Science.gov

Sample records for accomplish adequate sterilization

  1. Accomplishments '70.

    ERIC Educational Resources Information Center

    Stanford Univ., CA. Stanford Center for Research and Development in Teaching.

    This annual report examines the accomplishments during 1970 of three programs. The first program was to improve the organizational and administrative environment for teaching. Its subsidiary projects were 1) the organizational context of teaching; 2) professional socialization of the teacher; 3) attitudes of teachers toward their occupation; 4)…

  2. Effectiveness of dental office instrument sterilization procedures.

    PubMed

    Hastreiter, R J; Molinari, J A; Falken, M C; Roesch, M H; Gleason, M J; Merchant, V A

    1991-10-01

    To evaluate instrument sterilization procedures in Minnesota, biological indicators were used to monitor 406 sterilizers in 381 dental offices. Findings suggest a general improvement in instrument performance over that of a decade ago, but sterilization failure rates are still too high. Sterilizer operator errors are a major cause of sterilization failures. BIs are useful in monitoring sterilization performance only when sterilization procedures are performed consistently and competently by well-trained staff using adequately maintained equipment. PMID:1660501

  3. The sterilization of endodontic hand files.

    PubMed

    Hurtt, C A; Rossman, L E

    1996-06-01

    Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments. PMID:8934994

  4. Postpartum Sterilization

    MedlinePlus

    ... sterilization. In tubal sterilization, the fallopian tubes are closed off or removed. Tubal sterilization prevents the egg ... through the incision. The tubes are cut and closed with special thread or removed completely. The incision ...

  5. Spacecraft sterilization.

    NASA Technical Reports Server (NTRS)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  6. Bioequivalent chemical steam sterilization indicators.

    PubMed

    Hirsch, A; Manne, S

    1984-01-01

    Biological indicators used to monitor steam sterilization cycles have two major shortcomings--the incubation period needed to determine if sterilization was accomplished, and the reliance on test packs for gathering information in each load. Chemical indicators do not suffer from these shortcomings. Chemical indicators can respond to time, temperature, and steam parameters to thus parallel the BI reaction. Nine commercially available chemical indicators and four biological indicators were evaluated under the conditions of dry heat, in a biological indicator-evaluator resistometer vessel, and in a hospital sterilizer. The results indicate that wider use of integrated chemical steam sterilization indicators is recommended. PMID:6493101

  7. Reversible Sterilization

    ERIC Educational Resources Information Center

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  8. Sterile technique

    MedlinePlus

    Sterile gloves ... water and soap A sterile kit or pad Gloves (sometimes these are in your kit) A clean, ... border around it. Throw the wrapper away. Your gloves may be separate or inside the kit. To ...

  9. Sterilization System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  10. Review of surface steam sterilization for validation purposes.

    PubMed

    van Doornmalen, Joost; Kopinga, Klaas

    2008-03-01

    Sterilization is an essential step in the process of producing sterile medical devices. To guarantee sterility, the process of sterilization must be validated. Because there is no direct way to measure sterility, the techniques applied to validate the sterilization process are based on statistical principles. Steam sterilization is the most frequently applied sterilization method worldwide and can be validated either by indicators (chemical or biological) or physical measurements. The steam sterilization conditions are described in the literature. Starting from these conditions, criteria for the validation of steam sterilization are derived and can be described in terms of physical parameters. Physical validation of steam sterilization appears to be an adequate and efficient validation method that could be considered as an alternative for indicator validation. Moreover, physical validation can be used for effective troubleshooting in steam sterilizing processes. PMID:18313509

  11. Wind Program Accomplishments

    SciTech Connect

    Wind Program

    2012-05-24

    This fact sheet describes some of the accomplishments of DOE's Wind Program through its investments in technology development and market barrier reduction, and how those accomplishments are supporting the advancement of renewable energy generated using the United States' abundant wind resources.

  12. Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Palazzo, Antonio

    2016-05-01

    Several anomalies recorded in short-baseline neutrino experiments suggest the possibility that the standard 3-flavor framework may be incomplete and point towards a manifestation of new physics. Light sterile neutrinos provide a credible solution to these puzzling results. Here, we present a concise review of the status of the neutrino oscillations within the 3+1 scheme, the minimal extension of the standard 3-flavor framework endowed with one sterile neutrino species. We emphasize the potential role of LBL experiments in the searches of CP violation related to sterile neutrinos and their complementarity with the SBL experiments.

  13. Sterile technique

    MedlinePlus

    ... kit) A clean, dry surface Clean paper towels Wash your hands well and keep all work surfaces ... To open a sterile pad or kit: Wash your hands with soap and running ... palms, fingers, and between your fingers thoroughly. Wash ...

  14. Tubal Sterilization

    MedlinePlus

    ... you feel after the operation depends on your general health, the type of procedure and your tolerance to ... to work after sterilization? That depends on your general health, your attitude, your job and the type of ...

  15. Sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Kopp, J.; Machado, P. A. N.; Maltoni, M.; Schwetz, T.

    2016-06-01

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  16. The Spacelab Accomplishments Forum

    NASA Technical Reports Server (NTRS)

    Emond, J. (Editor); Bennett, N. (Compiler); McCauley, D. (Compiler); Murphy, K. (Compiler)

    2000-01-01

    This document is a record of the Spacelab Accomplishments Forum held in March 1999. Presentations made at the Forum covered the design, engineering, utilization, and science associated with Spacelab, as well as the international associations and impact of Spacelab and its use in the design and utilization of the International Space Station. Topics included Earth observations, space science, life science, commercial uses, microgravity science, and international participation.

  17. Portable Ethylene Oxide Sterilization Chamber

    PubMed Central

    Songer, J. R.; Mathis, R. G.

    1969-01-01

    A portable ethylene oxide sterilization chamber was designed, constructed, and tested for use in the sterilization of embolectomy catheters. The unit can accommodate catheters up to 40 inches (101.6 cm) in length and can be operated for less than 4 cents per cycle. A constant concentration of 500 mg of ethylene oxide per liter of space and holding periods of 4 and 6 hr at 43 and 22 C, respectively, were adequate when tested with B. subtilis spores. The estimated cost of construction was $165.00. If temperature control is unnecessary, the cost is approximately $80.00. Images PMID:4977644

  18. Life sciences accomplishments

    NASA Technical Reports Server (NTRS)

    1985-01-01

    From its inception, the main charter of Life Sciences has been to define biomedical requirements for the design and development of spacecraft systems and to participate in NASA's scientific exploration of the universe. The role of the Life Sciences Division is to: (1) assure the health, well being and productivity of all individuals who fly in space; (2) study the origin, evolution, and distribution of life in the universe; and (3) to utilize the space environment as a tool for research in biology and medicine. The activities, programs, and accomplishments to date in the efforts to achieve these goals are detailed and the future challenges that face the division as it moves forward from the shuttle era to a permanent manned presence in space space station's are examined.

  19. Life Sciences Accomplishments 1994

    NASA Technical Reports Server (NTRS)

    Burnell, Mary Lou (Editor)

    1993-01-01

    proposals for ground-based and flight research for all programs. Areas of particular interest to NASA were defined Proposals due April 29, 1994, will be peer reviewed - externally for scientific merit. This annual NRA process is now the mechanism for recruiting both extramural and intramural investigations. As an overview of LBSAD activities in 1993, this accomplishments document covers each of the major organizational components of the Division and the accomplishments of each. The second section is a review of the Space Life Sciences Research programs Space Biology, Space Physiology and Countermeasures, Radiation Health, Environmental Health, Space Human Factors, Advanced Life Support, and Global Monitoring and Disease Prediction, The third section, Research in Space Flight, describes the substantial contributions of the Spacelab Life Sciences 2 (SLS-2) mission to life sciences research and the significant contributions of the other missions flown in 1993, along with plans for future missions. The Division has greatly expanded and given high priority to its Education and Outreach Programs, which are presented in the fourth section. The fifth and final section, Partners for Space, shows the Divisions Cooperative efforts with other national and international agencies to achieve common goals, along with the accomplishments of joint research and analysis programs.

  20. EFRC CMSNF Major Accomplishments

    SciTech Connect

    D. Hurley; Todd R. Allen

    2014-09-01

    The mission of the Center for Material Science of Nuclear Fuels (CMSNF) has been to develop a first-principles-based understanding of thermal transport in the most widely used nuclear fuel, UO2, in the presence of defect microstructure associated with radiation environments. The overarching goal within this mission was to develop an experimentally validated multiscale modeling capability directed toward a predictive understanding of the impact of radiation and fission-product induced defects and microstructure on thermal transport in nuclear fuel. Implementation of the mission was accomplished by integrating the physics of thermal transport in crystalline solids with microstructure science under irradiation through multi institutional experimental and computational materials theory teams from Idaho National Laboratory, Oak Ridge National Laboratory, Purdue University, the University of Florida, the University of Wisconsin, and the Colorado School of Mines. The Center’s research focused on five major areas: (i) The fundamental aspects of anharmonicity in UO2 crystals and its impact on thermal transport; (ii) The effects of radiation microstructure on thermal transport in UO2; (iii) The mechanisms of defect clustering in UO2 under irradiation; (iv) The effect of temperature and oxygen environment on the stoichiometry of UO2; and (v) The mechanisms of growth of dislocation loops and voids under irradiation. The Center has made important progress in each of these areas, as summarized below.

  1. Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.

    PubMed

    Karoshi, Mahantesh; Yoong, Wai

    2004-01-01

    In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure. PMID:15481482

  2. NASA space biology accomplishments, 1982

    NASA Technical Reports Server (NTRS)

    Halstead, T. W.; Pleasant, L. G.

    1983-01-01

    Summaries of NASA's Space Biology Program projects are provided. The goals, objectives, accomplishments, and future plans of each project are described in this publication as individual technical summaries.

  3. Parameters governing steam sterilization of deadlegs.

    PubMed

    Young, J H; Ferko, B L; Gaber, R P

    1994-01-01

    Use of saturated steam for sterilization-in-place (SIP) is limited by factors effecting displacement of air from deadlegs. Effects of tube diameter, length, orientation and position within a deadleg were quantitatively studied by examining temperature profiles and rates of kill of Bacillus stearothermophilus spores. Tube diameter had the greatest effect on sterilization. For small diameter tubes, 0.4 cm inside diameter (ID), air displacement was minimal and due mainly to diffusion. 8.8 cm long tubes with 0.4 cm IDs could not be sterilized at 121 degrees C. As tube diameter was increased and buoyant driven convective flow became dominant over viscous forces, sterilization was achieved and tube orientation became critical. Sterilization time, as defined by a twelve log reduction in spore population, was 75 minutes in a 19.0 cm long vertical tube with 1.7 cm ID, whereas 167 minutes were required for an 8.8 cm long tube with 1.0 cm ID. For 8.8 cm long tubes, only the 1.7 cm ID tube could be sterilized when orientated 5 degrees above horizontal. Data show that length to diameter ratios, L/Ds, do not provide a general guideline which can be used to predict sterilization. In the absence of steam bleeders, equipment should be designed to assure strong buoyancy driven convective flow to assure adequate air removal. This requires elimination of small diameter deadlegs (0.4 cm ID and less) and vertical positioning of deadlegs. PMID:8069515

  4. Sterilizing the Poor

    ERIC Educational Resources Information Center

    Rothman, Sheila M.

    1977-01-01

    Suggests that freedom for the middle classes may mean vulnerability for the poor. The enthusiasm for sterilization may be so intense as to deprive the poor of their right not to be sterilized. (Author/AM)

  5. Apparatus Circulates Sterilizing Gas

    NASA Technical Reports Server (NTRS)

    Cross, John H.; Schwarz, Ray P.

    1991-01-01

    Apparatus circulates sterilizing gas containing ethylene oxide and chlorofluorocarbon through laboratory or medical equipment. Confines sterilizing gas, circulating it only through parts to be treated. Consists of two units. One delivers ethylene oxide/chlorofluorocarbon gas mixture and removes gas after treatment. Other warms, humidifies, and circulates gas through equipment to be treated. Process provides reliable sterilization with negligible residual toxicity from ethylene oxide. Particularly suitable for sterilization of interiors of bioreactors, heart/lung machines, dialyzers, or other equipment including complicated tubing.

  6. ISO radiation sterilization standards

    NASA Astrophysics Data System (ADS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-06-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, "Radiation Sterilization Material Qualification" 2. ISO TR 13409-1996, "Sterilization of health care products — Radiation sterilization — Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches" 3. ISO Draft TR, "Sterilization of health care products — Radiation sterilization Selection of a sterilization dose for a single production batch" li]4. ISO Draft TR, "Sterilization of health care products — Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits."

  7. Sterilization of slide sheath anesthetic injection systems placed within sharps containers.

    PubMed

    Palenik, C J; Burke, F J; Bose, M; Altweis, M L

    1997-01-01

    The purpose of this study was to evaluate the effect that two steam autoclaves and an unsaturated chemical vapor sterilizer had on killing bacterial endospores present on commercial spore strips or applied to sterile anesthetic injection systems placed within sharps containers. Three types of sterilizers were used: a gravity steam autoclave, a high vacuum steam autoclave and an unsaturated chemical vapor sterilizer. The microbial challenge for the sterilizers were Bacillus stearothermophilus spores present on commercial spore strips or drawn into and applied onto sliding sheath anesthetic injection systems with anesthetic carpules attached. Spore-soiled items were placed into the middle of sharps containers three-quarters-filled with representative clinical waste and sterilized. If, after culturing, sterilization of all test items in a group was not achieved, additional sterilization time was applied. Spore strips were killed within a single cycle of each sterilizer. Spore-soiled injection systems and carpules could not be routinely sterilized in the gravity steam autoclave or unsaturated chemical vapor sterilizers, even after three consecutive sterilization cycles. These items, however, were sterilized by exposure to a single-treatment cycle in a high-vacuum steam autoclave. Results indicate that routine sterilization of spore contaminated anesthetic carpules or injection systems could not be accomplished in a reasonable amount of time using sterilizers commonly found in dental offices. PMID:9517339

  8. Advanced Fuels Campaign 2012 Accomplishments

    SciTech Connect

    Not Listed

    2012-11-01

    The Advanced Fuels Campaign (AFC) under the Fuel Cycle Research and Development (FCRD) program is responsible for developing fuels technologies to support the various fuel cycle options defined in the DOE Nuclear Energy Research and Development Roadmap, Report to Congress, April 2010. The fiscal year 2012 (FY 2012) accomplishments are highlighted below. Kemal Pasamehmetoglu is the National Technical Director for AFC.

  9. Infant Mortality: 1989 Research Accomplishments.

    ERIC Educational Resources Information Center

    National Inst. of Child Health and Human Development (NIH), Bethesda, MD.

    Collected in this document are reports of the National Institutes of Health's 1989 accomplishments in research on the problem of infant mortality. Reports are provided by the: (1) National Institute of Child Health and Human Development; (2) National Cancer Institute; (3) National Heart, Lung, and Blood Institute; (4) National Institute of…

  10. The Joint Accomplishment of Identity

    ERIC Educational Resources Information Center

    Hand, Victoria; Gresalfi, Melissa

    2015-01-01

    Identity has become a central concept in the analysis of learning from social perspectives. In this article, we draw on a situative perspective to conceptualize identity as a "joint accomplishment" between individuals and their interactions with norms, practices, cultural tools, relationships, and institutional and cultural contexts.…

  11. Female Tubal Sterilization

    PubMed Central

    Rowe, Timothy C.; Pabuccu, Recai

    1986-01-01

    Tubal ligation has become the second most popular method of contraception in Canada, after oral contraception. Refinement of techniques has resulted in sterilization procedures which have minimal potential for failure and high potential for reversibility. Laparoscopic and minilaparatomy techniques allow outpatient “Band-Aid” sterilizations with less risk of complications than more destructive procedures. Laparoscopic application of tubal clips or rings is highly effective, with minimal tubal destruction. Tubal ligation following a pregnancy is more often regretted than is interval sterilization. The search continues for a satisfactory transcervical sterilization procedure. PMID:21267115

  12. Sterilization for Women and Men

    MedlinePlus

    ... are rare. Can sterilization be reversed? Sterilization is permanent birth control and is not meant to be reversible. Before ... that can fertilize a female egg. Sterilization: A permanent method of birth control. Testes: Two male organs that produce sperm and ...

  13. Vaporized hydrogen peroxide sterilization of freeze dryers.

    PubMed

    Johnson, J W; Arnold, J F; Nail, S L; Renzi, E

    1992-01-01

    The feasibility of using vapor hydrogen peroxide (VHP) as an alternative to steam sterilization has been examined using a pilot plant freeze dryer equipped with a prototype vapor generator. Specific objectives of the study discussed in this presentation were to: 1. Identify critical process variables affecting the lethality of VHP to Bacillus stearothermophilus spores, particularly within dead legs in the system. 2. Measure the efficacy of system degassing after sterilization. 3. Determine the effect of repeated sterilization cycles on the integrity of elastomeric components of the freeze dryer. Penetration of adequate concentrations of hydrogen peroxide vapor into small diameter piping, such as tubing connected to pressure gauges, is the most challenging aspect of VHP sterilization of freeze dryers. Prior to equipment modifications, spore strips placed within such dead legs remained positive irrespective of the number of gas/degas pulses and system pressure. Equipment modifications necessary to effect complete kill of biological indicators placed in system dead legs is discussed. Results of this study support the conclusion that vaporized hydrogen peroxide shows promise as an alternative sterilization method for freeze dryers. PMID:1474433

  14. [Sterilization and eugenics].

    PubMed

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties. PMID:22164927

  15. Activities and Accomplishments of ICAM

    NASA Technical Reports Server (NTRS)

    Tiwari, S. N.

    1997-01-01

    A brief historical background on establishing the Institute for Computational and Applied Mechanics (ICAM) is presented and basic goals and objectives are discussed. It is emphasized that the goal of the ICAM has been to develop and maintain a self-sustaining center of excellence in computational methods at Old Dominion University (ODU). Information is provided on funding sources and budget disposition, recent activities and accomplishments, list of graduate students supported on the program, and number of students who received graduate degrees (M.S. as well as Ph.D.). Information is also provided on research coordination with various scientists and engineers, and on different reports specifically written for ICAM. ICAM has been supported, in part, by NASA Langley Research Center through Grant NAG-1-363. This report constitutes the final report for ICAM for the period ending December 1996. The grant has been monitored by the University Affairs Officers at NASA Langley.

  16. 21 CFR 1404.900 - Adequate evidence.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Adequate evidence. 1404.900 Section 1404.900 Food and Drugs OFFICE OF NATIONAL DRUG CONTROL POLICY GOVERNMENTWIDE DEBARMENT AND SUSPENSION (NONPROCUREMENT) Definitions § 1404.900 Adequate evidence. Adequate evidence means information sufficient to support the reasonable belief that a particular...

  17. 29 CFR 98.900 - Adequate evidence.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Adequate evidence. 98.900 Section 98.900 Labor Office of the Secretary of Labor GOVERNMENTWIDE DEBARMENT AND SUSPENSION (NONPROCUREMENT) Definitions § 98.900 Adequate evidence. Adequate evidence means information sufficient to support the reasonable belief that a...

  18. Female Sterilization (Tubal Ligation)

    MedlinePlus

    ... when you want to have it done. Some women are sterilized right after they have a baby or an abortion, ... videos on Youtube © 1998-2016 | Center for Young Women's Health, Boston Children's Hospital. All rights reserved.

  19. Sterilization of space hardware.

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  20. Sterilization by Laparoscopy

    MedlinePlus

    ... sleep-like state to prevent pain during surgery. Human Immunodeficiency Virus (HIV): A virus that attacks certain cells of the body’s immune system and causes acquired immunodeficiency syndrome (AIDS). Hysteroscopic Sterilization: ...

  1. Sterilization: A Review and Update.

    PubMed

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. PMID:26598311

  2. Auditing radiation sterilization facilities

    NASA Astrophysics Data System (ADS)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  3. ADVANCED FUELS CAMPAIGN 2013 ACCOMPLISHMENTS

    SciTech Connect

    Not Listed

    2013-10-01

    The mission of the Advanced Fuels Campaign (AFC) is to perform Research, Development, and Demonstration (RD&D) activities for advanced fuel forms (including cladding) to enhance the performance and safety of the nation’s current and future reactors; enhance proliferation resistance of nuclear fuel; effectively utilize nuclear energy resources; and address the longer-term waste management challenges. This includes development of a state-of-the art Research and Development (R&D) infrastructure to support the use of “goal-oriented science-based approach.” In support of the Fuel Cycle Research and Development (FCRD) program, AFC is responsible for developing advanced fuels technologies to support the various fuel cycle options defined in the Department of Energy (DOE) Nuclear Energy Research and Development Roadmap, Report to Congress, April 2010. Accomplishments made during fiscal year (FY) 2013 are highlighted in this report, which focuses on completed work and results. The process details leading up to the results are not included; however, the technical contact is provided for each section.

  4. Hysteroscopic Tubal Sterilization

    PubMed Central

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  5. Microwave continuous sterilization of injection ampoules.

    PubMed

    Sasaki, K; Honda, W; Shimizu, K; Iizima, K; Ehara, T; Okuzawa, K; Miyake, Y

    1996-01-01

    A new microwave continuous sterilizer (MWS) for applying microwave dielectric heating as an alternative to an autoclave was developed. The developmental objectives of the MWS were: 1. Achieving sufficient sterilization for the drugs containing heat-sensitive ingredients. 2. Measuring and recording sterilization temperature of each ampoule. 3. Ensuring automatic continuous operation and linkage with the preceding and following machines in an injection ampoule production process. The temperature of the drug solution in an ampoule was heated to 140 degrees C within about 30 seconds by the MWS. Target F0 value is achieved through the maintaining heater to maintain the target temperature for 12 seconds. Ampoules are cooled with air and water after completion of heating. The MWS is capable of processing 150 ampoules per minute. The newly developed techniques which minimized temperature distribution of heated ampoule solution were: 1. Microwave irradiation in a direction opposite to the direction of ampoules transportation. 2. Microwave irradiation in the lower part of ampoule solution (i.e., heating up the drug solution by thermal convection.) 3. Microwave power control by feedback of measured temperatures. 4. Heating rate control corresponding to the dielectric property of ampoule solution. The drug stability test was performed using 3% pyridoxamine phosphate solution, and the inactivation of spores in 3% pyridoxamine phosphate solution was examined using Bacillus stearothermophilus ATCC 7953 spores. The MWS was proved to have an adequate efficiency of sterilization with less chemical degradation of the contents than an autoclave. PMID:8696781

  6. Space Biophysics: Accomplishments, Trends, Challenges

    NASA Technical Reports Server (NTRS)

    Smith, Jeffrey D.

    2015-01-01

    the protective environment of Earth, the biophysical properties underlying these changes must be studied, characterized and understood. This lecture reviews the current state of NASA biophysics research accomplishments and identifies future trends and challenges for biophysics research on the International Space Station and beyond.

  7. Effectiveness of steam sterilization on the contents of sharps containers.

    PubMed

    Palenik, C J; Riggen, S D; Celis, L J; Sheldrake, M A; Miller, C H

    1992-01-01

    The purpose of this study was to evaluate the killing effect that treatment in gravity or high-vacuum steam autoclaves had on endospores present on strips or applied to dental needles within 10 types of small sharps containers. Spore strips containing Bacillus stearothermophilus endospores were used, while needles were soiled with an equal number of spores or with spores mixed with blood. Needles were tested capped and uncapped. Strips and needles were autoclaved in empty and 3/4 filled containers placed in several orientations (vents open or closed, upward or on-side). If sterilization was not accomplished within the initial period, additional exposure time was added up to a one hour maximum. Major findings for gravity autoclaves were: 1) strips and needles present in empty containers could, in most cases, be sterilized within 15 minutes when the vents were left open and the containers were placed on-side; 2) spore- and spore plus blood-soiled needles were more difficult to sterilize then were commercial spore strips; 3) capping of needles and the presence of blood did not decrease sterilization efficiency; 4) sterilization in the presence of fill material required additional exposure times and 5) larger containers (greater than 500 ml volume) were more difficult to sterilize than were the smaller (250 ml) ones. All type of open-vented, filled containers could be sterilized within 10 minutes in a high-vacuum autoclave. PMID:1499239

  8. The emergence of load-oriented sterilization.

    PubMed

    Kolstad, R A

    1994-01-01

    Achieving maximum equipment sterilization is critical. Factors that contribute to sterilization efficiency are covered, including sterilization accuracy level, chamber loading and biological indicators. PMID:8031354

  9. Assessing Accomplished Teaching: Good Strides, Great Challenges

    ERIC Educational Resources Information Center

    Norman, Antony D.

    2010-01-01

    This article surveys efforts at the national and international level to define and assess accomplished teaching with particular attention devoted to how assessments of accomplished teaching connect to student learning. The author finds that most assessments are based on aspects of teaching that, presumably, come together as accomplished teaching.…

  10. 34 CFR 85.900 - Adequate evidence.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Definitions § 85.900 Adequate evidence. Adequate evidence means information sufficient to support the reasonable belief that a particular act or omission has occurred. Authority: E.O. 12549 (3 CFR, 1986 Comp., p. 189); E.O 12689 (3 CFR, 1989 Comp., p. 235); 20 U.S.C. 1082, 1094, 1221e-3 and 3474; and Sec....

  11. 29 CFR 452.110 - Adequate safeguards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 2 2010-07-01 2010-07-01 false Adequate safeguards. 452.110 Section 452.110 Labor... DISCLOSURE ACT OF 1959 Election Procedures; Rights of Members § 452.110 Adequate safeguards. (a) In addition to the election safeguards discussed in this part, the Act contains a general mandate in section...

  12. 29 CFR 452.110 - Adequate safeguards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 2 2011-07-01 2011-07-01 false Adequate safeguards. 452.110 Section 452.110 Labor... DISCLOSURE ACT OF 1959 Election Procedures; Rights of Members § 452.110 Adequate safeguards. (a) In addition to the election safeguards discussed in this part, the Act contains a general mandate in section...

  13. Karlson ozone sterilizer. Final report

    SciTech Connect

    Karlson, E.

    1984-05-07

    The authors have a functional sterilization system employing ozone as a sterilization agent. This final report covers the work that led to the first medical sterilizer using ozone as the sterilizing agent. The specifications and the final design were set by hospital operating room personnel and public safety standards. Work on kill tests using bacteria, viruses and fungi determined the necessary time and concentration of ozone necessary for sterilization. These data were used in the Karlson Ozone Sterilizer to determine the length of the steps of the operating cycle and the concentration of ozone to be used. 27 references.

  14. Light sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Gariazzo, S.; Giunti, C.; Laveder, M.; Li, Y. F.; Zavanin, E. M.

    2016-03-01

    The theory and phenomenology of light sterile neutrinos at the eV mass scale is reviewed. The reactor, gallium and Liquid Scintillator Neutrino Detector anomalies are briefly described and interpreted as indications of the existence of short-baseline oscillations which require the existence of light sterile neutrinos. The global fits of short-baseline oscillation data in 3 + 1 and 3 + 2 schemes are discussed, together with the implications for β-decay and neutrinoless double-β decay. The cosmological effects of light sterile neutrinos are briefly reviewed and the implications of existing cosmological data are discussed. The review concludes with a summary of future perspectives. This review is dedicated to the memory of Hai-Wei Long, our dear friend and collaborator, who passed away on 29 May 2015. He was an exceptionally kind person and an enthusiastic physicist. We deeply miss him.

  15. Light sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Gariazzo, S.; Giunti, C.; Laveder, M.; Li, Y. F.; Zavanin, E. M.

    2015-03-01

    The theory and phenomenology of light sterile neutrinos at the eV mass scale is reviewed. The reactor, gallium and Liquid Scintillator Neutrino Detector anomalies are briefly described and interpreted as indications of the existence of short-baseline oscillations which require the existence of light sterile neutrinos. The global fits of short-baseline oscillation data in 3 + 1 and 3 + 2 schemes are discussed, together with the implications for β-decay and neutrinoless double-β decay. The cosmological effects of light sterile neutrinos are briefly reviewed and the implications of existing cosmological data are discussed. The review concludes with a summary of future perspectives. This review is dedicated to the memory of Hai-Wei Long, our dear friend and collaborator, who passed away on 29 May 2015. He was an exceptionally kind person and an enthusiastic physicist. We deeply miss him.

  16. Continuous sterilization of plumbing systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Moyers, C. V.; Wright, E. E., Jr.

    1979-01-01

    Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.

  17. Sterilization surgery - making a decision

    MedlinePlus

    ... have sterilization surgery. However, some may regret the decision later. Men or women who are younger at ... the options available to you before making the decision to have a sterilization procedure.

  18. MINOS Sterile Neutrino Search

    SciTech Connect

    Koskinen, David Jason

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  19. Sterilization of Native Americans

    ERIC Educational Resources Information Center

    Dillingham, Brint

    1977-01-01

    The U.S. State Department's Agency for International Development (AID) is spending more than $143 million this year for population control measures in over 70 nations around the world and it is estimated that as much as $10 million was spent in one year for surgical sterilization procedures. (JC)

  20. Radiation sterilization of ketoprofen

    NASA Astrophysics Data System (ADS)

    Katušin-Ražem, Branka; Hamitouche, Katia; Maltar-Strmečki, Nadica; Kos, Karmen; Pucić, Irina; Britvić-Budicin, Smiljana; Ražem, Dušan

    2005-06-01

    Radiation sterilization of ketoprofen (KP) dry powder was investigated by selected physico-chemical methods. High-performance liquid chromatography, ultraviolet spectrophotometry, infrared spectrophotometry, differential scanning calorimetry, X-ray diffraction and electron spin resonance spectroscopy did not show any significant degradation at sterilization dose 25 kGy. To determine the nature, extent and direction of radiation-induced changes, KP was irradiated to extremely high doses, much higher than necessary to achieve sterility. The irradiated KP did not show any difference of XRD patterns up to 200 kGy; with DSC and IR some changes were detected only above 1000 and 2000 kGy, respectively; HPLC has shown about 5% destruction at 2000 kGy. Acetyl benzophenon (AcBph) was generated by irradiation with G(AcBph)=(1.6±0.1)×10 -8 mol J -1. Ames test has shown no mutagenicity of KP irradiated with 3000 kGy or of the oily mixure of radiolytic products isolated from it. Solid KP has proven to be very stable on irradiation, and irradiation has been found to be a suitable method for its sterilization.

  1. Dark matter and sterility

    NASA Astrophysics Data System (ADS)

    Smith, Peter F.

    2014-10-01

    In reply to Louise Mayor's dark-matter flow-chart "What's the matter?" (July pp30-31), which summarized the most likely candidates for galactic dark matter, and to Jon Cartwright's feature "A fourth type of neutrino" on the possibility of "sterile" neutrinos (August pp24-28).

  2. Americans Getting Adequate Water Daily, CDC Finds

    MedlinePlus

    ... medlineplus/news/fullstory_158510.html Americans Getting Adequate Water Daily, CDC Finds Men take in an average ... new government report finds most are getting enough water each day. The data, from the U.S. National ...

  3. Americans Getting Adequate Water Daily, CDC Finds

    MedlinePlus

    ... gov/news/fullstory_158510.html Americans Getting Adequate Water Daily, CDC Finds Men take in an average ... new government report finds most are getting enough water each day. The data, from the U.S. National ...

  4. Sterility of packaged implant components.

    PubMed

    Worthington, Philip

    2005-01-01

    Several implant components in their original glass vial and peel-back packages were subjected to sterility testing to determine whether the contents remained sterile after the expiration date marked on the package had passed. The results from a university microbiology laboratory showed that the contents remained sterile for 6 to 11 years after the expiration dates. PMID:15973959

  5. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  6. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  7. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  8. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  9. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  10. Effectiveness of three types of sterilization on the contents of sharps containers.

    PubMed

    Sheldrake, M A; Majors, C D; Gaines, D J; Palenik, C J

    1995-11-01

    The purpose of this study was to test the effect of treatment in a gravity steam autoclave, high-vacuum steam autoclave, or an unsaturated chemical vapor sterilizer on endospores present on strips or placed inside of dental anesthetic cartridges held within sharps containers. Strips with 1.7 X 10(5) Bacillus stearothermophilus endospores were used; the cartridges were soiled with an equal number of spores or spores mixed with blood. If sterilization was not accomplished after the initial period, additional exposure time was added. Neither the presence of blood or anesthetic solution nor the position of the container affected the efficiency of sterilization. Soiled cartridges were much more difficult than strips to sterilize. Intact cartridges could not be sterilized by two runs in a gravity steam autoclave or an unsaturated chemical vapor sterilizer or one run in a high-vacuum steam autoclave. Sterilization occurred after two runs in the gravity steam autoclave and unsaturated chemical vapor sterilizer only when one end of the cartridge was removed prior to processing. Results indicated that unopened spore-soiled cartridges are not readily sterilized by commonplace office sterilizers, even after extended exposure. PMID:8628836

  11. Sterile neutrino anarchy

    NASA Astrophysics Data System (ADS)

    Heeck, Julian; Rodejohann, Werner

    2013-02-01

    Lepton mixing, which requires physics beyond the Standard Model, is surprisingly compatible with a minimal, symmetryless and unbiased approach, called anarchy. This contrasts with highly involved flavor symmetry models. On the other hand, hints for light sterile neutrinos have emerged from a variety of independent experiments and observations. If confirmed, their existence would represent a groundbreaking discovery, calling for a theoretical interpretation. We discuss anarchy in the two-neutrino eV-scale seesaw framework. The distributions of mixing angles and masses according to anarchy are in agreement with global fits for the active and sterile neutrino parameters. Our minimal and economical scenario predicts the absence of neutrinoless double beta decay and one vanishing neutrino mass, and can therefore be tested in future experiments.

  12. Transmutation Fuels Campaign FY-09 Accomplishments Report

    SciTech Connect

    Lori Braase

    2009-09-01

    This report summarizes the fiscal year 2009 (FY-08) accomplishments for the Transmutation Fuels Campaign (TFC). The emphasis is on the accomplishments and relevance of the work. Detailed description of the methods used to achieve the highlighted results and the associated support tasks are not included in this report.

  13. Immediate Sterility after Vasectomy

    PubMed Central

    Hay, D. Urquhart

    1973-01-01

    A 2·5-ml injection of 1/1,000 solution of euflavine given down each vas during vasectomy for sterilization will destroy all sperms within the semen and eliminate the necessity for examining two consecutive specimens of semen for azoospermia after the operation. No local inflammatory response has been observed in the seminal vesicles or prostate of 81 consecutive patients in whom the method has been used. PMID:4730187

  14. Asbestos/NESHAP adequately wet guidance

    SciTech Connect

    Shafer, R.; Throwe, S.; Salgado, O.; Garlow, C.; Hoerath, E.

    1990-12-01

    The Asbestos NESHAP requires facility owners and/or operators involved in demolition and renovation activities to control emissions of particulate asbestos to the outside air because no safe concentration of airborne asbestos has ever been established. The primary method used to control asbestos emissions is to adequately wet the Asbestos Containing Material (ACM) with a wetting agent prior to, during and after demolition/renovation activities. The purpose of the document is to provide guidance to asbestos inspectors and the regulated community on how to determine if friable ACM is adequately wet as required by the Asbestos NESHAP.

