Science.gov

Sample records for accident dosimeter intercomparison

  1. PNNL Results from 2009 Silene Criticality Accident Dosimeter Intercomparison Exercise

    SciTech Connect

    Hill, Robin L.; Conrady, Matthew M.

    2010-06-30

    This document reports the results of testing of the Hanford Personnel Nuclear Accident Dosimeter (PNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on October 13, 14, and 15, 2009.

  2. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    SciTech Connect

    Hill, Robin L.; Conrady, Matthew M.

    2011-10-28

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participating Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.

  3. Nuclear accident dosimetry intercomparison studies.

    PubMed

    Sims, C S

    1989-09-01

    Twenty-two nuclear accident dosimetry intercomparison studies utilizing the fast-pulse Health Physics Research Reactor at the Oak Ridge National Laboratory have been conducted since 1965. These studies have provided a total of 62 different organizations a forum for discussion of criticality accident dosimetry, an opportunity to test their neutron and gamma-ray dosimetry systems under a variety of simulated criticality accident conditions, and the experience of comparing results with reference dose values as well as with the measured results obtained by others making measurements under identical conditions. Sixty-nine nuclear accidents (27 with unmoderated neutron energy spectra and 42 with eight different shielded spectra) have been simulated in the studies. Neutron doses were in the 0.2-8.5 Gy range and gamma doses in the 0.1-2.0 Gy range. A total of 2,289 dose measurements (1,311 neutron, 978 gamma) were made during the intercomparisons. The primary methods of neutron dosimetry were activation foils, thermoluminescent dosimeters, and blood sodium activation. The main methods of gamma dose measurement were thermoluminescent dosimeters, radiophotoluminescent glass, and film. About 68% of the neutron measurements met the accuracy guidelines (+/- 25%) and about 52% of the gamma measurements met the accuracy criterion (+/- 20%) for accident dosimetry. PMID:2777549

  4. Characterization of a nuclear accident dosimeter

    SciTech Connect

    Burrows, R.A.

    1995-12-01

    The 23rd nuclear accident dosimetry intercomparison was held during the week of June 12--16, 1995 at Los Alamos National Laboratory. This report presents the results of this event, referred to as NAD 23, as related to the performance of Sandia National Laboratories (SNL) personal nuclear accident dosimeter (PNAD). Two separate critical assemblies, SHEBA and Godiva, were used to generate seven separate neutron spectra for use in dose comparisons. SNL`s PNAD measured absorbed doses that were within +16 to +26% of the reference doses. In addition, a preliminary investigation was undertaken to determine the feasibility of using the data obtained from an irradiated PNAD to correct for body orientation. This portion of the experiment was performed with a TRIGA reactor at the Nuclear Science Center at Texas A and M University.

  5. Nuclear accident dosimeter processing with attenuation filters

    SciTech Connect

    Gunter, R.J.

    1994-05-01

    An evaluation of the Martin Marietta Energy Systems, Inc., Personnel Nuclear Accident Dosimeters was undertaken to determine if they could meet DOE 5480.11 requirements for photon dose assessment. Dosimeters were irradiated with a {sup 137}Cs source to doses ranging from 0.5 to 10,000 rad and processed using transmission filters to prevent photomultiplier tube saturation. Dose equivalent responses were found to meet the requirements using dosimeter reader number 55. Use of reader number 11 revealed a problem with current procedures. While performing a normal calibration with transmission filters in place it was discovered that there was a high noise component in the calibration signal, resulting in a poor calibration. Dosimeters processed with reader number 11 using a 1% transmission filter determined element 3 response 30% below expectations. The low element 3 response resulted in a significantly lower dose calculation for affected dosimeters. Another factor affecting overall response was an excessive supralinearity correction applied to dosimeters exposed between 100 and 1,000 rad.

  6. Seventeenth nuclear accident dosimetry intercomparison study: August 11-15, 1980

    SciTech Connect

    Swaja, R.E.; Greene, R.T.

    1981-04-01

    The Seventeenth Nuclear Accident Dosimetry Intercomparison Study was conducted August 11-15, 1980, at the Oak Ridge National Laboratory. Nuclear criticality accidents with three different neutron and gamma ray energy spectra were simulated by operating the Health Physics Research Reactor in the pulse mode. Participants from 13 organizations exposed dosimeters set up as area monitors and mounted on phantoms for personnel monitoring. Analysis of experimental results reported by participants showed that less than 60% of the neutron dose measurements using foil activation, thermoluminescent, or sodium activation methods and less than 20% of the gamma dose measurements using thermoluminescent dosimeters met nuclear criticality accident dosimetry guidelines which suggest accuracies of +-25% for neutron dose and +-20% for gamma dose. This indicates that continued development and evaluation of criticality accident dosimetry systems for area and personnel monitoring are required to improve measurement accuracy so that existing standards can be met.

  7. Evaluation of LLNL's Nuclear Accident Dosimeters at the CALIBAN Reactor September 2010

    SciTech Connect

    Hickman, D P; Wysong, A R; Heinrichs, D P; Wong, C T; Merritt, M J; Topper, J D; Gressmann, F A; Madden, D J

    2011-06-21

    The Lawrence Livermore National Laboratory uses neutron activation elements in a Panasonic TLD holder as a personnel nuclear accident dosimeter (PNAD). The LLNL PNAD has periodically been tested using a Cf-252 neutron source, however until 2009, it was more than 25 years since the PNAD has been tested against a source of neutrons that arise from a reactor generated neutron spectrum that simulates a criticality. In October 2009, LLNL participated in an intercomparison of nuclear accident dosimeters at the CEA Valduc Silene reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison of nuclear accident dosimeters at CEA Valduc. The reactor generated neutron irradiations for the 2010 exercise were performed at the Caliban reactor. The Caliban results are described in this report. The procedure for measuring the nuclear accident dosimeters in the event of an accident has a solid foundation based on many experimental results and comparisons. The entire process, from receiving the activated NADs to collecting and storing them after counting was executed successfully in a field based operation. Under normal conditions at LLNL, detectors are ready and available 24/7 to perform the necessary measurement of nuclear accident components. Likewise LLNL maintains processing laboratories that are separated from the areas where measurements occur, but contained within the same facility for easy movement from processing area to measurement area. In the event of a loss of LLNL permanent facilities, the Caliban and previous Silene exercises have demonstrated that LLNL can establish field operations that will very good nuclear accident dosimetry results. There are still several aspects of LLNL's nuclear accident dosimetry program that have not been tested or confirmed. For instance, LLNL's method for using of biological samples (blood and hair) has not been verified since the method was first developed in the 1980's. Because LLNL and the other DOE

  8. Performance of the CEDS Accident Dosimetry System at the 1995 Los Alamos National Laboratory Nuclear Accident Dosimetry Intercomparison

    SciTech Connect

    McMahan, K.L.; Schwanke, L.J.

    1996-12-01

    In July 1995, LANL hosted an accident dosimetry intercomparison. When all reactors on the Oak Ridge Reservation were idled in 1988, the Health Physics Research Reactor (HPRR), which had been used for 22 previous intercomparisons dating from 1965, was shut down for an indefinite period. The LANL group began characterization of two critical assemblies for dosimetry purposes. As a result, NAD-23 was conceived and 10 DOE facilities accepted invitations to participate in the intercomparison. This report is a summary of the performance of one of the participants, the Centralized External Dosimetry System (CEDS). The CEDS is a cooperative personnel dosimetry arrangement between three DOE sites in Oak Ridge, Tennessee. Many successes and failures are reported herein. Generally, the TL dosimeters performed poorly and always over-reported the delivered dose. The TLD processing procedures contain efforts that would lead to large biases in the reported absorbed dose, and omit several key steps in the TLD reading process. The supralinear behavior of lithium fluoride (LiF) has not been characterized for this particular dosimeter and application (i.e., in high-dose mixed neutron/gamma fields). The use of TLD materials may also be precluded given the limitations of the LiF material itself, the TLD reading system, and the upper dose level to which accident dosimetry systems are required to perform as set forth in DOE regulations. The indium foil results confirm the expected inability of that material to predict the magnitude of the wearer`s dose reliably, although it is quite suitable as a quick-sort material. Biological sample (hair) results were above the minimum detectable activity (MDA) for only one of the tests. Several questions as to the best methods for sample handling and processing remain.

  9. The 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    NASA Astrophysics Data System (ADS)

    Swaja, R. E.; Greene, R. T.; Sims, C. S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12 to 16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. Participants measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results indicate that foil activation techniques are the most popular and accurate method of determining accident level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants used TLD's to determine gamma doses with very good results. Chemical dosimeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. Results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed.

  10. Results from 2010 Caliban Criticality Dosimetry Intercomparison

    SciTech Connect

    Veinot, K. G.

    2011-10-12

    The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

  11. INTERCOMPARISON OF RESULTS FOR A PWR ROD EJECTION ACCIDENT

    SciTech Connect

    DIAMOND,D.J.; ARONSON,A.; JO,J.; AVVAKUMOV,A.; MALOFEEV,V.; SIDOROV,V.; FERRARESI,P.; GOUIN,C.; ANIEL,S.; ROYER,M.E.

    1999-10-01

    This study is part of an overall program to understand the uncertainty in best-estimate calculations of the local fuel enthalpy during the rod ejection accident. Local fuel enthalpy is used as the acceptance criterion for this design-basis event and can also be used to estimate fuel damage for the purpose of determining radiological consequences. The study used results from neutron kinetics models in PARCS, BARS, and CRONOS2, codes developed in the US, the Russian Federation, and France, respectively. Since BARS uses a heterogeneous representation of the fuel assembly as opposed to the homogeneous representations in PARCS and CRONOS, the effect of the intercomparison was primarily to compare different intra-assembly models. Quantitative comparisons for core power, reactivity, assembly fuel enthalpy and pin power were carried out. In general the agreement between methods was very good providing additional confidence in the codes and providing a starting point for a quantitative assessment of the uncertainty in calculated fuel enthalpy using best-estimate methods.

  12. Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

    PubMed

    Romanyukha, Alexander; King, David L; Kennemur, Lisa K

    2012-05-01

    After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations

  13. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    SciTech Connect

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed.

  14. Determination of possible damage/degradation of the Sandia National Laboratories Personal Nuclear Accident Dosimeter (PNAD).

    SciTech Connect

    Potter, Charles Augustus; Ward, Dann C.

    2008-05-01

    This report describes the results of an inspection performed on the existing stock of SNL Personal Nuclear Accident Dosimeters (PNADs). The current stock is approximately 20 years old, and has not been examined since their initial acceptance. A small random sample of PNADs were opened (a destructive process) and the contents visually examined. Sample contents were not degraded and indicate that the existing stock of SNL PNADs is acceptable for continued use.

  15. Design of an advanced TLD-based fixed nuclear accident dosimeter

    SciTech Connect

    Casson, W.H.; Mei, G.T.

    1993-08-01

    A new system has been designed for use as a fixed nuclear accident dosimeter based upon the thermoluminescent dosimeter (TLD) system used for personnel dosimetry at US Department of Energy facilities managed by Martin Marietta Energy Systems, Inc. The system is made up of a small phantom consisting of two main parts measuring 20 x 20 x 5 cm and made from polymethylmethacrylate. A neutron-sensitive TLD card is placed in the center between the two pieces. Also, TLD cards in standard holders are mounted on the front and back of the phantom. A derivation is made of a linear combination of the responses from the TLD elements which results in calculation of the neutron fluence, absorbed dose, and dose equivalent. By using the right linear combinations, a crude spectrum can be estimated, which allows further calculation of the average fluence-to-dose-equivalent conversion factor. The response of the system was tested and found to be applicable for the evaluation of typical nuclear accident spectra, although considerable improvement can be made by the addition of a sulfur pellet. The system was also tested for angular dependence. In order to move the development of this system from the proof-of-principle to full application, the calculation of the TLD resonse curves must be improved, additional measurements must be made, and the system must be tested in a simulated accident neutron field. The advantages of the new fixed dosimeter system are its simplicity, easy maintenance, and lower operational cost. The system uses standard TLD cards that are already in place throughout Energy Systems facilities. The TLD process personnel are famliiar with evaluating doses from TLDs and can provide information necessary to ensure timely and accurate assessment of exposures that may result from riticality accidents. Most of the quality control requirements are part of the existing personnel dosimetry system.

  16. Twenty-first nuclear accident dosimetry intercomparison study, August 6-10, 1984

    SciTech Connect

    Swaja, R.E.; Ragan, G.E.; Sims, C.S.

    1985-05-01

    The twenty-first in a series of nuclear accident dosimetry (NAD) intercomparison (NAD) studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 6-10, 1984. The Health Physics Research Reactor operated in the pulse mode was used to simulate three criticality accidents with different radiation fields. Participants from five organizations measured neutron doses between 0.53 and 4.36 Gy and gamma doses between 0.19 and 1.01 Gy at area monitoring stations and on phantoms. About 75% of all neutron dose estimates based on foil activation, hair activation, simulated blood sodium activation, and thermoluminescent methods were within +-25% of reference values. Approximately 86% of all gamma results measured using thermoluminescent (TLD-700 or CaSO/sub 4/) systems were within +-20% of reference doses which represents a significant improvement over previous studies. Improvements observed in the ability of intercomparison participants to estimate neutron and gamma doses under criticality accident conditions can be partly attributed to experience in previous NAD studies which have provided practical tests of dosimetry systems, enabled participants to improve evaluation methods, and standardized dose reporting conventions. 16 refs., 15 tabs.

  17. 1987 Neutron and gamma personnel dosimeter intercomparison study using a D/sub 2/O-moderated /sup 252/Cf source

    SciTech Connect

    Swaja, R.E.; West, L.E.; Sims, C.S.; Welty, T.J.

    1989-05-01

    The thirteenth Personnel Dosimetry Intercomparison Study (i.e., PDIS 13) was conducted during April 1987 as a joint effort by Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research Group and the Southwest Radiation Calibration Center at the University of Arkansas. A total of 48 organizations (34 from the US and 14 from abroad) participated in PDIS 13. Participants submitted a total of 1,113 neutron and gamma dosimeters for this mixed field study. The dosimeters were transferred by mail and were handled by experimental personnel at ORNL and the University of Arkansas. The type of neutron dosimeter and the percentage of participants submitting that type are as follows: TLD-albedo (49%), direct interaction TLD (31%), CR-39 (17%), film (3%). The type of gamma dosimeter and the percentage of participants submitting that type are as follows: Li/sub 2/B/sub 4/O/sub 7/, alone or in combination with CaSO/sub 4/, (69%), /sup 7/LiF (28%), natural LiF (3%). Radiation exposures in PDIS 13 were limited to 0.5 and 1.5 mSv from /sup 252/Cf moderated by 15-cm of D/sub 2/O. Traditional exposures using the Health Physics Research Reactor (HPRR) were not possible due to the fact that all reactors at ORNL, including the HPRR, were shutdown by order of the Department of Energy at the time the intercomparison was performed. Planned exposures using a /sup 238/PuBe source were negated by a faulty timing mechanism. Based on accuracy and precision, direct interaction TLD dosimeters exhibited the best performance in PDIS 13 neutron measurements. They were followed, in order of best performance, by CR-39, TLD albedo, and film. The Li/sub 2/B/sub 4/O/sub 7/ type TLD dosimeters exhibited the best performance in PDIS 13 gamma measurements. They were followed by natural LiF, /sup 7/LiF, and film. 12 refs., 1 fig., 5 tabs.

  18. Evaluation of the response to xenon-133 radiations by thermoluminescent dosimeters used during the accident at Three Mile Island.

    PubMed

    Riley, R J; Zanzonico, P B; Masterson, M E; St Germain, J M; Laughlin, J S

    1982-03-01

    An evaluation is presented of the accuracy and sensitivity of three types of TLD's used during the accident at the Three Mile Island Nuclear Station. This evaluation indicated that, due to the method of calibration, all the dosimeters over-responded to 133Xe radiations. The response ranged from slightly above unity to almost two. Exposures of the TLD's were of two types, namely, the characteristic X-rays either were or were not filtered from the beam. The angular sensitivity of the dosimeters is also reported. PMID:7068394

  19. Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.

    PubMed

    Médioni, R; Asselineau, B; Verrey, B; Trompier, F; Itié, C; Texier, C; Muller, H; Pelcot, G; Clairand, I; Jacquet, X; Pochat, J L

    2004-01-01

    In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue. PMID:15353686

  20. The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.

    PubMed

    Gualdrini, G; Bedogni, R; Fantuzzi, E; Mariotti, F

    2004-01-01

    The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry Systems' (Silène reactor, IRSN-CEA-Valduc June 2002). The evaluation of the neutron spectra and the neutron dosimetric quantities relies on activation detectors and on unfolding algorithms. Thermoluminescent detectors are employed for the gamma dose measurement. The work is aimed at accurately characterising the measurement system and, at the same time, testing the algorithms. Useful spectral information were included, based on Monte Carlo simulations, to take into account the potential accident scenarios of practical interest. All along this exercise intercomparison a particular attention was devoted to the 'traceability' of all the experimental and computational parameters and therefore, aimed at an easy treatment by the user. PMID:15353692

  1. Intercomparison of environmental gamma doses measured with A NaI (Tl) survey meter and thermoluminescent dosimeters (TLDs) in the Poonch division of Azad Kashmir, Pakistan.

    PubMed

    Rafique, Muhammad; Kearfott, Kimberlee J; Ahmad, Khalil; Akhter, Jabeen; Khan, Abdul Razzaq; Saeed, Raja Azhar; Rahman, Saeed Ur; Matiullah; Rajput, Muhammad Usman

    2014-12-01

    This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a NaI (Tl) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. During three distinct two month time periods within the six month study period, all the installed dosimeters were exposed to outdoor environmental gamma radiations, retrieved and read out at Radiation Dosimetry Laboratory, Health Physics Division, PINSTECH laboratory, Islamabad. The ambient outdoor gamma dose rate measurements were also taken with NaI (Tl) based portable radiometric instrument at 1 m above the ground. To estimate the annual gamma doses, NaI (Tl) based survey data were used for one complete year following the deployment of the dosimeters. The mean annual gamma dose rates measured by TLDs and survey meter were found as 1.47±0.10 and 0.862±0.003 mGy/y respectively. Taking into account a 29% outdoor occupancy factor, the annual average effective dose rate for individuals was estimated as 0.298±0.04 and 0.175±0.03 mSv/y by TLDs and survey meter, respectively. For outdoor exposure, the ELCR was calculated from the TLD and survey meter measurements. The environmental outdoor average annual effective dose obtained in present study are less than the estimated world average terrestrial and cosmic gamma ray dose rate of 0.9 mSv/y reported in UNSCEAR 2000. The possible origins of gamma doses in the area and incompatibilities of results obtained from the two different measurement techniques are also discussed. PMID:25484014

  2. Reference dosimetry measurements for the international intercomparison of criticality accident dosimetry SILENE 9-21 June 2002.

    PubMed

    Asselineau, B; Trompier, F; Texier, C; Itié, C; Médioni, R; Tikunov, D; Muller, H; Pelcot, G

    2004-01-01

    An international intercomparison of criticality accident dosimetry systems took place in the SILENE reactor, in June 2002. Participants from 60 laboratories irradiated their dosemeters (physical and biological) using two different configurations of the reactor. In preparation for this intercomparison, the leakage radiation fields were characterised by spectrometry and dosimetry measurements using the ROSPEC spectrometer associated with a NE-213 scintillator, ionisation chambers, GM counters, diodes and thermoluminescence dosemeters (TLDs). For this intercomparison, a large area was required to irradiate the dosemeters both in free air and on phantoms. Therefore, measurements of the uniformity of the field were performed with activation detectors and TLDs for neutron and gammas, respectively. This paper describes the procedures used and the results obtained. PMID:15353691

  3. Personal nuclear accident dosimetry at Sandia National Laboratories

    SciTech Connect

    Ward, D.C.; Mohagheghi, A.H.; Burrows, R.

    1996-09-01

    DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.

  4. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario.

    PubMed

    Vives I Batlle, J; Beresford, N A; Beaugelin-Seiller, K; Bezhenar, R; Brown, J; Cheng, J-J; Ćujić, M; Dragović, S; Duffa, C; Fiévet, B; Hosseini, A; Jung, K T; Kamboj, S; Keum, D-K; Kryshev, A; LePoire, D; Maderich, V; Min, B-I; Periáñez, R; Sazykina, T; Suh, K-S; Yu, C; Wang, C; Heling, R

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of (90)Sr, (131)I and (137)Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters. PMID:26717350

  5. EPR study of free radicals in cotton fiber for its potential use as a fortuitous dosimeter in radiological accidents

    NASA Astrophysics Data System (ADS)

    Sudprasert, W.; Insuan, P.; Khamkhrongmee, S.

    2015-05-01

    Electron paramagnetic resonance (EPR) spectroscopy was applied to characterize radiation-induced free radicals in the cotton fiber in order to determine the possibility for using cotton as a fortuitous dosimeter in accidental exposures to radiation. Cotton fabrics were irradiated at 0.1, 0.5, 1, 2, 10, 50 and 500 Gy using a 137Cs gamma source. The irradiated samples were then stored in the dark under controlled environmental conditions for 1, 15, 35 and 60 days. The EPR spectra were observed in samples using a Bruker EMX X-band spectrometer equipped with a TE102 rectangular cavity. The EPR signal intensities of irradiated samples were determined from peak-to-peak amplitudes of EPR spectra and compared to those of unirradiated samples. The following optimum parameters were used: 100 kHz modulation frequency, 9.84 GHz microwave frequency, 1.8 mT modulation amplitude, 1.0 mW microwave power, 655 ms time constant, 41 ms conversion time and 41.98 s sweep time. The EPR spectra of unirradiated samples showed a singlet line with g = 2.006 due to pre-existing stable organic radicals in the cotton fibers, whereas those of irradiated samples showed the same pattern with different signal intensities according to the doses. Irradiation increased the signal intensity in a dose dependent manner. The signal intensity exhibited an exponential decay with storage time from 1 to 60 days. Obviously, the degree of fading of EPR intensity did not depend on the absorbed dose from 0.1 - 50 Gy. The maximum fading was about 60% at 60 days of storage for irradiated samples at all doses. However, this post-irradiation signal appeared to be detectable for up to 60 days. The EPR study results indicated the potential of using cotton as a fortuitous dosimeter in radiological accidents.

  6. Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France.

    SciTech Connect

    Ward, Dann C.

    2011-09-01

    This document describes the personal nuclear accident dosimeter (PNAD) used by Sandia National Laboratories (SNL) and presents PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study held 20-23 September, 2010, at CEA Valduc, France. SNL PNADs were exposed in two separate irradiations from the CALIBAN reactor. Biases for reported neutron doses ranged from -15% to +0.4% with an average bias of -7.7%. PNADs were also exposed on the back side of phantoms to assess orientation effects.

  7. Radiation dosimeters

    DOEpatents

    Hoelsher, James W.; Hegland, Joel E.; Braunlich, Peter F.; Tetzlaff, Wolfgang

    1992-01-01

    Radiation dosimeters and dosimeter badges. The dosimeter badges include first and second parts which are connected to join using a securement to produce a sealed area in which at least one dosimeter is held and protected. The badge parts are separated to expose the dosimeters to a stimulating laser beam used to read dose exposure information therefrom. The badge is constructed to allow automated disassembly and reassembly in a uniquely fitting relationship. An electronic memory is included to provide calibration and identification information used during reading of the dosimeter. Dosimeter mounts which reduce thermal heating requirements are shown. Dosimeter constructions and production methods using thin substrates and phosphor binder-layers applied thereto are also taught.

  8. Performance testing of extremity dosimeters

    SciTech Connect

    Harty, R.; Reece, W.D.; Hooker, C.D.

    1987-06-01

    The Health Physics Society Standing Committee (HPSSC) Working Group on Performance Testing of Extremity Dosimeters has issued a draft of a proposed standard for extremity dosimeters. The draft standard proposes methods to be used for testing dosimetry systems that determine occupational radiation dose to the extremities and the performance criterion used to determine compliance. The draft standard has been evaluated by testing the performance of existing processors of extremity dosimeters against the standard's proposed criterion. The proposed performance criterion is: absolute value of B + S less than or equal to 0.35, where B is the bias (calculated as the average of the performance quotients) of 15 dosimeter measurements and S is the standard deviation of the performance quotients. Dosimeter performance was tested in seven irradiation categories: low-energy photons (general and accident dosimetry), high-energy photons (general and accident dosimetry), beta particles, neutrons, and a mixture category. Twenty-one types of extremity dosimeters (both finger ring and wrist/ankle dosimeters) were received from 11 processors. The dosimeters were irradiated by the Pacific Northwest Laboratory (PNL) to specific dose levels in one or more of the seven categories as specified in the draft standard and were returned to the processors. The processors evaluated the doses and returned the results to PNL for analysis. The results were evaluated against the performance criterion specified in the draft standard. The results indicate that approximately 60% of both the finger ring and the wrist/ankle dosimeters met the performance criterion. Two-thirds of the dosimeters that did not meet the performance criterion had large biases (ranging from 0.25 to 0.80) but small standard deviations (less than 0.15). 21 refs., 3 figs., 20 tabs.

  9. Wristwatch dosimeter

    DOEpatents

    Wolf, M.A.; Waechter, D.A.; Umbarger, C.J.

    1986-08-26

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable with a conventional digital watch case having an additional aperture enabling the detector to receive radiation. 10 figs.

  10. Wristwatch dosimeter

    DOEpatents

    Wolf, Michael A.; Waechter, David A.; Umbarger, C. John

    1986-01-01

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable with a conventional digital watch case having an additional aperture enabling the detector to receive radiation.

  11. Kevlar® as a Potential Accident Radiation Dosimeter for First Responders, Law Enforcement and Military Personnel.

    PubMed

    Romanyukha, Alexander; Trompier, François; Benevides, Luis A

    2016-08-01

    Today the armed forces and law enforcement personnel wear body armor, helmets, and flak jackets composed substantially of Kevlar® fiber to prevent bodily injury or death resulting from physical, ballistic, stab, and slash attacks. Therefore, there is a high probability that during a radiation accident or its aftermath, the Kevlar®-composed body armor will be irradiated. Preliminary study with samples of Kevlar® foundation fabric obtained from body armor used by the U.S. Marine Corps has shown that all samples evaluated demonstrated an EPR signal, and this signal increased with radiation dose. Based on these results, the authors predict that, with individual calibration, exposure at dose above 1 Gy can be reliably detected in Kevlar® samples obtained from body armor. As a result of these measurements, a post-event reconstruction of exposure dose can be obtained by taking various samples throughout the armor body and helmet worn by the same irradiated individual. The doses can be used to create a whole-body dose map that would be of vital importance in a case of a partial body or heterogeneous exposure. PMID:27356056

  12. Citizen's dosimeter

    SciTech Connect

    Klemic, Gladys; Bailey, Paul; Breheny, Cecilia

    2008-09-02

    The present invention relates to a citizen's dosimeter. More specifically, the invention relates to a small, portable, personal dosimetry device designed to be used in the wake of a event involving a Radiological Dispersal Device (RDD), Improvised Nuclear Device (IND), or other event resulting in the contamination of large area with radioactive material or where on site personal dosimetry is required. The card sized dosimeter generally comprises: a lower card layer, the lower card body having an inner and outer side; a upper card layer, the layer card having an inner and outer side; an optically stimulated luminescent material (OSLM), wherein the OSLM is sandwiched between the inner side of the lower card layer and the inner side of the upper card layer during dosimeter radiation recording, a shutter means for exposing at least one side of the OSLM for dosimeter readout; and an energy compensation filter attached to the outer sides of the lower and upper card layers.

  13. Description and evaluation of the Hanford personnel dosimeter program from 1944 through 1989. [Contain Glossary

    SciTech Connect

    Wilson, R.H.; Fix, J.J.; Baumgartner, W.V.; Nichols, L.L.

    1990-09-01

    This report describes the evolution of personnel dosimeter technology at Hanford since the inception of Hanford operations in 1944. Each of the personnel dosimeter systems used by people working or visiting Hanford is described. In addition, the procedures used to calibrate and calculate dose for each of the dosimeter systems are described. The accuracy of the recorded dose, primarily whole body deep dose, for the different dosimeter systems is evaluated. The evaluation is based on an extensive review of historical literature, as well as a 1989 intercomparison study of all film dosimeters and performance testing of the thermoluminescent dosimeter, also conducted during 1989. 73 refs., 40 figs., 41 tabs.

  14. PERSONNEL DOSIMETER

    DOEpatents

    Birkhoff, R.D.; Hubbell, H.H. Jr.; Johnson, R.M.

    1959-02-24

    A personnel dosimeter sensitive to both gamma and beta radiation is described. The dosimeter consists of an electrical conductive cylinder having a wall thickness of substantially 7 milligrams per square centimeter and an electrode disposed axially within the cylinder and insulated therefrom to maintain a potential impressed between the electrode and the cylinder. A cylindrical perforated shield provided with a known percentage of void area is disposed concentrically about the cylinder. The shield is formed of a material which does not contain more than 15 percent of an element higher than atomic weight 13. The dose actually received is at most the gamma dose plus the beta dose indicated by discharge of the dosimeter divided by the known percentage.

  15. RADIATION DOSIMETER

    DOEpatents

    Balkwell, W.R. Jr.; Adams, G.D. Jr.

    1960-05-10

    An improvement was made in the determination of amounts of ionizing radiation, particularly low-energy beta particles of less than 1000 rad total dose by means of fluid-phase dosimeter employing a stabilized-- sensitized ferrous-ferric colorimetric system in a sulphuric acid medium. The improvement in the dosimeter consists of adding to the ferrous-ferric system in concentrations of 10/sub -2/ to 10/sup -4/M an organic compound having one or more carboxylic or equivalent groups, such compounds being capable of chelating or complexing the iron ions in the solution. Suitable sensitizing and stabilizing agents are benzoic, phthalic, salicylic, malonic, lactic, maleic, oxalic, citric, succinic, phenolic tartaric, acetic, and adipic acid, as well as other compounds which are added to the solution alone or in certain combinations. As in conventional fluid-phase dosimeters, the absorbed dosage is correlated with a corresponding change in optical density at particular wavelengths of the solution.

  16. LLNL Results from CALIBAN-PROSPERO Nuclear Accident Dosimetry Experiments in September 2014

    SciTech Connect

    Lobaugh, M. L.; Hickman, D. P.; Wong, C. W.; Wysong, A. R.; Merritt, M. J.; Heinrichs, D. P.; Topper, J. D.

    2015-05-21

    Lawrence Livermore National Laboratory (LLNL) uses thin neutron activation foils, sulfur, and threshold energy shielding to determine neutron component doses and the total dose from neutrons in the event of a nuclear criticality accident. The dosimeter also uses a DOELAP accredited Panasonic UD-810 (Panasonic Industrial Devices Sales Company of America, 2 Riverfront Plaza, Newark, NJ 07102, U.S.A.) thermoluminescent dosimetery system (TLD) for determining the gamma component of the total dose. LLNL has participated in three international intercomparisons of nuclear accident dosimeters. In October 2009, LLNL participated in an exercise at the French Commissariat à l’énergie atomique et aux énergies alternatives (Alternative Energies and Atomic Energy Commission- CEA) Research Center at Valduc utilizing the SILENE reactor (Hickman, et.al. 2010). In September 2010, LLNL participated in a second intercomparison at CEA Valduc, this time with exposures at the CALIBAN reactor (Hickman et al. 2011). This paper discusses LLNL’s results of a third intercomparison hosted by the French Institut de Radioprotection et de Sûreté Nucléaire (Institute for Radiation Protection and Nuclear Safety- IRSN) with exposures at two CEA Valduc reactors (CALIBAN and PROSPERO) in September 2014. Comparison results between the three participating facilities is presented elsewhere (Chevallier 2015; Duluc 2015).

  17. Thermoluminescence dosimeter

    SciTech Connect

    Zendle, Robert

    1985-01-01

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  18. Thermoluminescence dosimeter

    DOEpatents

    Zendle, R.

    1983-11-03

    A thermoluminescence dosimeter having a very small rate of decline of sensitivity during subsequent uses after heating is disclosed. The dosimeter includes a detector crystal and a glass enclosure in which the detector crystal is located. The glass enclosure is air tight and is filled with a super dry inert fill gas. The inert fill gas is nonreactive with the detector crystal when the detector crystal is heated to thermoluminescence. The fill gas is selected from the group consisting of air, nitrogen, and argon, suitable admixed with 5 to 25 percent helium. The detector crystal consists essentially of calcium fluoride. The fill gas is preferably contained at a subatmospheric pressure in the glass enclosure.

  19. Composite material dosimeters

    DOEpatents

    Miller, Steven D.

    1996-01-01

    The present invention is a composite material containing a mix of dosimeter material powder and a polymer powder wherein the polymer is transparent to the photon emission of the dosimeter material powder. By mixing dosimeter material powder with polymer powder, less dosimeter material is needed compared to a monolithic dosimeter material chip. Interrogation is done with excitation by visible light.

  20. Fundamentals of gel dosimeters

    NASA Astrophysics Data System (ADS)

    McAuley, K. B.; Nasr, A. T.

    2013-06-01

    Fundamental chemical and physical phenomena that occur in Fricke gel dosimeters, polymer gel dosimeters, micelle gel dosimeters and genipin gel dosimeters are discussed. Fricke gel dosimeters are effective even though their radiation sensitivity depends on oxygen concentration. Oxygen contamination can cause severe problems in polymer gel dosimeters, even when THPC is used. Oxygen leakage must be prevented between manufacturing and irradiation of polymer gels, and internal calibration methods should be used so that contamination problems can be detected. Micelle gel dosimeters are promising due to their favourable diffusion properties. The introduction of micelles to gel dosimetry may open up new areas of dosimetry research wherein a range of water-insoluble radiochromic materials can be explored as reporter molecules.

  1. Pocket radiation dosimeter--dosimeter charger assembly

    DOEpatents

    Manning, Frank W.

    1984-01-01

    This invention is a novel pocket-type radiation dosimeter comprising an electrometric radiation dosimeter and a charging circuit therefor. The instrument is especially designed to be amenable to mass production, to have a long shelf life, and to be compact, lightweight, and usable by the layman. The dosimeter proper may be of conventional design. The charging circuit includes a shake-type electrostatic generator, a voltage doubler for integrating generator output voltages of one polarity, and a switch operated by an external permanent magnet.

  2. Pocket radiation dosimeter: dosimeter charger assembly

    DOEpatents

    Manning, F.W.

    1982-03-17

    This invention is a novel pocket-type radiation dosimeter comprising an electrometric radiation dosimeter and a charging circuit therefor. The instrument is especially designed to be amenable to mass production, to have a long shelf life, and to be compact, lightweight, and usable by the layman. The dosimeter proper may be of conventional design. The charging circuit includes a shake-type electrostatic generator, a voltage doubler for integrating generator output voltages of one polarity, and a switch operated by an external permanent magnet.

  3. Fifth personnel dosimetry intercomparison study

    SciTech Connect

    Sims, C.S.

    1980-02-01

    The fifth Personnel Dosimetry Intercomparison Study (PDIS) was conducted at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research (DOSAR) facility on March 20-22, 1979. This study is the latest PDIS in the continuing series started at the DOSAR facility in 1974. The PDIS is a three day study, typically in March, where personnel dosimeters are mailed to the DOSAR facility, exposed to a range of low-level neutron radiation doses (1 to 15 mSv or equivalently, 100 to 1500 mrem) and neutron-to-gamma ratios (1:1-10:1) using the Health Physics Research Reactor (HPRR) as the radiation source, and returned to the participants for evaluation. This report is a summary and analysis of the results reported by the various participants. The participants are able to intercompare their results with those of others who made dose measurements under identical experimental conditions.

  4. Smart Radiological Dosimeter

    SciTech Connect

    Kosslow, William J.; Bandzuch, Gregory S.

    2004-07-20

    A radiation dosimeter providing an indication of the dose of radiation to which the radiation sensor has been exposed. The dosimeter contains features enabling the monitoring and evaluating of radiological risks so that a user can concentrate on the task at hand. The dosimeter provides an audible alarm indication that a predetermined time period has elapsed, an audible alarm indication reminding the user to check the dosimeter indication periodically, an audible alarm indicating that a predetermined accumulated dose has been prematurely reached, and an audible alarm indication prior or to reaching the 3/4 scale point.

  5. Micromechanical radiation dosimeter

    SciTech Connect

    Thundat, T.; Sharp, S.L.; Fisher, W.G.; Warmack, R.J.; Wachter, E.A. )

    1995-03-20

    We demonstrate the use of microcantilevers coated with ultraviolet cross-linking polymers as optical radiation dosimeters. Upon exposure to radiation, a treated cantilever bends due to stress and its resonance frequency increases due to stiffening. These phenomena can be used to develop sensitive radiation dosimeters which respond to radiation affecting the mechanical properties of the selected coating.

  6. Wrist-watch dosimeter

    DOEpatents

    Wolf, M.A.; Waechter, D.A.; Umbarger, C.J.

    1982-04-16

    The disclosure is directed to a wristwatch dosimeter utilizing a CdTe detector, a microprocessor and an audio and/or visual alarm. The dosimeter is entirely housable within a conventional digital watch case having an additional aperture enabling the detector to receive radiation.

  7. Performance testing of extremity dosimeters against a draft standard

    SciTech Connect

    Harty, R.; Reece, W.D.; Hooker, C.D.; McDonald, J.C.

    1990-09-01

    The assurance of worker radiation safety is directly related to the performance of personnel dosimetry. The US Department of Energy (DOE) has long recognized this critical relationship and has addressed this issue by instituting the DOE Laboratory Accreditation Program (DOELAP) which strives to improve the quality of personnel dosimetry through performance testing, dosimetry calibration, intercomparisons, evaluations and accreditations. One area of personnel dosimetry that has not been specifically addressed by DOELAP is extremity dosimeter testing. This task was directed at assessing the problems of implementing extremity dosimeter performance testing. A series of performance tests were made based on a draft standard written by the Health Physics Society Standards Committee (HPSSC) using extremity dosimeters currently in use at DOE and DOE contractor facilities. The results of this study indicate the need to incorporate performance testing of extremity dosimetry systems into DOELAP. Based on the results of this study, recommendations are made for improvements to the draft standard. 20 refs., 6 figs., 3 tabs.

  8. Microwave dosimeter - A concept

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G.; Bird, F.

    1971-01-01

    Dosimeter determines time-integrated radiation dosage to which an individual is exposed. Integration is measured chemically in proportion to radiation detected. Wearer receives an exposure measurement representing an average of the dose over the entire body.

  9. ULTRASONIC NEUTRON DOSIMETER

    DOEpatents

    Truell, R.; de Klerk, J.; Levy, P.W.

    1960-02-23

    A neutron dosimeter is described which utilizes ultrasonic waves in the megacycle region for determination of the extent of neutron damage in a borosilicate glass through ultrasonic wave velocity and attenuation measurements before and after damage.

  10. Magnetic field dosimeter development

    SciTech Connect

    Lemon, D.K.; Skorpik, J.R.; Eick, J.L.

    1980-09-01

    In recent years there has been increased concern over potential health hazards related to exposure of personnel to magnetic fields. If exposure standards are to be established, then a means for measuring magnetic field dose must be available. To meet this need, the Department of Energy has funded development of prototype dosimeters at the Battelle Pacific Northwest Laboratory. This manual reviews the principle of operation of the dosimeter and also contains step-by-step instructions for its operation.

  11. Ozone intercomparisons from the Balloon Intercomparison Campaign

    NASA Astrophysics Data System (ADS)

    Robbins, D.; Evans, W.; Louisnard, N.; Pollitt, S.; Traub, W.; Waters, J.

    Intercomparisons of remote and in-situ techniques used to measure stratospheric ozone are made using results obtained on the Balloon Intercomparison Campaign of 1982 and 1983. Two in-situ and four remote instruments participated. These included ECC ozonesondes, a UV absorption photometer, and microwave emission, IR emission, and absorption spectrometers. Differences are generally less than 15 percent, and are within the quoted error bars. Flights which involved different sets of instruments were made on four separate days, and results are intercompared in plots of ozone density versus altitude. A careful assessment of errors was made for each instrument, and a plot of absolute errors versus altitude is given.

  12. Length of stain dosimeter

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    1994-01-01

    Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

  13. Fundamentals of Polymer Gel Dosimeters

    NASA Astrophysics Data System (ADS)

    McAuley, Kim B.

    2006-12-01

    The recent literature on polymer gel dosimetry contains application papers and basic experimental studies involving polymethacrylic-acid-based and polyacrylamide-based gel dosimeters. The basic studies assess the relative merits of these two most commonly used dosimeters, and explore the effects of tetrakis hydroxymethyl phosphonium chloride (THPC) antioxidant on dosimeter performance. Polymer gel dosimeters that contain THPC or other oxygen scavengers are called normoxic dosimeters, because they can be prepared under normal atmospheric conditions, rather than in a glove box that excludes oxygen. In this review, an effort is made to explain some of the underlying chemical phenomena that affect dosimeter performance using THPC, and that lead to differences in behaviour between dosimeters made using the two types of monomer systems. Progress on the development of new more effective and less toxic dosimeters is also reported.

  14. Fact-finding Survey in Response to the Manipulation of Personal Alarm Dosimeter Collection Efficiency: Lessons Learned About Post-Emergency Radiation Protection from the TEPCO Fukushima Daiichi APP Accident.

    PubMed

    Yasui, Shojiro

    2015-01-01

    During emergency work at TEPCO Fukushima Daiichi Atomic Power Plant on December 1, 2011 a subcontractor demanded that its contracted workers cover their personal alarm dosimeters (PAD) with 3-cm-thick lead plates to lower dosimeter readings. As a response, the Ministry of Health, Labour and Welfare (MHLW) conducted a fact-finding survey to identify similar cases and devise measures to prevent a recurrence of this incident. To screen the suspected cases, the MHLW extracted: a) cases in which a PAD reading was at least 15% higher than the reading obtained from a radio-photolumine-scence dosimeter (RPD), where the dose was greater than 5 mSv in a month (1813 data points), and b) dose data in which PAD readings were less than 50% of the expected dose, where exposure dose may exceed 1 mSv in a day (56 workers, 17,148 data points). From these screenings, the MHLW identified 50 instances from TEPCO and nine primary contractors, including four general contractors, two plant manufacturers, and three plant maintenance companies as the subjects of the due diligence study of exposure data, including interviews. The results of the survey provide lessons that can also be applied to transition from emergency radiation protection to normal operation, as the application of emergency dose limits had ceased on December 16, 2011, in the affected plant. Based on the results of the survey, the MHLW provided administrative guidance documents to TEPCO and 37 primary contractors. The major points of these documents include: a) identification of recorded dose values by comparison of PAD readings to RPD readings, b) storage and management of RPDs and control badges, c) circulation management of PADs and access control to the affected plant, d) estimation of planned doses and setting of alarm values of PADs, e) actions to be taken by contractors if worker dose limits are reached, and f) physical measures to prevent recurrence of the incident. PMID:25617063

  15. Dose equivalent neutron dosimeter

    DOEpatents

    Griffith, Richard V.; Hankins, Dale E.; Tomasino, Luigi; Gomaa, Mohamed A. M.

    1983-01-01

    A neutron dosimeter is disclosed which provides a single measurements indicating the amount of potential biological damage resulting from the neutron exposure of the wearer, for a wide range of neutron energies. The dosimeter includes a detecting sheet of track etch detecting material such as a carbonate plastic, for detecting higher energy neutrons, and a radiator layer containing conversion material such as .sup.6 Li and .sup.10 B lying adjacent to the detecting sheet for converting moderate energy neutrons to alpha particles that produce tracks in the adjacent detecting sheet. The density of conversion material in the radiator layer is of an amount which is chosen so that the density of tracks produced in the detecting sheet is proportional to the biological damage done by neutrons, regardless of whether the tracks are produced as the result of moderate energy neutrons striking the radiator layer or as the result of higher energy neutrons striking the sheet of track etch material.

  16. [Thermoluminescence Slab Dosimeter].

    PubMed

    Shinsho, Kiyomitsu; Koba, Yusuke; Tamatsu, Satoshi; Sakurai, Noboru; Wakabayashi, Genichiro; Fukuda, Kazusige

    2013-01-01

    In 1953 F. Daniels et al. used the property of thermoluminescence in dosimetry for the first time. Since then, numerous TLD have been developed. 2D TLD was investigated for the first time in 1972 by P Broadhead. However, due to excessive fading, difficulties with handling and the time required for measurements, development stalled. At the current time, the majority of TLD are used in small scale, localized dosimetry with a wide dynamic range and personal dosimeters for exposure management. Urushiyama et. al. have taken advantage of the commoditization of CCD cameras in recent years--making large area, high resolution imaging easier--to introduce and develop a 2D TLD. It is expected that these developments will give rise to a new generation of applications for 2D TL dosimetry. This paper introduces the "TL Slab Dosimeter" developed jointly by Urushiyama et. al. and our team, its measurement system and several typical usage scenarios. PMID:24893451

  17. Dosimeter Badge Detects Hydrazines

    NASA Technical Reports Server (NTRS)

    Young, Rebecca C.; Travis, Joshua C.; Moore, Gerald; Rose-Pehrsson, Susan; Carver, Patricia; Brenner, Karen

    1993-01-01

    Disposable dosimeter badge indicates approximate cumulative exposure to hydrazine or monomethyl hydrazine in air. Indication is change in colors of both paper tapes; one coated with para-N, N-dimethylaminobenzaldehyde. Colors of exposed tapes compared with colors on two preprinted color wheels to obtain estimate of exposure. Badges help minimize risks associated with exposure of personnel to hydrazine or monomethyl hydrazine, or suspected carcinogens. Also used as stationary monitors by taping them on walls or equipment at strategic locations.

  18. Optical waveguide dosimeter

    SciTech Connect

    Kronenberg, S.; Levine, H.; Mclaughlin, W.L.; Siebentritt, C.R.

    1983-03-22

    An optical waveguide dosimeter for personnel dosimetry is provided including a liquid solution of leuko dye hermetically sealed in plastic tubing. Optical transport is improved by dipping the ends of the plastic tubing into clear epoxy, thus forming beads that serve as optical lenses. A layer of clear ultraviolet absorbing varnish coated on these beads and an opaque outer layer over the plastic tubing provides protection against ambient uv.

  19. The Development of a Beta-Gamma Personnel Dosimeter

    NASA Astrophysics Data System (ADS)

    Tsakeres, Frank Steven

    The assessment of absorbed dose in mixed beta and gamma radiation fields is an extremely complex task. For many years, the assessment of the absorbed dose to tissue from the weakly penetrating components of a radiation field (i.e., beta particles, electrons) has been largely ignored. Beta radiation fields are encountered routinely in a nuclear facility and may represent the major radiation component under certain accident or emergency conditions. Many attempts have been made to develop an accurate mixed field personnel dosimeter. However, all of these dosimeters have exhibited numerous response problems which have limited their usefulness for personnel dose assessment. Consequently, the determination of the absorbed dose at the epidermal depth (i.e., 7 mg/cm('2)) has been difficult to measure accurately. The objective of this research project was to design, build, and test a sensitive and accurate personnel dosimeter for mixed field applications. The selection of the various dosimeter elements were determined by evaluating several types of phosphors, filters, and backscatter materials. After evaluating the various response characteristics of the badge components, a prototype dosimeter, the CHEMM (CaF(,2):Dy Highly Efficient Multiple Element Multiple Filter) personnel dosimeter, was developed and tested at Georgia Tech, Emory University and the National Bureau of Standards. This dosimeter was comprised of four large CaF(,2):Dy (TLD-200) TLD's and a standard LiF (TLD-100) chip. The weakly penetrating and penetrating components of a radiation field were separated using a series of TLD/filter combinations and a new dose assessment algorithm. The large TLD-200 chips, along with a series of tissue-equivalent filters, were used to determine the absorbed dose due to the weakly penetrating radiation while a LiF/filter combination was used to measure the penetrating component. In addition, a new backscatter material was included in the badge design to better simulate a

  20. Instrument intercomparisons and assessments

    NASA Astrophysics Data System (ADS)

    Albritton, D. L.; Zander, R. J.; Farmer, C. B.; Hilsenrath, E.; Mankin, W. G.; Murcray, D. G.; Pollitt, S.; Robbins, D. E.; Roscoe, H.

    Over the past few years, several field campaigns were devoted to the goal of assessing instrument reliability, as opposed to solely obtaining data to answer a geophysical question. Some examples of the formal instrument intercomparisons that have occurred in the past decade and those that are planned for the very near future are listed chronologically. Balloon-borne techniques and instruments that address the height profiles of the trace species in the lower stratosphere are emphasized. Beginning with the most extensively studied trace constituent, the approach taken and the results obtained, are described. The current status of the measurement capabilities are summarized, and the needs for future intercomparisons and assessments are listed.

  1. Hanford personnel dosimeter supporting studies FY-1981

    SciTech Connect

    Not Available

    1982-08-01

    This report examined specific functional components of the routine external personnel dosimeter program at Hanford. Components studied included: dosimeter readout; dosimeter calibration; dosimeter field response; dose calibration algorithm; dosimeter design; and TLD chip acceptance procedures. Additional information is also presented regarding the dosimeter response to light- and medium-filtered x-rays, high energy photons and neutrons. This study was conducted to clarify certain data obtained during the FY-1980 studies.

  2. PERSONNEL NEUTRON DOSIMETER

    DOEpatents

    Fitzgerald, J.J.; Detwiler, C.G. Jr.

    1960-05-24

    A description is given of a personnel neutron dosimeter capable of indicating the complete spectrum of the neutron dose received as well as the dose for each neutron energy range therein. The device consists of three sets of indium foils supported in an aluminum case. The first set consists of three foils of indium, the second set consists of a similar set of indium foils sandwiched between layers of cadmium, whereas the third set is similar to the second set but is sandwiched between layers of polyethylene. By analysis of all the foils the neutron spectrum and the total dose from neutrons of all energy levels can be ascertained.

  3. Pistol-shaped dosimeter charger

    DOEpatents

    Maples, R.A.

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  4. Pistol-shaped dosimeter charger

    DOEpatents

    Maples, Robert A.

    1985-01-01

    A pistol-shaped charger assembly clamps a cylindrical radiation dosimeter against one edge thereof. A triggerlike lever on the handgrip of the assembly is manually pivoted to actuate a piezoelectric current generator held in the handgrip and thereby charge the dosimeter.

  5. Piezoelectric dosimeter charger

    SciTech Connect

    Kronenberg, S.

    1981-01-27

    Disclosed is a small portable extremely rugged charger for existing pocket-sized type radiation dosimeters. The charger is comprised of a rectangularly shaped housing which contains a piezoelectric charging circuit which is manually operated by a handle to produce a relatively high charging voltage. The charging voltage is coupled to a charging post mounted on a removable cover which is adapted to be selectively rotated so that the underside of the charging post is exposed to light from one of two light windows in the housing whereupon the dosimeter scale may be viewed by either direct or reflected light from any source available. The piezoelectric charging circuit is comprised of a pair of axially aligned cylinders of piezoelectric material mounted in a fulcrum type frame having a beam lever element in contact with one of the cylinders. A spring bias element is connected to the beam lever element and is actuated by a cam attached to the handle which when rotated acts upon the spring to cause an axial compressional force to be applied to the cylinders which thereby produce the required charging voltage.

  6. Summary and analysis of neutron measurements conducted during the Oak Ridge personnel dosimetry intercomparison studies

    SciTech Connect

    Swaja, R.E.

    1987-01-01

    Since 1974, neutron personnel dosimetry intercomparison studies (PDIS) have been conducted annually at the Oak Ridge National Laboratory's (ORNL) Dosimetry Applications Research Facility. During these studies, neutron dosimeters are mailed to ORNL, exposed to low-level (less than 15 mSv) dose equivalents in a variety of mixed-radiation fields produced using the Health Physics Research Reactor (HPRR), and then returned to the participants for evaluation. Beginning with the Seventh PDIS in 1981, interest and participation in the Oak Ridge intercomparisons increased significantly and consistent and documented techniques for determining reference neutron dose equivalents for the HPRR were introduced. This document presents a summary and analysis of approximately 3400 neutron dose equivalent measurements made using a variety of personnel dosimeters and reported for PDIS 7-12. 16 refs., 3 tabs.

  7. Titan atmospheric models intercomparison

    NASA Astrophysics Data System (ADS)

    Pernot, P.

    2008-09-01

    Several groups over the world have developed independently models of the photochemistry of Titan. The Cassini mission reveals daily that the chemical complexity is beyond our expectations e. g. observation of heavy positive and negative ions..., and the models are updated accordingly. At this stage, there is no consensus on the various input parameters, and it becomes increasingly difficult to compare outputs form different models. An ISSI team of experts of those models will be gathered shortly to proceed to an intercomparison, i.e. to assess how the models behave, given identical sets of inputs (collectively defined). Expected discrepancies will have to be elucidated and reduced. This intercomparison will also be an occasion to estimate explicitly the importance of various physicalchemical processes on model predictions versus observations. More robust and validated models are expected from this study for the interpretation of Titanrelated data.

  8. Intercomparison of personal dosimetry for service providers in Pakistan.

    PubMed

    Jabeen, Akhter; Salman, Syed Ahmad

    2009-02-01

    An intercomparison exercise for personal dosimetry service providers within Pakistan was conducted by the Health Physics Division of the Pakistan Institute of Nuclear Science and Technology. Participation in the exercise was on voluntary basis. The exercise was carried out to harmonize individual dose monitoring techniques for high energy photons in terms of a new operational quantity, namely personal dose equivalent Hp(10), for personal dosimetry in accordance with the recommendations of the International Commission on Radiation Units and Measurements. Each laboratory submitted 25 dosimeters for participation in the intercomparison exercise. Protection level Co and Cs sources were used for irradiation of dosimeters on a water phantom according to International Atomic Energy Agency protocol at the Secondary Standard Dosimetry Laboratory. Hp(10) doses for five different dose levels were measured by the participating laboratories. The ratios of measured dose/true dose (Hm/Ht) remained in the range of 0.66 to 1.11 for the Co source and 0.84 to 1.17 for the Cs source. Performance of service providers' laboratories to measure Hp(10) doses was analyzed and evaluated in terms of trumpet curves plotted for photons at a 95% confidence level. PMID:19125056

  9. Thermoluminescence dosimeter reader

    SciTech Connect

    Miyake, S.; Miura, N.

    1984-10-30

    A thermoluminescence dosimeter reader having a heater for heating a thermoluminescence element, a light measuring circuit for measuring circuit for measuring the intensity of the thermoluminescence emanated from the element when it is heated and a display device for displaying the reading of the dosage of radiation to which the element is exposed according to the intensity of the thermoluminescence is provided with a dosage information inputting means which outputs an electric signal having a value representing a predetermined reference dosage of radiation, a calculating means for calculating a calibration constant which is the ratio between the value of the electric signal and the output value of the light measuring circuit which is the measured value of the dosage of radiation of a reference thermoluminescence element which is exposed to the predetermined reference dosage of radiation, and a memory means for memorizing the calibration constant.

  10. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, Roger B.; Tyree, William H.

    1984-12-18

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  11. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, R.B.; Tyree, W.H.

    1982-03-03

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  12. Miniature spectrally selective dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr. (Inventor)

    1980-01-01

    A miniature spectrally selective dosimeter capable of measuring selected bandwidths of radiation exposure on small mobile areas is described. This is achieved by the combination of photovoltaic detectors, electrochemical integrators (E-cells) and filters in a small compact case which can be easily attached in close proximity to and substantially parallel to the surface being measured. In one embodiment two photovoltaic detectors, two E-cells, and three filters are packaged in a small case with attaching means consisting of a safety pin. In another embodiment, two detectors, one E-cell, three filters are packaged in a small case with attaching means consisting of a clip to clip over a side piece of an eye glass frame.

  13. Quality audit of megavoltage radiotherapy units: intercomparison of dose at a reference point using a mailed TL-dosimetry system.

    PubMed

    Davis, B; Faessler, P

    1993-07-01

    A dosimetry intercomparison based on mailed TL-dosimeters and the well proven IAEA/EORTC phantom is described. Its aim is to identify discrepancies in dosimetry larger than +/- 3%. Dosimeters were mailed to all radiotherapy centres in Switzerland for irradiation with 2 Gy at a reference point in a water container, using photons and electrons. Thirty-six beams were monitored. The results show an agreement of within 2% for the majority of the beams monitored. Two electron beams were at 6% of the reference value. PMID:8234874

  14. Czech results at criticality dosimetry intercomparison 2002.

    PubMed

    Frantisek, Spurný; Jaroslav, Trousil

    2004-01-01

    Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV. PMID:15353690

  15. Brachytherapy dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F. C.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2015-07-01

    In-vivo and in-situ measurement of the radiation dose administered during brachytherapy faces several technical challenges, requiring a very compact, tissue-equivalent, linear and highly sensitive dosimeter, particularly in low-dose rate brachytherapy procedures, which use radioactive seeds with low energy and low dose deposition rate. In this work we present a scintillating optical fiber dosimeter composed of a flexible sensitive probe and a dedicated electronic readout system based on silicon photomultiplier photodetection, capable of operating both in pulse and current modes. The performance of the scintillating fiber optic dosimeter was evaluated in low energy regimes, using an X-ray tube operating at voltages of 40-50 kV and currents below 1 mA, to assess minimum dose response of the scintillating fiber. The dosimeter shows a linear response with dose and is capable of detecting mGy dose variations like an ionization chamber. Besides fulfilling all the requirements for a dosimeter in brachytherapy, the high sensitivity of this device makes it a suitable candidate for application in low-dose rate brachytherapy. According to Peralta and Rego [1], the BCF-10 and BCF-60 scintillating optical fibers used in dosimetry exhibit high variations in their sensitivity for photon beams in the 25-100 kVp energy range. Energy linearity for energies below 50 keV needs to be further investigated, using monochromatic X-ray photons.

  16. Passive dosimeters other than film and TLDs (thermoluminescent dosimeter)

    SciTech Connect

    Hankins, D.E.

    1986-05-15

    This presentation will describe CR-39 plastic as a personnel neutron dosimeter. Recent research at LLNL and elsewhere has resulted in the development of a dosimetry system that is superior to any personnel neutron dosimeter previously available. The author describes the features of the dosimetry system and the new etching procedures and techniques in detail. Most of the research was done at the LLNL and has been supported as a part of the DOE Neutron Dosimetry Upgrade Program. 10 refs., 4 figs., 1 tab.

