Science.gov

Sample records for accuracy tandem mass

  1. MS Amanda, a Universal Identification Algorithm Optimized for High Accuracy Tandem Mass Spectra

    PubMed Central

    2014-01-01

    Today’s highly accurate spectra provided by modern tandem mass spectrometers offer considerable advantages for the analysis of proteomic samples of increased complexity. Among other factors, the quantity of reliably identified peptides is considerably influenced by the peptide identification algorithm. While most widely used search engines were developed when high-resolution mass spectrometry data were not readily available for fragment ion masses, we have designed a scoring algorithm particularly suitable for high mass accuracy. Our algorithm, MS Amanda, is generally applicable to HCD, ETD, and CID fragmentation type data. The algorithm confidently explains more spectra at the same false discovery rate than Mascot or SEQUEST on examined high mass accuracy data sets, with excellent overlap and identical peptide sequence identification for most spectra also explained by Mascot or SEQUEST. MS Amanda, available at http://ms.imp.ac.at/?goto=msamanda, is provided free of charge both as standalone version for integration into custom workflows and as a plugin for the Proteome Discoverer platform. PMID:24909410

  2. Quality evaluation of tandem mass spectral libraries.

    PubMed

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  3. Peptide identification by database search of mixture tandem mass spectra.

    PubMed

    Wang, Jian; Bourne, Philip E; Bandeira, Nuno

    2011-12-01

    In high-throughput proteomics the development of computational methods and novel experimental strategies often rely on each other. In certain areas, mass spectrometry methods for data acquisition are ahead of computational methods to interpret the resulting tandem mass spectra. Particularly, although there are numerous situations in which a mixture tandem mass spectrum can contain fragment ions from two or more peptides, nearly all database search tools still make the assumption that each tandem mass spectrum comes from one peptide. Common examples include mixture spectra from co-eluting peptides in complex samples, spectra generated from data-independent acquisition methods, and spectra from peptides with complex post-translational modifications. We propose a new database search tool (MixDB) that is able to identify mixture tandem mass spectra from more than one peptide. We show that peptides can be reliably identified with up to 95% accuracy from mixture spectra while considering only a 0.01% of all possible peptide pairs (four orders of magnitude speedup). Comparison with current database search methods indicates that our approach has better or comparable sensitivity and precision at identifying single-peptide spectra while simultaneously being able to identify 38% more peptides from mixture spectra at significantly higher precision.

  4. DeconMSn: A Software Tool for accurate parent ion monoisotopic mass determination for tandem mass spectra

    SciTech Connect

    Mayampurath, Anoop M.; Jaitly, Navdeep; Purvine, Samuel O.; Monroe, Matthew E.; Auberry, Kenneth J.; Adkins, Joshua N.; Smith, Richard D.

    2008-04-01

    We present a new software tool for tandem MS analyses that: • accurately calculates the monoisotopic mass and charge of high–resolution parent ions • accurately operates regardless of the mass selected for fragmentation • performs independent of instrument settings • enables optimal selection of search mass tolerance for high mass accuracy experiments • is open source and thus can be tailored to individual needs • incorporates a SVM-based charge detection algorithm for analyzing low resolution tandem MS spectra • creates multiple output data formats (.dta, .MGF) • handles .RAW files and .mzXML formats • compatible with SEQUEST, MASCOT, X!Tandem

  5. Liquid chromatography-high resolution/ high accuracy (tandem) mass spectrometry-based identification of in vivo generated metabolites of the selective androgen receptor modulator ACP-105 for doping control purposes.

    PubMed

    Thevis, Mario; Thomas, Andreas; Piper, Thomas; Krug, Oliver; Delahaut, Philippe; Schänzer, Wilhelm

    2014-01-01

    Selective androgen receptor modulators (SARMs) represent an emerging class of therapeutics which have been prohibited in sport as anabolic agents according to the regulations of the World Anti-Doping Agency (WADA) since 2008. Within the past three years, numerous adverse analytical findings with SARMs in routine doping control samples have been reported despite missing clinical approval of these substances. Hence, preventive doping research concerning the metabolism and elimination of new therapeutic entities of the class of SARMs are vital for efficient and timely sports drug testing programs as banned compounds are most efficiently screened when viable targets (for example, characteristic metabolites) are identified. In the present study, the metabolism of ACP-105, a novel SARM drug candidate, was studied in vivo in rats. Following oral administration, urine samples were collected over a period of seven days and analyzed for metabolic products by Liquid chromatography-high resolution/high accuracy (tandem) mass spectrometry. Samples were subjected to enzymatic hydrolysis prior to liquid-liquid extraction and a total of seven major phase-I metabolites were detected, three of which were attributed to monohydroxylated and four to bishydroxylated ACP-105. The hydroxylation sites were assigned by means of diagnostic product ions and respective dissociation pathways of the analytes following positive or negative ionization and collisional activation as well as selective chemical derivatization. The identified metabolites were used as target compounds to investigate their traceability in a rat elimination urine samples study and monohydroxylated and bishydroxylated species were detectable for up to four and six days post-administration, respectively.

  6. Electrospray and tandem mass spectrometry in biochemistry.

    PubMed Central

    Griffiths, W J; Jonsson, A P; Liu, S; Rai, D K; Wang, Y

    2001-01-01

    Over the last 20 years, biological MS has changed out of all recognition. This is primarily due to the development in the 1980s of 'soft ionization' methods that permit the ionization and vaporization of large, polar, and thermally labile biomolecules. These developments in ionization mode have driven the design and manufacture of smaller and cheaper mass analysers, making the mass spectrometer a routine instrument in the biochemistry laboratory today. In the present review the revolutionary 'soft ionization' methods will be discussed with particular reference to electrospray. The mass analysis of ions will be described, and the concept of tandem MS introduced. Where appropriate, examples of the application of MS in biochemistry will be provided. Although the present review will concentrate on the MS of peptides/proteins and lipids, all classes of biomolecules can be analysed, and much excellent work has been done in the fields of carbohydrate and nucleic acid biochemistry. PMID:11311115

  7. High-sensitivity mass spectrometry with a tandem accelerator

    SciTech Connect

    Henning, W.

    1983-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems.

  8. Protein Sequencing with Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Ziady, Assem G.; Kinter, Michael

    The recent introduction of electrospray ionization techniques that are suitable for peptides and whole proteins has allowed for the design of mass spectrometric protocols that provide accurate sequence information for proteins. The advantages gained by these approaches over traditional Edman Degradation sequencing include faster analysis and femtomole, sometimes attomole, sensitivity. The ability to efficiently identify proteins has allowed investigators to conduct studies on their differential expression or modification in response to various treatments or disease states. In this chapter, we discuss the use of electrospray tandem mass spectrometry, a technique whereby protein-derived peptides are subjected to fragmentation in the gas phase, revealing sequence information for the protein. This powerful technique has been instrumental for the study of proteins and markers associated with various disorders, including heart disease, cancer, and cystic fibrosis. We use the study of protein expression in cystic fibrosis as an example.

  9. Tandem mass spectrometry studies of metallofullerenes

    SciTech Connect

    Callahan, J.H.; Nelson, H.; McElvany, S.W.; Ross, M.M.

