  1. Low-overhead accrual failure detector.

    PubMed

    Ren, Xiao; Dong, Jian; Liu, Hongwei; Li, Yang; Yang, Xiaozong

    2012-01-01

    Failure detectors are one of the fundamental components for building a distributed system with high availability. In order to maintain the efficiency and scalability of failure detection in a complicated large-scale distributed system, accrual failure detectors that can adapt to multiple applications have been studied extensively. In this paper, an new accrual failure detector--LA-FD with low system overhead has been proposed specifically for current mobile network equipment on the Internet whose processing power, memory space and power supply are all constrained. It does not rely on the probability distribution of message transmission time, or on the maintenance of a history message window. By simple calculation, LA-FD provides adaptive failure detection service with high accuracy to multiple upper applications. The related experiments and results have also been presented.

  2. A Weibull distribution accrual failure detector for cloud computing

    PubMed Central

    Wu, Zhibo; Wu, Jin; Zhao, Yao; Wen, Dongxin

    2017-01-01

    Failure detectors are used to build high availability distributed systems as the fundamental component. To meet the requirement of a complicated large-scale distributed system, accrual failure detectors that can adapt to multiple applications have been studied extensively. However, several implementations of accrual failure detectors do not adapt well to the cloud service environment. To solve this problem, a new accrual failure detector based on Weibull Distribution, called the Weibull Distribution Failure Detector, has been proposed specifically for cloud computing. It can adapt to the dynamic and unexpected network conditions in cloud computing. The performance of the Weibull Distribution Failure Detector is evaluated and compared based on public classical experiment data and cloud computing experiment data. The results show that the Weibull Distribution Failure Detector has better performance in terms of speed and accuracy in unstable scenarios, especially in cloud computing. PMID:28278229

  3. A Weibull distribution accrual failure detector for cloud computing.

    PubMed

    Liu, Jiaxi; Wu, Zhibo; Wu, Jin; Dong, Jian; Zhao, Yao; Wen, Dongxin

    2017-01-01

    Failure detectors are used to build high availability distributed systems as the fundamental component. To meet the requirement of a complicated large-scale distributed system, accrual failure detectors that can adapt to multiple applications have been studied extensively. However, several implementations of accrual failure detectors do not adapt well to the cloud service environment. To solve this problem, a new accrual failure detector based on Weibull Distribution, called the Weibull Distribution Failure Detector, has been proposed specifically for cloud computing. It can adapt to the dynamic and unexpected network conditions in cloud computing. The performance of the Weibull Distribution Failure Detector is evaluated and compared based on public classical experiment data and cloud computing experiment data. The results show that the Weibull Distribution Failure Detector has better performance in terms of speed and accuracy in unstable scenarios, especially in cloud computing.

  4. Inverter ratio failure detector

    NASA Technical Reports Server (NTRS)

    Wagner, A. P.; Ebersole, T. J.; Andrews, R. E. (Inventor)

    1974-01-01

    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

  5. Triac failure detector

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1983-01-01

    A failure detector is provided for detecting unidirectional failures in triacs, particularly as used in power factor controllers for induction motors. In a first embodiment, the triac voltage waveform is sensed and upon detection of an unbalanced signal, corresponding to failure of the triac in either the positive or negative direction, the triac is turned full on in both directions. In a second embodiment, a pair of pulsed signals are derived, the pulse durations of which are proportional to the phase difference between the load current and voltage for each half cycle, and the triac is turned full on responsive to a difference in pulse duration between the half cycle signals. An unidirectional open circuit detector is adapted to use a signal from either of the first and second embodiment to turn the triac off in response to an open circuit failure in either direction.

  6. DC-to-AC inverter ratio failure detector

    NASA Technical Reports Server (NTRS)

    Ebersole, T. J.; Andrews, R. E.

    1975-01-01

    Failure detection technique is based upon input-output ratios, which is independent of inverter loading. Since inverter has fixed relationship between V-in/V-out and I-in/I-out, failure detection criteria are based on this ratio, which is simply inverter transformer turns ratio, K, equal to primary turns divided by secondary turns.

  7. Oracle accrual plans from requirements to implementation

    SciTech Connect

    Rivera, Christine K

    2009-01-01

    Implementing any new business software can be an intimidating prospect and this paper is intended to offer some insight in to how to approach this challenge with some fundamental rules for success. Los Alamos National Laboratory (LANL) had undergone an original ERP implementation of HRMS, Oracle Advanced Benefits, Worker Self Service, Manager Self Service, Project Accounting, Financials and PO, and recently completed a project to implement Oracle Payroll, Time and Labor and Accrual Plans. This paper will describe some of the important lessons that can be applied to any implementation as a whole, and then specifically how this knowledge was applied to the design and deployment of Oracle Accrual Plans for LANL. Finally, detail on the functionality available in Oracle Accrual Plans will be described, as well as the detailed setups.that were utilized at LANL.

  8. Photomultiplier tube failure under hydrostatic pressure in future neutrino detectors

    DOE PAGES

    Chambliss, K.; Diwan, M.; Simos, N.; ...

    2014-10-09

    Failure of photomultiplier tubes (PMTs) under hydrostatic pressure is a concern in neutrino detection, specifically, in the proposed Long-Baseline Neutrino Experiment project. Controlled hydrostatic implosion tests were performed on prototypic PMT bulbs of 10-inch diameter and recorded using high speed filming techniques to capture failures in detail. These high-speed videos were analyzed frame-by-frame in order to identify the origin of a crack, measure the progression of individual crack along the surface of the bulb as it propagates through the glass, and estimate crack velocity. Crack velocity was calculated for each individual crack, and an average velocity was determined for allmore » measurable cracks on each bulb. Overall, 32 cracks were measured in 9 different bulbs tested. Finite element modeling (FEM) of crack formation and growth in prototypic PMT shows stress concentration near the middle section of the PMT bulbs that correlates well with our crack velocity measurements in that section. The FEM model predicts a crack velocity value that is close to the terminal crack velocity reported. Our measurements also reveal significantly reduced crack velocities compared to terminal crack velocities measured in glasses using fracture mechanics testing and reported in literature.« less

  9. Photomultiplier tube failure under hydrostatic pressure in future neutrino detectors

    SciTech Connect

    Chambliss, K.; Diwan, M.; Simos, N.; Sundaram, S. K.

    2014-10-09

    Failure of photomultiplier tubes (PMTs) under hydrostatic pressure is a concern in neutrino detection, specifically, in the proposed Long-Baseline Neutrino Experiment project. Controlled hydrostatic implosion tests were performed on prototypic PMT bulbs of 10-inch diameter and recorded using high speed filming techniques to capture failures in detail. These high-speed videos were analyzed frame-by-frame in order to identify the origin of a crack, measure the progression of individual crack along the surface of the bulb as it propagates through the glass, and estimate crack velocity. Crack velocity was calculated for each individual crack, and an average velocity was determined for all measurable cracks on each bulb. Overall, 32 cracks were measured in 9 different bulbs tested. Finite element modeling (FEM) of crack formation and growth in prototypic PMT shows stress concentration near the middle section of the PMT bulbs that correlates well with our crack velocity measurements in that section. The FEM model predicts a crack velocity value that is close to the terminal crack velocity reported. Our measurements also reveal significantly reduced crack velocities compared to terminal crack velocities measured in glasses using fracture mechanics testing and reported in literature.

  10. 29 CFR 2530.204-2 - Accrual computation period.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... participation are credited with a partial year of participation on a prorata basis. For example, if the plan... first accrual computation period under the plan as amended is treated as a partial accrual computation... partial accrual computation period, the following rules shall apply: (i) A plan having a minimum...

  11. Can the referring surgeon enhance accrual of breast cancer patients to medical and radiation oncology trials? The ENHANCE study

    PubMed Central

    Arnaout, A.; Kuchuk, I.; Bouganim, N.; Pond, G.; Verma, S.; Segal, R.; Dent, S.; Gertler, S.; Song, X.; Kanji, F.; Clemons, M.

    2016-01-01

    Introduction The accrual rate to clinical trials in oncology remains low. In this exploratory pilot study, we prospectively assessed the role that engaging a referring surgeon plays in enhancing nonsurgical oncologic clinical trial accrual. Methods Newly diagnosed breast cancer patients were seen by a surgeon who actively introduced specific patient-and physician-centred strategies to increase clinical trial accrual. Patient-centred strategies included providing patients, before their oncology appointment, with information about specific clinical trials for which they might be eligible, as evaluated by the surgeon. The attitudes of the patients about clinical trials and the interventions used to improve accrual were assessed at the end of the study. The primary outcome was the clinical trial accrual rate during the study period. Results Overall clinical trial enrolment during the study period among the 34 participating patients was 15% (5 of 34), which is greater than the institution’s historical average of 7%. All patients found the information delivered by the surgeon before the oncology appointment to be very helpful. Almost three quarters of the patients (73%) were informed about clinical trials by their oncologist. The top reasons for nonparticipation reported by the patients who did not participate in clinical trials included lack of interest (35%), failure of the oncologist to mention clinical trials (33%), and inconvenience (19%). Conclusions Accrual of patients to clinical trials is a complex multistep process with multiple potential barriers. The findings of this exploratory pilot study demonstrate a potential role for the referring surgeon in enhancing nonsurgical clinical trial accrual. PMID:27330365

  12. An improved accrual: reducing medical malpractice year-end adjustments.

    PubMed

    Frese, Richard C

    2012-08-01

    Healthcare organizations can improve their year-end malpractice insurance accruals by taking the following steps: Maintain productive communication. Match accrual and accounting policies. Adjust amount of credit to own historical loss experience. Request more frequent analysis. Obtain a second opinion.

  13. A Failure Mode in Dense Infrared Detector Arrays Resulting in Increased Dark Current

    NASA Astrophysics Data System (ADS)

    Pinkie, Benjamin; Bellotti, Enrico

    2016-09-01

    In this paper, we investigate a failure mode that arises in dense infrared focal plane detector arrays as a consequence of the interactions of neighboring pixels through the minority carrier profiles in the common absorber layer. We consider the situation in which one pixel in a hexagonal array becomes de-biased relative to its neighbors and show that the dark current in the six neighboring pixels increases exponentially as a function of the difference between the nominal and anomalous biases. Moreover, we show that the current increase in the six nearest-neighbor pixels is in total larger than that by which the current in the affected pixel decreases, causing a net increase in the dark current. The physical origins of this effect are explained as being due to increased lateral diffusion currents that arise as a consequence of breaking the symmetry of the minority carrier profiles. We then perform a parametric study to quantify the magnitude of this effect for a number of detector geometric parameters, operating temperatures, and spectral bands. Particularly, numerical simulations are carried out for short-, mid-, and long-wavelength HgCdTe infrared detectors operating between 77 K and 210 K. We show that this effect is most prevalent in architectures for which the lateral diffusion current is the largest component of the total dark current—high operating temperature devices with narrow epitaxial absorber thicknesses and pitches small compared to the diffusion length of minority carriers. These results could prove significant particularly for short- and mid-wave infrared detectors, which are typically designed to fit these conditions.

  14. Independent association of glucocorticoids with damage accrual in SLE

    PubMed Central

    Apostolopoulos, Diane; Kandane-Rathnayake, Rangi; Raghunath, Sudha; Hoi, Alberta; Nikpour, Mandana; Morand, Eric F

    2016-01-01

    Objectives To determine factors associated with damage accrual in a prospective cohort of patients with SLE. Methods Patients with SLE who attended the Lupus Clinic at Monash Health, Australia, between 2007 and 2013 were studied. Clinical variables included disease activity (Systemic Lupus Erythematosus Disease Activity Index-2K, SLEDAI-2K), time-adjusted mean SLEDAI, cumulative glucocorticoid dose and organ damage (Systemic Lupus International Collaborating Clinics Damage Index (SDI)). Multivariate logistic regression analyses were performed to identify factors associated with damage accrual. Results A total of 162 patients were observed over a median (IQR) 3.6 (2.0–4.7) years. Seventy-five per cent (n=121) of patients received glucocorticoids. Damage accrual was significantly more frequent in glucocorticoid-exposed patients (42% vs 15%, p<0.01). Higher glucocorticoid exposure was independently associated with overall damage accrual after controlling for factors including ethnicity and disease activity and was significant at time-adjusted mean doses above 4.42 mg prednisolone/day; the OR of damage accrual in patients in the highest quartile of cumulative glucocorticoid exposure was over 10. Glucocorticoid exposure was independently associated with damage accrual in glucocorticoid-related and non-glucocorticoid related domains of the SDI. Conclusions Glucocorticoid use is independently associated with the accrual of damage in SLE, including in non-glucocorticoid related domains. PMID:27933196

  15. Detectors

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore; Bounds, John Alan; Allander, Krag

    2002-01-01

    The apparatus and method provide techniques through which both alpha and beta emission determinations can be made simultaneously using a simple detector structure. The technique uses a beta detector covered in an electrically conducting material, the electrically conducting material discharging ions generated by alpha emissions, and as a consequence providing a measure of those alpha emissions. The technique also offers improved mountings for alpha detectors and other forms of detectors against vibration and the consequential effects vibration has on measurement accuracy.

  16. 12 CFR 621.9 - Reinstatement to accrual status.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... REQUIREMENTS Loan Performance and Valuation Assessment § 621.9 Reinstatement to accrual status. A loan may be... is supported by a period of sustained performance in accordance with the contractual terms of the note and/or loan agreement. Sustained performance will generally be demonstrated by 6...

  17. 12 CFR 621.9 - Reinstatement to accrual status.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... REQUIREMENTS Loan Performance and Valuation Assessment § 621.9 Reinstatement to accrual status. A loan may be... is supported by a period of sustained performance in accordance with the contractual terms of the note and/or loan agreement. Sustained performance will generally be demonstrated by 6...

  18. 12 CFR 621.9 - Reinstatement to accrual status.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... REQUIREMENTS Loan Performance and Valuation Assessment § 621.9 Reinstatement to accrual status. A loan may be... is supported by a period of sustained performance in accordance with the contractual terms of the note and/or loan agreement. Sustained performance will generally be demonstrated by 6...

  19. An Experiment of Student Understanding of Accruals versus Cash Flows

    ERIC Educational Resources Information Center

    Miranda-Lopez, Jose Eduardo; Nichols, Linda M.

    2007-01-01

    The concepts of both accrual accounting and cash basis accounting need to be thoroughly understood by accounting graduates as they enter the workplace. In making decisions, both managers and investors often may need to make adjustments from one basis to the other. But do students really understand these concepts? This study uses an experimental…

  20. 29 CFR 2530.204-1 - Year of participation for benefit accrual.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ADMINISTRATION, DEPARTMENT OF LABOR MINIMUM STANDARDS FOR EMPLOYEE PENSION BENEFIT PLANS UNDER THE EMPLOYEE... BENEFIT PLANS Participation, Vesting and Benefit Accrual § 2530.204-1 Year of participation for benefit... requirements relating to benefit accrual under a defined benefit pension plan. Some of these requirements...

  1. 34 CFR 34.30 - Application of payments and accrual of interest.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Application of payments and accrual of interest. 34.30 Section 34.30 Education Office of the Secretary, Department of Education ADMINISTRATIVE WAGE GARNISHMENT § 34.30 Application of payments and accrual of interest. We apply payments received through...

  2. 34 CFR 34.30 - Application of payments and accrual of interest.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 1 2012-07-01 2012-07-01 false Application of payments and accrual of interest. 34.30 Section 34.30 Education Office of the Secretary, Department of Education ADMINISTRATIVE WAGE GARNISHMENT § 34.30 Application of payments and accrual of interest. We apply payments received through...

  3. 34 CFR 34.30 - Application of payments and accrual of interest.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false Application of payments and accrual of interest. 34.30 Section 34.30 Education Office of the Secretary, Department of Education ADMINISTRATIVE WAGE GARNISHMENT § 34.30 Application of payments and accrual of interest. We apply payments received through...

  4. 34 CFR 34.30 - Application of payments and accrual of interest.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 1 2013-07-01 2013-07-01 false Application of payments and accrual of interest. 34.30 Section 34.30 Education Office of the Secretary, Department of Education ADMINISTRATIVE WAGE GARNISHMENT § 34.30 Application of payments and accrual of interest. We apply payments received through...

  5. 34 CFR 34.30 - Application of payments and accrual of interest.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 1 2011-07-01 2011-07-01 false Application of payments and accrual of interest. 34.30 Section 34.30 Education Office of the Secretary, Department of Education ADMINISTRATIVE WAGE GARNISHMENT § 34.30 Application of payments and accrual of interest. We apply payments received through...

  6. Implementation Status of Accrual Accounting System in Health Sector

    PubMed Central

    Mehrolhassani, Mohammad Hossien; Khayatzadeh-Mahani, Akram; Emami, Mozhgan

    2015-01-01

    Introduction: Management of financial resources in health systems is one of the major issues of concern for policy makers globally. As a sub-set of financial management, accounting system is of paramount importance. In this paper, which presents part of the results of a wider research project on transition process from a cash accounting system to an accrual accounting system, we look at the impact of components of change on implementation of the new system. Implementing changes is fraught with many obstacles and surveying these challenges will help policy makers to better overcome them. Methods: The study applied a quantitative manner in 2012 at Kerman University of Medical Science in Iran. For the evaluation, a teacher made valid questionnaire with Likert scale was used (Cranach’s alpha of 0.89) which included 7 change components in accounting system. The study population was 32 subordinate units of Kerman University of Medical Sciences and for data analysis, descriptive and inferential statistics and correlation coefficient in SPSS version 19 were used. Results: Level of effect of all components on the implementation was average downward (5.06±1.86), except for the component “management & leadership (3.46±2.25)” (undesirable from external evaluators’ viewpoint) and “technology (6.61±1.92) and work processes (6.35±2.19)” (middle to high from internal evaluators’ viewpoint). Conclusions: Results showed that the establishment of accrual accounting system faces infrastructural challenges, especially the components of leadership and management and followers. As such, developing effective measures to overcome implementation obstacles should target these components. PMID:25560337

  7. 26 CFR 1.822-7 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-7 Amortization of premium and accrual of...

  8. 26 CFR 1.822-10 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-10 Amortization of premium and accrual of...

  9. 26 CFR 1.822-10 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-10 Amortization of premium and accrual of...

  10. 26 CFR 1.822-10 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-10 Amortization of premium and accrual of discount. (a)...

  11. 26 CFR 1.822-3 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-3 Amortization of premium and accrual of...

  12. 26 CFR 1.822-7 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-7 Amortization of premium and accrual of...

  13. 26 CFR 1.822-3 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-3 Amortization of premium and accrual of...

  14. 26 CFR 1.822-10 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-10 Amortization of premium and accrual of...

  15. 26 CFR 1.822-10 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-10 Amortization of premium and accrual of...

  16. 26 CFR 1.822-3 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-3 Amortization of premium and accrual of discount....

  17. 26 CFR 1.822-3 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-3 Amortization of premium and accrual of...

  18. 26 CFR 1.822-7 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-7 Amortization of premium and accrual of discount....

  19. 26 CFR 1.822-7 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-7 Amortization of premium and accrual of...

  20. 26 CFR 1.822-7 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-7 Amortization of premium and accrual of...

  1. 26 CFR 1.822-3 - Amortization of premium and accrual of discount.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Certain Marine Insurance Companies and Other Than Fire Or Flood Insurance Companies Which Operate on Basis of Perpetual Policies Or Premium Deposits) § 1.822-3 Amortization of premium and accrual of...

  2. Donepezil regulates energy metabolism and favors bone mass accrual.

    PubMed

    Eimar, Hazem; Alebrahim, Sharifa; Manickam, Garthiga; Al-Subaie, Ahmed; Abu-Nada, Lina; Murshed, Monzur; Tamimi, Faleh

    2016-03-01

    The autonomous nervous system regulates bone mass through the sympathetic and parasympathetic arms. The sympathetic nervous system (SNS) favors bone loss whereas the parasympathetic nervous system (PNS) promotes bone mass accrual. Donepezil, a central-acting cholinergic agonist, has been shown to down-regulate SNS and up-regulate PNS signaling tones. Accordingly, we hypothesize that the use of donepezil could have beneficial effects in regulating bone mass. To test our hypothesis, two groups of healthy female mice were treated either with donepezil or saline. Differences in body metabolism and bone mass of the treated groups were compared. Body and visceral fat weights as well as serum leptin level were increased in donepezil-treated mice compared to control, suggesting that donepezil effects on SNS influenced metabolic activity. Donepezil-treated mice had better bone quality than controls due to a decrease in osteoclasts number. These results indicate that donepezil is able to affect whole body energy metabolism and favors bone mass in young female WT mice.

  3. Report on a Delphi process and workshop to improve accrual to cancer clinical trials

    PubMed Central

    Bell, J.A.H.; Balneaves, L.G.; Kelly, M.T.; Richardson, H.

    2016-01-01

    Cancer clinical trials (ccts) are essential for furthering knowledge and developing effective interventions to improve the lives of people living with cancer in Canada. Randomized controlled trials are particularly important for developing evidence-based health care interventions. To produce robust and relevant research conclusions, timely and sufficient accrual to ccts is essential. The present report delivers the key recommendations emerging from a workshop meeting, Improve Accrual to Cancer Clinical Trials, that was hosted by the Canadian Cancer Trials Group and funded by the Canadian Institutes of Health Research. The meeting, which took place in Toronto, Ontario, in April 2012 before the Canadian Cancer Trials Group annual spring meeting, brought together key stakeholders from across Canada to explore creative strategies for improving accrual to ccts. The objectives of the workshop were to provide an opportunity for knowledge exchange with respect to the research evidence and the ethics theory related to cct accrual and to promote discussion of best practices and policies related to enhancing cct access and accrual in Canada. The workshop provided the foundation for establishing new interdisciplinary research collaborations to overcome the identified barriers to cct participation in Canada. Meeting participants also supported the development of evidence-based policies and practices to make trials more accessible to Canadians living with cancer.

  4. 26 CFR 1.436-1 - Limits on benefits and benefit accruals under single employer defined benefit plans.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 5 2013-04-01 2013-04-01 false Limits on benefits and benefit accruals under... § 1.436-1 Limits on benefits and benefit accruals under single employer defined benefit plans. (a...) Limitations on prohibited payments. (1) AFTAP less than 60 percent. (2) Bankruptcy. (3) Limited payment...

  5. 20 CFR 255.14 - Waiver not available when recovery can be made from accrual of social security benefits.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... from accrual of social security benefits. 255.14 Section 255.14 Employees' Benefits RAILROAD RETIREMENT... available when recovery can be made from accrual of social security benefits. Where the overpayment is the... individual's entitlement to social security benefits and recovery of such overpayment may be made by...

  6. 20 CFR 255.14 - Waiver not available when recovery can be made from accrual of social security benefits.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... made from accrual of social security benefits. 255.14 Section 255.14 Employees' Benefits RAILROAD... available when recovery can be made from accrual of social security benefits. Where the overpayment is the... individual's entitlement to social security benefits and recovery of such overpayment may be made by...

  7. 20 CFR 255.14 - Waiver not available when recovery can be made from accrual of social security benefits.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... from accrual of social security benefits. 255.14 Section 255.14 Employees' Benefits RAILROAD RETIREMENT... available when recovery can be made from accrual of social security benefits. Where the overpayment is the... individual's entitlement to social security benefits and recovery of such overpayment may be made by...

  8. 20 CFR 255.14 - Waiver not available when recovery can be made from accrual of social security benefits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... made from accrual of social security benefits. 255.14 Section 255.14 Employees' Benefits RAILROAD... available when recovery can be made from accrual of social security benefits. Where the overpayment is the... individual's entitlement to social security benefits and recovery of such overpayment may be made by...

  9. 20 CFR 255.14 - Waiver not available when recovery can be made from accrual of social security benefits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... made from accrual of social security benefits. 255.14 Section 255.14 Employees' Benefits RAILROAD... available when recovery can be made from accrual of social security benefits. Where the overpayment is the... individual's entitlement to social security benefits and recovery of such overpayment may be made by...

  10. The longitudinal effects of physical activity and dietary calcium on bone mass accrual across stages of pubertal development.

    PubMed

    Lappe, Joan M; Watson, Patrice; Gilsanz, Vicente; Hangartner, Thomas; Kalkwarf, Heidi J; Oberfield, Sharon; Shepherd, John; Winer, Karen K; Zemel, Babette

    2015-01-01

    Childhood and adolescence are critical periods of bone mineral content (BMC) accrual that may have long-term consequences for osteoporosis in adulthood. Adequate dietary calcium intake and weight-bearing physical activity are important for maximizing BMC accrual. However, the relative effects of physical activity and dietary calcium on BMC accrual throughout the continuum of pubertal development in childhood remains unclear. The purpose of this study was to determine the effects of self-reported dietary calcium intake and weight-bearing physical activity on bone mass accrual across the five stages of pubertal development in a large, diverse cohort of US children and adolescents. The Bone Mineral Density in Childhood study was a mixed longitudinal study with 7393 observations on 1743 subjects. Annually, we measured BMC by dual-energy X-ray absorptiometry (DXA), physical activity and calcium intake by questionnaire, and pubertal development (Tanner stage) by examination for up to 7 years. Mixed-effects regression models were used to assess physical activity and calcium intake effects on BMC accrual at each Tanner stage. We found that self-reported weight-bearing physical activity contributed to significantly greater BMC accrual in both sexes and racial subgroups (black and nonblack). In nonblack males, the magnitude of the activity effect on total body BMC accrual varied among Tanner stages after adjustment for calcium intake; the greatest difference between high- and low-activity boys was in Tanner stage 3. Calcium intake had a significant effect on bone accrual only in nonblack girls. This effect was not significantly different among Tanner stages. Our findings do not support differential effects of physical activity or calcium intake on bone mass accrual according to maturational stage. The study demonstrated significant longitudinal effects of weight-bearing physical activity on bone mass accrual through all stages of pubertal development.

  11. 29 CFR 2530.204-3 - Alternative computation methods for benefit accrual.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ADMINISTRATION, DEPARTMENT OF LABOR MINIMUM STANDARDS FOR EMPLOYEE PENSION BENEFIT PLANS UNDER THE EMPLOYEE... BENEFIT PLANS Participation, Vesting and Benefit Accrual § 2530.204-3 Alternative computation methods for..., a defined benefit pension plan may determine an employee's service for purposes of benefit...

  12. Accrual Patterns for Clinical Studies Involving Quantitative Imaging: Results of an NCI Quantitative Imaging Network (QIN) Survey

    PubMed Central

    Kurland, Brenda F.; Aggarwal, Sameer; Yankeelov, Thomas E.; Gerstner, Elizabeth R.; Mountz, James M.; Linden, Hannah M.; Jones, Ella F.; Bodeker, Kellie L.; Buatti, John M.

    2017-01-01

    Patient accrual is essential for the success of oncology clinical trials. Recruitment for trials involving the development of quantitative imaging biomarkers may face different challenges than treatment trials. This study surveyed investigators and study personnel for evaluating accrual performance and perceived barriers to accrual and for soliciting solutions to these accrual challenges that are specific to quantitative imaging-based trials. Responses for 25 prospective studies were received from 12 sites. The median percent annual accrual attained was 94.5% (range, 3%–350%). The most commonly selected barrier to recruitment (n = 11/25, 44%) was that “patients decline participation,” followed by “too few eligible patients” (n = 10/25, 40%). In a forced choice for the single greatest recruitment challenge, “too few eligible patients” was the most common response (n = 8/25, 32%). Quantitative analysis and qualitative responses suggested that interactions among institutional, physician, and patient factors contributed to accrual success and challenges. Multidisciplinary collaboration in trial design and execution is essential to accrual success, with attention paid to ensuring and communicating potential trial benefits to enrolled and future patients. PMID:28127586

  13. Financial Management Reforms in the Health Sector: A Comparative Study Between Cash-based and Accrual-based Accounting Systems

    PubMed Central

    Abolhallaje, Masoud; Jafari, Mehdi; Seyedin, Hesam; Salehi, Masoud

    2014-01-01

    Background: Financial management and accounting reform in the public sectors was started in 2000. Moving from cash-based to accrual-based is considered as the key component of these reforms and adjustments in the public sector. Performing this reform in the health system is a part of a bigger reform under the new public management. Objectives: The current study aimed to analyze the movement from cash-based to accrual-based accounting in the health sector in Iran. Patients and Methods: This comparative study was conducted in 2013 to compare financial management and movement from cash-based to accrual-based accounting in health sector in the countries such as the United States, Britain, Canada, Australia, New Zealand, and Iran. Library resources and reputable databases such as Medline, Elsevier, Index Copernicus, DOAJ, EBSCO-CINAHL and SID, and Iranmedex were searched. Fish cards were used to collect the data. Data were compared and analyzed using comparative tables. Results: Developed countries have implemented accrual-based accounting and utilized the valid, reliable and practical information in accrual-based reporting in different areas such as price and tariffs setting, operational budgeting, public accounting, performance evaluation and comparison and evidence based decision making. In Iran, however, only a few public organizations such as the municipalities and the universities of medical sciences use accrual-based accounting, but despite what is required by law, the other public organizations do not use accrual-based accounting. Conclusions: There are advantages in applying accrual-based accounting in the public sector which certainly depends on how this system is implemented in the sector. PMID:25763194

  14. Challenges Facing Early Phase Trials Sponsored by the National Cancer Institute: An Analysis of Corrective Action Plans to Improve Accrual.

    PubMed

    Massett, Holly A; Mishkin, Grace; Rubinstein, Larry; Ivy, S Percy; Denicoff, Andrea; Godwin, Elizabeth; DiPiazza, Kate; Bolognese, Jennifer; Zwiebel, James A; Abrams, Jeffrey S

    2016-11-15

    Accruing patients in a timely manner represents a significant challenge to early phase cancer clinical trials. The NCI Cancer Therapy Evaluation Program analyzed 19 months of corrective action plans (CAP) received for slow-accruing phase I and II trials to identify slow accrual reasons, evaluate whether proposed corrective actions matched these reasons, and assess the CAP impact on trial accrual, duration, and likelihood of meeting primary scientific objectives. Of the 135 CAPs analyzed, 69 were for phase I trials and 66 for phase II trials. Primary reasons cited for slow accrual were safety/toxicity (phase I: 48%), design/protocol concerns (phase I: 42%, phase II: 33%), and eligibility criteria (phase I: 41%, phase II: 35%). The most commonly proposed corrective actions were adding institutions (phase I: 43%, phase II: 85%) and amending the trial to change eligibility or design (phase I: 55%, phase II: 44%). Only 40% of CAPs provided proposed corrective actions that matched the reasons given for slow accrual. Seventy percent of trials were closed to accrual at time of analysis (phase I = 48; phase II = 46). Of these, 67% of phase I and 70% of phase II trials met their primary objectives, but they were active three times longer than projected. Among closed trials, 24% had an accrual rate increase associated with a greater likelihood of meeting their primary scientific objectives. Ultimately, trials receiving CAPs saw improved accrual rates. Future trials may benefit from implementing CAPs early in trial life cycles, but it may be more beneficial to invest in earlier accrual planning. Clin Cancer Res; 22(22); 5408-16. ©2016 AACRSee related commentary by Mileham and Kim, p. 5397.

  15. Warming-induced reduced peat accrual rates and potential C losses in Northern U.S

    NASA Astrophysics Data System (ADS)

    Fissore, C.; Nater, E. A.; Moskun, A.; Klein, A.; Le, T.

    2013-12-01

    Peatlands located at northern latitudes represent a sink of carbon (C) that is at risk of being lost to the atmosphere if current and expected changes in climate accelerate existing C stock decomposition rates. The extent of such potential loss is still unknown, but recent studies suggest that accrual rate of this critical C stock may be in decline due to more rapid decomposition of plant material reaching the soil. The consequences for our climate system can be significant. If large amounts of C currently ';locked' belowground in peatland ecosystems were to be decomposed and hence lost to the atmosphere, atmospheric concentration of CO2 would increase, causing further warming and hence even more rapid decomposition of peatland C. Our objective in this study is to investigate and compare past and more recent rates of C accrual in peatlands to determine if the rates of C accrual are declining. We collected intact frozen blocks of peat from three sites in Northern Minnesota and sectioned them into horizontal slices, which are being dated by 137Cs and 14C. Atmospheric concentrations of both 137Cs and 14C spiked in the 1960's due to nuclear bomb testing, leaving a ';signature' in organic matter (14C) and sediments (137Cs). The signal has steadily declined since that time. Detection of the signal in current soil samples will allow us to date the sample and consequently to measure the quantity of C accrued in the peat over various measured time intervals.

  16. A Sense of Urgency: Evaluating the Link between Clinical Trial Development Time and the Accrual Performance of CTEP-Sponsored Studies

    PubMed Central

    Cheng, Steven K.; Dietrich, Mary S.; Finnigan, Shanda; Dilts, David M.

    2010-01-01

    Purpose Post-activation barriers to oncology clinical trial accruals are well documented; however, potential barriers prior to trial opening are not. We investigate one such barrier: trial development time. Experimental Design National Cancer Institute Cancer Therapy Evaluation Program (CTEP)-sponsored trials for all therapeutic, non-pediatric Phase I, I/II, II, and III studies activated between 2000–2004 were investigated for an eight-year period (n=419). Successful trials were those achieving 100% of minimum accrual goal. Time to open a study was the calendar time from initial CTEP submission to trial activation. Multivariate logistic regression analysis was used to calculate unadjusted and adjusted odds ratios, controlling for study phase and size of expected accruals. Results 37.9 percent (n=221) of CTEP-approved oncology trials failed to attain the minimum accrual goals, with 70.8 percent (n=14) of Phase III trials resulting in poor accrual. A total of 16474 patients (42.5% of accruals) accrued to those studies that were unable to achieve the projected minimum accrual goal. Trials requiring less than 12 months development were significantly more likely to achieve accrual goals (odds ratio, 2.15; 95% CI, 1.29–3.57, P=0.003) than trials with the median development time of 12–18 months. Trials requiring a development time of greater than 24 months were significantly less likely of achieving accrual goals (odds ratio, 0.40; 95% CI, 0.20–0.78, P=0.011) than trials with the median development time. Conclusions A large percentage of oncology clinical trials do not achieve minimum projected accruals. Trial development time appears to be one important predictor of the likelihood of successfully achieving the minimum accrual goals. PMID:21062929

  17. Moisture and vegetation controls on decadal-scale accrual of soil organic carbon and total nitrogen in restored grasslands

    USGS Publications Warehouse

    O'Brien, S. L.; Jastrow, J.D.; Grimley, D.A.; Gonzalez-Meler, M. A.

    2010-01-01

    Revitalization of degraded landscapes may provide sinks for rising atmospheric CO2, especially in reconstructed prairies where substantial belowground productivity is coupled with large soil organic carbon (SOC) deficits after many decades of cultivation. The restoration process also provides opportunities to study the often-elusive factors that regulate soil processes. Although the precise mechanisms that govern the rate of SOC accrual are unclear, factors such as soil moisture or vegetation type may influence the net accrual rate by affecting the balance between organic matter inputs and decomposition. A resampling approach was used to assess the control that soil moisture and plant community type each exert on SOC and total nitrogen (TN) accumulation in restored grasslands. Five plots that varied in drainage were sampled at least four times over two decades to assess SOC, TN, and C4- and C3-derived C. We found that higher long-term soil moisture, characterized by low soil magnetic susceptibility, promoted SOC and TN accrual, with twice the SOC and three times the TN gain in seasonally saturated prairies compared with mesic prairies. Vegetation also influenced SOC and TN recovery, as accrual was faster in the prairies compared with C3-only grassland, and C4-derived C accrual correlated strongly to total SOC accrual but C3-C did not. High SOC accumulation at the surface (0-10 cm) combined with losses at depth (10-20 cm) suggested these soils are recovering the highly stratified profiles typical of remnant prairies. Our results suggest that local hydrology and plant community are critical drivers of SOC and TN recovery in restored grasslands. Because these factors and the way they affect SOC are susceptible to modification by climate change, we contend that predictions of the C-sequestration performance of restored grasslands must account for projected climatic changes on both soil moisture and the seasonal productivity of C4 and C3 plants. ?? 2009 Blackwell

  18. Sex differences in the rate of abdominal adipose accrual during adulthood: the Fels Longitudinal Study

    PubMed Central

    Whitaker, Kara M.; Choh, Audrey C.; Lee, Miryoung; Towne, Bradford; Czerwinski, Stefan A.; Demerath, Ellen W.

    2016-01-01

    Objectives The purpose of this analysis was to evaluate sex differences in the rate of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) accrual in adults. Secondary analyses examined differences in the rate of VAT and SAT accrual in pre-, peri-, and post-menopausal women. Subjects/Methods Participants were 472 (60% female) non-Hispanic whites, aged 18-84 years at baseline in whom abdominal VAT and SAT were assessed using multiple-image magnetic resonance imaging at two time points, with an average follow-up of 7.3 ± 2.6 years. Linear regression models were used to examine the effects of sex, baseline age and their interaction on rate of change per year in body composition measures (ΔBMI, ΔVAT, and ΔVAT/SAT ratio (ΔVSR)) independent of baseline body composition measures, visit year, income, marital status, physical activity, smoking and alcohol intake. Secondary analyses examined differences in rate of fat change by menopausal status (pre, peri, post). Results Levels of BMI, VAT, and VSR all increased over the 7 year period on average (p<.001); however, the change in BMI (mean ΔBMI = +0.5%) was far smaller than for VAT (mean ΔVAT= +6.8%), SAT (mean ΔSAT = +2.4%), and VSR (mean ΔVSR = +3.6%). ΔBMI, ΔVAT, and ΔSAT decreased linearly with age in both sexes (p<0.01), such that older individuals had lower rates of BMI, VAT, and SAT gain, and this deceleration in BMI, VAT, and SAT accrual was greater in men than women (p for interaction <0.05). ΔVSR did not vary with age in either sex, but remained higher in men than women throughout adulthood. There were no differences in rate of weight or fat gain by menopausal status after adjustment for age. Conclusions Men and women continue to accrue abdominal adiposity with age, but the rate of weight and fat gain decreases over time, particularly in men. PMID:27005404

  19. 5 CFR 630.301 - Annual leave accrual and accumulation-Senior Executive Service, Senior-Level, and Scientific and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...-Senior Executive Service, Senior-Level, and Scientific and Professional Employees. 630.301 Section 630... LEAVE Annual Leave § 630.301 Annual leave accrual and accumulation—Senior Executive Service, Senior... the full pay period, and who— (1) Holds a position in the Senior Executive Service (SES) which...

  20. 26 CFR 1.436-1 - Limits on benefits and benefit accruals under single employer defined benefit plans.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 5 2012-04-01 2011-04-01 true Limits on benefits and benefit accruals under single employer defined benefit plans. 1.436-1 Section 1.436-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Certain Stock Options § 1.436-1 Limits on benefits...

  1. 26 CFR 1.436-1 - Limits on benefits and benefit accruals under single employer defined benefit plans.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 5 2014-04-01 2014-04-01 false Limits on benefits and benefit accruals under single employer defined benefit plans. 1.436-1 Section 1.436-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Certain Stock Options § 1.436-1 Limits on benefits...

  2. Accrual and Recruitment Practices at Clinical and Translational Science Award (CTSA) Institutions: A Call for Expectations, Expertise, and Evaluation

    PubMed Central

    Kost, Rhonda G.; Mervin-Blake, Sabrena; Hallarn, Rose; Rathmann, Charles; Kolb, H. Robert; Himmelfarb, Cheryl Dennison; D’Agostino, Toni; Rubinstein, Eric P.; Dozier, Ann M.; Schuff, Kathryn G.

    2014-01-01

    Purpose To respond to increased public and programmatic demand to address underenrollment of clinical translational research studies, the authors examine participant recruitment practices at Clinical and Translational Science Award sites (CTSAs) and make recommendations for performance metrics and accountability. Method The CTSA Recruitment and Retention taskforce developed and, in 2010, invited representatives at 46 CTSAs to complete an online 48-question survey querying CTSA accrual and recruitment outcomes, practices, evaluation methods, policies, and perceived gaps in related knowledge/practice. Descriptive statistical and thematic analyses were conducted. Results Forty-six respondents representing 44 CTSAs completed the survey. Recruitment conducted by study teams was the most common practice reported (78–91%, by study type); 39% reported their institution offered recruitment services to investigators. Respondents valued study feasibility assessment as a successful practice (39%); their desired additional resources included feasibility assessments (49%) and participant registries (44%). None reported their institution systematically required justification of feasibility; some indicated relevant information was considered prior to IRB review (30%) or contract approval (22%). All respondents’ IRBs tracked study progress, but only 10% of respondents could report outcome data for timely accrual. Few reported written policies addressing poor accrual or provided data to support recruitment practice effectiveness. Conclusions Many CTSAs lack the necessary framework to support study accrual. Recommendations to enhance accrual include articulating institutional expectations and policy for routine recruitment planning; providing recruitment expertise to inform feasibility assessment and recruitment planning; and developing interdepartmental coordination and integrated informatics infrastructure to drive the conduct, evaluation, and improvement of recruitment

  3. Moisture and vegetation controls on decadal-scale accrual of soil organic carbon and total nitrogen in restored grasslands.

    SciTech Connect

    O'Brien, S. L.; Jastrow, J. D.; Grimley, D. A.; Gonzalez-Meler, M. A.

    2010-09-01

    Revitalization of degraded landscapes may provide sinks for rising atmospheric CO{sub 2}, especially in reconstructed prairies where substantial belowground productivity is coupled with large soil organic carbon (SOC) deficits after many decades of cultivation. The restoration process also provides opportunities to study the often-elusive factors that regulate soil processes. Although the precise mechanisms that govern the rate of SOC accrual are unclear, factors such as soil moisture or vegetation type may influence the net accrual rate by affecting the balance between organic matter inputs and decomposition. A resampling approach was used to assess the control that soil moisture and plant community type each exert on SOC and total nitrogen (TN) accumulation in restored grasslands. Five plots that varied in drainage were sampled at least four times over two decades to assess SOC, TN, and C{sub 4}- and C{sub 3}-derived C. We found that higher long-term soil moisture, characterized by low soil magnetic susceptibility, promoted SOC and TN accrual, with twice the SOC and three times the TN gain in seasonally saturated prairies compared with mesic prairies. Vegetation also influenced SOC and TN recovery, as accrual was faster in the prairies compared with C{sub 3}-only grassland, and C{sub 4}-derived C accrual correlated strongly to total SOC accrual but C{sub 3}-C did not. High SOC accumulation at the surface (0-10 cm) combined with losses at depth (10-20 cm) suggested these soils are recovering the highly stratified profiles typical of remnant prairies. Our results suggest that local hydrology and plant community are critical drivers of SOC and TN recovery in restored grasslands. Because these factors and the way they affect SOC are susceptible to modification by climate change, we contend that predictions of the C-sequestration performance of restored grasslands must account for projected climatic changes on both soil moisture and the seasonal productivity of C

  4. Heart Failure

    MedlinePlus

    ... version of this page please turn Javascript on. Heart Failure What is Heart Failure? In heart failure, the heart cannot pump enough ... failure often experience tiredness and shortness of breath. Heart Failure is Serious Heart failure is a serious and ...

  5. Bone mineral accrual across growth in a mixed-ethnic group of children: are Asian children disadvantaged from an early age?

    PubMed

    Burrows, Melonie; Baxter-Jones, Adam; Mirwald, Robert; Macdonald, Heather; McKay, Heather

    2009-05-01

    We investigated the contribution of ethnicity, physical activity, body composition, and calcium intake to bone accrual across 7 years of growth. We assessed 80 Caucasian and 74 Asian boys and 81 Caucasian and 64 Asian girls at baseline and retained 155 children across all 7 years. Ethnicity, physical activity, and calcium intake were assessed by questionnaire; fat mass, lean mass, and bone mineral content (BMC) of the whole body (WB), lumbar spine (LS), total proximal femur (PF(TOT)), and femoral neck (FN) were measured using DXA (Hologic QDR 4500). We aligned children on peak height velocity and utilized multilevel modeling to assess bone mineral accrual. Height and lean mass accounted for 51.8% and 44.1% of BMC accrual in children. There was a significant difference in physical activity, calcium intake, and lean mass between Asians and Caucasian boys and girls at baseline and conclusion (p < 0.05). In boys, physical activity and ethnicity significantly predicted BMC accrual at the FN. In girls, Asians had significantly lower PF(TOT) and FN BMC. Calcium was a significant predictor of WB BMC accrual in boys and girls. In conclusion, our findings highlight the importance of accounting for ethnicity in pediatric studies. Physical activity, dietary calcium, and lean mass positively influence bone accrual and are lower in Asian compared to Caucasian children from a very young age.

  6. An update on childhood bone health: mineral accrual, assessment and treatment

    PubMed Central

    Sopher, Aviva B.; Fennoy, Ilene; Oberfield, Sharon E.

    2015-01-01

    Purpose of Review To update the reader's knowledge about the factors that influence bone mineral accrual and to review the advances in the assessment of bone health and treatment of bone disorders. Recent Findings Maternal vitamin D status influences neonatal calcium levels, bone mineral density and bone size. In turn, bone mineral density z-score tends to track in childhood. These factors highlight the importance of bone health as early as fetal life. Dual-energy x-ray absorptiometry is the mainstay of clinical bone health assessment in this population due to the availability of appropriate reference data. Recently, more information has become available about assessment and treatment of bone disease in chronically ill pediatric patients. Summary Bone health must become a health focus starting prenatally in order to maximize peak bone mass and to prevent osteoporosis-related bone disease in adulthood. Vitamin D, calcium and weight-bearing activity are factors of key importance throughout childhood in achieving optimal bone health as bone mineral density z-score tracks through childhood and into adulthood. Recent updates of the International Society for Clinical Densitometry focus on the appropriate use of dual-energy x-ray absorptiometry in children of all ages, including children with chronic disease, and on the treatment of pediatric bone disease. PMID:25517023

  7. Adiposity and TV viewing are related to less bone accrual in young children

    PubMed Central

    Wosje, Karen S.; Khoury, Philip R.; Claytor, Randal P.; Copeland, Kristen A.; Kalkwarf, Heidi J.; Daniels, Stephen R.

    2008-01-01

    Objective To examine the relation between baseline fat mass and gain in bone area and bone mass in preschoolers studied prospectively for 4 y, with a focus on the role of physical activity and TV viewing. Study design Children were part of a longitudinal study in which measures of fat, lean and bone mass, height, weight, activity, and diet were taken every 4 months from ages 3 to 7 y. Activity was measured by accelerometer, and TV viewing by parent checklist. We included 214 children with total body dual energy x-ray absorptiometry (Hologic 4500A) scans at ages 3.5 and 7 y. Results Higher baseline fat mass was associated with smaller increases in bone area and bone mass over the next 3.5 y (p<0.001). More TV viewing was related to smaller gains in bone area and bone mass accounting for race, sex, and height. Activity by accelerometer was not associated with bone gains. Conclusions Adiposity and TV viewing are related to less bone accrual in preschoolers. PMID:18692201

  8. Placental calcium transporter (PMCA3) gene expression predicts intrauterine bone mineral accrual.

    PubMed

    Martin, R; Harvey, N C; Crozier, S R; Poole, J R; Javaid, M K; Dennison, E M; Inskip, H M; Hanson, M; Godfrey, K M; Cooper, C; Lewis, R

    2007-05-01

    Evidence is accruing that environmental exposures during critical periods of early development induce persisting changes in skeletal growth, and alter fracture risk in later life. We have previously demonstrated that placental calcium transport, partly determined by maternal 25-(OH) vitamin D status, may underlie this phenomenon. However, the precise relationship between expression of calcium transport proteins in the human placenta, and neonatal bone mineral accrual in the offspring, remains unknown. Tissue samples from 70 human placentae were fast frozen in liquid nitrogen and stored at -70 degrees C. A quantitative real time reverse transcriptase polymerase chain reaction was used to measure the mRNA expression of PMCA isoforms 1-4, using beta-actin as a control gene. Neonatal whole body bone area, mineral content and areal density (BA, BMC, BMD) were measured within 2 weeks of birth using DXA. PMCA3 mRNA expression predicted BA (r=0.28, p=0.02), BMC (r=0.25, p=0.04), placental weight (r=0.26, p=0.04) and birth weight (r=0.33, p=0.006) of the neonate. In a multivariate model, the relationship between placental PMCA3 expression and neonatal BMC was independent of maternal height, pre-pregnant fat stores, parity, physical activity, smoking, and calcium intake (p<0.05). Expression of the placental calcium transporter PMCA3 mRNA predicts neonatal whole body bone mineral content. This association may explain, in part, the mechanism whereby a mother's 25(OH)-vitamin D stores influence her offspring's bone mass.

  9. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation.

    PubMed

    Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan

    2014-02-01

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.

  10. Surpassing the Target: How a Recruitment Campaign Transformed the Participant Accrual Trajectory in the Epilepsy Phenome/Genome Project.

    PubMed

    McGovern, Kathleen; Karn, Catharine Freyer; Fox, Kristen

    2015-10-01

    Participant recruitment challenges pervade the majority of publicly funded clinical trials. However, little is known about methods for enhancing participant accrual. The Epilepsy Phenome/Genome Project (EPGP), a multicenter study funded by the National Institute of Neurological Disorders and Stroke (NINDS), aimed to enroll a total of 5,250 participants to better understand the genetic causes and phenotypic manifestations of epilepsy. However, similar to other trials, EPGP encountered recruitment challenges, and by the end of its first year, net enrollment was only 48% of the target for that time. To address this, EPGP established a National Participant Recruitment Campaign and began implementing and tracking the enrollment outcomes of a variety of proven and relatively novel recruitment methods. At the conclusion of the project, EPGP had successfully enrolled a total of 5,445 participants, thus surpassing its enrollment target. Data pertaining to EPGP's National Participant Recruitment Campaign was analyzed retrospectively, and the results are reported here, so that other multicenter trials may consider these methods in their recruitment planning and potentially avoid the costly repercussions of participant accrual issues.