  17. Dose-equivalent neutron dosimeter

    DOEpatents

    Griffith, R.V.; Hankins, D.E.; Tomasino, L.; Gomaa, M.A.M.

    1981-01-07

    A neutron dosimeter is disclosed which provides a single measurement indicating the amount of potential biological damage resulting from the neutron exposure of the wearer, for a wide range of neutron energies. The dosimeter includes a detecting sheet of track etch detecting material such as a carbonate plastic, for detecting higher energy neutrons, and a radiator layer contaning conversion material such as /sup 6/Li and /sup 10/B lying adjacent to the detecting sheet for converting moderate energy neutrons to alpha particles that produce tracks in the adjacent detecting sheet.

  18. INTERCOMPARISON OF PLUTONIUM-239 MEASUREMENTS

    EPA Science Inventory

    In 1977 the U.S. Environmental Protection Agency distributed calibrated solutions of plutonium-239 to laboratories interested in participating in an intercomparison study of plutonium analysis. Participants were asked to perform a quantitative radioactivity analysis of the soluti...

  19. Eleventh ORNL personnel dosimetry intercomparison study, May 22-23, 1985

    SciTech Connect

    Swaja, R.E.; Oyan, R.; Sims, C.S.

    1986-07-01

    The Eleventh Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory (ORNL) during May 22-23, 1985. Dosimeter badges from 44 participating organizations were mounted on Lucite block phantoms and exposed to four mixed-radiation fields with neutron dose equivalents around 5 mSv and gamma dose equivalents between 0.1 and 0.7 mSv. Results of this study indicated that no participants had difficulty obtaining measurable indication of neutron exposure at the provided dose equivalent levels, and very few had difficulty obtaining indication of gamma exposure at dose equivalents as low as 0.10 mSv. Average neutron results for all dosimeter types were within 20% of reference values with no obvious spectrum dependence. Different dosimeter types (albedo, direct interaction TLD, film, recoil track, and combination albedo-track) with 10 or more reported measurements provided average results within 35% of reference values for all spectra. With regard to precision, about 80% of the reported neutron results had single standard deviations within 10% at the means which indicates that precision is not a problem relative to accuracy for most participants. Average gamma results were greater than reference values by factors of 1.07 to 1.52 for the four exposures with TLD systems being more accurate than film. About 80% of all neutron results and 67% of all gamma results met regulatory standards for measurement accuracy and approximately 70% of all neutron data satisfied national dosimetry accreditation criteria for accuracy plus precision. In general, neutron dosimeter performance observed in this intercomparison was much improved compared to that observed in the prior studies while gamma dosimeter performance was about the same.

  20. Miniature personal UV solar dosimeter

    NASA Technical Reports Server (NTRS)

    Adams, R. R.; Macconochie, I. O.; Poole, B. D., Jr.

    1981-01-01

    Small light-powered meter measures accumulated radiation in ultraviolet or other selected regions. Practical advantages are device's low cost, small size, accuracy, and adaptability to specific wave-band measurements. Medical applications include detection of skin cancer, vitamin D production, and jaundice. Dosimeter also measures sunlight for solar energy designs, agriculture and meteorology, and monitors stability of materials and environmental and occupational lighting.

  1. Twelve years of neutron personnel dosimetry intercomparison studies at Oak Ridge National Laboratory: What have we learned

    SciTech Connect

    Swaja, R.E.

    1988-01-01

    To provide an opportunity for dosimetrists to test and calibrate their personnel neutron monitoring systems in a variety of incident radiation fields, the staff of the Dosimetry Applications Research (DOSAR) Facility at the Oak Ridge National Laboratory (ORNL) has conducted personnel dosimetry intercomparison studies (PDIS) periodically since 1974 and annually since 1976 (Si82, Sw87). During these studies, personnel dosimeters are mailed to ORNL, mounted on phantoms and exposed to low-level (less than 15 mSv) dose equivalents in mixed-radiation fields mainly produced using the Health Physics Research Reactor (HPRR) at ORNL (Au65), and then returned to the participants for evaluation. Reported dose equivalents are compared to reference values provided by the DOSAR staff and to results reported by individual organizations which made measurements under identical conditions. These intercomparisons, which require no fee and are open to any organization interested in external personnel dosimetry, have provided more data concerning neutron dosimeter performance characteristics in mixed-radiation fields than any other periodic open test program conducted to date. The following text presents a summary and analysis of neutron dose equivalent measurements reported for the seventh through twelfth intercomparisons (1981-1986) using the HPRR as the source of radiation. Particular factors examined include low dose equivalent sensitivity and measurement accuracy for the basic types of neutron personnel dosimeters. 5 refs., 1 fig.

  2. SOIL moisture data intercomparison

    NASA Astrophysics Data System (ADS)

    Kerr, Yann; Rodriguez-Frenandez, Nemesio; Al-Yaari, Amen; Parens, Marie; Molero, Beatriz; Mahmoodi, Ali; Mialon, Arnaud; Richaume, Philippe; Bindlish, Rajat; Mecklenburg, Susanne; Wigneron, Jean-Pierre

    2016-04-01

    The Soil Moisture and Ocean Salinity satellite (SMOS) was launched in November 2009 and started delivering data in January 2010. Subsequently, the satellite has been in operation for over 6 years while the retrieval algorithms from Level 1 to Level 2 underwent significant evolutions as knowledge improved. Other approaches for retrieval at Level 2 over land were also investigated while Level 3 and 4 were initiated. In this présentation these improvements are assessed by inter-comparisons of the current Level 2 (V620) against the previous version (V551) and new products either using neural networks or Level 3. In addition a global evaluation of different SMOS soil moisture (SM) products is performed comparing products with those of model simulations and other satellites (AMSR E/ AMSR2 and ASCAT). Finally, all products were evaluated against in situ measurements of soil moisture (SM). The study demonstrated that the V620 shows a significant improvement (including those at level1 improving level2)) with respect to the earlier version V551. Results also show that neural network based approaches can yield excellent results over areas where other products are poor. Finally, global comparison indicates that SMOS behaves very well when compared to other sensors/approaches and gives consistent results over all surfaces from very dry (African Sahel, Arizona), to wet (tropical rain forests). RFI (Radio Frequency Interference) is still an issue even though detection has been greatly improved while RFI sources in several areas of the world are significantly reduced. When compared to other satellite products, the analysis shows that SMOS achieves its expected goals and is globally consistent over different eco climate regions from low to high latitudes and throughout the seasons.

  3. RADIATION DOSIMETER AND DOSIMETRIC METHODS

    DOEpatents

    Taplin, G.V.

    1958-10-28

    The determination of ionizing radiation by means of single fluid phase chemical dosimeters of the colorimetric type is presented. A single fluid composition is used consisting of a chlorinated hydrocarbon, an acidimetric dye, a normalizer and water. Suitable chlorinated hydrocarbons are carbon tetrachloride, chloroform, trichloroethylene, trichlorethane, ethylene dichioride and tetracbloroethylene. Suitable acidimetric indicator dyes are phenol red, bromcresol purple, and creosol red. Suitable normallzers are resorcinol, geraniol, meta cresol, alpha -tocopberol, and alpha -naphthol.

  4. 1989 neutron and gamma personnel dosimetry intercomparison study using RADCAL (Radiation Calibration Laboratory) sources

    SciTech Connect

    Sims, C.S.; Casson, W.H.; Patterson, G.R. ); Murakami, H. . Dept. of Health Physics); Liu, J.C. )

    1990-10-01

    The fourteenth Personnel Dosimetry Intercomparison Study (i.e., PDIS 14) was conducted during May 1-5, 1989. A total of 48 organizations (33 from the US and 15 from abroad) participated in PDIS 14. Participants submitted by mail a total of 1,302 neutron and gamma dosimeters for this mixed field study. The type of neutron dosimeter and the percentage of participants submitting that type are as follows: TLD-albedo (40%), direct interaction TLD (22%), track (20%), film (7%), combination (7%), and bubble detectors (4%). The type of gamma dosimeter and the percentage of participants submitting that type are as follows: TLD (84%) and film (16%). Radiation sources used in the six PDIS 14 exposures included {sup 252}Cf moderated by 15-cm D{sub 2}O, {sup 252}Cf moderated by 15-cm polyethylene (gamma-enhanced with {sup 137}Cs), and {sup 238}PuBe. Neutron dose equivalents ranged from 0.44--2.63 mSv and gamma doses ranged from 0. 01-1.85 mSv. One {sup 252}Cf(D{sub 2}O) exposure was performed at a 60{degree} angle of incidence (most performance tests are at perpendicular incidence). The average neutron dosimeter response for this exposure was 70% of that at normal incidence. The average gamma dosimeter response was 96% of that at normal incidence. A total of 70% of individual reported neutron dosimeter measurements were within {plus minus}50% of reference values. If the 0.01 mSv data are omitted, approximately 90% of the individual reported gamma measurements were within {plus minus}50% of reference values. 33 refs., 9 figs., 27 tabs.

  5. Fast-neutron solid-state dosimeter

    DOEpatents

    Kecker, K.H.; Haywood, F.F.; Perdue, P.T.; Thorngate, J.H.

    1975-07-22

    This patent relates to an improved fast-neutron solid-state dosimeter that does not require separation of materials before it can be read out, that utilizes materials that do not melt or otherwise degrade at about 300$sup 0$C readout temperature, that provides a more efficient dosimeter, and that can be reused. The dosimeters are fabricated by intimately mixing a TL material, such as CaSO$sub 4$:Dy, with a powdered polyphenyl, such as p-sexiphenyl, and hot- pressing the mixture to form pellets, followed by out-gassing in a vacuum furnace at 150$sup 0$C prior to first use dosimeters. (auth)

  6. BETA-GAMMA PERSONNEL DOSIMETER

    DOEpatents

    Davis, D.M.; Gupton, E.D.; Hart, J.C.; Hull, A.P.

    1961-01-17

    A personnel dosimeter is offered which is sensitive to both gamma and soft beta radiations from all directions within a hemisphere. The device is in the shape of a small pill box which is worn on a worker-s wrist. The top and sides of the device are provided with 50 per cent void areas to give 50 per cent response to the beta rays and complete response to the gamma rays. The device is so constructed as to have a response which will approximate the dose received by the basal layer of the human epidermis.

  7. Portable neutron spectrometer and dosimeter

    DOEpatents

    Waechter, D.A.; Erkkila, B.H.; Vasilik, D.G.

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  8. Portable neutron spectrometer and dosimeter

    DOEpatents

    Waechter, David A.; Erkkila, Bruce H.; Vasilik, Dennis G.

    1985-01-01

    The disclosure relates to a battery operated neutron spectrometer/dosimeter utilizing a microprocessor, a built-in tissue equivalent LET neutron detector, and a 128-channel pulse height analyzer with integral liquid crystal display. The apparatus calculates doses and dose rates from neutrons incident on the detector and displays a spectrum of rad or rem as a function of keV per micron of equivalent tissue and also calculates and displays accumulated dose in millirads and millirem as well as neutron dose rates in millirads per hour and millirem per hour.

  9. Fourth Personnel Dosimetry Intercomparison Study

    SciTech Connect

    Dickson, H.W.

    1980-02-01

    The fourth Personnel Dosimetry Intercomparison Study was held at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during March 15-23, 1978. The Health Physics Research Reactor (HPRR) used unshielded, with a 12-cm-thick Lucite shield, a 20-cm-thick concrete shield, or a 5-cm-thick steel and 15-cm-thick concrete shield, and provided four neutron and gamma-ray spectra. Then the dose was calculated based on the HPRR neutron spectra and dose conversion factors which had been determined previously for the four spectra. The results of these personnel dosimetry intercomparison studies reveal that estimates of dose equivalent vary over a wide range. The standard deviation of the mean of participants data for gamma measurements was in the range of 29 to 43%; for neutrons it was 57 to 188%. (PCS)

  10. Dosimeter and method for using the same

    DOEpatents

    Warner, Benjamin P.; Johns, Deidre M.

    2003-06-24

    A very sensitive dosimeter that detects ionizing radiation is described. The dosimeter includes a breakable sealed container. A solution of a reducing agent is inside the container. The dosimeter has an air-tight dosimeter body with a transparent portion and an opaque portion. The transparent portion includes a transparent chamber that holds the breakable container with the reducing agent. The opaque portion includes an opaque chamber that holds an emulsion of silver salt (AgX) selected from silver chloride, silver bromide, silver iodide, and combinations of them. A passageway in the dosimeter provides fluid communication between the transparent chamber and the opaque chamber. The dosimeter may also include a chemical pH indicator in the breakable container that provides a detectable color change to the solution for a pH of about 3-10. The invention also includes a method of detecting ionizing radiation that involves producing the dosimeter, breaking the breakable container, allowing the solution to flow through the passageway and contact the emulsion, detecting any color change in the solution and using the color change to determine a radiation dosage.

  11. Radiation monitoring equipment dosimeter experiment

    NASA Astrophysics Data System (ADS)

    Hardy, Kenneth A.; Golightly, Michael J.; Quam, William

    Spacecraft crews risk exposure to relatively high levels of ionizing radiation. This radiation may come from charged particles trapped in the Earth's magnetic fields, charged particles released by solar flare activity, galactic cosmic radiation, energetic photons and neutrons generated by interaction of these primary radiations with spacecraft and crew, and man-made sources (e.g., nuclear power generators). As missions are directed to higher radiation level orbits, viz., higher altitudes and inclinations, longer durations, and increased flight frequency, radiation exposure could well become a major factor for crew stay time and career lengths. To more accurately define the radiological exposure and risk to the crew, real-time radiation monitoring instrumentation, which is capable of identifying and measuring the various radiation components, must be flown. This presentation describes a radiation dosimeter instrument which was successfully flown on the Space Shuttle, the RME-3.

  12. Radiation Monitoring Equipment Dosimeter Experiment

    NASA Technical Reports Server (NTRS)

    Hardy, Kenneth A.; Golightly, Michael J.; Quam, William

    1992-01-01

    Spacecraft crews risk exposure to relatively high levels of ionizing radiation. This radiation may come from charged particles trapped in the Earth's magnetic fields, charged particles released by solar flare activity, galactic cosmic radiation, energetic photons and neutrons generated by interaction of these primary radiations with spacecraft and crew, and man-made sources (e.g., nuclear power generators). As missions are directed to higher radiation level orbits, viz., higher altitudes and inclinations, longer durations, and increased flight frequency, radiation exposure could well become a major factor for crew stay time and career lengths. To more accurately define the radiological exposure and risk to the crew, real-time radiation monitoring instrumentation, which is capable of identifying and measuring the various radiation components, must be flown. This presentation describes a radiation dosimeter instrument which was successfully flown on the Space Shuttle, the RME-3.

  13. Comparative study of some new EPR dosimeters

    NASA Astrophysics Data System (ADS)

    Alzimami, K. S.; Maghraby, Ahmed M.; Bradley, D. A.

    2014-02-01

    Investigations have been made of four new radiation dosimetry EPR candidates from the same family of materials: sulfamic acid, sulfanillic acid, homotaurine, and taurine. Mass energy attenuation coefficients, mass stopping power values and the time dependence of the radiation induced radicals are compared. Also investigated are the microwave saturation behavior and the effect of applied modulation amplitude on both peak-to-peak line width (WPP) and peak-to-peak signal height (HPP). The dosimeters are characterized by simple spectra and stable radiation-induced radicals over reasonable durations, especially in taurine dosimeters. Sulfamic acid dosimeters possessed the highest sensitivity followed by taurine and homotaurine and sulfanillic.

  14. Fiber-type dosimeter with improved illuminator

    DOEpatents

    Fox, R.J.

    1985-12-23

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  15. Fiber-type dosimeter with improved illuminator

    DOEpatents

    Fox, Richard J.

    1987-01-01

    A single-piece, molded plastic, Cassigrainian-type condenser arrangement is incorporated in a tubular-shaped personal pocket dosimeter of the type which combines an ionization chamber with an optically-read fiber electrometer to provide improved illumination of the electrometer fiber. The condenser routes incoming light from one end of the dosimeter tubular housing around a central axis charging pin assembly and focuses the light at low angles to the axis so that it falls within the acceptance angle of the electrometer fiber objective lens viewed through an eyepiece lens disposed in the opposite end of the dosimeter. This results in improved fiber illumination and fiber image contrast.

  16. Summary and analsysis of the 1986 ORNL personnel dosimetry intercomparison study

    SciTech Connect

    Swaja, R.E.; Weng, P.S.; Sims, C.S.; Yeh, S.H.

    1987-04-01

    The Twelfth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory (ORNL) during April 14 to 17, 1986. Objectives of this study were to determine neutron dosimeter performance characteristics at neutron dose equivalent levels near the minimum specified for accreditation testing programs and to provide several radiation fields different from those that have been considered in prior ORNL intercomparisons. Dosimeter badges from 49 participating organizations were mounted on Lucite block phantoms and exposed to six mixed-radiation fields (five using the Health Physics Research Reactor and one using a PuBe source) with neutron dose equivalents of about 1.5 mSv and gamma dose equivalents between 0.04 and 5.37 mSv. Results of this study indicated that participants had no difficulty obtaining measurable indication of neutron exposure at dose equivalent levels of about 1.5 mSv. Average neutron results for all dosimeter types were within approximately 60% of reference values with hard spectra being more accurately measured than soft spectra. Considering all irradiations, albedo and direct interaction TLD systems provided about the same performance characteristics. With regard to precision, about 58% of the reported neutron results had single standard deviations within 10% at the means which indicates that precision was not a problem relative to accuracy for over half of the participants. Average gamma results varied from 0.98 to 2.22 times reference values for all exposures with TLD systems being more accurate than film. Some participants, especially those using film, had difficulty obtaining measurable indication of gamma exposures at dose equivalent levels lower than 0.09 mSv. About 69% of all neutron results and 77% of all gamma results met regulatory standards for measurement accuracy and approximately 65% of all neutron data satisfied national dosimetry accreditation criteria for accuracy plus precision. 18 refs., 1 fig., 30 tabs.

  17. Accident investigation

    NASA Technical Reports Server (NTRS)

    Laynor, William G. Bud

    1987-01-01

    The National Transportation Safety Board (NTSB) has attributed wind shear as a cause or contributing factor in 15 accidents involving transport-categroy airplanes since 1970. Nine of these were nonfatal; but the other six accounted for 440 lives. Five of the fatal accidents and seven of the nonfatal accidents involved encounters with convective downbursts or microbursts. Of other accidents, two which were nonfatal were encounters with a frontal system shear, and one which was fatal was the result of a terrain induced wind shear. These accidents are discussed with reference to helping the aircraft to avoid the wind shear or if impossible to help the pilot to get through the wind shear.

  18. Use of wrist albedo neutron dosimeters

    SciTech Connect

    Hankins, D.E.

    1983-01-01

    We are developing a wrist dosimeter that can be used to measure the exposure at the wrist to x-rays, gamma rays, beta-particles, thermal neutrons and fast neutrons. It consists of a modified Hankins Type albedo neutron dosimeter and also contains three pieces of CR-39 plastic. ABS plastic in the form of an elongated hemisphere provides the beta and low energy x-ray shielding necessary to meet the requirement of depth dose measurements at 1 cm. The dosimeter has a beta window located in the side of the hemisphere oriented towards an object being held in the hands. A TLD 600 is positioned under the 1 cm thick ABS plastic and is used to measure the thermal neutron dose. At present we are using Velcro straps to hold the dosimeter on the inside of the wrist. 9 figures.

  19. Polymer gel dosimeter based on itaconic acid.

    PubMed

    Mattea, Facundo; Chacón, David; Vedelago, José; Valente, Mauro; Strumia, Miriam C

    2015-11-01

    A new polymeric dosimeter based on itaconic acid and N, N'-methylenebisacrylamide was studied. The preparation method, compositions of monomer and crosslinking agent and the presence of oxygen in the dosimetric system were analyzed. The resulting materials were irradiated with an X-ray tube at 158cGy/min, 226cGymin and 298cGy/min with doses up to 1000Gy. The dosimeters presented a linear response in the dose range 75-1000Gy, sensitivities of 0.037 1/Gyat 298cGy/min and an increase in the sensitivity with lower dose rates. One of the most relevant outcomes in this study was obtaining different monomer to crosslinker inclusion in the formed gel for the dosimeters where oxygen was purged during the preparation method. This effect has not been reported in other typical dosimeters and could be attributed to the large differences in the reactivity among these species. PMID:26275817

  20. Performance criteria for dosimeter angular response

    SciTech Connect

    Roberson, P.L.; Fox, R. A.; Cummings, F. M.; McDonald, J. C.; Jones, K.L.

    1988-06-01

    This report provides criteria for evaluating the response of personnel dosimeters to radiation at nonperpendicular incidence. The US Department of Energy Laboratory Accreditation Program (DOELAP) ensures that dosimetry systems at DOE facilities meet acceptable standards for precision and accuracy. In the past, these standards were limited to tests for system variability, energy dependence, and level of detection. The proposed criteria will broaden the scope of DOELAP to include the angular response of personnel dosimeters. Because occupational exposures in the workplace are rarely due to radiation from only one direction, dosimeters must accurately assign individual dose equivalent from irradiation at any forward angle of incidence. Including an angular response criterion in DOELAP would improve the quality of personnel monitoring provided that the criterion is developed from appropriate dose quantities. This report provides guidance for assigning individual dose equivalents for radiation fields at nonperpendicular incidence to the dosimeter. 21 refs., 10 figs., 10 tabs.

  1. Intercomparison of Retrospective Radon Detectors

    SciTech Connect

    Field, R W.; Steck, D J.; Parkhurst, Maryann ); Mahaffey, Judith A. ); Alavanja, M C.

    1998-11-01

    We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, (2) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass implanted polonium activities, and (3) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted Po-210 activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type.

  2. The LLNL CR-39 personnel neutron dosimeter

    SciTech Connect

    Hankins, D.E.; Homann, S.; Westermark, J.

    1987-09-29

    We developed a personnel neutron dosimetry system based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This CR-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. 3 refs., 4 figs.

  3. Models and Measurements Intercomparison 2

    NASA Technical Reports Server (NTRS)

    Park, Jae H. (Editor); Ko, Malcolm K. W. (Editor); Jackman, Charles H. (Editor); Plumb, R. Alan (Editor); Kaye, Jack A. (Editor); Sage, Karen H. (Editor)

    1999-01-01

    Models and Measurement Intercomparison II (MM II) summarizes the intercomparison of results from model simulations and observations of stratospheric species. Representatives from twenty-three modeling groups using twenty-nine models participated in these MM II exercises between 1996 and 1999. Twelve of the models were two- dimensional zonal-mean models while seventeen were three-dimensional models. This was an international effort as seven were from outside the United States. Six transport experiments and five chemistry experiments were designed for various models. Models participating in the transport experiments performed simulations of chemically inert tracers providing diagnostics for transport. The chemistry experiments involved simulating the distributions of chemically active trace cases including ozone. The model run conditions for dynamics and chemistry were prescribed in order to minimize the factors that caused differences in the models. The report includes a critical review of the results by the participants and a discussion of the causes of differences between modeled and measured results as well as between results from different models, A sizable effort went into preparation of the database of the observations. This included a new climatology for ozone. The report should help in evaluating the results from various predictive models for assessing humankind perturbations of the stratosphere.

  4. Intercomparison of retrospective radon detectors.

    PubMed Central

    Field, R W; Steck, D J; Parkhurst, M A; Mahaffey, J A; Alavanja, M C

    1999-01-01

    We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha-emission of a (210)Pb-decay product, (210)Po. The detector's track density generation rate (tracks per square centimeter per hour) is proportional to the surface alpha-activity. In the absence of other strong sources of alpha-emission in the glass, the implanted surface alpha-activity should be proportional to the accumulated (210)Po, and hence to the cumulative radon gas exposure. The goals of the intercomparison were to a) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, b) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass-implanted polonium activities, and c) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted (210)Po activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type

  5. Dose mapping of the rectal wall during brachytherapy with an array of scintillation dosimeters

    SciTech Connect

    Cartwright, L. E.; Suchowerska, N.; Yin, Y.; Lambert, J.; Haque, M.; McKenzie, D. R.

    2010-05-15

    Purpose: In pelvic brachytherapy treatments, the rectum is an organ at risk. The authors have developed an array of scintillation dosimeters suitable for in vivo use that enables quality assurance of the treatment delivery and provides an alert to potential radiation accidents. Ultimately, this will provide evidence to direct treatment planning and dose escalation and correlate dose with the rectal response. Methods: An array of 16 scintillation dosimeters in an insertable applicator has been developed. The dosimeters were calibrated simultaneously in a custom designed circular jig before use. Each dosimeter is optically interfaced to a set of pixels on a CCD camera located outside the treatment bunker. A customized software converts pixel values into dose rate and accumulates dose for presentation during treatment delivery. The performance of the array is tested by simulating brachytherapy treatments in a water phantom. The treatment plans were designed to deliver a known dose distribution on the surface of the rectal applicator, assumed to represent the dose to the rectal wall. Results: The measured doses were compared to those predicted by the treatment plan and found to be in agreement to within the uncertainty in measurement, usually within 3%. The array was also used to track the progression of the source as it moved along the catheter. The measured position was found to agree with the position reported by the afterloader to within the measurement uncertainty, usually within 2 mm. Conclusions: This array is capable of measuring the actual dose received by each region of the rectal wall during brachytherapy treatments. It will provide real time monitoring of treatment delivery and raise an alert to a potential radiation accident. Real time dose mapping in the clinical environment will give the clinician additional confidence to carry out dose escalation to the tumor volume while avoiding rectal side effects.

  6. INTERLABORATORY INTERCOMPARISON OF POLONIUM-210 MEASUREMENTS

    EPA Science Inventory

    In 1975 the U.S. Environmental Protection Agency distributed calibrated solutions of polonium-210 to laboratories interested in participating in an intercomparison study of polonium-210 analysis. Participants were asked to perform a quantitative radioactivity analysis of the solu...

  7. Results from the Second International Module Intercomparison

    SciTech Connect

    Rummel, S.; Anderberg, A.; Emery, K.

    2005-11-01

    The peak-watt rating is a primary indicator of PV performance. The peak power rating is the maximum electrical power that is produced when the PV device is continuously illuminated at 1000 Wm/sup-2/ total irradiance under International Electrotechnical Commission Standard 60904-2 reference spectrum, and 25 deg C cell temperature. Most manufacturers trace their peak-watt rating through calibrations performed at recognized terrestrial calibration facilities. Manufacturers typically perform intercomparisons among a set of their modules internally with other plants and among. Sometimes they have the same module measured at different calibration facilities to determine the differences in calibration. This intercomparison was to mimic this procedure and supply new thin film samples along with samples that could pose other problems. These intercomparisons sample the laboratories' everyday procedures better than a formal intercomparison where the laboratories' best procedures and data scrutiny are used.

  8. Environmental dosimeter of the thermoluminescent type

    DOEpatents

    Eichner, F.N.; Kocher, L.F.

    1974-01-29

    A dosimeter for accurately monitoring normally low-energy radiation including a thermoluminescent CaF phosphor enclosed within a tantalum capsule is described. The tantalum acts as a filter to weaken the measured dose due to photons having energies below about 0.2 MeV. Tantalum end caps are maintained on the capsule body by a polyolefin sheath formed from heat-contractable tubing. After exposing the dosimeter to environmental radiation, it is placed in a shielded chamber for about 24 h and subsequently annealed at about 80 deg C to release radiation energy accumulated in low-temperature traps. The dosimeter is then disassembled and the phosphors photometrically read at temperatures about 50 deg C to determine the absorbed radiation dose. (Official Gazette)

  9. System for use with solid state dosimeter

    DOEpatents

    Miller, S.D.; McDonald, J.C.; Eichner, F.N.; Tomeraasen, P.L.

    1990-09-04

    The present invention constitutes a system for determining the amounts of ionizing radiation to which dosimeters using thermoluminescent materials have been exposed. In accordance with this system, the thermoluminescent materials which comprise the dosimeters are first cooled by contact with a cryogenic substance such as liquefied nitrogen. The thermoluminescent materials are then optically stimulated by exposure to ultraviolet light. Thereafter, the amounts of visible light emitted by the thermoluminescent materials are detected and counted as the materials are allowed to warm up to room temperature. The amounts of luminescence exhibited by the materials are related to radiation exposure and provide a sensitive measure of radiation dosage. It has been discovered that the above procedure is most effective when heavily doped thermoluminescent materials are used and that the procedure allows many useful plastic materials to now be employed in dosimeter constructions. 3 figs.

  10. System for use with solid state dosimeter

    DOEpatents

    Miller, Steven D.; McDonald, Joseph C.; Eichner, Fred N.; Tomeraasen, Paul L.

    1990-01-01

    The present invention constitutes a system for determining the amounts of ionizing radiation to which dosimeters using thermoluminescent materials have been exposed. In accordance with this system, the thermoluminescent materials which comprise the dosimeters are first cooled by contact with a cryogenic substance such as liquified nitrogen. The thermoluminescent materials are then optically stimulated by exposure to ultraviolet light. Thereafter, the amounts of visible light emitted by the thermoluminescent materials are detected and counted as the materials are allowed to warm up to room temperature. The amounts of luminescence exhibited by the materials are related to radiation exposure and provide a sensitive measure of radiation dosage. It has been discovered that the above procedure is most effective when heavily doped thermoluminescent materials are used and that the procedure allows many useful plastic materials to now be employed in dosimeter constructions.

  11. Do saccharide doped PAGAT dosimeters increase accuracy?

    NASA Astrophysics Data System (ADS)

    Berndt, B.; Skyt, P. S.; Holloway, L.; Hill, R.; Sankar, A.; De Deene, Y.

    2015-01-01

    To improve the dosimetric accuracy of normoxic polyacrylamide gelatin (PAGAT) gel dosimeters, the addition of saccharides (glucose and sucrose) has been suggested. An increase in R2-response sensitivity upon irradiation will result in smaller uncertainties in the derived dose if all other uncertainties are conserved. However, temperature variations during the magnetic resonance scanning of polymer gels result in one of the highest contributions to dosimetric uncertainties. The purpose of this project was to study the dose sensitivity against the temperature sensitivity. The overall dose uncertainty of PAGAT gel dosimeters with different concentrations of saccharides (0, 10 and 20%) was investigated. For high concentrations of glucose or sucrose, a clear improvement of the dose sensitivity was observed. For doses up to 6 Gy, the overall dose uncertainty was reduced up to 0.3 Gy for all saccharide loaded gels compared to PAGAT gel. Higher concentrations of glucose and sucrose deteriorate the accuracy of PAGAT dosimeters for doses above 9 Gy.

  12. Solid state neutron dosimeter for space applications

    SciTech Connect

    Nagarkar, V.; Entine, G.; Stoppel, P.; Cirignano, L. ); Swinehart, P. )

    1992-08-01

    One of the most important contributions to the radiation exposure of astronauts engaged in space flight is the significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Under NASA sponsorship, the authors are developing a solid state neutron sensor capable of being incorporated into a very compact, flight instrument to provide high quality real time measurement of this important radiation flux. The dosimeter uses a special, high neutron sensitivity, PIN diode that is insensitive t the other forms of ionizing radiation. The dosimeter will have the ability to measure and record neutron dose over a range of 50 microgray to tens of milligrays (5 millirads to several rads) over a flight of up to 30 days. the performance characteristics of the PIN diode with a detailed description of the overall dosimeter is presented. in this paper.

  13. Blue irradiance intercomparison in the medical field

    NASA Astrophysics Data System (ADS)

    Ferreira, Antonio F. G.

    2012-10-01

    This work presents the results of a blue irradiance intercomparison among industrial laboratories of medical devices companies. This intercomparison aims to support the metrological issues of medical equipment manufactures regarding the blue irradiance infant phototherapy equipment requirements on the international standard IEC 60601-2-50:2000. The results showed a low agreement of participants' measurements according to normalized error criterion. The major explanation for this result is associated to an incorrect equipment choice and long recalibration period.

  14. Automating the personnel dosimeter monitoring program

    SciTech Connect

    Compston, M.W.

    1982-12-01

    The personnel dosimetry monitoring program at the Portsmouth uranium enrichment facility has been improved by using thermoluminescent dosimetry to monitor for ionizing radiation exposure, and by automating most of the operations and all of the associated information handling. A thermoluminescent dosimeter (TLD) card, worn by personnel inside security badges, stores the energy of ionizing radiation. The dosimeters are changed-out periodically and are loaded 150 cards at a time into an automated reader-processor. The resulting data is recorded and filed into a useful form by computer programming developed for this purpose.

  15. Fiber optic dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2014-08-01

    A small dimension, real-time readout dosimeter is desirable for specific applications in medical physics as for example, dose measurement in prostate brachytherapy. This particular radiotherapy procedure consists in the permanent deposition of low energy, low-dose and low-dose rate small sized radioactive seeds. We developed a scintillating fiber optic based dosimeter suitable for in-vivo, real-time low dose and low dose rate measurements. Due to the low scintillation light produced in the scintillating fiber, a high sensitive and high gain light detector is required. The Silicon Photomultipliers are an interesting option that allowed us to obtain good results in our studies.

  16. Intercomparison of dosimetry measurements at the alternating gradient synchrotron from 1986-1988.

    PubMed

    Musolino, S; Rohrig, N; Baker, T

    1993-07-01

    The responses of several types of high-energy personnel neutron dosimeters were studied in the operational radiation fields at the Alternating Gradient Synchrotron. Included in the study are intercomparisons of polycarbonate, type A neutron track emulsion, allyl diglycol carbonate, electrochemical etch allyl diglycol carbonate, TLD-600, and TLD-700. Some of the passive measurements were compared with active tissue-equivalent instruments. The trend for many but not all of the measurements was for type A neutron track emulsion to report the highest neutron dose equivalent. The polycarbonate returned intermediate values while allyl diglycol carbonate usually reported the smallest values. Quality assurance data from calibration sources through 1990 are also provided. PMID:8505236

  17. A new type of extremity dosimeter

    NASA Astrophysics Data System (ADS)

    Uchrin, György

    1980-09-01

    A three element sandwich type dosimeter has been developed. The beta element is LiF cold pressed to an Al disc the response of which follows the energy dependence of the true skin beta dose for Emax⩾ 0.2 MeV. Filtered LiF hot pressed chips measure gamma dose and indicate the radiation quality.

  18. Response characteristics of selected personnel neutron dosimeters

    SciTech Connect

    McDonald, J.C.; Fix, J.J.; Hadley, R.T.; Holbrook, K.L.; Yoder, R.C.; Roberson, P.L.; Endres, G.W.R.; Nichols, L.L.; Schwartz, R.B.

    1983-09-01

    Performance characteristics of selected personnel neutron dosimeters in current use at Department of Energy (DOE) facilities were determined from their evaluation of neutron dose equivalent received after irradiations with specific neutron sources at either the National Bureau of Standards (NBS) or the Pacific Northwest Laboratory (PNL). The characteristics assessed included: lower detection level, energy response, precision and accuracy. It was found that when all of the laboratories employed a common set of calibrations, the overall accuracy was approximately +-20%, which is within uncertainty expected for these dosimeters. For doses above 80 mrem, the accuracy improved to better than 10% when a common calibration was used. Individual differences found in this study may reflect differences in calibration technique rather than differences in the dose rates of actual calibration standards. Second, at dose rates above 100 mrem, the precision for the best participants was generally below +-10% which is also within expected limits for these types of dosimeters. The poorest results had a standard deviation of about +-25%. At the lowest doses, which were sometimes below the lower detection limit, the precision often approached or exceeded +-100%. Third, the lower level of detection for free field /sup 252/Cf neutrons generally ranged between 20 and 50 mrem. Fourth, the energy dependence study provided a characterization of the response of the dosimeters to neutron energies far from the calibration energy. 11 references, 22 figures, 26 tables.

  19. Investigating hydrogel dosimeter decomposition by chemical methods

    NASA Astrophysics Data System (ADS)

    Jordan, Kevin

    2015-01-01

    The chemical oxidative decomposition of leucocrystal violet micelle hydrogel dosimeters was investigated using the reaction of ferrous ions with hydrogen peroxide or sodium bicarbonate with hydrogen peroxide. The second reaction is more effective at dye decomposition in gelatin hydrogels. Additional chemical analysis is required to determine the decomposition products.

  20. Pen Ink as an Ultraviolet Dosimeter

    ERIC Educational Resources Information Center

    Downs, Nathan; Turner, Joanna; Parisi, Alfio; Spence, Jenny

    2008-01-01

    A technique for using highlighter ink as an ultraviolet dosimeter has been developed for use by secondary school students. The technique requires the students to measure the percentage of colour fading in ink drawn onto strips of paper that have been exposed to sunlight, which can be calibrated to measurements of the ultraviolet irradiance using…

  1. Compton effect thermally activated depolarization dosimeter

    DOEpatents

    Moran, Paul R.

    1978-01-01

    A dosimetry technique for high-energy gamma radiation or X-radiation employs the Compton effect in conjunction with radiation-induced thermally activated depolarization phenomena. A dielectric material is disposed between two electrodes which are electrically short circuited to produce a dosimeter which is then exposed to the gamma or X radiation. The gamma or X-radiation impinging on the dosimeter interacts with the dielectric material directly or with the metal composing the electrode to produce Compton electrons which are emitted preferentially in the direction in which the radiation was traveling. A portion of these electrons becomes trapped in the dielectric material, consequently inducing a stable electrical polarization in the dielectric material. Subsequent heating of the exposed dosimeter to the point of onset of ionic conductivity with the electrodes still shorted through an ammeter causes the dielectric material to depolarize, and the depolarization signal so emitted can be measured and is proportional to the dose of radiation received by the dosimeter.

  2. Nuclear accident dosimetry studies at Los Alamos National Laboratory

    SciTech Connect

    Casson, W.H.; Buhl, T.E.; Upp, D.L.

    1995-12-01

    Two critical assemblies have been characterized at the Los Alamos Critical Experiments Facility (LACEF) for use in testing nuclear accident dosimeters and related devices. These device, Godiva IV and SHEBA II, have very different characteristics in both operation and emitted neutron energy spectra. The Godiva assembly is a bare metal fast burst device with a hard spectrum. This spectrum can be modified by use of several shields including steel, concrete, and plexiglas. The modified spectra vary in both average neutron energy and in the specific distribution of the neutron energies in the intermediate energy range. This makes for a very favorable test arrangement as the response ratios between different activation foils used in accident dosimeters are significantly altered such as the ratio between gold, copper, and sulfur elements. The SHEBA device is a solution assembly which has both a slow ramp and decay period and a much softer spectrum. The uncertainly introduced in the response of fast decay foils such as indium can therefore be evaluated into the test results. The neutron energy spectrum for each configuration was measured during low power operations with a multisphere system. These measurements were extended to high dose pulsed operation by use of TLDs moderated TLDs, and special activation techniques. The assemblies were used in the testing of several accident dosimetry devices in studies modeled after the Nuclear Accident Dosimetry Studies that were conducted at Oak Ridge National Laboratory for about 25 years using the Health Physics Research Reactor. It is our intention to conduct these studies approximately annually for the evaluation of the nuclear accident dosimeter systems currently in use within the DOE, alternative systems used internationally, and new dosimeter designs being developed or considered for field application. Participation in selected studies will be open to all participants.

  3. EURADOS intercomparison on emergency radiobioassay.

    PubMed

    Li, Chunsheng; Battisti, Paolo; Berard, Philippe; Cazoulat, Alain; Cuellar, Antonio; Cruz-Suarez, Rodolfo; Dai, Xiongxin; Giardina, Isabella; Hammond, Derek; Hernandez, Carolina; Kiser, Stephen; Ko, Raymond; Kramer-Tremblay, Sheila; Lecompte, Yannick; Navarro, Eva; Navas, Cristina; Sadi, Baki; Sierra, Inmaculada; Verrezen, Freddy; Lopez, Maria A

    2015-12-01

    Nine laboratories participated in an intercomparison exercise organised by the European Radiation Dosimetry Group (EURADOS) for emergency radiobioassay involving four high-risk radionuclides ((239)Pu, (241)Am, (90)Sr and (226)Ra). Diverse methods of analysis were used by the participating laboratories for the in vitro determination of each of the four radionuclides in urine samples. Almost all the methods used are sensitive enough to meet the requirements for emergency radiobioassay derived for this project in reference to the Clinical Decision Guide introduced by the NCRP. Results from most of the methods meet the requirements of ISO 28218 on accuracy in terms of relative bias and relative precision. However, some technical gaps have been identified. For example, some laboratories do not have the ability to assay samples containing (226)Ra, and sample turnaround time would be expected to be much shorter than that reported by many laboratories, as timely results for internal contamination and early decisions on medical intervention are highly desired. Participating laboratories are expected to learn from each other on the methods used to improve the interoperability among these laboratories. PMID:25543132

  4. Panasonic dosimetry system performance testing and results at nuclear accident dose levels 500 rad to 10,000 rad

    SciTech Connect

    Klueber, M.R.

    1998-04-06

    Panasonic thermoluminescent dosimeters (TLDs) are used as the photon dose assessment part of the personal nuclear accident dosimeter (PNAD) and may be used for the same purpose with the fixed nuclear accident dosimeter (FNAD). To demonstrate compliance with 10CFR835.1304 (and, its predecessor, DOE Order 5480.11), several sets of dosimeters were irradiated to photon doses above the upper limit of the DOELAP testing standard, DOE/EH-0026 and DOE/EH-0027. The upper range of the test was 10,000 rads, using both low energy (70 keV) and high energy (662 keV and 1,332 keV) sources. The testing indicated that the Panasonic TLD system is capable of meeting the requirements of 10CFR835.1304 and DOE Order 5480.11.

  5. INTERCOMPARISON OF OPTICAL REMOTE SENSING SYSTEMS FOR ROADSIDE MEASUREMENTS

    EPA Science Inventory

    The presentation describes results of an intercomparison of three optical remote sensing systems for measurements of nitric oxide emitted from passenger cars and light-duty trucks. The intercomparison included a standards comparison to establish comparability of standards, follo...

  6. Intercomparison of luminescence detectors for space radiation dosimetry within Proton-ICCHIBAN experiments

    NASA Astrophysics Data System (ADS)

    Uchihori, Yukio; Ploc, Ondrej; Yasuda, Nakahiro; Berger, Thomas; Hajek, Michael; Kodaira, Satoshi; Benton, Eric; Ambrozova, Iva; Kitamura, Hisashi

    2012-07-01

    Luminescence detectors for space radiation dosimetry are frequently used to estimate personal and environmental doses in the International Space Station and other space vehicles. Detector responses for cosmic rays and their secondaries were investigated for a long time and it is well-known that luminescence detectors have dependencies of response on LET (Linear Energy Transfer). Some of luminescence detectors show over-response to gamma rays (used for routine calibration) and others have similar responses to gamma rays. But, because of lack of sufficient and reliable calibration data in the low LET region (about 1 keV/μm), it is the responses of these detectors at LET is poorly known. Protons make up the dominant portion of the fluence from space radiation, so the LET region corresponding to energetic protons must be characterized very well. For that purpose, calibration and intercomparison experiments were performed using relatively low energy (30 to 80 MeV) proton beams at the National Institute of Radiological Sciences, Chiba, Japan. In this paper, the results of these intercomparison experiments, including high energy protons and light ions, are reported and illustrate the response of luminescence detectors in the low LET region. This research will help improve our understanding of space dosimeters and reliable dose measurement for astronauts and cosmonauts in low earth orbit.

  7. An intercomparison of nitric oxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, J. M., Jr.; Gregory, G. L.; Mcdougal, D. S.; Carroll, M. A.; Mcfarland, M.; Ridley, B. A.; Davis, D. D.; Bradshaw, J.; Rodgers, M. O.; Torres, A. L.

    1985-01-01

    Results from an intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted at Wallops Island, VA, in July 1983. Instruments intercompared included a laser-induced fluorescence system and two chemiluminescence instruments. The intercomparisons were performed with ambient air at NO mixing ratios ranging from 10 to 60 pptv and NO-enriched ambient air at mixing ratios from 20 to 170 pptv. All instruments sampled from a common manifold. The techniques exhibited a high degree of correlation among themselves and with changes in the NO mixing ratio. Agreement among the three techniques was placed at approximately + or - 30 percent. Within this level of agreement, no artifacts or species interferences were identified.

  8. Intercomparison of atmospheric dispersion models

    NASA Astrophysics Data System (ADS)

    Caputo, Marcelo; Giménez, Marcelo; Schlamp, Miguel

    An intercomparison between Gaussian, Gaussian segmented plumes and Lagrangian codes is presented. The codes chosen for the simulation of a gaseous emission under real meteorological conditions were AERMOD, HPDM, PCCOSYMA and HYSPLIT. The emission source was located at 37.35°N and 78.24°W in a flat terrain. The meteorological data were obtained from RAMS code output. The AERMOD and HPDM meteorological preprocessors results were analyzed. The main differences found are originated in the sensible heat flux (SHTF) and u* (friction velocity) computation, whose values impact directly on the Monin-Obukov length and mixing height calculation. These differences and the strong dependence of the results on them indicate that more development should still be done in order to improve the algorithms for the meteorological variables calculations, mainly during stable conditions. A more realistic description is performed by the segmented Gaussian plume model (PCCOSYMA) respect to the Gaussian ones (AERMOD, HPDM) because it limits the plume length along the wind direction. It also predicts reasonably well the contaminant cloud rotation respect to the Lagrangian code (HYSPLIT) as no major difference between the wind field and the wind at the source location is present in the analyzed case. During the stable hours, HPDM calculates the most stable situation and the lowest mixing heights. Because of this there is a considerable discrepancy in the maximum ground level concentration respect to the other codes. While during the unstable hours HPDM calculates the most unstable situation, nevertheless the maximum ground level concentrations predicted by all the Gaussian and Lagrangian codes are comparable.

  9. Desert Dust Satellite Retrieval Intercomparison

    NASA Technical Reports Server (NTRS)

    Carboni, E.; Thomas, G. E.; Sayer, A. M.; Siddans, R.; Poulsen, C. A.; Grainger, R. G.; Ahn, C.; Antoine, D.; Bevan, S.; Braak, R.; Brindley, H.; DeSouza-Mchado, S.; Deuze, J. L.; Diner, D.; Ducos, F.; Grey, W.; Hsu, C.; Kalashnikova, O. V.; Kahn, R.; North, P. R. J.; Salustro, C.; Smith, A.; Tanre, D.; Torres, O.; Veihelmann, B.

    2012-01-01

    This work provides a comparison of satellite retrievals of Saharan desert dust aerosol optical depth (AOD) during a strong dust event through March 2006. In this event, a large dust plume was transported over desert, vegetated, and ocean surfaces. The aim is to identify and understand the differences between current algorithms, and hence improve future retrieval algorithms. The satellite instruments considered are AATSR, AIRS, MERIS, MISR, MODIS, OMI, POLDER, and SEVIRI. An interesting aspect is that the different algorithms make use of different instrument characteristics to obtain retrievals over bright surfaces. These include multi-angle approaches (MISR, AATSR), polarisation measurements (POLDER), single-view approaches using solar wavelengths (OMI, MODIS), and the thermal infrared spectral region (SEVIRI, AIRS). Differences between instruments, together with the comparison of different retrieval algorithms applied to measurements from the same instrument, provide a unique insight into the performance and characteristics of the various techniques employed. As well as the intercomparison between different satellite products, the AODs have also been compared to co-located AERONET data. Despite the fact that the agreement between satellite and AERONET AODs is reasonably good for all of the datasets, there are significant differences between them when compared to each other, especially over land. These differences are partially due to differences in the algorithms, such as as20 sumptions about aerosol model and surface properties. However, in this comparison of spatially and temporally averaged data, at least as significant as these differences are sampling issues related to the actual footprint of each instrument on the heterogeneous aerosol field, cloud identification and the quality control flags of each dataset.

  10. The Development, Characterization, and Performance Evaluation of a New Combination Type Personnel Neutron Dosimeter

    NASA Astrophysics Data System (ADS)

    Liu, Chwei-Jeng

    A new combination type personnel neutron dosimeter has been designed and developed at the Oak Ridge National Laboratory (ORNL). The combination personnel neutron dosimeter (CPND) consists of a Harshaw albedo neutron thermoluminescent dosimeter (two pairs of TLD-600/TLD-700) and two bubble detectors (one BD-100R and one BDS-1500 from Bubble Technology Industries, Canada). The CPND was developed with the aim of having crude neutron spectrometric capability, universal applicability, better angular response, and an improved lower limit of detection (LLD). The CPND has been well characterized in the following areas: reusability, linearity, lower limit of detection (LLD), detection capability in mixed neutron-gamma fields, angular dependence, and neutron energy dependence. The characterization was accomplished with irradiations using a ^{238} Pu-Be source, a ^{252} Cf(D_2O) source, a ^{252}Cf source, a ^ {252}Cf(PE) source, monoenergetic neutrons from accelerator and reactor filtered beams, ^ {137}Cs, and X-rays. Optimum signal readout procedures, signal processing techniques, routine operational usage, and neutron dose equivalent evaluation algorithms for the CPND were developed with the goals of having the best precision and accuracy as well as being convenient to use. Various reference spectra were developed to evaluate the performance (mainly the spectrometric and the dose equivalent measurement capabilities) of the CPND. The performance of the CPND was evaluated by in-situ tests in radiation fields existing in the working environment at ORNL. The spectra in these areas were measured previously with a calibrated Bonner multisphere spectrometer. The CPND also was tested with laboratory radioisotopic sources in single-source and multi-source exposure situations. Finally, the CPND was tested by participating in the fourteenth Personnel Dosimetry Intercomparison Study. The results of the tests mentioned above demonstrated that the CPND meets the ambitious design purposes

  11. An intercomparison of airborne nitric acid measurements

    NASA Astrophysics Data System (ADS)

    Gregory, G. L.; Hoell, J. M.; Huebert, B. J.; van Bramer, S. E.; Lebel, P. J.; Vay, S. A.; Marinaro, R. M.; Schiff, H. I.; Hastie, D. R.; Mackay, G. I.; Karecki, D. R.

    1990-06-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of nitric acid are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted during the summer of 1986. Instruments intercompared included a denuder tube collection system (DENUDER) with chemiluminescent detection, a niylon filter collection system (FILTER) with ion chromatography detection, and a tunable diode laser (TDLAS) multipath absorption system. Intercomparison of investigators' calibration standards were also performed as part of the test protocol. While results were somewhat "soft" and data sparse, these tests suggested that the TDLAS measurements might be high compared to the other techniques. Airborne intercomparisons were conducted predominately in the free troposphere and included encounters with marine and continental air masses. While the intercomparisons included mixing ratios to 1000 parts per trillion by volume (pptv), the majority of the results were for mixing ratios of <300 pptv. The TDLAS participated in an intercomparison of NO2 instruments (major focus) that was also conducted during the same flights. As a result the TDLAS data set is limited. Further, a significant fraction of the nitric acid measurements were below the TDLAS detection limit (75 pptv as configured for these tests). While the lack of simultaneous measurements from the three instruments limits the conclusions that can be drawn, it is clear that there can be substantial disagreement among the three techniques, even at mixing ratios above their respective detection limits. Equally clear is that at mixing ratios below 150 pptv there is very little correlation between their results. Based on these observations, an overall conclusion from the intercomparison is that none of the HNO3 techniques can be identified to unambiguously (e.g., 20% accuracy) provide measurements of HNO3 at levels often encountered in the

  12. Clinical applications of 3-D dosimeters

    NASA Astrophysics Data System (ADS)

    Wuu, Cheng-Shie

    2015-01-01

    Both 3-D gels and radiochromic plastic dosimeters, in conjunction with dose image readout systems (MRI or optical-CT), have been employed to measure 3-D dose distributions in many clinical applications. The 3-D dose maps obtained from these systems can provide a useful tool for clinical dose verification for complex treatment techniques such as IMRT, SRS/SBRT, brachytherapy, and proton beam therapy. These complex treatments present high dose gradient regions in the boundaries between the target and surrounding critical organs. Dose accuracy in these areas can be critical, and may affect treatment outcome. In this review, applications of 3-D gels and PRESAGE dosimeter are reviewed and evaluated in terms of their performance in providing information on clinical dose verification as well as commissioning of various treatment modalities. Future interests and clinical needs on studies of 3-D dosimetry are also discussed.

  13. Radiological properties of normoxic polymer gel dosimeters

    SciTech Connect

    Venning, A.J.; Nitschke, K.N.; Keall, P.J.; Baldock, C.

    2005-04-01

    The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m{sup -3}) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.

  14. Performance evaluation of a colorimetric hydrazine dosimeter

    NASA Astrophysics Data System (ADS)

    Brenner, Karen P.; Rose-Pehrsson, Susan L.

    1994-06-01

    A dosimeter for real-time, colorimetric detection of hydrazine in air has been developed. The passive badge consists of a dosimeter card containing a vanillin solution coated on a thin paper substrate. The active patch consists of a thick cellulose substrate coated with a vanillin solution. When placed in a plastic sample holder attached to a personnel pump, up to 5 L/min can be drawn through the active badge substrate. Through a condensation reaction, vanillin reacts with hydrazine to form a colored product that absorbs in the visible region. The hydrazone formed in the reaction is yellow; its intensity is proportional to the dose. When exposed passively to hydrazine, the experimental detection limit is less than 20 ppb-hrs. Extrapolated results indicate a detection limit of less than 5 ppb-hrs for long sampling periods. Actively sampling of hydrazine vapors gives an experimental detection limit of less than 100 ppb-L at a sample rate of 5 L/min. Relative humidity effects on badge response were minor. High humidity enhanced the color development on the vanillin badge; while low humidity had no effect on badge response. Interference testing of the dosimeters revealed a tobacco smoke interference. Preliminary shelf life tests indicated no decrease in sensitivity to hydrazine when stored at room temperature for 6 months.

  15. Indoor and Outdoor Spectroradiometer Intercomparison for Spectral Irradiance Measurement

    SciTech Connect

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, R.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-05-01

    This report details the global spectral irradiance intercomparison using spectroradiometers that was organized by the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. The intercomparison was performed both indoors and outdoors on September 17, 2013. Five laboratories participated in the intercomparison using 10 spectroradiometers, and a coordinated measurement setup and a common platform were employed to compare spectral irradiances under both indoor and outdoor conditions. The intercomparison aimed to understand the performance of the different spectroradiometers and to share knowledge in making spectral irradiance measurements. This intercomparison was the first of its kind in the United States.

  16. Use of two dosimeters for better estimation of effective dose

    NASA Astrophysics Data System (ADS)

    Kim, Chan-Hyeong

    Obviously, a single dosimeter on the chest can underestimate effective dose (E) and effective dose equivalent (HE) significantly when radiation comes from the back because the dosimeter on the chest is shielded by the body of a radiation worker. This problem can be solved by using an extra dosimeter on the back so that at least one dosimeter is always directly exposed to radiation. In this work, the use of two dosimeters was studied using the MCNP code and mathematical phantoms. First, an optimal combination of dosimeter weighting factors was found to be 0.58 and 0.42 for chest and back dosimeters, respectively, through a systematic optimization process. The optimal algorithm, which uses these weighting factors, was superior to other algorithms reported in the literature. The underestimation problem when using a single-dosimeter approach for posterior incident radiation was completely solved by using two dosimeters and the optimal algorithm. The two-dosimeter approach also estimated E and HE very well for a broad range of frontal incident photon beams, neither underestimating E or HE by more than 11%, nor overestimating by more than about 50%. Although the use of two dosimeters effectively solved the underestimation problem of the single-dosimeter approach for posterior incident radiation, this approach overestimated E and HE for lateral, overhead, and underfoot beam directions. However, this overestimation can be reduced by using suitably selected anisotropic-responding dosimeters. To study the effect of anisotropic-responding properties of personal dosimeters on the estimation of E and HE, this work considered several types of anisotropic-responding dosimeters. In practical exposure situations, radiation workers move during exposure, which results in less overestimation of E and HE than static lateral, overhead, and underfoot exposures. To quantify the reduction of the overestimation by the movement of radiation workers, we averaged photon beam results over

  17. Role of gel dosimeters in boron neutron capture therapy.

    PubMed

    Khajeali, Azim; Farajollahi, Ali Reza; Khodadadi, Roghayeh; Kasesaz, Yaser; Khalili, Assef

    2015-09-01

    Gel dosimeters have acquired a unique status in radiotherapy, especially with the advent of the new techniques in which there is a need for three-dimensional dose measurement with high spatial resolution. One of the techniques in which the use of gel dosimeters has drawn the attention of the researchers is the boron neutron capture therapy. Exploring the history of gel dosimeters, this paper sets out to study their role in the boron neutron capture therapy dosimetric process. PMID:26070173

  18. Hanford beta-gamma personnel dosimeter prototypes and evaluation

    SciTech Connect

    Fix, J.J.; Holbrook, K.L.; Soldat, K.L.

    1983-04-01

    Upgraded and modified Hanford dosimeter prototypes were evaluated for possible use at Hanford as a primary beta-gamma dosimeter. All prototypes were compatible with the current dosimeter card and holder design, as well as processing with the automated Hanford readers. Shallow- and deep-dose response was determined for selected prototypes using several beta sources, K-fluorescent x rays and filtered x-ray techniques. All prototypes included a neutron sensitive chip. A progressive evaluation of the performance of each of the upgrades to the current dosimeter is described. In general, the performance of the current dosimeter can be upgraded using individual chip sensitivity factors to improve precision and an improved algorithm to minimize bias. The performance of this dosimeter would be adequate to pass all categories of the ANSI N13.11 performance criteria for dosimeter procesors, provided calibration techniques compatible with irradiations adopted in the standard were conducted. The existing neutron capability of the dosimeter could be retained. Better dosimeter performance to beta-gamma radiation can be achieved by modifying the Hanford dosimeter so that four of the five chip positions are devoted to calculating these doses instead of the currently used two chip positions. A neutron sensitive chip was used in the 5th chip position, but all modified dosimeter prototypes would be incapable of discriminating between thermal and epithermal neutrons. An improved low energy beta response can be achieved for the current dosimeter and all prototypes considered by eliminating the security credential. Further improvement can be obtained by incorporating the 15-mil thick TLD-700 chips.

  19. SPARC Reanalysis Intercomparison Project (S-RIP)

    NASA Astrophysics Data System (ADS)

    Fujiwara, M.; Long, C. S.

