 cm lengths were tested under controlled conditions of relative humidity, air temperature, and vapor concentrations. The results indicate that the use of a passive diffusion dosimeter for determining time-weighted average concentrations of aniline is feasible. It was shown that a 1 cm diameter 3.0 cm length diffusion tube gave the most consistent results. It is suggested that further investigations be conducted in the development of passive diffusion dosimeters for other gaseous contaminants.

  11. Laser readable thermoluminescent radiation dosimeters and methods for producing thereof

    DOEpatents

    Braunlich, Peter F.; Tetzlaff, Wolfgang

    1989-01-01

    Thin layer thermoluminescent radiation dosimeters for use in laser readable dosimetry systems, and methods of fabricating such thin layer dosimeters. The thin layer thermoluminescent radiation dosimeters include a thin substrate made from glass or other inorganic materials capable of withstanding high temperatures and high heating rates. A thin layer of a thermoluminescent phoshphor material is heat bonded to the substrate using an inorganic binder such as glass. The dosimeters can be mounted in frames and cases for ease in handling. Methods of the invention include mixing a suitable phosphor composition and binder, both being in particulate or granular form. The mixture is then deposited onto a substrate such as by using mask printing techniques. The dosimeters are thereafter heated to fuse and bond the binder and phosphor to the substrate.

  12. Laser readable thermoluminescent radiation dosimeters and methods for producing thereof

    DOEpatents

    Braunlich, P.F.; Tetzlaff, W.

    1989-04-25

    Thin layer thermoluminescent radiation dosimeters for use in laser readable dosimetry systems, and methods of fabricating such thin layer dosimeters are disclosed. The thin layer thermoluminescent radiation dosimeters include a thin substrate made from glass or other inorganic materials capable of withstanding high temperatures and high heating rates. A thin layer of a thermoluminescent phosphor material is heat bonded to the substrate using an inorganic binder such as glass. The dosimeters can be mounted in frames and cases for ease in handling. Methods of the invention include mixing a suitable phosphor composition and binder, both being in particulate or granular form. The mixture is then deposited onto a substrate such as by using mask printing techniques. The dosimeters are thereafter heated to fuse and bond the binder and phosphor to the substrate. 34 figs.

  13. Radiation accidents

    SciTech Connect

    Saenger, E.L.

    1986-09-01

    It is essential that emergency physicians understand ways to manage patients contaminated by radioactive materials and/or exposed to external radiation sources. Contamination accidents require careful surveys to identify the metabolic pathway of the radionuclides to guide prognosis and treatment. The level of treatment required will depend on careful surveys and meticulous decontamination. There is no specific therapy for the acute radiation syndrome. Prophylactic antibodies are desirable. For severely exposed patients treatment is similar to the supportive care given to patients undergoing organ transplantation. For high-dose extremity injury, no methods have been developed to reverse the fibrosing endarteritis that eventually leads to tissue death so frequently found with this type of injury. Although the Three Mile Island episode of March 1979 created tremendous public concern, there were no radiation injuries. The contamination outside the reactor building and the release of radioiodine were negligible. The accidental fuel element meltdown at Chernobyl, USSR, resulted in many cases of acute radiation syndrome. More than 100,000 people were exposed to high levels of radioactive fallout. The general principles outlined here are applicable to accidents of that degree of severity.

  14. Radiation accidents.

    PubMed

    Saenger, E L

    1986-09-01

    It is essential that emergency physicians understand ways to manage patients contaminated by radioactive materials and/or exposed to external radiation sources. Contamination accidents require careful surveys to identify the metabolic pathway of the radionuclides to guide prognosis and treatment. The level of treatment required will depend on careful surveys and meticulous decontamination. There is no specific therapy for the acute radiation syndrome. Prophylactic antibodies are desirable. For severely exposed patients treatment is similar to the supportive care given to patients undergoing organ transplantation. For high-dose extremity injury, no methods have been developed to reverse the fibrosing endarteritis that eventually leads to tissue death so frequently found with this type of injury. Although the Three Mile Island episode of March 1979 created tremendous public concern, there were no radiation injuries. The contamination outside the reactor building and the release of radioiodine were negligible. The accidental fuel element meltdown at Chernobyl, USSR, resulted in many cases of acute radiation syndrome. More than 100,000 people were exposed to high levels of radioactive fallout. The general principles outlined here are applicable to accidents of that degree of severity. PMID:3526994

  15. A scintillating fiber dosimeter for radiotherapy

    NASA Astrophysics Data System (ADS)

    Bartesaghi, G.; Conti, V.; Bolognini, D.; Grigioni, S.; Mascagna, V.; Prest, M.; Scazzi, S.; Mozzanica, A.; Cappelletti, P.; Frigerio, M.; Gelosa, S.; Monti, A.; Ostinelli, A.; Giannini, G.; Vallazza, E.

    2007-10-01

    Radiotherapy, together with chemotherapy and surgery, is one of the main methods applied in the fight against cancer; in order to increase the chances of a successful radiotherapy treatment the dose delivery to the tumor and the surrounding normal tissues has to be computed with high accuracy. Traditional dosimeters are accurate but single channel (ionization chambers and diodes) or non real-time (radiographic films) devices. At present there is no device water equivalent that can perform real-time and bidimensional measurements of a dose distribution. This article describes the development of a real-time dosimeter based on scintillating fibers for photon and electron beams; the fibers are made of polystyrene, that is water equivalent and thus tissue equivalent, allowing a direct dose calculation. Three prototypes (single and multichannel) have been assembled, consisting in small scintillators coupled to white fibers that carry the light to photomultiplier tubes. In this article the prototypes and the readout electronics are described, together with the results of the measurements with electron and photon beams with energy up to 20 MeV (produced by linear accelerators Varian Clinac 1800 and 2100CD).

  16. A dosimetry intercomparison phantom for intraoperative radiotherapy.

    PubMed

    Armoogum, Kris; Watson, Colin

    2008-01-01

    Intraoperative radiotherapy (IORT) using very low kV x-rays is a promising new treatment modality and has proven to be effective for managing breast and neurological tumours. We have treated in excess of 75 patients using four Zeiss Intrabeam x-ray sources (XRS). To date there has been no published data of any dosimetric intercomparison of this type of x-ray source used at other cancer centres worldwide. This paper describes the design of a simple dosimetry intercomparison phantom for use with these very low kV x-ray sources. A prototype polymethyl methacrylate (PMMA) phantom has been manufactured, the dimensions of which were determined by the dimensions of the XRS, the beam energy and the attenuating properties of PMMA. The phantom is used in conjunction with Gafchromic XR Type-R film (GC-XRR) and its purpose is to measure the absorbed dose at a fixed distance from the effective point source at the tip of the XRS. The utility of this phantom is further enhanced through the use of an interlock, which eliminates the need to use the mobile gantry. We have used this phantom to conduct a qualitative dosimetric intercomparison of four Zeiss Intrabeam x-ray sources with positive results. This phantom is low cost, easy to manufacture, simple to use and could be adopted as a standard method of dosimetric intercomparison for Intrabeam x-ray sources as this mode of IORT becomes more widespread. PMID:18705612

  17. SPARC Reanalysis Intercomparison Project (S-RIP)

    NASA Astrophysics Data System (ADS)

    Fujiwara, M.; Long, C. S.

    2014-12-01

    The middle atmosphere and climate community use reanalyses widely to understand atmospheric processes and variability in the middle atmosphere, to validate climate models, and, potentially, for trend analysis. Yet different reanalyses give different results for the same diagnostic. There is thus a need for a coordinated reanalysis intercomparison project that shall start a comprehensive activity to compare all appropriate reanalysis data sets for key diagnostics to help understand the causes of differences and to use the results to provide guidance on appropriate usage of various reanalysis products in scientific studies. In addition, the reanalysis community will benefit from coordinated user feedback, which can lead to improvements in the next generation of reanalysis products. The Stratosphere-troposphere Processes And their Role in Climate (SPARC) Reanalysis Intercomparison Project (S-RIP) is a SPARC activity that was proposed in 2012 and approved in 2014. The goals of S-RIP are: (1) to create a communication platform between the SPARC community and the reanalysis centers; (2) to understand current reanalysis products and to contribute to future reanalysis improvements in the middle atmosphere region; and (3) to write up the results of the reanalysis intercomparison in peer reviewed papers and a SPARC report. The project duration is from 2013 to 2018. In the presentation, an overview of the project is made and some early intercomparison results are discussed.

  18. A Method of Determining Accuracy and Precision for Dosimeter Systems Using Accreditation Data

    SciTech Connect

    Rick Cummings and John Flood

    2010-12-01

    A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively.

  19. A method of determining accuracy and precision for dosimeter systems using accreditation data.

    PubMed

    Cummings, Frederick; Flood, John R

    2010-12-01

    A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively. PMID:21068596

  20. Limitations of using dosimeters in impulse noise environments.

    PubMed

    Kardous, Chucri A; Willson, Robert D

    2004-07-01

    The National Institute for Occupational Safety and Health (NIOSH) investigated the capabilities of noise dosimeters to measure personal exposure to impulse noise. The two leading types of commercially available dosimeters were evaluated in terms of their ability to measure and integrate impulses generated from gunfire during live-fire exercises at a law enforcement indoor firing range. Sound measurements were conducted throughout the firing range using dosimeters, sound level meters, and a measurement configuration that consisted of a quarter-inch microphone and a digital audiotape recorder to capture the impulse waveforms. Personal dosimetry was conducted on eight shooters, an observer, and the range master. Peak levels from gunfire reached 163 decibels (dB), exceeding the nominal input limit of the dosimeters. The dosimeters "clipped" the impulses by acting as if the gunfire had a maximum level of 146 dB. In other cases, however, peak levels (e.g., 108 dB) were below the dosimeter input limits, but the dosimeters still showed a peak level of 146 dB. Although NIOSH recommends that sound levels from 80 to 140 dB (A-weighted) be integrated in the calculation of dose and the time-weighted average, our present data suggest this criterion may be inadequate. These results showed that some instruments are incapable of providing accurate measures of impulse sounds because of their electroacoustic limitations.

  1. Light scattering in optical CT scanning of Presage dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Adamovics, J.; Cheeseborough, J. C.; Chao, K. S.; Wuu, C. S.

    2010-11-01

    The intensity of the scattered light from the Presage dosimeters was measured using a Thorlabs PM100D optical power meter (Thorlabs Inc, Newton, NJ) with an optical sensor of 1 mm diameter sensitive area. Five Presage dosimeters were made as cylinders of 15.2 cm, 10 cm, 4 cm diameters and irradiated with 6 MV photons using a Varian Clinac 2100EX. Each dosimeter was put into the scanning tank of an OCTOPUS" optical CT scanner (MGS Research Inc, Madison, CT) filled with a refractive index matching liquid. A laser diode was positioned at one side of the water tank to generate a stationary laser beam of 0.8 mm width. On the other side of the tank, an in-house manufactured positioning system was used to move the optical sensor in the direction perpendicular to the outgoing laser beam from the dosimeters at an increment of 1 mm. The amount of scattered photons was found to be more than 1% of the primary light signal within 2 mm from the laser beam but decreases sharply with increasing off-axis distance. The intensity of the scattered light increases with increasing light attenuations and/or absorptions in the dosimeters. The scattered light at the same off-axis distance was weaker for dosimeters of larger diameters and for larger detector-to-dosimeter distances. Methods for minimizing the effect of the light scattering in different types of optical CT scanners are discussed.

  2. Radiation Measured during ISS-Expedition 13 with Different Dosimeters

    NASA Technical Reports Server (NTRS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Lee, K.; George, T.

    2008-01-01

    Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

  3. SU-E-T-265: Presage Thin Sheet Dosimeter Characterization

    SciTech Connect

    Dumas, M; Rakowski, J

    2014-06-01

    Purpose: To quantify the sensitivity and stability of the Presage dosimeter in sheet form for different concentrations of chemicals and for a diverse range of clinical photon energies. Methods: Presage polymer dosimeters are formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green reporting dye, and bromoform radical initiator in 1mm thick sheets. The chemicals are well mixed together, cast in an aluminum mold, and left to cure at 60 psi for a minimum of 2 days. Dosimeter response will be characterized at multiple energies including Co-60, 6 MV, 15 MV, 50 kVp, and 250 kVp. The dosimeters are read by an Epson 10000 XL scanner at 800 dpi, 2{sup 16} bit depth. Red component images are analyzed with ImageJ. Results: Analysis of optical density verse dose for Co-60 energies indicates that the bromoform containing Presage was able to quantify dose from 0 to 300 Gy, with saturation beyond 300 Gy. Initial results show two regions of linear response, 0–100 Gy and 150–300 Gy. The 150–300 Gy region has a sensitivity of 0.0024 net OD/Gy. Further results on other energies are still in progress. Conclusions: This work shows the potential for use of thin sheets of Presage dosimeter as a dosimeter capable of being analyzed with a flatbed scanner.

  4. p-MOSFET total dose dosimeter

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  5. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, T.

    1987-07-14

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

  6. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, Tuan

    1987-01-01

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique.

  7. A new dosimeter formulation for deformable 3D dose verification

    NASA Astrophysics Data System (ADS)

    Høye, E. M.; Skyt, P. S.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2015-01-01

    We present the characteristics of a new silicone-based radiochromic dosimeter containing the leuco-malachite green (LMG) dye. The dose response as well as the dose-rate and photon-energy dependence of the dosimeter were characterized. To optimise the dose response, different concentrations of the chemical components were investigated. The dose response was found to decrease exponentially as a function of time after irradiation. A cylindrical dosimeter was produced and irradiated with a volumetric modulated arc therapy plan; the standard deviation between measured and calculated dose was 5% of the total dose.

  8. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    PubMed

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together. PMID:22389154

  9. Investigation of thermoluminescence properties of mobile phone screen displays as dosimeters for accidental dosimetry

    NASA Astrophysics Data System (ADS)

    Mrozik, Anna; Marczewska, B.; Bilski, P.; Kłosowski, M.

    2014-11-01

    The rapid assessment of the radiation dose after unexpected exposure is a task of accidental dosimetry. In case of a radiological accident glasses originating from mobile phone screens, placed usually near the human body, could be used as emergency thermoluminescent (TL) personal dosimeters. The time between irradiation and TL readout is crucial and therefore preparation of the mobile phone screens and their readout conditions should be optimized. The influence of the samples etching, bleaching and selection of the optical filters based on measurement of the emission spectrum of irradiated glass samples during heating for different types of mobile phones were the subjects of our investigation. Obtained results showed that glasses extracted from different brands of mobile phones have different dosimetric properties but all of them give a luminescent signal which can be used to calculate the dose.

  10. A miniature MOSFET radiation dosimeter probe.

    PubMed

    Gladstone, D J; Lu, X Q; Humm, J L; Bowman, H F; Chin, L M

    1994-11-01

    Prototype miniature dosimeter probes have been designed, built, and characterized employing a small, radiation sensitive metal oxide semiconductor field effect transistor (MOSFET) chip to measure, in vivo, the total accumulated dose and dose rate as a function of time after internal administration of long range beta particle radiolabeled antibodies and in external high energy photon and electron beams. The MOSFET detector is mounted on a long narrow alumina substrate to facilitate electrical connection. The MOSFET, alumina substrate, and lead wires are inserted into a 16 gauge flexineedle, which, in turn, may be inserted into tissue. The radiation dosimeter probe has overall dimensions of 1.6 mm diam and 3.5 cm length. The MOSFET probe signals are read, stored, and analyzed using an automated data collection and analysis system. Initially, we have characterized the probe's response to long range beta particle emission from 90Y sources in solution and to high energy photon and electron beams from linear accelerators. Since the prototype has a finite substrate thickness, the angular dependence has been studied using beta particle emission from a 90Sr source. Temperature dependence and signal drift have been characterized and may be corrected for. Measurements made in spherical volumes containing 90Y with diameters less than the maximum electron range, to simulate anticipated geometries in animal models, agree well with Berger point kernel and EGS4 Monte Carlo calculations. The results from the prototype probes lead to design requirements for detection of shorter range beta particles used in radioimmunotherapy and lower photon energies used in brachytherapy. PMID:7891632

  11. Airborne intercomparisons of carbon monoxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, James M., Jr.; Gregory, Gerald L.; Mcdougal, David S.; Sachse, Glen W.; Hill, Gerald F.; Condon, Estelle P.

    1987-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of carbon monoxide (CO) are discussed. The intercomparison was conducted as part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and included a laser differential absorption method and two grab sample/gas chromatograph methods. Measurements were obtained during approximately 90 flight hours, during which the CO mixing ratios ranged from about 60 to 140 ppbv. The level of agreement observed for the ensemble of measurements was well within the overall accuracy stated for each instrument. The correlation observed between the measurements from the respective pairs of instruments ranged from 0.85 to 0.98, with no evidence for the presence of either a constant or proportional bias between any of the instruments.

  12. European whole body counter measurement intercomparison.

    PubMed

    Thieme, M; Hunt, E L; König, K; Schmitt-Hannig, A; Gödde, R

    1998-04-01

    In order to test the common quality standards for the performance of measurements of internal radioactivity, the European Commission funded a European intercomparison of whole body counters, which was organized and carried out by the Institut fuer Strahlenhygiene (part of the German Bundesamt fuer Strahlenschutz). Forty-four whole body counting facilities from forty-two institutions in nineteen countries (the fifteen member states of the European Union plus Hungary, the Czech Republic, Switzerland and Norway) took part in this intercomparison, which made it the most comprehensive ever carried out in Europe. For the study, the 70 kg tissue equivalent St Petersburg phantom was used with rods containing 40K, 57Co, 60Co, and 137Cs. The overall results of the whole body counter study were rather good.

  13. Method and apparatus for reading free falling dosimeter punchcodes

    DOEpatents

    Langsted, J.M.

    1992-12-22

    A punchcode reader is provided for reading data encoded in a punchcode hole array on a dosimeter. The dosimeter falls through a passage in the reader containing photosensor detectors disposed along the passage which provide output signals to a microprocessor. The signals are processed to determine the orientation of the dosimeter in the reader, the location and state of punchcode holes in a two row array thereby decoding the encoded data. Multiple rate of fall calculations are made, and if appropriate matching of the punchcode array is not obtained in three tries, an error signal is output to the operator. The punchcode reader also provides for storage of data from multiple dosimeters passed through the reader, and for the output of decoded data to an external display or a computer for further processing. 8 figs.

  14. Method and apparatus for reading free falling dosimeter punchcodes

    DOEpatents

    Langsted, James M.

    1992-12-22

    A punchcode reader is provided for reading data encoded in a punchcode hole array on a dosimeter. The dosimeter falls through a passage in the reader containing photosensor detectors disposed along the passage which provide output signals to a microprocessor. The signals are processed to determine the orientation of the dosimeter in the reader, the location and state of punchcode holes in a two row array thereby decoding the encoded data. Multiple rate of fall calculations are made, and if appropriate matching of the punchcode array is not obtained in three tries, an error signal is outputted to the operator. The punchcode reader also provides for storage of data from multiple dosimeters passed through the reader, and for the output of decoded data to an external display or a computer for further processing.

  15. [Fabrication of annealing equipment for optically stimulated luminescence (OSL) dosimeter].

    PubMed

    Nakagawa, Kohei; Hayashi, Hiroaki; Okino, Hiroki; Takegami, Kazuki; Okazaki, Tohru; Kobayashi, Ikuo

    2014-10-01

    The optically stimulated luminescence (OSL) dosimeter is a useful detector for measuring absorbed doses of X-rays. A small-type OSL dosimeter, "nanoDot", has recently been developed by Landauer, Inc., who also manufacture "microStar" reading equipment. However, additional annealing equipment is needed if the nanoDot OSL dosimeter is used repeatedly. The aim of this study was to fabricate suitable annealing equipment using commonly available products. Our device positions four fluorescent light tubes in a close configuration. The heat from the fluorescent light tubes is dissipated using fans. Experiments using diagnostic X-ray equipment were carried out to evaluate the capability of our annealing equipment. The results indicated that our equipment can fully anneal the nanoDot OSL dosimeter with annealing times of approximately 20 hours. PMID:25327423

  16. Fast neutron detection with Al 2O 3 thermoluminescence dosimeter

    NASA Astrophysics Data System (ADS)

    Ranogajec-Komor, Maria; Osvay, Margit; Dvornik, Igor; Biró, Tamàs

    1983-07-01

    The technique of thermoluminescent (TL) dosimeter activation can be used to detect any radiation making TL dosimeters radioactive. In the experiment discussed in this paper Al2O3:Mg, Y TL dosimeters were irradiated by cyclotron neutrons with 5±1 MeV mean energy and by accompanying gamma rays. The gamma and the fast neutron component can be separately measured by the same dosimeter. Because of low neutron sensitivity of Al2O3 the gamma dose can be determined by the first TL reading while the 27Al(n, α)24 Na reaction provides the possibility of fast neutron detection by the subsequent reading of thermoluminescence induced in the TL material by the decay of 24Na.

  17. Antioxidant effect of green tea on polymer gel dosimeter

    NASA Astrophysics Data System (ADS)

    Samuel, E. J. J.; Sathiyaraj, P.; Deena, T.; Kumar, D. S.

    2015-01-01

    Extract from Green Tea (GTE) acts as an antioxidant in acrylamide based polymer gel dosimeter. In this work, PAGAT gel was used for investigation of antioxidant effect of GTE.PAGAT was called PAGTEG (Polyacrylamide green tea extract gel dosimeter) after adding GTE. Free radicals in water cause pre polymerization of polymer gel before irradiation. Polyphenols from GTE are highly effective to absorb the free radicals in water. THPC is used as an antioxidant in polymer gel dosimeter but here we were replaced it by GTE and investigated its effect by spectrophotometer. GTE added PAGAT samples response was lower compared to THPC added sample. To increase the sensitivity of the PAGTEG, sugar was added. This study confirmed that THPC was a good antioxidant for polymer gel dosimeter. However, GTE also can be used as an antioxidant in polymer gel if use less quantity (GTE) and add sugar as sensitivity enhancer.

  18. Inter-comparison of subglacial hydrological models

    NASA Astrophysics Data System (ADS)

    de Fleurian, Basile; Werder, Mauro

    2016-04-01

    The recent emergence of a number of subglacial hydrological models allows us to obtain theoretical insights on basal processes; for instance on the coupling between water pressure and the sliding of glaciers. In ice-flow models, it is relatively clear what the simulated physics ought to be. Conversely, the physical processes incorporated into subglacial hydrology models are diverse as it is yet unclear which ones are of relevance for a particular setting. An inter-comparison of hydrology models will therefore need a somewhat different approach to the one used in the many ice-flow model inter-comparisons (EISMINT, ISMIP, etc.). Here, we present a set of experiments that will allow the comparison of the behavior of different hydrology models. The design of the benchmark aims at allowing the participation of a wide range of models based on different physical approaches. We aim at evaluating the models with a focus on the effective pressure which has the most impact on the dynamics of glaciers. The aim of this inter-comparison is to provide modellers with the necessary data to make an informed decision on which subglacial hydrology model to use for a particular study.

  19. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    DOEpatents

    Vo-Dinh, Tuan

    1995-01-01

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devises, in probe array devices.

  20. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    DOEpatents

    Vo-Dinh, T.

    1995-03-21

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devices, in probe array devices. 10 figures.

  1. Methods and means of checking thermoluminescent and radiophotoluminescent dosimeters

    SciTech Connect

    Fominykh, V.I.; Oborin, A.V.; Sebekin, A.P.; Uryaev, I.A.

    1987-06-01

    The authors discuss methods of checking thermoluminescent and radiophotoluminescent dosimeters which are used often in monitoring radiation safety in various areas including nuclear power stations. When the dosimeters are checked in the fields of standard beta-ray sources, it is recommended that the standard absorbed-dose or equivalent-dose measures for beta radiation should be sources of /sup 90/Sr + /sup 90/Y, /sup 204/Tl, and /sup 147/Pm. Various safety guidelines are discussed.

  2. Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison

    SciTech Connect

    Harrison, K. M.; Ebert, M. A.; Kron, T.; Howlett, S. J.; Cornes, D.; Hamilton, C. S.; Denham, J. W.

    2011-10-15

    Purpose: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. Methods: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. Results: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a ''patient'' to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. Conclusions: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.

  3. Response of the Hanford Combination Neutron Dosimeter in plutonium environments

    SciTech Connect

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.

    1996-02-01

    This report documents response characteristics and the development of dose algorithms for the Hanford Combination Neutron Dosimeter (HCNO) implemented on January 1, 1995. The HCND was accredited under the U.S. Department of Energy (DOE) Laboratory Accreditation Program (DOELAP) during 1994. The HCND employs two neutron dose components consisting of (1) an albedo thermoluminescent dosimeter (TLD), and (2) a track-etch dosimeter (TED). Response characteristics of these two dosimeter components were measured under the low-scatter conditions of the Hanford 318 Building Calibration Laboratory, and under the high-scatter conditions in the workplace at the Plutonium Finishing Plant (PFP). The majority of personnel neutron dose at Hanford (currently and historically) occurs at the PFP. National Institute of Standards and Technology (NIST) traceable sources were used to characterize dosimeter response in the laboratory. At the PFP, neutron spectra and dose-measuring instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters, were used to determine the neutron dose under several configurations from three different plutonium sources: (1) plutonium tetrafluoride, (2) plutonium metal, and (3) plutonium oxide. In addition, measurements were performed at many selected work locations. The HCNDs were included in all measurements. Comparison of dosimeter- and instrument-measured dose equivalents provided the data necessary to develop HCND dose algorithms and to assess the accuracy of estimated neutron dose under actual work conditions.

  4. Radiation measured with passive dosimeters in low Earth orbit

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Semones, E.; Gaza, R.; Weyland, M.

    begin center Radiation Measured with Passive Dosimeters in Low Earth Orbit end center begin center D Zhou 1 2 E Semones 1 R Gaza 1 2 M Weyland 1 end center begin center 1 Johnson Space Center - NASA 2101 Nasa Road 1 Houston 77058 USA end center begin center 2 Universities Space Research Association 2101 Nasa Parkway Houston 77058 USA end center begin center Abstract end center The linear energy transfer LET of particles in low Earth orbit LEO is extended from sim 0 1 to sim 1000 keV mu m water The best passive dosimeters for the radiation measurement are thermoluminescence dosimeters TLDs or optically stimulated luminescence dosimeters OSLDs for low LET and CR-39 plastic nuclear track detectors PNTDs for high LET Radiation quantities fluence absorbed dose dose equivalent and quality factor were measured with the passive dosimeters composed of TLDs OSLDs and CR-39 PNTDs for STS-114 mission This paper introduces the operation principles for TLDs OSLDs and CR-39 PNTDs describes the method to combine the results measured by TLDs OSLDs and CR-39 PNTDs and presents the results measured by different dosimeters for different LET band and that combined for all LET

  5. Mayak Film Dosimeter Response Studies, Part I: Measurements

    SciTech Connect

    Vasilenko, E. K.; Knyazev, V.; Gorelov, Mikhail; Smetanin, Mikhail; Scherpelz, Robert I.; Fix, John J.

    2007-09-01

    The Mayak Worker Dosimetry study is a joint Russian/US project to evaluate doses received by workers at the Mayak Production Association facilities from 1948-1972. A key investigation in this project is the characterization of responses of the three types of film dosimeters used to monitor workers during this time period. Experimental irradiations of the dosimeters were performed in the radiation calibration laboratories at the National Research Center for Environment and Health (GSF) in Munich, Germany. The irradiations used photon sources from X-ray beams with ten different energy distributions and with 60Co and 137Cs isotopic gamma sources. Irradiations were performed with the dosimeters on phantoms and free-in-air. The dosimeters and phantoms were also positioned at varying angles to the radiation beam. The result of the experiments was a thorough characterization of the dosimeter response as a function of photon energy and as a function of angle for energy and angular ranges that cover the conditions encountered in the Mayak workplaces. The characterization data were then available for use in developing correction factors which could be applied to worker dosimeter readings to provide a more accurate assessment of worker dose and estimates of doses to organs.

  6. Applicability of the polysulphone horizontal calibration to differently inclined dosimeters.

    PubMed

    Casale, Giuseppe R; Siani, Anna Maria; Diémoz, Henri; Kimlin, Michael G; Colosimo, Alfredo

    2012-01-01

    Polysulphone (PS) dosimetry has been a widely used technique for more than 30 years to quantify the erythemally effective UV dose received by anatomic sites (personal exposure). The calibration of PS dosimeters is an important issue as their spectral response is different from the erythemal action spectrum. It is performed exposing a set of PS dosimeters on a horizontal plane and measuring the UV doses received by dosimeters using calibrated spectroradiometers or radiometers. In this study, data collected during PS field campaigns (from 2004 to 2006), using horizontal and differently inclined dosimeters, were analyzed to provide some considerations on the transfer of the horizontal calibration to differently inclined dosimeters, as anatomic sites usually are. The role of sky conditions, of the angle of incidence between the sun and the normal to the slope, and of the type of surrounding surface on the calibration were investigated. It was concluded that PS horizontal calibrations apply to differently inclined dosimeters for incidence angles up to approximately 70° and for surfaces excluding ones with high albedo. Caution should be used in the application of horizontal calibrations for cases of high-incidence angle and/or high albedo surfaces.

  7. Potential High Resolution Dosimeters For MRT

    NASA Astrophysics Data System (ADS)

    Bräuer-Krisch, E.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Brochard, T.; Kamlowski, A.; Cellere, G.; Paccagnella, A.; Siegbahn, E. A.; Prezado, Y.; Martinez-Rovira, I.; Bravin, A.; Dusseau, L.; Berkvens, P.

    2010-07-01

    resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic® films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al2O3:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1×1 cm5 field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

  8. Potential High Resolution Dosimeters For MRT

    SciTech Connect

    Braeuer-Krisch, E.; Brochard, T.; Prezado, Y.; Bravin, A.; Berkvens, P.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Kamlowski, A.; Cellere, G.

    2010-07-23

    /s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

  9. PDT Dose Dosimeter for Pleural Photodynamic Therapy

    PubMed Central

    Kim, Michele M.; Darafsheh, Arash; Ahmad, Mahmoud; Finlay, Jarod C.; Zhu, Timothy C.

    2016-01-01

    PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), a PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously in the same treatment location. Light fluence and spectral data were rigorously compared to other methods of measurement (e.g. photodiode, multi-fiber spectroscopy contact probe) to assess the accuracy of the measurements as well as their uncertainty. Photosensitizer concentration was obtained by measuring the fluorescence of the sensitizer excited by the treatment light. Fluence rate based on the intensity of the laser spectrum was compared to the data obtained by direct measurement of fluence rate by a fiber-coupled photodiode. Phantom studies were done to obtain an optical property correction for the fluorescence signal. Measurements were performed in patients treated Photofrin for different locations in the pleural cavity. Multiple sites were measured to investigate the heterogeneity of the cavity and to provide cross-validation via relative dosimetry. This novel method will allow for accurate real-time determination of delivered PDT dose and improved PDT dosimetry. PMID:27053825

  10. PDT dose dosimeter for pleural photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Kim, Michele M.; Darafsheh, Arash; Ahmad, Mahmoud; Finlay, Jarod C.; Zhu, Timothy C.

    2016-03-01

    PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), a PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously in the same treatment location. Light fluence and spectral data were rigorously compared to other methods of measurement (e.g. photodiode, multi-fiber spectroscopy contact probe) to assess the accuracy of the measurements as well as their uncertainty. Photosensitizer concentration was obtained by measuring the fluorescence of the sensitizer excited by the treatment light. Fluence rate based on the intensity of the laser spectrum was compared to the data obtained by direct measurement of fluence rate by a fiber-coupled photodiode. Phantom studies were done to obtain an optical property correction for the fluorescence signal. Measurements were performed in patients treated Photofrin for different locations in the pleural cavity. Multiple sites were measured to investigate the heterogeneity of the cavity and to provide cross-validation via relative dosimetry. This novel method will allow for accurate real-time determination of delivered PDT dose and improved PDT dosimetry.

  11. Mixed-radiation discrimination using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Skopec, Marlene

    This work has developed, analyzed, and tested methods to discriminate among different types of radiation exposures using the glow curves of thermoluminescent dosimeters (TLDs). Thermoluminescent materials, Harshaw LiF:Mg,Ti (TLD-100) and CaF2:Tm (TLD-300), were exposed to pure proton, pure photon (x-ray and gamma), and mixed fields to examine and use differences in the thermoluminescent (TL) glow curve shapes for the purpose of radiation type discrimination. The effect of radiation type exposure order on thermoluminescent glow curve shape and the principle of superposition of glow curves were evaluated. Using computerized glow curve deconvolution (CGCD), no significant differences in glow curve shape or magnitude were found. Results demonstrated that the superposition of pure field glow curves is a valid method of simulating mixed field glow curves (i.e., the principle of superposition holds). Two robust and novel techniques for radiation type discrimination were developed: vector representation (VR) and principal component analysis (PCA). In VR, vectors were constructed from glow curve points and classified based on the vector inner product with a unit vector and vector magnitude. In PCA, variations in the glow curves due to radiation type are classified according to one principal component. The two methods were tested for accuracy using leave-one-out validation (LOOV) with classification based on the Mahalanobis distance. Overall, both techniques performed equally well, with over 92% accurate three category classification using the high temperature peak of TLD-100 and nearly 100% correct classification in TLD-300.

  12. Solid state neutron dosimeter for space applications

    NASA Technical Reports Server (NTRS)

    Entine, Gerald; Nagargar, Vivek; Sharif, Daud

    1990-01-01

    Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.

  13. Angular dependence of mammographic dosimeters in digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Bradley, Lena R.; Carton, Ann-Katherine; Maidment, Andrew D. A.

    2010-04-01

    Digital Breast Tomosynthesis (DBT) is an emerging imaging modality that combines tomography with conventional digital mammography. In developing DBT dosimetry, a direct application of mammographic dosimetry has appeal. However, DBT introduces rotation of the x-ray tube relative to the dosimeter, thus raising questions about the angular dependence of mammographic dosimeters. To measure this dependence, two ionization chambers, two solid-stated detectors, and one photodiode were rotated relative to an incident Mo/Mo x-ray beam. In this isocentric DBT simulation, the signal of each dosimeter was studied over an angular range of 180° for tube voltages of 26 to 34 kV. One ionization chamber was then modeled numerically to study the response to various monoenergetic beams. The results show that all dosimeters underestimate dose to varying degrees; solid-state detectors show the greatest angular dependence while ionization chambers show the least. Correction factors were computed from the data for isocentric DBT images using projection angles up to +/-25° these factors ranged from 1.0014 to 1.1380. The magnitude of the angular dependence generally decreased with increasing energy, as shown with both the measured and modeled data. As a result, the error arising in measuring DBT dose with a mammographic dosimeter varies significantly; it cannot always be disregarded. The use of correction factors may be possible but is largely impractical, as they are specific to the dosimeter, x-ray beam, and DBT geometry. Instead, an angle-independent dosimeter may be more suitable for DBT.

  14. DOE Radiological Calibrations Intercomparison Program: Results of fiscal year 1987

    SciTech Connect

    Cummings, F.M.; McDonald, J.C.

    1988-06-01

    This report presents the FY 1987 results of the radiological calibrations intercomparison program. The intercomparison operation is discussed, and the equipment is described, particularly the instrument set, the beta source set, and relevant calculations. Solutions to problems and improvements in the program are suggested, and conclusions are then introduced. 9 refs., 3 figs., 8 tabs.

  15. World commercial aircraft accidents

    SciTech Connect

    Kimura, C.Y.

    1993-01-01

    This report is a compilation of all accidents world-wide involving aircraft in commercial service which resulted in the loss of the airframe or one or more fatality, or both. This information has been gathered in order to present a complete inventory of commercial aircraft accidents. Events involving military action, sabotage, terrorist bombings, hijackings, suicides, and industrial ground accidents are included within this list. Included are: accidents involving world commercial jet aircraft, world commercial turboprop aircraft, world commercial pistonprop aircraft with four or more engines and world commercial pistonprop aircraft with two or three engines from 1946 to 1992. Each accident is presented with information in the following categories: date of the accident, airline and its flight numbers, type of flight, type of aircraft, aircraft registration number, construction number/manufacturers serial number, aircraft damage, accident flight phase, accident location, number of fatalities, number of occupants, cause, remarks, or description (brief) of the accident, and finally references used. The sixth chapter presents a summary of the world commercial aircraft accidents by major aircraft class (e.g. jet, turboprop, and pistonprop) and by flight phase. The seventh chapter presents several special studies including a list of world commercial aircraft accidents for all aircraft types with 100 or more fatalities in order of decreasing number of fatalities, a list of collision accidents involving commercial aircrafts, and a list of world commercial aircraft accidents for all aircraft types involving military action, sabotage, terrorist bombings, and hijackings.

  16. Intercomparison results for FIFE flux aircraft

    NASA Technical Reports Server (NTRS)

    Macpherson, J. I.; Grossman, R. L.; Kelly, R. D.

    1992-01-01

    Three atmospheric research aircraft were used to explore the atmospheric boundary layer during FIFE: the National Research Council of Canada Twin Otter, the National Center for Atmospheric Research (NCAR) King Air, and the University of Wyoming King Air. The aircraft were used to measure the mean and turbulent structure of the boundary layer and its variation with height, time, and space. These measurements are important to FIFE because they are being used to scale up point surface observations to landscape scales and because they can be used to relate satellite radiance measurements to boundary layer processes. Because the aircraft were used in coordinated flight patterns to investigate changes within and between intensive field campaigns, wing-to-wing intercomparisons were made so that measurements from one aircraft could be related to another. Intercomparisons were flown on 4 days in 1987 and 3 days in 1989. The eddy correlation measurements of the mixed layer fluxes of moisture and sensible heat were of particular interest to FIFE. Sensible heat fluxes agreed within 15 W/sq m and moisture fluxes agreed within 21 W/sq m. Mean wind component differences were within 1.0 m/s, air temperature within 0.3 C, and mixing ratio within 2 g/kg. Standard deviations showed similar good agreement, with mean differences generally less than 0.1 m/s for the wind components and 0.03 C for potential temperature. Intercomparisons between the NCAR King Air and the Twin Otter showed better agreement in 1989 than in 1987. Overall, the results suggest that data from the FIFE boundary layer aircraft will need little correction to account for instrument biases and spurious fluctuations.

  17. Stratospheric ozone intercomparison campaign (STOIC) 1989: Overview

    NASA Astrophysics Data System (ADS)

    Margitan, J. J.; Barnes, R. A.; Brothers, G. B.; Butler, J.; Burris, J.; Connor, B. J.; Ferrare, R. A.; Kerr, J. B.; Komhyr, W. D.; McCormick, M. P.; McDermid, I. S.; McElroy, C. T.; McGee, T. J.; Miller, A. J.; Owens, M.; Parrish, A. D.; Parsons, C. L.; Torres, A. L.; Tsou, J. J.; Walsh, T. D.; Whiteman, D.

    1995-05-01

    The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE II) aboard the Earth Radiation Budget Satellite and the total ozone mapping spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the

  18. Stratospheric Ozone Intercomparison Campaign (STOIC) 1989: Overview

    NASA Technical Reports Server (NTRS)

    Margitan, J. J.; Barnes, R. A.; Brothers, G. B.; Butler, J.; Burris, J.; Connor, B. J.; Ferrare, R. A.; Kerr, J. B.; Komhyr, W. D.; McCormick, M. P.; McDermid, I. S.; McElroy, C. T.; McGee, T. J.; Miller, A. J.; Owens, M.; Parrish, A. D.; Parsons, C. L.; Torres, A. L.; Tsou, J. J.; Walsh, T. D.

    1995-01-01

    The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE 2) aboard the Earth Radiation Budget Satellite and the Total Ozone Mapping Spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the

  19. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  20. Designing an Experimental "Accident"

    ERIC Educational Resources Information Center

    Picker, Lester

    1974-01-01

    Describes an experimental "accident" that resulted in much student learning, seeks help in the identification of nematodes, and suggests biology teachers introduce similar accidents into their teaching to stimulate student interest. (PEB)

  1. Luminescence techniques for dose reconstruction in accident situations: possibilites, limitations and uncertainties

    SciTech Connect

    Haskell, E.H.

    1996-12-31

    In a nuclear accident of even moderate size, locations will inevitably be exposed which do not have adequate monitoring. In these situations nontraditional dosimeters such as brick, tiles or other environmental materials have historically provided measurements against which models of transport and exposure could be tested. Given sufficient speed and accuracy, the utility of TL techniques applied to natural materials can extend well beyond model verification to a variety of dosimetric applications.

  2. Dose rate dependency of micelle leucodye 3D gel dosimeters

    NASA Astrophysics Data System (ADS)

    Vandecasteele, J.; Ghysel, S.; De Deene, Y.

    2010-11-01

    Recently a novel 3D radiochromic gel dosimeter was introduced which uses micelles to dissolve a leucodye in a gelatin matrix. Experimental results show that this 3D micelle gel dosimeter was found to be dose rate dependent. A maximum difference in optical dose sensitivity of 70% was found for dose rates between 50 cGy min-1 and 400 cGy min-1. A novel composition of 3D radiochromic dosimeter is proposed composed of gelatin, sodium dodecyl sulphate, chloroform, trichloroacetic acid and leucomalachite green. The novel gel dosimeter formulation exhibits comparable radio-physical properties in respect to the composition previously proposed. Nevertheless, the novel formulation was found to be still dose rate dependent. A maximum difference of 33% was found for dose rates between 50 cGy min-1 and 400 cGy min-1. On the basis of these experimental results it is concluded that the leucodye micelle gel dosimeter is still unsatisfactory for clinical radiation therapy dose verifications. Some insights in the physico-chemical mechanisms were obtained and are discussed.

  3. Effect of bloom strength on radiochromic gel dosimeters

    NASA Astrophysics Data System (ADS)

    Ebenezer Suman Babu, S.; Ravindran, B. Paul

    2015-01-01

    The Fricke gel dosimeter has been the widely used dosimeter among the gel dosimeters because of its dose response characteristics and easy preparation. The ferrous to ferric conversion that happens in this gel dosimeter on irradiation, corresponds to the absorbed dose of radiation. Gel dosimetry in India is not moving forward because of the import restrictions on the commercially available high bloom strength gelatin (imported 300 bloom). The feasibility of using Fricke gel dosimeter prepared with the locally available gelatin of 240 bloom and 200 bloom were compared with the 300 bloom gelatin taken as standard. The gel samples were prepared with 5% gelatin by weight and irradiated with 60Co gamma radiation for a dose range from 0-3 Gy used clinically. The optical absorption of gel samples were analyzed using spectrophotometer at 585 nm and dose response curves were generated. The results indicate that Fricke gels prepared with 240 bloom have linear dose response and comparable with those prepared with 300 bloom but the use of gels prepared with 200 bloom was found to be limited because of its poor optical transmittance.

  4. A real-time pulsed photon dosimeter

    NASA Astrophysics Data System (ADS)

    Brown, David; Olsher, Richard H.; Eisen, Yosef; Rodriguez, Joseph F.

    1996-02-01

    Radiation sources producing short pulses of photon radiation are now widespread. Such sources include electron and proton linear accelerators, betatrons, synchrotrons, and field-emission impulse generators. It is often desirable to measure leakage and skyshine radiation from such sources in real time, on a single-pulse basis as low as 8.7 nGy (1 μR) per pulse. This paper describes the design and performance of a prototype, real-time, pulsed photon dosimeter (PPD) capable of single-pulse dose measurements over the range from 3.5 nGy to 3.5 μGy (0.4 to 400 μR). The PPD may also be operated in a multiple-pulse mode that integrates the dose from a train of radiation pulses over a 3-s period. A pulse repetition rate of up to 300 Hz is accommodated. The design is eminently suitable for packaging as a lightweight, portable, survey meter. The PPD uses a CdWO 4 scintillator optically coupled to a photodiode to generate a charge at the diode output. A pulse amplifier converts the charge to a voltage pulse. A digitizer circuit generates a burst of logic pulses whose number is proportional to the peak value of the voltage pulse. The digitizer output is recorded by a pulse counter and suitably displayed. A prototype PPD was built for testing and evaluation purposes. The performance of the PPD was evaluated with a variety of pulsed photon sources. The dynamic range, energy response, and response to multiple pulses were characterized. The experimental data confirm the viability of the PPD for pulsed photon dosimetry.

  5. Monitoring of environmental UV radiation by biological dosimeters.

    PubMed

    Ronto, G; Berces, A; Grof, P; Fekete, A; Kerekgyarto, T; Gaspar, S; Stick, C

    2000-01-01

    As a consequence of the stratospheric ozone layer depletion biological systems can be damaged due to increased UV-B radiation. The aim of biological dosimetry is to establish a quantitative basis for the risk assessment of the biosphere. DNA is the most important target molecule of biological systems having special sensitivity against short wavelength components of the environmental radiation. Biological dosimeters are usually simple organisms, or components of them, modeling the cellular DNA. Phage T7 and polycrystalline uracil biological dosimeters have been developed and used in our laboratory for monitoring the environmental radiation in different radiation conditions (from the polar to equatorial regions). Comparisons with Robertson-Berger (RB) meter data, as well as with model calculation data weighted by the corresponding spectral sensitivities of the dosimeters are presented. Suggestion is given how to determine the trend of the increase in the biological risk due to ozone depletion.

  6. Development and evaluation of polycrystalline cadmium telluride dosimeters for accurate quality assurance in radiation therapy

    NASA Astrophysics Data System (ADS)

    Oh, K.; Han, M.; Kim, K.; Heo, Y.; Moon, C.; Park, S.; Nam, S.