  15. Sterilization by oxygen plasma

    NASA Astrophysics Data System (ADS)

    Moreira, Adir José; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Zambon, Luis da Silva; da Silva, Mônica Valero; Verdonck, Patrick Bernard

    2004-07-01

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  16. [Sterilization of women].

    PubMed

    Tandberg, A

    1988-01-30

    The records of 209 women sterilized in the Lillehammer (Norway) county hospital during the period 1980-82 were examined for age, residence, parity, method of operation, induced abortions and frequency of complications. The patients were sent a questionnaire 6 months after the operation and were asked about how long they had felt unable to work after the operation, whether they regretted the operation, and whether they were satisfied with the cosmetic results. 96% of the patients returned the questionnaires. On the average the women had had 2.4 children at the time of sterilization. Those who had received induced abortions at the same time had 2.5 children. Women resident in the city had 2.1 children, those in the country had 2.4 children. None had 6 children. 20% had received abortion simultaneously. Aside from 1 patient who had transitory paresis in the left arm due to faulty padding in a shoulder support, there were no complications noted in the material. 2 patients regretted the operation. Neither of them had had simultaneous abortion. 1 of these had 1 child. Advised to be sterilized because of severe preeclampsia in her 1st pregnancy, she desired more children. The other, who had 4 children, gave decreased libido as the cause for her regret. Of the 177 who had had laparoscopy, only 6 patients (3.5%) said that they were dissatisfied with the appearance of the scar. PMID:3353913

  17. Effects of steam sterilization on thermogelling chitosan-based gels.

    PubMed

    Jarry, C; Chaput, C; Chenite, A; Renaud, M A; Buschmann, M; Leroux, J C

    2001-01-01

    A new thermogelling chitosan-glycerophosphate system has been recently proposed for biomedical applications such as drug and cell delivery. The objectives of this work were to characterize the effect of steam sterilization on the in vitro and in vivo end performances of the gel and to develop a filtration-based method to assess its sterility. Autoclaving 2% (w/v) chitosan solutions for as short as 10 min resulted in a 30% decrease in molecular weight, 3-5-fold decrease in dynamic viscosity, and substantial loss of mechanical properties of the resulting gel. However, sterilization did not impair the ability of the system to form a gel at 37 degrees C. The antimicrobial activity of chitosan against several microorganisms was evaluated after inoculation of chitosan solutions and removal of the cells by filtration. It was found that, although chitosan was bacteriostatic against the heat sterilization bioindicator Bacillus stearothermophilus, the bacteria could rapidly grow after separation from the chitosan solution by filtration. This indicated that B. stearothermophilus is an adequate strain to validate a heat sterilization method on chitosan preparations, and accordingly this strain was used to assess the sterility of chitosan solution following a 10 min autoclaving time. PMID:11153009

  18. Sterilization, high-level disinfection, and environmental cleaning.

    PubMed

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. PMID:21315994

  19. Adequate supervision for children and adolescents.

    PubMed

    Anderst, James; Moffatt, Mary

    2014-11-01

    Primary care providers (PCPs) have the opportunity to improve child health and well-being by addressing supervision issues before an injury or exposure has occurred and/or after an injury or exposure has occurred. Appropriate anticipatory guidance on supervision at well-child visits can improve supervision of children, and may prevent future harm. Adequate supervision varies based on the child's development and maturity, and the risks in the child's environment. Consideration should be given to issues as wide ranging as swimming pools, falls, dating violence, and social media. By considering the likelihood of harm and the severity of the potential harm, caregivers may provide adequate supervision by minimizing risks to the child while still allowing the child to take "small" risks as needed for healthy development. Caregivers should initially focus on direct (visual, auditory, and proximity) supervision of the young child. Gradually, supervision needs to be adjusted as the child develops, emphasizing a safe environment and safe social interactions, with graduated independence. PCPs may foster adequate supervision by providing concrete guidance to caregivers. In addition to preventing injury, supervision includes fostering a safe, stable, and nurturing relationship with every child. PCPs should be familiar with age/developmentally based supervision risks, adequate supervision based on those risks, characteristics of neglectful supervision based on age/development, and ways to encourage appropriate supervision throughout childhood. PMID:25369578

  20. Small Rural Schools CAN Have Adequate Curriculums.

    ERIC Educational Resources Information Center

    Loustaunau, Martha

    The small rural school's foremost and largest problem is providing an adequate curriculum for students in a changing world. Often the small district cannot or is not willing to pay the per-pupil cost of curriculum specialists, specialized courses using expensive equipment no more than one period a day, and remodeled rooms to accommodate new…

  1. Funding the Formula Adequately in Oklahoma

    ERIC Educational Resources Information Center

    Hancock, Kenneth

    2015-01-01

    This report is a longevity, simulational study that looks at how the ratio of state support to local support effects the number of school districts that breaks the common school's funding formula which in turns effects the equity of distribution to the common schools. After nearly two decades of adequately supporting the funding formula, Oklahoma…

  2. Hysteroscopic Tubal Sterilization

    PubMed Central

    2013-01-01

    Background Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. Objectives The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. Data Sources A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Review Methods Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. Results A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. Limitations All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Conclusions Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Plain Language Summary Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal

  3. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  4. Wind Energy Program: Top 10 Program Accomplishments

    SciTech Connect

    2009-01-18

    Brochure on the top accomplishments of the Wind Energy Program, including the development of large wind machines, small machines for the residential market, wind tunnel testing, computer codes for modeling wind systems, high definition wind maps, and successful collaborations.

  5. Accomplishments of Science by the Year 2000

    NASA Technical Reports Server (NTRS)

    Bergman, J.

    1985-01-01

    Current and projected accomplishments in science and technology are examined from a social and political perspective. It is observed that the present level of research and development in the United States is inadequate for many possible advancements to occur.

  6. New disinfection and sterilization methods.

    PubMed Central

    Rutala, W. A.; Weber, D. J.

    2001-01-01

    New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50). PMID:11294738

  7. Electrolytic silver ion cell sterilizes water supply

    NASA Technical Reports Server (NTRS)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  8. Sterilization of Extracted Human Teeth.

    ERIC Educational Resources Information Center

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  9. Engineering Accomplishments in the Construction of NCSX

    SciTech Connect

    G. H. Neilson; P.J. Heitzenroeder; B.E. Nelson; W.T. Reiersen; A. Brooks; T.G. Brown; J.H. Chrzanowski; M.J. Cole; F. Dahlgren; T. Dodson; L.E. Dudek; R.A. Ellis; H.M. Fan; P.J. Fogarty; K.D. Freudenberg; P.L. Goranson; J.H. Harris; M.R. Kalish; G. Labik; J.F. Lyon; N. Pomphrey; C.D. Priniski; S. Raftopoulos; D.J. Rej; W.R. Sands; R.T. Simmons; B.E. Stratton; R.L. Strykowsky; M.E. Viola; D.E. Williamson; M.C. Zarnstorff

    2008-09-01

    The National Compact Stellarator Experiment (NCSX) was designed to test a compact, quasiaxisymmetric stellarator configuration. Flexibility and accurate realization of its complex 3D geometry were key requirements affecting the design and construction. While the project was terminated before completing construction, there were significant engineering accomplishments in design, fabrication, and assembly. The design of the stellarator core device was completed. All of the modular coils, toroidal field coils, and vacuum vessel sectors were fabricated. Critical assembly steps were demonstrated. Engineering advances were made in the application of CAD modeling, structural analysis, and accurate fabrication of complex-shaped components and subassemblies. The engineering accomplishments of the project are summarized

  10. [Sterility in medieval noblemen].

    PubMed

    van Eickels, Klaus

    2009-01-01

    The social competence of the medieval nobleman was closely associated with his male sense of honour. One essential aspect of his masculinity was the ability to produce progeny. The childlessness of a good ruler needed special justification, the childlessness of a bad ruler was seen as God's punishment. In terms of canon law, the inability to procreate was irrelevant as long as the marriage could be consummated. Considering the importance of the procreative capacity and its symbolic significance one must ask to what extent it was possible to ascertain sterility in the Middle Ages. In the case of noblemen one can assume that they could obtain certainty about their fertility through their premarital and extramarital intercourse. This might explain why some rulers and nobles accepted a childless marriage without deeming it necessary to take another wife (or plan their itinerary in a way that enabled them to produce progeny). PMID:20506725

  11. Conditional sterility in plants

    DOEpatents

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  12. Release of bacteria during the purge cycles of steam-jacketed sterilizers.

    PubMed

    Marshall, B M; Shin-Kim, H; Perlov, D; Levy, S B

    1999-01-01

    The design of the steam-jacketed sterilizer includes an exterior air-gap fixture through which purged chamber aerosols potentially could escape into the ambient environment. Studies of the purge cycle in two sterilizer models tested the potential release of a genetically marked Enterococcus faecalis, together with Bacillus stearothermophilus spores introduced as exposed cultures. Direct plate counts, broth enrichment and polymerase chain reaction analysis were used to confirm any released organisms trapped in an all-glass impinger. From the retrieval of both bacterial strains, an estimated 10(3) organisms can be released from uncontained bacterial loads of 10(11) E. faecalis and 10(7) B. stearothermophilus, even from properly functioning autoclaves. The release of an opportunistic pathogen from sterilizer purge exhausts emphasises the importance of proper sterilizer location, ventilation, containment of heavily contaminated loads, and adequate sterilizer maintenance. PMID:10795367

  13. Accomplishing Multiple Goals through Community Connections

    ERIC Educational Resources Information Center

    Stone, Jody

    2007-01-01

    With schools being asked to accomplish more and more, it is increasingly important to, whenever possible, address multiple goals in teaching. Educating the whole child dictates that we find ways to ensure our graduates are well-rounded, independent thinkers capable of becoming well-adjusted, contributing adults. Thus community service has become a…

  14. Accomplished Teachers Implementation of Quality Teaching Practices

    ERIC Educational Resources Information Center

    Chen, Weiyun; Hammond-Bennett, Austin; Upton, Ashely; Mason, Steve

    2014-01-01

    The purpose of this study was to describe how accomplished teachers implement the quality of teaching practices in their daily lessons. The participants were four elementary physical education teachers (one male, three female). The data sources consisted of videotape of the teachers teaching 12 lessons, transcription of the taped lessons,…

  15. Unraveling bovin phylogeny: accomplishments and challenges.

    PubMed

    Bibi, Faysal; Vrba, Elisabeth S

    2010-01-01

    The phylogenetic systematics of bovin species forms a common basis for studies at multiple scales, from the level of domestication in populations to major cladogenesis. The main big-picture accomplishments of this productive field, including two recent works, one in BMC Genomics, are reviewed with an eye for some of the limitations and challenges impeding progress. PMID:20525112

  16. Acoustics Division recent accomplishments and research plans

    NASA Technical Reports Server (NTRS)

    Clark, L. R.; Morgan, H. G.

    1986-01-01

    The research program currently being implemented by the Acoustics Division of NASA Langley Research Center is described. The scope, focus, and thrusts of the research are discussed and illustrated for each technical area by examples of recent technical accomplishments. Included is a list of publications for the last two calendar years. The organization, staff, and facilities are also briefly described.

  17. Biomass Program 2007 Accomplishments - Full Report

    SciTech Connect

    none,

    2009-10-27

    The Office of Energy Efficiency and Renewable Energy's (EERE’s) Biomass Program works with industry, academia and its national laboratory partners on a balanced portfolio of research in biomass feedstocks and conversion technologies. This document provides Program accomplishments for 2007.

  18. Biomass Program 2007 Accomplishments - Report Introduction

    SciTech Connect

    none,

    2009-10-27

    The Office of Energy Efficiency and Renewable Energy's (EERE’s) Biomass Program works with industry, academia and its national laboratory partners on a balanced portfolio of research in biomass feedstocks and conversion technologies. This document provides the introduction to the 2007 Program Accomplishments Report.

  19. Navajo Health Authority: Accomplishments--Future Goals.

    ERIC Educational Resources Information Center

    Navajo Health Authority, Window Rock, AZ.

    Accomplishments of the Navajo Health Authority (NHA) since it began in 1972 are presented in synopsis form in a report of programs underway at Window Rock and Shiprock, along with NHA goals: to promote development of Navajo Health manpower, preventive medicine, health education, and native healing sciences. After a brief review of executive and…

  20. Effectiveness of salt versus glass bead sterilizers.

    PubMed

    Haddad, A J; Girard, B; Bouclin, R; Valois, M; Landry, R G

    1997-06-01

    Microorganisms can be removed from dental instruments by various methods, including treatment in salt and glass bead sterilizers. However, no rigorous, controlled, in vivo or in vitro studies have been performed to verify the respective efficiencies of these methods. The goals of this study were to determine if the positioning of instruments at the centre or edge of a salt sterilizer results in differential sterilization effectiveness, and to compare the effectiveness of salt sterilizers relative to glass bead sterilizers. Autoclaved number 60 reamers were contaminated by plunging them to the handle in a commercial Bacillus stearothermophilus spore suspension. They were then sterilized for different periods of time and at different positions in the sterilizers. Each experiment included positive and negative controls. The results showed that better sterilization is achieved at the edge of the chamber than at the centre, and that salt sterilizers are more effective than glass bead sterilizers for a given period of time (15 seconds) in the sterilizer. PMID:9203778

  1. Pain Associated With Hysteroscopic Sterilization

    PubMed Central

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  2. [Sterilization: necessity or genocide?].

    PubMed

    Muraro, R M

    1991-01-01

    Recent warnings by the UN Fund for Population Activities about the rapid growth of the world population and the overwhelming role in it played by impoverished women in developing countries are of interest to all women in Latin America. According to the document, Third World Women require drastic improvements in their socioeconomic positions in order to achieve reductions in their family sizes and avoid an increase in the world population from 5 billion at present to 10 billion in 2025, which would be a disaster for the planet. The document states that much of the environmental damage that would occur would be attributable to the combination of poverty and rapid population increase. If the proportion of the world's women using contraceptives increases from the current 45% to 58% by the year 2000, the world population in 2025 will be 8.5 billion. The document recommends that the amount of money invested in family planning be greatly increased by 2000 in order to make possible increased use of family planning. It appears, however, that much of the funding for family planning is under the control of private organizations and is used to serve the interests of foreign countries. The 2 principal private family planning organizations in Brazil, for example, received 18.2 million US dollars between 1978--84, which were used largely to finance a campaign of mass sterilization. Brazil's rate of population growth, which was 2.1% in 1980-85 and 1.8% in 1990, is expected to drop to 1.6% in 1995. With the decline in the rate of growth, the population will be 170 million in 2000 instead of the 220 million projected using data from the 1970s. A much higher proportion of fertile-aged women in Brazil is sterilized than in the US or Europe . Closer examination of the premises behind family planning policies shows them to be questionable. The premise that population density affects the environment is questionable; Japan, West Germany, and Holland have some of the highest population

  3. Is a vegetarian diet adequate for children.

    PubMed

    Hackett, A; Nathan, I; Burgess, L

    1998-01-01

    The number of people who avoid eating meat is growing, especially among young people. Benefits to health from a vegetarian diet have been reported in adults but it is not clear to what extent these benefits are due to diet or to other aspects of lifestyles. In children concern has been expressed concerning the adequacy of vegetarian diets especially with regard to growth. The risks/benefits seem to be related to the degree of restriction of he diet; anaemia is probably both the main and the most serious risk but this also applies to omnivores. Vegan diets are more likely to be associated with malnutrition, especially if the diets are the result of authoritarian dogma. Overall, lacto-ovo-vegetarian children consume diets closer to recommendations than omnivores and their pre-pubertal growth is at least as good. The simplest strategy when becoming vegetarian may involve reliance on vegetarian convenience foods which are not necessarily superior in nutritional composition. The vegetarian sector of the food industry could do more to produce foods closer to recommendations. Vegetarian diets can be, but are not necessarily, adequate for children, providing vigilance is maintained, particularly to ensure variety. Identical comments apply to omnivorous diets. Three threats to the diet of children are too much reliance on convenience foods, lack of variety and lack of exercise. PMID:9670174

  4. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  5. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  6. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  7. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  8. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  9. ENSURING ADEQUATE SAFETY WHEN USING HYDROGEN AS A FUEL

    SciTech Connect

    Coutts, D

    2007-01-22

    Demonstration projects using hydrogen as a fuel are becoming very common. Often these projects rely on project-specific risk evaluations to support project safety decisions. This is necessary because regulations, codes, and standards (hereafter referred to as standards) are just being developed. This paper will review some of the approaches being used in these evolving standards, and techniques which demonstration projects can implement to bridge the gap between current requirements and stakeholder desires. Many of the evolving standards for hydrogen-fuel use performance-based language, which establishes minimum performance and safety objectives, as compared with prescriptive-based language that prescribes specific design solutions. This is being done for several reasons including: (1) concern that establishing specific design solutions too early will stifle invention, (2) sparse performance data necessary to support selection of design approaches, and (3) a risk-adverse public which is unwilling to accept losses that were incurred in developing previous prescriptive design standards. The evolving standards often contain words such as: ''The manufacturer shall implement the measures and provide the information necessary to minimize the risk of endangering a person's safety or health''. This typically implies that the manufacturer or project manager must produce and document an acceptable level of risk. If accomplished using comprehensive and systematic process the demonstration project risk assessment can ease the transition to widespread commercialization. An approach to adequately evaluate and document the safety risk will be presented.

  10. Advanced Fuels Campaign FY 2011 Accomplishments Report

    SciTech Connect

    Not Listed

    2011-11-01

    One of the major research and development (R&D) areas under the Fuel Cycle Research and Development (FCRD) program is advanced fuels development. The Advanced Fuels Campaign (AFC) has the responsibility to develop advanced fuel technologies for the Department of Energy (DOE) using a science-based approach focusing on developing a microstructural understanding of nuclear fuels and materials. Accomplishments made during fiscal year (FY 20) 2011 are highlighted in this report, which focuses on completed work and results. The process details leading up to the results are not included; however, the technical contact is provided for each section. The order of the accomplishments in this report is consistent with the AFC work breakdown structure (WBS).

  11. [Sterilization of mentally retarded women].

    PubMed

    Heidenreich, W; Petersen, P; Schneider, J

    1982-07-01

    Seven mentally retarded women were sterilized in the Department of Obstetrics and Gynaecology of Medical School Hannover between 1.6.74 and 1.6.81. The decision to operate proceeded only after careful consideration by the director of the clinic. Each case was documented with proof that improvement of the mental situation was unprobable and that sterilization seemed highly desirable. In spite of strong reservation the sterilization of a mentally retarded may medically and ethically be justified in exceptional cases. The operation seems possible by the following: The sterilization may only be performed if the patient does not obviously refuse it. Diagnosis and prognosis of the mental handicap must undoubtedly be proven. If the patient cannot judge the consequence of the operation the legal guardian must decide for her. The court must consent in these cases. Regarding legal theory the decision by the guardian is an open question. PMID:6922080

  12. Sterilization surgery - making a decision

    MedlinePlus

    ... can sometimes be reversed, both must be considered permanent forms of birth control. When deciding if you want to have a ... other options for preventing pregnancy that are not permanent. Talk ... before making the decision to have a sterilization procedure.

  13. Joint Winter Runway Friction Program Accomplishments

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.; Wambold, James C.; Henry, John J.; Andresen, Arild; Bastian, Matthew

    2002-01-01

    The major program objectives are: (1) harmonize ground vehicle friction measurements to report consistent friction value or index for similar contaminated runway conditions, for example, compacted snow, and (2) establish reliable correlation between ground vehicle friction measurements and aircraft braking performance. Accomplishing these objectives would give airport operators better procedures for evaluating runway friction and maintaining acceptable operating conditions, providing pilots information to base go/no go decisions, and would contribute to reducing traction-related aircraft accidents.

  14. NASA total quality management 1989 accomplishments report

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Described here are the accomplishments of NASA as a result of the use of Total Quality Management (TQM). The principles in practice which led to these process refinements are important cultural elements to any organization's productivity and quality efforts. The categories of TQM discussed here are top management leadership and support, strategic planning, focus on the customer, employee training and recognition, employee empowerment and teamwork, measurement and analysis, and quality assurance.

  15. Enhanced surveillance program FY1998 accomplishments

    SciTech Connect

    Kass, J

    1998-10-01

    This report highlights the accomplishments of the Enhanced Surveillance Program (ESP), the highest-priority research and development effort in stockpile management today. This is volume one of eleven, the unclassified summary of selected program highlights. These highlights fall into the following focus areas: pits, high explosives, organics, dynamics, diagnostics, systems, secondaries, materials-aging models, non-nuclear components, and routine surveillance testing system upgrades. Principal investigators from around the DOE complex contributed to this report.

  16. NASA total quality management 1990 accomplishments report

    NASA Technical Reports Server (NTRS)

    1991-01-01

    NASA's efforts in Total Quality Management are based on continuous improvement and serve as a foundation for NASA's present and future endeavors. Given here are numerous examples of quality strategies that have proven effective and efficient in a time when cost reduction is critical. These accomplishment benefit our Agency and help to achieve our primary goal, keeping American in the forefront of the aerospace industry.

  17. Unraveling bovin phylogeny: accomplishments and challenges

    PubMed Central

    2010-01-01

    The phylogenetic systematics of bovin species forms a common basis for studies at multiple scales, from the level of domestication in populations to major cladogenesis. The main big-picture accomplishments of this productive field, including two recent works, one in BMC Genomics, are reviewed with an eye for some of the limitations and challenges impeding progress. See Research article http://www.biomedcentral.com/1471-2164/10/177 PMID:20525112

  18. FY005 Accomplishments for Colony Project

    SciTech Connect

    Jones, T; Kale, L; Moreira, J; Mendes, C; Chakravorty, S; Inglett, T; Tauferner, A

    2005-07-05

    The Colony Project is developing operating system and runtime system technology to enable efficient general purpose environments on tens of thousands of processors. To accomplish this, we are investigating memory management techniques, fault management strategies, and parallel resource management schemes. Recent results show promising findings for scalable strategies based on processor virtualization, in-memory checkpointing, and parallel aware modifications to full featured operating systems.

  19. Significant Accomplishments in Science and Technology

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The proceedings of a symposium on significant accomplishments in science and technology are presented. The symposium was held at the Goddard Space Flight Center in December 1973. The subjects discussed are as follows: (1) cometary physics, (2) X-ray and gamma ray astronomy, (3) solar and terrestrial physics, (4) spacecraft technology, (5) Earth Resources Technology Satellite, (6) earth and ocean physics, (6) communications and navigation, (7) mission operations and data systems, and (8) networks systems and operations.

  20. Food irradiation and sterilization

    NASA Astrophysics Data System (ADS)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  1. Dog and cat management through sterilization: Implications for population dynamics and veterinary public policies.

    PubMed

    Dias, Ricardo Augusto; Baquero, Oswaldo Santos; Guilloux, Aline Gil Alves; Moretti, Caio Figueiredo; de Lucca, Tosca; Rodrigues, Ricardo Conde Alves; Castagna, Cláudio Luiz; Presotto, Douglas; Kronitzky, Yury Cezar; Grisi-Filho, José Henrique Hildebrand; Ferreira, Fernando; Amaku, Marcos

    2015-11-01

    The present study aimed to compare different sterilization scenarios allowing the adoption of the most adequate strategy to control owned dog and cat population sizes as the official veterinary public policy for animal control in an urban area of Campinas municipality, Brazil. To achieve this goal, the vital parameters of the owned pet population were measured in a neighborhood of Campinas called Jardim Vila Olimpia through questionnaires used in two census studies performed in February 2012 and June 2013. Different hypothetical sterilization scenarios were compared with the scenario of a single sterilization campaign performed in the study area between the census studies. Using a deterministic mathematical model, population dynamics were simulated for these different scenarios. We have observed that for both owned dogs and cats, the impact on the population size achieved by a single sterilization campaign would be diluted over the years, equating to the impact achieved by the usual sterilization rate practiced before the sterilization campaign yearly. Moreover, using local and global sensitivity analyses, we assessed the relative influence on animal population evolution of each vital parameter used in the mathematical models. The more influential parameters for both species were the carrying capacity of the environment and sterilization rates of males and females (for both species). We observed that even with sterilizing 100% of the intact animals annually, it would not be possible to obtain proportions greater than 86% and 88% of sterilized dogs and cats, respectively, after 20 years due to the high introduction of new intact animals. There is no public dog and cat sterilization service in place in the city, and sporadic and local sterilization campaigns are performed with a prior communication to the owners to bring their animals to be sterilized in a selected veterinary facility. If a sterilization campaign was performed annually in the study area, it would

  2. Voluntary sterilization in North Tyneside.

    PubMed

    Carnegie-Smith, K

    1984-04-01

    Since 1975, sterilization operations, on both men and women have been performed with increasing frequency within the National Health Service in the North Tyneside Area in northeast England. A prospective study was undertaken to discover some of the reasons why healthy young men and women chose surgical sterilization rather than use the established reversible methods of family planning available to them. The study examined some of the characteristics of those requesting sterilization, attempted to understand why they did so at that particular time, and assessed the patient-perceived morbidity resulting from this elective procedure. The study population included all individuals referred for consultation following the patient's request for voluntary sterilization by vasectomy or occlusive tubal surgery, during the period of 1 year (August 1, 1980-July 31, 1981). Women sterilized in association with a pregnancy outcome were not included in the study. Data on pregnancies and sterilizations in North Tyneside demonstrate a rapid increase in requests for vasectomy after 1975. Patients requesting sterilization were admitted to the study during the initial out-patient appointment with their surgeon. Couples seeking sterilization show similar age range for men (mean 34.2) and women (33.1). The proportion of patients who were not married at the time of the operation is perhaps a reflection of doctors' increasing willingness to perform sterilizations on the unmarried, and of individuals to seek such surgery in a committed manner. The increasing tendency for requests to be received from people still in their early 20s is seen as a problem. Data indicates that married people who request the operation at an early age are also those who were married under age 21, started a family immediately and with a 25% divorce rate. At the other end of the age range, couples who ahve been sucessfully using oral contraceptives have become concerned about its safety, especially after age 35. Data

  3. Basic Energy Sciences: Summary of Accomplishments

    DOE R&D Accomplishments Database

    1990-05-01

    For more than four decades, the Department of Energy, including its predecessor agencies, has supported a program of basic research in nuclear- and energy-related sciences, known as Basic Energy Sciences. The purpose of the program is to explore fundamental phenomena, create scientific knowledge, and provide unique user'' facilities necessary for conducting basic research. Its technical interests span the range of scientific disciplines: physical and biological sciences, geological sciences, engineering, mathematics, and computer sciences. Its products and facilities are essential to technology development in many of the more applied areas of the Department's energy, science, and national defense missions. The accomplishments of Basic Energy Sciences research are numerous and significant. Not only have they contributed to Departmental missions, but have aided significantly the development of technologies which now serve modern society daily in business, industry, science, and medicine. In a series of stories, this report highlights 22 accomplishments, selected because of their particularly noteworthy contributions to modern society. A full accounting of all the accomplishments would be voluminous. Detailed documentation of the research results can be found in many thousands of articles published in peer-reviewed technical literature.

  4. Basic energy sciences: Summary of accomplishments

    NASA Astrophysics Data System (ADS)

    1990-05-01

    For more than four decades, the Department of Energy, including its predecessor agencies, has supported a program of basic research in nuclear- and energy related sciences, known as Basic Energy Sciences. The purpose of the program is to explore fundamental phenomena, create scientific knowledge, and provide unique user facilities necessary for conducting basic research. Its technical interests span the range of scientific disciplines: physical and biological sciences, geological sciences, engineering, mathematics, and computer sciences. Its products and facilities are essential to technology development in many of the more applied areas of the Department's energy, science, and national defense missions. The accomplishments of Basic Energy Sciences research are numerous and significant. Not only have they contributed to Departmental missions, but have aided significantly the development of technologies which now serve modern society daily in business, industry, science, and medicine. In a series of stories, this report highlights 22 accomplishments, selected because of their particularly noteworthy contributions to modern society. A full accounting of all the accomplishments would be voluminous. Detailed documentation of the research results can be found in many thousands of articles published in peer-reviewed technical literature.

  5. Radiation sterilization of skin allograft

    NASA Astrophysics Data System (ADS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  6. Neutrino Oscillations With Two Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Kisslinger, Leonard S.

    2016-06-01

    This work estimates the probability of μ to e neutrino oscillation with two sterile neutrinos using a 5×5 U-matrix, an extension of the previous estimate with one sterile neutrino and a 4×4 U-matrix. The sterile neutrino-active neutrino mass differences and the mixing angles of the two sterile neutrinos with the three active neutrinos are taken from recent publications, and the oscillation probability for one sterile neutrino is compared to the previous estimate.

  7. Sandia technology engineering and science accomplishments

    SciTech Connect

    Not Available

    1993-03-01

    Sandia is a DOE multiprogram engineering and science laboratory with major facilities at Albuquerque, New Mexico, and Livermore, California, and a test range near Tonapah, Nevada. We have major research and development responsibilities for nuclear weapons, arms control, energy, the environment, economic competitiveness, and other areas of importance to the needs of the nation. Our principal mission is to support national defense policies by ensuring that the nuclear weapon stockpile meets the highest standards of safety, reliability, security, use control, and military performance. Selected unclassified technical activities and accomplishments are reported here. Topics include advanced manufacturing technologies, intelligent machines, computational simulation, sensors and instrumentation, information management, energy and environment, and weapons technology.

  8. Advanced Fuels Campaign FY 2015 Accomplishments Report

    SciTech Connect

    Braase, Lori Ann; Carmack, William Jonathan

    2015-10-29

    The mission of the Advanced Fuels Campaign (AFC) is to perform research, development, and demonstration (RD&D) activities for advanced fuel forms (including cladding) to enhance the performance and safety of the nation’s current and future reactors; enhance proliferation resistance of nuclear fuel; effectively utilize nuclear energy resources; and address the longer-term waste management challenges. This report is a compilation of technical accomplishment summaries for FY-15. Emphasis is on advanced accident-tolerant LWR fuel systems, advanced transmutation fuels technologies, and capability development.

  9. Genomic Networks of Hybrid Sterility

    PubMed Central

    Turner, Leslie M.; White, Michael A.; Tautz, Diethard; Payseur, Bret A.

    2014-01-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci (“Dobzhansky-Muller incompatibilities”). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven ‘hotspots,’ seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL—but not cis eQTL—were substantially lower when mapping was restricted to a ‘fertile’ subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  10. Heat Sterilization of Water in a Large Open Vessel

    PubMed Central

    Yale, Charles E.; Linsley, James G.; Anderson, Lawrence C.

    1968-01-01

    A safe, convenient, and economical method of preparing and dispensing a large volume of sterile water in a movable container is described. A caster-mounted, rectangular, 100-gal, stainless-steel water tank was fabricated. An audible, solid-state water-level alarm was developed for use with a detachable sensing probe that could be autoclaved. A filter system was constructed to allow the tank to be autoclaved as an open vessel. Thermocouples were mounted within the tank of water to study the time-temperature relationships of the water during the sterilization cycle. In a downward displacement autoclave with a hot jacket, 75 min were required for the water temperature to rise from 140 to 240 F (60 to 116 C). A total of 3 hr for heating and holding includes an adequate safety factor to insure the sterility of the water immediately after autoclaving. The long-term sterility of the water and the safety of the system were verified by using the water to maintain a germ-free animal colony. Images Fig. 1 Fig. 2 PMID:5647520

  11. Advanced Fuels Campaign FY 2010 Accomplishments Report

    SciTech Connect

    Lori Braase

    2010-12-01

    The Fuel Cycle Research and Development (FCRD) Advanced Fuels Campaign (AFC) Accomplishment Report documents the high-level research and development results achieved in fiscal year 2010. The AFC program has been given responsibility to develop advanced fuel technologies for the Department of Energy (DOE) using a science-based approach focusing on developing a microstructural understanding of nuclear fuels and materials. The science-based approach combines theory, experiments, and multi-scale modeling and simulation aimed at a fundamental understanding of the fuel fabrication processes and fuel and clad performance under irradiation. The scope of the AFC includes evaluation and development of multiple fuel forms to support the three fuel cycle options described in the Sustainable Fuel Cycle Implementation Plan4: Once-Through Cycle, Modified-Open Cycle, and Continuous Recycle. The word “fuel” is used generically to include fuels, targets, and their associated cladding materials. This document includes a brief overview of the management and integration activities; but is primarily focused on the technical accomplishments for FY-10. Each technical section provides a high level overview of the activity, results, technical points of contact, and applicable references.

  12. Bacterial Sterilization Using Cavitating Jet

    NASA Astrophysics Data System (ADS)

    Azuma, Yohei; Kato, Hiroharu; Usami, Ron; Fukushima, Tadamasa

    In this paper, a new sterilization method using cavitating flow is presented. Water with bacteria was pressurized up to 105 MPa and flushed out through two very small nozzles 0.1-0.31 mm in diameter, where a cavitating jet was generated containing bubbles that collapsed downstream. First, the effects of jet velocity and cavitation number on the sterilization rate of Escherichia coli JCM1649T (E. coli) were examined. The sterilization rate increased with jet velocity. The rate was proportional to the 3rd power of the velocity. All the E. coli cells were killed by three successive treatments at V=355.7 m/s and cavitation number σ=0.154. The sterilization rate has a peak depending on cavitation number at the low-jet-velocity region of less than 300 m/s. An experiment was also performed to compare two types of bacteria, E. coli, as typical Gram-negative bacteria and Bacillus subtilis JCM1465T (B. subtilis), as typical Gram-positive bacteria. Additional tests were performed using Pseudomonas putida JCM13063T, Gram-negative bacteria and Bacillus halodurans JCTM9153, Gram-positive bacteria. The sterilization rate of the Gram-positive bacteria was much lower than that of the Gram-negative bacteria under the same experimental conditions. Gram-positive bacteria have a thicker peptidoglycan layer than Gram-negative bacteria. This may be the reason why B. subtilis is more resistant to the mechanical stress caused by cavitating flow.

  13. [Psychosexual implications of female sterilization].

    PubMed

    Grio, R; Fusi, D; Corsello, F P; Canestrelli, M; Abbondanza, M; Arrichiello, G; Marchino, G L

    1991-12-01

    According to data of the Italian Association for Demographic Education, from 1978 to 1991 a total of 16,000 sterilizations were carried out in patients with an average age of 36 years. There was an increasing frequency of anxiety, depression, and lack of satisfaction with sexual life, and deterioration of marital life as the consequence of the operations. Psychological improvement has been reported in only a few cases. Hysterectomy, mastectomy, abortion, and sterilization produce profound psychological effects in women. The ideal candidate for such intervention should be fully aware of the choice and be well informed about the reproductive system, and aged over 30 with at least 2 children in a stable marital relationship. A 1973 review of 80 different studies carried out in 12 different countries reported that 82% of women benefited from the operation. In a study of 180 patients in Glasgow, Scotland, psychosexual disorders were found, in only 3.6%. In a 1975 report, postoperative psychiatric disturbances in sexual life were recorded in 2% of 98 women. Another study of 94 women who were sterilized did not find any medical or psychological problems but did find patients who were completely satisfied 2 years later. In a study of 50 patients who underwent surgical sterilization by the Pomeroy technique during cesarean section, sexual behavior in the women, measured as desire, frequency of intercourse, and satisfaction, was unchanged in 47, while in 3 there were only modest variations in libido and frequency of intercourse. On the basis of these reports in the majority of cases the outcome of sterilization was favorable when assessing various gynecological problems over time. On the other hand, when the candidate is a young woman the information has to be particularly detailed and scrupulous with respect to risks and the probable irreversibility of sterilization. PMID:1819775

  14. Health and Environmental Research. Summary of Accomplishments

    DOE R&D Accomplishments Database

    1984-04-01

    This is a short account of a 40-year-old health and environmental research program performed in national laboratories, universities, and research institutes. Under the sponsorship of the federal agencies that were consecutively responsible for the national energy mission, this research program has contributed to the understanding of the human health and environmental effects of emergining energy technologies. In so doing, it has also evolved several nuclear techniques for the diagnosis and treatment of human ills. The form of this presentation is through examples of significant, tangible accomplishments in each of these areas at certain times to illustrate the role and impact of the research program. The narrative of this research program concludes with a perspective of its past and a prospectus on its future.