    2014-12-01

    The middle atmosphere and climate community use reanalyses widely to understand atmospheric processes and variability in the middle atmosphere, to validate climate models, and, potentially, for trend analysis. Yet different reanalyses give different results for the same diagnostic. There is thus a need for a coordinated reanalysis intercomparison project that shall start a comprehensive activity to compare all appropriate reanalysis data sets for key diagnostics to help understand the causes of differences and to use the results to provide guidance on appropriate usage of various reanalysis products in scientific studies. In addition, the reanalysis community will benefit from coordinated user feedback, which can lead to improvements in the next generation of reanalysis products. The Stratosphere-troposphere Processes And their Role in Climate (SPARC) Reanalysis Intercomparison Project (S-RIP) is a SPARC activity that was proposed in 2012 and approved in 2014. The goals of S-RIP are: (1) to create a communication platform between the SPARC community and the reanalysis centers; (2) to understand current reanalysis products and to contribute to future reanalysis improvements in the middle atmosphere region; and (3) to write up the results of the reanalysis intercomparison in peer reviewed papers and a SPARC report. The project duration is from 2013 to 2018. In the presentation, an overview of the project is made and some early intercomparison results are discussed.

  20. Comparison of the fiber optic dosimeter and semiconductor dosimeter for use in diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Yoo, W. J.; Shin, S. H.; Sim, H. I.; Hong, S.; Kim, S. G.; Jang, J. S.; Kim, J. S.; Jeon, H. S.; Kwon, G. W.; Jang, K. W.; Cho, S.; Lee, B.

    2014-05-01

    A fiber-optic dosimeter (FOD) was fabricated using a plstic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure entrance surface dose (ESD) in diagnostic radiology. Under changing tube current and irradition time of the digital radiography (DR) system, we measured the scintillating light and the ESD simultaneously. As experiemtnal results, the total counts of the FOD were changed in a manner similar to the ESDs of the semiconductor dosimeter (SCD). In conclusion, we demonstrated that the proposed FOD minimally affected the diagnostic information of DR image while the SCD caused serious image artifacts.

  1. GAMMA AND X-RAY DOSIMETER AND DOSIMETRIC METHOD

    DOEpatents

    Taplin, G.V.; Douglas, C.H.; Sigoloff, S.C.

    1958-08-19

    An improvement in colorimetric gamma and x-ray dosimeter systems and a self-contained. hand carried dostmeter of the afore-mentioned type ts described. A novel point of the invention ltes in the addition of specific quantities of certain normalizing agents to the two phase chlorinated hydro-carbon-aqueous dyc colortmetric dosimeter to eliminate the after reaction and thereby extend the utility of such systein. The structure of the two phase colorimetric dosimeter tubes and the carrying case for the tubes of the portable dosimeter are unique features.

  2. Evaluation of discrepancies between thermoluminescent dosimeter and direct-reading dosimeter results

    SciTech Connect

    Shaw, K.R.

    1993-07-01

    Currently at Oak Ridge National Laboratory (ORNL), the responses of thermoluminescent dosimeters (TLDs) and direct-reading dosimeters (DRDs) are not officially compared or the discrepancies investigated. However, both may soon be required due to the new US Department of Energy (DOE) Radiological Control Manual. In the past, unofficial comparisons of the two dosimeters have led to discrepancies of up to 200%. This work was conducted to determine the reasons behind such discrepancies. For tests conducted with the TLDs, the reported dose was most often lower than the delivered dose, while DRDs most often responded higher than the delivered dose. Trends were identified in personnel DRD readings, and ft was concluded that more training and more control of the DRDs could improve their response. TLD responses have already begun to be improved; a new background subtraction method was implemented in April 1993, and a new dose algorithm is being considered. It was concluded that the DOE Radiological Control Manual requirements are reasonable for identifying discrepancies between dosimeter types, and more stringent administrative limits might even be considered.

  3. Real-time optical fiber dosimeter probe

    NASA Astrophysics Data System (ADS)

    Croteau, André; Caron, Serge; Rink, Alexandra; Jaffray, David; Mermut, Ozzy

    2011-03-01

    There is a pressing need for a passive optical fiber dosimeter probe for use in real-time monitoring of radiation dose delivered to clinical radiation therapy patients. An optical fiber probe using radiochromic material has been designed and fabricated based on a thin film of the radiochromic material on a dielectric mirror. Measurements of the net optical density vs. time before, during, and after irradiation at a rate of 500cGy/minute to a total dose of 5 Gy were performed. Net optical densities increased from 0.2 to 2.0 for radiochromic thin film thicknesses of 2 to 20 μm, respectively.

  4. Evaluation of a Colorimetric Personal Dosimeter for Nitrogen Oxide.

    ERIC Educational Resources Information Center

    Diamond, Philip

    A personal colorimetric dosimeter for nitrogen dioxide was developed. Tests were performed to determine the response of these strips to various concentrations of NO2. The dosimeter strips were satisfactory for approximate determinations of total exposure (concentration + time) of nitrogen dioxide. The total exposure was calculated in terms of time…

  5. A remote fiber optic dosimeter network for detecting hydrazine vapor

    SciTech Connect

    Klimcak, C.; Radhakrishnan, G.; Jaduszliwer, B.

    1995-12-31

    A fiber optic chemical dosimeter has been developed for use in the remote detection of vapors of toxic amine rocket fuels (hydrazine and its substituted derivatives) that are used as Air Force and civilian launch sites. The dosimeter employs a colorimetric indicating reagent immobilized in a porous sol-gel cladding on multimode fiber. This reagent reacts selectively with the fuel vapor to produce a strongly absorbing cladding that introduces light propagation losses in the fiber; these losses indicate the presence of hydrazine (N{sub 2}H{sub 4}) vapor. The absorption occurs over a broad spectral range ideally suited for interrogation by semiconductor diode lasers. The authors have shown that the dosimeter yields an average hydrazine detectivity of 2.3 exposures of the dosimeter to laboratory air have not adversely affected the dosimeter. Additionally, its response to ammonia vapor has been determined to be 9,200 times smaller than its response to hydrazine vapor.

  6. Numerical simulation of `DMSP` dosimeter response

    SciTech Connect

    Jordan, T.M. ||

    1993-12-31

    Four Defense Meteorological Satellite Program (DMSP) dosimeters were modeled for numerical simulation of radiation response. The modeling included the hemispherical aluminum dome, the solid state detector, and the tungsten base plate. Orbits were generated for 840 km and 98 degrees inclination and used with 1965 and 1985 magnetic field models and the AP8 and AE8 data sets to obtain solar minimum and solar maximum integral fluences for protons and electrons. Adjoint Monte Carlo methods were then used to simulate the transport of these environments in the geometric models of the dosimeters. Volume average dose calculations were used to calculate the response of the LOLET (less than 1 MeV deposited per particle) channels to electrons and secondary bremsstrahlung. Monte Carlo methods were used, in conjunction with a pulse height analysis, to obtain the proton response of the LOLET and HILET (1 to 10 MeV deposited per particle) channels. The HILET and LOLET responses obtained from these calculations are in good agreement with DMSP measurements for 1984-85.

  7. A scintillating fiber dosimeter for radiotherapy

    NASA Astrophysics Data System (ADS)

    Bartesaghi, G.; Conti, V.; Bolognini, D.; Grigioni, S.; Mascagna, V.; Prest, M.; Scazzi, S.; Mozzanica, A.; Cappelletti, P.; Frigerio, M.; Gelosa, S.; Monti, A.; Ostinelli, A.; Giannini, G.; Vallazza, E.

    2007-10-01

    Radiotherapy, together with chemotherapy and surgery, is one of the main methods applied in the fight against cancer; in order to increase the chances of a successful radiotherapy treatment the dose delivery to the tumor and the surrounding normal tissues has to be computed with high accuracy. Traditional dosimeters are accurate but single channel (ionization chambers and diodes) or non real-time (radiographic films) devices. At present there is no device water equivalent that can perform real-time and bidimensional measurements of a dose distribution. This article describes the development of a real-time dosimeter based on scintillating fibers for photon and electron beams; the fibers are made of polystyrene, that is water equivalent and thus tissue equivalent, allowing a direct dose calculation. Three prototypes (single and multichannel) have been assembled, consisting in small scintillators coupled to white fibers that carry the light to photomultiplier tubes. In this article the prototypes and the readout electronics are described, together with the results of the measurements with electron and photon beams with energy up to 20 MeV (produced by linear accelerators Varian Clinac 1800 and 2100CD).

  8. An intercomparison of airborne nitric acid measurements

    SciTech Connect

    Gregory, G.L.; Hoell, J.M. Jr.; LeBel, P.J.; Vay, S.A. ); Huebert, B.J. ); Van Bramer, S.E. ); Marinaro, R.M. ); Schiff, H.I.; Hastie, D.R. ); Mackay, G.I.; Karecki, D.R. )

    1990-06-20

    Instruments intercompared included a denuder tube collection system (DENUDER) with chemiluminescent detection, a nylon filter collection system (FILTER) with ion chromatography detection, and a tunable diode laser (TDLAS) multipath absorption system. While results were somewhat soft and data sparse, these tests suggested that the TDLAS measurements might be high compared to the other techniques. Airborne intercomparisons were conducted predominantly in the free troposphere and included encounters with marine and continental air masses. While the intercomparisons included mixing ratios to 1,000 parts per trillion by volume (pptv), the majority of the results were for mixing ratios of <300 pptv. While the lack of simultaneous measurements from the three instruments limits the conclusions that can be drawn, it is clear that there can be substantial disagreement among the three techniques, even at mixing ratios above their respective detection limits. Equally clear is that at mixing ratios below 150 pptv there is very little correlation between their results. Based on these observations, an overall conclusion from the intercomparison is that none of the HNO{sub 3} techniques can be identified to unambiguously (e.g., 20% accuracy) provide measurements of HNO{sub 3} at levels often encountered in the free troposphere (e.g., 100 pptv). However, at the more elevated levels of HNO{sub 3} (e.g., >150 pptv), both the FILTER and DENUDER techniques reported the same levels of nitric acid, while as suggested by the results from the standards intercomparison, the TDLAS reported higher nitric acid values than the other two techniques.

  9. Radiation accidents.

    PubMed

    Saenger, E L

    1986-09-01

    It is essential that emergency physicians understand ways to manage patients contaminated by radioactive materials and/or exposed to external radiation sources. Contamination accidents require careful surveys to identify the metabolic pathway of the radionuclides to guide prognosis and treatment. The level of treatment required will depend on careful surveys and meticulous decontamination. There is no specific therapy for the acute radiation syndrome. Prophylactic antibodies are desirable. For severely exposed patients treatment is similar to the supportive care given to patients undergoing organ transplantation. For high-dose extremity injury, no methods have been developed to reverse the fibrosing endarteritis that eventually leads to tissue death so frequently found with this type of injury. Although the Three Mile Island episode of March 1979 created tremendous public concern, there were no radiation injuries. The contamination outside the reactor building and the release of radioiodine were negligible. The accidental fuel element meltdown at Chernobyl, USSR, resulted in many cases of acute radiation syndrome. More than 100,000 people were exposed to high levels of radioactive fallout. The general principles outlined here are applicable to accidents of that degree of severity. PMID:3526994

  10. Radiation accidents

    SciTech Connect

    Saenger, E.L.

    1986-09-01

    It is essential that emergency physicians understand ways to manage patients contaminated by radioactive materials and/or exposed to external radiation sources. Contamination accidents require careful surveys to identify the metabolic pathway of the radionuclides to guide prognosis and treatment. The level of treatment required will depend on careful surveys and meticulous decontamination. There is no specific therapy for the acute radiation syndrome. Prophylactic antibodies are desirable. For severely exposed patients treatment is similar to the supportive care given to patients undergoing organ transplantation. For high-dose extremity injury, no methods have been developed to reverse the fibrosing endarteritis that eventually leads to tissue death so frequently found with this type of injury. Although the Three Mile Island episode of March 1979 created tremendous public concern, there were no radiation injuries. The contamination outside the reactor building and the release of radioiodine were negligible. The accidental fuel element meltdown at Chernobyl, USSR, resulted in many cases of acute radiation syndrome. More than 100,000 people were exposed to high levels of radioactive fallout. The general principles outlined here are applicable to accidents of that degree of severity.

  11. Inter-comparison of subglacial hydrological models

    NASA Astrophysics Data System (ADS)

    de Fleurian, Basile; Werder, Mauro

    2016-04-01

    The recent emergence of a number of subglacial hydrological models allows us to obtain theoretical insights on basal processes; for instance on the coupling between water pressure and the sliding of glaciers. In ice-flow models, it is relatively clear what the simulated physics ought to be. Conversely, the physical processes incorporated into subglacial hydrology models are diverse as it is yet unclear which ones are of relevance for a particular setting. An inter-comparison of hydrology models will therefore need a somewhat different approach to the one used in the many ice-flow model inter-comparisons (EISMINT, ISMIP, etc.). Here, we present a set of experiments that will allow the comparison of the behavior of different hydrology models. The design of the benchmark aims at allowing the participation of a wide range of models based on different physical approaches. We aim at evaluating the models with a focus on the effective pressure which has the most impact on the dynamics of glaciers. The aim of this inter-comparison is to provide modellers with the necessary data to make an informed decision on which subglacial hydrology model to use for a particular study.

  12. The 1991 WMO ozone sonde intercomparison

    NASA Technical Reports Server (NTRS)

    Kerr, James B.; Mcelroy, C. Thomas; Fast, Hans; Oltmans, Sam J.; Lathrop, Jeff A.; Kyro, Esko; Paukkunen, Ari; Claude, Hans J.; Kohler, Ulf; Sreedharan, C. R.

    1994-01-01

    The WMO ozone sonde intercomparison was held at Vanscoy, Saskatchewan from May 13 to May 24, 1991. The purpose of the intercomparison is to evaluate the performance of various ozone sonde types used operationally in the Global Ozone Observing System and to ensure that the accuracy and precision of the measurements are sufficient to detect long-term trends in stratospheric ozone. The intercomparison was sponsored by WMO and hosted by the Atmospheric Environment Service (AES) of Canada. It was attended by scientists from six countries: Canada, Finland, Germany, India, Japan and USA. A total of 10 balloon payloads were launched each carrying 7 or 8 sondes for a total of 67 successful ozone sonde flights. The payloads were carried to altitudes between 35 and 40 km where the flights terminated by balloon burst. Results of the profile measurements made during the series of the profile measurements made during the series of flight are used to determine statistically meaningful evaluations of the different sonde types. A description of the payload and the different ozone sondes is given. Preliminary results of the profile measurements and an evaluation of the performance of the sonde types are presented.

  13. Dose evaluation in criticality accidents using response of Panasonic TL personal dosemeters (UD-809/UD-802).

    PubMed

    Zeyrek, C T; Gündüz, H

    2012-09-01

    This study gives the results of dosimetry measurements carried out in the Silène reactor at Valduc (France) with neutron and photon personal thermoluminescence dosemeters (TLDs) in mixed neutron and gamma radiation fields, in the frame of the international accident dosimetry intercomparison programme in 2002. The intercomparison consisted of a series of three irradiation scenarios. The scenarios took place at the Valduc site (France) by using the Silène experimental reactor. For neutron and photon dosimetry, Panasonic model UD-809 and UD-802 personal TLDs were used together. PMID:22389154

  14. A Method of Determining Accuracy and Precision for Dosimeter Systems Using Accreditation Data

    SciTech Connect

    Rick Cummings and John Flood

    2010-12-01

    A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively.

  15. A method of determining accuracy and precision for dosimeter systems using accreditation data.

    PubMed

    Cummings, Frederick; Flood, John R

    2010-12-01

    A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively. PMID:21068596

  16. Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison

    SciTech Connect

    Harrison, K. M.; Ebert, M. A.; Kron, T.; Howlett, S. J.; Cornes, D.; Hamilton, C. S.; Denham, J. W.

    2011-10-15

    Purpose: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. Methods: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. Results: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a ''patient'' to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. Conclusions: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.

  17. SU-E-T-265: Presage Thin Sheet Dosimeter Characterization

    SciTech Connect

    Dumas, M; Rakowski, J

    2014-06-01

    Purpose: To quantify the sensitivity and stability of the Presage dosimeter in sheet form for different concentrations of chemicals and for a diverse range of clinical photon energies. Methods: Presage polymer dosimeters are formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green reporting dye, and bromoform radical initiator in 1mm thick sheets. The chemicals are well mixed together, cast in an aluminum mold, and left to cure at 60 psi for a minimum of 2 days. Dosimeter response will be characterized at multiple energies including Co-60, 6 MV, 15 MV, 50 kVp, and 250 kVp. The dosimeters are read by an Epson 10000 XL scanner at 800 dpi, 2{sup 16} bit depth. Red component images are analyzed with ImageJ. Results: Analysis of optical density verse dose for Co-60 energies indicates that the bromoform containing Presage was able to quantify dose from 0 to 300 Gy, with saturation beyond 300 Gy. Initial results show two regions of linear response, 0–100 Gy and 150–300 Gy. The 150–300 Gy region has a sensitivity of 0.0024 net OD/Gy. Further results on other energies are still in progress. Conclusions: This work shows the potential for use of thin sheets of Presage dosimeter as a dosimeter capable of being analyzed with a flatbed scanner.

  18. Limitations of using dosimeters in impulse noise environments.

    PubMed

    Kardous, Chucri A; Willson, Robert D

    2004-07-01

    The National Institute for Occupational Safety and Health (NIOSH) investigated the capabilities of noise dosimeters to measure personal exposure to impulse noise. The two leading types of commercially available dosimeters were evaluated in terms of their ability to measure and integrate impulses generated from gunfire during live-fire exercises at a law enforcement indoor firing range. Sound measurements were conducted throughout the firing range using dosimeters, sound level meters, and a measurement configuration that consisted of a quarter-inch microphone and a digital audiotape recorder to capture the impulse waveforms. Personal dosimetry was conducted on eight shooters, an observer, and the range master. Peak levels from gunfire reached 163 decibels (dB), exceeding the nominal input limit of the dosimeters. The dosimeters "clipped" the impulses by acting as if the gunfire had a maximum level of 146 dB. In other cases, however, peak levels (e.g., 108 dB) were below the dosimeter input limits, but the dosimeters still showed a peak level of 146 dB. Although NIOSH recommends that sound levels from 80 to 140 dB (A-weighted) be integrated in the calculation of dose and the time-weighted average, our present data suggest this criterion may be inadequate. These results showed that some instruments are incapable of providing accurate measures of impulse sounds because of their electroacoustic limitations. PMID:15238316

  19. Radiation Measured during ISS-Expedition 13 with Different Dosimeters

    NASA Technical Reports Server (NTRS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Lee, K.; George, T.

    2008-01-01

    Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

  20. Calibration system for albedo neutron dosimeters

    SciTech Connect

    Rothermich, N.E.

    1981-01-01

    Albedo neutron dosimeters have proven to be effective as a method of measuring the dose from neutron exposures that other types of neutron detectors cannot measure. Results of research conducted to calibrate an albedo neutron dosemeter are presented. The calibration procedure consisted of exposing the TLD chips to a 46 curie /sup 238/PuBe source at known distances, dose rates and exposure periods. The response of the TLD's is related to the dose rate measured with a dose rate meter to obtain the calibration factor. This calibration factor is then related to the ratio of the counting rates determined by 9-inch and 3-inch Bonner spheres (also called remmeters) and a calibration curve was determined. 17 references, 10 figures, 3 tables.

  1. p-MOSFET total dose dosimeter

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  2. A miniature MOSFET radiation dosimeter probe.

    PubMed

    Gladstone, D J; Lu, X Q; Humm, J L; Bowman, H F; Chin, L M

    1994-11-01

    Prototype miniature dosimeter probes have been designed, built, and characterized employing a small, radiation sensitive metal oxide semiconductor field effect transistor (MOSFET) chip to measure, in vivo, the total accumulated dose and dose rate as a function of time after internal administration of long range beta particle radiolabeled antibodies and in external high energy photon and electron beams. The MOSFET detector is mounted on a long narrow alumina substrate to facilitate electrical connection. The MOSFET, alumina substrate, and lead wires are inserted into a 16 gauge flexineedle, which, in turn, may be inserted into tissue. The radiation dosimeter probe has overall dimensions of 1.6 mm diam and 3.5 cm length. The MOSFET probe signals are read, stored, and analyzed using an automated data collection and analysis system. Initially, we have characterized the probe's response to long range beta particle emission from 90Y sources in solution and to high energy photon and electron beams from linear accelerators. Since the prototype has a finite substrate thickness, the angular dependence has been studied using beta particle emission from a 90Sr source. Temperature dependence and signal drift have been characterized and may be corrected for. Measurements made in spherical volumes containing 90Y with diameters less than the maximum electron range, to simulate anticipated geometries in animal models, agree well with Berger point kernel and EGS4 Monte Carlo calculations. The results from the prototype probes lead to design requirements for detection of shorter range beta particles used in radioimmunotherapy and lower photon energies used in brachytherapy. PMID:7891632

  3. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, Tuan

    1987-01-01

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique.

  4. Dosimeter for monitoring vapors and aerosols of organic compounds

    DOEpatents

    Vo-Dinh, T.

    1987-07-14

    A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

  5. A new dosimeter formulation for deformable 3D dose verification

    NASA Astrophysics Data System (ADS)

    Høye, E. M.; Skyt, P. S.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Balling, P.

    2015-01-01

    We present the characteristics of a new silicone-based radiochromic dosimeter containing the leuco-malachite green (LMG) dye. The dose response as well as the dose-rate and photon-energy dependence of the dosimeter were characterized. To optimise the dose response, different concentrations of the chemical components were investigated. The dose response was found to decrease exponentially as a function of time after irradiation. A cylindrical dosimeter was produced and irradiated with a volumetric modulated arc therapy plan; the standard deviation between measured and calculated dose was 5% of the total dose.

  6. Investigation of thermoluminescence properties of mobile phone screen displays as dosimeters for accidental dosimetry

    NASA Astrophysics Data System (ADS)

    Mrozik, Anna; Marczewska, B.; Bilski, P.; Kłosowski, M.

    2014-11-01

    The rapid assessment of the radiation dose after unexpected exposure is a task of accidental dosimetry. In case of a radiological accident glasses originating from mobile phone screens, placed usually near the human body, could be used as emergency thermoluminescent (TL) personal dosimeters. The time between irradiation and TL readout is crucial and therefore preparation of the mobile phone screens and their readout conditions should be optimized. The influence of the samples etching, bleaching and selection of the optical filters based on measurement of the emission spectrum of irradiated glass samples during heating for different types of mobile phones were the subjects of our investigation. Obtained results showed that glasses extracted from different brands of mobile phones have different dosimetric properties but all of them give a luminescent signal which can be used to calculate the dose.

  7. Personal noise dosimeters: accuracy and reliability in varied settings.

    PubMed

    Cook-Cunningham, Sheri Lynn

    2014-01-01

    This study investigated the accuracy, reliability, and characteristics of three brands of personal noise dosimeters (N = 7 units) in both pink noise (PN) environments and natural environments (NEs) through the acquisition of decibel readings, Leq readings and noise doses. Acquisition periods included repeated PN conditions, choir room rehearsals and participant (N = 3) Leq and noise dosages procured during a day in the life of a music student. Among primary results: (a) All dosimeters exhibited very strong positive correlations for PN measurements across all instruments; (b) all dosimeters were within the recommended American National Standard Institute (ANSI) SI.25-1991 standard of ±2 dB (A) of a reference measurement; and (c) all dosimeters were within the recommended ANSI SI.25-1991 standard of ±2 dB (A) when compared with each other. Results were discussed in terms of using personal noise dosimeters within hearing conservation and research contexts and recommendations for future research. Personal noise dosimeters were studied within the contexts of PN environments and NEs (choral classroom and the day in the life of collegiate music students). This quantitative study was a non-experimental correlation design. Three brands of personal noise dosimeters (Cirrus doseBadge, Quest Edge Eg5 and Etymotic ER200D) were tested in two environments, a PN setting and a natural setting. There were two conditions within each environment. In the PN environment condition one, each dosimeter was tested individually in comparison with two reference measuring devices (Ivie and Easera) while PN was generated by a Whites Instrument PN Tube. In condition two, the PN procedures were replicated for longer periods while all dosimeters measured the sound levels simultaneously. In the NE condition one, all dosimeters were placed side by side on a music stand and recorded sound levels of choir rehearsals over a 7-h rehearsal period. In NE, condition two noise levels were measured during

  8. A US intercomparison of Josephson array voltage standards

    SciTech Connect

    Rodriguez, K.M.; Huntley, L.

    1994-12-31

    Qualification of intrinsic standards is a problem for laboratory accreditation systems. Accredited laboratories must demonstrate that their intrinsic standards actually provide the accuracy claimed. Ten standards laboratories have participated in an intercomparison of their 10 Volt Josephson Array Standards. The intercomparison program is described and results are presented.

  9. DOE Radiological Calibrations Intercomparison Program: Results of fiscal year 1987

    SciTech Connect

    Cummings, F.M.; McDonald, J.C.

    1988-06-01

    This report presents the FY 1987 results of the radiological calibrations intercomparison program. The intercomparison operation is discussed, and the equipment is described, particularly the instrument set, the beta source set, and relevant calculations. Solutions to problems and improvements in the program are suggested, and conclusions are then introduced. 9 refs., 3 figs., 8 tabs.

  10. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  11. Stratospheric Ozone Intercomparison Campaign (STOIC) 1989: Overview

    NASA Technical Reports Server (NTRS)

    Margitan, J. J.; Barnes, R. A.; Brothers, G. B.; Butler, J.; Burris, J.; Connor, B. J.; Ferrare, R. A.; Kerr, J. B.; Komhyr, W. D.; McCormick, M. P.; McDermid, I. S.; McElroy, C. T.; McGee, T. J.; Miller, A. J.; Owens, M.; Parrish, A. D.; Parsons, C. L.; Torres, A. L.; Tsou, J. J.; Walsh, T. D.

    1995-01-01

    The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE 2) aboard the Earth Radiation Budget Satellite and the Total Ozone Mapping Spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the

  12. Method and apparatus for reading free falling dosimeter punchcodes

    DOEpatents

    Langsted, J.M.

    1992-12-22

    A punchcode reader is provided for reading data encoded in a punchcode hole array on a dosimeter. The dosimeter falls through a passage in the reader containing photosensor detectors disposed along the passage which provide output signals to a microprocessor. The signals are processed to determine the orientation of the dosimeter in the reader, the location and state of punchcode holes in a two row array thereby decoding the encoded data. Multiple rate of fall calculations are made, and if appropriate matching of the punchcode array is not obtained in three tries, an error signal is output to the operator. The punchcode reader also provides for storage of data from multiple dosimeters passed through the reader, and for the output of decoded data to an external display or a computer for further processing. 8 figs.

  13. Method and apparatus for reading free falling dosimeter punchcodes

    DOEpatents

    Langsted, James M.

    1992-12-22

    A punchcode reader is provided for reading data encoded in a punchcode hole array on a dosimeter. The dosimeter falls through a passage in the reader containing photosensor detectors disposed along the passage which provide output signals to a microprocessor. The signals are processed to determine the orientation of the dosimeter in the reader, the location and state of punchcode holes in a two row array thereby decoding the encoded data. Multiple rate of fall calculations are made, and if appropriate matching of the punchcode array is not obtained in three tries, an error signal is outputted to the operator. The punchcode reader also provides for storage of data from multiple dosimeters passed through the reader, and for the output of decoded data to an external display or a computer for further processing.

  14. Antioxidant effect of green tea on polymer gel dosimeter

    NASA Astrophysics Data System (ADS)

    Samuel, E. J. J.; Sathiyaraj, P.; Deena, T.; Kumar, D. S.

    2015-01-01

    Extract from Green Tea (GTE) acts as an antioxidant in acrylamide based polymer gel dosimeter. In this work, PAGAT gel was used for investigation of antioxidant effect of GTE.PAGAT was called PAGTEG (Polyacrylamide green tea extract gel dosimeter) after adding GTE. Free radicals in water cause pre polymerization of polymer gel before irradiation. Polyphenols from GTE are highly effective to absorb the free radicals in water. THPC is used as an antioxidant in polymer gel dosimeter but here we were replaced it by GTE and investigated its effect by spectrophotometer. GTE added PAGAT samples response was lower compared to THPC added sample. To increase the sensitivity of the PAGTEG, sugar was added. This study confirmed that THPC was a good antioxidant for polymer gel dosimeter. However, GTE also can be used as an antioxidant in polymer gel if use less quantity (GTE) and add sugar as sensitivity enhancer.

  15. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    DOEpatents

    Vo-Dinh, T.

    1995-03-21

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devices, in probe array devices. 10 figures.

  16. Methods and means of checking thermoluminescent and radiophotoluminescent dosimeters

    SciTech Connect

    Fominykh, V.I.; Oborin, A.V.; Sebekin, A.P.; Uryaev, I.A.

    1987-06-01

    The authors discuss methods of checking thermoluminescent and radiophotoluminescent dosimeters which are used often in monitoring radiation safety in various areas including nuclear power stations. When the dosimeters are checked in the fields of standard beta-ray sources, it is recommended that the standard absorbed-dose or equivalent-dose measures for beta radiation should be sources of /sup 90/Sr + /sup 90/Y, /sup 204/Tl, and /sup 147/Pm. Various safety guidelines are discussed.

  17. Surface-enhanced Raman scattering (SERS) dosimeter and probe

    DOEpatents

    Vo-Dinh, Tuan

    1995-01-01

    A dosimeter and probe for measuring exposure to chemical and biological compounds is disclosed. The dosimeter or probe includes a collector which may be analyzed by surface-enhanced Raman spectroscopy. The collector comprises a surface-enhanced Raman scattering-active material having a coating applied thereto to improve the adsorption properties of the collector. The collector may also be used in automated sequential devises, in probe array devices.

  18. A neutron dosemeter for nuclear criticality accidents.

    PubMed

    d'Errico, F; Curzio, G; Ciolini, R; Del Gratta, A; Nath, R

    2004-01-01

    A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets. PMID:15353696

  19. Potential High Resolution Dosimeters For MRT

    NASA Astrophysics Data System (ADS)

    Bräuer-Krisch, E.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Brochard, T.; Kamlowski, A.; Cellere, G.; Paccagnella, A.; Siegbahn, E. A.; Prezado, Y.; Martinez-Rovira, I.; Bravin, A.; Dusseau, L.; Berkvens, P.

    2010-07-01

    resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic® films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al2O3:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1×1 cm5 field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

  20. Potential High Resolution Dosimeters For MRT

    SciTech Connect

    Braeuer-Krisch, E.; Brochard, T.; Prezado, Y.; Bravin, A.; Berkvens, P.; Rosenfeld, A.; Lerch, M.; Petasecca, M.; Akselrod, M.; Sykora, J.; Bartz, J.; Ptaszkiewicz, M.; Olko, P.; Berg, A.; Wieland, M.; Doran, S.; Kamlowski, A.; Cellere, G.

    2010-07-23

    /s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

  1. Fast neutron dosimeter using Cooled Optically Stimulated Luminescence (COSL)

    SciTech Connect

    Eschbach, P.A.; Miller, S.D.

    1991-10-01

    Data is presented that demonstrates the concept of a fast neutron dosimeter using Cooled Optically Stimulated Luminescence. CaF{sub 2}:Mn powder, compounded with polyethylene, was injection molded and pressed into 0.1-cm-thick sheets. The sheets were then cut to form dosimeters with dimensions, 1.25 cm by 1.25 cm. After a laser anneal, the dosimeters were exposed to various amounts (from 10 mSv to 100 mSv) of fast {sup 252}Cf neutrons. The exposed dosimeters were cooled to liquid nitrogen temperature, stimulated with laser light, and then allowed to warm up to room temperature whereupon the dose dependent luminescence was recorded with a photon counting system. When the control and gamma components were subtracted from the {sup 252}Cf response, a dose-dependent neutron response was observed. The design, construction, and preliminary performance of an automated system for the dose interrogation of individual CaF{sub 2}:Mn grains within the polyethylene matrix will also be discussed. The system uses a small CO{sub 2} laser to heat areas of the cooled dosimeter to room temperature. If the readout of very small grain within the plastic matrix is successful, it will enhance the neutron to gamma response of the dosimeter.

  2. Radiation measured with passive dosimeters in low Earth orbit

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Semones, E.; Gaza, R.; Weyland, M.

    begin center Radiation Measured with Passive Dosimeters in Low Earth Orbit end center begin center D Zhou 1 2 E Semones 1 R Gaza 1 2 M Weyland 1 end center begin center 1 Johnson Space Center - NASA 2101 Nasa Road 1 Houston 77058 USA end center begin center 2 Universities Space Research Association 2101 Nasa Parkway Houston 77058 USA end center begin center Abstract end center The linear energy transfer LET of particles in low Earth orbit LEO is extended from sim 0 1 to sim 1000 keV mu m water The best passive dosimeters for the radiation measurement are thermoluminescence dosimeters TLDs or optically stimulated luminescence dosimeters OSLDs for low LET and CR-39 plastic nuclear track detectors PNTDs for high LET Radiation quantities fluence absorbed dose dose equivalent and quality factor were measured with the passive dosimeters composed of TLDs OSLDs and CR-39 PNTDs for STS-114 mission This paper introduces the operation principles for TLDs OSLDs and CR-39 PNTDs describes the method to combine the results measured by TLDs OSLDs and CR-39 PNTDs and presents the results measured by different dosimeters for different LET band and that combined for all LET

  3. Response of the Hanford Combination Neutron Dosimeter in plutonium environments

    SciTech Connect

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.

    1996-02-01

    This report documents response characteristics and the development of dose algorithms for the Hanford Combination Neutron Dosimeter (HCNO) implemented on January 1, 1995. The HCND was accredited under the U.S. Department of Energy (DOE) Laboratory Accreditation Program (DOELAP) during 1994. The HCND employs two neutron dose components consisting of (1) an albedo thermoluminescent dosimeter (TLD), and (2) a track-etch dosimeter (TED). Response characteristics of these two dosimeter components were measured under the low-scatter conditions of the Hanford 318 Building Calibration Laboratory, and under the high-scatter conditions in the workplace at the Plutonium Finishing Plant (PFP). The majority of personnel neutron dose at Hanford (currently and historically) occurs at the PFP. National Institute of Standards and Technology (NIST) traceable sources were used to characterize dosimeter response in the laboratory. At the PFP, neutron spectra and dose-measuring instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters, were used to determine the neutron dose under several configurations from three different plutonium sources: (1) plutonium tetrafluoride, (2) plutonium metal, and (3) plutonium oxide. In addition, measurements were performed at many selected work locations. The HCNDs were included in all measurements. Comparison of dosimeter- and instrument-measured dose equivalents provided the data necessary to develop HCND dose algorithms and to assess the accuracy of estimated neutron dose under actual work conditions.

  4. Airborne intercomparison of nitric oxide measurement techniques

    NASA Technical Reports Server (NTRS)

    Hoell, James M., Jr.; Gregory, Gerald L.; Mcdougal, David S.; Torres, Arnold L.; Davis, Douglas D.

    1987-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted during missions flown in the fall of 1983 and spring of 1984. Instruments intercompared included a laser-induced fluorescence (LIF) system and two chemiluminescence instruments (CL). NO mixing ratios from below 5 pptv (parts per trillion by volume) to greater than 100 pptv were reported, with the majority less than 20 pptv. Good correlation was observed between the measurements reported by the CL and LIF techniques. The general level of agreement observed for the ensemble of measurements obtained during the two missions provides the basis from which one can conclude that equally 'valid' measurements of background levels of NO can be expected from either CL or LIF instruments. At the same time the periods of disagreement that were observed between the CL and LIF instruments as well as between the two CL instruments highlight the difficulty of obtaining reliable measurements with NO mixing ratios in the 5-20 pptv range and emphasize the vigilance that should be maintained in future NO measurements.

  5. Intercomparison of ozone measurements over Antarctica

    SciTech Connect

    Margitan, J.J.; Farmer, C.B.; Toon, G.C. ); Brothers, G.A. ); Browell, E.V.; Gregory, G.L.; Hypes, W.; Larsen, J.C.; McCormick, M.P. ); Cariolle, D. ); Coffey, M.T.; Mankin, W. ); Farman, J.C. ); Harder, J.W.; Mount, G.H.; Ravishankara, A.R.; Schemeltekopf, A.L.; Tuck, A.F. ); Hofmann, D.J. ); Ismail, S.; Kooi, S. ); Jakoubek, R.O.; Proffitt, M.H.; Wahner, A.; Watterson, I. Univ. of Colorado, Boulder ); Komhyr, W. (NOAA Air Resources La

    1989-11-30

    Measurements of the abundances of ozone over Antarctic in August and September 1987 obtained during the Airborne Antarctic Ozone Experiment are intercompared. These measurements of ozone concentrations and total column abundance were obtained by three satellite instruments, two IR and one UV column-measuring instruments aboard the DC-8, one in situ DC-8, and two in situ ER-2 instruments, an upward looking lidar aboard the DC-8, and ozonesondes from four sites in Antarctica. Given the natural variability of ozone in the Antarctic and the fact that the data were not truly coincident spatially and temporally, this intercomparison is suitable only for identifying gross disparities among the techniques, rather than confirming the accuracies as rigorously as is normally done in an intercomparison. This paper presents a summary of the ozone data, using the data and accuracies given by the individual investigators in the individual papers in this issue, without any attempt to critically review or evaluate the data. In general, very good agreement (within about 10-20%, limited by natural variability) among the various techniques was found, with no systematic biases detected. These observations confirm the low ozone amounts reported in the Antarctic stratosphere.

  6. An intercomparison of ESR and uranium series ages for quaternary speleothem calcites

    NASA Astrophysics Data System (ADS)

    Smart, P. L.; Smith, B. W.; Chandra, H.; Andrews, J. N.; Symons, M. C. R.

    Equivalent dose (ED) estimates for speleothem calcite derived by ESR measurements of the g = 2.0005 signal have a typical precision of ±7% (minimum ±2%), and depend on the signal strength, radiation sensitivity and the presence of interfering signals. Underestimation of ED will occur if the crushing signal at g = 2.0001 is not removed by acid etching, while overestimation may be caused if the short-lived radiation induced interfering signal at g = 2.0020 is not removed by annealing. Quoted errors for ESR ages are rarely better than ±10% and are typically ±15% because of uncertainties in ED, calibration of dosimeters and gamma source, and in the a-value. Serial analyses along the growth axis of single speleothems, and between speleothems interbedded in a sequence demonstrate excellent stratigraphic concordance. Intercomparison of ESR and uranium series ages for samples derived from 11 geographically diverse sites show good agreement with no indication of systematic error. Although validation is more difficult for samples beyond the limit of {230Th}/{234U} dating, the results appear encouraging, but recrystallisation and changes in the external radiation dose may cause problems.

  7. Solid state neutron dosimeter for space applications

    NASA Technical Reports Server (NTRS)

    Entine, Gerald; Nagargar, Vivek; Sharif, Daud

    1990-01-01

    Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.

  8. PDT dose dosimeter for pleural photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Kim, Michele M.; Darafsheh, Arash; Ahmad, Mahmoud; Finlay, Jarod C.; Zhu, Timothy C.

    2016-03-01

    PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), a PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously in the same treatment location. Light fluence and spectral data were rigorously compared to other methods of measurement (e.g. photodiode, multi-fiber spectroscopy contact probe) to assess the accuracy of the measurements as well as their uncertainty. Photosensitizer concentration was obtained by measuring the fluorescence of the sensitizer excited by the treatment light. Fluence rate based on the intensity of the laser spectrum was compared to the data obtained by direct measurement of fluence rate by a fiber-coupled photodiode. Phantom studies were done to obtain an optical property correction for the fluorescence signal. Measurements were performed in patients treated Photofrin for different locations in the pleural cavity. Multiple sites were measured to investigate the heterogeneity of the cavity and to provide cross-validation via relative dosimetry. This novel method will allow for accurate real-time determination of delivered PDT dose and improved PDT dosimetry.

  9. Preliminary evaluation of implantable MOSFET radiation dosimeters.

    PubMed

    Beddar, A S; Salehpour, M; Briere, T M; Hamidian, H; Gillin, M T

    2005-01-01

    In this paper, we report on measurements performed on a new prototype implantable radiation detector that uses metal-oxide semiconductor field effect transistors (MOSFETs) designed for in vivo dosimetry. The dosimeters, which are encapsulated in hermetically sealed glass cylinders, are used in an unbiased mode during irradiation, unlike other MOSFET detectors previously used in radiotherapy applications. They are powered by radio frequency telemetry for dose measurements, obviating the need for a power supply within each capsule. We have studied the dosimetric characteristics of these MOSFET detectors in vitro under irradiation from a 60Co source. The detectors show a dose reproducibility generally within 5% or better, with the main sources of error being temperature fluctuations occurring between the pre- and post-irradiation measurements as well as detector orientation. A better temperature-controlled environment leads to a reproducibility within 2%. Our preliminary in vitro results show clearly that true non-invasive in vivo dosimetry measurements are feasible and can be performed remotely using telemetric technology. PMID:15715428

  10. PDT Dose Dosimeter for Pleural Photodynamic Therapy

    PubMed Central

    Kim, Michele M.; Darafsheh, Arash; Ahmad, Mahmoud; Finlay, Jarod C.; Zhu, Timothy C.

    2016-01-01

    PDT dose is the product of the photosensitizer concentration and the light fluence in the target tissue. For improved dosimetry during plural photodynamic therapy (PDT), a PDT dose dosimeter was developed to measure both the light fluence and the photosensitizer concentration simultaneously in the same treatment location. Light fluence and spectral data were rigorously compared to other methods of measurement (e.g. photodiode, multi-fiber spectroscopy contact probe) to assess the accuracy of the measurements as well as their uncertainty. Photosensitizer concentration was obtained by measuring the fluorescence of the sensitizer excited by the treatment light. Fluence rate based on the intensity of the laser spectrum was compared to the data obtained by direct measurement of fluence rate by a fiber-coupled photodiode. Phantom studies were done to obtain an optical property correction for the fluorescence signal. Measurements were performed in patients treated Photofrin for different locations in the pleural cavity. Multiple sites were measured to investigate the heterogeneity of the cavity and to provide cross-validation via relative dosimetry. This novel method will allow for accurate real-time determination of delivered PDT dose and improved PDT dosimetry. PMID:27053825

  11. Worms in space? A model biological dosimeter.

    PubMed

    Zhao, Yang; Johnsen, Robert; Baillie, David; Rose, Ann

    2005-06-01

    Although it is well known that radiation causes mutational damage, little is known about the biological effects of long-term exposure to radiation in space. Exposure to radiation can result in serious heritable defects in experimental animals, and in humans, susceptibility to cancer, radiation-sickness, and death at high dosages. It is possible to do ground controlled studies of different types of radiation on experimental animals and to physically measure radiation on the space station or on space probes. However, the actual biological affects of long-term exposure to the full range of space radiation have not been studied, and little information is available about the biological consequences of solar flares. Biological systems are not simply passive recording instruments. They respond differently under different conditions, and thus it is important to be able to collect data from a living animal. There are technical difficulties that restrict the placement of an experimental organism in a space environment for long periods of time, in a manner that allows for the recovery of genetic data. Use of the self-fertilizing hermaphroditic nematode, Caenorhabditis elegans offers potential for the design of a biological dosimeter. In this paper, we describe the advantages of this model system and review the literature of C. elegans in space. PMID:16038089

  12. Solid state neutron dosimeter for space applications

    NASA Astrophysics Data System (ADS)

    Entine, Gerald; Nagargar, Vivek; Sharif, Daud

    1990-08-01

    Personnel engaged in space flight are exposed to significant flux of high energy neutrons arising from both primary and secondary sources of ionizing radiation. Presently, there exist no compact neutron sensor capable of being integrated in a flight instrument to provide real time measurement of this radiation flux. A proposal was made to construct such an instrument using special PIN silicon diode which has the property of being insensitive to the other forms of ionizing radiation. Studies were performed to determine the design and construction of a better reading system to allow the PIN diode to be read with high precision. The physics of the device was studied, especially with respect to those factors which affect the sensitivity and reproducibility of the neutron response. This information was then used to develop methods to achieve high sensitivity at low neutron doses. The feasibility was shown of enhancing the PIN diode sensitivity to make possible the measurement of the low doses of neutrons encountered in space flights. The new PIN diode will make possible the development of a very compact, accurate, personal neutron dosimeter.

  13. Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: radiometer standards

    SciTech Connect

    Estey, R.S.; Seaman, C.H.

    1981-07-01

    Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

  14. Intercomparison of hydrologic processes in global climate models

    NASA Technical Reports Server (NTRS)

    Lau, W. K.-M.; Sud, Y. C.; Kim, J.-H.

    1995-01-01

    In this report, we address the intercomparison of precipitation (P), evaporation (E), and surface hydrologic forcing (P-E) for 23 Atmospheric Model Intercomparison Project (AMIP) general circulation models (GCM's) including relevant observations, over a variety of spatial and temporal scales. The intercomparison includes global and hemispheric means, latitudinal profiles, selected area means for the tropics and extratropics, ocean and land, respectively. In addition, we have computed anomaly pattern correlations among models and observations for different seasons, harmonic analysis for annual and semiannual cycles, and rain-rate frequency distribution. We also compare the joint influence of temperature and precipitation on local climate using the Koeppen climate classification scheme.

  15. Angular dependence of mammographic dosimeters in digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Bradley, Lena R.; Carton, Ann-Katherine; Maidment, Andrew D. A.

    2010-04-01

    Digital Breast Tomosynthesis (DBT) is an emerging imaging modality that combines tomography with conventional digital mammography. In developing DBT dosimetry, a direct application of mammographic dosimetry has appeal. However, DBT introduces rotation of the x-ray tube relative to the dosimeter, thus raising questions about the angular dependence of mammographic dosimeters. To measure this dependence, two ionization chambers, two solid-stated detectors, and one photodiode were rotated relative to an incident Mo/Mo x-ray beam. In this isocentric DBT simulation, the signal of each dosimeter was studied over an angular range of 180° for tube voltages of 26 to 34 kV. One ionization chamber was then modeled numerically to study the response to various monoenergetic beams. The results show that all dosimeters underestimate dose to varying degrees; solid-state detectors show the greatest angular dependence while ionization chambers show the least. Correction factors were computed from the data for isocentric DBT images using projection angles up to +/-25° these factors ranged from 1.0014 to 1.1380. The magnitude of the angular dependence generally decreased with increasing energy, as shown with both the measured and modeled data. As a result, the error arising in measuring DBT dose with a mammographic dosimeter varies significantly; it cannot always be disregarded. The use of correction factors may be possible but is largely impractical, as they are specific to the dosimeter, x-ray beam, and DBT geometry. Instead, an angle-independent dosimeter may be more suitable for DBT.

  16. World commercial aircraft accidents

    SciTech Connect

    Kimura, C.Y.

    1993-01-01

    This report is a compilation of all accidents world-wide involving aircraft in commercial service which resulted in the loss of the airframe or one or more fatality, or both. This information has been gathered in order to present a complete inventory of commercial aircraft accidents. Events involving military action, sabotage, terrorist bombings, hijackings, suicides, and industrial ground accidents are included within this list. Included are: accidents involving world commercial jet aircraft, world commercial turboprop aircraft, world commercial pistonprop aircraft with four or more engines and world commercial pistonprop aircraft with two or three engines from 1946 to 1992. Each accident is presented with information in the following categories: date of the accident, airline and its flight numbers, type of flight, type of aircraft, aircraft registration number, construction number/manufacturers serial number, aircraft damage, accident flight phase, accident location, number of fatalities, number of occupants, cause, remarks, or description (brief) of the accident, and finally references used. The sixth chapter presents a summary of the world commercial aircraft accidents by major aircraft class (e.g. jet, turboprop, and pistonprop) and by flight phase. The seventh chapter presents several special studies including a list of world commercial aircraft accidents for all aircraft types with 100 or more fatalities in order of decreasing number of fatalities, a list of collision accidents involving commercial aircrafts, and a list of world commercial aircraft accidents for all aircraft types involving military action, sabotage, terrorist bombings, and hijackings.

  17. Intercomparison of measurements of stratospheric hydrogen fluoride

    NASA Technical Reports Server (NTRS)

    Mankin, William G.; Coffey, M. T.; Chance, K. V.; Traub, W. A.; Carli, B.; Mencaraglia, F.; Piccioli, S.; Farmer, C. B.; Seals, R. K.

    1990-01-01

    Observations of the vertical profile of hydrogen fluoride (HF) vapor in the stratosphere and of the vertical column amounts of HF above certain altitudes were made using a variety of spectroscopic instruments in the 1982 and 1983 Balloon Intercomparison Campaigns. Both emission instruments working in the far-infrared spectral region and absorption instruments using solar occultation in the 2.5-micron region were employed. No systematic differences were seen in results from the two spectral regions. A mean profile from 20 - 45 km is presented, with uncertainties ranging from 20 to 50 percent. Total columns measured from ground and from 12 km are consistent with the profile if the mixing ratio for HF is small in the troposphere and low stratosphere.

  18. Ozone measurements from the Balloon Intercomparison Campaign

    NASA Astrophysics Data System (ADS)

    Robbins, D.; Waters, J.; Zimmermann, P.; Jarnot, R.; Hardy, J.; Pickett, H.; Pollitt, S.; Traub, W.; Chance, K.; Louisnard, N.; Evans, W.; Kerr, J.

    1990-02-01

    Measurements of the Balloon Intercomparison Campaign (BIC), conducted during fall, 1982 (BIC-1) and summer, 1983 (BIC-2), are reported. Results of five remote and two in situ techniques agree (with a few exceptions) within 95-percent confidence level uncertainties and generally within 15 percent above 20 km. Weighted mean profiles, which best represent conditions during the campaign, are used as a comparison standard. Accuracies of experiments indicated by BIC generally confirm estimated uncertainties for ECC sondes, UV photometry, and microwave emission experiments, are somewhat better for far-IR emission and IR absorption experiments, and are somewhat worse for IR emission and solar UV absorption experiments. The large collection of BIC measurements confirms a problem reported earlier with current theoretical modeling of ozone near 40 km.

  19. The SPARC Intercomparison of Middle Atmosphere Climatologies

    NASA Technical Reports Server (NTRS)

    Randel, William; Fleming, Eric; Geller, Marvin; Gelman, Mel; Hamilton, Kevin; Karoly, David; Ortland, Dave; Pawson, Steve; Swinbank, Richard; Udelhofen, Petra

    2003-01-01

    Our current confidence in 'observed' climatological winds and temperatures in the middle atmosphere (over altitudes approx. 10-80 km) is assessed by detailed intercomparisons of contemporary and historic data sets. These data sets include global meteorological analyses and assimilations, climatologies derived from research satellite measurements, and historical reference atmosphere circulation statistics. We also include comparisons with historical rocketsonde wind and temperature data, and with more recent lidar temperature measurements. The comparisons focus on a few basic circulation statistics, such as temperature, zonal wind, and eddy flux statistics. Special attention is focused on tropical winds and temperatures, where large differences exist among separate analyses. Assimilated data sets provide the most realistic tropical variability, but substantial differences exist among current schemes.

  20. Inter-comparison of automatic rain gauges

    NASA Technical Reports Server (NTRS)

    Nystuen, Jeffrey A.

    1994-01-01

    The Ocean Acoustics Division (OAD) of the Atlantic Oceanographic and Meteorological Laboratory (AOML), in cooperation with NOAA/NESDIS and NASA, has deployed six rain gauges for calibration and intercomparison purposes. These instruments include: (1) a weighing rain gauge, (2) a RM Young Model 50202 capacitance rain gauge, (3) a ScTI ORG-705 (long path) optical rain gauge, (4) a ScTI ORG-105 (mini-ORG) optical rain gauge, (5) a Belfort Model 382 tipping bucket rain gauge, and (6) a Distromet RD-69 disdrometer. The system has been running continuously since July 1993. During this time period, roughly 150 events with maximum rainfall rate over 10 mm/hr and 25 events with maximum rainfall rates over 100 mm/hr have been recorded. All rain gauge types have performed well, with intercorrelations 0.9 or higher. However, limitations for each type of rain gauge have been observed.

  1. The Pliocene Model Intercomparison Project - Phase 2

    NASA Astrophysics Data System (ADS)

    Haywood, Alan; Dowsett, Harry; Dolan, Aisling; Rowley, David; Abe-Ouchi, Ayako; Otto-Bliesner, Bette; Chandler, Mark; Hunter, Stephen; Lunt, Daniel; Pound, Matthew; Salzmann, Ulrich

    2016-04-01

    The Pliocene Model Intercomparison Project (PlioMIP) is a co-ordinated international climate modelling initiative to study and understand climate and environments of the Late Pliocene, and their potential relevance in the context of future climate change. PlioMIP examines the consistency of model predictions in simulating Pliocene climate, and their ability to reproduce climate signals preserved by geological climate archives. Here we provide a description of the aim and objectives of the next phase of the model intercomparison project (PlioMIP Phase 2), and we present the experimental design and boundary conditions that will be utilised for climate model experiments in Phase 2. Following on from PlioMIP Phase 1, Phase 2 will continue to be a mechanism for sampling structural uncertainty within climate models. However, Phase 1 demonstrated the requirement to better understand boundary condition uncertainties as well as uncertainty in the methodologies used for data-model comparison. Therefore, our strategy for Phase 2 is to utilise state-of-the-art boundary conditions that have emerged over the last 5 years. These include a new palaeogeographic reconstruction, detailing ocean bathymetry and land/ice surface topography. The ice surface topography is built upon the lessons learned from offline ice sheet modelling studies. Land surface cover has been enhanced by recent additions of Pliocene soils and lakes. Atmospheric reconstructions of palaeo-CO2 are emerging on orbital timescales and these are also incorporated into PlioMIP Phase 2. New records of surface and sea surface temperature change are being produced that will be more temporally consistent with the boundary conditions and forcings used within models. Finally we have designed a suite of prioritized experiments that tackle issues surrounding the basic understanding of the Pliocene and its relevance in the context of future climate change in a discrete way.

  2. Designing an Experimental "Accident"

    ERIC Educational Resources Information Center

    Picker, Lester

    1974-01-01

    Describes an experimental "accident" that resulted in much student learning, seeks help in the identification of nematodes, and suggests biology teachers introduce similar accidents into their teaching to stimulate student interest. (PEB)

  3. Site-specific calibration of the Hanford personnel neutron dosimeter

    SciTech Connect

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.; Rathbone, B.A.

    1994-10-01

    A new personnel dosimetry system, employing a standard Hanford thermoluminescent dosimeter (TLD) and a combination dosimeter with both CR-39 nuclear track and TLD-albedo elements, is being implemented at Hanford. Measurements were made in workplace environments in order to verify the accuracy of the system and establish site-specific factors to account for the differences in dosimeter response between the workplace and calibration laboratory. Neutron measurements were performed using sources at Hanford`s Plutonium Finishing Plant under high-scatter conditions to calibrate the new neutron dosimeter design to site-specific neutron spectra. The dosimeter was also calibrated using bare and moderated {sup 252}Cf sources under low-scatter conditions available in the Hanford Calibration Laboratory. Dose equivalent rates in the workplace were calculated from spectrometer measurements using tissue equivalent proportional counter (TEPC) and multisphere spectrometers. The accuracy of the spectrometers was verified by measurements on neutron sources with calibrations directly traceable to the National Institute of Standards and Technology (NIST).

  4. Dose rate dependency of micelle leucodye 3D gel dosimeters

    NASA Astrophysics Data System (ADS)

    Vandecasteele, J.; Ghysel, S.; De Deene, Y.

    2010-11-01

    Recently a novel 3D radiochromic gel dosimeter was introduced which uses micelles to dissolve a leucodye in a gelatin matrix. Experimental results show that this 3D micelle gel dosimeter was found to be dose rate dependent. A maximum difference in optical dose sensitivity of 70% was found for dose rates between 50 cGy min-1 and 400 cGy min-1. A novel composition of 3D radiochromic dosimeter is proposed composed of gelatin, sodium dodecyl sulphate, chloroform, trichloroacetic acid and leucomalachite green. The novel gel dosimeter formulation exhibits comparable radio-physical properties in respect to the composition previously proposed. Nevertheless, the novel formulation was found to be still dose rate dependent. A maximum difference of 33% was found for dose rates between 50 cGy min-1 and 400 cGy min-1. On the basis of these experimental results it is concluded that the leucodye micelle gel dosimeter is still unsatisfactory for clinical radiation therapy dose verifications. Some insights in the physico-chemical mechanisms were obtained and are discussed.

  5. International NMR-based Environmental Metabolomics Intercomparison Exercise

    EPA Science Inventory

    Several fundamental requirements must be met so that NMR-based metabolomics and the related technique of metabonomics can be formally adopted into environmental monitoring and chemical risk assessment. Here we report an intercomparison exercise which has evaluated the effectivene...

  6. Radioxenon standards used in laboratory inter-comparisons.

    PubMed

    Gohla, H; Auer, M; Cassette, Ph; Hague, R K; Lechermann, M; Nadalut, B

    2016-03-01

    Preparation methods for (133)Xe standards of activity concentration and the results of the 2014 (133)Xe laboratory inter-comparison exercise are described. One element of the quality assurance/quality control (QA/QC) program for laboratories of the International Monitoring System (IMS) will be regular inter-comparison exercises. However, until recently, no activity concentration standards for benchmarking were available. Therefore, two (133)Xe activity concentration reference standards were produced independently by Idaho National Laboratory and Seibersdorf Laboratories and used for the 2014 laboratory inter-comparison exercise. The preparation of a complementary (127)Xe activity concentration standard as well as a (127)Xe laboratory inter-comparison exercise suggests (127)Xe as a suitable isotope for QA/QC of remote IMS noble gas stations. PMID:26682890

  7. Luminescence techniques for dose reconstruction in accident situations: possibilites, limitations and uncertainties

    SciTech Connect

    Haskell, E.H.

    1996-12-31

    In a nuclear accident of even moderate size, locations will inevitably be exposed which do not have adequate monitoring. In these situations nontraditional dosimeters such as brick, tiles or other environmental materials have historically provided measurements against which models of transport and exposure could be tested. Given sufficient speed and accuracy, the utility of TL techniques applied to natural materials can extend well beyond model verification to a variety of dosimetric applications.

  8. US progress on the development of CR-39 based neutron dosimeters

    SciTech Connect

    Hadlock, D.E.