    1993-12-31

    As interest in the chemistry of fullerenes grows, many laboratories are now directing their efforts toward the synthesis of fullerene derivatives such as metallofullerenes (endohedral complexes). Tandem mass spectrometry has proven useful in the characterization of such derivatives. In tandem mass spectrometry, ions of interest are selected with one mass analyzer, collided or reacted with a gas, and the products of the reaction are subsequently analyzed with an additional stage of mass analysis. The authors have used low- and high-energy collisions with reactive and inert target gas molecules to probe the structures, properties and reactivities of endohedral metallofullerene complexes. These studies have shown that metallofullerenes have properties similar to those of fullerenes, including the ability to take up He during keV collisions, forming complexes such as La{sub 2}He@C{sub 80} These studies indicate that the metal is not on the outside of the cage, although the formation of La{sub 2}He@C{sub 80} suggests that one of the metal atoms may be incorporated as part of the cage. Fragmentation processes in the metallofullerenes are similar to those of the fullerenes (e.g. successive C{sub 2} loss), lending further support for the proposed endohedral structure of the fullerenes. The behavior of the metallofullerenes in reactive collisions with oxygen has also been studied, indicating that their reactivities are similar to those of the fullerenes. Fourier transform spectroscopy studies are currently underway to further probe the reactivities, ionization energies and gas phase proton affinities of the metallofullerenes.

  10. Tandem mass spectrometry of low solubility polyamides.

    PubMed

    Barrère, Caroline; Hubert-Roux, Marie; Afonso, Carlos; Rejaibi, Majed; Kebir, Nasreddine; Désilles, Nicolas; Lecamp, Laurence; Burel, Fabrice; Loutelier-Bourhis, Corinne

    2014-01-15

    The structural characterization of polyamides (PA) was achieved by tandem mass spectrometry (MS/MS) with a laser induced dissociation (LID) strategy. Because of interferences for precursor ions selection, two chemical modifications of the polymer end groups were proposed as derivatization strategies. The first approach, based on the addition of a trifluoroacetic acid (TFA) molecule, yields principally to complementary bn and yn product ions. This fragmentation types, analogous to those obtained with peptides or other PA, give only poor characterization of polymer end-groups [1]. A second approach, based on the addition of a basic diethylamine (DEA), permits to fix the charge and favorably direct the fragmentation. In this case, bn ions were not observed. The full characterization of ω end group structure was obtained, in addition to the expected yn and consecutive fragment ions. PMID:24370089

  11. Tandem mass spectrometry of low solubility polyamides.

    PubMed

    Barrère, Caroline; Hubert-Roux, Marie; Afonso, Carlos; Rejaibi, Majed; Kebir, Nasreddine; Désilles, Nicolas; Lecamp, Laurence; Burel, Fabrice; Loutelier-Bourhis, Corinne

    2014-01-15

    The structural characterization of polyamides (PA) was achieved by tandem mass spectrometry (MS/MS) with a laser induced dissociation (LID) strategy. Because of interferences for precursor ions selection, two chemical modifications of the polymer end groups were proposed as derivatization strategies. The first approach, based on the addition of a trifluoroacetic acid (TFA) molecule, yields principally to complementary bn and yn product ions. This fragmentation types, analogous to those obtained with peptides or other PA, give only poor characterization of polymer end-groups [1]. A second approach, based on the addition of a basic diethylamine (DEA), permits to fix the charge and favorably direct the fragmentation. In this case, bn ions were not observed. The full characterization of ω end group structure was obtained, in addition to the expected yn and consecutive fragment ions.

  12. Improved Isobaric Tandem Mass Tag Quantification by Ion Mobility-Mass Spectrometry

    PubMed Central

    Li, Lingjun

    2014-01-01

    Isobaric tandem mass tags are an attractive alternative to mass difference tags and label free approaches for quantitative proteomics due to the high degree of multiplexing that can be performed with their implementation. A drawback of tandem mass tags are that the co-isolation and co-fragmentation of labeled peptide precursors can result in chimeric MS/MS spectra that can underestimate the fold-change expression of each peptide. Two methods (QuantMode and MS3) have addressed this concern for ion trap and orbitrap instruments, but there is still a need to solve this problem for quadrupole time-of-flight (Q-TOF) instruments. Ion mobility (IM) separations coupled to Q-TOF instruments have the potential to mitigate MS/MS spectra chimeracy since IM-MS has the ability to separate ions based on charge, m/z, and collision cross section (CCS). This work presents results that showcase the power of IM-MS to improve tandem mass tag peptide quantitation accuracy by resolving co-isolated differently charged and same charged peptides prior to MS/MS fragmentation. PMID:24677527

  13. Accelerator mass spectrometry at the 4 MV Dynamitron Tandem in Bochum

    NASA Astrophysics Data System (ADS)

    Lubritto, C.; Rogalla, D.; Rubino, M.; Marzaioli, F.; Passariello, I.; Romano, M.; Spadaccini, G.; Casa, G.; Di Leva, A.; De Cesare, N.; D'Onofrio, A.; Gialanella, L.; Imbriani, G.; Palmieri, A.; Roca, V.; Rolfs, C.; Sabbarese, C.; Strieder, F.; Schüermann, D.; Terrasi, F.

    2004-07-01

    A feasibility test for Accelerator Mass Spectrometry has been carried out successfully at the 4 MV Dynamitron Tandem Laboratory in Bochum in conjunction with a new recoil separator. We describe the facility as well as results concerning the reproducibility and accuracy of 14C content measurements of several standard samples.

  14. Mass Resolution and Mass Accuracy: How Much Is Enough?

    PubMed Central

    G. Marshall, Alan; T. Blakney, Greg; Chen, Tong; K. Kaiser, Nathan; M. McKenna, Amy; P. Rodgers, Ryan; M. Ruddy, Brian; Xian, Feng

    2013-01-01

    Accurate mass measurement requires the highest possible mass resolution, to ensure that only a single elemental composition contributes to the mass spectral peak in question. Although mass resolution is conventionally defined as the closest distinguishable separation between two peaks of equal height and width, the required mass resolving power can be ∼10× higher for equal width peaks whose peak height ratio is 100 : 1. Ergo, minimum resolving power requires specification of maximum dynamic range, and is thus 10–100× higher than the conventional definition. Mass resolving power also depends on mass-to-charge ratio. Mass accuracy depends on mass spectral signal-to-noise ratio and digital resolution. Finally, the reliability of elemental composition assignment can be improved by resolution of isotopic fine structure. Thus, the answer to the question of “how much is enough mass resolving power” requires that one first specify S/N ratio, dynamic range, digital resolution, mass-to-charge ratio, and (if available) isotopic fine structure. The highest available broadband mass resolving power and mass accuracy is from Fourier transform ion cyclotron resonance mass spectrometry. Over the past five years, FT-ICR MS mass accuracy has improved by about an order of magnitude, based on higher magnetic field strength, conditional averaging of time-domain transients, better mass calibration (spectral segmentation; inclusion of a space charge term); radially dispersed excitation; phase correction to yield absorption-mode display; and new ICR cell segmentation designs. PMID:24349928

  15. Crux: rapid open source protein tandem mass spectrometry analysis.

    PubMed

    McIlwain, Sean; Tamura, Kaipo; Kertesz-Farkas, Attila; Grant, Charles E; Diament, Benjamin; Frewen, Barbara; Howbert, J Jeffry; Hoopmann, Michael R; Käll, Lukas; Eng, Jimmy K; MacCoss, Michael J; Noble, William Stafford

    2014-10-01

    Efficiently and accurately analyzing big protein tandem mass spectrometry data sets requires robust software that incorporates state-of-the-art computational, machine learning, and statistical methods. The Crux mass spectrometry analysis software toolkit ( http://cruxtoolkit.sourceforge.net ) is an open source project that aims to provide users with a cross-platform suite of analysis tools for interpreting protein mass spectrometry data. PMID:25182276

  16. High Mass Accuracy and High Mass Resolving Power FT-ICR Secondary Ion Mass Spectrometry for Biological Tissue Imaging

    SciTech Connect

    Smith, Donald F.; Kiss, Andras; Leach, Franklin E.; Robinson, Errol W.; Pasa-Tolic, Ljiljana; Heeren, Ronald M.