  15. Low Cost Methods to Accomplish Aeronomy Science

    NASA Astrophysics Data System (ADS)

    Swenson, G. R.

    2013-12-01

    Accomplishment of aeronomy science using low cost methods involves a number of innovative considerations. These methods will be discussed. They include making broad use of internet to control and operate distributed sensors. Sensor controls should be simple and most important reliable. Imagers are a common sensor for optical systems and include common computer interfaces and menu driven operations which often don't require special software or engineering development. Small, inexpensive but reliable satellite systems are evolving in the Cubesat community. Effective use of students is invaluable, giving them responsibility to operate instrumentation and to routinely archive the data. Management of students is especially important in the early phase of their training to insure quality performance. These ideas will be elaborated on, and most importantly, the science motive is the most important driver for what is done.

  16. NASA total quality management 1989 accomplishments report

    NASA Technical Reports Server (NTRS)

    Tai, Betty P. (Editor); Stewart, Lynne M. (Editor)

    1990-01-01

    NASA and contractor employees achieved many notable improvements in 1989. The highlights of those improvements, described in this seventh annual Accomplishments Report, demonstrate that the people who support NASA's activities are getting more involved in quality and continuous improvement efforts. Their gains solidly support NASA's and this Nation's goal to remain a leader in space exploration and in world-wide market competition, and, when communicated to others through avenues such as this report, foster improvement efforts across government and industry. The principles in practice which led to these process refinements are important cultural elements to any organization's productivity and quality efforts. The categories in this report reflect NASA principles set forth in the 1980's and are more commonly known today as Total Quality Management (TQM): top management leadership and support; strategic planning; focus on the customer; employee training and recognition; employee empowerment and teamwork; measurement and analysis; and quality assurance.

  17. Health and environmental research. Summary of accomplishments

    SciTech Connect

    Not Available

    1984-04-01

    This is a short account of a 40-year-old health and environmental research program performed in national laboratories, universities, and research institutes. Under the sponsorship of the federal agencies that were consecutively responsible for the national energy mission, this research program has contributed to the understanding of the human health and environmental effects of emergining energy technologies. In so doing, it has also evolved several nuclear techniques for the diagnosis and treatment of human ills. The form of this presentation is through examples of significant, tangible accomplishments in each of these areas at certain times to illustrate the role and impact of the research program. The narrative of this research program concludes with a perspective of its past and a prospectus on its future.

  18. High Speed Research: Propulsion Project Accomplishments

    NASA Technical Reports Server (NTRS)

    Shaw, Robert J.

    1998-01-01

    This past year has been one of great accomplishment for the propulsion element of NASA's High Speed Research (HSR) Program. The HSR Program is a NASA/industry partnership to develop the high-risk/high-payoff airframe and propulsion technologies applicable to a second-generation supersonic commercial transport, or High Speed Civil Transport (HSCT). The propulsion element, which also involves industry partners, is managed by the NASA Lewis Research Center. These technologies will contribute greatly to U.S. industry's ability to make an informed product launch decision for an HSCT vehicle. Specific NASA Lewis accomplishments in 1997 include: 1. Small-scale combustor sector tests conducted in Lewis' Engine Research Building contributed to the evolution of approaches to developing a combustor with ultralow NOx emissions. 2. Components were tested in Lewis' CE-9 facility (in Lewis' Engine Research Building) to assess the performance of candidate ceramic matrix composite (CMC) materials in this realistic combustion environment. Test results were promising, and acceptable levels of structural durability were demonstrated for the ceramic matrix composite material tested. Ceramic matrix composites continue to show great promise for use in HSCT combustor liners. 3. Engine emissions tests in Lewis' Propulsion Systems Laboratory provided insight into other classes of emissions (e.g., particulates and aerosols) which will be important to control in HSCT propulsion system designs. 4. Small-scale nozzle tests conducted in Lewis' Aero-Acoustic Propulsion Laboratory are contributing to the design of a low-noise, high-performance mixer/ejector nozzle configuration for HSCT engines. Over 18,000 hours of durability testing were completed in Lewis' materials laboratories to evaluate superalloy and g-titanium aluminide performance for HSCT nozzle applications. A two-dimensional supersonic inlet concept was tested in Lewis' 10- by 10-Foot Supersonic Wind Tunnel. The extensive database and

  19. CEMENTITIOUS BARRIERS PARTNERSHIP ACCOMPLISHMENTS AND RELEVANCE TO THE DOE COMPLEX

    SciTech Connect

    Burns, H.; Langton, C.; Flach, G.; Kosson, D.

    2010-11-15

    The Cementitious Barriers Partnership (CBP) was initiated to reduce risk and uncertainties in the performance assessments that directly impact U.S. Department of Energy (DOE) environmental cleanup and closure programs. The CBP is supported by the DOE Office of Environmental Management (DOE-EM) and has been specifically addressing the following critical EM program needs: (i) the long-term performance of cementitious barriers and materials in nuclear waste disposal facilities and (ii) increased understanding of contaminant transport behavior within cementitious barrier systems to support the development and deployment of adequate closure technologies. To accomplish this, the CBP has two initiatives: (1) an experimental initiative to increase understanding of changes in cementitious materials over long times (> 1000 years) over changing conditions and (2) a modeling initiative to enhance and integrate a set of computational tools validated by laboratory and field experimental data to improve understanding and prediction of the long-term performance of cementitious barriers and waste forms used in nuclear applications. In FY10, the CBP developed the initial phase of an integrated modeling tool that would serve as a screening tool which could help in making decisions concerning disposal and tank closure. The CBP experimental programs are underway to validate this tool and provide increased understanding of how CM changes over time and under changing conditions. These initial CBP products that will eventually be enhanced are anticipated to reduce the uncertainties of current methodologies for assessing cementitious barrier performance and increase the consistency and transparency of the DOE assessment process. These tools have application to low activity waste forms, high level waste tank closure, D&D and entombment of major nuclear facilities, landfill waste acceptance criteria, and in-situ grouting and immobilization of vadose zone contamination. This paper summarizes

  20. What can Recycling in Thermal Reactors Accomplish?

    SciTech Connect

    Steven Piet; Gretchen E. Matthern; Jacob J. Jacobson

    2007-09-01

    Thermal recycle provides several potential benefits when used as stop-gap, mixed, or backup recycling to recycling in fast reactors. These three roles involve a mixture of thermal and fast recycling; fast reactors are required to some degree at some time. Stop-gap uses thermal reactors only until fast reactors are adequately deployed and until any thermal-recycle-only facilities have met their economic lifetime. Mixed uses thermal and fast reactors symbiotically for an extended period of time. Backup uses thermal reactors only if problems later develop in the fast reactor portion of a recycling system. Thermal recycle can also provide benefits when used as pure thermal recycling, with no intention to use fast reactors. However, long term, the pure thermal recycling approach is inadequate to meet several objectives.

  1. Sterilization of Persons with Mental Retardation.

    ERIC Educational Resources Information Center

    Elkins, Thomas E.; Andersen, H. Frank

    1992-01-01

    This article examines the historical, legal, and ethical concerns regarding sterilization for persons with mental retardation and offers guidelines to help counsel individuals with disabilities or their families regarding decision making about sterilization. (DB)

  2. Sterilization beneath rings on dental instruments.

    PubMed

    Miller, C H; Sheldrake, M A

    1991-12-01

    This study determined the effectiveness of standard methods of instrument sterilization beneath instrument rings. Sets of three types of dental instruments were contaminated with known amounts of bacterial spores (Bacillus stearothermophilus or Bacillus subtilis). Instrument rings were placed over the contamination and the instruments processed through standard cycles in a steam autoclave, an unsaturated chemical vapor sterilizer, a standard dry heat sterilizer, an ethylene oxide gas sterilizer or a 2.0% alkaline glutaraldehyde solution. Controls consisted of spore-contaminated instruments without rings that were not processed through any sterilizing method and that were processed through each sterilizing method. All instruments and their associated rings were cultured for the presence of live spores. The results indicate that the reliability of sterilization beneath the instrument rings used is greatest if the ringed instruments are processed through a steam autoclave or an unsaturated chemical vapor sterilizer. PMID:1814351

  3. Low Temperature Atmospheric Pressure Plasma Sterilization Shower

    NASA Astrophysics Data System (ADS)

    Gandhiraman, R. P.; Beeler, D.; Meyyappan, M.; Khare, B. N.

    2012-10-01

    Low-temperature atmospheric pressure plasma sterilization shower to address both forward and backward biological contamination issues is presented. The molecular effects of plasma exposure required to sterilize microorganisms is also analysed.

  4. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42...

  5. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42...

  6. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR part 441, subpart F, except that the State plan requirement under 42...

  7. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42...

  8. 21 CFR 201.5 - Drugs; adequate directions for use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Drugs; adequate directions for use. 201.5 Section...) DRUGS: GENERAL LABELING General Labeling Provisions § 201.5 Drugs; adequate directions for use. Adequate directions for use means directions under which the layman can use a drug safely and for the purposes...

  9. 21 CFR 201.5 - Drugs; adequate directions for use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Drugs; adequate directions for use. 201.5 Section...) DRUGS: GENERAL LABELING General Labeling Provisions § 201.5 Drugs; adequate directions for use. Adequate directions for use means directions under which the layman can use a drug safely and for the purposes...

  10. 4 CFR 200.14 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 4 Accounts 1 2010-01-01 2010-01-01 false Responsibility for maintaining adequate safeguards. 200.14 Section 200.14 Accounts RECOVERY ACCOUNTABILITY AND TRANSPARENCY BOARD PRIVACY ACT OF 1974 § 200.14 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining adequate technical, physical, and...

  11. 10 CFR 1304.114 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Responsibility for maintaining adequate safeguards. 1304.114 Section 1304.114 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.114 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining adequate technical, physical, and security...

  12. 10 CFR 1304.114 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Responsibility for maintaining adequate safeguards. 1304.114 Section 1304.114 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.114 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining adequate technical, physical, and security...

  13. 4 CFR 200.14 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 4 Accounts 1 2011-01-01 2011-01-01 false Responsibility for maintaining adequate safeguards. 200....14 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining adequate technical, physical, and security safeguards to prevent unauthorized disclosure...

  14. Plasma Sterilization Technology for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Fraser, S. J.; Olson, R. L.; Leavens, W. M.

    1975-01-01

    The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

  15. Microwave powered sterile access port

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Atwater, James E. (Inventor); Dahl, Roger W. (Inventor); Garmon, Frank C. (Inventor); Lunsford, Teddie D. (Inventor); Michalek, William F. (Inventor); Wheeler, Jr., Richard R. (Inventor)

    2000-01-01

    A device and method for elimination of contamination during transfer of materials either into or from bioreactors, food containers, or other microbially vulnerable systems. Using microwave power, thermal sterilizations of mating fixtures are achieved simply, reliably, and quickly by the volatilization of small quantities of water to produce superheated steam which contacts all exposed surfaces.

  16. Sterile Neutrino Search with MINOS

    SciTech Connect

    Devan, Alena V.

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  17. Sterile Neutrino Search with MINOS

    NASA Astrophysics Data System (ADS)

    Devan, Alena V.

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Amt. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, Delta m2s 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  18. Sterile pyuria: a forgotten entity

    PubMed Central

    Persad, Raj

    2015-01-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results. PMID:26425144

  19. The limits of sterility assurance

    PubMed Central

    von Woedtke, Thomas; Kramer, Axel

    2008-01-01

    Sterility means the absence of all viable microorganisms including viruses. At present, a sterility assurance level (SAL) of 10–6 is generally accepted for pharmacopoeial sterilization procedures, i.e., a probability of not more than one viable microorganism in an amount of one million sterilised items of the final product. By extrapolating the reduction rates following extreme artificial initial contamination, a theoretical overall performance of the procedure of at least 12 lg increments (overkill conditions) is demanded to verify an SAL of 10–6. By comparison, other recommendations for thermal sterilization procedures demand only evidence that the difference between the initial contamination and the number of test organisms at the end of the process amount to more than six orders of magnitude. However, a practical proof of the required level of sterility assurance of 10–6 is not possible. Moreover, the attainability of this condition is fundamentally dubious, at least in non-thermal procedures. Thus, the question is discussed whether the undifferentiated adherence to the concept of sterility assurance on the basis of a single SAL of 10–6 corresponds with the safety requirements in terms of patient or user safety, costs and energy efficiency. Therefore, in terms of practical considerations, a concept of tiered SALs is recommended, analogous to the comparable and well-established categorization into “High-level disinfection”, “Intermediate-level disinfection” and “Low-level disinfection”. The determination of such tiered SALs is geared both to the intended application of the sterilized goods, as well as to the characteristics of the products and the corresponding treatment options. In the case of aseptic preparation, filling and production procedures, a mean contamination probability of 10–3 is assumed. In automated processes, lower contamination rates can be realized. In the case of the production of re-usable medical devices, a reduction of

  20. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42 CFR... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public...

  1. Microwave Sterilization and Depyrogenation System

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  2. Bisexual Hybrid Sterility in DROSOPHILA MELANOGASTER

    PubMed Central

    Colgan, D. J.; Angus, D. S.

    1978-01-01

    A new type of hybrid sterility was investigated in D. melanogaster . Matings between strain 27 males from Para Wirra, South Australia, and Canton-S females produce 70–80% fully sterile male and female progeny. Strain 27 males produce sterile progeny when crossed to females of other geographic origins, but produce fertile progeny when crossed to a second sympatric strain. The sterility is avoided by lower rearing temperatures. Heat shock and tetracycline produce no improvement in the fertility of the hybrids. Normal flies produce sterile progeny when injected with, or fed, homogenates of sterile flies. A combination of maternal and paternal factors may interact to produce sterile hybrids by inhibiting gonad development. PMID:17248832

  3. Sixteen years of experience with sterilization monitoring.

    PubMed

    Molinari, J A; Gleason, M J; Merchant, V A

    1994-12-01

    Sterilization in the dental office should be monitored to ascertain proper sterilizer function. Biologic monitoring with calibrated preparations of bacterial spores is the preferred, as well as the only method that actually measures sterilization. A dental school-based sterilization monitoring service for dental practices was established in 1978 at the University of Detroit. This service has grown from 20 participating dental offices to more than 1,500. In 1993, 18,137 biologic monitoring tests were performed. The participants in the service primarily use autoclaves (70%) for heat sterilization, while unsaturated chemical-vapor sterilizers (20%) and dry-heat units (10%) are less common. This article describes the history of sterilization monitoring in dental practices from 1978 to the present through a dental school-based service. PMID:7758029

  4. Implementing AORN recommended practices for sterilization.

    PubMed

    Graybill-D'Ercole, Patricia

    2013-05-01

    Any hospital or facility in which surgery and other invasive procedures are performed should have accommodations for cleaning, decontaminating, disinfecting, and sterilizing instruments, equipment, and other essential supplies that are used for patient procedures. Sterilization is essential to reducing or preventing the risk of surgical site infections. This is a collaborative process and should include all health care providers who handle these instruments, including perioperative nurses. The revised AORN "Recommended practices for sterilization," which became effective June 15, 2012, includes updates on sterilizing single-use items, inspecting critical items before sterilization, using low-temperature hydrogen peroxide vapor sterilization methods, and immediate use steam sterilization. This RP document is the first AORN document to be evidence rated and accepted for inclusion in the Agency for Healthcare Research and Quality National Guideline Clearinghouse. PMID:23622825

  5. Lunabotics Mining Competition: Inspiration Through Accomplishment

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.

    2011-01-01

    NASA's Lunabotics Mining Competition is designed to promote the development of interest in space activities and STEM (Science, Technology, Engineering, and Mathematics) fields. The competition uses excavation, a necessary first step towards extracting resources from the regolith and building bases on the moon. The unique physical properties of lunar regolith and the reduced 1/6th gravity, vacuum environment make excavation a difficult technical challenge. Advances in lunar regolith mining have the potential to significantly contribute to our nation's space vision and NASA space exploration operations. The competition is conducted annually by NASA at the Kennedy Space Center Visitor Complex. The teams that can use telerobotic or autonomous operation to excavate a lunar regolith geotechnical simulant, herein after referred to as Black Point-1 (or BP-1) and score the most points (calculated as an average of two separate 10-minute timed competition attempts) will eam points towards the Joe Kosmo Award for Excellence and the scores will reflect ranking in the on-site mining category of the competition. The minimum excavation requirement is 10.0 kg during each competition attempt and the robotic excavator, referred to as the "Lunabot", must meet all specifications. This paper will review the achievements of the Lunabotics Mining Competition in 2010 and 2011, and present the new rules for 2012. By providing a framework for robotic design and fabrication, which culminates in a live competition event, university students have been able to produce sophisticated lunabots which are tele-operated. Multi-disciplinary teams are encouraged and the extreme sense of accomplishment provides a unique source of inspiration to the participating students, which has been shown to translate into increased interest in STEM careers. Our industrial sponsors (Caterpillar, Newmont Mining, Harris, Honeybee Robotics) have all stated that there is a strong need for skills in the workforce related

  6. Light Water Reactor Sustainability Accomplishments Report

    SciTech Connect

    McCarthy, Kathryn A.

    2015-02-01

    Welcome to the 2014 Light Water Reactor Sustainability (LWRS) Program Accomplishments Report, covering research and development highlights from 2014. The LWRS Program is a U.S. Department of Energy research and development program to inform and support the long-term operation of our nation’s commercial nuclear power plants. The research uses the unique facilities and capabilities at the Department of Energy national laboratories in collaboration with industry, academia, and international partners. Extending the operating lifetimes of current plants is essential to supporting our nation’s base load energy infrastructure, as well as reaching the Administration’s goal of reducing greenhouse gas emissions to 80% below 1990 levels by the year 2050. The purpose of the LWRS Program is to provide technical results for plant owners to make informed decisions on long-term operation and subsequent license renewal, reducing the uncertainty, and therefore the risk, associated with those decisions. In January 2013, 104 nuclear power plants operated in 31 states. However, since then, five plants have been shut down (several due to economic reasons), with additional shutdowns under consideration. The LWRS Program aims to minimize the number of plants that are shut down, with R&D that supports long-term operation both directly (via data that is needed for subsequent license renewal), as well indirectly (with models and technology that provide economic benefits). The LWRS Program continues to work closely with the Electric Power Research Institute (EPRI) to ensure that the body of information needed to support SLR decisions and actions is available in a timely manner. This report covers selected highlights from the three research pathways in the LWRS Program: Materials Aging and Degradation, Risk-Informed Safety Margin Characterization, and Advanced Instrumentation, Information, and Control Systems Technologies, as well as a look-ahead at planned activities for 2015. If you

  7. Some History and Accomplishments of the IUSS

    NASA Astrophysics Data System (ADS)

    Brevik, Eric C.; Hartemink, Alfred E.

    2013-04-01

    Urban Soils) and three standing committees (Committee on awards and prizes, Committee on budget and finances, and Committee on statutes and byelaws). Membership in ISSS/IUSS increased from around 550 after WWII to over 60,000 today. The IUSS also provides Honorary Membership to soil scientists who have significant accomplishments in the field; to date 87 soil scientists have been so recognized from all over the globe. The IUSS is the most important global link to the world's leading soil science and soil scientists.

  8. [Prolactin and sterility (author's transl)].

    PubMed

    Santeler, P; Martin, J; Daxenbichler, G

    1980-07-01

    From July 1975 to December 1979 at the Univ.-Klinik für Frauenheilkunde, Innsbruck, 91 female sterile patients were examined due to hyperprolactinaemia. Since hyperprolactin presents common symptoms of different diseases, we established a differentiated clarification and therapy scheme using the guidelines of the W.H.O. and all new knowledge. After disqualification of patients with corresponding tubular sterility, we induced in 24 patients 32 pregnancies with medication or operative therapy. After birth or abortion a prolactin-caused dysfunction reappeared in the reproductive system. With a gradual prolactin increasion in the serum level, the grade of this dysfunction in the reproductive system was worsened. A reduction of the prolactin serum level to 40 ng/ml seems to be the basis for spontaneous ovulation. Present therapeutic possibilities and as a result the reversibility of this disturbance after interruption of prolactin inhibitors, we find that long-therm therapy is necessary. PMID:6933737

  9. Method of sterilization using ozone

    NASA Technical Reports Server (NTRS)

    Murphy, Oliver J. (Inventor); Hitchens, G. Duncan (Inventor)

    2002-01-01

    Methods of using ozone have been developed which sterilize instruments and medical wastes, oxidize, organics found in wastewater, clean laundry, break down contaminants in soil into a form more readily digested by microbes, kill microorganisms present in food products, and destroy toxins present in food products. The preferred methods for killing microorganism and destroying toxins use pressurized, humidified, and concentrated ozone produced by an electrochemical cell.

  10. Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer

    NASA Astrophysics Data System (ADS)

    Li, Si; Zhang, Yangde; Liu, Weidong

    2006-09-01

    The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.

  11. Sterile neutrinos as dark matter

    SciTech Connect

    Dodelson, S.; Widrow, L.M. |

    1993-03-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed or sterile neutrinos. This model has been studied extensively in the context of the hot dark matter scenario. We reexamine this model and find that hot, warm, and cold dark matter are all possibilities. We focus on the case where sterile neutrinos are the dark matter. Since their only direct coupling is to left-handed or active neutrinos, the most efficient production mechanism is via neutrino oscillations. If the production rate is always less than the expansion rate, then these neutrinos will never be in thermal equilibrium. However, they may still play a significant role in the dynamics of the Universe and possibly provide the missing mass necessary for closure. We consider a single generation of neutrino fields ({nu}{sub L}, {nu}{sub R}) with a Dirac mass, {mu}, and a Majorana mass for the right-handed components only, M. For M {much_gt} {mu} we show that the number density of sterile neutrinos is proportional to {mu}{sup 2}/M so that the energy density today is independent of M. However M is crucial in determining the large scale structure of the Universe. In particular, M {approx_equal} 0.1--1.0 key leads to warm dark matter and a structure formation scenario that may have some advantages over both the standard hot and cold dark matter scenarios.

  12. Sterile neutrinos as dark matter

    SciTech Connect

    Dodelson, S. ); Widrow, L.M. . Dept. of Physics Toronto Univ., ON . Canadian Inst. for Theoretical Astrophysics)

    1993-03-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed or sterile neutrinos. This model has been studied extensively in the context of the hot dark matter scenario. We reexamine this model and find that hot, warm, and cold dark matter are all possibilities. We focus on the case where sterile neutrinos are the dark matter. Since their only direct coupling is to left-handed or active neutrinos, the most efficient production mechanism is via neutrino oscillations. If the production rate is always less than the expansion rate, then these neutrinos will never be in thermal equilibrium. However, they may still play a significant role in the dynamics of the Universe and possibly provide the missing mass necessary for closure. We consider a single generation of neutrino fields ([nu][sub L], [nu][sub R]) with a Dirac mass, [mu], and a Majorana mass for the right-handed components only, M. For M [much gt] [mu] we show that the number density of sterile neutrinos is proportional to [mu][sup 2]/M so that the energy density today is independent of M. However M is crucial in determining the large scale structure of the Universe. In particular, M [approx equal] 0.1--1.0 key leads to warm dark matter and a structure formation scenario that may have some advantages over both the standard hot and cold dark matter scenarios.

  13. Effectiveness of two types of sterilizers on the contents of sharps containers.

    PubMed

    Palenik, C J; Golden, L C

    1994-04-01

    The purpose of this study was to evaluate the killing effect that a gravity steam autoclave (GSA), a high-vacuum steam sterilizer (HVA) or an unsaturated chemical vapor sterilizer (UCV) had on endospores present on strips or applied to dental needles within three sizes of sharps containers. Commercial spore strips containing 1.7 x 10(5) Bacillus stearothermophilus endospores were used, while the needles were soiled with an equal number of spores or with spores mixed with blood. Needles were tested capped and uncapped. Initial operating conditions were for the: (1) GSA were 129 kPa at 124 degrees C for 30 minutes; (2) HVA were 214 kPa at 131 degrees C for 10 minutes and (3) UCV, 172 kPa at 134 degrees C for 20 minutes. Strips and needles were placed within 3/4 filled containers. Fill materials consisted of needles, syringes, plastic sheaths and scalpel blades. Containers were processed upward or on their sides. Twenty-five strips or needles comprised a test group for each operational parameter. Processed strips and needles were aerobically cultured at 56 degrees C for 7 days. If sterilization was not accomplished after the initial period, additional exposure time was added. Results included: (1) soiled needles are more difficult than strips to sterilize; (2) capping or the presence of blood did not affect sterilization efficiency; (3) container positioning was important only for the smallest container; (4) additional exposure time was usually required when sterilizing soiled needles; (5) the HVA killed all spore challenges in a single sterilization cycle and (6) GSA and UCV were approximately equal in sterilization efficiency.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8054195

  14. Sterile Neutrinos in Cold Climates

    SciTech Connect

    Jones, Benjamin J.P.

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  15. Plasma Sterilization: New Epoch in Medical Textiles

    NASA Astrophysics Data System (ADS)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  16. 7 CFR 4290.200 - Adequate capital for RBICs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Adequate capital for RBICs. 4290.200 Section 4290.200 Agriculture Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND... Qualifications for the RBIC Program Capitalizing A Rbic § 4290.200 Adequate capital for RBICs. You must meet...

  17. 13 CFR 107.200 - Adequate capital for Licensees.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 13 Business Credit and Assistance 1 2011-01-01 2011-01-01 false Adequate capital for Licensees... INVESTMENT COMPANIES Qualifying for an SBIC License Capitalizing An Sbic § 107.200 Adequate capital for... Licensee, and to receive Leverage. (a) You must have enough Regulatory Capital to provide...

  18. 13 CFR 107.200 - Adequate capital for Licensees.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Adequate capital for Licensees... INVESTMENT COMPANIES Qualifying for an SBIC License Capitalizing An Sbic § 107.200 Adequate capital for... Licensee, and to receive Leverage. (a) You must have enough Regulatory Capital to provide...

  19. 7 CFR 4290.200 - Adequate capital for RBICs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Adequate capital for RBICs. 4290.200 Section 4290.200 Agriculture Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND... Qualifications for the RBIC Program Capitalizing A Rbic § 4290.200 Adequate capital for RBICs. You must meet...

  20. 10 CFR 1304.114 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Responsibility for maintaining adequate safeguards. 1304.114 Section 1304.114 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.114 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining...

  1. 40 CFR 716.25 - Adequate file search.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Adequate file search. 716.25 Section 716.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT HEALTH AND SAFETY DATA REPORTING General Provisions § 716.25 Adequate file search. The scope of...

  2. 40 CFR 51.354 - Adequate tools and resources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Adequate tools and resources. 51.354... Requirements § 51.354 Adequate tools and resources. (a) Administrative resources. The program shall maintain the administrative resources necessary to perform all of the program functions including...

  3. 40 CFR 51.354 - Adequate tools and resources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Adequate tools and resources. 51.354... Requirements § 51.354 Adequate tools and resources. (a) Administrative resources. The program shall maintain the administrative resources necessary to perform all of the program functions including...

  4. 40 CFR 51.354 - Adequate tools and resources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Adequate tools and resources. 51.354... Requirements § 51.354 Adequate tools and resources. (a) Administrative resources. The program shall maintain the administrative resources necessary to perform all of the program functions including...

  5. 40 CFR 51.354 - Adequate tools and resources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Adequate tools and resources. 51.354... Requirements § 51.354 Adequate tools and resources. (a) Administrative resources. The program shall maintain the administrative resources necessary to perform all of the program functions including...

  6. 40 CFR 716.25 - Adequate file search.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Adequate file search. 716.25 Section... ACT HEALTH AND SAFETY DATA REPORTING General Provisions § 716.25 Adequate file search. The scope of a person's responsibility to search records is limited to records in the location(s) where the...

  7. 40 CFR 716.25 - Adequate file search.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Adequate file search. 716.25 Section... ACT HEALTH AND SAFETY DATA REPORTING General Provisions § 716.25 Adequate file search. The scope of a person's responsibility to search records is limited to records in the location(s) where the...

  8. 40 CFR 716.25 - Adequate file search.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Adequate file search. 716.25 Section... ACT HEALTH AND SAFETY DATA REPORTING General Provisions § 716.25 Adequate file search. The scope of a person's responsibility to search records is limited to records in the location(s) where the...

  9. 40 CFR 716.25 - Adequate file search.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Adequate file search. 716.25 Section... ACT HEALTH AND SAFETY DATA REPORTING General Provisions § 716.25 Adequate file search. The scope of a person's responsibility to search records is limited to records in the location(s) where the...

  10. 10 CFR 1304.114 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Responsibility for maintaining adequate safeguards. 1304.114 Section 1304.114 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.114 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining...

  11. 10 CFR 1304.114 - Responsibility for maintaining adequate safeguards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Responsibility for maintaining adequate safeguards. 1304.114 Section 1304.114 Energy NUCLEAR WASTE TECHNICAL REVIEW BOARD PRIVACY ACT OF 1974 § 1304.114 Responsibility for maintaining adequate safeguards. The Board has the responsibility for maintaining...

  12. 10 CFR 503.35 - Inability to obtain adequate capital.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Inability to obtain adequate capital. 503.35 Section 503.35 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS NEW FACILITIES Permanent Exemptions for New Facilities § 503.35 Inability to obtain adequate capital. (a) Eligibility. Section 212(a)(1)(D)...

  13. 10 CFR 503.35 - Inability to obtain adequate capital.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Inability to obtain adequate capital. 503.35 Section 503.35 Energy DEPARTMENT OF ENERGY (CONTINUED) ALTERNATE FUELS NEW FACILITIES Permanent Exemptions for New Facilities § 503.35 Inability to obtain adequate capital. (a) Eligibility. Section 212(a)(1)(D)...

  14. 15 CFR 970.404 - Adequate exploration plan.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Certification of Applications § 970.404 Adequate exploration plan. Before he may certify an application, the Administrator must find... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Adequate exploration plan....

  15. 15 CFR 970.404 - Adequate exploration plan.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ENVIRONMENTAL DATA SERVICE DEEP SEABED MINING REGULATIONS FOR EXPLORATION LICENSES Certification of Applications § 970.404 Adequate exploration plan. Before he may certify an application, the Administrator must find... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Adequate exploration plan....

  16. "Something Adequate"? In Memoriam Seamus Heaney, Sister Quinlan, Nirbhaya

    ERIC Educational Resources Information Center

    Parker, Jan

    2014-01-01

    Seamus Heaney talked of poetry's responsibility to represent the "bloody miracle", the "terrible beauty" of atrocity; to create "something adequate". This article asks, what is adequate to the burning and eating of a nun and the murderous gang rape and evisceration of a medical student? It considers Njabulo…

  17. Radiation sterilization of new drug delivery systems

    PubMed Central

    Abuhanoğlu, Gürhan

    2014-01-01

    Radiation sterilization has now become a commonly used method for sterilization of several active ingredients in drugs or drug delivery systems containing these substances. In this context, many applications have been performed on the human products that are required to be sterile, as well as on pharmaceutical products prepared to be developed. The new drug delivery systems designed to deliver the medication to the target tissue or organ, such as microspheres, nanospheres, microemulsion, and liposomal systems, have been sterilized by gamma (γ) and beta (β) rays, and more recently, by e-beam sterilization. In this review, the sterilization of new drug delivery systems was discussed other than conventional drug delivery systems by γ irradiation. PMID:24936306

  18. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    PubMed Central

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  19. Locating the voices of the sterilized.

    PubMed

    Kluchin, Rebecca M

    2007-01-01

    Scholars have been studying eugenics and sterilization for years, but only recently have some begun to examine these issues from the point of view of those sterilized. This is in large part because so few records containing the voices of the sterilized exist or are accessible to scholars. This essay examines my own effort to recover the voices of women sterilized in the post-baby boom United States from the "bottom up" and includes my own experience researching and writing Fit to Be Tied?: Sterilization and Reproductive Rights in America, 1960-1984. It represents the beginning of a discussion about locating and using sources containing the voices of the sterilized and working with the limitations inherent to them. PMID:18175455

  20. Hysteroscopic Sterilization: History and Current Methods

    PubMed Central

    Greenberg, James A

    2008-01-01

    For many practicing obstetrician-gynecologists, tubal ligation was the gold standard by which female sterilization techniques were measured. Yet gynecologic surgeons have simultaneously sought to occlude the fallopian tubes transcervically to avoid discomfort and complications associated with transabdominal approaches. In this review, the history of transcervical sterilization is discussed. Past, current, and upcoming techniques are reviewed. This article focuses on interval sterilization techniques, thus removing post-vaginal and post-cesarean delivery tubal ligations from the discussion. PMID:19015762

  1. New developments in disinfection and sterilization.

    PubMed

    Wallace, Craig A

    2016-05-01

    A review of regulatory clearances for selected new sterilization and disinfection products for the period January 2012-June 2015 indicates continued leverage of established technologies for steam and low-temperature sterilization, and high-level disinfection. New products in these areas were typically modified and improved versions of existing products, with the exception of a new combination hydrogen peroxide/ozone sterilizer. Development of new low-temperature sterilization technologies to address continued evolution of complex medical devices is expected to continue. PMID:27131131

  2. Ramifications of a sterile Mars

    NASA Astrophysics Data System (ADS)

    Levin, Gilbert V.

    2011-10-01

    The seldom considered ramifications of a sterile Mars are explored. Very much is now known about the environment on Mars. Herein, the individual and collective environmental parameters are examined with particular consideration of those that might be inimical to life as we know it, or as might reasonably be assumed to be so to alien life. It is shown that no single measurement or combination of them precludes the ability of Mars to support even a wide number of terrestrial microbial species, let alone the likely greater tolerance and/or adaptability of possible alien life forms. Some yet unknown factor or combination of factors would have to be responsible for Mars' failure to generate life or to successfully harbor viable forms received from space. Since Mars is so Earth-like, the red planet's sterility could deliver a fatal blow to the growing concept of a cosmic Biologic Imperative, and would raise the daunting prospect that Earth is a unique or a very rare habitat.

  3. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  4. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.12 Sterility. (a) The test. Except as provided in paragraph (h) of this section, manufacturers of biological products must perform sterility testing of each lot of each biological product's final container material or other material, as appropriate and...

  5. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.12 Sterility. (a) The test. Except as provided in paragraph (h) of this section, manufacturers of biological products must perform sterility testing of each lot of each biological product's final container material or other material, as appropriate and...