    1987-06-01

    Historically at US nuclear facilities, two types of personnel neutron dosimeters have been in routine use: nuclear track emulsion-Type A (NTA) film and thermoluminescent dosimeter (TLD)-albedo. Both of these dosimeters have energy-dependent responses. Therefore, the neutron energy spectra must be known, to interpret the dosimeter results properly. A new state-of-the-art dosimetry system has been developed within the US Department of Energy (US DOE) Personnel Neutron Dosimeter Evaluation and Upgrade Program. This system is called the combination thermoluminescent dosimeter/track etch dosimeter (TLD/TED). This paper briefly describes US DOE research currently being conducted to further enhance the TED portion of the combination TLD/TED system. The research areas involved include dose sensitivity, neutron energy range, specialized radiators, self-developing dosimeters, and neutron spectrometry. 1 fig., 1 tab.

  9. Commissioning and implementation of an implantable dosimeter for radiation therapy.

    PubMed

    Buzurovic, Ivan; Showalter, Timothy N; Studenski, Matthew T; Den, Robert B; Dicker, Adam P; Cao, Junsheng; Xiao, Ying; Yu, Yan; Harrison, Amy

    2013-01-01

    In this article we describe commissioning and implementation procedures for the Dose Verification System (DVS) with permanently implanted in vivo wireless, telemetric radiation dosimeters for absolute dose measurements. The dosimeter uses a semiconductor device called a metal-oxide semiconductor field-effect transistor (MOSFET) to measure radiation dose. A MOSFET is a transistor that is generally used for amplifying or switching electronic signals. The implantable dosimeter was implemented with the goal of verifying the dose delivered to radiation therapy patients. For the purpose of acceptance testing, commissioning, and clinical implementation and to evaluate characteristics of the dosimeter, the following tests were performed: 1) temperature dependence, 2) reproducibility,3) field size dependence, 4) postirradiation signal drift, 5) dependence on average dose rate, 6) linearity test, 7) angular dependence (different gantry angle position), 8) angular dependence (different DVS angle position), 9) dose rate dependence,10) irradiation depth dependence, 11) effect of cone-beam exposure to the dosimeter, and 12) multiple reading effect. The dosimeter is not currently calibrated for use in the kV range; nonetheless, the effect of the cone-beam procedure on the MOSFET dosimeter was investigated. Phantom studies were performed in both air and water using an Elekta Synergy S Beam-Modulator linear accelerator. Commissioning and clinical implementation for prostate cancer patients receiving external-beam radiation therapy were performed in compliance with the general recommendations given for in vivo dosimetry devices. The reproducibility test in water at human body temperature (37°C) showed a 1.4% absolute difference, with a standard deviation of 5.72 cGy (i.e., SD = 2.9%). The constancy test shows that the average readings at room temperature were 3% lower compared to the readings at human body temperature, with a SD = 2%. Measurements were not dependent upon field size

  10. Photon and neutron kerma coefficients for polymer gel dosimeters

    NASA Astrophysics Data System (ADS)

    El-Khayatt, A. M.; Vega-Carrillo, Hector Rene

    2015-08-01

    Neutron and gamma ray kerma coefficients were calculated for 17 3D dosimeters, for the neutron and gamma ray energy ranges extend from 2.53×10-8 to 29 MeV and from 1.0×10-3 to 20 MeV, respectively. The calculated kermas given here for discrete energies and the kerma coefficients are referred to as "point-wise data". Curves of gamma ray kermas showed slight dips at about 60 keV for most 3D dosimeters. Also, a noticeable departure between thermal and epithermal neutrons kerma sets for water and polymers has been observed. Finally, the obtained results could be useful for dose estimation in the studied 3D dosimeters.

  11. Angular dependence of the nanoDot OSL dosimeter

    PubMed Central

    Kerns, James R.; Kry, Stephen F.; Sahoo, Narayan; Followill, David S.; Ibbott, Geoffrey S.

    2011-01-01

    Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight∕OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system.Methods: Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX.Results: When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found.Conclusions: A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions. PMID:21858992

  12. Implanted Dosimeters Identify Radiation Overdoses During IMRT for Prostate Cancer

    SciTech Connect

    Den, Robert B.; Nowak, Kamila; Buzurovic, Ivan; Cao Junsheng; Harrison, Amy S.; Lawrence, Yaacov R.; Dicker, Adam P.; Showalter, Timothy N.

    2012-07-01

    Purpose: Image-guided dose-escalated radiotherapy is the standard of care for the treatment of prostate cancer. Although many published methods are available that account for prostate motion during delivery, evidence demonstrating that the planned dose is actually delivered on a daily basis is lacking. We report our initial clinical experience using implantable dosimeters to quantify and adjust the dose received during intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients undergoing IMRT with cone-beam computed tomography (CT) image guidance for prostate cancer had the dose verification system with radiopaque metal-oxide-semiconductor field effect transistor dosimeters implanted before treatment planning. All patients underwent planning with CT simulation in the supine position with custom immobilization, and the implanted dosimeters were located in the IMRT plans. The predicted dose for each dosimeter was defined and compared with the wireless readings before and after each treatment session. Investigations by physicians and medical physicists were initiated for two or more discrepancies >6% for any five consecutive fractions or for any discrepancy {>=}10%. Results: Using implanted in vivo dosimeters, dose measurements consistently >6% greater than the predicted values were observed during treatment for 3 of 20 prostate cancer patients who received IMRT with daily image guidance. A review of the daily cone-beam CT images revealed acceptable alignment of the prostate target volumes and implanted dosimeters but identified significant anatomic changes within the treated region. Repeat CT simulation and RT planning was performed, with resolution of the dose discrepancies in all 3 cases with the adoption of a new IMRT plan. Conclusions: Our report illustrates the potential effect of implanted in vivo dosimetry for prostate IMRT and emphasizes the importance of careful planning and delivery with attention to systematic shifts or anatomic

  13. Development and evaluation of polycrystalline cadmium telluride dosimeters for accurate quality assurance in radiation therapy

    NASA Astrophysics Data System (ADS)

    Oh, K.; Han, M.; Kim, K.; Heo, Y.; Moon, C.; Park, S.; Nam, S.

    2016-02-01

    For quality assurance in radiation therapy, several types of dosimeters are used such as ionization chambers, radiographic films, thermo-luminescent dosimeter (TLD), and semiconductor dosimeters. Among them, semiconductor dosimeters are particularly useful for in vivo dosimeters or high dose gradient area such as the penumbra region because they are more sensitive and smaller in size compared to typical dosimeters. In this study, we developed and evaluated Cadmium Telluride (CdTe) dosimeters, one of the most promising semiconductor dosimeters due to their high quantum efficiency and charge collection efficiency. Such CdTe dosimeters include single crystal form and polycrystalline form depending upon the fabrication process. Both types of CdTe dosimeters are commercially available, but only the polycrystalline form is suitable for radiation dosimeters, since it is less affected by volumetric effect and energy dependence. To develop and evaluate polycrystalline CdTe dosimeters, polycrystalline CdTe films were prepared by thermal evaporation. After that, CdTeO3 layer, thin oxide layer, was deposited on top of the CdTe film by RF sputtering to improve charge carrier transport properties and to reduce leakage current. Also, the CdTeO3 layer which acts as a passivation layer help the dosimeter to reduce their sensitivity changes with repeated use due to radiation damage. Finally, the top and bottom electrodes, In/Ti and Pt, were used to have Schottky contact. Subsequently, the electrical properties under high energy photon beams from linear accelerator (LINAC), such as response coincidence, dose linearity, dose rate dependence, reproducibility, and percentage depth dose, were measured to evaluate polycrystalline CdTe dosimeters. In addition, we compared the experimental data of the dosimeter fabricated in this study with those of the silicon diode dosimeter and Thimble ionization chamber which widely used in routine dosimetry system and dose measurements for radiation

  14. Monte Carlo simulation experiments on box-type radon dosimeter

    NASA Astrophysics Data System (ADS)

    Jamil, Khalid; Kamran, Muhammad; Illahi, Ahsan; Manzoor, Shahid

    2014-11-01

    Epidemiological studies show that inhalation of radon gas (222Rn) may be carcinogenic especially to mine workers, people living in closed indoor energy conserved environments and underground dwellers. It is, therefore, of paramount importance to measure the 222Rn concentrations (Bq/m3) in indoors environments. For this purpose, box-type passive radon dosimeters employing ion track detector like CR-39 are widely used. Fraction of the number of radon alphas emitted in the volume of the box type dosimeter resulting in latent track formation on CR-39 is the latent track registration efficiency. Latent track registration efficiency is ultimately required to evaluate the radon concentration which consequently determines the effective dose and the radiological hazards. In this research, Monte Carlo simulation experiments were carried out to study the alpha latent track registration efficiency for box type radon dosimeter as a function of dosimeter's dimensions and range of alpha particles in air. Two different self developed Monte Carlo simulation techniques were employed namely: (a) Surface ratio (SURA) method and (b) Ray hitting (RAHI) method. Monte Carlo simulation experiments revealed that there are two types of efficiencies i.e. intrinsic efficiency (ηint) and alpha hit efficiency (ηhit). The ηint depends upon only on the dimensions of the dosimeter and ηhit depends both upon dimensions of the dosimeter and range of the alpha particles. The total latent track registration efficiency is the product of both intrinsic and hit efficiencies. It has been concluded that if diagonal length of box type dosimeter is kept smaller than the range of alpha particle then hit efficiency is achieved as 100%. Nevertheless the intrinsic efficiency keeps playing its role. The Monte Carlo simulation experimental results have been found helpful to understand the intricate track registration mechanisms in the box type dosimeter. This paper explains that how radon concentration from the

  15. Method of protecting a radiochromic optical waveguide dosimeter from adverse temperature effects. Patent Application

    SciTech Connect

    Kronenberg, S.

    1985-09-26

    A radiochromic optical waveguide dosimeter is protected from the adverse temperature effects of exposure in the desired operational temperature range of -40 C to +60 C by flattening the round plastic tubing to be used for the fabrication of the dosimeter until the tubing attains an elliptical cross section and then fabricating the dosimeter from the tubing having the elliptical cross section.

  16. The Pliocene Model Intercomparison Project - Phase 2

    NASA Astrophysics Data System (ADS)

    Haywood, Alan; Dowsett, Harry; Dolan, Aisling; Rowley, David; Abe-Ouchi, Ayako; Otto-Bliesner, Bette; Chandler, Mark; Lunt, Daniel; Salzmann, Ulrich

    2015-04-01

    The Pliocene Model Intercomparison Project (PlioMIP) is a coordinated international climate modelling initiative designed to understand climate and environments of the Late Pliocene, and their potential relevance in the context of future climate change. PlioMIP operates under the umbrella of the Palaeoclimate Modelling Intercomparison Project (PMIP), which examines multiple intervals in Earth history, the consistency of model predictions in simulating these intervals and their ability to reproduce climate signals preserved in geological climate archives. PlioMIP was initiated in 2008 and is closely aligned with the U.S. Geological Survey project known as PRISM (Pliocene Research Interpretation and Synoptic Mapping). PRISM has spent more than 25 years reconstructing and understanding mid-Pliocene climate (~3.3 to 3 million years ago), as well producing boundary condition data sets suitable for use with numerical climate models. The first phase of the PlioMIP (PlioMIP1: 2008-2014) resulted in the most complete analysis to date of the Pliocene climate. This included examination of large-scale features of global climate, detailed analyses of Pliocene ocean circulation and monsoon behaviour, and the ability of models to reproduce regional climate patterns reconstructed from both marine and terrestrial archives. The lessons learned from PlioMIP1 facilitated a revision of data and modelling approaches towards the understanding of the mid Pliocene. PlioMIP2 has now been launched, and includes significant improvements to many of the Pliocene palaeogeograhic boundary conditions used for driving climate models (new land/sea mask, topography, bathymetry and ice sheet reconstructions). Within Phase 2 modelling groups have the option of using dynamic global vegetation models to predict (rather than prescribe) land cover, and a broader portfolio of model experiments has been proposed to support efforts to better understand the Pliocene, as well as to use the Pliocene as a means

  17. Visualization of Traffic Accidents

    NASA Technical Reports Server (NTRS)

    Wang, Jie; Shen, Yuzhong; Khattak, Asad

    2010-01-01

    Traffic accidents have tremendous impact on society. Annually approximately 6.4 million vehicle accidents are reported by police in the US and nearly half of them result in catastrophic injuries. Visualizations of traffic accidents using geographic information systems (GIS) greatly facilitate handling and analysis of traffic accidents in many aspects. Environmental Systems Research Institute (ESRI), Inc. is the world leader in GIS research and development. ArcGIS, a software package developed by ESRI, has the capabilities to display events associated with a road network, such as accident locations, and pavement quality. But when event locations related to a road network are processed, the existing algorithm used by ArcGIS does not utilize all the information related to the routes of the road network and produces erroneous visualization results of event locations. This software bug causes serious problems for applications in which accurate location information is critical for emergency responses, such as traffic accidents. This paper aims to address this problem and proposes an improved method that utilizes all relevant information of traffic accidents, namely, route number, direction, and mile post, and extracts correct event locations for accurate traffic accident visualization and analysis. The proposed method generates a new shape file for traffic accidents and displays them on top of the existing road network in ArcGIS. Visualization of traffic accidents along Hampton Roads Bridge Tunnel is included to demonstrate the effectiveness of the proposed method.

  18. Intercomparison of aerosol instruments: number concentration

    SciTech Connect

    Knutson, E O; Sinclair, D; Tu, K W; Hinchliffe, L; Franklin, H

    1982-05-01

    An intercomparison of aerosol instruments conducted February 23-27, 1981, at the Environmental Measurements Laboratory (EML) focused on five instruments: the Pollak and TSI condensation nucleus counters; the Active Scattering Aerosol Spectrometer (ASAS-X); and two aerosol electrometers. Test aerosols of sodium chloride and ammonium fluorescein generated by nebulization/electrostatic classification were used to obtain 195 lines of comparison data. Concentrations measured by the ASAS-X and the TSI aerosol electrometer averaged respectively 1.388 and 1.581 times that measured by the Pollak. These ratios were very stable during the week and there was little effect of particle size or material. Most other comparisons were equally stable. However, a review of past work at EML and elsewhere led to the disturbing conclusion that these ratios may change from year to year, or from season to season. A filter sample was taken from microscopy, concurrent with readings from the ASAS-X and the TSI condensation nucleus counters. In this sample, the two instruments differed by 20%. Within its 20% uncertainty, the filter result matched both the TSI and ASAS-X readings.

  19. Atmospheric model intercomparison project: Monsoon simulations

    SciTech Connect

    Sperber, K.R.; Palmer, T.N.

    1994-06-01

    The simulation of monsoons, in particular the Indian summer monsoon, has proven to be a critical test of a general circulation model`s ability to simulate tropical climate and variability. The Monsoon Numerical Experimentation Group has begun to address questions regarding the predictability of monsoon extremes, in particular conditions associated with El Nino and La Nina conditions that tend to be associated with drought and flood conditions over the Indian subcontinent, through a series of seasonal integrations using analyzed initial conditions from successive days in 1987 and 1988. In this paper the authors present an analysis of simulations associated with the Atmospheric Model Intercomparison Project (AMIP), a coordinated effort to simulate the 1979--1988 decade using standardized boundary conditions with approximately 30 atmospheric general circulation models. The 13 models analyzed to date are listed. Using monthly mean data from these simulations they have calculated indices of precipitation and wind shear in an effort to access the performance of the models over the course of the AMIP decade.

  20. Hanford Personnel Dosimeter supporting studies FY-1980. [Lead abstract

    SciTech Connect

    Endres, G.W.R.; Cummings, F.M.; Aldrich, J.M.; Thorson, M.R.; Kathren, R.L.

    1981-02-01

    Separate abstracts were prepared for the 10 sections of this report which describe fundamental characteristics of the Hanford multipurpose personnel dosimeter (HMPD). Abstracts were not prepared for Appendix A and Appendix B which deal with calculated standard deviations for 100 mrem mixed field exposures and detailed calculations of standard deviations, respectively. (KRM)

  1. Development of an improved fingertip dosimeter for beta radiation

    SciTech Connect

    Couch, N.W.

    1986-01-01

    The dosimeter employs a multi-element, multi-filter concept by stacking four 0.13 mm LiF-teflon TLD's to form the beta detector element. The entire dosimeter is approximately 1 mm thick, flexible, and rugged enough for field use without interference with the manual dexterity of the user. The fingertip dosimeter provides data for determining the beta energy of each exposure. The beta energy can be used to determine the TLD response factor for correcting the TLD output to beta dose in mrad. The data can be used to reconstruct the beta depth dose curve due to single beta or mixed beta exposures. For mixed beta/gamma exposures, the addition of a gamma measuring element would provide data for separating the gamma component for the beta component. The depth dose curve can be used to calculate the beta doses in tissue at 7 mg/cm/sup 2/, for legal reporting purposes, or at any other desired depth within the range of the beta radiation. The fingertip dosimeter was used to monitor extremity beta doses for research lab personnel. The results showed higher fingertip beta doses than had previously been expected. The average monthly beta dose was shown to be approximately 0.5 rad/mo.

  2. Thin thermoluminescent dosimeter and method of making same

    DOEpatents

    Simons, Gale G.; DeBey, Timothy M.

    1987-01-01

    An improved thermoluminescent ionizing radiation dosimeter of solid, extremely thin construction for more accurate low energy beta dosimetry is provided, along with a method of fabricating the dosimeter. In preferred forms, the dosimeter is a composite including a backing support (which may be tissue equivalent) and a self-sustaining body of solid thermoluminescent material such as LiF having a thickness of less than about 0.25 millimeters and a volume of at least about 0.0125 mm.sup.3. In preferred fabrication procedures, an initially thick (e.g., 0.89 millimeters) TLD body is wet sanded using 600 grit or less sandpaper to a thickness of less than about 0.25 millimeters, followed by adhesively attaching the sanded body to an appropriate backing. The sanding procedure permits routine production of extremely thin (about 0.05 millimeters) TLD bodies, and moreover serves to significantly reduce non-radiation-induced thermoluminescence. The composite dosimeters are rugged in use and can be subjected to annealing temperatures for increased accuracy.

  3. Characterization of a reusable PRESAGE® 3D dosimeter

    NASA Astrophysics Data System (ADS)

    Juang, T.; Adamovics, J.; Oldham, M.

    2015-01-01

    This study investigates a reusable PRESAGE® 3D dosimeter (Presage-RU), which would improve cost-effectiveness and facilitate wider implementation of comprehensive, high resolution 3D dosimetry. Small (1x1x4.5 cm) and large (8 cm diameter, 4.5 cm length) sample dosimeters were irradiated multiple times to characterize dose response (i.e. radiation-induced change in optical density (ΔOD)), optical clearing rate, and dose distribution stability. Presage- RU exhibited an initial dose response sensitivity of 0.0119 ΔOD/(cm-Gy), a reduction in response with subsequent irradiations, and a small, permanent ΔOD (~1-6% of initial signal) following each irradiation. Dosimeters optically cleared at an exponential rate (average T1/2 = 24.8±3.6 h), and were effectively cleared after ~5-8 days. 3D gamma analysis (3%/3mm, 10% dose threshold) of a 4-field box plan applied to the large dosimeter showed good agreement following initial irradiation (96.6% passing), but a reduction in passing rate (89.1% passing) with subsequent irradiation. Further study is warranted to fully assess and quantify the performance of Presage-RU for repeat irradiations.

  4. Two methods for examining angular response of personnel dosimeters

    SciTech Connect

    Plato, P.; Leib, R.; Miklos, J.

    1988-06-01

    The American National Standard ANSI N13.11-1983 is used to test the accuracy (bias plus precision) of dosimetry processors as part of the dosimetry accreditation program of the National Voluntary Laboratory Accreditation Program (NVLAP). Section 3.8 of the ANSI N13.11-1983 standard requires that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. The NVLAP accreditation program excluded Section 3.8, and thus no angular response data have been generated in an organized fashion. The objective of this project is to examine the feasibility of two alternative methods to test the angular response of personnel dosimeters. The first alternative involves static irradiations with the dosimeters at fixed angles to a radiation source. The second alternative involves dynamic irradiations with the dosimeters mounted on a rotating phantom. A Panasonic UD-802 personnel dosimetry system** was used to generate data to examine both alternatives. The results lead to two major conclusions. Firstly, Section 3.8 of the ANSI N13.11-1983 standard should be amended to require a pass/fail test for angular response. Secondly, a comparison between angular response data generated with a fixed or a rotating phantom shows that the rotating phantom is the more cost-effective method.

  5. Portable battery-free charger for radiation dosimeters

    DOEpatents

    Manning, Frank W.

    1984-01-01

    This invention is a novel portable charger for dosimeters of the electrometer type. The charger does not require batteries or piezoelectric crystals and is of rugged construction. In a preferred embodiment, the charge includes a housing which carries means for mounting a dosimeter to be charged. The housing also includes contact means for impressing a charging voltage across the mounted dosimeter. Also, the housing carries a trigger for operating a charging system mounted in the housing. The charging system includes a magnetic loop including a permanent magnet for establishing a magnetic field through the loop. A segment of the loop is coupled to the trigger for movement thereby to positions opening and closing the loop. A coil inductively coupled with the loop generates coil-generated voltage pulses when the trigger is operated to open and close the loop. The charging system includes an electrical circuit for impressing voltage pulses from the coil across a capacitor for integrating the pulses and applying the resulting integrated voltage across the above-mentioned contact means for charging the dosimeter.

  6. Influence of preparation and calibration method of PAGAT dosimeter on TSE MR readout results

    NASA Astrophysics Data System (ADS)

    Vávrů, K.; Dvořák, P.; Tintěra, J.; Spěváček, V.

    2013-06-01

    In this study PAGAT dosimeter evaluation by TSE sequence was tested. PAGAT dosimeter preparation procedure was modified to increase the dosimeter sensitivity. Because THPC reacts with gelatin, adding THPC to monomer solution prior to dissolved gelatine helps exploit THPC as an antioxidant. Turbo spin echo sequence enables to evaluate gel dosimeter with 3D equidistant resolution in a reasonable scanning time. Glass walls of the phantom cause problems both by computing inaccuracies and MR imaging artefacts. The inner dosimeter volume is not affected by these inaccuracies and should be used for radiotherapy plan verification.

  7. Deconnable self-reading pocket dosimeter containment with self-contained light

    SciTech Connect

    Stevens, R.L.; Arnold, G.N.; McBride, R.G.

    1995-12-31

    A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.

  8. Deconnable self-reading pocket dosimeter containment with self-contained light

    DOEpatents

    Stevens, Robyn L.; Arnold, Greg N.; McBride, Ryan G.

    1996-01-01

    A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.

  9. RESULTS FROM THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    A North American Mercury Model Intercomparison Study (NAMMIS) has been conducted to build upon the findings from previous mercury model intercomparison in Europe. In the absence of mercury measurement networks sufficient for model evaluation, model developers continue to rely on...

  10. Section 9.1 new dosimeters. New dosimetry systems

    NASA Astrophysics Data System (ADS)

    McLaughlin, William L.

    During the past two years there have been significant advances in several forms of radiation measurement systems for radiation processing, covering dose ranges of 1-10 6 Gy. Calorimeters as reference standards for both ionizing photon and electron fields have become well-established. In addition to the older ceric-cerous dosimetry solution analyzed potentiometrically, new liquid-phase dosimeters include those analyzed by spectrophotometry, e.g., improved forms of acidic aqueous solutions of K-Ag dichromate and organic radiochromic dye solutions. It has recently been demonstrated that by using certain refined sugars, e.g., D-(-) ribose, optical rotation response in aqueous solutions can be enhanced for dosimetry at doses > 10 4 Gy. There has been expanded development, use, and formulation (rods, tablets, and thin films) of the amino acid, alanine, as a solid-phase dosimeter analyzed by either ESR spectrometry or by glutamine or alanine spectrophotometry of complexes with ferric ion in the presence of a sulfonphthalein dye (xylenol orange). New commercial types of radiochromic plastic dosimeters, e.g., GafChromic TM, Riso B3 TM, GAMMACHROME YR TM, Radix TM, and Gammex TM, have been introduced and applied in practice. Improvements and broader use of optical waveguide dosimeters, e.g., Opti-Chromic TM, have also been reported, especially in food irradiation applications. Several novel dyed plastic dosimeters are available in large quantities and they lose color due to irradiation. An example is a dyed cellulosic thin film (ATC type DY-42 TM) which can be measured spectrophotometrically or densitometrically up to doses as high as 10 6 Gy.

  11. VALIDATION OF HANFORD PERSONNEL AND EXTREMITY DOSIMETERS IN PLUTONIUM ENVIRONMENTS

    SciTech Connect

    Scherpelz, Robert I.; Fix, John J.; Rathbone, Bruce A.

    2000-02-10

    A study was performed in the Plutonium Finishing Plant to assess the performance of Hanford personnel neutron dosimetry. The study was assessed whole body dosimetry and extremity dosimetry performance. For both parts of the study, the TEPC was used as the principle instrument for characterizing workplace neutron fields. In the whole body study, 12.7-cm-diameter TEPCs were used in ten different locations in the facility. TLD and TED personnel dosimeters were exposed on a water-filled phantom to enable a comparison of TEPC and dosimeter response. In the extremity study, 1.27-cm-diameter TEPCs were exposed inside the fingers of a gloveboxe glove. Extremity dosimeters were wrapped around the TEPCs. The glove was then exposed to six different cans of plutonium, simulating the exposure that a worker's fingers would receive in a glovebox. The comparison of TEPC-measured neutron dose equivalent to TLD-measured gamma dose equivalent provided neutron-to-gamma ratios that can be used to estimate the neutron dose equivalent received by a worker's finger based on the gamma readings of an extremity dosimeter. The study also utilized a Snoopy and detectors based on bubble technology for assessing neutron exposures, providing a comparison of the effectiveness of these instruments for workplace monitoring. The study concludes that the TLD component of the HCND performs adequately overall, with a positive bias of 30%, but exhibits excessive variability in individual results due to instabilities in the algorithm. The TED response was less variable but only 20% of the TEPC reference dose on average because of the low neutron energies involved. The neutron response of the HSD was more variable than the TLD component of the HCND and biased high by a factor of 8 overall due to its calibration to unmoderated 252Cf. The study recommends further work to correct instabilities in the HCND algorithm and to explore the potential shown by the bubble-based dosimeters.

  12. Laser accidents: Being Prepared

    SciTech Connect

    Barat, K

    2003-01-24

    The goal of the Laser Safety Officer and any laser safety program is to prevent a laser accident from occurring, in particular an injury to a person's eyes. Most laser safety courses talk about laser accidents, causes, and types of injury. The purpose of this presentation is to present a plan for safety offices and users to follow in case of accident or injury from laser radiation.

  13. Accident mortality among children

    PubMed Central

    Swaroop, S.; Albrecht, R. M.; Grab, B.

    1956-01-01

    The authors present statistics on mortality from accidents, with special reference to those relating to the age-group 1-19 years. For a number of countries figures are given for the proportional mortality from accidents (the number of accident deaths expressed as a percentage of the number of deaths from all causes) and for the specific death-rates, per 100 000 population, from all causes of death, from selected causes, from all causes of accidents, and from various types of accident. From these figures it appears that, in most countries, accidents are becoming relatively increasingly prominent as a cause of death in childhood, primarily because of the conquest of other causes of death—such as infectious and parasitic diseases, which formerly took a heavy toll of children and adolescents—but also to some extent because the death-rate from motor-vehicle accidents is rising and cancelling out the reduction in the rate for other causes of accidental death. In the authors' opinion, further epidemiological investigations into accident causation are required for the purpose of devising quicker and more effective methods of accident prevention. PMID:13383361

  14. Intercomparison of Hydrologic Processes in AMIP GCMs.

    NASA Astrophysics Data System (ADS)

    Lau, K.-M.; Sud, Y.; Kim, J. H.

    1996-10-01

    Results of an intercomparison study under the Atmospheric Model Intercomparison Project (AMIP) to assess the abilities of 29 global climate models (GCMS) in simulating various aspects of regional and hydrologic processes in response to observed sea surface temperature and sea ice boundary forcings are presented. The authors find that the models generally portray an earthlike climate to approximately 10%-20% of the global land surface temperature (=14.8°C) and global precipitation (=2.3 mm day1). While a majority of the models have a reasonable global water budget, about a quarter of the models show significant errors in the total global water balance.While the model frequency distributions of heavy precipitation associated with deep convection are in reasonable agreement with observations, a systematic underestimate of the frequency of occurrence of light precipitation events (< 1 mm day1) is present in almost all the AMIP models, especially over continental desert regions and over tropical and subtropical oceanic regions contiguous to the west coasts of continents where low-level stratocumulus clouds tend to occur. This discrepancy is presumably related to the crude treatment of moist processes, especially those related to low clouds and nonconvective precipitation in the models. Another common problem in the global rainfall distribution is the presence of spectral rain or spurious gridpoint-scale heavy rain. The artificial anchoring of rainfall to topographic features in the Maritime Continent appears to be a generic problem in many GCMs. Models differ substantially in the magnitude of the rainfall amount over the eastern Pacific ITCZ for all seasons. The simulated boreal summer rainfall distributions have large variability over the Indian subcontinent and the Bay of Bengal. The northward migration of the monsoon convective zones are not well simulated. In particular, the Fast Asian monsoon rainband over the subtropical western Pacific is ill-defined or absent

  15. Tenth ORNL Personnel Dosimetry Intercomparison Study

    SciTech Connect

    Swaja, R.E.; Chou, T.L.; Sims, C.S.; Greene, R.T.

    1985-03-01

    The Tenth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory during April 9-11, 1984. Dosemeter badges from 31 participating organizations were mounted on 40cm Lucite phantoms and exposed to a range of dose equivalents which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor served as the only source of radiation for eight of the ten irradiations which included a low (approx. 0.50 mSv) and high (approx. 10.00 mSv) neutron dose equivalent run for each of four shield conditions. Two irradiations were also conducted for which concrete- and Lucite-shield reactor irradiations were gamma-enhanced using a /sup 137/Cs source. Results indicated that some participants had difficulty obtaining measurable indication of neutron and gamma exposures at dose equivalents less than about 0.50 mSv and 0.20 mSv, respectively. Albedo dosemeters provided the best overall accuracy and precision for the neutron measurements. Direct interaction TLD systems showed significant variation in accuracy with incident spectrum, and threshold neutron dosemeters (film and recoil track) underestimated reference values by more than 50%. Gamma dose equivalents estimated in the mixed fields were higher than reference values with TL gamma dosemeters generally yielding more accurate results than film. Under the conditions of this study in which participants had information concerning exposure conditions and radiation field characteristics prior to dosemeter evaluation, only slightly more than half of all reported results met regulatory standards for neutron and gamma accuracy. 19 refs., 2 figs., 29 tabs.

  16. Ozone Differential Absorption Lidar Algorithm Intercomparison

    NASA Astrophysics Data System (ADS)

    Godin, Sophie; Carswell, Allen I.; Donovan, David P.; Claude, Hans; Steinbrecht, Wolfgang; McDermid, I. Stuart; McGee, Thomas J.; Gross, Michael R.; Nakane, Hideaki; Swart, Daan P. J.; Bergwerff, Hans B.; Uchino, Osamu; von der Gathen, Peter; Neuber, Roland

    1999-10-01

    An intercomparison of ozone differential absorption lidar algorithms was performed in 1996 within the framework of the Network for the Detection of Stratospheric Changes (NDSC) lidar working group. The objective of this research was mainly to test the differentiating techniques used by the various lidar teams involved in the NDSC for the calculation of the ozone number density from the lidar signals. The exercise consisted of processing synthetic lidar signals computed from simple Rayleigh scattering and three initial ozone profiles. Two of these profiles contained perturbations in the low and the high stratosphere to test the vertical resolution of the various algorithms. For the unperturbed profiles the results of the simulations show the correct behavior of the lidar processing methods in the low and the middle stratosphere with biases of less than 1% with respect to the initial profile to as high as 30 km in most cases. In the upper stratosphere, significant biases reaching 10% at 45 km for most of the algorithms are obtained. This bias is due to the decrease in the signal-to-noise ratio with altitude, which makes it necessary to increase the number of points of the derivative low-pass filter used for data processing. As a consequence the response of the various retrieval algorithms to perturbations in the ozone profile is much better in the lower stratosphere than in the higher range. These results show the necessity of limiting the vertical smoothing in the ozone lidar retrieval algorithm and questions the ability of current lidar systems to detect long-term ozone trends above 40 km. Otherwise the simulations show in general a correct estimation of the ozone profile random error and, as shown by the tests involving the perturbed ozone profiles, some inconsistency in the estimation of the vertical resolution among the lidar teams involved in this experiment.

  17. Intercomparison Between Microwave Radiometer and Radiosonding Data

    NASA Astrophysics Data System (ADS)

    Toanca, Florica; Stefan, Sabina

    2014-05-01

    The aim of this study is to compare relative humidity and temperature vertical profiles measured by ground based Microwave Radiometer (MWR) RPG HATPRO installed at the Romanian Atmospheric Observatory (Magurele, 44.35 N, 26.03 E) and by radio-sounding (RS) (Baneasa, 44.30 N, 26.04 E) provided by National Meteorological Administration. MWR uses passive microwave detection in the 22.335 to 31.4 GHz and 51to 58 GHz bands to obtain the vertical profiles of temperature and relative humidity up to 10km with a temporal resolution of several minutes. The reliability of atmospheric temperature and relative humidity profiles retrieved continuously by the MWR for the winter and summer of year 2013 was studied. The study was conducted, comparing the temperature and humidity profiles from the MWR with the ones from the radio soundings at 0:00 a.m. Two datasets of the humidity show a fairly good agreement for the interval between ground and 1.5 km in the January month for winter and up to 2 km in the July month for summer. Above 2 km, for the both seasons, the humidity profiles present in most of the selected cases the same trend evolution. The temperature vertical profiles agreed in 95% of the cases during summer and 85% during winter. It is very important for intercomparison that for both seasons almost all temperature vertical profiles highlight temperature inversions. Two cases have been analyzed in order to find possible explanations for the discrepancies between vertical profiles, focusing on advantages and disadvantages of MWR measurements.

  18. ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study

    NASA Technical Reports Server (NTRS)

    Fridlind, Ann; Ackerman, Andrew; Petch, Jon; Field, Paul; Hill, Adrian; McFarquhar, Greg; Xie, Shaocheng; Zhang, Minghua

    2010-01-01

    Specifications are provided for running a cloud-resolving model (CRM) and submitting results in a standardized format for inclusion in a n intercomparison study and archiving for public access. The simulated case study is based on measurements obtained during the 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) led by the U. S. department of Energy Atmospheric Radiation Measurement (ARM) program. The modeling intercomparison study is based on objectives developed in concert with the Stratospheric Processes And their Role in Climate (SPARC) program and the GEWEX cloud system study (GCSS) program. The Global Energy and Water Cycle Experiment (GEWEX) is a core project of the World Climate Research PRogramme (WCRP).

  19. QUADOS intercomparison: a summary of photon and charged particle problems.

    PubMed

    Gualdrini, G; Agosteo, S; Ménard, S; Price, R A; Chartier, J-L; Grosswendt, B; Kodeli, I; Leuthold, G P; Siebert, B R L; Tagziria, H; Tanner, R J; Terrissol, M; Zankl, M

    2005-01-01

    QUADOS, a Concerted Action of the European Commission, has promoted an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of radiation transport codes. Eight problems were selected for their relevance to the radiation dosimetry community, five of which involved photon and proton transport. This paper focuses on the analysis of the photon and charged particle problems. The neutron problems were presented in a paper at the NEUDOS9 conference. PMID:16381790

  20. Contribution towards statistical intercomparison of general circulation models

    SciTech Connect

    Sengupta, S.; Boyle, J.

    1995-06-01

    The Atmospheric Model Intercomparison Project (AMIP) of the World Climate Research Programme`s Working Group on Numerical Experimentation (WGNE) is an ambitious attempt to comprehensively intercompare atmospheric General Circulation Models (GCMs). The participants in AMIP simulate the global atmosphere for the decade 1979 to 1988 using, a common solar constant and Carbon Dioxide(CO{sub 2}) concentration and a common monthly averaged sea surface temperature (SST) and sea ice data set. In this work we attempt to present a statistical framework to address the difficult task of model intercomparison and verification.

  1. Environmental radioactive intercomparison program and radioactive standards program

    SciTech Connect

    Dilbeck, G.

    1993-12-31

    The Environmental Radioactivity Intercomparison Program described herein provides quality assurance support for laboratories involved in analyzing public drinking water under the Safe Drinking Water Act (SDWA) Regulations, and to the environmental radiation monitoring activities of various agencies. More than 300 federal and state nuclear facilities and private laboratories participate in some phase of the program. This presentation describes the Intercomparison Program studies and matrices involved, summarizes the precision and accuracy requirements of various radioactive analytes, and describes the traceability determinations involved with radioactive calibration standards distributed to the participants. A summary of program participants, sample and report distributions, and additional responsibilities of this program are discussed.

  2. Airline accident response.

    PubMed

    Bettes, Thomas

    2002-01-01

    This article outlines government regulations affecting accident response and offers guidelines for airline contingency plans in the face of major air disasters, such as those encountered on September 11, 2001. The author also touches upon the role of the corporate medical department in accident investigation and victim identification. PMID:11872433

  3. Civil aircraft accident investigation.

    PubMed

    Haines, Daniel

    2013-01-01

    This talk reviews some historic aircraft accidents and some more recent. It reflects on the division of accident causes, considering mechanical failures and aircrew failures, and on aircrew training. Investigation results may lead to improved aircraft design, and to appropriate crew training. PMID:24057309

  4. Anatomy of an Accident.

    ERIC Educational Resources Information Center

    Mobley, Michael

    1984-01-01

    The findings of industrial safety engineers in the areas of accident causation and prevention are wholly applicable to adventure programs. Adventure education instructors can use safety engineering concepts to assess the risk in a particular activity, understand factors that cause accidents, and intervene to minimize injuries and damages if…

  5. Urine Radiobioassay Intercomparison Results From The Intercomparison Studies Program At Oak Ridge National Laboratory

    SciTech Connect

    Bores, Norman; Schultz, Michael K

    2008-01-01

    The Intercomparison Studies Program (ISP) at the Oak Ridge National Laboratory (ORNL, Oak Ridge, TN USA) provides natural-matrix human urine quality-assurance/quality-control (QA/QC) samples to radiobioassay analysis laboratories. Samples are provided to these laboratories as 'single-blind' or 'double-blind' unknowns, spiked with radioactive-solution standards at 'low' levels (e.g., 0-250 mBq {center_dot} kg{sup -1} for alpha-emitters). Participants use the results as a tool for self-evaluation and a measure of performance. In this paper, sample preparation and the results of testing during the years 2000-2004 for the radionuclides natural uranium (U-nat), {sup 238}Pu, {sup 239}Pu, and {sup 241}Am are presented and discussed.

  6. Intercomparison of Global Precipitation Products: The Third Precipitation Intercomparison Project (PIP-3)

    NASA Technical Reports Server (NTRS)

    Adler, Robert F.; Kidd, Christopher; Petty, Grant; Morrissey, Mark; Goodman, H. Michael; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A set of global, monthly rainfall products has been intercompared to understand the quality and utility of the estimates. The products include 25 observational (satellite-based), four model and two climatological products. The results of the intercomparison indicate a very large range (factor of two or three) of values when all products are considered. The range of values is reduced considerably when the set of observational products is limited to those considered quasi-standard. The model products do significantly poorer in the tropics, but are competitive with satellite-based fields in mid-latitudes over land. Over ocean, products are compared to frequency of precipitation from ship observations. The evaluation of the observational products point to merged data products (including rain gauge information) as providing the overall best results.

  7. The high dose response and functional capability of the DT-702/Pd lithium fluoride thermoluminescent dosimeter.

    PubMed

    Lawlor, Tyler M; Talmadge, Molly D; Murray, Mark M; Nelson, Martin E; Mueller, Andrew C; Romanyukha, Alexander A; Fairchild, Gregory R; Grypp, Matthew D; Williams, Anthony S

    2015-05-01

    The United States Navy monitors the dose its radiation workers receive using the DT-702/PD thermoluminescent dosimeter, which consists of the Harshaw 8840 holder and the four-element Harshaw 8841 card. There were two main objectives of this research. In the first objective, the dosimeters were exposed to 100 Gy using electron and x-ray beams and found to respond approximately 30-40% lower than the delivered dose. No significant effect on the under-response was found when dose rate, radiation type, dosimeter position on the phantom, and dosimeter material were varied or when the card was irradiated while enclosed in its holder. Since the current naval policy is to remove from occupational use any thermoluminescent dosimeter with an accumulated deep dose equivalent of 0.05 Sv or greater, the functionality of the dosimeter was also investigated at deep dose equivalents of 0.05, 0.15, and 0.25 Sv using 60Co and 137Cs sources as the second main objective. All dosimeters were annealed following exposure and then exposed to 5.0 mSv from a 90Sr source. In all cases, the dosimeters responded within 3% of the delivered dose, indicating that the dosimeters remained functional as defined by naval dosimetry requirements. However, the anneal time required to clear the thermoluminescent dosimeter's reading was found to increase approximately as the cube root with the delivered dose. PMID:25811149

  8. Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF:Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology.

    PubMed

    Dong, S L; Chu, T C; Lan, G Y; Wu, T H; Lin, Y C; Lee, J S

    2002-12-01

    Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3% at tube potentials from 40Vp to 125kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures. PMID:12406633

  9. [Measurement of the Dose Rate Using Dosimeters in Interventional Radiology and Its Difficulty].

    PubMed

    Yoshida, Hidenori; Takahashi, Chiharu; Narita, Nobuhiro; Mizusawa, Yasuhiko; Sekiya, Masaru; Ohkubo, Masaki

    2016-01-01

    In equipment used for interventional radiology (IVR), automatic exposure control (AEC) is incorporated to obtain the X-ray output suitable for the treatment of targeted lesions. For the AEC, users select a region as the signal sensing region (measuring field, MF) in the flat panel detector; MFs with various sizes and shapes were pre-defined and prepared in the system. The aim of this study was to examine the change of measured dose rate with the selection of MFs, the type of dosimeters (the ionization chamber dosimeter and the semiconductor dosimeter), and the dosimeter placement relative to the direction of X-ray tube (from cathode to anode). The IVR equipment was Allura Xper FD20/10 (Philips Medical Systems), and six kinds of built-in MFs were used. It was found that dose rate measured by the ionization chamber dosimeter showed a variation of -2 mGy/min with the MFs and the ionization chamber dosimeter placement. The dose rate measured by the semiconductor dosimeter showed more variation than the ionization chamber dosimeter. The change of dose rate with the dosimeter placement would be caused by the MF overlapping the dosimeter which would affect the AEC (the X-ray output). Also, the change of dose rate with the dosimeter placement was considered to be related to the heel effect of the X-ray beam. When performing dose rate measurements, we should notice that the selection of MFs, the type of dosimeters, and the dosimeter placement would affect the measured values. PMID:26796935

  10. New sintered thermoluminescent dosimeters for personnel and environmental dosimetry.

    PubMed

    Prokic, M S

    1982-06-01

    We discuss the development of an original method preparing thermoluminescent dosimeters using magnesium borate and calcium sulfate materials activated with rare earths. This method is based upon the effect of sensitized thermoluminescent emission of basic TLD phosphors as well as on the method for producing these in solid form. Our technique resulted in unique TLD's in the form of sintered thermoluminescent dosimeters. For one of these, MgB4O7:RE+, the thermoluminescent response is up to five times more sensitive than non-sensitized magnesium borate thermoluminescent material. The other TLD, CaSO4:RE+, has dosimetric characteristics which stay unchanged and are equivalent with characteristics of the well-known calcium sulfate TLD phosphors. These new types of sintered TLD's are highly promising for personnel and environmental dosimetry. PMID:7107292

  11. A genipin-gelatin gel dosimeter for radiation processing

    NASA Astrophysics Data System (ADS)

    Davies, J. B.; Bosi, S. G.; Baldock, C.

    2012-08-01

    Genipin, a fruit extract from Gardenia jasminoides Ellis, forms cross-links in solutions of gelatin, to form a blue hydrogel that bleaches quantitatively upon irradiation and the colour change can be measured with a spectrophotometer. With the addition of sulphuric acid this dosimeter is sufficiently sensitive for quality assurance of radiotherapy level dosimetry. Without sulphuric acid the gel has a reduced sensitivity and responds linearly with dose between 100 and 1000 Gy, making it potentially useful as a dosimeter for radiation processing applications such as the phytosanitary irradiation treatment of food. We investigated the dose response characteristics of this new formulation and found that the darker gels are more sensitive to dose and have a reduced uncertainty.

  12. Radiochromic leuko dye real time dosimeter, one way optical waveguide

    SciTech Connect

    Kronenberg, S.

    1982-11-15

    This invention relates generally to nuclear radiation dosimetry, and more particularly to a radiochromic leuko dye dosimeter constructed and arranged to measure absorbed radiation doses, such as gamma rays, X-rays and fast neutrons, in real time; viz., as the dose is being delivered. A radiochromic leuko dye dosimeter includes a plastic tube containing a solution of a radiochromic dye which is sensitive to ionizing radiation, one end of the tube being closed by a reflective surface, the opposite end of the tube being closed by a transparent plug to form a one-way optical waveguide. Light enters the tube through the transparent end thereof and is reflected back and exists through the transparent end. The intensity of the existing light is measured to determine radiation induced absorption of the leuko dye.

  13. A new electronic neutron dosimeter (END) for reliable personal dosimetry

    NASA Astrophysics Data System (ADS)

    Ing, H.; Cousins, T.; Andrews, H. R.; Machrafi, R.; Voevodskiy, A.; Kovaltchouk, V.; Clifford, E. T. H.; Robins, M.; Larsson, C.; Hugron, R.; Brown, J.

    2008-04-01

    Tests of existing electronic neutron dosimeters by military and civilian groups have revealed significant performance limitations. To meet the operational requirements of emergency response personnel to a radiological/nuclear incident as well as those in the nuclear industry, a new END has been developed. It is patterned after a unique commercial neutron spectral dosemeter known as the N-probe. It uses a pair of small special scintillators on tiny photomultiplier tubes. Special electronics were designed to minimize power consumption to allow for weeks of operation on a single charge. The size, performance, and data analysis for the END have been designed to meet/exceed international standards for electronic neutron dosimeters. Results obtained with the END prototype are presented.

  14. Laser CT evaluation on normoxic PAGAT gel dosimeter

    NASA Astrophysics Data System (ADS)

    Kumar, D. S.; Samuel, E. J. J.; Watanabe, Y.

    2013-06-01

    Optical computed tomography has been shown to be a potentially useful imaging tool for the radiation therapy physicists. In radiation therapy, researchers have used optical CT for the readout of 3D dosimeters. The purpose of this paper is to describe the initial evaluation of a newly fabricated laser CT scanner for 3D gel dosimetry which works using the first generation principle. A normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When a laser passes through the gel phantom, absorption and scattering of photon take place. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by a sensor. The scanner motion is controlled by a computer program written in Microsoft Visual C++. Reconstruction and data analysis on the irradiated gel phantom is performed by suitable algorithm using Matlab software.

  15. The Coupled Model Intercomparison Project (CMIP).

    NASA Astrophysics Data System (ADS)

    Meehl, Gerald A.; Boer, George J.; Covey, Curt; Latif, Mojib; Stouffer, Ronald J.

    2000-02-01

    The Coupled Model Intercomparison Project (CMIP) was established to study and intercompare climate simulations made with coupled ocean-atmosphere-cryosphere-land GCMs. There are two main phases (CMIP1 and CMIP2), which study, respectively, 1) the ability of models to simulate current climate, and 2) model simulations of climate change due to an idealized change in forcing (a 1% per year CO2 increase). Results from a number of CMIP projects were reported at the first CMIP Workshop held in Melbourne, Australia, in October 1998. Some recent advances in global coupled modeling related to CMIP were also reported. Presentations were based on preliminary unpublished results. Key outcomes from the workshop were that 1) many observed aspects of climate variability are simulated in global coupled models including the North Atlantic oscillation and its linkages to North Atlantic SSTs, El Niño-like events, and monsoon interannual variability; 2) the amplitude of both high- and low-frequency global mean surface temperature variability in many global coupled models is less than that observed, with the former due in part to simulated ENSO in the models being generally weaker than observed, and the latter likely to be at least partially due to the uncertainty in the estimates of past radiative forcing; 3) an El Niño-like pattern in the mean SST response with greater surface warming in the eastern equatorial Pacific than the western equatorial Pacific is found by a number of models in global warming climate change experiments, but other models have a more spatially uniform or even a La Niña-like, response; 4) flux adjustment, by definition, improves the simulation of mean present-day climate over oceans, does not guarantee a drift-free climate, but can produce a stable base state in some models to enable very long term (1000 yr and longer) integrations-in these models it does not appear to have a major effect on model processes or model responses to increasing CO2; and 5) recent

  16. Low-cost commercial glass beads as dosimeters in radiotherapy

    NASA Astrophysics Data System (ADS)

    Jafari, S. M.; Bradley, D. A.; Gouldstone, C. A.; Sharpe, P. H. G.; Alalawi, A.; Jordan, T. J.; Clark, C. H.; Nisbet, A.; Spyrou, N. M.

    2014-04-01

    Recent developments in advanced radiotherapy techniques using small field photon beams, require small detectors to determine the delivered dose in steep dose gradient fields. Commercially available glass jewellery beads exhibit thermoluminescent properties and have the potential to be used as dosimeters in radiotherapy due to their small size (<5 mm), low cost, reusability and inert nature. This study investigated the dosimetric characteristics of glass beads. The beads were irradiated by 6 MV photons using a medical linear-accelerator and 60Co gamma rays over doses ranging from 1 to 2500 cGy. A thermoluminescence (TL) system and an electron paramagnetic resonance (EPR) system were employed for read out. Both the TL and EPR studies demonstrated a radiation-induced signal, the sensitivity of which varied with bead colour. White coloured beads proved to be the most sensitive for both systems. The smallest and therefore least sensitive bead sizes allowed measurement of doses of 1 cGy using the TL system while that for the EPR system was approximately 1000 cGy. The fading rate was found to be 10% 30 days after irradiation with both readout systems. The dose response is linear with measured dose over the dose range 1 to 2500 cGy, with an R2 correlation coefficient of greater than 0.999. The batch-to-batch reproducibility of a set of dosimeters after a single irradiation was found to be 3% (1 SD). The reproducibility of individual dosimeters was found to be 1.7%. No measurable angular dependence was found (results agreed within 1%). Dose rate response was found to agree within 1% for dose rates of 100 to 600 cGy/min. These results demonstrate the potential use of glass beads as TL dosimeters over the dose range commonly applied in radiotherapy.

  17. An optical dosimeter for monitoring heavy metal ions in water

    NASA Astrophysics Data System (ADS)

    Mignani, Anna G.; Regan, Fiona; Leamy, D.; Mencaglia, A. A.; Ciaccheri, L.

    2005-05-01

    This work presents an optochemical dosimeter for determining and discriminating nickel, copper, and cobalt ions in water that can be used as an early warning system for water pollution. An inexpensive fiber optic spectrophotometer monitors the sensor's spectral behavior under exposure to water solutions of heavy metal ions in the 1-10 mg/l concentration range. The Principal Component Analysis (PCA) method quantitatively determines the heavy metals and discriminates their type and combination.

  18. Method for preparing dosimeter for measuring skin dose

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1982-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with neutron-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  19. Dosimeter for measuring skin dose and more deeply penetrating radiation

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1981-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with netruon-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  20. Response of ionization chamber based pocket dosimeter to beta radiation.

    PubMed

    Kumar, Munish; Gupta, Anil; Pradhan, S M; Bakshi, A K; Chougaonkar, M P; Babu, D A R

    2013-12-01

    Quantitative estimate of the response of ionization chamber based pocket dosimeters (DRDs) to various beta sources was performed. It has been established that the ionization chamber based pocket dosimeters do not respond to beta particles having energy (Emax)<1 MeV and same was verified using (147)Pm, (85)Kr and (204)Tl beta sources. However, for beta particles having energy >1 MeV, the DRDs exhibit measureable response and the values are ~8%, ~14% and ~27% per mSv for natural uranium, (90)Sr/(90)Y and (106)Ru/(106)Rh beta sources respectively. As the energy of the beta particles increases, the response also increases. The response of DRDs to beta particles having energy>1 MeV arises due to the fact that the thickness of the chamber walls is less than the maximum range of beta particles. This may also be one of the reasons for disparity between doses measured with passive/legal dosimeters (TLDs) and DRDs in those situations in which radiation workers are exposed to mixed field of gamma photons and beta particles especially at uranium processing plants, nuclear (power and research) reactors, waste management facilities and fuel reprocessing plants etc. The paper provides the reason (technical) for disparity between the doses recorded by TLDs and DRDs in mixed field of photons and beta particles. PMID:23978508

  1. Radiation measured for MATROSHKA-1 experiment with passive dosimeters

    NASA Astrophysics Data System (ADS)

    Zhou, D.; Semones, E.; O'Sullivan, D.; Zapp, N.; Weyland, M.; Reitz, G.; Berger, T.; Benton, E. R.

    2010-01-01

    The radiation field in low Earth orbit (LEO) and deep space is complicated. The radiation impact on astronauts depends strongly on the particles' linear energy transfer (LET) and is dominated by high LET radiation. Radiation risk is a key concern for human space flight and can be estimated with radiation LET spectra measured for the different organs of an astronaut phantom. At present the best passive personal dosimeters used for astronauts are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) for low LET and CR-39 plastic nuclear track detectors (PNTDs) for high LET. CR-39 PNTDs, TLDs and OSLDs were used for the MATROSHKA-1 experiment to measure radiation experienced by astronauts outside the international space station (ISS). LET spectra and radiation field quantities (differential and integral fluence, absorbed dose and dose equivalent) were measured for the different organs and skin locations of the MAROSHKA phantom using CR-39 PNTDs and TLDs. The spectra and results can be used to determine the radiation quantities for astronaut's extra vehicular activity (EVA) and for the further in-depth study of the radiation risk for astronauts. Sensitivity fading of CR-39 detectors was observed for the MATROSHKA experiment and a practical method was developed to correct it. This paper presents the radiation LET spectra measured with CR-39 PNTDs and the total radiation quantities combined from results measured with CR-39 PNTDs and TLDs.

  2. NOTE: Visible absorption spectra of radiation exposed SIRAD dosimeters

    NASA Astrophysics Data System (ADS)

    Butson, Martin J.; Cheung, Tsang; Yu, Peter K. N.

    2006-12-01

    SIRAD badge dosimeters are a new type of personal dosimeter designed to measure radiation exposure up to 200 R and give a visual qualitative measurement of exposure. This is performed using the active dosimeter window, which contains a radiochromic material amalgamated in the badge assembly. When irradiated, the badges active window turns blue, which can be matched against the given colour chart for a qualitative assessment of the exposure received. Measurements have been performed to analyse the absorption spectra of the active window, and results show that the window automatically turns a blue colour upon irradiation and produces two peaks in the absorption spectra located at 617 nm and 567 nm. When analysed with a common computer desktop scanner, the optical density response of the film to radiation exposure is non-linear but reproducible. The net OD of the film was 0.21 at 50 R exposure and 0.31 at 200 R exposure when irradiated with a 6 MV x-ray energy beam. When compared to the calibration colour strips at 6 MV x-ray energy the film's OD response matches relatively well within 3.5%. An approximate 8% reduction in measured OD to exposure was seen for 250 kVp x-rays compared to 6 MV x-rays. The film provides an adequate measurement and visually qualitative assessment of radiation exposure for levels in the range of 0 to 200 R.

  3. Real-time dosimeter targeted to nuclear applications

    NASA Astrophysics Data System (ADS)

    Correia, Alexandre; Rosa, Carla C.; Santos, Pedro M. P.; Falcão, António N.; Lorentz, Katharina

    2014-08-01

    An intrinsic fiber optic dosimeter (FOD) targeted to nuclear applications is presented. The proposed real-time dosimeter provides dose information based on the historic record over time of the effects of ionizing radiation on single- and multimode pure silica fibers, and also on PMMA plastic fibers. The effect of 60Co gamma irradiation on optical links based on silica and plastic fibers were assessed, considering thermal environment effects over a wide range of variation of the operating parameters. Cerenkov radiation and radiation-induced absorption effects were in focus. The corresponding distortion and spectral transmission degradation were evaluated over wide range of the operating parameters. Radiation induced attenuation (RIA) has shown a spectral band dependent behaviour up to 840 Gy dose levels. The performance of different fibers was assessed against the performance of non-irradiated fibers. From the measurements of dose rate and total dose imparted by ionizing radiation in the fibers we verified that fibers with radiation resistance issues showed wavelength-dependent radiation sensitivity increasing with dose rate. Upon evaluation of correlations between the total dose, the induced loss at various dose rates and different wavelengths, it was concluded that intrinsic fiber dosimeters can be used for dose rates in the range 4 - 28 Gy/min., typical of severe radiation environments.

  4. Persistence of airline accidents.

    PubMed

    Barros, Carlos Pestana; Faria, Joao Ricardo; Gil-Alana, Luis Alberiko

    2010-10-01

    This paper expands on air travel accident research by examining the relationship between air travel accidents and airline traffic or volume in the period from 1927-2006. The theoretical model is based on a representative airline company that aims to maximise its profits, and it utilises a fractional integration approach in order to determine whether there is a persistent pattern over time with respect to air accidents and air traffic. Furthermore, the paper analyses how airline accidents are related to traffic using a fractional cointegration approach. It finds that airline accidents are persistent and that a (non-stationary) fractional cointegration relationship exists between total airline accidents and airline passengers, airline miles and airline revenues, with shocks that affect the long-run equilibrium disappearing in the very long term. Moreover, this relation is negative, which might be due to the fact that air travel is becoming safer and there is greater competition in the airline industry. Policy implications are derived for countering accident events, based on competition and regulation. PMID:20618386

  5. Sleep related vehicle accidents.

    PubMed Central

    Horne, J. A.; Reyner, L. A.