  11. RADIATION DETECTOR

    DOEpatents

    Wilson, H.N.; Glass, F.M.

    1960-05-10

    A radiation detector of the type is described wherein a condenser is directly connected to the electrodes for the purpose of performing the dual function of a guard ring and to provide capacitance coupling for resetting the detector system.

  12. Quantification of in vivo progenitor mutation accrual with ultra-low error rate and minimal input DNA using SIP-HAVA-seq.

    PubMed

    Taylor, Pete H; Cinquin, Amanda; Cinquin, Olivier

    2016-11-01

    Assaying in vivo accrual of DNA damage and DNA mutations by stem cells and pinpointing sources of damage and mutations would further our understanding of aging and carcinogenesis. Two main hurdles must be overcome. First, in vivo mutation rates are orders of magnitude lower than raw sequencing error rates. Second, stem cells are vastly outnumbered by differentiated cells, which have a higher mutation rate-quantification of stem cell DNA damage and DNA mutations is thus best performed from small, well-defined cell populations. Here we report a mutation detection technique, based on the "duplex sequencing" principle, with an error rate below ∼10(-10) and that can start from as little as 50 pg DNA. We validate this technique, which we call SIP-HAVA-seq, by characterizing Caenorhabditis elegans germline stem cell mutation accrual and asking how mating affects that accrual. We find that a moderate mating-induced increase in cell cycling correlates with a dramatic increase in accrual of mutations. Intriguingly, these mutations consist chiefly of deletions in nonexpressed genes. This contrasts with results derived from mutation accumulation lines and suggests that mutation spectrum and genome distribution change with replicative age, chronological age, cell differentiation state, and/or overall worm physiological state. We also identify single-stranded gaps as plausible deletion precursors, providing a starting point to identify the molecular mechanisms of mutagenesis that are most active. SIP-HAVA-seq provides the first direct, genome-wide measurements of in vivo mutation accrual in stem cells and will enable further characterization of underlying mechanisms and their dependence on age and cell state.

  13. Nrf2 regulates mass accrual and the antioxidant endogenous response in bone differently depending on the sex and age

    PubMed Central

    Pellegrini, Gretel Gisela; Cregor, Meloney; McAndrews, Kevin; Morales, Cynthya Carolina; McCabe, Linda Doyle; McCabe, George P.; Peacock, Munro; Burr, David; Weaver, Connie; Bellido, Teresita

    2017-01-01

    Accumulation of reactive oxygen species (ROS) is an important pathogenic mechanism underling the loss of bone mass and strength with aging and other conditions leading to osteoporosis. The transcription factor erythroid 2-related factor2 (Nrf2) plays a central role in activating the cellular response to ROS. Here, we examined the endogenous response of bone regulated by Nrf2, and its relationship with bone mass and architecture in the male and female murine skeleton. Young (3 month-old) and old (15 month-old) Nrf2 knockout (KO) mice of either sex exhibited the expected reduction in Nrf2 mRNA expression compared to wild type (WT) littermates. Nrf2 deletion did not lead to compensatory increase in Nrf1 or Nrf3, other members of this transcription factor family; and instead, Nrf1 expression was lower in KO mice. Compared to the respective WT littermate controls, female KO mice, young and old, exhibited lower expression of both detoxifying and antioxidant enzymes; young male KO mice, displayed lower expression of detoxifying enzymes but not antioxidant enzymes; and old male KO mice showed no differences in either detoxifying or antioxidant enzymes. Moreover, old male WT mice exhibited lower Nrf2 levels, and consequently lower expression of both detoxifying and antioxidant enzymes, compared to old female WT mice. These endogenous antioxidant responses lead to delayed rate of bone acquisition in female KO mice and higher bone acquisition in male KO mice as quantified by DXA and μCT, demonstrating that Nrf2 is required for full bone accrual in the female skeleton but unnecessary and even detrimental in the male skeleton. Therefore, Nrf2 regulates the antioxidant endogenous response and bone accrual differently depending on sex and age. These findings suggest that therapeutic interventions that target Nrf2 could be developed to enhance the endogenous antioxidant response in a sex- and age-selective manner. PMID:28152064

  14. Challenges and Potential Solutions to Meeting Accrual Goals in a Phase II Chemoprevention Trial for Prostate Cancer

    PubMed Central

    Kumar, Nagi; Crocker, Theresa; Smith, Tiffany; Pow-Sang, Julio; Spiess, Philippe E.; Egan, Kathleen; Quinn, Gwen; Schell, Michael; Sebti, Said; Kazi, Aslam; Chuang, Tian; Salup, Raoul; Helal, Mohamed; Zagaja, Gregory; Trabulsi, Edouard; McLarty, Jerry; Fazili, Tajammul; Williams, Christopher R.; Schreiber, Fred; Slaton, Joel; Anderson, J Kyle

    2011-01-01

    Objective The goal of this report is to describe the on going strategies, successes, challenges and solutions for recruitment in this multi-center, phase II chemoprevention trial targeting men at high risk for prostate cancer. Methods We developed and implemented a multi-center clinical trial in institutions with supportive infrastructure, lead by a recruitment team of experienced and committed physicians and clinical trial staff, implementing multi-media and community outreach strategies to meet recruitment goals. Screening logs were reviewed to identify trends as well as patient, protocol and infrastructure -related barriers impacting accrual and revisions to protocol implemented. Results Between January 2008 and February 2011 a total of 3547 individuals were prescreened with 94% (n=3092) determined to be ineligible based on diagnosis of cancer or benign biopsy results. Of these, 216 were considered eligible for further screening with 52% (n=113) declining to participate due to patient related factors and 14% (n=29) eliminated due to protocol-related criteria for exclusion. Ninety four (94) subjects consented to participate with 34% of these subjects (n=74) meeting all eligibility criteria to be randomized to receive study agent or placebo. Across all sites, 99% of the recruitment of subjects in this clinical trial is via physician recruitment and referral with less than 1% responding to other recruitment strategies. Conclusion A contemporary approach to subject recruitment and frequent evaluation is needed to assure responsiveness to emerging challenges to accrual and the evolving scientific literature. A focus on investing on improving systems for physician recruitment may be key to meeting recruitment target in chemoprevention trials. PMID:22101219

  15. BURNOUT RESISTANT X-BAND HOT CARRIER DETECTORS.

    DTIC Science & Technology

    DETECTORS, *FAILURE(ELECTRONICS), SEMICONDUCTOR DIODES, X BAND, VOLTAGE, SILICON, DIOXIDES, SEEBECK EFFECT , CHARGE CARRIERS, PALLADIUM ALLOYS, ELECTRICAL RESISTANCE, GALLIUM ALLOYS, ARSENIDES, DIELECTRICS, RECTIFIERS, VIDEO AMPLIFIERS.

  16. Smoke Detector

    NASA Technical Reports Server (NTRS)

    1979-01-01

    In the photo, Fire Chief Jay Stout of Safety Harbor, Florida, is explaining to young Richard Davis the workings of the Honeywell smoke and fire detector which probably saved Richard's life and that of his teen-age brother. Alerted by the detector's warning, the pair were able to escape their burning home. The detector in the Davis home was one of 1,500 installed in Safety Harbor residences in a cooperative program conducted by the city and Honeywell Inc.

  17. Ignition-Spark Detector for Engine Testing

    NASA Technical Reports Server (NTRS)

    Kuhr, G.

    1985-01-01

    Optical fiber views sparks directly. In fuel or oxidizer tube, optical fiber collects light from ignition spark. Fibers also used to collect light from combustion reactions for spectrographic analysis. Useful in engine testing, detector helps determine reason for engine failure.

  18. Respiratory Failure

    MedlinePlus

    Respiratory failure happens when not enough oxygen passes from your lungs into your blood. Your body's organs, ... brain, need oxygen-rich blood to work well. Respiratory failure also can happen if your lungs can' ...

  19. Heart Failure

    MedlinePlus

    Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... Tiredness and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...

  20. Metal Detectors.

    ERIC Educational Resources Information Center

    Harrington-Lueker, Donna

    1992-01-01

    Schools that count on metal detectors to stem the flow of weapons into the schools create a false sense of security. Recommendations include investing in personnel rather than hardware, cultivating the confidence of law-abiding students, and enforcing discipline. Metal detectors can be quite effective at afterschool events. (MLF)

  1. Myelitis in systemic lupus erythematosus: clinical characteristics and effect in accrual damage. A single-center experience.

    PubMed

    Quintanilla-González, L; Atisha-Fregoso, Y; Llorente, L; Fragoso-Loyo, H

    2017-03-01

    Objective The purpose of this study was to describe the clinical characteristics of acute transverse myelitis, including the time of their presentation, and to evaluate their effect on accrual damage in patients with systemic lupus erythematosus (SLE). Methods Patients with SLE who were hospitalized because of incident, noninfectious myelitis at our institute between January 1997 and December 2013 were identified. As a control group, we selected for each of the patients in the study group one SLE patient hospitalized at the closest date to the case due to other severe non-neuropsychiatric (NP) SLE manifestation, with no history of NP manifestations or noninfectious disease. Clinical characteristics, laboratory results, treatment, disease activity (SLEDAI-2K), and damage (SLICC/ACR-DI) were collected from medical charts at the index hospitalization and one year after hospitalization. Results Demographics and SLE characteristics, including age at SLE diagnosis and time since SLE diagnosis to hospitalization, were comparable in patients with myelitis and controls. At hospitalization, disease activity and cumulative damage were similar in both groups. Patients with myelitis received more aggressive treatment than controls. One year after hospitalization, two of the 15 patients who completed follow-up had symptom improvement without neurologic sequelae, and 13 of them had some improvement of symptoms with neurologic sequelae. Four patients died in the myelitis group, three of them of infectious diseases, and one of alveolar hemorrhage. No patient died because of myelopathy and in the control group no patient died, although three were lost during the follow-up. Disease activity and treatment did not differ between both groups. However, cumulative damage was higher among the patients with myelitis than controls (1.9 ± 0.9 vs 0.75 ± 0.9; p = 0.003). Conclusion Patients with myelitis have clinical characteristics similar to those observed in non-NP SLE and

  2. Gaseous Detectors

    NASA Astrophysics Data System (ADS)

    Titov, Maxim

    Since long time, the compelling scientific goals of future high-energy physics experiments were a driving factor in the development of advanced detector technologies. A true innovation in detector instrumentation concepts came in 1968, with the development of a fully parallel readout for a large array of sensing elements - the Multi-Wire Proportional Chamber (MWPC), which earned Georges Charpak a Nobel prize in physics in 1992. Since that time radiation detection and imaging with fast gaseous detectors, capable of economically covering large detection volumes with low mass budget, have been playing an important role in many fields of physics. Advances in photolithography and microprocessing techniques in the chip industry during the past decade triggered a major transition in the field of gas detectors from wire structures to Micro-Pattern Gas Detector (MPGD) concepts, revolutionizing cell-size limitations for many gas detector applications. The high radiation resistance and excellent spatial and time resolution make them an invaluable tool to confront future detector challenges at the next generation of colliders. The design of the new micro-pattern devices appears suitable for industrial production. Novel structures where MPGDs are directly coupled to the CMOS pixel readout represent an exciting field allowing timing and charge measurements as well as precise spatial information in 3D. Originally developed for the high-energy physics, MPGD applications have expanded to nuclear physics, photon detection, astroparticle and neutrino physics, neutron detection, and medical imaging.

  3. Recombinant growth hormone enhances muscle myosin heavy-chain mRNA accumulation and amino acid accrual in humans.

    PubMed

    Fong, Y; Rosenbaum, M; Tracey, K J; Raman, G; Hesse, D G; Matthews, D E; Leibel, R L; Gertner, J M; Fischman, D A; Lowry, S F

    1989-05-01

    A potentially lethal complication of trauma, malignancy, and infection is a progressive erosion of muscle protein mass that is not readily reversed by nutritional support. Growth hormone is capable of improving total body nitrogen balance, but its role in myofibrillar protein synthesis in humans is unknown. The acute, in situ muscle protein response to an infusion of methionyl human growth hormone was investigated in the limbs of nutritionally depleted subjects during a period of intravenous refeeding. A 6-hr methionyl growth hormone infusion achieved steady-state serum levels comparable to normal physiologic peaks and was associated with a significant increase in limb amino acid uptake, without a change in body amino acid oxidation. Myosin heavy-chain mRNA levels, measured by quantitative dot blot hybridization, were also significantly elevated after growth hormone administration. The data indicate that methionyl growth hormone can induce intracellular amino acid accrual and increased levels of myofibrillar protein mRNA during hospitalized nutritional support and suggest growth hormone to be a potential therapy of lean body wasting.

  4. Chemochromic Hydrogen Leak Detectors

    NASA Technical Reports Server (NTRS)

    Roberson, Luke; Captain, Janine; Williams, Martha; Smith, Trent; Tate, LaNetra; Raissi, Ali; Mohajeri, Nahid; Muradov, Nazim; Bokerman, Gary

    2009-01-01

    At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or

  5. MS Detectors

    SciTech Connect

    Koppenaal, David W.; Barinaga, Charles J.; Denton, M Bonner B.; Sperline, Roger P.; Hieftje, Gary M.; Schilling, G. D.; Andrade, Francisco J.; Barnes IV., James H.

    2005-11-01

    Good eyesight is often taken for granted, a situation that everyone appreciates once vision begins to fade with age. New eyeglasses or contact lenses are traditional ways to improve vision, but recent new technology, i.e. LASIK laser eye surgery, provides a new and exciting means for marked vision restoration and improvement. In mass spectrometry, detectors are the 'eyes' of the MS instrument. These 'eyes' have also been taken for granted. New detectors and new technologies are likewise needed to correct, improve, and extend ion detection and hence, our 'chemical vision'. The purpose of this report is to review and assess current MS detector technology and to provide a glimpse towards future detector technologies. It is hoped that the report will also serve to motivate interest, prompt ideas, and inspire new visions for ion detection research.

  6. Detectors for the SIMURIS payload

    NASA Astrophysics Data System (ADS)

    Patchett, B. E.; Carter, M. K.; Read, P. D.

    1992-05-01

    Detectors for the Solar Ultraviolet Network (SUN) and Imaging Fourier Transform Spectrometer (IFTS) instruments, which are particularly challenging due to the requirements for high total count rate, high pixel count rate, and far UV sensitivity, are discussed. Count rates are exceptionally high for active regions, but with a spatial resolution of 0.001 inches it is also possible that high individual pixel counts will occur even on 'quiet' Sun observations. On the other hand it is planned to use the Solar Interferometric Mission for Ultrahigh Resolution Imaging and Spectroscopy (SIMURIS) for planetary observations where the detectors will be required to work efficiently and with very low noise levels. It seems unlikely that any one detector would suffice for all channels, and in any case this could potentially represent a single point of failure. The design and performance of a range of modular detectors which are built specifically with solar UV observing in mind are discussed along with plans for their future development.

  7. Failure Scenarios and Mitigations for the BABAR Superconducting Solenoid

    NASA Astrophysics Data System (ADS)

    Thompson, EunJoo; Candia, A.; Craddock, W. W.; Racine, M.; Weisend, J. G.

    2006-04-01

    The cryogenic department at the Stanford Linear Accelerator Center is responsible for the operation, troubleshooting, and upgrade of the 1.5 Tesla superconducting solenoid detector for the BABAR B-factory experiment. Events that disable the detector are rare but significantly impact the availability of the detector for physics research. As a result, a number of systems and procedures have been developed over time to minimize the downtime of the detector, for example improved control systems, improved and automatic backup systems, and spares for all major components. Together they can prevent or mitigate many of the failures experienced by the utilities, mechanical systems, controls and instrumentation. In this paper we describe various failure scenarios, their effect on the detector, and the modifications made to mitigate the effects of the failure. As a result of these modifications the reliability of the detector has increased significantly with only 3 shutdowns of the detector due to cryogenics systems over the last 2 years.

  8. Photon detectors

    SciTech Connect

    Va`vra, J.

    1995-10-01

    J. Seguinot and T. Ypsilantis have recently described the theory and history of Ring Imaging Cherenkov (RICH) detectors. In this paper, I will expand on these excellent review papers, by covering the various photon detector designs in greater detail, and by including discussion of mistakes made, and detector problems encountered, along the way. Photon detectors are among the most difficult devices used in physics experiments, because they must achieve high efficiency for photon transport and for the detection of single photo-electrons. For gaseous devices, this requires the correct choice of gas gain in order to prevent breakdown and wire aging, together with the use of low noise electronics having the maximum possible amplification. In addition, the detector must be constructed of materials which resist corrosion due to photosensitive materials such as, the detector enclosure must be tightly sealed in order to prevent oxygen leaks, etc. The most critical step is the selection of the photocathode material. Typically, a choice must be made between a solid (CsI) or gaseous photocathode (TMAE, TEA). A conservative approach favors a gaseous photocathode, since it is continuously being replaced by flushing, and permits the photon detectors to be easily serviced (the air sensitive photocathode can be removed at any time). In addition, it can be argued that we now know how to handle TMAE, which, as is generally accepted, is the best photocathode material available as far as quantum efficiency is concerned. However, it is a very fragile molecule, and therefore its use may result in relatively fast wire aging. A possible alternative is TEA, which, in the early days, was rejected because it requires expensive CaF{sub 2} windows, which could be contaminated easily in the region of 8.3 eV and thus lose their UV transmission.

  9. Long-term organ damage accrual and safety in patients with SLE treated with belimumab plus standard of care

    PubMed Central

    Urowitz, M; van Vollenhoven, R; Aranow, C; Fettiplace, J; Oldham, M; Wilson, B; Molta, C; Roth, D; Gordon, D

    2016-01-01

    -term belimumab plus SoC had a low incidence of organ damage accrual and no unexpected AEs. High-risk patients with pre-existing organ damage also had low accrual, suggesting a favorable effect on future damage development. PMID:26936891

  10. Intruder Detector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The shadowy prowler is attempting a break-in, unaware that his presence has already been detected and reported by the device in the lower left corner of the photo. It is part of a three-element ntruder Detecti on System developed by NASA's Ames Research Center from technology acquired in the Apollo lunar exploration program. Apollo astronauts left behind on the moon small portable seismic (shock) detectors to record subsurface vibrations and transmit to Earth data on the moon's density and thickness. A similar seismic detector is the key component of the lntruder Detection System. Encased in a stainless steel tube, the detector is implanted in the ground outside the facility being protected-home, bank, industrial or other facilities. The vibration-sensing detector picks up the footstep of anyone within a preset range. The detector is connected by cable to the transmitter, which relays the warning to a portable radio receiver. The radio alerts plant guards or home occupants by emitting an audible tone burst for each footstep.

  11. Pyroelectric detectors

    NASA Technical Reports Server (NTRS)

    Haller, Eugene E.; Beeman, Jeffrey; Hansen, William L.; Hubbard, G. Scott; Mcmurray, Robert E., Jr.

    1990-01-01

    The multi-agency, long-term Global Change programs, and specifically NASA's Earth Observing system, will require some new and advanced photon detector technology which must be specifically tailored for long-term stability, broad spectral range, cooling constraints, and other parameters. Whereas MCT and GaAs alloy based photovoltaic detectors and detector arrays reach most impressive results to wavelengths as long as 12 microns when cooled to below 70 K, other materials, such as ferroelectrics and pyroelectrics, appear to offer special opportunities beyond 12 microns and above 70 K. These materials have found very broad use in a wide variety of room temperature applications. Little is known about these classes of materials at sub-room temperatures and no photon detector results have been reported. From the limited information available, researchers conclude that the room temperature values of D asterisk greater than or equal to 10(exp 9) cm Hz(exp 1/2)/W may be improved by one to two orders of magnitude upon cooling to temperatures around 70 K. Improvements of up to one order of magnitude appear feasible for temperatures achievable by passive cooling. The flat detector response over a wavelength range reaching from the visible to beyond 50 microns, which is an intrinsic advantage of bolometric devices, makes for easy calibration. The fact that these materials have been developed for reduced temperature applications makes ferro- and pyroelectric materials most attractive candidates for serious exploration.

  12. MAMA Detector

    NASA Technical Reports Server (NTRS)

    Bowyer, Stuart

    1998-01-01

    Work carried out under this grant led to fundamental discoveries and over one hundred publications in the scientific literature. Fundamental developments in instrumentation were made including all the instrumentation on the EUVE satellite, the invention of a whole new type of grazing instrument spectrometer and the development of fundamentally new photon counting detectors including the Wedge and Strip used on EUVE and many other missions and the Time Delay detector used on OREFUS and FUSE. The Wedge and Strip and Time Delay detectors were developed under this grant for less than two million dollars and have been used in numerous missions most recently for the FUSE mission. In addition, a fundamentally new type of diffuse spectrometer has been developed under this grant which has been used in instrumentation on the MMSAT spacecraft and the Lewis spacecraft. Plans are underway to use this instrumentation on several other missions as well.

  13. PHASE DETECTOR

    DOEpatents

    Kippenhan, D.O.

    1959-09-01

    A phase detector circuit is described for use at very high frequencies of the order of 50 megacycles. The detector circuit includes a pair of rectifiers inverted relative to each other. One voltage to be compared is applied to the two rectifiers in phase opposition and the other voltage to be compared is commonly applied to the two rectifiers. The two result:ng d-c voltages derived from the rectifiers are combined in phase opposition to produce a single d-c voltage having amplitude and polarity characteristics dependent upon the phase relation between the signals to be compared. Principal novelty resides in the employment of a half-wave transmission line to derive the phase opposing signals from the first voltage to be compared for application to the two rectifiers in place of the transformer commonly utilized for such purpose in phase detector circuits for operation at lower frequency.

  14. Hydrogen detector

    DOEpatents

    Kanegae, Naomichi; Ikemoto, Ichiro

    1980-01-01

    A hydrogen detector of the type in which the interior of the detector is partitioned by a metal membrane into a fluid section and a vacuum section. Two units of the metal membrane are provided and vacuum pipes are provided independently in connection to the respective units of the metal membrane. One of the vacuum pipes is connected to a vacuum gauge for static equilibrium operation while the other vacuum pipe is connected to an ion pump or a set of an ion pump and a vacuum gauge both designed for dynamic equilibrium operation.

  15. Microwave detector

    SciTech Connect

    Meldner, H.W.; Cusson, R.Y.; Johnson, R.M.

    1986-12-02

    A detector is described for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations, the detector comprising: a B-dot loop linking the magnetic field of the microwave pulse; a biased ferrite, that produces a magnetization field flux that links the B-dot loop. The ferrite is positioned within the B-dot loop so that the magnetic field of the microwave pulse interacts with the ferrite and thereby participates in the formation of the magnetization field flux; and high-frequency insensitive means for measuring electric voltage or current induced in the B-dot loop.

  16. Microwave detector

    DOEpatents

    Meldner, H.W.; Cusson, R.Y.; Johnson, R.M.

    1985-02-08

    A microwave detector is provided for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations. A biased ferrite produces a magnetization field flux that links a B-dot loop. The magnetic field of the microwave pulse participates in the formation of the magnetization field flux. High-frequency insensitive means are provided for measuring electric voltage or current induced in the B-dot loop. The recorded output of the detector is proportional to the time derivative of the square of the envelope shape of the microwave pulse.

  17. Microwave detector

    DOEpatents

    Meldner, Heiner W.; Cusson, Ronald Y.; Johnson, Ray M.

    1986-01-01

    A microwave detector (10) is provided for measuring the envelope shape of a microwave pulse comprised of high-frequency oscillations. A biased ferrite (26, 28) produces a magnetization field flux that links a B-dot loop (16, 20). The magnetic field of the microwave pulse participates in the formation of the magnetization field flux. High-frequency insensitive means (18, 22) are provided for measuring electric voltage or current induced in the B-dot loop. The recorded output of the detector is proportional to the time derivative of the square of the envelope shape of the microwave pulse.

  18. Silicon Detectors

    NASA Astrophysics Data System (ADS)

    Sadrozinski, Hartmut

    2014-03-01

    The use of silicon detectors has experienced an exponential growth in accelerator and space based experiments, similar to trends in the semiconductor industry as a whole, usually paraphrased as ``Moore's Law.'' Some of the essentials for this phenomenon will be presented, together with examples of the exciting science results which it enabled. With the establishment of a ``semiconductor culture'' in universities and laboratories around the world, an increased understanding of the sensors results in thinner, faster, more radiation-resistant detectors, spawning an amazing wealth of new technologies and applications, which will be the main subject of the presentation.

  19. Kidney Failure

    MedlinePlus

    ... Dialysis or Transplant Paying for Kidney Failure Treatment Contact Us Health Information Center Phone: 1-800-860- ... to share this content freely. October 2, 2013 Contact Us Health Information Center Phone: 1-800-860- ...

  20. Heart Failure

    MedlinePlus

    ... for people who can't tolerate ACE inhibitors. Beta blockers. This class of drugs not only slows your ... rhythms and lessen your chance of dying unexpectedly. Beta blockers may reduce signs and symptoms of heart failure, ...

  1. Vertex detectors

    SciTech Connect

    Lueth, V.

    1992-07-01

    The purpose of a vertex detector is to measure position and angles of charged particle tracks to sufficient precision so as to be able to separate tracks originating from decay vertices from those produced at the interaction vertex. Such measurements are interesting because they permit the detection of weakly decaying particles with lifetimes down to 10{sup {minus}13} s, among them the {tau} lepton and charm and beauty hadrons. These two lectures are intended to introduce the reader to the different techniques for the detection of secondary vertices that have been developed over the past decades. The first lecture includes a brief introduction to the methods used to detect secondary vertices and to estimate particle lifetimes. It describes the traditional technologies, based on photographic recording in emulsions and on film of bubble chambers, and introduces fast electronic registration of signals derived from scintillating fibers, drift chambers and gaseous micro-strip chambers. The second lecture is devoted to solid state detectors. It begins with a brief introduction into semiconductor devices, and then describes the application of large arrays of strip and pixel diodes for charged particle tracking. These lectures can only serve as an introduction the topic of vertex detectors. Time and space do not allow for an in-depth coverage of many of the interesting aspects of vertex detector design and operation.

  2. A preliminary evaluation of a failure detection filter for detecting and identifying control element failures in a transport aircraft

    NASA Technical Reports Server (NTRS)

    Bundick, W. T.

    1985-01-01

    The application of the failure detection filter to the detection and identification of aircraft control element failures was evaluated in a linear digital simulation of the longitudinal dynamics of a B-737 Aircraft. Simulation results show that with a simple correlator and threshold detector used to process the filter residuals, the failure detection performance is seriously degraded by the effects of turbulence.

  3. Heart failure

    PubMed Central

    2011-01-01

    Introduction Heart failure occurs in 3% to 4% of adults aged over 65 years, usually as a consequence of coronary artery disease or hypertension, and causes breathlessness, effort intolerance, fluid retention, and increased mortality. The 5-year mortality in people with systolic heart failure ranges from 25% to 75%, often owing to sudden death following ventricular arrhythmia. Risks of cardiovascular events are increased in people with left ventricular systolic dysfunction (LVSD) or heart failure. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of multidisciplinary interventions for heart failure? What are the effects of exercise in people with heart failure? What are the effects of drug treatments for heart failure? What are the effects of devices for treatment of heart failure? What are the effects of coronary revascularisation for treatment of heart failure? What are the effects of drug treatments in people at high risk of heart failure? What are the effects of treatments for diastolic heart failure? We searched: Medline, Embase, The Cochrane Library, and other important databases up to August 2010 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: aldosterone receptor antagonists, amiodarone, angiotensin-converting enzyme inhibitors, angiotensin II receptor blockers, anticoagulation, antiplatelet agents, beta-blockers, calcium

  4. Flame Detector

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Scientific Instruments, Inc. has now developed a second generation, commercially available instrument to detect flames in hazardous environments, typically refineries, chemical plants and offshore drilling platforms. The Model 74000 detector incorporates a sensing circuit that detects UV radiation in a 100 degree conical field of view extending as far as 250 feet from the instrument. It operates in a bandwidth that makes it virtually 'blind' to solar radiation while affording extremely high sensitivity to ultraviolet flame detection. A 'windowing' technique accurately discriminates between background UV radiation and ultraviolet emitted from an actual flame, hence the user is assured of no false alarms. Model 7410CP is a combination controller and annunciator panel designed to monitor and control as many as 24 flame detectors. *Model 74000 is no longer being manufactured.

  5. Neutron detector

    DOEpatents

    Stephan, Andrew C.; Jardret; Vincent D.

    2011-04-05

    A neutron detector has a volume of neutron moderating material and a plurality of individual neutron sensing elements dispersed at selected locations throughout the moderator, and particularly arranged so that some of the detecting elements are closer to the surface of the moderator assembly and others are more deeply embedded. The arrangement captures some thermalized neutrons that might otherwise be scattered away from a single, centrally located detector element. Different geometrical arrangements may be used while preserving its fundamental characteristics. Different types of neutron sensing elements may be used, which may operate on any of a number of physical principles to perform the function of sensing a neutron, either by a capture or a scattering reaction, and converting that reaction to a detectable signal. High detection efficiency, an ability to acquire spectral information, and directional sensitivity may be obtained.

  6. Angle detector

    NASA Technical Reports Server (NTRS)

    Parra, G. T. (Inventor)

    1978-01-01

    An angle detector for determining a transducer's angular disposition to a capacitive pickup element is described. The transducer comprises a pendulum mounted inductive element moving past the capacitive pickup element. The capacitive pickup element divides the inductive element into two parts L sub 1 and L sub 2 which form the arms of one side of an a-c bridge. Two networks R sub 1 and R sub 2 having a plurality of binary weighted resistors and an equal number of digitally controlled switches for removing resistors from the networks form the arms of the other side of the a-c bridge. A binary counter, controlled by a phase detector, balances the bridge by adjusting the resistance of R sub 1 and R sub 2. The binary output of the counter is representative of the angle.

  7. Neutrino Detectors

    NASA Astrophysics Data System (ADS)

    von Feilitzsch, Franz; Lanfranchi, Jean-Côme; Wurm, Michael

    The neutrino was postulated by Wolfgang Pauli in the early 1930s, but could only be detected for the first time in the 1950s. Ever since scientists all around the world have worked on the detection and understanding of this particle which so scarcely interacts with matter. Depending on the origin and nature of the neutrino, various types of experiments have been developed and operated. In this entry, we will review neutrino detectors in terms of neutrino energy and associated detection technique as well as the scientific outcome of some selected examples. After a brief historical introduction, the detection of low-energy neutrinos originating from nuclear reactors or from the Earth is used to illustrate the principles and difficulties which are encountered in detecting neutrinos. In the context of solar neutrino spectroscopy, where the neutrino is used as a probe for astrophysics, three different types of neutrino detectors are presented - water Čerenkov, radiochemical, and liquid-scintillator detectors. Moving to higher neutrino energies, we discuss neutrinos produced by astrophysical sources and from accelerators. The entry concludes with an overview of a selection of future neutrino experiments and their scientific goals.

  8. Heart failure

    PubMed Central

    2010-01-01

    Introduction Heart failure occurs in 3% to 4% of adults aged over 65 years, usually as a consequence of coronary artery disease or hypertension, and causes breathlessness, effort intolerance, fluid retention, and increased mortality. The 5-year mortality in people with systolic heart failure ranges from 25% to 75%, often owing to sudden death following ventricular arrhythmia. Risks of cardiovascular events are increased in people with left ventricular systolic dysfunction (LVSD) or heart failure. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of non-drug treatments, and of drug and invasive treatments, for heart failure? What are the effects of angiotensin-converting enzyme inhibitors in people at high risk of heart failure? What are the effects of treatments for diastolic heart failure? We searched: Medline, Embase, The Cochrane Library, and other important databases up to May 2009 (Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 85 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: aldosterone receptor antagonists, amiodarone, angiotensin-converting enzyme inhibitors, angiotensin II receptor blockers, anticoagulation, antiplatelet agents, beta-blockers, calcium channel blockers, cardiac resynchronisation therapy, digoxin (in people already receiving diuretics and angiotensin-converting enzyme inhibitors), exercise, hydralazine plus isosorbide dinitrate, implantable cardiac

  9. Kidney (Renal) Failure

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Kidney Failure Kidney failure, also known as renal failure, ... evaluated? How is kidney failure treated? What is kidney (renal) failure? The kidneys are designed to maintain ...

  10. Oscillator detector

    SciTech Connect

    Potter, B.M.

    1980-05-13

    An alien liquid detector employs a monitoring element and an oscillatory electronic circuit for maintaining the temperature of the monitoring element substantially above ambient temperature. The output wave form, eg., frequency of oscillation or wave shape, of the oscillatory circuit depends upon the temperaturedependent electrical characteristic of the monitoring element. A predetermined change in the output waveform allows water to be discriminated from another liquid, eg., oil. Features of the invention employing two thermistors in two oscillatory circuits include positioning one thermistor for contact with water and the other thermistor above the oil-water interface to detect a layer of oil if present. Unique oscillatory circuit arrangements are shown that achieve effective thermistor action with an economy of parts and energizing power. These include an operational amplifier employed in an astable multivibrator circuit, a discrete transistor-powered tank circuit, and use of an integrated circuit chip.

  11. Balancing high accrual and ethical recruitment in paediatric oncology: a qualitative study of the 'look and feel' of clinical trial discussions

    PubMed Central

    2010-01-01

    Background High accrual to clinical trials enables new treatment strategies to be tested rapidly, accurately and with generalisability. Ethical standards also must be high so that participation is voluntary and informed. However, this can be difficult to achieve in trials with complex designs and in those which are closely embedded in clinical practice. Optimal recruitment requires a balance of both ethical and accrual considerations. In the context of a trial of stratified treatments for children with acute lymphoblastic leukaemia (UKALL2003) we examined how recruitment looked to an observer and how it felt to the parents, to identify how doctors' communication could promote or inhibit optimal recruitment. Methods We audio-recorded, transcribed and analysed routine doctor-patient consultations (n = 20) and interviews between researchers and parents (n = 30 parents) across six UK treatment centres. Analysis was informed by the constant comparative method. For consultation transcripts, analysis focussed on how doctors presented the trial. We compared this with analysis of the interview transcripts which focussed on parents' perceptions and understanding of the trial. Results Parents and doctors discussed the trial in most consultations, even those that did not involve a decision about randomisation. Doctors used language allying them both with the trial and with the parent, indicating that they were both an 'investigator' and a 'clinician'. They presented the trial both as an empirical study with a scientific imperative and also as offering personalisation of treatment for the child. Parents appeared to understand that trial involvement was voluntary, that it was different from routine care and that they could withdraw from the trial at any time. Some were confused about the significance of the MRD test and the personalisation of treatment. Conclusions Doctors communicated in ways that generally promoted optimal recruitment, indicating that trials can be embedded

  12. Heart failure.

    PubMed

    Braunwald, Eugene

    2013-02-01

    Despite major improvements in the treatment of virtually all cardiac disorders, heart failure (HF) is an exception, in that its prevalence is rising, and only small prolongations in survival are occurring. An increasing fraction, especially older women with diabetes, obesity, and atrial fibrillation exhibit HF with preserved systolic function. Several pathogenetic mechanisms appear to be operative in HF. These include increased hemodynamic overload, ischemia-related dysfunction, ventricular remodeling, excessive neurohumoral stimulation, abnormal myocyte calcium cycling, excessive or inadequate proliferation of the extracellular matrix, accelerated apoptosis, and genetic mutations. Biomarkers released as a consequence of myocardial stretch, imbalance between formation and breakdown of extracellular matrix, inflammation, and renal failure are useful in the identification of the pathogenetic mechanism and, when used in combination, may become helpful in estimating prognosis and selecting appropriate therapy. Promising new therapies that are now undergoing intensive investigation include an angiotensin receptor neprilysin inhibitor, a naturally-occurring vasodilator peptide, a myofilament sensitizer and several drugs that enhance Ca++ uptake by the sarcoplasmic reticulum. Cell therapy, using autologous bone marrow and cardiac progenitor cells, appears to be promising, as does gene therapy. Chronic left ventricular assistance with continuous flow pumps is being applied more frequently and successfully as destination therapy, as a bridge to transplantation, and even as a bridge to recovery and explantation. While many of these therapies will improve the care of patients with HF, significant reductions in prevalence will require vigorous, multifaceted, preventive approaches.

  13. Proton Pump Inhibitors and the Risk of Osseointegrated Dental Implant Failure: A Cohort Study.

    PubMed

    Wu, Xixi; Al-Abedalla, Khadijeh; Abi-Nader, Samer; Daniel, Nach G; Nicolau, Belinda; Tamimi, Faleh

    2017-04-01

    Proton pump inhibitors (PPIs) have a negative impact on bone accrual. Because osseointegration is influenced by bone metabolism, this study investigates the association between PPIs and the risk of osseointegrated implant failure. This retrospective cohort study included a total of 1,773 osseointegrated dental implants in 799 patients (133 implants in 58 PPIs users and 1,640 in 741 non-users) who were treated at the East Coast Oral Surgery Clinic in Moncton, Canada, from January 2007 to September 2015. Kaplan-Meier estimator was used to describe the hazard function of dental implant failure by PPIs usage. Multilevel mixed effects parametric survival analyses were used to test the association between PPIs exposure and risk of implant failure adjusting for potential confounders. The failure rates were 6.8% for people using PPIs compared to 3.2% for non-users. Subjects using PPIs had a higher risk of dental implant failure (HR = 2.73; 95% CI = 1.10-6.78) compared to those who did not use the drugs. The findings suggest that treatment with PPIs may be associated with an increased risk of osseointegrated dental implant failure.

  14. Sensor/actuator failure detection for turbofan engines

    NASA Technical Reports Server (NTRS)

    Behbehani, K.; Leininger, G. G.

    1980-01-01

    A procedure for sensor/actuator failure detection using a generalized likelihood ratio (GLR) test is described. The GLR concept can provide a reliable evaluation of failure occurence when associated with a feedback control design which does not require sensor outputs to provide data estimates. A GLR detector was developed and tested.

  15. Spiral silicon drift detectors

    SciTech Connect

    Rehak, P.; Gatti, E.; Longoni, A.; Sampietro, M.; Holl, P.; Lutz, G.; Kemmer, J.; Prechtel, U.; Ziemann, T.

    1988-01-01

    An advanced large area silicon photodiode (and x-ray detector), called Spiral Drift Detector, was designed, produced and tested. The Spiral Detector belongs to the family of silicon drift detectors and is an improvement of the well known Cylindrical Drift Detector. In both detectors, signal electrons created in silicon by fast charged particles or photons are drifting toward a practically point-like collection anode. The capacitance of the anode is therefore kept at the minimum (0.1pF). The concentric rings of the cylindrical detector are replaced by a continuous spiral in the new detector. The spiral geometry detector design leads to a decrease of the detector leakage current. In the spiral detector all electrons generated at the silicon-silicon oxide interface are collected on a guard sink rather than contributing to the detector leakage current. The decrease of the leakage current reduces the parallel noise of the detector. This decrease of the leakage current and the very small capacities of the detector anode with a capacitively matched preamplifier may improve the energy resolution of Spiral Drift Detectors operating at room temperature down to about 50 electrons rms. This resolution is in the range attainable at present only by cooled semiconductor detectors. 5 refs., 10 figs.

  16. Failure Scenarios and Mitigations and for the BaBar Superconducting Solenoid

    SciTech Connect

    Thompson, EunJoo; Candia, A.; Craddock, W.W.; Racine, M.; Weisend, J.G., II; /SLAC

    2005-12-13

    The cryogenic department at the Stanford Linear Accelerator Center is responsible for the operation, troubleshooting, and upgrade of the 1.5 Tesla superconducting solenoid detector for the BABAR B-factory experiment. Events that disable the detector are rare but significantly impact the availability of the detector for physics research. As a result, a number of systems and procedures have been developed over time to minimize the downtime of the detector, for example improved control systems, improved and automatic backup systems, and spares for all major components. Together they can prevent or mitigate many of the failures experienced by the utilities, mechanical systems, controls and instrumentation. In this paper we describe various failure scenarios, their effect on the detector, and the modifications made to mitigate the effects of the failure. As a result of these modifications the reliability of the detector has increased significantly with only 3 shutdowns of the detector due to cryogenics systems over the last 2 years.

  17. Effects of regular and irregular temporal patterns of disturbance on biomass accrual and species composition of a subtidal hard-bottom assemblage

    NASA Astrophysics Data System (ADS)

    Wollgast, Susanne; Lenz, Mark; Wahl, Martin; Molis, Markus

    2008-12-01

    Assessing patterns of species distribution and abundance is important to understand the driving processes of, and predict future changes in, biodiversity. To this date, ecological studies have been mainly designed to investigate the effects of the mean magnitude of predictor variables, although ecological factors naturally vary in space and time. In a nine month long field experiment, we tested the effects of different temporal patterns (regular, lowly and highly irregular) in biomass removal (=disturbance event) on the diversity, species composition, and biomass accrual of macrobenthic assemblages grown on 15 × 15 cm2 PVC-panels. For each pattern of disturbance, disturbance events were timed at three sequences to control for possible confounding effects with recruitment patterns. Disturbance intensity was kept identical among treatments. Assemblages developed in the absence of disturbance for 3 months prior to a 150-day manipulation period, during which the biomass from 20% of the panel area was removed at each of ten disturbance events. Additional undisturbed settlement panels were deployed in the field to assess monthly recruitment rates and species succession over a one year period. Disturbance (i) reduced biomass and total species cover, (ii) changed species composition during the first half of the manipulation period significantly, and (iii) was without effect on species richness and evenness. Irregular disturbance regimes enhanced the abundance of the ascidian Ciona intestinalis, biomass accrual, and total species cover of assemblages relative to the regular disturbance regime, but had either no or only transient effects on diversity and species composition, respectively. Neither the degree of irregularity in disturbance nor the sequence of disturbance events affected any of the response variables significantly. Recruitment of species was strongly seasonal with almost only diatoms recruiting during winter, while recruitment was most intense during summer

  18. Endogenous parathyroid hormone-related protein compensates for the absence of parathyroid hormone in promoting bone accrual in vivo in a model of bone marrow ablation.

    PubMed

    Zhu, Qi; Zhou, Xichao; Zhu, Min; Wang, Qian; Goltzman, David; Karaplis, Andrew; Miao, Dengshun

    2013-09-01

    To assess the effect of hypoparathyroidism on osteogenesis and bone turnover in vivo, bone marrow ablation (BMXs) were performed in tibias of 8-week-old wild-type and parathyroid hormone-null (PTH(-/-)) mice and newly formed bone tissue was analyzed from 5 days to 3 weeks after BMX. At 1 week after BMX, trabecular bone volume, osteoblast numbers, alkaline phosphatase-positive areas, type I collagen-positive areas, PTH receptor-positive areas, calcium sensing receptor-positive areas, and expression of bone formation-related genes were all decreased significantly in the diaphyseal regions of bones of PTH(-/-) mice compared to wild-type mice. In contrast, by 2 weeks after BMX, all parameters related to osteoblastic bone accrual were increased significantly in PTH(-/-) mice. At 5 days after BMX, active tartrate-resistant acid phosphatase (TRAP)-positive osteoclasts had appeared in wild-type mice but were undetectable in PTH(-/-) mice, Both the ratio of mRNA levels of receptor activator of NF-κB ligand (RANKL)/osteoprotegerin (OPG) and TRAP-positive osteoclast surface were still reduced in PTH(-/-) mice at 1 week but were increased by 2 weeks after BMX. The expression levels of parathyroid hormone-related protein (PTHrP) at both mRNA and protein levels were upregulated significantly at 1 week and more dramatically at 2 weeks after BMX in PTH(-/-) mice. To determine whether the increased newly formed bones in PTH(-/-) mice at 2 weeks after BMX resulted from the compensatory action of PTHrP, PTH(-/-) PTHrP(+/-) mice were generated and newly formed bone tissue was compared in these mice with PTH(-/-) and wild-type mice at 2 weeks after BMX. All parameters related to osteoblastic bone formation and osteoclastic bone resorption were reduced significantly in PTH(-/-) PTHrP(+/-) mice compared to PTH(-/-) mice. These results demonstrate that PTH deficiency itself impairs osteogenesis, osteoclastogenesis, and osteoclastic bone resorption, whereas subsequent upregulation of PTHr

  19. Advanced UV Detectors and Detector Arrays

    NASA Technical Reports Server (NTRS)

    Pankove, Jacques I.; Torvik, John

    1998-01-01

    Gallium Nitride (GaN) with its wide energy bandgap of 3.4 eV holds excellent promise for solar blind UV detectors. We have successfully designed, fabricated and tested GaN p-i-n detectors and detector arrays. The detectors have a peak responsivity of 0.14A/W at 363 nm (3.42 eV) at room temperature. This corresponds to an internal quantum efficiency of 56%. The responsivity decreases by several orders of magnitude to 0.008 A/W at 400 nm (3.10 eV) giving the excellent visible rejection ratio needed for solar-blind applications.

  20. Acute kidney failure

    MedlinePlus

    Kidney failure; Renal failure; Renal failure - acute; ARF; Kidney injury - acute ... There are many possible causes of kidney damage. They include: ... cholesterol (cholesterol emboli) Decreased blood flow due to very ...

  1. What Is Heart Failure?

    MedlinePlus

    ... page from the NHLBI on Twitter. What Is Heart Failure? Heart failure is a condition in which the heart can' ... force. Some people have both problems. The term "heart failure" doesn't mean that your heart has stopped ...

  2. GADRAS Detector Response Function.

    SciTech Connect

    Mitchell, Dean J.; Harding, Lee; Thoreson, Gregory G; Horne, Steven M.

    2014-11-01

    The Gamma Detector Response and Analysis Software (GADRAS) applies a Detector Response Function (DRF) to compute the output of gamma-ray and neutron detectors when they are exposed to radiation sources. The DRF is fundamental to the ability to perform forward calculations (i.e., computation of the response of a detector to a known source), as well as the ability to analyze spectra to deduce the types and quantities of radioactive material to which the detectors are exposed. This document describes how gamma-ray spectra are computed and the significance of response function parameters that define characteristics of particular detectors.

  3. "You Need to Be a Good Listener": Recruiters' Use of Relational Communication Behaviors to Enhance Clinical Trial and Research Study Accrual.

    PubMed

    Morgan, Susan E; Occa, Aurora; Potter, JoNell; Mouton, Ashton; Peter, Megan E

    2017-02-01

    Medical and research professionals who discuss clinical trials and research studies with potential participants face an often daunting challenge, particularly when recruiting from minority and underserved populations. This study reports on findings from a focus group study of 63 research coordinators, study nurses, professional recruiters, and other professionals in Indianapolis, IN and Miami, FL who work to recruit from minority and underserved populations. These professionals discussed the importance of creating a sense of connection with potential participants as part of the recruitment and retention process. Building a relationship, however fleeting, involved a number of concrete behaviors, including listening to personal information, expressing empathy, and then providing reciprocal self-disclosures; having repeated contact, usually by working in the same environment over an extended period of time; demonstrating respect through politeness and the use of honorifics; going the extra mile for participants; offering flexibility in scheduling follow-up appointments; and creating a sense of personal and community trust by being truthful. The implications of these findings for clinical trial and research study accrual are discussed.

  4. Heart failure - medicines

    MedlinePlus

    CHF - medicines; Congestive heart failure - medicines; Cardiomyopathy - medicines; HF - medicines ... You will need to take most of your heart failure medicines every day. Some medicines are taken ...

  5. Tin Can Radiation Detector.

    ERIC Educational Resources Information Center

    Crull, John L.

    1986-01-01

    Provides instructions for making tin can radiation detectors from empty aluminum cans, aluminum foil, clear plastic, copper wire, silica gel, and fine, unwaxed dental floss put together with tape or glue. Also provides suggestions for activities using the detectors. (JN)

  6. Thermal kinetic inductance detector

    DOEpatents

    Cecil, Thomas; Gades, Lisa; Miceli, Antonio; Quaranta, Orlando

    2016-12-20

    A microcalorimeter for radiation detection that uses superconducting kinetic inductance resonators as the thermometers. The detector is frequency-multiplexed which enables detector systems with a large number of pixels.

  7. LGB neutron detector

    NASA Astrophysics Data System (ADS)

    Quist, Nicole

    2012-10-01

    The double pulse signature of the Gadolinium Lithium Borate Cerium doped plastic detector suggests its effectiveness for analyzing neutrons while providing gamma ray insensitivity. To better understand this detector, a californium gamma/neutron time of flight facility was constructed in our lab. Reported here are efforts to understand the properties and applications of the LGB detector with regards to neutron spectroscopy.

  8. Advanced Heart Failure

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Advanced Heart Failure Updated:Feb 9,2017 When heart failure (HF) ... content was last reviewed on 04/06/2015. Heart Failure • Home • About Heart Failure • Causes and Risks for ...

  9. Randomized SUSAN edge detector

    NASA Astrophysics Data System (ADS)

    Qu, Zhi-Guo; Wang, Ping; Gao, Ying-Hui; Wang, Peng

    2011-11-01

    A speed up technique for the SUSAN edge detector based on random sampling is proposed. Instead of sliding the mask pixel by pixel on an image as the SUSAN edge detector does, the proposed scheme places the mask randomly on pixels to find edges in the image; we hereby name it randomized SUSAN edge detector (R-SUSAN). Specifically, the R-SUSAN edge detector adopts three approaches in the framework of random sampling to accelerate a SUSAN edge detector: procedure integration of response computation and nonmaxima suppression, reduction of unnecessary processing for obvious nonedge pixels, and early termination. Experimental results demonstrate the effectiveness of the proposed method.

  10. High-energy detector

    DOEpatents

    Bolotnikov, Aleksey E [South Setauket, NY; Camarda, Giuseppe [Farmingville, NY; Cui, Yonggang [Upton, NY; James, Ralph B [Ridge, NY

    2011-11-22

    The preferred embodiments are directed to a high-energy detector that is electrically shielded using an anode, a cathode, and a conducting shield to substantially reduce or eliminate electrically unshielded area. The anode and the cathode are disposed at opposite ends of the detector and the conducting shield substantially surrounds at least a portion of the longitudinal surface of the detector. The conducting shield extends longitudinally to the anode end of the detector and substantially surrounds at least a portion of the detector. Signals read from one or more of the anode, cathode, and conducting shield can be used to determine the number of electrons that are liberated as a result of high-energy particles impinge on the detector. A correction technique can be implemented to correct for liberated electron that become trapped to improve the energy resolution of the high-energy detectors disclosed herein.