  6. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  7. Eugenics and Involuntary Sterilization: 1907-2015.

    PubMed

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups. PMID:26322647

  8. Monitoring dental sterilizers' effectiveness using biological indicators.

    PubMed

    Nickerson, A; Bhuta, P; Orton, G; Alvin, B

    1990-02-01

    The purpose of this study was to evaluate the effectiveness of dental office sterilizers as measured by their ability to kill bacterial spores present on biological indicator strips. The biological indicators used in this study contained two different spores, Bacillus stearothermophilus and Bacillus subtilis (Spordi, AMSCO/Medical Products). Ten spore test strips were sent to 87 dental offices; 51 sterilizers were tested. Office personnel were instructed to place four strips in the center of a normal sterilization load and process the load. The procedure was repeated on a second day. The processed strips, along with two unprocessed control strips, were returned by mail for laboratory culturing. The results indicated the overall failure rate (positive test) of sterlizers tested for both days was 51% at the culturing temperature of 37 degrees C and 33.3% at 55 degrees C. McNemar's test indicated a significant difference (p less than .03) in sterilization failures associated with the type and number of microorganisms present on the test strips. This study also showed that the more times a sterilizer was tested, the more likely a failure would occur. Overall, an alarming number of sterilizers (64.7%) were not effective in killing all the spores present on the indicator strips. When office personnel were given information for improving sterilizer performance, there was a noticeable reduction in sterilization failures following retesting. PMID:2370583

  9. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  10. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  11. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  12. Viking heat sterilization - Progress and problems

    NASA Technical Reports Server (NTRS)

    Daspit, L. P.; Cortright, E. M.; Stern, J. A.

    1974-01-01

    The Viking Mars landers to be launched in 1975 will carry experiments in biology, planetology, and atmospheric physics. A terminal dry-heat sterilization process using an inert gas was chosen to meet planetary quarantine requirements and preclude contamination of the biology experiment by terrestrial organisms. Deep sterilization is performed at the component level and terminal surface sterilization at the system level. Solutions to certain component problems relating to sterilization are discussed, involving the gyroscope, tape recorder, battery, electronic circuitry, and outgassing. Heat treatment placed special requirements on electronic packaging, including fastener preload monitoring and solder joints. Chemical and physical testing of nonmetallic materials was performed to establish data on their behavior in heat-treatment and vacuum environments. A Thermal Effects Test Model and a Proof Test Capsule were used. It is concluded that a space vehicle can be designed and fabricated to withstand heat sterilization requirements.

  13. Disinfection, sterilization, and antisepsis: An overview.

    PubMed

    Rutala, William A; Weber, David J

    2016-05-01

    All invasive procedures involve contact by a medical device or surgical instrument with a patient's sterile tissue or mucous membranes. The level of disinfection or sterilization is dependent on the intended use of the object: critical (items that contact sterile tissue such as surgical instruments), semicritical (items that contact mucous membrane such as endoscopes), and noncritical (devices that contact only intact skin such as stethoscopes) items require sterilization, high-level disinfection and low-level disinfection, respectively. Cleaning must always precede high-level disinfection and sterilization. Antiseptics are essential to infection prevention as part of a hand hygiene program as well as several other uses such as surgical hand antisepsis and pre-operative skin preparation. PMID:27131128

  14. Sterilization and contraceptive services in Catholic hospitals.

    PubMed

    O'Lane, J M

    1979-02-15

    Sterilization and contraceptive practices in United States Catholic hospitals were surveyed by anonymous mail questionnaires, obtaining a 57% response rate (340 of 598). Twenty per cent of the hospitals permitted medically indicated sterilization operations. Forty-seven per cent of those hospitals not allowing sterilization procedures reported that their medical staffs were interested in performing medically indicated sterilizations. The types of contraceptive services offered varied widely. The rhythm method was most frequently available, with oral contraceptives in second place; many hospitals did not provide any family-planning services; 13% utilized all types of contraception. The thesis is advanced that improvement in availability of sterilization and contraceptive services is a duty of hospital medical staffs. PMID:433994

  15. Space directorate research and technology accomplishments for FY 1988

    NASA Technical Reports Server (NTRS)

    Avery, Don E. (Compiler)

    1989-01-01

    The major accomplishments and test highlights for FY 1988 that occurred in the Space Dirctorate are given. Accomplishments and test highlights are presented by Division and Branch. The presented information will be useful in program coordination with government organizations, universities, and industry in areas of mutual interest.

  16. Sex and Ethnic-Group Differences on Accomplishments Measures.

    ERIC Educational Resources Information Center

    Stricker, Lawrence J.; Rock, Donald A.; Bennett, Randy Elliot

    2001-01-01

    Studied sex and ethnic group differences on 6 scales that measure accomplishments for 739 male and 1,746 female graduate school applicants. With the exception of the scale measuring mechanical accomplishment, men and women did not differ in performance, and ethnic groups did not differ on any scale. (SLD)

  17. Accomplishments in 2008 in the Management of Localized Pancreatic Cancer

    PubMed Central

    O’Reilly, Eileen M.; Lutz, Manfred P.; Neuhaus, Peter

    2009-01-01

    SUMMARY Overview of the DiseaseIncidenceRisk FactorsPrognostic or Predictive FactorsCurrent General Therapy StandardsAccomplishments During the YearTherapyBiomarkersBasic ScienceWhat Needs to Be Done?Applications of the AccomplishmentsControversies and DisagreementsFuture DirectionsComments on ResearchObstacles to Progress PMID:20011563

  18. Space directorate research and technology accomplishments for fiscal year 1987

    NASA Technical Reports Server (NTRS)

    Avery, Don E.

    1988-01-01

    The major accomplishments and test highlights of the Space Directorate of NASA Langley Research Center for FY87 are presented. Accomplishments and test highlights are listed by Division and Branch. This information should be useful in coordinating programs with government organizations, universities, and industry in areas of mutual interest.

  19. Gender-Role Orientation, Creative Accomplishments and Cognitive Styles.

    ERIC Educational Resources Information Center

    Hittner, James B.; Daniels, Jennifer R.

    2002-01-01

    This study examined the association of gender-role orientation to creative accomplishments and cognitive styles in 127 college students. Results indicated that the gender role orientation of instrumentality was positively associated with creative accomplishments in the business venture domain and that androgynous, versus non-androgynous,…

  20. Vapor Hydrogen Peroxide Sterilization Certification

    NASA Astrophysics Data System (ADS)

    Chen, Fei; Chung, Shirley; Barengoltz, Jack

    For interplanetary missions landing on a planet of potential biological interest, United States NASA planetary protection currently requires that the flight system must be assembled, tested and ultimately launched with the intent of minimizing the bioload taken to and deposited on the planet. Currently the only NASA approved microbial reduction method is dry heat sterilization process. However, with utilization of such elements as highly sophisticated electronics and sensors in modern spacecraft, this process presents significant materials challenges and is thus an undesirable bioburden reduction method to design engineers. The objective of this work is to introduce vapor hydrogen peroxide (VHP) as an alternative to dry heat microbial reduction to meet planetary protection requirements. The VHP sterilization technology is widely used by the medical industry, but high doses of VHP may degrade the performance of flight hardware, or compromise material compatibility. The goal of our study is determine the minimum VHP process conditions for PP acceptable microbial reduction levels. A series of experiments were conducted using Geobacillus stearothermophilus to determine VHP process parameters that provided significant reductions in spore viability while allowing survival of sufficient spores for statistically significant enumeration. In addition to the obvious process parameters -hydrogen peroxide concentration, number of pulses, and exposure duration -the investigation also considered the possible effect of environmental pa-rameters. Temperature, relative humidity, and material substrate effects on lethality were also studied. Based on the results, a most conservative D value was recommended. This recom-mended D value was also validated using VHP "hardy" strains that were isolated from clean-rooms and environmental populations collected from spacecraft relevant areas. The efficiency of VHP at ambient condition as well as VHP material compatibility will also be

  1. Iran eases limits on sterilization.

    PubMed

    Roudi, N

    1991-03-01

    The government of Iran announced in November 1990, in an abrupt reversal of previous policies, the legislation of sterilization and its provision free-of-charge upon request, as well as the distribution of other contraceptive gratis. At the time of the Islamic Revolution in 1979 the government adopted a pronatalist policy, family planning programs were interrupted, legal ages of marriage were lowered, and barriers against polygamy were loosened. Iran had a 3.5% growth rate in 1990 and a total fertility rate of 6.3 lifetime births/woman. After the end of the war between Iran and Iraq in 1988, the population explosion became an obstacle to reconstruction. In 1950, the population numbered 14.2 million; by 1970 it had doubled to 28.4 million. In 1990, the country had 54.6 million people. According to a 1990 UN assessment the population will soar to 100 million by 2020. Over 8 million live in Tehran where overcrowding, traffic congestion, air pollution, and high living costs are the norm. the 1989 National Birth Control Policy Summary adopted targets to reduce the average number of lifetime births per woman to 4 children and natural growth rate to 2.3% by 2011, and to provide family planning to 24% of reproductive-age women whereby 1 million conceptions would be prevented. Indirect measures to curb fertility include raising literacy promoting the education of girls, improving the status and health conditions of women, and reducing maternal and child mortality. A media campaign has started to encourage a small family model. The low legal, social, educational, and employment status of women poses obstacles to this plan, however, the revision of laws that conflict with these goals has been urged. In other Islamic countries such as Turkey, Tunisia, Indonesia, Pakistan, and Bangladesh, female sterilization is legal. Abortion in Iran remains banned except for saving the life of the mother. PMID:12343087

  2. Arabidopsis: An Adequate Model for Dicot Root Systems?

    PubMed

    Zobel, Richard W

    2016-01-01

    The Arabidopsis root system is frequently considered to have only three classes of root: primary, lateral, and adventitious. Research with other plant species has suggested up to eight different developmental/functional classes of root for a given plant root system. If Arabidopsis has only three classes of root, it may not be an adequate model for eudicot plant root systems. Recent research, however, can be interpreted to suggest that pre-flowering Arabidopsis does have at least five (5) of these classes of root. This then suggests that Arabidopsis root research can be considered an adequate model for dicot plant root systems. PMID:26904040

  3. An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft

    NASA Technical Reports Server (NTRS)

    Farmer, F. H.; Fuller, H. V.; Hueschen, R. M.

    1973-01-01

    A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.

  4. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    PubMed

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs. PMID:26647625

  5. New sterilization technologies alternative to ethylene oxide

    NASA Astrophysics Data System (ADS)

    Tabrizian, Maryam; Lerouge, Sophie; Debrie, Anne; Yahia, L'Hocine

    1997-06-01

    Sterilization of biomedical devices may induce bulk and surface modification, responsible for the decrease or loss of their biofunctionality. Pure ethylene oxide (EO) at low temperature and new alternative techniques such as cold gas plasma sterilization have been developed for heat-sensitive polymers. There is a lack of the knowledge concerning their safety in terms of materials damage and consequences on the biofunctionality of sterilized devices. The objective of our work consists in studying bulk and surface changes in biomedical devices induced by these two sterilization techniques. Samples from PVC, Polyurethane, Polyacrylate and Polyethylene-based medical devices are subjected to 1, 5, and 10 sterilization cycles by Steri-Vac-3M (pure EO), Sterrad-100$TM, J&J (gas plasma + H2O2), and studied by X-rays photoelectron spectroscopy. Preliminary results show an increasing in Oxygen/Carbon ratio by a factor of 1.3 to 4.4 between the first and tenth cycle indicating the surface oxidation by gas plasma sterilization processes. Some changes in C-C chemical bounding are associated with EO sterilization.

  6. Prospects for vector control through sterilization procedures

    PubMed Central

    Smith, Carroll N.

    1963-01-01

    Interest in sterilization as a possible method for controlling insects of public health importance can be said to have arisen first in the mid-fifties, when the screw-worm fly was successfully eradicated from the island of Curaçao by the release over the entire island of large numbers of male flies sterilized by gamma-radiation. Since then, many studies on the sterilization of various insect vectors of disease have been carried out. This paper reviews these studies and discusses the present position regarding vector control by sterilization procedures, with special reference to the use of chemosterilants. These compounds have certain advantages over radiation since they can be used not only as a substitute for X-rays or gamma-rays in the sterilization of insects specially reared for release in large numbers, but also as a means of inducing sterility in natural populations of insects. The author emphasizes that chemosterilants cannot at present be recommended as a practical control or eradication procedure for any vector species of insect, but considers that this extension of the sterilization method holds great promise and merits intensive investigation. PMID:20604181

  7. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  8. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    PubMed Central

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  9. Spore-Forming Bacteria that Resist Sterilization

    NASA Technical Reports Server (NTRS)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  10. Laparoscopic sterilization in HIV-1-positive women.

    PubMed

    Intaraprasert, S; Taneepanichskul, S; Chaturachinda, K

    1996-11-01

    Laparoscopic sterilizations in HIV-1-positive women were performed. Patients, who were HIV-1-positive, underwent voluntary laparoscopic sterilization. The mean age of patients was 27.5 +/- 3.8 years. Most were of low socioeconomic status. The mean duration of the operation was 14.4 +/- 5.4 min. No accidental injury to the surgical team was recorded, and no complications occurred among the patients. It was concluded that laparoscopic sterilization in HIV-positive patients was safe with low risk of HIV transmission to the surgical team. PMID:8934065

  11. Dynamic ultraviolet sterilization of different implant types.

    PubMed

    Delgado, A A; Schaaf, N G

    1990-01-01

    This paper investigates the use of the dynamic ultraviolet sterilization process with various dental implants, stainless steel orthopedic cortical bone screws, and polysulfone polymer healing caps. These biomaterials were inoculated with the spores of Bacillus subtilis and Bacillus stearothermophilus. They were then exposed to dynamic ultraviolet radiation in the chamber of a BUD Ultraviolet Device. Samples were incubated in trypticase soy broth at 37 degrees C and 56 degrees C, and they were subcultured onto an enriched agar medium. Results indicate that 16 seconds of dynamic ultraviolet radiation is effective in sterilizing these materials. This is significantly less time than other sterilization techniques presently used. PMID:2133336

  12. Is the Marketing Concept Adequate for Continuing Education?

    ERIC Educational Resources Information Center

    Rittenburg, Terri L.

    1984-01-01

    Because educators have a social responsibility to those they teach, the marketing concept may not be adequate as a philosophy for continuing education. In attempting to broaden the audience for continuing education, educators should consider a societal marketing concept to meet the needs of the educationally disadvantaged. (SK)

  13. Comparability and Reliability Considerations of Adequate Yearly Progress

    ERIC Educational Resources Information Center

    Maier, Kimberly S.; Maiti, Tapabrata; Dass, Sarat C.; Lim, Chae Young

    2012-01-01

    The purpose of this study is to develop an estimate of Adequate Yearly Progress (AYP) that will allow for reliable and valid comparisons among student subgroups, schools, and districts. A shrinkage-type estimator of AYP using the Bayesian framework is described. Using simulated data, the performance of the Bayes estimator will be compared to…

  14. 9 CFR 305.3 - Sanitation and adequate facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Sanitation and adequate facilities. 305.3 Section 305.3 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION...

  15. Understanding Your Adequate Yearly Progress (AYP), 2011-2012

    ERIC Educational Resources Information Center

    Missouri Department of Elementary and Secondary Education, 2011

    2011-01-01

    The "No Child Left Behind Act (NCLB) of 2001" requires all schools, districts/local education agencies (LEAs) and states to show that students are making Adequate Yearly Progress (AYP). NCLB requires states to establish targets in the following ways: (1) Annual Proficiency Target; (2) Attendance/Graduation Rates; and (3) Participation Rates.…

  16. Assessing Juvenile Sex Offenders to Determine Adequate Levels of Supervision.

    ERIC Educational Resources Information Center

    Gerdes, Karen E.; And Others

    1995-01-01

    This study analyzed the internal consistency of four inventories used by Utah probation officers to determine adequate and efficacious supervision levels and placement for juvenile sex offenders. Three factors accounted for 41.2 percent of variance (custodian's and juvenile's attitude toward intervention, offense characteristics, and historical…

  17. 34 CFR 200.13 - Adequate yearly progress in general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Adequate yearly progress in general. 200.13 Section 200.13 Education Regulations of the Offices of the Department of Education OFFICE OF ELEMENTARY AND SECONDARY EDUCATION, DEPARTMENT OF EDUCATION TITLE I-IMPROVING THE ACADEMIC ACHIEVEMENT OF THE...

  18. 34 CFR 200.20 - Making adequate yearly progress.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Making adequate yearly progress. 200.20 Section 200.20 Education Regulations of the Offices of the Department of Education OFFICE OF ELEMENTARY AND SECONDARY EDUCATION, DEPARTMENT OF EDUCATION TITLE I-IMPROVING THE ACADEMIC ACHIEVEMENT OF THE DISADVANTAGED...

  19. Do Beginning Teachers Receive Adequate Support from Their Headteachers?

    ERIC Educational Resources Information Center

    Menon, Maria Eliophotou

    2012-01-01

    The article examines the problems faced by beginning teachers in Cyprus and the extent to which headteachers are considered to provide adequate guidance and support to them. Data were collected through interviews with 25 school teachers in Cyprus, who had recently entered teaching (within 1-5 years) in public primary schools. According to the…

  20. Idaho National Laboratory Mission Accomplishments, Fiscal Year 2015

    SciTech Connect

    Allen, Todd Randall; Wright, Virginia Latta

    2015-09-01

    A summary of mission accomplishments for the research organizations at the Idaho National Laboratory for FY 2015. Areas include Nuclear Energy, National and Homeland Security, Science and Technology Addressing Broad DOE Missions; Collaborations; and Stewardship and Operation of Research Facilities.

  1. Enhanced surveillance program FY97 accomplishments. Progress report

    SciTech Connect

    Mauzy, A.; Laake, B.

    1997-10-01

    This annual report is one volume of the Enhanced Surveillance Program (ESP) FY97 Accomplishments. The complete accomplishments report consists of 11 volumes. Volume 1 includes an ESP overview and a summary of selected unclassified FY97 program highlights. Volume 1 specifically targets a general audience, reflecting about half of the tasks conducted in FY97 and emphasizing key program accomplishments and contributions. The remaining volumes of the accomplishments report are classified, organized by program focus area, and present in technical detail the progress achieved in each of the 104 FY97 program tasks. Focus areas are as follows: pits; high explosives; organics; dynamics; diagnostics; systems; secondaries; nonnuclear materials; nonnuclear components; and Surveillance Test Program upgrades.

  2. Process development accomplishments: Waste and hazard minimization, FY 1991

    SciTech Connect

    Homan, D.A.

    1991-11-04

    This report summarizes significant technical accomplishments of the Mound Waste and Hazard Minimization Program for FY 1991. The accomplishments are in one of eight major areas: environmentally responsive cleaning program; nonhalogenated solvent trials; substitutes for volatile organic compounds; hazardous material exposure minimization; nonhazardous plating development; explosive processing waste reduction; tritium capture without conversion to water; and robotic assembly. Program costs have been higher than planned.

  3. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: Sterilization to polyurethane

    NASA Astrophysics Data System (ADS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu

    1995-09-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization.

  4. [Low-temperature sterilization for the surgical infection prophylaxis].

    PubMed

    Kornev, I I; Baranov, G A; Ul'ianov, V I

    2011-01-01

    The comparative characteristic of the accepted methods of low-temperature sterilization of medical equipment is given. Special attention is devoted to the surgical infection prophylaxis. The efficacy, expediency and safety of gas sterilization with ethilenoxide is proved. Plasmic methods of sterilization is recommended for use together with other methods of low-temperature sterilization. PMID:21716218

  5. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  6. Neutrino Oscillations with Three Active and Three Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Kisslinger, Leonard S.

    2016-07-01

    This is an extension of estimates of the probability of μ to e neutrino oscillation with one sterile neutrino to three sterile neutrinos, using a 6x6 matrix. Since the mixing angle for only one sterile neutrino has been experimentally determined, we estimate the μ to e neutrino oscillation probability with different mixing angles for two of the sterile neutrinos.

  7. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  8. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  9. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  10. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  11. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  12. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  13. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  14. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  15. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  16. ETHYLENE OXIDE CONTROL TECHNOLOGY DEVELOPMENT FOR HOSPITAL STERILIZERS

    EPA Science Inventory

    The report discusses the development of ethylene oxide (EO) control technology for hospital sterilizers. Hospitals sterilize heat-sensitive items in gas sterilizers that use a mixture of EO (12 wt %) and a chlorofluorocarbon (CFC) (88 wt %). The active sterilizing agent is EO. Th...

  17. Encapsulation process sterilizes and preserves surgical instruments

    NASA Technical Reports Server (NTRS)

    Montgomery, L. C.; Morelli, F. A.

    1964-01-01

    Ethylene oxide is blended with an organic polymer to form a sterile material for encapsulating surgical instruments. The material does not bond to metal and can be easily removed when the instruments are needed.

  18. The sterilization of gutta-percha points.

    PubMed

    Ehrmann, E H; Boquest, A; Faine, S

    1975-06-01

    The traditional methods employed for the sterilization of gutta-percha points are unsatisfactory. The use of propylene oxide for this purpose is described and experimental evidence is advanced to support this use. PMID:169776

  19. Sterile post-traumatic immunosuppression.

    PubMed

    Islam, Md Nahidul; Bradley, Benjamin A; Ceredig, Rhodri

    2016-04-01

    After major trauma, the human immune system initiates a series of inflammatory events at the injury site that is later followed by suppression of local inflammation favoring the repair and remodeling of the damaged tissues. This local immune response involves complex interactions between resident cells such as macrophages and dendritic cells, soluble mediators such as cytokines and chemokines, and recruited cells such as neutrophils, monocytes and mesenchymal stromal cells. If of sufficient magnitude, these initial immune responses nevertheless have systemic consequences resulting in a state called post-traumatic immunosuppression (PTI). However, controversy exists regarding the exact immunological changes occurring in systemic compartments triggered by these local immune responses. PTI is one of the leading causes of post-surgical mortality and makes patients vulnerable to hospital-acquired infections, multiple organ failure and many other complications. In addition, hemorrhage, blood transfusion, immunesenescence and immunosuppressant drugs aggravate PTI. PTI has been intensively studied, but published results are frequently cloudy. The purpose of this review is to focus on the contributions made by different responsive modalities to immunosuppression following sterile trauma and to try to integrate these into an overall scheme of PTI. PMID:27195120

  20. Sterile post-traumatic immunosuppression

    PubMed Central

    Islam, Md Nahidul; Bradley, Benjamin A; Ceredig, Rhodri

    2016-01-01

    After major trauma, the human immune system initiates a series of inflammatory events at the injury site that is later followed by suppression of local inflammation favoring the repair and remodeling of the damaged tissues. This local immune response involves complex interactions between resident cells such as macrophages and dendritic cells, soluble mediators such as cytokines and chemokines, and recruited cells such as neutrophils, monocytes and mesenchymal stromal cells. If of sufficient magnitude, these initial immune responses nevertheless have systemic consequences resulting in a state called post-traumatic immunosuppression (PTI). However, controversy exists regarding the exact immunological changes occurring in systemic compartments triggered by these local immune responses. PTI is one of the leading causes of post-surgical mortality and makes patients vulnerable to hospital-acquired infections, multiple organ failure and many other complications. In addition, hemorrhage, blood transfusion, immunesenescence and immunosuppressant drugs aggravate PTI. PTI has been intensively studied, but published results are frequently cloudy. The purpose of this review is to focus on the contributions made by different responsive modalities to immunosuppression following sterile trauma and to try to integrate these into an overall scheme of PTI. PMID:27195120

  1. Experimental Study of Sterilizing Molds by Ultrasound

    NASA Astrophysics Data System (ADS)

    Ren, Jin-lian; Niu, Yong

    1998-02-01

    An ultrasound method of sterilizing aspergillus flavus and fusarium is proposed and demonstrated. The dependence of sterilizing effect on ultrasonic intensity, frequency, and treatment time is experimentally investigated. The density of surviving spores decreases first with increasing ultrasonic frequency and then increases with the further increase of the frequency, that is to say, there exists the optimum frequency 26 kHz at which the killing rate is near 100%. The killing rate seems proportional to the intensity and the time.

  2. Health technology assessment: Off-site sterilization

    PubMed Central

    Dehnavieh, Reza; Mirshekari, Nadia; Ghasemi, Sara; Goudarzi, Reza; Haghdoost, AliAkbar; Mehrolhassani, Mohammad Hossain; Moshkani, Zahra; Noori Hekmat, Somayeh

    2016-01-01

    Background: Every year millions of dollars are expended to equip and maintain the hospital sterilization centers, and our country is not an exception of this matter. According to this, it is important to use more effective technologies and methods in health system in order to reach more effectiveness and saving in costs. This study was conducted with the aim of evaluating the technology of regional sterilization centers. Methods: This study was done in four steps. At the first step, safety and effectiveness of technology was studied via systematic study of evidence. The next step was done to evaluate the economical aspect of off-site sterilization technology using gathered data from systematic review of the texts which were related to the technology and costs of off-site and in-site hospital sterilization. Third step was conducted to collect experiences of using technology in some selected hospitals around the world. And in the last step different aspects of acceptance and use of this technology in Iran were evaluated. Results: Review of the selected articles indicated that efficacy and effectiveness of this technology is Confirmed. The results also showed that using this method is not economical in Iran. Conclusion: According to the revealed evidences and also cost analysis, due to shortage of necessary substructures and economical aspect, installing the off-site sterilization health technology in hospitals is not possible currently. But this method can be used to provide sterilization services for clinics and outpatients centers. PMID:27390714

  3. Production of a sterile species: Quantum kinetics

    SciTech Connect

    Ho, Chiu Man; Boyanovsky, D.; Ho, C.M.

    2007-04-23

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is tau(dec)=2/Gamma(aa), but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Gamma(1)=Gamma(aa)cos^2theta(m); Gamma(2)=Gamma(aa)sin^2theta(m) where Gamma(aa) is the interaction rate of the active species in the absence of mixing and theta(m) the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the"polarization vector" and show their equivalence to those obtained from the quantum master equation and effective action.

  4. Is cosmology compatible with sterile neutrinos?

    SciTech Connect

    Dodelson, Scott; Melchiorri, Alessandro; Slosar, Anze; /Ljubljana U.

    2005-11-01

    By combining data from cosmic microwave background (CMB) experiments (including the recent BOOMERANG-2K2 results), large scale structure (LSS) and Lyman-{alpha} forest observations, we constrain the hypothesis of a fourth, sterile, massive neutrino. For the 3 massless + 1 massive neutrino case we bound the mass of the sterile neutrino to m{sub s} < 0.55eV at 95% c.l.. These results exclude at high significance the sterile neutrino hypothesis as an explanation of the LSND anomaly. We then generalize the analysis to account for active neutrino masses (which tightens the limit to m{sub s} < 0.51eV) and the possibility that the sterile abundance is not thermal. In the latter case, the constraints in the (mass, density) plane are non-trivial. For a mass of > 1eV or < 0.05eV the cosmological energy density in sterile neutrinos is always constrained to be {omega}{sub {nu}} < 0.005 at 95% c.l.. However, for a sterile neutrino mass of {approx} 0.25 eV, {omega}{sub {nu}} can be as large as 0.015.

  5. Maintaining adequate hydration and nutrition in adult enteral tube feeding.

    PubMed

    Dunn, Sasha

    2015-01-01

    Predicting the nutritional and fluid requirements of enterally-fed patients can be challenging and the practicalities of ensuring adequate delivery must be taken into consideration. Patients who are enterally fed can be more reliant on clinicians, family members and carers to meet their nutrition and hydration needs and identify any deficiencies, excesses or problems with delivery. Estimating a patient's requirements can be challenging due to the limitations of using predictive equations in the clinical setting. Close monitoring by all those involved in the patient's care, as well as regular review by a dietitian, is therefore required to balance the delivery of adequate feed and fluids to meet each patient's individual needs and prevent the complications of malnutrition and dehydration. Increasing the awareness of the signs of malnutrition and dehydration in patients receiving enteral tube feeding among those involved in a patient's care will help any deficiencies to be detected early on and rectified before complications occur. PMID:26087203

  6. Assessing juvenile sex offenders to determine adequate levels of supervision.

    PubMed

    Gerdes, K E; Gourley, M M; Cash, M C

    1995-08-01

    The present study analyzed the internal consistency of four inventories currently being used by probation officers in the state of Utah to determine adequate and efficacious supervision levels and placement for juvenile sex offenders. The internal consistency or reliability of the inventories ranged from moderate to good. Factor analysis was utilized to significantly increase the reliability of the four inventories by collapsing them into the following three factors: (a) Custodian's and Juvenile's Attitude Toward Intervention; (b) Offense Characteristics; and (c) Historical Risk Factors. These three inventories/factors explained 41.2% of the variance in the combined inventories' scores. Suggestions are made regarding the creation of an additional inventory. "Characteristics of the Victim" to account for more of the variance. In addition, suggestions as to how these inventories can be used by probation officers to make objective and consistent decisions about adequate supervision levels and placement for juvenile sex offenders are discussed. PMID:7583754

  7. Sterilization techniques for biodegradable scaffolds in tissue engineering applications

    PubMed Central

    Dai, Zheng; Ronholm, Jennifer; Tian, Yiping; Sethi, Benu; Cao, Xudong

    2016-01-01

    Biodegradable scaffolds have been extensively studied due to their wide applications in biomaterials and tissue engineering. However, infections associated with in vivo use of these scaffolds by different microbiological contaminants remain to be a significant challenge. This review focuses on different sterilization techniques including heat, chemical, irradiation, and other novel sterilization techniques for various biodegradable scaffolds. Comparisons of these techniques, including their sterilization mechanisms, post-sterilization effects, and sterilization efficiencies, are discussed. PMID:27247758

  8. Heating Process in Pasteurization and not in Sterilization Decreases the Iodine Concentration of Milk

    PubMed Central

    Nazeri, Pantea; Norouzian, Mohammad Ali; Mirmiran, Parvin; Hedayati, Mehdi; Azizi, Fereidoun

    2015-01-01

    Background: Iodine is a vital component of the thyroid hormones and is required for normal growth, development, and tissue metabolism in humans and animals. Objectives: This study for the first time compares the effects of heating during pasteurization and sterilization on the iodine concentration of milk for an adequate provision of dietary iodine. Materials and Methods: This study was carried out on multiparous Holstein Friesian lactating cows. Thirty Holstein dairy cows were fed with a diet containing 10 mg of potassium iodide (KI) per kilogram dry matter of diet. Milk samples were obtained on days 4 and 2 before and again on days 2, 4, 6, and 8 after the inclusion of KI into the total mixed ration diet of the dairy cows. The milk samples were sterilized using ultra-high temperature, following which the effect of the heating process during sterilization on the cows’ iodine concentration was compared to that in the only previous documented study from Iran in which milk supplementation with KI was the same as ours. Milk in that study was pasteurized via the high-temperature short-time method, a method which involves temperatures in excess of 73°C for durations longer than 15 seconds. Results: The inclusion of KI in the diet of the dairy cows in these 2 separate experiments increased their milk iodine levels. Pasteurization decreased the iodine content of the milk (P < 0.05), while no significant difference was observed in the iodine concentration of the sterilized milk. Conclusions: The present study showed that the iodine concentration is not decreased during the heating process in sterilization, indicating that supplemented sterilized milk could be a good alternative vehicle for dietary iodine in the prevention of iodine deficiency. PMID:26587031

  9. [Surgical procedures for sterilization of the women: certainty--complications (author's transl)].

    PubMed

    Hirsch, H A

    1976-04-01

    The time (interval, postpartum, postabortum), location (uterus, mucus membrane of the oviducts, tubes), access (transcervical, transvaginal, trans-abdominal) and the actual method of sterilization for the women (surgical, electric, thermic, mechanical) can be differentiated and combined with each other in various ways. Today the usual procedure is sterilization by partial resection of the oviducts performed laparoscopically in the interval via electrocoagulation and surgically after delivery via periumbilical minilaparotomy. Laparoscopic sterilization via electrocoagulation has a rate of failure of about 1:1,000 and the mortality rate is less than 1:10,000. The most frequent complications are: hemorrhages due to injury of the larger vessels and burns in the intestine caused by the electric current. For this reason, conventional (:unipolar") electrocoagulation should be replaced by the so-called bipolar coagulation or other newer methods which avoid these complications. On the basis of the current literature, no definitive statements can be made regarding the reliability of the newer methods (silastic ring, plastic clips, thermocoagulation). An additional, although up until now purely hypothetic, advantage of the newer methods is the possibility of reversibility. With conventional electrocoagulation, the rate of reversilbility is very low. Additional alternatives are also culdotomy and minilaparotomy in the interval with the assistance of a uterus elevator. Both ways of access may be combined with various methods of sterilization. The pros and cons of the hysterectomy as a method of sterilization are still being discussed. Occasional late sequelae of sterilization such as menstrual disorders, pain and, particularly, problems related to sexual intercourse have only recently come to light. They have not yet been adequately investigated. PMID:131732

  10. Using high-temperature formaldehyde sterilization as a model for studying gaseous sterilization.

    PubMed

    Mosley, Gregg A

    2008-01-01

    This study uses the high-temperature formaldehyde sterilization system provided by the Harvey Chemiclave, manufactured by Barnstead Thermolyne Corporation (Dubuque, IA), as a model to investigate certain phenomena associated with gaseous chemical sterilization systems. Although formaldehyde sterilization presents some unique and complex system attributes, the current studies provide helpful insights into general sterilization methods by chemicals in the gaseous state. Both population recovery and fraction negative (FN) techniques were used to assay surviving populations from biological indicators of the organism Geobacillus stearothermophilus following exposure to incremental Chemiclave cycles. Models 5500 and 6000 of the Barnstead/Thermolyne Chemiclave were used in the study. Reusable instruments such as scalers, explorers, and various hinged pieces were tested in minimum versus maximum load studies. Population recovery study results demonstrated that lethality rates increase with time throughout the Chemiclave sterilization process and that there are significant variations in lethality according to load location. The population recovery data in conjunction with the FN studies and temperature data confirm that one-half the full-cycle time is not a good estimator of one-half the full-cycle lethality because lethality curves are concave downward and lethality varies by load location. This conclusion can also be applied to other types of gaseous, chemical sterilization such as ethylene oxide. The work outlined in this study was a result of investigations into the parameters affecting formaldehyde chemical vapor sterilization with the Harvey Chemiclave sterilizer. During these studies, it became apparent that results clearly depicted the effects of continued acceleration of the rate of microbial lethality, as well as variations in delivered lethality as a function of position in the sterilizer load. This publication focuses on these observations because they are

  11. The search for new sterilizing anti-tuberculosis drugs.

    PubMed

    Mitchison, Denis A

    2004-05-01

    , often with scaling up of synthesis of the molecule and preliminary studies of toxicity and animal pharmacology before tests are done for sterilizing activity. If the drug is not good at sterilizing, all of this initial work will be largely wasted as it would only have a very limited role in the treatment of MDR disease. One of the most important steps necessary is the development of rapid and simple tests to screen for sterilizing activity. Of tests currently available, none of those employing mice seem adequate, though a screen using a streptomycin dependent Mycobacterium tuberculosis seems the most hopeful. A set of in vitro tests is described. There is an urgent need to develop these tests further since the factors slowing growth are closer to those in tuberculous cavities than in mouse models. They have the advantages of simplicity and require only small amounts of a new molecule. PMID:14977529

  12. Electroporation System for Sterilizing Water

    NASA Technical Reports Server (NTRS)

    Schlager, Kenneth J.