    1995-01-01

    OBJECTIVES--To assess the incidence, time of day, and driver morbidity associated with vehicle accidents where the most likely cause was the driver falling asleep at the wheel. DESIGN--Two surveys were undertaken, in southwest England and the midlands, by using police databases or on the spot interviews. SUBJECTS--Drivers involved in 679 sleep related vehicle accidents. RESULTS--Of all vehicle accidents to which the police were summoned, sleep related vehicle accidents comprised 16% on major roads in southwest England, and over 20% on midland motorways. During the 24 hour period there were three major peaks: at around 0200, 0600, and 1600. About half these drivers were men under 30 years; few such accidents involved women. CONCLUSIONS--Sleep related vehicle accidents are largely dependent on the time of day and account for a considerable proportion of vehicle accidents, especially those on motorways and other monotonous roads. As there are no norms for the United Kingdom on road use by age and sex for time of day with which to compare these data, we cannot determine what the hourly exposure v risk factors are for these subgroups. The findings are in close agreement with those from other countries. PMID:7888930

  6. THE NORTH AMERICAN MERCURY MODEL INTER-COMPARISON STUDY (NAMMIS)

    EPA Science Inventory

    This paper describes the North American Mercury Model Inter-comparison Study (NAMMIS). The NAMMIS is an effort to apply atmospheric Hg models in a tightly constrained testing environment with a focus on North America. With each model using the same input data sets for initial co...

  7. Evaluation of the annual Canadian biodosimetry network intercomparisons

    PubMed Central

    Wilkins, Ruth C.; Beaton-Green, Lindsay A.; Lachapelle, Sylvie; Kutzner, Barbara C.; Ferrarotto, Catherine; Chauhan, Vinita; Marro, Leonora; Livingston, Gordon K.; Boulay Greene, Hillary; Flegal, Farrah N.

    2015-01-01

    Abstract Purpose: To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response. Materials and methods: Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Intercomparisons were performed over a six-year period and comprised of the shipment of 10–12 irradiated, blinded blood samples for analysis by each of the participating laboratories. Dose estimates were determined by each laboratory using the dicentric chromosome assay (conventional and QuickScan scoring) and where possible the cytokinesis block micronucleus (CBMN) assay. Dose estimates were returned to the lead laboratory for evaluation and comparison. Results: Individual laboratories performed comparably from year to year with only slight fluctuations in performance. Dose estimates using the dicentric chromosome assay were accurate about 80% of the time and the QuickScan method for scoring the dicentric chromosome assay was proven to reduce the time of analysis without having a significant effect on the dose estimates. Although analysis with the CBMN assay was comparable to QuickScan scoring with respect to speed, the accuracy of the dose estimates was greatly reduced. Conclusions: Annual intercomparisons are necessary to maintain a network of laboratories for emergency response biodosimetry as they evoke confidence in their capabilities. PMID:25670072

  8. PM 2.5 ORGANIC SPECIATION INTERCOMPARISON RESULTS

    EPA Science Inventory

    This abstract describes a poster on results to a laboratory intercomparison of organic aerosol speciation analysis to be presented at the 2006 International Aerosol Conference sponsored by the American Association for Aerosol Research in St. Paul, Minnesota on September 10-15. T...

  9. Low-cost solar array project: Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: Radiometer standards

    NASA Technical Reports Server (NTRS)

    Estey, R. S.; Seaman, C. H.

    1981-01-01

    Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

  10. Results of the NY-Alesund ozone measurements intercomparison NAOMI

    NASA Technical Reports Server (NTRS)

    Steinbrecht, W.; Gross, M.; McGee, T.; Neuber, R.; Gathen, P. V. D.; Wahl, P.; Klein, U.; Langer, J.

    1998-01-01

    Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

  11. The Assessment of Effective Dose Equivalent Using Personnel Dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Xie

    From January 1994, U.S. nuclear plants must develop a technically rigorous approach for determining the effective dose equivalent for their work forces. This dissertation explains concepts associated with effective dose equivalent and describes how to assess effective dose equivalent by using conventional personnel dosimetry measurements. A Monte Carlo computer code, MCNP, was used to calculate photon transport through a model of the human body. Published mathematical phantoms of the human adult male and female were used to simulate irradiation from a variety of external radiation sources in order to calculate organ and tissue doses, as well as effective dose equivalent using weighting factors from ICRP Publication 26. The radiation sources considered were broad parallel photon beams incident on the body from 91 different angles and isotropic point sources located at 234 different locations in contact with or near the body. Monoenergetic photons of 0.08, 0.3, and 1.0 MeV were considered for both sources. Personnel dosimeters were simulated on the surface of the body and exposed to with the same sources. From these data, the influence of dosimeter position on dosimeter response was investigated. Different algorithms for assessing effective dose equivalent from personnel dosimeter responses were proposed and evaluated. The results indicate that the current single-badge approach is satisfactory for most common exposure situations encountered in nuclear plants, but additional conversion factors may be used when more accurate results become desirable. For uncommon exposures involving source situated at the back of the body or source located overhead, the current approach of using multi-badges and assigning the highest dose is overly conservative and unnecessarily expensive. For these uncommon exposures, a new algorithm, based on two dosimeters, one on the front of the body and another one on the back of the body, has been shown to yield conservative assessment of

  12. A basic study of some normoxic polymer gel dosimeters.

    PubMed

    De Deene, Y; Hurley, C; Venning, A; Vergote, K; Mather, M; Healy, B J; Baldock, C

    2002-10-01

    Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical

  13. Investigation of radiological properties and water equivalency of PRESAGE dosimeters

    SciTech Connect

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Adamovics, John; Bosi, Stephen; Kim, Jung-Ha; Baldock, Clive

    2011-04-15

    Purpose: PRESAGE is a dosimeter made of polyurethane, which is suitable for 3D dosimetry in modern radiation treatment techniques. Since an ideal dosimeter is radiologically water equivalent, the authors investigated water equivalency and the radiological properties of three different PRESAGE formulations that differ primarily in their elemental compositions. Two of the formulations are new and have lower halogen content than the original formulation. Methods: The radiological water equivalence was assessed by comparing the densities, interaction probabilities, and radiation dosimetry properties of the three different PRESAGE formulations to the corresponding values for water. The relative depth doses were calculated using Monte Carlo methods for 50, 100, 200, and 350 kVp and 6 MV x-ray beams. Results: The mass densities of the three PRESAGE formulations varied from 5.3% higher than that of water to as much as 10% higher than that of water for the original formulation. The probability of photoelectric absorption in the three different PRESAGE formulations varied from 2.2 times greater than that of water for the new formulations to 3.5 times greater than that of water for the original formulation. The mass attenuation coefficient for the three formulations is 12%-50% higher than the value for water. These differences occur over an energy range (10-100 keV) in which the photoelectric effect is the dominant interaction. The collision mass stopping powers of the relatively lower halogen-containing PRESAGE formulations also exhibit marginally better water equivalency than the original higher halogen-containing PRESAGE formulation. Furthermore, the depth dose curves for the lower halogen-containing PRESAGE formulations are slightly closer to that of water for a 6 MV beam. In the kilovoltage energy range, the depth dose curves for the lower halogen-containing PRESAGE formulations are in better agreement with water than the original PRESAGE formulation. Conclusions: Based

  14. Development of an operational multicomponent personnel neutron dosimeter/spectrometer DOSPEC

    SciTech Connect

    Griffith, R.V.; McMahon, T.A.

    1983-10-26

    A multicomponent dosimeter has been developed that uses an albedo detector to provide the measurement of low energy neutrons and as a screening element. It also contains track detector components, CR-39 and polycarbonate, which are only processed if the TLD indicates there has been an exposure to neutrons. Since the three components have significantly different energy responses, the dosimeter can act as a crude spectrometer. This report describes the dosimeter and briefly summarizes its use experience. 10 refs., 2 figs., 2 tabs.

  15. Safety Is No Accident.

    ERIC Educational Resources Information Center

    Christiansen, Monty L.

    1985-01-01

    Liability suits involving accidents in park and recreation areas are expensive and intangible costs are incalculable. Risk management practices related to park planning, personnel, and administrative practices are discussed. (MT)

  16. Accident resistant transport container

    DOEpatents

    Andersen, John A.; Cole, James K.

    1980-01-01

    The invention relates to a container for the safe air transport of plutonium having several intermediate wood layers and a load spreader intermediate an inner container and an outer shell for mitigation of shock during a hypothetical accident.

  17. Accident resistant transport container

    DOEpatents

    Anderson, J.A.; Cole, K.K.

    The invention relates to a container for the safe air transport of plutonium having several intermediate wood layers and a load spreader intermediate an inner container and an outer shell for mitigation of shock during a hypothetical accident.

  18. Performance evaluation of diagnostic radiology dosimeters in clinical and calibration x-ray beams.

    PubMed

    Hourdakis, Costantine John; Boziari, Argyro; Manetou, Aggeliki

    2010-05-01

    Diagnostic radiology dosimeters should comply with International Electrotechnical Commission (IEC) 61674 standard in order to perform measurements with sufficient accuracy and reliability. The calibration of a dosimeter is performed under, and pertains to, reference conditions. However, in most cases, dosimeters are used for clinical measurements under non-reference conditions. The performance, in terms of accuracy of dose measurements, of six commercial diagnostic radiology dosimeters was tested at reference calibration and at clinical non-reference conditions. The results showed that all dosimeters being tested exhibited limits of variation within the +/-5% IEC limits. Depending on the detector's physical and operational properties, the dosimeters' energy dependence of response values varied from -4.7% to +4.2%. To address this variation of response, calibration at three radiation qualities (RQR 3, RQR 5, and RQR 9), at least, is recommended. Different irradiation conditions such as air kerma rate, x-ray tube design, x-ray system, and dosimeter operational modes affect the dosimeters' response by less than 3%. A dosimeter that complies with IEC standards and operates according to its specifications could be used at typical clinical irradiation conditions taking into account only corrections for the energy dependence of response. In this case, the error in dose accuracy is expected to be less than 3%. PMID:20386200

  19. FATAL ACCIDENT REPORTING SYSTEM (FARS)

    EPA Science Inventory

    The Fatal Accident Reporting System (FARS) database consist of three relational tables, containing data on automobile accidents on public U.S. roads that resulted in the death of one or more people within 30 days of the accident. Truck and trailer accidents are also included.

  20. Chemical dosimetry system for criticality accidents.

    PubMed

    Miljanić, Saveta; Ilijas, Boris

    2004-01-01

    Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values. PMID:15353694

  1. Accident management information needs

    SciTech Connect

    Hanson, D.J.; Ward, L.W.; Nelson, W.R.; Meyer, O.R. )

    1990-04-01

    In support of the US Nuclear Regulatory Commission (NRC) Accident Management Research Program, a methodology has been developed for identifying the plant information needs necessary for personnel involved in the management of an accident to diagnose that an accident is in progress, select and implement strategies to prevent or mitigate the accident, and monitor the effectiveness of these strategies. This report describes the methodology and presents an application of this methodology to a Pressurized Water Reactor (PWR) with a large dry containment. A risk-important severe accident sequence for a PWR is used to examine the capability of the existing measurements to supply the necessary information. The method includes an assessment of the effects of the sequence on the measurement availability including the effects of environmental conditions. The information needs and capabilities identified using this approach are also intended to form the basis for more comprehensive information needs assessment performed during the analyses and development of specific strategies for use in accident management prevention and mitigation. 3 refs., 16 figs., 7 tabs.

  2. Intercomparison of Reanalyses Dynamic Variables in the Stratosphere: Results from the SPARC-Reanalysis Intercomparison Project

    NASA Astrophysics Data System (ADS)

    Fujiwara, M.; Long, C. S.; Zhang, L.

    2014-12-01

    The Stratospheric-Tropospheric Processes and their Role in Climate (SPARC)-Reanalysis Intercomparison Project (S-RIP) is in the process of generating a multi-chapter report describing the thermal, dynamic, and chemical characteristics of the recent and past reanalyses. This presentation will focus on the basic characteristics of the thermal and dynamic variables (temperatures, heights, winds). In order to not favor any one particular reanalysis, an ensemble mean of the four most recent reanalyses [CFSR, MERRA, ERA-Interim, and the JRA55] has been created. Differences from this ensemble mean indicate how these four reanalyses and previous reanalyses differ in their long term climatology and time evolution of their dynamic variables at both poles and in the tropics. Differences from the ensemble mean indicate issues with how the analysis systems managed data poor time periods, consequences of bias correction, the transition from the SSU to AMSU observing systems, and differences in the annual amplitudes. The RMS of their differences over time indicates that there is an increase in their agreement from 1979 to present with greater agreement occurring in the AMSU time period.

  3. Water equivalence of NIPAM based polymer gel dosimeters with enhanced sensitivity for x-ray CT

    NASA Astrophysics Data System (ADS)

    Gorjiara, Tina; Hill, Robin; Bosi, Stephen; Kuncic, Zdenka; Baldock, Clive

    2013-10-01

    Two new formulations of N-isopropylacrylamide (NIPAM) based three dimensional (3D) gel dosimeters have recently been developed with improved sensitivity to x-ray CT readout, one without any co-solvent and the other one with isopropanol co-solvent. The water equivalence of the NIPAM gel dosimeters was investigated using different methods to calculate their radiological properties including: density, electron density, number of electrons per grams, effective atomic number, photon interaction probabilities, mass attenuation and energy absorption coefficients, electron collisional, radiative and total mass stopping powers and electron mass scattering power. Monte Carlo modelling was also used to compare the dose response of these gel dosimeters with water for kilovoltage and megavoltage x-ray beams and for megavoltage electron beams. We found that the density and electron density of the co-solvent free gel dosimeter are more water equivalent with less than a 2.6% difference compared to a 5.7% difference for the isopropanol gel dosimeter. Both the co-solvent free and isopropanol solvent gel dosimeters have lower effective atomic numbers than water, differing by 2.2% and 6.5%, respectively. As a result, their photoelectric absorption interaction probabilities are up to 6% and 19% different from water, respectively. Compton scattering and pair production interaction probabilities of NIPAM gel with isopropanol differ by up to 10% from water while for the co-solvent free gel, the differences are 3%. Mass attenuation and energy absorption coefficients of the co-solvent free gel dosimeter and the isopropanol gel dosimeter are up to 7% and 19% lower than water, respectively. Collisional and total mass stopping powers of both gel dosimeters differ by less than 2% from those of water. The dose response of the co-solvent free gel dosimeter is water equivalent (with <1% discrepancy) for dosimetry of x-rays with energies <100 keV while the discrepancy increases (up to 5%) for the

  4. [Psychogenesis of accidents].

    PubMed

    Giannattasio, E; Nencini, R; Nicolosi, N

    1988-01-01

    After having carried out a historical review of industrial psychology with specific attention to the evolution of the concept of causality in accidents, the Authors formulate their work hypothesis from that research which take into highest consideration the executives' attitudes in the genesis of the accidents. As dogmatism appears to be one of the most negative of executives' attitudes, the Authors administered Rockeach's Scale to 130 intermediate executives from 6 industries in Latium and observed the frequency index for accidents and the morbidity index (absenteeism) of the 2149 workhand. The Authors assumed that to high degree of dogmatism on the executives' side should correspond o a higher level of accidents and absenteeism among the staff. The data processing revealed that, due to the type of machinery employed, three of the industries examined should be considered as High Risk Industrie (HRI), while the remaining three could be considered as Low Risk Industries (LRI): in fact, due to the different working conditions, a significant lower number of accidents occurred in last the three. A statistically significant correlation between the executives' dogmatism and the number of accidents among their workhand in the HRI has been noticed, while this has not been observed in the LRI. This confirms, as had already been pointed out by Gemelli in 1944, that some "objective conditions" are requested so that the accident may actually take place. On the other hand the morbidity index has not shown any difference related to the different kind of industries (HRI, LRI): in both cases statistically significant correlations were obtained between the executives' dogmatism and the staff's absenteeism. absenteeism.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3154344

  5. Development of a scintillating optical fiber dosimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Moutinho, L. M.; Castro, I. F.; Peralta, L.; Abreu, M. C.; Veloso, J. F. C. A.

    2014-01-01

    A radiation dosimeter for low dose rates based on a scintillating optical fiber coupled to a high gain photon-counting silicon photomultiplier (SiPM) for light readout was developed. The dosimeter satisfies most of the requirements for in-vivo, low dose-rate and real-time dosimetry. The device uses a small scintillator, is flexible and reasonably water-equivalent for photon energies above 100 keV [1,2]. Promising results were obtained when operating the device in current mode, detecting radiation from an X-ray tube in the 15-40 kV range and for anode currents as low as a few μA. As single-photon detectors, the major drawback of SiPMs is their high dark count rate (noise), which is a problem for low dose rate measurements in single photon counting mode. This drawback can be reduced by cooling the SiPMs or by using a much more efficient proposed solution in which two SiPMs operate in coincidence mode reading out the same optical fiber, thus allowing the rejection of false events triggered by dark noise. We have implemented a simple low-cost system, with dedicated front-end electronics operating in pulse mode for coincidence detection. Performance studies of the dosimeter operating in current mode, as a function of the X-ray tube current and voltage, show good sensitivity even for low radiation dose. When operating in pulse mode under low activity gamma irradiation, the coincidence system was able to reduce the dark noise to a residual value.

  6. Electromagnetic field exposure dosimeter. Final report, September 1992-May 1993

    SciTech Connect

    Feaga, A.C.; Hilliard, M.P.; Link, R.

    1994-07-28

    The growing concern about adverse health effects caused by electromagnetic radiation prompted the ideas for this dosimeter. Data have been presented that link prolonged exposure to electromagnetic radiation from power lines to leukemia and some types of cancer. At present, though, there is a lack of recording instrumentation to measure the prolonged exposure of an individual; thus, it is not possible to correlate properly the amount of exposure or dose to health effects. With the recent advances in small, low-power devices, a small measuring device can be developed. Once this is built, a large data base can be obtained to help correlate electromagnetic field exposure to health conditions. The objective of this project is to develop an instrument which can measure electromagnetic fields over a prolonged period of time. The instrument would be small, say about the size of a radio Walkman, and would be worn throughout the day while taking data, as the individual goes about normal activities. A PC would be used to retrieve the data from the instrument at the end of the day. The dosimeter comprises a triaxial ferrite-loaded coil sensor, a set of amplifiers and filters, analog-to-digital converters, a microcontroller, and random access data memory. The signals from the sensor are filtered into three frequency ranges: one to measure 60-Hz exposure and two harmonics, another to measure high-energy pulsed energy, and a third frequency range to record the activity level of the individual. The signals from the filters are digitized and read into a microcontroller. The microcontroller performs a few calculations and controls the flow of the data to either random access memory or to a computer. A computer is used to retrieve the data from the dosimeter, and can store and display the measured data.

  7. An RF dosimeter for independent SAR measurement in MRI scanners

    PubMed Central

    Qian, Di; El-Sharkawy, AbdEl-Monem M.; Bottomley, Paul A.; Edelstein, William A.

    2013-01-01

    Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B1) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average

  8. Radiochromic leuko dye real time dosimeter, one way optical waveguide

    SciTech Connect

    Kronenberg, S.; McLaughlin, W.L.; Siebentritt, C.R.

    1984-12-18

    A radiochromic leuko dye dosimeter includes a plastic tube containing a solution of a radiochromic dye which is sensitive to ionizing radiation, one end of the tube being closed by a reflective surface, the opposite end of the tube being closed by a transparent plug to form a one-way optical waveguide. Light enters the tube through the transparent end thereof and is reflected back and exits through the transparent end. The intensity of the exiting light is measured to determine radiation induced absorption of the leuko dye.

  9. Lower limits of detection for thermal luminescent dosimeters

    SciTech Connect

    Spacher, P.J. ); Mis, F.J.; Klueber, M.R. )

    1990-08-01

    This paper reports that Groups of Panasonic UD-802 thermoluminescent dosimeters (TLDs) were irradiated to successively increasing doses of Cesium-137 gamma radiation (0.662 MeV gamma rays) and then processed using a Panasonic UD-710 automatic TLD reader. The results were subjected to statistical tests to determine the critical level, the level of detection, and the less-than level. The critical level is equivalent to 1.7 mrad, the lower limit of detection is equivalent to 5 mrad and the less-than level has a high range value of 7.5 mrad.

  10. An RF dosimeter for independent SAR measurement in MRI scanners

    SciTech Connect

    Qian, Di; Bottomley, Paul A.; El-Sharkawy, AbdEl-Monem M.; Edelstein, William A.

    2013-12-15

    Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on

  11. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    SciTech Connect

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, E.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements of the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.

  12. The April 1994 and October 1994 radon intercomparisons at EML

    SciTech Connect

    Fisenne, I.M.; George, A.C.; Perry, P.M.; Keller, H.W.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities and foreign institutions participated in these exercises. The majority of the participant`s results were within {+-}10% of the EML value at radon concentrations of 570 and 945 Bq m{sup {minus}3}.

  13. Results of the EURADOS extremity dosemeter intercomparison 2009.

    PubMed

    Stadtmann, H; Grimbergen, T W M; Figel, M; Romero, A M; McWhan, A F

    2011-03-01

    This paper presents the results of an intercomparison for extremity dosemeters organised by the European radiation dosimetry group in 2009. In total, 59 systems were tested during this exercise including ring, stall and wrist dosemeters. A total of 1652 dosemeters were irradiated in the selected fields of photons and beta radiation qualities on appropriate phantoms (ISO finger and pillar phantom) in the dose quantity H(p)(0.07). All irradiations were carried out in selected accredited reference dosemetry laboratories (Seibersdorf Laboratories, Austria and IRSN, France). The results show that, especially at low-energy beta radiations ((85)Kr) and for beta irradiations with large angles of incidence (60°), many tested systems show pronounced under responses. On the other hand, for photon irradiations down to energies of 16 keV most systems showed good results. A participants meeting was held at IM2010 with discussion on both general aspects of this intercomparison and specific problems. PMID:21196458

  14. The application of Sunna dosimeter film for process control at industrial gamma- and electron beam irradiation facilities

    NASA Astrophysics Data System (ADS)

    Kovács, A.; Baranyai, M.; Fuochi, P. G.; Lavalle, M.; Corda, U.; Miller, S.; Murphy, M.; O'Doherty, J.

    2004-09-01

    The Sunna dosimeter was introduced for dose determination in the dose range of 50-300 kGy by measuring optically stimulated luminescence. The usefulness of the dosimeter film has already been shown in food irradiation for routine process control. The aim of the present study was to check the performance of the Sunna dosimeter film for process control in radiation sterilization under industrial processing conditions, i.e. at high activity gamma irradiators and at high energy electron beam facilities. To ensure similar irradiation conditions during calibration and routine irradiation "in-plant calibration" was performed by irradiating the Sunna dosimeters together with ethanol-monochlorobenzene transfer standard and alanine reference standard dosimeters. The Sunna dosimeters were then irradiated together with the routine dosimeter of the actual plant during regular production runs and the absorbed doses measured by the different dosimeters agreed within ±2%(1 σ).

  15. The WMO Field Intercomparison of Rain Intensity Gauges

    NASA Astrophysics Data System (ADS)

    Lanza, Luca G.; Vuerich, E.

    2009-12-01

    The first Field Intercomparison of Rainfall Intensity (RI) gauges was organised by WMO (the World Meteorological Organisation) from October 2007 to April 2009 in Vigna di Valle, Rome (Italy). The campaign is held at the Centre of Meteorological Experimentations (ReSMA) of the Italian Meteorological Service. A group of 30 previously selected rain gauges based on different measuring principles are involved in the Intercomparison. Installation of the instruments in the field was preceded by the laboratory calibration of all submitted catching-type rain gauges at the University of Genoa. Additional meteorological sensors (ancillary information) and the observations and measurements performed by the Global Climate Observing System/Global Atmosphere Watch (GCOS/GAW) meteorological station of Vigna di Valle were analyzed as metadata. All catching-type gauges were tested after installation using a portable calibration device specifically developed at the University of Genoa, simulating an ordinary calibration inspection in the field. This paper is dedicated to the summary of preliminary results of the Intercomparison measurements. It offers a view on the main achievements expected from the Intercomparison in evaluating the performance of the instruments in field conditions. Comparison of several rain gauges demonstrated the possibility to evaluate the performance of RI gauges at one-minute resolution in time, as recommended by the WMO Commission for Instruments and Methods of Observations (WMO-CIMO). Results indicate that synchronised tipping-bucket rain gauges (TBR), using internal correction algorithms, and weighing gauges (WG) with improved dynamic stability and short step response are the most accurate gauges for one-minute RI measurements, since providing the lowest measurement uncertainty with respect to the assumed working reference.

  16. Intercomparison of TCCON and MUSICA Water Vapour Products

    NASA Astrophysics Data System (ADS)

    Weaver, D.; Strong, K.; Deutscher, N. M.; Schneider, M.; Blumenstock, T.; Robinson, J.; Notholt, J.; Sherlock, V.; Griffith, D. W. T.; Barthlott, S.; García, O. E.; Smale, D.; Palm, M.; Jones, N. B.; Hase, F.; Kivi, R.; Ramos, Y. G.; Yoshimura, K.; Sepúlveda, E.; Gómez-Peláez, Á. J.; Gisi, M.; Kohlhepp, R.; Warneke, T.; Dohe, S.; Wiegele, A.; Christner, E.; Lejeune, B.; Demoulin, P.

    2014-12-01

    We present an intercomparison between the water vapour products from the Total Carbon Column Observing Network (TCCON) and the MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water (MUSICA), two datasets from ground-based Fourier Transform InfraRed (FTIR) spectrometers with good global representation. Where possible, comparisons to radiosondes are also included. The near-infrared TCCON measurements are optimized to provide precise monitoring of greenhouse gases for carbon cycle studies; however, TCCON's retrievals also produce water vapour products. The mid-infrared MUSICA products result from retrievals optimized to give precise and accurate information about H2O, HDO, and δD. The MUSICA water vapour products have been validated by extensive intercomparisons with H2O and δD in-situ measurements made from ground, radiosonde, and aircraft (Schneider et al. 2012, 2014), as well as by intercomparisons with satellite-based H2O and δD remote sensing measurements (Wiegele et al., 2014). This dataset provides a valuable reference point for other measurements of water vapour. This study is motivated by the limited intercomparisons performed for TCCON water vapour products and limited characterisation of their uncertainties. We compare MUSICA and TCCON products to assess the potential for TCCON measurements to contribute to studies of the water cycle, water vapour's role in climate and use as a tracer for atmospheric dynamics, and to evaluate the performance of climate models. The TCCON and MUSICA products result from measurements taken using the same FTIR instruments, enabling a comparison with constant instrumentation. The retrieval techniques differ, however, in their method and a priori information. We assess the impact of these differences and characterize the comparability of the TCCON and MUSICA datasets.

  17. An Intercomparison of Airborne VOC and PAN Measurements

    NASA Astrophysics Data System (ADS)

    Hansel, A.; Wisthaler, A.; Flocke, F.; Weinheimer, A.; Fall, R.; Goldan, P.; Hübler, G.; Fehsenfeld, F. C.

    2002-12-01

    As part of the Texas Air Quality Study (TexAQS 2000) an informal airborne intercomparison has been conducted to evaluate the state-of-the-art of fast-response, in-situ methods for analyzing Volatile Organic Compounds (VOCs) and peroxyacetyl nitrate (PAN). Instrumentation included a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS), the Tropospheric Airborne Chromatograph for Oxy-hydrocarbons and Hydrocarbons (TACOH) and a gas chromatograph for PAN detection using electron capture (GC/ECD). The measurements were made in the Greater Houston area and East Texas in August/September 2000 during 13 flights with the NSF/NCAR ELECTRA aircraft. The intercomparison was conducted mainly in the boundary layer but included some encounters with air masses from the free troposphere. Final results from the intercomparison show that measurements of acetaldehyde, isoprene, the sum\\textsuperscript{*} of acetone and propanal, the sum\\textsuperscript{*} methyl vinyl ketone and methacrolein (\\textsuperscript{*} PTR-MS does not distinguish between isobaric species) and toluene agree very well. Poor agreement was achieved in the case of methanol and the underlying sensitivity problem in the PTR-MS or TACOH system is under investigation. The results of the PAN intercomparison indicate that the PTR-MS technique suffered from an interference most likely associated with the presence of peracetic acid in photochemically aged air. If this interfering signal was traced by periodically inserting a selective PAN scrubber (thermal decomposition) into the sample air stream and subtracted from the original signal, the corrected PTR-MS PAN data are in very good agreement with the GC/ECD results.

  18. Bootstrap-based intercomparison of regional flood estimation procedures

    SciTech Connect

    Ouarda, T.B.M.J.; Ashkar, F.

    1995-12-31

    The present paper describes a methodology, based on the regional bootstrap procedure, for the intercomparison of some of the most frequently used regional flood frequency estimation models. The results of the application of this methodology, with Canadian flood data, for comparing the different regional estimation models are also presented. A regional model C{sub ij} = [DRH]{sub i} x [MER]{sub j} (i=1,...,L ; j=1,...,M) is obtained by combining a methodology for the delineation of homogeneous regions [DRH]{sub i} and a regional estimation method [MER]{sub j}. These regional models are compared with respect to their ability to provide reliable estimates of certain flood quantiles (floods with return periods of 10 and 100 years). Two types of bootstrapping have been applied within the framework of this project: the classical scalar bootstrap used in at-site estimation, and the vector (or regional) bootstrap procedure applied in the intercomparison between the different regional models. This last technique is illustrated with an example, and all the details of the procedure are presented. The performance indices that were employed for the purpose of the intercomparison are also detailed. One important feature of regional bootstrapping is that it preserves the regional dependence structure between annual flood values at the different sites of an {open_quote}homogeneous{close_quote} region. Three versions of the regional bootstrap algorithm are presented and applied to the three cases of estimation-regional estimation for ungauged sites, regional estimation for gauged sites with a short record, and at-site estimation. It will be shown how at-site estimates can be used as basis for the intercomparison between the regional models. Results of the application of the bootstrap procedure, with flood data from the Provinces of Quebec and Ontario, are presented in the final section of the paper.

  19. Adaptation of a Pocket PC for Use as a Wearable Voice Dosimeter

    ERIC Educational Resources Information Center

    Popolo, Peter S.; Svec, Jan G.; Titze, Ingo R.

    2005-01-01

    This article deals with the adaptation of a commercially available Pocket PC for use as a voice dosimeter, a wearable device that measures the vocal dose of teachers or other individuals on the job, at home, and elsewhere during the course of an entire day. An engineering approach for designing a voice dosimeter is described, and design data are…

  20. Ceric and ferrous dosimeters show precision for 50-5000 rad range

    NASA Technical Reports Server (NTRS)

    Frigerio, N. A.; Henry, V. D.

    1968-01-01

    Ammonium thiocyanate, added to the usual ferrous sulfate dosimeter solution, yielded a very stable, precise and temperature-independent system eight times as sensitive as the classical Fricke system in the 50 to 5000 rad range. The ceric dosimeters, promising for use in mixed radiation fields, respond nearly independently of LET.

  1. PRESAGETM - Development and optimization studies of a 3D radiochromic plastic dosimeter - Part 1

    NASA Astrophysics Data System (ADS)

    Adamovics, J.; Jordan, K.; Dietrich, J.

    2006-12-01

    This paper studies the polymerization of six different transparent plastics as potential 3D dosimeter matrices. In addition, six different leuco dyes and sixteen different free radical initiators were evaluated. Finally, the photoreactivity of the dosimeter was studied so that the effect of exposure to UV could be minimized.

  2. Longevity Tests of High-Sensitivity BD-PND Bubble Dosimeters

    SciTech Connect

    Radev, R; Carlberg, E

    2002-07-09

    Medium- and very-high-sensitivity neutron bubble dosimeters (BD-PNDs) made by Bubble Technology Industries (BTI) were used to study the life span of such dosimeters in a standard setup with a {sup 252}Cf source. Although data on the longevity of bubble dosimeters with low and medium sensitivity exist, such data for dosimeters with high and very high sensitivity are not readily available. The manufacturer guarantees optimum dosimeter performance for 3 months after receipt. However, it is important to know the change in the dosimeters' characteristics with time, especially after the first 3 months. The long-term performance of four sets of very high sensitivity and one set of medium-sensitivity bubble dosimeters was examined for periods of up to 13 months. During that time, the detectors were exposed and reset more than 20 times. Although departures from initial detection sensitivity were observed in several cases, the detectors indicated a significantly longer life span than stated in the manufacturer's warranty. In addition, the change in the number of bubbles and in evaluated neutron dose as a function of the time from the end of exposure until the dosimeters were read was investigated.

  3. EARLINET instrument intercomparison campaigns: overview on strategy and results

    NASA Astrophysics Data System (ADS)

    Wandinger, Ulla; Freudenthaler, Volker; Baars, Holger; Amodeo, Aldo; Engelmann, Ronny; Mattis, Ina; Groß, Silke; Pappalardo, Gelsomina; Giunta, Aldo; D'Amico, Giuseppe; Chaikovsky, Anatoli; Osipenko, Fiodor; Slesar, Alexander; Nicolae, Doina; Belegante, Livio; Talianu, Camelia; Serikov, Ilya; Linné, Holger; Jansen, Friedhelm; Apituley, Arnoud; Wilson, Keith M.; de Graaf, Martin; Trickl, Thomas; Giehl, Helmut; Adam, Mariana; Comerón, Adolfo; Muñoz-Porcar, Constantino; Rocadenbosch, Francesc; Sicard, Michaël; Tomás, Sergio; Lange, Diego; Kumar, Dhiraj; Pujadas, Manuel; Molero, Francisco; Fernández, Alfonso J.; Alados-Arboledas, Lucas; Bravo-Aranda, Juan Antonio; Navas-Guzmán, Francisco; Guerrero-Rascado, Juan Luis; José Granados-Muñoz, María; Preißler, Jana; Wagner, Frank; Gausa, Michael; Grigorov, Ivan; Stoyanov, Dimitar; Iarlori, Marco; Rizi, Vincenco; Spinelli, Nicola; Boselli, Antonella; Wang, Xuan; Lo Feudo, Teresa; Perrone, Maria Rita; De Tomasi, Ferdinando; Burlizzi, Pasquale

    2016-03-01

    This paper introduces the recent European Aerosol Research Lidar Network (EARLINET) quality-assurance efforts at instrument level. Within two dedicated campaigns and five single-site intercomparison activities, 21 EARLINET systems from 18 EARLINET stations were intercompared between 2009 and 2013. A comprehensive strategy for campaign setup and data evaluation has been established. Eleven systems from nine EARLINET stations participated in the EARLINET Lidar Intercomparison 2009 (EARLI09). In this campaign, three reference systems were qualified which served as traveling standards thereafter. EARLINET systems from nine other stations have been compared against these reference systems since 2009. We present and discuss comparisons at signal and at product level from all campaigns for more than 100 individual measurement channels at the wavelengths of 355, 387, 532, and 607 nm. It is shown that in most cases, a very good agreement of the compared systems with the respective reference is obtained. Mean signal deviations in predefined height ranges are typically below ±2 %. Particle backscatter and extinction coefficients agree within ±2 × 10-4 km-1 sr-1 and ± 0.01 km-1, respectively, in most cases. For systems or channels that showed larger discrepancies, an in-depth analysis of deficiencies was performed and technical solutions and upgrades were proposed and realized. The intercomparisons have reinforced confidence in the EARLINET data quality and allowed us to draw conclusions on necessary system improvements for some instruments and to identify major challenges that need to be tackled in the future.

  4. EARLINET instrument intercomparison campaigns: overview on strategy and results

    NASA Astrophysics Data System (ADS)

    Wandinger, U.; Freudenthaler, V.; Baars, H.; Amodeo, A.; Engelmann, R.; Mattis, I.; Groß, S.; Pappalardo, G.; Giunta, A.; D'Amico, G.; Chaikovsky, A.; Osipenko, F.; Slesar, A.; Nicolae, D.; Belegante, L.; Talianu, C.; Serikov, I.; Linné, H.; Jansen, F.; Apituley, A.; Wilson, K. M.; de Graaf, M.; Trickl, T.; Giehl, H.; Adam, M.; Comerón, A.; Muñoz, C.; Rocadenbosch, F.; Sicard, M.; Tomás, S.; Lange, D.; Kumar, D.; Pujadas, M.; Molero, F.; Fernández, A. J.; Alados-Arboledas, L.; Bravo-Aranda, J. A.; Navas-Guzmán, F.; Guerrero-Rascado, J. L.; Granados-Muñoz, M. J.; Preißler, J.; Wagner, F.; Gausa, M.; Grigorov, I.; Stoyanov, D.; Iarlori, M.; Rizi, V.; Spinelli, N.; Boselli, A.; Wang, X.; Lo Feudo, T.; Perrone, M. R.; De Tomasi, F.; Burlizzi, P.

    2015-10-01

    This paper introduces the recent EARLINET quality-assurance efforts at instrument level. Within two dedicated campaigns and five single-site intercomparison activities 21 EARLINET systems from 18 EARLINET stations were intercompared between 2009 and 2013. A comprehensive strategy for campaign setup and data evaluation has been established. Eleven systems from nine EARLINET stations participated in the EARLINET Lidar Intercomparison 2009 (EARLI09). In this campaign, three reference systems were qualified which served as traveling standards thereafter. EARLINET systems from nine other stations have been compared against these reference systems since 2009. We present and discuss comparisons at signal and at product level from all campaigns for more than 100 individual measurement channels at the wavelengths of 355, 387, 532 and 607 nm. It is shown that in most cases a very good agreement of the compared systems with the respective reference is obtained. Mean signal deviations in pre-defined height ranges are typically below ±2 %. Particle backscatter and extinction coefficients agree within ±2 × 10-4 km-1 sr-1 and ± 0.01 km-1, respectively, in most cases. For systems or channels that showed larger discrepancies, an in-depth analysis of deficiences was performed and technical solutions and upgrades were proposed and realized. The intercomparisons have reinforced the confidence in the EARLINET data quality and allowed us to draw conclusions on necessary system improvements for some instruments and to identify major challenges that need to be tackled in the future.

  5. Inter-comparison between AIRS and IASI through Retrieved Parameters

    NASA Technical Reports Server (NTRS)

    Zhou, Daniel K.; Larar, Allen M.; Smith, William L.; Taylor, Jonathan P.; Schluessel, Peter; Strow, L. Larrabee; Mango, Steve

    2008-01-01

    A State-of-the-art retrieval algorithm dealing with all-weather conditions has been applied to satellite/aircraft instruments retrieving cloud/surface and atmospheric conditions. High quality retrievals have been achieved from IASI data. Surface, cloud, and atmospheric structure and variation are well captured by IASI measurements and/or retrievals. The same retrieval algorithm is also applied to AIRS for retrieval inter-comparison. Both AIRS and IASI have a similar FOV size but AIRS has a higher horizontal resolution. AIRS data can be interpolated to IASI horizontal resolution for inter-comparison at the same geophysical locations, however a temporal variation between AIRS and IASI observations need to be considered. JAIVEx has employed aircraft to obtain the atmospheric variation filling the temporal gap between two satellites. First results show that both AIRS and IASI have a very similar vertical resolving power, atmospheric conditions are well captured by both instruments, and radiances are well calibrated. AIRS data shown in retrievals (e.g., surface emissivity and moisture) have a relatively higher noise level. Since the this type of retrieval is very sensitive to its radiance quality, retrieval products inter-comparison is an effective way to identify/compare their radiance quality, in terms of a combination of spectral resolution and noise level, and to assess instrument performance. Additional validation analyses are needed to provide more-definitive conclusions.

  6. GABLS4: a model intercomparison study in extremely stable conditions

    NASA Astrophysics Data System (ADS)

    Bazile, Eric; Le Moigne, Patrick; Couvreux, Fleur

    2016-04-01

    In polar regions and under stable stratifications, models presents large biases that are dependent upon the parametrizations used for the surface and boundary layers (Holtslag et al., 2013). The GABLS4 inter-comparison, launched in summer 2014, aims to study the diurnal cycles over the Antarctic Plateau, focussing on the boundary layer characteristics and the coupling with the surface in strong stability. For this, the observation site of Dome C on the Antarctic Plateau was chosen mainly for two reasons: the availability of the on-site measurements from a 45-m tower and a homogeneous surface with a low conductivity such as snow on a flat topography. The inter-comparison will consist of 3 inter-comparisons : Single Column Model (SCM), Large Eddy Simulation (LES) and land-snow model (LSM). It is organized in two steps. The first one is dedicated to the LSM and the SCM with an interactive surface (snow) scheme. Then, in the second one, the observed surface temperature will be prescribed in the SCM and in the LES models. A large variability in surface fluxes was highlighted in all types of simulations with variations about 30W/m2 during daytime and night-time which is about 100% of the ensemble mean value. After a rapid overview of the setup, we will focus on the SCM results and how the results are sensitive to the surface characteristics and the vertical resolution.

  7. SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENT.

    PubMed

    Rojo, A; Puerta, N; Gossio, S; Gómez Parada, I; Cruz Suarez, R; López, E; Medina, C; Lastra Boylan, J; Pinheiro Ramos, M; Mora Ramírez, E; Alves Dos Reis, A; Yánez, H; Rubio, J; Vironneau Janicek, L; Somarriba Vanegas, F; Puerta Ortiz, J; Salas Ramírez, M; López Bejerano, G; da Silva, T; Miri Oliveira, C; Terán, M; Alfaro, M; García, T; Angeles, A; Duré Romero, E; Farias de Lima, F

    2016-09-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers. PMID:26503854

  8. Injuries are not accidents

    PubMed Central

    Gutiérrez, María Isabel

    2014-01-01

    Injuries are the result of an acute exposure to exhort of energy or a consequence of a deficiency in a vital element that exceeds physiological thresholds resulting threatens life. They are classified as intentional or unintentional. Injuries are considered a global health issue because they cause more than 5 million deaths per year worldwide and they are an important contributor to the burden of disease, especially affecting people of low socioeconomic status in low- and middle-income countries. A common misconception exists where injuries are thought to be the same as accidents; however, accidents are largely used as chance events, without taken in consideration that all these are preventable. This review discusses injuries and accidents in the context of road traffic and emphasizes injuries as preventable events. An understanding of the essence of injuries enables the standardization of terminology in public use and facilitates the development of a culture of prevention among all of us. PMID:25386040

  9. Accidents in Childhood

    PubMed Central

    Keddy, J. Arthur

    1964-01-01

    The causes of injury to 17,141 children brought to the emergency department of a large pediatric hospital in one year were studied. The leading causes of injury were: falls, 5682; cuts or piercings, 1902; poisonings, 1597; and transportation accidents, 1368. Included in these are 587 falls on or down stairs, 401 cuts due to glass, 630 poisonings from household or workshop substances, 510 poisonings from salicylate tablets, and 449 accidents involving bicycles or tricycles. Other findings included 333 injuries to fingers or hands in doors, usually car doors; 122 instances of pulled arms; 384 ingestions and 53 inhalations of foreign bodies; 60 alleged sexual assaults, 58 chemical burns, 127 wringer injuries, and four attempted suicides. A rewarding opportunity in accident prevention exists for hospitals that undertake to compile and distribute pertinent source data. PMID:14201260

  10. Dosimeter for the measurement of UV exposures related to melanoma induction.

    PubMed

    Turnbull, David J; Parisi, Alfio V

    2010-07-01

    This paper reports on the development of a dosimeter for the measurement of biologically effective UV exposures related to melanoma induction. The melanoma (UVMel) dosimeter is based on the combination of polysulfone and nalidixic acid. This research found that the combination of these photosensitive chromophores reacts to UV wavelengths from 290 to 390 nm. It was found that a large change in optical absorbance occurred at 345 nm when the dosimeter was employed to quantify the solar UV waveband. Preliminary results indicate that this UVMel dosimeter can measure exposures of more than 189 kJ m(-2) of biologically effective weighted solar UV radiation with an inter-dosimeter variability of no more than +/-5%. PMID:20551501

  11. Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry

    PubMed Central

    Lee, Bongsoo; Kwon, Guwon; Shin, Sang Hun; Kim, Jaeseok; Yoo, Wook Jae; Ji, Young Hoon; Jang, Kyoung Won

    2015-01-01

    In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter. PMID:26593917

  12. The Fukushima radiation accident: consequences for radiation accident medical management.

    PubMed

    Meineke, Viktor; Dörr, Harald

    2012-08-01

    The March 2011 radiation accident in Fukushima, Japan, is a textbook example of a radiation accident of global significance. In view of the global dimensions of the accident, it is important to consider the lessons learned. In this context, emphasis must be placed on consequences for planning appropriate medical management for radiation accidents including, for example, estimates of necessary human and material resources. The specific characteristics of the radiation accident in Fukushima are thematically divided into five groups: the exceptional environmental influences on the Fukushima radiation accident, particular circumstances of the accident, differences in risk perception, changed psychosocial factors in the age of the Internet and globalization, and the ignorance of the effects of ionizing radiation both among the general public and health care professionals. Conclusions like the need for reviewing international communication, interfacing, and interface definitions will be drawn from the Fukushima radiation accident. PMID:22951483

  13. A modified Fricke gel dosimeter for fast electron blood dosimetry

    NASA Astrophysics Data System (ADS)

    Del Lama, L. S.; de Góes, E. G.; Sampaio, F. G. A.; Petchevist, P. C. D.; de Almeida, A.

    2014-12-01

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXGp) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXGp dosimeter were also able to provide isodose curves and field profiles for the irradiated samples.

  14. Development of a passive dosimeter for hydrogen fluoride monitoring

    SciTech Connect

    Young, M.S.; Monat, J.P.

    1983-02-01

    Hydrogen fluoride (HF), a toxic industrial chemical, is used in the manufacture of most fluorine products and in many other industrial processes. Major uses are in fluorocarbon manufacture, aluminum production, glass etching, steel pickling, uranium processing, and as a catalyst for petroleum refining. A reliable passive dosimeter has been developed for sampling of airborne hydrogen fluoride vapor. The device is small (7.7 cm x 5.4 cm x 1.9 cm) and can easily and conveniently be worn on one's lapel. It consists of polyethylene and polypropylene parts and an alkaline impregnated polypropylene collection element. It is completely self-contained requiring no pumps, impingers, or sampling tubes. Subsequent to sampling, the collection element is analyzed quickly and easily with a fluoride selective-ion electrode. Laboratory tests were conducted to determine precision, linearity, interference effects, influences of temperature and humidity, and collection element stability over time. Results of the tests indicate that the Gasbadge/sup TM/ HF dosimeter is an excellent passive HF monitor for work spaces, and that results obtained with it are accurate within +/- 17.4% in the action range and +/- 10.3% overall. These results have been corroborated in a field study. (JMT)

  15. Intercomparison measurements with energy deposition spectrometer Liulin and TEPC Hawk at HIMAC, and related calculations with PHITS

    NASA Astrophysics Data System (ADS)

    Ploc, Ondrej; Uchihori, Yukio; Kitamura, H.; Kodaira, S.; Dachev, Tsvetan; Spurny, Frantisek; Jadrnickova, Iva; Mrazova, Zlata; Kubancak, Jan

    Liulin type detectors are recently used in a wide range of cosmic radiation measurements, e.g. at alpine observatories, onboard aircrafts and spacecrafts. They provide energy deposition spectra up to 21 MeV, higher energy deposition events are stored in the last (overflow) channel. Their main advantages are portability (about the same size as a pack of cigarettes) and ability to record spectra as a function of time, so they can be used as personal dosimeters. Their well-known limitations are: (i) the fact that they are not tissue equivalent, (ii) they can be used as LET spectrometer only under specific conditions (e.g. broad parallel beam), and (iii) that the energy deposition event from particles of LETH20¿35 keV/µm is stored in the overflow bin only so the spectral information is missing. Tissue equivalent proportional counter (TEPC) Hawk has no of these limitations but on the other hand, it cannot be used as personal dosimeter because of its big size (cylinder of 16 cm diameter and 34 cm long). An important fraction of dose equivalent onboard spacecrafts is caused by heavy ions. This contribution presents results from intercomparison measurements with Liulin and Hawk at Heavy Ion Medical Accelerator in Chiba (HIMAC) and cyclotron beams, and related calculations with PHITS (Particle and Heavy-ion Transport code System). Following particles/ions and energies were used: protons 70 MeV, He 150 MeV, Ne 400 MeV, C 135 MeV, C 290 MeV, and Fe 500 MeV. Calculations of LET spectra by PHITS were performed for both, Liulin and Hawk. In case of Liulin, the dose equivalent was calculated using simulations in which several tissue equivalent materials were used as active volume instead of the silicon diode. Dose equivalents calculated in such way was compared with that measured with Hawk. LET spectra measured with Liulin and Hawk were compared for each ion at several points behind binary filters along the Brag curve. Good agreement was observed for some configurations; for

  16. Physics in Accident Investigations.

    ERIC Educational Resources Information Center

    Brake, Mary L.

    1981-01-01

    Describes physics formulas which can be used by law enforcement officials to determine the possible velocity of vehicles involved in traffic accidents. These include, among others, the slide to stop-level road, slide to stop-sloping roadway, and slide to stop-two different surfaces formulas. (JN)

  17. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

    SciTech Connect

    McCaw, Travis J. Micka, John A.; DeWerd, Larry A.

    2014-05-15

    Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the

  18. Characterization of the nanoDot OSLD dosimeter in CT

    PubMed Central

    Scarboro, Sarah B.; Cody, Dianna; Alvarez, Paola; Followill, David; Court, Laurence; Stingo, Francesco C.; Zhang, Di; Kry, Stephen F.

    2015-01-01

    Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due

  19. Characterization of the nanoDot OSLD dosimeter in CT

    SciTech Connect

    Scarboro, Sarah B.; Cody, Dianna; Followill, David; Court, Laurence; Stingo, Francesco C.; Kry, Stephen F.; Alvarez, Paola; Zhang, Di; McNitt-Gray, Michael

    2015-04-15

    Purpose: The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. Methods: A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80–140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. Results: Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. Conclusions: Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due

  20. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere

    NASA Astrophysics Data System (ADS)

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of 137Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  1. Evaluation of a high exposure solar UV dosimeter for underwater use.

    PubMed

    Schouten, Peter W; Parisi, Alfio V; Turnbull, David J

    2007-01-01

    Solar ultraviolet radiation (UV) is known to have a significant effect upon the marine ecosystem. This has been documented by many previous studies using a variety of measurement methods in aquatic environments such as oceans, streams and lakes. Evidence gathered from these investigations has shown that UVB radiation (280-320 nm) can negatively affect numerous aquatic life forms, while UVA radiation (320-400 nm) can both damage and possibly even repair certain types of underwater life. Chemical dosimeters such as polysulphone have been tested to record underwater UV exposures and in turn quantify the relationship between water column depth and dissolved organic carbon levels to the distribution of biologically damaging UV underwater. However, these studies have only been able to intercept UV exposures over relatively short time intervals. This paper reports on the evaluation of a high exposure UV dosimeter for underwater use. The UV dosimeter was fabricated from poly 2,6-dimethyl-1,4-phenylene oxide (PPO) film. This paper presents the dose response, cosine response, exposure additivity and watermarking effect relating to the PPO dosimeter as measured in a controlled underwater environment and will also detail the overnight dark reaction and UVA and visible radiation response of the PPO dosimeter, which can be used for error correction to improve the reliability of the UV data measured by the PPO dosimeters. These results show that this dosimeter has the potential for long-term underwater UV exposure measurements. PMID:17645666

  2. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere

    SciTech Connect

    Yang, Zhen; Chen, Bo Zhuo, Weihai; Fan, Dunhuang; Zhang, Yu; Zhao, Chao

    2015-12-15

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of {sup 137}Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account.

  3. The responses of three kinds of passive dosimeters to secondary cosmic rays in the lower atmosphere.

    PubMed

    Yang, Zhen; Chen, Bo; Zhuo, Weihai; Fan, Dunhuang; Zhao, Chao; Zhang, Yu

    2015-12-01

    For accurate measurements of the secondary cosmic rays by using passive dosimeters, the relative responses of the thermoluminescence dosimeter (TLD), optically stimulated luminescence (OSL) dosimeter, and radiophotoluminescent glass dosimeter (RPLGD) were studied. The cosmic-ray shower generator was used to simulate the secondary cosmic rays at the sea level. Monte Carlo simulations were performed to calculate the air kerma and absorbed doses in each kind of dosimeter. The results showed that compared with their responses to gamma rays of (137)Cs, the relative responses of the TLD, OSL, and RPLGD were 0.786, 0.707, and 0.735 to the hard component of cosmic rays, respectively, and the values were 0.904, 0.838, and 0.857 to the soft component of cosmic rays, respectively. To verify the simulations results, an in situ measurement with the three kinds of dosimeters was performed at the same place. The results indicated that the secondary cosmic rays monitored with the three kinds of dosimeters were well consistent with each other provided their relative responses were taken into account. PMID:26724019

  4. Monte Carlo simulation of single and two-dosimeter approaches in a steam generator channel head.

    PubMed

    Kim, C H; Reece, W D

    2002-08-01

    In a steam generator channel head, it was not unusual to see radiation workers wearing as many as twelve dosimeters over the surface of the body to avoid a possible underestimation of effective dose equivalent (H(E)) or effective dose (E). This study shows that only one or two dosimeters can be used to estimate H(E) and E without a significant underestimation. MCNP and a point-kernel approach were used to model various exposure situations in a steam generator channel head. The single-dosimeter approach (on the chest) was found to underestimate H(E) and E significantly for a few exposure situations, i.e., when the major portion of radiation source is located in the backside of a radiation worker. In this case, the photons from the source pass through the body and are attenuated before reaching the dosimeter on the chest. To assure that a single dosimeter provides a good estimate of worker dose, these few exposure situations cannot dominate a worker's exposure. On the other hand, the two-dosimeter approach (on the chest and back) predicts H(E) and E very well, hardly ever underestimating these quantities by more than 4% considering all worker positions and contamination situations in a steam generator channel head. This study shows that two dosimeters are adequate for an accurate estimation of H(E) and E in a steam generator channel head. PMID:12132712

  5. Postirradiation effects in alanine dosimeter probes of two different suppliers.

    PubMed

    Anton, Mathias

    2008-03-01

    The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, DW. The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for DW for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical applications, like, for example, intercomparison measurements using the ESR/alanine dosimetry system, the temporal evolution of the ESR signal of irradiated probes is an important issue. This postirradiation behaviour is investigated for alanine pellets of two different suppliers for different storage conditions. The influence of the storage conditions on the temporal evolution may be dependent on the type of probes used. The measurement and analysis method developed at the PTB is able to circumvent the apparent difficulties in the case of alanine/paraffin probes. Care has to be taken in case this method cannot be applied. PMID:18296760

  6. Dose evaluation in criticality accident conditions using transient critical facilities fueled with a fissile solution.

    PubMed

    Nakamura, T; Tonoike, K; Miyoshi, Y

    2004-01-01

    Neutron dose measurement and evaluation techniques in criticality accident conditions using a thermo luminescence dosemeter (TLD) was studied at the Transient Experiment Critical Facility (TRACY) of Japan Atomic Energy Research Institute (JAERI). In the present approach, the absorbed dose is derived from the ambient dose equivalent measured with a TLD, using the appropriate conversion factor given by computation. Using this technique, the neutron dose around the SILENE reactor of the Institute for Radioprotection and Nuclear Safety (IRSN) of France was measured in the Accident Dosimetry Intercomparison Exercise (June 10-21, 2002) organized by OECD/NEA and IRSN. In this exercise, the gamma dose was also measured with a TLD. In this report, measurements and evaluation results at TRACY and SILENE are presented. PMID:15353695

  7. Applying STAMP in Accident Analysis

    NASA Technical Reports Server (NTRS)

    Leveson, Nancy; Daouk, Mirna; Dulac, Nicolas; Marais, Karen

    2003-01-01

    Accident models play a critical role in accident investigation and analysis. Most traditional models are based on an underlying chain of events. These models, however, have serious limitations when used for complex, socio-technical systems. Previously, Leveson proposed a new accident model (STAMP) based on system theory. In STAMP, the basic concept is not an event but a constraint. This paper shows how STAMP can be applied to accident analysis using three different views or models of the accident process and proposes a notation for describing this process.

  8. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    SciTech Connect

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford`s mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  9. Response of TLD-albedo and nuclear track dosimeters exposed to plutonium sources

    SciTech Connect

    Brackenbush, L.W.; Baumgartner, W.V.; Fix, J.J.

    1991-12-01

    Neutron dosimetry has been extensively studied at Hanford since the mid-1940s. At the present time, Hanford contractors use thermoluminescent dosimeter (TLD)-albedo dosimeters to record the neutron dose equivalent received by workers. The energy dependence of the TLD-albedo dosimeter has been recognized and documented since introduced at Hanford in 1964 and numerous studies have helped assure the accuracy of dosimeters. With the recent change in Hanford's mission, there has been a significant decrease in the handling of plutonium tetrafluoride, and an increase in the handling of plutonium metal and plutonium oxide sources. This study was initiated to document the performance of the current Hanford TLD-albedo dosimeter under the low scatter conditions of the calibration laboratory and under the high scatter conditions in the work place under carefully controlled conditions at the Plutonium Finishing Plant (PFP). The neutron fields at the PFP facility were measured using a variety of instruments, including a multisphere spectrometer, tissue equivalent proportional counters, and specially calibrated rem meters. Various algorithms were used to evaluate the TLD-albedo dosimeters, and the results are given in this report. Using current algorithms, the dose equivalents evaluated for bare sources and sources with less than 2.5 cm (1 in.) of acrylic plastic shielding in high scatter conditions typical of glove box operations are reasonably accurate. Recently developed CR-39 track etch dosimeters (TEDs) were also exposed in the calibration laboratory and at the PFP. The results indicate that the TED dosimeters are quite accurate for both bare and moderated neutron sources. Until personnel dosimeter is available that incorporates a direct measure of the neutron dose to a person, technical uncertainties in the accuracy of the recorded data will continue.

  10. An NMR relaxometry and gravimetric study of gelatin-free aqueous polyacrylamide dosimeters

    NASA Astrophysics Data System (ADS)

    Babic, Steven; Schreiner, L. John

    2006-09-01

    In conformal radiation therapy, a high dose of radiation is given to a target volume to increase the probability of cure, and care is taken to minimize the dose to surrounding healthy tissue. The techniques used to achieve this are very complicated and the precise verification of the resulting three-dimensional (3D) dose distribution is required. Polyacrylamide gelatin (PAG) dosimeters with magnetic resonance imaging and optical computed tomography scanning provide the required 3D dosimetry with high spatial resolution. Many basic studies have characterized these chemical dosimeters that polymerize under irradiation. However, the investigation of the fundamental properties of the radiation-induced polymerization in PAG dosimeters is complicated by the presence of the background gelatin matrix. In this work, a gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters has been developed. Experiments were performed on gelatin-free dosimeters, named aqueous polyacrylamide (APA) dosimeters, containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide. The APA dosimeters were prepared with four different total monomer concentrations (2, 4, 6 and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all four dosimeters, show a continuous degree of polymerization over the dose range of 0-25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of crosslinked polymer formed at each dose. This model can be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.

  11. [Equestrian accidents in children].