    2016-02-01

    For quality assurance in radiation therapy, several types of dosimeters are used such as ionization chambers, radiographic films, thermo-luminescent dosimeter (TLD), and semiconductor dosimeters. Among them, semiconductor dosimeters are particularly useful for in vivo dosimeters or high dose gradient area such as the penumbra region because they are more sensitive and smaller in size compared to typical dosimeters. In this study, we developed and evaluated Cadmium Telluride (CdTe) dosimeters, one of the most promising semiconductor dosimeters due to their high quantum efficiency and charge collection efficiency. Such CdTe dosimeters include single crystal form and polycrystalline form depending upon the fabrication process. Both types of CdTe dosimeters are commercially available, but only the polycrystalline form is suitable for radiation dosimeters, since it is less affected by volumetric effect and energy dependence. To develop and evaluate polycrystalline CdTe dosimeters, polycrystalline CdTe films were prepared by thermal evaporation. After that, CdTeO3 layer, thin oxide layer, was deposited on top of the CdTe film by RF sputtering to improve charge carrier transport properties and to reduce leakage current. Also, the CdTeO3 layer which acts as a passivation layer help the dosimeter to reduce their sensitivity changes with repeated use due to radiation damage. Finally, the top and bottom electrodes, In/Ti and Pt, were used to have Schottky contact. Subsequently, the electrical properties under high energy photon beams from linear accelerator (LINAC), such as response coincidence, dose linearity, dose rate dependence, reproducibility, and percentage depth dose, were measured to evaluate polycrystalline CdTe dosimeters. In addition, we compared the experimental data of the dosimeter fabricated in this study with those of the silicon diode dosimeter and Thimble ionization chamber which widely used in routine dosimetry system and dose measurements for radiation

  7. Angular dependence of the nanoDot OSL dosimeter

    SciTech Connect

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-07-15

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight/OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system. Methods: Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX. Results: When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found. Conclusions: A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions.

  8. Implanted Dosimeters Identify Radiation Overdoses During IMRT for Prostate Cancer

    SciTech Connect

    Den, Robert B.; Nowak, Kamila; Buzurovic, Ivan; Cao Junsheng; Harrison, Amy S.; Lawrence, Yaacov R.; Dicker, Adam P.; Showalter, Timothy N.

    2012-07-01

    Purpose: Image-guided dose-escalated radiotherapy is the standard of care for the treatment of prostate cancer. Although many published methods are available that account for prostate motion during delivery, evidence demonstrating that the planned dose is actually delivered on a daily basis is lacking. We report our initial clinical experience using implantable dosimeters to quantify and adjust the dose received during intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients undergoing IMRT with cone-beam computed tomography (CT) image guidance for prostate cancer had the dose verification system with radiopaque metal-oxide-semiconductor field effect transistor dosimeters implanted before treatment planning. All patients underwent planning with CT simulation in the supine position with custom immobilization, and the implanted dosimeters were located in the IMRT plans. The predicted dose for each dosimeter was defined and compared with the wireless readings before and after each treatment session. Investigations by physicians and medical physicists were initiated for two or more discrepancies >6% for any five consecutive fractions or for any discrepancy {>=}10%. Results: Using implanted in vivo dosimeters, dose measurements consistently >6% greater than the predicted values were observed during treatment for 3 of 20 prostate cancer patients who received IMRT with daily image guidance. A review of the daily cone-beam CT images revealed acceptable alignment of the prostate target volumes and implanted dosimeters but identified significant anatomic changes within the treated region. Repeat CT simulation and RT planning was performed, with resolution of the dose discrepancies in all 3 cases with the adoption of a new IMRT plan. Conclusions: Our report illustrates the potential effect of implanted in vivo dosimetry for prostate IMRT and emphasizes the importance of careful planning and delivery with attention to systematic shifts or anatomic

  9. Angular dependence of the nanoDot OSL dosimeter

    PubMed Central

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-01-01

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight∕OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system.Methods: Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX.Results: When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found.Conclusions: A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions. PMID:21858992

  10. Monte Carlo simulation experiments on box-type radon dosimeter

    NASA Astrophysics Data System (ADS)

    Jamil, Khalid; Kamran, Muhammad; Illahi, Ahsan; Manzoor, Shahid

    2014-11-01

    Epidemiological studies show that inhalation of radon gas (222Rn) may be carcinogenic especially to mine workers, people living in closed indoor energy conserved environments and underground dwellers. It is, therefore, of paramount importance to measure the 222Rn concentrations (Bq/m3) in indoors environments. For this purpose, box-type passive radon dosimeters employing ion track detector like CR-39 are widely used. Fraction of the number of radon alphas emitted in the volume of the box type dosimeter resulting in latent track formation on CR-39 is the latent track registration efficiency. Latent track registration efficiency is ultimately required to evaluate the radon concentration which consequently determines the effective dose and the radiological hazards. In this research, Monte Carlo simulation experiments were carried out to study the alpha latent track registration efficiency for box type radon dosimeter as a function of dosimeter's dimensions and range of alpha particles in air. Two different self developed Monte Carlo simulation techniques were employed namely: (a) Surface ratio (SURA) method and (b) Ray hitting (RAHI) method. Monte Carlo simulation experiments revealed that there are two types of efficiencies i.e. intrinsic efficiency (ηint) and alpha hit efficiency (ηhit). The ηint depends upon only on the dimensions of the dosimeter and ηhit depends both upon dimensions of the dosimeter and range of the alpha particles. The total latent track registration efficiency is the product of both intrinsic and hit efficiencies. It has been concluded that if diagonal length of box type dosimeter is kept smaller than the range of alpha particle then hit efficiency is achieved as 100%. Nevertheless the intrinsic efficiency keeps playing its role. The Monte Carlo simulation experimental results have been found helpful to understand the intricate track registration mechanisms in the box type dosimeter. This paper explains that how radon concentration from the

  11. Strategy for finding new materials for ESR dosimeters

    PubMed

    Ikeya; Hassan; Sasaoka; Kinoshita; Takaki; Yamanaka

    2000-05-01

    The right strategy for finding a new ESR dosimetric material sensitive to radiation is to follow the orthodox procedures used in the development of thermoluminescence dosimeters (TLD) and phosphorescence studies. Modern procedures used in materials sciences, such as computer calculation of molecular orbitals (MO), should be employed to estimate the ESR and optical properties of prospective materials. Radiation effects in lithium and magnesium sulfates and metal salts of organic acids, such as lithium and magnesium lactates, have been investigated in search for tissue-equivalent dosimeter with a large G value.

  12. Measurement of a PAGAT gel dosimeter by ultrasound computed tomography

    NASA Astrophysics Data System (ADS)

    Khoei, S.; Trapp, J. V.; Langton, C. M.

    2013-06-01

    In this work we used a 3D quantitative CT ultrasound imaging system to characterise polymer gel dosimeters. The system comprised of two identical 5 MHz 128 element phased-array ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound signals were generated and received using an Olympus Omniscan unit. Dose sensitivity of attenuation and time of flight ultrasonic parameters were assessed using this system.

  13. Intercomparison of hydrologic processes in global climate models

    NASA Technical Reports Server (NTRS)

    Lau, W. K.-M.; Sud, Y. C.; Kim, J.-H.

    1995-01-01

    In this report, we address the intercomparison of precipitation (P), evaporation (E), and surface hydrologic forcing (P-E) for 23 Atmospheric Model Intercomparison Project (AMIP) general circulation models (GCM's) including relevant observations, over a variety of spatial and temporal scales. The intercomparison includes global and hemispheric means, latitudinal profiles, selected area means for the tropics and extratropics, ocean and land, respectively. In addition, we have computed anomaly pattern correlations among models and observations for different seasons, harmonic analysis for annual and semiannual cycles, and rain-rate frequency distribution. We also compare the joint influence of temperature and precipitation on local climate using the Koeppen climate classification scheme.

  14. Visualization of Traffic Accidents

    NASA Technical Reports Server (NTRS)

    Wang, Jie; Shen, Yuzhong; Khattak, Asad

    2010-01-01

    Traffic accidents have tremendous impact on society. Annually approximately 6.4 million vehicle accidents are reported by police in the US and nearly half of them result in catastrophic injuries. Visualizations of traffic accidents using geographic information systems (GIS) greatly facilitate handling and analysis of traffic accidents in many aspects. Environmental Systems Research Institute (ESRI), Inc. is the world leader in GIS research and development. ArcGIS, a software package developed by ESRI, has the capabilities to display events associated with a road network, such as accident locations, and pavement quality. But when event locations related to a road network are processed, the existing algorithm used by ArcGIS does not utilize all the information related to the routes of the road network and produces erroneous visualization results of event locations. This software bug causes serious problems for applications in which accurate location information is critical for emergency responses, such as traffic accidents. This paper aims to address this problem and proposes an improved method that utilizes all relevant information of traffic accidents, namely, route number, direction, and mile post, and extracts correct event locations for accurate traffic accident visualization and analysis. The proposed method generates a new shape file for traffic accidents and displays them on top of the existing road network in ArcGIS. Visualization of traffic accidents along Hampton Roads Bridge Tunnel is included to demonstrate the effectiveness of the proposed method.

  15. The SPARC Intercomparison of Middle Atmosphere Climatologies

    NASA Technical Reports Server (NTRS)

    Randel, William; Fleming, Eric; Geller, Marvin; Gelman, Mel; Hamilton, Kevin; Karoly, David; Ortland, Dave; Pawson, Steve; Swinbank, Richard; Udelhofen, Petra

    2003-01-01

    Our current confidence in 'observed' climatological winds and temperatures in the middle atmosphere (over altitudes approx. 10-80 km) is assessed by detailed intercomparisons of contemporary and historic data sets. These data sets include global meteorological analyses and assimilations, climatologies derived from research satellite measurements, and historical reference atmosphere circulation statistics. We also include comparisons with historical rocketsonde wind and temperature data, and with more recent lidar temperature measurements. The comparisons focus on a few basic circulation statistics, such as temperature, zonal wind, and eddy flux statistics. Special attention is focused on tropical winds and temperatures, where large differences exist among separate analyses. Assimilated data sets provide the most realistic tropical variability, but substantial differences exist among current schemes.

  16. Inter-comparison of automatic rain gauges

    NASA Technical Reports Server (NTRS)

    Nystuen, Jeffrey A.

    1994-01-01

    The Ocean Acoustics Division (OAD) of the Atlantic Oceanographic and Meteorological Laboratory (AOML), in cooperation with NOAA/NESDIS and NASA, has deployed six rain gauges for calibration and intercomparison purposes. These instruments include: (1) a weighing rain gauge, (2) a RM Young Model 50202 capacitance rain gauge, (3) a ScTI ORG-705 (long path) optical rain gauge, (4) a ScTI ORG-105 (mini-ORG) optical rain gauge, (5) a Belfort Model 382 tipping bucket rain gauge, and (6) a Distromet RD-69 disdrometer. The system has been running continuously since July 1993. During this time period, roughly 150 events with maximum rainfall rate over 10 mm/hr and 25 events with maximum rainfall rates over 100 mm/hr have been recorded. All rain gauge types have performed well, with intercorrelations 0.9 or higher. However, limitations for each type of rain gauge have been observed.

  17. Intercomparison of measurements of stratospheric hydrogen fluoride

    NASA Technical Reports Server (NTRS)

    Mankin, William G.; Coffey, M. T.; Chance, K. V.; Traub, W. A.; Carli, B.; Mencaraglia, F.; Piccioli, S.; Farmer, C. B.; Seals, R. K.

    1990-01-01

    Observations of the vertical profile of hydrogen fluoride (HF) vapor in the stratosphere and of the vertical column amounts of HF above certain altitudes were made using a variety of spectroscopic instruments in the 1982 and 1983 Balloon Intercomparison Campaigns. Both emission instruments working in the far-infrared spectral region and absorption instruments using solar occultation in the 2.5-micron region were employed. No systematic differences were seen in results from the two spectral regions. A mean profile from 20 - 45 km is presented, with uncertainties ranging from 20 to 50 percent. Total columns measured from ground and from 12 km are consistent with the profile if the mixing ratio for HF is small in the troposphere and low stratosphere.

  18. Intercomparison of NO sub 2 measurement techniques

    SciTech Connect

    Fehsenfeld, F.C.; Williams, E.J.; Buhr, M.P.; Hubler, G.; Langford, A.O.; Murphy, P.C. Univ. of Colorado, Boulder ); Parrish, D.D.; Norton, R.B.; Fahey, D.W. ); Drummond, J.W.; Mackay, G.I. ); Schiff, H.I. York Univ., North York, Ontario ); Roychowdhury, U.K.; Hovermale, C.; Mohnen, V.A.; Demerjian, K.L. ); Galvin, P.J. ); Calvert, J.G.; Ridley, B.A.; Grahek, F.; Heikes, B.G.; Kok, G.L.; Shetter, J.D.; Walega, J.G. ); Elsworth, C.M. )

    1990-03-20

    An intercomparison was made near Niwot Ridge, Colorado, of three different instruments for measuring NO{sub 2} at low concentrations in ambient air: (1) the photolysis/chemiluminescence (PC) instrument, (2) the tunable diode laser absorption spectrometer (TDLAS), and (3) the Luminox instrument. Calibrated mixtures of NO{sub 2} in air and NO{sub 2} with possible interferants (HNO{sub 3}, peroxyacetyl nitrate (PAN), H{sub 2}O{sub 2}, n-propyl nitrate, and O{sub 3}) were provided in simultaneous tests. Several conclusions were reached concerning the performance of these instruments during this intercomparison: (1) For NO{sub 2} levels above 2 parts per billion by volume (ppbv), similar results were obtained for all instruments; (2) Below 2 ppbv, the expected interferences from ozone and PAN influenced the NO{sub 2} measurements made using the Luminox instruments. Those interferences were sufficiently consistent that they could be corrected for by using the measured values of O{sub 3} and PAN down to about 0.3 ppbv NO{sub 2}; (3) The ozone interference on the Luminox instruments was removed by an ozone scrubber placed in the sampled air stream of the Luminox instrument. However, this did not remove PAN. In addition, the scrubber appeared to remove about 50% of the NO{sub 2} as well; (4) Although no interferences were identified for the TDLAS technique, care must be taken in the data analysis near (or below) the detection limit for the instrument. At these levels the data reduction program provided with the TDLAS will tend to find background noise that is correlated with the reference NO{sub 2} spectrum and calculate levels of NO{sub 2} that are too high; (5) No interferences or artifacts were found for the final results reported by the PC technique.

  19. The Pliocene Model Intercomparison Project - Phase 2

    NASA Astrophysics Data System (ADS)

    Haywood, Alan; Dowsett, Harry; Dolan, Aisling; Rowley, David; Abe-Ouchi, Ayako; Otto-Bliesner, Bette; Chandler, Mark; Hunter, Stephen; Lunt, Daniel; Pound, Matthew; Salzmann, Ulrich

    2016-04-01

    The Pliocene Model Intercomparison Project (PlioMIP) is a co-ordinated international climate modelling initiative to study and understand climate and environments of the Late Pliocene, and their potential relevance in the context of future climate change. PlioMIP examines the consistency of model predictions in simulating Pliocene climate, and their ability to reproduce climate signals preserved by geological climate archives. Here we provide a description of the aim and objectives of the next phase of the model intercomparison project (PlioMIP Phase 2), and we present the experimental design and boundary conditions that will be utilised for climate model experiments in Phase 2. Following on from PlioMIP Phase 1, Phase 2 will continue to be a mechanism for sampling structural uncertainty within climate models. However, Phase 1 demonstrated the requirement to better understand boundary condition uncertainties as well as uncertainty in the methodologies used for data-model comparison. Therefore, our strategy for Phase 2 is to utilise state-of-the-art boundary conditions that have emerged over the last 5 years. These include a new palaeogeographic reconstruction, detailing ocean bathymetry and land/ice surface topography. The ice surface topography is built upon the lessons learned from offline ice sheet modelling studies. Land surface cover has been enhanced by recent additions of Pliocene soils and lakes. Atmospheric reconstructions of palaeo-CO2 are emerging on orbital timescales and these are also incorporated into PlioMIP Phase 2. New records of surface and sea surface temperature change are being produced that will be more temporally consistent with the boundary conditions and forcings used within models. Finally we have designed a suite of prioritized experiments that tackle issues surrounding the basic understanding of the Pliocene and its relevance in the context of future climate change in a discrete way.

  20. Influence of preparation and calibration method of PAGAT dosimeter on TSE MR readout results

    NASA Astrophysics Data System (ADS)

    Vávrů, K.; Dvořák, P.; Tintěra, J.; Spěváček, V.

    2013-06-01

    In this study PAGAT dosimeter evaluation by TSE sequence was tested. PAGAT dosimeter preparation procedure was modified to increase the dosimeter sensitivity. Because THPC reacts with gelatin, adding THPC to monomer solution prior to dissolved gelatine helps exploit THPC as an antioxidant. Turbo spin echo sequence enables to evaluate gel dosimeter with 3D equidistant resolution in a reasonable scanning time. Glass walls of the phantom cause problems both by computing inaccuracies and MR imaging artefacts. The inner dosimeter volume is not affected by these inaccuracies and should be used for radiotherapy plan verification.

  1. Deconnable self-reading pocket dosimeter containment with self-contained light

    DOEpatents

    Stevens, Robyn L.; Arnold, Greg N.; McBride, Ryan G.

    1996-01-01

    A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.

  2. Deconnable self-reading pocket dosimeter containment with self-contained light

    SciTech Connect

    Stevens, R.L.; Arnold, G.N.; McBride, R.G.

    1995-12-31

    A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.

  3. The European Light Dosimeter Network: four years of measurements.

    PubMed

    Lebert, Michael; Schuster, Martin; Häder, Donat Peter

    2002-02-01

    The European Light Dosimeter Network (ELDONET) has now been functional for more than four years. The network is based on dosimeters which measure radiation in three biologically relevant wavelength bands (UV-B, 280-315 nm; UV-A, 315-400 nm; and Photosynthetic Active Radiation, PAR, 400-700 nm). The ELDONET network is currently based on 33 stations with 40 instruments. The distribution of the instruments all over Europe allows measurement of the latitudinal and longitudinal light climate distribution. In addition, several instruments are active in South America, New Zealand, India, Africa and Japan. With some exceptions, the measured yearly doses depend on the latitude. While the maximal daily doses are almost comparable from station to station, seasonal changes and the different maximal solar zenith angles account for the differences in total yearly doses. Ratioing between UV-B and PAR allows the detection of subtle changes in the local light climate, due, for example, to mini-ozone holes encountered in northern Europe during spring. Comparison of satellite ozone data with terrestrial ELDONET measurements revealed an overall weak correlation between these data sets. However, local weather conditions, solar zenith angle and latitude as well as reflectivity (i.e. clouds and aerosol; satellite data) show a much stronger correlation to the doses received. The close relationship between the spectral sensitivity of the UV-B sensor used in the ELDONET dosimeter and the CIE erythemal action spectrum allows determination of the erythemal dose on the basis of the dosimeter readings.

  4. Characterization of a reusable PRESAGE® 3D dosimeter

    NASA Astrophysics Data System (ADS)

    Juang, T.; Adamovics, J.; Oldham, M.

    2015-01-01

    This study investigates a reusable PRESAGE® 3D dosimeter (Presage-RU), which would improve cost-effectiveness and facilitate wider implementation of comprehensive, high resolution 3D dosimetry. Small (1x1x4.5 cm) and large (8 cm diameter, 4.5 cm length) sample dosimeters were irradiated multiple times to characterize dose response (i.e. radiation-induced change in optical density (ΔOD)), optical clearing rate, and dose distribution stability. Presage- RU exhibited an initial dose response sensitivity of 0.0119 ΔOD/(cm-Gy), a reduction in response with subsequent irradiations, and a small, permanent ΔOD (~1-6% of initial signal) following each irradiation. Dosimeters optically cleared at an exponential rate (average T1/2 = 24.8±3.6 h), and were effectively cleared after ~5-8 days. 3D gamma analysis (3%/3mm, 10% dose threshold) of a 4-field box plan applied to the large dosimeter showed good agreement following initial irradiation (96.6% passing), but a reduction in passing rate (89.1% passing) with subsequent irradiation. Further study is warranted to fully assess and quantify the performance of Presage-RU for repeat irradiations.

  5. Improvements in opti-chromic dosimeters for radiation processing

    NASA Astrophysics Data System (ADS)

    Humpherys, K. C.; Kantz, A. D.

    "Opti-Chromic" dosimeters consisting of radiachromic dye in flourinated polymer tubing have been introduced as a dosimetry system in the range from 10 1 to 5 × 10 4 Gy. Batches of "Opti-Chromic" dosimeters have been produced to evaluate performance under large scale industrial conditions. A systematic study was undertaken to determine the effect of various dosimeter parameters on radiation sensitivity, shelf life, and response characteristics at the higher absorbed doses. These parameters were (A) Type of flourinated polymer tubing; (B) Organic solvent used to activate the radiachromic dye; (C) Concentration of radiachromic dye; (D) Additives to provide proper viscosity, color stability, and high-dose response. Prototype batches were produced and experimental dosimeters exposed to a range of absorbed doses and the response measured as a function of shelf life and dose. The results of the study are presented, and an improved formulation recommended for application to Food Processing. Other formulations may be of value in specific requirements of sensitivity or temperature.

  6. Reevaluation of the employment of Fick's law for diffusion dosimeters.

    PubMed

    Cross, John H

    2003-04-15

    This paper reconsiders the means of applying Fick's first law to passive diffusion dosimeters. The performance of the organic vapor monitor (OVM), a commercially available dosimeter, is modeled in terms of gradients, which are generated by evaporating a compound from the dosimeter. The fluxes induced by the gradients are determined gravimetrically. The ratio of a flux and a gradient is reported as a Fick's law proportionality constant, the sampling rate. The sampling rate for the gradient across the OVM is calculated from a harmonic average of the sampling rates of two other gradients. The OVM sampling rates for nine compounds determined by the new methodology agree well with published values. Further analysis of the other two gradients provides a value for an apparent reduction in sampling rate in the absence of airflow across the dosimeter (a boundary-layer effect). Procedures are also described to validate measured air concentrations by determining the sampling rates before and after exposure and by correcting for the boundary-layer effect. Sampling rates were found to be stable during 2-4-day exposures in a variety of conditions. In contrast, the boundary-layer effect caused the measured air concentrations to be substantially lower than the estimated true air concentrations.

  7. Hanford Personnel Dosimeter supporting studies FY-1980. [Lead abstract

    SciTech Connect

    Endres, G.W.R.; Cummings, F.M.; Aldrich, J.M.; Thorson, M.R.; Kathren, R.L.

    1981-02-01

    Separate abstracts were prepared for the 10 sections of this report which describe fundamental characteristics of the Hanford multipurpose personnel dosimeter (HMPD). Abstracts were not prepared for Appendix A and Appendix B which deal with calculated standard deviations for 100 mrem mixed field exposures and detailed calculations of standard deviations, respectively. (KRM)

  8. Thin thermoluminescent dosimeter and method of making same

    DOEpatents

    Simons, Gale G.; DeBey, Timothy M.

    1987-01-01

    An improved thermoluminescent ionizing radiation dosimeter of solid, extremely thin construction for more accurate low energy beta dosimetry is provided, along with a method of fabricating the dosimeter. In preferred forms, the dosimeter is a composite including a backing support (which may be tissue equivalent) and a self-sustaining body of solid thermoluminescent material such as LiF having a thickness of less than about 0.25 millimeters and a volume of at least about 0.0125 mm.sup.3. In preferred fabrication procedures, an initially thick (e.g., 0.89 millimeters) TLD body is wet sanded using 600 grit or less sandpaper to a thickness of less than about 0.25 millimeters, followed by adhesively attaching the sanded body to an appropriate backing. The sanding procedure permits routine production of extremely thin (about 0.05 millimeters) TLD bodies, and moreover serves to significantly reduce non-radiation-induced thermoluminescence. The composite dosimeters are rugged in use and can be subjected to annealing temperatures for increased accuracy.

  9. An angular dependent neutron effective-dose-equivalent dosimeter

    NASA Astrophysics Data System (ADS)

    Veinot, Kenneth Guy

    The effective-dose-equivalent (EDE) is a strong function of angular orientation in a radiation field. Detection systems that attempt to measure the EDE directly would be desirable. Historically, dosimeters have been designed to respond as isotropically as possible in a radiation field. However, since the EDE is strongly dependent upon the incident angle of the radiation, past designs are no longer desirable for personal radiation dosimetry. In addition, the EDE is a function of incident neutron energy. CR-39 foils are commonly used neutron detectors. Neutrons produce tracks in CR-39 (allyl diglycol polycarbonate) detectors over a wide energy range. Through chemical or electrochemical etching, these tracks can be enlarged and counted. From this track count, the fluence of neutrons incident on the CR-39 foils may be inferred. Thermoluminescent dosimeters (TLDs) are another method of neutron detection. Both of these detectors have angular response properties. In the present work, calculations of EDE were compared to calculations and measurements of the angular responses of CR-39 and TLD neutron dosimeters. The measurements used a variety of neutron sources, each with its own characteristic energy spectrum. This research resulted in a neutron personal dosimeter prototype whose angular response properties resembled the angular response of EDE.

  10. Two methods for examining angular response of personnel dosimeters

    SciTech Connect

    Plato, P.; Leib, R.; Miklos, J.

    1988-06-01

    The American National Standard ANSI N13.11-1983 is used to test the accuracy (bias plus precision) of dosimetry processors as part of the dosimetry accreditation program of the National Voluntary Laboratory Accreditation Program (NVLAP). Section 3.8 of the ANSI N13.11-1983 standard requires that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. The NVLAP accreditation program excluded Section 3.8, and thus no angular response data have been generated in an organized fashion. The objective of this project is to examine the feasibility of two alternative methods to test the angular response of personnel dosimeters. The first alternative involves static irradiations with the dosimeters at fixed angles to a radiation source. The second alternative involves dynamic irradiations with the dosimeters mounted on a rotating phantom. A Panasonic UD-802 personnel dosimetry system** was used to generate data to examine both alternatives. The results lead to two major conclusions. Firstly, Section 3.8 of the ANSI N13.11-1983 standard should be amended to require a pass/fail test for angular response. Secondly, a comparison between angular response data generated with a fixed or a rotating phantom shows that the rotating phantom is the more cost-effective method.

  11. Portable battery-free charger for radiation dosimeters

    DOEpatents

    Manning, Frank W.

    1984-01-01

    This invention is a novel portable charger for dosimeters of the electrometer type. The charger does not require batteries or piezoelectric crystals and is of rugged construction. In a preferred embodiment, the charge includes a housing which carries means for mounting a dosimeter to be charged. The housing also includes contact means for impressing a charging voltage across the mounted dosimeter. Also, the housing carries a trigger for operating a charging system mounted in the housing. The charging system includes a magnetic loop including a permanent magnet for establishing a magnetic field through the loop. A segment of the loop is coupled to the trigger for movement thereby to positions opening and closing the loop. A coil inductively coupled with the loop generates coil-generated voltage pulses when the trigger is operated to open and close the loop. The charging system includes an electrical circuit for impressing voltage pulses from the coil across a capacitor for integrating the pulses and applying the resulting integrated voltage across the above-mentioned contact means for charging the dosimeter.

  12. Radioxenon standards used in laboratory inter-comparisons.

    PubMed

    Gohla, H; Auer, M; Cassette, Ph; Hague, R K; Lechermann, M; Nadalut, B

    2016-03-01

    Preparation methods for (133)Xe standards of activity concentration and the results of the 2014 (133)Xe laboratory inter-comparison exercise are described. One element of the quality assurance/quality control (QA/QC) program for laboratories of the International Monitoring System (IMS) will be regular inter-comparison exercises. However, until recently, no activity concentration standards for benchmarking were available. Therefore, two (133)Xe activity concentration reference standards were produced independently by Idaho National Laboratory and Seibersdorf Laboratories and used for the 2014 laboratory inter-comparison exercise. The preparation of a complementary (127)Xe activity concentration standard as well as a (127)Xe laboratory inter-comparison exercise suggests (127)Xe as a suitable isotope for QA/QC of remote IMS noble gas stations.

  13. International NMR-based Environmental Metabolomics Intercomparison Exercise

    EPA Science Inventory

    Several fundamental requirements must be met so that NMR-based metabolomics and the related technique of metabonomics can be formally adopted into environmental monitoring and chemical risk assessment. Here we report an intercomparison exercise which has evaluated the effectivene...

  14. Identification of irradiated foodstuffs: results of a European test intercomparison.

    PubMed

    Raffi, J; Belliardo, J J; Agnel, J P; Vincent, P

    1993-01-01

    The results of an intercomparison, organized by the Community Bureau of Reference (Commission of the European Communities), on the use of Electron Spin Resonance spectroscopy for the identification of irradiated food are presented. A qualitative intercomparison was carried out using beef and trout bones, sardine scales, pistachio nut shells, dried grapes and papaya. Protocols are proposed for meat bones, fish bones (with some restrictions) and fruits such as dried grapes and papaya. The protocol for pistachio nuts and fruits such strawberries is more complicated and further research is needed prior the organization of future intercomparisons. A quantitative intercomparison on poultry bones was also organized. Laboratories were able to distinguish between chicken bones irradiated at 1 to 3 kGy or 7 to 10 kGy.

  15. Laser accidents: Being Prepared

    SciTech Connect

    Barat, K

    2003-01-24

    The goal of the Laser Safety Officer and any laser safety program is to prevent a laser accident from occurring, in particular an injury to a person's eyes. Most laser safety courses talk about laser accidents, causes, and types of injury. The purpose of this presentation is to present a plan for safety offices and users to follow in case of accident or injury from laser radiation.

  16. LET effects following neutron irradiation of lithium formate EPR dosimeters.

    PubMed

    Malinen, Eirik; Waldeland, Einar; Hole, Eli Olaug; Sagstuen, Einar

    2006-03-13

    Lithium formate electron paramagnetic resonance (EPR) dosimeters were irradiated using 60Co gamma-rays or fast neutrons to doses ranging from 5 to 20 Gy and investigated by EPR spectroscopy. Using a polynomial fitting procedure in order to accurately analyze peak-to-peak line widths of first derivative EPR spectra, dosimeters irradiated with neutrons had on average 4.4+/-0.9% broader EPR resonance lines than gamma-irradiated dosimeters. The increase in line width was slightly asymmetrical. Computer simulated first derivative polycrystalline EPR spectra of a *CO2- radical gave very good reconstructions of experimental spectra of irradiated dosimeters. The spectrum simulations could then be used as a tool to investigate the line broadening observed following neutron irradiation. It was shown that an increase in the simulated Lorentzian line width could explain both the observed line broadening and the asymmetrical effect. The ratio of the peak-to-peak amplitude of first derivative EPR spectra obtained at two different microwave powers (20 and 0.5 mW) was 7.8+/-1.2% higher for dosimeters irradiated with neutrons. The dependence of the spectrum amplitude on the microwave power was extensively investigated by fitting observations to an analytical non-linear model incorporating, among others, the spin-lattice (T1) and spin-spin (T2) relaxation times as fitting parameters. Neutron irradiation resulted in a reduction in T(2) in comparison with gamma-irradiation, while a smaller difference in T1 was found. The effects observed indicate increased local radical density following irradiation using high linear energy transfer (LET) neutrons as compared to low LET gamma-irradiation. A fingerprint of the LET may thus be found either by an analysis of the line width or of the dependence of the spectrum amplitude on the microwave power. Lithium formate is therefore a promising material for EPR dosimetry of high LET radiation.

  17. VALIDATION OF HANFORD PERSONNEL AND EXTREMITY DOSIMETERS IN PLUTONIUM ENVIRONMENTS

    SciTech Connect

    Scherpelz, Robert I.; Fix, John J.; Rathbone, Bruce A.

    2000-02-10

    A study was performed in the Plutonium Finishing Plant to assess the performance of Hanford personnel neutron dosimetry. The study was assessed whole body dosimetry and extremity dosimetry performance. For both parts of the study, the TEPC was used as the principle instrument for characterizing workplace neutron fields. In the whole body study, 12.7-cm-diameter TEPCs were used in ten different locations in the facility. TLD and TED personnel dosimeters were exposed on a water-filled phantom to enable a comparison of TEPC and dosimeter response. In the extremity study, 1.27-cm-diameter TEPCs were exposed inside the fingers of a gloveboxe glove. Extremity dosimeters were wrapped around the TEPCs. The glove was then exposed to six different cans of plutonium, simulating the exposure that a worker's fingers would receive in a glovebox. The comparison of TEPC-measured neutron dose equivalent to TLD-measured gamma dose equivalent provided neutron-to-gamma ratios that can be used to estimate the neutron dose equivalent received by a worker's finger based on the gamma readings of an extremity dosimeter. The study also utilized a Snoopy and detectors based on bubble technology for assessing neutron exposures, providing a comparison of the effectiveness of these instruments for workplace monitoring. The study concludes that the TLD component of the HCND performs adequately overall, with a positive bias of 30%, but exhibits excessive variability in individual results due to instabilities in the algorithm. The TED response was less variable but only 20% of the TEPC reference dose on average because of the low neutron energies involved. The neutron response of the HSD was more variable than the TLD component of the HCND and biased high by a factor of 8 overall due to its calibration to unmoderated 252Cf. The study recommends further work to correct instabilities in the HCND algorithm and to explore the potential shown by the bubble-based dosimeters.

  18. Section 9.1 new dosimeters. New dosimetry systems

    NASA Astrophysics Data System (ADS)

    McLaughlin, William L.

    During the past two years there have been significant advances in several forms of radiation measurement systems for radiation processing, covering dose ranges of 1-10 6 Gy. Calorimeters as reference standards for both ionizing photon and electron fields have become well-established. In addition to the older ceric-cerous dosimetry solution analyzed potentiometrically, new liquid-phase dosimeters include those analyzed by spectrophotometry, e.g., improved forms of acidic aqueous solutions of K-Ag dichromate and organic radiochromic dye solutions. It has recently been demonstrated that by using certain refined sugars, e.g., D-(-) ribose, optical rotation response in aqueous solutions can be enhanced for dosimetry at doses > 10 4 Gy. There has been expanded development, use, and formulation (rods, tablets, and thin films) of the amino acid, alanine, as a solid-phase dosimeter analyzed by either ESR spectrometry or by glutamine or alanine spectrophotometry of complexes with ferric ion in the presence of a sulfonphthalein dye (xylenol orange). New commercial types of radiochromic plastic dosimeters, e.g., GafChromic TM, Riso B3 TM, GAMMACHROME YR TM, Radix TM, and Gammex TM, have been introduced and applied in practice. Improvements and broader use of optical waveguide dosimeters, e.g., Opti-Chromic TM, have also been reported, especially in food irradiation applications. Several novel dyed plastic dosimeters are available in large quantities and they lose color due to irradiation. An example is a dyed cellulosic thin film (ATC type DY-42 TM) which can be measured spectrophotometrically or densitometrically up to doses as high as 10 6 Gy.

  19. a Thermally Desorbable Miniature Passive Dosimeter for Organic Vapors

    NASA Astrophysics Data System (ADS)

    Gonzalez, Jesus Antonio

    A thermally desorbable miniature passive dosimeter (MPD) for organic vapors has been developed in conformity with theoretical and practical aspects of passive dosimeter design. The device was optimized for low sample loadings resulting from short-term and/or low concentration level exposure. This was accomplished by the use of thermal desorption rather than solvent elution, which provided the GC method with significantly higher sensitivity. Laboratory evaluation of this device for factors critical to the performance of passive dosimeters using benzene as the test vapor included: desorption efficiency (97.2%), capacity (1400 ppm-min), sensitivity (7ng/sample or 0.06 ppmv for 15 minutes sampling) accuracy and precision, concentration level, environmental conditions (i.e., air face velocity, relative humidity) and sample stability during short (15 minutes) and long periods of time (15 days). This device has demonstrated that its overall accuracy meets NIOSH and OSHA requirements for a sampling and analytical method for the exposure concentration range of 0.1 to 50 ppm (v/v) and 15 minutes exposures. It was demonstrated that the MPD operates in accordance with theoretically predicted performance and should be adequate for short-term and/or low concentration exposure monitoring of organic vapors in the workplace. In addition a dynamic vapor exposure evaluation system for passive dosimeters have been validated using benzene as the test vapor. The system is capable of generating well defined short-square wave concentration profiles suitable for the evaluation of passive dosimeters for ceiling exposure monitoring.

  20. Civil aircraft accident investigation.

    PubMed

    Haines, Daniel

    2013-01-01

    This talk reviews some historic aircraft accidents and some more recent. It reflects on the division of accident causes, considering mechanical failures and aircrew failures, and on aircrew training. Investigation results may lead to improved aircraft design, and to appropriate crew training. PMID:24057309

  1. Anatomy of an Accident.

    ERIC Educational Resources Information Center

    Mobley, Michael

    1984-01-01

    The findings of industrial safety engineers in the areas of accident causation and prevention are wholly applicable to adventure programs. Adventure education instructors can use safety engineering concepts to assess the risk in a particular activity, understand factors that cause accidents, and intervene to minimize injuries and damages if…

  2. Farm accidents in children.

    PubMed Central

    Cameron, D.; Bishop, C.; Sibert, J. R.

    1992-01-01

    OBJECTIVE--To examine the problem of accidental injury to children on farms. DESIGN--Prospective county based study of children presenting to accident and emergency departments over 12 months with injuries sustained in a farm setting and nationwide review of fatal childhood farm accidents over the four years April 1986 to March 1990. SETTING--Accident and emergency departments in Aberystwyth, Carmarthen, Haverfordwest, and Llanelli and fatal accidents in England, Scotland, and Wales notified to the Health and Safety Executive register. SUBJECTS--Children aged under 16. MAIN OUTCOME MEASURE--Death or injury after farm related accidents. RESULTS--65 accidents were recorded, including 18 fractures. Nine accidents necessitated admission to hospital for a mean of two (range one to four) days. 13 incidents were related to tractors and other machinery; 24 were due to falls. None of these incidents were reported under the statutory notification scheme. 33 deaths were notified, eight related to tractors and allied machinery and 10 related to falling objects. CONCLUSIONS--Although safety is improving, the farm remains a dangerous environment for children. Enforcement of existing safety legislation with significant penalties and targeting of safety education will help reduce accident rates further. PMID:1638192

  3. The Pliocene Model Intercomparison Project - Phase 2

    NASA Astrophysics Data System (ADS)

    Haywood, Alan; Dowsett, Harry; Dolan, Aisling; Rowley, David; Abe-Ouchi, Ayako; Otto-Bliesner, Bette; Chandler, Mark; Lunt, Daniel; Salzmann, Ulrich

    2015-04-01

    The Pliocene Model Intercomparison Project (PlioMIP) is a coordinated international climate modelling initiative designed to understand climate and environments of the Late Pliocene, and their potential relevance in the context of future climate change. PlioMIP operates under the umbrella of the Palaeoclimate Modelling Intercomparison Project (PMIP), which examines multiple intervals in Earth history, the consistency of model predictions in simulating these intervals and their ability to reproduce climate signals preserved in geological climate archives. PlioMIP was initiated in 2008 and is closely aligned with the U.S. Geological Survey project known as PRISM (Pliocene Research Interpretation and Synoptic Mapping). PRISM has spent more than 25 years reconstructing and understanding mid-Pliocene climate (~3.3 to 3 million years ago), as well producing boundary condition data sets suitable for use with numerical climate models. The first phase of the PlioMIP (PlioMIP1: 2008-2014) resulted in the most complete analysis to date of the Pliocene climate. This included examination of large-scale features of global climate, detailed analyses of Pliocene ocean circulation and monsoon behaviour, and the ability of models to reproduce regional climate patterns reconstructed from both marine and terrestrial archives. The lessons learned from PlioMIP1 facilitated a revision of data and modelling approaches towards the understanding of the mid Pliocene. PlioMIP2 has now been launched, and includes significant improvements to many of the Pliocene palaeogeograhic boundary conditions used for driving climate models (new land/sea mask, topography, bathymetry and ice sheet reconstructions). Within Phase 2 modelling groups have the option of using dynamic global vegetation models to predict (rather than prescribe) land cover, and a broader portfolio of model experiments has been proposed to support efforts to better understand the Pliocene, as well as to use the Pliocene as a means

  4. A proposed four-element neutron-photon-beta thermoluminescence dosimeter.

    PubMed

    Liu, J C; Sims, C S; Ahmed, A B

    1992-09-01

    It is common practice for a worker exposed to a mixed field with neutrons to wear both a photon-beta dosimeter and a neutron dosimeter. In this study, a thermoluminescence dosimeter has been designed and is proposed for use in mixed fields. The maximum applicable ranges of the mixed field can have photons with unknown energy from 20 keV to 2 MeV, betas with unknown energy from 147Pm to 90Sr-Y, and neutrons of known energy from thermal to 15 MeV. This proposed dosimeter (a combination of Harshaw beta-gamma thermoluminescence dosimeter and albedo neutron thermoluminescence dosimeter) has an advantage of using a minimum number of thermoluminescence dosimeter elements (therefore, making it less costly) to measure the dose equivalents in a mixed field of neutron, photon, and beta radiation. The basic dosimeter design consists of four thermoluminescence elements of TLD-600 and TLD-700 with different filtrations. Using the high-temperature peak methodology for TLD-600 and a filtration algorithm, the neutron, photon, and beta dose equivalents in a mixed field can be determined. The design, detection principle, and three dosimetric algorithms for three versions of the basic design of the four-element dosimeter are presented and discussed. The work that is required for the proposed dosimeter to be usable when it is made is also presented. PMID:1644568

  5. Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF:Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology.

    PubMed

    Dong, S L; Chu, T C; Lan, G Y; Wu, T H; Lin, Y C; Lee, J S

    2002-12-01

    Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3% at tube potentials from 40Vp to 125kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures.

  6. Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF:Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology.

    PubMed

    Dong, S L; Chu, T C; Lan, G Y; Wu, T H; Lin, Y C; Lee, J S

    2002-12-01

    Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3% at tube potentials from 40Vp to 125kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures. PMID:12406633

  7. [Measurement of the Dose Rate Using Dosimeters in Interventional Radiology and Its Difficulty].

    PubMed

    Yoshida, Hidenori; Takahashi, Chiharu; Narita, Nobuhiro; Mizusawa, Yasuhiko; Sekiya, Masaru; Ohkubo, Masaki

    2016-01-01

    In equipment used for interventional radiology (IVR), automatic exposure control (AEC) is incorporated to obtain the X-ray output suitable for the treatment of targeted lesions. For the AEC, users select a region as the signal sensing region (measuring field, MF) in the flat panel detector; MFs with various sizes and shapes were pre-defined and prepared in the system. The aim of this study was to examine the change of measured dose rate with the selection of MFs, the type of dosimeters (the ionization chamber dosimeter and the semiconductor dosimeter), and the dosimeter placement relative to the direction of X-ray tube (from cathode to anode). The IVR equipment was Allura Xper FD20/10 (Philips Medical Systems), and six kinds of built-in MFs were used. It was found that dose rate measured by the ionization chamber dosimeter showed a variation of -2 mGy/min with the MFs and the ionization chamber dosimeter placement. The dose rate measured by the semiconductor dosimeter showed more variation than the ionization chamber dosimeter. The change of dose rate with the dosimeter placement would be caused by the MF overlapping the dosimeter which would affect the AEC (the X-ray output). Also, the change of dose rate with the dosimeter placement was considered to be related to the heel effect of the X-ray beam. When performing dose rate measurements, we should notice that the selection of MFs, the type of dosimeters, and the dosimeter placement would affect the measured values. PMID:26796935

  8. Marine tropospheric hydrocarbons: An intercomparison exercise

    NASA Astrophysics Data System (ADS)

    Carsey, Thomas P.

    1991-07-01

    Results from an multilaboratory intercomparison exercise for the determination of non-methane hydrocarbons in the North Pacific troposphere are presented. Each of the ten participating labs analyzed marine air obtained on the NOAA ship R/V RESEARCHER and from a single large tank of Oregon coastal air for some or all of the following: ethane, ethylene, 1-butene, isobutene (2-methyl 1-propene), cis-2-butene, trans-2-butene, iso-pentene, n-pentane, isopentene (2-methyl 1-butene), 1-pentene, benzene, toluene, methane, carbon dioxide, and methyl chloroform. The following parameters were computed where data was sufficient for each lab and each analyte: mean mixing ratios, total precision, analytical precision, and sampling precision. Means were compared using a nonparametric procedure. Mixing ratios vs time data for the various compounds indicated that diurnal changes were minimal or absent; however, slight decreases in mixing ratios were observed for C2H6, C2H2, CH3CCl3, CO and CH4.

  9. Intercomparisons of nine sky brightness detectors.

    PubMed

    den Outer, Peter; Lolkema, Dorien; Haaima, Marty; van der Hoff, Rene; Spoelstra, Henk; Schmidt, Wim

    2011-01-01

    Nine Sky Quality Meters (SQMs) have been intercompared during a night time measurement campaign held in the Netherlands in April 2011. Since then the nine SQMs have been distributed across The Netherlands and form the Dutch network for monitoring night sky brightness. The goal of the intercomparison was to infer mutual calibration factors and obtain insight into the variability of the SQMs under different meteorological situations. An ensemble average is built from the individual measurements and used as a reference to infer the mutual calibration factors. Data required additional synchronization prior to the calibration determination, because the effect of moving clouds combined with small misalignments emerges as time jitter in the measurements. Initial scatter of the individual instruments lies between ±14%. Individual night time sums range from -16% to +20%. Intercalibration reduces this to 0.5%, and -7% to +9%, respectively. During the campaign the smallest luminance measured was 0.657 ± 0.003 mcd/m(2) on 12 April, and the largest value was 5.94 ± 0.03 mcd/m(2) on 2 April. During both occurrences interfering circumstances like snow cover or moonlight were absent.

  10. Intercomparison of land-surface parameterizations launched

    NASA Astrophysics Data System (ADS)

    Henderson-Sellers, A.; Dickinson, R. E.

    One of the crucial tasks for climatic and hydrological scientists over the next several years will be validating land surface process parameterizations used in climate models. There is not, necessarily, a unique set of parameters to be used. Different scientists will want to attempt to capture processes through various methods “for example, Avissar and Verstraete, 1990”. Validation of some aspects of the available (and proposed) schemes' performance is clearly required. It would also be valuable to compare the behavior of the existing schemes [for example, Dickinson et al., 1991; Henderson-Sellers, 1992a].The WMO-CAS Working Group on Numerical Experimentation (WGNE) and the Science Panel of the GEWEX Continental-Scale International Project (GCIP) [for example, Chahine, 1992] have agreed to launch the joint WGNE/GCIP Project for Intercomparison of Land-Surface Parameterization Schemes (PILPS). The principal goal of this project is to achieve greater understanding of the capabilities and potential applications of existing and new land-surface schemes in atmospheric models. It is not anticipated that a single “best” scheme will emerge. Rather, the aim is to explore alternative models in ways compatible with their authors' or exploiters' goals and to increase understanding of the characteristics of these models in the scientific community.

  11. Intercomparison of global burned area products

    NASA Astrophysics Data System (ADS)

    Chuvieco, E.; Corti, D.; Padilla, M.