    2005-01-01

    A prototype of an electroporation system for sterilizing wastewater or drinking water has been developed. In electroporation, applied electric fields cause transient and/or permanent changes in the porosities of living cells. Electroporation at lower field strengths can be exploited to increase the efficiency of chemical disinfection (as in chlorination). Electroporation at higher field strengths is capable of inactivating and even killing bacteria and other pathogens, without use of chemicals. Hence, electroporation is at least a partial alternative to chlorination. The transient changes that occur in micro-organisms at lower electric-field strengths include significantly increased uptake of ions and molecules. Such increased uptake makes it possible to achieve disinfection at lower doses of chemicals (e.g., chlorine or ozone) than would otherwise be needed. Lower doses translate to lower costs and reduced concentrations of such carcinogenic chemical byproducts as trichloromethane. Higher electric fields cause cell membranes to lose semipermeability and thereby become unable to function as selective osmotic barriers between the cells and the environment. This loss of function is the cause of the cell death at higher electric-field intensities. Experimental evidence does not indicate cell lysis but, rather, combined leaking of cell proteins out of the cells as well as invasion of foreign chemical compounds into the cells. The concept of electroporation is not new: it has been applied in molecular biology and genetic engineering for decades. However, the laboratory-scale electroporators used heretofore have been built around small (400-microliter) cuvettes, partly because the smallness facilitates the generation of electric fields of sufficient magnitude to cause electroporation. Moreover, most laboratory- scale electroporators have been designed for testing static water. In contrast, the treatment cell in the present system is much larger and features a flow

  13. Improving sterile male performance in support of programmes integrating the sterile insect technique against fruit flies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The Sterile Insect Technique (SIT) is being applied against fruit fly pests in many areas of the world. Currently, factories have the capacity to produce several billion sterile male insects per week and to make them available for, irradiatiation and shipment to their destinations, where the emergin...

  14. Effect of sterilization on contaminated sponges.

    PubMed

    Kuritani, R H; McDonald, N J; Sydiskis, R J

    1993-02-01

    Sponges are routinely used as a storage medium for endodontic files during clinical practice; however, very little research has been done to determine the effectiveness of sterilization procedures for these contaminated sponges. The purpose of this in vitro study was to determine the efficacy of chemical vapor sterilizers (chemiclaves), steam pressure sterilizers (autoclaves), and dry heat sterilizers on laboratory contaminated sponges. Four different types of sponges were used in this study: a black, relatively nonporous sponge; a red, semiporous stationary sponge; a blue, endodontic sponge, and a yellow, common household sponge. Natural sponges were eliminated from the study, because their large pore size made them unsuitable as a storage medium for endodontic instruments. The sponges were divided into three groups: chemiclave, autoclave, and dry heat. Five samples of each sponge type were impregnated with biological indicating strips containing spores of Bacillus stearothermophilus. Each sponge was subjected to 25 cycles of sterilization. The spore strip indicator was inserted into the sponges at 1, 5, 10, 15, 20, and 25 cycles. The spore strip was cultivated in trypticase soy broth medium solution at 55 +/- 1 degree C for 7 days. At 7 days the culture vials were read for turbidity; its presence indicating a positive culture. The samples that were subjected to chemiclaving demonstrated positive cultures of 0.00%, 0.00%, and 30.00% and those to autoclaving 3.33%, 0.00%, and 0.00% positive cultures for the black, red, and blue sponge types, respectively. None of the sponges survived dry heat sterilization. The O-Cell-O sponges become unusable when subjected to all of the sterilization methods used in this study. PMID:8509738

  15. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America

    PubMed Central

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Introduction Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Methods Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. Results A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35–13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. Conclusions The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker

  16. The 1986-87 NASA space/gravitational biology accomplishments

    NASA Technical Reports Server (NTRS)

    Halstead, Thora W. (Editor)

    1987-01-01

    This report consists of individual technical summaries of research projects of NASA's Space/Gravitational Biology program, for research conducted during the period January 1986 to April 1987. This program utilizes the unique characteristics of the space environment, particularly microgravity, as a tool to advance knowledge in the biological sciences; understanding how gravity has shaped and affected life on Earth; and understanding how the space environment affects both plant and animal species. The summaries for each project include a description of the research, a list of accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  17. The 1988-1989 NASA Space/Gravitational Biology Accomplishments

    NASA Technical Reports Server (NTRS)

    Halstead, Thora W. (Editor)

    1990-01-01

    This report consists of individual technical summaries of research projects of NASA's space/gravitational biology program, for research conducted during the period May 1988 to April 1989. This program is concerned with using the unique characteristics of the space environment, particularly microgravity, as a tool to advance knowledge in the biological sciences; understanding how gravity has shaped and affected life on Earth; and understanding how the space environment affects both plant and animal species. The summaries for each project include a description of the research, a list of the accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  18. The 1989-1990 NASA space biology accomplishments

    NASA Technical Reports Server (NTRS)

    Halstead, Thora W. (Editor)

    1991-01-01

    Individual technical summaries of research projects on NASA's Space Biology Program for research conducted during the period May 1989 to April 1990 are presented. This program is concerned with using the unique characteristics of the space environment, particularly microgravity, as a tool to advance the following: (1) knowledge in the biological sciences; (2) understanding of how gravity has shaped and affected life on the Earth; and (3) understanding of how the space environment affects both plants and animals. The summaries for each project include a description of the research, a list of accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  19. The 1985-86 NASA space/gravitational biology accomplishments

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Individual Technical summaries of research projects of NASA's Space/Gravitational Biology Program are presented. This Program is concerned with using the unique characteristics of the space environment, particularly microgravity, as a tool to advance knowledge in the biological sciences; understanding how gravity has shaped and affected life on Earth; and understanding how the space environment affects both plant and animal species. The summaries for each project include a description of the research, a listing of the accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  20. The 1987-1988 NASA space/gravitational biology accomplishments

    NASA Technical Reports Server (NTRS)

    Halstead, Thora W. (Editor)

    1988-01-01

    Individual technical summaries of research projects of the NASA Space/Gravitational Biology Program, for research conducted during the period January 1987 to April 1988 are presented. This Program is concerned with using the characteristics of the space environment, particularly microgravity, as a tool to advance knowledge in the biological sciences; understanding how gravity has shaped and affected life on earth; and understanding how the space environment affects both plant and animal species. The summaries for each project include a description of the research, a list of the accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  1. [Efficacy of the pasteur oven as sterilization equipment in dental offices].

    PubMed

    Tavares, Solange do Socorro Fonseca; de Sousa, Joaquim Tomé; Tipple, Anaclara Ferreira Veiga; e Souza, Adenícia Custódia Silva; Pimenta, Fabiana Cristina; Anders, Patricia Staciarini

    2008-03-01

    This study was aimed at assessing the efficacy of the use of the Pasteur oven as sterilization equipment in dental offices through biological monitoring. For this assessment were taken into account how adequately the material is loaded into the equipment; time/temperature used; and preventive maintenance of the oven. The data were collected in 101 dental offices in the Central District of GoiPnia, in the State of Goiás, through observation, interviews and performance of tests with biological indicator. The results showed a lack of standardization of some of the procedures recommended by the Ministry of Health for sterilization of items in the oven, and positive results of the biological test in 46 (45.5%) of the tested cycles. The intervening factors with most significance regarding sterilization problems were: absence of an accessory thermometer to control the cycles' temperature and non-observance of the time/temperature relations recommended for the sterilization cycle through dry heat. PMID:18450161

  2. Evaluation of physicochemical properties of SiO2-coated stainless steel after sterilization.

    PubMed

    Walke, Witold; Paszenda, Zbigniew; Pustelny, Tadeusz; Opilski, Zbigniew; Drewniak, Sabina; Kościelniak-Ziemniak, Magdalena; Basiaga, Marcin

    2016-06-01

    The study of most of the literature devoted to the use of coronary stents indicates that their efficiency is determined by the physicochemical properties of the implant surface. Therefore, the authors of this study suggested conditions for the formation of SiO2 layers obtained with the use of sol-gel methodology showing physicochemical properties adequate to the specific conditions of the cardio-vascular system. Previous experience of authors helped them much to optimize the coating of 316LVM steel surface with SiO2. The values of parameters that determine the usefulness of the coating in medical applications have been determined. In order to identify the phenomena taking place at the boundary of phases and to evaluate the usefulness of the proposed surface modification, taking into consideration the medical sterilization (steam or ethylene oxide (EO)), the potentiodynamic, impedance, adhesion, surface morphology and biological assessment characterizations were performed. Regardless of the usage of the sterilizing agent (steam, EO) the study showed the reduction of critical force causing layer's delamination. The research results of corrosion resistance study also confirmed a slight decrease of SiO2 barrier properties of the samples after sterilization in contact with the artificial plasma. SiO2 layers after the sterilization process did not show significant features of cytotoxicity and had no negative influence on blood cell counts, which confirmed the results of quantitative and qualitative studies. PMID:27040207

  3. Adequation of mini satellites to oceanic altimetry missions

    NASA Astrophysics Data System (ADS)

    Bellaieche, G.; Aguttes, J. P.

    1993-01-01

    Association of the mini satellite concept and oceanic altimetry missions is discussed. Mission definition and most constraining requirements (mesoscale for example) demonstrate mini satellites to be quite adequate for such missions. Progress in altimeter characteristics, orbit determination, and position reporting allow consideration of oceanic altimetry missions using low Earth orbit satellites. Satellite constellation, trace keeping and orbital period, and required payload characteristics are exposed. The mission requirements covering Sun synchronous orbit, service area, ground system, and launcher characteristics as well as constellation maintenance strategy are specified. Two options for the satellite, orbital mechanics, propulsion, onboard power and stabilizing subsystems, onboard management, satellite ground linkings, mechanical and thermal subsystems, budgets, and planning are discussed.

  4. Sterilization of Fuji pressure-sensitive film.

    PubMed

    Liggins, A B; Hardie, W R; Finlay, J B

    1994-11-01

    Fuji Prescale film is a pressure-sensitive medium which produces a characteristic pink stain on the application of pressure. Up to a saturation level, increases in pressure will produce a denser stain, thereby providing a method of determining pressures within the interface between two articulating surfaces. The relationship between the magnitude of applied pressure and the optical density of the resulting stain is non-linear; this relationship also varies with ambient temperature and humidity, in addition to load rate, and therefore requires a calibration procedure prior to use. The use of Fuji prescale film for recording interface pressures within the joint space in vivo has been widely reported; however, the object of this study was to assess the effects of sterilizing this medium, with a view to future in vivo applications. Samples of Fuji film were sterilized using a standard ethylene oxide (ETO) gas process and their subsequent pressure-recording properties were compared to a control group of samples. The 'optical-density vs pressure' relationship for the sterilized group was significantly different from that of the control group (paired Student's t-test, P < = 0.001); however, both groups provided reliable data across the same pressure-range and both exhibited an excellent degree of repeatability (coefficient of variation < 2.5%). It was concluded that Fuji film will continue to produce pressure-stains following ETO sterilization; however, the calibration of this film will only be valid if it is conducted using film from the sterilized group. PMID:7858782

  5. Quantifying dose to the reconstructed breast: Can we adequately treat?

    SciTech Connect

    Chung, Eugene; Marsh, Robin B.; Griffith, Kent A.; Moran, Jean M.; Pierce, Lori J.

    2013-04-01

    To evaluate how immediate reconstruction (IR) impacts postmastectomy radiotherapy (PMRT) dose distributions to the reconstructed breast (RB), internal mammary nodes (IMN), heart, and lungs using quantifiable dosimetric end points. 3D conformal plans were developed for 20 IR patients, 10 autologous reconstruction (AR), and 10 expander-implant (EI) reconstruction. For each reconstruction type, 5 right- and 5 left-sided reconstructions were selected. Two plans were created for each patient, 1 with RB coverage alone and 1 with RB + IMN coverage. Left-sided EI plans without IMN coverage had higher heart Dmean than left-sided AR plans (2.97 and 0.84 Gy, p = 0.03). Otherwise, results did not vary by reconstruction type and all remaining metrics were evaluated using a combined AR and EI dataset. RB coverage was adequate regardless of laterality or IMN coverage (Dmean 50.61 Gy, D95 45.76 Gy). When included, IMN Dmean and D95 were 49.57 and 40.96 Gy, respectively. Mean heart doses increased with left-sided treatment plans and IMN inclusion. Right-sided treatment plans and IMN inclusion increased mean lung V{sub 20}. Using standard field arrangements and 3D planning, we observed excellent coverage of the RB and IMN, regardless of laterality or reconstruction type. Our results demonstrate that adequate doses can be delivered to the RB with or without IMN coverage.

  6. Purchasing a cycle helmet: are retailers providing adequate advice?

    PubMed Central

    Plumridge, E.; McCool, J.; Chetwynd, J.; Langley, J. D.

    1996-01-01

    OBJECTIVES: The aim of this study was to examine the selling of cycle helmets in retail stores with particular reference to the adequacy of advice offered about the fit and securing of helmets. METHODS: All 55 retail outlets selling cycle helmets in Christchurch, New Zealand were studied by participant observation. A research entered each store as a prospective customer and requested assistance to purchase a helmet. She took detailed field notes of the ensuing encounter and these were subsequently transcribed, coded, and analysed. RESULTS: Adequate advice for helmet purchase was given in less than half of the stores. In general the sales assistants in specialist cycle shops were better informed and gave more adequate advice than those in department stores. Those who have good advice also tended to be more good advice also tended to be more active in helping with fitting the helmet. Knowledge about safety standards was apparent in one third of sales assistants. Few stores displayed information for customers about the correct fit of cycle helmets. CONCLUSIONS: These findings suggest that the advice and assistance being given to ensure that cycle helmets fit properly is often inadequate and thus the helmets may fail to fulfil their purpose in preventing injury. Consultation between retailers and policy makers is a necessary first step to improving this situation. PMID:9346053

  7. Adequate drainage system design for heap leaching structures.

    PubMed

    Majdi, Abbas; Amini, Mehdi; Nasab, Saeed Karimi

    2007-08-17

    The paper describes an optimum design of a drainage system for a heap leaching structure which has positive impacts on both mine environment and mine economics. In order to properly design a drainage system the causes of an increase in the acid level of the heap which in turn produces severe problems in the hydrometallurgy processes must be evaluated. One of the most significant negative impacts induced by an increase in the acid level within a heap structure is the increase of pore acid pressure which in turn increases the potential of a heap-slide that may endanger the mine environment. In this paper, initially the thickness of gravelly drainage layer is determined via existing empirical equations. Then by assuming that the calculated thickness is constant throughout the heap structure, an approach has been proposed to calculate the required internal diameter of the slotted polyethylene pipes which are used for auxiliary drainage purposes. In order to adequately design this diameter, the pipe's cross-sectional deformation due to stepped heap structure overburden pressure is taken into account. Finally, a design of an adequate drainage system for the heap structure 2 at Sarcheshmeh copper mine is presented and the results are compared with those calculated by exiting equations. PMID:17321044

  8. 5 CFR 720.305 - Agency accomplishment reports.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Agency accomplishment reports. 720.305 Section 720.305 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) AFFIRMATIVE EMPLOYMENT PROGRAMS Disabled Veterans Affirmative Action Program §...

  9. 5 CFR 720.305 - Agency accomplishment reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Agency accomplishment reports. 720.305 Section 720.305 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT (CONTINUED) CIVIL SERVICE REGULATIONS (CONTINUED) AFFIRMATIVE EMPLOYMENT PROGRAMS Disabled Veterans Affirmative Action Program §...

  10. FAMILY GOALS AND SOME FACTORS ASSOCIATED WITH THEIR ACCOMPLISHMENT.

    ERIC Educational Resources Information Center

    JOHNSTON, RUPERT BERNARD

    GOALS OF FARM FAMILIES WERE ANALYZED AND FACTORS ASSOCIATED WITH THEIR ACCOMPLISHMENT STUDIED. DATA ON FARM GOALS, FARM AND HOME RESOURCES, AND INCOME WERE OBTAINED FROM 112 FAMILIES IN 18 MISSISSIPPI COUNTIES, IN WHICH THERE WERE THREE DIFFERENT COUNTY EXTENSION STAFFING PLANS. GOALS WERE CLASSIFIED IN GOUPS SUCH AS HOME AND GROUNDS, HOME…

  11. 2014 Survey of States: Initiatives, Trends, and Accomplishments

    ERIC Educational Resources Information Center

    Shyyan, Vitaliy; Lazarus, Sheryl S.; Thurlow, Martha L.

    2015-01-01

    This report summarizes the fourteenth survey of states by the National Center on Educational Outcomes (NCEO) at the University of Minnesota. Results are presented for the 50 regular states and eight of the 11 unique states. The purpose of this report is to provide a snapshot of the new initiatives, trends, accomplishments, and emerging issues…

  12. Women in History--Abigail Adams: Life, Accomplishments, and Ideas

    ERIC Educational Resources Information Center

    Kenan, Sharon K.

    2008-01-01

    This article profiles the life, accomplishments, and ideas of Abigail Adams. Born in 1944, Adams lacked a formal education, but she more than made up for that shortcoming with her love of reading, especially literature, and her interests in politics and events surrounding the young colonies. Adams was supportive of the advancement of women. She…

  13. UPPER SNAKE RIVER PRIORITY BASIN ACCOMPLISHMENT PLAN, APRIL 1973

    EPA Science Inventory

    The Upper Snake Accomplishment Basin (17040104, 170402, 170501) is defined as the Idaho and Oregon portions of 2 STORET Basins, the Upper Snake Basin and the Central Snake Basin. The Basin drains approximately 62,100 square miles in Southern Idaho and Southeastern Oregon. Four ...

  14. Final report on technical work accomplished under contract NASw-2953

    NASA Technical Reports Server (NTRS)

    Fredricks, R. W.

    1977-01-01

    A report is given on the technical work accomplished in the area of plasma physics. The subjects covered are: (1) oblique whistler instabilities, (2) current-limited electron beam injection, (3) three-dimensional ion sound turbulence, (4) theoretical aspects of sounder antenna operation and (5) whistler modes in bow shock structures.

  15. 38 CFR 39.120 - Documentation of grant accomplishments.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Documentation of grant accomplishments. 39.120 Section 39.120 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) AID FOR THE ESTABLISHMENT, EXPANSION, AND IMPROVEMENT, OR OPERATION AND MAINTENANCE, OF...

  16. 38 CFR 39.120 - Documentation of grant accomplishments.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Documentation of grant accomplishments. 39.120 Section 39.120 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) AID FOR THE ESTABLISHMENT, EXPANSION, AND IMPROVEMENT, OR OPERATION AND MAINTENANCE, OF...

  17. 38 CFR 39.120 - Documentation of grant accomplishments.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Documentation of grant accomplishments. 39.120 Section 39.120 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) AID FOR THE ESTABLISHMENT, EXPANSION, AND IMPROVEMENT, OR OPERATION AND MAINTENANCE, OF...

  18. 38 CFR 39.120 - Documentation of grant accomplishments.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Documentation of grant accomplishments. 39.120 Section 39.120 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) AID TO STATES FOR ESTABLISHMENT, EXPANSION, AND IMPROVEMENT, OR OPERATION AND MAINTENANCE,...

  19. Evaluation of the efficacy and influence of the decontamination and sterilization of FBGs exposed to S. aureus and E. coli

    NASA Astrophysics Data System (ADS)

    Karam, Leandro Z.; Franco, Ana Paula G. O.; Tomazinho, Paulo; Signorini, Luciana; Carvalho, Lídia; Fernandes, Maria H.; Hecke, Mildred B.; Kalinowski, Hypolito J.

    2011-05-01

    The FBGs (Fibre Bragg Grating) are adequate sensors for measuring strain in biomedical applications. This work evaluates the efficacy of some products and processes, which are used for the decontamination and sterilization of these sensors. Fibre optic samples, partially stripped of the primary coating, were contaminated by E. coli and S. aureus and suffered decontamination processes by autoclave heating, immersion in ethylene oxide, sodium hypochlorite, chloramine T or peracetic acid and illumination ultra-violet radiation. After each process fibre samples were removed, washed in sterile saline and placed individually in BHI broth tubes. Tubes that showed turbidity of the BHI broth were considered positive. The sterilization practices by heating and immersionand avoided the formation of bacteria colonies, whereas illumination processes were not effective to avoid the bacteria colony growth.

  20. Dynamic sterilization of titanium implants with ultraviolet light.

    PubMed

    Singh, S; Schaaf, N G

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to "dynamic sterilization" by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility. PMID:2599585

  1. Light sterile neutrinos in the early universe

    SciTech Connect

    Lunardini, Cecilia

    2014-06-24

    Cosmological and terrestrial data suggests the number of light neutrinos may be greater than 3, motivating a careful reexamination of cosmological bounds on extra light species. Big bang nucleosynthesis constrains the number of relativistic neutrino species present during nucleosynthesis, N{sub eff}{sup BBN}, while measurements of the cosmic microwave background (CMB) angular power spectrum constrain the effective energy density in relativistic neutrinos at the time of matter-radiation equality, N{sub eff}{sup CMB}. We review a scenario with two sterile neutrinos and explore whether partial thermalization of the sterile states can ease the tension between cosmological constraints on N{sub eff}{sup BBN} and terrestrial data. We conclude that, still, two additional light sterile neutrinos species cannot fit all the data at the 95% confidence level.

  2. Radiation sterilization of tissue allografts: A review.

    PubMed

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-04-28

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts. PMID:27158422

  3. Radiation sterilization of tissue allografts: A review

    PubMed Central

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-01-01

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts. PMID:27158422

  4. Sterilization and disinfection in the physician's office.

    PubMed Central

    Drummond, D C; Skidmore, A G

    1991-01-01

    OBJECTIVE: To review the principles and practice of sterilization and disinfection of medical instruments in the office setting. DATA SOURCES: Searches of MEDLINE for articles published from 1980 to 1990 on disinfection, sterilization, cross infection, surgical instruments and iatrogenic disease, bibliographies, standard texts and reference material located in a central processing department. STUDY SELECTION: We reviewed surveys of decontamination practices in physicians' offices, reviews of current recommendations for office decontamination procedures, case reports of cross infection in offices and much of the standard reference material on decontamination theory and practice. DATA SYNTHESIS: There have been few surveys of physicians' decontamination practices and few case reports of cross infection. Office practitioners have little access to practical information on sterilization and disinfection. CONCLUSION: The increasing threat of cross infection from medical instruments calls for greater knowledge about decontamination. We have adapted material from various sources and offer a primer on the subject. PMID:1913427

  5. Biological Sterilization of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Albert, F. G.; Combie, J.; Bodnar, R. J.; Hamilton, V. E.; Jolliff, B. L.; Kuebler, K.; Wang, A.; Lindstrom, D. J.; Morris, P. A.

    1999-01-01

    Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

  6. Calculating Neutrino Oscillations with Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Linehan, Bryan

    2014-09-01

    In particle physics, it is currently known that three types of neutrinos exist that interact via the weak force. Referred to as ``flavors,'' they are distinguishable and named for the lepton they produce through charged current interactions: electron, muon, and tau. In a process called neutrino oscillation, one flavor of neutrino can change into another flavor as it propagates through space. At the moment, mild discrepancies between expected and measured neutrino oscillations suggest that more types of neutrinos that do not interact via the weak force exist: sterile neutrinos. The goal of this project was to calculate non-sterile flavor oscillation probabilities when 1, 2 or 3 sterile neutrinos were assumed to exist. An application has been written in Mathematica that calculates these probabilities with the neutrino masses, linear relationships between mass and flavor states, values of CP symmetry violating constants, and constant densities of media in which the neutrinos propagate set as parameters. The application was published online for researchers to use as a tool when considering the existence of sterile neutrinos. In the immediate future, the insights this application gives into neutrino oscillations will be studied and reported. In particle physics, it is currently known that three types of neutrinos exist that interact via the weak force. Referred to as ``flavors,'' they are distinguishable and named for the lepton they produce through charged current interactions: electron, muon, and tau. In a process called neutrino oscillation, one flavor of neutrino can change into another flavor as it propagates through space. At the moment, mild discrepancies between expected and measured neutrino oscillations suggest that more types of neutrinos that do not interact via the weak force exist: sterile neutrinos. The goal of this project was to calculate non-sterile flavor oscillation probabilities when 1, 2 or 3 sterile neutrinos were assumed to exist. An application

  7. STERILIZED in the Name of Public Health

    PubMed Central

    Stern, Alexandra Minna

    2005-01-01

    In exploring the history of involuntary sterilization in California, I connect the approximately 20 000 operations performed on patients in state institutions between 1909 and 1979 to the federally funded procedures carried out at a Los Angeles County hospital in the early 1970s. Highlighting the confluence of factors that facilitated widespread sterilization abuse in the early 1970s, I trace prosterilization arguments predicated on the protection of public health. This historical overview raises important questions about the legacy of eugenics in contemporary California and relates the past to recent developments in health care delivery and genetic screening. PMID:15983269

  8. Decontamination formulations for disinfection and sterilization

    DOEpatents

    Tucker, Mark D.; Engler, Daniel E.

    2007-09-18

    Aqueous decontamination formulations that neutralize biological pathogens for disinfection and sterilization applications. Examples of suitable applications include disinfection of food processing equipment, disinfection of areas containing livestock, mold remediation, sterilization of medical instruments and direct disinfection of food surfaces, such as beef carcasses. The formulations include at least one reactive compound, bleaching activator, inorganic base, and water. The formulations can be packaged as a two-part kit system, and can have a pH value in the range of 7-8.

  9. Low temperature steam and formaldehyde sterilization.

    PubMed

    Robertshaw, R G

    1983-09-01

    A standard low temperature steam/formaldehyde autoclave was tested according to the manufacturer's instructions, using a range of test pieces containing Bacillus stearothermophilus spores as the challenge organism. There were failures in killing the challenge organism and the reasons for these are discussed. A description of modifications made to the autoclave is given together with details of an improved operating cycle. The performance of the modified autoclave was greatly improved and conditions were established for reliable and consistent sterilization of all the test pieces. A commercially produced prototype autoclave similarly modified also showed effective sterilization. PMID:6195245

  10. Sterilization of Cotton Fabrics Using Plasma Treatment

    NASA Astrophysics Data System (ADS)

    Shahidi, S.; Ghoranneviss, M.

    2013-10-01

    Microbial contamination induces surface deformations and strength degradation of cotton fabrics by invading deeply into the fibers. In this study, the sterilization effects of low pressure plasmas on bacteria-inoculated cotton fabrics were investigated. Oxygen plasma treatment completely sterilized the cotton fabrics inoculated with various concentrations of staphylococcus aureus. Also, the influence of plasma treatment on physical properties of fabrics was examined. It was found that the plasma treatment did not affect ultimate tensile strength and surface morphology of the fabrics because it took advantage of relatively low plasma temperature.

  11. Are PPS payments adequate? Issues for updating and assessing rates

    PubMed Central

    Sheingold, Steven H.; Richter, Elizabeth

    1992-01-01

    Declining operating margins under Medicare's prospective payment system (PPS) have focused attention on the adequacy of payment rates. The question of whether annual updates to the rates have been too low or cost increases too high has become important. In this article we discuss issues relevant to updating PPS rates and judging their adequacy. We describe a modification to the current framework for recommending annual update factors. This framework is then used to retrospectively assess PPS payment and cost growth since 1985. The preliminary results suggest that current rates are more than adequate to support the cost of efficient care. Also discussed are why using financial margins to evaluate rates is problematic and alternative methods that might be employed. PMID:10127450

  12. Effects of sterilization on wear in total knee arthroplasty.

    PubMed

    White, S E; Paxson, R D; Tanner, M G; Whiteside, L A

    1996-10-01

    Twenty-nine Ortholoc II ultrahigh molecular weight polyethylene tibial components were retrieved from 27 patients at revision surgery from the same hospital. The polyethylene material grade, method of sterilization, and sterilization dosage for 26 of the tibial components were determined by tracing the material lot number for each component. Each tibial surface was scored for wear using a qualitative scoring system that evaluated delamination, pitting, scratching, cold flow, abrasion, and burnishing. After the wear score analysis, 14 of the 26 components were analyzed to determine the physical and mechanical properties of the polyethylene including toughness and elongation. Seven of these 14 components were sterilized using ethylene oxide and 7 were sterilized using gamma radiation. Tibial components sterilized with gamma radiation had significantly higher wear rates than those sterilized with ethylene oxide. Thirteen of the 18 components sterilized with gamma radiation had delamination of the articular surface compared with 2 of 8 components sterilized with ethylene oxide. Mechanical properties were significantly affected by the sterilization method. Components sterilized with ethylene oxide had significantly higher toughness and percent elongation than those sterilized with gamma radiation. These findings suggest that ethylene oxide sterilization caused less microstructural damage to the polyethylene and resulted in significantly less wear than was found in those components sterilized with gamma radiation. PMID:8895634

  13. Educational Accomplishment Audit: Past, Present, and Future. Proceedings of A National Symposium on Perspectives on Educational Accomplishment Auditing.

    ERIC Educational Resources Information Center

    Cook, Desmond L., Ed.; Stoycheff, Peter A., Ed.

    The papers comprising these proceedings discuss the nature and purpose of the Independent Educational Accomplishment Audit (IEAA), a concept born in the late 1960's to establish accountability for mandatory technical assistance programs funded by the Elementary and Secondary Education Act: (1) origins and rationale of the Independent Educational…

  14. Biological monitoring of sterilizers and sterilization failures in Norwegian dental offices in 1985 and 1996.

    PubMed

    Skaug, N; Lingaas, E; Nielsen, O; Palenik, C J

    1999-08-01

    It is essential that dental office sterilizers be regularly challenged with biological indicators (BIs) in order to prove that the test spores are being killed during sterilization. The aims of the study were to biologically monitor Norwegian dental office sterilizers and to identify factors contributing to sterilization failure. In 1985, participants received a packet containing: (i) 4 BI units; (ii) a set of instructions; (iii) a questionnaire concerning operation (including biological monitoring) of the office sterilizer(s), and (iv) a return-address envelope. In 1996, offices were sent (i) a survey which included demographic questions and inquiries concerning instrument sterilization processes; (ii) 2 sets of 3 BI units with instructions for their use on 2 different days; (iii) 1 control BI unit that was not to be processed, and (iv) a return-address envelope. Both private and public offices participated. Response rate to the 1996 study was 60%, which was 9.1% of all dental offices in Norway. Testing results indicated a 6.3% overall sterilization failure rate. Three out of 163 steam autoclaves (SAs) (1.8% of total) and 14 out of 109 dry heat (DH) ovens (12.8% of total) failed. DH ovens were over 7 times more likely to fail BI testing than were SAs (chi2, P < 0.01). Demographic or hygiene procedural factors could not be correlated to sterilization performance (chi2, P > 0.05). The failure rate for SAs (n = 216) in 1985 was almost 5 times greater than in 1996 (8.8% vs 1.8%). Improvement in sterilizer performance during the decade may be related to issuance in 1986 of Norway's 1st infection control guidelines for dentistry and greater awareness of infection control practices and/or to increases over the previous 10 years in the number of postgraduate courses offered in infection control. The current Norwegian guidelines on infection control practices in public health services, including dentistry, recommend regular biological monitoring of sterilizers without

  15. Becoming Accomplished: Concerted Cultivation among Privately Educated Young Women

    ERIC Educational Resources Information Center

    Maxwell, Claire; Aggleton, Peter

    2013-01-01

    This paper takes as its starting point the concept of concerted cultivation as coined by Annette Lareau. It examines whether a focus on concerted cultivation adequately captures the various practices observed in young women's experiences of being privately educated in four schools in one area of England. We suggest that a variety of practices of…

  16. The 1992-1993 NASA Space Biology Accomplishments

    NASA Technical Reports Server (NTRS)

    Halstead, Thora W. (Editor)

    1994-01-01

    This report consists of individual technical summaries of research projects of NASA's Space Biology Program, for research conducted during the calendar years of 1992 and 1993. This program includes both plant and animal research, and is dedicated to understanding the role of gravity and the effects of microgravity on biological processes; determining the effects of the interaction of gravity and other environmental factors on biological systems; and using the microgravity of the space environment as a tool to advance fundamental scientific knowledge in the biological sciences to improve the quality of life on Earth and contribute to NASA's goal of manned exploration of space. The summaries for each project include a description of the research, a list of the accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  17. The 1990-1991 NASA space biology accomplishments

    NASA Technical Reports Server (NTRS)

    Halstead, Thora W. (Editor)

    1993-01-01

    This report consists of individual technical summaries of research projects of NASA's Space Biology Program, for research conducted during the period May 1990 through May 1991. This program includes both plant and animal research, and is dedicated to understanding the role of gravity and other environmental factors on biological systems and to using the microgravity of the space environment as a tool to advance fundamental scientific knowledge in the biological sciences to improve the quality of life on Earth and contribute to NASA's goal of manned exploration of space. The summaries for each project include a description of the research, a list of the accomplishments, an explanation of the significance of the accomplishments, and a list of publications.

  18. FY 1995 research highlights: PNL accomplishments in OER programs

    SciTech Connect

    1995-10-01

    Pacific Northwest Laboratory (PNL) conducts fundamental and applied research in support of the US Department of Energy`s (DOE) core missions in science and technology, environmental quality, energy resources, and national security. Much of this research is funded by the program offices of DOE`s Office of Energy Research (DOE-ER), primarily the Office of Basic Energy Sciences (BES) and the Office of Health and Environmental Research (OHER), and by PNL`s Laboratory Directed Research and Development (LDRD) Program. This document is a collection of research highlights that describe PNL`s accomplishments in DOE-ER funded programs during Fiscal Year 1995. Included are accomplishments in research funded by OHER`s Analytical Technologies, Environmental Research, Health Effects, General Life Sciences, and Carbon Dioxide Research programs; BES`s Materials Science, Chemical Sciences, Engineering and Geoscience, and Applied Mathematical Sciences programs; and PNL`s LDRD Program. Summaries are given for 70 projects.

  19. Abstract and research accomplishments of University Coal Research Projects

    SciTech Connect

    1995-06-01

    The Principal Investigators of the grants supported by the University Coal Research Program were requested to submit abstracts and highlight accomplishments of their respective projects in time for distribution at a conference on June 13--14, 1995 at Tennessee State University in Nashville, Tennessee. This book is a compilation of the material received in response to that request. For convenience, the 70 grants reported in this book are stored into eight technical areas, Coal Science, Coal Surface Science, Reaction Chemistry, Advanced Process Concepts, Engineering Fundamentals and Thermodynamics, Environmental Science, high Temperature Phenomena, and Special topics. Indexes are provided for locating projects by subject, principal investigators, and contracting organizations. Each extended abstract describes project objectives, work accomplished, significance to the Fossil Energy Program, and plans for the next year.