    2013-07-01

    Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for exact mass elemental formula assignment. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (m/Δm50%) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with m/Δm50% > 3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.

  17. Determination of dalcetrapib by liquid chromatography-tandem mass spectrometry.

    PubMed

    Heinig, Katja; Bucheli, Franz; Kuhlmann, Olaf; Zell, Manfred; Pähler, Axel; Zwanziger, Elke; Gross, Günter; Tardio, Joseph; Ishikawa, Tomohiro; Yamashita, Tomoko

    2012-07-01

    The cholesteryl ester transfer protein modulator dalcetrapib is currently under development for the prevention of dyslipidemia and cardiovascular disease. Dalcetrapib, a thioester, is rapidly hydrolyzed in vivo to the corresponding thiophenol which in turn is further oxidized to the dimer and mixed disulfides (where the thiophenol binds to peptides, proteins and other endogenous thiols). These forms co-exist in an oxidation-reduction equilibrium via the thiol and cannot be stabilized without influencing the equilibrium, hence specific determination of individual components, i.e., in order to distinguish between the free thiol, the disulfide dimer and mixed disulfide adducts, was not pursued for routine analysis. The individual forms were quantified collectively as dalcetrapib-thiol (dal-thiol) after reduction under basic conditions with dithiothreitol to break disulfide bonds and derivatization with N-ethylmaleimide to stabilize the free thiol. The S-methyl and S-glucuronide metabolites were determined simultaneously with dal-thiol with no effect from the derivatization procedure. Column-switching liquid chromatography-tandem mass spectrometry provided a simple, fast and robust method for analysis of human and animal plasma and human urine samples. Addition of the surfactant Tween 80 to urine prevented adsorptive compound loss. The lower limits of quantitation (LLOQ) were 5 ng/mL for dal-thiol, and 5 ng/mL for the S-methyl and 50 ng/mL for the S-glucuronide metabolites. Using stable isotope-labeled internal standards, inter- and intra-assay precisions were each <15% (<20% at LLOQ) and accuracy was between 85 and 115%. Recovery was close to 100%, and no significant matrix effect was observed. PMID:22541249

  18. Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring

    PubMed Central

    Panuwet, Parinya; Hunter, Ronald E.; D’Souza, Priya E.; Chen, Xianyu; Radford, Samantha A.; Cohen, Jordan R.; Marder, M. Elizabeth; Kartavenka, Kostya; Ryan, P. Barry; Barr, Dana Boyd

    2015-01-01

    The ability to quantify levels of target analytes in biological samples accurately and precisely, in biomonitoring, involves the use of highly sensitive and selective instrumentation such as tandem mass spectrometers and a thorough understanding of highly variable matrix effects. Typically, matrix effects are caused by co-eluting matrix components that alter the ionization of target analytes as well as the chromatographic response of target analytes, leading to reduced or increased sensitivity of the analysis. Thus, before the desired accuracy and precision standards of laboratory data are achieved, these effects must be characterized and controlled. Here we present our review and observations of matrix effects encountered during the validation and implementation of tandem mass spectrometry-based analytical methods. We also provide systematic, comprehensive laboratory strategies needed to control challenges posed by matrix effects in order to ensure delivery of the most accurate data for biomonitoring studies assessing exposure to environmental toxicants. PMID:25562585

  19. Development of an advanced spacecraft tandem mass spectrometer

    NASA Technical Reports Server (NTRS)

    Drew, Russell C.

    1992-01-01

    The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology

  20. A high-throughput de novo sequencing approach for shotgun proteomics using high-resolution tandem mass spectrometry

    SciTech Connect

    Pan, Chongle; Park, Byung H; McDonald, W Hayes; Carey, Patricia A; Banfield, Jillian F.; Verberkmoes, Nathan C; Hettich, Robert {Bob} L; Samatova, Nagiza F

    2010-01-01

    Background High-resolution tandem mass spectra can now be readily acquired with hybrid instruments, such as LTQ-Orbitrap and LTQ-FT, in high-throughput shotgun proteomics workflows. The improved spectral quality enables more accurate de novo sequencing for identification of post-translational modifications and amino acid polymorphisms. Results In this study, a new de novo sequencing algorithm, called Vonode, has been developed specifically for analysis of such high-resolution tandem mass spectra. To fully exploit the high mass accuracy of these spectra, a unique scoring system is proposed to evaluate sequence tags based primarily on mass accuracy information of fragment ions. Consensus sequence tags were inferred for 11,422 spectra with an average peptide length of 5.5 residues from a total of 40,297 input spectra acquired in a 24-hour proteomics measurement of Rhodopseudomonas palustris. The accuracy of inferred consensus sequence tags was 84%. According to our comparison, the performance of Vonode was shown to be superior to the PepNovo v2.0 algorithm, in terms of the number of de novo sequenced spectra and the sequencing accuracy. Conclusions Here, we improved de novo sequencing performance by developing a new algorithm specifically for high-resolution tandem mass spectral data. The Vonode algorithm is freely available for download at http://compbio.ornl.gov/Vonode.

  1. LipidBlast - in-silico tandem mass spectrometry database for lipid identification

    PubMed Central

    Kind, Tobias; Liu, Kwang-Hyeon; Yup Lee, Do; DeFelice, Brian; Meissen, John K.; Fiehn, Oliver

    2013-01-01

    Current tandem mass spectral libraries for lipid annotations in metabolomics are limited in size and diversity. We provide a freely available computer generated in-silico tandem mass spectral library of 212,516 MS/MS spectra covering 119,200 compounds from 26 lipid compound classes, including phospholipids, glycerolipids, bacterial lipoglycans and plant glycolipids. Platform independence is shown by using tandem mass spectra from 40 different mass spectrometer types including low-resolution and high-resolution instruments. PMID:23817071

  2. Interpretation of tandem mass spectra obtained from cyclic nonribosomal peptides.

    PubMed

    Liu, Wei-Ting; Ng, Julio; Meluzzi, Dario; Bandeira, Nuno; Gutierrez, Marcelino; Simmons, Thomas L; Schultz, Andrew W; Linington, Roger G; Moore, Bradley S; Gerwick, William H; Pevzner, Pavel A; Dorrestein, Pieter C