    2012-12-01

    The European Space Agency's Climate Change Initiative (CCI) is part of the European contribution to the Global Observing Climate System (GCOS) program. Fire disturbance is one of the Essential Climate Variables included in this phase of the CCI program. The project aims to map globally burned areas (BA) using European sensors (ATSR, VEGETATION and MERIS), and in comparing the performance of the results with other existing datasets (www.esa-fire-cci.org). The project aims at developing and validating algorithms, to produce consistent, stable, error-characterized global BA information. It includes as well algorithms for pre-processing of ATSR, VEGETATION and MERIS data, to improve geometrical accuracy and remove atmospheric effects that may lead to potential confusions with burned areas (clouds, smoke, cloud shadows, water, snow, topographic shadows), as well as algorithms to merge BA from different sensors and adapting the outputs to the needs of the climate modeling community. This paper will present the latest comparisons of the fire_cci BA results with other existing global BA products, using a validation dataset of 100 Landsat multitemporal pairs, from which fire perimeters were semi-automatically drawn. The standard CEOS Cal-Val procedures have been used to document the reference files. The intercomparison method relies on measuring accuracy, error balance and temporal consistency. Preliminary results showed higher accuracy for MCD45, but with lower temporal consistency, particularly in areas dominated by savannah fires.

  12. Intercomparison of aerosol instruments: number concentration

    SciTech Connect

    Knutson, E O; Sinclair, D; Tu, K W; Hinchliffe, L; Franklin, H

    1982-05-01

    An intercomparison of aerosol instruments conducted February 23-27, 1981, at the Environmental Measurements Laboratory (EML) focused on five instruments: the Pollak and TSI condensation nucleus counters; the Active Scattering Aerosol Spectrometer (ASAS-X); and two aerosol electrometers. Test aerosols of sodium chloride and ammonium fluorescein generated by nebulization/electrostatic classification were used to obtain 195 lines of comparison data. Concentrations measured by the ASAS-X and the TSI aerosol electrometer averaged respectively 1.388 and 1.581 times that measured by the Pollak. These ratios were very stable during the week and there was little effect of particle size or material. Most other comparisons were equally stable. However, a review of past work at EML and elsewhere led to the disturbing conclusion that these ratios may change from year to year, or from season to season. A filter sample was taken from microscopy, concurrent with readings from the ASAS-X and the TSI condensation nucleus counters. In this sample, the two instruments differed by 20%. Within its 20% uncertainty, the filter result matched both the TSI and ASAS-X readings.

  13. Strontium sulfate as an EPR dosimeter for radiation technology application

    NASA Astrophysics Data System (ADS)

    Rushdi, M. A. H.; Abdel-Fattah, A. A.; Sherif, M. M.; Soliman, Y. S.; Mansour, A.

    2015-01-01

    The dosimetric characteristics of γ-radiation induced defects in strontium sulfate rod dosimeter are investigated using electron paramagnetic resonance (EPR) technique focusing on the low dose range of 1-100 Gy. Significant EPR signals of spectroscopic splitting factor (g) 2.01075, 2.04225, 2.03166, 2.00774 and 1.9219086 are observed in the rod upon γ-irradiation. The intensity of the signals increases linearly with increasing absorbed doses up to 100 Gy. The EPR response of irradiated dosimeter exhibits good stability over three months of storage. In addition, the response during irradiation is independent on both relative humidity (from 0% to 65%) and temperature (from 10 °C to 35 °C). The prepared rods are nearly water equivalent in the range of 0.4-5 MeV and the overall uncertainty (2σ) of dose monitoring is approximately 4.26%.

  14. A genipin-gelatin gel dosimeter for radiation processing

    NASA Astrophysics Data System (ADS)

    Davies, J. B.; Bosi, S. G.; Baldock, C.

    2012-08-01

    Genipin, a fruit extract from Gardenia jasminoides Ellis, forms cross-links in solutions of gelatin, to form a blue hydrogel that bleaches quantitatively upon irradiation and the colour change can be measured with a spectrophotometer. With the addition of sulphuric acid this dosimeter is sufficiently sensitive for quality assurance of radiotherapy level dosimetry. Without sulphuric acid the gel has a reduced sensitivity and responds linearly with dose between 100 and 1000 Gy, making it potentially useful as a dosimeter for radiation processing applications such as the phytosanitary irradiation treatment of food. We investigated the dose response characteristics of this new formulation and found that the darker gels are more sensitive to dose and have a reduced uncertainty.

  15. A new electronic neutron dosimeter (END) for reliable personal dosimetry

    NASA Astrophysics Data System (ADS)

    Ing, H.; Cousins, T.; Andrews, H. R.; Machrafi, R.; Voevodskiy, A.; Kovaltchouk, V.; Clifford, E. T. H.; Robins, M.; Larsson, C.; Hugron, R.; Brown, J.

    2008-04-01

    Tests of existing electronic neutron dosimeters by military and civilian groups have revealed significant performance limitations. To meet the operational requirements of emergency response personnel to a radiological/nuclear incident as well as those in the nuclear industry, a new END has been developed. It is patterned after a unique commercial neutron spectral dosemeter known as the N-probe. It uses a pair of small special scintillators on tiny photomultiplier tubes. Special electronics were designed to minimize power consumption to allow for weeks of operation on a single charge. The size, performance, and data analysis for the END have been designed to meet/exceed international standards for electronic neutron dosimeters. Results obtained with the END prototype are presented.

  16. Laser CT evaluation on normoxic PAGAT gel dosimeter

    NASA Astrophysics Data System (ADS)

    Kumar, D. S.; Samuel, E. J. J.; Watanabe, Y.

    2013-06-01

    Optical computed tomography has been shown to be a potentially useful imaging tool for the radiation therapy physicists. In radiation therapy, researchers have used optical CT for the readout of 3D dosimeters. The purpose of this paper is to describe the initial evaluation of a newly fabricated laser CT scanner for 3D gel dosimetry which works using the first generation principle. A normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When a laser passes through the gel phantom, absorption and scattering of photon take place. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by a sensor. The scanner motion is controlled by a computer program written in Microsoft Visual C++. Reconstruction and data analysis on the irradiated gel phantom is performed by suitable algorithm using Matlab software.

  17. An optical dosimeter for monitoring heavy metal ions in water

    NASA Astrophysics Data System (ADS)

    Mignani, Anna G.; Regan, Fiona; Leamy, D.; Mencaglia, A. A.; Ciaccheri, L.

    2005-05-01

    This work presents an optochemical dosimeter for determining and discriminating nickel, copper, and cobalt ions in water that can be used as an early warning system for water pollution. An inexpensive fiber optic spectrophotometer monitors the sensor's spectral behavior under exposure to water solutions of heavy metal ions in the 1-10 mg/l concentration range. The Principal Component Analysis (PCA) method quantitatively determines the heavy metals and discriminates their type and combination.

  18. Low-cost commercial glass beads as dosimeters in radiotherapy

    NASA Astrophysics Data System (ADS)

    Jafari, S. M.; Bradley, D. A.; Gouldstone, C. A.; Sharpe, P. H. G.; Alalawi, A.; Jordan, T. J.; Clark, C. H.; Nisbet, A.; Spyrou, N. M.

    2014-04-01

    Recent developments in advanced radiotherapy techniques using small field photon beams, require small detectors to determine the delivered dose in steep dose gradient fields. Commercially available glass jewellery beads exhibit thermoluminescent properties and have the potential to be used as dosimeters in radiotherapy due to their small size (<5 mm), low cost, reusability and inert nature. This study investigated the dosimetric characteristics of glass beads. The beads were irradiated by 6 MV photons using a medical linear-accelerator and 60Co gamma rays over doses ranging from 1 to 2500 cGy. A thermoluminescence (TL) system and an electron paramagnetic resonance (EPR) system were employed for read out. Both the TL and EPR studies demonstrated a radiation-induced signal, the sensitivity of which varied with bead colour. White coloured beads proved to be the most sensitive for both systems. The smallest and therefore least sensitive bead sizes allowed measurement of doses of 1 cGy using the TL system while that for the EPR system was approximately 1000 cGy. The fading rate was found to be 10% 30 days after irradiation with both readout systems. The dose response is linear with measured dose over the dose range 1 to 2500 cGy, with an R2 correlation coefficient of greater than 0.999. The batch-to-batch reproducibility of a set of dosimeters after a single irradiation was found to be 3% (1 SD). The reproducibility of individual dosimeters was found to be 1.7%. No measurable angular dependence was found (results agreed within 1%). Dose rate response was found to agree within 1% for dose rates of 100 to 600 cGy/min. These results demonstrate the potential use of glass beads as TL dosimeters over the dose range commonly applied in radiotherapy.

  19. Persistence of airline accidents.

    PubMed

    Barros, Carlos Pestana; Faria, Joao Ricardo; Gil-Alana, Luis Alberiko

    2010-10-01

    This paper expands on air travel accident research by examining the relationship between air travel accidents and airline traffic or volume in the period from 1927-2006. The theoretical model is based on a representative airline company that aims to maximise its profits, and it utilises a fractional integration approach in order to determine whether there is a persistent pattern over time with respect to air accidents and air traffic. Furthermore, the paper analyses how airline accidents are related to traffic using a fractional cointegration approach. It finds that airline accidents are persistent and that a (non-stationary) fractional cointegration relationship exists between total airline accidents and airline passengers, airline miles and airline revenues, with shocks that affect the long-run equilibrium disappearing in the very long term. Moreover, this relation is negative, which might be due to the fact that air travel is becoming safer and there is greater competition in the airline industry. Policy implications are derived for countering accident events, based on competition and regulation.

  20. RESULTS FROM THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    A North American Mercury Model Intercomparison Study (NAMMIS) has been conducted to build upon the findings from previous mercury model intercomparison in Europe. In the absence of mercury measurement networks sufficient for model evaluation, model developers continue to rely on...

  1. Characterization and application of two kinds of ESR dosimeters

    NASA Astrophysics Data System (ADS)

    Marchioni, Eric; Pabst, Jean-Yves; Kuntz, Florent

    2002-09-01

    Many previous papers described the use of low-concentration alanine pellets, powder or films for industrial high-dose application, but very few authors presented applications of such dosimeters to the low-dose range used for wastewater, flowers or radiotherapy treatment. The present paper describes the large-scale manufacturing process of high-concentration alanine pellets used for radiotherapy dose control in some French hospitals. The fading process due to sunlight exposure has been evaluated by means of direct UV light irradiation. The major disadvantage of alanine is its strong solubility in water (the pellets are completely dissolved when immersed for 10 min in pure water). The use of barium sulphate, not soluble in water, made it possible to carry out dosimetric measurements even when the dosimeter is completely immersed in water or stored after irradiation in high humidity levels. The paper presents manufacturing process of barium sulphate pellets, their dosimetric characteristics and one application of this dosimeter for the control of the absorbed doses during wastewater treatments.

  2. Response of ionization chamber based pocket dosimeter to beta radiation.

    PubMed

    Kumar, Munish; Gupta, Anil; Pradhan, S M; Bakshi, A K; Chougaonkar, M P; Babu, D A R

    2013-12-01

    Quantitative estimate of the response of ionization chamber based pocket dosimeters (DRDs) to various beta sources was performed. It has been established that the ionization chamber based pocket dosimeters do not respond to beta particles having energy (Emax)<1 MeV and same was verified using (147)Pm, (85)Kr and (204)Tl beta sources. However, for beta particles having energy >1 MeV, the DRDs exhibit measureable response and the values are ~8%, ~14% and ~27% per mSv for natural uranium, (90)Sr/(90)Y and (106)Ru/(106)Rh beta sources respectively. As the energy of the beta particles increases, the response also increases. The response of DRDs to beta particles having energy>1 MeV arises due to the fact that the thickness of the chamber walls is less than the maximum range of beta particles. This may also be one of the reasons for disparity between doses measured with passive/legal dosimeters (TLDs) and DRDs in those situations in which radiation workers are exposed to mixed field of gamma photons and beta particles especially at uranium processing plants, nuclear (power and research) reactors, waste management facilities and fuel reprocessing plants etc. The paper provides the reason (technical) for disparity between the doses recorded by TLDs and DRDs in mixed field of photons and beta particles.

  3. Real-time dosimeter targeted to nuclear applications

    NASA Astrophysics Data System (ADS)

    Correia, Alexandre; Rosa, Carla C.; Santos, Pedro M. P.; Falcão, António N.; Lorentz, Katharina

    2014-08-01

    An intrinsic fiber optic dosimeter (FOD) targeted to nuclear applications is presented. The proposed real-time dosimeter provides dose information based on the historic record over time of the effects of ionizing radiation on single- and multimode pure silica fibers, and also on PMMA plastic fibers. The effect of 60Co gamma irradiation on optical links based on silica and plastic fibers were assessed, considering thermal environment effects over a wide range of variation of the operating parameters. Cerenkov radiation and radiation-induced absorption effects were in focus. The corresponding distortion and spectral transmission degradation were evaluated over wide range of the operating parameters. Radiation induced attenuation (RIA) has shown a spectral band dependent behaviour up to 840 Gy dose levels. The performance of different fibers was assessed against the performance of non-irradiated fibers. From the measurements of dose rate and total dose imparted by ionizing radiation in the fibers we verified that fibers with radiation resistance issues showed wavelength-dependent radiation sensitivity increasing with dose rate. Upon evaluation of correlations between the total dose, the induced loss at various dose rates and different wavelengths, it was concluded that intrinsic fiber dosimeters can be used for dose rates in the range 4 - 28 Gy/min., typical of severe radiation environments.

  4. Response of Panasonic dosimeters to submersion exposure by 133Xe.

    PubMed

    Hoffman, J M; Catchen, G L

    1990-01-01

    The dose response to 133Xe radiation of several types of Panasonic 800 series thermoluminescent dosimeters (TLD) were evaluated. The dosimeters were exposed by submersion in 133Xe gas. The relative sensitivities of the lithium borate and the calcium sulfate phosphors were determined for several configurations. The TLDs were exposed in the holders (as the devices came from the vendor) with various shields covering the elements, and they were exposed with the TLDs removed from the holders. Some dosimeters were exposed, both in holders and out of holders (TL insert only configuration), both in plastic bags and free in air. For the in-holder configuration, the responses of the heavily shielded (greater than 170 mg cm-2) elements were used to obtain the photon dose-rate component, and the responses of the lightly shielded (less than 13 mg cm-2) element were used to obtain the beta component. Similarly, for the insert-only configurations, the observed over-response of the calcium sulfate phosphors to low-energy photons could be used to separate the beta dose rate component. By using the calculated beta doses, correction factors were determined for the apparent under-responses of the elements to beta radiation. The results of both methods are consistent. These results also suggest that the beta component could be used in environmental monitoring as a more sensitive means to determine 133Xe activities in clouds and to separate some of the effects of submersion exposure from those of distant exposure.

  5. A new 2 methylalanine-PVC ESR dosimeter.

    PubMed

    Rossi, Bruno T; Chen, Felipe; Baffa, Oswaldo

    2005-02-01

    The use of polyvinyl chloride (PVC) as a binder to 2-methylalanine (2MA) dosimeters was investigated. It was recently shown by Olsson et al. (Radiat. Res. 157 (2002) 113), that 2MA is approximately 70% more sensitive than L-alanine which makes this substance a good candidate to replace alanine in ESR dosimetry. PVC is a low yield material for free radical production by ionizing radiation and a good binding material easily processed and widely available. PVC can be prepared at room temperature and mixed up to 50% in weight with 2MA to produce a pellet stable in mass and physical dimensions, in large quantities and with low background signal. Pure PVC pellet irradiated at 50 Gy gave weaker ESR signals compared to 2MA at the region of spectral interest. Spectrometer settings such as microwave power, and modulation amplitude were optimized for the measurements. This dosimeter production scheme allows the addition of Mn2+ ions for an internal reference signal, leading to a self-calibrated dosimeter (J. Radional. Nucl. Chem. 240 (1999) 215).

  6. Method for preparing dosimeter for measuring skin dose

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1982-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with neutron-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  7. Dosimeter for measuring skin dose and more deeply penetrating radiation

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1981-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with netruon-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  8. Optimizing the sensitivity and radiological properties of the PRESAGE® dosimeter using metal compounds

    NASA Astrophysics Data System (ADS)

    Alqathami, Mamdooh; Blencowe, Anton; Qiao, Greg; Adamovics, John; Geso, Moshi

    2012-11-01

    The aim of this study is to investigate the radiation-modifying effects of incorporating commercially available bismuth-, tin- and zinc-based compounds in the composition of the PRESAGE® dosimeter, and the feasibility of employing such compounds for radiation dose enhancement. Furthermore, we demonstrate that metal compounds can be included in the formulation to yield water-equivalent PRESAGE® dosimeters with enhanced dose response. Various concentrations of the metal compounds were added to a newly developed PRESAGE® formulation and the resulting dosimeters were irradiated with 100 kV and 6 MV photon beams. A comparison between sensitivity and radiological properties of the PRESAGE® dosimeters with and without the addition of metal compounds was carried out. Optical density changes of the dosimeters before and after irradiation were measured using a spectrophotometer. In general, when metal compounds were incorporated in the composition of the PRESAGE® dosimeter, the sensitivity of the dosimeters to radiation dose increased depending on the type and concentration of the metal compound, with the bismuth compound showing the highest dose enhancement factor. In addition, these metal compounds were also shown to improve the retention of the post-response absorption value of the PRESAGE® dosimeter over a period of 2 weeks. Thus, incorporating 1-3 mM (ca. 0.2 wt%) of any of the three investigated metal compounds in the composition of the PRESAGE® dosimeter is found to be an efficient way to enhance the sensitivity of the dosimeter to radiation dose and stabilize its post-response for longer times. Furthermore, the addition of small amounts of the metal compounds also accelerates the polymerization of the PRESAGE® dosimeter precursors, significantly reducing the fabrication time. Finally, a novel water-equivalent PRESAGE® dosimeter formula optimized with metal compounds is proposed for clinical use in both kilovoltage and megavoltage radiotherapy dosimetry.

  9. The Assessment of Effective Dose Equivalent Using Personnel Dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Xie

    From January 1994, U.S. nuclear plants must develop a technically rigorous approach for determining the effective dose equivalent for their work forces. This dissertation explains concepts associated with effective dose equivalent and describes how to assess effective dose equivalent by using conventional personnel dosimetry measurements. A Monte Carlo computer code, MCNP, was used to calculate photon transport through a model of the human body. Published mathematical phantoms of the human adult male and female were used to simulate irradiation from a variety of external radiation sources in order to calculate organ and tissue doses, as well as effective dose equivalent using weighting factors from ICRP Publication 26. The radiation sources considered were broad parallel photon beams incident on the body from 91 different angles and isotropic point sources located at 234 different locations in contact with or near the body. Monoenergetic photons of 0.08, 0.3, and 1.0 MeV were considered for both sources. Personnel dosimeters were simulated on the surface of the body and exposed to with the same sources. From these data, the influence of dosimeter position on dosimeter response was investigated. Different algorithms for assessing effective dose equivalent from personnel dosimeter responses were proposed and evaluated. The results indicate that the current single-badge approach is satisfactory for most common exposure situations encountered in nuclear plants, but additional conversion factors may be used when more accurate results become desirable. For uncommon exposures involving source situated at the back of the body or source located overhead, the current approach of using multi-badges and assigning the highest dose is overly conservative and unnecessarily expensive. For these uncommon exposures, a new algorithm, based on two dosimeters, one on the front of the body and another one on the back of the body, has been shown to yield conservative assessment of

  10. Investigation of radiological properties and water equivalency of PRESAGE dosimeters

    SciTech Connect

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Adamovics, John; Bosi, Stephen; Kim, Jung-Ha; Baldock, Clive

    2011-04-15

    Purpose: PRESAGE is a dosimeter made of polyurethane, which is suitable for 3D dosimetry in modern radiation treatment techniques. Since an ideal dosimeter is radiologically water equivalent, the authors investigated water equivalency and the radiological properties of three different PRESAGE formulations that differ primarily in their elemental compositions. Two of the formulations are new and have lower halogen content than the original formulation. Methods: The radiological water equivalence was assessed by comparing the densities, interaction probabilities, and radiation dosimetry properties of the three different PRESAGE formulations to the corresponding values for water. The relative depth doses were calculated using Monte Carlo methods for 50, 100, 200, and 350 kVp and 6 MV x-ray beams. Results: The mass densities of the three PRESAGE formulations varied from 5.3% higher than that of water to as much as 10% higher than that of water for the original formulation. The probability of photoelectric absorption in the three different PRESAGE formulations varied from 2.2 times greater than that of water for the new formulations to 3.5 times greater than that of water for the original formulation. The mass attenuation coefficient for the three formulations is 12%-50% higher than the value for water. These differences occur over an energy range (10-100 keV) in which the photoelectric effect is the dominant interaction. The collision mass stopping powers of the relatively lower halogen-containing PRESAGE formulations also exhibit marginally better water equivalency than the original higher halogen-containing PRESAGE formulation. Furthermore, the depth dose curves for the lower halogen-containing PRESAGE formulations are slightly closer to that of water for a 6 MV beam. In the kilovoltage energy range, the depth dose curves for the lower halogen-containing PRESAGE formulations are in better agreement with water than the original PRESAGE formulation. Conclusions: Based

  11. Accident resistant transport container

    DOEpatents

    Anderson, J.A.; Cole, K.K.

    The invention relates to a container for the safe air transport of plutonium having several intermediate wood layers and a load spreader intermediate an inner container and an outer shell for mitigation of shock during a hypothetical accident.

  12. Accident resistant transport container

    DOEpatents

    Andersen, John A.; Cole, James K.

    1980-01-01

    The invention relates to a container for the safe air transport of plutonium having several intermediate wood layers and a load spreader intermediate an inner container and an outer shell for mitigation of shock during a hypothetical accident.

  13. Safety Is No Accident.

    ERIC Educational Resources Information Center

    Christiansen, Monty L.

    1985-01-01

    Liability suits involving accidents in park and recreation areas are expensive and intangible costs are incalculable. Risk management practices related to park planning, personnel, and administrative practices are discussed. (MT)

  14. Ozone differential absorption lidar algorithm intercomparison.

    PubMed

    Godin, S; Carswell, A I; Donovan, D P; Claude, H; Steinbrecht, W; McDermid, I S; McGee, T J; Gross, M R; Nakane, H; Swart, D P; Bergwerff, H B; Uchino, O; von der Gathen, P; Neuber, R

    1999-10-20

    An intercomparison of ozone differential absorption lidar algorithms was performed in 1996 within the framework of the Network for the Detection of Stratospheric Changes (NDSC) lidar working group. The objective of this research was mainly to test the differentiating techniques used by the various lidar teams involved in the NDSC for the calculation of the ozone number density from the lidar signals. The exercise consisted of processing synthetic lidar signals computed from simple Rayleigh scattering and three initial ozone profiles. Two of these profiles contained perturbations in the low and the high stratosphere to test the vertical resolution of the various algorithms. For the unperturbed profiles the results of the simulations show the correct behavior of the lidar processing methods in the low and the middle stratosphere with biases of less than 1% with respect to the initial profile to as high as 30 km in most cases. In the upper stratosphere, significant biases reaching 10% at 45 km for most of the algorithms are obtained. This bias is due to the decrease in the signal-to-noise ratio with altitude, which makes it necessary to increase the number of points of the derivative low-pass filter used for data processing. As a consequence the response of the various retrieval algorithms to perturbations in the ozone profile is much better in the lower stratosphere than in the higher range. These results show the necessity of limiting the vertical smoothing in the ozone lidar retrieval algorithm and questions the ability of current lidar systems to detect long-term ozone trends above 40 km. Otherwise the simulations show in general a correct estimation of the ozone profile random error and, as shown by the tests involving the perturbed ozone profiles, some inconsistency in the estimation of the vertical resolution among the lidar teams involved in this experiment.

  15. Tenth ORNL Personnel Dosimetry Intercomparison Study

    SciTech Connect

    Swaja, R.E.; Chou, T.L.; Sims, C.S.; Greene, R.T.

    1985-03-01

    The Tenth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory during April 9-11, 1984. Dosemeter badges from 31 participating organizations were mounted on 40cm Lucite phantoms and exposed to a range of dose equivalents which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor served as the only source of radiation for eight of the ten irradiations which included a low (approx. 0.50 mSv) and high (approx. 10.00 mSv) neutron dose equivalent run for each of four shield conditions. Two irradiations were also conducted for which concrete- and Lucite-shield reactor irradiations were gamma-enhanced using a /sup 137/Cs source. Results indicated that some participants had difficulty obtaining measurable indication of neutron and gamma exposures at dose equivalents less than about 0.50 mSv and 0.20 mSv, respectively. Albedo dosemeters provided the best overall accuracy and precision for the neutron measurements. Direct interaction TLD systems showed significant variation in accuracy with incident spectrum, and threshold neutron dosemeters (film and recoil track) underestimated reference values by more than 50%. Gamma dose equivalents estimated in the mixed fields were higher than reference values with TL gamma dosemeters generally yielding more accurate results than film. Under the conditions of this study in which participants had information concerning exposure conditions and radiation field characteristics prior to dosemeter evaluation, only slightly more than half of all reported results met regulatory standards for neutron and gamma accuracy. 19 refs., 2 figs., 29 tabs.

  16. ISMIP6: Ice Sheet Model Intercomparison Project for CMIP6

    NASA Technical Reports Server (NTRS)

    Nowicki, S.

    2015-01-01

    ISMIP6 (Ice Sheet Model Intercomparison Project for CMIP6) targets the Cryosphere in a Changing Climate and the Future Sea Level Grand Challenges of the WCRP (World Climate Research Program). Primary goal is to provide future sea level contribution from the Greenland and Antarctic ice sheets, along with associated uncertainty. Secondary goal is to investigate feedback due to dynamic ice sheet models. Experiment design uses and augment the existing CMIP6 (Coupled Model Intercomparison Project Phase 6) DECK (Diagnosis, Evaluation, and Characterization of Klima) experiments. Additonal MIP (Model Intercomparison Project)- specific experiments will be designed for ISM (Ice Sheet Model). Effort builds on the Ice2sea, SeaRISE (Sea-level Response to Ice Sheet Evolution) and COMBINE (Comprehensive Modelling of the Earth System for Better Climate Prediction and Projection) efforts.

  17. Scintillation dosimeter arrays using air core light guides: simulation and experiment.

    PubMed

    Naseri, Pourandokht; Suchowerska, Natalka; McKenzie, David R

    2010-06-21

    The performance of a scintillation dosimeter that uses a silvered air core light guide is examined by Monte Carlo (MC) simulations and by experiment to determine its suitability for array dosimetry in external beam radiotherapy. The air core light guide avoids the generation of the Cerenkov background that is produced in a conventional optical fibre. MC simulations using a 6 MV photon beam showed that silver thicknesses of less than 1 microm compensated for the effects of the other material components, to give the dosimeter water equivalence within 0.5%. A second dosimeter located adjacent to the primary dosimeter in any direction affected the dose measurement by less than 1.5%, when the centre-to-centre spacing was 1.3 mm or greater. When the dosimeter array is located perpendicular to the beam central axis, with a spacing of 2.5 mm, the calculated deviation from the dose deposited in water was less than 2%. When the dosimeter array is located parallel to the beam central axis with a spacing of 10 mm, the calculated dose readings deviated from water by less than 2.5%. The simulation results were confirmed with experiment for two neighbouring dosimeters and a small densely packed array. No proximity effects were measured within the experimental error of +/-1.5%. These results confirm the dosimetric accuracy of the air core dosimeter design without the need for correction factors. The dosimeter has excellent potential for use in arrays.

  18. Accident management information needs

    SciTech Connect

    Hanson, D.J.; Ward, L.W.; Nelson, W.R.; Meyer, O.R. )

    1990-04-01

    In support of the US Nuclear Regulatory Commission (NRC) Accident Management Research Program, a methodology has been developed for identifying the plant information needs necessary for personnel involved in the management of an accident to diagnose that an accident is in progress, select and implement strategies to prevent or mitigate the accident, and monitor the effectiveness of these strategies. This report describes the methodology and presents an application of this methodology to a Pressurized Water Reactor (PWR) with a large dry containment. A risk-important severe accident sequence for a PWR is used to examine the capability of the existing measurements to supply the necessary information. The method includes an assessment of the effects of the sequence on the measurement availability including the effects of environmental conditions. The information needs and capabilities identified using this approach are also intended to form the basis for more comprehensive information needs assessment performed during the analyses and development of specific strategies for use in accident management prevention and mitigation. 3 refs., 16 figs., 7 tabs.

  19. Contribution towards statistical intercomparison of general circulation models

    SciTech Connect

    Sengupta, S.; Boyle, J.

    1995-06-01

    The Atmospheric Model Intercomparison Project (AMIP) of the World Climate Research Programme`s Working Group on Numerical Experimentation (WGNE) is an ambitious attempt to comprehensively intercompare atmospheric General Circulation Models (GCMs). The participants in AMIP simulate the global atmosphere for the decade 1979 to 1988 using, a common solar constant and Carbon Dioxide(CO{sub 2}) concentration and a common monthly averaged sea surface temperature (SST) and sea ice data set. In this work we attempt to present a statistical framework to address the difficult task of model intercomparison and verification.

  20. Environmental radioactive intercomparison program and radioactive standards program

    SciTech Connect

    Dilbeck, G.

    1993-12-31

    The Environmental Radioactivity Intercomparison Program described herein provides quality assurance support for laboratories involved in analyzing public drinking water under the Safe Drinking Water Act (SDWA) Regulations, and to the environmental radiation monitoring activities of various agencies. More than 300 federal and state nuclear facilities and private laboratories participate in some phase of the program. This presentation describes the Intercomparison Program studies and matrices involved, summarizes the precision and accuracy requirements of various radioactive analytes, and describes the traceability determinations involved with radioactive calibration standards distributed to the participants. A summary of program participants, sample and report distributions, and additional responsibilities of this program are discussed.

  1. ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study

    NASA Technical Reports Server (NTRS)

    Fridlind, Ann; Ackerman, Andrew; Petch, Jon; Field, Paul; Hill, Adrian; McFarquhar, Greg; Xie, Shaocheng; Zhang, Minghua

    2010-01-01

    Specifications are provided for running a cloud-resolving model (CRM) and submitting results in a standardized format for inclusion in a n intercomparison study and archiving for public access. The simulated case study is based on measurements obtained during the 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) led by the U. S. department of Energy Atmospheric Radiation Measurement (ARM) program. The modeling intercomparison study is based on objectives developed in concert with the Stratospheric Processes And their Role in Climate (SPARC) program and the GEWEX cloud system study (GCSS) program. The Global Energy and Water Cycle Experiment (GEWEX) is a core project of the World Climate Research PRogramme (WCRP).

  2. Latin American and Caribbean intercomparison of surface contamination monitoring equipment.

    PubMed

    Cabral, T S; Ramos, M M O; Laranjeira, A S; Santos, D S; Suarez, R C

    2011-03-01

    In October 2009, the International Atomic Energy Agency (IAEA) sponsored an intercomparison exercise of surface contamination monitoring equipment, which was held at the Laboratório Nacional de Metrologia das Radiações Ionizantes, from the Instituto de Radioproteção e Dosimetria, IRD/CNEN, Rio de Janeiro. This intercomparison was performed to evaluate the calibration accessibility in Latin America and the Caribbean. Thirteen countries within the region and IAEA have sent instruments to be compared, but only five countries and IAEA were considered apt to participate. Analysis of instruments, results and discussions are presented and recommendations are drawn. PMID:21051429

  3. Intercomparison of Global Precipitation Products: The Third Precipitation Intercomparison Project (PIP-3)

    NASA Technical Reports Server (NTRS)

    Adler, Robert F.; Kidd, Christopher; Petty, Grant; Morrissey, Mark; Goodman, H. Michael; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A set of global, monthly rainfall products has been intercompared to understand the quality and utility of the estimates. The products include 25 observational (satellite-based), four model and two climatological products. The results of the intercomparison indicate a very large range (factor of two or three) of values when all products are considered. The range of values is reduced considerably when the set of observational products is limited to those considered quasi-standard. The model products do significantly poorer in the tropics, but are competitive with satellite-based fields in mid-latitudes over land. Over ocean, products are compared to frequency of precipitation from ship observations. The evaluation of the observational products point to merged data products (including rain gauge information) as providing the overall best results.

  4. Water equivalence of NIPAM based polymer gel dosimeters with enhanced sensitivity for x-ray CT

    NASA Astrophysics Data System (ADS)

    Gorjiara, Tina; Hill, Robin; Bosi, Stephen; Kuncic, Zdenka; Baldock, Clive

    2013-10-01

    Two new formulations of N-isopropylacrylamide (NIPAM) based three dimensional (3D) gel dosimeters have recently been developed with improved sensitivity to x-ray CT readout, one without any co-solvent and the other one with isopropanol co-solvent. The water equivalence of the NIPAM gel dosimeters was investigated using different methods to calculate their radiological properties including: density, electron density, number of electrons per grams, effective atomic number, photon interaction probabilities, mass attenuation and energy absorption coefficients, electron collisional, radiative and total mass stopping powers and electron mass scattering power. Monte Carlo modelling was also used to compare the dose response of these gel dosimeters with water for kilovoltage and megavoltage x-ray beams and for megavoltage electron beams. We found that the density and electron density of the co-solvent free gel dosimeter are more water equivalent with less than a 2.6% difference compared to a 5.7% difference for the isopropanol gel dosimeter. Both the co-solvent free and isopropanol solvent gel dosimeters have lower effective atomic numbers than water, differing by 2.2% and 6.5%, respectively. As a result, their photoelectric absorption interaction probabilities are up to 6% and 19% different from water, respectively. Compton scattering and pair production interaction probabilities of NIPAM gel with isopropanol differ by up to 10% from water while for the co-solvent free gel, the differences are 3%. Mass attenuation and energy absorption coefficients of the co-solvent free gel dosimeter and the isopropanol gel dosimeter are up to 7% and 19% lower than water, respectively. Collisional and total mass stopping powers of both gel dosimeters differ by less than 2% from those of water. The dose response of the co-solvent free gel dosimeter is water equivalent (with <1% discrepancy) for dosimetry of x-rays with energies <100 keV while the discrepancy increases (up to 5%) for the

  5. Intercomparison of mid latitude storm diagnostics (IMILAST)

    NASA Astrophysics Data System (ADS)

    Neu, U.

    2009-04-01

    systematic intercomparison of different methodologies and a comprehensive assessment of all types of uncertainties inherent in the mid-latitudinal storm tracking by comparing different methodologies with respect to data of different resolution (time and space) and limited areas, for both cyclone identification and cyclone tracking respectively.

  6. TL detectors for gamma ray dose measurements in criticality accidents.

    PubMed

    Miljanić, Saveta; Zorko, Benjamin; Gregori, Beatriz; Knezević, Zeljka

    2007-01-01

    Determination of gamma ray dose in mixed neutron+gamma ray fields is still a demanding task. Dosemeters used for gamma ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e., on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosemeter responses to gamma rays. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma ray dose determination in the mixed fields were examined. Dosemeters were from three different institutions: Ruder Bosković Institute (RBI), Croatia, JoZef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. Three accidental scenarios were reproduced and in each irradiation the dosemeters were exposed placed on the front of phantom and 'free in air'. Following types of TLDs were used: 7LiF (TLD-700), CaF2:Mn and Al2O3:Mg,Y-all from RBI; CaF2:Mn from JSI and 7LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the values obtained from the results of all participants. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed. PMID:17369267

  7. An RF dosimeter for independent SAR measurement in MRI scanners

    SciTech Connect

    Qian, Di; Bottomley, Paul A.; El-Sharkawy, AbdEl-Monem M.; Edelstein, William A.

    2013-12-15

    Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on

  8. Lower limits of detection for thermal luminescent dosimeters

    SciTech Connect

    Spacher, P.J. ); Mis, F.J.; Klueber, M.R. )

    1990-08-01

    This paper reports that Groups of Panasonic UD-802 thermoluminescent dosimeters (TLDs) were irradiated to successively increasing doses of Cesium-137 gamma radiation (0.662 MeV gamma rays) and then processed using a Panasonic UD-710 automatic TLD reader. The results were subjected to statistical tests to determine the critical level, the level of detection, and the less-than level. The critical level is equivalent to 1.7 mrad, the lower limit of detection is equivalent to 5 mrad and the less-than level has a high range value of 7.5 mrad.

  9. PM 2.5 ORGANIC SPECIATION INTERCOMPARISON RESULTS

    EPA Science Inventory

    This abstract describes a poster on results to a laboratory intercomparison of organic aerosol speciation analysis to be presented at the 2006 International Aerosol Conference sponsored by the American Association for Aerosol Research in St. Paul, Minnesota on September 10-15. T...

  10. Terrestrial ultraviolet monitoring spectroradiometer intercomparisons: results and field standard development

    NASA Astrophysics Data System (ADS)

    Early, Edward A.; Thompson, Ambler E.

    1996-11-01

    Two interagency solar ultraviolet spectroradiometer intercomparisons (September 1994 and June 1995) have been conducted at Table Mountain outside Boulder, Colorado. A third intercomparison is planned for June 1996 at the same location. The intercomparisons were organized by the National Institute of Standards and Technology (NIST) at a field site supported by the National Oceanic and Atmospheric Administration and included participants representing North American agencies currently monitoring solar ultraviolet irradiance. Instruments were characterized at the intercomparisons for wavelength error, bandwidth, and stray- light rejection. All instruments were calibrated for spectral irradiance responsivity by NIST personnel with specially developed quartz-halogen field irradiance standards. Thus, comparisons of synchronized solar irradiance measurements allowed true comparisons between instruments, without the added complication of differences in irradiance scales of the participants. Estimates of differences in individual network propagation of irradiance scales were made separately. In addition, there were extensive concurrent ancillary measurements in an effort to compile a standard data set. We will discuss the results of these experiments and the overall agreement between the participants.

  11. Analytical Quality Control - Quality Assurance Iaea-Ilmr Intercomparison Programmes

    NASA Astrophysics Data System (ADS)

    Ballestra, S.; Vas, D.

    The importance of analytical quality control, especially for radionuclide measurements, was recognized at the International Atomic Energy Agency (IAEA) since it began operations in 1957. Activities at the International Laboratory of Marine Radioactivity (ILMR) in Monaco focused on radioisotope calibration to resolve measurement differences among laboratories all over the world. To-date, standardization and intercalibration remain key services of the ILMR at Monaco. Quality Assurance (QA) as well as Good Laboratory Practices (GLP) are manifestations of the increased attention being given to quality control. The programme, known as Analical Quality Control Services (AQCS), provides intercomparison studies and reference materials for natural and artificial radionuclides. Since the early 1970's, the ILMR has provided about 30 intercomparison samples and reference materials to laboratories all over the world to enable them to assess and control the quality of their work. Intercomparison and reference samples from the ILMR cover a wide range of materials and analytes in different concentration ranges. Natural matrix standards for radioactivity measurements for marine sediments, algae, and biota are available. The reference Samples produced through the resent intercomparison programmes are believe to play an important role in improving quality control in laboratories engaged in environmental radioactivity measurements.

  12. Evaluation of the annual Canadian biodosimetry network intercomparisons

    PubMed Central

    Wilkins, Ruth C.; Beaton-Green, Lindsay A.; Lachapelle, Sylvie; Kutzner, Barbara C.; Ferrarotto, Catherine; Chauhan, Vinita; Marro, Leonora; Livingston, Gordon K.; Boulay Greene, Hillary; Flegal, Farrah N.

    2015-01-01

    Abstract Purpose: To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response. Materials and methods: Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Intercomparisons were performed over a six-year period and comprised of the shipment of 10–12 irradiated, blinded blood samples for analysis by each of the participating laboratories. Dose estimates were determined by each laboratory using the dicentric chromosome assay (conventional and QuickScan scoring) and where possible the cytokinesis block micronucleus (CBMN) assay. Dose estimates were returned to the lead laboratory for evaluation and comparison. Results: Individual laboratories performed comparably from year to year with only slight fluctuations in performance. Dose estimates using the dicentric chromosome assay were accurate about 80% of the time and the QuickScan method for scoring the dicentric chromosome assay was proven to reduce the time of analysis without having a significant effect on the dose estimates. Although analysis with the CBMN assay was comparable to QuickScan scoring with respect to speed, the accuracy of the dose estimates was greatly reduced. Conclusions: Annual intercomparisons are necessary to maintain a network of laboratories for emergency response biodosimetry as they evoke confidence in their capabilities. PMID:25670072

  13. Analysis of anomalous data produced by Harshaw Model 8801 thermoluminescent dosimeter cards

    SciTech Connect

    Sonder, E.; Ahmed, A.B.

    1993-05-01

    A large number of dosimeters that have produced abnormal data during field assignment have been stored, reirradiated, and studied. Results are summarized and comparisons are made with normal dosimeters. Summarized here are anomalous glow curve shapes, distributions of anomalies in the residual luminescent responses, and historical and repeat-irradiation behavior of abnormal dosimeters. The results indicate that by far the most frequent abnormal data involve elevated readings from Chip 3, accompanied by excess luminescence at temperatures higher than that of the normal radiation produced band. There is no sharp division between normal and abnormal dosimeters (dosimeters yielding excess luminescence at high temperature). Rather, dosimeters exhibit a continuum of behavior from very good (little high temperature luminescence) to clearly abnormal behavior. The excess luminescence emitted at high temperature in abnormal dosimeters is not proportional to absorbed dose; it has a radiation-independent average value that depends on the dosimeter but varies erratically above and below that average for consecutive anneals. At relatively high radiation exposures (>100 mR), the amount of excess high temperature luminescence becomes unimportant and abnormal data are rare.

  14. Comparative study of three types of civil defense high-range pocket dosimeters

    SciTech Connect

    Siskel, R.L.; Sims, C.S.; Swaja, R.

    1987-01-01

    Civil defense shelters are stocked with high-range (0- to 200-R) CDV-742 pocket dosimeters. These dosimeters are intended for use by people that must leave the shelter when the environmental radiation level is either high or unknown. A total of 67 CDV-742 dosimeters were obtained and studied during the summer of 1986 at Oak Ridge National Lab. Health Physics Research Reactor (HPRR). Three different types of dosimeters (27 Bendix, 20 Landsverk-Gold, and 20 Landsverk-Yellow) in various combinations were exposed to 14 separate pulse operations of the HPRR. It can be concluded that the CDV-742 type dosimeters were not suitable for use in a neutron or mixed radiation field unless the spectra is known and correction factors determined in this study are properly applied. Further study is needed to determine the accuracy of these dosimeters in a pure gamma field and to determine their precision at the extreme ends of the dosimeter range. Furthermore, because of their failure rates, shelter occupants should consider exposure data from the Bendix and Landsverk-Yellow dosimeters to be highly unreliable unless sufficient evidence exists to support the exposure readings.

  15. Longevity Tests of High-Sensitivity BD-PND Bubble Dosimeters

    SciTech Connect

    Radev, R; Carlberg, E

    2002-07-09

    Medium- and very-high-sensitivity neutron bubble dosimeters (BD-PNDs) made by Bubble Technology Industries (BTI) were used to study the life span of such dosimeters in a standard setup with a {sup 252}Cf source. Although data on the longevity of bubble dosimeters with low and medium sensitivity exist, such data for dosimeters with high and very high sensitivity are not readily available. The manufacturer guarantees optimum dosimeter performance for 3 months after receipt. However, it is important to know the change in the dosimeters' characteristics with time, especially after the first 3 months. The long-term performance of four sets of very high sensitivity and one set of medium-sensitivity bubble dosimeters was examined for periods of up to 13 months. During that time, the detectors were exposed and reset more than 20 times. Although departures from initial detection sensitivity were observed in several cases, the detectors indicated a significantly longer life span than stated in the manufacturer's warranty. In addition, the change in the number of bubbles and in evaluated neutron dose as a function of the time from the end of exposure until the dosimeters were read was investigated.

  16. Adaptation of a Pocket PC for Use as a Wearable Voice Dosimeter

    ERIC Educational Resources Information Center

    Popolo, Peter S.; Svec, Jan G.; Titze, Ingo R.

    2005-01-01

    This article deals with the adaptation of a commercially available Pocket PC for use as a voice dosimeter, a wearable device that measures the vocal dose of teachers or other individuals on the job, at home, and elsewhere during the course of an entire day. An engineering approach for designing a voice dosimeter is described, and design data are…

  17. Injuries are not accidents

    PubMed Central

    Gutiérrez, María Isabel

    2014-01-01

    Injuries are the result of an acute exposure to exhort of energy or a consequence of a deficiency in a vital element that exceeds physiological thresholds resulting threatens life. They are classified as intentional or unintentional. Injuries are considered a global health issue because they cause more than 5 million deaths per year worldwide and they are an important contributor to the burden of disease, especially affecting people of low socioeconomic status in low- and middle-income countries. A common misconception exists where injuries are thought to be the same as accidents; however, accidents are largely used as chance events, without taken in consideration that all these are preventable. This review discusses injuries and accidents in the context of road traffic and emphasizes injuries as preventable events. An understanding of the essence of injuries enables the standardization of terminology in public use and facilitates the development of a culture of prevention among all of us. PMID:25386040

  18. Accident prevention manual

    SciTech Connect

    Not Available

    1998-05-01

    Among the many common needs and goals are the safety and well-being of families, ourselves, fellow employees, and the continuing success of this organization. To these ends--minimizing human suffering and economic waste--the Bonneville Power Administration (BPA) Accident Prevention Program and this Accident Prevention Manual (APM) are dedicated. The BPA Accident Prevention Program is revised as necessary to ensure compliance with relevant Federal safety and health standards. The mandatory rules herein express minimum requirements for dealing with the principal hazards inherent in daily work activities. These and other written requirements, which neither can nor should provide complete coverage of all work situations, must be continually reinforced through the sound and mature safety judgments of all workers on each assigned task. In the event of conflicting judgments, the more conservative interpretation shall prevail pending review and resolution by management.

  19. Low-cost solar array project: Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: Radiometer standards

    NASA Technical Reports Server (NTRS)

    Estey, R. S.; Seaman, C. H.

    1981-01-01

    Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

  20. Results of the NY-Alesund ozone measurements intercomparison NAOMI

    NASA Technical Reports Server (NTRS)

    Steinbrecht, W.; Gross, M.; McGee, T.; Neuber, R.; Gathen, P. V. D.; Wahl, P.; Klein, U.; Langer, J.