  20. System for sterilizing objects. [cleaning space vehicle systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Wright, E. E., Jr.; Moyers, C. V. (Inventor)

    1981-01-01

    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

  1. Proper monitoring of sterilization procedures used in oral surgery.

    PubMed

    Skaug, N

    1983-06-01

    The sterilization procedures used by oral surgeons in Norway have been surveyed. In 22 of the 25 oral surgical clinics controlled, instruments were sterilized by saturated steam at 121 degrees C or 134 degrees C; 3 used a dry heat oven sterilizer; dry heat and/or gas sterilization procedures supplemented steam sterilization in 17 clinics. When these sterilization procedures were monitored with biological indicators, 5 autoclaves (challenged with B. stearothermophilus spores), 2 dry heat sterilizers (B. subtilis spores), and all the Harvey Chemiclaves tested (B. subtilis spores) did not inactivate the bacterial spores. A biological monitoring system that fulfills the valid requirements for sterilization procedures given by the national health authorities and that is reliable, convenient, economical and self-contained should be used routinely in oral surgery clinics. PMID:6411637

  2. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization. PMID:9610169

  3. The eighth NASA total quality management accomplishments report, 1990

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The eighth annual accomplishments report provides numerous examples of quality strategies that have proven effective and efficient in a time when cost reduction is critical. NASA's continuous improvement efforts can provide insight for others to succeed in their own endeavors. The report covers: top management leadership and support, strategic planning, focus on the customer, employee training and recognition, employee empowerment and teamwork, measurement and analysis, and quality assurance.

  4. Chemical Research Projects Office: Functions, accomplishments, and programs

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.

    1972-01-01

    The purpose, technical accomplishments, and related activities of the Chemical Research Project Group are outlined. Data cover efforts made to: (1) identify chemical research and technology required for solutions to problems of national urgency, synchronous with aeronautics and space effort; (2) conduct basic and applied interdisciplinary research on chemical problems in the areas of macromolecular science and fire research, and (3) provide productive liason with the engineering community and effective transfer of technology to other agencies and industry.

  5. Abstracts and research accomplishments of university coal research projects

    SciTech Connect

    Not Available

    1991-06-01

    The Principal Investigators of the grants supported by the University Coal Research Program were requested to submit abstracts and highlight accomplishments of their projects in time for distribution at a grantees conference. This book is a compilation of the material received in response to the request. Abstracts discuss the following area: coal science, coal surface science, reaction chemistry, advanced process concepts, engineering fundamentals and thermodynamics, environmental science.

  6. NGNP Process Heat Applications: Hydrogen Production Accomplishments for FY2010

    SciTech Connect

    Charles V Park

    2011-01-01

    This report summarizes FY10 accomplishments of the Next Generation Nuclear Plant (NGNP) Engineering Process Heat Applications group in support of hydrogen production technology development. This organization is responsible for systems needed to transfer high temperature heat from a high temperature gas-cooled reactor (HTGR) reactor (being developed by the INL NGNP Project) to electric power generation and to potential industrial applications including the production of hydrogen.

  7. A general review of chemical sterilization in space research.

    PubMed

    Opfell, J B

    1964-01-01

    The unsolved problems in the biology and the chemistry of chemical sterilization are legion. This discussion of them emphasizes some interesting areas for useful research. Studies in molecular biology and cancer chemotherapy have produced information which has important implications in chemical sterilization, particularly with the alkylating and the oxidizing agents. Many of these problems must be solved soon if chemical sterilization is to play the role it should in space research by providing means for effectively controlling the rate and extent of mingling of the forms of terrestrial life with those of extraterrestrial life. In space research in the United States, recent work on chemical sterilization has laid heavy emphasis on the identification and exploration of principles of engineering sciences which control sterilization effectiveness. These principles are reviewed and their significance in chemical sterilization is discussed in terms of the engineering factors involved. Among these factors are: consequence of sterilant polymerization or reaction with the object to be sterilized; criteria for chemical sterilization process effectiveness; depletion of the concentration of the sterilant by evaporation or chemical reaction, including polymerization; obstacles to the diffusion or convection of the sterilizing chemical to the immediate vicinity of the microorganisms to be destroyed; protection of the microorganisms from direct contact with the sterilant; phase behavior of the sterilant in the environment of the sterilization process; presence of water or water vapor; the nature, sources and numbers of microorganisms which survive standard chemical sterilization processes; and the length of exposure required to sterilize at each temperature. The significance of chemical sterilization to space science has been well reviewed at the previous COSPAR symposia. Because several thorough reviews of the empirical knowledge concerning the effects of chemical agents on

  8. Health and Environmental Research: summary of accomplishments. Volume 2

    SciTech Connect

    Not Available

    1986-08-01

    This is an account of some of the accomplishments of the health and environmental research program performed in national laboratories, universities, and research institutes. Both direct and indirect societal benefits emerged from the new knowledge provided by the health and environmental research program. In many cases, the private sector took this knowledge and applied it well beyond the mission of supporting the defense and energy needs of the Nation. Industrial and medical applications, for example, have in several instances provided annual savings to society of $100 million or more. The form of this presentation is, in fact, through ''snapshots'' - examples of significant, tangible accomplishments in each of the areas at certain times to illustrate the role and impact of the research program. The program's worth is not necessarily confined to such accomplishments; it extends, rather, to its ability to identify and help solve potential health and environmental problems before they become critical. This anticipatory mission has been pursued with an approach that combines applied problem solving with a commitment to fundamental research that is long-term and high-risk. The narrative of this research program concludes with a perspective of its past and a prospectus on its future.

  9. Health and Environmental Research: Summary of Accomplishments. Volume 2

    DOE R&D Accomplishments Database

    1986-08-01

    This is an account of some of the accomplishments of the health and environmental research program performed in national laboratories, universities, and research institutes. Both direct and indirect societal benefits emerged from the new knowledge provided by the health and environmental research program. In many cases, the private sector took this knowledge and applied it well beyond the mission of supporting the defense and energy needs of the Nation. Industrial and medical applications, for example, have in several instances provided annual savings to society of $100 million or more. The form of this presentation is, in fact, through "snapshots" - examples of significant, tangible accomplishments in each of the areas at certain times to illustrate the role and impact of the research program. The program's worth is not necessarily confined to such accomplishments; it extends, rather, to its ability to identify and help solve potential health and environmental problems before they become critical. This anticipatory mission has been pursued with an approach that combines applied problem solving with a commitment to fundamental research that is long-term and high-risk. The narrative of this research program concludes with a perspective of its past and a prospectus on its future.

  10. 2012 ACCOMPLISHMENTS - TRITIUM AGING STUDIES ON STAINLESS STEELS

    SciTech Connect

    Morgan, M.

    2013-01-31

    This report summarizes the research and development accomplishments during FY12 for the tritium effects on materials program. The tritium effects on materials program is designed to measure the long-term effects of tritium and its radioactive decay product, helium-3, on the structural properties of forged stainless steels which are used as the materials of construction for tritium reservoirs. The FY12 R&D accomplishments include: (1) Fabricated and Thermally-Charged 150 Forged Stainless Steel Samples with Tritium for Future Aging Studies; (2) Developed an Experimental Plan for Measuring Cracking Thresholds of Tritium-Charged-and-Aged Steels in High Pressure Hydrogen Gas; (3) Calculated Sample Tritium Contents For Laboratory Inventory Requirements and Environmental Release Estimates; (4) Published report on “Cracking Thresholds and Fracture Toughness Properties of Tritium-Charged-and-Aged Stainless Steels”; and, (5) Published report on “The Effects of Hydrogen, Tritium, and Heat Treatment on the Deformation and Fracture Toughness Properties of Stainless Steels”. These accomplishments are highlighted here and references given to additional reports for more detailed information.

  11. When Lightning Strikes Twice: Profoundly Gifted, Profoundly Accomplished.

    PubMed

    Makel, Matthew C; Kell, Harrison J; Lubinski, David; Putallaz, Martha; Benbow, Camilla P

    2016-07-01

    The educational, occupational, and creative accomplishments of the profoundly gifted participants (IQs ⩾ 160) in the Study of Mathematically Precocious Youth (SMPY) are astounding, but are they representative of equally able 12-year-olds? Duke University's Talent Identification Program (TIP) identified 259 young adolescents who were equally gifted. By age 40, their life accomplishments also were extraordinary: Thirty-seven percent had earned doctorates, 7.5% had achieved academic tenure (4.3% at research-intensive universities), and 9% held patents; many were high-level leaders in major organizations. As was the case for the SMPY sample before them, differential ability strengths predicted their contrasting and eventual developmental trajectories-even though essentially all participants possessed both mathematical and verbal reasoning abilities far superior to those of typical Ph.D. recipients. Individuals, even profoundly gifted ones, primarily do what they are best at. Differences in ability patterns, like differences in interests, guide development along different paths, but ability level, coupled with commitment, determines whether and the extent to which noteworthy accomplishments are reached if opportunity presents itself. PMID:27225220

  12. Gas plasma sterilization--application of space-age technology.

    PubMed

    Crow, S; Smith, J H

    1995-08-01

    Gas plasma sterilization is new to the healthcare field. The first such sterilizer has been manufactured by Advanced Sterilization Products (J&J, Irvine, CA). The system uses hydrogen peroxide as the substrate gas and radio frequency emissions to generate plasma. This system is a low-temperature, quick-acting process with no toxic residues. It appears that this sterilizer system holds promise in the healthcare field and could help to reduce the use of ethylene oxide. PMID:7594394

  13. Status of radiation sterilization of healthcare products in China

    NASA Astrophysics Data System (ADS)

    Zhu, Nankang; Wang, Chunlei; Teng, Weifang

    2004-09-01

    This paper describes the status of 60Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization.

  14. The sterility of hospital-prepared Soffban bandages.

    PubMed

    Wood, E V; Fenwick, H; Manning, M P; Mobbs, P

    2005-11-01

    An evaluation of the sterility of hospital-prepared Soffban bandages was undertaken. Discs of Bacillus stearothermophilus were inserted into the bandage rolls, prior to sterilization in "porous load" autoclaves. The discs were subsequently removed and placed in culture media, with growth of the organism indicating failure of sterilization. It was demonstrated that Soffban could not be sterilized reliably using standard hospital autoclave techniques. PMID:16019112

  15. Molecular analysis of cytoplasmic male sterility

    SciTech Connect

    Hanson, M.R.

    1990-01-01

    The ultimate aims of the project are to understand the molecular mechanism of the disruption in pollen development which occurs in cytoplasmic male sterile plants and to understand the control of respiratory energy flow in the higher plant cell. A mitochondrial locus termed S-pcf segregates with sterility and with an alteration in respiration in Petunia. This cloned locus contains three genes, an abnormal fused gene termed pcf, a gene for a subunit of an NADH dehydrogenase complex, and a small ribosomal subunit protein. The pcf gene is comprised of partial sequences of ATPase subunit 9, cytochrome oxidase subunit II, and an unidentified reading frame. Components of the S-Pcf locus will be introduced into the nuclear of a fertile genotype under the control of appropriate regulatory signals, and polypeptide products of introduced genes will be directed to the mitochondrion with a transit peptide. By examining transgenic plants, we can determine what elements of the locus are critical for altered respiration or sterility. Such knowledge could explain how mitochondrial DNA affects pollen development in the large number of plant species which exhibit the agronomically important trait of male sterility. 10 refs., 3 figs.

  16. Light sterile neutrinos after BICEP-2

    SciTech Connect

    Archidiacono, Maria; Hannestad, Steen; Fornengo, Nicolao; Gariazzo, Stefano; Giunti, Carlo; Laveder, Marco E-mail: fornengo@to.infn.it E-mail: giunti@to.infn.it E-mail: marco.laveder@pd.infn.it

    2014-06-01

    The recent discovery of B-modes in the polarization pattern of the Cosmic Microwave Background by the BICEP2 experiment has important implications for neutrino physics. We revisit cosmological bounds on light sterile neutrinos and show that they are compatible with all current cosmological data provided that the mass is relatively low. Using CMB data, including BICEP-2, we find an upper bound of m{sub s} < 0.85 eV (2σ Confidence Level). This bound is strengthened to 0.48 eV when HST measurements of H{sub 0} are included. However, the inclusion of SZ cluster data from the Planck mission and weak gravitational measurements from the CFHTLenS project favours a non-zero sterile neutrino mass of 0.44{sup +0.11}{sub −0.16} eV. Short baseline neutrino oscillations, on the other hand, indicate a new mass state around 1.2 eV. This mass is highly incompatible with cosmological data if the sterile neutrino is fully thermalised (Δχ{sup 2} > 10). However, if the sterile neutrino only partly thermalises it can be compatible with all current data, both cosmological and terrestrial.

  17. The Decision for Male versus Female Sterilization.

    ERIC Educational Resources Information Center

    Clark, Margaret Pruitt; And Others

    1979-01-01

    The increasing popularity of sterilization underscores the need for knowledge about couples choosing male and female procedures. This research delineates four sets of variables that may be important for the decision and examines their relationship with the choice of male or female procedure among a sample of married couples. (Author)

  18. Sterilization: A Conference and a Report.

    ERIC Educational Resources Information Center

    Dillingham, Brint

    1978-01-01

    This article continues a series on Native American sterilization, based on a conference of the National Council of Churches' Interreligious Foundation for Community Organization (IFCO). Also included are an article and a report by the American Civil Liberties Union. (Author/RTS)

  19. Perspectives: Eugenics and Sterilization in the Heartland.

    ERIC Educational Resources Information Center

    Wehmeyer, Michael L.

    2003-01-01

    Noting the Governor of Virginia's recent apology for his state's participation in eugenics, this article reviews the history of the sterilization of people with epilepsy and mental retardation in several states, and the importance of the Buck v. Bell (1927) Supreme Court decision in the promotion of eugenics. (Contains references.) (CR)

  20. Advances in Sterilization and Decontamination: a Survey

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Recent technical advances made in the field of sterilization and decontamination and their applicability to private and commercial interests are discussed. Government-sponsored programs by NASA produced the bulk of material presented in this survey. The summary of past and current research discussed is detailed to enhance an effective transfer of technology from NASA to potential users.

  1. Light sterile neutrinos: Status and perspectives

    NASA Astrophysics Data System (ADS)

    Giunti, Carlo

    2016-07-01

    The indications in favor of the existence of light sterile neutrinos at the eV scale found in short-baseline neutrino oscillation experiments is reviewed. The future perspectives of short-baseline neutrino oscillation experiments and the connections with β-decay measurements of the neutrino masses and with neutrinoless double-β decay experiments are discussed.

  2. SPAN - Terminal sterilization process analysis program

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Computer program, SPAN, measures the dry heat thermal sterilization process applied to a planetary capsule and calculates the time required for heat application, steady state conditions, and cooling. The program is based on the logarithmic survival of micro-organisms. Temperature profiles must be input on tape.

  3. SPAN C - Terminal sterilization process analysis program

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Computer program, SPAN-C, measures the dry heat thermal sterilization process applied to a planetary capsule and calculates the time required for heat application, steady state conditions, and cooling. The program is based on the logarithmic survival of micro-organisms. Temperature profiles must be input on cards.

  4. Steam sterilization of air turbine dental handpieces.

    PubMed

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem. PMID:6362319

  5. Particulate contamination of sterile syringes and needles.

    PubMed

    Taylor, S A

    1982-08-01

    Commercially available sterile needles and syringes have been examined for particulate contamination using the Hiac light blockage technique. The number of particles delivered was small compared with the total number permitted for large volume parenterals. Where syringes are used in particle counting techniques, the contribution of particles should be taken into account. PMID:6126558

  6. Diluted equilibrium sterile neutrino dark matter

    NASA Astrophysics Data System (ADS)

    Patwardhan, Amol V.; Fuller, George M.; Kishimoto, Chad T.; Kusenko, Alexander

    2015-11-01

    We present a model where sterile neutrinos with rest masses in the range ˜keV to ˜MeV can be the dark matter and be consistent with all laboratory, cosmological, and large-scale structure, as well as x-ray constraints. These sterile neutrinos are assumed to freeze out of thermal and chemical equilibrium with matter and radiation in the very early Universe, prior to an epoch of prodigious entropy generation ("dilution") from out-of-equilibrium decay of heavy particles. In this work, we consider heavy, entropy-producing particles in the ˜TeV to ˜EeV rest-mass range, possibly associated with new physics at high-energy scales. The process of dilution can give the sterile neutrinos the appropriate relic densities, but it also alters their energy spectra so that they could act like cold dark matter, despite relatively low rest masses as compared to conventional dark matter candidates. Moreover, since the model does not rely on active-sterile mixing for producing the relic density, the mixing angles can be small enough to evade current x-ray or lifetime constraints. Nevertheless, we discuss how future x-ray observations, future lepton number constraints, and future observations and sophisticated simulations of large-scale structure could, in conjunction, provide evidence for this model and/or constrain and probe its parameters.

  7. Basics of sterile compounding: aseptic processing.

    PubMed

    Akers, Michael J

    2015-01-01

    This article discusses factors that affect the assurance of sterility of an aseptic process operation and balances what is required/practiced in the pharmaceutical industry via the U.S. Food and Drug Administration and European aseptic processing guidelines and what is required/practiced in compounding pharmacies via the United States Pharmacopeia (USP) General Chapter <797>. PMID:25902628

  8. Sterilization of Microorganisms by Ozone and Ultrasound

    NASA Astrophysics Data System (ADS)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  9. Male sterility and hybrid seed production

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Sexual reproduction in angiosperms is a complex process that includes a portion of the vegetative generation and all of the sexual generation. Coordination of both female and male reproduction ontogenies must occur. An abnormality anywhere in this process may lead to sterility. Genetic (nuclear) and...

  10. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    NASA Astrophysics Data System (ADS)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  11. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  12. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine...

  13. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  14. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine...

  15. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  16. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine...

  17. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  18. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  19. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  20. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  1. Development of male-sterile lines for breeding hybrid rice

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Rice is a self-pollinated crop that depends on male-sterility for F1 hybrid seed production. As an alternative to accessing existing male-sterile lines from other hybrid breeding programs, the program in Arkansas has created its own novel male-sterile sources. These were developed out of germplasm...

  2. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for...

  3. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for...

  4. The Coercive Sterilization of Aboriginal Women in Canada

    ERIC Educational Resources Information Center

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  5. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50... GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207 Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform...

  6. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  7. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  8. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently...

  9. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently...

  10. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently...

  11. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  12. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  13. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  14. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  15. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Guaifenesin sterile powder. 522.1085 Section 522.1085 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin....

  16. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Guaifenesin sterile powder. 522.1085 Section 522.1085 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin....

  17. Suppression of Pest Lepidoptera by Releasing Partially Sterile Males

    ERIC Educational Resources Information Center

    Knipling. E. F.

    1970-01-01

    Uses population growth models to calculate the theoretical suppression of reproduction achieved by releasing irradiated male moths carrying genetic sterility factors. Shows that releasing partially sterile males should be more effective than releasing fully sterile males. Discusses the costs and advantages of applying this approach to the control…

  18. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  19. Dose Limits for Man do not Adequately Protect the Ecosystem

    SciTech Connect

    Higley, Kathryn A.; Alexakhin, Rudolf M.; McDonald, Joseph C.

    2004-08-01

    It has been known for quite some time that different organisms display differing degrees of sensitivity to the effects of ionizing radiations. Some microorganisms such as the bacterium Micrococcus radiodurans, along with many species of invertebrates, are extremely radio-resistant. Humans might be categorized as being relatively sensitive to radiation, and are a bit more resistant than some pine trees. Therefore, it could be argued that maintaining the dose limits necessary to protect humans will also result in the protection of most other species of flora and fauna. This concept is usually referred to as the anthropocentric approach. In other words, if man is protected then the environment is also adequately protected. The ecocentric approach might be stated as; the health of humans is effectively protected only when the environment is not unduly exposed to radiation. The ICRP is working on new recommendations dealing with the protection of the environment, and this debate should help to highlight a number of relevant issues concerning that topic.

  20. Adequate peritoneal dialysis: theoretical model and patient treatment.

    PubMed

    Tast, C

    1998-01-01

    The objective of this study was to evaluate the relationship between adequate PD with sufficient weekly Kt/V (2.0) and Creatinine clearance (CCR) (60l) and necessary daily dialysate volume. This recommended parameter was the result of a recent multi-centre study (CANUSA). For this there were 40 patients in our hospital examined and compared in 1996, who carried out PD for at least 8 weeks and up to 6 years. These goals (CANUSA) are easily attainable in the early treatment of many individuals with a low body surface area (BSA). With higher BSA or missing RRF (Residual Renal Function) the daily dose of dialysis must be adjusted. We found it difficult to obtain the recommended parameters and tried to find a solution to this problem. The simplest method is to increase the volume or exchange rate. The most expensive method is to change from CAPD to APD with the possibility of higher volume or exchange rates. Selection of therapy must take into consideration: 1. patient preference, 2. body mass, 3. peritoneal transport rates, 4. ability to perform therapy, 5. cost of therapy and 6. risk of peritonitis. With this information in mind, an individual prescription can be formulated and matched to the appropriate modality of PD. PMID:10392062

  1. DARHT - an `adequate` EIS: A NEPA case study

    SciTech Connect

    Webb, M.D.

    1997-08-01

    The Dual Axis Radiographic Hydrodynamic Test (DARHT) Facility Environmental Impact Statement (EIS) provides a case study that is interesting for many reasons. The EIS was prepared quickly, in the face of a lawsuit, for a project with unforeseen environmental impacts, for a facility that was deemed urgently essential to national security. Following judicial review the EIS was deemed to be {open_quotes}adequate.{close_quotes} DARHT is a facility now being built at Los Alamos National Laboratory (LANL) as part of the Department of Energy (DOE) nuclear weapons stockpile stewardship program. DARHT will be used to evaluate the safety and reliability of nuclear weapons, evaluate conventional munitions and study high-velocity impact phenomena. DARHT will be equipped with two accelerator-driven, high-intensity X-ray machines to record images of materials driven by high explosives. DARHT will be used for a variety of hydrodynamic tests, and DOE plans to conduct some dynamic experiments using plutonium at DARHT as well.

  2. Orthodontic instrument sterilization with microwave irradiation

    PubMed Central

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-01-01

    Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686

  3. Device and Container for Reheating and Sterilization

    NASA Technical Reports Server (NTRS)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  4. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    PubMed

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions. PMID:11170021

  5. On Adequate Comparisons of Antenna Phase Center Variations

    NASA Astrophysics Data System (ADS)

    Schoen, S.; Kersten, T.

    2013-12-01

    One important part for ensuring the high quality of the International GNSS Service's (IGS) products is the collection and publication of receiver - and satellite antenna phase center variations (PCV). The PCV are crucial for global and regional networks, since they introduce a global scale factor of up to 16ppb or changes in the height component with an amount of up to 10cm, respectively. Furthermore, antenna phase center variations are also important for precise orbit determination, navigation and positioning of mobile platforms, like e.g. the GOCE and GRACE gravity missions, or for the accurate Precise Point Positioning (PPP) processing. Using the EUREF Permanent Network (EPN), Baire et al. (2012) showed that individual PCV values have a significant impact on the geodetic positioning. The statements are further supported by studies of Steigenberger et al. (2013) where the impact of PCV for local-ties are analysed. Currently, there are five calibration institutions including the Institut für Erdmessung (IfE) contributing to the IGS PCV file. Different approaches like field calibrations and anechoic chamber measurements are in use. Additionally, the computation and parameterization of the PCV are completely different within the methods. Therefore, every new approach has to pass a benchmark test in order to ensure that variations of PCV values of an identical antenna obtained from different methods are as consistent as possible. Since the number of approaches to obtain these PCV values rises with the number of calibration institutions, there is the necessity for an adequate comparison concept, taking into account not only the numerical values but also stochastic information and computational issues of the determined PCVs. This is of special importance, since the majority of calibrated receiver antennas published by the IGS origin from absolute field calibrations based on the Hannover Concept, Wübbena et al. (2000). In this contribution, a concept for the adequate

  6. Improving access to adequate pain management in Taiwan.

    PubMed

    Scholten, Willem

    2015-06-01

    There is a global crisis in access to pain management in the world. WHO estimates that 4.65 billion people live in countries where medical opioid consumption is near to zero. For 2010, WHO considered a per capita consumption of 216.7 mg morphine equivalents adequate, while Taiwan had a per capita consumption of 0.05 mg morphine equivalents in 2007. In Asia, the use of opioids is sensitive because of the Opium Wars in the 19th century and for this reason, the focus of controlled substances policies has been on the prevention of diversion and dependence. However, an optimal public health outcome requires that also the beneficial aspects of these substances are acknowledged. Therefore, WHO recommends a policy based on the Principle of Balance: ensuring access for medical and scientific purposes while preventing diversion, harmful use and dependence. Furthermore, international law requires that countries ensure access to opioid analgesics for medical and scientific purposes. There is evidence that opioid analgesics for chronic pain are not associated with a major risk for developing dependence. Barriers for access can be classified in the categories of overly restrictive laws and regulations; insufficient medical training on pain management and problems related to assessment of medical needs; attitudes like an excessive fear for dependence or diversion; and economic and logistical problems. The GOPI project found many examples of such barriers in Asia. Access to opioid medicines in Taiwan can be improved by analysing the national situation and drafting a plan. The WHO policy guidelines Ensuring Balance in National Policies on Controlled Substances can be helpful for achieving this purpose, as well as international guidelines for pain treatment. PMID:26068436

  7. Space robotics: Recent accomplishments and opportunities for future research

    NASA Technical Reports Server (NTRS)

    Montgomery, Raymond C.; Buttrill, Carey S.; Dorsey, John T.; Juang, Jer-Nan; Lallman, Frederick J.; Moerder, Daniel D.; Scott, Michael A.; Troutman, Patrick; Williams, Robert L., II

    1992-01-01

    The Langley Guidance, Navigation, and Control Technical Committee (GNCTC) was one of six technical committees created in 1991 by the Chief Scientist, Dr. Michael F. Card. During the kickoff meeting Dr. Card charged the chairmen to: (1) establish a cross-Center committee; (2) support at least one workshop in a selected discipline; and (3) prepare a technical paper on recent accomplishments in the discipline and on opportunities for future research. The Guidance, Navigation, and Control Committee was formed and selected for focus on the discipline of Space robotics. This report is a summary of the committee's assessment of recent accomplishments and opportunities for future research. The report is organized as follows. First is an overview of the data sources used by the committee. Next is a description of technical needs identified by the committee followed by recent accomplishments. Opportunities for future research ends the main body of the report. It includes the primary recommendation of the committee that NASA establish a national space facility for the development of space automation and robotics, one element of which is a telerobotic research platform in space. References 1 and 2 are the proceedings of two workshops sponsored by the committee during its June 1991, through May 1992 term. The focus of the committee for the June 1992 - May 1993 term will be to further define to the recommended platform in space and to add an additional discipline which includes aircraft related GN&C issues. To the latter end members performing aircraft related research will be added to the committee. (A preliminary assessment of future opportunities in aircraft-related GN&C research has been included as appendix A.)

  8. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    PubMed

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. PMID:26336003

  9. Bounds on sterile neutrino parameters from reactor experiments

    NASA Astrophysics Data System (ADS)

    Bora, Kalpana

    2014-03-01

    In this work, we present a realistic analysis of the potential of the present-day reactor experiments Double Chooz, Daya Bay and RENO for probing the existence of sterile neutrinos. We present exclusion regions for sterile oscillation parameters and find that these experimental set-ups give significant bounds on the parameter Θee especially in the low sterile oscillation region 0.01 < Δm241 < 0.05 eV2. These bounds can add to our understanding of the sterile neutrino sector since there is still a tension in the allowed regions from different experiments for sterile parameters.

  10. Modelling releases of sterile mosquitoes with different strategies.

    PubMed

    Li, Jia; Yuan, Zhiling

    2015-01-01

    To prevent the transmissions of malaria, dengue fever, or other mosquito-borne diseases, one effective weapon is the sterile insect technique in which sterile mosquitoes are released to reduce or eradicate the wild mosquito population. To study the impact of the sterile insect technique on disease transmission, we formulate discrete-time mathematical models, based on difference equations, for the interactive dynamics of the wild and sterile mosquitoes, incorporating different strategies in releasing sterile mosquitoes. We investigate the model dynamics and compare the impact of the different release strategies. Numerical examples are given to demonstrate rich dynamical features of the models. PMID:25377433

  11. Accomplishments of the Oak Ridge National Laboratory Seed Money program

    DOE R&D Accomplishments Database

    1986-09-01

    In 1974, a modest program for funding new, innovative research was initiated at ORNL. It was called the "Seed Money" program and has become part of a larger program, called Exploratory R and D, which is being carried out at all DOE national laboratories. This report highlights 12 accomplishments of the Seed Money Program: nickel aluminide, ion implantation, laser annealing, burn meter, Legionnaires' disease, whole-body radiation counter, the ANFLOW system, genetics and molecular biology, high-voltage equipment, microcalorimeter, positron probe, and atom science. (DLC)

  12. 2008 Accomplishments for CEV Parachute Assembly System (CPAS)

    NASA Technical Reports Server (NTRS)

    Martin, Ricardo

    2009-01-01

    The Crew Exploration Vehicle (CEV) Parachute Assembly System (CPAS) project is responsible for the design, development, fabrication, qualification and delivery of the CEV parachute system to support the Orion pad/ascent flight tests and the first three orbital flight tests (including the first human mission). This article will discuss the technical and research achievements accomplished in calendar year 2008, broken into three key categories: prototype testing and analysis (also referred to as the Generation 1 design), system requirements definition and design of the flight engineering development unit, and support for the Orion vehicle flight testing (primarily Pad-Abort 1).

  13. Accomplishments of the Oak Ridge National Laboratory Seed Money program

    SciTech Connect

    Not Available

    1986-09-01

    In 1974, a modest program for funding new, innovative research was initiated at ORNL. It was called the ''Seed Money'' program and has become part of a larger program, called Exploratory R and D, which is being carried out at all DOE national laboratories. This report highlights 12 accomplishments of the Seed Money Program: nickel aluminide, ion implantation, laser annealing, burn meter, Legionnaires' disease, whole-body radiation counter, the ANFLOW system, genetics and molecular biology, high-voltage equipment, microcalorimeter, positron probe, and atom science. (DLC)

  14. Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities

    SciTech Connect

    Erickson, M.D.

    1999-01-01

    The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

  15. Sterilization of dental instruments and devices: an update.

    PubMed

    Goodman, H S; Carpenter, R D; Cox, M R

    1994-04-01

    Dental sterilization techniques have become a focus of attention as a result of disclosure of occupational HIV transmission from an infected dentist to a cluster of patients. Although there has never been a confirmed report of a patient acquiring an infectious blood-borne disease from a dental instrument or device, recommendations for universal sterilization of dental handpieces and other devices have recently been implemented. Because of the higher rate of hepatitis B virus transmissability in the dental health care environment, an upgrade in sterilization protocols may be warranted. Stringent sterilization standards are especially necessary in higher-risk institutional dental care settings. However, a high rate of dental sterilization errors has been reported and traced to operator error. Recent institutional dental sterilization policy changes have been developed to reduce the chance of sterilization error, further diminishing the risk of cross contamination. PMID:8060010

  16. The sterilization efficacy of reprocessed single use diathermy pencils.

    PubMed

    Batista Neto, Simone; Graziano, Kazuko Uchikawa; Padoveze, Maria Clara; Kawagoe, Júlia Yaeko

    2010-01-01

    In Brazil, single use diathermy pencils (SUDP) are among the most common reused devices. This study assesses the sterilization efficacy of reprocessing SUDP using two cleansing methods (manual or automated), followed by one of three of the low-temperature sterilization methods: Hydrogen Peroxide Plasma (HPP), Ethylene Oxide (ETO) or Low-Temperature Steam Formaldehyde (LTSF). The sample was composed of 360 SUDP after their first use. The probability of sterilization failure was estimated considering the number of positive microbiological results obtained by cultures of the studied devices. The overall sterilization failure probability for SUDP was 0.26. The sterilization method, which presented the lowest failure probability was the LTSF (0.01), followed by ETO (0.21) and HPP (0.56). Automated cleansing obtained a better result than manual cleansing. This trial demonstrated that the probability of sterilization in reprocessed SUDP is highly dependent on both the type of cleansing and the sterilization method applied. PMID:20428701

  17. Material Recovery and Waste Form Development FY 2015 Accomplishments Report

    SciTech Connect

    Todd, Terry Allen; Braase, Lori Ann

    2015-11-01

    The Material Recovery and Waste Form Development (MRWFD) Campaign under the U.S. Department of Energy (DOE) Fuel Cycle Technologies (FCT) Program is responsible for developing advanced separation and waste form technologies to support the various fuel cycle options defined in the DOE Nuclear Energy Research and Development Roadmap, Report to Congress, April 2010. The FY 2015 Accomplishments Report provides a highlight of the results of the research and development (R&D) efforts performed within the MRWFD Campaign in FY-14. Each section contains a high-level overview of the activities, results, technical point of contact, applicable references, and documents produced during the fiscal year. This report briefly outlines campaign management and integration activities, but primarily focuses on the many technical accomplishments made during FY-15. The campaign continued to utilize an engineering driven-science-based approach to maintain relevance and focus. There was increased emphasis on development of technologies that support near-term applications that are relevant to the current once-through fuel cycle.

  18. Accomplishing Transformative Research in a Challenging Fiscal Environment

    NASA Astrophysics Data System (ADS)

    Mitchell, E. J.; Paxton, L. J.; Bust, G.

    2014-12-01

    The shift in funding is forcing scientists to promise transformative research for a pittance. To accomplish this, researchers need to transform their methodology to include societal buy-in, use of commercial off-the-shelf (COTS) technology, and cross-discipline platform usage. As the cutting edge of research expands to view the system on the global scale with extremely fine resolution, fiscally reasonable budgets present a challenge to be met. Consider how do we measure a specific variable over 45-degrees of latitude in an isolated and hostile region of Earth - the total electron count over the South Pole? This work examines this transformative research using hosted payloads on buoys, balloons, and unmanned aerial vehicles (UAVs). We will show cutting edge research occurring simultaneous with education and public outreach, offering societal buy-in through interactive websites and student-built hosted payloads. These interactions provide a vision to the public and a new database to the scientists. The use of COTS technology and cross-discipline (oceanography and space) platforms keep the cost low. We will discuss a general methodology for accomplishing transformative research in a challenging fiscal environment through integration of COTS technology, assimilative and first principle models, and observing systems simulation experiments (OSSEs).

  19. A Sterile Robotic Mars Soil Analyzer

    NASA Technical Reports Server (NTRS)

    Levin, Gilbert V.; Miller, Joseph D.; Straat, Patricia Ann; Hoover, Richard E.

    2002-01-01

    Since the 1976 Viking Mission to Mars, follow-on efforts to resolve its controversial life detection results have been thwarted by two heretofore insurmountable difficulties: the huge expense of sterilizing the entire spacecraft to protect the integrity of life detection experiments; and the lack of a practical robotic life detection package that could produce results acceptable as unambiguous by the scientific community. We here present a method that assures sterility and the complete integrity of robotic life detection experiments, all at a negligible cost. Second, we propose a candidate set of integrated, highly sensitive experiments that we believe could produce results acceptable to the vast majority of scientists. In addition to the biology-chemistry issue, the extensively debated oxidative state of the Martian surface and other chemical and physical characteristics of the Martian soil would be determined. We present our concept for a miniaturized instrument that could carry out a number of candidate experiments to achieve the objective.