    2009-06-01

    Natural and non-natural cyclic peptides are a crucial component in drug discovery programs because of their considerable pharmaceutical properties. Cyclosporin, microcystins, and nodularins are all notable pharmacologically important cyclic peptides. Because these biologically active peptides are often biosynthesized nonribosomally, they often contain nonstandard amino acids, thus increasing the complexity of the resulting tandem mass spectrometry data. In addition, because of the cyclic nature, the fragmentation patterns of many of these peptides showed much higher complexity when compared to related counterparts. Therefore, at the present time it is still difficult to annotate cyclic peptides MS/MS spectra. In this current work, an annotation program was developed for the annotation and characterization of tandem mass spectra obtained from cyclic peptides. This program, which we call MS-CPA is available as a web tool (http://lol.ucsd.edu/ms-cpa_v1/Input.py). Using this program, we have successfully annotated the sequence of representative cyclic peptides, such as seglitide, tyrothricin, desmethoxymajusculamide C, dudawalamide A, and cyclomarins, in a rapid manner and also were able to provide the first-pass structure evidence of a newly discovered natural product based on predicted sequence. This compound is not available in sufficient quantities for structural elucidation by other means such as NMR. In addition to the development of this cyclic annotation program, it was observed that some cyclic peptides fragmented in unexpected ways resulting in the scrambling of sequences. In summary, MS-CPA not only provides a platform for rapid confirmation and annotation of tandem mass spectrometry data obtained with cyclic peptides but also enables quantitative analysis of the ion intensities. This program facilitates cyclic peptide analysis, sequencing, and also acts as a useful tool to investigate the uncommon fragmentation phenomena of cyclic peptides and aids the

  3. Cloud parallel processing of tandem mass spectrometry based proteomics data.

    PubMed

    Mohammed, Yassene; Mostovenko, Ekaterina; Henneman, Alex A; Marissen, Rob J; Deelder, André M; Palmblad, Magnus

    2012-10-01

    Data analysis in mass spectrometry based proteomics struggles to keep pace with the advances in instrumentation and the increasing rate of data acquisition. Analyzing this data involves multiple steps requiring diverse software, using different algorithms and data formats. Speed and performance of the mass spectral search engines are continuously improving, although not necessarily as needed to face the challenges of acquired big data. Improving and parallelizing the search algorithms is one possibility; data decomposition presents another, simpler strategy for introducing parallelism. We describe a general method for parallelizing identification of tandem mass spectra using data decomposition that keeps the search engine intact and wraps the parallelization around it. We introduce two algorithms for decomposing mzXML files and recomposing resulting pepXML files. This makes the approach applicable to different search engines, including those relying on sequence databases and those searching spectral libraries. We use cloud computing to deliver the computational power and scientific workflow engines to interface and automate the different processing steps. We show how to leverage these technologies to achieve faster data analysis in proteomics and present three scientific workflows for parallel database as well as spectral library search using our data decomposition programs, X!Tandem and SpectraST.

  4. Ion-molecule adduct formation in tandem mass spectrometry.

    PubMed

    Alechaga, Élida; Moyano, Encarnación; Galceran, Maria Teresa

    2016-02-01

    Nowadays most LC-MS methods rely on tandem mass spectrometry not only for quantitation and confirmation of compounds by multiple reaction monitoring (MRM), but also for the identification of unknowns from their product ion spectra. However, gas-phase reactions between charged and neutral species inside the mass analyzer can occur, yielding product ions at m/z values higher than that of the precursor ion, or at m/z values difficult to explain by logical losses, which complicate mass spectral interpretation. In this work, the formation of adduct ions in the mass analyzer was studied using several mass spectrometers with different mass analyzers (ion trap, triple quadrupole, and quadrupole-Orbitrap). Heterocyclic amines (AαC, MeAαC, Trp-P-1, and Trp-P-2), photo-initiators (BP and THBP), and pharmaceuticals (phenacetin and levamisole) were selected as model compounds and infused in LCQ Classic, TSQ Quantum Ultra AM, and Q-Exactive Orbitrap (ThermoFisher Scientific) mass spectrometers using electrospray as ionization method. The generation of ion-molecule adducts depended on the compound and also on the instrument employed. Adducts with neutral organic solvents (methanol and acetonitrile) were only observed in the ion trap instrument (LCQ Classic), because of the ionization source on-axis configuration and the lack of gas-phase barriers, which allowed inertial entrance of the neutrals into the analyzer. Adduct formation (only with water) in the triple quadrupole instruments was less abundant than in the ion trap and quadrupole-Orbitrap mass spectrometers, because of the lower residence time of the reactive product ions in the mass analyzer. The moisture level of the CID and/or damper gas had a great effect in beam-like mass analyzers such as triple quadrupole, but not in trap-like mass analyzers, probably because of the long residence time that allowed adduct formation even with very low concentrations of water inside the mass spectrometer. PMID:26700446

  5. Non-target screening of veterinary drugs using tandem mass spectrometry on SmartMass.

    PubMed

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98% of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. PMID:23532781

  6. Non-Target Screening of Veterinary Drugs Using Tandem Mass Spectrometry on SmartMass

    NASA Astrophysics Data System (ADS)

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98 % of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. [Figure not available: see fulltext.

  7. Non-target screening of veterinary drugs using tandem mass spectrometry on SmartMass.

    PubMed

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98% of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules.

  8. Quantitative Comparison of Tandem Mass Spectra Obtained on Various Instruments

    NASA Astrophysics Data System (ADS)

    Bazsó, Fanni Laura; Ozohanics, Oliver; Schlosser, Gitta; Ludányi, Krisztina; Vékey, Károly; Drahos, László

    2016-08-01

    The similarity between two tandem mass spectra, which were measured on different instruments, was compared quantitatively using the similarity index (SI), defined as the dot product of the square root of peak intensities in the respective spectra. This function was found to be useful for comparing energy-dependent tandem mass spectra obtained on various instruments. Spectral comparisons show the similarity index in a 2D "heat map", indicating which collision energy combinations result in similar spectra, and how good this agreement is. The results and methodology can be used in the pharma industry to design experiments and equipment well suited for good reproducibility. We suggest that to get good long-term reproducibility, it is best to adjust the collision energy to yield a spectrum very similar to a reference spectrum. It is likely to yield better results than using the same tuning file, which, for example, does not take into account that contamination of the ion source due to extended use may influence instrument tuning. The methodology may be used to characterize energy dependence on various instrument types, to optimize instrumentation, and to study the influence or correlation between various experimental parameters.

  9. The application of tandem mass spectrometry to neonatal screening for inherited disorders of intermediary metabolism.

    PubMed

    Chace, Donald H; Kalas, Theodore A; Naylor, Edwin W

    2002-01-01

    This review is intended to serve as a practical guide for geneticists to current applications of tandem mass spectrometry to newborn screening. By making dried-blood spot analysis more sensitive, specific, reliable, and inclusive, tandem mass spectrometry has improved the newborn detection of inborn errors of metabolism. Its innate ability to detect and quantify multiple analytes from one prepared blood specimen in a single analysis permits broad recognition of amino acid, fatty acid, and organic acid disorders. An increasing number of newborn screening programs are either utilizing or conducting pilot studies with tandem mass spectrometry. It is therefore imperative that the genetics community be familiar with tandem mass spectrometric newborn screening.