    PubMed

    Giebel, G; Braun, K; Mittelmeier, W

    1993-11-01

    In a retrospective study we reviewed 262 horse riding related injuries in children younger than 16 which were treated between 1975 and 1989 at the Section of Traumatology in the Department of Surgery, University Hospital Homburg/Saar. In 155 of these accidents, detailed information was gained via a questionnaire. The typical patient profile was that of young female equestrians with little experience and little weekly riding practice, without practicing falling-exercises and warming up often using different horses. At the time of the accident only 59% were wearing a head protection. Most accidents happened in the summer months in the afternoon during leisure riding on a large familiar horse in the riding hall. Apart from the typical accidents like falling of the horse (64.9%) and falling with the horse (5.7%) accidents in handling the horse were of special significance: Kick by horse's hoof (11.8%), being stepped by horse (3.8%), horsebite (7.3%) and injuries of horse's bridle had their own pattern of injuries. Injuries of the distal parts of the upper extremity are preeminent in falling of the horse, whilst in falling with the horse head injuries and shoulder injuries are preeminent. Remarkably often injuries of kick by horse's hoof were causing sometimes even dangerous head injuries (41.6%). Overall in horse riding related injuries in childhood superficial soft tissue injuries (48.6%) and fractures (30.6%) were predominant. Fractures of the clavicle which are well known as a riding injury proved to be typical for a fall with the horse, whilst a fractured vertebra was only seen once amongst the 262 children treated. The severity of the injuries was lower than expected: In 85.1% of all the injuries only one body region was injured, 90.1% could be assigned to an injury severity score (ISS) of 1-3. Ponyriders had less severe injuries than riders of large horses. One fatal accident happened in handling a horse, in these situations preventive measures are often

  12. Thermoluminescent dosimeter measurements and analysis for LDEF experiment M0006

    NASA Technical Reports Server (NTRS)

    Stauber, Michael C.; Chang, J.; Kantorcik, T.

    1991-01-01

    Glow curve measurements are reported up to 600 C of (Thermoluminescent Dosimeter Measurement) TLD-100 (LiF) samples deployed on Long Duration Exposure Facility (LDEF) and retained as ground control. Lab exposure simulations are also reported with Co-60 radiation, low energy light ions and high energy protons in an effort to replicate the glow curves, especially the high temperature peaks observed in the LDEF TLD specimens. The evidence to date clearly shows the effect of inflight anneal on the low temperature part of the glow curve. It also shows that the high temperature part of the glow curve appears due to ion dose deposition. Initial correlations between high temperature glow peaks and effective LET of the registered dose is given.

  13. Applicability of the Sunna dosimeter for food irradiation control

    NASA Astrophysics Data System (ADS)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.; Miller, S.; Murphy, M.; McLaughlin, W. L.; Slezsák, I.; Kovács, A. I.

    2002-03-01

    The quick development concerning the commercial application of food irradiation in the USA recently resulted in growing marketing of irradiated red meat as well as irradiated fresh and dried fruits. These gamma and electron irradiation technologies require specific dosimetry systems for process control. The new version of the Sunna dosimeter has been characterized in gamma, electron and bremsstrahlung radiation fields by measuring the optically stimulated luminescence (osl) at 530 nm both below and above 1 kGy, i.e. for disinfestation and for meat irradiation purposes. No humidity and no significant dose rate effect on the green osl signal was observed. The temperature coefficient was determined from 0°C up to about 40°C and to stabilize the osl signal after irradiation a heat treatment method was introduced. Based on these investigations the Sunna 'gamma' film is a suitable candidate for dose control below and above 1 kGy for food irradiation technologies.

  14. Review of four novel dosimeters developed for use in radiotherapy

    NASA Astrophysics Data System (ADS)

    Metcalfe, P.; Quinn, A.; Loo, K.; Lerch, M.; Petasecca, M.; Wong, J.; Hardcastle, N.; Carolan, M.; McNamara, J.; Cutajar, D.; Fuduli, I.; Espinoza, A.; Porumb, C.; Rosenfeld, A.

    2013-06-01

    Centre for Medical Radiation Physics (CMRP) is a research strength at the University of Wollongong, the main research theme of this centre is to develop prototype novel radiation dosimeters. Multiple detector systems have been developed by Prof Rosenfelds' group for various radiation detector applications. This paper focuses on four current detector systems being developed and studied at CMRP. Two silicon array detectors include the magic plate and dose magnifying glass (DMG), the primary focus of these two detectors is high spatial and temporal resolution dosimetry in intensity modulated radiation therapy (IMRT) beams. The third detector discussed is the MOSkinTM which is a high spatial resolution detector based on MOSFET technology, its primary role is in vivo dosimetry. The fourth detector system discussed is BrachyView, this is a high resolution dose viewing system based on Medipix detector technology.

  15. A Radiation Dosimeter Concept for the Lunar Surface Environment

    NASA Technical Reports Server (NTRS)

    Adams, James H.; Christl, Mark J.; Watts, John; Kuznetsov, Eugeny N.; Parnell, Thomas A.; Pendleton, Geoff N.

    2007-01-01

    A novel silicon detector configuration for radiation dose measurements in an environment where solar energetic particles are of most concern is described. The dosimeter would also measure the dose from galactic cosmic rays. In the lunar environment a large range in particle flux and ionization density must be measured and converted to dose equivalent. This could be accomplished with a thick (e.g. 2mm) silicon detector segmented into cubic volume elements "voxels" followed by a second, thin monolithic silicon detector. The electronics needed to implement this detector concept include analog signal processors (ASIC) and a field programmable gate array (FPGA) for data accumulation and conversion to linear energy transfer (LET) spectra and to dose-equivalent (Sievert). Currently available commercial ASIC's and FPGA's are suitable for implementing the analog and digital systems.

  16. Solid state dosimeters used in medical physics "A review"

    NASA Astrophysics Data System (ADS)

    Azorín-Nieto, Juan

    2012-10-01

    Many solid-state detectors have been successfully used to perform the quality control and in vivo dosimetry in medical physics, both in diagnostic radiology and radiotherapy, as they have high sensitivity in a small volume; most of them do not require electrical connection and have dosimetric characteristics of interest such as: good accuracy and reproducibility, as well as a response independent of the energy of radiation, some of them. For this reason, the selection of an appropriate detector for use in medical physics must take into account the energy mass absorption coefficient relative to water for photon sources and the mass stopping power relative to water for beta emitters and electron beams in the energy range of interest in medical physics, as well as the effective atomic number of materials that constitute them. This paper presents a review of the dosimetric characteristics of the solid state dosimeters most suitable for use in medical physics.

  17. Stereotactic radiosurgery dosimetry using thermoluminescent dosimeters and radiochromic films

    NASA Astrophysics Data System (ADS)

    Ávila-Rodríguez, Miguel A.; Rodríguez-Villafuerte, Mercedes; Perches, Rodolfo Díaz

    2000-10-01

    In this work we present a protocol to measure absorbed dose distributions in stereotactic radiosurgery treatments with a linear accelerator (Linac) using thermoluminescent dosimeters (TLD) and radiochromic dye films. A Linac Philips SL-15 (6 MV X-rays), a ZD2 stereoactic system for localizing the target via computed tomography (CT), and Leibinger radiosurgery accessories will be used. A versatile spherical acrylic phantom of 16 cm diameter to measure the dose distributions has been designed. The phantom is composed of two hemispheres. On one flat side of the hemispheres an array of Harshaw/Bicron TLD-100 or a sheet of GafChromic MD-55 film will be placed. The phantom will be irradiated in three different orientations to obtain spatial dose distributions in the coronal, sagital and transverse planes. The experimental measurement will be compared with the results provided by a commercial treatment-planning system.

  18. [AOR characterization and zoning: a dosimeter for blue light].

    PubMed

    Dario, R; Uva, J; Di Lecce, V; Quarto, A

    2011-01-01

    The paper presents the results obtained thanks to an innovative experimental device for the assessment of artificial optical radiation (AOR) exposure in workplace. This . device was developed by 'Politecnico di Bari-DIASS'. The wearable personal dosimeter has three sensors: one is used for measuring head position/movement, therefore there is a color light sensor to determine the AOR and finally there is a video camera to localize sources. Our system is connected to a netbook via USB cable that allows one to obtain the real and extimated value of worker's exposure, also with "augmented reality". The aim of this paper is realizing work place safety zoning for the classifacation of not only specific dangerous areas through the analysis of overlapping information from the device. PMID:23393888

  19. Calibration results obtained with Liulin-4 type dosimeters

    NASA Astrophysics Data System (ADS)

    Dachev, Ts.; Tomov, B.; Matviichuk, Yu.; Dimitrov, Pl.; Lemaire, J.; Gregoire, Gh.; Cyamukungu, M.; Schmitz, H.; Fujitaka, K.; Uchihori, Y.; Kitamura, H.; Reitz, G.; Beaujean, R.; Petrov, V.; Shurshakov, V.; Benghin, V.; Spurny, F.

    The Mobile Radiation Exposure Control System's (Liulin-4 type) main purpose is to monitor simultaneously the doses and fluxes at 4 independent places. It can also be used for personnel dosimetry. The system consists of 4 battery-operated 256-channel dosimeters-spectrometers. We describe results obtained during the calibrations of the spectrometers at the Cyclotron facilities of the University of Louvain, Belgium and of the National Institute of Radiological Sciences-STA, Chiba, Japan with protons of energies up to 70 MeV. The angular sensitivities of the devices are studied and compared with Monte-Carlo predictions. We also present the results obtained at the HIMAC accelerator with 500 MeV/u Fe ions and at the CERN high energy radiation reference fields. Records made during airplane flights are shown and compared with the predictions of the CARI-6 model.

  20. Calibration factors for the SNOOPY NP-100 neutron dosimeter

    NASA Astrophysics Data System (ADS)

    Moscu, D. F.; McNeill, F. E.; Chase, J.

    2007-10-01

    Within CANDU nuclear power facilities, only a small fraction of workers are exposed to neutron radiation. For these individuals, roughly 4.5% of the total radiation equivalent dose is the result of exposure to neutrons. When this figure is considered across all workers receiving external exposure of any kind, only 0.25% of the total radiation equivalent dose is the result of exposure to neutrons. At many facilities, the NP-100 neutron dosimeter, manufactured by Canberra Industries Incorporated, is employed in both direct and indirect dosimetry methods. Also known as "SNOOPY", these detectors undergo calibration, which results in a calibration factor relating the neutron count rate to the ambient dose equivalent rate, using a standard Am-Be neutron source. Using measurements presented in a technical note, readings from the dosimeter for six different neutron fields in six source-detector orientations were used, to determine a calibration factor for each of these sources. The calibration factor depends on the neutron energy spectrum and the radiation weighting factor to link neutron fluence to equivalent dose. Although the neutron energy spectra measured in the CANDU workplace are quite different than that of the Am-Be calibration source, the calibration factor remains constant - within acceptable limits - regardless of the neutron source used in the calibration; for the specified calibration orientation and current radiation weighting factors. However, changing the value of the radiation weighting factors would result in changes to the calibration factor. In the event of changes to the radiation weighting factors, it will be necessary to assess whether a change to the calibration process or resulting calibration factor is warranted.

  1. Thermal drift reduction with multiple bias current for MOSFET dosimeters.

    PubMed

    Carvajal, M A; Martínez-Olmos, A; Morales, D P; Lopez-Villanueva, J A; Lallena, A M; Palma, A J

    2011-06-21

    New thermal compensation methods suitable for p-channel MOSFET (pMOS) dosimeters with the usual dose readout procedure based on a constant drain current are presented. Measuring the source-drain voltage shifts for two or three different drain currents and knowing the value of the zero-temperature coefficient drain current, I(ZTC), the thermal drift of source-drain or threshold voltages can be significantly reduced. Analytical expressions for the thermal compensation have been theoretically deduced on the basis of a linear dependence on temperature of the parameters involved. The proposed thermal modelling has been experimentally proven. These methods have been applied to a group of ten commercial pMOS transistors (3N163). The thermal coefficients of the source-drain voltage and the threshold voltage were reduced from -3.0 mV  °C(-1), in the worst case, down to -70 µV  °C(-1). This means a thermal drift of -2.4 mGy  °C(-1) for the dosimeter. When analysing the thermal drifts of all the studied transistors, in the temperature range from 19 to 36 °C, uncertainty was obtained in the threshold voltage due to a thermal drift of ±9 mGy (2 SD), a commonly acceptable value in most radiotherapy treatments. The procedures described herein provide thermal drift reduction comparable to that of other technological or numerical strategies, but can be used in a very simple and low-cost dosimetry sensor. PMID:21606552

  2. The Global Gridded Crop Model Intercomparison (GGCMI) (Invited)

    NASA Astrophysics Data System (ADS)

    Elliott, J. W.

    2013-12-01

    In 2012 AgMIP led a Global Gridded Crop Model (GGCM) Intercomparison fast-track project in coordination with the PIK-led Inter-Sectoral Impacts Model Intercomparison Project (ISI-MIP). This fast-track included 7 GGCMs and updated the state of knowledge on climate change vulnerabilities and impacts using modern global high-resolution models driven by climate model output from CMIP5. This fast-track culminated with the January 31st submission of 6 papers to a PNAS special issue. Initial results indicate the potential of global gridded crop model simulations and the need to further improve understanding of mechanisms, assumptions, and uncertainties of model design and execution; these are best addressed in a coordinated model intercomparison project at continental and global scale. In Spring 2013, we developed a new set of protocols for the next phase of the GGCMI, which will run for 3 years and include 3 overlapping stages of increasing duration: 1) Historical simulation and model evaluation 2) Analysis of model sensitivity to CTWN (carbon, temperature, water, and nitrogen) 3) Coordinated regional and global climate assessment In this talk we will summarize some key finding from the 2012 fast-track assessment and present preliminary results from Phase 2.1: Historical simulation and model evaluation. In this stage, models are being run using various observation and reanalysis-based historical weather products so that they can be evaluated over the historical period globally and in various key interest regions, so that inter-model differences can be compared against the variation induced by the choice of historical data product, and so that historical extreme events can be evaluated in a multi-model framework. The project currently includes 17 modeling groups from 11 countries, along with several other major data partners, and simulations are being performed over the Summer and Fall of 2013.

  3. Global Intercomparison of 12 Land Surface Heat Flux Estimates

    NASA Technical Reports Server (NTRS)

    Jimenez, C.; Prigent, C.; Mueller, B.; Seneviratne, S. I.; McCabe, M. F.; Wood, E. F.; Rossow, W. B.; Balsamo, G.; Betts, A. K.; Dirmeyer, P. A.; Fisher, J. B.; Jung, M.; Kanamitsu, M.; Reichle, R. H.; Reichstein, M.; Rodell, M.; Sheffield, J.; Tu, K.; Wang, K.

    2011-01-01

    A global intercomparison of 12 monthly mean land surface heat flux products for the period 1993-1995 is presented. The intercomparison includes some of the first emerging global satellite-based products (developed at Paris Observatory, Max Planck Institute for Biogeochemistry, University of California Berkeley, University of Maryland, and Princeton University) and examples of fluxes produced by reanalyses (ERA-Interim, MERRA, NCEP-DOE) and off-line land surface models (GSWP-2, GLDAS CLM/ Mosaic/Noah). An intercomparison of the global latent heat flux (Q(sub le)) annual means shows a spread of approx 20 W/sq m (all-product global average of approx 45 W/sq m). A similar spread is observed for the sensible (Q(sub h)) and net radiative (R(sub n)) fluxes. In general, the products correlate well with each other, helped by the large seasonal variability and common forcing data for some of the products. Expected spatial distributions related to the major climatic regimes and geographical features are reproduced by all products. Nevertheless, large Q(sub le)and Q(sub h) absolute differences are also observed. The fluxes were spatially averaged for 10 vegetation classes. The larger Q(sub le) differences were observed for the rain forest but, when normalized by mean fluxes, the differences were comparable to other classes. In general, the correlations between Q(sub le) and R(sub n) were higher for the satellite-based products compared with the reanalyses and off-line models. The fluxes were also averaged for 10 selected basins. The seasonality was generally well captured by all products, but large differences in the flux partitioning were observed for some products and basins.

  4. New technique to improve the accuracy of albedo neutron dosimeter evaluations

    NASA Astrophysics Data System (ADS)

    Hankins, D. E.

    The calibration factor for albedo neutron dosimeters varies greatly depending upon the energy of the neutrons in the exposure. Calibration results obtained over an eight-year period at each Lawrence Livermore National Laboratory facility where neutron exposure may occur were reviewed. A stronger relationship than expected was found between the ratio of the readings of the 9-in. to 3-in. spheres and the percent thermal. Readings from personnel and albedo badges were reviewed. The readings were consistent with the use of a calibration factor for the albedo dosimeter which varies with changes in the ratio of the personnel and albedo dosimeter TLD readings.

  5. Laboratory facilities and recommendations for the characterization of biological ultraviolet dosimeters.

    PubMed

    Bolsée, D; Webb, A R; Gillotay, D; Dörschel, B; Knuschke, P; Krins, A; Terenetskaya, I

    2000-06-01

    A laboratory facility for characterizing biological dosimeters for the measurement of UV radiation has been built and tested. The facility is based on a solar simulator, stabilized by photofeedback, and monitored by a spectroradiometer, with a versatile filter arrangement. This enables the following characteristics of the dosimeters to be ascertained: spectral response, linearity, and reciprocity; angular acceptance and response; calibration in simulated sunlight. The system has been tested on a variety of dosimeters and has the potential to be used with other radiometers, subject currently to the size of their active surface. PMID:18345205

  6. Measurement of a 200 MeV proton beam using a polyurethane dosimeter

    NASA Astrophysics Data System (ADS)

    Heard, Malcolm; Adamovics, John; Ibbott, Geoffrey

    2006-12-01

    PRESAGETM (Heuris Pharma LLC, Skillman, NJ) is a three-dimensional polyurethane dosimeter containing a leuco dye that generates a color change when irradiated. The dosimeter is solid and does not require a container to maintain its shape. The dosimeter is transparent before irradiation and the maximum absorbance of the leuco dye occurs at 633 nm which is compatible with the OCT-OPUSTM laser CT scanner (MGS Research, Inc., Madison, CT). The purpose of this study was to investigate the response of PRESAGETM to proton beam radiotherapy.

  7. New technique to improve the accuracy of albedo neutron dosimeter evaluations

    SciTech Connect

    Hankins, D.E.

    1984-01-01

    The calibration factor for albedo neutron dosimeters varies greatly depending upon the energy of the neutrons in the exposure. Calibration results obtained over an eight-year period at each Lawrence Livermore National Laboratory facility where neutron exposure may occur were reviewed. A stronger relationship than expected was found between the ratio of the readings of the 9-in. to 3-in. spheres and the percent thermal. Readings from personnel and albedo badges were reviewed. The readings were consistent with the use of a calibration factor for the albedo dosimeter which varies with changes in the ratio of the personnel and albedo dosimeter TLD readings. 2 references, 6 figures. (ACR)

  8. Radionuclide analyses of urine samples: results of an intercomparison

    NASA Astrophysics Data System (ADS)

    Dalheimer, A. R.; Beyer, D.; Günther, E. W.; Henrichs, K.

    1996-02-01

    The measurement of radioactivity concentrations in urine samples is an important tool for monitoring possible radionuclide intakes by occupationally exposed workers, especially for radionuclides emitting alpha or beta radiation. Quality assurance requires systematic intercomparisons involving all laboratories responsible for these measurements. Such analyses were performed by the German—Swiss Radiation Protection Association. The main purpose of these measurements was the specification of criteria for the acceptance of laboratories by radiation protection authorities. This contribution presents some measurement results of Th-nat, 90Sr, and 241Am in urine and discusses the implications for internal dosimetry.

  9. Slovenian-Romanian bilateral intercomparison on tritium samples.

    PubMed

    Glavič-Cindro, D; Varlam, C; Faurescu, D; Vagner, I; Logar, J Kožar

    2014-05-01

    A Slovenian laboratory from the Jožef Stefan Institute (JSI) and a Romanian laboratory from the National Research and Development Institute for Cryogenics and Isotopic Technologies (ICIT) performed bilateral intercomparisons of tritium determination in environmental samples. On the basis of the results, the measurement and analysis methods were compared. Comparability and traceability were confirmed with the results from international radioactivity proficiency test exercises organized by IAEA and NPL where both laboratories participated. New knowledge gained leads to harmonized, precise and traceable results of low level tritium environmental samples measurements. PMID:24332881

  10. An intercomparison of hydrological network-design technologies

    USGS Publications Warehouse

    Moss, M.E.; Tasker, Gary D.

    1991-01-01

    Two network-design technologies are compared by random sub-sampling of actual streamflow data. The technologies Network Analysis for Regional Information (NARI) and Network Analysis Using Generalized Least Squares (NAUGLS), have a common objective, viz. to maximize regional information within a limited budget and time horizon. The data used for intercomparison are from a network of 146 streamgauges in the central part of the USA. In general, the results for the illustrative example indicate that the NAUGLS method conveys more information than the NARI method to the network designer interested in maximizing regional information about mean annual flows with a limited budget. -Authors

  11. 49 CFR 835.11 - Obtaining Board accident reports, factual accident reports, and supporting information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Obtaining Board accident reports, factual accident... Board accident reports, factual accident reports, and supporting information. It is the responsibility... obtain Board accident reports, factual accident reports, and accompanying accident docket files....

  12. 49 CFR 835.11 - Obtaining Board accident reports, factual accident reports, and supporting information.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Obtaining Board accident reports, factual accident... Board accident reports, factual accident reports, and supporting information. It is the responsibility... obtain Board accident reports, factual accident reports, and accompanying accident docket files....

  13. Accident Flying Squad

    PubMed Central

    Snook, Roger

    1972-01-01

    This paper describes the organization, evaluation, and costing of an independently financed and operated accident flying squad. 132 accidents involving 302 casualties were attended, six deaths were prevented, medical treatment contributed to the survival of a further four, and the condition or comfort of many other casualties was improved. The calls in which survival was influenced were evenly distributed throughout the three-and-a-half-year survey and seven of the 10 so aided were over 16 and under 30 years of age, all 10 being in the working age group. The time taken to provide the service was not excessive and the expense when compared with the overall saving was very small. The scheme was seen to be equally suitable for basing on hospital or general practice or both, and working as an integrated team with the ambulance service. The use of specialized transport was found to be unnecessary. Other benefits of the scheme included use of the experience of attending accidents to ensure relevant and realistic training for emergency service personnel, and an appreciation of the effect of ambulance design on the patient. ImagesFIG. 1FIG. 4 PMID:5069642

  14. Los Alamos personnel and area criticality dosimeter systems

    SciTech Connect

    Vasilik, D.G.; Martin, R.W.

    1981-06-01

    Fissionable materials are handled and processed at the Los Alamos National Laboratory. Although the probability of a nuclear criticality accident is very remote, it must be considered. Los Alamos maintains a broad spectrum of dose assessment capabilities. This report describes the methods employed for personnel neutron, area neutron, and photon dose evaluations with passive dosimetry systems.

  15. Daily variation of radiation dose rate after the Fukushima Nuclear Accident

    NASA Astrophysics Data System (ADS)

    Yamauchi, Masatoshi

    2015-04-01

    After the radioactive contamination of the lands from the Fukushima Nuclear Power Plant accident, the radiation dose rates observed by the dosimeters often shows daily variations, at different local times at different places or time. These variations are caused by different reasons: the temperature-dependent characteristics of the dosimeter (instrumental effect), the daily convective wind that lifts up the radioactive small particle on the ground (local effect), and the daily sea-land wind that transports the radioactive small particle from highly contaminated area (regional effect). The last type is most important in understanding the internal dose by air taking. However, while very regular patterns can easily be judged as instrumental effect, variations that strongly depend on the weather conditions are not easily judged. Combining the atmospheric electric field measurement near the ground (potential gradient, PG) with the wind and weather data, some of these unclear cases can be classified into above three reasoning, which will be shown in the presentation. Thus, the PG measurement is important right after any nuclear accidents in the future.

  16. Novel composition of polymer gel dosimeters based on N-(Hydroxymethyl)acrylamide for radiation therapy

    NASA Astrophysics Data System (ADS)

    Basfar, Ahmed A.; Moftah, Belal; Rabaeh, Khalid A.; Almousa, Akram A.

    2015-07-01

    A new composition of polymer gel dosimeters is developed based on radiation induced polymerization of N-(Hydroxymethyl)acrylamide (NHMA) for radiotherapy treatment planning. The dosimeters were irradiated by 10 MV photon beam of a medical linear accelerator at a constant dose rate of 600 cGy/min with doses up to 20 Gy. The polymerization occurs and increases with increasing absorbed dose. The dose response of polymer gel dosimeters was studied using nuclear magnetic imaging (NMR) for relaxation rate (R2) of water proton. Dose rate, energy of radiation and the stability of the polymerization after irradiation were investigated. No appreciable effects of these parameters on the performance of the novel gel dosimeters were observed.

  17. Measurements of entrance surface dose using a fiber-optic dosimeter in diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Yoo, Wook Jae; Seo, Jeong Ki; Shin, Sang Hun; Han, Ki-Tek; Jeon, Dayeong; Jang, Kyoung Won; Sim, Hyeok In; Lee, Bongsoo; Park, Jang-Yeon

    2013-03-01

    In this study, a fiber-optic dosimeter (FOD) was developed to measure entrance surface dose (ESD) in diagnostic radiology. We measured the scintillating lights in order to obtain ESDs, which changed with the various exposure parameters of a digital radiography (DR) system, such as tube potential, current-time product, focus-surface distance (FSD), and field size, using the fabricated FOD system. From the experimental results, the output light signals of the FOD were similar to the ESDs of the conventional semiconductor dosimeter. In conclusion, we characterized the measured ESDs as functions of exposure parameters by using two different types of dosimeters and demonstrated that the proposed FOD using a plastic scintillating fiber and a plastic optical fiber (POF) makes it possible to measure ESDs in the energy range of diagnostic radiology. From the results of this study, it is anticipated that the FOD will be a useful dosimeter in low-energy photon applications including diagnostic radiology.

  18. NASA Crew Personal Active Dosimeters (CPADs): Leveraging Novel Terrestrial Personal Radiation Monitoring Capabilities for Space Exploration

    NASA Technical Reports Server (NTRS)

    Leitgab, Martin; Semones, Edward; Lee, Kerry

    2016-01-01

    The NASA Space Radiation Analysis Group (SRAG) is developing novel Crew Personal Active Dosimeters (CAPDs) for upcoming crewed space exploration missions and beyond. To reduce the resource footprint of the project a COTS dosimeter base is used for the development of CPADs. This base was identified from evaluations of existing COTS personal dosimeters against the concept of operations of future crewed missions and tests against detection requirements for radiation characteristic of the space environment. CPADs exploit operations efficiencies from novel features for space flight personal dosimeters such as real-time dose feedback, and autonomous measuring and data transmission capabilities. Preliminary CPAD design, results of radiation testing and aspects of operational integration will be presented.

  19. WOCE 1991 chlorofluorocarbon standard intercomparison report. Data report

    SciTech Connect

    Bullister, J.L.; Menzia, F.; Wisegarver, D.P.

    1993-07-01

    A chlorofluorocarbon (CFC) standard intercomparison study was done among ten laboratories involved in measurements of dissolved and atmospheric CFCs as part of the World Ocean Circulation Experiment (WOCE) and other programs. The goal of the study was to compare CFC calibration scales and to allow CFC data sets collected by the participating groups to be merged together more easily. One cyclinder was distributed to each participating laboratory for analysis and return to PMEL. Within the precision of the analytical techniques used at PMEL, the CFC-11 and CFC-12 concentrations in the cylinders remained uniform throughout the intercomparison exercise. The CFC-113 and carbon tetrachloride content of the cylinders remained relatively uniform in all but one of the cylinders analyzed. The CFC-11 concentrations reported by participating laboratories ranged from 258.8 to 275.6 parts-per-trillion (PPT). The reported CFC-12 concentrations ranged from 487.4 to 503.5 PPT. Two laboratories reported values for CFC-113, and only one laboratory reported a value for carbon tetrachloride. Details of the calibration techniques used by the ten participating laboratories are given in the Appendices of the report.

  20. The T-REX valley wind intercomparison project

    SciTech Connect

    Schmidli, J; Billings, B J; Burton, R; Chow, F K; De Wekker, S; Doyle, J D; Grubisic, V; Holt, T R; Jiang, Q; Lundquist, K A; Ross, A N; Sheridan, P; Vosper, S; Whiteman, C D; Wyszogrodzki, A A; Zaengl, G; Zhong, S

    2008-08-07

    An accurate simulation of the evolution of the atmospheric boundary layer is very important, as the evolution of the boundary layer sets the stage for many weather phenomena, such as deep convection. Over mountain areas the evolution of the boundary layer is particularly complex, due to the nonlinear interaction between boundary layer turbulence and thermally-induced mesoscale wind systems, such as the slope and valley winds. As the horizontal resolution of operational forecasts progresses to finer and finer resolution, more and more of the thermally-induced mesoscale wind systems can be explicitly resolved, and it is very timely to document the current state-of-the-art of mesoscale models at simulating the coupled evolution of the mountain boundary layer and the valley wind system. In this paper we present an intercomparison of valley wind simulations for an idealized valley-plain configuration using eight state-of-the-art mesoscale models with a grid spacing of 1 km. Different sets of three-dimensional simulations are used to explore the effects of varying model dynamical cores and physical parameterizations. This intercomparison project was conducted as part of the Terrain-induced Rotor Experiment (T-REX; Grubisic et al., 2008).

  1. Results of the Marine Ice Sheet Model Intercomparison Project, MISMIP

    NASA Astrophysics Data System (ADS)

    Pattyn, F.; Schoof, C.; Perichon, L.; Hindmarsh, R. C. A.; Bueler, E.; de Fleurian, B.; Durand, G.; Gagliardini, O.; Gladstone, R.; Goldberg, D.; Gudmundsson, G. H.; Huybrechts, P.; Lee, V.; Nick, F. M.; Payne, A. J.; Pollard, D.; Rybak, O.; Saito, F.; Vieli, A.

    2012-05-01

    Predictions of marine ice-sheet behaviour require models that are able to robustly simulate grounding line migration. We present results of an intercomparison exercise for marine ice-sheet models. Verification is effected by comparison with approximate analytical solutions for flux across the grounding line using simplified geometrical configurations (no lateral variations, no effects of lateral buttressing). Unique steady state grounding line positions exist for ice sheets on a downward sloping bed, while hysteresis occurs across an overdeepened bed, and stable steady state grounding line positions only occur on the downward-sloping sections. Models based on the shallow ice approximation, which does not resolve extensional stresses, do not reproduce the approximate analytical results unless appropriate parameterizations for ice flux are imposed at the grounding line. For extensional-stress resolving "shelfy stream" models, differences between model results were mainly due to the choice of spatial discretization. Moving grid methods were found to be the most accurate at capturing grounding line evolution, since they track the grounding line explicitly. Adaptive mesh refinement can further improve accuracy, including fixed grid models that generally perform poorly at coarse resolution. Fixed grid models, with nested grid representations of the grounding line, are able to generate accurate steady state positions, but can be inaccurate over transients. Only one full-Stokes model was included in the intercomparison, and consequently the accuracy of shelfy stream models as approximations of full-Stokes models remains to be determined in detail, especially during transients.

  2. Results of the Marine Ice Sheet Model Intercomparison Project, MISMIP

    NASA Astrophysics Data System (ADS)

    Pattyn, F.; Schoof, C.; Perichon, L.; Hindmarsh, R. C. A.; Bueler, E.; de Fleurian, B.; Durand, G.; Gagliardini, O.; Gladstone, R.; Goldberg, D.; Gudmundsson, G. H.; Lee, V.; Nick, F. M.; Payne, A. J.; Pollard, D.; Rybak, O.; Saito, F.; Vieli, A.

    2012-01-01

    Predictions of marine ice-sheet behaviour require models that are able to robustly simulate grounding line migration. We present results of an intercomparison exercise for marine ice-sheet models. Verification is effected by comparison with approximate analytical solutions for flux across the grounding line using simplified geometrical configurations (no lateral variations, no effects of lateral buttressing). Unique steady-state grounding line positions exist for ice sheets on a downward sloping bed, while hysteresis occurs across an overdeepened bed, and stable steady state grounding line positions only occur on the downward-sloping sections. Models based on the shallow ice approximation, which does not resolve extensional stresses, do not reproduce the approximate analytical results unless appropriate parameterizations for ice flux are imposed at the grounding line. For extensional-stress resolving "shelfy stream" models, differences between model results were mainly due to the choice of spatial discretization. Moving grid methods were found to be the most accurate at capturing grounding line evolution, since they track the grounding line explicitly. Adaptive mesh refinement can further improve accuracy, including in fixed-grid models that generally perform poorly at coarse resolution. Fixed grid models with nested grid representations of the grounding line are able to generate accurate steady-state positions, but can be inaccurate over transients. Only one full Stokes model was included in the intercomparison, and consequently the accuracy of shelfy stream models as approximations of full Stokes models remains to be determined in detail, especially during transients.

  3. An overview of sensor calibration inter-comparison and applications

    USGS Publications Warehouse

    Xiong, Xiaoxiong; Cao, Changyong; Chander, Gyanesh

    2010-01-01

    Long-term climate data records (CDR) are often constructed using observations made by multiple Earth observing sensors over a broad range of spectra and a large scale in both time and space. These sensors can be of the same or different types operated on the same or different platforms. They can be developed and built with different technologies and are likely operated over different time spans. It has been known that the uncertainty of climate models and data records depends not only on the calibration quality (accuracy and stability) of individual sensors, but also on their calibration consistency across instruments and platforms. Therefore, sensor calibration inter-comparison and validation have become increasingly demanding and will continue to play an important role for a better understanding of the science product quality. This paper provides an overview of different methodologies, which have been successfully applied for sensor calibration inter-comparison. Specific examples using different sensors, including MODIS, AVHRR, and ETM+, are presented to illustrate the implementation of these methodologies.

  4. Intercomparison exercise within a distributed-dosimetry network.

    PubMed

    Romanyukha, A; Voss, S P; Benevides, L A

    2011-03-01

    The results of an intercomparison exercise within the US Navy dosimetric network (USN-DN) are presented and discussed. The USN-DN uses a commercially available LiF:Mg,Cu,P thermoluminescent dosemeter (TLD) model Harshaw 8840/8841 and TLD reader model Harshaw 8800 manufactured by Thermo Fisher Scientific. The USN-DN consists of a single calibration facility and 16 satellite dosimetry reading facilities throughout the world with ∼ 40 model 8800 TLD readers and in excess of 350 000 TLD cards in circulation. The Naval Dosimetry Center (NDC) is the primary calibration site responsible for the distribution and calibration of all TLD cards and their associated holders. In turn, each satellite facility is assigned a subpopulation of cards, which are utilised for servicing their local customers. Consistency of the NDC calibration of 150 dosemeters (calibrated at NDC) and 27 locally calibrated remote readers was evaluated in the framework of this intercomparison. Accuracy of TLDs' calibration, performed at the NDC, was found to be <3 % throughout the entire network. Accuracy of the readers' calibration, performed with the NDC issued calibration dosemeters at remote sites, was found to be better than 4 % for most readers. The worst performance was found for reader Channel 3, which is calibrated using the thinnest chip of the Harshaw 8840/8841 dosemeter. The loss of sensitivity of this chip may be caused by time-temperature profile that has been designed for all four chips without consideration of chip thickness. PMID:21088021

  5. In situ gamma-spectrometry intercomparison exercise in Salzburg, Austria

    NASA Astrophysics Data System (ADS)

    Lettner, H.; Andrasi, A.; Hubmer, A. K.; Lovranich, E.; Steger, F.; Zombori, P.

    1996-02-01

    In situ gamma-spectrometry has become a useful method of assessing the nuclide concentrations of man-made and natural gamma-emitters in the soil. For the quality assurance of the measurements, periodically conducted intercomparison exercises are essential. Therefore exercises were organized in different European countries since 1990, the last one was conducted in Salzburg, Austria in September 1994. The participation of 27 measurement teams from all over Europe emphasizes the importance of the intercomparison. Salzburg was selected because the Province of Salzburg, Austria was among the most heavily contaminated regions outside the former USSR by the Chernobyl fallout. Two different typical sites were selected for the measurements: Site 1 was inside the urban area of Salzburg on intensively used grassland which had not been tilled since the deposition of the fallout. This site is representative for intensively used agricultural regions in the Province of Salzburg. Site 2 was in the mountainous regions of the Hohe Tauern at an elevated altitude of 1600 m, representing the agricultural soil- and contamination conditions of the Alpine regions in the Tauern. The two sites differ significantly in terms of soil characteristics, a crucial parameter for the evaluation of in situ gamma-spectra. The participants used different approaches for the evaluation of the gamma-spectra in terms of considering the depth distribution. In the paper the results from the 24 European teams are presented.

  6. IPRT polarized radiative transfer model intercomparison project - Phase A

    NASA Astrophysics Data System (ADS)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Korkin, Sergey; Ota, Yoshifumi; Labonnote, Laurent C.; Lyapustin, Alexei; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2015-10-01

    The polarization state of electromagnetic radiation scattered by atmospheric particles such as aerosols, cloud droplets, or ice crystals contains much more information about the optical and microphysical properties than the total intensity alone. For this reason an increasing number of polarimetric observations are performed from space, from the ground and from aircraft. Polarized radiative transfer models are required to interpret and analyse these measurements and to develop retrieval algorithms exploiting polarimetric observations. In the last years a large number of new codes have been developed, mostly for specific applications. Benchmark results are available for specific cases, but not for more sophisticated scenarios including polarized surface reflection and multi-layer atmospheres. The International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to fill this gap. This paper presents the results of the first phase A of the IPRT project which includes ten test cases, from simple setups with only one layer and Rayleigh scattering to rather sophisticated setups with a cloud embedded in a standard atmosphere above an ocean surface. All scenarios in the first phase A of the intercomparison project are for a one-dimensional plane-parallel model geometry. The commonly established benchmark results are available at the IPRT website.

  7. Proxy benchmarks for intercomparison of 8.2 ka simulations

    NASA Astrophysics Data System (ADS)

    Morrill, C.; Anderson, D. M.; Bauer, B. A.; Buckner, R.; Gille, E. P.; Gross, W. S.; Hartman, M.; Shah, A.

    2012-08-01

    The Paleoclimate Modelling Intercomparison Project (PMIP3) now includes the 8.2 ka event as a test of model sensitivity to North Atlantic freshwater forcing. To provide benchmarks for intercomparison, we compiled and analyzed high-resolution records spanning this event. Two previously-described anomaly patterns that emerge are cooling around the North Atlantic and drier conditions in the Northern Hemisphere tropics. Newer to this compilation are more robustly-defined wetter conditions in the Southern Hemisphere tropics and regionally-limited warming in the Southern Hemisphere. Most anomalies around the globe lasted on the order of 100 to 150 yr. More quantitative reconstructions are now available and indicate cooling of 1.0 to 1.2 °C and a ~20% decrease in precipitation in parts of Europe, as well as spatial gradients in δ18O from the high to low latitudes. Unresolved questions remain about the seasonality of the climate response to freshwater forcing and the extent to which the bipolar seesaw operated in the early Holocene.

  8. Proxy benchmarks for intercomparison of 8.2 ka simulations

    NASA Astrophysics Data System (ADS)

    Morrill, C.; Anderson, D. M.; Bauer, B. A.; Buckner, R.; Gille, E. P.; Gross, W. S.; Hartman, M.; Shah, A.

    2013-02-01

    The Paleoclimate Modelling Intercomparison Project (PMIP3) now includes the 8.2 ka event as a test of model sensitivity to North Atlantic freshwater forcing. To provide benchmarks for intercomparison, we compiled and analyzed high-resolution records spanning this event. Two previously-described anomaly patterns that emerge are cooling around the North Atlantic and drier conditions in the Northern Hemisphere tropics. Newer to this compilation are more robustly-defined wetter conditions in the Southern Hemisphere tropics and regionally-limited warming in the Southern Hemisphere. Most anomalies around the globe lasted on the order of 100 to 150 yr. More quantitative reconstructions are now available and indicate cooling of ~ 1 °C and a ~ 20% decrease in precipitation in parts of Europe as well as spatial gradients in δ18O from the high to low latitudes. Unresolved questions remain about the seasonality of the climate response to freshwater forcing and the extent to which the bipolar seesaw operated in the early Holocene.

  9. The Continual Intercomparison of Radiation Codes: Results from Phase I

    SciTech Connect

    Oreopoulos, L.; Mlawer, Eli J.; Delamere, Jennifer; Shippert, Timothy R.; Cole, Jason; Fomin, Boris; Iacono, Michael J.; Jin, Zhonghai; Li, Jiangning; Manners, James; Raisanen, Petri; Rose, Fred; Zhang, Yuanchong; Wilson, Michael J.; Rossow, William B.

    2012-01-01

    We present results from Phase I of the Continual Intercomparison of Radiation Codes (CIRC), intended as an evolving and regularly updated reference source for evaluation of radiative transfer (RT) codes used in Global Climate Models. CIRC differs from previous intercomparisons in that it relies on an observationally validated catalogue of cases. The seven CIRC Phase I baseline cases, five cloud-free, and two with overcast liquid clouds, are built around observations by the Atmospheric Radiation Measurements (ARM) program that satisfy the goals of Phase I, namely to examine radiative transfer (RT) model performance in realistic, yet not overly complex, atmospheric conditions. In addition to the seven baseline cases, additional idealized "subcases" are also examined to facilitate intrepretation of the causes of model errors. In addition to summarizing individual model performance with respect to reference line-by-line calculations and inter-model differences, we also highlight RT model behavior for conditions of doubled CO2, aspects of utilizing a spectral specification of surface albedo, and the impact of the inclusion of scattering in the thermal infrared. Our analysis suggests that RT models should work towards improving their calculation of diffuse shortwave flux, shortwave absorption, treatment of spectral surface albedo, and shortwave CO2 forcing. On the other hand, LW calculations appear to be significantly closer to the reference results. By enhancing the range of conditions under which participating codes are tested, future CIRC phases will hopefully allow even more rigorous examination of RT code performance.

  10. The Continuous Intercomparison of Radiation Codes (CIRC): Phase I Cases

    NASA Technical Reports Server (NTRS)

    Oreopoulos, Lazaros; Mlawer, Eli; Delamere, Jennifer; Shippert, Timothy; Turner, David D.; Miller, Mark A.; Minnis, Patrick; Clough, Shepard; Barker, Howard; Ellingson, Robert

    2007-01-01

    CIRC aspires to be the successor to ICRCCM (Intercomparison of Radiation Codes in Climate Models). It is envisioned as an evolving and regularly updated reference source for GCM-type radiative transfer (RT) code evaluation with the principle goal to contribute in the improvement of RT parameterizations. CIRC is jointly endorsed by DOE's Atmospheric Radiation Measurement (ARM) program and the GEWEX Radiation Panel (GRP). CIRC's goal is to provide test cases for which GCM RT algorithms should be performing at their best, i.e, well characterized clear-sky and homogeneous, overcast cloudy cases. What distinguishes CIRC from previous intercomparisons is that its pool of cases is based on observed datasets. The bulk of atmospheric and surface input as well as radiative fluxes come from ARM observations as documented in the Broadband Heating Rate Profile (BBHRP) product. BBHRP also provides reference calculations from AER's RRTM RT algorithms that can be used to select the most optimal set of cases and to provide a first-order estimate of our ability to achieve radiative flux closure given the limitations in our knowledge of the atmospheric state.

  11. [Chernobyl nuclear power plant accident and Tokaimura criticality accident].

    PubMed

    Takada, Jun

    2012-03-01

    It is clear from inspection of historical incidents that the scale of disasters in a nuclear power plant accident is quite low level overwhelmingly compared with a nuclear explosion in nuclear war. Two cities of Hiroshima and Nagasaki were destroyed by nuclear blast with about 20 kt TNT equivalent and then approximately 100,000 people have died respectively. On the other hand, the number of acute death is 30 in the Chernobyl nuclear reactor accident. In this chapter, we review health hazards and doses in two historical nuclear incidents of Chernobyl and Tokaimura criticality accident and then understand the feature of the radiation accident in peaceful utilization of nuclear power. PMID:22514916

  12. Characterization of the radiological conditions of the reactor building basement and D-rings through thermoluminescent dosimeter readings

    SciTech Connect

    Peterson, H.K.

    1988-01-01

    The accident at Three Mile Island Unit 2 (TMI-2) nuclear generating station of March 1979 released highly contaminated water to the basement and contaminated steam to other parts of the reactor building. These contaminants produced very significant and distinct radiation sources in the basement area and prevalent, lower magnitude sources throughout the remainder of the building. Radiation surveys performed during the early reactor building entries provided an abundance of data adequate for radiation protection purposes, but attempts to use this data to characterize the source terms failed. The data failed in terms of accuracy and in not being ordered to the point where it could be used successfully for computer modeling. Experience at TMI-2 showed that to obtain survey radiation readings sufficient in number and of quality for source term characterization was not consistent with the as low as reasonably achievable (ALARA) principle. One particular disadvantage of the survey data was that is was not reproducible due to inaccuracies in measurement by health physics personnel and due to instrument variations. To obtain the data required for source term characterization, strings of four-chip Panasonic personnel thermoluminescent dosimeters (TLDs) were used. With these strings, numerous radiation profiles of radiation sources throughout the reactor building were measured with an accuracy that allowed the data to be used for computer modeling and eventual source term identification and quantification.

  13. Performance of KCl:Eu2+ storage phosphor dosimeters for low dose measurements

    PubMed Central

    Li, H. Harold; Hansel, Rachael; Knutson, Nels; Yang, Deshan

    2013-01-01

    Recent research has demonstrated that europium doped potassium chloride (KCl:Eu2+) storage phosphor material has the potential to become the physical foundation of a novel and reusable dosimetry system using either film-like devices or devices similar to thermoluminescent dosimeter (TLD) chips. The purposes of this work are to quantify the performance of KCl:Eu2+ prototype dosimeters for low dose measurements and to demonstrate how it can be incorporated into clinical application for in vivo peripheral dose measurements. Pellet-style KCl:Eu2+ dosimeters, 6 mm in diameter, and 1 mm thick, were fabricated in-house for this study. The dosimeters were read using a laboratory photostimulated luminescence detection system. KCl:Eu2+ prototype storage phosphor dosimeter was capable of measuring a dose-to-water as low as 0.01 cGy from a 6 MV photon beam with a signal-to-noise ratio greater than 6. A pre-readout thermal annealing procedure enabled the dosimeter to be read within an hour post irradiation. After receiving large accumulated doses (~10 kGy), the dosimeters retained linear response in the low dose region with only a 20 percent loss of sensitivity comparing to a fresh sample (zero Gy history). The energy-dependence encountered during low dose peripheral measurements could be accounted for via a single point outside-field calibration per each beam quality. With further development the KCl:Eu2+− based dosimeter could become a versatile and durable dosimetry tool with large dynamic range (sub-cGy to 100 Gy). PMID:23735856

  14. Dose control in electron beam processing: Comparison of results from a graphite charge collector, routine dosimeters and the ISS alanine-based dosimeter

    NASA Astrophysics Data System (ADS)

    Fuochi, P. G.; Onori, S.; Casali, F.; Chirco, P.

    1993-10-01

    A 12 MeV linear accelerator is currently used for electron beam processing of power semiconductor devices for lifetime control and, on an experimental basis, for food irradiation, sludge treatment etc. In order to control the irradiation process a simple, quick and reliable method for a direct evaluation of dose and fluence in a broad electron beam has been developed. This paper presents the results obtained using a "charge collector" which measures the charge absorbed in a graphite target exposed in air. Calibration of the system with super-Fricke dosimeter and comparison of absorbed dose results obtained with plastic dosimeters and alanine pellets are discussed.

  15. Small-Field Measurements of 3D Polymer Gel Dosimeters through Optical Computed Tomography

    PubMed Central

    Shih, Cheng-Ting; Lee, Yao-Ting; Wu, Shin-Hua; Yao, Chun-Hsu; Hsieh, Bor-Tsung

    2016-01-01

    With advances in therapeutic instruments and techniques, three-dimensional dose delivery has been widely used in radiotherapy. The verification of dose distribution in a small field becomes critical because of the obvious dose gradient within the field. The study investigates the dose distributions of various field sizes by using NIPAM polymer gel dosimeter. The dosimeter consists of 5% gelatin, 5% monomers, 3% cross linkers, and 5 mM THPC. After irradiation, a 24 to 96 hour delay was applied, and the gel dosimeters were read by a cone beam optical computed tomography (optical CT) scanner. The dose distributions measured by the NIPAM gel dosimeter were compared to the outputs of the treatment planning system using gamma evaluation. For the criteria of 3%/3 mm, the pass rates for 5 × 5, 3 × 3, 2 × 2, 1 × 1, and 0.5 × 0.5 cm2 were as high as 91.7%, 90.7%, 88.2%, 74.8%, and 37.3%, respectively. For the criteria of 5%/5 mm, the gamma pass rates of the 5 × 5, 3 × 3, and 2 × 2 cm2 fields were over 99%. The NIPAM gel dosimeter provides high chemical stability. With cone-beam optical CT readouts, the NIPAM polymer gel dosimeter has potential for clinical dose verification of small-field irradiation. PMID:26974434

  16. The thermoluminescence study of epoxy based LiF:Mg,Cu,P dosimeters

    NASA Astrophysics Data System (ADS)

    Rahangdale, S. R.; Wankhede, S. P.; Kadam, Sonal; Dhabekar, Bhushan. S.; Palikundwar, U. A.; Moharil, S. V.

    2016-05-01

    The LiF:Mg,Cu,P phosphor is the most investigated phosphor in radiation dosimetry. Results on thermoluminescence of the epoxy based LiF:Mg,Cu,P dosimeters irradiated with gamma radiations are presented and compared with results of LiF:Mg,Cu,P powder. The glow curve structure of both LiF powder and dosimeter are same and only difference is found in the glow curve peak temperature. The LiF dosimeters were made from the 5012A and 5012B epoxy. The dosimeters had a mass of about 18 mg, 5.0 mm diameter and 0.5 mm thickness. The sensitivity variation of the dosimeters for exposure to 60Co gamma rays at different angles of incidence of the radiation is found to be within 4%. Its minimum detectable dose is about 3020 µGy. The epoxy based dosimeters withstand different environment and it can be used with general TL reader without need of any special design due to its small size and plane surface.

  17. Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

    SciTech Connect

    Hyer, Daniel E.; Fisher, Ryan F.; Hintenlang, David E.

    2009-05-15

    This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

  18. Preparation of polymer gel dosimeters based on less toxic monomers and gellan gum

    NASA Astrophysics Data System (ADS)

    Hiroki, A.; Sato, Y.; Nagasawa, N.; Ohta, A.; Seito, H.; Yamabayashi, H.; Yamamoto, T.; Taguchi, M.; Tamada, M.; Kojima, T.

    2013-10-01

    New polymer gel dosimeters consisting of 2-hydroxyethyl methacrylate (HEMA), triethylene glycol monoethyl ether monomethacrylate (TGMEMA), polyethylene glycol 400 dimethacrylate (9G), tetrakis (hydroxymethyl) phosphonium chloride as an antioxidant, and gellan gum as a gel matrix were prepared. They were optically analyzed by measuring absorbance to evaluate a dose response. The absorbance of the polymer gel dosimeters that were exposed to 60Co γ-rays increased with increasing dose. The dosimeters comprising HEMA and 9G showed a linear increase in absorbance in the dose range from 0 to 10 Gy. The dose response depended on the 9G concentration. For others comprising HEMA, 9G and TGMEMA, the absorbance of the polymer gel dosimeters drastically increased above a certain dose, and then leveled off up to 10 Gy. The optical variations in these polymer gel dosimeters were also induced by x-irradiation from Cyberknife radiotherapy equipment. Furthermore, the exposed region of the latter polymer gel dosimeter exhibited a thermo-responsive behavior.

  19. An investigation into the sensitivity of various albedo neutron dosimeters aimed at correcting the readings

    NASA Astrophysics Data System (ADS)

    Alekseev, A. G.; Mokrov, Yu. V.; Morozova, S. V.

    2012-03-01

    The results of an experimental determination of the sensitivity of three types of individual neutron albedo dosimeters in neutron reference fields on the basis of radionuclide sources and at the top concrete shielding of the U-70 accelerator are presented. The results show that the ratios between the responses of the albedo dosimeters designed earlier at the Joint Institute for Nuclear Research (the albedo dosimeter (AD) and the multicomponent dosimeter (MD)) and the currently used DVGN-01 dosimeter are constant within 25% in a wide range of neutron energy. This fact makes it possible to use the results of measuring the AD and MD responses obtained earlier in neutron fields of nuclear-physical installations at the Joint Institute for Nuclear Research (JINR) for the correction of DVGN-01 dosimeter measurement results to apply it to personal radiation monitoring (PRM) at these installations. The correction factors for DVGN-01 measurement results are found and recommended to be used in PRM for most JINR installations.

  20. Characterization of a Tissue-Equivalent Dosimeter based on CMOS Solid-State Photomultipliers

    NASA Astrophysics Data System (ADS)

    Johnson, Erik; Benton, Eric; Stapels, Christopher; Chrsitian, James; Jie Chen, Xiao

    Available digital dosimeters are bulky and unable to provide real-time monitoring of dose from space radiation. The complexity of space-flight design requires reliable, fault-tolerant equip-ment capable of providing real-time dosimetry during a mission, which is not feasible with the existing thermoluminescent dosimeter (TLD) technology, especially during extravehicular activity (EVA). Real-time monitoring is important for low-Earth orbiting spacecraft and inter-planetary space flight to alert the crew when Solar Particle Events (SPE) increase the particle flux of the spacecraft environment. A dosimeter-on-a-chip for personal dosimetry is comprised of a tissue-equivalent scintillator coupled to a solid-state photomultiplier (SSPM) built using CMOS technology. The radiation sensitive component of the dosimeter is coupled to analog signal processing components and a microprocessor, which can maintain processing fidelity up to 5x105 events per second. The dynamic range of the dosimeter has been verified from 1-GeV protons (0.22 keV/µm in H20) to 420 MeV/n Fe (201.1 keV/µm in H20). The dosimeter confirmed doses to within 3

  1. N-isopropylacrylamide gel dosimeter to evaluate clinical photon beam characteristics.

    PubMed

    Chiu, Chung-Yu; Tsang, Yuk-Wah; Hsieh, Bor-Tsung

    2014-08-01

    The introduction of beam intensity control concept in current radiotherapy techniques has increased treatment planning complexity. Thus, small-field dose measurement has become increasingly vital. Polymer gel dosimetry method is widely studied. It is the only dose measurement tool that provides 3D dose distribution. This study aims to use an N-isopropylacrylamide (NIPAM) gel dosimeter to conduct beam performance measurements of percentage depth dose (PDD), beam flatness, and symmetry for photon beams with field sizes of 3×3 and 4×4 cm(2). Computed tomography scans were used to readout the gel dosimeters. In the PDD measurement, the NIPAM gel dosimeter and Gafchromic™ EBT3 radiochromic film displayed high consistency in the region deeper than the build-up region. The gel dosimeter dose profile had 3% lower flatness and symmetry measurement at 5 cm depth for different fields compared with that of the Gafchromic™ EBT3 film. During gamma evaluation under 3%/3 mm dose difference/distance-to-agreement standard, the pass rates of the polymer gel dosimeter to the TPS and EBT3 film were both higher than 96%. Given that the gel is tissue equivalent, it did not exhibit the energy dependence problems of radiochromic films. Therefore, the practical use of NIPAM polymer gel dosimeters is enhanced in clinical dose verification. PMID:24836904

  2. Reference materials and intercomparison samples available from the Environmental Monitoring Systems Laboratory - Las Vegas

    SciTech Connect

    Kantor, E.J.; Laska, P.R.

    1985-06-01

    Reference materials and intercomparison samples may be obtained by laboratories involved in the analysis of environmental samples containing radioactivity, pesticides, toxic inorganic species, or toxic organic species. These reference materials and intercomparison samples are available from the US Environmental Protection Agency's Quality Assurance Division located at the Environmental Monitoring Systems Laboratory in Las Vegas (EMSL-LV). These materials are useful for incorporation into a laboratory's quality control program for the evaluation of the precision and accuracy of analytical work. Media used for radiation reference materials are pitchblende, Monazite ore, uranium mill tailings, Mancos shale, fly ash, and water spiked with radionuclides. Radioactivity intercomparison samples consist of water, milk, air, urine, and a simulated diet slurry spiked with radionuclides. Media available for toxic organic reference materials are sludge, shale oil, and rag oil, and for intercomparison samples are soil and water. Characterized fly ash, foundry sludge, and river sediment serve as reference materials for toxic inorganics, while spiked soil and water serve as intercomparison samples. Finally, spiked adipose tissue, blood plasma, urine, and water comprise the pesticide intercomparison samples, and, after the disclosure of the true pesticide compositions and concentrations of these samples, the laboratory can use the samples as reference materials. The reference materials are generally available continuously, but the intercomparison samples are distributed on a scheduled basis and in some cases only to certain laboratories. 9 tables.

  3. Validation of an "Intelligent Mouthguard" Single Event Head Impact Dosimeter.

    PubMed

    Bartsch, Adam; Samorezov, Sergey; Benzel, Edward; Miele, Vincent; Brett, Daniel

    2014-11-01

    Dating to Colonel John Paul Stapp MD in 1975, scientists have desired to measure live human head impacts with accuracy and precision. But no instrument exists to accurately and precisely quantify single head impact events. Our goal is to develop a practical single event head impact dosimeter known as "Intelligent Mouthguard" and quantify its performance on the benchtop, in vitro and in vivo. In the Intelligent Mouthguard hardware, limited gyroscope bandwidth requires an algorithm-based correction as a function of impact duration. After we apply gyroscope correction algorithm, Intelligent Mouthguard results at time of CG linear acceleration peak correlate to the Reference Hybrid III within our tested range of pulse durations and impact acceleration profiles in American football and Boxing in vitro tests: American football, IMG=1.00REF-1.1g, R2=0.99; maximum time of peak XYZ component imprecision 3.6g and 370 rad/s2; maximum time of peak azimuth and elevation imprecision 4.8° and 2.9°; maximum average XYZ component temporal imprecision 3.3g and 390 rad/s2. Boxing, IMG=1.00REF-0.9 g, R2=0.99, R2=0.98; maximum time of peak XYZ component imprecision 3.9 g and 390 rad/s2, maximum time of peak azimuth and elevation imprecision 2.9° and 2.1°; average XYZ component temporal imprecision 4.0 g and 440 rad/s2. In vivo Intelligent Mouthguard true positive head impacts from American football players and amateur boxers have temporal characteristics (first harmonic frequency from 35 Hz to 79 Hz) within our tested benchtop (first harmonic frequency<180 Hz) and in vitro (first harmonic frequency<100 Hz) ranges. Our conclusions apply only to situations where the rigid body assumption is valid, sensor-skull coupling is maintained and the ranges of tested parameters and harmonics fall within the boundaries of harmonics validated in vitro. For these situations, Intelligent Mouthguard qualifies as a single event dosimeter in American football and Boxing. PMID:26192948

  4. An investigation of a PRESAGE® in vivo dosimeter for brachytherapy

    NASA Astrophysics Data System (ADS)

    Vidovic, A. K.; Juang, T.; Meltsner, S.; Adamovics, J.; Chino, J.; Steffey, B.; Craciunescu, O.; Oldham, M.