  11. The positive effects of growth hormone-releasing peptide-6 on weight gain and fat mass accrual depend on the insulin/glucose status.

    PubMed

    Granado, Miriam; García-Cáceres, Cristina; Frago, Laura M; Argente, Jesús; Chowen, Julie A

    2010-05-01

    Ghrelin and GH secretagogues, including GH-releasing peptide (GHRP)-6, stimulate food intake and adiposity. Because insulin modulates the hypothalamic response to GH secretagogues and acts synergistically with ghrelin on lipogenesis in vitro, we analyzed whether insulin plays a role in the metabolic effects of GHRP-6 in vivo. Streptozotocin-induced diabetic rats received saline, GHRP-6, insulin, or insulin plus GHRP-6 once daily for 8 wk. Rats receiving saline suffered hyperglycemia, hyperphagia, polydipsia, and weight loss. Insulin, but not GHRP-6, improved these parameters (P < 0.001 for all), as well as the diabetes-induced increase in hypothalamic mRNA levels of neuropeptide Y and agouti-related peptide and decrease in proopiomelanocortin. Cocaine amphetamine-related transcript mRNA levels were also reduced in diabetic rats, with GHRP-6 inducing a further decrease (P < 0.03) and insulin an increase. Diabetic rats receiving insulin plus GHRP-6 gained more weight and had increased epididymal fat mass and serum leptin levels compared with all other groups (P < 0.001). In epididymal adipose tissue, diabetic rats injected with saline had smaller adipocytes (P < 0.001), decreased fatty acid synthase (FAS; P < 0.001), and glucose transporter-4 (P < 0.001) and increased hormone sensitive lipase (P < 0.001) and proliferator-activated receptor-gamma mRNA levels (P < 0.01). Insulin normalized these parameters to control values. GHRP-6 treatment increased FAS and glucose transporter-4 gene expression and potentiated insulin's effect on epididymal fat mass, adipocyte size (P < 0.001), FAS (P < 0.001), and glucose transporter-4 (P < 0.05). In conclusion, GHRP-6 and insulin exert an additive effect on weight gain and visceral fat mass accrual in diabetic rats, indicating that some of GHRP-6's metabolic effects depend on the insulin/glucose status.

  12. Phase 2 of Comparative NIR Detector Characterization for NGST

    NASA Technical Reports Server (NTRS)

    Figer, Donald

    2005-01-01

    In accordance with NASA Grant and Cooperative Agreement Handbook, 1260.75 (c) (3), enclosed please find a citation of publications resulting from research for the above referenced grant entitled, "Phase II of Comparative NIR Detector Characterization for NGST." This list can also be accessed at http://idtl.stsci.edu/publications.htm. This project was completed with the failure of two Rockwell NIR detectors. The originally proposed measurements could not be completed.

  13. Neutrino Detectors: Challenges and Opportunities

    SciTech Connect

    Soler, F. J. P.

    2011-10-06

    This paper covers possible detector options suitable at future neutrino facilities, such as Neutrino Factories, Super Beams and Beta Beams. The Magnetised Iron Neutrino Detector (MIND), which is the baseline detector at a Neutrino Factory, will be described and a new analysis which improves the efficiency of this detector at low energies will be shown. Other detectors covered include the Totally Active Scintillating Detectors (TASD), particularly relevant for a low energy Neutrino Factory, emulsion detectors for tau detection, liquid argon detectors and megaton scale water Cherenkov detectors. Finally the requirements of near detectors for long-baseline neutrino experiments will be demonstrated.

  14. Recognition Failure: Another Case of Retrieval Failure

    ERIC Educational Resources Information Center

    Rabinowitz, Jan; And Others

    1977-01-01

    A theoretical explanation of the phenomenon of recognition failure and a presentation of seven experiments investigating performance. Recognition failure is reduced when a more stringent recognition criterion is used, essentially eliminated when the proper access test is used and significantly reduced when variability in recognition performance is…

  15. Study on failure analysis of array chip components in IRFPA

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaonan; He, Yingjie; Li, Jinping

    2016-10-01

    Infrared focal plane array detector has advantages of strong anti-interference ability and high sensitivity. Its size, weight and power dissipation has been noticeably decreased compared to the conventional infrared imaging system. With the development of the detector manufacture technology and the cost reduction, IRFPA detector has been widely used in the military and commercial fields. Due to the restricting of array chip manufacturing process and material defects, the fault phenomenon such as cracking, bad pixel and abnormal output was showed during the test, which restricts the performance of the infrared detector imaging system, and these effects are gradually intensified with the expanding of the focal plane array size and the shrinking of the pixel size. Based on the analysis of the test results for the infrared detector array chip components, the fault phenomenon was classified. The main cause of the chip component failure is chip cracking, bad pixel and abnormal output. The reason of the failure has been analyzed deeply. According to analyze the mechanism of the failure, a series of measures which contain filtrating materials and optimizing the manufacturing process of array chip components were used to improve the performance of the chip components and the test pass rate, which is used to meet the needs of the detector performance.

  16. BATSE spectroscopy detector calibration

    NASA Technical Reports Server (NTRS)

    Band, D.; Ford, L.; Matteson, J.; Lestrade, J. P.; Teegarden, B.; Schaefer, B.; Cline, T.; Briggs, M.; Paciesas, W.; Pendleton, G.

    1992-01-01

    We describe the channel-to-energy calibration of the Spectroscopy Detectors of the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (GRO). These detectors consist of NaI(TI) crystals viewed by photomultiplier tubes whose output in turn is measured by a pulse height analyzer. The calibration of these detectors has been complicated by frequent gain changes and by nonlinearities specific to the BATSE detectors. Nonlinearities in the light output from the NaI crystal and in the pulse height analyzer are shifted relative to each other by changes in the gain of the photomultiplier tube. We present the analytical model which is the basis of our calibration methodology, and outline how the empirical coefficients in this approach were determined. We also describe the complications peculiar to the Spectroscopy Detectors, and how our understanding of the detectors' operation led us to a solution to these problems.

  17. Intelligent Detector Design

    SciTech Connect

    Graf, N.A.; /SLAC

    2012-06-11

    As the complexity and resolution of imaging detectors increases, the need for detailed simulation of the experimental setup also becomes more important. Designing the detectors requires efficient tools to simulate the detector response and reconstruct the events. We have developed efficient and flexible tools for detailed physics and detector response simulation as well as event reconstruction and analysis. The primary goal has been to develop a software toolkit and computing infrastructure to allow physicists from universities and labs to quickly and easily conduct physics analyses and contribute to detector research and development. The application harnesses the full power of the Geant4 toolkit without requiring the end user to have any experience with either Geant4 or C++, thereby allowing the user to concentrate on the physics of the detector system.

  18. Germanium detector vacuum encapsulation

    NASA Technical Reports Server (NTRS)

    Madden, N. W.; Malone, D. F.; Pehl, R. H.; Cork, C. P.; Luke, P. N.; Landis, D. A.; Pollard, M. J.

    1991-01-01

    This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

  19. Detectors (5/5)

    ScienceCinema

    None

    2016-07-12

    This lecture will serve as an introduction to particle detectors and detection techniques. In the first lecture, a historic overview of particle detector development will be given. In the second lecture, some basic techniques and concepts for particle detection will be discussed. In the third lecture, the interaction of particles with matter, the basis of particle detection, will be presented. The fourth and fifth lectures will discuss different detector types used for particle tracking, energy measurement and particle identification.

  20. Detectors (4/5)

    ScienceCinema

    None

    2016-07-12

    This lecture will serve as an introduction to particle detectors and detection techniques. In the first lecture, a historic overview of particle detector development will be given. In the second lecture, some basic techniques and concepts for particle detection will be discussed. In the third lecture, the interaction of particles with matter, the basis of particle detection, will be presented. The fourth and fifth lectures will discuss different detector types used for particle tracking, energy measurement and particle identification.

  1. Photocapacitive MIS infrared detectors

    NASA Technical Reports Server (NTRS)

    Sher, A.; Lu, S. S.-M.; Moriarty, J. A.; Crouch, R. K.; Miller, W. E.

    1978-01-01

    A new class of room-temperature infrared detectors has been developed through use of metal-insulator-semiconductor (MIS) or metal-insulator-semiconductor-insulator-metal (MISIM) slabs. The detectors, which have been fabricated from Si, Ge and GaAs, rely for operation on the electrical capacitance variations induced by modulated incident radiation. The peak detectivity for a 1000-A Si MISIM detector is comparable to that of a conventional Si detector functioning in the photovoltaic mode. Optimization of the photocapacitive-mode detection sensitivity is discussed.

  2. The CDFII Silicon Detector

    SciTech Connect

    Julia Thom

    2004-07-23

    The CDFII silicon detector consists of 8 layers of double-sided silicon micro-strip sensors totaling 722,432 readout channels, making it one of the largest silicon detectors in present use by an HEP experiment. After two years of data taking, we report on our experience operating the complex device. The performance of the CDFII silicon detector is presented and its impact on physics analyses is discussed. We have already observed measurable effects from radiation damage. These results and their impact on the expected lifetime of the detector are briefly reviewed.

  3. Adaptors for radiation detectors

    DOEpatents

    Livesay, Ronald Jason

    2015-07-28

    Described herein are adaptors and other devices for radiation detectors that can be used to make accurate spectral measurements of both small and large bulk sources of radioactivity, such as building structures, soils, vessels, large equipment, and liquid bodies. Some exemplary devices comprise an adaptor for a radiation detector, wherein the adaptor can be configured to collimate radiation passing through the adapter from an external radiation source to the radiation detector and the adaptor can be configured to enclose a radiation source within the adapter to allow the radiation detector to measure radiation emitted from the enclosed radiation source.

  4. Adaptors for radiation detectors

    DOEpatents

    Livesay, Ronald Jason

    2014-04-22

    Described herein are adaptors and other devices for radiation detectors that can be used to make accurate spectral measurements of both small and large bulk sources of radioactivity, such as building structures, soils, vessels, large equipment, and liquid bodies. Some exemplary devices comprise an adaptor for a radiation detector, wherein the adaptor can be configured to collimate radiation passing through the adapter from an external radiation source to the radiation detector and the adaptor can be configured to enclose a radiation source within the adapter to allow the radiation detector to measure radiation emitted from the enclosed radiation source.

  5. Failure in glass

    NASA Technical Reports Server (NTRS)

    Keeton, S. C.

    1972-01-01

    Review of state of the art concerning glass failure mechanisms and fatigue theories discusses brittle fracture in glass, fatigue mechanisms, fatigue behavior, environmental effects on failure rate, and aging.

  6. [Understanding heart failure].

    PubMed

    Boo, José Fernando Guadalajara

    2006-01-01

    Heart failure is a disease with several definitions. The term "heart failure" is used by has brougth about confusion in the terminology. For this reason, the value of the ejection fraction (< 0.40 or < 0.35) is used in most meganalyses on the treatment of heart failure, avoiding the term "heart failure" that is a confounding concept. In this paper we carefully analyze the meaning of contractility, ventricular function or performance, preload, afterload, heart failure, compensation mechanisms in heart failure, myocardial oxygen consumption, inadequate, adequate and inappropriate hypertrophy, systole, diastole, compliance, problems of relaxation, and diastolic dysfunction. Their definitions are supported by the original scientific descriptions in an attempt to clarify the concepts about ventricular function and heart failure and, in this way, use the same scientific language about the meaning of ventricular function, heart failure, and diastolic dysfunction.

  7. Failures in psychodynamic psychotherapy.

    PubMed

    Gold, Jerry; Stricker, George

    2011-11-01

    This article addresses the issue of failures in psychodynamic psychotherapy. Drawing on the clinical and research literatures, and utilizing our clinical experiences, we first describe and define criteria for success and failure in treatment. We then review five factors that can lead to failure: client factors, therapist factors, technical factors, relationship factors, and environmental factors. We illustrate our presentation with a case example, and conclude by discussing ways in which the likelihood of failures in psychodynamic treatment can be lowered.

  8. Ammonia tank failure

    SciTech Connect

    Sweat, M.E.

    1983-04-01

    An ammonia tank failure at Hawkeye Chemical of Clinton, Iowa is discussed. The tank was a double-wall, 27,000 metric-ton tank built in 1968 and commissioned in December 1969. The paper presented covers the cause of the failure, repair, and procedural changes made to prevent recurrence of the failure. (JMT)

  9. SCINTILLATION EXPOSURE RATE DETECTOR

    DOEpatents

    Spears, W.G.

    1960-11-01

    A radiation detector for gamma and x rays is described. The detector comprises a scintillation crystal disposed between a tantalum shield and the input of a photomultiplier tube, the crystal and the shield cooperating so that their combined response to a given quantity of radiation at various energy levels is substantially constant.

  10. Arsenic activation neutron detector

    DOEpatents

    Jacobs, Eddy L.

    1981-01-01

    A detector of bursts of neutrons from a deuterium-deuteron reaction includes a quantity of arsenic adjacent a gamma detector such as a scintillator and photomultiplier tube. The arsenic is activated by the 2.5 Mev neutrons to release gamma radiation which is detected to give a quantitative representation of detected neutrons.

  11. Arsenic activation neutron detector

    DOEpatents

    Jacobs, E.L.

    1980-01-28

    A detector of bursts of neutrons from a deuterium-deuteron reaction includes a quantity of arsenic adjacent a gamma detector such as a scintillator and photomultiplier tube. The arsenic is activated by the 2.5-MeV neutrons to release gamma radiation which is detected to give a quantitative representation of detected neutrons.

  12. Particle impact location detector

    NASA Technical Reports Server (NTRS)

    Auer, S. O.

    1974-01-01

    Detector includes delay lines connected to each detector surface strip. When several particles strike different strips simultaneously, pulses generated by each strip are time delayed by certain intervals. Delay time for each strip is known. By observing time delay in pulse, it is possible to locate strip that is struck by particle.

  13. Borner Ball Neutron Detector

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Bonner Ball Neutron Detector measures neutron radiation. Neutrons are uncharged atomic particles that have the ability to penetrate living tissues, harming human beings in space. The Bonner Ball Neutron Detector is one of three radiation experiments during Expedition Two. The others are the Phantom Torso and Dosimetric Mapping.

  14. Alkali ionization detector

    DOEpatents

    Hrizo, John; Bauerle, James E.; Witkowski, Robert E.

    1982-01-01

    A calibration filament containing a sodium-bearing compound is included in combination with the sensing filament and ion collector plate of a sodium ionization detector to permit periodic generation of sodium atoms for the in-situ calibration of the detector.

  15. Cable-splice detector

    NASA Technical Reports Server (NTRS)

    Lee, R. D.; Iufer, E. J.; Giovannetti, A.

    1980-01-01

    Detector has possible uses in aerial cable-car systems, equipment handling in mines, boreholes, and undersea operations, and other applications where moving steel cable must be measured, monitored, or controlled. Detector consists of Hall-effect magnetic sensor located close to cable. Magnetic markings on cable are converted to electrical signals. Signals are filtered, amplified, and can actuate alarm.

  16. Optical proximity detector

    NASA Technical Reports Server (NTRS)

    Hermann, W. A.; Johnston, A. R.

    1977-01-01

    Sensitive, relatively inexpensive instrument uses phase-detection techniques to sense presence of objects. Phase-sensitive detectors, LED, photodiode with response matched to LED output, and filtering lens allow detector to operate over narrow radiation band, giving selectivity over stray light.

  17. Heart Failure: A Primer.

    PubMed

    Lee, Christopher S; Auld, Jonathan

    2015-12-01

    Heart failure is a complex and multisystem clinical syndrome that results from impaired ventricular contractility and/or relaxation. Hypertension, diabetes mellitus, and coronary artery disease are common antecedents to heart failure. The main pathogenic mechanisms involved in heart failure include sympathetic nervous and renin-angiotensin-aldosterone system activation, as well as inflammation. A detailed history and physical examination and additional diagnostic tests may be needed to diagnose heart failure. Most treatment strategies target neurohormonal systems. Nonpharmacologic interventions and effective engagement in self-care are also important in overall heart failure management. Therapeutic strategies are geared toward prolonging life and optimizing quality of life.

  18. The failure of earthquake failure models

    USGS Publications Warehouse

    Gomberg, J.

    2001-01-01

    In this study I show that simple heuristic models and numerical calculations suggest that an entire class of commonly invoked models of earthquake failure processes cannot explain triggering of seismicity by transient or "dynamic" stress changes, such as stress changes associated with passing seismic waves. The models of this class have the common feature that the physical property characterizing failure increases at an accelerating rate when a fault is loaded (stressed) at a constant rate. Examples include models that invoke rate state friction or subcritical crack growth, in which the properties characterizing failure are slip or crack length, respectively. Failure occurs when the rate at which these grow accelerates to values exceeding some critical threshold. These accelerating failure models do not predict the finite durations of dynamically triggered earthquake sequences (e.g., at aftershock or remote distances). Some of the failure models belonging to this class have been used to explain static stress triggering of aftershocks. This may imply that the physical processes underlying dynamic triggering differs or that currently applied models of static triggering require modification. If the former is the case, we might appeal to physical mechanisms relying on oscillatory deformations such as compaction of saturated fault gouge leading to pore pressure increase, or cyclic fatigue. However, if dynamic and static triggering mechanisms differ, one still needs to ask why static triggering models that neglect these dynamic mechanisms appear to explain many observations. If the static and dynamic triggering mechanisms are the same, perhaps assumptions about accelerating failure and/or that triggering advances the failure times of a population of inevitable earthquakes are incorrect.

  19. The PERDaix detector

    NASA Astrophysics Data System (ADS)

    Bachlechner, Andreas; Beischer, Bastian; Greim, Roman; Kirn, Thomas; Mai, Carsten; Yearwood, Gregorio Roper; Schael, Stefan; Schug, David; Tholen, Heiner; Wienkenhöver, Jens

    2012-12-01

    The PERDaix (Proton Electron Radiation Detector Aix-la-Chapelle) detector is designed to measure charged particles in cosmic rays. It can distinguish particle species up to 5 GV rigidity. PERDaix was flown on the BEXUS-11 balloon on 23rd November 2010. The detector has the dimensions of 246×400×859 mm3, a geometrical acceptance of 32 cm2sr, a low weight of 40 kg and a low power consumption of 60 W. The spectrometer consists of a time-of-flight system, a scintillating fiber tracking detector, a permanent magnet and a transition radiation detector. Silicon photomultipliers are used as photodetectors in the time-of-flight and the tracker system.

  20. Optimal optoacoustic detector design

    NASA Technical Reports Server (NTRS)

    Rosengren, L.-G.

    1975-01-01

    Optoacoustic detectors are used to measure pressure changes occurring in enclosed gases, liquids, or solids being excited by intensity or frequency modulated electromagnetic radiation. Radiation absorption spectra, collisional relaxation rates, substance compositions, and reactions can be determined from the time behavior of these pressure changes. Very successful measurements of gaseous air pollutants have, for instance, been performed by using detectors of this type together with different lasers. The measuring instrument consisting of radiation source, modulator, optoacoustic detector, etc. is often called spectrophone. In the present paper, a thorough optoacoustic detector optimization analysis based upon a review of its theory of operation is introduced. New quantitative rules and suggestions explaining how to design detectors with maximal pressure responsivity and over-all sensitivity and minimal background signal are presented.

  1. Advanced far infrared detectors

    SciTech Connect

    Haller, E.E.

    1993-05-01

    Recent advances in photoconductive and bolometric semiconductor detectors for wavelength 1 mm > {lambda} > 50 {mu}m are reviewed. Progress in detector performance in this photon energy range has been stimulated by new and stringent requirements for ground based, high altitude and space-borne telescopes for astronomical and astrophysical observations. The paper consists of chapters dealing with the various types of detectors: Be and Ga doped Ge photoconductors, stressed Ge:Ga devices and neutron transmutation doped Ge thermistors. Advances in the understanding of basic detector physics and the introduction of modern semiconductor device technology have led to predictable and reliable fabrication techniques. Integration of detectors into functional arrays has become feasible and is vigorously pursued by groups worldwide.

  2. Nanomechanical resonance detector

    DOEpatents

    Grossman, Jeffrey C; Zettl, Alexander K

    2013-10-29

    An embodiment of a nanomechanical frequency detector includes a support structure and a plurality of elongated nanostructures coupled to the support structure. Each of the elongated nanostructures has a particular resonant frequency. The plurality of elongated nanostructures has a range of resonant frequencies. An embodiment of a method of identifying an object includes introducing the object to the nanomechanical resonance detector. A resonant response by at least one of the elongated nanostructures of the nanomechanical resonance detector indicates a vibrational mode of the object. An embodiment of a method of identifying a molecular species of the present invention includes introducing the molecular species to the nanomechanical resonance detector. A resonant response by at least one of the elongated nanostructures of the nanomechanical resonance detector indicates a vibrational mode of the molecular species.

  3. Kidney Failure: What to Expect

    MedlinePlus

    ... Kidneys & How They Work Kidney Disease A-Z Kidney Failure What is kidney failure and how is it treated? Kidney failure ... Methods for Kidney Failure: Peritoneal Dialysis . Peritoneal dialysis Kidney Transplant A kidney transplant places a healthy kidney ...

  4. Detectors for Tomorrow's Instruments

    NASA Technical Reports Server (NTRS)

    Moseley, Harvey

    2009-01-01

    Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

  5. The Belle II Detector

    NASA Astrophysics Data System (ADS)

    Piilonen, Leo; Belle Collaboration, II

    2017-01-01

    The Belle II detector is now under construction at the KEK laboratory in Japan. This project represents a substantial upgrade of the Belle detector (and the KEKB accelerator). The Belle II experiment will record 50 ab-1 of data, a factor of 50 more than that recorded by Belle. This large data set, combined with the low backgrounds and high trigger efficiencies characteristic of an e+e- experiment, should provide unprecedented sensitivity to new physics signatures in B and D meson decays, and in τ lepton decays. The detector comprises many forefront subsystems. The vertex detector consists of two inner layers of silicon DEPFET pixels and four outer layers of double-sided silicon strips. These layers surround a beryllium beam pipe having a radius of only 10 mm. Outside of the vertex detector is a large-radius, small-cell drift chamber, an ``imaging time-of-propagation'' detector based on Cerenkov radiation for particle identification, and scintillating fibers and resistive plate chambers used to identify muons. The detector will begin commissioning in 2017.

  6. Advanced Gravitational Wave Detectors

    NASA Astrophysics Data System (ADS)

    Blair, D. G.; Howell, E. J.; Ju, L.; Zhao, C.

    2012-02-01

    Part I. An Introduction to Gravitational Wave Astronomy and Detectors: 1. Gravitational waves D. G. Blair, L. Ju, C. Zhao and E. J. Howell; 2. Sources of gravitational waves D. G. Blair and E. J. Howell; 3. Gravitational wave detectors D. G. Blair, L. Ju, C. Zhao, H. Miao, E. J. Howell, and P. Barriga; 4. Gravitational wave data analysis B. S. Sathyaprakash and B. F. Schutz; 5. Network analysis L. Wen and B. F. Schutz; Part II. Current Laser Interferometer Detectors: Three Case Studies: 6. The Laser Interferometer Gravitational-Wave Observatory P. Fritschel; 7. The VIRGO detector S. Braccini; 8. GEO 600 H. Lück and H. Grote; Part III. Technology for Advanced Gravitational Wave Detectors: 9. Lasers for high optical power interferometers B. Willke and M. Frede; 10. Thermal noise, suspensions and test masses L. Ju, G. Harry and B. Lee; 11. Vibration isolation: Part 1. Seismic isolation for advanced LIGO B. Lantz; Part 2. Passive isolation J-C. Dumas; 12. Interferometer sensing and control P. Barriga; 13. Stabilizing interferometers against high optical power effects C. Zhao, L. Ju, S. Gras and D. G. Blair; Part IV. Technology for Third Generation Gravitational Wave Detectors: 14. Cryogenic interferometers J. Degallaix; 15. Quantum theory of laser-interferometer GW detectors H. Miao and Y. Chen; 16. ET. A third generation observatory M. Punturo and H. Lück; Index.

  7. Semiconductor neutron detectors

    NASA Astrophysics Data System (ADS)

    Gueorguiev, Andrey; Hong, Huicong; Tower, Joshua; Kim, Hadong; Cirignano, Leonard; Burger, Arnold; Shah, Kanai

    2016-09-01

    Lithium Indium Selenide (LiInSe2) has been under development in RMD Inc. and Fisk University for room temperature thermal neutron detection due to a number of promising properties. The recent advances of the crystal growth, material processing, and detector fabrication technologies allowed us to fabricate large detectors with 100 mm2 active area. The thermal neutron detection sensitivity and gamma rejection ratio (GRR) were comparable to 3He tube with 10 atm gas pressure at comparable dimensions. The synthesis, crystal growth, detector fabrication, and characterization are reported in this paper.

  8. Layered semiconductor neutron detectors

    DOEpatents

    Mao, Samuel S; Perry, Dale L

    2013-12-10

    Room temperature operating solid state hand held neutron detectors integrate one or more relatively thin layers of a high neutron interaction cross-section element or materials with semiconductor detectors. The high neutron interaction cross-section element (e.g., Gd, B or Li) or materials comprising at least one high neutron interaction cross-section element can be in the form of unstructured layers or micro- or nano-structured arrays. Such architecture provides high efficiency neutron detector devices by capturing substantially more carriers produced from high energy .alpha.-particles or .gamma.-photons generated by neutron interaction.

  9. A Proposal to Upgrade the Silicon Strip Detector

    SciTech Connect

    Matis, Howard; Michael, LeVine; Jonathan, Bouchet; Stephane, Bouvier; Artemios, Geromitsos; Gerard, Guilloux; Sonia, Kabana; Christophe, Renard; Howard, Matis; Jim, Thomas; Vi Nham, Tram

    2007-11-05

    The STAR Silicon Strip Detector (SSD) was built by a collaboration of Nantes, Strasbourg and Warsaw collaborators. It is a beautiful detector; it can provide 500 mu m scale pointing resolution at the vertex when working in combination with the TPC. It was first used in Run 4, when half the SSD was installed in an engineering run. The full detector was installed for Run 5 (the Cu-Cu run) and the operation and performance of the detector was very successful. However, in preparation for Run 6, two noisy ladders (out of 20) were replaced and this required that the SSD be removed from the STAR detector. The re-installation of the SSD was not fully successful and so for the next two Runs, 6 and 7, the SSD suffered a cooling system failure that allowed a large fraction of the ladders to overheat and become noisy, or fail. (The cause of the SSD cooling failure was rather trivial but the SSD could not be removed betweens Runs 6 and 7 due to the inability of the STAR detector to roll along its tracks at that time.)

  10. Early complications. Respiratory failure.

    PubMed

    Zwischenberger, J B; Alpard, S K; Bidani, A

    1999-08-01

    Pulmonary complications following thoracic surgery are common and associated with significant morbidity and mortality. Respiratory failure after pneumonectomy occurs in approximately 5% to 15% of cases and significantly increases patient mortality. Strategies for ventilator support are based on the nature of the underlying complication and the pathophysiology of respiratory failure. This article describes the cause and pathophysiology of respiratory failure and pulmonary embolus postpneumonectomy. Diagnosis, management, and innovative therapies are also reviewed.

  11. Virtually-synchronous communication based on a weak failure suspector

    NASA Technical Reports Server (NTRS)

    Schiper, Andre; Ricciardi, Aleta

    1993-01-01

    Failure detectors (or, more accurately Failure Suspectors (FS)) appear to be a fundamental service upon which to build fault-tolerant, distributed applications. This paper shows that a FS with very weak semantics (i.e., that delivers failure and recovery information in no specific order) suffices to implement virtually-synchronous communication (VSC) in an asynchronous system subject to process crash failures and network partitions. The VSC paradigm is particularly useful in asynchronous systems and greatly simplifies building fault-tolerant applications that mask failures by replicating processes. We suggest a three-component architecture to implement virtually-synchronous communication: (1) at the lowest level, the FS component; (2) on top of it, a component (2a) that defines new views; and (3) a component (2b) that reliably multicasts messages within a view. The issues covered in this paper also lead to a better understanding of the various membership service semantics proposed in recent literature.

  12. Failure to thrive.

    PubMed

    Krugman, Scott D; Dubowitz, Howard

    2003-09-01

    Failure to thrive is a condition commonly seen by primary care physicians. Prompt diagnosis and intervention are important for preventing malnutrition and developmental sequelae. Medical and social factors often contribute to failure to thrive. Either extreme of parental attention (neglect or hypervigilance) can lead to failure to thrive. About 25 percent of normal infants will shift to a lower growth percentile in the first two years of life and then follow that percentile; this should not be diagnosed as failure to thrive. Infants with Down syndrome, intrauterine growth retardation, or premature birth follow different growth patterns than normal infants. Many infants with failure to thrive are not identified unless careful attention is paid to plotting growth parameters at routine checkups. A thorough history is the best guide to establishing the etiology of the failure to thrive and directing further evaluation and management. All children with failure to thrive need additional calories for catch-up growth (typically 150 percent of the caloric requirement for their expected, not actual, weight). Few need laboratory evaluation. Hospitalization is rarely required and is indicated only for severe failure to thrive and for those whose safety is a concern. A multidisciplinary approach is recommended when failure to thrive persists despite intervention or when it is severe.

  13. Ultrafast neutron detector

    DOEpatents

    Wang, C.L.

    1985-06-19

    A neutron detector of very high temporal resolution is described. It may be used to measure distributions of neutrons produced by fusion reactions that persist for times as short as about 50 picoseconds.

  14. Pocked surface neutron detector

    DOEpatents

    McGregor, Douglas; Klann, Raymond

    2003-04-08

    The detection efficiency, or sensitivity, of a neutron detector material such as of Si, SiC, amorphous Si, GaAs, or diamond is substantially increased by forming one or more cavities, or holes, in its surface. A neutron reactive material such as of elemental, or any compound of, .sup.10 B, .sup.6 Li, .sup.6 LiF, U, or Gd is deposited on the surface of the detector material so as to be disposed within the cavities therein. The portions of the neutron reactive material extending into the detector material substantially increase the probability of an energetic neutron reaction product in the form of a charged particle being directed into and detected by the neutron detector material.

  15. Modular optical detector system

    DOEpatents

    Horn, Brent A.; Renzi, Ronald F.

    2006-02-14

    A modular optical detector system. The detector system is designed to detect the presence of molecules or molecular species by inducing fluorescence with exciting radiation and detecting the emitted fluorescence. Because the system is capable of accurately detecting and measuring picomolar concentrations it is ideally suited for use with microchemical analysis systems generally and capillary chromatographic systems in particular. By employing a modular design, the detector system provides both the ability to replace various elements of the detector system without requiring extensive realignment or recalibration of the components as well as minimal user interaction with the system. In addition, the modular concept provides for the use and addition of a wide variety of components, including optical elements (lenses and filters), light sources, and detection means, to fit particular needs.

  16. The CBM RICH detector

    NASA Astrophysics Data System (ADS)

    Adamczewski-Musch, J.; Akishin, P.; Becker, K.-H.; Belogurov, S.; Bendarouach, J.; Boldyreva, N.; Chernogorov, A.; Deveaux, C.; Dobyrn, V.; Dürr, M.; Eschke, J.; Förtsch, J.; Heep, J.; Höohne, C.; Kampert, K.-H.; Kochenda, L.; Kopfer, J.; Kravtsov, P.; Kres, I.; Lebedev, S.; Lebedeva, E.; Leonova, E.; Linev, S.; Mahmoud, T.; Michel, J.; Miftakhov, N.; Niebur, W.; Ovcharenko, E.; Pauly, C.; Pfeifer, D.; Querchfeld, S.; Rautenberg, J.; Reinecke, S.; Riabov, Y.; Roshchin, E.; Samsonov, V.; Tarasenkova, O.; Traxler, M.; Ugur, C.; Vznuzdaev, E.; Vznuzdaev, M.

    2016-05-01

    The CBM RICH detector will use CO2 as radiator gas, focussing glass mirrors with Al+MgF2 reflective and protective coating and Hamamatsu H12700 MAPMTs as photon detectors. The detector will serve for electron to pion separation up to momenta of 8 GeV/c and thus enable in CBM the measurement of electromagnetic radiation from the early and dense fireball in A+A collisions at SIS 100. In this article, the current status of the CBM RICH development will be presented including new measurements of the radiation hardness of the H12700 MAPMT and WLS coatings with p-terphenyl, the new concept for the readout electronics, and optimizations ongoing with respect to the mirror mount structure and overall geometry. Prior to the usage in CBM, part of the already ordered MAPMTs will be used to upgrade the HADES RICH detector for a new measurement campaign at SIS 18 from 2018-2020.

  17. Lightning Current Detector

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Lightning Current Detector (LCD) was developed to monitor the magnitude of lightning strikes. Information it supplies is useful in evaluating lightning protection designs for such systems as telephone cables, radio broadcast towers, power transmission equipment and oil well towers.

  18. Pendulum detector testing device

    DOEpatents

    Gonsalves, J.M.

    1997-09-30

    A detector testing device is described which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: (1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, (2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and (3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements. 5 figs.

  19. Pendulum detector testing device

    DOEpatents

    Gonsalves, John M.

    1997-01-01

    A detector testing device which provides consistent, cost-effective, repeatable results. The testing device is primarily constructed of PVC plastic and other non-metallic materials. Sensitivity of a walk-through detector system can be checked by: 1) providing a standard test object simulating the mass, size and material content of a weapon or other contraband, 2) suspending the test object in successive positions, such as head, waist and ankle levels, simulating where the contraband might be concealed on a person walking through the detector system; and 3) swinging the suspended object through each of the positions, while operating the detector system and observing its response. The test object is retained in a holder in which the orientation of the test device or target can be readily changed, to properly complete the testing requirements.

  20. PHENIX detector overview

    NASA Astrophysics Data System (ADS)

    Adcox, K.; Adler, S. S.; Aizama, M.; Ajitanand, N. N.; Akiba, Y.; Akikawa, H.; Alexander, J.; Al-Jamel, A.; Allen, M.; Alley, G.; Amirikas, R.; Aphecetche, L.; Arai, Y.; Archuleta, J. B.; Archuleta, J. R.; Armendariz, R.; Armijo, V.; Aronson, S. H.; Autrey, D.; Averbeck, R.; Awes, T. C.; Azmoun, B.; Baldisseri, A.; Banning, J.; Barish, K. N.; Barker, A. B.; Barnes, P. D.; Barrette, J.; Barta, F.; Bassalleck, B.; Bathe, S.; Batsouli, S.; Baublis, V. V.; Bazilevsky, A.; Begay, R.; Behrendt, J.; Belikov, S.; Belkin, R.; Bellaiche, F. G.; Belyaev, S. T.; Bennett, M. J.; Berdnikov, Y.; Bhaganatula, S.; Biggs, J. C.; Bland, A. W.; Blume, C.; Bobrek, M.; Boissevain, J. G.; Boose, S.; Borel, H.; Borland, D.; Bosze, E.; Botelho, S.; Bowers, J.; Britton, C.; Britton, L.; Brooks, M. L.; Brown, A. W.; Brown, D. S.; Bruner, N.; Bryan, W. L.; Bucher, D.; Buesching, H.; Bumazhnov, V.; Bunce, G.; Burward-Hoy, J.; Butsyk, S. A.; Cafferty, M. M.; Carey, T. A.; Chai, J. S.; Chand, P.; Chang, J.; Chang, W. C.; Chappell, R. B.; Chavez, L. L.; Chernichenko, S.; Chi, C. Y.; Chiba, J.; Chiu, M.; Chollet, S.; Choudhury, R. K.; Christ, T.; Chujo, T.; Chung, M. S.; Chung, P.; Cianciolo, V.; Clark, D. J.; Cobigo, Y.; Cole, B. A.; Constantin, P.; Conway, R.; Cook, K. C.; Crook, D. W.; Cunitz, H.; Cunningham, R.; Cutshaw, M.; D'Enterria, D. G.; Dabrowski, C. M.; Danby, G.; Daniels, S.; Danmura, A.; David, G.; Debraine, A.; Delagrange, H.; Demoss, J.; Denisov, A.; Deshpande, A.; Desmond, E. J.; Dietzsch, O.; Dinesh, B. V.; Drachenberg, J. L.; Drapier, O.; Drees, A.; Du Rietz, R.; Durum, A.; Dutta, D.; Ebisu, K.; Echave, M. A.; Efremenko, Y. V.; El Chenawi, K.; Emery, M. S.; Engo, D.; Enokizono, A.; Enosawa, K.; En'yo, H.; Ericson, N.; Esumi, S.; Evseev, V. A.; Ewell, L.; Fackler, O.; Fellenstein, J.; Ferdousi, T.; Ferrierra, J.; Fields, D. E.; Fleuret, F.; Fokin, S. L.; Fox, B.; Fraenkel, Z.; Frank, S.; Franz, A.; Frantz, J. E.; Frawley, A. D.; Fried, J.; Freidberg, J. P.; Fujisawa, E.; Funahashi, H.; Fung, S.-Y.; Gadrat, S.; Gannon, J.; Garpman, S.; Gastaldi, F.; Gee, T. F.; Gentry, R.; Ghosh, T. K.; Giannotti, P.; Glenn, A.; Godoi, A. L.; Gonin, M.; Gogiberidze, G.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Greene, S. V.; Griffin, V.; Grosse Perdekamp, M.; Gupta, S. K.; Guryn, W.; Gustafsson, H.-Å.; Hachiya, T.; Haggerty, J. S.; Hahn, S.; Halliwell, J.; Hamagaki, H.; Hance, R. H.; Hansen, A. G.; Hara, H.; Harder, J.; Hart, G. W.; Hartouni, E. P.; Harvey, A.; Hawkins, L.; Hayano, R. S.; Hayashi, H.; Hayashi, N.; He, X.; Heine, N.; Heistermann, F.; Held, S.; Hemmick, T. K.; Heuser, J. M.; Hibino, M.; Hicks, J. S.; Higuchi, R.; Hill, J. C.; Hirano, T.; Ho, D. S.; Hoade, R.; Holzmann, W.; Homma, K.; Hong, B.; Hoover, A.; Honaguchi, T.; Hunter, C. T.; Hurst, D. E.; Hutter, R.; Ichihara, T.; Ikonnikov, V. V.; Imai, K.; Inaba, M.; Ippolitov, M. S.; Davis Isenhower, L.; Donald Isenhower, L.; Ishihara, M.; Issah, M.; Ivanov, V. I.; Jacak, B. V.; Jackson, G.; Jackson, J.; Jaffe, D.; Jagadish, U.; Jang, W. Y.; Jayakumar, R.; Jia, J.; Johnson, B. M.; Johnson, J.; Johnson, S. C.; Jones, J. P.; Jones, K.; Joo, K. S.; Jouan, D.; Kahn, S.; Kajihara, F.; Kametani, S.; Kamihara, N.; Kamyshkov, Y.; Kandasamy, A.; Kang, J. H.; Kann, M. R.; Kapoor, S. S.; Kapustinsky, J.; Karadjev, K. V.; Kashikhin, V.; Kato, S.; Katou, K.; Kehayias, H.-J.; Kelley, M. A.; Kelly, S.; Kennedy, M.; Khachaturov, B.; Khanzadeev, A. V.; Khomutnikov, A.; Kikuchi, J.; Kim, D. J.; Kim, D.-W.; Kim, G.-B.; Kim, H. J.; Kim, S. Y.; Kim, Y. G.; Kinnison, W. W.; Kistenev, E.; Kiyomichi, A.; Klein-Boesing, C.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Kochetkov, V.; Koehler, D.; Kohama, T.; Komkov, B. G.; Kopytine, M. L.; Koseki, K.; Kotchenda, L.; Kotchetkov, D.; Koutcheryaev, Iou. A.; Kozlov, A.; Kozlov, V. S.; Kravtsov, P. A.; Kroon, P. J.; Kuberg, C. H.; Kudin, L. G.; Kurata-Nishimura, M.; Kuriatkov, V. V.; Kurita, K.; Kuroki, Y.; Kweon, M. J.; Kwon, Y.; Kyle, G. S.; Labounty, J. J.; Lacey, R.; Lajoie, J. G.; Lauret, J.; Lebedev, A.; Lebedev, V. A.; Lebedev, V. D.; Lee, D. M.; Lee, S.; Leitch, M. J.; Lenz, M.; Lenz, W.; Li, X. H.; Li, Z.; Libby, B.; Libkind, M.; Liccardi, W.; Lim, D. J.; Lin, S.; Liu, M. X.; Liu, X.; Liu, Y.; Liu, Z.; Lockner, E.; Longbotham, N.; Lopez, J. D.; Machnowski, R.; Maguire, C. F.; Mahon, J.; Makdisi, Y. I.; Manko, V. I.; Mao, Y.; Marino, S.; Mark, S. K.; Markacs, S.; Markushin, D. G.; Martinez, G.; Martinez, X. B.; Marx, M. D.; Masaike, A.; Matathias, F.; Matsumoto, T.; McGaughey, P. L.; McCain, M. C.; Mead, J.; Melnikov, E.; Melnikov, Y.; Meng, W. Z.; Merschmeyer, M.; Messer, F.; Messer, M.; Miake, Y.; Miftakhov, N. M.; Migluolio, S.; Milan, J.; Miller, T. E.; Milov, A.; Minuzzo, K.; Mioduszewski, S.; Mischke, R. E.; Mishra, G. C.; Mitchell, J. T.; Miyamoto, Y.; Mohanty, A. K.; Montoya, B. C.; Moore, A.; Moore, T.; Morrison, D. P.; Moscone, G. G.; Moss, J. M.; Mühlbacher, F.; Muniruzzaman, M.; Murata, J.; Murray, M. M.; Musrock, M.; Nagamiya, S.; Nagasaka, Y.; Nagle, J. L.; Nakada, Y.; Nakamura, T.; Nandi, B. K.; Negrin, J.; Newby, J.; Nikkinen, L.; Nikolaev, S. A.; Nilsson, P.; Nishimura, S.; Nyanin, A. S.; Nystrand, J.; O'Brien, E.; O'Conner, P.; Obenshain, F.; Ogilvie, C. A.; Ohnishi, H.; Ojha, I. D.; Ono, M.; Onuchin, V.; Oskarsson, A.; Österman, L.; Otterlund, I.; Oyama, K.; Paffrath, L.; Palounek, A. P. T.; Pancake, C. E.; Pantuev, V. S.; Papavassiliou, V.; Pate, S. F.; Peitzmann, T.; Petersen, R.; Petridis, A. N.; Pinkenburg, C. H.; Pisani, R. P.; Pitukhin, P.; Plagge, T.; Plasil, F.; Pollack, M.; Pope, K.; Prigl, R.; Purschke, M. L.; Purwar, A. K.; Qualls, J. M.; Rankowitz, S.; Rao, G.; Rao, R.; Rau, M.; Ravinovich, I.; Raynis, R.; Read, K. F.; Reygers, K.; Riabov, G.; Riabov, V. G.; Riabov, Yu. G.; Robinson, S. H.; Roche, G.; Romana, A.; Rosati, M.; Roschin, E. V.; Rose, A. A.; Rosnet, P.; Roth, R.; Ruggiero, R.; Ryu, S. S.; Saito, N.; Sakaguchi, A.; Sakaguchi, T.; Sakai, S.; Sako, H.; Sakuma, T.; Salomone, S.; Samsonov, V. M.; Sandhoff, W. F.; Sanfratello, L.; Sangster, T. C.; Santo, R.; Sato, H. D.; Sato, S.; Savino, R.; Sawada, S.; Schlei, B. R.; Schleuter, R.; Schutz, Y.; Sekimoto, M.; Semenov, V.; Seto, R.; Severgin, Y.; Shajii, A.; Shangin, V.; Shaw, M. R.; Shea, T. K.; Shein, I.; Shelikhov, V.; Shibata, T.-A.; Shigaki, K.; Shiina, T.; Shimada, T.; Shin, Y. H.; Sibiriak, I. G.; Silvermyr, D.; Sim, K. S.; Simon-Gillo, J.; Simpson, M.; Singh, C. P.; Singh, V.; Sippach, W.; Sivertz, M.; Skank, H. D.; Skutnik, S.; Sleege, G. A.; Smith, D. C.; Smith, G. D.; Smith, M.; Soldatov, A.; Solodov, G. P.; Soltz, R. A.; Sondheim, W. E.; Sorensen, S.; Sourikova, I.; Staley, F.; Stankus, P. W.; Starinsky, N.; Steffens, S.; Stein, E. M.; Steinberg, P.; Stenlund, E.; Stepanov, M.; Ster, A.; Stewering, J.; Stokes, W.; Stoll, S. P.; Sugioka, M.; Sugitate, T.; Sullivan, J. P.; Sumi, Y.; Sun, Z.; Suzuki-Nara, M.; Takagui, E. M.; Taketani, A.; Tamai, M.; Tanaka, K. H.; Tanaka, Y.; Taniguchi, E.; Tannenbaum, M. J.; Tarakanov, V. I.; Tarasenkova, O. P.; Tepe, J. D.; Thern, R.; Thomas, J. H.; Thomas, J. L.; Thomas, T. L.; Thomas, W. D.; Thornton, G. W.; Tian, W.; Todd, R.; Tojo, J.; Toldo, F.; Torii, H.; Towell, R. S.; Tradeski, J.; Trofimov, V. A.; Tserruya, I.; Tsuruoka, H.; Tsvetkov, A. A.; Tuli, S. K.; Turner, G.; Tydesjö, H.; Tyurin, N.; Urasawa, S.; Usachev, A.; Ushiroda, T.; van Hecke, H. W.; van Lith, M.; Vasiliev, A. A.; Vasiliev, V.; Vassent, M.; Velissaris, C.; Velkovska, J.; Velkovsky, M.; Verhoeven, W.; Villatte, L.; Vinogradov, A. A.; Vishnevskii, V. I.; Volkov, M. A.; von Achen, W.; Vorobyov, A. A.; Vznuzdaev, E. A.; Vznuzdaev, M.; Walker, J. W.; Wan, Y.; Wang, H. Q.; Wang, S.; Watanabe, Y.; Watkins, L. C.; Weimer, T.; White, S. N.; Whitus, B. R.; Williams, C.; Willis, P. S.; Wintenberg, A. L.; Witzig, C.; Wohn, F. K.; Wolniewicz, K.; Wong-Swanson, B. G.; Wood, L.; Woody, C. L.; Wright, L. W.; Wu, J.; Xie, W.; Xu, N.; Yagi, K.; Yamamoto, R.; Yang, Y.; Yokkaichi, S.; Yokota, Y.; Yoneyama, S.; Young, G. R.; Yushmanov, I. E.; Zajc, W. A.; Zhang, C.; Zhang, L.; Zhang, Z.; Zhou, S.; Phenix Collaboration

    2003-03-01

    The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented.

  1. Gaseous leak detector

    DOEpatents

    Juravic, Jr., Frank E.

    1988-01-01

    In a short path length mass-spectrometer type of helium leak detector wherein the helium trace gas is ionized, accelerated and deflected onto a particle counter, an arrangement is provided for converting the detector to neon leak detection. The magnetic field of the deflection system is lowered so as to bring the non linear fringe area of the magnetic field across the ion path, thereby increasing the amount of deflection of the heavier neon ions.

  2. Improved gaseous leak detector

    DOEpatents

    Juravic, F.E. Jr.

    1983-10-06

    In a short path length mass-spectrometer type of helium leak detector wherein the helium trace gas is ionized, accelerated and deflected onto a particle counter, an arrangement is provided for converting the detector to neon leak detection. The magnetic field of the deflection system is lowered so as to bring the nonlinear fringe area of the magnetic field across the ion path, thereby increasing the amount of deflection of the heavier neon ions.

  3. Fiber optic detector

    NASA Astrophysics Data System (ADS)

    Partin, Judy K.; Ward, Thomas E.; Grey, Alan E.

    1990-04-01

    This invention is comprised of a portable fiber optic detector that senses the presence of specific target chemicals by exchanging the target chemical for a fluorescently-tagged antigen that is bound to an antibody which is in turn attached to an optical fiber. Replacing the fluorescently-tagged antigen reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

  4. Fiber optic detector

    SciTech Connect

    Partin, J.K.; Ward, T.E.; Grey, A.E.

    1990-12-31

    This invention is comprised of a portable fiber optic detector that senses the presence of specific target chemicals by exchanging the target chemical for a fluorescently-tagged antigen that is bound to an antibody which is in turn attached to an optical fiber. Replacing the fluorescently-tagged antigen reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

  5. Alkali metal ionization detector

    DOEpatents

    Bauerle, James E.; Reed, William H.; Berkey, Edgar

    1978-01-01

    Variations in the conventional filament and collector electrodes of an alkali metal ionization detector, including the substitution of helical electrode configurations for either the conventional wire filament or flat plate collector; or, the substitution of a plurality of discrete filament electrodes providing an in situ capability for transferring from an operationally defective filament electrode to a previously unused filament electrode without removing the alkali metal ionization detector from the monitored environment. In particular, the helical collector arrangement which is coaxially disposed about the filament electrode, i.e. the thermal ionizer, provides an improved collection of positive ions developed by the filament electrode. The helical filament design, on the other hand, provides the advantage of an increased surface area for ionization of alkali metal-bearing species in a monitored gas environment as well as providing a relatively strong electric field for collecting the ions at the collector electrode about which the helical filament electrode is coaxially positioned. Alternatively, both the filament and collector electrodes can be helical. Furthermore, the operation of the conventional alkali metal ionization detector as a leak detector can be simplified as to cost and complexity, by operating the detector at a reduced collector potential while maintaining the sensitivity of the alkali metal ionization detector adequate for the relatively low concentration of alkali vapor and aerosol typically encountered in leak detection applications.