  20. Surgical sterilization of free-ranging wolves.

    PubMed Central

    Spence, C E; Kenyon, J E; Smith, D R; Hayes, R D; Baer, A M

    1999-01-01

    The objective of the study was to determine whether surgical sterilization of both males and females in wolf pairs alters basic wolf social and territorial behaviors. Wolves were located from the air by snow-tracking methods and were tranquilizer-darted from a helicopter. Surgeries were performed either in a tent at the capture site or in a heated building in a nearby village. Six vasectomies and seven uterine horn ligations were performed in January and February of 1996 and 1997. Two females died: one likely related to the capture procedure, the other of a peritonitis unrelated to the surgery. One wolf had a litter. None of the wolves have shown changes in behavioral patterns. Surgical sterilization can be effective, but other, less invasive, fertility control techniques should be investigated. PMID:10065320

  1. How well does the Chemiclave sterilize handpieces?

    PubMed

    Kolstad, R A

    1998-07-01

    Using the Food and Drug Administration's protocol for testing health care sterilizers, the author investigated the ability of chemical vapor and steam to sterilize handpieces. Five internal sites of six high-speed handpiece models and four internal positions of one low-speed handpiece model were each inoculated with 10(6) Bacillus stearothermophilus spores. Half-cycle challenges were conducted with Chemiclave models EC 5500 and 8000 (Barnstead/Thermolyne) and with two autoclaves, Tuttnauer 2540M (large chamber) (Tuttnauer USA Co., Ltd.) and Statim Cassette (SciCan USA). Experiments with spores either openly exposed or partially enclosed prove that chemical vapor is an excellent lethal agent, but strongly suggest penetration weakness [corrected]. PMID:9685763

  2. Daughters mimic sterile neutrinos (almost!) perfectly

    NASA Astrophysics Data System (ADS)

    Hasenkamp, Jasper

    2014-09-01

    Since only recently, cosmological observations are sensitive to hot dark matter (HDM) admixtures with sub-eV mass, mhdmeff < eV, that are not fully-thermalised, Δ Neff < 1. We argue that their almost automatic interpretation as a sterile neutrino species is neither from theoretical nor practical parsimony principles preferred over HDM formed by decay products (daughters) of an out-of-equilibrium particle decay. While daughters mimic sterile neutrinos in Neff and mhdmeff, there are opportunities to assess this possibility in likelihood analyses. Connecting cosmological parameters and moments of momentum distribution functions, we show that—also in the case of mass-degenerate daughters with indistinguishable main physical effects—the mimicry breaks down when the next moment, the skewness, is considered. Predicted differences of order one in the root-mean-squares of absolute momenta are too small for current sensitivities.

  3. A search for sterile neutrinos in MINOS

    SciTech Connect

    Osiecki, Thomas Henry; /Texas U.

    2007-12-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining {Delta}m{sub 23}{sup 2} and {theta}{sub 23} through the disappearance of {nu}{sub {mu}}, MINOS is able to measure {nu}{sub {mu}} {yields} {nu}{sub sterile} by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  4. Fertility following reversal of female sterilization.

    PubMed

    Rachagan, S P; Jaafar, Y

    1993-06-01

    This retrospective study presents data from 26 women who underwent a reversal of female sterilization. The intrauterine pregnancy rate and ectopic pregnancy rate were 38.5% and 7.7% respectively. The most successful site of tubal anastomosis was isthmic-isthmic anastomosis. The importance of proper patient selection and factors that affect the success rate in attempted reversals are emphasised. The importance of microsurgical approach is highlighted. PMID:8350801

  5. Sterile neutrinos in the early universe

    SciTech Connect

    Malaney, R.A. ); Fuller, G.M. . Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  6. Bone banking and sterilization of bones

    NASA Astrophysics Data System (ADS)

    Minamisawa, I.; Itoman, M.; Maehara, H.; Kobayashi, A.; Watanabe, T.

    1995-08-01

    The use of banked bone (preserved allograft bone) is various and essential, because it has numerous advantages including the relative ease in retrieval a large amount of bone material and requisite shape and size. But bone banking and allografting must be promoted under obligation to stably supply safe and high-quality bone. To avoid transferring disease perfectly, irradiation sterilization is especially recommended at the present time.

  7. Gas dynamics of ethylene oxide during sterilization

    NASA Astrophysics Data System (ADS)

    Zhu, Z.; Matthews, I. P.; Wang, C.

    1999-07-01

    This article reports a case study of the dynamics of ethylene oxide gas during sterilization using a microwave spectrometer. A diffusion equation is used to describe the processes of gas penetration, gas sorption, and chemical reactions. The three processes, although mathematically related, may be solved separately under simplified assumptions. This permits the prediction of gas penetration and sorption as well as the effect of chemical reactions upon the gas concentration for loads of differing dimensions and densities.

  8. Sterile neutrinos as subdominant warm dark matter

    SciTech Connect

    Palazzo, A.; Cumberbatch, D.; Slosar, A.; Silk, J.

    2007-11-15

    In light of recent findings which seem to disfavor a scenario with (warm) dark matter entirely constituted of sterile neutrinos produced via the Dodelson-Widrow mechanism, we investigate the constraints attainable for this mechanism by relaxing the usual hypothesis that the relic neutrino abundance must necessarily account for all of the dark matter. We first study how to reinterpret the limits attainable from x-ray nondetection and Lyman-{alpha} forest measurements in the case that sterile neutrinos constitute only a fraction f{sub s} of the total amount of dark matter. Then, assuming that sterile neutrinos are generated in the early universe solely through the Dodelson-Widrow mechanism, we show how the x-ray and Lyman-{alpha} results jointly constrain the mass-mixing parameters governing their production. Furthermore, we show how the same data allow us to set a robust upper limit f{sub s} < or approx. 0.7 at the 2{sigma} level, rejecting the case of dominant dark matter (f{sub s}=1) at the {approx}3{sigma} level.

  9. [Defective function of bioindicators for steam sterilization].

    PubMed

    Botzenhart, K; Merkt-Kinzler, M

    1990-05-01

    It can be shown, that under certain conditions commercially available indicators with Bacillus stearothermophilus and packages of native spores from soil prepared according to DIN 58 946/4 react differently to treatment in a lab-type steam sterilizer. The differences were most evident when incomplete evacuation of air had to be supposed. These results lead to the conclusion that some bioindicators are not able to show the inefficient function of steam sterilizers caused by local residuals of air. This may be caused by the properties of the selected strain, by the conditions of growth and preparation of the spores and by the culture medium used after exposition. The results of our experiments as well as the resistance of mesophilic spore forming bacilli against dry heat described by other authors make it necessary to test the resistance of bioindicators for steam sterilization not only against steam according to DIN 58946/4 but also against dry heat or mixtures of steam and air. PMID:2393488

  10. [Principles of antisepsis, disinfection and sterilization].

    PubMed

    Hernández-Navarrete, María-Jesús; Celorrio-Pascual, José-Miguel; Lapresta Moros, Carlos; Solano Bernad, Victor-Manuel

    2014-12-01

    This article aims to provide a brief review of the main concepts on which the prevention and control of infection are based. Antisepsis comprises a set of techniques aimed at the total sterilization, or at most, disinfection, removing germs that contaminate an environment. Both procedures must be preceded by an environmental cleanup in the location in which they intend to be applied. The disinfection is carried out using biocides or germicides. Antimicrobial chemicals, that have mechanisms of action and resistances very similar to antibiotics, are generating concern due to the possibility of crossing genetic information that aggravates the problem of bacterial resistance. Most biocides can act as antiseptics, and applied to skin tissue, or disinfectants on inanimate materials. The spectrum of action of germicides depends on the product itself and external controllable factors: temperature, concentration, exposure time, etc. Sterilization techniques are primarily physical, by exposing the material to steam, or sterilizing gas, using autoclaves. Major advances are the use of low temperatures with shorter exposure times, in parallel with technological advances in instrumentation in order to avoid high temperatures and high use rotations due to workload. PMID:25023372

  11. Yeast hydrolysate supplementation increases field abundance and persistence of sexually mature sterile Queensland fruit fly, Bactrocera tryoni (Froggatt).

    PubMed

    Reynolds, O L; Orchard, B A; Collins, S R; Taylor, P W

    2014-04-01

    The sterile insect technique (SIT) is a non-chemical approach used to control major pests from several insect families, including Tephritidae, and entails the mass-release of sterile insects that reduce fertility of wild populations. For SIT to succeed, released sterile males must mature and compete with wild males to mate with wild females. To reach sexual maturity, the Queensland fruit fly, Bactrocera tryoni (Froggatt) (Diptera: Tephritidae), must obtain adequate nutrition after adult emergence; however, in current SIT programs sterile B. tryoni receive a pre-release diet that lacks key nutrients required to sustain sexual development. The chief objective of this study was to determine whether pre-release yeast hydrolysate (YH) supplements affect the persistence and abundance of sexually mature sterile male B. tryoni under field conditions. Experiments were run in outdoor cages under conditions of low and high environmental stress that differed markedly in temperature and humidity, and in the field. Under low environmental stress conditions, survival of sterile B. tryoni was monitored in cages under three diet treatments: (i) sugar only, (ii) sugar plus YH or (iii) sugar plus YH for 48 h and sugar only thereafter. Under high environmental stress conditions survival of sterile B. tryoni was monitored in cages under four diet treatments: (i) white sugar only, (ii) brown sugar only, (iii) white sugar plus YH and (iv) brown sugar plus YH. In a replicated field study, we released colour-marked sterile B. tryoni from two diet regimes, YH-supplemented or YH-deprived, and monitored abundance of sexually mature males. In the low-stress cage study, there was no effect of diet, although overall females lived longer than males. In the high stress cage study, mortality was lower for YH-fed flies than YH-deprived flies and females lived longer than males. In the field, YH supplementation resulted in higher abundance of sexually mature sterile males, with 1.2 YH-fed flies

  12. Surgical sterilization: an underutilized procedure for evaluating the merits of induced sterility

    USGS Publications Warehouse

    Kennelly, James J.; Converse, Kathryn A.

    1993-01-01

    Despite more than 4 decades of effort, development of effective wildlife damage control programs based on sterilization of target species has met with limited success. This is partly due to the fact that investigators have assumed, rather than empirically tested, whether the reproductive strategies of the target populations were vulnerable to the planned treatment. Equally important, methods selected to include sterility usually involve a chemical agent that can affect sociosexual behaviors of the nuisance population. In this report, we illustrate how surgically induced sterility circumvents both problems--how the concept without the potentially confounding secondary effects of a chemical. We assessed the merits of initiating research to develop a male chemosterilant for Norway rats, red-winged blackbirds, beaver, and Canada geese by inducing sterility surgically. The infidelity of many red-winged females to their polygynous territorial male was surprising and argued against searching for a male sterilant. On the other hand, beaver and Canada goose studies confirmed previous reports that both form par-bonds and are monogamous. Both should be vulnerable to a male chemosterilant approach, and research toward this goal is justified.

  13. Sterile insect technique and F₁ sterility in the European grapevine moth, Lobesia botrana.

    PubMed

    Saour, George

    2014-01-01

    Newly emerged adults of the European grapevine moth, Lobesia botrana (Denis and Schiffermuller) (Lepidoptera: Tortricidae), were irradiated with various doses of gamma radiation and crossed to unirradiated counterparts of the opposite sex. Fecundity was decreased when unirradiated females were mated with either 300-or 350-Gy-irradiated males. Adult males that were irradiated with 400 Gy and mated with unirradiated females retained a residual fertility of 2.7%. The radiation dose at which irradiated females were found to be 100% sterile when mated with unirradiated males was 150 Gy. The inherited effects in the F1 progeny of irradiated male parents were examined at 100, 150, and 200 Gy. Fecundity and fertility of the F1 progeny of males irradiated with 150 Gy and inbred or crossed with irradiated and unirradiated moths were also recorded. A significant reduction in fertility was observed when F1 males mated with either F1 or unirradiated females. According to sterility index, F1 females who mated with F1 males had greater sterility than when F1 females were crossed to 150-Gy-irradiated males. Based upon the results of this study, 150 Gy of gamma radiation would be the optimal dose to use in a sterile insect technique and F1 sterility program against L. botrana. PMID:25373155

  14. Sterile Insect Technique and F1 Sterility in the European Grapevine Moth, Lobesia botrana

    PubMed Central

    Saour, George

    2014-01-01

    Newly emerged adults of the European grapevine moth, Lobesia botrana (Denis and Schiffermuller) (Lepidoptera: Tortricidae), were irradiated with various doses of gamma radiation and crossed to unirradiated counterparts of the opposite sex. Fecundity was decreased when unirradiated females were mated with either 300- or 350-Gy-irradiated males. Adult males that were irradiated with 400 Gy and mated with unirradiated females retained a residual fertility of 2.7%. The radiation dose at which irradiated females were found to be 100% sterile when mated with unirradiated males was 150 Gy. The inherited effects in the F1 progeny of irradiated male parents were examined at 100, 150, and 200 Gy. Fecundity and fertility of the F1 progeny of males irradiated with 150 Gy and inbred or crossed with irradiated and unirradiated moths were also recorded. A significant reduction in fertility was observed when F1 males mated with either F1 or unirradiated females. According to sterility index, F1 females who mated with F1 males had greater sterility than when F1 females were crossed to 150-Gy-irradiated males. Based upon the results of this study, 150 Gy of gamma radiation would be the optimal dose to use in a sterile insect technique and F1 sterility program against L. botrana. PMID:25373155

  15. Fiscal Year 2005 Solar Radiometry and Metrology Task Accomplishments

    SciTech Connect

    Myers, D.; Andreas, A.; Reda, I.; Gotseff, P.; Wilcox, S.; Stoffel, T.; Anderberg, M.; Kay, B.; Bowen, A.

    2005-11-01

    The National Renewable Energy Laboratory (NREL) Solar Radiometry and Metrology task provides traceable optical radiometric calibrations and measurements to photovoltaic (PV) researchers and the PV industry. Traceability of NREL solar radiometer calibrations to the World Radiometric Reference (WRR) was accomplished during Pyrheliometer Comparison at NREL in October 2004. Ten spectral and more than 200 broadband radiometers for solar measurements were calibrated this year. We measured detailed spectral distributions of the NREL and PV industry Pulsed Solar Simulators and are analyzing the influence of environmental variables on radiometer uncertainty. New systems for indoor and outdoor solar radiometer calibrations and ultraviolet (UV) spectral measurements and UV radiometer calibrations were purchased and tested. Optical metrology functions support the NREL Measurement and Characterization Task effort for ISO 17025 accreditation of NREL Solar Reference Cell Calibrations and have been integrated into the NREL quality system and audited for ISO17025 compliance.

  16. Recent Accomplishments in Laser-Photovoltaic Wireless Power Transmission

    NASA Technical Reports Server (NTRS)

    Fikes, John C.; Henley, Mark W.; Mankins, John C.; Howell, Joe T.; Fork, Richard L.; Cole, Spencer T.; Skinner, Mark

    2003-01-01

    Wireless power transmission can be accomplished over long distances using laser power sources and photovoltaic receivers. Recent research at AMOS has improved our understanding of the use of this technology for practical applications. Research by NASA, Boeing, the University of Alabama-Huntsville, the University of Colorado, Harvey Mudd College, and the Naval Postgraduate School has tested various commercial lasers and photovoltaic receiver configurations. Lasers used in testing have included gaseous argon and krypton, solid-state diodes, and fiber optic sources, at wavelengths ranging from the visible to the near infra-red. A variety of Silicon and Gallium Arsenide photovoltaic have been tested with these sources. Safe operating procedures have been established, and initial tests have been conducted in the open air at AMOS facilities. This research is progressing toward longer distance ground demonstrations of the technology and practical near-term space demonstrations.

  17. IMHEX fuel cell repeat component manufacturing continuous improvement accomplishments

    SciTech Connect

    Jakaitis, L.A.; Petraglia, V.J.; Bryson, E.S.

    1996-12-31

    M-C Power is taking a power generation technology that has been proven in the laboratory and is making it a commercially competitive product. There are many areas in which this technology required scale up and refinement to reach the market entry goals for the IMHEX{reg_sign} molten carbonate fuel cell power plant. One of the primary areas that needed to be addressed was the manufacturing of the fuel cell stack. Up to this point, the fuel cell stack and associated components were virtually hand made for each system to be tested. M-C Power has now continuously manufactured the repeat components for three 250 kW stacks. M-C Power`s manufacturing strategy integrated both evolutionary and revolutionary improvements into its comprehensive commercialization effort. M-C Power`s objectives were to analyze and continuously improve stack component manufacturing and assembly techniques consistent with established specifications and commercial scale production requirements. Evolutionary improvements are those which naturally occur as the production rates are increased and experience is gained. Examples of evolutionary (learning curve) improvements included reducing scrap rates and decreasing raw material costs by buying in large quantities. Revolutionary improvements result in significant design and process changes to meet cost and performance requirements of the market entry system. Revolutionary changes often involve identifying new methods and developing designs to accommodate the new process. Based upon our accomplishments, M-C Power was able to reduce the cost of continuously manufactured fuel cell repeat components from the first to third 250 kW stack by 63%. This paper documents the continuous improvement accomplishments realized by M-C Power during IMHEX{reg_sign} fuel cell repeat component manufacturing.

  18. Degradation of chitosan-based materials after different sterilization treatments

    NASA Astrophysics Data System (ADS)

    San Juan, A.; Montembault, A.; Gillet, D.; Say, J. P.; Rouif, S.; Bouet, T.; Royaud, I.; David, L.

    2012-02-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  19. Some aspects of the sterilization program in Malaysia.

    PubMed

    Arshat, H; Ali, J; Noor Laily Abu Bakar

    1984-06-01

    Sterilization is most often indicated when the desired family size is reached and no more children are desired. Because of technical advances and societal changes surgical sterilization is increasingly becoming the most utilized method of contraception. Since female sterilization is more common, several methods have been devised to make it safe and reliable. The traditional large abdominal incision (laparotomy) is now replaced by minilaparotomy, which is a small abdominal incision. Other techniques, such as transvaginal and trancervical approaches require no incision at all. These method permit occlusion of any part of the fallopian tube. Minilapatomy is the recommended method of female sterilization for 3rd world countries. Laparoscopic sterilization appears to be more psychologically acceptable to 3rd world women who have an inherent dread of surgery. A higher incidence of hematoma formation has been reported in puerperal laparoscopic sterilizations and the failure rate is also higher than in other methods. Other complications associated with laparoscopic sterilization include wound sepsis, surgical emphysema of the parieties and uterine perforation. Laparoscopic sterilizations can be performed under local, general, spinal or epidural anesthesia. Local and general anesthesia is the commonest. Both tubal ligations and vasectomies have been available in Malaysia since the 1960s. Laparoscopy was 1st introduced in Malaysia in the early 1970s. Several laparoscopy centers have been established in Malaysia to provide specialized family planning services. Outpatient laparoscopic sterilization is a feature of the Kuala Lumpur Specialist Center. Traditonally doctors and specialists in Malaysia received their practical training in sterilization techniques during their internship or residency. Since 1980, however, a formal training program was initiated. Because laparoscopy provides interval sterilization without major abdominal surgery, this procedure has played a major

  20. Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.

    PubMed

    Rutala, W A; Gergen, M F; Weber, D J

    1999-07-01

    This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment. PMID:10432166

  1. Condom Use among Sterilized and Non-sterilized Women in County Jail and Residential Treatment Centers

    PubMed Central

    Pruitt, Sandi L.; von Sternberg, Kirk; Velasquez, Mary M.; Mullen, Patricia Dolan

    2010-01-01

    Purpose While sterilized women do not need condoms for pregnancy prevention, they may still be at risk for sexually transmitted infections (STIs). Previous studies have shown that sterilized women have lower rates of condom use but have not controlled for the nested multilevel structure of data in which individual women have multiple partners with different STI risk factors. We address this limitation by testing the association of condom use and tubal ligation using multilevel analysis. Methods Data were obtained from a cross-sectional survey of sterilized and non-sterilized women aged 18–44 in substance abuse treatment centers or county jail. Multilevel random intercept logistic models examined the association of tubal ligation and any condom use in the 30 days prior to entry and controlled for individual- and partner- level correlates. Findings Of 484 pre-menopausal respondents without hysterectomy, 194 (40.1%) reported tubal ligation. Overall, 48.3% of all women reported any condom use. In unadjusted and adjusted analyses, sterilized women were less likely to report any condom use. Women were least likely to use condoms with their main partners and more likely to use condoms with other partners and partners with whom they trade sex for drugs or money. Women were also more likely to use condoms with partners they believed to be HIV positive. Conclusion In these high-risk settings, we found a high prevalence of women reporting tubal ligation and lower odds of condom use among these women. Condom use interventions targeting sterilized women in these settings are needed. PMID:20880718

  2. Comparative Transcriptome Analysis of Recessive Male Sterility (RGMS) in Sterile and Fertile Brassica napus Lines

    PubMed Central

    Zhao, Huiyan; Liu, Chuan; Li, Jiana; Tang, Zhanglin; Xu, Xinfu; Qiu, Xiao; Wang, Rui; Lu, Kun

    2015-01-01

    The recessive genetic male sterility (RGMS) system plays a key role in the production of hybrid varieties in self-pollinating B. napus plants, and prevents negative cytoplasmic effects. However, the complete molecular mechanism of the male sterility during male-gametogenesis in RGMS remains to be determined. To identify transcriptomic changes that occur during the transition to male sterility in RGMS, we examined the male sterile line WSLA and male fertile line WSLB, which are near-isogenic lines (NILs) differing only in the fertility trait. We evaluated the phenotypic features and sterility stage using anatomical analysis. Comparative RNA sequencing analysis revealed that 3,199 genes were differentially expressed between WSLA and WSLB. Many of these genes are mainly involved in biological processes related to flowering, including pollen tube development and growth, pollen wall assembly and modification, and pollen exine formation and pollination. The transcript profiles of 93 genes associated with pollen wall and anther development were determined by quantitative RT-PCR in different flower parts, and classified into the following three major clades: 1) up-regulated in WSLA plants; 2) down-regulated in WSLA plants; and 3) down-regulated in buds, but have a higher expression in stigmas of WSLA than in WSLB. A subset of genes associated with sporopollenin accumulation were all up-regulated in WSLA. An excess of sporopollenin results in defective pollen wall formation, which leads to male sterility in WSLA. Some of the genes identified in this study are candidates for future research, as they could provide important insight into the molecular mechanisms underlying RGMS in WSLA. PMID:26656530

  3. Comparative Transcriptome Analysis of Recessive Male Sterility (RGMS) in Sterile and Fertile Brassica napus Lines.

    PubMed

    Qu, Cunmin; Fu, Fuyou; Liu, Miao; Zhao, Huiyan; Liu, Chuan; Li, Jiana; Tang, Zhanglin; Xu, Xinfu; Qiu, Xiao; Wang, Rui; Lu, Kun

    2015-01-01

    The recessive genetic male sterility (RGMS) system plays a key role in the production of hybrid varieties in self-pollinating B. napus plants, and prevents negative cytoplasmic effects. However, the complete molecular mechanism of the male sterility during male-gametogenesis in RGMS remains to be determined. To identify transcriptomic changes that occur during the transition to male sterility in RGMS, we examined the male sterile line WSLA and male fertile line WSLB, which are near-isogenic lines (NILs) differing only in the fertility trait. We evaluated the phenotypic features and sterility stage using anatomical analysis. Comparative RNA sequencing analysis revealed that 3,199 genes were differentially expressed between WSLA and WSLB. Many of these genes are mainly involved in biological processes related to flowering, including pollen tube development and growth, pollen wall assembly and modification, and pollen exine formation and pollination. The transcript profiles of 93 genes associated with pollen wall and anther development were determined by quantitative RT-PCR in different flower parts, and classified into the following three major clades: (1) up-regulated in WSLA plants; (2) down-regulated in WSLA plants; and 3) down-regulated in buds, but have a higher expression in stigmas of WSLA than in WSLB. A subset of genes associated with sporopollenin accumulation were all up-regulated in WSLA. An excess of sporopollenin results in defective pollen wall formation, which leads to male sterility in WSLA. Some of the genes identified in this study are candidates for future research, as they could provide important insight into the molecular mechanisms underlying RGMS in WSLA. PMID:26656530

  4. Eugenic Sterilization: Medico-Legal and Sociological Aspects

    PubMed Central

    Robinson, Felipe C.; Robinson, Shirley W.; Williams, Loretta J.

    1979-01-01

    The court-ordered sterilization of a normal 18-year-old black female in North Carolina focused attention on the unfortunate impact of eugenic statutes that allow sterilization as a method of social control. The existence of these laws in many states allows misapplication and abuse of authority which, not infrequently, is directed liberally to blacks and other minority groups. Eugenic sterilization is, at this time, a legally accepted form of “medical treatment.” The justification of such sterilization is the vague concept that the presumed “mentally deficient” individual is probably a potential parent of socially inadequate offspring who would likewise be socially inadequate. Since there never has been factual substantiation of whether the sterilization of these individuals will diminish the incidence of mental retardation, it is necessary to focus attention on the concept of eugenic sterilization and point out its many fallacies. PMID:480398

  5. BEST sensitivity to O(1) eV sterile neutrino

    NASA Astrophysics Data System (ADS)

    Barinov, Vladislav; Gavrin, Vladimir; Gorbunov, Dmitry; Ibragimova, Tatiana

    2016-04-01

    Numerous anomalous results in neutrino oscillation experiments can be attributed to the interference of an ˜1 eV sterile neutrino. The Baksan Experiment on Sterile Transitions (BEST), specially designed to fully explore the Gallium anomaly, starts next year. We investigate the sensitivity of BEST in search of a sterile neutrino mixed with an electron neutrino. Then, performing the combined analysis of all the Gallium experiments (SAGE, GALLEX, BEST), we find the region in the model parameter space (sterile neutrino mass and mixing angle) which will be excluded if BEST agrees with no sterile neutrino hypothesis. For the opposite case, if BEST observes the signal as it follows from the sterile neutrino explanation of the Gallium (SAGE and GALLEX) anomaly, we show how BEST will improve upon the present estimates of the model parameters.

  6. Continuous-sterilization system that uses photosemiconductor powders.

    PubMed Central

    Matsunaga, T; Tomoda, R; Nakajima, T; Nakamura, N; Komine, T

    1988-01-01

    We report a novel photochemical sterilization system in which Escherichia coli cells were sterilized with photosemiconductor powders (titanium oxide). For sterilization that could be used in practice, it was necessary to separate the TiO2 powders from the cell suspension. Therefore, semiconductor powders were immobilized on acetylcellulose membranes. We constructed a continuous-sterilization system consisting of a TiO2-immobilized acetylcellulose membrane reactor, a mercury lamp, and a masterflex pump. As a result, under the various sterilization conditions examined, E. coli (10(2) cells per ml) was sterilized to less than 1% survival when the cell suspension flowed in this system at a mean residence time of 16.0 min under irradiation (1,800 microeinsteins/m2 per s). We found that this system was reusable. PMID:3046487

  7. An evaluation of sterilization of endodontic instruments in artificial sponges.

    PubMed

    Vélez, A E; Thomas, D D; del Río, C E

    1998-01-01

    The ability to sterilize endodontic files inserted into synthetic sponges was tested. Sponges were subjected to 5 cycles of either dry heat (Driclave) or steam under pressure (autoclave) sterilization. Sterilization was corroborated by microbiological tests. The sponges and files were pre-sterilized separately using steam under pressure. One hundred eighty files contaminated with Bacillus stearothermophilus spores (experimental and positive control) and 60 noncontaminated files (negative control), were inserted into 60 sponges. After each cycle, each file and a portion of sponge surrounding the file were transferred aseptically to tubes containing trypticase soy broth culture medium for bacteriological analysis. None of the tubes containing files and portions of sponges that were subjected to autoclave grew Bacillus stearothermophilus spores. Two of 60 (3.33%) of the tubes that were subjected to sterilization by Driclave demonstrated bacterial growth. Although the sponges tolerated the dry heat cycles well physically, sterilization was achieved in only 96.67% of the cases. PMID:9487869

  8. Social and psychological perspectives on voluntary sterilization: a review.

    PubMed

    Philliber, S G; Philliber, W W

    1985-01-01

    This paper reviews social science research on the antecedents and consequences of voluntary sterilization. The major conclusions are that socioeconomic status has little impact on the decision to be sterilized and that sterilizations are rare among those without sons and among male non-whites. Significant others are important sources of encouragement and information, and good marital relations increase the likelihood of having the procedure performed. Most acceptors experience no change in sexual activity, quality of marital relationships, or work-related behavior, and few regret their choice. Negative consequences are more likely among those in India, those coerced into having a sterilization, those who did not understand the consequences of the procedure, those with health complications after sterilization, and those couples who have unstable marriages or who disagree about sterilization. PMID:3983979

  9. EarthScope Education and Outreach: Accomplishments and Emerging Opportunities

    NASA Astrophysics Data System (ADS)

    Robinson, S.; Ellins, K. K.; Semken, S. C.; Arrowsmith, R.

    2014-12-01

    EarthScope's Education and Outreach (E&O) program aims to increase public awareness of Earth science and enhance geoscience education at the K-12 and college level. The program is distinctive among major geoscience programs in two ways. First, planning for education and public engagement occurred in tandem with planning for the science mission. Second, the NSF EarthScope program includes funding support for education and outreach. In this presentation, we highlight key examples of the program's accomplishments and identify emerging E&O opportunities. E&O efforts have been collaboratively led by the EarthScope National Office (ESNO), IRIS, UNAVCO, the EarthScope Education and Outreach Subcommittee (EEOSC) and PI-driven EarthScope projects. Efforts by the EEOSC, guided by an EarthScope Education and Outreach Implementation Plan that is periodically updated, focus EarthScope E&O. EarthScope demonstrated early success in engaging undergraduate students (and teachers) in its mission through their involvement in siting USArray across the contiguous U.S. Funded E&O programs such as TOTLE, Illinois EarthScope, CEETEP (for K-12), InTeGrate and GETSI (for undergraduates) foster use of freely available EarthScope data and research findings. The Next Generation Science Standards, which stress science and engineering practices, offer an opportunity for alignment with existing EarthScope K-12 educational resources, and the EEOSC recommends focusing efforts on this task. The EEOSC recognizes the rapidly growing use of mobile smart devices by the public and in formal classrooms, which bring new opportunities to connect with the public and students. This will capitalize on EarthScope's already prominent social media presence, an effort that developed to accomplish one of the primary goals of the EarthScope E&O Implementation Plan to "Create a high-profile public identity for EarthScope" and to "Promote science literacy and understanding of EarthScope among all audiences through

  10. Cross-omics comparison of stress responses in mesothelial cells exposed to heat- versus filter-sterilized peritoneal dialysis fluids.

    PubMed

    Kratochwill, Klaus; Bender, Thorsten O; Lichtenauer, Anton M; Herzog, Rebecca; Tarantino, Silvia; Bialas, Katarzyna; Jörres, Achim; Aufricht, Christoph

    2015-01-01

    Recent research suggests that cytoprotective responses, such as expression of heat-shock proteins, might be inadequately induced in mesothelial cells by heat-sterilized peritoneal dialysis (PD) fluids. This study compares transcriptome data and multiple protein expression profiles for providing new insight into regulatory mechanisms. Two-dimensional difference gel electrophoresis (2D-DIGE) based proteomics and topic defined gene expression microarray-based transcriptomics techniques were used to evaluate stress responses in human omental peritoneal mesothelial cells in response to heat- or filter-sterilized PD fluids. Data from selected heat-shock proteins were validated by 2D western-blot analysis. Comparison of proteomics and transcriptomics data discriminated differentially regulated protein abundance into groups depending on correlating or noncorrelating transcripts. Inadequate abundance of several heat-shock proteins following exposure to heat-sterilized PD fluids is not reflected on the mRNA level indicating interference beyond transcriptional regulation. For the first time, this study describes evidence for posttranscriptional inadequacy of heat-shock protein expression by heat-sterilized PD fluids as a novel cytotoxic property. Cross-omics technologies introduce a novel way of understanding PDF bioincompatibility and searching for new interventions to reestablish adequate cytoprotective responses. PMID:26495307

  11. Sterile neutrinos in the light of IceCube

    NASA Astrophysics Data System (ADS)

    Lindner, Manfred; Rodejohann, Werner; Xu, Xun-Jie

    2016-01-01

    We determine constraints on parameters of a single eV-scale light neutrino using IceCube-59 data. Particular emphasis is put on the question whether such an analysis can rule out sterile neutrino hints. While important complementary information is provided, the different dependence on the various sterile neutrino mixing angles makes it currently not possible to fully exclude short baseline appearance results or sterile neutrinos in general.

  12. Microwave sterilization of Candida on underwear fabric. A preliminary report

    SciTech Connect

    Friedrich, E.G. Jr.; Phillips, L.E.

    1988-05-01

    Candida-contaminated underwear might not be sterilized by ordinary laundering. The effectiveness of microwaving against Candida albicans on fabric was therefore determined. Swatches of Candida-impregnated cotton underpants fabric were subjected to domestic microwaving at the high setting for up to 30 minutes. If the fabric was microwaved dry, the Candida organisms survived. If the fabric was moistened, sterilization occurred within five minutes. Microwaving wet, freshly laundered cotton underpants should sterilize residual Candida and reduce the risk of reinfection.

  13. Testing a steam-formaldehyde sterilizer for gas penetration efficiency

    PubMed Central

    Line, Stuart J.; Pickerill, J. K.

    1973-01-01

    A test piece is described for monitoring the performance of low-temperature steam-with-formaldehyde sterilizers. Comparative tests have shown it to be more difficult to penetrate than an arterial catheter when exposed to the same sterilizing conditions. It is permanent and simple to use and maintain. The growth or non-growth of bacterial spores, in the convenient form of spore strips, is used to indicate the efficacy of sterilization. PMID:4752414

  14. Plant's sterilization rule for fertile women cited.

    PubMed

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs. PMID:12336913

  15. Percentage of Adults with High Blood Pressure Whose Hypertension Is Adequately Controlled

    MedlinePlus

    ... is Adequately Controlled Percentage of Adults with High Blood Pressure Whose Hypertension is Adequately Controlled Heart disease ... Survey. Age Group Percentage of People with High Blood Pressure that is Controlled by Age Group f94q- ...

  16. System and method of applying energetic ions for sterilization

    DOEpatents

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and across the cold plasma, is provided.

  17. Self-interacting dark matter and sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Tang, Yong

    2016-05-01

    We discuss some possible astrophysical and cosmological connections between dark matter and sterile neutrinos. Both the controversies at small scales for traditional cold dark matter (CDM) and anomalies in neutrino experiments seem to suggest that there might be new self-interactions for dark matter and sterile neutrinos. Surprisingly, if the new interaction also mediates between dark matter and sterile neutrinos, “missing satellite problem” in CDM paradigm can also be solved. On the other hand, light sterile neutrinos with self-interacting can also satisfy the cosmological bounds.