    2014-07-01

    Determining accurate in vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm × 20 mm) tissue equivalent radiochromic dosimeter PRESAGE® in vivo (PRESAGE®-IV) is investigated. Two readout methods of the radiation induced change in optical density (OD) were investigated: (i) volume-averaged readout by spectrophotometer, and (ii) a line profile readout by 2D projection imaging utilizing a high-resolution (50 micron) telecentric optical system. Method (i) is considered the gold standard when applied to PRESAGE® in optical cuvettes. The feasibility of both methods was evaluated by comparison to standard measurements on PRESAGE® in optical cuvettes via spectrophotometer. An end-to-end feasibility study was performed by a side-by-side comparison with TLDs in an 192Ir HDR delivery. 7 and 8 Gy was delivered to PRESAGE®-IV and TLDs attached to the surface of a vaginal cylinder. Known geometry enabled direct comparison of measured dose with a commissioned treatment planning system. A high-resolution readout study under a steep dose gradient region showed 98.9% (5%/1 mm) agreement between PRESAGE®-IV and Gafchromic® EBT2 Film. Spectrometer measurements exhibited a linear dose response between 0-15 Gy with sensitivity of 0.0133 ± 0.0007 ΔOD/(Gy ṡ cm) at the 95% confidence interval. Method (ii) yielded a linear response with sensitivity of 0.0132 ± 0.0006 (ΔOD/Gy), within 2% of method (i). Method (i) has poor spatial resolution due to volume averaging. Method (ii) has higher resolution (˜1 mm) without loss of sensitivity or increased noise. Both readout methods are shown to be feasible. The end-to-end comparison revealed a 2.5% agreement between PRESAGE®-IV and treatment plan in regions of uniform high dose. PRESAGE®-IV shows promise for in vivo dose verification

  5. Rear-end accident victims. Importance of understanding the accident.

    PubMed Central

    Sehmer, J. M.

    1993-01-01

    Family physicians regularly treat victims of rear-end vehicle accidents. This article describes how taking a detailed history of the accident and understanding the significance of the physical events is helpful in understanding and anticipating patients' morbidity and clinical course. Eight questions to ask patients are suggested to help physicians understand the severity of injury. PMID:8495140

  6. Reactor Accident Consequence Code

    SciTech Connect

    2015-11-02

    MACCS1.5 performs probabilistic calculations of potential off site consequences of the atmospheric releases of radioactive material in reactor accidents. The principal phenomena considered in MACCS are atmospheric transport, environmental contamination, emergency response, long term mitigative actions based on dose projection, dose accumulation by a number of pathways including food and water ingestion, early and latent health effects, and economic costs. MACCS can be used for a variety of applications including probabilistic risk assessment (PRA) of nuclear power plants and other nuclear facilities, sensitivity studies to gain a better understanding of the parameters important to PRA, and cost benefit analysis. The time scale after the accident is divided into three phases: emergency, intermediate, and long term. The region surrounding the reactor is divided into a polar-coordinate grid, with the reactor located at the center, for the calculations. Two preprocessors, MAXGC and DOSFAC, are included. MAXGC generates the maximum allowable ground concentrations based on protective action guide (PAG) dose levels. DOSFAC generates the dose conversion data used by MACCS.

  7. Reactor Accident Consequence Code

    2015-11-02

    MACCS1.5 performs probabilistic calculations of potential off site consequences of the atmospheric releases of radioactive material in reactor accidents. The principal phenomena considered in MACCS are atmospheric transport, environmental contamination, emergency response, long term mitigative actions based on dose projection, dose accumulation by a number of pathways including food and water ingestion, early and latent health effects, and economic costs. MACCS can be used for a variety of applications including probabilistic risk assessment (PRA) ofmore » nuclear power plants and other nuclear facilities, sensitivity studies to gain a better understanding of the parameters important to PRA, and cost benefit analysis. The time scale after the accident is divided into three phases: emergency, intermediate, and long term. The region surrounding the reactor is divided into a polar-coordinate grid, with the reactor located at the center, for the calculations. Two preprocessors, MAXGC and DOSFAC, are included. MAXGC generates the maximum allowable ground concentrations based on protective action guide (PAG) dose levels. DOSFAC generates the dose conversion data used by MACCS.« less

  8. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect

    PubMed Central

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-01-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter. PMID:25618136

  9. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect.

    PubMed

    Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki

    2015-03-01

    The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter. PMID:25618136

  10. Intercomparison of MAX-DOAS NO2 retrieval algorithms

    NASA Astrophysics Data System (ADS)

    Peters, Enno; Pinardi, Gaia; Bösch, Tim; Wittrock, Folkard; Richter, Andreas; Burrows, John P.; Van Roozendael, Michel; Piters, Ankie; Wagner, Thomas; Drosoglou, Theano; Bais, Alkis; Wang, Shanshan; Saiz-Lopez, Alfonso

    2016-04-01

    Ground-based Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements are a powerful method for monitoring of atmospheric composition in an automated way. The number of instruments and sites operated has been rapidly increasing over the last years. However, integrating the measurements from all these instruments into a consistent data set necessitates careful homogenization of measurements and data retrieval procedures. For this reason, several MAX-DOAS intercomparison campaigns have been carried out in the last years. Mostly, slant columns measured by different instruments and retrieved by different software were intercompared, i.e. observed differences were potentially caused by both, the instrument and/or the retrieval. In contrast, the approach presented here is a pure intercomparison of MAX-DOAS retrievals. In total, 16 international groups and institutes working in the field of MAX-DOAS participated. The work was performed as part of the EU-funded QA4ECV project. The intercomparison exercise is based on data recorded by the IUP-Bremen MAX-DOAS instrument during the MAD-CAT campaign (Multi-Axis DOAS comparison campaign for Aerosols and Trace gases), which was carried out at the Max-Planck-Institute of Chemistry in Mainz, Germany, in summer 2013. Each group participating in the exercise presented here performed MAX-DOAS fits using their own retrieval software but common input (IUP-Bremen spectra, same cross-sections, and same fit settings). The resulting slant columns show in general an excellent agreement (correlation coefficient > 99.9%). Surprisingly, the correlation is substantially smaller when using sequential Fraunhofer reference spectra instead of a noon reference indicating that groups calculate the sequential reference differently. Further differences were found to arise from treatment of the slit function and subsequent convolution of cross-sections as well as from wavelength calibration. The results indicate overall a high

  11. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: A phantom study

    PubMed Central

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V.; Hagan, Michael; Anscher, Mitchell

    2011-01-01

    Purpose: To evaluate both the Calypso Systems’ (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal–oxide–semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters’ reading accuracy in the presence of wireless electromagnetic transponders inside a phantom.Methods: A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with∕without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with∕without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit.Results: Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum

  12. High thermoluminescent dosimeter readings outside a medical accelerator

    SciTech Connect

    Pollock, R.W.

    1985-09-01

    A doubling in personnel monitoring doses around medical accelerators has been reported when monthly film badges were changed to quarterly thermoluminescent (TL) dosimeters. One possible explanation for the inconsistent results is the response of LiF to thermal neutrons coming through the shielding around the accelerator. To test for this possibility seven pairs of TLD-100 and TLD-700 were taped to the outside of the door to a 20-MeV accelerator room and left for one month. The average net dose of the TLD-700 crystals (..gamma.. only) was 25 mrem. The TLD-100 crystals had a net response of 62 mrem, a significant over-response. Subtracting the ..gamma.. reading, the thermal neutron reading was 37 mrem. The TL relative response factor for thermal neutrons is 36. Dividing the neutron reading by the relative response factor yields a thermal neutron dose of 1 mrem. Thus the total dose was 26 mrem rather than the 62 mrem indicated by the TLD-100 crystals.

  13. Production of element correction factors for thermoluminescent dosimeters

    SciTech Connect

    Plato, P.; Miklos, J.

    1985-11-01

    Approximately 80 processors of personal dosimetry in the United States use thermoluminescent dosimeters (TLDs). Recent demands that dosimetry processors be able to measure radiation doses to within +/- 50% of the correct value have focused attention on the reproducibility of the TL elements within each TLD. The phosphors for these TLDs are manufactured by three companies. A dosimetry processor faces three options concerning the quality of the TL elements purchased; trust the supplier's quality control program, screen new TL elements and discard those that are extremely bad, or use element correction factors (ECFs). The first option results in dosimetry processors failing the +/- 50% accuracy requirement due to excessive variability among the TL elements. The second option still permits large precision errors that come close to the +/- 50% accuracy requirement. This paper advocates the third option and presents a 10-step procedure to produce ECFs. The procedure ensures that the ECFs represent only variations among the TL elements and not variations caused by stability problems with the TLD reader. Following is an example of ECF production for 3000 TLDs.

  14. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  15. Electron Beam Quality Determination Through Fricke Xylenol Gel Dosimeter

    SciTech Connect

    Petchevist, P. C. D.; Moreira, M. V.; Almeida, A. de

    2009-03-10

    According to the IAEA TRS-398 protocol, a parallel plate ionization chamber is recommended to be used in electron dosimetry. The important dosimetric parameters such as R{sub 100} and R{sub 50}, inferred from the percentage depth dose (PDD) curve, allow to obtain the electron beam average energy at the water phantom surface (material equivalent to the soft tissue). In this work, a chemical dosimeter based on the Fe(II) to Fe(III) oxidation was used to obtain the average energies from electrons beams (from nominal energies of 5, 8 and 10 MeV) and related parameters of R{sub 100}, R{sub 50} and z{sub ref}. These energies obtained through the Fricke Xylenol Gel (FXG) were compared to those with a parallel plate ionization chamber, following the cited protocol, which showed no significant differences. From these measurements one can conclude the FXG applicability for R{sub 100}, R{sub 50} and electron beam average energy determination.

  16. Characterization of power transistors as high dose dosimeters

    NASA Astrophysics Data System (ADS)

    Fuochi, P. G.; Lavalle, M.; Corda, U.; Kovacs, A.; Peimel-Stuglik, Z.; Gombia, E.

    2009-02-01

    A bipolar transistor, previously investigated as a possible radiation dosimeter and tested under industrial irradiation conditions in high-activity gamma and high-energy, high-power electron beam facilities has been subjected to stability test in order to understand its behaviour and help to improve its performances. Charge carrier lifetime was measured for several sets of transistors which were then irradiated with various doses (3-60 kGy): seven sets with 60Co gamma rays and eight with a 10 MeV electron beam. After irradiation all the transistors were measured and each set was divided into three groups: one group was left untreated, the second group was heated at 100 °C for 30 minutes and the third group was heated at 150 °C for 30 minutes, for testing the stability of the lifetime. Our data showed that heat treatment quite successfully eliminates post-irradiation changes in the response. Response measurements of the irradiated transistors, heat-treated and untreated, were carried out at room temperature over several weeks after irradiation to establish post-irradiation stability and assess if these transistors could be used for recording dose history. Calibration curves in the range 3-60 kGy for the thermally treated and untreated devices are presented. Dependence of the response of the transistors on the temperature of the measurements in the range 20-50 °C is reported.

  17. Thermoluminescent dosimeters for low dose X-ray measurements.

    PubMed

    Fernández, S Del Sol; García-Salcedo, R; Sánchez-Guzmán, D; Ramírez-Rodríguez, G; Gaona, E; de León-Alfaro, M A; Rivera-Montalvo, T

    2016-01-01

    The response of TLD-100, CaSO4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm(2) at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO4:Dy showed a linearity from 0.1 to 60 mGy. PMID:26609683

  18. A small active dosimeter for applications in space

    NASA Astrophysics Data System (ADS)

    Ritter, Birgit; Maršálek, Karel; Berger, Thomas; Burmeister, Sönke; Reitz, Günther; Heber, Bernd

    2014-06-01

    The radiation field in low Earth orbits (LEO) differs significantly from the radiation environment on Earth's surface. Exposures are by far higher and pose an additional health risk for astronauts. Continuous monitoring is therefore a necessary task in the frame of radiation protection measures. A small battery-driven active dosimeter telescope based on silicon detectors meeting the requirements for LEO applications has been developed. The instrument, the Mobile Dosimetric Telescope (MDT), is designed to measure the absorbed dose rate and the linear energy transfer (LET) spectra. From the latter the mean quality factor of the radiation field can be derived and hence an estimate of the dose equivalent as a measure of the exposure. The calibration of the device is done using radioactive isotopes and heavy ions. Fragmentation products of heavy ions are used to show the ability of the MDT to reliably detect energy depositions from high energetic nuclei. Radiation measurements inside aircraft during long distance flights, serving as field tests of the instrument, prove the good performance of the instrument.

  19. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    PubMed

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV. PMID:19128995

  20. Feasibility Study of Glass Dosimeter for In Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

    SciTech Connect

    Rah, Jeong-Eun; Oh, Do Hoon; Kim, Jong Won; Kim, Dae-Hyun; Suh, Tae-Suk; Ji, Young Hoon; Shin, Dongho; Lee, Se Byeong; Kim, Dae Yong; Park, Sung Yong

    2012-10-01

    Purpose: To evaluate the suitability of the GD-301 glass dosimeter for in vivo dose verification in proton therapy. Methods and Materials: The glass dosimeter was analyzed for its dosimetrics characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stairlike holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurements, we compared the glass dosimeter and thermoluminescent dosimeter (TLD) dose measurements using a cylindrical phantom. We investigated the feasibility of the glass dosimeter for the measurement of dose distributions near the superficial region for proton therapy plans with a varying separation between the target volume and the surface of 6 patients. Results and Discussion: Uniformity was within 1.5%. The dose-response has good linearity. Dose-rate, fading, and energy dependence were found to be within 3%. The beam profile measured using the glass dosimeter was in good agreement with the profile obtained from the ionization chamber. Depth-dose distributions in nonmodulated and modulated proton beams obtained with the glass dosimeter were estimated to be within 3%, which was lower than those with the ionization chamber. In the phantom study, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the glass dosimeter was within 5%. With in vivo dosimetry, the calculated surface doses overestimated measurements by 4%-16% using glass dosimeter and TLD. Conclusion: It is recommended that bolus be added for these clinical cases. We also believe that the glass dosimeter has considerable potential for use with in vivo patient proton dosimetry.

  1. An intercomparison exercise on technetium-99 in seaweed

    SciTech Connect

    Bates, T.H. )

    1988-01-01

    This paper reports the results of an intercomparison exercise carried out on the determination of {sup 99}Tc in Fucus vesiculosus taken from the coastline adjacent to Sellafield. This species of seaweed has a very high affinity for the radionuclide (e.g., two orders of magnitude higher than has the edible prophyra species); it presents, therefore, a potential source for a biological reference material with the highest possible specific activity. Details of the preparation and homogeneity testing before distribution of samples for analysis are described and summaries of analytical procedures used by each participant are provided. The exercise was arranged by the UK Analysts' Informal Working Group and participants comprised laboratories considered to be expert in the analysis and others who were using the opportunity to demonstrate their capability to perform this type of determination. 17 refs., 4 tabs.

  2. Intercomparison of cryogenic radiometers using silicon trap detectors

    NASA Astrophysics Data System (ADS)

    Lassila, A.; Hofer, H.; Ikonen, E.; Liedquist, L.; Stock, K. D.; Varpula, T.

    1997-02-01

    An intercomparison of cryogenic radiometers of HUT/VTT (Finland), PTB (Germany) and SP (Sweden) using silicon trap detectors was performed. Also results of monitoring of the responsivities of trap detectors over a 6 year period are presented. It was noticed that several non-idealities can undermine the agreement between results of calibrations. The non-uniformity of the responsivity of trap detectors made the results sensitive to alignment and beam size. The nonlinearity of some trap detectors was found to be large. The average relative differences in the results of the laboratories, when all known corrections are applied, are 0957-0233/8/2/003/img9 for HUT-PTB, 0957-0233/8/2/003/img10 for SP-PTB and 0957-0233/8/2/003/img11 for SP-HUT, with standard uncertainties of 0957-0233/8/2/003/img12 and 0957-0233/8/2/003/img13, respectively.

  3. Precision intercomparison of beam current monitors at CEBAF

    SciTech Connect

    Kazimi, R.; Dunham, B.; Krafft, G.A.; Legg, r.; Liang, C.; Sinclair, C.; Mamosser, J.

    1995-12-31

    The CEBAF accelerator delivers a CW electron beam at fundamental 1497 MHz, with average beam current up to 200 {mu}A. Accurate, stable nonintercepting beam current monitors are required for: setup/control, monitoring of beam current and beam losses for machine protection and personnel safety, and providing beam current information to experimental users. Fundamental frequency stainless steel RF cavities have been chosen for these beam current monitors. This paper reports on precision intercomparison between two such RF cavities, an Unser monitor, and two Faraday cups, all located in the injector area. At the low beam energy in the injector, it is straightforward to verify the high efficiency of the Faraday cups, and the Unser monitor included a wire through it to permit an absolute calibration. The cavity intensity monitors have proven capable of stable, high precision monitoring of the beam current.

  4. International intercomparison for criticality dosimetry: the case of biological dosimetry.

    PubMed

    Roy, L; Buard, V; Delbos, M; Durand, V; Paillole, N; Grégoire, E; Voisin, P

    2004-01-01

    The Institute of Radiation Protection and Nuclear Safety (IRSN) organized a biological dosimetry international intercomparison with the purpose of comparing (i) dicentrics yield produced in human lymphocytes; (ii) the gamma and neutron dose estimate according to the corresponding laboratory calibration curve. The experimental reactor SILENE was used with different configurations: bare source 4 Gy, lead shield 1 and 2 Gy and a 60Co source 2 Gy. An increasing variation of dicentric yield per cell was observed between participants when there were more damages in the samples. Doses were derived from the observed dicentric rates according to the dose-effect relationship provided by each laboratory. Differences in dicentric rate values are more important than those in the corresponding dose values. The doses obtained by the participants were found to be in agreement with the given physical dose within 20%. The evaluation of the respective gamma and neutron dose was achieved only by four laboratories, with some small variations among them. PMID:15353693

  5. Intercomparison of remote measurements of stratospheric NO and NO2

    NASA Astrophysics Data System (ADS)

    Roscoe, H. K.; Kerridge, B. J.; Pollitt, S.; Louisnard, N.; Flaud, J. M.

    1990-02-01

    During the 1982 and 1983 Balloon Intercomparison Campaigns, the vertical profile of stratospheric NO2 was measured remotely by nine instruments and that of NO by two. Total overhead columns were measured by two more instruments. Between 30 and 35 km, where measurements overlapped, agreement between NO profiles was within + or - 30 percent, which is better than the accuracies claimed by the experimenters. Between 35 and 40 km, there was similarly good agreement between NO2 profiles, but below 30 km, differences of greater than a factor of 3 were found. In the second campaign, NO2 values from most instruments agreed within their quoted errors, except that the Oxford radiometer gave much lower values; the first campaign and the column measurements show a more uniform spread of results.

  6. German aircraft accident statistics, 1930

    NASA Technical Reports Server (NTRS)

    Weitzmann, Ludwig

    1932-01-01

    The investigation of all serious accidents, involving technical defects in the airplane or engine, is undertaken by the D.V.L. in conjunction with the imperial traffic minister and other interested parties. All accidents not clearly explained in the reports are subsequently cleared up.

  7. Weather types and traffic accidents.

    PubMed

    Klaić, Z B

    2001-06-01

    Traffic accident data for the Zagreb area for the 1981-1982 period were analyzed to investigate possible relationships between the daily number of accidents and the weather conditions that occurred for the 5 consecutive days, starting two days before the particular day. In the statistical analysis of low accident days weather type classification developed by Poje was used. For the high accident days a detailed analyses of surface and radiosonde data were performed in order to identify possible front passages. A test for independence by contingency table confirmed that conditional probability of the day with small number of accidents is the highest, provided that one day after it "N" or "NW" weather types occur, while it is the smallest for "N1" and "Bc" types. For the remaining 4 days of the examined periods dependence was not statistically confirmed. However, northern ("N", "NE" and "NW") and anticyclonic ("Vc", "V4", "V3", "V2" and "mv") weather types predominated during 5-days intervals related to the days with small number of accidents. On the contrary, the weather types with cyclonic characteristics ("N1", "N2", "N3", "Bc", "Dol1" and "Dol"), that are generally accompanied by fronts, were the rarest. For 85% days with large number of accidents, which had not been caused by objective circumstances (such as poor visibility, damaged or slippery road etc.), at least one front passage was recorded during the 3-days period, starting one day before the day with large number of accidents. PMID:11787547

  8. First Responders and Criticality Accidents

    SciTech Connect

    Valerie L. Putman; Douglas M. Minnema

    2005-11-01

    Nuclear criticality accident descriptions typically include, but do not focus on, information useful to first responders. We studied these accidents, noting characteristics to help (1) first responders prepare for such an event and (2) emergency drill planners develop appropriate simulations for training. We also provide recommendations to help people prepare for such events in the future.

  9. Intercomparison Calibration Study of Terra ASTER and MODIS

    NASA Astrophysics Data System (ADS)

    Yuan, K.; Thome, K. J.; McCorkel, J.

    2014-12-01

    Calibration and validation play an essential role during the acquisition and processing of satellite data for the Earth Observing System satellites in addition to being an integral part of maintaining scientific values of archived satellite data. The Advanced Spaceborne Thermal Emission and Reflection and Radiometer (ASTER) and Moderate Resolution Imaging Spectroradiometer (MODIS) are two of five sensors onboard the Terra platform - the Earth Observing System flagship. ASTER has a swath width of 60km with 8 bands in the visible and near infrared (VNIR) and thermal infrared (TIR) spectral range with a spatial resolution of 15m (bands 1-3) and 90m (bands 10-14), respectively while MODIS has a swath width of 2300km with 36 spectral bands from visible to infrared spectral range with a spatial resolution of 250m (bands 1-2), 500m (bands 3-7), and 1km (bands 8-36). ASTER is the 'zoom' lens and MODIS is the 'keystone' instrument for Terra; they provide quantitative measurements of various earth system variables to the scientific and to the broader community. The simultaneous view of the sensors simplifies the intercomparison between them and relies on the use of the Railroad Valley Playa test site to reduce uncertainties caused by spatial heterogeneity and spectral differences in the sensors. The fact that Railroad Valley Playa is a calibration test site for ASTER ensures that ASTER was tasked at a higher rate over this area providing more scenes for the intercomparison. The study compares ASTER L1B data for the three VNIR bands reprocessed with recent calibration updates and MODIS 02 Collection 6 data products for the similar bands. No correction for geometry angle is needed and coincident 3-km by 3-km regions are used to reduce the impact of spatial heterogeneity. A correction for spectral differences between the sensors is applied based on averages of ground measurements of the test site.

  10. Field calibrations of a long-term UV dosimeter for aquatic UVB exposures.

    PubMed

    Schouten, P W; Parisi, A V; Turnbull, D J

    2008-05-29

    Various methodologies using a wide range of measurement systems have been employed previously in order to determine the amount of UV that could be incident upon various aquatic organisms in a number of different aquatic locales. Broadband meters and spectroradiometers have been employed extensively to take underwater measurements. However, these measurement campaigns are limited by the fact that radiometric equipment requires a human controller, constant power supply and regular calibrations and corrections in order to function properly. Dosimetric measurements have also been made underwater using two distinct types of dosimeter. The first type based on a synthetic chemical, like polysulphone, and the second type based on a biological matter, such as a DNA sample. The studies made using biological dosimeters have displayed very good results, however the time and skill necessary to make these types of dosimeters can outweigh their usefulness. The chemical dosimeters are easier to make and have also provided useable data, but only for short periods of exposure, usually no more than a day. Previous research has shown that Poly (2,6-dimethyl-1,4-phenylene oxide) (PPO) has excellent potential for use as a long-term underwater solar UVB dosimeter. However, there is no documented methodology on how to properly calibrate the PPO dosimeter for water-based measurements and it has yet to be trialled in an outdoors marine environment, either real or simulated. This manuscript shows that calibrations obtained in air can not be transferred to calibrations made in water, calibrations made in one type of water can be employed for another type of water, but only within a certain range of spectral transmission and calibrations made at different depths in the same water type are interchangeable. It was also discovered that changing solar zenith angle had an effect upon calibration data. This research addressed these issues by formulating and developing a calibration methodology

  11. Dual calibrated dosimeter for simultaneous measurements of erythemal and vitamin D effective solar ultraviolet radiation.

    PubMed

    Wainwright, L; Parisi, A V; Downs, N

    2016-04-01

    A miniaturized ultraviolet radiation (UV) dosimeter based on polyphenylene oxide (PPO) has been dual calibrated for both erythemal and vitamin D effective exposures (UVB 280 - 320 nm) over extended periods up to five days. Optimal human health requires a balanced amount of UVB exposure as both too much and too little have different but serious potential health consequences. Dosimetry is an established method of measuring specific UV exposures to an object or subject. PPO dosimeters have previously been used to measure the erythemally effective UV exposure. An extension of this use is to dual calibrate the miniaturized dosimeter which will also enable measurement of vitamin D effective exposures. By calibration to the erythemal and vitamin D effective action spectra, PPO dosimeters were able to record both types of biologically effective exposure as both are active within the UVB waveband. Dose response tests were conducted in each season by exposure to solar UV with the corresponding dual calibrations made for each season. The calibration provided an R(2) of 0.95-0.99 for erythemal UV and an R(2) of 0.99 for vitamin D effective UV. The successful outcome of this testing has established that PPO is suitable for use as a long term, dual calibrated dosimeter provided the film is seasonally calibrated. This enables one dosimeter to provide two sets of exposure results. The combination of dual calibration and the long term exposure potential of PPO makes the PPO dosimeter more versatile and increases the scope of UV field research on erythemal UV and vitamin D effective UV in the future. PMID:26878218

  12. SU-E-T-368: Effect of a Strong Magnetic Field On Select Radiation Dosimeters

    SciTech Connect

    Mathis, M; Wen, Z; Tailor, R; Sawakuchi, G; Flint, D; Beddar, S; Ibbott, G

    2014-06-01

    Purpose: To determine the effect of a strong magnetic field on TLD-100, OSLD (Al{sub 2}O{sub 2}:C), and PRESAGE dosimetry devices. This study will help to determine which types of dosimeters can be used for quality assurance and in-vivo dosimetry measurements in a magnetic resonance imaginglinear accelerator (MRI-linac) system. Methods: The dosimeters were separated into two categories which were either exposed or not exposed to a strong magnetic field. In each category a set of dosimeters was irradiated with 0, 2, or 6 Gy. To expose the dosimeters to a magnetic field the samples in that category were place in a Bruker small animal magnetic resonance scanner at a field strength slightly greater than 2.5 T for at least 1 hour preirradiation and at least 1 hour post-irradiation. Irradiations were performed with a 6 MV x-ray beam from a Varian TrueBeam linac with 10×10 cm{sup 2} field at a 600 MU/min dose rate. The samples that received no radiation dose were used as control detectors. Results: The readouts of the dosimeters which were not exposed to a strong magnetic field were compared with the measurements of the dosimetry devices which were exposed to a magnetic field. No significant differences (less than 2% difference) in the performance of TLD, OSLD, or PRESAGE dosimeters due to exposure to a strong magnetic field were observed. Conclusion: Exposure to a strong magnetic field before and after irradiation does not appear to change the dosimetric properties of TLD, OSLD, or PRESAGE which indicates that these dosimeters have potential for use in quality assurance and in-vivo dosimetry in a MRI-linac. We plan to further test the effect of magnetic fields on these devices by irradiating them in the presence of a magnetic fields similar to those produced by a MRI-linac system. Elekta-MD Anderson Cancer Center Research Agreement.

  13. Study of a non-diffusing radiochromic gel dosimeter for 3D radiation dose imaging

    NASA Astrophysics Data System (ADS)

    Marsden, Craig Michael

    2000-12-01

    This thesis investigates the potential of a new radiation gel dosimeter, based on nitro-blue tetrazolium (NBTZ) suspended in a gelatin mold. Unlike all Fricke based gel dosimeters this dosimeter does not suffer from diffusive loss of image stability. Images are obtained by an optical tomography method. Nitro blue tetrazolium is a common biological indicator that when irradiated in an aqueous medium undergoes reduction to a highly colored formazan, which has an absorbance maximum at 525nm. Tetrazolium is water soluble while the formazan product is insoluble. The formazan product sticks to the gelatin matrix and the dose image is maintained for three months. Methods to maximize the sensitivity of the system were evaluated. It was found that a chemical detergent, Triton X-100, in combination with sodium formate, increased the dosimeter sensitivity significantly. An initial G-value of formazan production for a dosimeter composed of 1mM NBTZ, gelatin, and water was on the order of 0.2. The addition of Triton and formate produced a G-value in excess of 5.0. The effects of NBTZ, triton, formate, and gel concentration were all investigated. All the gels provided linear dose vs. absorbance plots for doses from 0 to >100 Gy. It was determined that gel concentration had minimal if any effect on sensitivity. Sensitivity increased slightly with increasing NBTZ concentration. Triton and formate individually and together provided moderate to large increases in dosimeter sensitivity. The dosimeter described in this work can provide stable 3D radiation dose images for all modalities of radiation therapy equipment. Methods to increase sensitivity are developed and discussed.

  14. 49 CFR 195.50 - Reporting accidents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PIPELINE Annual, Accident, and Safety-Related Condition Reporting § 195.50 Reporting accidents. An accident...) Explosion or fire not intentionally set by the operator. (b) Release of 5 gallons (19 liters) or more...

  15. 49 CFR 195.50 - Reporting accidents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PIPELINE Annual, Accident, and Safety-Related Condition Reporting § 195.50 Reporting accidents. An accident...) Explosion or fire not intentionally set by the operator. (b) Release of 5 gallons (19 liters) or more...

  16. 49 CFR 195.50 - Reporting accidents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PIPELINE Annual, Accident, and Safety-Related Condition Reporting § 195.50 Reporting accidents. An accident...) Explosion or fire not intentionally set by the operator. (b) Release of 5 gallons (19 liters) or more...

  17. Industrial accidents triggered by lightning.

    PubMed

    Renni, Elisabetta; Krausmann, Elisabeth; Cozzani, Valerio

    2010-12-15

    Natural disasters can cause major accidents in chemical facilities where they can lead to the release of hazardous materials which in turn can result in fires, explosions or toxic dispersion. Lightning strikes are the most frequent cause of major accidents triggered by natural events. In order to contribute towards the development of a quantitative approach for assessing lightning risk at industrial facilities, lightning-triggered accident case histories were retrieved from the major industrial accident databases and analysed to extract information on types of vulnerable equipment, failure dynamics and damage states, as well as on the final consequences of the event. The most vulnerable category of equipment is storage tanks. Lightning damage is incurred by immediate ignition, electrical and electronic systems failure or structural damage with subsequent release. Toxic releases and tank fires tend to be the most common scenarios associated with lightning strikes. Oil, diesel and gasoline are the substances most frequently released during lightning-triggered Natech accidents. PMID:20817399

  18. Network for the Detection of Stratospheric Change (NDSC) FTIR Intercomparison at Table Mountain Facility, November 1996

    NASA Technical Reports Server (NTRS)

    Toon, G.; Goldman, A.; Walsh, C.; Bell, W.; Blavier, J. -F.; Sen, B.; Coffey, M.; Hannigan, J.; Mankin, W.

    2000-01-01

    An intercomparison of four Fourier Transform Infrared (FTIR) spectrometers, operated side by side by JPL, NCAR, and NPL groups, using two different spectral fitting algorithms, was conducted at JPL's Table Mountain Facility (TMF) during November 1996.

  19. INTERCOMPARISON STUDY OF ATMOSPHERIC MERCURY MODELS: 1. COMPARISON OF MODELS WITH SHORT-TERM MEASUREMENTS

    EPA Science Inventory

    Five regional scale models with a horizontal domain covering the European continent and its surrounding seas, one hemispheric and one global scale model participated in an atmospheric mercury modelling intercomparison study. Model-predicted concentrations in ambient air were comp...

  20. Statistical intercomparison of global climate models: A common principal component approach with application to GCM data

    SciTech Connect

    Sengupta, S.K.; Boyle, J.S.

    1993-05-01

    Variables describing atmospheric circulation and other climate parameters derived from various GCMs and obtained from observations can be represented on a spatio-temporal grid (lattice) structure. The primary objective of this paper is to explore existing as well as some new statistical methods to analyze such data structures for the purpose of model diagnostics and intercomparison from a statistical perspective. Among the several statistical methods considered here, a new method based on common principal components appears most promising for the purpose of intercomparison of spatio-temporal data structures arising in the task of model/model and model/data intercomparison. A complete strategy for such an intercomparison is outlined. The strategy includes two steps. First, the commonality of spatial structures in two (or more) fields is captured in the common principal vectors. Second, the corresponding principal components obtained as time series are then compared on the basis of similarities in their temporal evolution.

  1. Columbia Accident Investigation Board

    NASA Technical Reports Server (NTRS)

    2003-01-01

    The Columbia Accident Investigation Board gathers for a second day for its third public hearing, held in Cape Canaveral, Florida. The CAIB was set up to examine STS-107 and analyze exploratory tests. Navy Admiral Harold W. 'Hal' Gehman Jr. was designated as the Chairman of the Board. From left to right in this photo sit Board Members Steven B. Wallace, Scott Hubbard, Dr. John Logsdon, Rear Admiral Stephen Turcotte, Hal Gehman, General Duane Deal, Dr. Douglas Osheroff, and Maj. General Kenneth W. Hess. Not shown are Maj. General John Barry, Dr. James N. Hallock, Roger Tetrault, Dr. Sheila Widnall, and Dr. Sally Ride. For more information on STS-107, please see GRIN Columbia General Explanation

  2. [The radiation accident].

    PubMed

    Stögmann, W

    1988-08-26

    The reactor accident of Chernobyl in April 1986 has shown us all the dangers which are inherent ever in the peaceful use of atomic energy. The effects of exposure to ionizing radiation are dependent on biological effectiveness, on dose, on duration of exposure and on the age of the exposed person (the younger the graver). Acute ionizing radiation of the whole body leads to radiation disease or radiation syndrome of different stages of severity according to dosage. If the patient survives other consequences of ionizing radiation may arise: non-stochastic effects such as cataracts, keloid formation, fibrosis of the lungs and infertility) and stochastic effects (oncogenesis and mutagenesis). The sensitivity to ionizing radiation is especially high in childhood because of the high velocity of cell metabolism and cell growth, the large body-surface area and because their repair mechanism following radiation damage is not yet. PMID:3188527

  3. Transport aircraft accident dynamics

    NASA Technical Reports Server (NTRS)

    Cominsky, A.

    1982-01-01

    A study was carried out of 112 impact survivable jet transport aircraft accidents (world wide) of 27,700 kg (60,000 lb.) aircraft and up extending over the last 20 years. This study centered on the effect of impact and the follow-on events on aircraft structures and was confined to the approach, landing and takeoff segments of the flight. The significant characteristics, frequency of occurrence and the effect on the occupants of the above data base were studied and categorized with a view to establishing typical impact scenarios for use as a basis of verifying the effectiveness of potential safety concepts. Studies were also carried out of related subjects such as: (1) assessment of advanced materials; (2) human tolerance to impact; (3) merit functions for safety concepts; and (4) impact analysis and test methods.

  4. Intercomparison of three microwave/infrared high resolution line-by-line radiative transfer codes

    NASA Astrophysics Data System (ADS)

    Schreier, F.; Garcia, S. Gimeno; Milz, M.; Kottayil, A.; Höpfner, M.; von Clarmann, T.; Stiller, G.

    2013-05-01

    An intercomparison of three line-by-line (lbl) codes developed independently for atmospheric sounding - ARTS, GARLIC, and KOPRA - has been performed for a thermal infrared nadir sounding application assuming a HIRS-like (High resolution Infrared Radiation Sounder) setup. Radiances for the HIRS infrared channels and a set of 42 atmospheric profiles from the "Garand dataset" have been computed. Results of this intercomparison and a discussion of reasons of the observed differences are presented.

  5. TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter

    SciTech Connect

    Juang, T; Adamovics, J; Oldham, M

    2014-06-15

    Purpose: PRESAGE is a radiochromic plastic which has demonstrated strong potential for high resolution single-use 3D dosimetry. This study evaluates a new PRESAGE formulation (Presage-RU) in which the radiochromic response is reversible (the dosimeter optically clears after irradiation), enabling the potential for reusability. Methods: Presage-RU dose response and optical-clearing rates were evaluated in both small volume dosimeters (1×1×4.5cm) and a larger cylindrical dosimeter (8cm diameter, 4.5cm length). All dosimeters were allowed to fully optically clear in dark, room temperature conditions between irradiations. Dose response was determined by irradiating small volume samples from 0–8.0Gy and measuring change in optical density. The cylindrical dosimeter was irradiated with a simple 4-field box plan (parallel opposed pairs of 4cm×4cm AP-PA beams and 2cm×4cm lateral beams) to 20Gy. High resolution 3D dosimetry was achieved utilizing optical-CT readout. Readings were tracked up to 14 days to characterize optical clearing. Results: Initial irradiation yielded a response of 0.0119△OD/(Gy*cm) while two subsequent reirradiations yielded a lower but consistent response of 0.0087△OD/(Gy*cm). Strong linearity of dose response was observed for all irradiations. In the large cylindrical dosimeter, the integral dose within the high dose region exhibited an exponential decay in signal over time (halflife= 23.9 hours), with the dosimeter effectively cleared (0.04% of the initial signal) after 10 days. Subsequent irradiation resulted in 19.5% lower initial signal but demonstrated that the exponential clearing rate remained consistent. Results of additional subsequent irradiations will also be presented. Conclusion: This work introduces a new re-usable radiochromic dosimeter (Presage-RU) compatible with high resolution (sub-millimeter) 3D dosimetry. Sensitivity of the initial radiation was observed to be slightly higher than subsequent irradiations, but the

  6. The characterization of a commercial MOSFET dosimeter system for use in diagnostic x ray.

    PubMed

    Bower, M W; Hintenlang, D E

    1998-08-01

    A commercial patient dose verification system utilizing non-invasive metal oxide semiconductor field effect transistor (MOSFET) dosimeters originally designed for radiotherapy applications has been evaluated for use at diagnostic energy levels. The system features multiple dosimeters that may be used to monitor entrance or exit skin dose and intracavity doses in phantoms in real time. We have characterized both the standard MOSFET dosimeter designed for radiotherapy dose verification and a newly developed "high sensitivity" MOSFET dosimeter designed for lower dose measurements. The sensitivity, linearity, angular response, post-exposure response, and physical characteristics were evaluated. The average sensitivity (free in air, including backscatter) of the radiotherapy MOSFET dosimeters ranged from 3.55 x 10(4) mV per C kg(-1) (9.2 mV R(-1)) to 4.87 x 10(4) mV per C kg(-1) (12.6 mV R(-1)) depending on the energy of the x-ray field. The sensitivity of the "high sensitivity" MOSFET dosimeters ranged from 1.15 x 10(5) mV per C kg(-1) (29.7 mV R(-1)) to 1.38 x 10(5) mV per C kg(-1) (35.7 mV R(-1)) depending on the energy of the x-ray field. The high sensitivity dosimeters demonstrated excellent linearity at high energies (90 and 120 kVp) and acceptable linearity at lower energies (60 kVp). The angular response was significant for free-in-air exposures, as illustrated by the sensitivity differences between the two sides of the dosimeter, but was excellent for measurements within a tissue equivalent cylinder. The post-exposure drift response is a complicated but reproducible function of time. Real-time monitoring requires little if any corrections for the post-exposure drift response. The MOSFET dosimeter system brings some unique capabilities to diagnostic radiology dosimetry including small size, real-time capabilities, nondestructive measurement, good linearity, and a predictable angular response. PMID:9685076

  7. Airborne sulfur trace species intercomparison campaign: Sulfur dioxide, dimethylsulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide

    NASA Technical Reports Server (NTRS)

    Gregory, Gerald L.; Hoell, James M., Jr.; Davis, Douglas D.

    1991-01-01

    Results from an airborne intercomparison of techniques to measure tropospheric levels of sulfur trace gases are presented. The intercomparison was part of the NASA Global Tropospheric Experiment (GTE) and was conducted during the summer of 1989. The intercomparisons were conducted on the Wallops Electra aircraft during flights from Wallops Island, Virginia, and Natal, Brazil. Sulfur measurements intercompared included sulfur dioxide (SO2), dimethylsulfide (DMS), hydrogen sulfide (H2S), carbon disulfide (CS2), and carbonyl sulfide (OCS). Measurement techniques ranged from filter collection systems with post-flight analyses to mass spectrometer and gas chromatograph systems employing various methods for measuring and identifying the sulfur gases during flight. Sampling schedules for the techniques ranged from integrated collections over periods as long as 50 minutes to one- to three-minute samples every ten or fifteen minutes. Several of the techniques provided measurements of more than one sulfur gas. Instruments employing different detection principles were involved in each of the sulfur intercomparisons. Also included in the intercomparison measurement scenario were a host of supporting measurements (i.e., ozone, nitrogen oxides, carbon monoxide, total sulfur, aerosols, etc.) for purposes of: (1) interpreting results (i.e., correlation of any noted instrument disagreement with the chemical composition of the measurement environment); and (2) providing supporting chemical data to meet CITE-3 science objectives of studying ozone/sulfur photochemistry, diurnal cycles, etc. The results of the intercomparison study are briefly discussed.

  8. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    SciTech Connect

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.; Kraft, S.; Richter, C.; Zeil, K.; Pawelke, J.

    2012-05-15

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  9. FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties

    NASA Astrophysics Data System (ADS)

    De Deene, Y.; Skyt, P. S.; Hil, R.; Booth, J. T.

    2015-02-01

    Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software. A new three dimensional anthropomorphically shaped flexible dosimeter, further called ‘FlexyDos3D’, has been constructed and a new fast optical scanning method has been implemented that enables scanning of irregular shaped dosimeters. The FlexyDos3D phantom can be actuated and deformed during the actual treatment. FlexyDos3D offers the additional advantage that it is easy to fabricate, is non-toxic and can be molded in an arbitrary shape with high geometrical precision. The dosimeter formulation has been optimized in terms of dose sensitivity. The influence of the casting material and oxygen concentration has also been investigated. The radiophysical properties of this new dosimeter are discussed including stability, spatial integrity, temperature dependence of the dosimeter during radiation, readout and storage, dose rate dependence and tissue equivalence. The first authors Y De Deene and P S Skyt made an equivalent contribution to the experimental work presented in this paper.

  10. Applicability of the polyphenylene oxide film dosimeter to high UV exposures in aquatic environments.

    PubMed

    Schouten, P W; Parisi, A V; Turnbull, D J

    2009-09-01

    Previous research has proven that the Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) dosimeter is capable of receiving both in-air and underwater UV exposures that are significantly greater than those of the more commonly used polysulphone dosimeter, within a range of accuracy close to what would be expected of dosimetric measurements made in-air provided that the necessary calibrations are completed correctly by factoring in different atmospheric column ozone levels, SZA ranges, varying water turbidity and DOM levels. However, there is yet to be an investigation detailing the performance of the PPO dosimeter and its ability to measure UV in an actual field environment over an extended period of time. This research aims to bridge this gap in the knowledge by presenting a measurement campaign carried out in two real world aquatic environments and a simulated sea water environment using a batch of PPO dosimeters set at different depths and aligned to a range of different angles and geographical directions by means of attachment to a custom built dosimeter submersible float (DSF) unit over the space of a year at a sub-tropical location. Results obtained from this measurement campaign were used to compute a K(d) value for the sea water in each particular season. These K(d) values where found to be in close agreement to standalone K(d) values derived from results taken using a standard calibrated spectrometer in the same sea water. PMID:19596202

  11. Undoped and doped poly(tetraphenylbenzidine) as sensitive material for an impedimetric nitrogen dioxide gas dosimeter

    SciTech Connect

    Marr, I.; Moos, R.; Neumann, K.; Thelakkat, M.

    2014-09-29

    This article presents a nitrogen dioxide (NO{sub 2}) detecting gas dosimeter based on poly(tetraphenylbenzidine) poly(TPD) as nitrogen oxide (NO{sub x}) sensitive layer. Gas dosimeters are suitable devices to determine reliably low levels of analytes over a long period of time. During NO{sub x} exposure, the analyte molecules are accumulated irreversibly in the sensing layer of the dosimeter enhancing the conductivity of the hole conducting poly(TPD), which can be measured by impedance spectroscopy. Due to their possibility for low cost production by simple printing techniques and very good physical, photochemical, and electrochemical properties, poly(TPD)s are suitable for application in gas dosimeters operated at room temperature. We studied the effect of doping with a Co(III)-complex in combination with a conducting salt on the dosimeter behavior. Compared to the undoped material, a strong influence of the doping can be observed: the conductivity of the sensing material increases significantly, the noise of the signal decreases and an unwanted recovery of the sensor signal can be prevented, leading to a NO{sub x} detection limit <10 ppm.

  12. Development of new two-dosimeter algorithm for effective dose in ICRP Publication 103.

    PubMed

    Kim, Chan Hyeong; Cho, Sungkoo; Jeong, Jong Hwi; Bolch, Wesley E; Reece, Warren D; Poston, John W

    2011-05-01

    The two-dosimeter method, which employs one dosimeter on the chest and the other on the back, determines the effective dose with sufficient accuracy for complex or unknown irradiation geometries. The two-dosimeter method, with a suitable algorithm, neither significantly overestimates (in most cases) nor seriously underestimates the effective dose, not even for extreme exposure geometries. Recently, however, the definition of the effective dose itself was changed in ICRP Publication 103; that is, the organ and tissue configuration employed in calculations of effective dose, along with the related tissue weighting factors, was significantly modified. In the present study, therefore, a two-dosimeter algorithm was developed for the new ICRP 103 definition of effective dose. To that end, first, effective doses and personal dosimeter responses were calculated using the ICRP reference phantoms and the MCNPX code for many incident beam directions. Next, a systematic analysis of the calculated values was performed to determine an optimal algorithm. Finally, the developed algorithm was tested by applying it to beam irradiation geometries specifically selected as extreme exposure geometries, and the results were compared with those for the previous algorithm that had been developed for the effective dose given in ICRP Publication 60. PMID:21451315

  13. Photofission Analysis for Fissile Dosimeters Dedicated to Reactor Pressure Vessel Surveillance

    NASA Astrophysics Data System (ADS)

    Bourganel, Stéphane; Faucher, Margaux; Thiollay, Nicolas

    2016-02-01

    Fissile dosimeters are commonly used in reactor pressure vessel surveillance programs. In this paper, the photofission contribution is analyzed for in-vessel 237Np and 238U fissile dosimeters in French PWR. The aim is to reassess this contribution using recent tools (the TRIPOLI-4 Monte Carlo code) and latest nuclear data (JEFF3.1.1 and ENDF/B-VII nuclear libraries). To be as exhaustive as possible, this study is carried out for different configurations of fissile dosimeters, irradiated inside different kinds of PWR: 900 MWe, 1300 MWe, and 1450 MWe. Calculation of photofission rate in dosimeters does not present a major problem using the TRIPOLI-4® Monte Carlo code and the coupled neutron-photon simulation mode. However, preliminary studies were necessary to identify the origin of photons responsible of photofissions in dosimeters in relation to the photofission threshold reaction (around 5 MeV). It appears that the main contribution of high enough energy photons generating photofissions is the neutron inelastic scattering in stainless steel reactor structures. By contrast, 137Cs activity calculation is not an easy task since photofission yield data are known with high uncertainty.

  14. Eliminating the dose-rate effect in a radiochromic silicone-based 3D dosimeter

    NASA Astrophysics Data System (ADS)

    Høye, E. M.; Balling, P.; Yates, E. S.; Muren, L. P.; Petersen, J. B. B.; Skyt, P. S.

    2015-07-01

    Comprehensive dose verification, such as 3D dosimetry, may be required for safe introduction and use of advanced treatment modalities in radiotherapy. A radiochromic silicone-based 3D dosimetry system has recently been suggested, though its clinical use has so far been limited by a considerable dose-rate dependency of the dose response. In this study we have investigated the dose-rate dependency with respect to the chemical composition of the dosimeter. We found that this dependency was reduced with increasing dye concentration, and the dose response was observed to be identical for dosimeters irradiated with 2 and 6 Gy min-1 at concentrations of 0.26% (w/w) dye and 1% (w/w) dye solvent. Furthermore, for the optimized dosimeter formulation, no dose-rate effect was observed due to the attenuation of the beam fluence with depth. However, the temporal stability of the dose response decreased with dye concentration; the response was reduced by (62  ±  1)% within approximately 20 h upon irradiation, at the optimal chemical composition and storage at room temperature. In conclusion, this study presents a chemical composition for a dose-rate independent silicone dosimeter which has considerably improved the clinical applicability of such dosimeters, but at the cost of a decreased stability.

  15. [Hidden statistics of traffic accidents].

    PubMed

    Nordentoft, E L; Larsen, C F; Jørgensen, H R

    1989-10-23

    Only 19% of the 3,071 injured persons who were treated in the casualty department of Odense Hospital following traffic accidents in 1987 could be found again in the police registers of traffic accidents from the same region. All of the registrations from the police registers from the central region could be found again in the casualty department. In 1971, the corresponding coverage was 36%. The degree of coverage is particularly low for single bicycle accidents, other bicycle accidents, other single accidents and the hours immediately after midnight. Considerable disagreement exists concerning registration of the use of safety belts and crash helmets. In Odense, the municipal road authorities utilize the localization of the accidents reported by the casualty department. The decrease in the degree of coverage is due mainly to an increasing proportion of bicycle accidents. Where casualties require admission to hospital, the coverage is approximately 75%. This has remained unchanged throughout the years and it is therefore suggested that this proportion should be employed as indicator of the effect of the majority of prophylactic measures. In addition, proposals are made for simplification of the police registration forms. PMID:2588362

  16. A review of criticality accidents

    SciTech Connect

    Stratton, W R; Smith, D R

    1989-03-01

    Criticality accidents and the characteristics of prompt power excursions are discussed. Forty-one accidental power transients are reviewed. In each case where available, enough detail is given to help visualize the physical situation, the cause or causes of the accident, the history and characteristics of the transient, the energy release, and the consequences, if any, to personnel and property. Excursions associated with large power reactors are not included in this study, except that some information on the major accident at the Chernobyl reactor in April 1986 is provided in the Appendix. 67 refs., 21 figs., 2 tabs.

  17. [Prevention of bicycle accidents].

    PubMed

    Zwipp, H; Barthel, P; Bönninger, J; Bürkle, H; Hagemeister, C; Hannawald, L; Huhn, R; Kühn, M; Liers, H; Maier, R; Otte, D; Prokop, G; Seeck, A; Sturm, J; Unger, T

    2015-04-01

    For a very precise analysis of all injured bicyclists in Germany it would be important to have definitions for "severely injured", "seriously injured" and "critically injured". By this, e.g., two-thirds of surgically treated bicyclists who are not registered by the police could become available for a general analysis. Elderly bicyclists (> 60 years) are a minority (10 %) but represent a majority (50 %) of all fatalities. They profit most by wearing a helmet and would be less injured by using special bicycle bags, switching on their hearing aids and following all traffic rules. E-bikes are used more and more (145 % more in 2012 vs. 2011) with 600,000 at the end of 2011 and are increasingly involved in accidents but still have a lack of legislation. So even for pedelecs 45 with 500 W and a possible speed of 45 km/h there is still no legislative demand for the use of a protecting helmet. 96 % of all injured cyclists in Germany had more than 0.5 ‰ alcohol in their blood, 86 % more than 1.1 ‰ and 59 % more than 1.7 ‰. Fatalities are seen in 24.2 % of cases without any collision partner. Therefore the ADFC calls for a limit of 1.1 ‰. Some virtual studies conclude that integrated sensors in bicycle helmets which would interact with sensors in cars could prevent collisions or reduce the severity of injury by stopping the cars automatically. Integrated sensors in cars with opening angles of 180° enable about 93 % of all bicyclists to be detected leading to a high rate of injury avoidance and/or mitigation. Hanging lamps reduce with 35 % significantly bicycle accidents for children, traffic education for children and special trainings for elderly bicyclists are also recommended as prevention tools. As long as helmet use for bicyclists in Germany rates only 9 % on average and legislative orders for using a helmet will not be in force in the near future, coming up campaigns seem to be necessary to be promoted by the Deutscher

  18. Investigation on Tissue Equivalent Normoxic Polymer Gel Dosimeter using In-house Laser CT scanning system

    NASA Astrophysics Data System (ADS)

    Senthil Kumar, D.; Jebaseelan Samuel, E. James

    2010-11-01

    Optical Computed Tomography has wide applications in the treatment of cancer. In continuation of this, an in-house Laser CT scanner has been built for "3D gel dosimetry". The Laser CT (LCT) scanner plays a major for Gel dosimeter or phantom readout and in clinical radiation therapy as a 3-Dimensional Radiation Dosimetry. A gel dosimeter which absorbs dose in a tissue-equivalent manner and allows the measurement of spatial distribution of the deposited dose is required. The normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When laser passes through this gel phantom, absorption and scattering takes place and combined to attenuation. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by means of a sensor. Reconstruction using Mat Lab algorithm provides 3D dose distribution.

  19. A multi-sensor dosimeter for brachytherapy based on radioluminescent fiber sensors

    NASA Astrophysics Data System (ADS)

    Correia, A.; Chiquita, S.; Hussain, N. Sooraj; Pirraco, Rui; Rosa, C. C.

    2013-05-01

    High-precision dosimeters are needed in brachytherapy treatments to ensure safe operation and adequate working conditions, to assess the correspondence between treatment planning and dose delivery, as well as to monitor the radiation dose received by patients. In this paper we present the development of a multi-sensor dosimeter platform targeted for brachytherapy environments. The performance of different scintillating materials response is assessed. The emission bands of most common scintillator materials used in ionizing radiation detection are typically below 550 nm, thus they may be prone to stem effect response. To avoid this effect we propose the use of scintillators with longer wavelength emission. Samples of neodymium doped glasses are evaluated as new infrared radioluminescent scintillators for real-time dosimeters, namely lithium lead boron silver (LLB4Ag) and lithium bismuth boron silver (LBiB4Ag) glasses. Their response is compared with the response of organic scintillator BCF-60 with a 530nm response.

  20. Radio-physical properties of micelle leucodye 3D integrating gel dosimeters

    NASA Astrophysics Data System (ADS)

    Vandecasteele, J.; Ghysel, S.; Baete, S. H.; De Deene, Y.

    2011-02-01

    Recently, novel radiochromic leucodye micelle hydrogel dosimeters were introduced in the literature. In these studies, gel measured electron depth dose profiles were compared with ion chamber depth dose data, from which it was concluded that leucocrystal violet-type dosimeters were independent of dose rate. Similar conclusions were drawn for leucomalachite green-type dosimeters, only after pre-irradiating the samples to a homogeneous radiation dose. However, in our extensive study of the radio-physical properties of leucocrystal violet- and leucomalachite green-type dosimeters, a significant dose rate dependence was found. For a dose rate variation between 50 and 400 cGy\\,min^{-1}, a maximum difference of 75% was found in optical dose sensitivity for the leucomalachite green-type dosimeter. Furthermore, the measured optical dose sensitivity of the leucomalachite green-type dosimeter was four times lower than the value previously reported in the literature. For the leucocrystal violet-type dosimeter, a maximum difference in optical dose sensitivity of 55% was found between 50 and 400 cGy\\,min^{-1}. A modified composition of the leucomalachite green-type dosimeter is proposed. This dosimeter is composed of gelatin, sodium dodecyl sulfate, chloroform, trichloroacetic acid and leucomalachite green. The optical dose sensitivity amounted to 4.375 \\times 10^{-5} \\,cm^{-1}\\; cGy^{-1} (dose rate 400 cGy\\,min^{-1}). No energy dependence for photon energies between 6 and 18 MV was found. No temperature dependence during readout was found notwithstanding a temperature dependence during irradiation of 1.90 cGy °C-1 increase on a total dose of 100 cGy. The novel gel dosimeter formulation exhibits an improved spatial stability (2.45 \\times 10^{-7} \\,cm^{2}\\; s^{-1} (= 0.088 mm^2 \\; h^{-1})) and good water/soft tissue equivalence. Nevertheless, the novel formulation was also found to have a significant, albeit reduced, dose rate dependence, as a maximum difference of 33

  1. The study of N-isopropylacrylamide gel dosimeter doped iodinated contrast agents

    NASA Astrophysics Data System (ADS)

    Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Hsieh, B. T.

    2013-06-01

    Low toxicity of N-isopropylacrylamide (NIPAM) dosimeter was doped with clinical iodinated contrast medium agents(Iobitridol (Xenetix® 350) and organically bound iodine (Conray® 60) as radiation sensitizers; The suitable gel dosimeter preparation formula in this research was 5 w/w% gelatin, 5 w/w% N-isopropylacrylamide, 3 w/w% N,N-methylene-bis-acrylamide, and 5 mM Tetrakis phosphonium chloride. The spiral CT was irradiator, and 120 kVp was the operating tube voltage. The maximum radiation dose was 0.6 Gy, and optical CT was the gel measurement device used. The results showed SERs with the addition of radiosensitizers were 10.70 (Xenetix® 350) and 9.67 (Conray® 60), respectively. Thus, the polymerized gel dosimeter could be used in the efficacy evaluation of low-energy and low-radiation dose.

  2. Thermal neutron response of the Li 2B 4O 7:Cu TL dosimeter

    NASA Astrophysics Data System (ADS)

    Gauld, I. C.; Harvey, J. W.; Kennett, T. J.; Prestwich, W. V.