  6. The Belle detector

    NASA Astrophysics Data System (ADS)

    Abashian, A.; Gotow, K.; Morgan, N.; Piilonen, L.; Schrenk, S.; Abe, K.; Adachi, I.; Alexander, J. P.; Aoki, K.; Behari, S.; Doi, Y.; Enomoto, R.; Fujii, H.; Fujita, Y.; Funahashi, Y.; Haba, J.; Hamasaki, H.; Haruyama, T.; Hayashi, K.; Higashi, Y.; Hitomi, N.; Igarashi, S.; Igarashi, Y.; Iijima, T.; Ikeda, Hirokazu; Ikeda, Hitomi; Itoh, R.; Iwai, M.; Iwasaki, H.; Iwasaki, Y.; Joo, K. K.; Kasami, K.; Katayama, N.; Kawai, M.; Kichimi, H.; Kobayashi, T.; Koike, S.; Kondo, Y.; Lee, M. H.; Makida, Y.; Manabe, A.; Matsuda, T.; Murakami, T.; Nagayama, S.; Nakao, M.; Nozaki, T.; Ogawa, K.; Ohkubo, R.; Ohnishi, Y.; Ozaki, H.; Sagawa, H.; Saito, M.; Sakai, Y.; Sasaki, T.; Sato, N.; Sumiyoshi, T.; Suzuki, J.; Suzuki, J. I.; Suzuki, S.; Takasaki, F.; Tamai, K.; Tanaka, M.; Tatomi, T.; Tsuboyama, T.; Tsukada, K.; Tsukamoto, T.; Uehara, S.; Ujiie, N.; Uno, S.; Yabsley, B.; Yamada, Y.; Yamaguchi, H.; Yamaoka, H.; Yamaoka, Y.; Yamauchi, M.; Yoshimura, Y.; Zhao, H.; Abe, R.; Iwai, G.; Kawasaki, T.; Miyata, H.; Shimada, K.; Takahashi, S.; Tamura, N.; Abe, K.; Hanada, H.; Nagamine, T.; Nakajima, M.; Nakajima, T.; Narita, S.; Sanpei, M.; Takayama, T.; Ueki, M.; Yamaga, M.; Yamaguchi, A.; Ahn, B. S.; Kang, J. S.; Kim, Hyunwoo; Park, C. W.; Park, H.; Ahn, H. S.; Jang, H. K.; Kim, C. H.; Kim, S. K.; Lee, S. H.; Park, C. S.; Won, E.; Aihara, H.; Higuchi, T.; Kawai, H.; Matsubara, T.; Nakadaira, T.; Tajima, H.; Tanaka, J.; Tomura, T.; Yokoyama, M.; Akatsu, M.; Fujimoto, K.; Hirose, M.; Inami, K.; Ishikawa, A.; Itami, S.; Kani, T.; Matsumoto, T.; Nagai, I.; Okabe, T.; Oshima, T.; Senyo, K.; Sugi, A.; Sugiyama, A.; Suitoh, S.; Suzuki, S.; Tomoto, M.; Yoshida, K.; Akhmetshin, R.; Chang, P.; Chao, Y.; Chen, Y. Q.; Hou, W. S.; Hsu, S. C.; Huang, H. C.; Huang, T. J.; Lee, M. C.; Lu, R. S.; Peng, J. C.; Peng, K. C.; Sahu, S.; Sung, H. F.; Tsai, K. L.; Ueno, K.; Wang, C. C.; Wang, M. Z.; Alimonti, G.; Browder, T. E.; Casey, B. C. K.; Fang, F.; Guler, H.; Jones, M.; Li, Y.; Olsen, S. L.; Peters, M.; Rodriguez, J. L.; Rosen, M.; Swain, S.; Trabelsi, K.; Varner, G.; Yamamoto, H.; Zheng, Y. H.; An, Q.; Chen, H. F.; Wang, Y. F.; Xu, Z. Z.; Ye, S. W.; Zhang, Z. P.; Asai, M.; Asano, Y.; Mori, S.; Stanič, S.; Tsujita, Y.; Zhang, J.; Žontar, D.; Aso, T.; Aulchenko, V.; Beiline, D.; Bondar, A.; Dneprovsky, L.; Eidelman, S.; Garmash, A.; Kuzmin, A.; Romanov, L.; Root, N.; Shwartz, B.; Sidorov, A.; Sidorov, V.; Usov, Y.; Zhilich, V.; Bakich, A. M.; Peak, L. S.; Varvell, K. E.; Banas, E.; Bozek, A.; Jalocha, P.; Kapusta, P.; Natkaniec, Z.; Ostrowicz, W.; Palka, H.; Rozanka, M.; Rybicki, K.; Behera, P. K.; Mohapatra, A.; Satapathy, M.; Chang, Y. H.; Chen, H. S.; Dong, L. Y.; Li, J.; Liu, H. M.; Mao, Z. P.; Yu, C. X.; Zhang, C. C.; Zhang, S. Q.; Zhao, Z. G.; Zheng, Z. P.; Cheon, B. G.; Choi, Y.; Kim, D. W.; Nam, J. W.; Chidzik, S.; Korotuschenko, K.; Leonidopoulos, C.; Liu, T.; Marlow, D.; Mindas, C.; Prebys, E.; Rabberman, R.; Sands, W.; Wixted, R.; Choi, S.; Dragic, J.; Everton, C. W.; Gordon, A.; Hastings, N. C.; Heenan, E. M.; Moffitt, L. C.; Moloney, G. R.; Moorhead, G. F.; Sevior, M. E.; Taylor, G. N.; Tovey, S. N.; Drutskoy, A.; Kagan, R.; Pakhlov, P.; Semenov, S.; Fukunaga, C.; Suda, R.; Fukushima, M.; Goriletsky, V. I.; Grinyov, B. V.; Lyubinsky, V. R.; Panova, A. I.; Shakhova, K. V.; Shpilinskaya, L. I.; Vinograd, E. L.; Zaslavsky, B. G.; Guo, R. S.; Haitani, F.; Hoshi, Y.; Neichi, K.; Hara, K.; Hara, T.; Hazumi, M.; Hojo, T.; Jackson, D.; Miyake, H.; Nagashima, Y.; Ryuko, J.; Sumisawa, K.; Takita, M.; Yamanaka, T.; Hayashii, H.; Miyabayashi, K.; Noguchi, S.; Hikita, S.; Hirano, H.; Hoshina, K.; Mamada, H.; Nitoh, O.; Okazaki, N.; Yokoyama, T.; Ishino, H.; Ichizawa, S.; Hirai, T.; Kakuno, H.; Kaneko, J.; Nakamura, T.; Ohshima, Y.; Watanabe, Y.; Yanaka, S.; Inoue, Y.; Nakano, E.; Takahashi, T.; Teramoto, Y.; Kang, J. H.; Kim, H. J.; Kim, Heejong; Kwon, Y.-J.; Kawai, H.; Kurihara, E.; Ooba, T.; Suzuki, K.; Unno, Y.; Kawamura, N.; Yuta, H.; Kinoshita, K.; Satpathy, A.; Kobayashi, S.; Kuniya, T.; Murakami, A.; Tsukamoto, T.; Kumar, S.; Singh, J.; Lange, J.; Stock, R.; Matsumoto, S.; Watanabe, M.; Matsuo, H.; Nishida, S.; Nomura, T.; Sakamoto, H.; Sasao, N.; Ushiroda, Y.; Nagasaka, Y.; Tanaka, Y.; Ogawa, S.; Shibuya, H.; Hanagaki, K.; Okuno, S.; Shen, D. Z.; Yan, D. S.; Yin, Z. W.; Tan, N.; Wang, C. H.; Yamaki, T.; Yamashita, Y.

    2002-02-01

    The Belle detector was designed and constructed to carry out quantitative studies of rare B-meson decay modes with very small branching fractions using an asymmetric e +e - collider operating at the ϒ(4S) resonance, the KEK-B-factory. Such studies require data samples containing ˜10 7 B-meson decays. The Belle detector is configured around a 1.5 T superconducting solenoid and iron structure surrounding the KEK-B beams at the Tsukuba interaction region. B-meson decay vertices are measured by a silicon vertex detector situated just outside of a cylindrical beryllium beam pipe. Charged particle tracking is performed by a wire drift chamber (CDC). Particle identification is provided by d E/d x measurements in CDC, aerogel threshold Cherenkov counter and time-of-flight counter placed radially outside of CDC. Electromagnetic showers are detected in an array of CsI( Tl) crystals located inside the solenoid coil. Muons and K L mesons are identified by arrays of resistive plate counters interspersed in the iron yoke. The detector covers the θ region extending from 17° to 150°. The part of the uncovered small-angle region is instrumented with a pair of BGO crystal arrays placed on the surfaces of the QCS cryostats in the forward and backward directions. Details of the design and development works of the detector subsystems, which include trigger, data acquisition and computer systems, are described. Results of performance of the detector subsystems are also presented.

  7. Gamma ray detector modules

    NASA Technical Reports Server (NTRS)

    Capote, M. Albert (Inventor); Lenos, Howard A. (Inventor)

    2009-01-01

    A radiation detector assembly has a semiconductor detector array substrate of CdZnTe or CdTe, having a plurality of detector cell pads on a first surface thereof, the pads having a contact metallization and a solder barrier metallization. An interposer card has planar dimensions no larger than planar dimensions of the semiconductor detector array substrate, a plurality of interconnect pads on a first surface thereof, at least one readout semiconductor chip and at least one connector on a second surface thereof, each having planar dimensions no larger than the planar dimensions of the interposer card. Solder columns extend from contacts on the interposer first surface to the plurality of pads on the semiconductor detector array substrate first surface, the solder columns having at least one solder having a melting point or liquidus less than 120 degrees C. An encapsulant is disposed between the interposer circuit card first surface and the semiconductor detector array substrate first surface, encapsulating the solder columns, the encapsulant curing at a temperature no greater than 120 degrees C.

  8. Cadmium mercury telluride infrared detectors

    NASA Astrophysics Data System (ADS)

    Elliott, C. T.

    Signal Processing In The Element (SPITE) detectors used in high performance thermal imaging systems are discussed. Developments to improve spatial and temperature resolution are outlined. Focal plane arrays of electronically scanned two-dimensional arrays of CMT detectors are treated. Use of photovoltaic CMT detectors hybridized with silicon addressing circuits is reported. Research to raise the operating temperature of infrared detectors is summarized.

  9. Progress in semiconductor drift detectors

    SciTech Connect

    Rehak, P.; Walton, J.; Gatti, E.; Longoni, A.; Sanpietro, M.; Kemmer, J.; Dietl, H.; Holl, P.; Klanner, R.; Lutz, G.

    1985-01-01

    Progress in testing semiconductor drift detectors is reported. Generally better position and energy resolutions were obtained than resolutions published previously. The improvement is mostly due to new electronics better matched to different detectors. It is shown that semiconductor drift detectors are becoming versatile and reliable detectors for position and energy measurements.

  10. Physics with the collider detectors at RHIC and the LHC

    SciTech Connect

    Thomas, J.; Hallman, T.

    1995-07-15

    On January 8, 1995, over 180 participants gathered to hear the QM95 preconference workshop on `Physics with the Collider Detectors at RHIC and the LHC`. The goal was to bring together the experimentalists from a wide community of hadron and heavy ion collider detector collaborations. The speakers were encouraged to present the current status of their detectors, with all the blemishes, and the audience was encouraged to share their successes and failures in approaching similar detector design issues. The presentations were excellent and the discussions were lively and stimulating. The editors hope that the reader will find these proceedings to be equally stimulating. Separate abstracts have been submitted to the energy database from articles in this report.

  11. Living with Respiratory Failure

    MedlinePlus

    ... smoking. Emotional Issues and Support Living with respiratory failure may cause fear, anxiety, depression, and stress. Talk about how you feel with your health care team. Talking to a professional counselor also can ... to living with respiratory failure. You can see how other people who have ...

  12. Ampoule Failure System

    NASA Technical Reports Server (NTRS)

    Watring, Dale A. (Inventor); Johnson, Martin L. (Inventor)

    1996-01-01

    An ampoule failure system for use in material processing furnaces comprising a containment cartridge and an ampoule failure sensor. The containment cartridge contains an ampoule of toxic material therein and is positioned within a furnace for processing. An ampoule failure probe is positioned in the containment cartridge adjacent the ampoule for detecting a potential harmful release of toxic material therefrom during processing. The failure probe is spaced a predetermined distance from the ampoule and is chemically chosen so as to undergo a timely chemical reaction with the toxic material upon the harmful release thereof. The ampoule failure system further comprises a data acquisition system which is positioned externally of the furnace and is electrically connected to the ampoule failure probe so as to form a communicating electrical circuit. The data acquisition system includes an automatic shutdown device for shutting down the furnace upon the harmful release of toxic material. It also includes a resistance measuring device for measuring the resistance of the failure probe during processing. The chemical reaction causes a step increase in resistance of the failure probe whereupon the automatic shutdown device will responsively shut down the furnace.

  13. Generalized energy failure criterion.

    PubMed

    Qu, R T; Zhang, Z J; Zhang, P; Liu, Z Q; Zhang, Z F

    2016-03-21

    Discovering a generalized criterion that can predict the mechanical failure of various different structural materials is one of ultimate goals for scientists in both material and mechanics communities. Since the first study on the failure criterion of materials by Galileo, about three centuries have passed. Now we eventually find the "generalized energy criterion", as presented here, which appears to be one universal law for various different kinds of materials. The validity of the energy criterion for quantitatively predicting the failure is experimentally confirmed using a metallic glass. The generalized energy criterion reveals the competition and interaction between shear and cleavage, the two fundamental inherent failure mechanisms, and thus provides new physical insights into the failure prediction of materials and structural components.

  14. Acute Decompensated Heart Failure

    PubMed Central

    Joseph, Susan M.; Cedars, Ari M.; Ewald, Gregory A.; Geltman, Edward M.; Mann, Douglas L.

    2009-01-01

    Hospitalizations for acute decompensated heart failure are increasing in the United States. Moreover, the prevalence of heart failure is increasing consequent to an increased number of older individuals, as well as to improvement in therapies for coronary artery disease and sudden cardiac death that have enabled patients to live longer with cardiovascular disease. The main treatment goals in the hospitalized patient with heart failure are to restore euvolemia and to minimize adverse events. Common in-hospital treatments include intravenous diuretics, vasodilators, and inotropic agents. Novel pharmaceutical agents have shown promise in the treatment of acute decompensated heart failure and may simplify the treatment and reduce the morbidity associated with the disease. This review summarizes the contemporary management of patients with acute decompensated heart failure. PMID:20069075

  15. Generalized energy failure criterion

    PubMed Central

    Qu, R. T.; Zhang, Z. J.; Zhang, P.; Liu, Z. Q.; Zhang, Z. F.

    2016-01-01

    Discovering a generalized criterion that can predict the mechanical failure of various different structural materials is one of ultimate goals for scientists in both material and mechanics communities. Since the first study on the failure criterion of materials by Galileo, about three centuries have passed. Now we eventually find the “generalized energy criterion”, as presented here, which appears to be one universal law for various different kinds of materials. The validity of the energy criterion for quantitatively predicting the failure is experimentally confirmed using a metallic glass. The generalized energy criterion reveals the competition and interaction between shear and cleavage, the two fundamental inherent failure mechanisms, and thus provides new physical insights into the failure prediction of materials and structural components. PMID:26996781

  16. Detectors in Extreme Conditions

    SciTech Connect

    Blaj, G.; Carini, G.; Carron, S.; Haller, G.; Hart, P.; Hasi, J.; Herrmann, S.; Kenney, C.; Segal, J.; Tomada, A.

    2015-08-06

    Free Electron Lasers opened a new window on imaging the motion of atoms and molecules. At SLAC, FEL experiments are performed at LCLS using 120Hz pulses with 1012 - 1013 photons in 10 femtoseconds (billions of times brighter than the most powerful synchrotrons). This extreme detection environment raises unique challenges, from obvious to surprising. Radiation damage is a constant threat due to accidental exposure to insufficiently attenuated beam, focused beam and formation of ice crystals reflecting the beam onto the detector. Often high power optical lasers are also used (e.g., 25TW), increasing the risk of damage or impeding data acquisition through electromagnetic pulses (EMP). The sample can contaminate the detector surface or even produce shrapnel damage. Some experiments require ultra high vacuum (UHV) with strict design, surface contamination and cooling requirements - also for detectors. The setup is often changed between or during experiments with short turnaround times, risking mechanical and ESD damage, requiring work planning, training of operators and sometimes continuous participation of the LCLS Detector Group in the experiments. The detectors used most often at LCLS are CSPAD cameras for hard x-rays and pnCCDs for soft x-rays.

  17. [Heart failure and comorbidities].

    PubMed

    Boully, Clémence; Hanon, Olivier

    2015-03-01

    Heart failure is a frequent disease in the elderly. Its clinical presentation is less typical and the prognosis more severe than in younger subjects because heart failure occurs in patients with multiple comorbidities. A comprehensive geriatric assessment should therefore be performed to detect the vulnerabilities and manage the comorbidities. The main diseases associated with heart failure are dementia, depression, malnutrition, atrial fibrillation, coronary artery disease, orthostatic hypotension, renal failure, anemia and iron deficiency. Comorbidities worsen heart failure and makes its treatment more difficult. The identification and treatment of comorbidities improve the prognosis in terms of mortality but especially in terms of quality of life. Caution with drugs is necessary because of pharmacokinetic or pharmacodynamic changes related to aging and the comorbidities. In this context, clinical and laboratory monitoring should be increased, mostly during an acute event (acute heart failure, infection, dehydration, fall, new therapy…). Therefore, the follow-up of elderly patients with heart failure requires a multidisciplinary approach that involves close cooperation between cardiologists, geriatricians, general practitioners, nurses, and pharmacists.

  18. Semiconductor radiation detector

    DOEpatents

    Patt, Bradley E.; Iwanczyk, Jan S.; Tull, Carolyn R.; Vilkelis, Gintas

    2002-01-01

    A semiconductor radiation detector is provided to detect x-ray and light photons. The entrance electrode is segmented by using variable doping concentrations. Further, the entrance electrode is physically segmented by inserting n+ regions between p+ regions. The p+ regions and the n+ regions are individually biased. The detector elements can be used in an array, and the p+ regions and the n+ regions can be biased by applying potential at a single point. The back side of the semiconductor radiation detector has an n+ anode for collecting created charges and a number of p+ cathodes. Biased n+ inserts can be placed between the p+ cathodes, and an internal resistor divider can be used to bias the n+ inserts as well as the p+ cathodes. A polysilicon spiral guard can be implemented surrounding the active area of the entrance electrode or surrounding an array of entrance electrodes.

  19. Handheld CZT radiation detector

    DOEpatents

    Murray, William S.; Butterfield, Kenneth B.; Baird, William

    2004-08-24

    A handheld CZT radiation detector having a CZT gamma-ray sensor, a multichannel analyzer, a fuzzy-logic component, and a display component is disclosed. The CZT gamma-ray sensor may be a coplanar grid CZT gamma-ray sensor, which provides high-quality gamma-ray analysis at a wide range of operating temperatures. The multichannel analyzer categorizes pulses produce by the CZT gamma-ray sensor into channels (discrete energy levels), resulting in pulse height data. The fuzzy-logic component analyzes the pulse height data and produces a ranked listing of radioisotopes. The fuzzy-logic component is flexible and well-suited to in-field analysis of radioisotopes. The display component may be a personal data assistant, which provides a user-friendly method of interacting with the detector. In addition, the radiation detector may be equipped with a neutron sensor to provide an enhanced mechanism of sensing radioactive materials.

  20. JSATS Detector Field Manual

    SciTech Connect

    Choi, Eric Y.; Flory, Adam E.; Lamarche, Brian L.; Weiland, Mark A.

    2014-06-01

    The Juvenile Salmon Acoustic Telemetry System (JSATS) Detector is a software and hardware system that captures JSATS Acoustic Micro Transmitter (AMT) signals. The system uses hydrophones to capture acoustic signals in the water. This analog signal is then amplified and processed by the Analog to Digital Converter (ADC) and Digital Signal Processor (DSP) board in the computer. This board digitizes and processes the acoustic signal to determine if a possible JSATS tag is present. With this detection, the data will be saved to the computer for further analysis. This document details the features and functionality of the JSATS Detector software. The document covers how to install the software, setup and run the detector software. The document will also go over the raw binary waveform file format and CSV files containing RMS values

  1. Liver Failure in Pregnancy.

    PubMed

    Bacak, Stephen J; Thornburg, Loralei L

    2016-01-01

    Acute liver failure is a rare but life-threatening medical emergency in pregnancy whose true incidence remains unknown. Many cases of acute liver failure are caused by pregnancy-related conditions such as acute fatty liver of pregnancy and HELLP syndrome. However, acute deterioration in liver function can also be caused by drug overdose, viral infections, and an exacerbation of underlying chronic liver disease. This article provides an overview of the normal liver changes that occur during pregnancy, and summarizes the most common conditions and general management strategies of liver failure during pregnancy.

  2. Damage mechanics - failure modes

    SciTech Connect

    Krajcinovic, D.; Vujosevic, M.

    1996-12-31

    The present study summarizes the results of the DOE sponsored research program focused on the brittle failure of solids with disordered microstructure. The failure is related to the stochastic processes on the microstructural scale; namely, the nucleation and growth of microcracks. The intrinsic failure modes, such as the percolation, localization and creep rupture, are studied by emphasizing the effect of the micro-structural disorder. A rich spectrum of physical phenomena and new concepts that emerges from this research demonstrates the reasons behind the limitations of traditional, deterministic, and local continuum models.

  3. Magnet Coil Shorted Turn Detector

    SciTech Connect

    Dinkel, J.A.; Biggs, J.E.

    1994-03-01

    The Magnet Coil Shorted Turn Detector has been developed to facilitate the location of shorted turns in magnet coils. Finding these shorted turns is necessary to determine failure modes that are a necessary step in developing future production techniques. Up to this point, coils with shorted turns had the insulation burned off without the fault having been located. This disassembly process destroyed any chance of being able to find the fault. In order to maintain a flux balance in a coupled system such as a magnet coil, the current in a shorted turn must be opposed to the incident current. If the direction of the current in each conductor can be measured relative to the incident current, then the exact location of the short can be determined. In this device, an AC voltage is applied to the magnet under test. A small hand held B-dot pickup coil monitors the magnetic field produced by current in the individual magnet conductors. The relative phase of this pickup coil voltage is compared to a reference signal derived from the input current to detect a current reversal as the B-dot pickup coil is swept over the conductors of the coil under test. This technique however, is limited to only those conductors that are accessible to the hand held probe.

  4. RADIATION WAVE DETECTOR

    DOEpatents

    Wouters, L.F.

    1958-10-28

    The detection of the shape and amplitude of a radiation wave is discussed, particularly an apparatus for automatically indicating at spaced lntervals of time the radiation intensity at a flxed point as a measure of a radiation wave passing the point. The apparatus utilizes a number of photomultiplier tubes surrounding a scintillation type detector, For obtainlng time spaced signals proportional to radiation at predetermined intervals the photolnultiplier tubes are actuated ln sequence following detector incidence of a predetermined radiation level by electronic means. The time spaced signals so produced are then separately amplified and relayed to recording means.

  5. Glow discharge detector

    DOEpatents

    Koo, Jackson C.; Yu, Conrad M.

    2002-01-01

    A highly sensitive electronic ion cell for the measurement of trace elements in He carrier gas which involves glow discharge. A constant wave (CW) glow discharge detector which is controlled through a biased resistor, can detect the change of electron density caused by impurities in the He carrier gas by many orders of magnitude larger than that caused by direct ionization or electron capture. The glow discharge detector utilizes a floating pseudo-electrode to form a probe in or near the plasma. By using this probe, the large variation of electron density due to trace amounts of impurities can be directly measured.

  6. Ultrasonic liquid level detector

    DOEpatents

    Kotz, Dennis M.; Hinz, William R.

    2010-09-28

    An ultrasonic liquid level detector for use within a shielded container, the detector being tubular in shape with a chamber at its lower end into which liquid from in the container may enter and exit, the chamber having an ultrasonic transmitter and receiver in its top wall and a reflector plate or target as its bottom wall whereby when liquid fills the chamber a complete medium is then present through which an ultrasonic wave may be transmitted and reflected from the target thus signaling that the liquid is at chamber level.

  7. High efficiency photoionization detector

    DOEpatents

    Anderson, D.F.

    1984-01-31

    A high efficiency photoionization detector is described using tetraaminoethylenes in a gaseous state having a low ionization potential and a relative photoionization cross section which closely matches the emission spectrum of xenon gas. Imaging proportional counters are also disclosed using the novel photoionization detector of the invention. The compound of greatest interest is TMAE which comprises tetrakis(dimethylamino)ethylene which has a measured ionization potential of 5.36 [+-] 0.02 eV, and a vapor pressure of 0.35 torr at 20 C. 6 figs.

  8. Acoustic emission intrusion detector

    DOEpatents

    Carver, Donald W.; Whittaker, Jerry W.

    1980-01-01

    An intrusion detector is provided for detecting a forcible entry into a secured structure while minimizing false alarms. The detector uses a piezoelectric crystal transducer to sense acoustic emissions. The transducer output is amplified by a selectable gain amplifier to control the sensitivity. The rectified output of the amplifier is applied to a Schmitt trigger circuit having a preselected threshold level to provide amplitude discrimination. Timing circuitry is provided which is activated by successive pulses from the Schmitt trigger which lie within a selected time frame for frequency discrimination. Detected signals having proper amplitude and frequency trigger an alarm within the first complete cycle time of a detected acoustical disturbance signal.

  9. Radiation Detectors and Art

    NASA Astrophysics Data System (ADS)

    Denker, Andrea

    The use of radiation detectors in the analysis of art objects represents a very special application in a true interdisciplinary field. Radiation detectors employed in this field detect, e.g., x-rays, γ-rays, β particles, and protons. Analyzed materials range from stones, metals, over porcelain to paintings. The available nondestructive and noninvasive analytical methods cover a broad range of techniques. Hence, for the sake of brevity, this chapter will concentrate on few techniques: Proton Induced X-ray Emission (PIXE) and Proton Induced γ-ray Emission (PIGE).

  10. Semiconductor neutron detector

    DOEpatents

    Ianakiev, Kiril D.; Littlewood, Peter B.; Blagoev, Krastan B.; Swinhoe, Martyn T.; Smith, James L.; Sullivan, Clair J.; Alexandrov, Boian S.; Lashley, Jason Charles

    2011-03-08

    A neutron detector has a compound of lithium in a single crystal form as a neutron sensor element. The lithium compound, containing improved charge transport properties, is either lithium niobate or lithium tantalate. The sensor element is in direct contact with a monitor that detects an electric current. A signal proportional to the electric current is produced and is calibrated to indicate the neutrons sensed. The neutron detector is particularly useful for detecting neutrons in a radiation environment. Such radiation environment may, e.g. include gamma radiation and noise.

  11. High efficiency photoionization detector

    DOEpatents

    Anderson, David F.

    1984-01-01

    A high efficiency photoionization detector using tetraaminoethylenes in a gaseous state having a low ionization potential and a relative photoionization cross section which closely matches the emission spectrum of xenon gas. Imaging proportional counters are also disclosed using the novel photoionization detector of the invention. The compound of greatest interest is TMAE which comprises tetrakis(dimethylamino)ethylene which has a measured ionization potential of 5.36.+-.0.02 eV, and a vapor pressure of 0.35 torr at 20.degree. C.

  12. High performance pyroelectric infrared detector

    NASA Astrophysics Data System (ADS)

    Hu, Xu; Luo, Haosu; Ji, Yulong; Yang, Chunli

    2015-10-01

    Single infrared detector made with Relaxative ferroelectric crystal(PMNT) present excellence performance. In this paper include detector capacitance, characteristic of frequency--response, characteristic of detectivity. The measure result show that detectivity of detector made with relaxative ferroelectric crystal(PMNT) exceed three times than made with LT, the D*achieved than 1*109cmHz0.5W-1. The detector will be applied on NDIR spectrograph, FFT spectrograph and so on. The high performance pyroelectric infrared detector be developed that will be broadened application area of infrared detector.

  13. The Upgraded D0 detector

    SciTech Connect

    Abazov, V.M.; Abbott, B.; Abolins, M.; Acharya, B.S.; Adams, D.L.; Adams, M.; Adams, T.; Agelou, M.; Agram, J.-L.; Ahmed, S.N.; Ahn, S.H.; Ahsan, M.; Alexeev, G.D.; Alkhazov, G.; Alton, A.; Alverson, G.; Alves, G.A.; Anastasoaie, M.; Andeen, T.; Anderson, J.T.; Anderson, S.; /Buenos Aires U. /Rio de Janeiro, CBPF /Sao Paulo, IFT /Alberta U. /Simon Fraser U. /York U., Canada /McGill U. /Beijing, Inst. High Energy Phys. /Hefei, CUST /Andes U., Bogota /Charles U. /Prague, Tech. U. /Prague, Inst. Phys. /San Francisco de Quito U. /Clermont-Ferrand U. /LPSC, Grenoble /Marseille, CPPM /Orsay, LAL /Paris U., VI-VII /DAPNIA, Saclay /Strasbourg, IReS

    2005-07-01

    The D0 experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid-argon calorimeters and central muon detector, remaining from Run I, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to D0.

  14. Heart failure - discharge

    MedlinePlus

    ... Heart failure - overview Heart pacemaker High blood pressure Implantable cardioverter-defibrillator Smoking - tips on how to quit ... ask your doctor How to read food labels Implantable cardioverter defibrillator - discharge Low-salt diet Mediterranean diet ...

  15. Heart failure overview

    MedlinePlus

    ... heart failure: Fast or difficult breathing Leg swelling (edema) Neck veins that stick out (are distended) Sounds ( ... pacemaker High blood pressure Implantable cardioverter-defibrillator Pulmonary edema Stable angina Ventricular assist device Patient Instructions ACE ...

  16. Failure to communicate.

    PubMed

    Fiesta, J

    1998-02-01

    When a medication error is coupled with a communication problem, a patient may experience significant injury. Cases involving communication breakdown, i.e, failure to communicate or listen, are discussed.

  17. Heart failure - tests

    MedlinePlus

    CHF - tests; Congestive heart failure - tests; Cardiomyopathy - tests; HF - tests ... An echocardiogram (Echo) is a test that uses sound waves to create a moving picture of the heart. The picture is much more detailed than a plain ...

  18. Common Cause Failure Modeling

    NASA Technical Reports Server (NTRS)

    Hark, Frank; Britton, Paul; Ring, Robert; Novack, Steven

    2015-01-01

    Space Launch System (SLS) Agenda: Objective; Key Definitions; Calculating Common Cause; Examples; Defense against Common Cause; Impact of varied Common Cause Failure (CCF) and abortability; Response Surface for various CCF Beta; Takeaways.

  19. Evaluation of ultrafiltration failure.

    PubMed

    Korbet, S M

    1998-07-01

    The evaluation of ultrafiltration failure is embarked upon when a patient has persistent problems with symptoms and signs of fluid overload. Fluid overload is a common problem in peritoneal dialysis (PD) patients and the risk of its occurrence increases with time on dialysis. Although often attributed to changes in peritoneal membrane function (membrane failure), there are a number of potential, and frequently more common factors that can contribute to the failure of adequate fluid removal in patients on PD. Many of the causes of ultrafiltration failure may be apparent after an initial informal evaluation. However, if after this the etiology remains unexplained, a systematic approach to the differential diagnosis of this problem can be utilized with the use of the peritoneal equilibration test. Once a diagnosis is confirmed, a logical therapeutic plan can be formulated.

  20. Living with Heart Failure

    MedlinePlus

    ... help you in the future. Follow Your Treatment Plan Treatment can relieve your symptoms and make daily ... or nurse about getting flu and pneumonia vaccines. Plan Ahead If you have heart failure, it's important ...

  1. What Causes Respiratory Failure?

    MedlinePlus

    ... Conditions Causing Respiratory Failure Figure A shows the location of the lungs, airways, diaphragm, rib cage, pulmonary arteries, brain, and spinal cord ... STATEMENT FOIA NO FEAR ACT OIG CONTACT US ...

  2. Genesis Failure Investigation Report

    NASA Technical Reports Server (NTRS)

    Klein, John

    2004-01-01

    The-Genesis mission to collect solar-wind samples and return them to Earth for detailed analysis proceeded successfully for 3.5 years. During reentry on September 8, 2004, a failure in the entry, descent and landing sequence resulted in a crash landing of the Genesis sample return capsule. This document describes the findings of the avionics sub-team that supported the accident investigation of the JPL Failure Review Board.

  3. Heart failure in pregnancy.

    PubMed

    Rutherford, John D

    2012-12-01

    With increasing maternal age and the presence of comorbid conditions such as hypertension, cardiovascular assessment and monitoring is the responsibility of all clinicians caring for pregnant patients. Furthermore, there are specific conditions, such as mitral stenosis, peripartum cardiomyopathy, and preeclampsia, that can be associated with heart failure and secondary maternal (and fetal) mortality and morbidity. The important causes of heart failure in pregnancy are discussed.

  4. Acute renal failure.

    PubMed

    Bellomo, Rinaldo

    2011-10-01

    Acute renal failure (now acute kidney injury) is a common complication of critical illness affecting between 30 and 60% of critically ill patients. The development of a consensus definition (RIFLE--risk, injury, failure, loss, end-stage system) has allowed standardization of reporting and epidemiological work. Multicenter multinational epidemiological studies indicate that sepsis is now the most common cause of acute renal failure in the intensive care unit (ICU) followed by cardiac surgery-associated acute kidney injury. Unfortunately, our understanding of the pathogenesis of acute renal failure in these settings remains limited. Because of such limited understanding, no reproducibly effective therapies have been developed. In addition the diagnosis of acute renal failure still rests upon the detection of changes in serum creatinine, which only occur if more than 50% of glomerular filtration is lost and are often delayed by more than 24 hours. Such diagnostic delays make the implementation of early therapy nearly impossible. In response to these difficulties, there has been a concerted effort to use proteomics to identify novel early biomarkers of acute renal failure. The identification and study of neutrophil gelatinase- associated lipocalin has been an important step in this field. Another area of active interest and investigation relates to the role of intravenous fluid resuscitation and fluid balance. Data from large observational studies and randomized, controlled trials consistently indicate that a positive fluid balance in patients with acute renal failure represents a major independent risk factor for mortality and provides no protection of renal function. The pendulum is clearly swinging away from a fluid-liberal approach to a fluid-conservative approach in these patients. Finally, there is a growing appreciation that acute renal failure may identify patients who are at increased risk of subsequent chronic renal dysfunction and mortality, opening the way

  5. Decompensated heart failure

    PubMed Central

    Mangini, Sandrigo; Pires, Philippe Vieira; Braga, Fabiana Goulart Marcondes; Bacal, Fernando

    2013-01-01

    ABSTRACT Heart failure is a disease with high incidence and prevalence in the population. The costs with hospitalization for decompensated heart failure reach approximately 60% of the total cost with heart failure treatment, and mortality during hospitalization varies according to the studied population, and could achieve values of 10%. In patients with decompensated heart failure, history and physical examination are of great value for the diagnosis of the syndrome, and also can help the physician to identify the beginning of symptoms, and give information about etiology, causes and prognosis of the disease. The initial objective of decompensated heart failure treatment is the hemodynamic and symptomatic improvement preservation and/or improvement of renal function, prevention of myocardial damage, modulation of the neurohormonal and/or inflammatory activation and control of comorbidities that can cause or contribute to progression of the syndrome. According to the clinical-hemodynamic profile, it is possible to establish a rational for the treatment of decompensated heart failure, individualizing the proceedings to be held, leading to reduction in the period of hospitalization and consequently reducing overall mortality. PMID:24136770

  6. Premature ovarian failure.

    PubMed

    Kalantaridou, S N; Davis, S R; Nelson, L M

    1998-12-01

    In 1% of women, premature ovarian failure develops by 40 years of age, a condition causing amenorrhea, infertility, sex steroid deficiency, and elevated gonadotropins. Early loss of ovarian function has significant psychosocial sequelae and major health implications. These young women have a nearly two-fold age-specific increase in mortality rate. Among women with spontaneous premature ovarian failure who have a normal karyotype, half have ovarian follicles remaining in the ovary that function intermittently. Indeed, pregnancies have occurred after the diagnosis of premature ovarian failure. Thus, premature ovarian failure should not be considered as a premature menopause. Young women with this disorder have a 5% to 10% chance for spontaneous pregnancy. Attempts at ovulation induction using various regimens fail to induce ovulation rates greater than those seen in untreated patients; however, oocyte donation for women desiring fertility is an option. Young women with premature ovarian failure need a thorough assessment, sex steroid replacement, and long-term surveillance to monitor therapy. Estrogen-progestin replacement therapy should be instituted as soon as the diagnosis is made. Androgen replacement should also be considered for women with low libido, persistent fatigue, and poor well-being despite taking adequate estrogen replacement. Women with premature ovarian failure should be followed up for the presence of associated autoimmune endocrine disorders such as hypothyroidism, adrenal insufficiency, and diabetes mellitus.

  7. Fast Detector Simulation Using Lelaps, Detector Descriptions in GODL

    SciTech Connect

    Langeveld, Willy; /SLAC

    2005-07-06

    Lelaps is a fast detector simulation program which reads StdHep generator files and produces SIO or LCIO output files. It swims particles through detectors taking into account magnetic fields, multiple scattering and dE/dx energy loss. It simulates parameterized showers in EM and hadronic calorimeters and supports gamma conversions and decays. In addition to three built-in detector configurations, detector descriptions can also be read from files in the new GODL file format.

  8. Large-Area Liquid Scintillation Detector Slab

    NASA Astrophysics Data System (ADS)

    Crouch, M. F.; Gurr, H. S.; Hruschka, A. A.; Jenkins, T. L.; Kropp, W. P.; Reines, P.; Sobel, H.

    The following sections are included: * SUMMARY * INTRODUCTION * DETECTOR RESPONSE FUNCTION F(z) AND EVENT POSITION DETERMINATION * REFINEMENTS IN THE DETECTOR CONFIGURATION DESIGN * DETECTOR PERFORMANCE * APPENDIX * REFERENCES

  9. Gaseous wire detectors

    SciTech Connect

    Va'vra, J.

    1997-08-01

    This article represents a series of three lectures describing topics needed to understand the design of typical gaseous wire detectors used in large high energy physics experiments; including the electrostatic design, drift of electrons in the electric and magnetic field, the avalanche, signal creation, limits on the position accuracy as well as some problems one encounters in practical operations.

  10. Optimizing WIMP directional detectors

    NASA Astrophysics Data System (ADS)

    Green, Anne M.; Morgan, Ben

    2007-03-01

    We study the dependence of the exposure required to directly detect a WIMP directional recoil signal on the capabilities of a directional detector. Specifically we consider variations in the nuclear recoil energy threshold, the background rate, whether the detector measures the recoil momentum vector in two or three dimensions and whether or not the sense of the momentum vector can be determined. We find that the property with the biggest effect on the required exposure is the measurement of the momentum vector sense. If the detector cannot determine the recoil sense, the exposure required is increased by an order of magnitude for 3-d read-out and two orders of magnitude for 2-d read-out. For 2-d read-out the required exposure, in particular if the senses cannot be measured, can be significantly reduced by analyzing the reduced angles with the, time dependent, projected direction of solar motion subtracted. The background rate effectively places a lower limit on the WIMP cross-section to which the detector is sensitive; it will be very difficult to detect WIMPs with a signal rate more than an order of magnitude below the background rate. Lowering the energy threshold also reduces the required exposure, but only for thresholds above 20 keV.

  11. Optimizing WIMP Directional Detectors

    NASA Astrophysics Data System (ADS)

    Green, A. M.; Morgan, B.

    2007-08-01

    We study the dependence of the number of events required to directly detect a WIMP directional recoil signal on the capabilities of a directional detector. We consider variations in the nuclear recoil energy threshold, the background rate, whether the detector measures the recoil momentum vector in 2 or 3 dimensions and whether or not the sense of the momentum vector can be determined. The property with the biggest effect on the required exposure is the measurement of the momentum vector sense. If the detector cannot determine the recoil sense, the exposure required is increased by an order of magnitude for 3-d read-out and two orders of magnitude for 2-d read-out. For 2-d read-out the required exposure, in particular if the senses can not be measured, can be significantly reduced by analyzing the reduced angles with the, time dependent, projected direction of solar motion subtracted. The background rate effectively places a lower limit on the WIMP cross-section to which the detector is sensitive; it will be very difficult to detect WIMPs with a signal rate more than an order of magnitude below the background rate. Lowering the energy threshold also reduces the required exposure, but only for thresholds above 20 keV.

  12. Sensitive hydrogen leak detector

    DOEpatents

    Myneni, Ganapati Rao

    1999-01-01

    A sensitive hydrogen leak detector system using passivation of a stainless steel vacuum chamber for low hydrogen outgassing, a high compression ratio vacuum system, a getter operating at 77.5 K and a residual gas analyzer as a quantitative hydrogen sensor.

  13. Electromagnetic radiation detector

    DOEpatents

    Benson, Jay L.; Hansen, Gordon J.

    1976-01-01

    An electromagnetic radiation detector including a collimating window, a cathode member having a photoelectric emissive material surface angularly disposed to said window whereby radiation is impinged thereon at acute angles, an anode, separated from the cathode member by an evacuated space, for collecting photoelectrons emitted from the emissive cathode surface, and a negatively biased, high transmissive grid disposed between the cathode member and anode.

  14. Detectors and experiments

    NASA Astrophysics Data System (ADS)

    Hauptman, John

    2016-11-01

    The talks in the Program and the Conference parallel sessions make clear that high quality pixel vertex chambers are presently well developed and with continuing improvements (M. Caccia,1 X. Sun,2 M. Stanitzki,3 J. Qian4); that there are at least two major tracking chambers that are well studied, a TPC and silicon-strip chambers (H. Qi,5,6 C. Young,7,8 A. de Roeck9,10); that the energy measurement of photons and electrons is generally very good (H. Yang,11 S. Franchino12); and, that the last remaining detector that has not yet achieved the high precision required for good e+e- physics is the hadronic calorimeter for the measurement of jets, most importantly, jets from the decays of W and Z to quarks (S. Lee,13,14 M. Cascella,15 A. de Roeck16). The relationship of the detectors to physics and the overall design of detectors was addressed and questioned (Y. Gao,17 M. Ruan,18 G. Tonelli,19 H. Zhu,20 M. Mangano,21 C. Quigg22) in addition to precision time measurements in detectors (C. Tully23).

  15. Gas Detectors, Volume 1.

    ERIC Educational Resources Information Center

    Defense Documentation Center, Alexandria, VA.

    The report contains annotated references on gas detectors compiled from the Defense Documentation Center's data bank. The range of the topics deals with detection of toxic propellants, odors, gas leaks, oxygen, etc. Included with the bibliographic reference are the corporate author-monitoring agency, subject, and title indexes. (Author/JR)

  16. Understanding the SNO+ Detector

    SciTech Connect

    Kamdin, K.

    2015-03-24

    SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, in which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.

  17. Photovoltaic radiation detector element

    DOEpatents

    Agouridis, Dimitrios C.

    1983-01-01

    A radiation detector element is formed of a body of semiconductor material, a coating on the body which forms a photovoltaic junction therewith, and a current collector consisting of narrow metallic strips, the aforesaid coating having an opening therein the edge of which closely approaches but is spaced from the current collector strips.

  18. Understanding the SNO+ Detector

    DOE PAGES

    Kamdin, K.

    2015-03-24

    SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, inmore » which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.« less

  19. Optical detector calibrator system

    NASA Technical Reports Server (NTRS)

    Strobel, James P. (Inventor); Moerk, John S. (Inventor); Youngquist, Robert C. (Inventor)

    1996-01-01

    An optical detector calibrator system simulates a source of optical radiation to which a detector to be calibrated is responsive. A light source selected to emit radiation in a range of wavelengths corresponding to the spectral signature of the source is disposed within a housing containing a microprocessor for controlling the light source and other system elements. An adjustable iris and a multiple aperture filter wheel are provided for controlling the intensity of radiation emitted from the housing by the light source to adjust the simulated distance between the light source and the detector to be calibrated. The geared iris has an aperture whose size is adjustable by means of a first stepper motor controlled by the microprocessor. The multiple aperture filter wheel contains neutral density filters of different attenuation levels which are selectively positioned in the path of the emitted radiation by a second stepper motor that is also controlled by the microprocessor. An operator can select a number of detector tests including range, maximum and minimum sensitivity, and basic functionality. During the range test, the geared iris and filter wheel are repeatedly adjusted by the microprocessor as necessary to simulate an incrementally increasing simulated source distance. A light source calibration subsystem is incorporated in the system which insures that the intensity of the light source is maintained at a constant level over time.

  20. The Friendship Detector

    ERIC Educational Resources Information Center

    Cox, Scott

    2012-01-01

    After years of using Rube Goldberg-inspired projects to teach concepts of simple machines, the author sought a comparable project to reinforce electricity lessons in his ninth-grade Science and Technology course. The Friendship Detector gives students a chance to design, test, and build a complex circuit with multiple switches and battery-powered…

  1. The Watchman Detector Design

    NASA Astrophysics Data System (ADS)

    Dazeley, Steven

    2014-03-01

    The Watchman collaboration is proposing a kiloton scale antineutrino detector of reactor-based antineutrinos for non-proliferation purposes. As an added bonus the detector will also have the capability to search for evidence of sterile neutrino oscillation, super-nova antineutrinos and, in a second phase, measure the neutrino mass hierarchy. Despite that fact that KamLAND demonstrated the feasibility of kiloton scale, long distance antineutrino detection with liquid scintillator, similar detectors at the megaton scale remain problematic for environmental, cost and light attenuation reasons. Water, with gadolinium added for neutron sensitivity, may be the detection medium of choice if its efficiency can be shown to be competitive with scintillator. The goal of the Watchman project, therefore, is to demonstrate medium distance reactor antineutrino detection, and thus demonstrate the feasibility of moving to water-based megaton scale antineutrino detectors in the future. In this talk I will describe the scope of the experiment, the physics and engineering challenges involved, the proposed design and the predicted performance of the experimental non-proliferation and high-energy physics program. Lawrence Livermore National Laboratory is operated by Lawrence Livermore National Security, LLC, for the U.S. Department of Energy, National Nuclear Security Administration under Contract DE-AC52-07NA27344. Release number LLNL-ABS-648381.

  2. Sensitive hydrogen leak detector

    DOEpatents

    Myneni, G.R.

    1999-08-03

    A sensitive hydrogen leak detector system is described which uses passivation of a stainless steel vacuum chamber for low hydrogen outgassing, a high compression ratio vacuum system, a getter operating at 77.5 K and a residual gas analyzer as a quantitative hydrogen sensor. 1 fig.

  3. Leak detector uses ultrasonics

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.; Keir, A. R.

    1978-01-01

    Probe located on outer wall of vacuum-jacketed fluid lines detects leaks on inner wall. Probe picks up and amplifies vibrations that occur when gas rushes through leak and converts them to audible signal or CRT display. System is considerably simpler to use than helium leak detectors and allows rapid checks to be made as part of routine maintenance.

  4. Choosing a Motion Detector.

    ERIC Educational Resources Information Center

    Ballard, David M.

    1990-01-01

    Examines the characteristics of three types of motion detectors: Doppler radar, infrared, and ultrasonic wave, and how they are used on school buses to prevent students from being killed by their own school bus. Other safety devices cited are bus crossing arms and a camera monitor system. (MLF)

  5. Understanding the SNO+ Detector

    NASA Astrophysics Data System (ADS)

    Kamdin, K.

    SNO+, a large liquid scintillator experiment, is the successor of the Sudbury Neutrino Observatory (SNO) experiment. The scintillator volume will be loaded with large quantities of 130Te, an isotope that undergoes double beta decay, in order to search for neutrinoless double beta decay. In addition to this search, SNO+ has a broad physics program due to its sensitivity to solar and supernova neutrinos, as well as reactor and geo anti-neutrinos. SNO+ can also place competitive limits on certain modes of invisible nucleon decay during its first phase. The detector is currently undergoing commissioning in preparation for its first phase, in which the detector is filled with ultra pure water. This will be followed by a pure scintillator phase, and then a Tellurium-loaded scintillator phase to search for neutrinoless double beta decay. Here we present the work done to model detector aging, which was first observed during SNO. The aging was found to reduce the optical response of the detector. We also describe early results from electronics calibration of SNO+.

  6. Carbon monoxide detector. [electrochemical gas detector for spacecraft use

    NASA Technical Reports Server (NTRS)

    Holleck, G. L.; Bradspies, J. L.; Brummer, S. B.; Nelsen, L. L.

    1973-01-01

    A sensitive carbon monoxide detector, developed specifically for spacecraft use, is described. An instrument range of 0 to 60 ppm CO in air was devised. The fuel cell type detector is used as a highly sensitive electrolysis cell for electrochemically detecting gases. The concept of an electrochemical CO detector is discussed and the CO oxidation behavior in phosphoric and sulfuric acid electrolytes is reported.

  7. High-resolution ionization detector and array of such detectors

    DOEpatents

    McGregor, Douglas S.; Rojeski, Ronald A.

    2001-01-16

    A high-resolution ionization detector and an array of such detectors are described which utilize a reference pattern of conductive or semiconductive material to form interaction, pervious and measurement regions in an ionization substrate of, for example, CdZnTe material. The ionization detector is a room temperature semiconductor radiation detector. Various geometries of such a detector and an array of such detectors produce room temperature operated gamma ray spectrometers with relatively high resolution. For example, a 1 cm.sup.3 detector is capable of measuring .sup.137 Cs 662 keV gamma rays with room temperature energy resolution approaching 2% at FWHM. Two major types of such detectors include a parallel strip semiconductor Frisch grid detector and the geometrically weighted trapezoid prism semiconductor Frisch grid detector. The geometrically weighted detector records room temperature (24.degree. C.) energy resolutions of 2.68% FWHM for .sup.137 Cs 662 keV gamma rays and 2.45% FWHM for .sup.60 Co 1.332 MeV gamma rays. The detectors perform well without any electronic pulse rejection, correction or compensation techniques. The devices operate at room temperature with simple commercially available NIM bin electronics and do not require special preamplifiers or cooling stages for good spectroscopic results.