    1998-01-01

    Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

  1. The Fukushima radiation accident: consequences for radiation accident medical management.

    PubMed

    Meineke, Viktor; Dörr, Harald

    2012-08-01

    The March 2011 radiation accident in Fukushima, Japan, is a textbook example of a radiation accident of global significance. In view of the global dimensions of the accident, it is important to consider the lessons learned. In this context, emphasis must be placed on consequences for planning appropriate medical management for radiation accidents including, for example, estimates of necessary human and material resources. The specific characteristics of the radiation accident in Fukushima are thematically divided into five groups: the exceptional environmental influences on the Fukushima radiation accident, particular circumstances of the accident, differences in risk perception, changed psychosocial factors in the age of the Internet and globalization, and the ignorance of the effects of ionizing radiation both among the general public and health care professionals. Conclusions like the need for reviewing international communication, interfacing, and interface definitions will be drawn from the Fukushima radiation accident. PMID:22951483

  2. The Fukushima radiation accident: consequences for radiation accident medical management.

    PubMed

    Meineke, Viktor; Dörr, Harald

    2012-08-01

    The March 2011 radiation accident in Fukushima, Japan, is a textbook example of a radiation accident of global significance. In view of the global dimensions of the accident, it is important to consider the lessons learned. In this context, emphasis must be placed on consequences for planning appropriate medical management for radiation accidents including, for example, estimates of necessary human and material resources. The specific characteristics of the radiation accident in Fukushima are thematically divided into five groups: the exceptional environmental influences on the Fukushima radiation accident, particular circumstances of the accident, differences in risk perception, changed psychosocial factors in the age of the Internet and globalization, and the ignorance of the effects of ionizing radiation both among the general public and health care professionals. Conclusions like the need for reviewing international communication, interfacing, and interface definitions will be drawn from the Fukushima radiation accident.

  3. Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry.

    PubMed

    Lee, Bongsoo; Kwon, Guwon; Shin, Sang Hun; Kim, Jaeseok; Yoo, Wook Jae; Ji, Young Hoon; Jang, Kyoung Won

    2015-11-17

    In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter.

  4. Dosimeter for the measurement of UV exposures related to melanoma induction.

    PubMed

    Turnbull, David J; Parisi, Alfio V

    2010-07-01

    This paper reports on the development of a dosimeter for the measurement of biologically effective UV exposures related to melanoma induction. The melanoma (UVMel) dosimeter is based on the combination of polysulfone and nalidixic acid. This research found that the combination of these photosensitive chromophores reacts to UV wavelengths from 290 to 390 nm. It was found that a large change in optical absorbance occurred at 345 nm when the dosimeter was employed to quantify the solar UV waveband. Preliminary results indicate that this UVMel dosimeter can measure exposures of more than 189 kJ m(-2) of biologically effective weighted solar UV radiation with an inter-dosimeter variability of no more than +/-5%. PMID:20551501

  5. An analysis of an implantable dosimeter system for external beam therapy

    PubMed Central

    Black, Robert D.; Scarantino, Charles W.; Mann, Gregory G.; Anscher, Mitchell S.; Ornitz, Robert D.; Nelms, Benjamin E.

    2006-01-01

    Background and purpose To review the data from an implantable radiation dosimetry system used in a clinical setting and examine correlations between dosimeter readings and potential causative error sources. Material and methods MOSFET-based, encapsulated dosimeters were evaluated in a phantom (in vitro) and in a study with 18 patients. The dosimeters were placed in the gross tumor volume or in collateral normal tissue. Predicted dose values were established by imaging the dosimeters in the planning CT’s. Results The in vitro study confirmed that bounding cumulative errors due to setup, planning, and machine output within a +/−5% level is achievable. In patients, it was found that deviations from the targeted dose often exceeded the 5% level. Conclusions The use of an implantable dosimeter system could provide an effective empirical check on the dose delivered at depth. Such a tool may have value for institutional QA as well as for therapy delivered to individual patients. PMID:16111599

  6. Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry

    PubMed Central

    Lee, Bongsoo; Kwon, Guwon; Shin, Sang Hun; Kim, Jaeseok; Yoo, Wook Jae; Ji, Young Hoon; Jang, Kyoung Won

    2015-01-01

    In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter. PMID:26593917

  7. A modified Fricke gel dosimeter for fast electron blood dosimetry

    NASA Astrophysics Data System (ADS)

    Del Lama, L. S.; de Góes, E. G.; Sampaio, F. G. A.; Petchevist, P. C. D.; de Almeida, A.

    2014-12-01

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXGp) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXGp dosimeter were also able to provide isodose curves and field profiles for the irradiated samples.

  8. Occupational accidents aboard merchant ships

    PubMed Central

    Hansen, H; Nielsen, D; Frydenberg, M

    2002-01-01

    Objectives: To investigate the frequency, circumstances, and causes of occupational accidents aboard merchant ships in international trade, and to identify risk factors for the occurrence of occupational accidents as well as dangerous working situations where possible preventive measures may be initiated. Methods: The study is a historical follow up on occupational accidents among crew aboard Danish merchant ships in the period 1993–7. Data were extracted from the Danish Maritime Authority and insurance data. Exact data on time at risk were available. Results: A total of 1993 accidents were identified during a total of 31 140 years at sea. Among these, 209 accidents resulted in permanent disability of 5% or more, and 27 were fatal. The mean risk of having an occupational accident was 6.4/100 years at sea and the risk of an accident causing a permanent disability of 5% or more was 0.67/100 years aboard. Relative risks for notified accidents and accidents causing permanent disability of 5% or more were calculated in a multivariate analysis including ship type, occupation, age, time on board, change of ship since last employment period, and nationality. Foreigners had a considerably lower recorded rate of accidents than Danish citizens. Age was a major risk factor for accidents causing permanent disability. Change of ship and the first period aboard a particular ship were identified as risk factors. Walking from one place to another aboard the ship caused serious accidents. The most serious accidents happened on deck. Conclusions: It was possible to clearly identify work situations and specific risk factors for accidents aboard merchant ships. Most accidents happened while performing daily routine duties. Preventive measures should focus on workplace instructions for all important functions aboard and also on the prevention of accidents caused by walking around aboard the ship. PMID:11850550

  9. Characterization and intercomparison of aerosol absorption photometers: result of two intercomparison workshops

    NASA Astrophysics Data System (ADS)

    Müller, T.; Henzing, J. S.; de Leeuw, G.; Wiedensohler, A.; Alastuey, A.; Angelov, H.; Bizjak, M.; Collaud Coen, M.; Engström, J. E.; Gruening, C.; Hillamo, R.; Hoffer, A.; Imre, K.; Ivanow, P.; Jennings, G.; Sun, J. Y.; Kalivitis, N.; Karlsson, H.; Komppula, M.; Laj, P.; Li, S.-M.; Lunder, C.; Marinoni, A.; Martins Dos Santos, S.; Moerman, M.; Nowak, A.; Ogren, J. A.; Petzold, A.; Pichon, J. M.; Rodriquez, S.; Sharma, S.; Sheridan, P. J.; Teinilä, K.; Tuch, T.; Viana, M.; Virkkula, A.; Weingartner, E.; Wilhelm, R.; Wang, Y. Q.

    2010-04-01

    Absorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.

  10. Characterization and intercomparison of aerosol absorption photometers: result of two intercomparison workshops

    NASA Astrophysics Data System (ADS)

    Müller, T.; Henzing, J. S.; de Leeuw, G.; Wiedensohler, A.; Alastuey, A.; Angelov, H.; Bizjak, M.; Collaud Coen, M.; Engström, J. E.; Gruening, C.; Hillamo, R.; Hoffer, A.; Imre, K.; Ivanow, P.; Jennings, G.; Sun, J. Y.; Kalivitis, N.; Karlsson, H.; Komppula, M.; Laj, P.; Li, S.-M.; Lunder, C.; Marinoni, A.; Martins Dos Santos, S.; Moerman, M.; Nowak, A.; Ogren, J. A.; Petzold, A.; Pichon, J. M.; Rodriquez, S.; Sharma, S.; Sheridan, P. J.; Teinilä, K.; Tuch, T.; Viana, M.; Virkkula, A.; Weingartner, E.; Wilhelm, R.; Wang, Y. Q.

    2011-02-01

    Absorption photometers for real time application have been available since the 1980s, but the use of filter-based instruments to derive information on aerosol properties (absorption coefficient and black carbon, BC) is still a matter of debate. Several workshops have been conducted to investigate the performance of individual instruments over the intervening years. Two workshops with large sets of aerosol absorption photometers were conducted in 2005 and 2007. The data from these instruments were corrected using existing methods before further analysis. The inter-comparison shows a large variation between the responses to absorbing aerosol particles for different types of instruments. The unit to unit variability between instruments can be up to 30% for Particle Soot Absorption Photometers (PSAPs) and Aethalometers. Multi Angle Absorption Photometers (MAAPs) showed a variability of less than 5%. Reasons for the high variability were identified to be variations in sample flow and spot size. It was observed that different flow rates influence system performance with respect to response to absorption and instrumental noise. Measurements with non absorbing particles showed that the current corrections of a cross sensitivity to particle scattering are not sufficient. Remaining cross sensitivities were found to be a function of the total particle load on the filter. The large variation between the response to absorbing aerosol particles for different types of instruments indicates that current correction functions for absorption photometers are not adequate.

  11. Is a quasi-3D dosimeter better than a 2D dosimeter for Tomotherapy delivery quality assurance?

    NASA Astrophysics Data System (ADS)

    Xing, Aitang; Deshpande, Shrikant; Arumugam, Sankar; George, Armia; Holloway, Lois; Vial, Philip; Goozee, Gary

    2015-01-01

    Delivery quality assurance (DQA) has been performed for each Tomotherapy patient either using ArcCHECK or MatriXX Evolution in our clinic since 2012. ArcCHECK is a quasi-3D dosimeter whereas MatriXX is a 2D detector. A review of DQA results was performed for all patients in the last three years, a total of 221 DQA plans. These DQA plans came from 215 patients with a variety of treatment sites including head-neck, pelvis, and chest wall. The acceptable Gamma pass rate in our clinic is over 95% using 3mm and 3% of maximum planned dose with 10% dose threshold. The mean value and standard deviation of Gamma pass rates were 98.2% ± 1.98(1SD) for MatriXX and 98.5%±1.88 (1SD) for ArcCHECK. A paired t-test was also performed for the groups of patients whose DQA was performed with both the ArcCHECK and MatriXX. No statistical dependence was found in terms of the Gamma pass rate for ArcCHECK and MatriXX. The considered 3D and 2D dosimeters have achieved similar results in performing routine patient-specific DQA for patients treated on a TomoTherapy unit.

  12. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

    SciTech Connect

    McCaw, Travis J. Micka, John A.; DeWerd, Larry A.

    2014-05-15

    Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the

  13. Characterization of the nanoDot OSLD dosimeter in CT

    SciTech Connect

    Scarboro, Sarah B.; Cody, Dianna; Followill, David; Court, Laurence; Stingo, Francesco C.; Kry, Stephen F.; Alvarez, Paola; Zhang, Di; McNitt-Gray, Michael

    2015-04-15

    Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due

  14. Characterization of the nanoDot OSLD dosimeter in CT

    PubMed Central

    Scarboro, Sarah B.; Cody, Dianna; Alvarez, Paola; Followill, David; Court, Laurence; Stingo, Francesco C.; Zhang, Di; Kry, Stephen F.

    2015-01-01

    Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due

  15. Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams.

    PubMed

    Arun, C; Palani Selvam, T; Dinkar, Verma; Munshi, Prabhat; Kalra, Manjit Singh

    2013-01-01

    This study presents Monte Carlo-calculated absolute and normalized (relative to a (60)Co beam) sensitivity values of silicon diode dosimeters for a variety of commercially available silicon diode dosimeters for radiotherapy photon beams in the energy range of (60)Co-24 MV. These values were obtained at 5 cm depth along the central axis of a water-equivalent phantom of 10 cm × 10 cm field size. The Monte Carlo calculations were based on the EGSnrc code system. The diode dosimeters considered in the calculations have different buildup materials such as aluminum, brass, copper, and stainless steel + epoxy. The calculated normalized sensitivity values of the diode dosimeters were then compared to previously published measured values for photon beams at (60)Co-20 MV. The comparison showed reasonable agreement for some diode dosimeters and deviations of 5-17 % (17 % for the 3.4 mm brass buildup case for a 10 MV beam) for some diode dosimeters. Larger deviations of the measurements reflect that these models of the diode dosimeter were too simple. The effect of wall materials on the absorbed dose to the diode was studied and the results are presented. Spencer-Attix and Bragg-Gray stopping power ratios (SPRs) of water-to-diode were calculated at 5 cm depth in water. The Bragg-Gray SPRs of water-to-diode compare well with Spencer-Attix SPRs for ∆ = 100 keV and above at all beam qualities.

  16. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere

    SciTech Connect

    Yang, Zhen; Chen, Bo Zhuo, Weihai; Fan, Dunhuang; Zhang, Yu; Zhao, Chao

    2015-12-15

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of {sup 137}Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  17. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere.

    PubMed

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of (137)Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  18. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere.

    PubMed

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of (137)Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account. PMID:26724019

  19. Evaluation of a high exposure solar UV dosimeter for underwater use.

    PubMed

    Schouten, Peter W; Parisi, Alfio V; Turnbull, David J

    2007-01-01

    Solar ultraviolet radiation (UV) is known to have a significant effect upon the marine ecosystem. This has been documented by many previous studies using a variety of measurement methods in aquatic environments such as oceans, streams and lakes. Evidence gathered from these investigations has shown that UVB radiation (280-320 nm) can negatively affect numerous aquatic life forms, while UVA radiation (320-400 nm) can both damage and possibly even repair certain types of underwater life. Chemical dosimeters such as polysulphone have been tested to record underwater UV exposures and in turn quantify the relationship between water column depth and dissolved organic carbon levels to the distribution of biologically damaging UV underwater. However, these studies have only been able to intercept UV exposures over relatively short time intervals. This paper reports on the evaluation of a high exposure UV dosimeter for underwater use. The UV dosimeter was fabricated from poly 2,6-dimethyl-1,4-phenylene oxide (PPO) film. This paper presents the dose response, cosine response, exposure additivity and watermarking effect relating to the PPO dosimeter as measured in a controlled underwater environment and will also detail the overnight dark reaction and UVA and visible radiation response of the PPO dosimeter, which can be used for error correction to improve the reliability of the UV data measured by the PPO dosimeters. These results show that this dosimeter has the potential for long-term underwater UV exposure measurements. PMID:17645666

  20. Monte Carlo simulation of single and two-dosimeter approaches in a steam generator channel head.

    PubMed

    Kim, C H; Reece, W D

    2002-08-01

    In a steam generator channel head, it was not unusual to see radiation workers wearing as many as twelve dosimeters over the surface of the body to avoid a possible underestimation of effective dose equivalent (H(E)) or effective dose (E). This study shows that only one or two dosimeters can be used to estimate H(E) and E without a significant underestimation. MCNP and a point-kernel approach were used to model various exposure situations in a steam generator channel head. The single-dosimeter approach (on the chest) was found to underestimate H(E) and E significantly for a few exposure situations, i.e., when the major portion of radiation source is located in the backside of a radiation worker. In this case, the photons from the source pass through the body and are attenuated before reaching the dosimeter on the chest. To assure that a single dosimeter provides a good estimate of worker dose, these few exposure situations cannot dominate a worker's exposure. On the other hand, the two-dosimeter approach (on the chest and back) predicts H(E) and E very well, hardly ever underestimating these quantities by more than 4% considering all worker positions and contamination situations in a steam generator channel head. This study shows that two dosimeters are adequate for an accurate estimation of H(E) and E in a steam generator channel head. PMID:12132712

  1. Applying STAMP in Accident Analysis

    NASA Technical Reports Server (NTRS)

    Leveson, Nancy; Daouk, Mirna; Dulac, Nicolas; Marais, Karen

    2003-01-01

    Accident models play a critical role in accident investigation and analysis. Most traditional models are based on an underlying chain of events. These models, however, have serious limitations when used for complex, socio-technical systems. Previously, Leveson proposed a new accident model (STAMP) based on system theory. In STAMP, the basic concept is not an event but a constraint. This paper shows how STAMP can be applied to accident analysis using three different views or models of the accident process and proposes a notation for describing this process.

  2. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    SciTech Connect

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford's mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  3. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    SciTech Connect

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford`s mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  4. An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimeters

    NASA Astrophysics Data System (ADS)

    Babic, Steven; Schreiner, L. John

    2006-09-01

    In conformal radiation therapy, a high dose of radiation is given to a target volume to increase the probability of cure, and care is taken to minimize the dose to surrounding healthy tissue. The techniques used to achieve this are very complicated and the precise verification of the resulting three-dimensional (3D) dose distribution is required. Polyacrylamide gelatin (PAG) dosimeters with magnetic resonance imaging and optical computed tomography scanning provide the required 3D dosimetry with high spatial resolution. Many basic studies have characterized these chemical dosimeters that polymerize under irradiation. However, the investigation of the fundamental properties of the radiation-induced polymerization in PAG dosimeters is complicated by the presence of the background gelatin matrix. In this work, a gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters has been developed. Experiments were performed on gelatin-free dosimeters, named aqueous polyacrylamide (APA) dosimeters, containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide. The APA dosimeters were prepared with four different total monomer concentrations (2, 4, 6 and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all four dosimeters, show a continuous degree of polymerization over the dose range of 0-25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of crosslinked polymer formed at each dose. This model can be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.

  5. An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimeters.

    PubMed

    Babic, Steven; Schreiner, L John

    2006-09-01

    In conformal radiation therapy, a high dose of radiation is given to a target volume to increase the probability of cure, and care is taken to minimize the dose to surrounding healthy tissue. The techniques used to achieve this are very complicated and the precise verification of the resulting three-dimensional (3D) dose distribution is required. Polyacrylamide gelatin (PAG) dosimeters with magnetic resonance imaging and optical computed tomography scanning provide the required 3D dosimetry with high spatial resolution. Many basic studies have characterized these chemical dosimeters that polymerize under irradiation. However, the investigation of the fundamental properties of the radiation-induced polymerization in PAG dosimeters is complicated by the presence of the background gelatin matrix. In this work, a gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters has been developed. Experiments were performed on gelatin-free dosimeters, named aqueous polyacrylamide (APA) dosimeters, containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide. The APA dosimeters were prepared with four different total monomer concentrations (2, 4, 6 and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all four dosimeters, show a continuous degree of polymerization over the dose range of 0-25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of crosslinked polymer formed at each dose. This model can be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters. PMID:16912375

  6. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    SciTech Connect

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, E.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements of the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.

  7. Tractor accidents in Swedish traffic.

    PubMed

    Pinzke, Stefan; Nilsson, Kerstin; Lundqvist, Peter

    2012-01-01

    The objective of this study is to reach a better understanding of accidents on Swedish roads involving tractors and to suggest ways of preventing them. In an earlier study we analyzed police-reported fatal accidents and accidents that led to physical injuries from 1992 to 2005. During each year of this period, tractors were involved in 128 traffic accidents on average, an average of 7 people were killed, 44 sustained serious injuries, and 143 sustained slight injuries. The number of fatalities in these tractor accidents was about 1.3% of all deaths in traffic accidents in Sweden. Cars were most often involved in the tractor accidents (58%) and 15% were single vehicle accidents. The mean age of the tractor driver involved was 39.8 years and young drivers (15-24 years) were overrepresented (30%). We are now increasing the data collected with the years 2006-2010 in order to study the changes in the number of accidents. Special attention will be given to the younger drivers and to single vehicle accidents. Based on the results we aim to develop suggestions for reducing road accidents, e.g. including measures for making farm vehicles more visible and improvement of the training provided at driving schools. PMID:22317543

  8. Intercomparison of TCCON and MUSICA Water Vapour Products

    NASA Astrophysics Data System (ADS)

    Weaver, D.; Strong, K.; Deutscher, N. M.; Schneider, M.; Blumenstock, T.; Robinson, J.; Notholt, J.; Sherlock, V.; Griffith, D. W. T.; Barthlott, S.; García, O. E.; Smale, D.; Palm, M.; Jones, N. B.; Hase, F.; Kivi, R.; Ramos, Y. G.; Yoshimura, K.; Sepúlveda, E.; Gómez-Peláez, Á. J.; Gisi, M.; Kohlhepp, R.; Warneke, T.; Dohe, S.; Wiegele, A.; Christner, E.; Lejeune, B.; Demoulin, P.

    2014-12-01

    We present an intercomparison between the water vapour products from the Total Carbon Column Observing Network (TCCON) and the MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water (MUSICA), two datasets from ground-based Fourier Transform InfraRed (FTIR) spectrometers with good global representation. Where possible, comparisons to radiosondes are also included. The near-infrared TCCON measurements are optimized to provide precise monitoring of greenhouse gases for carbon cycle studies; however, TCCON's retrievals also produce water vapour products. The mid-infrared MUSICA products result from retrievals optimized to give precise and accurate information about H2O, HDO, and δD. The MUSICA water vapour products have been validated by extensive intercomparisons with H2O and δD in-situ measurements made from ground, radiosonde, and aircraft (Schneider et al. 2012, 2014), as well as by intercomparisons with satellite-based H2O and δD remote sensing measurements (Wiegele et al., 2014). This dataset provides a valuable reference point for other measurements of water vapour. This study is motivated by the limited intercomparisons performed for TCCON water vapour products and limited characterisation of their uncertainties. We compare MUSICA and TCCON products to assess the potential for TCCON measurements to contribute to studies of the water cycle, water vapour's role in climate and use as a tracer for atmospheric dynamics, and to evaluate the performance of climate models. The TCCON and MUSICA products result from measurements taken using the same FTIR instruments, enabling a comparison with constant instrumentation. The retrieval techniques differ, however, in their method and a priori information. We assess the impact of these differences and characterize the comparability of the TCCON and MUSICA datasets.

  9. Bootstrap-based intercomparison of regional flood estimation procedures

    SciTech Connect

    Ouarda, T.B.M.J.; Ashkar, F.

    1995-12-31

    The present paper describes a methodology, based on the regional bootstrap procedure, for the intercomparison of some of the most frequently used regional flood frequency estimation models. The results of the application of this methodology, with Canadian flood data, for comparing the different regional estimation models are also presented. A regional model C{sub ij} = [DRH]{sub i} x [MER]{sub j} (i=1,...,L ; j=1,...,M) is obtained by combining a methodology for the delineation of homogeneous regions [DRH]{sub i} and a regional estimation method [MER]{sub j}. These regional models are compared with respect to their ability to provide reliable estimates of certain flood quantiles (floods with return periods of 10 and 100 years). Two types of bootstrapping have been applied within the framework of this project: the classical scalar bootstrap used in at-site estimation, and the vector (or regional) bootstrap procedure applied in the intercomparison between the different regional models. This last technique is illustrated with an example, and all the details of the procedure are presented. The performance indices that were employed for the purpose of the intercomparison are also detailed. One important feature of regional bootstrapping is that it preserves the regional dependence structure between annual flood values at the different sites of an {open_quote}homogeneous{close_quote} region. Three versions of the regional bootstrap algorithm are presented and applied to the three cases of estimation-regional estimation for ungauged sites, regional estimation for gauged sites with a short record, and at-site estimation. It will be shown how at-site estimates can be used as basis for the intercomparison between the regional models. Results of the application of the bootstrap procedure, with flood data from the Provinces of Quebec and Ontario, are presented in the final section of the paper.

  10. An Intercomparison of Airborne VOC and PAN Measurements

    NASA Astrophysics Data System (ADS)

    Hansel, A.; Wisthaler, A.; Flocke, F.; Weinheimer, A.; Fall, R.; Goldan, P.; Hübler, G.; Fehsenfeld, F. C.

    2002-12-01

    As part of the Texas Air Quality Study (TexAQS 2000) an informal airborne intercomparison has been conducted to evaluate the state-of-the-art of fast-response, in-situ methods for analyzing Volatile Organic Compounds (VOCs) and peroxyacetyl nitrate (PAN). Instrumentation included a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS), the Tropospheric Airborne Chromatograph for Oxy-hydrocarbons and Hydrocarbons (TACOH) and a gas chromatograph for PAN detection using electron capture (GC/ECD). The measurements were made in the Greater Houston area and East Texas in August/September 2000 during 13 flights with the NSF/NCAR ELECTRA aircraft. The intercomparison was conducted mainly in the boundary layer but included some encounters with air masses from the free troposphere. Final results from the intercomparison show that measurements of acetaldehyde, isoprene, the sum\\textsuperscript{*} of acetone and propanal, the sum\\textsuperscript{*} methyl vinyl ketone and methacrolein (\\textsuperscript{*} PTR-MS does not distinguish between isobaric species) and toluene agree very well. Poor agreement was achieved in the case of methanol and the underlying sensitivity problem in the PTR-MS or TACOH system is under investigation. The results of the PAN intercomparison indicate that the PTR-MS technique suffered from an interference most likely associated with the presence of peracetic acid in photochemically aged air. If this interfering signal was traced by periodically inserting a selective PAN scrubber (thermal decomposition) into the sample air stream and subtracted from the original signal, the corrected PTR-MS PAN data are in very good agreement with the GC/ECD results.

  11. Dental enamel as an in vivo radiation dosimeter

    SciTech Connect

    Pass, B.; Aldrich, J.E.

    1985-05-01

    The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue which retains indefinitely its radiation history, and electron spin resonance measurements have shown that the radiation signal can be resolved down to about 10 cGy. Measurements on samples from the general population give radiation exposure estimates that are reasonable, and one measurement on a patient who had radiotherapy to the mouth area showed a good correlation with tumor dose.We believe that this is an important new indicator of radiation dose and taken together with exposure histories should provide important data for epidemiological studies as well as accidental exposures.

  12. [AOR characterization and zoning: a dosimeter for blue light].

    PubMed

    Dario, R; Uva, J; Di Lecce, V; Quarto, A

    2011-01-01

    The paper presents the results obtained thanks to an innovative experimental device for the assessment of artificial optical radiation (AOR) exposure in workplace. This . device was developed by 'Politecnico di Bari-DIASS'. The wearable personal dosimeter has three sensors: one is used for measuring head position/movement, therefore there is a color light sensor to determine the AOR and finally there is a video camera to localize sources. Our system is connected to a netbook via USB cable that allows one to obtain the real and extimated value of worker's exposure, also with "augmented reality". The aim of this paper is realizing work place safety zoning for the classifacation of not only specific dangerous areas through the analysis of overlapping information from the device. PMID:23393888

  13. Review of four novel dosimeters developed for use in radiotherapy

    NASA Astrophysics Data System (ADS)

    Metcalfe, P.; Quinn, A.; Loo, K.; Lerch, M.; Petasecca, M.; Wong, J.; Hardcastle, N.; Carolan, M.; McNamara, J.; Cutajar, D.; Fuduli, I.; Espinoza, A.; Porumb, C.; Rosenfeld, A.

    2013-06-01

    Centre for Medical Radiation Physics (CMRP) is a research strength at the University of Wollongong, the main research theme of this centre is to develop prototype novel radiation dosimeters. Multiple detector systems have been developed by Prof Rosenfelds' group for various radiation detector applications. This paper focuses on four current detector systems being developed and studied at CMRP. Two silicon array detectors include the magic plate and dose magnifying glass (DMG), the primary focus of these two detectors is high spatial and temporal resolution dosimetry in intensity modulated radiation therapy (IMRT) beams. The third detector discussed is the MOSkinTM which is a high spatial resolution detector based on MOSFET technology, its primary role is in vivo dosimetry. The fourth detector system discussed is BrachyView, this is a high resolution dose viewing system based on Medipix detector technology.

  14. [AOR characterization and zoning: a dosimeter for blue light].

    PubMed

    Dario, R; Uva, J; Di Lecce, V; Quarto, A

    2011-01-01

    The paper presents the results obtained thanks to an innovative experimental device for the assessment of artificial optical radiation (AOR) exposure in workplace. This . device was developed by 'Politecnico di Bari-DIASS'. The wearable personal dosimeter has three sensors: one is used for measuring head position/movement, therefore there is a color light sensor to determine the AOR and finally there is a video camera to localize sources. Our system is connected to a netbook via USB cable that allows one to obtain the real and extimated value of worker's exposure, also with "augmented reality". The aim of this paper is realizing work place safety zoning for the classifacation of not only specific dangerous areas through the analysis of overlapping information from the device.

  15. Applicability of the Sunna dosimeter for food irradiation control

    NASA Astrophysics Data System (ADS)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.; Miller, S.; Murphy, M.; McLaughlin, W. L.; Slezsák, I.; Kovács, A. I.

    2002-03-01

    The quick development concerning the commercial application of food irradiation in the USA recently resulted in growing marketing of irradiated red meat as well as irradiated fresh and dried fruits. These gamma and electron irradiation technologies require specific dosimetry systems for process control. The new version of the Sunna dosimeter has been characterized in gamma, electron and bremsstrahlung radiation fields by measuring the optically stimulated luminescence (osl) at 530 nm both below and above 1 kGy, i.e. for disinfestation and for meat irradiation purposes. No humidity and no significant dose rate effect on the green osl signal was observed. The temperature coefficient was determined from 0°C up to about 40°C and to stabilize the osl signal after irradiation a heat treatment method was introduced. Based on these investigations the Sunna 'gamma' film is a suitable candidate for dose control below and above 1 kGy for food irradiation technologies.

  16. Calibration results obtained with Liulin-4 type dosimeters.

    PubMed

    Dachev, Ts; Tomov, B; Matviichuk, Yu; Dimitrov, Pl; Lemaire, J; Gregoire, Gh; Cyamukungu, M; Schmitz, H; Fujitaka, K; Uchihori, Y; Kitamura, H; Reitz, G; Beaujean, R; Petrov, V; Shurshakov, V; Benghin, V; Spurny, F

    2002-01-01

    The Mobile Radiation Exposure Control System's (Liulin-4 type) main purpose is to monitor simultaneously the doses and fluxes at 4 independent places. It can also be used for personnel dosimetry. The system consists of 4 battery-operated 256-channel dosimeters-spectrometers. We describe results obtained during the calibrations of the spectrometers at the Cyclotron facilities of the University of Louvain, Belgium and of the National Institute of Radiological Sciences-STA, Chiba, Japan with protons of energies up to 70 MeV. The angular sensitivities of the devices are studied and compared with Monte-Carlo predictions. We also present the results obtained at the HIMAC accelerator with 500 MeV/u Fe ions and at the CERN high energy radiation reference fields. Records made during airplane flights are shown and compared with the predictions of the CARI-6 model.

  17. A Radiation Dosimeter Concept for the Lunar Surface Environment

    NASA Technical Reports Server (NTRS)

    Adams, James H.; Christl, Mark J.; Watts, John; Kuznetsov, Eugeny N.; Parnell, Thomas A.; Pendleton, Geoff N.

    2007-01-01

    A novel silicon detector configuration for radiation dose measurements in an environment where solar energetic particles are of most concern is described. The dosimeter would also measure the dose from galactic cosmic rays. In the lunar environment a large range in particle flux and ionization density must be measured and converted to dose equivalent. This could be accomplished with a thick (e.g. 2mm) silicon detector segmented into cubic volume elements "voxels" followed by a second, thin monolithic silicon detector. The electronics needed to implement this detector concept include analog signal processors (ASIC) and a field programmable gate array (FPGA) for data accumulation and conversion to linear energy transfer (LET) spectra and to dose-equivalent (Sievert). Currently available commercial ASIC's and FPGA's are suitable for implementing the analog and digital systems.

  18. Preliminary dosimetry investigation of Tc-99m diagnostic radionuclide by NIPAM gel dosimeter

    NASA Astrophysics Data System (ADS)

    Huang, You-Ruei; Chang, Yuan-Jen; Hsieh, Ling-Ling; Yu, Bi-Wei; Chu, Chien-Hau; Hsieh, Bor-Tsung

    2013-06-01

    The N-isopropylacrylamide (NIPAM) gel dosimeter was investigated as a suitable material for measuring absorbed doses from radionuclide sources. In this study, NIPAM gel dosimeter was used to evaluate the dose distributions of the Tc-99m radionuclide in NIPAM gel. The accumulated radioactivity range of the Tc-99m NIPAM gel is from approximately 0 MBq to 13.6 MBq (about 0.37 mCi). The NIPAM gel dosimeter with high stability and high-dose linear and non-energy dependent properties can provide various radiopharmaceutical activity intensities in the conduct of dose assessment in nuclear medicine, thereby producing the most promising dose verification tools.

  19. Laboratory facilities and recommendations for the characterization of biological ultraviolet dosimeters.

    PubMed

    Bolsée, D; Webb, A R; Gillotay, D; Dörschel, B; Knuschke, P; Krins, A; Terenetskaya, I

    2000-06-01

    A laboratory facility for characterizing biological dosimeters for the measurement of UV radiation has been built and tested. The facility is based on a solar simulator, stabilized by photofeedback, and monitored by a spectroradiometer, with a versatile filter arrangement. This enables the following characteristics of the dosimeters to be ascertained: spectral response, linearity, and reciprocity; angular acceptance and response; calibration in simulated sunlight. The system has been tested on a variety of dosimeters and has the potential to be used with other radiometers, subject currently to the size of their active surface. PMID:18345205

  20. Measurement of a 200 MeV proton beam using a polyurethane dosimeter

    NASA Astrophysics Data System (ADS)

    Heard, Malcolm; Adamovics, John; Ibbott, Geoffrey

    2006-12-01

    PRESAGETM (Heuris Pharma LLC, Skillman, NJ) is a three-dimensional polyurethane dosimeter containing a leuco dye that generates a color change when irradiated. The dosimeter is solid and does not require a container to maintain its shape. The dosimeter is transparent before irradiation and the maximum absorbance of the leuco dye occurs at 633 nm which is compatible with the OCT-OPUSTM laser CT scanner (MGS Research, Inc., Madison, CT). The purpose of this study was to investigate the response of PRESAGETM to proton beam radiotherapy.

  1. [Skateboard and rollerskate accidents].

    PubMed

    Lohmann, M; Petersen, A O; Pedersen, O D

    1990-05-28

    The increasing popularity of skateboards and rollerskates has resulted in an increased number of contacts with the casualty department in Denmark after accidents. As part of the Danish share in the EHLASS project (European Home and Leisure Surveillance System), 120,000 consecutive contacts with the casualty departments were reviewed. Out of these 516 were due to accidents with skateboards and rollerskates (181/335). A total of 194 of these injuries (38%) were fractures and 80% of these were in the upper limbs. Twenty fractures required reposition under general anaesthesia and two required osteosynthesis. Nine patients were admitted for observation for concussion. One patient had sustained rupture of the spleen and splenectomy was necessary. A total of 44 patients were admitted. None of the 516 patients had employed protective equipment on the injured region. Considerable reduction in the number of injuries could probably be produced by employment of suitable protective equipment.

  2. [Drowning accidents in childhood].

    PubMed

    Krandick, G; Mantel, K

    1990-09-30

    This is a report on five boys aged between 1 and 5 years who, after prolonged submersion in cold water, were treated at our department. On being taken out of the water, all the patients were clinically dead. After 1- to 3-hour successful cardiopulmonary resuscitation, with a rectal temperature of about 27 degrees C, they were rewarmed at a rate of 1 degree/hour. Two patients died within a few hours after the accident. One patient survived with an apallic syndrome, 2 children survived with no sequelae. In the event of a water-related accident associated with hypothermia, we consider suitable resuscitation to have preference over rewarming measures. The most important treatment guidelines and prognostic factors are discussed.

  3. Farm accidents in children.

    PubMed

    Cogbill, T H; Busch, H M; Stiers, G R

    1985-10-01

    During a 6 1/2 year period, 105 children were admitted to the hospital as the result of trauma that occurred on farms. The mechanism of injury was animal related in 42 (40%), tractor or wagon accident in 28 (26%), farm machinery in 21 (20%), fall from farm building in six (6%), and miscellaneous in eight (8%). Injury Severity Score was calculated for each patient. An Injury Severity Score of greater than or equal to 25 was determined for 11 children (11%). Life-threatening injuries, therefore, are frequently the result of childhood activities that take place in agricultural environments. The most common injuries were orthopedic, neurologic, thoracoabdominal, and maxillofacial. There was one death in the series, and only one survivor sustained major long-term disability. Such injuries are managed with optimal outcome in a regional trauma center. Educational programs with an emphasis on prevention and safety measures may reduce the incidence of farm accidents. PMID:4047799

  4. Intercomparison measurements with energy deposition spectrometer Liulin and TEPC Hawk at HIMAC, and related calculations with PHITS

    NASA Astrophysics Data System (ADS)

    Ploc, Ondrej; Uchihori, Yukio; Kitamura, H.; Kodaira, S.; Dachev, Tsvetan; Spurny, Frantisek; Jadrnickova, Iva; Mrazova, Zlata; Kubancak, Jan

    Liulin type detectors are recently used in a wide range of cosmic radiation measurements, e.g. at alpine observatories, onboard aircrafts and spacecrafts. They provide energy deposition spectra up to 21 MeV, higher energy deposition events are stored in the last (overflow) channel. Their main advantages are portability (about the same size as a pack of cigarettes) and ability to record spectra as a function of time, so they can be used as personal dosimeters. Their well-known limitations are: (i) the fact that they are not tissue equivalent, (ii) they can be used as LET spectrometer only under specific conditions (e.g. broad parallel beam), and (iii) that the energy deposition event from particles of LETH20¿35 keV/µm is stored in the overflow bin only so the spectral information is missing. Tissue equivalent proportional counter (TEPC) Hawk has no of these limitations but on the other hand, it cannot be used as personal dosimeter because of its big size (cylinder of 16 cm diameter and 34 cm long). An important fraction of dose equivalent onboard spacecrafts is caused by heavy ions. This contribution presents results from intercomparison measurements with Liulin and Hawk at Heavy Ion Medical Accelerator in Chiba (HIMAC) and cyclotron beams, and related calculations with PHITS (Particle and Heavy-ion Transport code System). Following particles/ions and energies were used: protons 70 MeV, He 150 MeV, Ne 400 MeV, C 135 MeV, C 290 MeV, and Fe 500 MeV. Calculations of LET spectra by PHITS were performed for both, Liulin and Hawk. In case of Liulin, the dose equivalent was calculated using simulations in which several tissue equivalent materials were used as active volume instead of the silicon diode. Dose equivalents calculated in such way was compared with that measured with Hawk. LET spectra measured with Liulin and Hawk were compared for each ion at several points behind binary filters along the Brag curve. Good agreement was observed for some configurations; for

  5. An Intercomparison of 10 Atmospheric Model Dynamical Cores

    NASA Astrophysics Data System (ADS)

    Jablonowski, C.; Lauritzen, P. H.; Taylor, M. A.; Nair, R. D.

    2008-12-01

    The poster introduces an idealized test suite for the dynamical cores of Atmospheric General Circulation Models (GCMs) and presents results of the broadest dynamical core intercomparison project ever conducted to date. The intercomparison project was held at the National Center for Atmospheric Research (NCAR), Boulder, in June 2008. It was part of the NCAR Advanced Study Program's Summer Colloquium that not only surveyed the latest developments in numerical methods for dynamical cores but also hosted 10 modeling groups, key lecturers and 40 students for a two-week time period. The participating models represent a wide spectrum of numerical approaches and computational grids like latitude-longitude grids, Gaussian, icosahedral and cubed-sphere meshes. The comparison reveals new insights into the characteristics of the model simulations which include the diffusion and conservation properties. These were assessed via six deterministic dynamical core test cases run by the student group. The test hierarchy is now suggested as the starting point for a standard dynamical core test suite and serves as a launch pad for an even broader community driven dynamical core intercomparison experiment.

  6. EARLINET instrument intercomparison campaigns: overview on strategy and results

    NASA Astrophysics Data System (ADS)

    Wandinger, U.; Freudenthaler, V.; Baars, H.; Amodeo, A.; Engelmann, R.; Mattis, I.; Groß, S.; Pappalardo, G.; Giunta, A.; D'Amico, G.; Chaikovsky, A.; Osipenko, F.; Slesar, A.; Nicolae, D.; Belegante, L.; Talianu, C.; Serikov, I.; Linné, H.; Jansen, F.; Apituley, A.; Wilson, K. M.; de Graaf, M.; Trickl, T.; Giehl, H.; Adam, M.; Comerón, A.; Muñoz, C.; Rocadenbosch, F.; Sicard, M.; Tomás, S.; Lange, D.; Kumar, D.; Pujadas, M.; Molero, F.; Fernández, A. J.; Alados-Arboledas, L.; Bravo-Aranda, J. A.; Navas-Guzmán, F.; Guerrero-Rascado, J. L.; Granados-Muñoz, M. J.; Preißler, J.; Wagner, F.; Gausa, M.; Grigorov, I.; Stoyanov, D.; Iarlori, M.; Rizi, V.; Spinelli, N.; Boselli, A.; Wang, X.; Lo Feudo, T.; Perrone, M. R.; De Tomasi, F.; Burlizzi, P.

    2015-10-01

    This paper introduces the recent EARLINET quality-assurance efforts at instrument level. Within two dedicated campaigns and five single-site intercomparison activities 21 EARLINET systems from 18 EARLINET stations were intercompared between 2009 and 2013. A comprehensive strategy for campaign setup and data evaluation has been established. Eleven systems from nine EARLINET stations participated in the EARLINET Lidar Intercomparison 2009 (EARLI09). In this campaign, three reference systems were qualified which served as traveling standards thereafter. EARLINET systems from nine other stations have been compared against these reference systems since 2009. We present and discuss comparisons at signal and at product level from all campaigns for more than 100 individual measurement channels at the wavelengths of 355, 387, 532 and 607 nm. It is shown that in most cases a very good agreement of the compared systems with the respective reference is obtained. Mean signal deviations in pre-defined height ranges are typically below ±2 %. Particle backscatter and extinction coefficients agree within ±2 × 10-4 km-1 sr-1 and ± 0.01 km-1, respectively, in most cases. For systems or channels that showed larger discrepancies, an in-depth analysis of deficiences was performed and technical solutions and upgrades were proposed and realized. The intercomparisons have reinforced the confidence in the EARLINET data quality and allowed us to draw conclusions on necessary system improvements for some instruments and to identify major challenges that need to be tackled in the future.

  7. EARLINET instrument intercomparison campaigns: overview on strategy and results

    NASA Astrophysics Data System (ADS)

    Wandinger, Ulla; Freudenthaler, Volker; Baars, Holger; Amodeo, Aldo; Engelmann, Ronny; Mattis, Ina; Groß, Silke; Pappalardo, Gelsomina; Giunta, Aldo; D'Amico, Giuseppe; Chaikovsky, Anatoli; Osipenko, Fiodor; Slesar, Alexander; Nicolae, Doina; Belegante, Livio; Talianu, Camelia; Serikov, Ilya; Linné, Holger; Jansen, Friedhelm; Apituley, Arnoud; Wilson, Keith M.; de Graaf, Martin; Trickl, Thomas; Giehl, Helmut; Adam, Mariana; Comerón, Adolfo; Muñoz-Porcar, Constantino; Rocadenbosch, Francesc; Sicard, Michaël; Tomás, Sergio; Lange, Diego; Kumar, Dhiraj; Pujadas, Manuel; Molero, Francisco; Fernández, Alfonso J.; Alados-Arboledas, Lucas; Bravo-Aranda, Juan Antonio; Navas-Guzmán, Francisco; Guerrero-Rascado, Juan Luis; José Granados-Muñoz, María; Preißler, Jana; Wagner, Frank; Gausa, Michael; Grigorov, Ivan; Stoyanov, Dimitar; Iarlori, Marco; Rizi, Vincenco; Spinelli, Nicola; Boselli, Antonella; Wang, Xuan; Lo Feudo, Teresa; Perrone, Maria Rita; De Tomasi, Ferdinando; Burlizzi, Pasquale

    2016-03-01

    This paper introduces the recent European Aerosol Research Lidar Network (EARLINET) quality-assurance efforts at instrument level. Within two dedicated campaigns and five single-site intercomparison activities, 21 EARLINET systems from 18 EARLINET stations were intercompared between 2009 and 2013. A comprehensive strategy for campaign setup and data evaluation has been established. Eleven systems from nine EARLINET stations participated in the EARLINET Lidar Intercomparison 2009 (EARLI09). In this campaign, three reference systems were qualified which served as traveling standards thereafter. EARLINET systems from nine other stations have been compared against these reference systems since 2009. We present and discuss comparisons at signal and at product level from all campaigns for more than 100 individual measurement channels at the wavelengths of 355, 387, 532, and 607 nm. It is shown that in most cases, a very good agreement of the compared systems with the respective reference is obtained. Mean signal deviations in predefined height ranges are typically below ±2 %. Particle backscatter and extinction coefficients agree within ±2 × 10-4 km-1 sr-1 and ± 0.01 km-1, respectively, in most cases. For systems or channels that showed larger discrepancies, an in-depth analysis of deficiencies was performed and technical solutions and upgrades were proposed and realized. The intercomparisons have reinforced confidence in the EARLINET data quality and allowed us to draw conclusions on necessary system improvements for some instruments and to identify major challenges that need to be tackled in the future.

  8. SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENT.

    PubMed

    Rojo, A; Puerta, N; Gossio, S; Gómez Parada, I; Cruz Suarez, R; López, E; Medina, C; Lastra Boylan, J; Pinheiro Ramos, M; Mora Ramírez, E; Alves Dos Reis, A; Yánez, H; Rubio, J; Vironneau Janicek, L; Somarriba Vanegas, F; Puerta Ortiz, J; Salas Ramírez, M; López Bejerano, G; da Silva, T; Miri Oliveira, C; Terán, M; Alfaro, M; García, T; Angeles, A; Duré Romero, E; Farias de Lima, F

    2016-09-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers.

  9. The Project for Intercomparison of Land-surface Parameterization Schemes

    NASA Technical Reports Server (NTRS)

    Henderson-Sellers, A.; Yang, Z.-L.; Dickinson, R. E.