    1986-10-01

    A measurement of the thermal neutron response of the Li 2B 4O 7:Cu TLD has been conducted. The results obtained using the Panasonic UD-806 dosimeter and UD-854A holder yield a free-in-air response of 3.3±0.1 R 60Co equivalent per mSv of thermal neutrons. A thermal neutron response of over 7 R 60Co equivalent per mSv was observed when the dosimeter was irradiated on water phantoms. The high sensitivity may result in a substantial overestimate of the gamma dose equivalent if the TLD is used in a mixed neutron and gamma environment of unknown ratio. Measurements of the Li 2B 4O 7:Cu glow curve, TL saturation curve and the thermal neutron response dependence of the dosimeter filtration thickness are also presented.

  3. Response of aqueous dichromate and nanoclay dichromate gel dosimeters to carbon ion irradiation

    NASA Astrophysics Data System (ADS)

    Maeyama, T.; Fukunishi, N.; Ishikawa, K. L.; Fukasaku, K.; Furuta, T.; Takagi, S.; Noda, S.; Himeno, R.; Fukuda, S.

    2013-06-01

    We have recently reported the significant reduction of radiation product diffusion by the incorporation of clay nanoparticles into dichromate gel (DCG) dosimeters. In this work, we investigate the influence of the nanoclay addition and gelation on the MRI R1 (1/T1) image response of the dichromate dosimeter to the therapeutic carbon ion beam (12C6+ 290 MeV/u). The MRI R1 distribution in the aqueous dichromate solution well reproduces physical dose-depth distribution with a high linear-energy-transfer (LET) efficiency. The nanoclay DCG dosimeters, on the other hand, exhibit composition-dependent LET efficiency degradation, while a sharp Bragg peak can still be detected. These results indicate that the nanocomposite gel addition may induce change in the radiation-induced reaction mechanism.

  4. Improving the Success Rate of Delivering Annual Occupational Dosimetry Reports to Persons Issued Temporary External Dosimeters

    SciTech Connect

    Mallett, Michael Wesley

    2014-09-09

    Workers who are not routinely monitored for occupational radiation exposure at LANL may be issued temporary dosimeters in the field. Per 10CFR835 and DOE O 231.1A, the Laboratory's radiation protection program is responsible for reporting these results to the worker at the end of the year. To do so, the identity of the worker and their mailing address must be recorded by the delegated person at the time the dosimeter is issued. Historically, this data has not been consistently captured. A new online application was developed to record the issue of temporary dosimeters. The process flow of the application was structured such that: 1) the worker must be uniquely identified in the Lab's HR database, and 2) the mailing address of record is verified live time via a commercial web service, for the transaction to be completed. A COPQ savings (Type B1) of $96K/year is demonstrated for the new application.

  5. Considerations concerning the use of counting active personal dosimeters in pulsed fields of ionising radiation.

    PubMed

    Ambrosi, Peter; Borowski, Markus; Iwatschenko, Michael

    2010-06-01

    Active personal electronic dosimeters (APDs) exhibit limitations in pulsed radiation fields, which cannot be overcome without the use of new detection technology. As an interim solution, this paper proposes a method by which some conventional dosimeters can be operated in a way such that, based on the basic knowledge about the pulsed radiation field, any dosimetric failure of the dosimeter is signalised by the instrument itself. This method is not applicable to all combinations of APD and pulsed radiation field. The necessary requirements for the APD and for the parameters of the pulsed radiation field are given in the paper. Up to now, all such requirements for APDs have not been tested or verified in a type test. The suitability of the method is verified for the use of one APD used in two clinical pulsed fields. PMID:20083488

  6. Underreporting of maritime accidents to vessel accident databases.

    PubMed

    Hassel, Martin; Asbjørnslett, Bjørn Egil; Hole, Lars Petter

    2011-11-01

    Underreporting of maritime accidents is a problem not only for authorities trying to improve maritime safety through legislation, but also to risk management companies and other entities using maritime casualty statistics in risk and accident analysis. This study collected and compared casualty data from 01.01.2005 to 31.12.2009, from IHS Fairplay and the maritime authorities from a set of nations. The data was compared to find common records, and estimation of the true number of occurred accidents was performed using conditional probability given positive dependency between data sources, several variations of the capture-recapture method, calculation of best case scenario assuming perfect reporting, and scaling up a subset of casualty information from a marine insurance statistics database. The estimated upper limit reporting performance for the selected flag states ranged from 14% to 74%, while the corresponding estimated coverage of IHS Fairplay ranges from 4% to 62%. On average the study results document that the number of unreported accidents makes up roughly 50% of all occurred accidents. Even in a best case scenario, only a few flag states come close to perfect reporting (94%). The considerable scope of underreporting uncovered in the study, indicates that users of statistical vessel accident data should assume a certain degree of underreporting, and adjust their analyses accordingly. Whether to use correction factors, a safety margin, or rely on expert judgment, should be decided on a case by case basis. PMID:21819835

  7. FACTORS AFFECTING THE USE OF CAF2:MN THERMOLUMINESCENT DOSIMETERS FOR LOW-LEVEL ENVIRONMENTAL RADIATION MONITORING

    EPA Science Inventory

    An investigation was made of factors affecting the use of commercially-produced CaF2:Mn thermoluminescent dosimeters for low level environmental radiation monitoring. Calibration factors and self-dosing rates were quantified for 150 thermoluminescent dosimeters. Laboratory studie...

  8. SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

    SciTech Connect

    Gawad, M Abdel; Elgohary, M; Hassaan, M; Emam, M; Desouky, O; Eldib, A; Ma, C

    2015-06-15

    Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric

  9. Method for correcting for isotope burn-in effects in fission neutron dosimeters

    DOEpatents

    Gold, Raymond; McElroy, William N.

    1988-01-01

    A method is described for correcting for effect of isotope burn-in in fission neutron dosimeters. Two quantities are measured in order to quantify the "burn-in" contribution, namely P.sub.Z',A', the amount of (Z', A') isotope that is burned-in, and F.sub.Z', A', the fissions per unit volume produced in the (Z', A') isotope. To measure P.sub.Z', A', two solid state track recorder fission deposits are prepared from the very same material that comprises the fission neutron dosimeter, and the mass and mass density are measured. One of these deposits is exposed along with the fission neutron dosimeter, whereas the second deposit is subsequently used for observation of background. P.sub.Z', A' is then determined by conducting a second irradiation, wherein both the irradiated and unirradiated fission deposits are used in solid state track recorder dosimeters for observation of the absolute number of fissions per unit volume. The difference between the latter determines P.sub.Z', A' since the thermal neutron cross section is known. F.sub.Z', A' is obtained by using a fission neutron dosimeter for this specific isotope, which is exposed along with the original threshold fission neutron dosimeter to experience the same neutron flux-time history at the same location. In order to determine the fissions per unit volume produced in the isotope (Z', A') as it ingrows during the irradiation, B.sub.Z', A', from these observations, the neutron field must generally be either time independent or a separable function of time t and neutron energy E.

  10. Miniature personal electronic UVR dosimeter with erythema response and time-stamped readings in a wristwatch.

    PubMed

    Heydenreich, Jakob; Wulf, Hans Christian

    2005-01-01

    Personal ultraviolet radiation (UVR) dosimetry is important because sunlight is the most important risk factor for skin cancer and a risk factor for some eye diseases and immunosuppression and related disorders. Integrating devices, such as polysulphone film dosimeters, are generally used. To measure the exact dose at specific times, we have developed a personal electronic UVR dosimeter that makes time-stamped measurements. It has a sensor with an erythema action spectrum response and a linear sensitivity (dose-response) with no offset. The sensor has cosine response, and the dosimeter can cope with environmental conditions such as rain, temperature and dirt. It can be programmed to measure with different time intervals and save the average of a specified number of measurements in the memory that can store 32 000 time-stamped measurements. It is small (36 x 28 x 13 mm), weighs 14 g and can work for 4 months without maintenance. It is worn on the wrist, is equipped with a watch showing the time and may thus be used in large-scale studies. The sensitivity can change by 10% due to temperature changes from -5 to 40 degrees C. The UVR dosimeter sensitivity is 0.09 standard erythema doses (SED)/h and the difference in total received dose during 7 days between a Solar Light 501 UV-Biometer (186 SED) and our UVR dosimeter was 3% and the median difference in daily total dose was 2.2%. The dosimeter provides unique possibilities. Examples of personal UVR measurements, data calculations and how they can be interpreted are given. PMID:15850424

  11. Direct and pulsed current annealing of p-MOSFET based dosimeter: the "MOSkin".

    PubMed

    Alshaikh, Sami; Carolan, Martin; Petasecca, Marco; Lerch, Michael; Metcalfe, Peter; Rosenfeld, Anatoly

    2014-06-01

    Contemporary radiation therapy (RT) is complicated and requires sophisticated real-time quality assurance (QA). While 3D real-time dosimetry is most preferable in RT, it is currently not fully realised. A small, easy to use and inexpensive point dosimeter with real-time and in vivo capabilities is an option for routine QA. Such a dosimeter is essential for skin, in vivo or interface dosimetry in phantoms for treatment plan verification. The metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector is one of the best choices for these purposes, however, the MOSFETs sensitivity and its signal stability degrade after essential irradiation which limits its lifespan. The accumulation of positive charge on the gate oxide and the creation of interface traps near the silicon-silicon dioxide layer is the primary physical phenomena responsible for this degradation. The aim of this study is to investigate MOSFET dosimeter recovery using two proposed annealing techniques: direct current (DC) and pulsed current (PC), both based on hot charged carrier injection into the gate oxide of the p-MOSFET dosimeter. The investigated MOSFETs were reused multiple times using an irradiation-annealing cycle. The effect of the current-annealing parameters was investigated for the dosimetric characteristics of the recovered MOSFET dosimeters such as linearity, sensitivity and initial threshold voltage. Both annealing techniques demonstrated excellent results in terms of maintaining a stable response, linearity and sensitivity of the MOSFET dosimeter. However, PC annealing is more preferable than DC annealing as it offers better dose response linearity of the reused MOSFET and has a very short annealing time. PMID:24648245

  12. The Neutron Energy Response of the Panasonic Model 809 Personnel Dosimeter

    SciTech Connect

    Frederick Cummings

    2010-04-01

    In 2010, the U.S. Department of Energy will adopt a new set of radiation weighting factors and quality factors to be consistent with values recommended by the International Commission on Radiological Protection. The change will affect the magnitude of occupational exposure assigned to radiation workers exposed to neutron radiation. Understanding the energy response of the dosimeter and the effect of the new quantities is critical to accurately ensuring that occupational exposure remains below the established regulatory limits. Therefore, the factors used to interpret dosimeter readings must be re-evaluated for each irradiation field over the range of neutron energies in which the dosimeter is used. This paper describes one method of determining the neutron response of the dosimeter. A Monte Carlo approach was used to model the energy response of the Panasonic Model 809 dosimeter over the range of energies from 1.0 x 10^-8 to 20 MeV. The response, normalized to the response at 2.1 MeV, ranged from approximately 0.5 at 20 MeV to approximately 26 at 1 eV. The response was then divided at each energy by the appropriate dose conversion coefficient to determine the dose response of the dosimeter. The dose responses, normalized to the response at 2.1 MeV, ranged from approximately 0.4 at 20 MeV to 765 at 1 eV. Dose conversion factors were determined for various reference neutron spectra and plotted on the dose response curve. Good agreement was observed except for the case of D2Omoderated 252Cf.

  13. The energy dependence of lithium formate and alanine EPR dosimeters for medium energy x rays

    SciTech Connect

    Waldeland, Einar; Hole, Eli Olaug; Sagstuen, Einar; Malinen, Eirik

    2010-07-15

    Purpose: To perform a systematic investigation of the energy dependence of alanine and lilthium formate EPR dosimeters for medium energy x rays. Methods: Lithium formate and alanine EPR dosimeters were exposed to eight different x-ray beam qualities, with nominal potentials ranging from 50 to 200 kV. Following ionometry based on standards of absorbed dose to water, the dosimeters were given two different doses of approximately 3 and 6 Gy for each radiation quality, with three dosimeters for each dose. A reference series was also irradiated to three different dose levels at a {sup 60}Co unit. The dose to water energy response, that is, the dosimeter reading per absorbed dose to water relative to that for {sup 60}Co {gamma}-rays, was estimated for each beam quality. In addition, the energy response was calculated by Monte Carlo simulations and compared to the experimental energy response. Results: The experimental energy response estimates ranged from 0.89 to 0.94 and from 0.68 to 0.90 for lithium formate and alanine, respectively. The uncertainties in the experimental energy response estimates were typically 3%. The relative effectiveness, that is, the ratio of the experimental energy response to that following Monte Carlo simulations was, on average, 0.96 and 0.94 for lithium formate and alanine, respectively. Conclusions: This work shows that lithium formate dosimeters are less dependent on x-ray energy than alanine. Furthermore, as the relative effectiveness for both lithium formate and alanine were systematically less than unity, the yield of radiation-induced radicals is decreased following x-irradiation compared to irradiation with {sup 60}Co {gamma}-rays.

  14. Response of an FBX dosimeter to high LET 7Li and 12C ions

    NASA Astrophysics Data System (ADS)

    Bhat, N. N.; Choudhary, D.; Sarma, A.; Gupta, B. L.; Siddappa, K.

    2003-12-01

    We have carried out systematic studies on the response of ferrous sulphate-benzoic acid-xylenol orange (FBX)—a highly sensitive chemical dosimeter in liquid form to accelerated charged particles of different LET. Dosimeters were exposed in the form of thin layers to graded fluence of 7Li ion beam with three different energies Viz, 46, 38 and 27 MeV corresponding to average LETs of 6.3, 7.5 and 11 eV Å -1 and 12C ion beam with energy 45.6 MeV corresponding to average LET of 52.5 eV Å -1. From the investigations, the corresponding G(Fe +3) values were found to be (51.7±1.3)×10 -7, (35.4±0.7)×10 -7, (19.3±0.6)×10 -7 and (8.4±0.1)×10 -7 mol J -1, respectively. For gamma radiation, with estimated LET of 0.02 eV Å -1, G(Fe +3) value was observed to be (56.1±0.4)×10 -7 mol J -1. Clearly, G(Fe +3) values were found to decrease with increasing LET of the particle beam. However, the dosimeter showed no dependence on LET up to about 6 eV Å -1 unlike the Fricke dosimeter. The results confirm the response of FBX dosimeter is non-linear for doses exceeding 5 Gy for 60Co gamma rays. More importantly, the present study using 7Li and 12C ions clearly shows that response of the FBX dosimeter is linear for high LET radiations at low as well as high doses.

  15. Columbia Accident Probe Widens

    NASA Technical Reports Server (NTRS)

    Covault, Craig

    2003-01-01

    The Columbia Accident Investigation Board has identified about a dozen shuttle program safety concerns it will address in its final report, in addition to foam shedding from the Lockheed Martin external tank-believed by many board members to be the direct cause for the loss of Columbia and her crew. As new evidence narrows the location of Columbia's left-wing breach to a lower corner of reinforced carbon-carbon (RCC) Panel 8 and its adjoining T-seal, the board is broadening its penetration of other shuttle safety issues. As the board works in Houston, United Space Alliance technicians here at Kennedy last week sent the first six of 22 RCC panels from the orbiter Atlantis left wing to Vought Aircraft Industries Inc. in Dallas for extensive testing to assess their integrity. The move is a key step toward both returning the shuttle to flight with Atlantis and obtaining more data on RCC panels subjected to fewer flights, and less exposure to the weather, than the older panels used on Columbia.

  16. Intercomparison of stratospheric gravity wave observations with AIRS and IASI

    NASA Astrophysics Data System (ADS)

    Hoffmann, Lars; Alexander, M. Joan; Clerbaux, Cathy; Grimsdell, Alison W.; Meyer, Catrin I.; Rößler, Thomas; Tournier, Bernard

    2015-04-01

    Gravity waves are an important driver for the atmospheric circulation and have substantial impact on weather and climate. Satellite instruments offer excellent opportunities to study gravity waves on a global scale. This study focuses on observations from the Atmospheric Infrared Sounder (AIRS) onboard the National Aeronautics and Space Administration's Aqua satellite and the Infrared Atmospheric Sounding Interferometer (IASI) onboard the European MetOp satellites. The main aim of this study is an intercomparison of stratospheric gravity wave observations of both instruments. In particular, we analyzed AIRS and IASI 4.3 μm brightness temperature measurements, which directly relate to stratospheric temperature. Three case studies showed that AIRS and IASI provide a clear and consistent picture of the temporal development of individual gravity wave events. Statistical comparisons based on a five-year period of measurements (2008 - 2012) showed similar spatial and temporal patterns of gravity wave activity. However, the statistical comparisons also revealed systematic differences of variances between AIRS and IASI that we attribute to the different spatial measurement characteristics of both instruments. We also found differences between day- and nighttime data that are partly due to the local time variations of the gravity wave sources. While AIRS has been used successfully in many previous gravity wave studies, IASI data are applied here for the first time for that purpose. Our study shows that gravity wave observations from different hyperspectral infrared sounders such as AIRS and IASI can be directly related to each other, if instrument-specific characteristics such as different noise levels and spatial resolution and sampling are carefully considered. The ability to combine observations from different satellites provides an opportunity to create a long-term record, which is an exciting prospect for future climatological studies of stratospheric gravity wave

  17. Overview of the Coupled Model Intercomparison Project (CMIP)

    SciTech Connect

    Meehl, G A; Covey, C; McAvaney, B; Latif, M; Stouffer, R J

    2004-08-05

    The Coupled Model Intercomparison Project (CMIP) is designed to allow study and intercomparison of multi-model simulations of present-day and future climate. The latter are represented by idealized forcing of compounded 1% per year CO2 increase to the time of CO2 doubling near year 70 in simulations with global coupled models that contain, typically, components representing atmosphere, ocean, sea ice and land surface. Results from CMIP diagnostic subprojects were presented at the Second CMIP Workshop held at the Max Planck Institute for Meteorology in Hamburg, Germany, in September, 2003. Significant progress in diagnosing and understanding results from global coupled models has been made since the First CMIP Workshop in Melbourne, Australia in 1998. For example, the issue of flux adjustment is slowly fading as more and more models obtain stable multi-century surface climates without them. El Nino variability, usually about half the observed amplitude in the previous generation of coupled models, is now more accurately simulated in the present generation of global coupled models, though there are still biases in simulating the patterns of maximum variability. Typical resolutions of atmospheric component models contained in coupled models is now usually around 2.5 degrees latitude-longitude, with the ocean components often having about twice the atmospheric model resolution, with even higher resolution in the equatorial tropics. Some new-generation coupled models have atmospheric model resolutions of around 1.5 degrees latitude-longitude. Modeling groups now routinely run the CMIP control and 1% CO2 simulations in addition to 20th and 21st century climate simulations with a variety of forcings (e.g. volcanoes, solar variability, anthropogenic sulfate aerosols, ozone, and greenhouse gases (GHGs), with the anthropogenic forcings for future climate as well). However, persistent systematic errors noted in previous generations of global coupled models still are present

  18. Intercomparison of mid latitude storm diagnostics (IMILAST) - project update

    NASA Astrophysics Data System (ADS)

    Neu, Urs

    2015-04-01

    The analysis of the occurrence of mid-latitude storms is of great socio-economical interest due to their vast and destructive impacts. However, a unique definition of cyclones is missing, and therefore the definition of what a cyclone is as well as quantifying its strength contains subjective choices. Existing automatic cyclone identification and tracking algorithms are based on different definitions and use diverse characteristics. These methods generally differ in the following aspects: data transformation (e.g., grid transformation, smoothing, etc.), metrics used for cyclone identification (e.g. sea level pressure or vorticity), cyclone identification procedures, different tracking methods (e.g. near neighborhood search), and elimination criteria (e.g., requiring a certain pressure minimum or minimum life time). The different choices made in these algorithms can lead to substantial differences in cyclone climatologies, temporal trends of the frequency, strength, or other characteristics of cyclones. The project IMILAST systematically compares different cyclone detection and tracking methods (currently 15 different algorithms), with the aim to comprehensively assess systematic uncertainties in mid-latitudinal storm identification and tracking. IMILAST uses the ERA-interim reanalysis data set as a common data basis in all studies. The first two intercomparison experiments focused on differences between the methods with respect to number, track density, life cycle characteristics, and trend patterns on the one hand and potential differences of the long-term climate change signal of cyclonic activity between the methods on the other hand. For current analysis activities, the intercomparison period is extended to a 30 year period from 1979 to 2009 and focuses on more specific aspects, such as parameter sensitivities, the comparison of automated to manual tracking sets, regional analysis (regional trends, Arctic and Antarctic cyclones, cyclones in the Mediterranean

  19. Aircraft accidents : method of analysis

    NASA Technical Reports Server (NTRS)

    1929-01-01

    This report on a method of analysis of aircraft accidents has been prepared by a special committee on the nomenclature, subdivision, and classification of aircraft accidents organized by the National Advisory Committee for Aeronautics in response to a request dated February 18, 1928, from the Air Coordination Committee consisting of the Assistant Secretaries for Aeronautics in the Departments of War, Navy, and Commerce. The work was undertaken in recognition of the difficulty of drawing correct conclusions from efforts to analyze and compare reports of aircraft accidents prepared by different organizations using different classifications and definitions. The air coordination committee's request was made "in order that practices used may henceforth conform to a standard and be universally comparable." the purpose of the special committee therefore was to prepare a basis for the classification and comparison of aircraft accidents, both civil and military. (author)

  20. 49 CFR 801.32 - Accident reports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Accident reports. 801.32 Section 801.32... PUBLIC AVAILABILITY OF INFORMATION Accident Investigation Records § 801.32 Accident reports. (a) The NTSB....S. civil transportation accidents, in accordance with 49 U.S.C. 1131(e). (b) These reports may...

  1. 29 CFR 1960.29 - Accident investigation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Accident investigation. 1960.29 Section 1960.29 Labor... MATTERS Inspection and Abatement § 1960.29 Accident investigation. (a) While all accidents should be investigated, including accidents involving property damage only, the extent of such investigation shall...

  2. 49 CFR 195.54 - Accident reports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Accident reports. 195.54 Section 195.54... PIPELINE Annual, Accident, and Safety-Related Condition Reporting § 195.54 Accident reports. (a) Each operator that experiences an accident that is required to be reported under § 195.50 must, as soon...

  3. 49 CFR 230.22 - Accident reports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Accident reports. 230.22 Section 230.22... Requirements § 230.22 Accident reports. In the case of an accident due to failure, from any cause, of a steam... persons, the railroad on whose line the accident occurred shall immediately make a telephone report of...

  4. 49 CFR 845.40 - Accident report.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Accident report. 845.40 Section 845.40... RULES OF PRACTICE IN TRANSPORTATION; ACCIDENT/INCIDENT HEARINGS AND REPORTS Board Reports § 845.40 Accident report. (a) The Board will issue a detailed narrative accident report in connection with...

  5. 29 CFR 1960.29 - Accident investigation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Accident investigation. 1960.29 Section 1960.29 Labor... MATTERS Inspection and Abatement § 1960.29 Accident investigation. (a) While all accidents should be investigated, including accidents involving property damage only, the extent of such investigation shall...

  6. 49 CFR 230.22 - Accident reports.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Accident reports. 230.22 Section 230.22... Requirements § 230.22 Accident reports. In the case of an accident due to failure, from any cause, of a steam... persons, the railroad on whose line the accident occurred shall immediately make a telephone report of...

  7. 49 CFR 195.54 - Accident reports.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Accident reports. 195.54 Section 195.54... PIPELINE Annual, Accident, and Safety-Related Condition Reporting § 195.54 Accident reports. (a) Each operator that experiences an accident that is required to be reported under § 195.50 shall as soon...

  8. 49 CFR 845.40 - Accident report.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Accident report. 845.40 Section 845.40... RULES OF PRACTICE IN TRANSPORTATION; ACCIDENT/INCIDENT HEARINGS AND REPORTS Board Reports § 845.40 Accident report. (a) The Board will issue a detailed narrative accident report in connection with...

  9. 49 CFR 801.32 - Accident reports.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Accident reports. 801.32 Section 801.32... PUBLIC AVAILABILITY OF INFORMATION Accident Investigation Records § 801.32 Accident reports. (a) The NTSB....S. civil transportation accidents, in accordance with 49 U.S.C. 1131(e). (b) These reports may...

  10. Neutron dosimetry at commercial nuclear plants. Final report of Subtask B: dosimeter response

    SciTech Connect

    Cummings, F.M.; Endres, G.W.R.; Brackenbush, L.W.

    1983-03-01

    As part of a larger program to evaluate personnel neutron dosimetry at commercial nuclear power plants, this study was designed to characterize neutron dosimeter responses inside the containment structure of commercial nuclear plants. In order to characterize those responses, dosimeters were irradiated inside containment at 2 pressurized water reactors and at pipe penetrations outside the biological shield at two boiling water reactors. The reactors were operating at full power during the irradiations. Measurements were also performed with electronic instruments, the tissue equivalent proportional counter (TEPC), and portable remmeters, SNOOPY, RASCAL and PNR-4.

  11. Novel Multicompartment 3-Dimensional Radiochromic Radiation Dosimeters for Nanoparticle-Enhanced Radiation Therapy Dosimetry

    SciTech Connect

    Alqathami, Mamdooh; Blencowe, Anton; Yeo, Un Jin; Doran, Simon J.; Qiao, Greg; Geso, Moshi

    2012-11-15

    Purpose: Gold nanoparticles (AuNps), because of their high atomic number (Z), have been demonstrated to absorb low-energy X-rays preferentially, compared with tissue, and may be used to achieve localized radiation dose enhancement in tumors. The purpose of this study is to introduce the first example of a novel multicompartment radiochromic radiation dosimeter and to demonstrate its applicability for 3-dimensional (3D) dosimetry of nanoparticle-enhanced radiation therapy. Methods and Materials: A novel multicompartment phantom radiochromic dosimeter was developed. It was designed and formulated to mimic a tumor loaded with AuNps (50 nm in diameter) at a concentration of 0.5 mM, surrounded by normal tissues. The novel dosimeter is referred to as the Sensitivity Modulated Advanced Radiation Therapy (SMART) dosimeter. The dosimeters were irradiated with 100-kV and 6-MV X-ray energies. Dose enhancement produced from the interaction of X-rays with AuNps was calculated using spectrophotometric and cone-beam optical computed tomography scanning by quantitatively comparing the change in optical density and 3D datasets of the dosimetric measurements between the tissue-equivalent (TE) and TE/AuNps compartments. The interbatch and intrabatch variability and the postresponse stability of the dosimeters with AuNps were also assessed. Results: Radiation dose enhancement factors of 1.77 and 1.11 were obtained using 100-kV and 6-MV X-ray energies, respectively. The results of this study are in good agreement with previous observations; however, for the first time we provide direct experimental confirmation and 3D visualization of the radiosensitization effect of AuNps. The dosimeters with AuNps showed small (<3.5%) interbatch variability and negligible (<0.5%) intrabatch variability. Conclusions: The SMART dosimeter yields experimental insights concerning the spatial distributions and elevated dose in nanoparticle-enhanced radiation therapy, which cannot be performed using any of

  12. On the response of electronic personal dosimeters in constant potential and pulsed x- ray beams

    NASA Astrophysics Data System (ADS)

    Guimarães, M. C.; Silva, C. R. E.; Oliveira, P. M. C.; da Silva, T. A.

    2016-07-01

    Electronic personal dosimeters (EPDs) based on solid state detectors have widely been used but some deficiencies in their response in pulsed radiation beams have been reported. Nowadays, there is not an international standard for pulsed x-ray beams for calibration or type testing of dosimeters. Irradiation conditions for testing the response of EPDs in both the constant potential and pulsed x-ray beams were established in CDTN. Three different types of EPDs were tested in different conditions in similar ISO and IEC x-ray qualities. Results stressed the need of performing additional checks before using EPDs in constant potential or pulsed x-rays.

  13. Experimental determination of the influence of oxygen on the PRESAGE® dosimeter

    NASA Astrophysics Data System (ADS)

    Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2016-01-01

    It is generally accepted that the PRESAGE® radiochromic dosimeter is not sensitive to oxygen, however, this claim has not been supported or verified experimentally. Therefore, the aim of this study was to experimentally determine the potential influence of oxygen on dose sensitivity of the PRESAGE® dosimeter and its reporting system. Batches of PRESAGE® and its radical initiator-leuco dye reporting system were prepared in aerobic and anaerobic conditions. The anaerobic batches were deoxygenated by bubbling nitrogen through the dosimeter precursors or reporting system for 10 min. The dosimeters and reporting systems were prepared in spectrophotometric cuvettes and glass vials, respectively, and were irradiated with 6 MV photons to various radiation doses. Changes in optical density of the dosimeters and reporting system before and after irradiation were measured using a spectrophotometer. The overall results show that oxygen has some influence on the dosimetric characteristics of PRESAGE®, although the radical initiator does appear to oxidize the leucomalachite green even in the presence of oxygen. Deoxygenation of the reporting system leads to an increase in sensitivity to radiation dose by ~30% when compared to the non-deoxygenated system. A minor increase in sensitivity (~5%) was also achieved by deoxygenating the PRESAGE® precursor prior to casting. In addition, dissolved oxygen measurements revealed low levels of dissolved oxygen (0.40  ±  0.04 mg l-1) in the polyurethane precursor used to fabricate the PRESAGE® dosimeters, as compared to water (8.60  ±  0.03 mg l-1) and the reporting system alone (1.30  ±  0.10 mg l-1). The results suggest that the presence of oxygen does not inhibit the radiochromic properties of the PRESAGE® system. However, deoxygenation of the dosimeter precursors prior to casting improves the dosimeters dose sensitivity by ~5%, which might be particularly useful for measuring low radiation doses

  14. Initial characterization of a gel patch dosimeter for in vivo dosimetry

    NASA Astrophysics Data System (ADS)

    Matrosic, C.; Culberson, W.; Rosen, B.; Madsen, E.; Frank, G.; Bednarz, B.

    2016-05-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose–responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose–response of all three batches of gel was found to be linear within the range of 2–20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in

  15. Initial characterization of a gel patch dosimeter for in vivo dosimetry.

    PubMed

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2016-05-21

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose-response of all three batches of gel was found to be linear within the range of 2-20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  16. Simulation and test of a new albedo personal dosimeter for neutrons

    NASA Astrophysics Data System (ADS)

    Manfredotti, C.; Zanini, A.; Rollet, S.; Arman, G.

    1989-12-01

    A new personal dosimeter for neutrons, using three TLD 600s and one TLD 700 in a cadmium housing and detecting both incoming and albedo neutrons, has been designed, developed, tested and simulated by the code MORSE. Its response in the energy region between 10 -8 and 10 MeV is more similar to ICRP fluence-dose equivalent calibration factor behaviour with respect to previous albedo dosimeters, and particularly fast neutron tissue dose equivalents are less underestimated. Present data confirm that both accuracy and precision fulfil the International Commissions requests (NCR, NCRP, ANSI). Theory, simulation and experimental results obtained with a laboratory prototype are presented and discussed.

  17. A Bremsstrahlung Spectrometer using k-edge and Differential Filters with Image plate dosimeters

    SciTech Connect

    Chen, C; Mackinnon, A; Beg, F; Chen, H; Key, M; King, J A; Link, A; MacPhee, A; Patel, P; Porkolab, M; Stephens, R; VanWoerkom, L; Akli, K; Freeman, R

    2008-05-02

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with Image Plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code Integrated Tiger Series 3.0 and the dosimeters calibrated with radioactive sources. Electron distributions with slope temperatures in the MeV range are inferred from the Bremsstrahlung spectra.

  18. A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

    SciTech Connect

    Chen, C. D.; Porkolab, M.; King, J. A.; Beg, F. N.; Key, M. H.; Chen, H.; Mackinnon, A. J.; MacPhee, A. G.; Patel, P. K.; Akli, K. U.; Stephens, R. B.; Freeman, R. R.; Link, A.; Van Woerkom, L. D.

    2008-10-15

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

  19. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    PubMed

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-01-01

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in

  20. Initial Characterization of a Gel Patch Dosimeter for In Vivo Dosimetry

    PubMed Central

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2016-01-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6%T normoxic polyacrylamide gel, was injected into 1-cm thick acrylic molds to create 1-cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose response of all three batches of gel was found to be linear within the range of 2–20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  1. An in-house developed resettable MOSFET dosimeter for radiotherapy.

    PubMed

    Verellen, Dirk; Van Vaerenbergh, Sven; Tournel, Koen; Heuninckx, Karina; Joris, Laurent; Duchateau, Michael; Linthout, Nadine; Gevaert, Thierry; Reynders, Truus; Van de Vondel, Iwein; Coppens, Luc; Depuydt, Tom; De Ridder, Mark; Storme, Guy

    2010-02-21

    The purpose of this note is to report the feasibility and clinical validation of an in-house developed MOSFET dosimetry system and describe an integrated non-destructive reset procedure. Off-the-shelf MOSFETs are connected to a common PC using an 18 bit/analogue-input and 16 bit/output data acquisition card. A reading algorithm was developed defining the zero-temperature-coefficient point (ZTC) to determine the threshold voltage. A wireless interface was established for ease of use. The reset procedure consists of an internal circuit generating a local heating induced by an electrical current. Sensitivity has been investigated as a function of bias voltage (0-9 V) to the gate. Dosimetric properties have been evaluated for 6 MV and 15 MV clinical photon beams and in vivo benchmarking was performed against thermoluminescence dosimeters (TLD) for conventional treatments (two groups of ten patients for each energy) and total body irradiation (TBI). MOSFETS were pre-irradiated with 20 Gy. Sensitivity of 0.08 mV cGy(-1) can be obtained for 200 cGy irradiations at 5 V bias voltage. Ten consecutive measurements at 200 cGy yield a SD of 2.08 cGy (1.05%). Increasing the dose in steps from 5 cGy to 1000 cGy yields a 1.00 Pearson correlation coefficient and agreement within 2.0%. Dose rate dependence (160-800 cGy min(-1)) was within 2.5%, temperature dependence within 2.0% (25-37 degrees C). A strong angular dependence has been observed for gantry incidences exceeding +/-30 degrees C. Dose response is stable up to 50 Gy (saturation occurs at approximately 90 Gy), which is used as threshold dose before resetting the MOSFET. An average measured-over-calculated dose ratio within 1.05 (SD: 0.04) has been obtained in vivo. TBI midplane-dose assessed by entrance and exit dose measurements agreed within 1.9% with ionization chamber in phantom, and within 1.0% with TLD in vivo. An in-house developed resettable MOSFET-based dosimetry system is proposed. The system has been validated

  2. Spine Immobilizer for Accident Victims

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C.; Lampson, K.

    1983-01-01

    Proposed conformal bladder filled with tiny spheres called "microballoons," enables spine of accident victim to be rapidly immobilized and restrained and permit victim to be safely removed from accident scene in extremely short time after help arrives. Microballoons expand to form rigid mass when pressure within bladder is less than ambient. Bladder strapped to victim is also strapped to rescue chair. Void between bladder and chair is filled with cloth wedges.

  3. A gelatin-free model system for the study of the basic radiation-induced polymerization in PAG dosimeters

    NASA Astrophysics Data System (ADS)

    Babic, S.; Park, Y. S.; Schreiner, L. J.

    2004-01-01

    In this presentation we show results of investigations on gelatin-free dosimeters containing equal amounts of acrylamide and N,N'-methylene-bisacrylamide (named Aqueous Polyacrylamide, APA, dosimeters). The dosimeters were prepared with three different total monomer concentrations (2, 6, and 8% by weight). Nuclear magnetic resonance (NMR) spin-spin and spin-lattice proton relaxation measurements at 20 MHz, and gravimetric analyses performed on all three dosimeters, show a continuous degree of polymerization over the range of dose 0.5 - 25 Gy. The developed NMR model explains the relationship observed between the relaxation data and the amount of cross-linked polymer formed at each dose. This model may be extended with gelatin relaxation data to provide a fundamental understanding of radiation-induced polymerization in the conventional PAG dosimeters.

  4. Enhancement in dose sensitivity of polymer gel dosimeters composed of radiation-crosslinked gel matrix and less toxic monomers

    NASA Astrophysics Data System (ADS)

    Hiroki, A.; Yamashita, S.; Taguchi, M.

    2015-01-01

    Polymer gel dosimeters based on radiation-crosslinked hydroxypropyl cellulose gel were prepared, which comprised 2-hydroxyethyl methacrylate (HEMA) and polyethylene glycol #400 dimethacrylate (9G) as less toxic monomers and tetrakis (hydroxymethyl) phosphonium chloride (THPC) as an antioxidant. The dosimeters exposed to 60Co γ-rays became cloudy at only 1 Gy. The irradiated dosimeters were optically analyzed by using a UV- vis spectrophotometer to evaluate dose response. Absorbance of the dosimeters linearly increased in the dose range from 0 to 10 Gy, in which dose sensitivity increased with increasing 9G concentration. The dose sensitivity of the dosimeters with 2 wt% HEMA and 3 wt% 9G was also enhanced by increment in THPC.

  5. Invited Article: Radon and thoron intercomparison experiments for integrated monitors at NIRS, Japan

    SciTech Connect

    Janik, M. Ishikawa, T.; Omori, Y.; Kavasi, N.

    2014-02-15

    Inhalation of radon ({sup 222}Rn) and its short-lived decay products and of products of the thoron ({sup 220}Rn) series accounts for more than half of the effective dose from natural radiation sources. At this time, many countries have begun large-scale radon and thoron surveys and many different measurement methods and instruments are used in these studies. Consequently, it is necessary to improve and standardize technical methods of measurements and to verify quality assurance by intercomparisons between laboratories. Four international intercomparisons for passive integrating radon and thoron monitors were conducted at the NIRS (National Institute of Radiological Sciences, Japan). Radon exercises were carried out in the 24.4 m{sup 3} inner volume walk-in radon chamber that has systems to control radon concentration, temperature, and humidity. Moreover, the NIRS thoron chamber with a 150 dm{sup 3} inner volume was utilized to provide three thoron intercomparisons. At present, the NIRS is the only laboratory world-wide that has carried out periodic thoron intercomparison of passive monitors. Fifty laboratories from 26 countries participated in the radon intercomparison, using six types of detectors (charcoal, CR-39, LR 115, polycarbonate film, electret plate, and silicon photodiode). Eighteen laboratories from 12 countries participated in the thoron intercomparisons, using two etch-track types (CR-39 and polycarbonate) detectors. The tests were made under one to three different exposures to radon and thoron. The data presented in this paper indicated that the performance quality of laboratories for radon measurement has been gradually increasing. Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods. The present paper provides a summary of all radon and thoron international intercomparisons done at NIRS from 2007 to date and it describes the

  6. Nuclear fuel cycle facility accident analysis handbook

    SciTech Connect

    Ayer, J E; Clark, A T; Loysen, P; Ballinger, M Y; Mishima, J; Owczarski, P C; Gregory, W S; Nichols, B D

    1988-05-01

    The Accident Analysis Handbook (AAH) covers four generic facilities: fuel manufacturing, fuel reprocessing, waste storage/solidification, and spent fuel storage; and six accident types: fire, explosion, tornado, criticality, spill, and equipment failure. These are the accident types considered to make major contributions to the radiological risk from accidents in nuclear fuel cycle facility operations. The AAH will enable the user to calculate source term releases from accident scenarios manually or by computer. A major feature of the AAH is development of accident sample problems to provide input to source term analysis methods and transport computer codes. Sample problems and illustrative examples for different accident types are included in the AAH.

  7. The Program for Climate Model Diagnosis and Intercomparison Diagnostic System: Implementing a New Strategy Beyond the Atmospheric Model Intercomparison Project (AMIP)

    SciTech Connect

    Potter, G.L.

    1999-10-18

    The Program for Climate Model Diagnosis and Intercomparison (PCMDI) was established in 1989 at the Lawrence Livermore National Laboratory (LLNL) with the principal mission to develop improved methods and tools for the diagnosis, validation and intercomparison of global climate models. The goal of the process is to eventually improve simulation of the regional climate effects of increasing greenhouse gases. In addition to comparing models, PCMDI continues to develop a modeling infrastructure by creating diagnostics that will be shared throughout the research community. PCMDI's early model intercomparison strategy was to solicit a few models that could be run for a specified period with prescribed sea-surface temperatures after being imported and adapted to the LLNL unclassified computer systems. Because of the enormous time required to prepare each model, the experiment was reversed and the modeling groups were asked to perform the controlled simulations themselves. In order to reach out to the entire atmospheric modeling community, the Working Group for Numerical Experimentation (WGNE) became the parent organization and the project was named the Atmospheric Model Intercomparison Project (AMIP). Eventually, more than thirty atmospheric modeling groups joined the effort to compare their model output (Gates et al. 1999). The general results showed that the models vary widely for some variables and are tightly clustered for other variables. Fig. 1 characterizes the wide array of results obtained in AMIP and underscores the need to better understand differences among models and between models and observations. As a result of AMIP, model development and improvement strategy has incurred a permanent change. Modeling groups routinely perform AMIP-like simulations as they improve their models and create new versions containing substantial modifications to parameterizations. Other model intercomparison projects (MIPs) have since sprung up, most notably, the Coupled Model

  8. Severe accident analysis using dynamic accident progression event trees

    NASA Astrophysics Data System (ADS)

    Hakobyan, Aram P.

    In present, the development and analysis of Accident Progression Event Trees (APETs) are performed in a manner that is computationally time consuming, difficult to reproduce and also can be phenomenologically inconsistent. One of the principal deficiencies lies in the static nature of conventional APETs. In the conventional event tree techniques, the sequence of events is pre-determined in a fixed order based on the expert judgments. The main objective of this PhD dissertation was to develop a software tool (ADAPT) for automated APET generation using the concept of dynamic event trees. As implied by the name, in dynamic event trees the order and timing of events are determined by the progression of the accident. The tool determines the branching times from a severe accident analysis code based on user specified criteria for branching. It assigns user specified probabilities to every branch, tracks the total branch probability, and truncates branches based on the given pruning/truncation rules to avoid an unmanageable number of scenarios. The function of a dynamic APET developed includes prediction of the conditions, timing, and location of containment failure or bypass leading to the release of radioactive material, and calculation of probabilities of those failures. Thus, scenarios that can potentially lead to early containment failure or bypass, such as through accident induced failure of steam generator tubes, are of particular interest. Also, the work is focused on treatment of uncertainties in severe accident phenomena such as creep rupture of major RCS components, hydrogen burn, containment failure, timing of power recovery, etc. Although the ADAPT methodology (Analysis of Dynamic Accident Progression Trees) could be applied to any severe accident analysis code, in this dissertation the approach is demonstrated by applying it to the MELCOR code [1]. A case study is presented involving station blackout with the loss of auxiliary feedwater system for a

  9. An Intercomparison of 2-D Models Within a Common Framework

    NASA Technical Reports Server (NTRS)

    Weisenstein, Debra K.; Ko, Malcolm K. W.; Scott, Courtney J.; Jackman, Charles H.; Fleming, Eric L.; Considine, David B.; Kinnison, Douglas E.; Connell, Peter S.; Rotman, Douglas A.; Bhartia, P. K. (Technical Monitor)

    2002-01-01

    A model intercomparison among the Atmospheric and Environmental Research (AER) 2-D model, the Goddard Space Flight Center (GSFC) 2-D model, and the Lawrence Livermore National Laboratory 2-D model allows us to separate differences due to model transport from those due to the model's chemical formulation. This is accomplished by constructing two hybrid models incorporating the transport parameters of the GSFC and LLNL models within the AER model framework. By comparing the results from the native models (AER and e.g. GSFC) with those from the hybrid model (e.g. AER chemistry with GSFC transport), differences due to chemistry and transport can be identified. For the analysis, we examined an inert tracer whose emission pattern is based on emission from a High Speed Civil Transport (HSCT) fleet; distributions of trace species in the 2015 atmosphere; and the response of stratospheric ozone to an HSCT fleet. Differences in NO(y) in the upper stratosphere are found between models with identical transport, implying different model representations of atmospheric chemical processes. The response of O3 concentration to HSCT aircraft emissions differs in the models from both transport-dominated differences in the HSCT-induced perturbations of H2O and NO(y) as well as from differences in the model represent at ions of O3 chemical processes. The model formulations of cold polar processes are found to be the most significant factor in creating large differences in the calculated ozone perturbations

  10. Intercomparison of selected fixed-area areal reduction factor methods

    NASA Astrophysics Data System (ADS)

    Pavlovic, Sandra; Perica, Sanja; St Laurent, Michael; Mejía, Alfonso

    2016-06-01

    The areal reduction factor (ARF) is a concept used in many hydrologic designs to transform a point precipitation frequency estimate of a given duration and frequency to a corresponding areal estimate. Various methods have been proposed in the literature to calculate ARFs. Proposed ARFs could vary significantly, and it is unclear if discrepancies are primarily due to differences in methodologies, the dissimilar datasets used to calculate ARFs, or if they originate from regional uniqueness. Our goal in this study is to analyze differences among ARFs derived from different types of fixed-area ARF methods, which are suitable for use with precipitation frequency estimates. For this intercomparison, all the ARFs were computed using the same, high-quality rainfall-radar merged dataset for a common geographic region. The selected ARFs methods represent four commonly used approaches: empirical methods, methods that are based on the spatial correlation structure of rainfall, methods that rely on the scaling properties of rainfall in space and time, and methods that utilize extreme value theory. The state of Oklahoma was selected as the study area, as it has a good quality radar data and a dense network of rain gauges. Results indicate significant uncertainties in the ARF estimates, regardless of the method used. Even when calculated from the same dataset and for the same geographic area, the ARF estimates from the selected methods differ. The differences are more pronounced for the shorter durations and larger areas. Results also indicate some ARF dependence on the average recurrence intervals.

  11. Three models intercomparison for Quantitative Precipitation Forecast over Calabria

    NASA Astrophysics Data System (ADS)

    Federico, S.; Avolio, E.; Bellecci, C.; Colacino, M.; Lavagnini, A.; Accadia, C.; Mariani, S.; Casaioli, M.

    2004-11-01

    In the framework of the National Project “Sviluppo di distretti industriali per le Osservazioni della Terra” (Development of Industrial Districts for Earth Observations) funded by MIUR (Ministero dell'Università e della Ricerca Scientifica --Italian Ministry of the University and Scientific Research) two operational mesoscale models were set-up for Calabria, the southernmost tip of the Italian peninsula. Models are RAMS (Regional Atmospheric Modeling System) and MM5 (Mesoscale Modeling 5) that are run every day at Crati scrl to produce weather forecast over Calabria (http://www.crati.it). This paper reports model intercomparison for Quantitative Precipitation Forecast evaluated for a 20 month period from 1th October 2000 to 31th May 2002. In addition to RAMS and MM5 outputs, QBOLAM rainfall fields are available for the period selected and included in the comparison. This model runs operationally at “Agenzia per la Protezione dell'Ambiente e per i Servizi Tecnici”. Forecasts are verified comparing models outputs with raingauge data recorded by the regional meteorological network, which has 75 raingauges. Large-scale forcing is the same for all models considered and differences are due to physical/numerical parameterizations and horizontal resolutions. QPFs show differences between models. Largest differences are for BIA compared to the other considered scores. Performances decrease with increasing forecast time for RAMS and MM5, whilst QBOLAM scores better for second day forecast.

  12. Intercomparison of radiation protection instrumentation in a pulsed neutron field

    NASA Astrophysics Data System (ADS)

    Caresana, M.; Denker, A.; Esposito, A.; Ferrarini, M.; Golnik, N.; Hohmann, E.; Leuschner, A.; Luszik-Bhadra, M.; Manessi, G.; Mayer, S.; Ott, K.; Röhrich, J.; Silari, M.; Trompier, F.; Volnhals, M.; Wielunski, M.

    2014-02-01

    In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of the exercise was to evaluate the performances of various neutron instruments, including commercially available rem-counters, personal dosemeters and instrument prototypes. The measurements took place at the cyclotron of the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH. The cyclotron is routinely used for proton therapy of ocular tumours, but an experimental area is also available. For the therapy the machine accelerates protons to 68 MeV. The interaction of the proton beam with a thick tungsten target produces a neutron field with energy up to about 60 MeV. One interesting feature of the cyclotron is that the beam can be delivered in bursts, with the possibility to modify in a simple and flexible way the burst length and the ion current. Through this possibility one can obtain radiation bursts of variable duration and intensity. All instruments were placed in a reference position and irradiated with neutrons delivered in bursts of different intensity. The analysis of the instrument response as a function of the burst charge (the total electric charge of the protons in the burst shot onto the tungsten target) permitted to assess for each device the dose underestimation due to the time structure of the radiation field. The personal neutron dosemeters were exposed on a standard PMMA slab phantom and the response linearity was evaluated.

  13. Peroxy radical partitioning during the AMMA radical intercomparison exercise

    NASA Astrophysics Data System (ADS)

    Andrés-Hernández, M. D.; Stone, D.; Brookes, D. M.; Commane, R.; Reeves, C. E.; Huntrieser, H.; Heard, D. E.; Monks, P. S.; Burrows, J. P.; Schlager, H.; Kartal, D.; Evans, M. J.; Floquet, C. F. A.; Ingham, T.; Methven, J.; Parker, A. E.

    2010-11-01

    Peroxy radicals were measured onboard two scientific aircrafts during the AMMA (African Monsoon Multidisciplinary Analysis) campaign in summer 2006. This paper reports results from the flight on 16 August 2006 during which measurements of HO2 by laser induced fluorescence spectroscopy at low pressure (LIF-FAGE) and total peroxy radicals (RO2* = HO2+ΣRO2, R = organic chain) by two similar instruments based on the peroxy radical chemical amplification (PeRCA) technique were subject of a blind intercomparison. The German DLR-Falcon and the British FAAM-BAe-146 flew wing tip to wing tip for about 30 min making concurrent measurements on 2 horizontal level runs at 697 and 485 hPa over the same geographical area in Burkina Faso. A full set of supporting measurements comprising photolysis frequencies, and relevant trace gases like CO, NO, NO2, NOy, O3 and a wider range of VOCs were collected simultaneously. Results are discussed on the basis of the characteristics and limitations of the different instruments used. Generally, no data bias are identified and the RO2* data available agree quite reasonably within the instrumental errors. The [RO2*]/[HO2] ratios, which vary between 1:1 and 3:1, as well as the peroxy radical variability, concur with variations in photolysis rates and in other potential radical precursors. Model results provide additional information about dominant radical formation and loss processes.

  14. Peroxy radical partitioning during the AMMA radical intercomparison exercise

    NASA Astrophysics Data System (ADS)

    Andrés-Hernández, M. D.; Stone, D.; Brookes, D. M.; Commane, R.; Reeves, C. E.; Huntrieser, H.; Heard, D. E.; Monks, P. S.; Burrows, J. P.; Schlager, H.; Kartal, D.; Evans, M. J.; Floquet, C. F. A.; Ingham, T.; Methven, J.; Parker, A. E.

    2010-04-01

    Peroxy radicals were measured onboard two scientific aircrafts during the AMMA (African Monsoon Multidisciplinary Analysis) campaign in summer 2006. This paper reports results from the flight on 16 August 2006 during which measurements of HO2 by laser induced fluorescence spectroscopy at low pressure (LIF-FAGE) and total peroxy radicals (RO2*=HO2+ΣRO2, R= organic chain) by two similar instruments based on the peroxy radical chemical amplification (PerCA) technique were subject of a blind intercomparison. The German DLR-Falcon and the British FAAM-BAe-146 flew wing tip to wing tip for about 30 min making concurrent measurements on 2 horizontal level runs at 697 and 485 hPa over the same geographical area in Burkina Faso. A full set of supporting measurements comprising photolysis frequencies, and relevant trace gases like CO, NO, NO2, NOy, O3 and a wider range of VOCs were collected simultaneously. Results are discussed on the basis of the characteristics and limitations of the different instruments used. Generally, no data bias are identified and the RO2* data available agree quite reasonably within the instrumental errors. The [RO2*]/[HO2] ratios, which vary between 1:1 and 3:1, as well as the peroxy radical variability, concur with variations in photolysis rates and in other potential radical precursors. Model results provide additional information about dominant radical formation and loss processes.

  15. Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program.

    PubMed

    Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W

    2011-08-01

    The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h. PMID:21709505

  16. Interannual climate variability seen in the Pliocene Model Intercomparison Project

    NASA Astrophysics Data System (ADS)

    Brierley, C. M.

    2014-09-01

    Following proxy observations of weakened temperature gradients along the Equator in the early Pliocene, there has been much speculation about Pliocene climate variability. A major advance for our knowledge about the later Pliocene has been the coordination of modelling efforts through the Pliocene Model Intercomparison Project (PlioMIP). Here the changes in interannual modes of sea surface temperature variability will be presented across PlioMIP. Previously model ensembles have shown little consensus in the response of the El Niño-Southern Oscillation (ENSO) to imposed forcings - either for the past or future. The PlioMIP ensemble, however, shows surprising agreement with eight models simulating reduced variability and only one model indicating no change. The Pliocene's robustly weaker ENSO also saw a shift to lower frequencies. Model ensembles focussed at a wide variety of forcing scenarios have not yet shown this level of coherency. Nonetheless the PlioMIP ensemble does not show a robust response of either ENSO flavour or sea surface temperature variability in the Tropical Indian and North Pacific Oceans. Existing suggestions of ENSO properties linked to changes in zonal temperature gradient, seasonal cycle and the elevation of the Andes Mountains are investigated, yet prove insufficient to explain the coherent response. The reason for this surprisingly coherent signal warrants further investigation.

  17. Interannual climate variability seen in the Pliocene Model Intercomparison Project

    NASA Astrophysics Data System (ADS)

    Brierley, C. M.

    2015-03-01

    Following reconstructions suggesting weakened temperature gradients along the Equator in the early Pliocene, there has been much speculation about Pliocene climate variability. A major advance for our knowledge about the later Pliocene has been the coordination of modelling efforts through the Pliocene Model Intercomparison Project (PlioMIP). Here the changes in interannual modes of sea surface temperature variability will be presented across PlioMIP. Previously, model ensembles have shown little consensus in the response of the El Niño-Southern Oscillation (ENSO) to imposed forcings - either for the past or future. The PlioMIP ensemble, however, shows surprising agreement, with eight models simulating reduced variability and only one model indicating no change. The Pliocene's robustly weaker ENSO also saw a shift to lower frequencies. Model ensembles focussed on a wide variety of forcing scenarios have not yet shown this level of coherency. Nonetheless, the PlioMIP ensemble does not show a robust response of either ENSO flavour or sea surface temperature variability in the tropical Indian and North Pacific oceans. Existing suggestions linking ENSO properties to to changes in zonal temperature gradient, seasonal cycle and the elevation of the Andes Mountains are investigated, yet prove insufficient to explain the consistent response. The reason for this surprisingly coherent signal warrants further investigation.

  18. Climate Model Intercomparison at the Dynamics Level (Invited)

    NASA Astrophysics Data System (ADS)

    Tsonis, A.; Steinhaeuser, K.

    2013-12-01

    Until now, climate model intercomparison has focused primarily on annual and global averages of various quantities or on specific components, not on how well the general dynamics in the models compare to each other. In order to address how well models agree when it comes to dynamics they generate, we have adopted a new approach based on climate networks. We have considered 28 pre-industrial control runs as well as 70 20th-century forced runs from 23 climate models and have constructed networks for the 500 hPa, surface air temperature (SAT), sea level pressure (SLP), and precipitation fields for each run. Then we employed a widely used algorithm to derive the community structure in these networks. Communities separate 'nodes' in the network sharing similar dynamics. It has been shown that these communities, or sub-systems, in the climate system are associated with major climate modes and physics of the atmosphere. Once the community structure for all runs is derived, we use a pattern matching statistic to obtain a measure of how well any two models agree with each other. We find that, with possibly the exception of the 500 hPa field, the consistency for the SAT, SLP, and precipitation fields is questionable. More importantly, none of the models comes close to the community structure of the actual observations (reality). This is a significant finding especially for the temperature and precipitation fields, as these are the fields widely used to produce future projections in time and in space.

  19. A climate model intercomparison at the dynamics level

    NASA Astrophysics Data System (ADS)

    Tsonis, A.; Steinhaeuser, K.

    2012-12-01

    Up to now climate model intercomparison has focused on annual and global averages of various quantities or on specific components, not on how well the general dynamics in the models compare to each other. In order to address how well the models agree when it comes to dynamics they generate, we have adopted a new approach based on climate networks. We have considered 57 20th-century control runs from 17 climate models and have constructed networks for the 500 hPa, surface air temperature (SAT), and sea level pressure (SLP) fields for each run. Then we used two different algorithms to derive the community structure in these networks. Communities separate "nodes' in the network sharing similar dynamics. It has been shown that these communities, or sub-systems, in the climate system are associated with major climate modes and physics of the atmosphere 1-3. Once the community structure for all runs is derived we use a pattern matching statistic to obtain a measure of how well any two models agree with each other. We find that with possibly the exception of the 500 hPa filed, the consistency for the SLP and especially SAT fields is questionable. More importantly none of the models comes close to the community structure of the actual observations (reality). This is a significant finding especially for the temperature field, as this is the field predicted to produce temperature projections in time and in space.

  20. A climate model intercomparison at the dynamics level

    NASA Astrophysics Data System (ADS)

    Tsonis, Anastasios; Steinhaeuser, Karsten

    2013-04-01

    Until now, climate model intercomparison has focused primarily on annual and global averages of various quantities or on specific components, not on how well the general dynamics in the models compare to each other. In order to address how well models agree when it comes to dynamics they generate, we have adopted a new approach based on climate networks. We have considered 28 pre-industrial control runs as well as 70 20th-century forced runs from 23 climate models and have constructed networks for the 500 hPa, surface air temperature (SAT), sea level pressure (SLP), and precipitation fields for each run. Then we employed a widely used algorithm to derive the community structure in these networks. Communities separate "nodes" in the network sharing similar dynamics. It has been shown that these communities, or sub-systems, in the climate system are associated with major climate modes and physics of the atmosphere. Once the community structure for all runs is derived, we use a pattern matching statistic to obtain a measure of how well any two models agree with each other. We find that, with possibly the exception of the 500 hPa field, the consistency for the SAT, SLP, and precipitation fields is questionable. More importantly, none of the models comes close to the community structure of the actual observations (reality). This is a significant finding especially for the temperature and precipitation fields, as these are the fields widely used to produce future projections in time and in space.