  8. Neutron detectors at IPNS

    SciTech Connect

    Crawford, R.K.; Haumann, J.R.; Ostrowski, G.E.

    1990-01-01

    The heart of each time-of-flight neutron scattering instrument is its complement of detectors and the associated encoding and counting electronics. Currently there are ten fully-scheduled neutron scattering instruments in operation at IPNS, with three more instruments under development. Six of these instruments use position-sensitive neutron detectors (PSDs) of various types. These PSDs include a 30 cm {times} 30 cm, {approximately}3 mm resolution, neutron Anger camera area PSD with {sup 6}Li-glass scintillator; a 2.5 cm dia, {approximately}0.7 mm resolution, microchannel-plate area PSD with {sup 6}Li-glass scintillator; a 20 cm {times} 20 cm, {approximately}5 mm resolution, {sup 3}He proportional counter area PSD; a 40 cm {times} 40 cm, {approximately}4 mm resolution, {sup 3}He proportional counter area PSD; a flat 25 cm long, {approximately}1.6 mm resolution, {sup 3}He proportional counter linear PSD; and 160 cylindrical {sup 3}He proportional counter linear PSDs, each of which is 1.27 cm in dia and 60 cm long and has {approximately}14 mm resolution. In addition to these PSDs, {approximately}750 standard cylindrical {sup 3}He proportional counters of various sizes are utilized on IPNS instruments, and {approximately}20 BF{sub 3} pulsed ion chambers are in use as beam monitors. This paper discusses these various detectors and associated electronics, with emphasis on the instrumental specifications and the reasons for the selection of the different types of detectors. Observed performance of these detectors is also discussed. 19 refs., 5 figs., 2 tabs.

  9. Fundamental principles of particle detectors

    SciTech Connect

    Fernow, R.C.

    1988-01-01

    This paper goes through the fundamental physics of particles-matter interactions which is necessary for the detection of these particles with detectors. A listing of 41 concepts and detector principles are given. 14 refs., 11 figs.

  10. Common Cause Failure Modeling

    NASA Technical Reports Server (NTRS)

    Hark, Frank; Britton, Paul; Ring, Rob; Novack, Steven D.

    2015-01-01

    Common Cause Failures (CCFs) are a known and documented phenomenon that defeats system redundancy. CCFS are a set of dependent type of failures that can be caused by: system environments; manufacturing; transportation; storage; maintenance; and assembly, as examples. Since there are many factors that contribute to CCFs, the effects can be reduced, but they are difficult to eliminate entirely. Furthermore, failure databases sometimes fail to differentiate between independent and CCF (dependent) failure and data is limited, especially for launch vehicles. The Probabilistic Risk Assessment (PRA) of NASA's Safety and Mission Assurance Directorate at Marshall Space Flight Center (MFSC) is using generic data from the Nuclear Regulatory Commission's database of common cause failures at nuclear power plants to estimate CCF due to the lack of a more appropriate data source. There remains uncertainty in the actual magnitude of the common cause risk estimates for different systems at this stage of the design. Given the limited data about launch vehicle CCF and that launch vehicles are a highly redundant system by design, it is important to make design decisions to account for a range of values for independent and CCFs. When investigating the design of the one-out-of-two component redundant system for launch vehicles, a response surface was constructed to represent the impact of the independent failure rate versus a common cause beta factor effect on a system's failure probability. This presentation will define a CCF and review estimation calculations. It gives a summary of reduction methodologies and a review of examples of historical CCFs. Finally, it presents the response surface and discusses the results of the different CCFs on the reliability of a one-out-of-two system.

  11. Common Cause Failure Modeling

    NASA Technical Reports Server (NTRS)

    Hark, Frank; Britton, Paul; Ring, Rob; Novack, Steven D.

    2016-01-01

    Common Cause Failures (CCFs) are a known and documented phenomenon that defeats system redundancy. CCFS are a set of dependent type of failures that can be caused by: system environments; manufacturing; transportation; storage; maintenance; and assembly, as examples. Since there are many factors that contribute to CCFs, the effects can be reduced, but they are difficult to eliminate entirely. Furthermore, failure databases sometimes fail to differentiate between independent and CCF (dependent) failure and data is limited, especially for launch vehicles. The Probabilistic Risk Assessment (PRA) of NASA's Safety and Mission Assurance Directorate at Marshal Space Flight Center (MFSC) is using generic data from the Nuclear Regulatory Commission's database of common cause failures at nuclear power plants to estimate CCF due to the lack of a more appropriate data source. There remains uncertainty in the actual magnitude of the common cause risk estimates for different systems at this stage of the design. Given the limited data about launch vehicle CCF and that launch vehicles are a highly redundant system by design, it is important to make design decisions to account for a range of values for independent and CCFs. When investigating the design of the one-out-of-two component redundant system for launch vehicles, a response surface was constructed to represent the impact of the independent failure rate versus a common cause beta factor effect on a system's failure probability. This presentation will define a CCF and review estimation calculations. It gives a summary of reduction methodologies and a review of examples of historical CCFs. Finally, it presents the response surface and discusses the results of the different CCFs on the reliability of a one-out-of-two system.

  12. Subspace Detectors: Efficient Implementation

    SciTech Connect

    Harris, D B; Paik, T

    2006-07-26

    The optimum detector for a known signal in white Gaussian background noise is the matched filter, also known as a correlation detector [Van Trees, 1968]. Correlation detectors offer exquisite sensitivity (high probability of detection at a fixed false alarm rate), but require perfect knowledge of the signal. The sensitivity of correlation detectors is increased by the availability of multichannel data, something common in seismic applications due to the prevalence of three-component stations and arrays. When the signal is imperfectly known, an extension of the correlation detector, the subspace detector, may be able to capture much of the performance of a matched filter [Harris, 2006]. In order to apply a subspace detector, the signal to be detected must be known to lie in a signal subspace of dimension d {ge} 1, which is defined by a set of d linearly-independent basis waveforms. The basis is constructed to span the range of signals anticipated to be emitted by a source of interest. Correlation detectors operate by computing a running correlation coefficient between a template waveform (the signal to be detected) and the data from a window sliding continuously along a data stream. The template waveform and the continuous data stream may be multichannel, as would be true for a three-component seismic station or an array. In such cases, the appropriate correlation operation computes the individual correlations channel-for-channel and sums the result (Figure 1). Both the waveform matching that occurs when a target signal is present and the cross-channel stacking provide processing gain. For a three-component station processing gain occurs from matching the time-history of the signals and their polarization structure. The projection operation that is at the heart of the subspace detector can be expensive to compute if implemented in a straightforward manner, i.e. with direct-form convolutions. The purpose of this report is to indicate how the projection can be

  13. Predictive modeling of infrared detectors and material systems

    NASA Astrophysics Data System (ADS)

    Pinkie, Benjamin

    Detectors sensitive to thermal and reflected infrared radiation are widely used for night-vision, communications, thermography, and object tracking among other military, industrial, and commercial applications. System requirements for the next generation of ultra-high-performance infrared detectors call for increased functionality such as large formats (> 4K HD) with wide field-of-view, multispectral sensitivity, and on-chip processing. Due to the low yield of infrared material processing, the development of these next-generation technologies has become prohibitively costly and time consuming. In this work, it will be shown that physics-based numerical models can be applied to predictively simulate infrared detector arrays of current technological interest. The models can be used to a priori estimate detector characteristics, intelligently design detector architectures, and assist in the analysis and interpretation of existing systems. This dissertation develops a multi-scale simulation model which evaluates the physics of infrared systems from the atomic (material properties and electronic structure) to systems level (modulation transfer function, dense array effects). The framework is used to determine the electronic structure of several infrared materials, optimize the design of a two-color back-to-back HgCdTe photodiode, investigate a predicted failure mechanism for next-generation arrays, and predict the systems-level measurables of a number of detector architectures.

  14. [Heart failure and anemia].

    PubMed

    Reda, S; Motloch, L J; Hoppe, U C

    2013-09-01

    Chronic heart failure has an age-dependent prevalence of 2% and is therefore one of the most frequent diseases in western societies. A reduced hemoglobin concentration according to the definition of the World Health Organization is a common comorbidity affecting more than half of all heart failure patients. Elderly patients, patients suffering from renal impairment and women are more likely to develop anemia but a definitive etiology of anemia is only identified in the minority of cases. Anemia is associated with a poor clinical status and a greater risk of hospitalization and is a predictive factor for increased mortality. The incidence of anemia appears to increase with a poorer functional class. Intravenous iron therapy improves the exercise capacity in patients with systolic heart failure and iron deficiency and is currently being recommended for patients with persistent symptoms despite optimal medical and device therapy. However, erythropoietin-stimulating agents as a treatment for anemia in chronic heart failure have failed to improve clinical outcome in a large randomized trial. In patients with heart failure but with maintained ejection fraction, anemia is also associated with a poor prognosis. Specific therapeutic recommendations for these patients are still not available.

  15. Weld failure detection

    DOEpatents

    Pennell, William E.; Sutton, Jr., Harry G.

    1981-01-01

    Method and apparatus for detecting failure in a welded connection, particrly applicable to not readily accessible welds such as those joining components within the reactor vessel of a nuclear reactor system. A preselected tag gas is sealed within a chamber which extends through selected portions of the base metal and weld deposit. In the event of a failure, such as development of a crack extending from the chamber to an outer surface, the tag gas is released. The environment about the welded area is directed to an analyzer which, in the event of presence of the tag gas, evidences the failure. A trigger gas can be included with the tag gas to actuate the analyzer.

  16. BIOASSAY VESSEL FAILURE ANALYSIS

    SciTech Connect

    Vormelker, P

    2008-09-22

    Two high-pressure bioassay vessels failed at the Savannah River Site during a microwave heating process for biosample testing. Improper installation of the thermal shield in the first failure caused the vessel to burst during microwave heating. The second vessel failure is attributed to overpressurization during a test run. Vessel failure appeared to initiate in the mold parting line, the thinnest cross-section of the octagonal vessel. No material flaws were found in the vessel that would impair its structural performance. Content weight should be minimized to reduce operating temperature and pressure. Outer vessel life is dependent on actual temperature exposure. Since thermal aging of the vessels can be detrimental to their performance, it was recommended that the vessels be used for a limited number of cycles to be determined by additional testing.

  17. Sensor failure and multivariable control for airbreathing propulsion systems. Ph.D. Thesis - Dec. 1979 Final Report

    NASA Technical Reports Server (NTRS)

    Behbehani, K.

    1980-01-01

    A new sensor/actuator failure analysis technique for turbofan jet engines was developed. Three phases of failure analysis, namely detection, isolation, and accommodation are considered. Failure detection and isolation techniques are developed by utilizing the concept of Generalized Likelihood Ratio (GLR) tests. These techniques are applicable to both time varying and time invariant systems. Three GLR detectors are developed for: (1) hard-over sensor failure; (2) hard-over actuator failure; and (3) brief disturbances in the actuators. The probability distribution of the GLR detectors and the detectability of sensor/actuator failures are established. Failure type is determined by the maximum of the GLR detectors. Failure accommodation is accomplished by extending the Multivariable Nyquest Array (MNA) control design techniques to nonsquare system designs. The performance and effectiveness of the failure analysis technique are studied by applying the technique to a turbofan jet engine, namely the Quiet Clean Short Haul Experimental Engine (QCSEE). Single and multiple sensor/actuator failures in the QCSEE are simulated and analyzed and the effects of model degradation are studied.

  18. Event sequence detector

    NASA Technical Reports Server (NTRS)

    Hanna, M. F. (Inventor)

    1973-01-01

    An event sequence detector is described with input units, each associated with a row of bistable elements arranged in an array of rows and columns. The detector also includes a shift register which is responsive to clock pulses from any of the units to sequentially provide signals on its output lines each of which is connected to the bistable elements in a corresponding column. When the event-indicating signal is received by an input unit it provides a clock pulse to the shift register to provide the signal on one of its output lines. The input unit also enables all its bistable elements so that the particular element in the column supplied with the signal from the register is driven to an event-indicating state.

  19. Underwater radiation detector

    DOEpatents

    Kruse, Lyle W.; McKnight, Richard P.

    1986-01-01

    A detector apparatus for differentiating between gamma and neutron radiation is provided. The detector includes a pair of differentially shielded Geiger-Mueller tubes. The first tube is wrapped in silver foil and the second tube is wrapped in lead foil. Both the silver and lead foils allow the passage of gamma rays at a constant rate in a gamma ray only field. When neutrons are present, however, the silver activates and emits beta radiation that is also detected by the silver wrapped Geiger-Mueller tube while the radiation detected by the lead wrapped Geiger-Mueller tube remains constant. The amount of radiation impinging on the separate Geiger-Mueller tubes is then correlated in order to distinguish between the neutron and gamma radiations.

  20. Ionizing radiation detector

    DOEpatents

    Thacker, Louis H.

    1990-01-01

    An ionizing radiation detector is provided which is based on the principle of analog electronic integration of radiation sensor currents in the sub-pico to nano ampere range between fixed voltage switching thresholds with automatic voltage reversal each time the appropriate threshold is reached. The thresholds are provided by a first NAND gate Schmitt trigger which is coupled with a second NAND gate Schmitt trigger operating in an alternate switching state from the first gate to turn either a visible or audible indicating device on and off in response to the gate switching rate which is indicative of the level of radiation being sensed. The detector can be configured as a small, personal radiation dosimeter which is simple to operate and responsive over a dynamic range of at least 0.01 to 1000 R/hr.

  1. Amorphous silicon radiation detectors

    DOEpatents

    Street, Robert A.; Perez-Mendez, Victor; Kaplan, Selig N.

    1992-01-01

    Hydrogenated amorphous silicon radiation detector devices having enhanced signal are disclosed. Specifically provided are transversely oriented electrode layers and layered detector configurations of amorphous silicon, the structure of which allow high electric fields upon application of a bias thereby beneficially resulting in a reduction in noise from contact injection and an increase in signal including avalanche multiplication and gain of the signal produced by incoming high energy radiation. These enhanced radiation sensitive devices can be used as measuring and detection means for visible light, low energy photons and high energy ionizing particles such as electrons, x-rays, alpha particles, beta particles and gamma radiation. Particular utility of the device is disclosed for precision powder crystallography and biological identification.

  2. Stable glow discharge detector

    DOEpatents

    Koo, Jackson C.; Yu, Conrad M.

    2004-05-18

    A highly sensitive electronic ion cell for the measurement of trace elements in He carrier gas which involves glow discharge. A constant wave (CW) stable glow discharge detector which is controlled through a biased resistor, can detect the change of electron density caused by impurities in the He carrier gas by many orders of magnitude larger than that caused by direct ionization or electron capture. The stable glow discharge detector utilizes a floating pseudo-electrode to form a probe in or near the plasma and a solid rod electrode. By using this probe, the large variation of electron density due to trace amounts of impurities can be directly measured. The solid rod electrode provides greater stability and thus easier alignment.

  3. Microwave hemorrhagic stroke detector

    DOEpatents

    Haddad, Waleed S.; Trebes, James E.

    2002-01-01

    The microwave hemorrhagic stroke detector includes a low power pulsed microwave transmitter with a broad-band antenna for producing a directional beam of microwaves, an index of refraction matching cap placed over the patients head, and an array of broad-band microwave receivers with collection antennae. The system of microwave transmitter and receivers are scanned around, and can also be positioned up and down the axis of the patients head. The microwave hemorrhagic stroke detector is a completely non-invasive device designed to detect and localize blood pooling and clots or to measure blood flow within the head or body. The device is based on low power pulsed microwave technology combined with specialized antennas and tomographic methods. The system can be used for rapid, non-invasive detection of blood pooling such as occurs with hemorrhagic stroke in human or animal patients as well as for the detection of hemorrhage within a patient's body.

  4. Microwave hemorrhagic stroke detector

    DOEpatents

    Haddad, Waleed S.; Trebes, James E.

    2007-06-05

    The microwave hemorrhagic stroke detector includes a low power pulsed microwave transmitter with a broad-band antenna for producing a directional beam of microwaves, an index of refraction matching cap placed over the patients head, and an array of broad-band microwave receivers with collection antennae. The system of microwave transmitter and receivers are scanned around, and can also be positioned up and down the axis of the patients head. The microwave hemorrhagic stroke detector is a completely non-invasive device designed to detect and localize blood pooling and clots or to measure blood flow within the head or body. The device is based on low power pulsed microwave technology combined with specialized antennas and tomographic methods. The system can be used for rapid, non-invasive detection of blood pooling such as occurs with hemorrhagic stoke in human or animal patients as well as for the detection of hemorrhage within a patient's body.

  5. Amorphous silicon radiation detectors

    DOEpatents

    Street, R.A.; Perez-Mendez, V.; Kaplan, S.N.

    1992-11-17

    Hydrogenated amorphous silicon radiation detector devices having enhanced signal are disclosed. Specifically provided are transversely oriented electrode layers and layered detector configurations of amorphous silicon, the structure of which allow high electric fields upon application of a bias thereby beneficially resulting in a reduction in noise from contact injection and an increase in signal including avalanche multiplication and gain of the signal produced by incoming high energy radiation. These enhanced radiation sensitive devices can be used as measuring and detection means for visible light, low energy photons and high energy ionizing particles such as electrons, x-rays, alpha particles, beta particles and gamma radiation. Particular utility of the device is disclosed for precision powder crystallography and biological identification. 13 figs.

  6. Terahertz sources and detectors

    NASA Astrophysics Data System (ADS)

    Crowe, Thomas W.; Porterfield, David W.; Hesler, Jeffrey L.; Bishop, William L.; Kurtz, David S.; Hui, Kai

    2005-05-01

    Through the support of the US Army Research Office we are developing terahertz sources and detectors suitable for use in the spectroscopy of chemical and biological materials as well as for use in imaging systems to detect concealed weapons. Our technology relies on nonlinear diodes to translate the functionality achieved at microwave frequencies to the terahertz band. Basic building blocks that have been developed for this application include low-noise mixers, frequency multipliers, sideband generators and direct detectors. These components rely on planar Schottky diodes and integrated diode circuits and are therefore easy to assemble and robust. They require no mechanical tuners to achieve high efficiency and broad bandwidth. This paper will review the range of performance that has been achieved with these terahertz components and briefly discuss preliminary results achieved with a spectroscopy system and the development of sources for imaging systems.

  7. Continuous fluid level detector

    SciTech Connect

    LeVert, F.E.

    1989-02-21

    A fluid level detector is described which consists of: a junctionless thermocouple cable consisting of two thermoelectric elements enclosed in a metallic sheath wherein a negative resistance temperature coefficient insulant is interpositioned between the thermoelectric elements and the inner surface of the metallic sheath thereby providing electrical insulation and thermal energy transfer between the thermoelectric elements; a metallic sheathed resistance heater, which is used to input thermal energy to the fluid level detector; an outer metallic cylindrical tube capable of being sealed on one end, into which the juctionless thermocouple cable and resistance heater are inserted and held in place by mechanically swaging or drawing, to reduce the outer diameter of the metallic cylindrical tube; separate means for supplying electric currents to the thermoelectric elements and to the resistance heater; and electronic and computing means for measuring the loop resistance of the thermoelectric elements with a temporary junction.

  8. Pulsed neutron detector

    DOEpatents

    Robertson, deceased, J. Craig; Rowland, Mark S.

    1989-03-21

    A pulsed neutron detector and system for detecting low intensity fast neutron pulses has a body of beryllium adjacent a body of hydrogenous material the latter of which acts as a beta particle detector, scintillator, and moderator. The fast neutrons (defined as having En>1.5 MeV) react in the beryllium and the hydrogenous material to produce larger numbers of slow neutrons than would be generated in the beryllium itself and which in the beryllium generate hellium-6 which decays and yields beta particles. The beta particles reach the hydrogenous material which scintillates to yield light of intensity related to the number of fast neutrons. A photomultiplier adjacent the hydrogenous material (scintillator) senses the light emission from the scintillator. Utilization means, such as a summing device, sums the pulses from the photo-multiplier for monitoring or other purposes.

  9. Metrology with Unknown Detectors.

    PubMed

    Altorio, Matteo; Genoni, Marco G; Somma, Fabrizia; Barbieri, Marco

    2016-03-11

    The best possible precision is one of the key figures in metrology, but this is established by the exact response of the detection apparatus, which is often unknown. There exist techniques for detector characterization that have been introduced in the context of quantum technologies but apply as well for ordinary classical coherence; these techniques, though, rely on intense data processing. Here, we show that one can make use of the simpler approach of data fitting patterns in order to obtain an estimate of the Cramér-Rao bound allowed by an unknown detector, and we present applications in polarimetry. Further, we show how this formalism provides a useful calculation tool in an estimation problem involving a continuous-variable quantum state, i.e., a quantum harmonic oscillator.

  10. Liquid level detector

    DOEpatents

    Tshishiku, Eugene M.

    2011-08-09

    A liquid level detector for conductive liquids for vertical installation in a tank, the detector having a probe positioned within a sheath and insulated therefrom by a seal so that the tip of the probe extends proximate to but not below the lower end of the sheath, the lower end terminating in a rim that is provided with notches, said lower end being tapered, the taper and notches preventing debris collection and bubble formation, said lower end when contacting liquid as it rises will form an airtight cavity defined by the liquid, the interior sheath wall, and the seal, the compression of air in the cavity preventing liquid from further entry into the sheath and contact with the seal. As a result, the liquid cannot deposit a film to form an electrical bridge across the seal.

  11. Differential optoacoustic absorption detector

    NASA Technical Reports Server (NTRS)

    Shumate, M. S. (Inventor)

    1978-01-01

    A differential optoacoustic absorption detector employed two tapered cells in tandem or in parallel. When operated in tandem, two mirrors were used at one end remote from the source of the beam of light directed into one cell back through the other, and a lens to focus the light beam into the one cell at a principal focus half way between the reflecting mirror. Each cell was tapered to conform to the shape of the beam so that the volume of one was the same as for the other, and the volume of each received maximum illumination. The axes of the cells were placed as close to each other as possible in order to connect a differential pressure detector to the cells with connecting passages of minimum length. An alternative arrangement employed a beam splitter and two lenses to operate the cells in parallel.

  12. Gated strip proportional detector

    DOEpatents

    Morris, Christopher L.; Idzorek, George C.; Atencio, Leroy G.

    1987-01-01

    A gated strip proportional detector includes a gas tight chamber which encloses a solid ground plane, a wire anode plane, a wire gating plane, and a multiconductor cathode plane. The anode plane amplifies the amount of charge deposited in the chamber by a factor of up to 10.sup.6. The gating plane allows only charge within a narrow strip to reach the cathode. The cathode plane collects the charge allowed to pass through the gating plane on a set of conductors perpendicular to the open-gated region. By scanning the open-gated region across the chamber and reading out the charge collected on the cathode conductors after a suitable integration time for each location of the gate, a two-dimensional image of the intensity of the ionizing radiation incident on the detector can be made.

  13. Gated strip proportional detector

    DOEpatents

    Morris, C.L.; Idzorek, G.C.; Atencio, L.G.

    1985-02-19

    A gated strip proportional detector includes a gas tight chamber which encloses a solid ground plane, a wire anode plane, a wire gating plane, and a multiconductor cathode plane. The anode plane amplifies the amount of charge deposited in the chamber by a factor of up to 10/sup 6/. The gating plane allows only charge within a narrow strip to reach the cathode. The cathode plane collects the charge allowed to pass through the gating plane on a set of conductors perpendicular to the open-gated region. By scanning the open-gated region across the chamber and reading out the charge collected on the cathode conductors after a suitable integration time for each location of the gate, a two-dimensional image of the intensity of the ionizing radiation incident on the detector can be made.

  14. Ultrafast neutron detector

    DOEpatents

    Wang, Ching L.

    1987-01-01

    The invention comprises a neutron detector (50) of very high temporal resolution that is particularly well suited for measuring the fusion reaction neutrons produced by laser-driven inertial confinement fusion targets. The detector comprises a biased two-conductor traveling-wave transmission line (54, 56, 58, 68) having a uranium cathode (60) and a phosphor anode (62) as respective parts of the two conductors. A charge line and Auston switch assembly (70, 72, 74) launch an electric field pulse along the transmission line. Neutrons striking the uranium cathode at a location where the field pulse is passing, are enabled to strike the phosphor anode and produce light that is recorded on photographic film (64). The transmission line may be variously configured to achieve specific experimental goals.

  15. Portable Radiation Detectors

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Through a Small Business Innovation Research (SBIR) contract from Kennedy Space Center, General Pneumatics Corporation's Western Research Center satisfied a NASA need for a non-clogging Joule-Thomson cryostat to provide very low temperature cooling for various sensors. This NASA-supported cryostat development played a key part in the development of more portable high-purity geranium gamma-ray detectors. Such are necessary to discern between the radionuclides in medical, fuel, weapon, and waste materials. The outcome of the SBIR project is a cryostat that can cool gamma-ray detectors, without vibration, using compressed gas that can be stored compactly and indefinitely in a standby mode. General Pneumatics also produces custom J-T cryostats for other government, commercial and medical applications.

  16. Integrated Dual Imaging Detector

    NASA Technical Reports Server (NTRS)

    Rust, David M.

    1999-01-01

    A new type of image detector was designed to simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging detector (IDID) consists of a lenslet array and a polarizing beamsplitter bonded to a commercial charge coupled device (CCD). The IDID simplifies the design and operation of solar vector magnetographs and the imaging polarimeters and spectroscopic imagers used, for example, in atmosphere and solar research. When used in a solar telescope, the vector magnetic fields on the solar surface. Other applications include environmental monitoring, robot vision, and medical diagnoses (through the eye). Innovations in the IDID include (1) two interleaved imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 5) electrons per pixel); (3) simultaneous readout and display of both images; and (4) laptop computer signal processing to produce polarization maps in field situations.

  17. Semiconductor radiation detector

    DOEpatents

    Bell, Zane W.; Burger, Arnold

    2010-03-30

    A semiconductor detector for ionizing electromagnetic radiation, neutrons, and energetic charged particles. The detecting element is comprised of a compound having the composition I-III-VI.sub.2 or II-IV-V.sub.2 where the "I" component is from column 1A or 1B of the periodic table, the "II" component is from column 2B, the "III" component is from column 3A, the "IV" component is from column 4A, the "V" component is from column 5A, and the "VI" component is from column 6A. The detecting element detects ionizing radiation by generating a signal proportional to the energy deposited in the element, and detects neutrons by virtue of the ionizing radiation emitted by one or more of the constituent materials subsequent to capture. The detector may contain more than one neutron-sensitive component.

  18. The MICROMEGEM detector

    NASA Astrophysics Data System (ADS)

    Bouhali, O.; De Lentdecker, G.; Dewèze, S.; Udo, F.; Van Doninck, W.; Vander Velde, C.; Van Lancker, L.; Zhukov, V.; Boulogne, I.; Daubie, E.

    2001-02-01

    This article introduces the MICROMEGEM detector, a position-sensitive proportional gas counter produced using advanced Printed Circuit Board (PCB) technology. The detector is equipped with a Gas Electron Multiplier (GEM) foil placed 50 μm above a plane of pick-up strips. The GEM produces a first gas amplification which is extended below the GEM foil by applying a strong electric field between the strips and the lower electrode of the GEM. The array of strips is used for read-out to obtain 1-D positional information. We present results on the gas gain, the energy resolution and the rate capability. The behaviour in an intense beam of 300 MeV/c pions in presence of heavily ionizing particles has also been investigated.

  19. Seismic intrusion detector system

    DOEpatents

    Hawk, Hervey L.; Hawley, James G.; Portlock, John M.; Scheibner, James E.

    1976-01-01

    A system for monitoring man-associated seismic movements within a control area including a geophone for generating an electrical signal in response to seismic movement, a bandpass amplifier and threshold detector for eliminating unwanted signals, pulse counting system for counting and storing the number of seismic movements within the area, and a monitoring system operable on command having a variable frequency oscillator generating an audio frequency signal proportional to the number of said seismic movements.

  20. Gas bubble detector

    NASA Technical Reports Server (NTRS)

    Mount, Bruce E. (Inventor); Burchfield, David E. (Inventor); Hagey, John M. (Inventor)

    1995-01-01

    A gas bubble detector having a modulated IR source focused through a bandpass filter onto a venturi, formed in a sample tube, to illuminate the venturi with modulated filtered IR to detect the presence of gas bubbles as small as 0.01 cm or about 0.004 in diameter in liquid flowing through the venturi. Means are provided to determine the size of any detected bubble and to provide an alarm in the absence of liquid in the sample tube.

  1. Vertex Detector Cable Considerations

    SciTech Connect

    Cooper, William E.; /Fermilab

    2009-02-01

    Vertex detector cable requirements are considered within the context of the SiD concept. Cable material should be limited so that the number of radiation lengths represented is consistent with the material budget. In order to take advantage of the proposed accelerator beam structure and allow cooling by flow of dry gas, 'pulsed power' is assumed. Potential approaches to power distribution, cable paths, and cable design for operation in a 5 T magnetic field are described.

  2. The STEIN Particle Detector

    DTIC Science & Technology

    2015-02-27

    associated with solar disturbances, magnetic storms and magnetospheric substorms. AF-STEIN has several distinct advantages over standard detectors flown on...low-earth- orbit (LEO) satellites. AF-STEIN provides the sensitivity, temporal resolution, energy resolution (~1 keV FWHM), dynamic range, and energy...essentially all important suprathermal (~4 to 200 keV) particle populations associated with solar disturbances, magnetic storms and magnetospheric substorms

  3. Scintillating pad detectors

    SciTech Connect

    Adams, D.; Baumbaugh, B.; Borcherding, F.

    1996-12-31

    We have been investigating the performance of scintillating pad detectors, individual small tiles of scintillator that are read out with wavelength-shifting fibers and visible light photon counters, for application in high luminosity colliding beam experiments such as the D0 Upgrade. Such structures could provide {open_quotes}pixel{close_quotes} type readout over large fiducial volumes for tracking, preshower detection and triggering.

  4. Biological detector and method

    DOEpatents

    Sillerud, Laurel; Alam, Todd M; McDowell, Andrew F

    2013-02-26

    A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

  5. Biological detector and method

    DOEpatents

    Sillerud, Laurel; Alam, Todd M; McDowell, Andrew F

    2014-04-15

    A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

  6. Biological detector and method

    SciTech Connect

    Sillerud, Laurel; Alam, Todd M.; McDowell, Andrew F.

    2015-11-24

    A biological detector includes a conduit for receiving a fluid containing one or more magnetic nanoparticle-labeled, biological objects to be detected and one or more permanent magnets or electromagnet for establishing a low magnetic field in which the conduit is disposed. A microcoil is disposed proximate the conduit for energization at a frequency that permits detection by NMR spectroscopy of whether the one or more magnetically-labeled biological objects is/are present in the fluid.

  7. Detector limitations, STAR

    SciTech Connect

    Underwood, D. G.

    1998-07-13

    Every detector has limitations in terms of solid angle, particular technologies chosen, cracks due to mechanical structure, etc. If all of the presently planned parts of STAR [Solenoidal Tracker At RHIC] were in place, these factors would not seriously limit our ability to exploit the spin physics possible in RHIC. What is of greater concern at the moment is the construction schedule for components such as the Electromagnetic Calorimeters, and the limited funding for various levels of triggers.

  8. Development of Portable Detectors

    SciTech Connect

    2006-12-01

    The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC (the “Contractor”) and Sense Holdings, Inc. (the “Participant”) was for the development of hand-held detectors with high sensitivity and selectivity for the detection of explosives, toxic industrial chemicals and materials, and other materials of interest for security applications. The two parties built a series of demonstration and prototype handheld sensors based upon micoelectromechanical systems (MEMS) with electronic readout.

  9. Laser beam methane detector

    NASA Technical Reports Server (NTRS)

    Hinkley, E. D., Jr.

    1981-01-01

    Instrument uses infrared absorption to determine methane concentration in liquid natural gas vapor. Two sensors measure intensity of 3.39 mm laser beam after it passes through gas; absorption is proportional to concentration of methane. Instrument is used in modeling spread of LNG clouds and as leak detector on LNG carriers and installations. Unit includes wheels for mobility and is both vertically and horizontally operable.

  10. Borehole Muon Detector Development

    NASA Astrophysics Data System (ADS)

    Bonneville, A.; Flygare, J.; Kouzes, R.; Lintereur, A.; Yamaoka, J. A. K.; Varner, G. S.

    2015-12-01

    Increasing atmospheric CO2 concentrations have spurred investigation into carbon sequestration methods. One of the possibilities being considered, storing super-critical CO2 in underground reservoirs, has drawn more attention and pilot projects are being supported worldwide. Monitoring of the post-injection fate of CO2 is of utmost importance. Generally, monitoring options are active methods, such as 4D seismic reflection or pressure measurements in monitoring wells. We propose here to develop a 4-D density tomography of subsurface CO2 reservoirs using cosmic-ray muon detectors deployed in a borehole. Muon detection is a relatively mature field of particle physics and there are many muon detector designs, though most are quite large and not designed for subsurface measurements. The primary technical challenge preventing deployment of this technology in the subsurface is the lack of miniaturized muon-tracking detectors capable of fitting in standard boreholes and that will resist the harsh underground conditions. A detector with these capabilities is being developed by a collaboration supported by the U.S. Department of Energy. Current simulations based on a Monte Carlo modeling code predict that the incoming muon angle can be resolved with an error of approximately two degrees, using either underground or sea level spectra. The robustness of the design comes primarily from the use of scintillating rods as opposed to drift tubes. The rods are arrayed in alternating layers to provide a coordinate scheme. Preliminary testing and measurements are currently being performed to test and enhance the performance of the scintillating rods, in both a laboratory and a shallow underground facility. The simulation predictions and data from the experiments will be presented.

  11. Congestive Heart Failure.

    PubMed

    Scott, Michael C; Winters, Michael E

    2015-08-01

    Patients with acute decompensated heart failure are usually critically ill and require immediate treatment. However, most are not volume overloaded. Emergency department (ED) management is based on rapid initiation of noninvasive positive-pressure ventilation and aggressive titration of nitrates. Afterload reduction with an angiotensin-converting enzyme inhibitor can be considered. A diuretic should not be administered before optimal preload and afterload reduction has been achieved. Short-term inotropic therapy can be considered in select patients with cardiogenic shock and acute decompensated heart failure (ADHF) who fail to respond to standard therapy.

  12. Failure detection and identification

    NASA Technical Reports Server (NTRS)

    Massoumnia, Mohammad-Ali; Verghese, George C.; Willsky, Alan S.

    1989-01-01

    Using the geometric concept of an unobservability subspace, a solution is given to the problem of detecting and identifying control system component failures in linear, time-invariant systems. Conditions are developed for the existence of a causal, linear, time-invariant processor that can detect and uniquely identify a component failure, first for the case where components can fail simultaneously, and then for the case where they fail only one at a time. Explicit design algorithms are provided when these conditions are satisfied. In addition to time-domain solvability conditions, frequency-domain interpretations of the results are given, and connections are drawn with results already available in the literature.

  13. Common Cause Failure Modes

    NASA Technical Reports Server (NTRS)

    Wetherholt, Jon; Heimann, Timothy J.; Anderson, Brenda

    2011-01-01

    High technology industries with high failure costs commonly use redundancy as a means to reduce risk. Redundant systems, whether similar or dissimilar, are susceptible to Common Cause Failures (CCF). CCF is not always considered in the design effort and, therefore, can be a major threat to success. There are several aspects to CCF which must be understood to perform an analysis which will find hidden issues that may negate redundancy. This paper will provide definition, types, a list of possible causes and some examples of CCF. Requirements and designs from NASA projects will be used in the paper as examples.

  14. Hypothyroid acute renal failure.

    PubMed

    Birewar, Sonali; Oppenheimer, Mark; Zawada, Edward T

    2004-03-01

    Muscular disorders and even hypothyroid myopathy with elevated muscle enzymes are commonly seen in hypothyroidism. In this paper, we report a case of acute renal failure in a 35-year old male patient with myalgia. His serum creatinine reached a level of 2.4 mg/dl. Later, his myalgia was found to be due to hypothyroidism with TSH of over 500 uiv/ml. With thyroid replacement therapy, myalgia and his serum creatinine stabilized and subsequently improved. Hypothyroidism, although rare, has been reported as a definite and authentic cause of rhabdomyolysis. As a result, hypothyroidism must be considered in patients presenting with acute renal failure and elevated muscle enzymes.

  15. The DAMPE Neutron Detector

    NASA Astrophysics Data System (ADS)

    Yan, Zhang; Tao, Ma; Yongyi, Huang

    2016-07-01

    The first Chinese space observatory DAMPE (DArk Matter Particle Explorer) was successfully launched on Dec. 17th, 2015. One major scientific object of DAMPE is to measure electrons between 5GeV to 10TeV with excellent energy resolution (1.5% at 800GeV) to search for possible dark matter signatures. The detector consists of four subsystems: a plastic scintillator detector (PSD), a silicon-tungsten tracker (STK), a BGO calorimeter (BGO), and a neutron detector (NUD). The NUD on board DAMPE is designed to detect moderated neutrons via the boron capture of thermal neutrons in boron-doped plastics. Given the fact that hadron showers initiated in the BGO calorimeter by incident nuclei tend to be followed by significantly more neutron activities comparing to electromagnetic cascades triggered by electrons, the NUD provides an additional order of magnitude hadron rejection capability to improve the overall e/p discrimination of DAMPE up to 10 ^{5}. Preliminary analysis of the in-orbit data is given, together with comparisons to the results obtained by a detailed GEANT4 simulation of the NUD instrument.

  16. The STAR PXL detector

    NASA Astrophysics Data System (ADS)

    Contin, G.

    2016-12-01

    The PiXeL detector (PXL) of the STAR experiment at RHIC is the first application of the state-of-the-art thin Monolithic Active Pixel Sensors (MAPS) technology in a collider environment. Designed to extend the STAR measurement capabilities in the heavy flavor domain, it took data in Au+Au collisions, p+p and p+Au collisions at 0√sNN=20 GeV at RHIC, during the period 2014-2016. The PXL detector is based on 50 μm-thin MAPS sensors with a pitch of 20.7 μm. Each sensor includes an array of nearly 1 million pixels, read out in rolling shutter mode in 185.6 μs. The 170 mW/cm2 power dissipation allows for air cooling and contributes to reduce the global material budget to 0.4% radiation length on the innermost layer. Experience and lessons learned from construction and operations will be presented in this paper. Detector performance and results from 2014 Au+Au data analysis, demonstrating the STAR capabilities of charm reconstruction, will be shown.

  17. Detector Apparatus and Method

    NASA Technical Reports Server (NTRS)

    Arndt, G. Dickey (Inventor); Ngo, Phong H. (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor); Dusl, John (Inventor)

    2003-01-01

    Transceiver and methods are included that are especially suitable for detecting metallic materials, such as metallic mines, within an environment. The transceiver includes a digital waveform generator used to transmit a signal into the environment and a receiver that produces a digital received signal. A tracking module preferably compares an in-phase and quadrature transmitted signal with an in-phase and quadrature received signal to produce a spectral transfer function of the magnetic transceiver over a selected range of frequencies. The transceiver initially preferably creates a reference transfer function which is then stored in a memory. Subsequently measured transfer functions will vary depending on the presence of metal in the environment which was not in the environment when the reference transfer function was determined. The system may be utilized in the presence of other antennas, metal, and electronics which may comprise a plastic mine detector for detecting plastic mines. Despite the additional antennas and other metallic materials that may be in the environment due to the plastic mine detector, the magnetic transceiver remains highly sensitive to metallic material which may be located in various portions of the environment and which may be detected by sweeping the detector over ground that may contain metals or mines.

  18. Hybrid superconducting neutron detectors

    SciTech Connect

    Merlo, V.; Lucci, M.; Ottaviani, I.; Salvato, M.; Cirillo, M.; Scherillo, A.; Celentano, G.; Pietropaolo, A.

    2015-03-16

    A neutron detection concept is presented that is based on superconductive niobium (Nb) strips coated by a boron (B) layer. The working principle of the detector relies on the nuclear reaction, {sup 10}B + n → α + {sup 7}Li, with α and Li ions generating a hot spot on the current-biased Nb strip which in turn induces a superconducting-normal state transition. The latter is recognized as a voltage signal which is the evidence of the incident neutron. The above described detection principle has been experimentally assessed and verified by irradiating the samples with a pulsed neutron beam at the ISIS spallation neutron source (UK). It is found that the boron coated superconducting strips, kept at a temperature T = 8 K and current-biased below the critical current I{sub c}, are driven into the normal state upon thermal neutron irradiation. As a result of the transition, voltage pulses in excess of 40 mV are measured while the bias current can be properly modulated to bring the strip back to the superconducting state, thus resetting the detector. Measurements on the counting rate of the device are presented and the basic physical features of the detector are discussed.

  19. Hybrid superconducting neutron detectors

    NASA Astrophysics Data System (ADS)

    Merlo, V.; Salvato, M.; Cirillo, M.; Lucci, M.; Ottaviani, I.; Scherillo, A.; Celentano, G.; Pietropaolo, A.

    2015-03-01

    A neutron detection concept is presented that is based on superconductive niobium (Nb) strips coated by a boron (B) layer. The working principle of the detector relies on the nuclear reaction, 10B + n → α + 7Li, with α and Li ions generating a hot spot on the current-biased Nb strip which in turn induces a superconducting-normal state transition. The latter is recognized as a voltage signal which is the evidence of the incident neutron. The above described detection principle has been experimentally assessed and verified by irradiating the samples with a pulsed neutron beam at the ISIS spallation neutron source (UK). It is found that the boron coated superconducting strips, kept at a temperature T = 8 K and current-biased below the critical current Ic, are driven into the normal state upon thermal neutron irradiation. As a result of the transition, voltage pulses in excess of 40 mV are measured while the bias current can be properly modulated to bring the strip back to the superconducting state, thus resetting the detector. Measurements on the counting rate of the device are presented and the basic physical features of the detector are discussed.

  20. Optical ionization detector

    DOEpatents

    Wuest, Craig R.; Lowry, Mark E.

    1994-01-01

    An optical ionization detector wherein a beam of light is split so that one arm passes through a fiber optics and the other arm passes through a gas-filled region, and uses interferometry to detect density changes in a gas when charged particles pass through it. The gas-filled region of the detector is subjected to a high electric field and as a charged particle traverses this gas region electrons are freed from the cathode and accelerated so as to generate an electron avalanche which is collected on the anode. The gas density is effected by the electron avalanche formation and if the index or refraction is proportional to the gas density the index will change accordingly. The detector uses this index change by modulating the one arm of the split light beam passing through the gas, with respect to the other arm that is passed through the fiber optic. Upon recombining of the beams, interference fringe changes as a function of the index change indicates the passage of charged particles through the gaseous medium.

  1. Optical ionization detector

    DOEpatents

    Wuest, C.R.; Lowry, M.E.

    1994-03-29

    An optical ionization detector wherein a beam of light is split so that one arm passes through a fiber optics and the other arm passes through a gas-filled region, and uses interferometry to detect density changes in a gas when charged particles pass through it. The gas-filled region of the detector is subjected to a high electric field and as a charged particle traverses this gas region electrons are freed from the cathode and accelerated so as to generate an electron avalanche which is collected on the anode. The gas density is effected by the electron avalanche formation and if the index or refraction is proportional to the gas density the index will change accordingly. The detector uses this index change by modulating the one arm of the split light beam passing through the gas, with respect to the other arm that is passed through the fiber optic. Upon recombining of the beams, interference fringe changes as a function of the index change indicates the passage of charged particles through the gaseous medium. 3 figures.

  2. Commissioning the SNO+ detector

    NASA Astrophysics Data System (ADS)

    Descamps, Freija; SNO+ Collaboration

    2016-09-01

    The SNO+ experiment is the successor to the Sudbury Neutrino Observatory (SNO), in which SNO's heavy water is replaced by approximately 780T of liquid scintillator (LAB). The combination of the 2km underground location, the use of ultra-clean materials and the high light-yield of the liquid scintillator means that a low background level and a low energy threshold can be achieved. This creates a new multipurpose neutrino detector with the potential to address a diverse set of physics goals, including the detection of reactor, solar, geo- and supernova neutrinos. A main physics goal of SNO+ is the search for neutrinoless double beta decay. By loading the liquid scintillator with 0.5% of natural Tellurium, resulting in about 1300kg of 130Te (isotopic abundance is slightly over 34%), a competitive sensitivity to the effective neutrino mass can be reached. This talk will present the status of the SNO+ detector, specifically the results and status of the detector commissioning with water.

  3. Sensor readout detector circuit

    DOEpatents

    Chu, D.D.; Thelen, D.C. Jr.

    1998-08-11

    A sensor readout detector circuit is disclosed that is capable of detecting sensor signals down to a few nanoamperes or less in a high (microampere) background noise level. The circuit operates at a very low standby power level and is triggerable by a sensor event signal that is above a predetermined threshold level. A plurality of sensor readout detector circuits can be formed on a substrate as an integrated circuit (IC). These circuits can operate to process data from an array of sensors in parallel, with only data from active sensors being processed for digitization and analysis. This allows the IC to operate at a low power level with a high data throughput for the active sensors. The circuit may be used with many different types of sensors, including photodetectors, capacitance sensors, chemically-sensitive sensors or combinations thereof to provide a capability for recording transient events or for recording data for a predetermined period of time following an event trigger. The sensor readout detector circuit has applications for portable or satellite-based sensor systems. 6 figs.

  4. Sensor readout detector circuit

    DOEpatents

    Chu, Dahlon D.; Thelen, Jr., Donald C.

    1998-01-01

    A sensor readout detector circuit is disclosed that is capable of detecting sensor signals down to a few nanoamperes or less in a high (microampere) background noise level. The circuit operates at a very low standby power level and is triggerable by a sensor event signal that is above a predetermined threshold level. A plurality of sensor readout detector circuits can be formed on a substrate as an integrated circuit (IC). These circuits can operate to process data from an array of sensors in parallel, with only data from active sensors being processed for digitization and analysis. This allows the IC to operate at a low power level with a high data throughput for the active sensors. The circuit may be used with many different types of sensors, including photodetectors, capacitance sensors, chemically-sensitive sensors or combinations thereof to provide a capability for recording transient events or for recording data for a predetermined period of time following an event trigger. The sensor readout detector circuit has applications for portable or satellite-based sensor systems.

  5. Nanowire-based detector

    DOEpatents

    Berggren, Karl K; Hu, Xiaolong; Masciarelli, Daniele

    2014-06-24

    Systems, articles, and methods are provided related to nanowire-based detectors, which can be used for light detection in, for example, single-photon detectors. In one aspect, a variety of detectors are provided, for example one including an electrically superconductive nanowire or nanowires constructed and arranged to interact with photons to produce a detectable signal. In another aspect, fabrication methods are provided, including techniques to precisely reproduce patterns in subsequently formed layers of material using a relatively small number of fabrication steps. By precisely reproducing patterns in multiple material layers, one can form electrically insulating materials and electrically conductive materials in shapes such that incoming photons are redirected toward a nearby electrically superconductive materials (e.g., electrically superconductive nanowire(s)). For example, one or more resonance structures (e.g., comprising an electrically insulating material), which can trap electromagnetic radiation within its boundaries, can be positioned proximate the nanowire(s). The resonance structure can include, at its boundaries, electrically conductive material positioned proximate the electrically superconductive nanowire such that light that would otherwise be transmitted through the sensor is redirected toward the nanowire(s) and detected. In addition, electrically conductive material can be positioned proximate the electrically superconductive nanowire (e.g. at the aperture of the resonant structure), such that light is directed by scattering from this structure into the nanowire.

  6. The STAR Vertex Position Detector

    NASA Astrophysics Data System (ADS)

    Llope, W. J.; Zhou, J.; Nussbaum, T.; Hoffmann, G. W.; Asselta, K.; Brandenburg, J. D.; Butterworth, J.; Camarda, T.; Christie, W.; Crawford, H. J.; Dong, X.; Engelage, J.; Eppley, G.; Geurts, F.; Hammond, J.; Judd, E.; McDonald, D. L.; Perkins, C.; Ruan, L.; Scheblein, J.; Schambach, J. J.; Soja, R.; Xin, K.; Yang, C.

    2014-09-01

    The 2×3 channel pseudo Vertex Position Detector (pVPD) in the STAR experiment at RHIC has been upgraded to a 2×19 channel detector in the same acceptance, called the Vertex Position Detector (VPD). This detector is fully integrated into the STAR trigger system and provides the primary input to the minimum-bias trigger in Au+Au collisions. The information from the detector is used both in the STAR Level-0 trigger and offline to measure the location of the primary collision vertex along the beam pipe and the event "start time" needed by other fast-timing detectors in STAR. The offline timing resolution of single detector channels in full-energy Au+Au collisions is ~100 ps, resulting in a start time resolution of a few tens of picoseconds and a resolution on the primary vertex location of ~1 cm.

  7. State of the art in semiconductor detectors

    SciTech Connect

    Rehak, P. ); Gatti, E. )

    1989-01-01

    The state of the art in semiconductor detectors for elementary particle physics and x-ray astronomy is briefly reviewed. Semiconductor detectors are divided into two groups; classical semiconductor diode detectors; and semiconductor memory detectors. Principles of signal formation for both groups of detectors are described and their performance is compared. New developments of silicon detectors are reported here. 13 refs., 8 figs.

  8. Preventing Early Learning Failure.

    ERIC Educational Resources Information Center

    Sornson, Bob, Ed.