    1993-01-01

    The Project for Intercomparison of Land-surface Parameterization Schemes (PILPS) is described and the first stage science plan outlined. PILPS is a project designed to improve the parameterization of the continental surface, especially the hydrological, energy, momentum, and carbon exchanges with the atmosphere. The PILPS Science Plan incorporates enhanced documentation, comparison, and validation of continental surface parameterization schemes by community participation. Potential participants include code developers, code users, and those who can provide datasets for validation and who have expertise of value in this exercise. PILPS is an important activity because existing intercomparisons, although piecemeal, demonstrate that there are significant differences in the formulation of individual processes in the available land surface schemes. These differences are comparable to other recognized differences among current global climate models such as cloud and convection parameterizations. It is also clear that too few sensitivity studies have been undertaken with the result that there is not yet enough information to indicate which simplifications or omissions are important for the near-surface continental climate, hydrology, and biogeochemistry. PILPS emphasizes sensitivity studies with and intercomparisons of existing land surface codes and the development of areally extensive datasets for their testing and validation.

  10. Ground-based intercomparison of nitric acid measurement techniques

    NASA Astrophysics Data System (ADS)

    Fehsenfeld, Fred C.; Huey, L. Greg; Sueper, Donna T.; Norton, Richard B.; Williams, Eric J.; Eisele, Fred L.; Mauldin, R. Lee; Tanner, David J.

    1998-02-01

    An informal intercomparison of gas-phase nitric acid (HNO3) measuring techniques was carried out. The intercomparison involved two new chemical ionization mass spectrometers (CIMSs) that have been developed for the measurement of HNO3 along with an older, more established filter pack (FP) technique. The filter pack was composed of a teflon prefilter which collected aerosols followed by a nylon filter which collected the gas-phase HNO3. The study was carried out during the late winter and early spring of 1996 at a site located on the western edge of the Denver metropolitan area. Throughout the study the two CIMS techniques were in general agreement. However, under certain conditions the HNO3 levels obtained from the nylon filter of the FP gave values for the gas-phase concentration of HNO3 that were somewhat higher than that recorded by the two CIMS systems. The formation of ammonium nitrate (NH4NO3) containing aerosols is common during the colder months in this area. An analysis of these results suggests that the HNO3 collected by the nylon filter in the FP suffers an interference associated with the disproportionation of NH4NO3 from aerosols containing that compound that were initially collected on the teflon prefilter. This problem with the FP technique has been suggested from results obtained in previous intercomparisons.

  11. A soil sampling intercomparison exercise for the ALMERA network.

    PubMed

    Belli, Maria; de Zorzi, Paolo; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas

    2009-11-01

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a "reference site", aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  12. Inter-comparison between AIRS and IASI through Retrieved Parameters

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Larar, Allen M.; Smith, William L.; Taylor, Jonathan P.; Schluessel, Peter; Strow, L. Larrabee; Mango, Steve

    2008-01-01

    A State-of-the-art retrieval algorithm dealing with all-weather conditions has been applied to satellite/aircraft instruments retrieving cloud/surface and atmospheric conditions. High quality retrievals have been achieved from IASI data. Surface, cloud, and atmospheric structure and variation are well captured by IASI measurements and/or retrievals. The same retrieval algorithm is also applied to AIRS for retrieval inter-comparison. Both AIRS and IASI have a similar FOV size but AIRS has a higher horizontal resolution. AIRS data can be interpolated to IASI horizontal resolution for inter-comparison at the same geophysical locations, however a temporal variation between AIRS and IASI observations need to be considered. JAIVEx has employed aircraft to obtain the atmospheric variation filling the temporal gap between two satellites. First results show that both AIRS and IASI have a very similar vertical resolving power, atmospheric conditions are well captured by both instruments, and radiances are well calibrated. AIRS data shown in retrievals (e.g., surface emissivity and moisture) have a relatively higher noise level. Since the this type of retrieval is very sensitive to its radiance quality, retrieval products inter-comparison is an effective way to identify/compare their radiance quality, in terms of a combination of spectral resolution and noise level, and to assess instrument performance. Additional validation analyses are needed to provide more-definitive conclusions.

  13. SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENT.

    PubMed

    Rojo, A; Puerta, N; Gossio, S; Gómez Parada, I; Cruz Suarez, R; López, E; Medina, C; Lastra Boylan, J; Pinheiro Ramos, M; Mora Ramírez, E; Alves Dos Reis, A; Yánez, H; Rubio, J; Vironneau Janicek, L; Somarriba Vanegas, F; Puerta Ortiz, J; Salas Ramírez, M; López Bejerano, G; da Silva, T; Miri Oliveira, C; Terán, M; Alfaro, M; García, T; Angeles, A; Duré Romero, E; Farias de Lima, F

    2016-09-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers. PMID:26503854

  14. Thermal drift reduction with multiple bias current for MOSFET dosimeters.

    PubMed

    Carvajal, M A; Martínez-Olmos, A; Morales, D P; Lopez-Villanueva, J A; Lallena, A M; Palma, A J

    2011-06-21

    New thermal compensation methods suitable for p-channel MOSFET (pMOS) dosimeters with the usual dose readout procedure based on a constant drain current are presented. Measuring the source-drain voltage shifts for two or three different drain currents and knowing the value of the zero-temperature coefficient drain current, I(ZTC), the thermal drift of source-drain or threshold voltages can be significantly reduced. Analytical expressions for the thermal compensation have been theoretically deduced on the basis of a linear dependence on temperature of the parameters involved. The proposed thermal modelling has been experimentally proven. These methods have been applied to a group of ten commercial pMOS transistors (3N163). The thermal coefficients of the source-drain voltage and the threshold voltage were reduced from -3.0 mV  °C(-1), in the worst case, down to -70 µV  °C(-1). This means a thermal drift of -2.4 mGy  °C(-1) for the dosimeter. When analysing the thermal drifts of all the studied transistors, in the temperature range from 19 to 36 °C, uncertainty was obtained in the threshold voltage due to a thermal drift of ±9 mGy (2 SD), a commonly acceptable value in most radiotherapy treatments. The procedures described herein provide thermal drift reduction comparable to that of other technological or numerical strategies, but can be used in a very simple and low-cost dosimetry sensor. PMID:21606552

  15. Thermal drift reduction with multiple bias current for MOSFET dosimeters

    NASA Astrophysics Data System (ADS)

    Carvajal, M. A.; Martínez-Olmos, A.; Morales, D. P.; Lopez-Villanueva, J. A.; Lallena, A. M.; Palma, A. J.

    2011-06-01

    New thermal compensation methods suitable for p-channel MOSFET (pMOS) dosimeters with the usual dose readout procedure based on a constant drain current are presented. Measuring the source-drain voltage shifts for two or three different drain currents and knowing the value of the zero-temperature coefficient drain current, IZTC, the thermal drift of source-drain or threshold voltages can be significantly reduced. Analytical expressions for the thermal compensation have been theoretically deduced on the basis of a linear dependence on temperature of the parameters involved. The proposed thermal modelling has been experimentally proven. These methods have been applied to a group of ten commercial pMOS transistors (3N163). The thermal coefficients of the source-drain voltage and the threshold voltage were reduced from -3.0 mV °C-1, in the worst case, down to -70 µV °C-1. This means a thermal drift of -2.4 mGy °C-1 for the dosimeter. When analysing the thermal drifts of all the studied transistors, in the temperature range from 19 to 36 °C, uncertainty was obtained in the threshold voltage due to a thermal drift of ±9mGy (2 SD), a commonly acceptable value in most radiotherapy treatments. The procedures described herein provide thermal drift reduction comparable to that of other technological or numerical strategies, but can be used in a very simple and low-cost dosimetry sensor.

  16. Calibration factors for the SNOOPY NP-100 neutron dosimeter

    NASA Astrophysics Data System (ADS)

    Moscu, D. F.; McNeill, F. E.; Chase, J.

    2007-10-01

    Within CANDU nuclear power facilities, only a small fraction of workers are exposed to neutron radiation. For these individuals, roughly 4.5% of the total radiation equivalent dose is the result of exposure to neutrons. When this figure is considered across all workers receiving external exposure of any kind, only 0.25% of the total radiation equivalent dose is the result of exposure to neutrons. At many facilities, the NP-100 neutron dosimeter, manufactured by Canberra Industries Incorporated, is employed in both direct and indirect dosimetry methods. Also known as "SNOOPY", these detectors undergo calibration, which results in a calibration factor relating the neutron count rate to the ambient dose equivalent rate, using a standard Am-Be neutron source. Using measurements presented in a technical note, readings from the dosimeter for six different neutron fields in six source-detector orientations were used, to determine a calibration factor for each of these sources. The calibration factor depends on the neutron energy spectrum and the radiation weighting factor to link neutron fluence to equivalent dose. Although the neutron energy spectra measured in the CANDU workplace are quite different than that of the Am-Be calibration source, the calibration factor remains constant - within acceptable limits - regardless of the neutron source used in the calibration; for the specified calibration orientation and current radiation weighting factors. However, changing the value of the radiation weighting factors would result in changes to the calibration factor. In the event of changes to the radiation weighting factors, it will be necessary to assess whether a change to the calibration process or resulting calibration factor is warranted.

  17. Development of a novel UV indicator and dosimeter film.

    PubMed

    Mills, Andrew; Lee, Soo-Keun; Sheridan, Martin

    2005-07-01

    A novel UV indicator is described, comprising nanocrystalline particles of titania dispersed in a film of a polymer, hydroxyl ethyl cellulose (HEC), containing: a mild reducing agent, triethanolamine (TEOA) and a redox indicator, methylene blue (MB). The UV indicator film is blue-coloured in the absence of UV light and loses colour upon exposure to UV light, attaining within a few min a steady-state degree of bleaching that can provide a measure of the irradiance of the incident light. The original blue colour of the film returns once the source of UV light is removed. The spectral characteristics of a typical UV indicator film, and its components, are discussed and the UV-absorbing action of the titania particles highlighted. From the measured %bleaching undergone by a typical UV indicator as a function of light irradiance the indicator appears fully bleached, within 7 min, by a UV irradiance of 3 mW cm(-2) or greater. The mechanism by which the UV indicator works is described. The reversible nature of the UV indicator is removed by covering a typical UV indicator with a thin, largely oxygen impermeable, polymer film, such as the regenerated cellulose found in Sellotape. The product is a UV dosimeter, the response of which is related to the intensity and duration of the incident UV light, as well as the amount of titania in the film. A typical UV dosimeter film is fully bleached by 250 mJ cm(-2) of UV light. The possible use of these novel indicators to measure UV exposure levels, irradiance and dose, is discussed.

  18. Biological UV dosimeters in simulated space irradiation conditions

    NASA Astrophysics Data System (ADS)

    Rontó, G.; Bérces, A.; Fekete, A.; Kovács, G.; Lammer, H.

    For the measurement of the harmful biological effect of solar UV radiation bacteriophage T7 and polycrystalline uracil dosimeters were used. For terrestrial dosimetric purposes bacteriophage T7 has been applied in solution, while uracil in the form of thin layers. For space irradiation dosimetry the uracil, phage T7-DNA and bacteriophage T7 thin layer samples were prepared in vacuum tightly closed sandwich forms covered either by calciumfluoride or quartz windows. The experimental conditions tested correspond to the conditions planned in the EXPOSE facility: the samples were surrounded by nitrogen atmosphere at various humidities, their vacuum stability was tested in the vacuum chamber of the Institute of Space Research,, Graz. All kinds of the thin film samples have been stored in an atmosphere containing Nitrogen and Hidrogen, in quality control no change in the structure of them has been found. To attenuate the high extraterrestrial irradiance neutral filters of 0.5 and 1.0 optical densities have been tested. Irradiation of the samples has been performed with various UV sources: solar simulator, low pressure Mercury lamp, Deuterium lamp. Dose-effect functions have been determined using for the evaluation spectrophotometry in the characteristic UV range, HPLC of photoproducts, PCR of two different primer sequences of phage T7-DNA. Photoproduct formation kinetics was followed by the saturation level of uracil thin layer. Attenuation ability of the neutral filters was controlled with low pressure Mercury lamp by the exposure necessary for saturation of uracil dosimeters. A three and tenfold increase in the exposure was found respectively, while the influence of spectral composition of the irradiation source was tested using Deuterium lamp supplied with Ca F2 and quartz filters respectively. A doubling of the irradiance was necessary for the saturation of uracil with quartz filter.

  19. Accident Flying Squad

    PubMed Central

    Snook, Roger

    1972-01-01

    This paper describes the organization, evaluation, and costing of an independently financed and operated accident flying squad. 132 accidents involving 302 casualties were attended, six deaths were prevented, medical treatment contributed to the survival of a further four, and the condition or comfort of many other casualties was improved. The calls in which survival was influenced were evenly distributed throughout the three-and-a-half-year survey and seven of the 10 so aided were over 16 and under 30 years of age, all 10 being in the working age group. The time taken to provide the service was not excessive and the expense when compared with the overall saving was very small. The scheme was seen to be equally suitable for basing on hospital or general practice or both, and working as an integrated team with the ambulance service. The use of specialized transport was found to be unnecessary. Other benefits of the scheme included use of the experience of attending accidents to ensure relevant and realistic training for emergency service personnel, and an appreciation of the effect of ambulance design on the patient. ImagesFIG. 1FIG. 4 PMID:5069642

  20. Daily variation of radiation dose rate after the Fukushima Nuclear Accident

    NASA Astrophysics Data System (ADS)

    Yamauchi, Masatoshi

    2015-04-01

    After the radioactive contamination of the lands from the Fukushima Nuclear Power Plant accident, the radiation dose rates observed by the dosimeters often shows daily variations, at different local times at different places or time. These variations are caused by different reasons: the temperature-dependent characteristics of the dosimeter (instrumental effect), the daily convective wind that lifts up the radioactive small particle on the ground (local effect), and the daily sea-land wind that transports the radioactive small particle from highly contaminated area (regional effect). The last type is most important in understanding the internal dose by air taking. However, while very regular patterns can easily be judged as instrumental effect, variations that strongly depend on the weather conditions are not easily judged. Combining the atmospheric electric field measurement near the ground (potential gradient, PG) with the wind and weather data, some of these unclear cases can be classified into above three reasoning, which will be shown in the presentation. Thus, the PG measurement is important right after any nuclear accidents in the future.

  1. NASA Crew Personal Active Dosimeters (CPADs): Leveraging Novel Terrestrial Personal Radiation Monitoring Capabilities for Space Exploration

    NASA Technical Reports Server (NTRS)

    Leitgab, Martin; Semones, Edward; Lee, Kerry

    2016-01-01

    The NASA Space Radiation Analysis Group (SRAG) is developing novel Crew Personal Active Dosimeters (CAPDs) for upcoming crewed space exploration missions and beyond. To reduce the resource footprint of the project a COTS dosimeter base is used for the development of CPADs. This base was identified from evaluations of existing COTS personal dosimeters against the concept of operations of future crewed missions and tests against detection requirements for radiation characteristic of the space environment. CPADs exploit operations efficiencies from novel features for space flight personal dosimeters such as real-time dose feedback, and autonomous measuring and data transmission capabilities. Preliminary CPAD design, results of radiation testing and aspects of operational integration will be presented.

  2. Measurements of entrance surface dose using a fiber-optic dosimeter in diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Yoo, Wook Jae; Seo, Jeong Ki; Shin, Sang Hun; Han, Ki-Tek; Jeon, Dayeong; Jang, Kyoung Won; Sim, Hyeok In; Lee, Bongsoo; Park, Jang-Yeon

    2013-03-01

    In this study, a fiber-optic dosimeter (FOD) was developed to measure entrance surface dose (ESD) in diagnostic radiology. We measured the scintillating lights in order to obtain ESDs, which changed with the various exposure parameters of a digital radiography (DR) system, such as tube potential, current-time product, focus-surface distance (FSD), and field size, using the fabricated FOD system. From the experimental results, the output light signals of the FOD were similar to the ESDs of the conventional semiconductor dosimeter. In conclusion, we characterized the measured ESDs as functions of exposure parameters by using two different types of dosimeters and demonstrated that the proposed FOD using a plastic scintillating fiber and a plastic optical fiber (POF) makes it possible to measure ESDs in the energy range of diagnostic radiology. From the results of this study, it is anticipated that the FOD will be a useful dosimeter in low-energy photon applications including diagnostic radiology.

  3. Novel composition of polymer gel dosimeters based on N-(Hydroxymethyl)acrylamide for radiation therapy

    NASA Astrophysics Data System (ADS)

    Basfar, Ahmed A.; Moftah, Belal; Rabaeh, Khalid A.; Almousa, Akram A.

    2015-07-01

    A new composition of polymer gel dosimeters is developed based on radiation induced polymerization of N-(Hydroxymethyl)acrylamide (NHMA) for radiotherapy treatment planning. The dosimeters were irradiated by 10 MV photon beam of a medical linear accelerator at a constant dose rate of 600 cGy/min with doses up to 20 Gy. The polymerization occurs and increases with increasing absorbed dose. The dose response of polymer gel dosimeters was studied using nuclear magnetic imaging (NMR) for relaxation rate (R2) of water proton. Dose rate, energy of radiation and the stability of the polymerization after irradiation were investigated. No appreciable effects of these parameters on the performance of the novel gel dosimeters were observed.

  4. [Chernobyl nuclear power plant accident and Tokaimura criticality accident].

    PubMed

    Takada, Jun

    2012-03-01

    It is clear from inspection of historical incidents that the scale of disasters in a nuclear power plant accident is quite low level overwhelmingly compared with a nuclear explosion in nuclear war. Two cities of Hiroshima and Nagasaki were destroyed by nuclear blast with about 20 kt TNT equivalent and then approximately 100,000 people have died respectively. On the other hand, the number of acute death is 30 in the Chernobyl nuclear reactor accident. In this chapter, we review health hazards and doses in two historical nuclear incidents of Chernobyl and Tokaimura criticality accident and then understand the feature of the radiation accident in peaceful utilization of nuclear power.

  5. Characterization of the radiological conditions of the reactor building basement and D-rings through thermoluminescent dosimeter readings

    SciTech Connect

    Peterson, H.K.

    1988-01-01

    The accident at Three Mile Island Unit 2 (TMI-2) nuclear generating station of March 1979 released highly contaminated water to the basement and contaminated steam to other parts of the reactor building. These contaminants produced very significant and distinct radiation sources in the basement area and prevalent, lower magnitude sources throughout the remainder of the building. Radiation surveys performed during the early reactor building entries provided an abundance of data adequate for radiation protection purposes, but attempts to use this data to characterize the source terms failed. The data failed in terms of accuracy and in not being ordered to the point where it could be used successfully for computer modeling. Experience at TMI-2 showed that to obtain survey radiation readings sufficient in number and of quality for source term characterization was not consistent with the as low as reasonably achievable (ALARA) principle. One particular disadvantage of the survey data was that is was not reproducible due to inaccuracies in measurement by health physics personnel and due to instrument variations. To obtain the data required for source term characterization, strings of four-chip Panasonic personnel thermoluminescent dosimeters (TLDs) were used. With these strings, numerous radiation profiles of radiation sources throughout the reactor building were measured with an accuracy that allowed the data to be used for computer modeling and eventual source term identification and quantification.

  6. Flexydos3D: A new deformable anthropomorphic 3D dosimeter readout with optical CT scanning

    NASA Astrophysics Data System (ADS)

    De Deene, Yves; Hill, Robin; Skyt, Peter S.; Booth, Jeremy

    2015-01-01

    A new deformable polydimethylsiloxane (PDMS) based dosimeter is proposed that can be cast in an anthropomorphic shape and that can be used for 3D radiation dosimetry of deformable targets. The new material has additional favorable characteristics as it is tissue equivalent for high-energy photons, easy to make and is non-toxic. In combination with dual wavelength optical scanning, it is a powerful dosimeter for dose verification of image gated or organ tracked radiotherapy with moving and deforming targets.

  7. Water and tissue equivalency of some gel dosimeters for photon energy absorption.

    PubMed

    Un, Adem

    2013-12-01

    The mass energy absorption coefficients,, effective atomic numbers for photon energy absorption, ZPEAeff, and effective electron numbers for photon-energy absorption, NPEAeff, is calculated for 14 polymer gel dosimeter, five gel dosimeter, soft tissue and water, in the energy range from 1 keV to 20 MeV. The ZPEAeff(Gel)/ZPEAeff(Tissue) and NPEAeff(Gel)/NPEAeff (Tissue) are used to evaluate the tissue equivalency.

  8. Performance of KCl:Eu2+ storage phosphor dosimeters for low dose measurements

    PubMed Central

    Li, H. Harold; Hansel, Rachael; Knutson, Nels; Yang, Deshan

    2013-01-01

    Recent research has demonstrated that europium doped potassium chloride (KCl:Eu2+) storage phosphor material has the potential to become the physical foundation of a novel and reusable dosimetry system using either film-like devices or devices similar to thermoluminescent dosimeter (TLD) chips. The purposes of this work are to quantify the performance of KCl:Eu2+ prototype dosimeters for low dose measurements and to demonstrate how it can be incorporated into clinical application for in vivo peripheral dose measurements. Pellet-style KCl:Eu2+ dosimeters, 6 mm in diameter, and 1 mm thick, were fabricated in-house for this study. The dosimeters were read using a laboratory photostimulated luminescence detection system. KCl:Eu2+ prototype storage phosphor dosimeter was capable of measuring a dose-to-water as low as 0.01 cGy from a 6 MV photon beam with a signal-to-noise ratio greater than 6. A pre-readout thermal annealing procedure enabled the dosimeter to be read within an hour post irradiation. After receiving large accumulated doses (~10 kGy), the dosimeters retained linear response in the low dose region with only a 20 percent loss of sensitivity comparing to a fresh sample (zero Gy history). The energy-dependence encountered during low dose peripheral measurements could be accounted for via a single point outside-field calibration per each beam quality. With further development the KCl:Eu2+− based dosimeter could become a versatile and durable dosimetry tool with large dynamic range (sub-cGy to 100 Gy). PMID:23735856

  9. Dosimeter incorporating radiophotoluminescent detectors for thermal neutrons and γ-rays in n-γ fields

    NASA Astrophysics Data System (ADS)

    Salem, Y. O.; Nachab, A.; Roy, C.; Nourreddine, A.

    2016-10-01

    We have developed a dosimeter associating different neutron converters with two radiophotoluminescent detectors to measure thermal neutrons and γ-rays in a mixed n-γ field. Tests show that the H∗(10) and Hp(10) responses to thermal neutrons and γ-rays are linear with detection limits lower than 0.4 mSv. The angular dependence of the dosimeter response is satisfactory and the influence of a phantom on the results is examined.

  10. Aircraft accident survivors as witnesses.

    PubMed

    Dodge, R E

    1983-02-01

    This is a study of the reliability of aircrash survivors as witnesses. Some of their statements are compared to known facts at the time of the crash, including the time of the accident and the weather conditions. Other facts are compared between the survivors, such as the mood of the passengers immediately post-crash. The KLM-Pan Am accident in the Canary Islands is used as the study accident. A suggestion for future use of survivors' statements is tendered.

  11. Small-Field Measurements of 3D Polymer Gel Dosimeters through Optical Computed Tomography

    PubMed Central

    Shih, Cheng-Ting; Lee, Yao-Ting; Wu, Shin-Hua; Yao, Chun-Hsu; Hsieh, Bor-Tsung

    2016-01-01

    With advances in therapeutic instruments and techniques, three-dimensional dose delivery has been widely used in radiotherapy. The verification of dose distribution in a small field becomes critical because of the obvious dose gradient within the field. The study investigates the dose distributions of various field sizes by using NIPAM polymer gel dosimeter. The dosimeter consists of 5% gelatin, 5% monomers, 3% cross linkers, and 5 mM THPC. After irradiation, a 24 to 96 hour delay was applied, and the gel dosimeters were read by a cone beam optical computed tomography (optical CT) scanner. The dose distributions measured by the NIPAM gel dosimeter were compared to the outputs of the treatment planning system using gamma evaluation. For the criteria of 3%/3 mm, the pass rates for 5 × 5, 3 × 3, 2 × 2, 1 × 1, and 0.5 × 0.5 cm2 were as high as 91.7%, 90.7%, 88.2%, 74.8%, and 37.3%, respectively. For the criteria of 5%/5 mm, the gamma pass rates of the 5 × 5, 3 × 3, and 2 × 2 cm2 fields were over 99%. The NIPAM gel dosimeter provides high chemical stability. With cone-beam optical CT readouts, the NIPAM polymer gel dosimeter has potential for clinical dose verification of small-field irradiation. PMID:26974434

  12. Characterization of the chemical stability of irradiated N-isopropylacrylamide gel dosimeter

    NASA Astrophysics Data System (ADS)

    Huang, Y. R.; Hsieh, L. L.; Chang, Y. J.; Wang, T. H.; Hsieh, B. T.

    2013-08-01

    An investigation of the normoxic NIPAM gel dosimeter has been undertaken. The NIPAM gel dosimeter used in the current study was mainly composed of gelatin, NIPAM, N,N‧-methylenebisacrylamide (BIS), and distilled water. This study aims to measure the change in the chemical structure of the NIPAM gel dosimeter after irradiation via the 13C-NMR, 1H-NMR, and Fourier transform Raman (FT-Raman) spectra. The 13C-NMR experimental results show that the C=C bonds of NIPAM and BIS are at 126.74 and 131.62 ppm, respectively. The intensity of the C-C bond of the NIPAM gel dosimeter increases with the absorbed dose, and the dose-intensity curve of the C-C bond is determined by y=0.0506+79.9(1-e0.16x) (R2=0.9997). 1H-NMR and FT-Raman can also effectively determine the positions of the C=C bonds of NIPAM and BIS, and the intensity decreases as the absorbed radiation dose increases. Hence, 13C-NMR, 1H-NMR, and FT-Raman spectrometers can effectively detect the changes in the chemical structure of the polymer gel dosimeter after irradiation and successfully determine the D50 dosage in the NIPAM gel dosimeter.

  13. N-isopropylacrylamide gel dosimeter to evaluate clinical photon beam characteristics.

    PubMed

    Chiu, Chung-Yu; Tsang, Yuk-Wah; Hsieh, Bor-Tsung

    2014-08-01

    The introduction of beam intensity control concept in current radiotherapy techniques has increased treatment planning complexity. Thus, small-field dose measurement has become increasingly vital. Polymer gel dosimetry method is widely studied. It is the only dose measurement tool that provides 3D dose distribution. This study aims to use an N-isopropylacrylamide (NIPAM) gel dosimeter to conduct beam performance measurements of percentage depth dose (PDD), beam flatness, and symmetry for photon beams with field sizes of 3×3 and 4×4 cm(2). Computed tomography scans were used to readout the gel dosimeters. In the PDD measurement, the NIPAM gel dosimeter and Gafchromic™ EBT3 radiochromic film displayed high consistency in the region deeper than the build-up region. The gel dosimeter dose profile had 3% lower flatness and symmetry measurement at 5 cm depth for different fields compared with that of the Gafchromic™ EBT3 film. During gamma evaluation under 3%/3 mm dose difference/distance-to-agreement standard, the pass rates of the polymer gel dosimeter to the TPS and EBT3 film were both higher than 96%. Given that the gel is tissue equivalent, it did not exhibit the energy dependence problems of radiochromic films. Therefore, the practical use of NIPAM polymer gel dosimeters is enhanced in clinical dose verification. PMID:24836904

  14. Small-Field Measurements of 3D Polymer Gel Dosimeters through Optical Computed Tomography.

    PubMed

    Shih, Tian-Yu; Wu, Jay; Shih, Cheng-Ting; Lee, Yao-Ting; Wu, Shin-Hua; Yao, Chun-Hsu; Hsieh, Bor-Tsung

    2016-01-01

    With advances in therapeutic instruments and techniques, three-dimensional dose delivery has been widely used in radiotherapy. The verification of dose distribution in a small field becomes critical because of the obvious dose gradient within the field. The study investigates the dose distributions of various field sizes by using NIPAM polymer gel dosimeter. The dosimeter consists of 5% gelatin, 5% monomers, 3% cross linkers, and 5 mM THPC. After irradiation, a 24 to 96 hour delay was applied, and the gel dosimeters were read by a cone beam optical computed tomography (optical CT) scanner. The dose distributions measured by the NIPAM gel dosimeter were compared to the outputs of the treatment planning system using gamma evaluation. For the criteria of 3%/3 mm, the pass rates for 5 × 5, 3 × 3, 2 × 2, 1 × 1, and 0.5 × 0.5 cm2 were as high as 91.7%, 90.7%, 88.2%, 74.8%, and 37.3%, respectively. For the criteria of 5%/5 mm, the gamma pass rates of the 5 × 5, 3 × 3, and 2 × 2 cm2 fields were over 99%. The NIPAM gel dosimeter provides high chemical stability. With cone-beam optical CT readouts, the NIPAM polymer gel dosimeter has potential for clinical dose verification of small-field irradiation. PMID:26974434

  15. Small-Field Measurements of 3D Polymer Gel Dosimeters through Optical Computed Tomography.

    PubMed

    Shih, Tian-Yu; Wu, Jay; Shih, Cheng-Ting; Lee, Yao-Ting; Wu, Shin-Hua; Yao, Chun-Hsu; Hsieh, Bor-Tsung

    2016-01-01

    With advances in therapeutic instruments and techniques, three-dimensional dose delivery has been widely used in radiotherapy. The verification of dose distribution in a small field becomes critical because of the obvious dose gradient within the field. The study investigates the dose distributions of various field sizes by using NIPAM polymer gel dosimeter. The dosimeter consists of 5% gelatin, 5% monomers, 3% cross linkers, and 5 mM THPC. After irradiation, a 24 to 96 hour delay was applied, and the gel dosimeters were read by a cone beam optical computed tomography (optical CT) scanner. The dose distributions measured by the NIPAM gel dosimeter were compared to the outputs of the treatment planning system using gamma evaluation. For the criteria of 3%/3 mm, the pass rates for 5 × 5, 3 × 3, 2 × 2, 1 × 1, and 0.5 × 0.5 cm2 were as high as 91.7%, 90.7%, 88.2%, 74.8%, and 37.3%, respectively. For the criteria of 5%/5 mm, the gamma pass rates of the 5 × 5, 3 × 3, and 2 × 2 cm2 fields were over 99%. The NIPAM gel dosimeter provides high chemical stability. With cone-beam optical CT readouts, the NIPAM polymer gel dosimeter has potential for clinical dose verification of small-field irradiation.

  16. Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

    SciTech Connect

    Hyer, Daniel E.; Fisher, Ryan F.; Hintenlang, David E.

    2009-05-15

    This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

  17. The thermoluminescence study of epoxy based LiF:Mg,Cu,P dosimeters

    NASA Astrophysics Data System (ADS)

    Rahangdale, S. R.; Wankhede, S. P.; Kadam, Sonal; Dhabekar, Bhushan. S.; Palikundwar, U. A.; Moharil, S. V.

    2016-05-01

    The LiF:Mg,Cu,P phosphor is the most investigated phosphor in radiation dosimetry. Results on thermoluminescence of the epoxy based LiF:Mg,Cu,P dosimeters irradiated with gamma radiations are presented and compared with results of LiF:Mg,Cu,P powder. The glow curve structure of both LiF powder and dosimeter are same and only difference is found in the glow curve peak temperature. The LiF dosimeters were made from the 5012A and 5012B epoxy. The dosimeters had a mass of about 18 mg, 5.0 mm diameter and 0.5 mm thickness. The sensitivity variation of the dosimeters for exposure to 60Co gamma rays at different angles of incidence of the radiation is found to be within 4%. Its minimum detectable dose is about 3020 µGy. The epoxy based dosimeters withstand different environment and it can be used with general TL reader without need of any special design due to its small size and plane surface.

  18. Characterization of a new radiochromic three-dimensional dosimeter

    PubMed Central

    Guo, P. Y.; Adamovics, J. A.; Oldham, M.

    2006-01-01

    The development of intensity-modulated radiotherapy (IMRT) has created a clear need for a dosimeter that can accurately and conveniently measure dose distributions in three dimensions to assure treatment quality. PRESAGE™ is a new three dimensional (3D) dosimetry material consisting of an optically clear polyurethane matrix, containing a leuco dye that exhibits a radiochromic response when exposed to ionizing radiation. A number of potential advantages accrue over other gel dosimeters, including insensitivity to oxygen, radiation induced light absorption contrast rather than scattering contrast, and a solid texture amenable to machining to a variety of shapes and sizes without the requirement of an external container. In this paper, we introduce an efficient method to investigate the basic properties of a 3D dosimetry material that exhibits an optical dose response. The method is applied here to study the key aspects of the optical dose response of PRESAGE™: linearity, dose rate dependency, reproducibility, stability, spectral changes in absorption, and temperature effects. PRESAGE™ was prepared in 1×1×4.5 cm3 optical cuvettes for convenience and was irradiated by both photon and electron beams to different doses, dose rates, and energies. Longer PRESAGE™ columns (2 ×2×13 cm3) were formed without an external container, for measurements of photon and high energy electron depth-dose curves. A linear optical scanning technique was used to detect the depth distribution of radiation induced optical density (OD) change along the PRESAGE™ columns and cuvettes. Measured depth-OD curves were compared with percent depth dose (PDD). Results indicate that PRESAGE™ has a linear optical response to radiation dose (with a root mean square error of ∼1%), little dependency on dose rate (∼2%), high intrabatch reproducibility (<2%), and can be stable (∼2%) during 2 hours to 2 days post irradiation. Accurate PRESAGE™ dosimetry requires temperature control

  19. An investigation of a PRESAGE® in vivo dosimeter for brachytherapy

    NASA Astrophysics Data System (ADS)

    Vidovic, A. K.; Juang, T.; Meltsner, S.; Adamovics, J.; Chino, J.; Steffey, B.; Craciunescu, O.; Oldham, M.

    2014-07-01

    Determining accurate in vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm × 20 mm) tissue equivalent radiochromic dosimeter PRESAGE® in vivo (PRESAGE®-IV) is investigated. Two readout methods of the radiation induced change in optical density (OD) were investigated: (i) volume-averaged readout by spectrophotometer, and (ii) a line profile readout by 2D projection imaging utilizing a high-resolution (50 micron) telecentric optical system. Method (i) is considered the gold standard when applied to PRESAGE® in optical cuvettes. The feasibility of both methods was evaluated by comparison to standard measurements on PRESAGE® in optical cuvettes via spectrophotometer. An end-to-end feasibility study was performed by a side-by-side comparison with TLDs in an 192Ir HDR delivery. 7 and 8 Gy was delivered to PRESAGE®-IV and TLDs attached to the surface of a vaginal cylinder. Known geometry enabled direct comparison of measured dose with a commissioned treatment planning system. A high-resolution readout study under a steep dose gradient region showed 98.9% (5%/1 mm) agreement between PRESAGE®-IV and Gafchromic® EBT2 Film. Spectrometer measurements exhibited a linear dose response between 0-15 Gy with sensitivity of 0.0133 ± 0.0007 ΔOD/(Gy ṡ cm) at the 95% confidence interval. Method (ii) yielded a linear response with sensitivity of 0.0132 ± 0.0006 (ΔOD/Gy), within 2% of method (i). Method (i) has poor spatial resolution due to volume averaging. Method (ii) has higher resolution (˜1 mm) without loss of sensitivity or increased noise. Both readout methods are shown to be feasible. The end-to-end comparison revealed a 2.5% agreement between PRESAGE®-IV and treatment plan in regions of uniform high dose. PRESAGE®-IV shows promise for in vivo dose verification

  20. Validation of an "Intelligent Mouthguard" Single Event Head Impact Dosimeter.

    PubMed

    Bartsch, Adam; Samorezov, Sergey; Benzel, Edward; Miele, Vincent; Brett, Daniel

    2014-11-01

    Dating to Colonel John Paul Stapp MD in 1975, scientists have desired to measure live human head impacts with accuracy and precision. But no instrument exists to accurately and precisely quantify single head impact events. Our goal is to develop a practical single event head impact dosimeter known as "Intelligent Mouthguard" and quantify its performance on the benchtop, in vitro and in vivo. In the Intelligent Mouthguard hardware, limited gyroscope bandwidth requires an algorithm-based correction as a function of impact duration. After we apply gyroscope correction algorithm, Intelligent Mouthguard results at time of CG linear acceleration peak correlate to the Reference Hybrid III within our tested range of pulse durations and impact acceleration profiles in American football and Boxing in vitro tests: American football, IMG=1.00REF-1.1g, R2=0.99; maximum time of peak XYZ component imprecision 3.6g and 370 rad/s2; maximum time of peak azimuth and elevation imprecision 4.8° and 2.9°; maximum average XYZ component temporal imprecision 3.3g and 390 rad/s2. Boxing, IMG=1.00REF-0.9 g, R2=0.99, R2=0.98; maximum time of peak XYZ component imprecision 3.9 g and 390 rad/s2, maximum time of peak azimuth and elevation imprecision 2.9° and 2.1°; average XYZ component temporal imprecision 4.0 g and 440 rad/s2. In vivo Intelligent Mouthguard true positive head impacts from American football players and amateur boxers have temporal characteristics (first harmonic frequency from 35 Hz to 79 Hz) within our tested benchtop (first harmonic frequency<180 Hz) and in vitro (first harmonic frequency<100 Hz) ranges. Our conclusions apply only to situations where the rigid body assumption is valid, sensor-skull coupling is maintained and the ranges of tested parameters and harmonics fall within the boundaries of harmonics validated in vitro. For these situations, Intelligent Mouthguard qualifies as a single event dosimeter in American football and Boxing.

  1. Rear-end accident victims. Importance of understanding the accident.

    PubMed Central

    Sehmer, J. M.

    1993-01-01

    Family physicians regularly treat victims of rear-end vehicle accidents. This article describes how taking a detailed history of the accident and understanding the significance of the physical events is helpful in understanding and anticipating patients' morbidity and clinical course. Eight questions to ask patients are suggested to help physicians understand the severity of injury. PMID:8495140

  2. The agricultural model intercomparison and improvement project (AgMIP): Protocols and pilot studies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a distributed climate-scenario simulation research activity for historical period model intercomparison and future climate change conditions with participation of multiple crop and agricultural economic model groups around the...

  3. Radiation accident grips Goiania

    SciTech Connect

    Roberts, L.

    1987-11-20

    On 13 September two young scavengers in Goiania, Brazil, removed a stainless steel cylinder from a cancer therapy machine in an abandoned clinic, touching off a radiation accident second only to Chernobyl in its severity. On 18 September they sold the cylinder, the size of a 1-gallon paint can, to a scrap dealer for $25. At the junk yard an employee dismantled the cylinder and pried open the platinum capsule inside to reveal a glowing blue salt-like substance - 1400 curies of cesium-137. Fascinated by the luminescent powder, several people took it home with them. Some children reportedly rubbed in on their bodies like carnival glitter - an eerie image of how wrong things can go when vigilance over radioactive materials lapses. In all, 244 people in Goiania, a city of 1 million in central Brazil, were contaminated. The eventual toll, in terms of cancer or genetic defects, cannot yet be estimated. Parts of the city are cordoned off as radiation teams continue washing down buildings and scooping up radioactive soil. The government is also grappling with the political fallout from the accident.

  4. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.

    PubMed

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-03-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter.

  5. Development of a fiber-optic dosimeter based on modified direct measurement for real-time dosimetry during radiation diagnosis

    NASA Astrophysics Data System (ADS)

    Yoo, W. J.; Shin, S. H.; Jeon, D.; Han, K.-T.; Hong, S.; Kim, S. G.; Cho, S.; Lee, B.

    2013-09-01

    For applying modified direct measurement, we developed a fiber-optic dosimeter (FOD) with two dosimeter probes to infer the entrance surface dose (ESD) at the center of an x-ray beam field without the obstruction of radiation imaging. The dosimeter probe of the FOD was fabricated by coupling a plastic scintillating fiber to a plastic optical fiber. Under varying exposure parameters, we measured the scintillating light signals using two dosimeter probes, which were placed at the center and the edge of the beam field, respectively, and compared the results with the absorbed doses obtained using a conventional semiconductor dosimeter. Various correlations between the two dosimeter probes according to the exposure parameters were obtained for measuring ESD using a new modified direct measurement approach during a medical imaging task.

  6. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect

    PubMed Central

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-01-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter. PMID:25618136

  7. Global Intercomparison of 12 Land Surface Heat Flux Estimates

    NASA Technical Reports Server (NTRS)

    Jimenez, C.; Prigent, C.; Mueller, B.; Seneviratne, S. I.; McCabe, M. F.; Wood, E. F.; Rossow, W. B.; Balsamo, G.; Betts, A. K.; Dirmeyer, P. A.; Fisher, J. B.; Jung, M.; Kanamitsu, M.; Reichle, R. H.; Reichstein, M.; Rodell, M.; Sheffield, J.; Tu, K.; Wang, K.

    2011-01-01

    A global intercomparison of 12 monthly mean land surface heat flux products for the period 1993-1995 is presented. The intercomparison includes some of the first emerging global satellite-based products (developed at Paris Observatory, Max Planck Institute for Biogeochemistry, University of California Berkeley, University of Maryland, and Princeton University) and examples of fluxes produced by reanalyses (ERA-Interim, MERRA, NCEP-DOE) and off-line land surface models (GSWP-2, GLDAS CLM/ Mosaic/Noah). An intercomparison of the global latent heat flux (Q(sub le)) annual means shows a spread of approx 20 W/sq m (all-product global average of approx 45 W/sq m). A similar spread is observed for the sensible (Q(sub h)) and net radiative (R(sub n)) fluxes. In general, the products correlate well with each other, helped by the large seasonal variability and common forcing data for some of the products. Expected spatial distributions related to the major climatic regimes and geographical features are reproduced by all products. Nevertheless, large Q(sub le)and Q(sub h) absolute differences are also observed. The fluxes were spatially averaged for 10 vegetation classes. The larger Q(sub le) differences were observed for the rain forest but, when normalized by mean fluxes, the differences were comparable to other classes. In general, the correlations between Q(sub le) and R(sub n) were higher for the satellite-based products compared with the reanalyses and off-line models. The fluxes were also averaged for 10 selected basins. The seasonality was generally well captured by all products, but large differences in the flux partitioning were observed for some products and basins.

  8. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: A phantom study

    PubMed Central

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V.; Hagan, Michael; Anscher, Mitchell

    2011-01-01

    Purpose: To evaluate both the Calypso Systems’ (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal–oxide–semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters’ reading accuracy in the presence of wireless electromagnetic transponders inside a phantom.Methods: A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with∕without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with∕without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit.Results: Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum

  9. Climate Model Intercomparisons: Preparing for the Next Phase

    NASA Astrophysics Data System (ADS)

    Meehl, Gerald A.; Moss, Richard; Taylor, Karl E.; Eyring, Veronika; Stouffer, Ronald J.; Bony, Sandrine; Stevens, Bjorn

    2014-03-01

    Since 1995, the Coupled Model Intercomparison Project (CMIP) has coordinated climate model experiments involving multiple international modeling teams. Through CMIP, climate modelers and scientists from around the world have analyzed and compared state-of-the-art climate model simulations to gain insights into the processes, mechanisms, and consequences of climate variability and climate change. This has led to a better understanding of past, present, and future climate, and CMIP model experiments have routinely been the basis for future climate change assessments made by the Intergovernmental Panel on Climate Change (IPCC) [e.g., IPCC, 2013, and references therein].

  10. An intercomparison of hydrological network-design technologies

    USGS Publications Warehouse

    Moss, M.E.; Tasker, Gary D.

    1991-01-01

    Two network-design technologies are compared by random sub-sampling of actual streamflow data. The technologies Network Analysis for Regional Information (NARI) and Network Analysis Using Generalized Least Squares (NAUGLS), have a common objective, viz. to maximize regional information within a limited budget and time horizon. The data used for intercomparison are from a network of 146 streamgauges in the central part of the USA. In general, the results for the illustrative example indicate that the NAUGLS method conveys more information than the NARI method to the network designer interested in maximizing regional information about mean annual flows with a limited budget. -Authors

  11. Interdisciplinary Intercomparison of Black Carbon Analysis in Soil and Sediment

    NASA Astrophysics Data System (ADS)

    Schmidt, Michael W. I.; Masiello, Caroline A.

    2007-08-01

    Analysis and Characterization of Black Carbon in the Environment, Vienna, Austria, 18-19 April 2007 Last April, a symposium was held to discuss new aspects of the rapidly growing field of research focusing on black carbon in soil, sediment, and the atmosphere. About 70 scientists attended the 2-day session during the European Geosciences Union General Assembly, in Vienna. Part of this symposium included a workshop on chemical reference materials, where results of an interdisciplinary intercomparison of black carbon (BC) measurements in different environmental matrices were released.

  12. Slovenian-Romanian bilateral intercomparison on tritium samples.

    PubMed

    Glavič-Cindro, D; Varlam, C; Faurescu, D; Vagner, I; Logar, J Kožar

    2014-05-01

    A Slovenian laboratory from the Jožef Stefan Institute (JSI) and a Romanian laboratory from the National Research and Development Institute for Cryogenics and Isotopic Technologies (ICIT) performed bilateral intercomparisons of tritium determination in environmental samples. On the basis of the results, the measurement and analysis methods were compared. Comparability and traceability were confirmed with the results from international radioactivity proficiency test exercises organized by IAEA and NPL where both laboratories participated. New knowledge gained leads to harmonized, precise and traceable results of low level tritium environmental samples measurements.

  13. An intuitive visualisation of intercomparison results applied to the KCDB.

    PubMed

    Pommé, S

    2006-01-01

    A simple and intuitive graphical method is presented for producing a summary overview of experimental results of a common measurand, e.g. in the frame of an intercomparison. The PomPlots display (relative) deviations of individual results from the consensus value on the horizontal axis and (relative) uncertainties on the vertical axis. The z-scores, z=1, 2 and 3, are represented by diagonal lines, creating the aspect of a pyramidal structure. The most accurate and precise measurement results should be situated close to the top of the pyramid. The plots are used to visualise data from the BIPM key comparison database on primary radioactivity measurements.

  14. The August 1986 through February 1988 radon intercomparisons at EML

    SciTech Connect

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1988-10-01

    In this report, we summarize the results of the eleventh through fourteenth (August 1986, February 1987, July 1987, February 1988) radon intercomparison exercises sponsored by the Environmental Measurements Laboratory. Thirty-six groups including US federal facilities, and national and state laboratories participated in these exercises. The results indicate that the majority of the participants' results were within +-25% of the nominal value at /sup 222/Rn concentrations ranging from 12 to 65 pCi L/sup -1/. Two common difficulties, calculation errors and scintillation cell leakage, are discussed in terms of good practice. 5 refs.