  10. Radical-driven peptide backbone dissociation tandem mass spectrometry.

    PubMed

    Oh, Han Bin; Moon, Bongjin

    2015-01-01

    In recent years, a number of novel tandem mass spectrometry approaches utilizing radical-driven peptide gas-phase fragmentation chemistry have been developed. These approaches show a peptide fragmentation pattern quite different from that of collision-induced dissociation (CID). The peptide fragmentation features of these approaches share some in common with electron capture dissociation (ECD) or electron transfer dissociation (ETD) without the use of sophisticated equipment such as a Fourier-transform mass spectrometer. For example, Siu and coworkers showed that CID of transition metal (ligand)-peptide ternary complexes led to the formation of peptide radical ions through dissociative electron transfer (Chu et al., 2000. J Phys Chem B 104:3393-3397). The subsequent collisional activation of the generated radical ions resulted in a number of characteristic product ions, including a, c, x, z-type fragments and notable side-chain losses. Another example is the free radical initiated peptide sequencing (FRIPS) approach, in which Porter et al. and Beauchamp et al. independently introduced a free radical initiator to the primary amine group of the lysine side chain or N-terminus of peptides (Masterson et al., 2004. J Am Chem Soc 126:720-721; Hodyss et al., 2005 J Am Chem Soc 127: 12436-12437). Photodetachment of gaseous multiply charged peptide anions (Joly et al., 2008. J Am Chem Soc 130:13832-13833) and UV photodissociation of photolabile radical precursors including a C-I bond (Ly & Julian, 2008. J Am Chem Soc 130:351-358; Ly & Julian, 2009. J Am Soc Mass Spectrom 20:1148-1158) also provide another route to generate radical ions. In this review, we provide a brief summary of recent results obtained through the radical-driven peptide backbone dissociation tandem mass spectrometry approach.

  11. Exploiting the multiplexing capabilities of tandem mass tags for high-throughput estimation of cellular protein abundances by mass spectrometry.

    PubMed

    Ahrné, Erik; Martinez-Segura, Amalia; Syed, Afzal Pasha; Vina-Vilaseca, Arnau; Gruber, Andreas J; Marguerat, Samuel; Schmidt, Alexander

    2015-09-01

    The generation of dynamic models of biological processes critically depends on the determination of precise cellular concentrations of biomolecules. Measurements of system-wide absolute protein levels are particularly valuable information in systems biology. Recently, mass spectrometry based proteomics approaches have been developed to estimate protein concentrations on a proteome-wide scale. However, for very complex proteomes, fractionation steps are required, increasing samples number and instrument analysis time. As a result, the number of full proteomes that can be routinely analyzed is limited. Here we combined absolute quantification strategies with the multiplexing capabilities of isobaric tandem mass tags to determine cellular protein abundances in a high throughput and proteome-wide scale even for highly complex biological systems, such as a whole human cell line. We generated two independent data sets to demonstrate the power of the approach regarding sample throughput, dynamic range, quantitative precision and accuracy as well as proteome coverage in comparison to existing mass spectrometry based strategies.

  12. Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry

    PubMed Central

    Prokai, Laszlo; Stevens, Stanley M.

    2016-01-01

    Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass resolution was documented to be over 800,000 in full-scan MS mode and over 1,000,000 for an MS/MS product ion produced by collision-induced dissociation of the protonated analyte. Mass measurement accuracy below 1 ppm was obtained for all DART-generated ions that belonged to the test compound in the mass spectra acquired using only external mass calibration. This high mass measurement accuracy, achievable at present only through FTMS, was required for unequivocal identification of the corresponding molecular formulae. PMID:26784186

  13. Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry.

    PubMed

    Prokai, Laszlo; Stevens, Stanley M

    2016-01-01

    Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass resolution was documented to be over 800,000 in full-scan MS mode and over 1,000,000 for an MS/MS product ion produced by collision-induced dissociation of the protonated analyte. Mass measurement accuracy below 1 ppm was obtained for all DART-generated ions that belonged to the test compound in the mass spectra acquired using only external mass calibration. This high mass measurement accuracy, achievable at present only through FTMS, was required for unequivocal identification of the corresponding molecular formulae. PMID:26784186

  14. The Accuracy, Feasibility and Challenges of Sequencing Short Tandem Repeats Using Next-Generation Sequencing Platforms

    PubMed Central

    Zavodna, Monika; Bagshaw, Andrew; Brauning, Rudiger; Gemmell, Neil J.

    2014-01-01

    To date we have little knowledge of how accurate next-generation sequencing (NGS) technologies are in sequencing repetitive sequences beyond known limitations to accurately sequence homopolymers. Only a handful of previous reports have evaluated the potential of NGS for sequencing short tandem repeats (microsatellites) and no empirical study has compared and evaluated the performance of more than one NGS platform with the same dataset. Here we examined yeast microsatellite variants from both long-read (454-sequencing) and short-read (Illumina) NGS platforms and compared these to data derived through Sanger sequencing. In addition, we investigated any locus-specific biases and differences that might have resulted from variability in microsatellite repeat number, repeat motif or type of mutation. Out of 112 insertion/deletion variants identified among 45 microsatellite amplicons in our study, we found 87.5% agreement between the 454-platform and Sanger sequencing in frequency of variant detection after Benjamini-Hochberg correction for multiple tests. For a subset of 21 microsatellite amplicons derived from Illumina sequencing, the results of short-read platform were highly consistent with the other two platforms, with 100% agreement with 454-sequencing and 93.6% agreement with the Sanger method after Benjamini-Hochberg correction. We found that the microsatellite attributes copy number, repeat motif and type of mutation did not have a significant effect on differences seen between the sequencing platforms. We show that both long-read and short-read NGS platforms can be used to sequence short tandem repeats accurately, which makes it feasible to consider the use of these platforms in high-throughput genotyping. It appears the major requirement for achieving both high accuracy and rare variant detection in microsatellite genotyping is sufficient read depth coverage. This might be a challenge because each platform generates a consistent pattern of non-uniform sequence

  15. A tandem mass spectrometric method for singlet oxygen measurement.

    PubMed

    Karonen, Maarit; Mattila, Heta; Huang, Ping; Mamedov, Fikret; Styring, Stenbjörn; Tyystjärvi, Esa

    2014-01-01

    Singlet oxygen, a harmful reactive oxygen species, can be quantified with the substance 2,2,6,6-tetramethylpiperidine (TEMP) that reacts with singlet oxygen, forming a stable nitroxyl radical (TEMPO). TEMPO has earlier been quantified with electron paramagnetic resonance (EPR) spectroscopy. In this study, we designed an ultra-high-performance liquid chromatographic-tandem mass spectrometric (UHPLC-ESI-MS/MS) quantification method for TEMPO and showed that the method based on multiple reaction monitoring (MRM) can be used for the measurements of singlet oxygen from both nonbiological and biological samples. Results obtained with both UHPLC-ESI-MS/MS and EPR methods suggest that plant thylakoid membranes produce 3.7 × 10(-7) molecules of singlet oxygen per chlorophyll molecule in a second when illuminated with the photosynthetic photon flux density of 2000 μmol m(-2 ) s(-1). PMID:24849296