    Noting that thousands of young children with the capacity to experience school success do not because they are unprepared for school learning activities, have experienced physical or emotional setbacks that cause them to be at risk for early learning failure, have never experienced limits on their behavior, or have mild sensory or motor deficits,…

  9. Learning from Failures.

    ERIC Educational Resources Information Center

    Saffran, Murray

    1991-01-01

    Describes mistakes made in trying to change the Nutrition and Digestion section of a medical biochemistry course. Author tried to make the section student taught and reports nine mistakes including the following: ignoring active opposition of colleagues, failure to assess the receptivity of the class to a new form of teaching, and overestimating…

  10. Kidney (Renal) Failure

    MedlinePlus

    ... the ureter (s) or a tube connected to an external drainage bag. Both options are used to unblock the ureters in order to allow proper urine flow from the kidneys if this has been identified as the cause for the renal failure. Surgical treatment such as a urinary stent or ...

  11. Detecting dam failures

    SciTech Connect

    Knarr, C.M.; Barker, T.J.; McKenery, S.F. )

    1994-06-01

    This article describes efforts by Southern California Edison to meet Federal Energy Regulatory Commission requirements for unattended dam monitoring against failure. The topics include a description of the two dam systems, monitoring system design and operation including warning sirens for remote camping areas, and installation of the systems.

  12. Failure in Education

    ERIC Educational Resources Information Center

    Carpenter, Peter

    2009-01-01

    In this article, it is argued that Kurt Hahn felt that it was important for children to experience 'failure' at times and to learn how to cope with it. If this is no longer desirable in the classroom, it ought to be possible to encourage children to be adventurous and "take risks" in a wide range of Outward Bound activities.

  13. Single event effects and their mitigation for the Collider Detector at Fermilab

    SciTech Connect

    Tesarek, Richard J.; D'Auria, Saverio; Dong, Peter; Hocker, Andy; Kordas, Kostas; McGimpsey, Susan; Nicolas, Ludovic; Wallny, Rainer; Schmitt, Wayne; Worm, Steven; /Fermilab /Toronto U. /Glasgow U. /Rutherford /UCLA

    2005-11-01

    We present an overview of radiation induced failures and operational experiences from the Collider Detector at Fermilab (CDF). In our summary, we examine single event effects (SEE) in electronics located in and around the detector. We present results of experiments to identify the sources and composition of the radiation and steps to reduce the rate of SEEs in our electronics. Our studies have led to a better, more complete understanding of the radiation environment in a modern hadron collider experiment.

  14. areaDetector: Software for 2-D Detectors in EPICS

    SciTech Connect

    Rivers, M.

    2011-09-23

    areaDetector is a new EPICS module designed to support 2-D detectors. It is modular C++ code that greatly simplifies the task of writing support for a new detector. It also supports plugins, which receive detector data from the driver and process it in some way. Existing plugins perform Region-Of-Interest extraction and analysis, file saving (in netCDF, HDF, TIFF and JPEG formats), color conversion, and export to EPICS records for image display in clients like ImageJ and IDL. Drivers have now been written for many of the detectors commonly used at synchrotron beamlines, including CCDs, pixel array and amorphous silicon detectors, and online image plates.

  15. Sensor/actuator failure detection and isolation for airbreathing propulsion systems

    NASA Technical Reports Server (NTRS)

    Leininger, G. G.; Behbehani, K.

    1980-01-01

    In this paper, the Generalized Likelihood Ratio (GLR) test is used to detect and isolate sensor and/or actuator failures when a digital computer simulation model of the physical system is available. The input to the GLR detector is an innovation sequence formed by subtracting the model outputs from the sensed outputs. Application of the GLR detector to the General Electric QCSEE turbofan engine demonstrates the utility of the proposed procedure.

  16. Detector Mount Design for IGRINS

    NASA Astrophysics Data System (ADS)

    Oh, Jae Sok; Park, Chan; Cha, Sang-Mok; Yuk, In-Soo; Park, Kwijong; Kim, Kang-Min; Chun, Moo-Young; Ko, Kyeongyeon; Oh, Heeyoung; Jeong, Ueejeong; Nah, Jakyoung; Lee, Hanshin; Jaffe, Daniel T.

    2014-06-01

    The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

  17. The MIC photon counting detector

    NASA Astrophysics Data System (ADS)

    Fordham, J. L. A.; Bone, D. A.; Oldfield, M. K.; Bellis, J. G.; Norton, T. J.

    1992-12-01

    The MIC (Microchannel plate Intensified CCD (Charge Coupled Device)) detector is an advanced performance Micro Channel Plate (MCP) intensified CCD photon counting detector developed for high resolution, high dynamic range, astronomical applications. The heart of the detector is an MCP intensifier developed specifically for photon counting applications. The maximum detector format is 3072 by 2304 pixels. The measured resolution of the detector system is 18 micrometers FWHM at 490 nm. The detector is linear to approximately 1,000,000 events/detector area/sec on a flat field and linear to count rates up to 200 events/object/s on star images. Two versions of the system have been developed. The first for ground based astronomical applications based around a 40 mm diameter intensifier, was proven in trials at a number of large optical telescopes. The second, specifically for the ESA X-Ray Multi Mirror Mission (XMM), where the MIC has been accepted as the blue detector for the incorporated Optical Monitor (OM). For the XMM-OM, the system is based around a 25 mm diameter intensifier. At present, under development, is a 75 mm diameter version of the detector which will have a maximum format of 6144 by 4608 pixels. Details of the MIC detector and its performance are presented.

  18. Gamma Detector Response and Analysis Software - Detector Response Function

    SciTech Connect

    2014-05-13

    GADRAS-DRF uses a Detector Response Function (DRF) to compute the response of gamma-ray detectors incident radiation. The application includes provision for plotting measured and computed spectra and for characterizing detector response parameters based on measurements of a series of calibration sources (e.g., Ba-133, Cs-137, Co-60, and Th-228). An application program interface enables other programs to access the dynamic-link library that is used to compute spectra.

  19. Dynamic failure in brittle solids

    SciTech Connect

    Grady, D.E.

    1994-04-01

    Failure of brittle solids within the extremes of the shock loading environment is not well understood. Recent shock-wave data on compression shear failure and tensile spall failure for selected high-strength ceramics are presented and used to examine the mechanisms of dynamic failure. Energy-based theories are used to bound the measured strength properties. A new concept of failure waves in brittle solids is explored in light of the kinetic processes of high-rate fracture. Classical failure criteria are compared with the present base of dynamic strength data on ceramics.

  20. Moderate temperature detector development

    NASA Technical Reports Server (NTRS)

    Marciniec, J. W.; Briggs, R. J.; Sood, A. K.

    1981-01-01

    P-side backside reflecting constant, photodiode characterization, and photodiode diffusion and G-R currents were investigated in an effort to develop an 8 m to 12 m infrared quantum detector using mercury cadmium telluride. Anodization, phosphorus implantation, and the graded band gap concept were approaches considered for backside formation. Variable thickness diodes were fabricated with a back surface anodic oxide to investigate the effect of this surface preparation on the diffusion limited zero bias impedance. A modeling technique was refined to thoroughly model diode characteristics. Values for the surface recombination velocity in the depletion region were obtained. These values were improved by implementing better surface damage removal techniques.

  1. Advanced Slit Detectors

    DTIC Science & Technology

    1976-12-01

    removed by chemical etching, shown in step 3. The etch solution used is a diluted aqua regia (2 HCl^i^O:! NHO3) . The etch was terminated by quenching...DISTRIBUTION STATEMENT (ol Hi* mbtltmcl •nl«rad In Black 30, II dlftartnl from Htpotl) 18. SUPPLEMENTARY NOTES 19. KEY WORDS (Contlnum on reverse ...source. When 13 : .- ^Mtti m —"—— ’■-■"-—’^ ’-’- ^ - .-».A-.... ■». .^.^.„^^JJ^....^^.^^^. DETECTOR: AD18-L11-#1 FORWARD BIAS fl REVERSE BIAS 1

  2. Wire-inhomogeneity detector

    DOEpatents

    Gibson, G.H.; Smits, R.G.; Eberhard, P.H.

    1982-08-31

    A device for uncovering imperfections in electrical conducting wire, particularly superconducting wire, by detecting variations in eddy currents. Eddy currents effect the magnetic field in a gap of an inductor, contained in a modified commercial ferrite core, through which the wire being tested is passed. A small increase or decrease in the amount of conductive material, such as copper, in a fixed cross section of wire will unbalance a bridge used to measure the impedance of the inductor, tripping a detector and sounding an alarm.

  3. High throughput microcantilever detector

    DOEpatents

    Thundat, Thomas G.; Ferrell, Thomas L.; Hansen, Karolyn M.; Tian, Fang

    2004-07-20

    In an improved uncoated microcantilever detector, the sample sites are placed on a separate semi-conducting substrate and the microcantilever element detects and measures the changes before and after a chemical interaction or hybridization of the sites by sensing differences of phase angle between an alternating voltage applied to the microcantilever element and vibration of the microcantilever element. In another embodiment of the invention, multiple sample sites are on a sample array wherein an array of microcantilever elements detect and measure the change before and after chemical interactions or hybridizations of the sample sites.

  4. Photon detector system

    DOEpatents

    Ekstrom, Philip A.

    1981-01-01

    A photon detector includes a semiconductor device, such as a Schottky barrier diode, which has an avalanche breakdown characteristic. The diode is cooled to cryogenic temperatures to eliminate thermally generated charge carriers from the device. The diode is then biased to a voltage level exceeding the avalanche breakdown threshold level such that, upon receipt of a photon, avalanche breakdown occurs. This breakdown is detected by appropriate circuitry which thereafter reduces the diode bias potential to a level below the avalanche breakdown threshold level to terminate the avalanche condition. Subsequently, the bias potential is reapplied to the diode in preparation for detection of a subsequently received photon.

  5. Pyroelectric demodulating detector

    DOEpatents

    Brocato, Robert W.

    2008-07-08

    A pyroelectric demodulating detector (also termed a pyroelectric demodulator) is disclosed which utilizes an electrical resistor stacked upon a pyroelectric element to demodulate an rf or microwave electrical input signal which is amplitude-modulated (AM). The pyroelectric demodulator, which can be formed as a hybrid or a monolithic device, has applications for use in AM radio receivers. Demodulation is performed by feeding the AM input signal into the resistor and converting the AM input signal into an AM heat signal which is conducted through the pyroelectric element and used to generate an electrical output signal containing AM information from the AM input signal.

  6. Liquid level detector

    DOEpatents

    Grasso, A.P.

    1984-02-21

    A liquid level detector for low pressure boilers. A boiler tank, from which vapor, such as steam, normally exits via a main vent, is provided with a vertical side tube connected to the tank at the desired low liquid level. When the liquid level falls to the level of the side tube vapor escapes therethrough causing heating of a temperature sensitive device located in the side tube, which, for example, may activate a liquid supply means for adding liquid to the boiler tank. High liquid level in the boiler tank blocks entry of vapor into the side tube, allowing the temperature sensitive device to cool, for example, to ambient temperature.

  7. Liquid level detector

    DOEpatents

    Grasso, Albert P.

    1986-01-01

    A liquid level detector for low pressure boilers. A boiler tank, from which apor, such as steam, normally exits via a main vent, is provided with a vertical side tube connected to the tank at the desired low liquid level. When the liquid level falls to the level of the side tube vapor escapes therethrough causing heating of a temperature sensitive device located in the side tube, which, for example, may activate a liquid supply means for adding liquid to the boiler tank. High liquid level in the boiler tank blocks entry of vapor into the side tube, allowing the temperature sensitive device to cool, for example, to ambient temperature.

  8. Flexible composite radiation detector

    DOEpatents

    Cooke, D. Wayne; Bennett, Bryan L.; Muenchausen, Ross E.; Wrobleski, Debra A.; Orler, Edward B.

    2006-12-05

    A flexible composite scintillator was prepared by mixing fast, bright, dense rare-earth doped powdered oxyorthosilicate (such as LSO:Ce, LSO:Sm, and GSO:Ce) scintillator with a polymer binder. The binder is transparent to the scintillator emission. The composite is seamless and can be made large and in a wide variety of shapes. Importantly, the composite can be tailored to emit light in a spectral region that matches the optimum response of photomultipliers (about 400 nanometers) or photodiodes (about 600 nanometers), which maximizes the overall detector efficiency.

  9. Long wavelength infrared detector

    NASA Technical Reports Server (NTRS)

    Vasquez, Richard P. (Inventor)

    1993-01-01

    Long wavelength infrared detection is achieved by a detector made with layers of quantum well material bounded on each side by barrier material to form paired quantum wells, each quantum well having a single energy level. The width and depth of the paired quantum wells, and the spacing therebetween, are selected to split the single energy level with an upper energy level near the top of the energy wells. The spacing is selected for splitting the single energy level into two energy levels with a difference between levels sufficiently small for detection of infrared radiation of a desired wavelength.

  10. Ultraviolet atomic emission detector

    NASA Technical Reports Server (NTRS)

    Braun, W.; Peterson, N. C.; Bass, A. M.; Kurylo, M. J., III (Inventor)

    1972-01-01

    A device and method are provided for performing qualitative and quantitative elemental analysis through the utilization of a vacuum UV chromatographic detector. The method involves the use of a carrier gas at low pressure. The gas carries a sample to a gas chromatograph column; the column output is directed to a microwave cavity. In this cavity, a low pressure microwave discharge produces fragmentation of the compounds present and generates intense atomic emissions in the vacuum ultraviolet. These emissions are isolated by a monochromator and measured by photometer to establish absolute concentration for the elements.

  11. Ionizing Radiation Detector

    DOEpatents

    Wright, Gomez W.; James, Ralph B.; Burger, Arnold; Chinn, Douglas A.

    2003-11-18

    A CdZnTe (CZT) crystal provided with a native CdO dielectric coating to reduce surface leakage currents and thereby, improve the resolution of instruments incorporating detectors using CZT crystals is disclosed. A two step process is provided for forming the dielectric coating which includes etching the surface of a CZT crystal with a solution of the conventional bromine/methanol etch treatment, and passivating the CZT crystal surface with a solution of 10 w/o NH.sub.4 F and 10 w/o H.sub.2 O.sub.2 in water after attaching electrical contacts to the crystal surface.

  12. Response microcantilever thermal detector

    DOEpatents

    Cunningham, Joseph P.; Rajic, Slobodan; Datskos, Panagiotis G.; Evans III, Boyd M.

    2004-10-19

    A "folded leg" thermal detector microcantilever constructed of a substrate with at least one leg interposed between a fixed end and a deflective end, each leg having at least three essentially parallel leg segments interconnected on alternate opposing ends and aligned in a serpentine pattern with only the first leg segment attached to the fixed end and only the last leg segment attached to the deflective end. Alternate leg segment are coated on the pentalever with coating applied to the top of the first, third, and fifth leg segments of each leg and to the bottom of the second and fourth leg segments of each leg.

  13. Infrared detectors for space applications

    NASA Astrophysics Data System (ADS)

    Fick, Wolfgang; Gassmann, Kai Uwe; Haas, Luis-Dieter; Haiml, Markus; Hanna, Stefan; Hübner, Dominique; Höhnemann, Holger; Nothaft, Hans-Peter; Thöt, Richard

    2013-12-01

    The motivation and intended benefits for the use of infrared (IR) detectors for space applications are highlighted. The actual status of state-of-the-art IR detectors for space applications is presented based on some of AIM's currently ongoing focal plane detector module developments covering the spectral range from the short-wavelength IR (SWIR) to the long-wavelength IR (LWIR) and very long-wavelength IR (VLWIR), where both imaging and spectroscopy applications will be addressed. In particular, the integrated detector cooler assemblies for a mid-wavelength IR (MWIR) push-broom imaging satellite mission, for the German hyperspectral satellite mission EnMAP and the IR detectors for the Sentinel 3 SLSTR will be elaborated. Additionally, dedicated detector modules for LWIR/VLWIR sounding, providing the possibility to have two different PVs driven by one ROIC, will be addressed.

  14. Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring

    SciTech Connect

    Hull, Ethan L.; Pehl, Richard H.; Lathrop, James R.; Martin, Gregory N.; Mashburn, R. B.; Miley, Harry S.; Aalseth, Craig E.; Hossbach, Todd W.; Bowyer, Ted W.

    2006-09-21

    Compact maintenance free mechanical cooling systems are being developed to operate large volume (~570 cm3, ~3 kg, 140% or larger) germanium detectors for field applications. We are using a new generation of Stirling-cycle mechanical coolers for operating the very largest volume germanium detectors with absolutely no maintenance or liquid nitrogen requirements. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed five years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring (NEM). The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be utilized. These mechanically cooled germanium detector systems being developed here will provide the largest, most sensitive detectors possible for use with the RASA. To provide such systems, the appropriate technical fundamentals are being researched. Mechanical cooling of germanium detectors has historically been a difficult endeavor. The success or failure of mechanically cooled germanium detectors stems from three main technical issues: temperature, vacuum, and vibration. These factors affect one another. There is a particularly crucial relationship between vacuum and temperature. These factors will be experimentally studied both separately and together to insure a solid understanding of the physical limitations each factor places on a practical mechanically cooled germanium detector system for field use. Using this knowledge, a series of mechanically cooled germanium detector prototype systems are being designed and fabricated. Our collaborators

  15. Precision blood-leak detector with high long-time stability

    NASA Astrophysics Data System (ADS)

    Georgiadis, Christos; Kleuver, Wolfram

    1999-11-01

    With this publication a precision blood-leak-detector is presented. The blood-leak-detector is used for recognition of fractures in the dialyzer of a kidney-machine. It has to detect safely a blood flow of ml/min to exclude any risk for the patient. A lot of systems exist for blood-leak-detection. All of them use the same principle. They detect the light absorption in the dialyze fluid. The actual used detectors are inferior to the new developed sensor in resolution and long-time stability. Regular test of the existing systems and high failure rates are responsible for the high maintenance.

  16. Rad-Hard Silicon Detectors

    NASA Astrophysics Data System (ADS)

    Giorgi, Marco

    2005-06-01

    For the next generation of High Energy Physics (HEP) Experiments silicon microstrip detectors working in harsh radiation environments with excellent performances are necessary. The irradiation causes bulk and surface damages that modify the electrical properties of the detector. Solutions like AC coupled strips, overhanging metal contact, <100> crystal lattice orientation, low resistivity n-bulk and Oxygenated substrate are studied for rad-hard detectors. The paper presents an outlook of these technologies.

  17. Autoimmune premature ovarian failure

    PubMed Central

    2017-01-01

    Premature ovarian failure (POF), also termed as primary ovarian insufficiency (POI), is a highly heterogenous condition affecting 0.5-3.0% of women in childbearing age. These young women comprise quite a formidable group with unique physical and psychological needs that require special attention. Premature ovarian senescence (POS) in all of its forms evolves insidiously as a basically asymptomatic process, leading to complete loss of ovarian function, and POI/POF diagnoses are currently made at relatively late stages. Well-known and well-documented risk factors exist, and the presence or suspicion of autoimmune disorder should be regarded as an important one. Premature ovarian failure is to some degree predictable in its occurrence and should be considered while encountering young women with loss of menstrual regularity, especially when there is a concomitant dysfunction in the immune system. PMID:28250725

  18. Anemia and heart failure.

    PubMed

    O'Meara, Eileen; Murphy, Clare; McMurray, John J V

    2004-12-01

    Over the past few years, anemia has emerged as a powerful independent predictor of adverse outcomes in chronic heart failure (CHF). It affects up to 50% of patients with CHF, depending on the definition of anemia used and on the population studied. Even small reductions in hemoglobin are associated with worse outcome. However, the causes of anemia in CHF remain unclear, although impairment of renal function and inflammatory cytokines are proposed mechanisms. Both may act through impairment of the synthesis or action of erythropoietin. Preliminary studies have demonstrated improvement in symptoms, exercise tolerance, quality of life, and reductions in hospitalizations when patients with severe CHF were treated with erythropoietin. The benefits and the potential risks of such therapies will be further addressed in upcoming larger randomized trials. The recent interest in anemia reflects a new perspective in heart failure therapy, focusing on non-cardiovascular comorbidities.

  19. Observing a failure

    NASA Astrophysics Data System (ADS)

    David, Leonard

    1994-06-01

    Mars Observer was being sent to 'rewrite the book on Mars.' That was the claim of one NASA scientist as the interplanetary robot sat atop a Titan 3 booster that roared skyward from a Cape Canaveral launch pad. On August 21, 1993, only three days before entering Mars orbit, America's first mission to Mars in 17 years fell silent. This article reviews possible causes of this failure.

  20. Triggers of State Failure

    DTIC Science & Technology

    2010-03-01

    insufficiently advanced for precise tipping points to be provided. It is not yet correct to suggest that if GDP falls by X amount in a single year, if...instability (described below). Some indicators will almost always denote impending state failure, such as rapidly decreasing GDP per capita, or an even...expectancy, caloric intake, democracy, GDP per capita, religious diversity and ethnic diversity. The dependent variable is the occurrence of conflict

  1. Structural Crashworthiness and Failure

    DTIC Science & Technology

    1993-04-16

    the equivalent plastic strain reaches a critical failure strain that is a function of the stress triaxiality. An energy density theory is discussed in... SIMONS SRI International, Menlo Park, California 94025, USA W. J. STRONGE Department of Engineering, University of Cambridge, Trumpington Street...chapter covers the theoretical development of the model plus numerical applications that have been verified by carefully designed experiments. 2 THEORY

  2. PAU camera: detectors characterization

    NASA Astrophysics Data System (ADS)

    Casas, Ricard; Ballester, Otger; Cardiel-Sas, Laia; Castilla, Javier; Jiménez, Jorge; Maiorino, Marino; Pío, Cristóbal; Sevilla, Ignacio; de Vicente, Juan

    2012-07-01

    The PAU Camera (PAUCam) [1,2] is a wide field camera that will be mounted at the corrected prime focus of the William Herschel Telescope (Observatorio del Roque de los Muchachos, Canary Islands, Spain) in the next months. The focal plane of PAUCam is composed by a mosaic of 18 CCD detectors of 2,048 x 4,176 pixels each one with a pixel size of 15 microns, manufactured by Hamamatsu Photonics K. K. This mosaic covers a field of view (FoV) of 60 arcmin (minutes of arc), 40 of them are unvignetted. The behaviour of these 18 devices, plus four spares, and their electronic response should be characterized and optimized for the use in PAUCam. This job is being carried out in the laboratories of the ICE/IFAE and the CIEMAT. The electronic optimization of the CCD detectors is being carried out by means of an OG (Output Gate) scan and maximizing it CTE (Charge Transfer Efficiency) while the read-out noise is minimized. The device characterization itself is obtained with different tests. The photon transfer curve (PTC) that allows to obtain the electronic gain, the linearity vs. light stimulus, the full-well capacity and the cosmetic defects. The read-out noise, the dark current, the stability vs. temperature and the light remanence.

  3. LIGO Detector Commissioning

    NASA Astrophysics Data System (ADS)

    Raab, Frederick

    2003-04-01

    The initial LIGO interferometer design was based on more than 20 years of experience with test interferometers, but the increase in scale, new operating environments and extreme technical requirements presented challenges for commissioning. Detector installation began in 1998 with injection optics at Hanford, WA. By 1999, light was resonating in a single 2-km Fabry-Perot arm cavity. Subsequent engineering runs tested stability and analyzed environmental influences, particularly the earth tides and the microseism. By October 2000, the first lock of a kilometer-scale, power recycled Fabry-Perot-Michelson interferometer was obtained, using an automated system to analyze optical signals and reconfigure control loops as the mirrors are drawn into position. The many control loops that minimize length and angle fluctuations of the mirrors relative to the laser light were tuned and noise sources were identified and reduced iteratively as sensitivity improved by several orders of magnitude. Following installation of the last LIGO mirror in 2001, engineering run 7 provided the first triple-coincidence operation of LIGO's interferometers at Hanford and Livingston, LA in early 2002. Clear signals of mirrors recoiling from the Brownian motion of the suspension-wire violin modes first emerged from the noise during science run 1 in September 2002, at approximately the expected amplitude. Detector robustness has steadily improved and uninterrupted locking on a dark fringe for more than a day has been achieved. The support of the US National Science Foundation under Cooperative Agreement No. PHY-0107417 is gratefully acknowledged.

  4. ATLAS Detector Upgrade Prospects

    NASA Astrophysics Data System (ADS)

    Dobre, M.; ATLAS Collaboration

    2017-01-01

    After the successful operation at the centre-of-mass energies of 7 and 8 TeV in 2010-2012, the LHC was ramped up and successfully took data at the centre-of-mass energies of 13 TeV in 2015 and 2016. Meanwhile, plans are actively advancing for a series of upgrades of the accelerator, culminating roughly ten years from now in the high-luminosity LHC (HL-LHC) project, which will deliver of the order of five times the LHC nominal instantaneous luminosity along with luminosity levelling. The ultimate goal is to extend the dataset from about few hundred fb ‑1 expected for LHC running by the end of 2018 to 3000 fb ‑1 by around 2035 for ATLAS and CMS. The challenge of coping with the HL-LHC instantaneous and integrated luminosity, along with the associated radiation levels, requires further major changes to the ATLAS detector. The designs are developing rapidly for a new all-silicon tracker, significant upgrades of the calorimeter and muon systems, as well as improved triggers and data acquisition. ATLAS is also examining potential benefits of extensions to larger pseudorapidity, particularly in tracking and muon systems. This report summarizes various improvements to the ATLAS detector required to cope with the anticipated evolution of the LHC luminosity during this decade and the next. A brief overview is also given on physics prospects with a pp centre-of-mass energy of 14 TeV.

  5. The Galileo Dust Detector

    NASA Technical Reports Server (NTRS)

    Gruen, Eberhard; Fechtig, Hugo; Hanner, Martha S.; Kissel, Jochen; Lindblad, Bertil-Anders; Linkert, Dietmar; Maas, Dieter; Morfill, Gregor E.; Zook, Herbert A.

    1992-01-01

    The Galileo Dust Detector is intended to provide direct observations of dust grains with masses between 10 exp -19 and 10 exp -9 kg in interplanetary space and in the Jovian system, to investigate their physical and dynamical properties as functions of the distances to the sun, to Jupiter and to its satellites, and to study its interaction with the Galilean satellites and the Jovian magnetosphere. The investigation is performed with an instrument that measures the mass, speed, flight direction and electric charge of individual dust particles. It is a multicoincidence detector with a mass sensitivity 1 000 000 times higher than that of previous in situ experiments which measured dust in the outer solar system. The instrument weighs 4.2 kg, consumes 2.4 W, and has a normal data transmission rate of 24 bits/s in nominal spacecraft tracking mode. On December 29, 1989 the instrument was switched-on. After the instrument had been configured to flight conditions cruise science data collection started immediately. In the period to May 18, 1990 at least 168 dust impacts have been recorded. For 81 of these dust grains masses and impact speeds have been determined. First flux values are given.

  6. Optical electromagnetic radiation detector

    NASA Astrophysics Data System (ADS)

    Miceli, W. J.; Ludman, J. E.

    1985-08-01

    An optical electromagnetic radiation detector is invented having a probe for receiving nearby electromagnetic radiation. The probe includes a loop antenna connected to a pair of transparent electrodes deposited on the end surfaces of an electro-optic Fabry-Perot interferometer. When the loop antenna picks up the presence of electromagnetic radiation, a voltage will be developed across the crystal of the electro-optic Fabry-Perot interferometer thereby changing the optical length of the interferometer. A beam of light from a remote location is transmitted through an optical fiber onto the Fabry-Perot interferometer. The change in optical length of the Fabry-Perot interferometer alters the intensity of the beam of light as its is reflected from the Fabry-Perot interferometer back through the optical fiber to the remote location. A beamsplitter directs this reflected beam of light onto an intensity detector in order to provide an output indicative of the variations in intensity. The variations in intensity are directly related to the strength of the electromagnetic radiation received by the loop antenna.

  7. Graphene based GHz detectors

    NASA Astrophysics Data System (ADS)

    Boyd, Anthony K.; El Fatimy, Abdel; Barbara, Paola; Nath, Anindya; Campbell, Paul M.; Myers-Ward, Rachael; Daniels, Kevin; Gaskill, D. Kurt

    Graphene demonstrates great promise as a detector over a wide spectral range especially in the GHz range. This is because absorption is enhanced due to the Drude contribution. In the GHz range there are viable detection mechanisms for graphene devices. With this in mind, two types of GHz detectors are fabricated on epitaxial graphene using a lift off resist-based clean lithography process to produce low contact resistance. Both device types use asymmetry for detection, consistent with recent thoughts of the photothermoelectric effect (PTE) mechanism. The first is an antenna coupled device. It utilizes two dissimilar contact metals and the work function difference produces the asymmetry. The other device is a field effect transistor constructed with an asymmetric top gate that creates a PN junction and facilitates tuning the photovoltaic response. The response of both device types, tested from 100GHz to 170GHz, are reported. This work was sponsored by the U.S. Office of Naval Research (Award Number N000141310865).

  8. Advanced Radiation Detector Development

    SciTech Connect

    The University of Michigan

    1998-07-01

    Since our last progress report, the project at The University of Michigan has continued to concentrate on the development of gamma ray spectrometers fabricated from cadmium zinc telluride (CZT). This material is capable of providing energy resolution that is superior to that of scintillation detectors, while avoiding the necessity for cooling associated with germanium systems. In our past reports, we have described one approach (the coplanar grid electrode) that we have used to partially overcome some of the major limitations on charge collection that is found in samples of CZT. This approach largely eliminates the effect of hole motion in the formation of the output signal, and therefore leads to pulses that depend only on the motion of a single carrier (electrons). Since electrons move much more readily through CZT than do holes, much better energy resolution can be achieved under these conditions. In our past reports, we have described a 1 cm cube CZT spectrometer fitted with coplanar grids that achieved an energy resolution of 1.8% from the entire volume of the crystal. This still represents, to our knowledge, the best energy resolution ever demonstrated in a CZT detector of this size.

  9. Barrier infrared detector

    NASA Technical Reports Server (NTRS)

    Ting, David Z. (Inventor); Khoshakhlagh, Arezou (Inventor); Soibel, Alexander (Inventor); Hill, Cory J. (Inventor); Gunapala, Sarath D. (Inventor)

    2012-01-01

    A superlattice-based infrared absorber and the matching electron-blocking and hole-blocking unipolar barriers, absorbers and barriers with graded band gaps, high-performance infrared detectors, and methods of manufacturing such devices are provided herein. The infrared absorber material is made from a superlattice (periodic structure) where each period consists of two or more layers of InAs, InSb, InSbAs, or InGaAs. The layer widths and alloy compositions are chosen to yield the desired energy band gap, absorption strength, and strain balance for the particular application. Furthermore, the periodicity of the superlattice can be "chirped" (varied) to create a material with a graded or varying energy band gap. The superlattice based barrier infrared detectors described and demonstrated herein have spectral ranges covering the entire 3-5 micron atmospheric transmission window, excellent dark current characteristics operating at least 150K, high yield, and have the potential for high-operability, high-uniformity focal plane arrays.

  10. Chopper-stabilized phase detector

    NASA Technical Reports Server (NTRS)

    Hopkins, P. M.

    1978-01-01

    Phase-detector circuit for binary-tracking loops and other binary-data acquisition systems minimizes effects of drift, gain imbalance, and voltage offset in detector circuitry. Input signal passes simultaneously through two channels where it is mixed with early and late codes that are alternately switched between channels. Code switching is synchronized with polarity switching of detector output of each channel so that each channel uses each detector for half time. Net result is that dc offset errors are canceled, and effect of gain imbalance is simply change in sensitivity.

  11. Detector Background at Muon Colliders

    SciTech Connect

    Mokhov, N.V.; Striganov, S.I.; /Fermilab

    2011-09-01

    Physics goals of a Muon Collider (MC) can only be reached with appropriate design of the ring, interaction region (IR), high-field superconducting magnets, machine-detector interface (MDI) and detector. Results of the most recent realistic simulation studies are presented for a 1.5-TeV MC. It is shown that appropriately designed IR and MDI with sophisticated shielding in the detector have a potential to substantially suppress the background rates in the MC detector. The main characteristics of backgrounds are studied.

  12. In-line ion detector

    SciTech Connect

    Becker, R.; Kester, O.

    2008-02-15

    An in-line particle detector (IPD) uses secondary electrons for the detection of multiply charged ions with low to medium energy (10-10 keV). The ion detector does not physically intercept the ion beam line and is fully transparent to ions without applied voltages. The activation of the detector is performed by applying appropriate voltages to electrodes, which avoids any physical movement. Equipped with a channel electron multiplier, single particle counting is possible as well as measurement of currents. This detector therefore has a large dynamical range from about 10{sup -17} to 10{sup -3} A. The basic principle also allows for ion beam diagnostics.

  13. Burst Populations and Detector Sensitivity

    NASA Technical Reports Server (NTRS)

    Band, David L.

    2003-01-01

    The F(sub T) (peak bolometric photon flux) vs. E(sub p) (peak energy) plane is a powerful tool to compare the burst populations detected by different detectors. Detector sensitivity curves in this plane demonstrate which burst populations the detectors will detect. For example, future CZT-based detectors will show the largest increase in sensitivity for soft bursts, and will be particularly well- suited to study X-ray rich bursts and X-ray Flashes. Identical bursts at different redshifts describe a track in the F(sub T)-E(sub p) plane.

  14. Position-sensitive superconductor detectors

    NASA Astrophysics Data System (ADS)

    Kurakado, M.; Taniguchi, K.

    2016-12-01

    Superconducting tunnel junction (STJ) detectors and superconducting transition- edge sensors (TESs) are representative superconductor detectors having energy resolutions much higher than those of semiconductor detectors. STJ detectors are thin, thereby making it suitable for detecting low-energy X rays. The signals of STJ detectors are more than 100 times faster than those of TESs. By contrast, TESs are microcalorimeters that measure the radiation energy from the change in the temperature. Therefore, signals are slow and their time constants are typically several hundreds of μs. However, TESs possess excellent energy resolutions. For example, TESs have a resolution of 1.6 eV for 5.9-keV X rays. An array of STJs or TESs can be used as a pixel detector. Superconducting series-junction detectors (SSJDs) comprise multiple STJs and a single-crystal substrate that acts as a radiation absorber. SSJDs are also position sensitive, and their energy resolutions are higher than those of semiconductor detectors. In this paper, we give an overview of position-sensitive superconductor detectors.

  15. The MUSE instrument detector system

    NASA Astrophysics Data System (ADS)

    Reiss, Roland; Deiries, Sebastian; Lizon, Jean-Louis; Rupprecht, Gero

    2012-09-01

    The MUSE (Multi Unit Spectroscopic Explorer) instrument (see Bacon et al., this conference) for ESO's Very Large Telescope VLT employs 24 integral field units (spectrographs). Each of these is equipped with its own cryogenically cooled CCD head. The heads are individually cooled by continuous flow cryostats. The detectors used are deep depletion e2v CCD231-84 with 4096x4112 active 15 μm pixels. The MUSE Instrument Detector System is now in the final integration and test phase on the instrument. This paper gives an overview of the architecture and performance of the complex detector system including ESO's New General detector Controllers (NGC) for the 24 science detectors, the detector head electronics and the data acquisition system with Linux Local Control Units. NGC is sub-divided into 4 Detector Front End units each operating 6 CCDs. All CCDs are simultaneously read out through 4 ports to achieve short readout times at low noise levels. All science grade CCDs were thoroughly characterized on ESO's optical detectors testbench facility and the test results processed and documented in a semi-automated, reproducible way. We present the test methodology and the results that fully confirm the feasibility of these detectors for their use in this challenging instrument.

  16. Heart Failure Society of America

    MedlinePlus

    ... hfsa.org Events Calendar>> Copyright © 2017 Heart Failure Society of America. All Rights Reserved 2017 Call for ... for Organ Sharing (UNOS) asks the Heart Failure Society of America (HFSA) members to comment on the ...

  17. Drug Treatment of Cardiac Failure

    PubMed Central

    Achong, M. R.; Kumana, C. R.

    1982-01-01

    Treatment of cardiac failure should first be aimed at reversing or ameliorating the underlying pathological processes. This review highlights the common problems and pitfalls in the use of digoxin, diuretics and vasodilators in patients with cardiac failure. PMID:21289849

  18. Sofradir's recent improvements regarding the reliability and performance of HgCdTe IR detectors

    NASA Astrophysics Data System (ADS)

    Brenière, Xavier; Rubaldo, Laurent; Dupont, Frederic

    2014-06-01

    Sofradir IR detectors are being deployed in a lengthening line of space applications (earth observation, atmospheric observation, scientific missions, etc…), and also in the whole range of tactical applications (portable cameras, missile seekers, land, airborne and naval systems, etc…). Sofradir is taking advantage of these two areas. Firstly, space applications are developing new advances and technologies that can later be introduced in the production of IR detectors for tactical applications, thereby increasing their quality and reliability. In addition, Sofradir can better satisfy space application requirements for failure rates, as these can only be demonstrated with the large number of detectors manufactured, which tactical applications provide. As a result, this approach offers a continuous cycle for reliability of IR detectors, accelerating reliability growth in production, and at the same time meeting requirements for space applications. This paper presents recent improvements introduced in production lines of HgCdTe detectors, that increase performances, image quality, and reliability.

  19. Median filtering algorithms for multichannel detectors

    NASA Astrophysics Data System (ADS)

    Hovhannisyan, A.; Chilingarian, A.

    2011-05-01

    Particle detectors of worldwide networks are continuously measuring various secondary particle fluxes incident on Earth surface. At the Aragats Space Environmental Center (ASEC), the data of 12 cosmic ray particle detectors with a total of ˜280 measuring channels (count rates of electrons, muons and neutrons channels) are sent each minute via wireless bridges to a MySQL database. These time series are used for the different tasks of off-line physical analysis and for online forewarning services. Usually long time series contain several types of errors (gaps due to failures of high or low voltage power supply, spurious spikes due to radio interferences, abrupt changes of mean values of several channels or/and slowly trends in mean values due to aging of electronics components, etc.). To avoid erroneous physical inference and false alarms of alerting systems we introduce offline and online filters to "purify" multiple time-series. In the presented paper we classify possible mistakes in time series and introduce median filtering algorithms for online and off-line "purification" of multiple time-series.

  20. Saturn component failure rate and failure rate modifiers

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Failure mode frequency ratios, environmental adjustment factors, and failure rates for mechanical and electromechanical component families are presented. The failure rates and failure rate modifiers resulted from a series of studies whose purpose was to provide design, tests, reliability, and systems engineers with accurate, up-to-date failure rate information. The results of the studies were achieved through an extensive engineering analysis of the Saturn Program test data and Unsatisfactory Condition Reports (UCR's) and the application of mathematical techniques developed for the studies.

  1. Data Driven Device Failure Prediction

    DTIC Science & Technology

    2016-09-15

    solution is to use statistical machine learning to predict failure. However, since failure is still a relatively rare event, obtaining labelled training...were successful in creating realistic failure conditions that are accurately identified by statistical learning models. iv Acknowledgments Nothing...Jordan v Table of Contents Page Abstract

  2. Your Heart Failure Healthcare Team

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Your Heart Failure Healthcare Team Updated:Sep 28,2016 Patients with ... to the Terms and Conditions and Privacy Policy Heart Failure • Home • About Heart Failure • Causes and Risks for ...

  3. Warning Signs of Heart Failure

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Warning Signs of Heart Failure Updated:Feb 9,2017 By themselves, any one ... faster. This content was last reviewed April 2015. Heart Failure • Home • About Heart Failure • Causes and Risks for ...

  4. Detector developments at DESY.

    PubMed

    Wunderer, Cornelia B; Allahgholi, Aschkan; Bayer, Matthias; Bianco, Laura; Correa, Jonathan; Delfs, Annette; Göttlicher, Peter; Hirsemann, Helmut; Jack, Stefanie; Klyuev, Alexander; Lange, Sabine; Marras, Alessandro; Niemann, Magdalena; Pithan, Florian; Reza, Salim; Sheviakov, Igor; Smoljanin, Sergej; Tennert, Maximilian; Trunk, Ulrich; Xia, Qingqing; Zhang, Jiaguo; Zimmer, Manfred; Das, Dipayan; Guerrini, Nicola; Marsh, Ben; Sedgwick, Iain; Turchetta, Renato; Cautero, Giuseppe; Giuressi, Dario; Menk, Ralf; Khromova, Anastasiya; Pinaroli, Giovanni; Stebel, Luigi; Marchal, Julien; Pedersen, Ulrik; Rees, Nick; Steadman, Paul; Sussmuth, Mark; Tartoni, Nicola; Yousef, Hazem; Hyun, HyoJung; Kim, KyungSook; Rah, Seungyu; Dinapoli, Roberto; Greiffenberg, Dominic; Mezza, Davide; Mozzanica, Aldo; Schmitt, Bernd; Shi, Xintian; Krueger, Hans; Klanner, Robert; Schwandt, Joem; Graafsma, Heinz

    2016-01-01

    With the increased brilliance of state-of-the-art synchrotron radiation sources and the advent of free-electron lasers (FELs) enabling revolutionary science with EUV to X-ray photons comes an urgent need for suitable photon imaging detectors. Requirements include high frame rates, very large dynamic range, single-photon sensitivity with low probability of false positives and (multi)-megapixels. At DESY, one ongoing development project - in collaboration with RAL/STFC, Elettra Sincrotrone Trieste, Diamond, and Pohang Accelerator Laboratory - is the CMOS-based soft X-ray imager PERCIVAL. PERCIVAL is a monolithic active-pixel sensor back-thinned to access its primary energy range of 250 eV to 1 keV with target efficiencies above 90%. According to preliminary specifications, the roughly 10 cm × 10 cm, 3.5k × 3.7k monolithic sensor will operate at frame rates up to 120 Hz (commensurate with most FELs) and use multiple gains within 27 µm pixels to measure 1 to ∼100000 (500 eV) simultaneously arriving photons. DESY is also leading the development of the AGIPD, a high-speed detector based on hybrid pixel technology intended for use at the European XFEL. This system is being developed in collaboration with PSI, University of Hamburg, and University of Bonn. The AGIPD allows single-pulse imaging at 4.5 MHz frame rate into a 352-frame buffer, with a dynamic range allowing single-photon detection and detection of more than 10000 photons at 12.4 keV in the same image. Modules of 65k pixels each are configured to make up (multi)megapixel cameras. This review describes the AGIPD and the PERCIVAL concepts and systems, including some recent results and a summary of their current status. It also gives a short overview over other FEL-relevant developments where the Photon Science Detector Group at DESY is involved.

  5. Neutron detector and fabrication method thereof

    DOEpatents

    Bhandari, Harish B.; Nagarkar, Vivek V.; Ovechkina, Olena E.

    2016-08-16

    A neutron detector and a method for fabricating a neutron detector. The neutron detector includes a photodetector, and a solid-state scintillator operatively coupled to the photodetector. In one aspect, the method for fabricating a neutron detector includes providing a photodetector, and depositing a solid-state scintillator on the photodetector to form a detector structure.

  6. Particle detector spatial resolution

    DOEpatents

    Perez-Mendez, V.

    1992-12-15

    Method and apparatus for producing separated columns of scintillation layer material, for use in detection of X-rays and high energy charged particles with improved spatial resolution is disclosed. A pattern of ridges or projections is formed on one surface of a substrate layer or in a thin polyimide layer, and the scintillation layer is grown at controlled temperature and growth rate on the ridge-containing material. The scintillation material preferentially forms cylinders or columns, separated by gaps conforming to the pattern of ridges, and these columns direct most of the light produced in the scintillation layer along individual columns for subsequent detection in a photodiode layer. The gaps may be filled with a light-absorbing material to further enhance the spatial resolution of the particle detector. 12 figs.

  7. Imaging alpha particle detector

    DOEpatents

    Anderson, David F.

    1985-01-01

    A method and apparatus for detecting and imaging alpha particles sources is described. A conducting coated high voltage electrode (1) and a tungsten wire grid (2) constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source (3) to be quantitatively or qualitatively analyzed. A thin polyester film window (4) allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  8. Imaging alpha particle detector

    DOEpatents

    Anderson, D.F.

    1980-10-29

    A method and apparatus for detecting and imaging alpha particles sources is described. A dielectric coated high voltage electrode and a tungsten wire grid constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source to be quantitatively or qualitatively analyzed. A thin polyester film window allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  9. Porous material neutron detector

    DOEpatents

    Diawara, Yacouba [Oak Ridge, TN; Kocsis, Menyhert [Venon, FR

    2012-04-10

    A neutron detector employs a porous material layer including pores between nanoparticles. The composition of the nanoparticles is selected to cause emission of electrons upon detection of a neutron. The nanoparticles have a maximum dimension that is in the range from 0.1 micron to 1 millimeter, and can be sintered with pores thereamongst. A passing radiation generates electrons at one or more nanoparticles, some of which are scattered into a pore and directed toward a direction opposite to the applied electrical field. These electrons travel through the pore and collide with additional nanoparticles, which generate more electrons. The electrons are amplified in a cascade reaction that occurs along the pores behind the initial detection point. An electron amplification device may be placed behind the porous material layer to further amplify the electrons exiting the porous material layer.

  10. Temperature profile detector

    DOEpatents

    Tokarz, R.D.

    1983-10-11

    Disclosed is a temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles. 8 figs.

  11. Direction sensitive neutron detector

    DOEpatents

    Ahlen, Steven; Fisher, Peter; Dujmic, Denis; Wellenstein, Hermann F.; Inglis, Andrew

    2017-01-31

    A neutron detector includes a pressure vessel, an electrically conductive field cage assembly within the pressure vessel and an imaging subsystem. A pressurized gas mixture of CF.sub.4, .sup.3He and .sup.4He at respective partial pressures is used. The field cage establishes a relatively large drift region of low field strength, in which ionization electrons generated by neutron-He interactions are directed toward a substantially smaller amplification region of substantially higher field strength in which the ionization electrons undergo avalanche multiplication resulting in scintillation of the CF.sub.4 along scintillation tracks. The imaging system generates two-dimensional images of the scintillation patterns and employs track-finding to identify tracks and deduce the rate and direction of incident neutrons. One or more photo-multiplier tubes record the time-profile of the scintillation tracks permitting the determination of the third coordinate.

  12. Temperature profile detector

    DOEpatents

    Tokarz, Richard D.

    1983-01-01

    A temperature profile detector shown as a tubular enclosure surrounding an elongated electrical conductor having a plurality of meltable conductive segments surrounding it. Duplicative meltable segments are spaced apart from one another along the length of the enclosure. Electrical insulators surround these elements to confine molten material from the segments in bridging contact between the conductor and a second electrical conductor, which might be the confining tube. The location and rate of growth of the resulting short circuits between the two conductors can be monitored by measuring changes in electrical resistance between terminals at both ends of the two conductors. Additional conductors and separate sets of meltable segments operational at differing temperatures can be monitored simultaneously for measuring different temperature profiles.

  13. Fiber optic fluid detector

    DOEpatents

    Angel, S. Michael

    1989-01-01

    Particular gases or liquids are detected with a fiber optic element (11, 11a to 11j) having a cladding or coating of a material (23, 23a to 23j) which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector (24, 24a to 24j) may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses.

  14. Fiber optic fluid detector

    DOEpatents

    Angel, S.M.

    1987-02-27

    Particular gases or liquids are detected with a fiber optic element having a cladding or coating of a material which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses. 10 figs.

  15. Laser pulse detector

    DOEpatents

    Mashburn, Douglas N.; Akerman, M. Alfred

    1981-01-01

    A laser pulse detector is provided which is small and inexpensive and has the capability of detecting laser light of any wavelength with fast response (less than 5 nanoseconds rise time). The laser beam is focused onto the receiving end of a graphite rod coaxially mounted within a close-fitting conductive, open-end cylindrical housing so that ablation and electric field breakdown of the resulting plasma occurs due to a bias potential applied between the graphite rod and housing. The pulse produced by the breakdown is transmitted through a matched impedance coaxial cable to a recording device. The cable is connected with its central lead to the graphite rod and its outer conductor to the housing.

  16. Laser pulse detector

    DOEpatents

    Mashburn, D.N.; Akerman, M.A.

    1979-08-13

    A laser pulse detector is provided which is small and inexpensive and has the capability of detecting laser light of any wavelength with fast response (less than 5 nanoseconds rise time). The laser beam is focused onto the receiving end of a graphite rod coaxially mounted within a close-fitting conductive, open-end cylindrical housing so that ablation and electric field breakdown of the resulting plasma occurs due to a bias potential applied between the graphite rod and housing. The pulse produced by the breakdown is transmitted through a matched impedance coaxial cable to a recording device. The cable is connected with its central lead to the graphite rod and its outer conductor to the housing.

  17. Volatile chemical reagent detector

    DOEpatents

    Chen, Liaohai; McBranch, Duncan; Wang, Rong; Whitten, David

    2004-08-24

    A device for detecting volatile chemical reagents based on fluorescence quenching analysis that is capable of detecting neutral electron acceptor molecules. The device includes a fluorescent material, a contact region, a light source, and an optical detector. The fluorescent material includes at least one polymer-surfactant complex. The polymer-surfactant complex is formed by combining a fluorescent ionic conjugated polymer with an oppositely charged surfactant. The polymer-surfactant complex may be formed in a polar solvent and included in the fluorescent material as a solution. Alternatively, the complex may be included in the fluorescent material as a thin film. The use of a polymer-surfactant complex in the fluorescent material allows the device to detect both neutral and ionic acceptor molecules. The use of a polymer-surfactant complex film allows the device and the fluorescent material to be reusable after exposing the fluorescent material to a vacuum for limited time.

  18. Event counting alpha detector

    DOEpatents

    Bolton, Richard D.; MacArthur, Duncan W.