  15. Feasibility Study of Glass Dosimeter for In Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

    SciTech Connect

    Rah, Jeong-Eun; Oh, Do Hoon; Kim, Jong Won; Kim, Dae-Hyun; Suh, Tae-Suk; Ji, Young Hoon; Shin, Dongho; Lee, Se Byeong; Kim, Dae Yong; Park, Sung Yong

    2012-10-01

    Purpose: To evaluate the suitability of the GD-301 glass dosimeter for in vivo dose verification in proton therapy. Methods and Materials: The glass dosimeter was analyzed for its dosimetrics characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stairlike holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurements, we compared the glass dosimeter and thermoluminescent dosimeter (TLD) dose measurements using a cylindrical phantom. We investigated the feasibility of the glass dosimeter for the measurement of dose distributions near the superficial region for proton therapy plans with a varying separation between the target volume and the surface of 6 patients. Results and Discussion: Uniformity was within 1.5%. The dose-response has good linearity. Dose-rate, fading, and energy dependence were found to be within 3%. The beam profile measured using the glass dosimeter was in good agreement with the profile obtained from the ionization chamber. Depth-dose distributions in nonmodulated and modulated proton beams obtained with the glass dosimeter were estimated to be within 3%, which was lower than those with the ionization chamber. In the phantom study, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the glass dosimeter was within 5%. With in vivo dosimetry, the calculated surface doses overestimated measurements by 4%-16% using glass dosimeter and TLD. Conclusion: It is recommended that bolus be added for these clinical cases. We also believe that the glass dosimeter has considerable potential for use with in vivo patient proton dosimetry.

  16. A small active dosimeter for applications in space

    NASA Astrophysics Data System (ADS)

    Ritter, Birgit; Maršálek, Karel; Berger, Thomas; Burmeister, Sönke; Reitz, Günther; Heber, Bernd

    2014-06-01

    The radiation field in low Earth orbits (LEO) differs significantly from the radiation environment on Earth's surface. Exposures are by far higher and pose an additional health risk for astronauts. Continuous monitoring is therefore a necessary task in the frame of radiation protection measures. A small battery-driven active dosimeter telescope based on silicon detectors meeting the requirements for LEO applications has been developed. The instrument, the Mobile Dosimetric Telescope (MDT), is designed to measure the absorbed dose rate and the linear energy transfer (LET) spectra. From the latter the mean quality factor of the radiation field can be derived and hence an estimate of the dose equivalent as a measure of the exposure. The calibration of the device is done using radioactive isotopes and heavy ions. Fragmentation products of heavy ions are used to show the ability of the MDT to reliably detect energy depositions from high energetic nuclei. Radiation measurements inside aircraft during long distance flights, serving as field tests of the instrument, prove the good performance of the instrument.

  17. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  18. Automated gamma spectrometry and data analysis on radiometric neutron dosimeters

    SciTech Connect

    Matsumoto, W.Y.

    1983-01-01

    An automated gamma-ray spectrometry system was designed and implemented by the Westinghouse Hanford Company at the Hanford Engineering Development Laboratory (HEDL) to analyze radiometric neutron dosimeters. Unattended, automatic, 24 hour/day, 7 day/week operation with online data analysis and mainframe-computer compatible magnetic tape output are system features. The system was used to analyze most of the 4000-plus radiometric monitors (RM's) from extensive reactor characterization tests during startup and initial operation of th Fast Flux Test Facility (FFTF). The FFTF, operated by HEDL for the Department of Energy, incorporates a 400 MW(th) sodium-cooled fast reactor. Aumomated system hardware consists of a high purity germanium detector, a computerized multichannel analyzer data acquisition system (Nuclear Data, Inc. Model 6620) with two dual 2.5 Mbyte magnetic disk drives plus two 10.5 inch reel magnetic tape units for mass storage of programs/data and an automated Sample Changer-Positioner (ASC-P) run with a programmable controller. The ASC-P has a 200 sample capacity and 12 calibrated counting (analysis) positions ranging from 6 inches (15 cm) to more than 20 feet (6.1 m) from the detector. The system software was programmed in Fortran at HEDL, except for the Nuclear Data, Inc. Peak Search and Analysis Program and Disk Operating System (MIDAS+).

  19. Thermoluminescent dosimeters for low dose X-ray measurements.

    PubMed

    Fernández, S Del Sol; García-Salcedo, R; Sánchez-Guzmán, D; Ramírez-Rodríguez, G; Gaona, E; de León-Alfaro, M A; Rivera-Montalvo, T

    2016-01-01

    The response of TLD-100, CaSO4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm(2) at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO4:Dy showed a linearity from 0.1 to 60 mGy.

  20. Study of Fricke gel dosimeter response for different gel quality

    NASA Astrophysics Data System (ADS)

    Cavinato, C. C.; Campos, L. L.

    2010-11-01

    The Fricke xylenol gel (FXG) dosimeter has been studied for application in radiotherapy because it is capable of to measure the spatial distribution of radiation doses. The dosimetry is based on the oxidation of ferrous (Fe2+) to ferric (Fe3+) ions radiation induced, related to the radiation dose. The gel material usually employed is the 300 Bloom gelatin, which is imported and very expensive in Brazil. Aiming to analyze the viability of to use a locally produced and low cost gel material, in this work the spectrophotometric responses of FXG solutions prepared using 270 Bloom gelatin commercially available and 300 Bloom gelatin imported were compared. The absorption spectra of solutions prepared with 5% by weight 270 and 300 Bloom gelatins non-irradiated and irradiated with 60Co gamma radiation in the dose range between 0.5 and 100 Gy were analysed, the dose-response curves were evaluated and the useful dose range was established. The obtained results indicate that the FXG solution prepared with 270 Bloom gelatin presents good performance, similar to that presented by the FXG solution prepared with 300 Bloom gelatin and its use can be recommended owing to the low cost and the availability in local market.

  1. Electron Beam Quality Determination Through Fricke Xylenol Gel Dosimeter

    SciTech Connect

    Petchevist, P. C. D.; Moreira, M. V.; Almeida, A. de

    2009-03-10

    According to the IAEA TRS-398 protocol, a parallel plate ionization chamber is recommended to be used in electron dosimetry. The important dosimetric parameters such as R{sub 100} and R{sub 50}, inferred from the percentage depth dose (PDD) curve, allow to obtain the electron beam average energy at the water phantom surface (material equivalent to the soft tissue). In this work, a chemical dosimeter based on the Fe(II) to Fe(III) oxidation was used to obtain the average energies from electrons beams (from nominal energies of 5, 8 and 10 MeV) and related parameters of R{sub 100}, R{sub 50} and z{sub ref}. These energies obtained through the Fricke Xylenol Gel (FXG) were compared to those with a parallel plate ionization chamber, following the cited protocol, which showed no significant differences. From these measurements one can conclude the FXG applicability for R{sub 100}, R{sub 50} and electron beam average energy determination.

  2. Thermoluminescent dosimeters for low dose X-ray measurements.

    PubMed

    Fernández, S Del Sol; García-Salcedo, R; Sánchez-Guzmán, D; Ramírez-Rodríguez, G; Gaona, E; de León-Alfaro, M A; Rivera-Montalvo, T

    2016-01-01

    The response of TLD-100, CaSO4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm(2) at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO4:Dy showed a linearity from 0.1 to 60 mGy. PMID:26609683

  3. German aircraft accident statistics, 1930

    NASA Technical Reports Server (NTRS)

    Weitzmann, Ludwig

    1932-01-01

    The investigation of all serious accidents, involving technical defects in the airplane or engine, is undertaken by the D.V.L. in conjunction with the imperial traffic minister and other interested parties. All accidents not clearly explained in the reports are subsequently cleared up.

  4. First Responders and Criticality Accidents

    SciTech Connect

    Valerie L. Putman; Douglas M. Minnema

    2005-11-01

    Nuclear criticality accident descriptions typically include, but do not focus on, information useful to first responders. We studied these accidents, noting characteristics to help (1) first responders prepare for such an event and (2) emergency drill planners develop appropriate simulations for training. We also provide recommendations to help people prepare for such events in the future.

  5. Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose response using different monomers

    NASA Astrophysics Data System (ADS)

    Senden, R. J.; DeJean, P.; McAuley, K. B.; Schreiner, L. J.

    2006-07-01

    In this work, three new polymer gel dosimeter recipes were investigated that may be more suitable for widespread applications than polyacrylamide gel dosimeters, since the extremely toxic acrylamide has been replaced with the less harmful monomers N-isopropylacrylamide (NIPAM), diacetone acrylamide and N-vinylformamide. The new gel dosimeters studied contained gelatin (5 wt%), monomer (3 wt%), N,N'-methylene-bis-acrylamide crosslinker (3 wt%) and tetrakis (hydroxymethyl) phosphonium chloride antioxidant (10 mM). The NMR response (R2) of the dosimeters was analysed for conditions of varying dose, dose rate, time post-irradiation, and temperature during irradiation and scanning. It was shown that the dose-response behaviour of the NIPAM/Bis gel dosimeter is comparable to that of normoxic polyacrylamide gel (PAGAT) in terms of high dose-sensitivity and low dependence on dose rate and irradiation temperature, within the ranges considered. The dose-response (R2) of NIPAM/Bis appears to be linear over a greater dose range than the PAGAT gel dosimeter. The effects of time post-irradiation (temporal instability) and temperature during NMR scanning on the R2 response were more significant for NIPAM/Bis dosimeters. Diacetone acrylamide and N-vinylformamide gel dosimeters possessed considerably lower dose-sensitivities. The optical dose-response, measured in terms of the attenuation coefficient for each polymer gel dosimeter, showed potential for the use of optical imaging techniques in future studies.

  6. Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose-response using different monomers.

    PubMed

    Senden, R J; De Jean, P; McAuley, K B; Schreiner, L J

    2006-07-21

    In this work, three new polymer gel dosimeter recipes were investigated that may be more suitable for widespread applications than polyacrylamide gel dosimeters, since the extremely toxic acrylamide has been replaced with the less harmful monomers N-isopropylacrylamide (NIPAM), diacetone acrylamide and N-vinylformamide. The new gel dosimeters studied contained gelatin (5 wt%), monomer (3 wt%), N,N'-methylene-bis-acrylamide crosslinker (3 wt%) and tetrakis (hydroxymethyl) phosphonium chloride antioxidant (10 mM). The NMR response (R2) of the dosimeters was analysed for conditions of varying dose, dose rate, time post-irradiation, and temperature during irradiation and scanning. It was shown that the dose-response behaviour of the NIPAM/Bis gel dosimeter is comparable to that of normoxic polyacrylamide gel (PAGAT) in terms of high dose-sensitivity and low dependence on dose rate and irradiation temperature, within the ranges considered. The dose-response (R2) of NIPAM/Bis appears to be linear over a greater dose range than the PAGAT gel dosimeter. The effects of time post-irradiation (temporal instability) and temperature during NMR scanning on the R2 response were more significant for NIPAM/Bis dosimeters. Diacetone acrylamide and N-vinylformamide gel dosimeters possessed considerably lower dose-sensitivities. The optical dose-response, measured in terms of the attenuation coefficient for each polymer gel dosimeter, showed potential for the use of optical imaging techniques in future studies. PMID:16825731

  7. SU-E-T-368: Effect of a Strong Magnetic Field On Select Radiation Dosimeters

    SciTech Connect

    Mathis, M; Wen, Z; Tailor, R; Sawakuchi, G; Flint, D; Beddar, S; Ibbott, G

    2014-06-01

    Purpose: To determine the effect of a strong magnetic field on TLD-100, OSLD (Al{sub 2}O{sub 2}:C), and PRESAGE dosimetry devices. This study will help to determine which types of dosimeters can be used for quality assurance and in-vivo dosimetry measurements in a magnetic resonance imaginglinear accelerator (MRI-linac) system. Methods: The dosimeters were separated into two categories which were either exposed or not exposed to a strong magnetic field. In each category a set of dosimeters was irradiated with 0, 2, or 6 Gy. To expose the dosimeters to a magnetic field the samples in that category were place in a Bruker small animal magnetic resonance scanner at a field strength slightly greater than 2.5 T for at least 1 hour preirradiation and at least 1 hour post-irradiation. Irradiations were performed with a 6 MV x-ray beam from a Varian TrueBeam linac with 10×10 cm{sup 2} field at a 600 MU/min dose rate. The samples that received no radiation dose were used as control detectors. Results: The readouts of the dosimeters which were not exposed to a strong magnetic field were compared with the measurements of the dosimetry devices which were exposed to a magnetic field. No significant differences (less than 2% difference) in the performance of TLD, OSLD, or PRESAGE dosimeters due to exposure to a strong magnetic field were observed. Conclusion: Exposure to a strong magnetic field before and after irradiation does not appear to change the dosimetric properties of TLD, OSLD, or PRESAGE which indicates that these dosimeters have potential for use in quality assurance and in-vivo dosimetry in a MRI-linac. We plan to further test the effect of magnetic fields on these devices by irradiating them in the presence of a magnetic fields similar to those produced by a MRI-linac system. Elekta-MD Anderson Cancer Center Research Agreement.

  8. Field calibrations of a long-term UV dosimeter for aquatic UVB exposures.

    PubMed

    Schouten, P W; Parisi, A V; Turnbull, D J

    2008-05-29

    Various methodologies using a wide range of measurement systems have been employed previously in order to determine the amount of UV that could be incident upon various aquatic organisms in a number of different aquatic locales. Broadband meters and spectroradiometers have been employed extensively to take underwater measurements. However, these measurement campaigns are limited by the fact that radiometric equipment requires a human controller, constant power supply and regular calibrations and corrections in order to function properly. Dosimetric measurements have also been made underwater using two distinct types of dosimeter. The first type based on a synthetic chemical, like polysulphone, and the second type based on a biological matter, such as a DNA sample. The studies made using biological dosimeters have displayed very good results, however the time and skill necessary to make these types of dosimeters can outweigh their usefulness. The chemical dosimeters are easier to make and have also provided useable data, but only for short periods of exposure, usually no more than a day. Previous research has shown that Poly (2,6-dimethyl-1,4-phenylene oxide) (PPO) has excellent potential for use as a long-term underwater solar UVB dosimeter. However, there is no documented methodology on how to properly calibrate the PPO dosimeter for water-based measurements and it has yet to be trialled in an outdoors marine environment, either real or simulated. This manuscript shows that calibrations obtained in air can not be transferred to calibrations made in water, calibrations made in one type of water can be employed for another type of water, but only within a certain range of spectral transmission and calibrations made at different depths in the same water type are interchangeable. It was also discovered that changing solar zenith angle had an effect upon calibration data. This research addressed these issues by formulating and developing a calibration methodology

  9. Dual calibrated dosimeter for simultaneous measurements of erythemal and vitamin D effective solar ultraviolet radiation.

    PubMed

    Wainwright, L; Parisi, A V; Downs, N

    2016-04-01

    A miniaturized ultraviolet radiation (UV) dosimeter based on polyphenylene oxide (PPO) has been dual calibrated for both erythemal and vitamin D effective exposures (UVB 280 - 320 nm) over extended periods up to five days. Optimal human health requires a balanced amount of UVB exposure as both too much and too little have different but serious potential health consequences. Dosimetry is an established method of measuring specific UV exposures to an object or subject. PPO dosimeters have previously been used to measure the erythemally effective UV exposure. An extension of this use is to dual calibrate the miniaturized dosimeter which will also enable measurement of vitamin D effective exposures. By calibration to the erythemal and vitamin D effective action spectra, PPO dosimeters were able to record both types of biologically effective exposure as both are active within the UVB waveband. Dose response tests were conducted in each season by exposure to solar UV with the corresponding dual calibrations made for each season. The calibration provided an R(2) of 0.95-0.99 for erythemal UV and an R(2) of 0.99 for vitamin D effective UV. The successful outcome of this testing has established that PPO is suitable for use as a long term, dual calibrated dosimeter provided the film is seasonally calibrated. This enables one dosimeter to provide two sets of exposure results. The combination of dual calibration and the long term exposure potential of PPO makes the PPO dosimeter more versatile and increases the scope of UV field research on erythemal UV and vitamin D effective UV in the future. PMID:26878218

  10. Field calibrations of a long-term UV dosimeter for aquatic UVB exposures.

    PubMed

    Schouten, P W; Parisi, A V; Turnbull, D J

    2008-05-29

    Various methodologies using a wide range of measurement systems have been employed previously in order to determine the amount of UV that could be incident upon various aquatic organisms in a number of different aquatic locales. Broadband meters and spectroradiometers have been employed extensively to take underwater measurements. However, these measurement campaigns are limited by the fact that radiometric equipment requires a human controller, constant power supply and regular calibrations and corrections in order to function properly. Dosimetric measurements have also been made underwater using two distinct types of dosimeter. The first type based on a synthetic chemical, like polysulphone, and the second type based on a biological matter, such as a DNA sample. The studies made using biological dosimeters have displayed very good results, however the time and skill necessary to make these types of dosimeters can outweigh their usefulness. The chemical dosimeters are easier to make and have also provided useable data, but only for short periods of exposure, usually no more than a day. Previous research has shown that Poly (2,6-dimethyl-1,4-phenylene oxide) (PPO) has excellent potential for use as a long-term underwater solar UVB dosimeter. However, there is no documented methodology on how to properly calibrate the PPO dosimeter for water-based measurements and it has yet to be trialled in an outdoors marine environment, either real or simulated. This manuscript shows that calibrations obtained in air can not be transferred to calibrations made in water, calibrations made in one type of water can be employed for another type of water, but only within a certain range of spectral transmission and calibrations made at different depths in the same water type are interchangeable. It was also discovered that changing solar zenith angle had an effect upon calibration data. This research addressed these issues by formulating and developing a calibration methodology

  11. Study of a non-diffusing radiochromic gel dosimeter for 3D radiation dose imaging

    NASA Astrophysics Data System (ADS)

    Marsden, Craig Michael

    2000-12-01

    This thesis investigates the potential of a new radiation gel dosimeter, based on nitro-blue tetrazolium (NBTZ) suspended in a gelatin mold. Unlike all Fricke based gel dosimeters this dosimeter does not suffer from diffusive loss of image stability. Images are obtained by an optical tomography method. Nitro blue tetrazolium is a common biological indicator that when irradiated in an aqueous medium undergoes reduction to a highly colored formazan, which has an absorbance maximum at 525nm. Tetrazolium is water soluble while the formazan product is insoluble. The formazan product sticks to the gelatin matrix and the dose image is maintained for three months. Methods to maximize the sensitivity of the system were evaluated. It was found that a chemical detergent, Triton X-100, in combination with sodium formate, increased the dosimeter sensitivity significantly. An initial G-value of formazan production for a dosimeter composed of 1mM NBTZ, gelatin, and water was on the order of 0.2. The addition of Triton and formate produced a G-value in excess of 5.0. The effects of NBTZ, triton, formate, and gel concentration were all investigated. All the gels provided linear dose vs. absorbance plots for doses from 0 to >100 Gy. It was determined that gel concentration had minimal if any effect on sensitivity. Sensitivity increased slightly with increasing NBTZ concentration. Triton and formate individually and together provided moderate to large increases in dosimeter sensitivity. The dosimeter described in this work can provide stable 3D radiation dose images for all modalities of radiation therapy equipment. Methods to increase sensitivity are developed and discussed.

  12. Transport aircraft accident dynamics

    NASA Technical Reports Server (NTRS)

    Cominsky, A.

    1982-01-01

    A study was carried out of 112 impact survivable jet transport aircraft accidents (world wide) of 27,700 kg (60,000 lb.) aircraft and up extending over the last 20 years. This study centered on the effect of impact and the follow-on events on aircraft structures and was confined to the approach, landing and takeoff segments of the flight. The significant characteristics, frequency of occurrence and the effect on the occupants of the above data base were studied and categorized with a view to establishing typical impact scenarios for use as a basis of verifying the effectiveness of potential safety concepts. Studies were also carried out of related subjects such as: (1) assessment of advanced materials; (2) human tolerance to impact; (3) merit functions for safety concepts; and (4) impact analysis and test methods.

  13. The Continuous Intercomparison of Radiation Codes (CIRC): Phase I Cases

    NASA Technical Reports Server (NTRS)

    Oreopoulos, Lazaros; Mlawer, Eli; Delamere, Jennifer; Shippert, Timothy; Turner, David D.; Miller, Mark A.; Minnis, Patrick; Clough, Shepard; Barker, Howard; Ellingson, Robert

    2007-01-01

    CIRC aspires to be the successor to ICRCCM (Intercomparison of Radiation Codes in Climate Models). It is envisioned as an evolving and regularly updated reference source for GCM-type radiative transfer (RT) code evaluation with the principle goal to contribute in the improvement of RT parameterizations. CIRC is jointly endorsed by DOE's Atmospheric Radiation Measurement (ARM) program and the GEWEX Radiation Panel (GRP). CIRC's goal is to provide test cases for which GCM RT algorithms should be performing at their best, i.e, well characterized clear-sky and homogeneous, overcast cloudy cases. What distinguishes CIRC from previous intercomparisons is that its pool of cases is based on observed datasets. The bulk of atmospheric and surface input as well as radiative fluxes come from ARM observations as documented in the Broadband Heating Rate Profile (BBHRP) product. BBHRP also provides reference calculations from AER's RRTM RT algorithms that can be used to select the most optimal set of cases and to provide a first-order estimate of our ability to achieve radiative flux closure given the limitations in our knowledge of the atmospheric state.

  14. The T-REX valley wind intercomparison project

    SciTech Connect

    Schmidli, J; Billings, B J; Burton, R; Chow, F K; De Wekker, S; Doyle, J D; Grubisic, V; Holt, T R; Jiang, Q; Lundquist, K A; Ross, A N; Sheridan, P; Vosper, S; Whiteman, C D; Wyszogrodzki, A A; Zaengl, G; Zhong, S

    2008-08-07

    An accurate simulation of the evolution of the atmospheric boundary layer is very important, as the evolution of the boundary layer sets the stage for many weather phenomena, such as deep convection. Over mountain areas the evolution of the boundary layer is particularly complex, due to the nonlinear interaction between boundary layer turbulence and thermally-induced mesoscale wind systems, such as the slope and valley winds. As the horizontal resolution of operational forecasts progresses to finer and finer resolution, more and more of the thermally-induced mesoscale wind systems can be explicitly resolved, and it is very timely to document the current state-of-the-art of mesoscale models at simulating the coupled evolution of the mountain boundary layer and the valley wind system. In this paper we present an intercomparison of valley wind simulations for an idealized valley-plain configuration using eight state-of-the-art mesoscale models with a grid spacing of 1 km. Different sets of three-dimensional simulations are used to explore the effects of varying model dynamical cores and physical parameterizations. This intercomparison project was conducted as part of the Terrain-induced Rotor Experiment (T-REX; Grubisic et al., 2008).

  15. First national intercomparison of solar ultraviolet radiometers in Italy

    NASA Astrophysics Data System (ADS)

    Diémoz, H.; Siani, A. M.; Casale, G. R.; di Sarra, A.; Serpillo, B.; Petkov, B.; Scaglione, S.; Bonino, A.; Facta, S.; Fedele, F.; Grifoni, D.; Verdi, L.; Zipoli, G.

    2011-05-01

    A blind intercomparison of ground-based ultraviolet (UV) instruments has been organized for the first time in Italy. The campaign was coordinated by the Environmental Protection Agency of Aosta Valley (ARPA Valle d'Aosta) and took place in Saint-Christophe (45.8° N, 7.4° E, 570 m a.s.l.), in the Alpine region, from 8 to 23 June 2010. It involved 8 institutions, 10 broadband radiometers, 2 filter radiometers and 2 spectroradiometers. Synchronized measurements of downward global solar UV irradiance at the ground were collected and the raw series were then individually processed by the respective operators on the basis of their own procedures and calibration data. The comparison was performed in terms of global solar UV Index and integrated UV-A irradiance against a well-calibrated double monochromator spectroradiometer as reference. An improved algorithm for comparing broadband data and spectra has been developed. For some instruments, we found average deviations ranging from -16 % up to 20 % relative to the reference and diurnal variations as large as 15 % even in clear days. Remarkable deviations also arose from instruments recently in operation and never involved in field intercomparison.

  16. First national intercomparison of solar ultraviolet radiometers in Italy

    NASA Astrophysics Data System (ADS)

    Diémoz, H.; Siani, A. M.; Casale, G. R.; di Sarra, A.; Serpillo, B.; Petkov, B.; Scaglione, S.; Bonino, A.; Facta, S.; Fedele, F.; Grifoni, D.; Verdi, L.; Zipoli, G.

    2011-08-01

    A blind intercomparison of ground-based ultraviolet (UV) instruments has been organized for the first time in Italy. The campaign was coordinated by the Environmental Protection Agency of Aosta Valley (ARPA Valle d'Aosta) and took place in Saint-Christophe (45.8° N, 7.4° E, 570 m a.s.l.), in the Alpine region, from 8 to 23 June 2010. It involved 8 institutions, 10 broadband radiometers, 2 filter radiometers and 2 spectroradiometers. Synchronized measurements of downward global solar UV irradiance at the ground were collected and the raw series were then individually processed by the respective operators on the base of their own procedures and calibration data. A radiative transfer model was successfully applied as an interpretative tool. The input parameters and output results are described in detail. The comparison was performed in terms of global solar UV Index and integrated UV-A irradiance against a well-calibrated double monochromator spectroradiometer as reference. An improved algorithm for comparing broadband data and spectra has been developed and is discussed in detail. For some instruments, we found average deviations ranging from -16 % up to 20 % relative to the reference and diurnal variations as large as 15 % even in clear days. Remarkable deviations were found for the instruments calibrated in the manufacturers' facilities and never involved in field intercomparison. Finally, some recommendations to the UV operators based on the campaign results are proposed.

  17. Results of the Marine Ice Sheet Model Intercomparison Project, MISMIP

    NASA Astrophysics Data System (ADS)

    Pattyn, F.; Schoof, C.; Perichon, L.; Hindmarsh, R. C. A.; Bueler, E.; de Fleurian, B.; Durand, G.; Gagliardini, O.; Gladstone, R.; Goldberg, D.; Gudmundsson, G. H.; Lee, V.; Nick, F. M.; Payne, A. J.; Pollard, D.; Rybak, O.; Saito, F.; Vieli, A.

    2012-01-01

    Predictions of marine ice-sheet behaviour require models that are able to robustly simulate grounding line migration. We present results of an intercomparison exercise for marine ice-sheet models. Verification is effected by comparison with approximate analytical solutions for flux across the grounding line using simplified geometrical configurations (no lateral variations, no effects of lateral buttressing). Unique steady-state grounding line positions exist for ice sheets on a downward sloping bed, while hysteresis occurs across an overdeepened bed, and stable steady state grounding line positions only occur on the downward-sloping sections. Models based on the shallow ice approximation, which does not resolve extensional stresses, do not reproduce the approximate analytical results unless appropriate parameterizations for ice flux are imposed at the grounding line. For extensional-stress resolving "shelfy stream" models, differences between model results were mainly due to the choice of spatial discretization. Moving grid methods were found to be the most accurate at capturing grounding line evolution, since they track the grounding line explicitly. Adaptive mesh refinement can further improve accuracy, including in fixed-grid models that generally perform poorly at coarse resolution. Fixed grid models with nested grid representations of the grounding line are able to generate accurate steady-state positions, but can be inaccurate over transients. Only one full Stokes model was included in the intercomparison, and consequently the accuracy of shelfy stream models as approximations of full Stokes models remains to be determined in detail, especially during transients.

  18. Results of the Marine Ice Sheet Model Intercomparison Project, MISMIP

    NASA Astrophysics Data System (ADS)

    Pattyn, F.; Schoof, C.; Perichon, L.; Hindmarsh, R. C. A.; Bueler, E.; de Fleurian, B.; Durand, G.; Gagliardini, O.; Gladstone, R.; Goldberg, D.; Gudmundsson, G. H.; Huybrechts, P.; Lee, V.; Nick, F. M.; Payne, A. J.; Pollard, D.; Rybak, O.; Saito, F.; Vieli, A.

    2012-05-01

    Predictions of marine ice-sheet behaviour require models that are able to robustly simulate grounding line migration. We present results of an intercomparison exercise for marine ice-sheet models. Verification is effected by comparison with approximate analytical solutions for flux across the grounding line using simplified geometrical configurations (no lateral variations, no effects of lateral buttressing). Unique steady state grounding line positions exist for ice sheets on a downward sloping bed, while hysteresis occurs across an overdeepened bed, and stable steady state grounding line positions only occur on the downward-sloping sections. Models based on the shallow ice approximation, which does not resolve extensional stresses, do not reproduce the approximate analytical results unless appropriate parameterizations for ice flux are imposed at the grounding line. For extensional-stress resolving "shelfy stream" models, differences between model results were mainly due to the choice of spatial discretization. Moving grid methods were found to be the most accurate at capturing grounding line evolution, since they track the grounding line explicitly. Adaptive mesh refinement can further improve accuracy, including fixed grid models that generally perform poorly at coarse resolution. Fixed grid models, with nested grid representations of the grounding line, are able to generate accurate steady state positions, but can be inaccurate over transients. Only one full-Stokes model was included in the intercomparison, and consequently the accuracy of shelfy stream models as approximations of full-Stokes models remains to be determined in detail, especially during transients.

  19. In situ gamma-spectrometry intercomparison exercise in Salzburg, Austria

    NASA Astrophysics Data System (ADS)

    Lettner, H.; Andrasi, A.; Hubmer, A. K.; Lovranich, E.; Steger, F.; Zombori, P.

    1996-02-01

    In situ gamma-spectrometry has become a useful method of assessing the nuclide concentrations of man-made and natural gamma-emitters in the soil. For the quality assurance of the measurements, periodically conducted intercomparison exercises are essential. Therefore exercises were organized in different European countries since 1990, the last one was conducted in Salzburg, Austria in September 1994. The participation of 27 measurement teams from all over Europe emphasizes the importance of the intercomparison. Salzburg was selected because the Province of Salzburg, Austria was among the most heavily contaminated regions outside the former USSR by the Chernobyl fallout. Two different typical sites were selected for the measurements: Site 1 was inside the urban area of Salzburg on intensively used grassland which had not been tilled since the deposition of the fallout. This site is representative for intensively used agricultural regions in the Province of Salzburg. Site 2 was in the mountainous regions of the Hohe Tauern at an elevated altitude of 1600 m, representing the agricultural soil- and contamination conditions of the Alpine regions in the Tauern. The two sites differ significantly in terms of soil characteristics, a crucial parameter for the evaluation of in situ gamma-spectra. The participants used different approaches for the evaluation of the gamma-spectra in terms of considering the depth distribution. In the paper the results from the 24 European teams are presented.

  20. Intercomparisons of AIRS Observations with MERRA Reanalysis and Climate Models

    NASA Astrophysics Data System (ADS)

    Hearty, T. J.; Vollmer, B.; Theobald, M.; Savtchenko, A. K.; Ding, F.; Esfandiari, A. E.; Ostrenga, D.; Bosilovich, M. G.; Fetzer, E.; Tian, B.; Fishbein, E.; Manning, E.; Yue, Q.

    2012-12-01

    We perform intercomparisons among AIRS (Atmospheric Infrared Sounder) observations, MERRA (Modern-Era Retrospective Analysis for Research and Applications) reanalysis, and CMIP5 models. One of the greatest challenges of using satellite observations from Low Earth Orbit (LEO) to evaluate climate models is to account for differences in the sampling. Climate models are sampled on a regular grid with equal increments in time and space while LEO satellite observations are not. Since AIRS is an infrared instrument its sampling is also affected by clouds. Version 6 of the AIRS processing algorithm will have improved accuracy and increased sampling over the Version 5 algorithm. We compare AIRS and MERRA data with identical sampling to assess how well the satellite observations and reanalysis Water Vapor, Temperature, and Clouds agree when they have the same sampling. Since Version 6 of the AIRS processing algorithms also have improved sampling we use MERRA sampled like AIRS to estimate the improvement in the sampling bias between AIRS Version 5 and Version 6 Results. While the uncertainties in the current generation of climate models are larger than the sampling uncertainties, as the models improve more careful intercomparisons will be necessary. Therefore we compare the differences between AIRS observations and CMIP5 Climate Models to assess the significance of the sampling uncertainties.

  1. An overview of sensor calibration inter-comparison and applications

    USGS Publications Warehouse

    Xiong, Xiaoxiong; Cao, Changyong; Chander, Gyanesh

    2010-01-01

    Long-term climate data records (CDR) are often constructed using observations made by multiple Earth observing sensors over a broad range of spectra and a large scale in both time and space. These sensors can be of the same or different types operated on the same or different platforms. They can be developed and built with different technologies and are likely operated over different time spans. It has been known that the uncertainty of climate models and data records depends not only on the calibration quality (accuracy and stability) of individual sensors, but also on their calibration consistency across instruments and platforms. Therefore, sensor calibration inter-comparison and validation have become increasingly demanding and will continue to play an important role for a better understanding of the science product quality. This paper provides an overview of different methodologies, which have been successfully applied for sensor calibration inter-comparison. Specific examples using different sensors, including MODIS, AVHRR, and ETM+, are presented to illustrate the implementation of these methodologies.

  2. IPRT polarized radiative transfer model intercomparison project - Phase A

    NASA Astrophysics Data System (ADS)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Korkin, Sergey; Ota, Yoshifumi; Labonnote, Laurent C.; Lyapustin, Alexei; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2015-10-01

    The polarization state of electromagnetic radiation scattered by atmospheric particles such as aerosols, cloud droplets, or ice crystals contains much more information about the optical and microphysical properties than the total intensity alone. For this reason an increasing number of polarimetric observations are performed from space, from the ground and from aircraft. Polarized radiative transfer models are required to interpret and analyse these measurements and to develop retrieval algorithms exploiting polarimetric observations. In the last years a large number of new codes have been developed, mostly for specific applications. Benchmark results are available for specific cases, but not for more sophisticated scenarios including polarized surface reflection and multi-layer atmospheres. The International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to fill this gap. This paper presents the results of the first phase A of the IPRT project which includes ten test cases, from simple setups with only one layer and Rayleigh scattering to rather sophisticated setups with a cloud embedded in a standard atmosphere above an ocean surface. All scenarios in the first phase A of the intercomparison project are for a one-dimensional plane-parallel model geometry. The commonly established benchmark results are available at the IPRT website.

  3. The 1994 North American interagency intercomparison of ultraviolet monitoring spectroradiometers

    SciTech Connect

    Thompson, A.; Early, E.A.; DeLuisi, J.

    1997-05-01

    Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the first North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 19--29, 1994 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency, National Science Foundation, Smithsonian Environmental Research Center, and Atmospheric Environment Service, Canada. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp calibrated to operate in the horizontal position. The spectral irradiance responsivity was determined once indoors and twice outdoors, and demonstrated that, while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp, and a simple convolution technique to account for the different bandwidths of the instruments, the measured solar irradiances agreed within 5%.

  4. WOCE 1991 chlorofluorocarbon standard intercomparison report. Data report

    SciTech Connect

    Bullister, J.L.; Menzia, F.; Wisegarver, D.P.

    1993-07-01

    A chlorofluorocarbon (CFC) standard intercomparison study was done among ten laboratories involved in measurements of dissolved and atmospheric CFCs as part of the World Ocean Circulation Experiment (WOCE) and other programs. The goal of the study was to compare CFC calibration scales and to allow CFC data sets collected by the participating groups to be merged together more easily. One cyclinder was distributed to each participating laboratory for analysis and return to PMEL. Within the precision of the analytical techniques used at PMEL, the CFC-11 and CFC-12 concentrations in the cylinders remained uniform throughout the intercomparison exercise. The CFC-113 and carbon tetrachloride content of the cylinders remained relatively uniform in all but one of the cylinders analyzed. The CFC-11 concentrations reported by participating laboratories ranged from 258.8 to 275.6 parts-per-trillion (PPT). The reported CFC-12 concentrations ranged from 487.4 to 503.5 PPT. Two laboratories reported values for CFC-113, and only one laboratory reported a value for carbon tetrachloride. Details of the calibration techniques used by the ten participating laboratories are given in the Appendices of the report.

  5. An intercomparison of in situ gamma-ray spectrometers

    SciTech Connect

    Miller, K.M.; Shebell, P.; Monetti, M.A.

    1998-12-31

    The results of an intercomparison of in situ gamma-ray spectrometers that was held at Brookhaven National Laboratory in the fall of 1997 are presented. Six different organizations participated in this intercomparison which involved simultaneous and sequential co-located field measurements at a site with typical background radiation and another site with elevated {sup 137}Cs concentrations in the soil. These field measurements were supplemented with laboratory-based measurements of point sources at three different energies and two different angles of irradiance. Among the participants, agreement in the field measurements results was generally within 15% of the group mean for each radionuclide. Comparisons to soil sample measurements at the background site show agreement of the group means to within 10% for the various radionuclides present after correcting for the effects of soil moisture. The point source measurement results indicate that the observed differences among groups may be related to systematic errors in their calibrations that result from uncertainty in the activities of the sources used, dissimilarities in the source-detector setup geometry, and inaccuracies in the detector model used in a theoretical calibration.

  6. DOE radiological calibrations intercomparison program: Results of fiscal year 1986

    SciTech Connect

    Cummings, F.M.; Roberson, P.L.; McDonald, J.C.

    1987-05-01

    The Department of Energy Radiological Calibration Intercomparison Program was initiated in January 1986, under the research portion of the DOE Laboratory Accreditation Program. The program operates via the exchange of transfer standards, consisting of instrument sets and standard secondary beta sources. There are two instrument sets and the scheduled use has been staggered such that one set is available for use during each month. One set of secondary standard beta sources is available for use bimonthly. During the 1986 fiscal year, five laboratories used the instrument sets and three laboratories used the beta source set. Results were reported for all the measurements. The average and one standard deviation of the ratios of participant results to Pacific Northwest Laboratory calibration values were 1.12 +- 0.17 for gamma measurements. Those ratios for the gamma measurements varied from 0.98 to 3.06. The larger differences of results from measurements performed at two facilities were directly attributable to unfamiliarity with the intercomparison instruments. The average and one standard deviation of the ratios of participant results to PNL calibration values obtained using the secondary /sup 90/Sr beta source was 1.02 +- 0.05, which is well within measurement uncertainties. The one participant who performed measurements using /sup 147/Pm and /sup 204/Tl sources obtained ratios of 0.68 and 1.11, respectively. No measurements were performed using neutron or x-ray sources.

  7. The characterization of a commercial MOSFET dosimeter system for use in diagnostic x ray.

    PubMed

    Bower, M W; Hintenlang, D E

    1998-08-01

    A commercial patient dose verification system utilizing non-invasive metal oxide semiconductor field effect transistor (MOSFET) dosimeters originally designed for radiotherapy applications has been evaluated for use at diagnostic energy levels. The system features multiple dosimeters that may be used to monitor entrance or exit skin dose and intracavity doses in phantoms in real time. We have characterized both the standard MOSFET dosimeter designed for radiotherapy dose verification and a newly developed "high sensitivity" MOSFET dosimeter designed for lower dose measurements. The sensitivity, linearity, angular response, post-exposure response, and physical characteristics were evaluated. The average sensitivity (free in air, including backscatter) of the radiotherapy MOSFET dosimeters ranged from 3.55 x 10(4) mV per C kg(-1) (9.2 mV R(-1)) to 4.87 x 10(4) mV per C kg(-1) (12.6 mV R(-1)) depending on the energy of the x-ray field. The sensitivity of the "high sensitivity" MOSFET dosimeters ranged from 1.15 x 10(5) mV per C kg(-1) (29.7 mV R(-1)) to 1.38 x 10(5) mV per C kg(-1) (35.7 mV R(-1)) depending on the energy of the x-ray field. The high sensitivity dosimeters demonstrated excellent linearity at high energies (90 and 120 kVp) and acceptable linearity at lower energies (60 kVp). The angular response was significant for free-in-air exposures, as illustrated by the sensitivity differences between the two sides of the dosimeter, but was excellent for measurements within a tissue equivalent cylinder. The post-exposure drift response is a complicated but reproducible function of time. Real-time monitoring requires little if any corrections for the post-exposure drift response. The MOSFET dosimeter system brings some unique capabilities to diagnostic radiology dosimetry including small size, real-time capabilities, nondestructive measurement, good linearity, and a predictable angular response. PMID:9685076

  8. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    SciTech Connect

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.; Kraft, S.; Richter, C.; Zeil, K.; Pawelke, J.

    2012-05-15

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  9. Photofission Analysis for Fissile Dosimeters Dedicated to Reactor Pressure Vessel Surveillance

    NASA Astrophysics Data System (ADS)

    Bourganel, Stéphane; Faucher, Margaux; Thiollay, Nicolas

    2016-02-01

    Fissile dosimeters are commonly used in reactor pressure vessel surveillance programs. In this paper, the photofission contribution is analyzed for in-vessel 237Np and 238U fissile dosimeters in French PWR. The aim is to reassess this contribution using recent tools (the TRIPOLI-4 Monte Carlo code) and latest nuclear data (JEFF3.1.1 and ENDF/B-VII nuclear libraries). To be as exhaustive as possible, this study is carried out for different configurations of fissile dosimeters, irradiated inside different kinds of PWR: 900 MWe, 1300 MWe, and 1450 MWe. Calculation of photofission rate in dosimeters does not present a major problem using the TRIPOLI-4® Monte Carlo code and the coupled neutron-photon simulation mode. However, preliminary studies were necessary to identify the origin of photons responsible of photofissions in dosimeters in relation to the photofission threshold reaction (around 5 MeV). It appears that the main contribution of high enough energy photons generating photofissions is the neutron inelastic scattering in stainless steel reactor structures. By contrast, 137Cs activity calculation is not an easy task since photofission yield data are known with high uncertainty.

  10. FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties

    NASA Astrophysics Data System (ADS)

    De Deene, Y.; Skyt, P. S.; Hil, R.; Booth, J. T.

    2015-02-01

    Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software. A new three dimensional anthropomorphically shaped flexible dosimeter, further called ‘FlexyDos3D’, has been constructed and a new fast optical scanning method has been implemented that enables scanning of irregular shaped dosimeters. The FlexyDos3D phantom can be actuated and deformed during the actual treatment. FlexyDos3D offers the additional advantage that it is easy to fabricate, is non-toxic and can be molded in an arbitrary shape with high geometrical precision. The dosimeter formulation has been optimized in terms of dose sensitivity. The influence of the casting material and oxygen concentration has also been investigated. The radiophysical properties of this new dosimeter are discussed including stability, spatial integrity, temperature dependence of the dosimeter during radiation, readout and storage, dose rate dependence and tissue equivalence. The first authors Y De Deene and P S Skyt made an equivalent contribution to the experimental work presented in this paper.

  11. Eliminating the dose-rate effect in a radiochromic silicone-based 3D dosimeter

    NASA Astrophysics Data System (ADS)

    Høye, E. M.; Balling, P.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Skyt, P. S.

    2015-07-01

    Comprehensive dose verification, such as 3D dosimetry, may be required for safe introduction and use of advanced treatment modalities in radiotherapy. A radiochromic silicone-based 3D dosimetry system has recently been suggested, though its clinical use has so far been limited by a considerable dose-rate dependency of the dose response. In this study we have investigated the dose-rate dependency with respect to the chemical composition of the dosimeter. We found that this dependency was reduced with increasing dye concentration, and the dose response was observed to be identical for dosimeters irradiated with 2 and 6 Gy min-1 at concentrations of 0.26% (w/w) dye and 1% (w/w) dye solvent. Furthermore, for the optimized dosimeter formulation, no dose-rate effect was observed due to the attenuation of the beam fluence with depth. However, the temporal stability of the dose response decreased with dye concentration; the response was reduced by (62  ±  1)% within approximately 20 h upon irradiation, at the optimal chemical composition and storage at room temperature. In conclusion, this study presents a chemical composition for a dose-rate independent silicone dosimeter which has considerably improved the clinical applicability of such dosimeters, but at the cost of a decreased stability.

  12. Undoped and doped poly(tetraphenylbenzidine) as sensitive material for an impedimetric nitrogen dioxide gas dosimeter

    SciTech Connect

    Marr, I.; Moos, R.; Neumann, K.; Thelakkat, M.

    2014-09-29

    This article presents a nitrogen dioxide (NO{sub 2}) detecting gas dosimeter based on poly(tetraphenylbenzidine) poly(TPD) as nitrogen oxide (NO{sub x}) sensitive layer. Gas dosimeters are suitable devices to determine reliably low levels of analytes over a long period of time. During NO{sub x} exposure, the analyte molecules are accumulated irreversibly in the sensing layer of the dosimeter enhancing the conductivity of the hole conducting poly(TPD), which can be measured by impedance spectroscopy. Due to their possibility for low cost production by simple printing techniques and very good physical, photochemical, and electrochemical properties, poly(TPD)s are suitable for application in gas dosimeters operated at room temperature. We studied the effect of doping with a Co(III)-complex in combination with a conducting salt on the dosimeter behavior. Compared to the undoped material, a strong influence of the doping can be observed: the conductivity of the sensing material increases significantly, the noise of the signal decreases and an unwanted recovery of the sensor signal can be prevented, leading to a NO{sub x} detection limit <10 ppm.

  13. Characteristics of a normoxic polymethacrylic acid gel dosimeter for a 72-MeV proton beam

    NASA Astrophysics Data System (ADS)

    Bong, Jihye; Shin, Dongho; Kwon, Soo-Il

    2014-01-01

    The characteristics of a normoxic polymethacrylic acid gel dosimeter for a 72-MeV proton beam were evaluated. A polymer gel dosimeter was synthesized using gelatin, methacrylic acid, hydroquinone, tetrakis(hydroxymethyl) phosphonium chloride, and highly purified distilled water. The dosimeter was manufactured by placement in a polyethylene (PE) container. Irradiated dosimeters were analyzed to determine the transverse relaxation time (T2) using a 1.5-T MRI. A calibration curve was obtained as a function of the absorbed dose. A Bragg curve made by irradiating the gel with mono-energy was compared with the results for a parallel plate ionization chamber. The spread-out Bragg peak (SOBP) range and distal dose fall-off (DDF) were comparatively analyzed by comparing the irradiated gel with a spread-out Bragg peak against with the ion chamber. Lastly, the gel's usefulness as a dosimeter for therapeutic radiation quality assurance was evaluated by obtaining its practical field size, flatness, and symmetry, through comparison of the profiles of the gel and ion chamber.