  16. Scandium analysis in silicon-containing minerals by inductively coupled plasma tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Whitty-Léveillé, Laurence; Drouin, Elisabeth; Constantin, Marc; Bazin, Claude; Larivière, Dominic

    2016-04-01

    This article reports on the development of a new method for the accurate and precise determination of the amount of scandium, Sc, in silicon-containing minerals, based on the use of tandem quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS). The tandem quadrupole instrument enables new mass filtering configurations, which can reduce polyatomic interferences during the determination of Sc in mineral matrices. He and O2 were used and compared as collision and reaction gases for the removal of interferences at m/z 45 and 61. Using helium gas was ineffective to overcome all of the spectral interferences observed at m/z 45 and particularly for Si-based interferences. However, conversion of Sc+ ions into ScO+ ions (after bombardment with O2 in the octopole reaction system coupled with the use of the instrument in MS/MS mass-shift mode) provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L- 1, to accurately detect Sc. The accuracy of the proposed methodology was assessed by analyzing five different reference materials (BX-N, OKA-2, NIM-L, SY-3 and GH).

  17. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    ERIC Educational Resources Information Center

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  18. Determination of intact oxaliplatin in human plasma using high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Wenjiang; Seymour, Lesley; Chen, Eric X

    2008-12-15

    A HPLC-tandem mass spectrometry method was developed and validated for the quantitation of intact oxaliplatin in human plasma. Plasma ultrafiltrates were precipitated with acetonitrile and separation was performed on a 250 mm Beckman ODS reverse phase column using a gradient mobile phase. The mass spectrometer was operated in positive ionization mode using TurboionSpray and precursor-product ion combinations of m/z 391.1-->305.1 and 371.1-->247.0 were monitored for oxaliplatin and carboplatin, the internal standard, respectively. The lower limit of quantitation for oxaliplatin was 20 ng/ml. The linear range of the method was 20-1000 ng/ml. The between- and within-day relative standard deviations ranged from 3.1 to 7.7%, and accuracy was within 5%. This method was successfully applied in a clinical study of oxaliplatin.

  19. Fast atom bombardment tandem mass spectrometry of carotenoids

    SciTech Connect

    van Breeman, R.B.; Schmitz, H.H.; Schwartz, S.J.

    1995-02-01

    Positive ion fast atom bombardment (FAB) tandem mass spectrometry (MS-MS) using a double-focusing mass spectrometer with linked scanning at constant B/E and high-energy collisionally activated dissociation (CAD) was used to differentiate 17 different cartenoids, including {beta}-apo-8{prime}- carotenal, astaxanthin, {alpha}-carotene, {beta}-carotene, {gamma}-carotene, {zeta}-carotene, canthaxanthin, {beta}-cryptoxanthin, isozeaxanthin bis (pelargonate), neoxanthin, neurosporene, nonaprene, lutein, lycopene, phytoene, phytofluene, and zeaxanthin. The carotenoids were either synthetic or isolated from plant tissues. The use of FAB ionization minimized degradation or rearrangement of the carotenoid structures due to the inherent thermal instability generally ascribed to these compounds. Instead of protonated molecules, both polar xanthophylls and nonpolar carotenes formed molecular ions, M{sup {center_dot}+}, during FAB ionization. Following collisionally activated dissociation, fragment ions of selected molecular ion precursors showed structural features indicative of the presence of hydroxyl groups, ring systems, ester groups, and aldehyde groups and the extent of aliphatic polyene conjugation. The fragmentation patterns observed in the mass spectra herein may be used as a reference for the structural determination of carotenoids isolated from plant and animal tissues. 18 refs., 4 figs.

  20. iPE-MMR: An integrated approach to accurately assign monoisotopic precursor masses to tandem mass spectrometric data

    PubMed Central

    Jung, Hee-Jung; Purvine, Samuel O.; Kim, Hokeun; Petyuk, Vladislav A.; Hyung, Seok-Won; Monroe, Matthew E.; Mun, Dong-Gi; Kim, Kyong-Chul; Park, Jong-Moon; Kim, Su-Jin; Tolic, Nikola; Slysz, Gordon W.; Moore, Ronald J.; Zhao, Rui; Adkins, Joshua N.; Anderson, Gordon A.; Lee, Hookeun; Camp, David G.; Yu, Myeong-Hee; Smith, Richard D.; Lee, Sang-Won

    2010-01-01

    Accurate assignment of monoisotopic precursor masses to tandem mass spectrometric (MS/MS) data is a fundamental and critically important step for successful peptide identifications in mass spectrometry based proteomics. Here we describe an integrated approach that combines three previously reported methods of treating MS/MS data for precursor mass refinement. This combined method, “integrated Post-Experiment Monoisotopic Mass Refinement” (iPE-MMR), integrates steps: 1) generation of refined MS/MS data by DeconMSn; 2) additional refinement of the resultant MS/MS data by a modified version of PE-MMR; 3) elimination of systematic errors of precursor masses using DtaRefinery. iPE-MMR is the first method that utilizes all MS information from multiple MS scans of a precursor ion including multiple charge states, in an MS scan, to determine precursor mass. By combining these methods, iPE-MMR increases sensitivity in peptide identification and provides increased accuracy when applied to complex high-throughput proteomics data. PMID:20863060

  1. Probabilistic consensus scoring improves tandem mass spectrometry peptide identification.

    PubMed

    Nahnsen, Sven; Bertsch, Andreas; Rahnenführer, Jörg; Nordheim, Alfred; Kohlbacher, Oliver

    2011-08-01

    Database search is a standard technique for identifying peptides from their tandem mass spectra. To increase the number of correctly identified peptides, we suggest a probabilistic framework that allows the combination of scores from different search engines into a joint consensus score. Central to the approach is a novel method to estimate scores for peptides not found by an individual search engine. This approach allows the estimation of p-values for each candidate peptide and their combination across all search engines. The consensus approach works better than any single search engine across all different instrument types considered in this study. Improvements vary strongly from platform to platform and from search engine to search engine. Compared to the industry standard MASCOT, our approach can identify up to 60% more peptides. The software for consensus predictions is implemented in C++ as part of OpenMS, a software framework for mass spectrometry. The source code is available in the current development version of OpenMS and can easily be used as a command line application or via a graphical pipeline designer TOPPAS.

  2. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    PubMed

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202).

  3. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    PubMed

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). PMID:27154569

  4. PepArML: A Meta-Search Peptide Identification Platform for Tandem Mass Spectra.

    PubMed

    Edwards, Nathan J

    2013-12-01

    The PepArML meta-search peptide identification platform for tandem mass spectra provides a unified search interface to seven search engines; a robust cluster, grid, and cloud computing scheduler for large-scale searches; and an unsupervised, model-free, machine-learning-based result combiner, which selects the best peptide identification for each spectrum, estimates false-discovery rates, and outputs pepXML format identifications. The meta-search platform supports Mascot; Tandem with native, k-score and s-score scoring; OMSSA; MyriMatch; and InsPecT with MS-GF spectral probability scores—reformatting spectral data and constructing search configurations for each search engine on the fly. The combiner selects the best peptide identification for each spectrum based on search engine results and features that model enzymatic digestion, retention time, precursor isotope clusters, mass accuracy, and proteotypic peptide properties, requiring no prior knowledge of feature utility or weighting. The PepArML meta-search peptide identification platform often identifies two to three times more spectra than individual search engines at 10% FDR.