    1996-01-01

    An electrostatic detector for atmospheric radon or other weak sources of alpha radiation. In one embodiment, nested enclosures are insulated from one another, open at the top, and have a high voltage pin inside and insulated from the inside enclosure. An electric field is produced between the pin and the inside enclosure. Air ions produced by collision with alpha particles inside the decay volume defined by the inside enclosure are attracted to the pin and the inner enclosure. With low alpha concentrations, individual alpha events can be measured to indicate the presence of radon or other alpha radiation. In another embodiment, an electrical field is produced between parallel plates which are insulated from a single decay cavity enclosure.

  19. Event counting alpha detector

    DOEpatents

    Bolton, R.D.; MacArthur, D.W.

    1996-08-27

    An electrostatic detector is disclosed for atmospheric radon or other weak sources of alpha radiation. In one embodiment, nested enclosures are insulated from one another, open at the top, and have a high voltage pin inside and insulated from the inside enclosure. An electric field is produced between the pin and the inside enclosure. Air ions produced by collision with alpha particles inside the decay volume defined by the inside enclosure are attracted to the pin and the inner enclosure. With low alpha concentrations, individual alpha events can be measured to indicate the presence of radon or other alpha radiation. In another embodiment, an electrical field is produced between parallel plates which are insulated from a single decay cavity enclosure. 6 figs.

  20. Void/particulate detector

    DOEpatents

    Claytor, Thomas N.; Karplus, Henry B.

    1985-01-01

    Voids and particulates are detected in a flowing stream of fluid contained in a pipe by a detector which includes three transducers spaced about the pipe. A first transducer at a first location on the pipe transmits an ultrasonic signal into the stream. A second transducer detects the through-transmission of the signal at a second location and a third transducer at a third location upstream from the first location detects the back-scattering of the signal from any voids or particulates. To differentiate between voids and particulates a fourth transducer is positioned at a fourth location which is also upstream from the first location. The back-scattered signals are normalized with the through-transmission signal to minimize temperature fluctuations.

  1. Chemical aerosol Raman detector

    NASA Astrophysics Data System (ADS)

    Aggarwal, R. L.; Farrar, L. W.; Di Cecca, S.; Amin, M.; Perkins, B. G.; Clark, M. L.; Jeys, T. H.; Sickenberger, D. W.; D'Amico, F. M.; Emmons, E. D.; Christesen, S. D.; Kreis, R. J.; Kilper, G. K.

    2017-03-01

    A sensitive chemical aerosol Raman detector (CARD) has been developed for the trace detection and identification of chemical particles in the ambient atmosphere. CARD includes an improved aerosol concentrator with a concentration factor of about 40 and a CCD camera for improved detection sensitivity. Aerosolized isovanillin, which is relatively safe, has been used to characterize the performance of the CARD. The limit of detection (SNR = 10) for isovanillin in 15 s has been determined to be 1.6 pg/cm3, which corresponds to 6.3 × 109 molecules/cm3 or 0.26 ppb. While less sensitive, CARD can also detect gases. This paper provides a more detailed description of the CARD hardware and detection algorithm than has previously been published.

  2. Pixelated gamma detector

    SciTech Connect

    Dolinsky, Sergei Ivanovich; Yanoff, Brian David; Guida, Renato; Ivan, Adrian

    2016-12-27

    A pixelated gamma detector includes a scintillator column assembly having scintillator crystals and optical transparent elements alternating along a longitudinal axis, a collimator assembly having longitudinal walls separated by collimator septum, the collimator septum spaced apart to form collimator channels, the scintillator column assembly positioned adjacent to the collimator assembly so that the respective ones of the scintillator crystal are positioned adjacent to respective ones of the collimator channels, the respective ones of the optical transparent element are positioned adjacent to respective ones of the collimator septum, and a first photosensor and a second photosensor, the first and the second photosensor each connected to an opposing end of the scintillator column assembly. A system and a method for inspecting and/or detecting defects in an interior of an object are also disclosed.

  3. Electrophysiological Remodeling in Heart Failure

    PubMed Central

    Wang, Yanggan; Hill, Joseph A.

    2010-01-01

    Heart failure affects nearly 6 million Americans, with a half-million new cases emerging each year. Whereas up to 50% of heart failure patients die of arrhythmia, the diverse mechanisms underlying heart failure-associated arrhythmia are poorly understood. As a consequence, effectiveness of antiarrhythmic pharmacotherapy remains elusive. Here, we review recent advances in our understanding of heart failure-associated molecular events impacting the electrical function of the myocardium. We approach this from an anatomical standpoint, summarizing recent insights gleaned from pre-clinical models and discussing their relevance to human heart failure. PMID:20096285

  4. Space-based detectors

    NASA Astrophysics Data System (ADS)

    Sesana, A.; Weber, W. J.; Killow, C. J.; Perreur-Lloyd, M.; Robertson, D. I.; Ward, H.; Fitzsimons, E. D.; Bryant, J.; Cruise, A. M.; Dixon, G.; Hoyland, D.; Smith, D.; Bogenstahl, J.; McNamara, P. W.; Gerndt, R.; Flatscher, R.; Hechenblaikner, G.; Hewitson, M.; Gerberding, O.; Barke, S.; Brause, N.; Bykov, I.; Danzmann, K.; Enggaard, A.; Gianolio, A.; Vendt Hansen, T.; Heinzel, G.; Hornstrup, A.; Jennrich, O.; Kullmann, J.; Møller-Pedersen, S.; Rasmussen, T.; Reiche, J.; Sodnik, Z.; Suess, M.; Armano, M.; Sumner, T.; Bender, P. L.; Akutsu, T.; Sathyaprakash, B. S.

    2014-12-01

    The parallel session C5 on Space-Based Detectors gave a broad overview over the planned space missions related to gravitational wave detection. Overviews of the revolutionary science to be expected from LISA was given by Alberto Sesana and Sasha Buchman. The launch of LISA Pathfinder (LPF) is planned for 2015. This mission and its payload "LISA Technology Package" will demonstrate key technologies for LISA. In this context, reference masses in free fall for LISA, and gravitational physics in general, was described by William Weber, laser interferometry at the pico-metre level and the optical bench of LPF was presented by Christian Killow and the performance of the LPF optical metrology system by Paul McNamara. While LPF will not yet be sensitive to gravitational waves, it may nevertheless be used to explore fundamental physics questions, which was discussed by Michele Armano. Some parts of the LISA technology that are not going to be demonstrated by LPF, but under intensive development at the moment, were presented by Oliver Jennrich and Oliver Gerberding. Looking into the future, Japan is studying the design of a mid-frequency detector called DECIGO, which was discussed by Tomotada Akutsu. Using atom interferometry for gravitational wave detection has also been recently proposed, and it was critically reviewed by Peter Bender. In the nearer future, the launch of GRACE Follow-On (for Earth gravity observation) is scheduled for 2017, and it will include a Laser Ranging Interferometer as technology demonstrator. This will be the first inter-spacecraft laser interferometer and has many aspects in common with the LISA long arm, as discussed by Andrew Sutton.

  5. Detector Arrays For Infrared Astronomy

    NASA Technical Reports Server (NTRS)

    Mccreight, C. R.; Mckelvey, M. E.; Goebel, J. H.; Anderson, G. M.; Lee, J. H.

    1988-01-01

    Paper describes status of program for developing integrated infrared detectors for astronomy. Program covers variety of detectors, including extrinsic silicon, extrinsic germanium, and indium antimonide devices with hybrid silicon multiplexers. Paper notes for arrays to reach background noise limit in cryogenic telescope, continued reductions in readout noise and dark current needed.

  6. Detector simulation for the SSC

    SciTech Connect

    Price, L.E.

    1991-01-01

    Detector simulation activities for SSC detector designs are described. Topics include the extensive work to date using existing programs. In addition, the several efforts to extend the capabilities of today's programs are described, as the practical and experimental use of new computing platforms for simulation. Finally, progress in the field is compared with the recommendations of the first workshop in this series in 1987.

  7. Micro-channel plate detector

    DOEpatents

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  8. Steam generator tube failures

    SciTech Connect

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  9. Intelligent failure-tolerant control

    NASA Technical Reports Server (NTRS)

    Stengel, Robert F.

    1991-01-01

    An overview of failure-tolerant control is presented, beginning with robust control, progressing through parallel and analytical redundancy, and ending with rule-based systems and artificial neural networks. By design or implementation, failure-tolerant control systems are 'intelligent' systems. All failure-tolerant systems require some degrees of robustness to protect against catastrophic failure; failure tolerance often can be improved by adaptivity in decision-making and control, as well as by redundancy in measurement and actuation. Reliability, maintainability, and survivability can be enhanced by failure tolerance, although each objective poses different goals for control system design. Artificial intelligence concepts are helpful for integrating and codifying failure-tolerant control systems, not as alternatives but as adjuncts to conventional design methods.

  10. Lunar Base Life Support Failures

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.

    2009-01-01

    Dynamic simulation of the lunar outpost habitat life support was undertaken to investigate the impact of life support failures and to investigate responses. Some preparatory static analysis for the Lunar Outpost life support model, an earlier version of the model, and an investigation into the impact of Extravehicular Activity (EVA) were reported previously. (Jones, 2008-01-2184, 2008-01-2017) The earlier model was modified to include possible resupply delays, power failures, recycling system failures, and atmosphere and other material storage failures. Most failures impact the lunar outpost water balance and can be mitigated by reducing water usage. Food solids, nitrogen can be obtained only by resupply from Earth. The most time urgent failure is a lass of carbon dioxide removal capability. Life support failures might be survivable if effective operational solutions are provided in the system design.

  11. The effectiveness of detector combinations.

    PubMed

    Li, Zhenghao; Gong, Weiguo; Nee, A Y C; Ong, S K

    2009-04-27

    In this paper, the performance improvement benefiting from the combination of local feature detectors for image matching and registration is evaluated. Possible combinations of five types of representative interest point detectors and region detectors are integrated into the testing framework. The performance is compared using the number of correspondences and the repeatability rate, as well as an original evaluation criterion named the Reconstruction Similarity (RS), which reflects not only the number of matches, but also the degree of matching error. It is observed that the combination of DoG extremum and MSCR outperforms any single detectors and other detector combinations in most cases. Furthermore, MDSS, a hybrid algorithm for accurate image matching, is proposed. Compared with standard SIFT and GLOH, its average RS rate exceeds more than 3.56%, and takes up even less computational time.

  12. Subminiature infrared detector translation stage

    NASA Technical Reports Server (NTRS)

    Bell, Alan D.

    1989-01-01

    This paper describes a precision subminiature three-axis translation stage used in the GOES Sounder to provide positional adjustment of 12 cooled infrared detectors. Four separate translation stages and detectors are packaged into a detector mechanism which has an overall size of 0.850 x 1.230 x 0.600 inches. Each translation stage is capable of + or - 0.015 inch motion in the X and Y axes and +0.050/-0.025 inch motion in the Z axis with a sensitivity of 0.0002 inches. The function of the detector translation stage allows real time detector signal peaking during Sounder alignment. The translation stage operates in a cryogenic environment under a 10 to the -6th torr vacuum.

  13. Biological Applications of Cryogenic Detectors

    SciTech Connect

    Friedrich, S

    2003-12-03

    High energy resolution and broadband efficiency are enabling the use of cryogenic detectors in biological research. Two areas where they have found initial application are X-ray absorption spectroscopy (XAS) and time-of-flight mass spectrometry (TOF-MS). In synchrotron-based fluorescence-detected XAS cryogenic detectors are used to examine the role of metals in biological systems by measuring their oxidation states and ligand symmetries. In time-of-flight mass spectrometry cryogenic detectors increase the sensitivity for biomolecule detection and identification for masses above {approx}50 kDa, and thus enable TOF-MS on large protein complexes or even entire viruses. More recently, cryogenic detectors have been proposed as optical sensors for fluorescence signals from biomarkers. We discuss the potential for cryogenic detectors in biological research, as well as the challenges the technology faces.

  14. Renal Failure in Pregnancy.

    PubMed

    Balofsky, Ari; Fedarau, Maksim

    2016-01-01

    Renal failure during pregnancy affects both mother and fetus, and may be related to preexisting disease or develop secondary to diseases of pregnancy. Causes include hypovolemia, sepsis, shock, preeclampsia, thrombotic microangiopathies, and renal obstruction. Treatment focuses on supportive measures, while pharmacologic treatment is viewed as second-line therapy, and is more useful in mitigating harmful effects than treating the underlying cause. When supportive measures and pharmacotherapy prove inadequate, dialysis may be required, with the goal being to prolong pregnancy until delivery is feasible. Outcomes and recommendations depend primarily on the underlying cause.

  15. Pharmacoepigenetics in Heart Failure

    PubMed Central

    Mateo Leach, Irene; van der Harst, Pim

    2010-01-01

    Epigenetics studies inheritable changes of genes and gene expression that do not concern DNA nucleotide variation. Such modifications include DNA methylation, several forms of histone modification, and microRNAs. From recent studies, we know not only that genetic changes account for heritable phenotypic variation, but that epigenetic changes also play an important role in the variation of predisposition to disease and to drug response. In this review, we discuss recent evidence of epigenetic changes that play an important role in the development of cardiac hypertrophy and heart failure and may dictate response to therapy. PMID:20424992

  16. Why young elite athletes fear failure: consequences of failure.

    PubMed

    Sagar, Sam S; Lavallee, David; Spray, Christopher M

    2007-09-01

    Fear of failure can have negative effects on children in achievement settings, affecting many aspects of their lives. Perceiving the consequences of failure to be aversive provides the basis for fear of failure, and the anticipation of a threatening outcome elicits fear. Problems attributed to fear of failure in achievement settings are prevalent. Sport is a popular and significant achievement domain for children and adolescents and there is a lack of research on fear of failure in sport among this age group. Therefore, the aim of the present study was to investigate fear of failure in the sport domain among young elite athletes, and to explore their perceptions of the consequences of failure. Interviews were conducted individually with nine athletes aged 14 - 17 years (5 males, 4 females). Analysis identified and organized perceived consequences of failure into themes and categories. Results revealed that the most commonly perceived aversive consequences of failure were diminished perception of self, no sense of achievement, and the emotional cost of failure. These findings are consistent with those reported in adult population, suggesting the potential for generalizing existing results to young elite athletes.

  17. Recent detector developments at SINTEF (industrial presentation)

    NASA Astrophysics Data System (ADS)

    Sundby Avset, Berit; Evensen, Lars; Uri Jensen, Geir; Mo, Sjur; Kari Schjølberg-Henriksen; Westgaard, Trond

    1998-02-01

    Results from SINTEF's research on radiation hardness of silicon detectors, thin silicon detectors, silicon drift devices, reach-through avalanche photodiodes, and detectors with thin dead layers are presented.

  18. Heart Failure Readmission Reduction.

    PubMed

    Drozda, Joseph P; Smith, Donna A; Freiman, Paul C; Pursley, Janet; VanSlette, Jeffrey A; Smith, Timothy R

    Little is known regarding effectiveness of readmission reduction programs over time. The Heart Failure Management Program (HFMP) of St. John's Physician Group Practice (PGP) Demonstration provided an opportunity to assess outcomes over an extended period. Data from an electronic health record, an inpatient database, a disease registry, and the Social Security Death Master File were analyzed for patients admitted with heart failure (HF) for 5 years before (Period 1) and 5 years after (Period 2) inception of PGP. HF admissions decreased (Period 1, 58.3/month; Period 2, 52.4/month, P = .007). Thirty-day all-cause readmission rate dropped from Period 1 (annual average 18.8% [668/3545]) to year 1 of Period 2 (16.9% [136/804], P = .04) and remained stable thereafter (annual average 16.8% [589/3503]). Thirty-day mortality rate was flat throughout. HFMP was associated with decreased readmissions, primarily related to outpatient case management, while mortality remained stable.

  19. Scaling of structural failure

    SciTech Connect

    Bazant, Z.P.; Chen, Er-Ping

    1997-01-01

    This article attempts to review the progress achieved in the understanding of scaling and size effect in the failure of structures. Particular emphasis is placed on quasibrittle materials for which the size effect is complicated. Attention is focused on three main types of size effects, namely the statistical size effect due to randomness of strength, the energy release size effect, and the possible size effect due to fractality of fracture or microcracks. Definitive conclusions on the applicability of these theories are drawn. Subsequently, the article discusses the application of the known size effect law for the measurement of material fracture properties, and the modeling of the size effect by the cohesive crack model, nonlocal finite element models and discrete element models. Extensions to compression failure and to the rate-dependent material behavior are also outlined. The damage constitutive law needed for describing a microcracked material in the fracture process zone is discussed. Various applications to quasibrittle materials, including concrete, sea ice, fiber composites, rocks and ceramics are presented.

  20. Insomnia Self-Management in Heart Failure

    ClinicalTrials.gov

    2016-12-07

    Cardiac Failure; Heart Failure; Congestive Heart Failure; Heart Failure, Congestive; Sleep Initiation and Maintenance Disorders; Chronic Insomnia; Disorders of Initiating and Maintaining Sleep; Fatigue; Pain; Depressive Symptoms; Sleep Disorders; Anxiety

  1. Digital radiography: Present detectors and future developments

    SciTech Connect

    Perez-Mendez, V.

    1990-08-01

    Present detectors for digital radiography are of two classes: real time detectors and storage (non real time) types. Present real time detectors consist of image intensifier tubes with an internal cesium iodide layer x-ray converter. Non real time detectors involve linear sweep arrays or storage detectors such as film. Future detectors discussed here can be of both types utilizing new technologies such as hydrogenated amorphous silicon photodiode arrays coupled to thin film transistor arrays. 17 refs., 10 figs.

  2. Plastic neutron detectors.

    SciTech Connect

    Wilson, Tiffany M.S; King, Michael J.; Doty, F. Patrick

    2008-12-01

    This work demonstrated the feasibility and limitations of semiconducting {pi}-conjugated organic polymers for fast neutron detection via n-p elastic scattering. Charge collection in conjugated polymers in the family of substituted poly(p-phenylene vinylene)s (PPV) was evaluated using band-edge laser and proton beam ionization. These semiconducting materials can have high H/C ratio, wide bandgap, high resistivity and high dielectric strength, allowing high field operation with low leakage current and capacitance noise. The materials can also be solution cast, allowing possible low-cost radiation detector fabrication and scale-up. However, improvements in charge collection efficiency are necessary in order to achieve single particle detection with a reasonable sensitivity. The work examined processing variables, additives and environmental effects. Proton beam exposure was used to verify particle sensitivity and radiation hardness to a total exposure of approximately 1 MRAD. Conductivity exhibited sensitivity to temperature and humidity. The effects of molecular ordering were investigated in stretched films, and FTIR was used to quantify the order in films using the Hermans orientation function. The photoconductive response approximately doubled for stretch-aligned films with the stretch direction parallel to the electric field direction, when compared to as-cast films. The response was decreased when the stretch direction was orthogonal to the electric field. Stretch-aligned films also exhibited a significant sensitivity to the polarization of the laser excitation, whereas drop-cast films showed none, indicating improved mobility along the backbone, but poor {pi}-overlap in the orthogonal direction. Drop-cast composites of PPV with substituted fullerenes showed approximately a two order of magnitude increase in photoresponse, nearly independent of nanoparticle concentration. Interestingly, stretch-aligned composite films showed a substantial decrease in

  3. Bubble detector investigations in China.

    PubMed

    Guo, Shi-Lun

    2006-01-01

    Investigation on bubble detectors started in China in 1989. Five types of bubble detectors have been developed, with LET thresholds ranging from 0.05 to 6.04 MeV mg(-1) cm(2) at 25 degrees C. The neutron response of bubble detectors made with freon-12 has been investigated with mono-energetic neutrons from 20 keV to 19 MeV. Its effective threshold energy for neutron detection is approximately 100 keV at 28 degrees C. The response above this threshold is approximately 1.5 x 10(-4) (bubble cm(-2))/(n cm(-2)). Bubble detectors are unique not only for neutron dosimetry but also for monitoring and identifying high-energy heavy ions such as cosmic radiation in the space. High-energy heavy ion tracks in large size bubble detectors have been investigated in cooperation with scientists in Japan. The key parameter behind the thresholds of bubble detectors for track registration is the critical rate of energy loss. Three approaches to identify high-energy heavy ions with bubble detectors are suggested.

  4. Space Radiation Detector with Spherical Geometry

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D. (Inventor); Fralick, Gustave C. (Inventor); Wrbanek, Susan Y. (Inventor)

    2011-01-01

    A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

  5. Space Radiation Detector with Spherical Geometry

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D. (Inventor); Fralick, Gustave C. (Inventor); Wrbanek, Susan Y. (Inventor)

    2012-01-01

    A particle detector is provided, the particle detector including a spherical Cherenkov detector, and at least one pair of detector stacks. In an embodiment of the invention, the Cherenkov detector includes a sphere of ultraviolet transparent material, coated by an ultraviolet reflecting material that has at least one open port. The Cherenkov detector further includes at least one photodetector configured to detect ultraviolet light emitted from a particle within the sphere. In an embodiment of the invention, each detector stack includes one or more detectors configured to detect a particle traversing the sphere.

  6. Optimal fine ϕ-slicing for single-photon-counting pixel detectors

    PubMed Central

    Mueller, Marcus; Wang, Meitian; Schulze-Briese, Clemens

    2012-01-01

    The data-collection parameters used in a macromolecular diffraction experiment have a strong impact on data quality. A careful choice of parameters leads to better data and can make the difference between success and failure in phasing attempts, and will also result in a more accurate atomic model. The selection of parameters has to account for the application of the data in various phasing methods or high-resolution refinement. Furthermore, experimental factors such as crystal characteristics, available experiment time and the properties of the X-ray source and detector have to be considered. For many years, CCD detectors have been the prevalent type of detectors used in macromolecular crystallography. Recently, hybrid pixel X-ray detectors that operate in single-photon-counting mode have become available. These detectors have fundamentally different characteristics compared with CCD detectors and different data-collection strategies should be applied. Fine ϕ-slicing is a strategy that is particularly well suited to hybrid pixel detectors because of the fast readout time and the absence of readout noise. A large number of data sets were systematically collected from crystals of four different proteins in order to investigate the benefit of fine ϕ-­slicing on data quality with a noise-free detector. The results show that fine ϕ-slicing can substantially improve scaling statistics and anomalous signal provided that the rotation angle is comparable to half the crystal mosaicity. PMID:22194332

  7. MCP detector development for use in Nab detector characterization

    NASA Astrophysics Data System (ADS)

    Klassen, Wolfgang; Nab Collaboration

    2016-09-01

    The ``Nab'' collaboration will perform a precise measurement of the neutron beta decay parameters ``a'' and ``b'', which constitutes a test for physics beyond the standard model. The experiment makes use of the fundamental physics cold neutron beamline at the Spallation Neutron Source at the Fundamental Neutron Physics Beam Line. This experiment requires very efficient and precise detection of low energy (30 keV) protons with large area Si detectors. To this end, a 30 keV proton source has been built at the University of Manitoba to characterize the Si detector with respect to a custom large area (150mm x 150mm) microchannel plate detector, with know detection efficiency. This poster will present the development of the microchannel plate detector, the theory behind its operation, and its implementation at the University of Manitoba.

  8. SSC muon detector group report

    SciTech Connect

    Carlsmith, D.; Groom, D.; Hedin, D.; Kirk, T.; Ohsugi, T.; Reeder, D.; Rosner, J.; Wojcicki, S.

    1986-01-01

    We report here on results from the Muon Detector Group which met to discuss aspects of muon detection for the reference 4..pi.. detector models put forward for evaluation at the Snowmass 1986 Summer Study. We report on: suitable overall detector geometry; muon energy loss mechanisms; muon orbit determination; muon momentum and angle measurement resolution; raw muon rates and trigger concepts; plus we identify SSC physics for which muon detection will play a significant role. We conclude that muon detection at SSC energies and luminosities is feasible and will play an important role in the evolution of physics at the SSC.

  9. Seal system with integral detector

    DOEpatents

    Fiarman, S.

    1982-08-12

    A seal system is disclosed for materials where security is of the essence, such as nuclear materials. The seal is tamper-indicating, indicates changes in environmental conditions that evidence attempts to bypass the seal, is unique and cost effective. The seal system is comprised of a seal where an optical signal is transmitted through a loop, with a detector to read said signal, and one or more additional detectors designed to detect environmental changes, these detectors being operatively associated with the seal so that detection of a break in the optical signal or detection of environmental changes will cause an observable change in the seal.

  10. Seal system with integral detector

    DOEpatents

    Fiarman, Sidney

    1985-01-01

    There is disclosed a seal system for materials where security is of the essence, such as nuclear materials, which is tamper-indicating, which indicates changes in environmental conditions that evidence attempts to by-pass the seal, which is unique and cost effective, said seal system comprised of a seal where an optical signal is transmitted through a loop, with a detector to read said signal, and one or more additional detectors designed to detect environmental changes, these detectors being operatively associated with the seal so that detection of a break in the optical signal or detection of environmental changes will cause an observable change in the seal.

  11. Detector materials: germanium and silicon

    SciTech Connect

    Haller, E.E.

    1981-11-01

    This article is a summary of a short course lecture given in conjunction with the 1981 Nuclear Science Symposium. The basic physical properties of elemental semiconductors are reviewed. The interaction of energetic radiation with matter is discussed in order to develop a feeling for the appropriate semiconductor detector dimensions. The extremely low net dopant concentrations which are required are derived directly from the detector dimensions. A survey of the more recent techniques which have been developed for the analysis of detector grade semiconductor single crystals is presented.

  12. The CDF Silicon Vertex Detector

    SciTech Connect

    Tkaczyk, S.; Carter, H.; Flaugher, B.

    1993-09-01

    A silicon strip vertex detector was designed, constructed and commissioned at the CDF experiment at the Tevatron collider at Fermilab. The mechanical design of the detector, its cooling and monitoring are presented. The front end electronics employing a custom VLSI chip, the readout electronics and various components of the SVX system are described. The system performance and the experience with the operation of the detector in the radiation environment are discussed. The device has been taking colliding beams data since May of 1992, performing at its best design specifications and enhancing the physics program of CDF.

  13. Requirements on high resolution detectors

    SciTech Connect

    Koch, A.

    1997-02-01

    For a number of microtomography applications X-ray detectors with a spatial resolution of 1 {mu}m are required. This high spatial resolution will influence and degrade other parameters of secondary importance like detective quantum efficiency (DQE), dynamic range, linearity and frame rate. This note summarizes the most important arguments, for and against those detector systems which could be considered. This article discusses the mutual dependencies between the various figures which characterize a detector, and tries to give some ideas on how to proceed in order to improve present technology.

  14. Solid state neutron detector array

    SciTech Connect

    Seidel, J.G.; Ruddy, F.H.; Brandt, C.D.; Dulloo, A.R.; Lott, R.G.; Sirianni, E.; Wilson, R.O.

    1999-08-17

    A neutron detector array is capable of measuring a wide range of neutron fluxes. The array includes multiple semiconductor neutron detectors. Each detector has a semiconductor active region that is resistant to radiation damage. In one embodiment, the array preferably has a relatively small size, making it possible to place the array in confined locations. The ability of the array to detect a wide range of neutron fluxes is highly advantageous for many applications such as detecting neutron flux during start up, ramp up and full power of nuclear reactors. 7 figs.

  15. Superconducting thermal neutron detectors

    NASA Astrophysics Data System (ADS)

    Merlo, V.; Pietropaolo, A.; Celentano, G.; Cirillo, M.; Lucci, M.; Ottaviani, I.; Salvato, M.; Scherillo, A.; Schooneveld, E. M.; Vannozzi, A.

    2016-09-01

    A neutron detection concept is presented that is based on superconductive niobium nitride (NbN) strips coated by a boron (B) layer. The working principle is well described by a hot spot mechanism: upon the occurrence of the nuclear reactions n + 10B → α + 7Li + 2.8 MeV, the energy released by the secondary particles into the strip induces a superconducting-normal state transition. The latter is recognized as a voltage signal which is the evidence of the incident neutron. The above described detection principle has been experimentally assessed and verified by irradiating the samples with a pulsed neutron beam at the ISIS spallation neutron source (UK). It is found that the boron coated superconducting strips, kept at a temperature T below 11K and current-biased below the critical current IC, are driven into the normal state upon thermal neutron irradiation. Measurements on the counting rate of the device are presented and the basic physical features of the detector are discussed and compared to those of a borated Nb superconducting strip.

  16. Liquid Hydrogen: Target, Detector

    SciTech Connect

    Mulholland, G.T.; Harigel, G.G.

    2004-06-23

    In 1952 D. Glaser demonstrated that a radioactive source's radiation could boil 135 deg. C superheated-diethyl ether in a 3-mm O glass vessel and recorded bubble track growth on high-speed film in a 2-cm3 chamber. This Bubble Chamber (BC) promised improved particle track time and spatial resolution and cycling rate. Hildebrand and Nagle, U of Chicago, reported Liquid Hydrogen minimum ionizing particle boiling in August 1953. John Wood created the 3.7-cm O Liquid Hydrogen BC at LBL in January 1954. By 1959 the Lawrence Berkley Laboratory (LBL) Alvarez group's '72-inch' BC had tracks in liquid hydrogen. Within 10 years bubble chamber volumes increased by a factor of a million and spread to every laboratory with a substantial high-energy physics program. The BC, particle accelerators and special separated particle beams created a new era of High Energy Physics (HEP) experimentation. The BC became the largest most complex cryogenic installation at the world's HEP laboratories for decades. The invention and worldwide development, deployment and characteristics of these cryogenic dynamic target/detectors and related hydrogen targets are described.

  17. Optical transcutaneous bilirubin detector

    DOEpatents

    Kronberg, J.W.

    1993-11-09

    A transcutaneous bilirubin detector is designed comprising a source of light having spectral components absorbable and not absorbable by bilirubin, a handle assembly, electronic circuitry and a fiber optic bundle connecting the assembly to the light source and circuitry. Inside the assembly is a prism that receives the light from one end of the fiber optic bundle and directs it onto the skin and directs the reflected light back into the bundle. The other end of the bundle is trifucated, with one end going to the light source and the other two ends going to circuitry that determines how much light of each kind has been reflected. A relatively greater amount absorbed by the skin from the portion of the spectrum absorbable by bilirubin may indicate the presence of the illness. Preferably, two measurements are made, one on the kneecap and one on the forehead, and compared to determine the presence of bilirubin. To reduce the impact of light absorption by hemoglobin in the blood carried by the skin, pressure is applied with a plunger and spring in the handle assembly, the pressure limited by points of a button slidably carried in the assembly that are perceived by touch when the pressure applied is sufficient. 6 figures.

  18. Microwave hematoma detector

    DOEpatents

    Haddad, Waleed S.; Trebes, James E.; Matthews, Dennis L.

    2001-01-01

    The Microwave Hematoma Detector is a non-invasive device designed to detect and localize blood pooling and clots near the outer surface of the body. While being geared towards finding sub-dural and epi-dural hematomas, the device can be used to detect blood pooling anywhere near the surface of the body. Modified versions of the device can also detect pneumothorax, organ hemorrhage, atherosclerotic plaque in the carotid arteries, evaluate perfusion (blood flow) at or near the body surface, body tissue damage at or near the surface (especially for burn assessment) and be used in a number of NDE applications. The device is based on low power pulsed microwave technology combined with a specialized antenna, signal processing/recognition algorithms and a disposable cap worn by the patient which will facilitate accurate mapping of the brain and proper function of the instrument. The invention may be used for rapid, non-invasive detection of sub-dural or epi-dural hematoma in human or animal patients, detection of hemorrhage within approximately 5 cm of the outer surface anywhere on a patient's body.

  19. Triple Coincidence Radioxenon Detector

    SciTech Connect

    McIntyre, Justin I.; Aalseth, Craig E.; Bowyer, Ted W.; Hayes, James C.; Heimbigner, Tom R.; Morris, Scott J.; Reeder, Paul L.

    2004-09-22

    The Automated Radioxenon Sampler/Analyzer (ARSA) built by Pacific Northwest National Laboratory (PNNL) is on e of the world’s most sensitive systems for monitoring the four radioxenon isotopes 133Xe, 133mXE, 131mXe and 135Xe. However, due to size, weight and power specifications appropriate to meet treaty-monitoring requirements; the ARSA is unsuitable for rapid deployment using modest transportation means. To transition this technology to a portable unit can be easily and rapidly deployed can be achieved by significant reductions in size, weight and power consumption if concentration were not required. As part of an exploratory effort to reduce both the size of the air sample and the gas processing requirement PNNL has developed an experimental nuclear detector to test and qualify the use of triple coincidence signatures (beta, conversion electron, x-ray) from two of the radioxenon isotopes (135Xe and 133Xe) as well as the more traditional beta-gamma coincidence signatures used by the ARSA system. The additional coincidence requirement allows for reduced passive shielding, and makes it possible for unambiguous detection of 133Xe and 153Xe in the presence of high 222Rn backgrounds. This paper will discuss the experimental setup and the results obtained for a 133Xe sample with and without 222Rn as an interference signature.

  20. Optical transcutaneous bilirubin detector

    DOEpatents

    Kronberg, James W.

    1993-01-01

    A transcutaneous bilirubin detector comprising a source of light having spectral components absorbable and not absorbable by bilirubin, a handle assembly, electronic circuitry and a fiber optic bundle connecting the assembly to the light source and circuitry. Inside the assembly is a prism that receives the light from one end of the fiber optic bundle and directs it onto the skin and directs the reflected light back into the bundle. The other end of the bundle is trifucated, with one end going to the light source and the other two ends going to circuitry that determines how much light of each kind has been reflected. A relatively greater amount absorbed by the skin from the portion of the spectrum absorbable by bilirubin may indicate the presence of the illness. Preferably, two measurements are made, one on the kneecap and one on the forehead, and compared to determine the presence of bilirubin. To reduce the impact of light absorption by hemoglobin in the blood carried by the skin, pressure is applied with a plunger and spring in the handle assembly, the pressure limited by points of a button slidably carried in the assembly that are perceived by touch when the pressure applied is sufficient.

  1. Optical transcutaneous bilirubin detector

    DOEpatents

    Kronberg, J.W.

    1991-03-04

    This invention consists of a transcutaneous bilirubin detector comprising a source of light having spectral components absorbable and not absorbable by bilirubin, a handle assembly, electronic circuitry and a fiber optic bundle connecting the assembly to the light source and circuitry. Inside the assembly is a prism that receives the light from one end of the fiber optic bundle and directs it onto the skin and directs the reflected light back into the bundle. The other end of the bundle is trifucated, with one end going to the light source and the other two ends going to circuitry that determines how much light of each kind has been reflected. A relatively greater amount absorbed by the skin from the portion of the spectrum absorbable by bilirubin may indicate the presence of the illness. Preferably, two measurements are made, one on the kneecap and one on the forehead, and compared to determine the presence of bilirubin. To reduce the impact of light absorption by hemoglobin in the blood carried by the skin, pressure is applied with a plunger and spring in the handle assembly, the pressure limited by points of a button slidably carried in the assembly that are perceived by touch when the pressure applied is sufficient.

  2. Optical Flameout Detector

    NASA Technical Reports Server (NTRS)

    Borg, Stephen E. (Inventor); West, James W. (Inventor); Lawrence, Robert M. (Inventor); Harper, Samuel E., Jr. (Inventor); Alderfer, David W. (Inventor)

    1998-01-01

    A device has been developed which monitors the presence of a flame within a combustion chamber. The optical flameout detection system responds to gross changes in combustor light intensity which is monitored in two spectral bands. A photomultiplier tube makes optical measurements in the ultraviolet portion of the spectrum and a silicon photodiode covers the visible region. The detectors, located outside the combustion chamber, receive the light energy radiated from the combustion process through fiber optic probes designed to operate in a high pressure environment. The optical fibers are aimed diagonally through the center of the injector at the combustion chamber wall downstream of the injector. The probe observes events occurring within a narrow conical-shaped field of view so that the system can quickly detect longitudinal movement of the flame front away from the injector. If a change in intensity of the flame is detected, the fuel supply to the combustion chamber is shut off limiting the amount of unburned fuel in the combustion chamber which could reignite.

  3. A solenoid failure detection system for cold gas attitude control jet valves

    NASA Technical Reports Server (NTRS)

    Johnston, P. A.

    1970-01-01

    The development of a solenoid valve failure detection system is described. The technique requires the addition of a radioactive gas to the propellant of a cold gas jet attitude control system. Solenoid failure is detected with an avalanche radiation detector located in the jet nozzle which senses the radiation emitted by the leaking radioactive gas. Measurements of carbon monoxide leakage rates through a Mariner type solenoid valve are presented as a function of gas activity and detector configuration. A cylindrical avalanche detector with a factor of 40 improvement in leak sensitivity is proposed for flight systems because it allows the quantity of radioactive gas that must be added to the propellant to be reduced to a practical level.

  4. Component failure data handbook

    SciTech Connect

    Gentillon, C.D.

    1991-04-01

    This report presents generic component failure rates that are used in reliability and risk studies of commercial nuclear power plants. The rates are computed using plant-specific data from published probabilistic risk assessments supplemented by selected other sources. Each data source is described. For rates with four or more separate estimates among the sources, plots show the data that are combined. The method for combining data from different sources is presented. The resulting aggregated rates are listed with upper bounds that reflect the variability observed in each rate across the nuclear power plant industry. Thus, the rates are generic. Both per hour and per demand rates are included. They may be used for screening in risk assessments or for forming distributions to be updated with plant-specific data.

  5. Peripheral circulatory failure.

    PubMed

    Lodha, Rakesh; Kapoor, Vishal

    2003-02-01

    Shock is a syndrome arising from any of several initiating causes, resulting in inadequate tissue perfusion. Untreated shock due to any cause can lead to irreversible cellular damage. Early diagnosis and intervention are, therefore, key to improved outcomes. In children, hypotension is not a sensitive marker for diagnosing peripheral circulatory failure. A detailed evaluation to assess perfusion particularly estimating capillary refill time and end organ perfusion is required. Septic shock is a complex condition with varying contribution of hypovolemia, cardiac dysfunction and distributive shock. Aggressive fluid therapy in the early stages is essential to recovery. Understanding the pathophysiology will help in judicious use of vasoactive drugs. Newer modalities of treatment for severe sepsis and septic shock still need evaluation in children.

  6. Iridium: failures & successes

    NASA Astrophysics Data System (ADS)

    Christensen, CarissaBryce; Beard, Suzette

    2001-03-01

    This paper will provide an overview of the Iridium business venture in terms of the challenges faced, the successes achieved, and the causes of the ultimate failure of the venture — bankruptcy and system de-orbit. The paper will address technical, business, and policy issues. The intent of the paper is to provide a balanced and accurate overview of the Iridium experience, to aid future decision-making by policy makers, the business community, and technical experts. Key topics will include the history of the program, the objectives and decision-making of Motorola, the market research and analysis conducted, partnering strategies and their impact, consumer equipment availability, and technical issues — target performance, performance achieved, technical accomplishments, and expected and unexpected technical challenges. The paper will use as sources trade media and business articles on the Iridium program, technical papers and conference presentations, Wall Street analyst's reports, and, where possible, interviews with participants and close observers.

  7. Mud pump failure analysis

    SciTech Connect

    Lewis, E.C. II

    1981-10-01

    Extrusion, the primary cause of piston failure, is the degradation of a seal caused by the seal material moving into the interface between the two parts being sealed. It is shown that operational dynamics of the mud piston lead to an aggravated extrusion condition. As both the liner wall and the piston OD lose material, the clearance gap between liner and piston increases. This gap provides the piston seal a space to move into when pressurized. This movement, called extrusion, is undesirable because the piston rubber is then subjected to abnormal stresses which it cannot tolerate. As the piston moves forward, this extruded material is gradually nibbled away. Extrusion and nibble action continue on each stroke of the pump as additional rubber moves away from the high-pressure side of the piston toward the low-pressure side. A discussion is presented of extrusion rates and seal leakage.

  8. Metabolic mechanisms in heart failure.

    PubMed

    Ashrafian, Houman; Frenneaux, Michael P; Opie, Lionel H

    2007-07-24

    Although neurohumoral antagonism has successfully reduced heart failure morbidity and mortality, the residual disability and death rate remains unacceptably high. Though abnormalities of myocardial metabolism are associated with heart failure, recent data suggest that heart failure may itself promote metabolic changes such as insulin resistance, in part through neurohumoral activation. A detrimental self-perpetuating cycle (heart failure --> altered metabolism --> heart failure) that promotes the progression of heart failure may thus be postulated. Accordingly, we review the cellular mechanisms and pathophysiology of altered metabolism and insulin resistance in heart failure. It is hypothesized that the ensuing detrimental myocardial energetic perturbations result from neurohumoral activation, increased adverse free fatty acid metabolism, decreased protective glucose metabolism, and in some cases insulin resistance. The result is depletion of myocardial ATP, phosphocreatine, and creatine kinase with decreased efficiency of mechanical work. On the basis of the mechanisms outlined, appropriate therapies to mitigate aberrant metabolism include intense neurohumoral antagonism, limitation of diuretics, correction of hypokalemia, exercise, and diet. We also discuss more novel mechanistic-based therapies to ameliorate metabolism and insulin resistance in heart failure. For example, metabolic modulators may optimize myocardial substrate utilization to improve cardiac function and exercise performance beyond standard care. The ultimate success of metabolic-based therapy will be manifest by its capacity further to lessen the residual mortality in heart failure.

  9. Heart Failure in South America

    PubMed Central

    Bocchi, Edimar Alcides

    2013-01-01

    Continued assessment of temporal trends in mortality and epidemiology of specific heart failure in South America is needed to provide a scientific basis for rational allocation of the limited health care resources, and strategies to reduce risk and predict the future burden of heart failure. The epidemiology of heart failure in South America was reviewed. Heart failure is the main cause of hospitalization based on available data from approximately 50% of the South American population. The main etiologies of heart failure are ischemic, idiopathic dilated cardiomyopathy, valvular, hypertensive and chagasic etiologies. In endemic areas, Chagas heart disease may be responsible by 41% of the HF cases. Also, heart failure presents high mortality especially in patients with Chagas etiology. Heart failure and etiologies associated with heart failure may be responsible for 6.3% of causes of deaths. Rheumatic fever is the leading cause of valvular heart disease. However, a tendency to reduction of HF mortality due to Chagas heart disease from 1985 to 2006, and reduction in mortality due to HF from 1999 to 2005 were observed in selected states in Brazil. The findings have important public health implications because the allocation of health care resources, and strategies to reduce risk of heart failure should also consider the control of neglected Chagas disease and rheumatic fever in South American countries. PMID:23597301

  10. Strategies of learning from failure.

    PubMed

    Edmondson, Amy C

    2011-04-01

    Many executives believe that all failure is bad (although it usually provides Lessons) and that Learning from it is pretty straightforward. The author, a professor at Harvard Business School, thinks both beliefs are misguided. In organizational life, she says, some failures are inevitable and some are even good. And successful learning from failure is not simple: It requires context-specific strategies. But first leaders must understand how the blame game gets in the way and work to create an organizational culture in which employees feel safe admitting or reporting on failure. Failures fall into three categories: preventable ones in predictable operations, which usually involve deviations from spec; unavoidable ones in complex systems, which may arise from unique combinations of needs, people, and problems; and intelligent ones at the frontier, where "good" failures occur quickly and on a small scale, providing the most valuable information. Strong leadership can build a learning culture-one in which failures large and small are consistently reported and deeply analyzed, and opportunities to experiment are proactively sought. Executives commonly and understandably worry that taking a sympathetic stance toward failure will create an "anything goes" work environment. They should instead recognize that failure is inevitable in today's complex work organizations.

  11. Belle II Silicon Vertex Detector

    NASA Astrophysics Data System (ADS)

    Dutta, D.; Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, Ti.; Baroncelli, To.; Basith, A. K.; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Bulla, L.; Caria, G.; Casarosa, G.; Ceccanti, M.; Červenkov, D.; Chendvankar, S. R.; Dash, N.; De Pietro, G.; Divekar, S. T.; Doležal, Z.; Forti, F.; Friedl, M.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C.; Kandra, J.; Kambara, N.; Kang, K. H.; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M.; Kumar, R.; Kun, W.; Kvasnička, P.; La Licata, C.; Lanceri, L.; Lettenbicher, J.; Libby, J.; Lueck, T.; Maki, M.; Mammini, P.; Mayekar, S. N.; Mohanty, G. B.; Mohanty, S.; Morii, T.; Nakamura, K. R.; Natkaniec, Z.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rashevskaya, I.; Rao, K. K.; Rizzo, G.; Resmi, P. K.; Rozanska, M.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Suzuki, J.; Tanaka, S.; Taylor, G. N.; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Vitale, L.; Watanuki, S.; Watanabe, M.; Watson, I. J.; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.; Zani, L.

    2017-02-01

    The Belle II experiment at the SuperKEKB asymmetric energy e+e‑ collider in KEK, Japan will operate at an instantaneous luminosity 40 times larger than that of its predecessor, Belle. It is built with an aim of collecting a huge amount of data (50 ab‑1 by 2025) for precise CP violation measurements and new physics search. Thus, we need an accurate vertex determination and reconstruction of low momentum tracks which will be achieved with the help of vertex detector (VXD). The Belle II VXD consists of two layers of DEPFET pixels (`Pixel Detector') and four layers of double-sided silicon microstrip sensors (`Silicon Vertex Detector'), assembled over carbon fibre ribs. In this paper, we discuss about the Belle II Silicon Vertex Detector, especially its design and key features; we also present its module (`ladder') assembly and testing procedures.

  12. Modulated voltage metastable ionization detector

    NASA Technical Reports Server (NTRS)

    Carle, G. C.; Kojiro, D. R.; Humphrey, D. E. (Inventor)

    1985-01-01

    The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration of the constituent and a representative amplitude is applied to another input of said strip chart recorder.

  13. Evaluation of bismuth germanate detectors

    SciTech Connect

    Swinth, K.L.; Eschbach, P.A.

    1993-12-01

    During International Atomic Energy Agency (IAEA) safeguards inspections, one of the activities is the verification of materials in the inventory through quantitative or qualitative measurements. Performance of these measurements requires an array of sophisticated detectors, electronics, shields, and stands. This requires the transport and handling of delicate systems that are both heavy and bulky. The increasing sophistication and miniaturization of electronic and computer systems have led to progressive reductions in both the weight and the bulk of such electronics. However, to take full advantage of these improvements, similar reductions must also occur in the size and weight of the detectors. The purpose of this study was to explore the usefulness of one type of new detector, the bismuth germinate (BGO) scintillator. The purpose was to test detectors for their performance at high (fission products) and low ({sup 235}U) photon energies. Information is also provided on other scintillators, including those using photodiode-coupled cesium iodide and germanium orthosilicate.

  14. Simple dynamic electromagnetic radiation detector

    NASA Technical Reports Server (NTRS)

    Been, J. F.

    1972-01-01

    Detector monitors gamma dose rate at particular position in a radiation facility where a mixed neutron-gamma environment exists, thus determining reactor power level changes. Device also maps gamma intensity profile across a neutron-gamma beam.

  15. Encapsulating X-Ray Detectors

    NASA Technical Reports Server (NTRS)

    Conley, Joseph M.; Bradley, James G.

    1987-01-01

    Vapor-deposited polymer shields crystals from environment while allowing X rays to pass. Polymer coating transparental to X rays applied to mercuric iodide detector in partial vacuum. Coating protects crystal from sublimation, chemical attack, and electrical degradation.

  16. Signal processing for semiconductor detectors

    SciTech Connect

    Goulding, F.S.; Landis, D.A.

    1982-02-01

    A balanced perspective is provided on the processing of signals produced by semiconductor detectors. The general problems of pulse shaping to optimize resolution with constraints imposed by noise, counting rate and rise time fluctuations are discussed.

  17. All-electric gas detector

    NASA Technical Reports Server (NTRS)

    Margolis, J. S.

    1979-01-01

    Modified optoacoustic gas detector identifies gases by measuring pressure-induced voltage charge in electric signals. Can detect water vapor, atmospheric fluorocarbons, or certain nitrous or nitric compounds that indicate presence of explosives.

  18. Detector Fundamentals for Reachback Analysts

    SciTech Connect

    Karpius, Peter Joseph; Myers, Steven Charles

    2016-08-03

    This presentation is a part of the DHS LSS spectroscopy course and provides an overview of the following concepts: detector system components, intrinsic and absolute efficiency, resolution and linearity, and operational issues and limits.

  19. Public Choice, Market Failure, and Government Failure in Principles Textbooks

    ERIC Educational Resources Information Center

    Fike, Rosemarie; Gwartney, James

    2015-01-01

    Public choice uses the tools of economics to analyze how the political process allocates resources and impacts economic activity. In this study, the authors examine twenty-three principles texts regarding coverage of public choice, market failure, and government failure. Approximately half the texts provide coverage of public choice and recognize…

  20. Gated high speed optical detector

    NASA Technical Reports Server (NTRS)

    Green, S. I.; Carson, L. M.; Neal, G. W.

    1973-01-01

    The design, fabrication, and test of two gated, high speed optical detectors for use in high speed digital laser communication links are discussed. The optical detectors used a dynamic crossed field photomultiplier and electronics including dc bias and RF drive circuits, automatic remote synchronization circuits, automatic gain control circuits, and threshold detection circuits. The equipment is used to detect binary encoded signals from a mode locked neodynium laser.

  1. The atmosphere as particle detector

    NASA Technical Reports Server (NTRS)

    Stanev, Todor

    1990-01-01

    The possibility of using an inflatable, gas-filled balloon as a TeV gamma-ray detector on the moon is considered. By taking an atmosphere of Xenon gas there, or by extracting it on the moon, a layman's detector design is presented. In spite of its shortcomings, the exercise illustrates several of the novel features offered by particle physics on the moon.