  14. Applicability of the polyphenylene oxide film dosimeter to high UV exposures in aquatic environments.

    PubMed

    Schouten, P W; Parisi, A V; Turnbull, D J

    2009-09-01

    Previous research has proven that the Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) dosimeter is capable of receiving both in-air and underwater UV exposures that are significantly greater than those of the more commonly used polysulphone dosimeter, within a range of accuracy close to what would be expected of dosimetric measurements made in-air provided that the necessary calibrations are completed correctly by factoring in different atmospheric column ozone levels, SZA ranges, varying water turbidity and DOM levels. However, there is yet to be an investigation detailing the performance of the PPO dosimeter and its ability to measure UV in an actual field environment over an extended period of time. This research aims to bridge this gap in the knowledge by presenting a measurement campaign carried out in two real world aquatic environments and a simulated sea water environment using a batch of PPO dosimeters set at different depths and aligned to a range of different angles and geographical directions by means of attachment to a custom built dosimeter submersible float (DSF) unit over the space of a year at a sub-tropical location. Results obtained from this measurement campaign were used to compute a K(d) value for the sea water in each particular season. These K(d) values where found to be in close agreement to standalone K(d) values derived from results taken using a standard calibrated spectrometer in the same sea water. PMID:19596202

  15. Undoped and doped poly(tetraphenylbenzidine) as sensitive material for an impedimetric nitrogen dioxide gas dosimeter

    NASA Astrophysics Data System (ADS)

    Marr, I.; Neumann, K.; Thelakkat, M.; Moos, R.

    2014-09-01

    This article presents a nitrogen dioxide (NO2) detecting gas dosimeter based on poly(tetraphenylbenzidine) poly(TPD) as nitrogen oxide (NOx) sensitive layer. Gas dosimeters are suitable devices to determine reliably low levels of analytes over a long period of time. During NOx exposure, the analyte molecules are accumulated irreversibly in the sensing layer of the dosimeter enhancing the conductivity of the hole conducting poly(TPD), which can be measured by impedance spectroscopy. Due to their possibility for low cost production by simple printing techniques and very good physical, photochemical, and electrochemical properties, poly(TPD)s are suitable for application in gas dosimeters operated at room temperature. We studied the effect of doping with a Co(III)-complex in combination with a conducting salt on the dosimeter behavior. Compared to the undoped material, a strong influence of the doping can be observed: the conductivity of the sensing material increases significantly, the noise of the signal decreases and an unwanted recovery of the sensor signal can be prevented, leading to a NOx detection limit <10 ppm.

  16. SU-D-213-07: Initial Characterization of a Gel Patch Dosimeter for in Vivo Dosimetry

    SciTech Connect

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2015-06-15

    Purpose: In vivo dosimetry, despite being the most direct method for monitoring the dose delivered during radiation therapy and being recommended by several national and international organizations (AAPM, ICRU, NACP), is underutilized in the clinic due to issues associated with dose sensitivity, feasibility, and cost. Given the increasing complexity of radiation therapy modern treatments, there is a compelling need for a robust, affordable in vivo dosimetry option. In this work we present the initial characterization of a novel gel patch in vivo dosimeter. Methods: DEFGEL (6%T) was used to make 1-cm thick small cylindrical patch dosimeters. The optical density of each dosimeter was read before and after irradiation by an in-house laser densitometer. The dosimeters were irradiated using a Varian Clinac EX linac. Three separate batches of gel patches were used to create dose response curves and evaluate repeatability. The development time of the dosimeter was also evaluated. Results: The dose response of the dosimeter was found to be linear from a range of approximately 1-Gy to 20-Gy, which is a larger window of linearity compared to other in vivo dosimeters. At doses below 1-Gy, the cumulative uncertainties were on the order of the measured data. When compared, the three batches demonstrated repeatability from 1-Gy to approximately 13-Gy, with some variation at higher doses. For doses of >8-Gy, the dosimeter reached full optical density after 4-hours, whereas low doses developed within an hour. Conclusion: Initial results indicate that the gel patch dosimeter is a reliable and simple way to measure a large range of doses, including high doses such as those delivered during hypofractionated treatments (e.g. SBRT or MR-guided radiotherapy). The simple fabrication method for the dosimeter and the use of a laser densitometer would allow for the dosimeter to used and read in-house, cheaply and easily.

  17. A search for novel thermoluminescent radiation dosimeter media.

    PubMed

    Al-Hinai, Khalid H; Benkara Mohd, Nadjima; Rozullyah Zulkepely, Nurul; Md Nor, Roslan; Mohd Amin, Yusoff; Bradley, D A

    2013-12-01

    We describe two example pilot efforts to help define new thermoluminescent dosimeter media. The first concerns ZnS:Mn nanophosphors, prepared by chemical precipitation using zinc and sodium sulfate, doped with manganese sulfate at concentrations varying from 1 to 3mol. The second concerns chemical vapor deposited diamond, produced as a thin film or as amorphous carbon on a single-crystal silicon substrate, each deposited under the same conditions, use being made of the hot filament-chemical vapor deposition (HFCVD) technique. The gas concentrations used were 1% CH4 in 99% H2 and 25% CH4 in 75% H2. Characterization of formations used FESEM, XRD and EDX. The nanophosphors consisted of particles of sizes in the range 85-150nm, the thermoluminescence (TL)-based radiation detection medium giving rise to a single peaked glow curve of maximum yield at a temperature of 250°C at a heating rate of 5°C/s. The TL response increased linearly with radiation dose, ZnS doped to 2mol of Mn being found the most sensitive. Regarding chemical vapor deposited (CVD) carbon, inappreciable TL was found for the resultant ball-like amorphous carbon films, graphite, and the silicon substrate, whereas CVD diamond films showed a promising degree of linearity with dose. For both the ZnS and diamond samples, TL signal fading was appreciable, being some 40% per day for ZnS and>50% per day for CVD films even under storage in the dark at room temperature, making it apparent that there is need to adjust parameters such as the size of nanoparticles.

  18. Reference materials and intercomparison samples available from the Environmental Monitoring Systems Laboratory - Las Vegas

    SciTech Connect

    Kantor, E.J.; Laska, P.R.

    1985-06-01

    Reference materials and intercomparison samples may be obtained by laboratories involved in the analysis of environmental samples containing radioactivity, pesticides, toxic inorganic species, or toxic organic species. These reference materials and intercomparison samples are available from the US Environmental Protection Agency's Quality Assurance Division located at the Environmental Monitoring Systems Laboratory in Las Vegas (EMSL-LV). These materials are useful for incorporation into a laboratory's quality control program for the evaluation of the precision and accuracy of analytical work. Media used for radiation reference materials are pitchblende, Monazite ore, uranium mill tailings, Mancos shale, fly ash, and water spiked with radionuclides. Radioactivity intercomparison samples consist of water, milk, air, urine, and a simulated diet slurry spiked with radionuclides. Media available for toxic organic reference materials are sludge, shale oil, and rag oil, and for intercomparison samples are soil and water. Characterized fly ash, foundry sludge, and river sediment serve as reference materials for toxic inorganics, while spiked soil and water serve as intercomparison samples. Finally, spiked adipose tissue, blood plasma, urine, and water comprise the pesticide intercomparison samples, and, after the disclosure of the true pesticide compositions and concentrations of these samples, the laboratory can use the samples as reference materials. The reference materials are generally available continuously, but the intercomparison samples are distributed on a scheduled basis and in some cases only to certain laboratories. 9 tables.

  19. A review of criticality accidents

    SciTech Connect

    Stratton, W R; Smith, D R

    1989-03-01

    Criticality accidents and the characteristics of prompt power excursions are discussed. Forty-one accidental power transients are reviewed. In each case where available, enough detail is given to help visualize the physical situation, the cause or causes of the accident, the history and characteristics of the transient, the energy release, and the consequences, if any, to personnel and property. Excursions associated with large power reactors are not included in this study, except that some information on the major accident at the Chernobyl reactor in April 1986 is provided in the Appendix. 67 refs., 21 figs., 2 tabs.

  20. [Prevention of bicycle accidents].

    PubMed

    Zwipp, H; Barthel, P; Bönninger, J; Bürkle, H; Hagemeister, C; Hannawald, L; Huhn, R; Kühn, M; Liers, H; Maier, R; Otte, D; Prokop, G; Seeck, A; Sturm, J; Unger, T

    2015-04-01

    For a very precise analysis of all injured bicyclists in Germany it would be important to have definitions for "severely injured", "seriously injured" and "critically injured". By this, e.g., two-thirds of surgically treated bicyclists who are not registered by the police could become available for a general analysis. Elderly bicyclists (> 60 years) are a minority (10 %) but represent a majority (50 %) of all fatalities. They profit most by wearing a helmet and would be less injured by using special bicycle bags, switching on their hearing aids and following all traffic rules. E-bikes are used more and more (145 % more in 2012 vs. 2011) with 600,000 at the end of 2011 and are increasingly involved in accidents but still have a lack of legislation. So even for pedelecs 45 with 500 W and a possible speed of 45 km/h there is still no legislative demand for the use of a protecting helmet. 96 % of all injured cyclists in Germany had more than 0.5 ‰ alcohol in their blood, 86 % more than 1.1 ‰ and 59 % more than 1.7 ‰. Fatalities are seen in 24.2 % of cases without any collision partner. Therefore the ADFC calls for a limit of 1.1 ‰. Some virtual studies conclude that integrated sensors in bicycle helmets which would interact with sensors in cars could prevent collisions or reduce the severity of injury by stopping the cars automatically. Integrated sensors in cars with opening angles of 180° enable about 93 % of all bicyclists to be detected leading to a high rate of injury avoidance and/or mitigation. Hanging lamps reduce with 35 % significantly bicycle accidents for children, traffic education for children and special trainings for elderly bicyclists are also recommended as prevention tools. As long as helmet use for bicyclists in Germany rates only 9 % on average and legislative orders for using a helmet will not be in force in the near future, coming up campaigns seem to be necessary to be promoted by the Deutscher

  1. [Prevention of bicycle accidents].

    PubMed

    Zwipp, H; Barthel, P; Bönninger, J; Bürkle, H; Hagemeister, C; Hannawald, L; Huhn, R; Kühn, M; Liers, H; Maier, R; Otte, D; Prokop, G; Seeck, A; Sturm, J; Unger, T

    2015-04-01

    For a very precise analysis of all injured bicyclists in Germany it would be important to have definitions for "severely injured", "seriously injured" and "critically injured". By this, e.g., two-thirds of surgically treated bicyclists who are not registered by the police could become available for a general analysis. Elderly bicyclists (> 60 years) are a minority (10 %) but represent a majority (50 %) of all fatalities. They profit most by wearing a helmet and would be less injured by using special bicycle bags, switching on their hearing aids and following all traffic rules. E-bikes are used more and more (145 % more in 2012 vs. 2011) with 600,000 at the end of 2011 and are increasingly involved in accidents but still have a lack of legislation. So even for pedelecs 45 with 500 W and a possible speed of 45 km/h there is still no legislative demand for the use of a protecting helmet. 96 % of all injured cyclists in Germany had more than 0.5 ‰ alcohol in their blood, 86 % more than 1.1 ‰ and 59 % more than 1.7 ‰. Fatalities are seen in 24.2 % of cases without any collision partner. Therefore the ADFC calls for a limit of 1.1 ‰. Some virtual studies conclude that integrated sensors in bicycle helmets which would interact with sensors in cars could prevent collisions or reduce the severity of injury by stopping the cars automatically. Integrated sensors in cars with opening angles of 180° enable about 93 % of all bicyclists to be detected leading to a high rate of injury avoidance and/or mitigation. Hanging lamps reduce with 35 % significantly bicycle accidents for children, traffic education for children and special trainings for elderly bicyclists are also recommended as prevention tools. As long as helmet use for bicyclists in Germany rates only 9 % on average and legislative orders for using a helmet will not be in force in the near future, coming up campaigns seem to be necessary to be promoted by the Deutscher

  2. Intercomparison of MAX-DOAS NO2 retrieval algorithms

    NASA Astrophysics Data System (ADS)

    Peters, Enno; Pinardi, Gaia; Bösch, Tim; Wittrock, Folkard; Richter, Andreas; Burrows, John P.; Van Roozendael, Michel; Piters, Ankie; Wagner, Thomas; Drosoglou, Theano; Bais, Alkis; Wang, Shanshan; Saiz-Lopez, Alfonso

    2016-04-01

    Ground-based Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements are a powerful method for monitoring of atmospheric composition in an automated way. The number of instruments and sites operated has been rapidly increasing over the last years. However, integrating the measurements from all these instruments into a consistent data set necessitates careful homogenization of measurements and data retrieval procedures. For this reason, several MAX-DOAS intercomparison campaigns have been carried out in the last years. Mostly, slant columns measured by different instruments and retrieved by different software were intercompared, i.e. observed differences were potentially caused by both, the instrument and/or the retrieval. In contrast, the approach presented here is a pure intercomparison of MAX-DOAS retrievals. In total, 16 international groups and institutes working in the field of MAX-DOAS participated. The work was performed as part of the EU-funded QA4ECV project. The intercomparison exercise is based on data recorded by the IUP-Bremen MAX-DOAS instrument during the MAD-CAT campaign (Multi-Axis DOAS comparison campaign for Aerosols and Trace gases), which was carried out at the Max-Planck-Institute of Chemistry in Mainz, Germany, in summer 2013. Each group participating in the exercise presented here performed MAX-DOAS fits using their own retrieval software but common input (IUP-Bremen spectra, same cross-sections, and same fit settings). The resulting slant columns show in general an excellent agreement (correlation coefficient > 99.9%). Surprisingly, the correlation is substantially smaller when using sequential Fraunhofer reference spectra instead of a noon reference indicating that groups calculate the sequential reference differently. Further differences were found to arise from treatment of the slit function and subsequent convolution of cross-sections as well as from wavelength calibration. The results indicate overall a high

  3. Temperature response of a number of plastic dosimeters for radiation processing

    NASA Astrophysics Data System (ADS)

    Sohrabpour, M.; Kazemi, A. A.; Mousavi, H.; Solati, K.

    1993-10-01

    Various plastic dosemeters are employed for dosimetry control of radiation processing within gamma and electron irradiation facilities. The temperature response of a dosimeter is important when the dose to such a dosimeter is accumulated under varying irradiation temperatures. Such measurements would be significant for proper assessment of the dose for better process control, as well as, performance evaluation of dosimetry systems. In this work we have developed a high current peltier junction temperature controller system for our Gammacell-220. This system has been designed to regulate the operating temperature of the irradiation chamber in the range of 0 to 80 C this system has been applied to measure the temperature response of the red perspex, a local clear PMMA, Gammex, Gammachrome, and Gafchromic dosimeters. The curves of relative performance or variation of the induced optical densities of the above dosemeters versus the irradiation temperature at fixed dose values are obtained.

  4. The effect of chemical stability on the NIPAM gel dosimeter using 1H-NMR

    NASA Astrophysics Data System (ADS)

    Huang, You-Ruei; Hsieh, Ling-Ling; Chang, Yuan-Jen; Hsieh, Bor-Tsung

    2013-06-01

    Radiation-induced chemical changes in the N-isopropylacrylamide (NIPAM) gels used in three-dimensional dosimeters were investigated using 1H-NMR in this study. The experimental results show that the signal from C=C bonds of NIPAM and N,N'-Methylenediacrylamide (BIS) are 5.5 and 6.3 ppm, respectively. The double bonds from the NIPAM and BIS disappeared with half-dose (D50) were about 10.90 Gy ± 0.76 Gy and 10.09 Gy ± 0.29 Gy, respectively. This observation demonstrates that the polymerization rate of BIS is faster than that of the NIPAM monomer. The 1H-NMR can indicate the chemical structure changes of the polymer gel dosimeter after irradiation and successfully determine the D50 in the NIPAM gel dosimeter.

  5. The study of N-isopropylacrylamide gel dosimeter doped iodinated contrast agents

    NASA Astrophysics Data System (ADS)

    Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Hsieh, B. T.

    2013-06-01

    Low toxicity of N-isopropylacrylamide (NIPAM) dosimeter was doped with clinical iodinated contrast medium agents(Iobitridol (Xenetix® 350) and organically bound iodine (Conray® 60) as radiation sensitizers; The suitable gel dosimeter preparation formula in this research was 5 w/w% gelatin, 5 w/w% N-isopropylacrylamide, 3 w/w% N,N-methylene-bis-acrylamide, and 5 mM Tetrakis phosphonium chloride. The spiral CT was irradiator, and 120 kVp was the operating tube voltage. The maximum radiation dose was 0.6 Gy, and optical CT was the gel measurement device used. The results showed SERs with the addition of radiosensitizers were 10.70 (Xenetix® 350) and 9.67 (Conray® 60), respectively. Thus, the polymerized gel dosimeter could be used in the efficacy evaluation of low-energy and low-radiation dose.

  6. Improving the Success Rate of Delivering Annual Occupational Dosimetry Reports to Persons Issued Temporary External Dosimeters

    SciTech Connect

    Mallett, Michael Wesley

    2014-09-09

    Workers who are not routinely monitored for occupational radiation exposure at LANL may be issued temporary dosimeters in the field. Per 10CFR835 and DOE O 231.1A, the Laboratory's radiation protection program is responsible for reporting these results to the worker at the end of the year. To do so, the identity of the worker and their mailing address must be recorded by the delegated person at the time the dosimeter is issued. Historically, this data has not been consistently captured. A new online application was developed to record the issue of temporary dosimeters. The process flow of the application was structured such that: 1) the worker must be uniquely identified in the Lab's HR database, and 2) the mailing address of record is verified live time via a commercial web service, for the transaction to be completed. A COPQ savings (Type B1) of $96K/year is demonstrated for the new application.

  7. Real-time monitoring and diagnosis of scintillation dosimeters using an ultraviolet light emitting diode

    NASA Astrophysics Data System (ADS)

    Yin, Y.; Lambert, J.; McKenzie, D. R.; Suchowerska, N.

    2008-05-01

    Plastic scintillator fibre optic dosimeters (FODs) have advantages for both brachytherapy and external beam radiotherapy applications. Convenient real-time monitoring and diagnosis of such dosimeters are desirable because of changes in the optical circuit that may arise in use. In this paper, we propose and demonstrate a real-time method using ultraviolet light emitting diodes (LED) to stimulate the scintillator and to diagnose failures of FODs. Key aspects of the LED FOD dosimetry design are investigated, enabling the design of a stable and accurate real-time monitoring dosimetry system. We demonstrate experimentally that the real-time monitoring FOD system is convenient to be used to monitor FOD dosimeters and to diagnose their failures resulted from different mechanisms.

  8. Radio-physical properties of micelle leucodye 3D integrating gel dosimeters

    NASA Astrophysics Data System (ADS)

    Vandecasteele, J.; Ghysel, S.; Baete, S. H.; De Deene, Y.

    2011-02-01

    Recently, novel radiochromic leucodye micelle hydrogel dosimeters were introduced in the literature. In these studies, gel measured electron depth dose profiles were compared with ion chamber depth dose data, from which it was concluded that leucocrystal violet-type dosimeters were independent of dose rate. Similar conclusions were drawn for leucomalachite green-type dosimeters, only after pre-irradiating the samples to a homogeneous radiation dose. However, in our extensive study of the radio-physical properties of leucocrystal violet- and leucomalachite green-type dosimeters, a significant dose rate dependence was found. For a dose rate variation between 50 and 400 cGy\\,min^{-1}, a maximum difference of 75% was found in optical dose sensitivity for the leucomalachite green-type dosimeter. Furthermore, the measured optical dose sensitivity of the leucomalachite green-type dosimeter was four times lower than the value previously reported in the literature. For the leucocrystal violet-type dosimeter, a maximum difference in optical dose sensitivity of 55% was found between 50 and 400 cGy\\,min^{-1}. A modified composition of the leucomalachite green-type dosimeter is proposed. This dosimeter is composed of gelatin, sodium dodecyl sulfate, chloroform, trichloroacetic acid and leucomalachite green. The optical dose sensitivity amounted to 4.375 \\times 10^{-5} \\,cm^{-1}\\; cGy^{-1} (dose rate 400 cGy\\,min^{-1}). No energy dependence for photon energies between 6 and 18 MV was found. No temperature dependence during readout was found notwithstanding a temperature dependence during irradiation of 1.90 cGy °C-1 increase on a total dose of 100 cGy. The novel gel dosimeter formulation exhibits an improved spatial stability (2.45 \\times 10^{-7} \\,cm^{2}\\; s^{-1} (= 0.088 mm^2 \\; h^{-1})) and good water/soft tissue equivalence. Nevertheless, the novel formulation was also found to have a significant, albeit reduced, dose rate dependence, as a maximum difference of 33

  9. Response of aqueous dichromate and nanoclay dichromate gel dosimeters to carbon ion irradiation

    NASA Astrophysics Data System (ADS)

    Maeyama, T.; Fukunishi, N.; Ishikawa, K. L.; Fukasaku, K.; Furuta, T.; Takagi, S.; Noda, S.; Himeno, R.; Fukuda, S.

    2013-06-01

    We have recently reported the significant reduction of radiation product diffusion by the incorporation of clay nanoparticles into dichromate gel (DCG) dosimeters. In this work, we investigate the influence of the nanoclay addition and gelation on the MRI R1 (1/T1) image response of the dichromate dosimeter to the therapeutic carbon ion beam (12C6+ 290 MeV/u). The MRI R1 distribution in the aqueous dichromate solution well reproduces physical dose-depth distribution with a high linear-energy-transfer (LET) efficiency. The nanoclay DCG dosimeters, on the other hand, exhibit composition-dependent LET efficiency degradation, while a sharp Bragg peak can still be detected. These results indicate that the nanocomposite gel addition may induce change in the radiation-induced reaction mechanism.

  10. Feasibility of PET/CT 3-D dosimetry for proton-activated PRESAGE® dosimeters

    NASA Astrophysics Data System (ADS)

    Carroll, M.; Ibbott, G.; Adamovics, J.

    2015-01-01

    A feasibility study is considered using PRESAGE® dosimeters as a direct dosimetry comparison tool to correlate proton activation to dose in a clinical beam. Proton activation measured by PET/CT has been studied as a future tool method for in vivo dosimetry. PRESAGE® is a 3D offline dosimeter that has a material composition giving it a longer activation decay time than similar dosimeters allowing easier measurements. In this study, the PRESAGE® positron emissions were measured by PET and directly compared to dose measurements made by optical-CT to make spatial comparisons of dose and proton activation. Profiles along the central axis of the beam found a shift in the distal-80% resulting in the proton activation profile being 1 cm shallower than the dose profile. Cross beam profiles demonstrated little discrepancy between long (3 hour) and short (30 minute) PET scan times.

  11. Thermal neutron response of the Li 2B 4O 7:Cu TL dosimeter

    NASA Astrophysics Data System (ADS)

    Gauld, I. C.; Harvey, J. W.; Kennett, T. J.; Prestwich, W. V.

    1986-10-01

    A measurement of the thermal neutron response of the Li 2B 4O 7:Cu TLD has been conducted. The results obtained using the Panasonic UD-806 dosimeter and UD-854A holder yield a free-in-air response of 3.3±0.1 R 60Co equivalent per mSv of thermal neutrons. A thermal neutron response of over 7 R 60Co equivalent per mSv was observed when the dosimeter was irradiated on water phantoms. The high sensitivity may result in a substantial overestimate of the gamma dose equivalent if the TLD is used in a mixed neutron and gamma environment of unknown ratio. Measurements of the Li 2B 4O 7:Cu glow curve, TL saturation curve and the thermal neutron response dependence of the dosimeter filtration thickness are also presented.

  12. Optical properties of a long dynamic range chemical UV dosimeter based on solvent cast polyvinyl chloride (PVC).

    PubMed

    Amar, Abdurazaq; Parisi, Alfio V

    2013-11-01

    The dosimetric properties of the recently introduced UV dosimeter based on 16 μm PVC film have been fully characterised. Drying the thin film in air at 50 °C for at least 28 days was found to be necessary to minimise the temperature effects on the dosimeter response. This research has found that the dosimeter response, previously reported to be mainly to UVB, has no significant dependence on either exposure temperature or dose rate. The dosimeter has negligible dark reaction and responds to the UV radiation with high reproducibility. The dosimeter angular response was found to have a similar pattern as the cosine function but deviates considerably at angles larger than 70°. Dose response curves exhibit monotonically increasing shape and the dosimeter can measure more than 900 SED. This is about 3 weeks of continuous exposure during summer at subtropical sites. Exposures measured by the PVC dosimeter for some anatomical sites exposed to solar radiation for twelve consecutive days were comparable with those concurrently measured by a series of PPO dosimeters and were in line with earlier results reported in similar studies.

  13. [Orofacial injuries in skateboard accidents].

    PubMed

    Frohberg, U; Bonsmann, M

    1992-04-01

    In a clinical study, 25 accidents involving injuries by a fall with a skateboard were investigated and classified in respect of epidemiology, accident mechanism and injury patterns in the facial region. Accident victims are predominantly boys between 7 and 9 years of age. A multiple trauma involving the teeth and the dental system in general and the soft parts of the face is defined as a characteristic orofacial injury pattern in skateboard accidents. The high proportion of damage to the front teeth poses problems of functional and aesthetic rehabilitation necessitating long-term treatment courses in children and adolescents. Effective prevention of facial injuries may be possible by evolving better facial protection systems and by creating areas of playgrounds where skateboarders can practise safely.

  14. Aircraft accidents : method of analysis

    NASA Technical Reports Server (NTRS)

    1929-01-01

    This report on a method of analysis of aircraft accidents has been prepared by a special committee on the nomenclature, subdivision, and classification of aircraft accidents organized by the National Advisory Committee for Aeronautics in response to a request dated February 18, 1928, from the Air Coordination Committee consisting of the Assistant Secretaries for Aeronautics in the Departments of War, Navy, and Commerce. The work was undertaken in recognition of the difficulty of drawing correct conclusions from efforts to analyze and compare reports of aircraft accidents prepared by different organizations using different classifications and definitions. The air coordination committee's request was made "in order that practices used may henceforth conform to a standard and be universally comparable." the purpose of the special committee therefore was to prepare a basis for the classification and comparison of aircraft accidents, both civil and military. (author)

  15. Method for correcting for isotope burn-in effects in fission neutron dosimeters

    DOEpatents

    Gold, Raymond; McElroy, William N.

    1988-01-01

    A method is described for correcting for effect of isotope burn-in in fission neutron dosimeters. Two quantities are measured in order to quantify the "burn-in" contribution, namely P.sub.Z',A', the amount of (Z', A') isotope that is burned-in, and F.sub.Z', A', the fissions per unit volume produced in the (Z', A') isotope. To measure P.sub.Z', A', two solid state track recorder fission deposits are prepared from the very same material that comprises the fission neutron dosimeter, and the mass and mass density are measured. One of these deposits is exposed along with the fission neutron dosimeter, whereas the second deposit is subsequently used for observation of background. P.sub.Z', A' is then determined by conducting a second irradiation, wherein both the irradiated and unirradiated fission deposits are used in solid state track recorder dosimeters for observation of the absolute number of fissions per unit volume. The difference between the latter determines P.sub.Z', A' since the thermal neutron cross section is known. F.sub.Z', A' is obtained by using a fission neutron dosimeter for this specific isotope, which is exposed along with the original threshold fission neutron dosimeter to experience the same neutron flux-time history at the same location. In order to determine the fissions per unit volume produced in the isotope (Z', A') as it ingrows during the irradiation, B.sub.Z', A', from these observations, the neutron field must generally be either time independent or a separable function of time t and neutron energy E.

  16. The Neutron Energy Response of the Panasonic Model 809 Personnel Dosimeter

    SciTech Connect

    Frederick Cummings

    2010-04-01

    In 2010, the U.S. Department of Energy will adopt a new set of radiation weighting factors and quality factors to be consistent with values recommended by the International Commission on Radiological Protection. The change will affect the magnitude of occupational exposure assigned to radiation workers exposed to neutron radiation. Understanding the energy response of the dosimeter and the effect of the new quantities is critical to accurately ensuring that occupational exposure remains below the established regulatory limits. Therefore, the factors used to interpret dosimeter readings must be re-evaluated for each irradiation field over the range of neutron energies in which the dosimeter is used. This paper describes one method of determining the neutron response of the dosimeter. A Monte Carlo approach was used to model the energy response of the Panasonic Model 809 dosimeter over the range of energies from 1.0 x 10^-8 to 20 MeV. The response, normalized to the response at 2.1 MeV, ranged from approximately 0.5 at 20 MeV to approximately 26 at 1 eV. The response was then divided at each energy by the appropriate dose conversion coefficient to determine the dose response of the dosimeter. The dose responses, normalized to the response at 2.1 MeV, ranged from approximately 0.4 at 20 MeV to 765 at 1 eV. Dose conversion factors were determined for various reference neutron spectra and plotted on the dose response curve. Good agreement was observed except for the case of D2Omoderated 252Cf.

  17. The energy dependence of lithium formate and alanine EPR dosimeters for medium energy x rays

    SciTech Connect

    Waldeland, Einar; Hole, Eli Olaug; Sagstuen, Einar; Malinen, Eirik

    2010-07-15

    Purpose: To perform a systematic investigation of the energy dependence of alanine and lilthium formate EPR dosimeters for medium energy x rays. Methods: Lithium formate and alanine EPR dosimeters were exposed to eight different x-ray beam qualities, with nominal potentials ranging from 50 to 200 kV. Following ionometry based on standards of absorbed dose to water, the dosimeters were given two different doses of approximately 3 and 6 Gy for each radiation quality, with three dosimeters for each dose. A reference series was also irradiated to three different dose levels at a {sup 60}Co unit. The dose to water energy response, that is, the dosimeter reading per absorbed dose to water relative to that for {sup 60}Co {gamma}-rays, was estimated for each beam quality. In addition, the energy response was calculated by Monte Carlo simulations and compared to the experimental energy response. Results: The experimental energy response estimates ranged from 0.89 to 0.94 and from 0.68 to 0.90 for lithium formate and alanine, respectively. The uncertainties in the experimental energy response estimates were typically 3%. The relative effectiveness, that is, the ratio of the experimental energy response to that following Monte Carlo simulations was, on average, 0.96 and 0.94 for lithium formate and alanine, respectively. Conclusions: This work shows that lithium formate dosimeters are less dependent on x-ray energy than alanine. Furthermore, as the relative effectiveness for both lithium formate and alanine were systematically less than unity, the yield of radiation-induced radicals is decreased following x-irradiation compared to irradiation with {sup 60}Co {gamma}-rays.

  18. SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

    SciTech Connect

    Gawad, M Abdel; Elgohary, M; Hassaan, M; Emam, M; Desouky, O; Eldib, A; Ma, C

    2015-06-15

    Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric

  19. Spine Immobilizer for Accident Victims

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C.; Lampson, K.

    1983-01-01

    Proposed conformal bladder filled with tiny spheres called "microballoons," enables spine of accident victim to be rapidly immobilized and restrained and permit victim to be safely removed from accident scene in extremely short time after help arrives. Microballoons expand to form rigid mass when pressure within bladder is less than ambient. Bladder strapped to victim is also strapped to rescue chair. Void between bladder and chair is filled with cloth wedges.

  20. Synthetic single crystal diamond dosimeters for Intensity Modulated Radiation Therapy applications

    NASA Astrophysics Data System (ADS)

    Almaviva, S.; Ciancaglioni, I.; Consorti, R.; De Notaristefani, F.; Manfredotti, C.; Marinelli, Marco; Milani, E.; Petrucci, A.; Prestopino, G.; Verona, C.; Verona-Rinati, G.

    2009-09-01

    A synthetic single crystal diamond Schottky diode, in a p-type/intrinsic/metal structure, deposited by Chemical Vapour Deposition (CVD) and operating in photovoltaic regime, with no external bias voltage applied, was tested as a dosimeter for Intensity Modulated Radiation Therapy (IMRT) applications. The device response was compared with dose measurements from two commercial ionization chambers and a 2D diode array in an IMRT prostate cancer treatment plan. The obtained results indicate that CVD synthetic single crystal diamond-based dosimeters can successfully be used for highly conformed radiotherapy and IMRT dosimetry, due to their small size and high sensitivity per unit volume.

  1. Initial Characterization of a Gel Patch Dosimeter for In Vivo Dosimetry

    PubMed Central

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2016-01-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6%T normoxic polyacrylamide gel, was injected into 1-cm thick acrylic molds to create 1-cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose response of all three batches of gel was found to be linear within the range of 2–20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  2. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    PubMed

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-07-08

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in

  3. A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

    SciTech Connect

    Chen, C. D.; Porkolab, M.; King, J. A.; Beg, F. N.; Key, M. H.; Chen, H.; Mackinnon, A. J.; MacPhee, A. G.; Patel, P. K.; Akli, K. U.; Stephens, R. B.; Freeman, R. R.; Link, A.; Van Woerkom, L. D.

    2008-10-15

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

  4. A Bremsstrahlung Spectrometer using k-edge and Differential Filters with Image plate dosimeters

    SciTech Connect

    Chen, C; Mackinnon, A; Beg, F; Chen, H; Key, M; King, J A; Link, A; MacPhee, A; Patel, P; Porkolab, M; Stephens, R; VanWoerkom, L; Akli, K; Freeman, R

    2008-05-02

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with Image Plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code Integrated Tiger Series 3.0 and the dosimeters calibrated with radioactive sources. Electron distributions with slope temperatures in the MeV range are inferred from the Bremsstrahlung spectra.

  5. Experimental determination of the influence of oxygen on the PRESAGE® dosimeter.

    PubMed

    Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2016-01-21

    It is generally accepted that the PRESAGE(®) radiochromic dosimeter is not sensitive to oxygen, however, this claim has not been supported or verified experimentally. Therefore, the aim of this study was to experimentally determine the potential influence of oxygen on dose sensitivity of the PRESAGE(®) dosimeter and its reporting system. Batches of PRESAGE(®) and its radical initiator-leuco dye reporting system were prepared in aerobic and anaerobic conditions. The anaerobic batches were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. The overall results show that oxygen has some influence on the dosimetric characteristics of PRESAGE(®), although the radical initiator does appear to oxidize the leucomalachite green even in the presence of oxygen. Deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ~30% when compared to the non-deoxygenated system. A minor increase in sensitivity (~5%) was also achieved by deoxygenating the PRESAGE(®) precursor prior to casting. In addition, dissolved oxygen measurements revealed low levels of dissolved oxygen (0.40 ± 0.04 mg l(-1)) in the polyurethane precursor used to fabricate the PRESAGE(®) dosimeters, as compared to water (8.60 ± 0.03 mg l(-1)) and the reporting system alone (1.30 ± 0.10 mg l(-1)). The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE(®) system. However, deoxygenation of the dosimeter precursors prior to casting improves the dosimeters dose sensitivity by ~5%, which might be particularly useful for measuring low radiation doses. Nevertheless, we

  6. On the response of electronic personal dosimeters in constant potential and pulsed x- ray beams

    NASA Astrophysics Data System (ADS)

    Guimarães, M. C.; Silva, C. R. E.; Oliveira, P. M. C.; da Silva, T. A.

    2016-07-01

    Electronic personal dosimeters (EPDs) based on solid state detectors have widely been used but some deficiencies in their response in pulsed radiation beams have been reported. Nowadays, there is not an international standard for pulsed x-ray beams for calibration or type testing of dosimeters. Irradiation conditions for testing the response of EPDs in both the constant potential and pulsed x-ray beams were established in CDTN. Three different types of EPDs were tested in different conditions in similar ISO and IEC x-ray qualities. Results stressed the need of performing additional checks before using EPDs in constant potential or pulsed x-rays.

  7. Initial characterization of a gel patch dosimeter for in vivo dosimetry

    NASA Astrophysics Data System (ADS)

    Matrosic, C.; Culberson, W.; Rosen, B.; Madsen, E.; Frank, G.; Bednarz, B.

    2016-05-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose–responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose–response of all three batches of gel was found to be linear within the range of 2–20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in

  8. Neutron dosimetry at commercial nuclear plants. Final report of Subtask B: dosimeter response

    SciTech Connect

    Cummings, F.M.; Endres, G.W.R.; Brackenbush, L.W.

    1983-03-01

    As part of a larger program to evaluate personnel neutron dosimetry at commercial nuclear power plants, this study was designed to characterize neutron dosimeter responses inside the containment structure of commercial nuclear plants. In order to characterize those responses, dosimeters were irradiated inside containment at 2 pressurized water reactors and at pipe penetrations outside the biological shield at two boiling water reactors. The reactors were operating at full power during the irradiations. Measurements were also performed with electronic instruments, the tissue equivalent proportional counter (TEPC), and portable remmeters, SNOOPY, RASCAL and PNR-4.

  9. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    PubMed

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-01-01

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in

  10. Novel Multicompartment 3-Dimensional Radiochromic Radiation Dosimeters for Nanoparticle-Enhanced Radiation Therapy Dosimetry

    SciTech Connect

    Alqathami, Mamdooh; Blencowe, Anton; Yeo, Un Jin; Doran, Simon J.; Qiao, Greg; Geso, Moshi

    2012-11-15

    Purpose: Gold nanoparticles (AuNps), because of their high atomic number (Z), have been demonstrated to absorb low-energy X-rays preferentially, compared with tissue, and may be used to achieve localized radiation dose enhancement in tumors. The purpose of this study is to introduce the first example of a novel multicompartment radiochromic radiation dosimeter and to demonstrate its applicability for 3-dimensional (3D) dosimetry of nanoparticle-enhanced radiation therapy. Methods and Materials: A novel multicompartment phantom radiochromic dosimeter was developed. It was designed and formulated to mimic a tumor loaded with AuNps (50 nm in diameter) at a concentration of 0.5 mM, surrounded by normal tissues. The novel dosimeter is referred to as the Sensitivity Modulated Advanced Radiation Therapy (SMART) dosimeter. The dosimeters were irradiated with 100-kV and 6-MV X-ray energies. Dose enhancement produced from the interaction of X-rays with AuNps was calculated using spectrophotometric and cone-beam optical computed tomography scanning by quantitatively comparing the change in optical density and 3D datasets of the dosimetric measurements between the tissue-equivalent (TE) and TE/AuNps compartments. The interbatch and intrabatch variability and the postresponse stability of the dosimeters with AuNps were also assessed. Results: Radiation dose enhancement factors of 1.77 and 1.11 were obtained using 100-kV and 6-MV X-ray energies, respectively. The results of this study are in good agreement with previous observations; however, for the first time we provide direct experimental confirmation and 3D visualization of the radiosensitization effect of AuNps. The dosimeters with AuNps showed small (<3.5%) interbatch variability and negligible (<0.5%) intrabatch variability. Conclusions: The SMART dosimeter yields experimental insights concerning the spatial distributions and elevated dose in nanoparticle-enhanced radiation therapy, which cannot be performed using any of

  11. Initial characterization of a gel patch dosimeter for in vivo dosimetry

    NASA Astrophysics Data System (ADS)

    Matrosic, C.; Culberson, W.; Rosen, B.; Madsen, E.; Frank, G.; Bednarz, B.

    2016-05-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose-response of all three batches of gel was found to be linear within the range of 2-20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  12. Experimental determination of the influence of oxygen on the PRESAGE® dosimeter

    NASA Astrophysics Data System (ADS)

    Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2016-01-01

    It is generally accepted that the PRESAGE® radiochromic dosimeter is not sensitive to oxygen, however, this claim has not been supported or verified experimentally. Therefore, the aim of this study was to experimentally determine the potential influence of oxygen on dose sensitivity of the PRESAGE® dosimeter and its reporting system. Batches of PRESAGE® and its radical initiator-leuco dye reporting system were prepared in aerobic and anaerobic conditions. The anaerobic batches were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. The overall results show that oxygen has some influence on the dosimetric characteristics of PRESAGE®, although the radical initiator does appear to oxidize the leucomalachite green even in the presence of oxygen. Deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ~30% when compared to the non-deoxygenated system. A minor increase in sensitivity (~5%) was also achieved by deoxygenating the PRESAGE® precursor prior to casting. In addition, dissolved oxygen measurements revealed low levels of dissolved oxygen (0.40  ±  0.04 mg l-1) in the polyurethane precursor used to fabricate the PRESAGE® dosimeters, as compared to water (8.60  ±  0.03 mg l-1) and the reporting system alone (1.30  ±  0.10 mg l-1). The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE® system. However, deoxygenation of the dosimeter precursors prior to casting improves the dosimeters dose sensitivity by ~5%, which might be particularly useful for measuring low radiation doses

  13. Projecting future climate change: Implications of carbon cycle model intercomparisons

    NASA Astrophysics Data System (ADS)

    Kheshgi, Haroon S.; Jain, Atul K.

    2003-06-01

    The range of responses of alternate detailed models for the ocean and biosphere components of the global carbon cycle, cataloged in model intercomparison studies, are simulated by a reduced form Earth system model employing a range of model parameters. The reduced form model, parameterized in this way, allows the integration of these components of the carbon cycle with an energy balance climate model with a prescribed range of climate sensitivity. We use this model to construct ranges of: (1) past carbon budgets given past CO2 concentrations, fossil carbon emissions, and temperature records, (2) future CO2 concentrations and temperature for given emission scenarios, and (3) CO2 emissions and temperature for given trajectories of future CO2 concentrations leading to constant levels within the next several centuries. Carbon cycle is an additional contributor to uncertainty in climate projections that is calculated to expand the range of projected global temperature beyond that reported in the 2001 Intergovernmental Panel on Climate Change assessment.

  14. An intercomparison exercise on technetium-99 in seaweed

    SciTech Connect

    Bates, T.H. )

    1988-01-01

    This paper reports the results of an intercomparison exercise carried out on the determination of {sup 99}Tc in Fucus vesiculosus taken from the coastline adjacent to Sellafield. This species of seaweed has a very high affinity for the radionuclide (e.g., two orders of magnitude higher than has the edible prophyra species); it presents, therefore, a potential source for a biological reference material with the highest possible specific activity. Details of the preparation and homogeneity testing before distribution of samples for analysis are described and summaries of analytical procedures used by each participant are provided. The exercise was arranged by the UK Analysts' Informal Working Group and participants comprised laboratories considered to be expert in the analysis and others who were using the opportunity to demonstrate their capability to perform this type of determination. 17 refs., 4 tabs.

  15. Hadronic shower code inter-comparison and verification

    SciTech Connect

    Mokhov, N.V.; Striganov, S.I.; /Fermilab

    2007-01-01

    To evaluate the quality of general purpose particle interaction and transport codes widely used in the high-energy physics community, express benchmarking is conducted. Seven tasks, important for high-energy physics applications, are chosen. For this first shot, they are limited to particle production on thin and thick targets and energy deposition in targets and calorimetric setups. Five code groups were asked to perform calculations in the identical conditions and provide results to the authors of this report. Summary of the code inter-comparison and verification against available experimental data is presented in this paper. Agreement is quite reasonable in many cases, but quite serious problems were revealed in the others.

  16. Nuclear fuel cycle facility accident analysis handbook

    SciTech Connect

    Ayer, J E; Clark, A T; Loysen, P; Ballinger, M Y; Mishima, J; Owczarski, P C; Gregory, W S; Nichols, B D

    1988-05-01

    The Accident Analysis Handbook (AAH) covers four generic facilities: fuel manufacturing, fuel reprocessing, waste storage/solidification, and spent fuel storage; and six accident types: fire, explosion, tornado, criticality, spill, and equipment failure. These are the accident types considered to make major contributions to the radiological risk from accidents in nuclear fuel cycle facility operations. The AAH will enable the user to calculate source term releases from accident scenarios manually or by computer. A major feature of the AAH is development of accident sample problems to provide input to source term analysis methods and transport computer codes. Sample problems and illustrative examples for different accident types are included in the AAH.

  17. Intercomparison exercise on external gamma dose rate under field conditions at the laboratory of natural radiation (Saelices el Chico, Spain).

    PubMed

    Gutierrez-Villanueva, J L; Sainz-Fernández, C; Fuente-Merino, I; Sáez-Vergara, J C; Correa-Garcés, E; Quindos-Poncela, L S

    2013-08-01

    The last nuclear accident in Fukushima nuclear power plant has increased the necessity for measuring radiation in the environment. Therefore, radiation monitors providing results traceable throughout the country become essential and it is very important to test them under the same environmental conditions. The first intercomparison of natural radioactivity under field conditions was held in Saelices el Chico (Salamanca, Spain) in May 2011, including an exercise on environmental dose rate. This article presents the results achieved by 19 instruments belonging to 12 institutions from 7 different countries. The tested detectors are proportional counters, ionisation chambers, Geiger-Müller and scintillators measuring dose rate in three stations with reference values from 110 to 1800 nGy h(-1). All the results were given in terms of air kerma (nGy h(-1)) and the measurements show agreement within 25 % in all the sites. Evaluation criteria based on accuracy and statistical uncertainty were also carried out and 25 % of participants passed the test in all sites.

  18. ISMIP6: Ice Sheet Model Intercomparison Project for CMIP6

    NASA Astrophysics Data System (ADS)

    Nowicki, Sophie; Payne, Tony; Larour, Eric; Abe Ouchi, Ayako; Goelzer, Heiko; Gregory, Jonathan; Lipscomb, William; Seroussi, Helene; Shepherd, Andrew

    2015-04-01

    The sea level projections made by the glaciological community as part of the Intergovernmental Panel on Climate Change (IPCC) process have often been out of phase with the projections considered by the wider Coupled Model Intercomparison Project (CMIP) community. For instance in AR5, the ice2sea and SeaRISE (Sea-level Response to Ice Sheet Evolution) ice sheet projects predominantly worked with AR4 scenarios, while the CMIP5 community used new future scenarios. As the next phase of CMIP is being designed (CMIP6), an effort for ice sheet models to be better integrated in the CMIP6 initiative has been proposed to the CMIP panel. We present the framework for the new effort, ISMIP6, the Ice Sheet Model Intercomparison Project for CMIP6. The primary goal of ISMIP6 is to improve projections of sea level rise via improved projections of the evolution of the Greenland and Antarctic ice sheets under a changing climate, along with a quantification of associated uncertainties (including uncertainty in both climate forcing and ice-sheet response). This goal requires an evaluation of AOGCM climate over and surrounding the ice sheets; analysis of simulated ice-sheet response from standalone models forced "offline" with CMIP AOGCM outputs and, where possible, with coupled ice sheet-AOGCM models; and experiments with standalone ice sheet models targeted at exploring the uncertainty associated with ice sheets physics, dynamics and numerical implementation. A secondary goal is to investigate the role of feedbacks between ice sheets and climate in order to gain insight into the impact of increased mass loss from the ice sheets on regional and global sea level, and of the implied ocean freshening on the coupled ocean-atmosphere circulation. These goals map into both Cryosphere and Sea-Level Rise Grand Challenges relevant to Climate and Cryosphere (CliC) and the World Climate Research Program (WCRP).