  5. Quantitative and confirmative performance of liquid chromatography coupled to high-resolution mass spectrometry compared to tandem mass spectrometry.

    PubMed

    Kaufmann, Anton; Butcher, Patrick; Maden, Kathryn; Walker, Stephan; Widmer, Miryam

    2011-04-15

    The quantitative and confirmative performance of two different mass spectrometry (MS) techniques (high-resolution MS and tandem MS) was critically compared. Evaluated was a new extraction and clean-up protocol which was developed to cover more than 100 different veterinary drugs at trace levels in a number of animal tissues and honey matrices. Both detection techniques, high-resolution mass spectrometry (HRMS) (single-stage Orbitrap instrument operated at 50 000 full width at half maximum) and tandem mass spectrometry (MS/MS) (quadrupole technology) were used to validate the method according to the EU Commission Decision 2002/657/EEC. Equal or even a slightly better quantitative performance was observed for the HRMS-based approach. Sensitivity is higher for unit mass resolution MS/MS if only a subset of the 100 compounds has to be monitored. Confirmation of suspected positive findings can be done by evaluating the intensity ratio between different MS/MS transitions, or by accurate mass based product ion traces (no precursor selection applied). MS/MS relies on compound-specific optimized transitions; hence the second, confirmatory transition generally shows relatively high ion abundance (fragmentation efficacy). This is often not the case in single-stage HRMS, since a generic (not compound-optimized) collision energy is applied. Hence, confirmation of analytes present at low levels is superior when performed by MS/MS. Slightly better precision, but poorer accuracy (fortified matrix extracts versus pure standard solution) of ion ratios were observed when comparing data obtained by HRMS versus MS/MS. PMID:21416536

  6. An evaluation of tandem mass spectrometry in drug metabolism studies.

    PubMed

    Naylor, S; Kajbaf, M; Lamb, J H; Jahanshahi, M; Gorrod, J W

    1993-07-01

    The use of precursor ion and constant neutral loss scanning as a means of rapidly detecting drug metabolites is evaluated. Four clinically useful drugs, namely (i) cyclophosphamide, (ii) mifentidine, (iii) cimetropium bromide and (iv) haloperidol, were subjected to microsomal incubations to afford phase I metabolites. Aside from a minor clean-up procedure involving zinc sulfate precipitation of microsomal proteins and solid-phase extraction of metabolites using a Sep-pak C-18 cartridge, the mixtures were analysed directly by fast atom bombardment tandem mass spectrometry. It is demonstrated that such screening strategies are important in detecting novel metabolites. However, there are some problems associated with only using such methods, including (i) the possibility of not detecting metabolites that undergo unusual collision-induced dissociation fragmentation pathways, (ii) the non-detection of metabolites that have undergone metabolic change at unusual sites of reactivity, and (iii) production of artifacts derived from the parent drug by the primary ionization process. Examples are discussed that highlight both the strengths and weaknesses of such an approach.

  7. Confirmatory analysis of firocoxib in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    PubMed

    Dowling, Geraldine; Gallo, Pasquale; Regan, Liam

    2009-02-15

    A rapid method has been developed to analyse for firocoxib (FIRO) residue in bovine milk. Milk samples were extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS). The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 1.18ng/mL and for the detection capability a (CCbeta) value of 2.02ng/mL was obtained. The measurement uncertainty of the method was 27%. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 96 and 105%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10ng/mL) was less than 11% respectively.

  8. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry.

    PubMed

    Bornø, Andreas; Foged, Lene; van Hall, Gerrit

    2014-10-01

    The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-(13) C(6)]glucose and [U-(13) C(6), D(7)]glucose, and for glycerol, [U-(13) C(3), D(8)]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6-D(2)]glucose, [U-(13) C(6)]glucose, and [1,1,2,3,3-D(5)]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze-thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r(2) = 0.9998 for [U-(13) C(6)]glucose and r(2) = 0.9996 for [U-(13) C(6), D(7)]glucose, and r(2) = 0.9995 for the glycerol concentration. Interday accuracy for glucose using [U-(13) C(6)]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies.

  9. A high-throughput de novo sequencing approach for shotgun proteomics using high-resolution tandem mass spectrometry

    SciTech Connect

    Pan, Chongle; Park, Byung H; McDonald, W Hayes; Banfield, Jillian F.; Verberkmoes, Nathan C; Hettich, Robert {Bob} L; Samatova, Nagiza F

    2010-01-01

    High-resolution tandem mass spectra can now readily be acquired with hybrid instruments, such as LTQ-Orbitrap and LTQ-FT, in high-throughput shotgun proteomics workflows. In this study, a new de novo sequencing algorithm, Vonode, has been developed specifically for such high-resolution tandem mass spectra. To fully exploit the high mass accuracy, sparse noise, and low background of these spectra, a unique scoring system is used to evaluate sequence tags based mainly on mass accuracy information of fragment ions. Consensus sequence tags were inferred for 11,422 spectra with an average peptide length of 5.5 residues from a total of 40,297 input spectra acquired in a 24-hour proteomics measurement of Rhodopseudomonas palustris. The accuracy of inferred consensus sequence tags was 84%. The performance of Vonode was shown to be superior to the PepNovo v2.0 algorithm, especially in term of the number of de novo sequenced spectra.

  10. Revisiting hyper- and hypo-androgenism by tandem mass spectrometry.

    PubMed

    Fanelli, Flaminia; Gambineri, Alessandra; Mezzullo, Marco; Vicennati, Valentina; Pelusi, Carla; Pasquali, Renato; Pagotto, Uberto

    2013-06-01

    Modern endocrinology is living a critical age of transition as far as laboratory testing and biochemical diagnosis are concerned. Novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for steroid measurement in biological fluids have abundantly demonstrated their analytical superiority over immunometric platforms that until now have dominated the world of steroid hormones determination in clinical laboratories. One of the most useful applications of LC-MS/MS is in the hypogonadism and hyperandrogenism field: LC-MS/MS has proved particularly suitable for the detection of low levels of testosterone typical of women and children, and in general more reliable in accurately determining hypogonadal male levels. This technique also offers increased informative power by allowing multi-analytical profiles that give a more comprehensive picture of the overall hormonal asset. Several LC-MS/MS methods for testosterone have been published in the last decade, some of them included other androgen or more comprehensive steroid profiles. LC-MS/MS offers the concrete possibility of achieving a definitive standardization of testosterone measurements and the generation of widely accepted reference intervals, that will set the basis for a consensus on the diagnostic value of biochemical testing. The present review is aimed at summarizing technological advancements in androgen measurements in serum and saliva. We also provide a picture of the state of advancement of standardization of testosterone assays, of the redefinition of androgen reference intervals by novel assays and of studies using LC-MS/MS for the characterization and diagnosis of female hyperandrogenism and male hypogonadism.