  2. STAR Vertex Detector Upgrade Development

    SciTech Connect

    Greiner, Leo C.; Matis, Howard S.; Stezelberger, Thorsten; Vu,Chinh Q.; Wieman, Howard; Szelezniak, Michal; Sun, Xiangming

    2008-01-28

    We report on the development and prototyping efforts undertaken with the goal of producing a micro-vertex detector for the STAR experiment at the RHIC accelerator at BNL. We present the basic detector requirements and show a sensor development path, conceptual mechanical design candidates and readout architecture. Prototyping and beam test results with current generation MimoSTAR-2 sensors and a readout system featuring FPGA based on-the-fly hit finding and data sparsification are also presented.

  3. Living Membranes as Environmental Detectors

    DTIC Science & Technology

    2016-02-19

    addition to the core results, we have explored important aspects of the system, including loading capacity, long-term stability, detection capacity, and...Oct-2011 30-Sep-2015 Approved for Public Release; Distribution Unlimited Final Report: Living Membranes as Environmental Detectors The views, opinions...Report: Living Membranes as Environmental Detectors Report Title The work conducted over the course of this program has made significant progress

  4. Neutron detectors comprising boron powder

    DOEpatents

    Wang, Zhehui; Morris, Christopher; Bacon, Jeffrey Darnell; Makela, Mark F; Spaulding, Randy Jay

    2013-05-21

    High-efficiency neutron detector substrate assemblies comprising a first conductive substrate, wherein a first side of the substrate is in direct contact with a first layer of a powder material comprising .sup.10boron, .sup.10boron carbide or combinations thereof, and wherein a conductive material is in proximity to the first layer of powder material; and processes of making said neutron detector substrate assemblies.

  5. Improvement in Ge Detector Cooling

    DTIC Science & Technology

    2008-09-01

    lifetime and integrity, improve performance, and resolve the need to procure and handle liquid nitrogen (LN2). Both cryocoolers offer advantages over...place, the 22-liter reservoir of LN2 provides up to 7 days of cooling to the detector with no risk of a partial thermal cycle or warm -up. The detector... warmed for repairs. Moreover, the interchangeability of dipsticks and Cryo-Cycle™ coolers allows independent replacement of either of the two most

  6. Long range alpha particle detector

    DOEpatents

    MacArthur, D.W.; Wolf, M.A.; McAtee, J.L.; Unruh, W.P.; Cucchiara, A.L.; Huchton, R.L.

    1993-02-02

    An alpha particle detector capable of detecting alpha radiation from distant sources. In one embodiment, a high voltage is generated in a first electrically conductive mesh while a fan draws air containing air molecules ionized by alpha particles through an air passage and across a second electrically conductive mesh. The current in the second electrically conductive mesh can be detected and used for measurement or alarm. The detector can be used for area, personnel and equipment monitoring.

  7. Modern Detectors for Astroparticle Physics

    SciTech Connect

    Adriani, Oscar

    2005-10-12

    This paper focus on the necessary requirements for a modern astroparticle physics detector based either on stratospheric balloons, either on satellite. The main technical solutions used to build a reliable detector are described. Finally, the most relevant experiments that have been developed with the INFN contribution and that will be ready in the near future (both for {gamma} and charged cosmic rays detection) are described.

  8. Directional detector of gamma rays

    DOEpatents

    Cox, Samson A.; Levert, Francis E.

    1979-01-01

    A directional detector of gamma rays comprises a strip of an electrical cuctor of high atomic number backed with a strip of a second electrical conductor of low atomic number. These elements are enclosed within an electrical conductor that establishes an electrical ground, maintains a vacuum enclosure and screens out low-energy gamma rays. The detector exhibits a directional sensitivity marked by an increased output in the favored direction by a factor of ten over the output in the unfavored direction.

  9. Coal-shale interface detector

    NASA Technical Reports Server (NTRS)

    Reid, H., Jr. (Inventor)

    1980-01-01

    A coal-shale interface detector for use with coal cutting equipment is described. The detector consists of a reciprocating hammer with an accelerometer to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. Additionally, a pair of reflectometers simultaneously view the same surface, and the outputs from the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  10. Radiation Hazard Detector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    NASA technology has made commercially available a new, inexpensive, conveniently-carried device for protection, of people exposed to potentially dangerous levels of microwave radiation. Microwaves are radio emissions of extremely high frequency. They can be hazardous but the degree of hazard is not yet well understood. Generally, it is believed that low intensity radiation of short duration is not harmful but that exposure to high levels can induce deep internal burns, affecting the circulatory and nervous systems, and particularly the eyes. The Department of Labor's Occupational Safety and Health Administration (OSHA) has established an allowable safe threshold of exposure. However, people working near high intensity sources of microwave energy-for example, radar antennas and television transmitters-may be unknowingly exposed to radiation levels beyond the safe limit. This poses not only a personal safety problem but also a problem for employers in terms of productivity loss, workman's compensation claims and possible liability litigation. Earlier-developed monitoring devices which warn personnel of dangerous radiation levels have their shortcomings. They can be cumbersome and awkward to use while working. They also require continual visual monitoring to determine if a person is in a dangerous area of radiation, and they are relatively expensive, another deterrent to their widespread adoption. In response to the need for a cheaper and more effective warning system, Jet Propulsion Laboratory developed, under NASA auspices, a new, battery-powered Microwave Radiation Hazard Detector. To bring the product to the commercial market, California Institute Research Foundation, the patent holder, granted an exclusive license to Cicoil Corporation, Chatsworth, California, an electronic components manufacturer.

  11. Detecting link failures in complex network processes using remote monitoring

    NASA Astrophysics Data System (ADS)

    Dhal, R.; Abad Torres, J.; Roy, S.

    2015-11-01

    We study whether local structural changes in a complex network can be distinguished from passive remote time-course measurements of the network's dynamics. Specifically the detection of link failures in a network synchronization process from noisy measurements at a single network component is considered. By phrasing the detection task as a Maximum A Posteriori Probability hypothesis testing problem, we are able to obtain conditions under which the detection is (1) improved over the a priori and (2) asymptotically perfect, in terms of the network spectrum and graph. We find that, in the case where the detector has knowledge of the network's state, perfect detection is possible under general connectivity conditions regardless of the measurement location. When the detector does not have state knowledge, a remote signature permits improved but not perfect detection, under the same connectivity conditions. At its essence, detectability is achieved because of the close connection between a network's topology, its eigenvalues and local response characteristics.

  12. New class of neutron detectors

    SciTech Connect

    Czirr, J.B.

    1997-09-01

    An optimized neutron scattering instrument design must include all significant components, including the detector. For example, useful beam intensity is limited by detector dead time; detector pixel size determines the optimum beam diameter, sample size, and sample to detector distance; and detector efficiency vs. wavelength determines the available energy range. As an example of the next generation of detectors that could affect overall instrumentation design, we will describe a new scintillator material that is potentially superior to currently available scintillators. We have grown and tested several small, single crystal scintillators based upon the general class of cerium-activated lithium lanthanide borates. The outstanding characteristic of these materials is the high scintillation efficiency-as much as five times that of Li-glass scintillators. This increase in light output permits the practical use of the exothermic B (n, alpha) reaction for low energy neutron detection. This reaction provides a four-fold increase in capture cross section relative to the Li (n, alpha) reaction, and the intriguing possibility of demanding a charged-particle/gamma ray coincidence to reduce background detection rates. These new materials will be useful in the thermal and epithermal energy ran at reactors and pulsed neutron sources.

  13. Four-Channel Threshold Detector With Optical Isolation

    DTIC Science & Technology

    2009-02-01

    Metal Film Resistor 1 1 N4733 5.1 V Zenor Diode 2 2N3904w General Purpose NPN Transistor 2 OMISS2 12D 12V DPDT Relay 1 Table C-2. The two...are controlled from the relay board’s control transistor (Q2). 2. Theory of Operation The threshold detector consists of two different electronics...the comparators indicates either a failure or an exceeded threshold. The complementary metal oxide semiconducting field-effect transistor (CMOS) AND

  14. 14 CFR 125.173 - Fire detectors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fire detectors. 125.173 Section 125.173....173 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability... subjected. Fire detectors must be unaffected by exposure to fumes, oil, water, or other fluids that may...

  15. 14 CFR 125.173 - Fire detectors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Fire detectors. 125.173 Section 125.173....173 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability... subjected. Fire detectors must be unaffected by exposure to fumes, oil, water, or other fluids that may...

  16. 14 CFR 125.173 - Fire detectors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Fire detectors. 125.173 Section 125.173....173 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability... subjected. Fire detectors must be unaffected by exposure to fumes, oil, water, or other fluids that may...

  17. 14 CFR 125.173 - Fire detectors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fire detectors. 125.173 Section 125.173....173 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability... subjected. Fire detectors must be unaffected by exposure to fumes, oil, water, or other fluids that may...

  18. 14 CFR 125.173 - Fire detectors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire detectors. 125.173 Section 125.173....173 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability... subjected. Fire detectors must be unaffected by exposure to fumes, oil, water, or other fluids that may...

  19. Performance of ultra-fast silicon detectors

    NASA Astrophysics Data System (ADS)

    Cartiglia, N.; Baselga, M.; Dellacasa, G.; Ely, S.; Fadeyev, V.; Galloway, Z.; Garbolino, S.; Marchetto, F.; Martoiu, S.; Mazza, G.; Ngo, J.; Obertino, M.; Parker, C.; Rivetti, A.; Shumacher, D.; F-W Sadrozinski, H.; Seiden, A.; Zatserklyaniy, A.

    2014-02-01

    The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche Detectors, and in particular we demonstrate the possibility of obtaining ultra-fast silicon detector with time resolution of less than 20 picosecond.

  20. Failure criteria for viscoelastic materials

    NASA Technical Reports Server (NTRS)

    Knauss, W. G.

    1974-01-01

    Research projects concerned with developing a theory of fracture of materials are discussed. The effects of the geometry of the structure and the loads acting on the structure as they influence the failure process are analyzed. The effects of the viscoelastic deformation characteristics of the bulk elastomer on failure behavior are examined. Additional material parameters which control the fracture process are identified.

  1. Failure to Manage Constant Change

    ERIC Educational Resources Information Center

    McDonald, Ann

    2010-01-01

    This study examines patterns of system failure (communication, typographic, material, economic, maintenance) and the resulting workarounds in signs that are intended to communicate frequently changing information in the built environment. The observed failures and workarounds in the communication of ephemeral data and the accompanying narratives…

  2. Failure Engineered Heavy Metal Penetrators

    DTIC Science & Technology

    1992-12-01

    ARMY RESEARCH LABORATORY Failure Engineered Heavy Metal Penetrators, Phase I, SBIR ARL-CR-5· R. Cavalieri, W. Tiarn, and D. Nicholson prepared...REPORT DATE S. REPORT TYPE AND DATES COVERED December 1992 Final Report-1/1/92 - 7/31/92 4. TITLE AND SUBTITLE FAILURE ENGINEERED HEAVY METAL PENETRATORS

  3. Failure detection system risk reduction assessment

    NASA Technical Reports Server (NTRS)

    Aguilar, Robert B. (Inventor); Huang, Zhaofeng (Inventor)

    2012-01-01

    A process includes determining a probability of a failure mode of a system being analyzed reaching a failure limit as a function of time to failure limit, determining a probability of a mitigation of the failure mode as a function of a time to failure limit, and quantifying a risk reduction based on the probability of the failure mode reaching the failure limit and the probability of the mitigation.

  4. Advanced Space Radiation Detector Technology Development

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.

    2013-01-01

    The advanced space radiation detector development team at NASA Glenn Research Center (GRC) has the goal of developing unique, more compact radiation detectors that provide improved real-time data on space radiation. The team has performed studies of different detector designs using a variety of combinations of solid-state detectors, which allow higher sensitivity to radiation in a smaller package and operate at lower voltage than traditional detectors. Integration of multiple solid-state detectors will result in an improved detector system in comparison to existing state-of-the-art (SOA) instruments for the detection and monitoring of the space radiation field for deep space and aerospace applications.

  5. Advanced Space Radiation Detector Technology Development

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.

    2013-01-01

    The advanced space radiation detector development team at NASA Glenn Research Center (GRC) has the goal of developing unique, more compact radiation detectors that provide improved real-time data on space radiation. The team has performed studies of different detector designs using a variety of combinations of solid-state detectors, which allow higher sensitivity to radiation in a smaller package and operate at lower voltage than traditional detectors. Integration of multiple solid-state detectors will result in an improved detector system in comparison to existing state-of-the-art instruments for the detection and monitoring of the space radiation field for deep space and aerospace applications.

  6. Advanced Space Radiation Detector Technology Development

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Wrbanek, Susan Y.; Fralick, Gustave C.

    2013-01-01

    The advanced space radiation detector development team at the NASA Glenn Research Center (GRC) has the goal of developing unique, more compact radiation detectors that provide improved real-time data on space radiation. The team has performed studies of different detector designs using a variety of combinations of solid-state detectors, which allow higher sensitivity to radiation in a smaller package and operate at lower voltage than traditional detectors. Integration of multiple solid-state detectors will result in an improved detector system in comparison to existing state-of-the-art instruments for the detection and monitoring of the space radiation field for deep space and aerospace applications.

  7. A Satellite Borne Cadmium Sulfide Total Corpuscular Energy Detector

    NASA Technical Reports Server (NTRS)

    Freeman, John W.

    1961-01-01

    transmission of data. A pair of such detectors was flown as part of the s-46 satellite payload on March 23, 1960, but due to vehicular failure an orbit was not achieved and the operation of the CdS detectors was observed for only, six minutes of flight.

  8. Failure to recall.

    PubMed

    Laming, Donald

    2009-01-01

    Mathematical analysis shows that if the pattern of rehearsal in free-recall experiments (of necessity, the pattern observed when participants rehearse aloud) be continued without any further interruption by stimuli (as happens during recall), it terminates with the retrieval of the same 1 word over and over again. Such a terminal state is commonly reached before some of the words in the list have been retrieved even once; those words are not recalled. The 1 minute frequently allowed for recall in free-recall experiments is ample time for retrieval to seize up in this way. The author proposes a model that represents the essential features of the pattern of rehearsal; validates that model by reference to the overt rehearsal data from B. B. Murdock, Jr., and J. Metcalfe (1978) and the recall data from B. B. Murdock, Jr., and R. Okada (1970); demonstrates the long-term properties of continued sequences of retrievals and, also, a fundamental relation linking recall to the total time of presentation; and, finally, compares failure to recall in free-recall experiments with forgetting in general.

  9. Pharmacotherapy of autonomic failure

    PubMed Central

    Shibao, Cyndya; Okamoto, Luis; Biaggioni, Italo

    2012-01-01

    The clinical picture of autonomic failure is characterized by severe and disabling orthostatic hypotension. These disorders can develop as a result of damage of central neural pathways or peripheral autonomic nerves, caused either by a primary autonomic neurodegenerative disorder or secondary to systemic illness. Treatment should be focused on decreasing presyncopal symptoms instead of achieving blood pressure goals. Non-pharmacologic strategies such as physical counter-maneuvers, dietary changes (i.e. high salt diet, rapid water drinking or compression garments) are the first line therapy. Affected patients should be screened for co-morbid conditions such as post-prandial hypotension and supine hypertension that can worsen orthostatic hypotension if not treated. If symptoms are not controlled with these conservative measures the next step is to start pharmacological agents; these interventions should be aimed at increasing intravascular volume either by promoting water and salt retention (fludrocortisone) or by increasing red blood cell mass when anemia is present (recombinant erythropoietin). When pressor agents are needed, direct pressor agents (midodrine) or agents that potentiate sympathetic activity (atomoxetine, yohimbine, pyridostigmine) can be used. It is preferable to use short-acting pressor agents that can be taken on as needed basis in preparation for upright activities. PMID:21664375

  10. Rethinking Heart Failure

    PubMed Central

    Fürstenwerth, Hauke

    2012-01-01

    An increasing body of clinical observations and experimental evidence suggests that cardiac dysfunction results from autonomic dysregulation of the contractile output of the heart. Excessive activation of the sympathetic nervous system and a decrease in parasympathetic tone are associated with increased mortality. Elevated levels of circulating catecholamines closely correlate with the severity and poor prognosis in heart failure. Sympathetic over-stimulation causes increased levels of catecholamines, which induce excessive aerobic metabolism leading to excessive cardiac oxygen consumption. Resulting impaired mitochondrial function causes acidosis, which results in reduction in blood flow by impairment of contractility. To the extent that the excessive aerobic metabolism resulting from adrenergic stimulation comes to a halt the energy deficit has to be compensated for by anaerobic metabolism. Glucose and glycogen become the essential nutrients. Beta-adrenergic blockade is used successfully to decrease hyperadrenergic drive. Neurohumoral antagonists block adrenergic over-stimulation but do not provide the heart with fuel for compensatory anaerobic metabolism. The endogenous hormone ouabain reduces catecholamine levels in healthy volunteers, promotes the secretion of insulin, induces release of acetylcholine from synaptosomes and potentiates the stimulation of glucose metabolism by insulin and acetylcholine. Ouabain stimulates glycogen synthesis and increases lactate utilisation by the myocardium. Decades of clinical experience with ouabain confirm the cardioprotective effects of this endogenous hormone. The so far neglected sympatholytic and vagotonic effects of ouabain on myocardial metabolism clearly make a clinical re-evaluation of this endogenous hormone necessary. Clinical studies with ouabain that correspond to current standards are warranted.

  11. Acute liver failure.

    PubMed

    Blackmore, Laura; Bernal, William

    2015-10-01

    Acute liver failure (ALF) is a rare critical illness with high mortality whose successful management requires early recognition and effective initial management. Though it may result from a wide variety of causes, in the UK and much of the developed world most cases result from paracetamol-induced hepatotoxicity, and administration of antidotal N-acetyl cysteine at first recognition is key. Involvement of local critical care services should occur at an early stage for stabilisation, monitoring and supportive care with parallel discussion with specialist liver centres to identify those patients who may benefit from transfer. Prognostic criteria are applied to identify patients for emergency liver transplantation, and candidates for surgery are prioritised on waitlisting schemes. Outcomes now approach that of elective surgery. However, the majority of cases, and particularly those with paracetamol-induced disease, recover with supportive medical care alone. Overall outcomes for patients with ALF have improved dramatically over the last three decades, but mortality remains unacceptable and further advances in care are required.

  12. Semiconductor detectors in nuclear and particle physics

    SciTech Connect

    Rehak, P.; Gatti, E.

    1992-12-31

    Semiconductor detectors for elementary particle physics and nuclear physics in the energy range above 1 GeV are briefly reviewed. In these two fields semiconductor detectors are used mainly for the precise position sensing. In a typical experiment, the position of a fast charged particle crossing a relatively thin semiconductor detector is measured. The position resolution achievable by semiconductor detectors is compared with the resolution achievable by gas filled position sensing detectors. Semiconductor detectors are divided into two groups: Classical semiconductor diode detectors and semiconductor memory detectors. Principles of the signal formation and the signal read-out for both groups of detectors are described. New developments of silicon detectors of both groups are reported.

  13. [Premature ovarian failure: present aspects].

    PubMed

    Vilodre, Luiz Cesar; Moretto, Marcelo; Kohek, Maria Beatriz da Fonte; Spritzer, Poli Mara

    2007-08-01

    Premature ovarian failure occurs in approximately 1:1000 women before 30 years, 1:250 by 35 years and 1:100 by the age of 40. It is characterized by primary or secondary amenorrhea and cannot be considered as definitive because spontaneous conception may occur in 5 to 10% of cases. In 95% of cases, premature ovarian failure is sporadic. The known causes of premature ovarian failure include chromosomal defects, autoimmune diseases, exposure to radiation or chemotherapy, surgical procedures, and certain drugs. Frequently, however, the etiology is not clear and these cases are considered to be idiopathic. Premature ovarian failure is defined by gonadal failure and high serum follicle-stimulating hormone (FSH) levels. Clinical approach includes emotional support, hormonal therapy with estrogens and progesterone or progestogens, infertility treatment, and prevention of osteoporosis and potential cardiovascular risk.

  14. Right side of heart failure.

    PubMed

    Guglin, Maya; Verma, Sameer

    2012-05-01

    The function of the right ventricle (RV) in heart failure (HF) has been mostly ignored until recently. A 2006 report of the National Heart, Lung, and Blood Institute identified a gap between RV research efforts and its clinical importance compared with that of the left ventricle. This recent shift in paradigm is fueled by the prognostic value ascribed to RV failure in HF and morbidity/mortality after myocardial infarction and surgery. In this review, we examine the significance of RV failure in the HF setting, its clinical presentation and pathophysiology, and ways to evaluate RV function using echocardiographic measurements. Furthermore, we discuss the medical management of RV failure including traditional therapies like beta-blockers and newer options like nitric oxide, phosphodiesterase inhibitors, and calcium sensitizers. Mechanical support is also examined. Finally, this review places an emphasis on RV failure in the setting of left ventricular assist devices and heart transplantation.

  15. Medical therapy for spermatogenic failure

    PubMed Central

    Ramasamy, Ranjith; Stahl, Peter J; Schlegel, Peter N

    2012-01-01

    Medical treatment of men with primary spermatogenic failure remains largely ineffective in contrast to those with secondary testicular failure. Treatment has been attempted with a multitude of agents ranging from hormones to nutritional supplements (antioxidants). While some studies have demonstrated benefit to some treatments, no treatments have consistently demonstrated efficacy nor has it been possible to reliably identify patients likely to benefit. Idiopathic spermatogenic failure likely results from multiple discrete defects in sperm production that are as yet unidentified. A better understanding of these defects will yield more effective treatment options and appropriate triage of patients to specific therapeutic regimens. This review focuses on the rationale and current evidence for hormonal and antioxidant therapy in medical treatment of male infertility, spermatogenic failure in particular. Although empiric medical therapy for spermatogenic failure has been largely replaced by assisted reproductive techniques, both treatment modalities could play a role, perhaps as combination therapy. PMID:22179517

  16. Intelligent Design and Intelligent Failure

    NASA Technical Reports Server (NTRS)

    Jerman, Gregory

    2015-01-01

    Good Evening, my name is Greg Jerman and for nearly a quarter century I have been performing failure analysis on NASA's aerospace hardware. During that time I had the distinct privilege of keeping the Space Shuttle flying for two thirds of its history. I have analyzed a wide variety of failed hardware from simple electrical cables to cryogenic fuel tanks to high temperature turbine blades. During this time I have found that for all the time we spend intelligently designing things, we need to be equally intelligent about understanding why things fail. The NASA Flight Director for Apollo 13, Gene Kranz, is best known for the expression "Failure is not an option." However, NASA history is filled with failures both large and small, so it might be more accurate to say failure is inevitable. It is how we react and learn from our failures that makes the difference.

  17. Pure autonomic failure without synucleinopathy.

    PubMed

    Isonaka, Risa; Holmes, Courtney; Cook, Glen A; Sullivan, Patti; Sharabi, Yehonatan; Goldstein, David S

    2017-04-01

    Pure autonomic failure is a rare form of chronic autonomic failure manifesting with neurogenic orthostatic hypotension and evidence of sympathetic noradrenergic denervation unaccompanied by signs of central neurodegeneration. It has been proposed that pure autonomic failure is a Lewy body disease characterized by intra-neuronal deposition of the protein alpha-synuclein in Lewy bodies and neurites. A middle-aged man with previously diagnosed pure autonomic failure experienced a sudden, fatal cardiac arrest. He was autopsied, and tissues were harvested for neurochemical and immunofluorescence studies. Post-mortem microscopic neuropathology showed no Lewy bodies, Lewy neurites, or alpha-synuclein deposition by immunohistochemistry anywhere in the brain. The patient had markedly decreased immunofluorescent tyrosine hydroxylase in sympathetic ganglion tissue without detectable alpha-synuclein even in rare residual nests of tyrosine hydroxylase-containing ganglionic fibers. In pure autonomic failure, sympathetic noradrenergic denervation can occur without concurrent Lewy bodies or alpha-synuclein deposition in the brain or sympathetic ganglion tissue.

  18. STS-3 main parachute failure

    NASA Technical Reports Server (NTRS)

    Runkle, R.; Henson, K.

    1982-01-01

    A failure analysis of the parachute on the Space Transportation System 3 flight's solid rocket booster's is presented. During the reentry phase of the two Solid Rocket Boosters (SRBs), one 115 ft diameter main parachute failed on the right hand SRB (A12). This parachute failure caused the SRB to impact the Ocean at 110 ft/sec in lieu of the expected 3 parachute impact velocity of 88 ft/sec. This higher impact velocity relates directly to more SRB aft skirt and more motor case damage. The cause of the parachute failure, the potential risks of losing an SRB as a result of this failure, and recommendations to ensure that the probability of chute failures of this type in the future will be low are discussed.

  19. Heart Failure in North America

    PubMed Central

    Blair, John E. A; Huffman, Mark; Shah, Sanjiv J

    2013-01-01

    Heart failure is a major health problem that affects patients and healthcare systems worldwide. Within the continent of North America, differences in economic development, genetic susceptibility, cultural practices, and trends in risk factors and treatment all contribute to both inter-continental and within-continent differences in heart failure. The United States and Canada represent industrialized countries with similar culture, geography, and advanced economies and infrastructure. During the epidemiologic transition from rural to industrial in countries such as the United States and Canada, nutritional deficiencies and infectious diseases made way for degenerative diseases such as cardiovascular diseases, cancer, overweight/obesity, and diabetes. This in turn has resulted in an increase in heart failure incidence in these countries, especially as overall life expectancy increases. Mexico, on the other hand, has a less developed economy and infrastructure, and has a wide distribution in the level of urbanization as it becomes more industrialized. Mexico is under a period of epidemiologic transition and the etiology and incidence of heart failure is rapidly changing. Ethnic differences within the populations of the United States and Canada highlight the changing demographics of each country as well as potential disparities in heart failure care. Heart failure with preserved ejection fraction makes up approximately half of all hospital admissions throughout North America; however, important differences in demographics and etiology exist between countries. Similarly, acute heart failure etiology, severity, and management differ between countries in North America. The overall economic burden of heart failure continues to be large and growing worldwide, with each country managing this burden differently. Understanding the inter-and within-continental differences may help improve understanding of the heart failure epidemic, and may aid healthcare systems in delivering

  20. Diamond detector for alpha-particle spectrometry.

    PubMed

    Dueñas, J A; de la Torre Pérez, J; Martín Sánchez, A; Martel, I

    2014-08-01

    An artificially grown high purity diamond was used as a detector for alpha-particle spectrometry. Diamond detectors can match the performance of silicon detectors employed in standard continuous air monitoring systems. Its radiation hardness and electronic properties make them ideal to work under extreme condition such as high temperature and ambient lights. A 50 μm thickness single-crystal diamond detector has been compared with a 300 μm passivated implanted planar silicon detector, under ambient conditions.

  1. Estimating the probability of failure when testing reveals no failures

    NASA Technical Reports Server (NTRS)

    Miller, Keith W.; Morell, Larry J.; Noonan, Robert E.; Park, Stephen K.; Nicol, David M.; Murrill, Branson W.; Voas, Jeffrey M.

    1992-01-01

    Formulas for estimating the probability of failure when testing reveals no errors are introduced. These formulas incorporate random testing results, information about the input distribution, and prior assumptions about the probability of failure of the software. The formulas are not restricted to equally likely input distributions, and the probability of failure estimate can be adjusted when assumptions about the input distribution change. The formulas are based on a discrete sample space statistical model of software and include Bayesian prior assumptions. Reusable software and software in life-critical applications are particularly appropriate candidates for this type of analysis.

  2. Detectors in medical physics measuring dose by detectors

    NASA Astrophysics Data System (ADS)

    Alrowaili, Ziyad

    The doses were measured at the depth of 10 cm and at the maximum dose dmax for two energies 6 MV photon and 10 MV photon on Elekta machine. Measuring dose was done by using only two points and comparing the results with percentage depth dose (PDD) for the depth dose curve for both energies. In addition the doses were obtained by using three methods of detectors to measure the dose by using the ion chamber, Thermo luminescence, and films. The results obtained for three measurements agreed within 2% for 6 MV photon and 3% for 10 MV photon by using three different detectors in the clinic. Therefore, these detectors are stable and reliable to be used in clinical applications.

  3. Low background IR detector and detector array evaluations

    NASA Technical Reports Server (NTRS)

    Goebel, J. H.; Jared, D. A.; Lee, J. H.; Mccreight, C. R.; Mckelvey, M. E.; Stafford, P. S.

    1983-01-01

    A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

  4. JWST Near-Infrared Detector Degradation: Finding the Problem, Fixing the Problem, and Moving Forward

    NASA Technical Reports Server (NTRS)

    Rauscher, Bernard J.; Stahle, Carl; Hill, Bob; Greenhouse, Matt; Beletic, James; Babu, Sachidananda; Blake, Peter; Cleveland, Keith; Cofie, Emmanuel; Eegholm, Bente; Engelbracht, Chad; Hall, Don; Hoffman, Alan; Jeffers, Basil; Jhabvala, Christine; Kimble, Randy; Kopp, Robert; Lee, Don; Leidecker, Henning; Lindler, Don; McMurray, Bob; Mott, D. Brent; Ohl, Ray; Polis, Don; Pontius, Jim

    2012-01-01

    The James Webb Space Telescope (JWST) is the successor to the Hubble Space Telescope. JWST will be an infrared optimized telescope, with an approximately 6.5 m diameter primary mirror, that is located at the Sun-Earth L2 Lagrange point. Three of JWST's four science instruments use Teledyne HgCdTe HAWAII-2RG (H2RG) near infrared detector arrays. During 2010, the JWST Project noticed that a few of its 5 micron cutoff H2RG detectors were degrading during room temperature storage, and NASA chartered a "Detector Degradation Failure Review Board" (DD-FRB) to investigate. The DD-FRB determined that the root cause was a design flaw that allowed indium to interdiffuse with the gold contacts and migrate into the HgCdTe detector layer. Fortunately, Teledyne already had an improved design that eliminated this degradation mechanism. During early 2012, the improved H2RG design was qualified for flight and JWST began making additional H2RGs. In this article we present the two public DD-FRB "Executiye Summaries" that: (1) determined the root cause of the detector degradation and (2) defined tests to determine whether the existing detectors are qualified for flight. We supplement these with a brief introduction to H2RG detector arrays, and a discussion of how the JWST Project is using cryogenic storage to retard the degradation rate of the existing flight spare H2RGs.

  5. Performance in space of the AMS-02 RICH detector

    NASA Astrophysics Data System (ADS)

    Giovacchini, F.

    2014-12-01

    AMS-02 was successfully installed on the International Space Station (ISS) in May 2011, to perform precise measurements of galactic cosmic rays in the 100 MV to few TV magnetic rigidity range. Among several specialized sub-detectors, AMS-02 includes a Ring Imaging Cherenkov detector (RICH), which provides a precise measurement of the particle charge and velocity. The Cherenkov light is produced in a radiator made of silica aerogel and sodium fluoride and collected by means of an array of photomultiplier tubes. Since its launch to space, the detector has been taking data without failures; its functionality and data integrity are monitored and show stable response. In order to achieve the optimal detector performance, calibrations have been performed to account for the dependence of the photodetectors response on temperature and for effective non-uniformities in the detector. The knowledge gathered of the photon yield at the percent level resulted in a charge resolution of 0.3 charge units for He and 0.5 charge units for Si ions. The required precision in the measurements of the particle velocity at the per mil level demanded a more accurate determination of the aerogel refractive index. A map of the aerogel radiator refractive index has been directly inferred from in-flight high statistics data with a precision of Δn / n < 2 ×10-5 on average and its stability with time has also been checked. Finally, a velocity resolution of 0.8 ×10-3 for He and 0.5 ×10-3 for Z > 5 ions has been obtained.

  6. Premature ovarian failure

    PubMed Central

    Beck-Peccoz, Paolo; Persani, Luca

    2006-01-01

    Premature ovarian failure (POF) is a primary ovarian defect characterized by absent menarche (primary amenorrhea) or premature depletion of ovarian follicles before the age of 40 years (secondary amenorrhea). It is a heterogeneous disorder affecting approximately 1% of women <40 years, 1:10,000 women by age 20 and 1:1,000 women by age 30. The most severe forms present with absent pubertal development and primary amenorrhea (50% of these cases due to ovarian dysgenesis), whereas forms with post-pubertal onset are characterized by disappearance of menstrual cycles (secondary amenorrhea) associated with premature follicular depletion. As in the case of physiological menopause, POF presents by typical manifestations of climacterium: infertility associated with palpitations, heat intolerance, flushes, anxiety, depression, fatigue. POF is biochemically characterized by low levels of gonadal hormones (estrogens and inhibins) and high levels of gonadotropins (LH and FSH) (hypergonadotropic amenorrhea). Beyond infertility, hormone defects may cause severe neurological, metabolic or cardiovascular consequences and lead to the early onset of osteoporosis. Heterogeneity of POF is also reflected by the variety of possible causes, including autoimmunity, toxics, drugs, as well as genetic defects. POF has a strong genetic component. X chromosome abnormalities (e.g. Turner syndrome) represent the major cause of primary amenorrhea associated with ovarian dysgenesis. Despite the description of several candidate genes, the cause of POF remains undetermined in the vast majority of the cases. Management includes substitution of the hormone defect by estrogen/progestin preparations. The only solution presently available for the fertility defect in women with absent follicular reserve is ovum donation. PMID:16722528

  7. Report on Advanced Detector Development

    SciTech Connect

    James K. Jewell

    2012-09-01

    Neutron, gamma and charged particle detection improvements are key to supporting many of the foreseen measurements and systems envisioned in the R&D programs and the future fuel cycle requirements, such as basic nuclear physics and data, modeling and simulation, reactor instrumentation, criticality safety, materials management and safeguards. This task will focus on the developmental needs of the FCR&D experimental programs, such as elastic/inelastic scattering, total cross sections and fission neutron spectra measurements, and will leverage a number of existing neutron detector development efforts and programs, such as those at LANL, PNNL, INL, and IAC as well as those at many universities, some of whom are funded under NE grants and contracts. Novel materials and fabrication processes combined with state-of-the-art electronics and computing provide new opportunities for revolutionary detector systems that will be able to meet the high precision needs of the program. This work will be closely coordinated with the Nuclear Data Crosscut. The Advanced Detector Development effort is a broadly-focused activity that supports the development of improved nuclear data measurements and improved detection of nuclear reactions and reactor conditions. This work supports the design and construction of large-scale, multiple component detectors to provide nuclear reaction data of unprecedented quality and precision. Examples include the Time Projection Chamber (TPC) and the DANCE detector at LANL. This work also supports the fabrication and end-user application of novel scintillator materials detection and monitoring.

  8. High precision thermal neutron detectors

    SciTech Connect

    Radeka, V.; Schaknowski, N.A.; Smith, G.C.; Yu, B.

    1994-12-31

    Two-dimensional position sensitive detectors are indispensable in neutron diffraction experiments for determination of molecular and crystal structures in biology, solid-state physics and polymer chemistry. Some performance characteristics of these detectors are elementary and obvious, such as the position resolution, number of resolution elements, neutron detection efficiency, counting rate and sensitivity to gamma-ray background. High performance detectors are distinguished by more subtle characteristics such as the stability of the response (efficiency) versus position, stability of the recorded neutron positions, dynamic range, blooming or halo effects. While relatively few of them are needed around the world, these high performance devices are sophisticated and fairly complex, their development requires very specialized efforts. In this context, we describe here a program of detector development, based on {sup 3}He filled proportional chambers, which has been underway for some years at the Brookhaven National Laboratory. Fundamental approaches and practical considerations are outlined that have resulted in a series of high performance detectors with the best known position resolution, position stability, uniformity of response and reliability over time, for devices of this type.

  9. Capacitor-type micrometeoroid detectors

    NASA Technical Reports Server (NTRS)

    Wortman, J. J.; Griffis, D. P.; Bryan, S. R.; Kinard, W.

    1986-01-01

    The metal oxide semiconductor (MOS) capacitor micrometeroid detector consists of a thin dielectric capacitor fabricated on a silicon wafer. In operation, the device is charged to a voltage level sufficiently near breakdown that micrometeoroid impacts will cause dielectric deformation or heating and subsequent arc-over at the point of impact. Each detector is capable of recording multiple impacts because of the self-healing characteristics of the device. Support instrumentation requirements consist of a voltage source and pulse counters that monitor the pulse of recharging current following every impact. An investigation has been conducted in which 0.5 to 5 micron diameter carbonized iron spheres traveling at velocities of 4 to 10 Km/sec were impacted on to detectors with either a dielectric thickness of 0.4 or 1.0 micron. This study demonstrated that an ion microprobe tuned to sufficiently high resolution can detect Fe remaining on the detector after the impact. Furthermore, it is also possible to resolve Fe ion images free of mass interferences from Si, for example, giving its spatial distribution after impact. Specifically this technique has shown that significant amounts of impacting particles remain in the crater and near it which can be analyzed for isotopic content. Further testing and calibration could lead to quantitive analysis. This study has shown that the capacitor type micrometeroid detector is capable of not only time and flux measurements but can also be used for isotopic analysis.

  10. Near infrared detectors for SNAP

    SciTech Connect

    Schubnell, M.; Barron, N.; Bebek, C.; Brown, M.G.; Borysow, M.; Cole, D.; Figer, D.; Lorenzon, W.; Mostek, N.; Mufson, S.; Seshadri, S.; Smith, R.; Tarle, G.

    2006-05-23

    Large format (1k x 1k and 2k x 2k) near infrared detectors manufactured by Rockwell Scientific Center and Raytheon Vision Systems are characterized as part of the near infrared R&D effort for SNAP (the Super-Nova/Acceleration Probe). These are hybridized HgCdTe focal plane arrays with a sharp high wavelength cut-off at 1.7 um. This cut-off provides a sufficiently deep reach in redshift while it allows at the same time low dark current operation of the passively cooled detectors at 140 K. Here the baseline SNAP near infrared system is briefly described and the science driven requirements for the near infrared detectors are summarized. A few results obtained during the testing of engineering grade near infrared devices procured for the SNAP project are highlighted. In particular some recent measurements that target correlated noise between adjacent detector pixels due to capacitive coupling and the response uniformity within individual detector pixels are discussed.

  11. Metal detector technology data base

    SciTech Connect

    Porter, L.K.; Gallo, L.R.; Murray, D.W.

    1990-08-01

    The tests described in this report were conducted to obtain information on the effects target characteristics have on portal type metal detector response. A second purpose of the tests was to determine the effect of detector type and settings on the detection of the targets. Although in some cases comparison performance of different types and makes of metal detectors is found herein, that is not the primary purpose of the report. Further, because of the many variables that affect metal detector performance, the information presented can be used only in a general way. The results of these tests can show general trends in metal detection, but do little for making accurate predictions as to metal detector response to a target with a complex shape such as a handgun. The shape of an object and its specific metal content (both type and treatment) can have a significant influence on detection. Thus it should not be surprising that levels of detection for a small 100g stainless steel handgun are considerably different than for detection of the 100g stainless steel right circular cylinder that was used in these tests. 7 figs., 1 tab.

  12. The EXO-200 detector, part I: detector design and construction

    NASA Astrophysics Data System (ADS)

    Auger, M.; Auty, D. J.; Barbeau, P. S.; Bartoszek, L.; Baussan, E.; Beauchamp, E.; Benitez-Medina, C.; Breidenbach, M.; Chauhan, D.; Cleveland, B.; Conley, R.; Cook, J.; Cook, S.; Coppens, A.; Craddock, W.; Daniels, T.; Davis, C. G.; Davis, J.; deVoe, R.; Dobi, A.; Dolinski, M. J.; Dunford, M.; Fairbank, W., Jr.; Farine, J.; Fierlinger, P.; Franco, D.; Giroux, G.; Gornea, R.; Graham, K.; Gratta, G.; Hagemann, C.; Hall, C.; Hall, K.; Hargrove, C.; Herrin, S.; Hodgson, J.; Hughes, M.; Karelin, A.; Kaufman, L. J.; Kirk, J.; Kuchenkov, A.; Kumar, K. S.; Leonard, D. S.; Leonard, F.; LePort, F.; Mackay, D.; MacLellan, R.; Marino, M.; Merkle, K.; Mong, B.; Montero Díez, M.; Müller, A. R.; Neilson, R.; Odian, A.; O'Sullivan, K.; Ouellet, C.; Piepke, A.; Pocar, A.; Prescott, C. Y.; Pushkin, K.; Rivas, A.; Rollin, E.; Rowson, P. C.; Sabourov, A.; Sinclair, D.; Skarpaas, K.; Slutsky, S.; Stekhanov, V.; Strickland, V.; Swift, M.; Tosi, D.; Twelker, K.; Vuilleumier, J.-L.; Vuilleumier, J.-M.; Walton, T.; Weber, M.; Wichoski, U.; Wodin, J.; Wright, J. D.; Yang, L.; Yen, Y.-R.

    2012-05-01

    EXO-200 is an experiment designed to search for double beta decay of 136Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low background time projection chamber capable of simultaneous detection of ionization and scintillation. This paper describes the EXO-200 detector with particular attention to the most innovative aspects of the design that revolve around the reduction of backgrounds, the efficient use of the expensive isotopically enriched xenon, and the optimization of the energy resolution in a relatively large volume.

  13. Energy metabolism in heart failure

    PubMed Central

    Ventura-Clapier, Renée; Garnier, Anne; Veksler, Vladimir

    2004-01-01

    Heart failure (HF) is a syndrome resulting from the inability of the cardiac pump to meet the energy requirements of the body. Despite intensive work, the pathogenesis of the cardiac intracellular abnormalities that result from HF remains incompletely understood. Factors that lead to abnormal contraction and relaxation in the failing heart include metabolic pathway abnormalities that result in decreased energy production, energy transfer and energy utilization. Heart failure also affects the periphery. Patients suffering from heart failure always complain of early muscular fatigue and exercise intolerance. This is linked in part to intrinsic alterations of skeletal muscle, among which decreases in the mitochondrial ATP production and in the transfer of energy through the phosphotransfer kinases play an important role. Alterations in energy metabolism that affect both cardiac and skeletal muscles argue for a generalized metabolic myopathy in heart failure. Recent evidence shows that decreased expression of mitochondrial transcription factors and mitochondrial proteins are involved in mechanisms causing the energy starvation in heart failure. This review will focus on energy metabolism alterations in long-term chronic heart failure with only a few references to compensated hypertrophy when necessary. It will briefly describe the energy metabolism of normal heart and skeletal muscles and their alterations in chronic heart failure. It is beyond the scope of this review to address the metabolic switches occurring in compensated hypertrophy; readers could refer to well-documented reviews on this subject. PMID:14660709

  14. Failure environment analysis tool applications

    NASA Technical Reports Server (NTRS)

    Pack, Ginger L.; Wadsworth, David B.

    1994-01-01

    Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within it, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.

  15. Failure environment analysis tool applications

    NASA Technical Reports Server (NTRS)

    Pack, Ginger L.; Wadsworth, David B.

    1993-01-01

    Understanding risks and avoiding failure are daily concerns for the women and men of NASA. Although NASA's mission propels us to push the limits of technology, and though the risks are considerable, the NASA community has instilled within, the determination to preserve the integrity of the systems upon which our mission and, our employees lives and well-being depend. One of the ways this is being done is by expanding and improving the tools used to perform risk assessment. The Failure Environment Analysis Tool (FEAT) was developed to help engineers and analysts more thoroughly and reliably conduct risk assessment and failure analysis. FEAT accomplishes this by providing answers to questions regarding what might have caused a particular failure; or, conversely, what effect the occurrence of a failure might have on an entire system. Additionally, FEAT can determine what common causes could have resulted in other combinations of failures. FEAT will even help determine the vulnerability of a system to failures, in light of reduced capability. FEAT also is useful in training personnel who must develop an understanding of particular systems. FEAT facilitates training on system behavior, by providing an automated environment in which to conduct 'what-if' evaluation. These types of analyses make FEAT a valuable tool for engineers and operations personnel in the design, analysis, and operation of NASA space systems.

  16. Periodontitis in Chronic Heart Failure

    PubMed Central

    Fröhlich, Hanna; Herrmann, Kristina; Franke, Jennifer; Karimi, Alamara; Täger, Tobias; Cebola, Rita; Katus, Hugo A.; Zugck, Christian

    2016-01-01

    Periodontal disease has been associated with an increased risk of cardiovascular events. The purpose of our study was to investigate whether a correlation between periodontitis and chronic heart failure exists, as well as the nature of the underlying cause. We enrolled 71 patients (mean age, 54 ± 13 yr; 56 men) who had stable chronic heart failure; all underwent complete cardiologic and dental evaluations. The periodontal screening index was used to quantify the degree of periodontal disease. We compared the findings to those in the general population with use of data from the 4th German Dental Health Survey. Gingivitis, moderate periodontitis, and severe periodontitis were present in 17 (24%), 17 (24%), and 37 (52%) patients, respectively. Severe periodontitis was more prevalent among chronic heart failure patients than in the general population. In contrast, moderate periodontitis was more prevalent in the general population (P <0.00001). The severity of periodontal disease was not associated with the cause of chronic heart failure or the severity of heart failure symptoms. Six-minute walking distance was the only independent predictor of severe periodontitis. Periodontal disease is highly prevalent in chronic heart failure patients regardless of the cause of heart failure. Prospective trials are warranted to clarify the causal relationship between both diseases. PMID:27547136

  17. Failure Analysis and Mechanisms of Failure of Fibrous Composite Structures

    NASA Technical Reports Server (NTRS)

    Noor, A. K. (Compiler); Shuart, M. J. (Compiler); Starnes, J. H., Jr. (Compiler); Williams, J. G. (Compiler)

    1983-01-01

    The state of the art of failure analysis and current design practices, especially as applied to the use of fibrous composite materials in aircraft structures is discussed. Deficiencies in these technologies are identified, as are directions for future research.

  18. Failure probability under parameter uncertainty.

    PubMed

    Gerrard, R; Tsanakas, A

    2011-05-01

    In many problems of risk analysis, failure is equivalent to the event of a random risk factor exceeding a given threshold. Failure probabilities can be controlled if a decisionmaker is able to set the threshold at an appropriate level. This abstract situation applies, for example, to environmental risks with infrastructure controls; to supply chain risks with inventory controls; and to insurance solvency risks with capital controls. However, uncertainty around the distribution of the risk factor implies that parameter error will be present and the measures taken to control failure probabilities may not be effective. We show that parameter uncertainty increases the probability (understood as expected frequency) of failures. For a large class of loss distributions, arising from increasing transformations of location-scale families (including the log-normal, Weibull, and Pareto distributions), the article shows that failure probabilities can be exactly calculated, as they are independent of the true (but unknown) parameters. Hence it is possible to obtain an explicit measure of the effect of parameter uncertainty on failure probability. Failure probability can be controlled in two different ways: (1) by reducing the nominal required failure probability, depending on the size of the available data set, and (2) by modifying of the distribution itself that is used to calculate the risk control. Approach (1) corresponds to a frequentist/regulatory view of probability, while approach (2) is consistent with a Bayesian/personalistic view. We furthermore show that the two approaches are consistent in achieving the required failure probability. Finally, we briefly discuss the effects of data pooling and its systemic risk implications.

  19. Success and failure of biological treatment in systemic lupus erythematosus: A critical analysis.

    PubMed

    Gatto, Mariele; Saccon, Francesca; Zen, Margherita; Bettio, Silvano; Iaccarino, Luca; Punzi, Leonardo; Doria, Andrea

    2016-11-01

    Patients affected with systemic lupus erythematosus (SLE) still display increased mortality and decreased quality of life in respect to general population. The major determinant of poor long term prognosis is organ damage, which is predictive of more damage and death. Damage is in turn triggered by uncontrolled disease activity and especially by the long-standing corticosteroid use which often accompanies SLE patients over their disease course, owing both to the need of reaching disease remission and to the habit of keeping patients on a small steroid dose for an indefinite period of time. Hence, the need for new drugs and therapeutic strategies aiming at minimizing damage accrual through a better control of disease activity and a steroid-sparing potential is paramount. So far, however, the therapeutic strategy in SLE requires a multitarget approach which is not devoid of widespread immunesuppression. In fact, several studies have been carried out in recent years targeting both the adaptive and the innate immune system, the majority of which did not achieve their primary endpoint, being often divergent from successful clinical experience and thereby committing physician to off-label use of targeted therapies in face of refractory SLE manifestations. The study designs and the chosen endpoints were often blamed for inadequacy, being at least in part responsible for study failures. In this review, we go over major clinical trials conducted in SLE by analyzing any critical aspects related to study design, predefined endpoints and biological activity of novel compounds that may have hampered study outcome, despite the great effort of providing less toxic drugs within a targeted, pathogenic-based approach.

  20. Failure Mode Classification for Life Prediction Modeling of Solid-State Lighting

    SciTech Connect

    Sakalaukus, Peter Joseph

    2015-08-01

    light power” of the SSL luminaire. The use of the Arrhenius equation necessitates two different temperature conditions, 25°C and 45°C are suggested by TM28, to determine the SSL lamp specific activation energy. One principal issue with TM28 is the lack of additional stresses or parameters needed to characterize non-temperature dependent failure mechanisms. Another principal issue with TM28 is the assumption that lumen maintenance or lumen depreciation gives an adequate comparison between SSL luminaires. Additionally, TM28 has no process for the determination of acceleration factors or lifetime estimations. Currently, a literature gap exists for established accelerated test methods for SSL devices to assess quality, reliability and durability before being introduced into the marketplace. Furthermore, there is a need for Physics-of-Failure based approaches to understand the processes and mechanisms that induce failure for the assessment of SSL reliability in order to develop generalized acceleration factors that better represent SSL product lifetime. This and the deficiencies in TM28 validate the need behind the development of acceleration techniques to quantify SSL reliability under a variety of environmental conditions. The ability to assess damage accrual and investigate reliability of SSL components and systems is essential to understanding the life time of the SSL device itself. The methodologies developed in this work increases the understanding of SSL devices iv through the investigation of component and device reliability under a variety of accelerated test conditions. The approaches for suitable lifetime predictions through the development of novel generalized acceleration factors, as well as a prognostics and health management framework, will greatly reduce the time and effort needed to produce SSL acceleration factors for the development of lifetime predictions.