  19. Low-Level Waste Drum Assay Intercomparison Study

    SciTech Connect

    Greutzmacher, K.; Kuzminski, J.; Myers, S. C.

    2003-02-26

    Nuclear waste assay is an integral element of programs such as safeguards, waste management, and waste disposal. The majority of nuclear waste is packaged in drums and analyzed by various nondestructive assay (NDA) techniques to identify and quantify the radioactive content. Due to various regulations and the public interest in nuclear issues, the analytical results are required to be of high quality and supported by a rigorous Quality Assurance (QA) program. A valuable QA tool is an intercomparison program in which a known sample is analyzed by a number of different facilities. While transuranic waste (TRU) certified NDA teams are evaluated through the Performance Demonstration Program (PDP), low-level waste (LLW) assay specialists have not been afforded a similar opportunity. NDA specialists from throughout the DOE complex were invited to participate in this voluntary drum assay intercomparison study that was organized and facilitated by the Solid Waste Operations and the Safeguards Science and Technology groups at the Los Alamos National Laboratory and by Eberline Services. Each participating NDA team performed six replicate blind measurements of two 55-gallon drums with relatively low-density matrices (a 19.1 kg shredded paper matrix and a 54.4 kg mixed metal, rubber, paper and plastic matrix). This paper presents the results from this study, with an emphasis on discussing the lessons learned as well as desirable follow up programs for the future. The results will discuss the accuracy and precision of the replicate measurements for each NDA team as well as any issues that arose during the effort.

  20. Accident Tolerant Fuel Analysis

    SciTech Connect

    Curtis Smith; Heather Chichester; Jesse Johns; Melissa Teague; Michael Tonks; Robert Youngblood

    2014-09-01

    Safety is central to the design, licensing, operation, and economics of Nuclear Power Plants (NPPs). Consequently, the ability to better characterize and quantify safety margin holds the key to improved decision making about light water reactor design, operation, and plant life extension. A systematic approach to characterization of safety margins and the subsequent margins management options represents a vital input to the licensee and regulatory analysis and decision making that will be involved. The purpose of the Risk Informed Safety Margin Characterization (RISMC) Pathway research and development (R&D) is to support plant decisions for risk-informed margins management by improving economics and reliability, and sustaining safety, of current NPPs. Goals of the RISMC Pathway are twofold: (1) Develop and demonstrate a risk-assessment method coupled to safety margin quantification that can be used by NPP decision makers as part of their margin recovery strategies. (2) Create an advanced “RISMC toolkit” that enables more accurate representation of NPP safety margin. In order to carry out the R&D needed for the Pathway, the Idaho National Laboratory is performing a series of case studies that will explore methods- and tools-development issues, in addition to being of current interest in their own right. One such study is a comparative analysis of safety margins of plants using different fuel cladding types: specifically, a comparison between current-technology Zircaloy cladding and a notional “accident-tolerant” (e.g., SiC-based) cladding. The present report begins the process of applying capabilities that are still under development to the problem of assessing new fuel designs. The approach and lessons learned from this case study will be included in future Technical Basis Guides produced by the RISMC Pathway. These guides will be the mechanism for developing the specifications for RISMC tools and for defining how plant decision makers should propose and

  1. [Accidents of fulguration].

    PubMed

    Virenque, C; Laguerre, J

    1976-01-01

    Fulguration, first electric accident in which the man was a victim, is to day better known. A clap of thunder is decomposed in two elements: lightning, and thunder. Lightning is caused by an electrical discharge, either within a cloud, or between two clouds, or, above all, between a cloud and the surface of the ground. Experimental equipments owned by the French Electricity Company and by the Atomic Energy Commission, have allowed to photograph lightnings and to measure certain physical characteristics (Intensity variable between 25 to 100 kA, voltage variable between 20 to 1 000 kV). The frequency of storms was learned: the isokeraunic level, in France, is about 20, meaning that thunder is heard twenty days during one year. Man may be stricken by thunder by direct hit, by sudden bursting, by earth current, or through various conductors. The electric charge which reached him may go to the earth directly by contact with the ground or may dissipate in the air through a bony promontory (elbow). The total number of victims, "wounded" or deceased, is not now known by statistics. Death comes by insulation breakdown of one of several anatomic cephalic formations: skull, meninx, brain. Many various lesions may happen in survivors: loss of consciousness, more or less long, sensorial or motion deficiencies. All these signs are momentary and generally reversible. Besides one may observe much more intense lesions on the skin: burns and, over all, characteristic aborescence (skin effect by high frequency current). The heart is protected, contrarily to what happens with industrial electrocution. The curative treatment is merely symptomatic : reanimation, surgery for burns or associated traumatic lesions. A prevention is researched to help the lonely man, in the country or in the mountains in the houses (lightning conductor, Faraday cage), in vehicles (aircraft, cars, ships). The mysterious and unforseeable character of lightning still stays, leaving a door opened for numerous

  2. Accident tolerant fuel analysis

    SciTech Connect

    Smith, Curtis; Chichester, Heather; Johns, Jesse; Teague, Melissa; Tonks, Michael Idaho National Laboratory; Youngblood, Robert

    2014-09-01

    Safety is central to the design, licensing, operation, and economics of Nuclear Power Plants (NPPs). Consequently, the ability to better characterize and quantify safety margin holds the key to improved decision making about light water reactor design, operation, and plant life extension. A systematic approach to characterization of safety margins and the subsequent margins management options represents a vital input to the licensee and regulatory analysis and decision making that will be involved. The purpose of the Risk Informed Safety Margin Characterization (RISMC) Pathway research and development (R&D) is to support plant decisions for risk-informed margins management by improving economics and reliability, and sustaining safety, of current NPPs. Goals of the RISMC Pathway are twofold: (1) Develop and demonstrate a risk-assessment method coupled to safety margin quantification that can be used by NPP decision makers as part of their margin recovery strategies. (2) Create an advanced ''RISMC toolkit'' that enables more accurate representation of NPP safety margin. In order to carry out the R&D needed for the Pathway, the Idaho National Laboratory is performing a series of case studies that will explore methods- and tools-development issues, in addition to being of current interest in their own right. One such study is a comparative analysis of safety margins of plants using different fuel cladding types: specifically, a comparison between current-technology Zircaloy cladding and a notional ''accident-tolerant'' (e.g., SiC-based) cladding. The present report begins the process of applying capabilities that are still under development to the problem of assessing new fuel designs. The approach and lessons learned from this case study will be included in future Technical Basis Guides produced by the RISMC Pathway. These guides will be the mechanism for developing the specifications for RISMC tools and for defining how plant decision makers should propose and

  3. INTERCOMPARISON STUDY OF ATMOSPHERIC MERCURY MODELS: 1. COMPARISON OF MODELS WITH SHORT-TERM MEASUREMENTS

    EPA Science Inventory

    Five regional scale models with a horizontal domain covering the European continent and its surrounding seas, one hemispheric and one global scale model participated in an atmospheric mercury modelling intercomparison study. Model-predicted concentrations in ambient air were comp...

  4. Intercomparison of three microwave/infrared high resolution line-by-line radiative transfer codes

    NASA Astrophysics Data System (ADS)

    Schreier, F.; Garcia, S. Gimeno; Milz, M.; Kottayil, A.; Höpfner, M.; von Clarmann, T.; Stiller, G.

    2013-05-01

    An intercomparison of three line-by-line (lbl) codes developed independently for atmospheric sounding - ARTS, GARLIC, and KOPRA - has been performed for a thermal infrared nadir sounding application assuming a HIRS-like (High resolution Infrared Radiation Sounder) setup. Radiances for the HIRS infrared channels and a set of 42 atmospheric profiles from the "Garand dataset" have been computed. Results of this intercomparison and a discussion of reasons of the observed differences are presented.

  5. Results of the intercalibration study of laboratories involved in assessing the environmental consequences of the Chernobyl accident.

    PubMed

    Cooper, E L; Valkovic, V; Strachnov, V; Dekner, R; Danesi, P R

    1992-01-01

    Within the framework of the International Chernobyl Project, the IAEA's Seibersdorf Laboratories organized an intercalibration exercise among some of the laboratories which were involved in assessing the environmental contamination in the USSR due to the accident. The objective was to assess the reliability of the radioanalytical data for food and environmental samples, which were used to assess the doses. In the initial study reference materials from the stocks of the IAEA's Analytical Quality Control Services (AQCS) were re-labelled and submitted to 71 laboratories as blind samples. These natural matrix materials included samples of milk (containing 2 different levels of radioactivity), soil, air filters and clover. The concentrations of radionuclides in these samples were known from previous intercalibration exercises. The overall range in performance was broad, which is similar to what has been observed in previous international intercomparisons. The results obtained by gamma-ray spectrometry tended to be somewhat underestimated, on average. On the other hand, the laboratories showed an overall tendency to overestimate 90Sr and possibly 239Pu, which were analysed radiochemically. The intercalibration exercise is continuing with nine materials, including: soil, grass, hay and milk powder contaminated with fallout from the Chernobyl accident. These materials, which were prepared by laboratories in the USSR, are now being tested by AQCS prior to future intercomparison exercises. Work with these materials is expected to continue for several years.

  6. Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams

    SciTech Connect

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan

    2012-04-15

    Purpose: Optically stimulated luminescent detectors (OSLDs) have a number of advantages in radiation dosimetry making them excellent dosimeters for quality assurance and patient dose verification. Although the dosimeters have been investigated in several modalities, relatively little work has been done in examining the dosimeters for use in clinical proton beams. This study examined a number of characteristics of the response of the dosimeters in the spread-out Bragg peak (SOBP) region of clinical proton beams. Methods: Optically stimulated luminescence (OSL) dosimeters from Landauer, Inc., specifically the nanoDot dosimeter, were investigated. These dosimeters were placed in a special phantom with a recess to fit the dosimeters without an air gap. Beams with nominal energies of 160, 200, and 250 MeV were used in the passively-scattered proton beam at the MD Anderson Cancer Center Proton Therapy Center. Dosimetric properties including linearity, field size dependence, energy dependence, residual signal as a function of cumulative dose, and postirradiation fading were investigated by taking measurements at the center of SOBPs. Results: The dosimeters showed 1% supralinearity at 200 cGy and 5% supralinearity at 1000 cGy. No noticeable field size dependence of the detector was found for field sizes from 2 x 2 cm{sup 2} to 18 x 18 cm{sup 2}. Residual signal as a function of cumulative dose showed a small increase for measurements up to 1000 cGy. Readout signal depletion of the dosimeters after consecutive readings showed a slightly larger depletion in protons for doses up to 500 cGy but not by a clinically significant amount. Within the center of various SOBP widths and proton energies the variation in response was less than 2%. An average beam quality factor of 1.089 with experimental standard deviation of 0.007 was determined and applied to the data such that the results were within 1.2% of ion chamber data. Conclusions: The nanoDot OSL dosimeter characteristics were

  7. Airborne sulfur trace species intercomparison campaign: Sulfur dioxide, dimethylsulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Hoell, James M., Jr.; Davis, Douglas D.

    1991-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of sulfur trace gases are presented. The intercomparison was part of the NASA Global Tropospheric Experiment (GTE) and was conducted during the summer of 1989. The intercomparisons were conducted on the Wallops Electra aircraft during flights from Wallops Island, Virginia, and Natal, Brazil. Sulfur measurements intercompared included sulfur dioxide (SO2), dimethylsulfide (DMS), hydrogen sulfide (H2S), carbon disulfide (CS2), and carbonyl sulfide (OCS). Measurement techniques ranged from filter collection systems with post-flight analyses to mass spectrometer and gas chromatograph systems employing various methods for measuring and identifying the sulfur gases during flight. Sampling schedules for the techniques ranged from integrated collections over periods as long as 50 minutes to one- to three-minute samples every ten or fifteen minutes. Several of the techniques provided measurements of more than one sulfur gas. Instruments employing different detection principles were involved in each of the sulfur intercomparisons. Also included in the intercomparison measurement scenario were a host of supporting measurements (i.e., ozone, nitrogen oxides, carbon monoxide, total sulfur, aerosols, etc.) for purposes of: (1) interpreting results (i.e., correlation of any noted instrument disagreement with the chemical composition of the measurement environment); and (2) providing supporting chemical data to meet CITE-3 science objectives of studying ozone/sulfur photochemistry, diurnal cycles, etc. The results of the intercomparison study are briefly discussed.

  8. Intercomparisons for integrating the radon-thoron detector of NIRP, China with NIRS, Japan.

    PubMed

    Wu, Yunyun; Cui, Hongxing; Zhang, Qingzhao; Shang, Bing

    2015-04-01

    Intercomparisons play an important role in maintaining a reasonable and accurate standard of measurement and quality. Integrating the radon-thoron detector of the National Institute for Radiological Protection (NIRP), China has continuously been a subject of four rounds of international intercomparisons organised by the National Institute of Radiological Sciences (NIRS), Japan during 2007-12. The intercomparisons were held at NIRS. The exercises included different exposures for both radon and thoron. The results of the intercomparison for the detectors of NIRP for both radon and thoron exposures were in the range of ±20% from the reference value and were categorised as 'Category I' in the intercomparison carried out in 2011. The radon and thoron results of the LD-P detector in four rounds of intercomparison exercises were summarised, and uncertainties of all the radon and thoron results of NIRP were within the acceptable range of 30% in environment. Radon and thoron measurement results between NIRP and NIRS were basically in agreement.

  9. Evaluation of the neutron dosimeter used by Martin Marietta Energy Systems, Inc., ability to meet the requirements of the American National Standard for Personnel Neutron Dosimeters (neutron energies less than 20 MeV) ANSI N319-1976

    SciTech Connect

    Gunter, R.J.

    1994-07-01

    An evaluation of the neutron dosimeter used by the Centralized External Dosimetry System of Martin Marietta Energy Systems, Inc., was performed, and the dosimeter was shown to meet the requirements of the American National Standard for Personnel Neutron Dosimeters, ANSI N319-1976. This report details the requirements of the Standard, describes the tests performed, and evaluates the results of testing. To demonstrate compliance with the Standard, dosimeters were irradiated with a {sup 252}Cf source while mounted on a standard phantom. Dose was measured using the routine methodology employed by the Centralized External Dosimetry System for neutron dosimetry. The ability to accurately measure neutron dose was compared to specific performance criteria from the Standard. This includes testing the lower limit of detection, upper limit of detection, precision of results, and the capability to detect neutrons in a high gamma dose environment. In addition to neutron exposure, the dosimeters were required to be exposed to environmental factors including temperature extremes, high humidity, exposure to room light, and a drop to a hard surface. Only after exposure to these conditions were the dosimeters read, with results compared to the requirements of the Standard. Normal use factors of routine neutron dosimetry influencing the accuracy, sensitivity, or precision of the dosimetry system were also evaluated to measure their impact on dosimeter response.

  10. Characteristics of polyacrylamide gel with THPC and Turnbull Blue gel dosimeters evaluated using optical tomography

    NASA Astrophysics Data System (ADS)

    Pilařová (Vávrů), Kateřina; Kozubíková, Petra; Šolc, Jaroslav; Spěváček, Václav

    2014-11-01

    The purpose of this study was to compare characteristics of radiochromic gel - Turnbull Blue gel (TB gel) with polymer gel - polyacrylamide gel and tetrakis hydroxymethyl phosphonium chloride (PAGAT) using optical tomography. Both types of gels were examined in terms of dose sensitivity, dose response linearity and background value of spectrophotometric absorbance. The calibration curve was obtained for 60Co irradiation performed on Gammacell 220 at predefined gamma dose levels between 0 and 140 Gy for TBG and 0-15 Gy for PAGAT. To measure relative dose distributions from stereotactic irradiation, dosimeters were irradiated on Leksell Gamma Knife Perfexion. The cylindrical glass housings filled with gel were attached to the stereotactic frame. They were exposed with single shot and 16 mm collimator by 65 Gy to a 50% prescription isodose for TB gel and 4 Gy to a 50% prescription isodose for PAGAT. Evaluations of dosimeters were performed on an UV-vis Spectrophotometer Helios β and an optical cone beam homemade tomography scanner with a 16-bit astronomy CCD camera with a set of color filters. The advantages and potential disadvantages for both types of gel dosimeters were summarized. Dose distribution in central slice and measured profiles of 16 mm shot shows excellent correspondence with treatment planning system Leksell GammaPlan® for both PAGAT and Turnbull Blue gels. Gel dosimeters are suitable for steep dose gradient verification. An optical tomography evaluation method is successful. Dose response characteristics of TB gel and PAGAT gel are presented.

  11. Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 1999

    SciTech Connect

    Bivins, Steven R.; Stoetzel, Gregory A.

    2000-09-19

    In January 1993, PNNL established an area monitoring dosimeter program in accordance with Article 514 of the DOE Radiological Control Manual. This program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a)(1)-(4) and Article 511.1 of the DOE Standard Radiological Control, personnel dosimetry shall be provided to 1) radiological workers who are likely to receive at least 100 mrem annually and 2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-1998 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 123 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during calendar year 1999. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas.

  12. Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 1998

    SciTech Connect

    SR Bivins; GA Stoetzel

    1999-06-17

    In January 1993, Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the Department of Energy (DOE) Radiological Control Manual (RCM). The purpose of the program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a)(1)-(4) and Article 511.1 of the RCM, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-1997 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 97 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during calendar year 1998. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas.

  13. Dose algorithm for EXTRAD 4100S extremity dosimeter for use at Sandia National Laboratories.

    SciTech Connect

    Potter, Charles Augustus

    2011-05-01

    An updated algorithm for the EXTRAD 4100S extremity dosimeter has been derived. This algorithm optimizes the binning of dosimeter element ratios and uses a quadratic function to determine the response factors for low response ratios. This results in lower systematic bias across all test categories and eliminates the need for the 'red strap' algorithm that was used for high energy beta/gamma emitting radionuclides. The Radiation Protection Dosimetry Program (RPDP) at Sandia National Laboratories uses the Thermo Fisher EXTRAD 4100S extremity dosimeter, shown in Fig 1.1 to determine shallow dose to the extremities of potentially exposed individuals. This dosimeter consists of two LiF TLD elements or 'chipstrates', one of TLD-700 ({sup 7}Li) and one of TLD-100 (natural Li) separated by a tin filter. Following readout and background subtraction, the ratio of the responses of the two elements is determined defining the penetrability of the incident radiation. While this penetrability approximates the incident energy of the radiation, X-rays and beta particles exist in energy distributions that make determination of dose conversion factors less straightforward in their determination.

  14. Thermal neutron fluence measurement in a research reactor using thermoluminescence dosimeter TLD-600.

    PubMed

    Torkzadeh, F; Manouchehri, F

    2006-03-01

    A thermal neutron fluence in the range between 10(11) and 10(13) n cm(-2) in the reactor core of the Tehran research reactor has been measured using TLD-600 thermoluminescence dosimeters. After a thermal treatment of 1 h at 400 degrees C followed by 20 h cooling down to room temperature of pre-exposed dosimeters in the reactor, the accumulated TL light was measured after periods of storage of 24, 48 and 72 h. The influence of the irradiation-induced damage effect on the response of TLDs and their subsequent readings has been minimized in this manner. The induced TL light due to self-activity in the TLD-600 dosimeters, which is dependent on the neutron fluence, caused a conveniently measurable TL glow curve. The induced TL in the dosimeter due to the Q-value for the beta-decay of tritium Ebeta-max = 18.6 keV has been reproduced separately by a beta source to check the proportions of radionuclides in the chip. A short theoretical treatment is also presented.

  15. Area monitoring dosimeter program for the Pacific Northwest National Laboratory: Results for CY 1997

    SciTech Connect

    Bivins, S.R.; Stoetzel, G.A.

    1998-07-01

    In January 1993, Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the US Department of Energy (DOE) Radiological Control Manual (RCM). The purpose of the program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a) (1)--(3) and Article 511.1 of the RCM, personnel dosimetry shall be provided to (1) radiological workers who are likely to receive at least 100 mrem annually, and (2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years (CY) 1993--1996 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 93 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during CY 1997. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusions that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas.

  16. Feasibility of reading LiF thermoluminescent dosimeters by electron spin resonance.

    PubMed

    Breen, S L; Battista, J J

    1999-08-01

    Lithium fluoride is a commonly used solid state dosimeter. During irradiation, electrons and holes become trapped in crystal imperfections; thermoluminescence dosimetry measures their thermally induced recombination. Electron paramagnetic resonance (EPR) spectroscopy can be used to measure the resonant absorption of microwaves by the unpaired electrons trapped in LiF. In an effort to extend the use of LiF dosimeters to smaller sizes and to the harsh environments encountered in internal dosimetry, EPR was evaluated as an alternative technique to read the radiation dose delivered to TLD-100 dosimeters. TLD-100 rods were irradiated with a 60Co source to doses of 10 Gy to 100 Gy. A radiation-induced signal (with a g-value of 2.002) could be detected only at liquid nitrogen temperatures at doses above 20 Gy. The EPR spectrum of irradiated LiF contains three components, one of which correlates positively with dose. However, the low sensitivity of the technique, and difficulty in interpreting the EPR spectrum from polycrystalline dosimeters, preclude its use as a dosimetry technique.

  17. Neutron Unfolding Code System for Calculating Neutron Flux Spectra from Activation Data of Dosimeter Foils.

    1982-04-30

    Version 00 As a part of the measurement and analysis plan for the Dosimetry Experiment at the "JOYO" experimental fast reactor, neutron flux spectral analysis is performed using the NEUPAC (Neutron Unfolding Code Package) code system. NEUPAC calculates the neutron flux spectra and other integral quantities from the activation data of the dosimeter foils.

  18. Considerations in the application of the electronic dosimeter to dose of record

    SciTech Connect

    Swinth, K.L.

    1997-12-01

    This report describes considerations for application of the electronic dosimeter (ED) as a measurement device for the dose of record (primary dosimetry). EDs are widely used for secondary dosimetry and advances in their reliability and capabilities have resulted in interest in their use to meet the needs of both primary and secondary dosimetry. However, the ED is an active device and more complex than the thermoluminescent and film dosimeters now in use for primary dosimetry. The user must evaluate the ED in terms of reliability, serviceability and radiations detected its intended application(s). If an ED is selected for primary dosimetry, the user must establish methods both for controlling the performance of the ED to ensure long term reliability of the measurements and for their proper use as a primary dosimeter. Regulatory groups may also want to develop methods to ensure adequate performance of the ED for dose of record. The purpose of the report is to provide an overview of considerations in the use of the ED for primary dosimetry. Considerations include recognizing current limitations, type testing of EDs, testing by the user, approval performance testing, calibration, and procedures to integrate the dosimeter into the users program.

  19. A Prototype RF Dosimeter for Independent Measurement of the Average Specific Absorption Rate (SAR) During MRI

    PubMed Central

    Stralka, John P; Bottomley, Paul A

    2008-01-01

    Purpose To develop a scanner-independent dosimeter for measuring the average radio frequency (RF) power deposition and specific absorption rates (SAR) for human MRI exposure. Materials and Methods A prototype dosimeter has a transducer with orthogonal conducting loops surrounding a small signal-generating MRI sample. The loops contain resistors whose values are adjusted to load the scanner’s MRI coils equivalent to an average head or body during MRI. The scanner adjusts its power output to normal levels during setup, using the MRI sample. Following calibration, the total power and average SAR deposited in the transducer are measured from the root-mean-square (rms) power induced in the transducer during MRI. Results A 1.5 Tesla head transducer was adjusted to elicit the same load as the average of nine adult volunteers. Once adjusted, the transducer loads other head coils the same as the head does. The dosimeter is calibrated at up to 20 W total deposited power and 4.5 W/kg SAR in the average head, with about 5% accuracy. Conclusion This dosimeter provides a simple portable means of measuring the power deposited in a body-equivalent sample load, independent of the scanner. Further work will develop SAR dosimetry for the torso and for higher fields. PMID:17969145

  20. A Novel Twin-TLD Radiation Dosimeter for Astronauts during LEO Missions

    NASA Astrophysics Data System (ADS)

    Mukherjee, Bhaskar; Lambert, Jamil; Fuentes, Carolina; Sunil, C.; Tripathy, Sam; Sarkar, Pradip Kumar

    2012-07-01

    During low earth orbiting (LEO) missions space vehicles are continuously bombarded with energetic protons from the sun and in the events of solar flare (SFE), the proton flux sporadically increases by many orders of magnitudes. The solar protons interact with the containment wall of the vehicle producing high-energy neutrons with a broad energy distribution as well as gamma rays, which result in a high radiation exposure to astronauts. By implementing pairs of TLD-700 (7LiF:Ti, Mg) and TLD-500 (alpha: Al2O3-C) chips we have developed a personal dosimeter for an accurate assessment of biological dose of high-energy mixed radiation field. Dosimeters were irradiated with high-energy neutrons produced by bombarding a 25*25*35 cm3 polystyrene plate phantom with high-energy therapeutic protons at Westdeutsches Protonentherapiezentrum Essen (WPE). The radiation field was simulated using the FLUKA code and the dosimeters were calibrated in-situ with a tissue equivalent proportional counter (TEPC). The operation principle of the novel twin-TLD personal dosimeter for astronauts will be highlighted in our presentation.

  1. Clinical application of radiophotoluminescent glass dosimeter for dose verification of prostate HDR procedure

    SciTech Connect

    Hsu, Shih-Ming; Yeh, Chien-Yi; Yeh, Tien-Chi; Hong, Ji-Hong; Tipton, Annie Y. H.; Chen, Wei-Li; Sun, Shung-Shung; Huang, David Y. C.

    2008-12-15

    High dose rate brachytherapy (HDR-BT) is one of the many modalities for prostate cancer treatment. Due to the nature of HDR-BT, in vivo dosimetry is feasible and can be used to verify consistent dose delivery. In order to validate a dose verification system for HDR-BT prostate cancer treatment, a radiophotoluminescent glass dosimeter (RPLGD) was used and the measurements were compared with those from a thermoluminescent dosimeter. The RPLGD shows many advantages in HDR-BT dose measurement, such as repeatability, stability, and small effective size. These advantages make the RPLGD a superior option for use as a dosimeter in HDR-BT. The results described here show that the difference between the measured dose and the treatment planned dose is less than 5%. A Monte Carlo simulation for the dose was performed using Monte Carlo N -particle to investigate position error. This study concludes that the RPLGD is a promising and reliable dosimeter for HDR-BT in vivo dosimetry with clinically acceptable accuracy.

  2. Dose-response measurement in gel dosimeter using various imaging modalities

    NASA Astrophysics Data System (ADS)

    Fujibuchi, T.; Kawamura, H.; Yamanashi, K.; Hiroki, A.; Yamashita, S.; Taguchi, M.; Sato, Y.; Mimura, K.; Ushiba, H.; Okihara, T.

    2013-06-01

    Measurement methods that accurately measure radiation dose distribution in a three dimensional manner in order to allow comparisons of treatment plans are needed for quality assurance. One such measurement method involves the use of a polymer gel dosimeter to measure the dose distribution in three dimensions. During irradiation, a polymerization reaction makes new chemical bonds and induces changes of the chemical structure of the gel of the gel dosimeter. In the present study, dose-response measurement of an environment-friendly material used in the gel dosimeter was performed by imaging with computed tomography (CT) and R1, R2, and fluid-attenuated inversion-recovery (FLAIR) magnetic resonance imaging (MRI) under various imaging conditions. Dose-response characteristics in the gel dosimeter used in the experiment were observed at doses of 5-20 Gy administered by X-ray CT and MRI. Although the FLAIR signal was a relative value, the dose-response values with FLAIR were excellent compared to those with R1, R2, and CT. Determination of more appropriate imaging conditions could help expand the dose-response parameters of each measurement method.

  3. A metal-oxide-semiconductor radiation dosimeter with a thick and defect-rich oxide layer

    NASA Astrophysics Data System (ADS)

    Liu, Hongrui; Yang, Yuhao; Zhang, Jinwen

    2016-04-01

    Enhancing the density of defects in the oxide layer is the main factor in improving the sensitivity of a metal-oxide-semiconductor (MOS) radiation dosimeter. This paper reports a novel MOS dosimeter with a very thick and defect-rich oxide layer fabricated by MEMS technology. The category of defects in SiO2 and their possible effect on the radiation dose sensing was analyzed. Then, we proposed combining deep-reactive-ion etching, thermal oxidation and low pressure chemical vapor deposition to realize an oxide layer containing multiple and large interfaces which can increase defects significantly. The trench-and-beam structure of silicon was considered in detail. The fabrication process was developed for obtaining a thick and compact MEMS-made SiO2. Our devices were irradiated by γ-rays of 60Co at 2 Gy per minute for 2 h and a thermally stimulated current (TSC) method was used to determine the readout of the dosimeters. Results show that there is a peak current of about 450 nA, indicating a total TSC charge of 158 μC and sensitivity of 1.1 μC mm-3·Gy, which is 40 times the sensitivity of previous MOS dosimeters.

  4. Validation of dose measurements by scintillating fiber optic dosimeters for medical applications

    NASA Astrophysics Data System (ADS)

    Correia, A.; Pirraco, R.; Rosa, C. C.

    2013-11-01

    Organic scintillators have been promoted and widely used in scintillating fiber-optic dosimeters (SFOD) due to their tissue-equivalent characteristics, small sensitive volume combined with high spatial resolution, and emission of visible light proportional to the absorbed electron and gamma dose rate. In this paper we will present the validation of Monte Carlo simulations of dose measurements assisted by scintillating fiber optic dosimeters operating in the visible spectral range, in the context of the development of fiber optic dosimeters targeted to Brachytherapy. The Monte Carlo simulation results are compared to measurements performed with SFOD test probes, assembled with BCF-60 (Saint Gobain) samples of 1 mm diameter and 0.35 to 1.5 cm length, coupled to PMMA optical fiber. The optical signal resulting from scintillation and Cherenkov light is transmitted through an additional optical fiber link to a remote measuring device. For SFOD probes irradiation a dedicated PMMA phantom was used. The results were validated against measurements obtained with a properly calibrated pinpoint ionization chamber (PTW). The probes were positioned in a radial arrangement, with a radioactive source at its center point. The γ-rays source is a Nucletron Microselectron-V2 192Ir. The dose curves are obtained according to the different positions in the phantom with the SFOD dosimeters. The system is able to use a Fiber Optic Multiplexer (FOM) controlled with Labview software.

  5. Method and apparatus for passive optical dosimeter comprising caged dye molecules

    DOEpatents

    Sandison, David R.

    2001-07-03

    A new class of ultraviolet dosimeters is made possible by exposing caged dye molecules, which generate a dye molecule on exposure to ultraviolet radiation, to an exterior environment. Applications include sunburn monitors, characterizing the UV exposure history of UV-sensitive materials, especially including structural plastics, and use in disposable `one-use` optical equipment, especially medical devices.

  6. Feasibility of CBCT dosimetry for IMRT using a normoxic polymethacrylic-acid gel dosimeter

    NASA Astrophysics Data System (ADS)

    Bong, Ji Hye; Kwon, Soo-Il; Kim, Kum Bae; Kim, Mi Suk; Jung, Hai Jo; Ji, Young Hoon; Ko, In Ok; Park, Ji Ae; Kim, Kyeong Min

    2013-09-01

    The purpose of this study is to evaluate the availability of cone-beam computed tomography(CBCT) for gel dosimetry. The absorbed dose was analyzed by using intensity-modulated radiation therapy(IMRT) to irradiate several tumor shapes with a calculated dose and several tumor acquiring images with CBCT in order to verify the possibility of reading a dose on the polymer gel dosimeter by means of the CBCT image. The results were compared with those obtained using magnetic resonance imaging(MRI) and CT. The linear correlation coefficients at doses less than 10 Gy for the polymer gel dosimeter were 0.967, 0.933 and 0.985 for MRI, CT and CBCT, respectively. The dose profile was symmetric on the basis of the vertical axis in a circular shape, and the uniformity was 2.50% for the MRI and 8.73% for both the CT and the CBCT. In addition, the gradient in the MR image of the gel dosimeter irradiated in an H shape was 109.88 while the gradients of the CT and the CBCT were 71.95 and 14.62, respectively. Based on better image quality, the present study showed that CBCT dosimetry for IMRT could be restrictively performed using a normoxic polymethacrylic-acid gel dosimeter.

  7. Implementation of the Panasonic TLD (Thermoluminescent Dosimeter) system for personnel monitoring at the Nevada Test Site

    SciTech Connect

    DeMarre, M.; Teasdale, C.L.; Sygitowicz, L.S.

    1988-01-01

    In January 1987, the dosimetry system at the Nevada Test Site changed from a film badge dosimetry program to the Panasonic Thermoluminescent Dosimeter (TLD) system to monitor external radiation exposure to personnel working at the Nevada Test Site. In order to implement the Panasonic TLD system, a combination dosimeter and security credential badge holder had to be developed, a computer processing system developed, a dose processing algorithm developed and enough Panasonic UD802AS2 TLDs purchased to support a large quarterly exchange. Problems that had to be resolved during the first year of operation were: processing approximately 15,000 dosimeters per quarter; multiple exchange of the same dosimeter in the same quarter due to incoming visitors and vendors; late returns due to the unique user community at the Nevada Test Site; TLD damage experience and unusual TLD anomalies. The experience from the original planning stages for conversion to the TLD system to the reality of the implementation of this system will be discussed.

  8. Measuring Day-Night Noise Levels (DNL) using the metrosonics db-310 sound level analyzer (Dosimeter)

    NASA Astrophysics Data System (ADS)

    Ali, Ali Y.

    1989-09-01

    The Metrosonics db-310 Dosimeter does not provide automatic calculation of DNLs for environmental noise surveys. Previous environmental noise surveys using the db-310 Dosimeter required DNL values to be calculated manually from the paper printout of sound levels. Manual calculations proved to be both laborious and monotonous; worse, one missed key stroke would require a restart of this whole calculation. In addition, the quality of the printouts are very poor if reproduction is required. The manual method of DNL calculating made long term environmental noise monitoring tedious and labor intensive with many opportunities for error. This report presents a program listing, setup requirements, procedures and operating instructions for DNL calculations using the Metrosonics db-310 Noise Dosimeter, a Z-248 or Z-184 Microcomputer, ENABLE software, and a BASIC program. Procedures and operating instructions describe: (1) programming the Metrosonics db-310 Dosimeter parameters for environmental noise measurements, (2) down loading its data to a Zenith Z-248 or Z-184 Computer using ENABLE, and (3) running a BASIC program which calculates the DNL and provides a hard copy of the results.

  9. Identification of severe accident uncertainties

    SciTech Connect

    Rivard, J.B.; Behr, V.L.; Easterling, R.G.; Griesmeyer, J.M.; Haskin, F.E.; Hatch, S.W.; Kolaczkowski, A.M.; Lipinski, R.J.; Sherman, M.P.; Taig, A.R.

    1984-09-01

    Understanding of severe accidents in light-water reactors is currently beset with uncertainty. Because the uncertainties that are present limit the capability to analyze the progression and possible consequences of such accidents, they restrict the technical basis for regulatory actions by the US Nuclear Regulatory Commission (NRC). It is thus necessary to attempt to identify the sources and quantify the influence of these uncertainties. As a part of ongoing NRC severe-accident programs at Sandia National Laboratories, a working group was formed to pool relevant knowledge and experience in assessing the uncertainties attending present (1983) knowledge of severe accidents. This initial report of the Severe Accident Uncertainty Analysis (SAUNA) working group has as its main goal the identification of a consolidated list of uncertainties that affect in-plant processes and systems. Many uncertainties have been identified. A set of key uncertainties summarizes many of the identified uncertainties. Quantification of the influence of these uncertainties, a necessary second step, is not attempted in the present report, although attempts are made qualitatively to demonstrate the relevance of the identified uncertainties.

  10. Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

    SciTech Connect

    Manjappa, Rakesh; Makki S, Sharath; Kanhirodan, Rajan; Kumar, Rajesh

    2015-02-15

    Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm

  11. Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters

    SciTech Connect

    Lye, Jessica Dunn, Leon; Kenny, John; Alves, Andrew; Lehmann, Joerg; Williams, Ivan; Kron, Tomas; Oliver, Chris; Butler, Duncan; Johnston, Peter; Franich, Rick

    2014-03-15

    Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectors are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3

  12. Solid-state dosimeters: A new approach for mammography measurements

    SciTech Connect

    Brateman, Libby F.; Heintz, Philip H.

    2015-02-15

    Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-field digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the SStD and

  13. Characteristics of a novel polymer gel dosimeter formula for MRI scanning: Dosimetry, toxicity and temporal stability of response.

    PubMed

    Abtahi, S M

    2016-09-01

    The present study intended to investigate the composition of a new polymer gel dosimeter. The new composition would be more suitable for a wide range of applications in comparison to polyacrylamide gel dosimeter since its extremely toxic acrylamide has been replaced with less harmful monomer i.e. 2-Acrylamido-2-MethylPropane Sulfonic acid (AMPS). To this end, the PAGAT gel dosimeter formula was used as a basis to test the new formulation of polymer gel dosimeter with a different monomer (AMPS) instead of acrylamide by using the %6T and %50C to the formula. The new formulation was named PAMPSGAT (Poly AMPS, Gelatin and THPC) polymer gel dosimeter. Moreover, the MRI response (R2) of dosimeters was analyzed in terms of different dose range as well as post-irradiation time. The results indicated that the dose-response (R2) of AMPS/Bis had a linear trend over a wide dose range. Furthermore, the results showed an acceptable temporal stability for the new polymer gel dosimeter.

  14. Determining the applicability of the Landauer nanoDot as a general public dosimeter in a research imaging facility.

    PubMed

    Charlton, Michael A; Thoreson, Kelly F; Cerecero, Jennifer A

    2012-11-01

    The Research Imaging Institute (RII) building at the University of Texas Health Science Center at San Antonio (UTHSCSA) houses two cyclotron particle accelerators, positron emission tomography (PET) machines, and a fluoroscopic unit. As part of the radiation protection program (RPP) and meeting the standard for achieving ALARA (as low as reasonably achievable), it is essential to minimize the ionizing radiation exposure to the general public through the use of controlled areas and area dose monitoring. Currently, thirty-four whole body Luxel+ dosimeters, manufactured by Landauer, are being used in various locations within the RII to monitor dose to the general public. The intent of this research was to determine if the nanoDot, a single point dosimeter, can be used as a general public dosimeter in a diagnostic facility. This was tested by first verifying characteristics of the nanoDot dosimeter including dose linearity, dose rate dependence, angular dependence, and energy dependence. Then, the response of the nanoDot dosimeter to the Luxel+ dosimeter when placed in a continuous, low dose environment was investigated. Finally, the nanoDot was checked for appropriate response in an acute, high dose environment. Based on the results, the current recommendation is that the nanoDot should not replace the Luxel+ dosimeter without further work to determine the energy spectra in the RII building and without considering the limitation of the microStar reader, portable on-site OSL reader, at doses below 0.1 mGy (10 mrad). PMID:23026976

  15. Characteristics of a novel polymer gel dosimeter formula for MRI scanning: Dosimetry, toxicity and temporal stability of response.

    PubMed

    Abtahi, S M

    2016-09-01

    The present study intended to investigate the composition of a new polymer gel dosimeter. The new composition would be more suitable for a wide range of applications in comparison to polyacrylamide gel dosimeter since its extremely toxic acrylamide has been replaced with less harmful monomer i.e. 2-Acrylamido-2-MethylPropane Sulfonic acid (AMPS). To this end, the PAGAT gel dosimeter formula was used as a basis to test the new formulation of polymer gel dosimeter with a different monomer (AMPS) instead of acrylamide by using the %6T and %50C to the formula. The new formulation was named PAMPSGAT (Poly AMPS, Gelatin and THPC) polymer gel dosimeter. Moreover, the MRI response (R2) of dosimeters was analyzed in terms of different dose range as well as post-irradiation time. The results indicated that the dose-response (R2) of AMPS/Bis had a linear trend over a wide dose range. Furthermore, the results showed an acceptable temporal stability for the new polymer gel dosimeter. PMID:27542576

  16. Use of multi-element beta dosimeters for measuring dose rates in the TMI-2 containment building

    SciTech Connect

    Scherpelz, R I; Endres, G W.R.; Rathbun, L A

    1983-09-01

    The use of thermoluminescent dosimeters (TLDs) for beta dosimetry has traditionally involved inaccuracies due to the energy-dependent response of the TLDs. In order to correct for the beta energy spectrum, researchers at the Pacific Northwest Laboratory (PNL - operated by Battelle Memorial Institute) have developed a dosimeter using TLDs under a number of different thickness of aluminum shields. The PNL multi-element beta dosimeter has been used in four-element and seven-element configurations. Design considerations, analysis procedures, quality assurance, and error determinations for the dosimeters are described in this report. The methods of data analysis used for converting TLD response to dose are also described. These multi-element dosimeters have been used to measure beta and gamma doses resulting from radioactive contaminants in the Three Mile Island Unit 2 containment building. Over 100 dosimeters have been used in three sets of experiments at a number of locations in the building. This report documents the experiments and presents the doses evaluated by the dosimeters.

  17. Dose evaluation of an NIPAM polymer gel dosimeter using gamma index

    NASA Astrophysics Data System (ADS)

    Chang, Yuan-Jen; Lin, Jing-Quan; Hsieh, Bor-Tsung; Yao, Chun-Hsu; Chen, Chin-Hsing

    2014-11-01

    An N-isopropylacrylamide (NIPAM) polymer gel dosimeter has great potential in clinical applications. However, its three-dimensional dose distribution must be assessed. In this work, a quantitative evaluation of dose distributions was performed to evaluate the NIPAM polymer gel dosimeter using gamma analysis. A cylindrical acrylic phantom filled with NIPAM gel measuring 10 cm (diameter) by 10 cm (height) by 3 mm (thickness) was irradiated by a 4×4 cm2 square light field. The irradiated gel phantom was scanned using an optical computed tomography (optical CT) scanner (OCTOPUS™, MGS Research, Inc., Madison, CT, USA) at 1 mm resolution. The projection data were transferred to an image reconstruction program, which was written using MATLAB (The MathWorks, Natick, MA, USA). The program reconstructed the image of the optical density distribution using the algorithm of a filter back-projection. Three batches of replicated gel phantoms were independently measured. The average uncertainty of the measurements was less than 1%. The gel was found to have a high degree of spatial uniformity throughout the dosimeter and good temporal stability. A comparison of the line profiles of the treatment planning system and of the data measured by optical CT showed that the dose was overestimated in the penumbra region because of two factors. The first is light scattering due to changes in the refractive index at the edge of the irradiated field. The second is the edge enhancement caused by free radical diffusion. However, the effect of edge enhancement on the NIPAM gel dosimeter is not as significant as that on the BANG gel dosimeter. Moreover, the dose uncertainty is affected by the inaccuracy of the gel container positioning process. To reduce the uncertainty of 3D dose distribution, improvements in the gel container holder must be developed.

  18. Water-equivalent dosimeter array for small-field external beam radiotherapy

    SciTech Connect

    Archambault, Louis; Beddar, A. Sam; Gingras, Luc; Lacroix, Frederic; Roy, Rene; Beaulieu, Luc

    2007-05-15

    With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array allows precise, rapid dose evaluation of small photon fields. Starting with a dosimeter system constructed with a single scintillating fiber coupled to a clear optical fiber and read using a charge coupled device camera, we looked at the dosimeter's spatial resolution under small radiation fields and angular dependence. Afterward, we analyzed the camera's light collection to determine the maximum array size that could be built. Finally, we developed a prototype made of ten scintillating fiber detectors to study the behavior and precision of this system in simple dosimetric situations. The scintillation detector showed no measurable angular dependence. Comparison of the scintillation detector and a small-volume ion chamber showed agreement except for 1x1 and 0.5x5.0 cm{sup 2} fields where the output factor measured by the scintillator was higher. The actual field of view of the camera could accept more than 4000 scintillating fiber detectors simultaneously. Evaluation of the dose profile and depth dose curve using a prototype with ten scintillating fiber detectors showed precise, rapid dose evaluation even with placement of more than 75 optical fibers in the field to simulate what would happen in a larger array. We concluded that this scintillating fiber dosimeter array is a valuable tool for dose measurement in external beam radiotherapy. It possesses the qualities necessary to evaluate small and irregular fields with various incident angles such as those encountered in intensity-modulated radiotherapy, radiosurgery, and tomotherapy.

  19. Severe accident simulation at Olkiuoto

    SciTech Connect

    Tirkkonen, H.; Saarenpaeae, T.; Cliff Po, L.C.

    1995-09-01

    A personal computer-based simulator was developed for the Olkiluoto nuclear plant in Finland for training in severe accident management. The generic software PCTRAN was expanded to model the plant-specific features of the ABB Atom designed BWR including its containment over-pressure protection and filtered vent systems. Scenarios including core heat-up, hydrogen generation, core melt and vessel penetration were developed in this work. Radiation leakage paths and dose rate distribution are presented graphically for operator use in diagnosis and mitigation of accidents. Operating on an graphically for operator use in diagnosis and mitigation of accidents. Operating on an 486 DX2-66, PCTRAN-TVO achieves a speed about 15 times faster than real-time. A convenient and user-friendly graphic interface allows full interactive control. In this paper a review of the component models and verification runs are presented.

  20. The child accident repeater: a review.

    PubMed

    Jones, J G

    1980-04-01

    The child accident repeater is defined as one who has at least three accidents that come to medical attention within a year. The accident situation has features in common with those of the child who has a single accident through simple "bad luck", but other factors predispose him to repeated injury. In the child who has a susceptible personality, a tendency for accident repetition may be due to a breakdown in adjustment to a stressful environment. Prevention of repeat accidents should involve the usual measures considered appropriate for all children as well as an attempt to provide treatment of significant maladjustment and modification of a stressful environment.