  18. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    PubMed

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa. PMID:25893387

  19. Assessment of the effectiveness of dental sterilizers using biological monitors.

    PubMed

    McErlane, B; Rosebush, W J; Waterfield, J D

    1992-06-01

    This study was undertaken to evaluate the effectiveness of steam, chemical vapor, and dry heat sterilizers, over a three-year period, in dental operatories subscribing to the University of British Columbia's sterilization monitoring service. A total of 4,579 sterilizer loads were tested. The results demonstrated an overall failure rate of 4.4 per cent. Individual failure rates for each type of sterilizer were: chemiclaves, 4.9 per cent; steam autoclaves, 2.3 per cent; and dry heat ovens, 7.9 per cent. In 38 per cent of these cases, the reasons for failure could be attributed to a definite cause. PMID:1633580

  20. End-preparation assessments and tests for compounded sterile preparations.

    PubMed

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests. PMID:24261146

  1. The Vasimr Engine: Project Status and Recent Accomplishments

    NASA Technical Reports Server (NTRS)

    ChangDiaz, Franklin R.; Squire, Jared P.; Bering, Edgar A., III; Baitty, F. Wally; Goulding, Richard H.; Bengtson, Roger D.

    2004-01-01

    The development of the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) was initiated in the late 1970s to address a critical requirement for fast, high-power interplanetary space transportation. While not being a fusion rocket, it nevertheless borrows heavily from that technology and takes advantage of the natural topology of open-ended magnetic systems. In addition to its high power density and high exhaust velocity, VASIMR is capable of "constant power throttling" a feature, which allows in-flight mission-optimization of thrust and specific impulse to enhance performance and reduce trip time. A NASA-led, research team, involving industry, academia and government facilities is pursuing the development of this concept in the United States. The technology can be validated, in the near term, in venues such as the International Space Station, where it can also serve as both a drag compensation device and a plasma contactor for the orbital facility. Other near-Earth applications in the commercial and scientific satellite sectors are also envisioned. This presentation covers the evolution of the VASIMR concept to its present status, as well as recent accomplishments in our understanding of the physics. Approaches and collaborative programs addressing the major technical challenges will also be presented.

  2. Fort Collins Science Center: Fiscal Year 2007 Accomplishments

    USGS Publications Warehouse

    Wilson, J.T.

    2008-01-01

    In Fiscal Year 2007 (FY07), the U.S. Geological Survey (USGS) Fort Collins Science Center (FORT) continued research vital to U.S. Department of the Interior science and management needs and associated USGS programmatic goals. FORT work also supported the science needs of other government agencies as well as private cooperators. Specifically, FORT scientific research and technical assistance focused on client and partner needs and goals in the areas of biological information management, fisheries and aquatic systems, invasive species, status and trends of biological resources, terrestrial ecosystems, and wildlife resources. In addition, FORT's 5-year strategic plan was refined to incorporate focus areas identified in the USGS strategic science plan, including ecosystem-landscape analysis, global climate change, and energy and mineral resource development. As a consequence, several science projects initiated in FY07 were either entirely new research dor amplifications of existing work. Highlights of FORT project accomplishments are described below under the USGS science program with which each task is most closely associated. The work of FORT's 6 branches (Aquatic Systems and Technology Applications, Ecosystem Dynamics, Information Science, Invasive Species Science, Policy Analysis and Science Assistance, and Species and Habitats of Federal Interest) often involves major partnerships with other agencies or cooperation with other USGS disciplines (Geology, Geography, Water Resources) and the Geospatial Information Office.

  3. National Climate Change and Wildlife Science Center project accomplishments: highlights

    USGS Publications Warehouse

    Holl, Sally

    2011-01-01

    The National Climate Change and Wildlife Science Center (NCCWSC) has invested more than $20M since 2008 to put cutting-edge climate science research in the hands of resource managers across the Nation. With NCCWSC support, more than 25 cooperative research initiatives led by U.S. Geological Survey (USGS) researchers and technical staff are advancing our understanding of habitats and species to provide guidance to managers in the face of a changing climate. Projects focus on quantifying and predicting interactions between climate, habitats, species, and other natural resources such as water. Spatial scales of the projects range from the continent of North America, to a regional scale such as the Pacific Northwest United States, to a landscape scale such as the Florida Everglades. Time scales range from the outset of the 20th century to the end of the 21st century. Projects often lead to workshops, presentations, publications and the creation of new websites, computer models, and data visualization tools. Partnership-building is also a key focus of the NCCWSC-supported projects. New and on-going cooperative partnerships have been forged and strengthened with resource managers and scientists at Federal, tribal, state, local, academic, and non-governmental organizations. USGS scientists work closely with resource managers to produce timely and relevant results that can assist managers and policy makers in current resource management decisions. This fact sheet highlights accomplishments of five NCCWSC projects.

  4. The Mixed Waste Focus Area: Status and accomplishments

    SciTech Connect

    Conner, J.E.; Williams, R.E.

    1997-08-01

    The Mixed Waste Focus Area began operations in February of 1995. Its mission is to provide acceptable technologies that enable implementation of mixed waste treatment systems developed in partnership with end-users, stakeholders, tribal governments, and regulators. The MWFA will develop, demonstrate, and deliver implementable technologies for treatment of mixed waste within the DOE complex. Treatment refers to all post waste-generation activities including sampling and analysis, characterization, storage, processing, packaging, transportation, and disposal. The MWFA`s mission arises from the Resources Conservation and Recovery Act (RCRA) as amended by the Federal Facility Compliance Act. Each DOE site facility that generates or stores mixed waste prepared a plan, the Site Treatment Plan, for developing treatment capacities and treating that waste. Agreements for each site were concluded with state regulators, resulting in Consent Orders providing enforceable milestones for achieving treatment of the waste. The paper discusses the implementation of the program, its status, accomplishments and goals for FY1996, and plans for 1997.

  5. Research accomplishments and future goals in particle physics

    NASA Astrophysics Data System (ADS)

    1994-06-01

    This proposal presents the research accomplishments and ongoing activities of Boston University researchers in high energy physics. Some changes have been made in the structure of the program from the previous arrangement of tasks. Task B, Accelerator Design Physics, is being submitted as a separate proposal for an independent grant; this will be consistent with the nature of the research and the source of funding. Boston University is active in seven principal areas: (1) Task A: Colliding Beams - physics of e(sup +)e(sup -) and (anti p)p collisions; (2) Task C: MACRO Experiment - search for magnetic monopoles and study of cosmic rays; (3) Task D: Proton Decay - search for nucleon instability and study of neutrino interactions; (4) Tasks E, J, and N: Particle Theory - theoretical high energy particle physics, including two Outstanding Junior Investigator awards; (5) Task F: Muon G-2 - measurement of the anomalous magnetic moment of the muon; (6) Task K: SSCintcal - calorimetry for the GEM Experiment; (7) Task L: Muon Detectors for the GEM Experiment. The body of the proposal is devoted to detailed discussions of each of the tasks. The total budget request for the program appears in a summary chapter that includes a general budget discussion and individual budget requests and explanations for each of the tasks.

  6. Sterile neutrinos in neutrinoless double beta decay

    SciTech Connect

    Benes, P.; Faessler, Amand; Simkovic, F.; Kovalenko, S.

    2005-04-01

    We study possible contribution of the Majorana neutrino mass eigenstate {nu}{sub h}, dominated by a sterile neutrino component, to neutrinoless double beta (0{nu}{beta}{beta}) decay. A special emphasis is made on accurate calculation of the corresponding nuclear matrix elements. From the current experimental lower bound on the 0{nu}{beta}{beta}-decay half-life of 76 Ge we derive stringent constraints on the {nu}{sub h}-{nu}{sub e} mixing in a wide region of the values of {nu}{sub h} mass. We discuss cosmological and astrophysical status of {nu}{sub h} in this mass region.

  7. Cross-cultural attitudes toward voluntary sterilization.

    PubMed

    Hong, S

    1985-06-01

    The degree to which voluntary sterilization (VS) is accepted as a form of fertility control throughout the world was assessed by examining the prevalence and legal status of VS in all countries for which information was available and by examining current religious and traditional attitudes toward VS. Information on VS prevalence for 73 countries indicates that in 28 countries, 10% of all eligible couples rely on VS. In a number of countries, including Korea, New Zealand, Panama, US, and Puerto Rico, 25% or more of all currently married women of reproductive age rely on VS. VS prevalence rates tend to be higher in Asian countries than in African, Latin American, and Middle Eastern countries. In a number of countries, the average age and family size of VS acceptors is declining. Information on the legal status of VS for 124 countries indicates that 22 countries have laws which permit or encourage VS. These countries contain 13.4% of the world's population. In 54 countries, representing 60% of the world's population, there are no laws restricting VS, and VS is generally assumed to be legal. In 29 countries, representing 14% of world's population, the legal status of VS is unclear. In the remaining 29 countries, sterilization is forbidden except for medical or eugenic reasons. The degree to which these laws actually restrict VS varies from country to country. For example in Indonesia VS is illegal but widely practiced. Although some religious teachings discourage sterilization, the impact of religion on VS varies considerably from country to country. In the Catholic countries of Panama, Dominican Republic, and Philippines the prevalence of VS is high, and in the Catholic countries of Argentina, Bolivia, and Uruguay the prevalence of VS is low. VS prevalence is generally low in Muslim countries, but high in the Muslim countries of Tunisia, Indonesia, and Bangladesh. VS prevalence is high in the Buddhist country of Thailand but low in the Buddhist country of Burma

  8. Influence Of Sterilization On Bulk And Surface Morphologies Of Copolyether-Urethane-Ureas

    NASA Astrophysics Data System (ADS)

    Knutson, K.; Lyman, D. J.

    1981-10-01

    The influence of sterilization on the bulk and surface morphologies of a copolyether-urethane-urea was studied. The bulk morphology was altered due to annealing by autoclaving and ethylene oxide sterilization. Radiation sterilization did not significantly alter the morphology. Surface morphology was not significantly altered by any of the sterilization procedures. Changes in chemical structure as the result of sterilization were not observed.

  9. Defective pollen wall contributes to male sterility in the male sterile line 1355A of cotton

    PubMed Central

    Wu, Yuanlong; Min, Ling; Wu, Zancheng; Yang, Li; Zhu, Longfu; Yang, Xiyan; Yuan, Daojun; Guo, Xiaoping; Zhang, Xianlong

    2015-01-01

    To understand the mechanisms of male sterility in cotton (Gossypium spp.), combined histological, biochemical and transcription analysis using RNA-Seq was carried out in the anther of the single-gene recessive genic male sterility system of male sterile line 1355A and male fertile line 1355B, which are near-isogenic lines (NILs) differing only in the fertility trait. A total of 2,446 differentially expressed genes were identified between the anthers of 1355AB lines, at three different stages of development. Cluster analysis and functional assignment of differentially expressed genes revealed differences in transcription associated with pollen wall and anther development, including the metabolism of fatty acids, glucose, pectin and cellulose. Histological and biochemical analysis revealed that a major cellular defect in the 1355A was a thicker nexine, consistent with the RNA-seq data, and further gene expression studies implicated differences in fatty acids synthesis and metabolism. This study provides insight into the phenotypic characteristics and gene regulatory network of the genic male sterile line 1355A in upland cotton. PMID:26043720

  10. Evaluation of sterility and fertility of male sterile lines in the USPB farm

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Hybrid rice has proven to have a yield advantage of 15–20% over the best inbred cultivars at the commercial scale worldwide. At present, two methods have been successfully commercialized; the three-line and two-line systems. The three-line system consists of the male sterile (MS), maintainer and res...

  11. 21 CFR 514.117 - Adequate and well-controlled studies.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... production performance, or biased observation. One or more adequate and well-controlled studies are required... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Adequate and well-controlled studies. 514.117... Applications § 514.117 Adequate and well-controlled studies. (a) Purpose. The primary purpose of...

  12. 21 CFR 514.117 - Adequate and well-controlled studies.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... production performance, or biased observation. One or more adequate and well-controlled studies are required... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Adequate and well-controlled studies. 514.117... Applications § 514.117 Adequate and well-controlled studies. (a) Purpose. The primary purpose of...

  13. 21 CFR 514.117 - Adequate and well-controlled studies.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... production performance, or biased observation. One or more adequate and well-controlled studies are required... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Adequate and well-controlled studies. 514.117... Applications § 514.117 Adequate and well-controlled studies. (a) Purpose. The primary purpose of...

  14. 21 CFR 514.117 - Adequate and well-controlled studies.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... production performance, or biased observation. One or more adequate and well-controlled studies are required... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Adequate and well-controlled studies. 514.117... Applications § 514.117 Adequate and well-controlled studies. (a) Purpose. The primary purpose of...

  15. 21 CFR 514.117 - Adequate and well-controlled studies.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... production performance, or biased observation. One or more adequate and well-controlled studies are required... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Adequate and well-controlled studies. 514.117... Applications § 514.117 Adequate and well-controlled studies. (a) Purpose. The primary purpose of...

  16. 21 CFR 801.5 - Medical devices; adequate directions for use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; adequate directions for use. 801... (CONTINUED) MEDICAL DEVICES LABELING General Labeling Provisions § 801.5 Medical devices; adequate directions for use. Adequate directions for use means directions under which the layman can use a device...

  17. 21 CFR 801.5 - Medical devices; adequate directions for use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical devices; adequate directions for use. 801... (CONTINUED) MEDICAL DEVICES LABELING General Labeling Provisions § 801.5 Medical devices; adequate directions for use. Adequate directions for use means directions under which the layman can use a device...

  18. 21 CFR 801.5 - Medical devices; adequate directions for use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical devices; adequate directions for use. 801... (CONTINUED) MEDICAL DEVICES LABELING General Labeling Provisions § 801.5 Medical devices; adequate directions for use. Adequate directions for use means directions under which the layman can use a device...

  19. 21 CFR 801.5 - Medical devices; adequate directions for use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical devices; adequate directions for use. 801... (CONTINUED) MEDICAL DEVICES LABELING General Labeling Provisions § 801.5 Medical devices; adequate directions for use. Adequate directions for use means directions under which the layman can use a device...

  20. 21 CFR 801.5 - Medical devices; adequate directions for use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical devices; adequate directions for use. 801... (CONTINUED) MEDICAL DEVICES LABELING General Labeling Provisions § 801.5 Medical devices; adequate directions for use. Adequate directions for use means directions under which the layman can use a device...

  1. 76 FR 51041 - Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ... HUMAN SERVICES Food and Drug Administration Hemoglobin Standards and Maintaining Adequate Iron Stores in... Standards and Maintaining Adequate Iron Stores in Blood Donors.'' The purpose of this public workshop is to... donor safety and blood availability, and potential measures to maintain adequate iron stores in...

  2. 36 CFR 13.960 - Who determines when there is adequate snow cover?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... adequate snow cover? 13.960 Section 13.960 Parks, Forests, and Public Property NATIONAL PARK SERVICE... Preserve Snowmachine (snowmobile) Operations § 13.960 Who determines when there is adequate snow cover? The superintendent will determine when snow cover is adequate for snowmachine use. The superintendent will follow...

  3. 36 CFR 13.960 - Who determines when there is adequate snow cover?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... adequate snow cover? 13.960 Section 13.960 Parks, Forests, and Public Property NATIONAL PARK SERVICE... Preserve Snowmachine (snowmobile) Operations § 13.960 Who determines when there is adequate snow cover? The superintendent will determine when snow cover is adequate for snowmachine use. The superintendent will follow...

  4. 36 CFR 13.960 - Who determines when there is adequate snow cover?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... adequate snow cover? 13.960 Section 13.960 Parks, Forests, and Public Property NATIONAL PARK SERVICE... Preserve Snowmachine (snowmobile) Operations § 13.960 Who determines when there is adequate snow cover? The superintendent will determine when snow cover is adequate for snowmachine use. The superintendent will follow...

  5. 36 CFR 13.960 - Who determines when there is adequate snow cover?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... adequate snow cover? 13.960 Section 13.960 Parks, Forests, and Public Property NATIONAL PARK SERVICE... Preserve Snowmachine (snowmobile) Operations § 13.960 Who determines when there is adequate snow cover? The superintendent will determine when snow cover is adequate for snowmachine use. The superintendent will follow...

  6. 36 CFR 13.960 - Who determines when there is adequate snow cover?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... adequate snow cover? 13.960 Section 13.960 Parks, Forests, and Public Property NATIONAL PARK SERVICE... Preserve Snowmachine (snowmobile) Operations § 13.960 Who determines when there is adequate snow cover? The superintendent will determine when snow cover is adequate for snowmachine use. The superintendent will follow...

  7. Astrobiology at Arizona State University: An Overview of Accomplishments

    NASA Technical Reports Server (NTRS)

    Farmer, Jack

    2005-01-01

    During our five years as an NAI charter member, Arizona State University sponsored a broadly-based program of research and training in Astrobiology to address the origin, evolution and distribution of life in the Solar System. With such a large, diverse and active team, it is not possible in a reasonable space, to cover all details of progress made over the entire five years. The following paragraphs provide an overview update of the specific research areas pursued by the Arizona State University (ASU) Astrobiology team at the end of Year 5 and at the end of the 4 month and subsequent no cost month extensions. for a more detailed review, the reader is referred to the individual annual reports (and Executive Summaries) submitted to the NAI at the end of each of our five years of membership. Appended in electronic form is our complete publication record for all five years, plus a tabulation of undergraduates, graduate students and post-docs supported by our program during this time. The overarching theme of ASU s Astrobiology program was "Exploring the Living Universe: Studies of the Origin, Evolution and Distribution of Life in the Solar System". The NAi-funded research effort was organized under three basic sub- themes: 1. Origins of the Basic Building Blocks of Life. 2. Early Biosphere Evolution. and 3. Exploring for Life in the Solar System. These sub-theme areas were in turn, subdivided into Co-lead research modules. In the paragraphs that follow, accomplishments for individual research modules are briefly outlined, and the key participants presented in tabular form. As noted, publications for each module are appended in hard copy and digital formats, under the name(s) of lead co-Is.

  8. A microbiological view of sterile service production.

    PubMed

    Atfield, R D

    1991-06-01

    The primary purpose of a Sterile Services Department is the prevention of infection. A specific guide to Good Manufacturing Practice (GMP) has been published by the Institute of Sterile Service Management to assist managers to ensure that the final products are of the nature and quality intended. The testing and monitoring of machinery, such as autoclaves, has an obvious microbiological relevance but other practices, such as expire dates and presterilization of used items, are of dubious microbiological advantage and can act against the main aim. GMP recommendations on environmental controls have received disproportionate attention to the remainder of the document, particularly relating to packing rooms. The standard should not be seen as a primarily microbiological measure but as a sensible control to limit the ingress of unwanted dust, flies and people and provide basic ventilation. Tests indicate that the standard for particle counts can be achieved without structural alteration in some departments. Microbiological counts are similar to those within operating theatres and additional protective clothing is of no apparent advantage. Process failure is the main cause of risks to the patient, and other practices, although both relevant and important, should not be given a false microbiological significance as these can detract and distract attention from the main issue. PMID:1679826

  9. Targeted gene silencing to induce permanent sterility.

    PubMed

    Dissen, G A; Lomniczi, A; Boudreau, R L; Chen, Y H; Davidson, B L; Ojeda, S R

    2012-08-01

    A non-surgical method to induce sterility would be a useful tool to control feral populations of animals. Our laboratories have experience with approaches aimed at targeting brain cells in vivo with vehicles that deliver a payload of either inhibitory RNAs or genes intended to correct cellular dysfunction. A combination/modification of these methods may provide a useful framework for the design of approaches that can be used to sterilize cats and dogs. For this approach to succeed, it has to meet several conditions: it needs to target a gene essential for fertility. It must involve a method that can selectively silence the gene of interest. It also needs to deliver the silencing agent via a minimally invasive method. Finally, the silencing effect needs to be sustained for many years, so that expansion of the targeted population can be effectively prevented. In this article, we discuss this subject and provide a succinct account of our previous experience with: (i) molecular reagents able to disrupt reproductive cyclicity when delivered to regions of the brain involved in the control of reproduction and (ii) molecular reagents able to ameliorate neuronal disease when delivered systemically using a novel approach of gene therapy. PMID:22827375

  10. Daughters mimic sterile neutrinos (almost!) perfectly

    SciTech Connect

    Hasenkamp, Jasper

    2014-09-01

    Since only recently, cosmological observations are sensitive to hot dark matter (HDM) admixtures with sub-eV mass, m{sub hdm}{sup eff} < eV, that are not fully-thermalised, Δ N{sub eff} < 1. We argue that their almost automatic interpretation as a sterile neutrino species is neither from theoretical nor practical parsimony principles preferred over HDM formed by decay products (daughters) of an out-of-equilibrium particle decay. While daughters mimic sterile neutrinos in N{sub eff} and m{sub hdm}{sup eff}, there are opportunities to assess this possibility in likelihood analyses. Connecting cosmological parameters and moments of momentum distribution functions, we show that—also in the case of mass-degenerate daughters with indistinguishable main physical effects—the mimicry breaks down when the next moment, the skewness, is considered. Predicted differences of order one in the root-mean-squares of absolute momenta are too small for current sensitivities.

  11. Effects of sterilization on poly(ethylene glycol) hydrogels.

    PubMed

    Kanjickal, Deenu; Lopina, Stephanie; Evancho-Chapman, M Michelle; Schmidt, Steven; Donovan, Duane

    2008-12-01

    The past few decades have witnessed a dramatic increase in the development of polymeric biomaterials. These biomaterials have to undergo a sterilization procedure before implantation. However, many sterilization procedures have been shown to profoundly affect polymer properties. Poly(ethylene glycol) hydrogels have gained increasing importance in the controlled delivery of therapeutics and in tissue engineering. We evaluated the effect of ethylene oxide (EtO), hydrogen peroxide (H(2)O(2)), and gamma sterilization of poly(ethylene glycol) hydrogels on properties relevant to controlled drug delivery and tissue engineering. We observed that the release of cyclosporine (CyA) (an immunosuppressive drug that is effective in combating tissue rejection following organ transplantation) was significantly affected by the type of sterilization. However, that was not the case with rhodamine B, a dye. Hence, the drug release characteristics were observed to be dependent not only on the sterilization procedure but also on the type of agent that needs to be delivered. In addition, differences in the swelling ratios for the sterilized and unsterilized hydrogels were statistically significant for 1:1 crosslinked hydrogels derived from the 8000 MW polymer. Significant differences were also observed for gamma sterilization for 1:1 crosslinked hydrogels derived from the 3350 MW polymer and also the 2:1 crosslinked hydrogels derived from the 8000 MW polymer. Atomic force microscopy (AFM) studies revealed that the roughness parameter for the unsterilized and EtO-sterilized PEG hydrogels remained similar. However, a statistically significant reduction of the roughness parameter was observed for the H(2)O(2) and gamma-sterilized samples. Electron spin resonance (ESR) studies on the unsterilized and the sterilized samples revealed the presence of the peroxy and the triphenyl methyl carbon radical in the samples. The gamma and the H(2)O(2)-sterilized samples were observed to have a much

  12. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section 880.6860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas...

  13. 21 CFR 522.2150 - Stanozolol sterile suspension.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Stanozolol sterile suspension. 522.2150 Section 522.2150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.2150 Stanozolol sterile suspension....

  14. Irradiation of Anastrepha ludens (Diptera: Tephritidae) revisited: optimizing sterility induction.

    PubMed

    Rull, Juan; Diaz-Fleischer, Francisco; Arredondo, Jose

    2007-08-01

    Irradiation doses currently applied to sterilize Mexican fruit flies, Anastrepha ludens (Loew) (Diptera: Tephritidae), for release under the sterile insect technique eradication campaign in Mexico, were reviewed in an effort to increase sterile male performance in the field. A dose maximizing sterility induction into wild populations was sought by balancing somatic fitness with genetic sterility. Doses of 40, 60, and 80 Gy induced 95% or more sterility in all males, which in turn induced similar degrees of sterility into a cohort of wild flies in the laboratory. However, a low dose of 40 Gy was sufficient to completely suppress egg production in females. Similarly, a mild carryover of genetic damage might have been transferred to the F1 progeny of males irradiated at 40 Gy crossed with fertile wild females. Our results suggest that the 80-Gy dose currently applied in Mexico can be lowered substantially without jeopardizing program goals. This view could be strengthened by comparing performance of males irradiated at different doses under more natural settings. In general, we discuss the value of determining irradiation doses for pest species where females are more radiosensitive than males, by selecting the dose that causes 100% sterility in females. PMID:17849864

  15. Penetration by Gases to Sterilize Interior Surfaces of Confined Spaces

    PubMed Central

    Opfell, John B.; Wang, Yui-Loong; Louderback, Allan L.; Miller, Curtis E.

    1964-01-01

    The rate of penetration of gaseous sterilizing agents into confined spaces can be predicted from physical and chemical considerations. The exposure times required to obtain sterilizing concentrations of ethylene oxide in several configurations of confined space were predicted by computation and illustrated by experiment. The results of the computations are presented graphically. PMID:14106936

  16. Low-temperature sterilization alternatives in the 1990s

    SciTech Connect

    Schneider, P. . Surgical Div.)

    1994-01-01

    Vapor phase hydrogen peroxide, gas plasma, ozone, and peracetic acids have been commercialized as alternative technologies for low-temperature sterilization. None are viewed as a total replacement for ethylene oxide for on-site sterilization of reusable, heat-sensitive medical materials in healthcare facilities.

  17. 21 CFR 522.1890 - Sterile prednisone suspension.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile prednisone suspension. 522.1890 Section 522.1890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.1890 Sterile prednisone suspension. (a)...

  18. Future short-baseline sterile neutrino searches with accelerators

    SciTech Connect

    Spitz, J.

    2015-07-15

    A number of experimental anomalies in neutrino oscillation physics point to the existence of at least one light sterile neutrino. This hypothesis can be precisely tested using neutrinos from reactors, radioactive isotopes, and particle accelerators. The focus of these proceedings is on future dedicated short-baseline sterile neutrino searches using accelerators.

  19. Sterilization of the Mentally Ill and the Mentally Retarded.

    ERIC Educational Resources Information Center

    National Association of State Mental Health Program Directors, Washington, DC.

    Reported were the results of a survey on the sterilization of the mentally ill and the mentally retarded. Thirty-three states responded to the survey. It was found that 17 states have a sterilization statute, but the existence of the statute was explained not to mean that the procedure was used. Sixteen states responded that they did not have a…

  20. 7 CFR 305.28 - Kiln sterilization treatment schedule.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Kiln sterilization treatment schedule. 305.28 Section 305.28 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH... sterilization treatment schedule. T404-b-4 Dry bulb temperature( °F) Wet bulb depression( °F)...

  1. Parents' Attitudes toward Sterilization of Their Mentally Retarded Children.

    ERIC Educational Resources Information Center

    Wolf, Lucille; Zarfas, Donald E.

    1982-01-01

    One hundred fifty-seven parents' attitudes toward sterilization and the sexuality of their retarded offspring were identified. Parent and child characteristics associated with these attitudes were investigated. Findings indicated that parents substantially concurred with the principle of sterilization (71 percent for involuntary, 67 percent for…

  2. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  3. Alternative methods of terminal sterilization for biologically active macromolecules.

    PubMed

    Yaman, A

    2001-11-01

    The traditional perception within the pharmaceutical industry of the manufacture of injectable drug products is that active pharmaceutical ingredients (API) that are peptides, proteins or biopolymers, such as poly(DL-lactide) (PLA) and poly(DL-lactideco-glycolide) (PLGA), cannot be terminally sterilized. This perception exists largely because terminal sterilization is assumed by many to be only carried out by steam sterilization in a standard autoclave. Thus, it is understood that these API candidates must be manufactured by aseptic techniques. With the current technological advances in the area of protein and peptide sterilization, which has largely come from the food industry and has in recent years been developed for pharmaceutical use, techniques have been developed for the terminal sterilization of thermally sensitive APIs and biopolymers. In this review, the focus will be on the four major types of sterilization that are presented in the literature: (i) gamma-irradiation; (ii) e-Beam; (iii) natural light; and (iv) microwave. Each of these sterilization techniques present advantages and disadvantages for use in large-scale terminal sterilization of bioactive macromolecules. PMID:11899616

  4. Sterile devices: A GMP (Good Manufacturing Practices) workshop manual

    NASA Astrophysics Data System (ADS)

    Derision, R.; Lower, A.; Bimonte, R.

    1983-05-01

    The manual, which covers GMPs for sterilization processes, presents model procedures and forms as well as a variety of articles and reprints. It is a compilation of GMP materials that small device firms may find useful in understanding how some manufacturers have successfully compiled with the GMP requirements as they apply to the manufacture of sterile devices.

  5. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section 880.6860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas...

  6. Long-term sterility of orthodontic-surgical appliances.

    PubMed

    Brusca, María I; Nastri, Natalia; Mosca, Christian O; Nastri, María L; Rosa, Alcira C

    2004-01-01

    The aim of this study was to evaluate the long-term sterility of new dental appliances according to the non rigid wrapping employed and assess the effectiveness of sterilization in a steam autoclave at 134 degrees for 20 minutes using physical, chemical, and biological indicators. All the experimental (E) samples and the control samples (C) were assigned to one of three groups according to the type of packaging: paper bag (E1), paper/plastic pouch (E2), nylon tubing bag (E3). Each bag contained standardized orthodontic wires and brackets and sterility indicators. The samples were evaluated at the following experimental times: immediately, and 6, 12, 24 and 30 months post-sterilization. The samples were analyzed under aerobic and anaerobic conditions in keeping with the protocol currently in use at the Department of Microbiology, School of Dentistry, University of Buenos Aires. The group of control, non-sterilized samples (C1, C2, C3) were analyzed prior to the onset of the study, and were found to be contaminated. None of the sterilized samples in any of the three experimental groups evidenced contamination at any of the experimental times. The results showed that, under the present conditions, the packages and orthodontic appliances remained sterile for 30 months. These results show the importance of controlling sterility and the storage conditions over time for all the orthodontic/surgical appliances used in invasive treatments. PMID:15584258

  7. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... dry heat sterilizer shall have an approved PMA or declared completed PDP in effect before being placed... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat...

  8. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... dry heat sterilizer shall have an approved PMA or declared completed PDP in effect before being placed... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat...

  9. 21 CFR 872.6730 - Endodontic dry heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... dry heat sterilizer shall have an approved PMA or declared completed PDP in effect before being placed... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endodontic dry heat sterilizer. 872.6730 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6730 Endodontic dry heat...

  10. Efficacy of various methods of sterilization of acupuncture needles.

    PubMed

    Sisco, V; Winters, L L; Zange, L L; Brennan, P C

    1988-04-01

    The iatrogenic transmission of hepatitis B virus by inadequately sterilized acupuncture needles recently has been reported. Because some licensed chiropractors use acupuncture as a therapeutic modality, we have evaluated sterilization methods for these needles, which would be adaptable for use in a chiropractic office. Dry heat, boiling water, pressurized steam, sodium hypochlorite, and 70% alcohol were compared with a glass bead dry heat sterilizer originally developed for dental instruments. Presterilized acupuncture needles were contaminated with Bacillus stearothermophilus, Escherichia coli or Staphylococcus epidermidis and sterilized for intervals ranging from 5 sec to 30 min. The needles were then cultured to determine the efficacy of the sterilization regimen. Seventy percent alcohol was ineffective as a sterilization method. In terms of both time and convenience, the glass bead apparatus was the most efficient of the remaining methods tested. B. stearothermophilus-contaminated acupuncture needles were sterilized within 10 sec of exposure to preheated glass beads. Less than 10 sec exposure killed E. coli and S. epidermidis. A significant advantage of the glass bead sterilizer over the other methods was the absence of physical damage to the needles. PMID:3290376

  11. 21 CFR 522.1155 - Imidocarb dipropionate sterile powder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Imidocarb dipropionate sterile powder. 522.1155 Section 522.1155 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... § 522.1155 Imidocarb dipropionate sterile powder. (a) Specifications. Imidocarb dipropionate powder...

  12. 21 CFR 522.1155 - Imidocarb dipropionate sterile powder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Imidocarb dipropionate sterile powder. 522.1155 Section 522.1155 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... § 522.1155 Imidocarb dipropionate sterile powder. (a) Specifications. Imidocarb dipropionate powder...

  13. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section 880.6860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas...

  14. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects §...

  15. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects §...

  16. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects §...

  17. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects §...

  18. An Evaluation of State Energy Program Accomplishments: 2002 Program Year

    SciTech Connect

    Schweitzer, M.

    2005-07-13

    SEP activities performed by the states during the 2002 program year, based on primary data provided by the states themselves. This is the second systematic evaluation of SEP accomplishments performed by Oak Ridge National Laboratory (ORNL) for DOE. A report documenting the findings of the first study was published in January 2003 (Schweitzer et.al., 2003).

  19. Accomplishing Mars exploration goals by returning a simple "locality" sample

    NASA Astrophysics Data System (ADS)

    McKay, G.; Draper, D.; Bogard, D.; Agee, C.; Ming, D.; Jones, J.

    A major stumbling block to a Mars sample return (MSR) mission is cost. This problem is greatly exacerbated by using elaborate rovers, sophisticated on-board instruments, and complex sample selection techniques to maximize diversity. We argue that many key science goals of the Mars Exploration Program may be accomplished by returning a simple "locality" sample from a well-chosen landing site. Such a sample , collected by a simple scoop, would consist of local regolith containing soil, windblown fines, and lithic fragments (plus Martian atmosphere). Even the simplest sample return mission could revolutionize our understanding of Mars, without the need for expensive rovers or sophisticated on-board instruments. We expect that by the time a MSR mission could be flown, information from the Mars Odyssey, Mars Express, 2003 Mars Exploration Rovers, and 2005 Mars Reconnaissance Orbiter will be sufficient to choose a good landing site. Returned samples of Martian regolith have the potential to answer key questions of fundamental importance to the Mars Exploration Program: The search for life; the role and history of water and other volatiles; interpreting remotely-sensed spectral data; and understanding the planet as a system. A locality sample can further the search for life by identifying trace organics, biogenic elements and their isotopic compositions, evidence for water such as hydrous minerals or cements, the Martian soil oxidant, and trace biomarkers. Learning the nature and timing of atmosphere-soil-rock interactions will improve understanding of the role and history of water. An atmosphere sample will reveal fundamental information about current atmospheric processes. Information about the mineralogy and lithology of sample materials, the extent of impact gardening, and the nature of dust coatings and alteration rinds will provide much-needed ground truth for interpreting remotely-sensed data, including Mars Pathfinder. Basic planetology questions that might be

  20. Microwave sterilization of nitrous oxide nasal hoods contaminated with virus

    SciTech Connect

    Young, S.K.; Graves, D.C.; Rohrer, M.D.; Bulard, R.A.

    1985-12-01

    Although there exists a desire to eliminate the possibility of cross-infection from microbial contaminated nitrous oxide nasal hoods, effective and practical methods of sterilization in a dental office are unsatisfactory. Microwaves have been used to sterilize certain contaminated dental instruments without damage. In this study nasal hoods contaminated with rhinovirus, parainfluenza virus, adenovirus, and herpes simplex virus were sterilized in a modified microwave oven. Ninety-five percent of the virus activity was destroyed after 1 minute of exposure of the contaminated nasal hoods to microwaves. By the end of 4 minutes, complete inactivation of all four viruses was found. Repeated exposure of the nasal hoods to microwaves resulted in no damage to their texture and flexibility. Microwave sterilization may potentially provide a simple and practical method of sterilizing nitrous oxide anesthesia equipment in a dental or medical practice.