  11. Accurate mass determination of short-lived isotopes by a tandem Penning-trap mass spectrometer

    SciTech Connect

    Stolzenberg, H.; Becker, S.; Bollen, G.; Kern, F.; Kluge, H.; Otto, T.; Savard, G.; Schweikhard, L. ); Audi, G. ); Moore, R.B. ); The ISOLDE Collaboration

    1990-12-17

    A mass spectrometer consisting of two Penning traps has been set up for short-lived isotopes at the on-line mass separator ISOLDE at CERN. The ion beam is collected and cooled in the first trap. After delivery to the second trap, high-accuracy direct mass measurements are made by determining the cyclotron frequency of the stored ions. Measurements have been performed for {sup 118}Cs--{sup 137}Cs. A resolving power of over 10{sup 6} and an accuracy of 1.4{times}10{sup {minus}7} have been achieved, corresponding to about 20 keV.

  12. 10 K Ring Electrode Trap - Tandem Mass Spectrometer for Infrared Spectroscopy of Mass Selected Ions

    SciTech Connect

    Goebbert, Daniel J.; Meijer, Gerard; Asmis, Knut R.

    2009-03-17

    A novel instrumental setup for measuring infrared photodissociation spectra of buffer gas cooled, mass-selected ions is described and tested. It combines a cryogenically cooled, linear radio frequency ion trap with a tandem mass spectrometer, optimally coupling continuous ion sources to pulsed laser experiments. The use of six independently adjustable DC potentials superimposed over the trapping radio frequency field provides control over the ion distribution within, as well as the kinetic energy distribution of the ions extracted from the ion trap. The scheme allows focusing the ions in space and time, such that they can be optimally irradiated by a pulsed, widely tunable infrared photodissociation laser. Ion intensities are monitored with a time-of-flight mass spectrometer mounted orthogonally to the ion trap axis.

  13. High-accuracy mass spectrometry for fundamental studies.

    PubMed

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions.

  14. High-accuracy mass spectrometry for fundamental studies.

    PubMed

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions. PMID:20530821

  15. Determination of perchlorate in infant formula by isotope dilution ion chromatography/tandem mass spectrometry

    PubMed Central

    Wang, Z.; Lau, B.P.-Y.; Tague, B.; Sparling, M.; Forsyth, D.

    2011-01-01

    A sensitive and selective isotope dilution ion chromatography/tandem mass spectrometry (ID IC-MS/MS) method was developed and validated for the determination of perchlorate in infant formula. The perchlorate was extracted from infant formula by using 20 ml of methanol and 5 ml of 1% acetic acid. All samples were spiked with 18O4 isotope-labelled perchlorate internal standard prior to extraction. After purification on a graphitised carbon solid-phase extraction column, the extracts were injected into an ion chromatography system equipped with an Ionpac AS20 column for separation of perchlorate from other anions. The presence of perchlorate in samples was quantified by isotope dilution mass spectrometry. Analysis of both perchlorate and its isotope-labelled internal standard was carried out on a Waters Quattro Ultima triple quadrupole mass spectrometer operating in a multiple reaction monitoring (MRM) negative ionisation mode. The method was validated for linearity and range, accuracy, precision, sensitivity, and matrix effects. The limit of quantification (LOQ) was 0.4 μg 1−1 for liquid infant formula and 0.95 μg kg−1 for powdered infant formula. The recovery ranged from 94% to 110% with an average of 98%. This method was used to analyse 39 infant formula, and perchlorate concentrations ranging from

  16. Tandem Mass Spectrometry of Bilin Tetrapyrroles by Electrospray Ionization and Collision Induced Dissociation

    PubMed Central

    Quinn, Kevin D.; Nguyen, Nhu Q. T.; Wach, Michael M.; Wood, Troy D.

    2012-01-01

    Rationale Bilins are metabolic products of hosts and bacteria on porphyrins, and are markers of health state and human waste contamination. Although bilin tandem mass spectrometry reports exist, their fragmentation behavior as a function of structure has not been compared, nor has fragmentation been examined as a function of collision energy. Methods: The fragmentation of bilins generated by positive ion mode electrospray ionization is examined by collision induced dissociation (CID). CID on a quadrupole ion trap and on a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer as a function of collision energy is compared. Methyl esterification was used to deduce which product ions contain the inner pyrrole rings. FT-ICR high mass accuracy measurements were used to determine the formulas of the resultant product ions. Results The central carbon’s bonding to the inner pyrrole rings influences fragmentation. Bilirubin is unique because fragmentation adjacent to the central methylene group between innermost rings predominates, and loss of a terminal pyrrole is observed only with helium collision gas. The other bilins lose the terminal pyrroles first; as CID energy is increased, additional fragmentation due to neutral losses of small molecules such as H2O, CO, CO2, and methanol occurs. Conclusions Based on these observations, fragmentation schemes for the bilins are proposed that are strongly dependent on the molecular structure and collision energy; only bilirubin fragmentation is influenced significantly by the collision gas used. This report should have value in identification of this class of molecules for biomarker detection. PMID:22777778

  17. Ultra-high-pressure liquid chromatography-tandem mass spectrometry method for the determination of alkylphenols in soil.

    PubMed

    Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei

    2009-03-20

    A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.

  18. Integrated Post-Experiment Monoisotopic Mass Refinement: An Integrated Approach to Accurately Assign Monoisotopic Precursor Masses to Tandem Mass Spectrometric Data

    SciTech Connect

    Jung, Hee-Jung; Purvine, Samuel O.; Kim, Hokeun; Petyuk, Vladislav A.; Hyung, Seok-Won; Monroe, Matthew E.; Mun, Dong-Gi; Kim, Kyong-Chul; Park, Jong-Moon; Kim, Su-Jin; Tolic, Nikola; Slysz, Gordon W.; Moore, Ronald J.; Zhao, Rui; Adkins, Joshua N.; Anderson, Gordon A.; Lee, Hookeun; Camp, David G.; Yu, Myeong-Hee; Smith, Richard D.; Lee, Sang-Won

    2010-10-15

    Accurate assignment of monoisotopic precursor masses to tandem mass spectrometric (MS/MS) data is a fundamental and critically important step for successful peptide identifications in mass spectrometry based proteomics. Here we describe an integrated approach that combines three previously reported methods of treating MS/MS data for precursor mass refinement. This combined method, “integrated Post-Experiment Monoisotopic Mass Refinement” (iPE MMR), integrates steps: 1) generation of refined MS/MS data by DeconMSn, 2) additional refinement of the resultant MS/MS data by a modified version of PE-MMR, and 3) elimination of systematic errors of precursor masses using DtaRefinery. iPE-MMR is the first method that utilizes all MS information from multiple MS scans of a precursor ion and multiple charge states of it in an MS scan to determine precursor mass. By combining the synergistic features of each of method, iPE MMR increases sensitivity in peptide identification and provides increased accuracy when applied to complex high-throughput proteomics data. iPE MMR also allows incorporating additional data processing step(s) or skipping step(s), if necessary, to enable new developments or applications of the tools, as each step of iPE MMR produces output data in a common and conventional format used in proteomics data processing.

  19. Measurement of hydroxysafflor yellow A in human urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Chang-Yin; Chu, Ji-Hong; Zhang, Jun; Sun, Bing-Ting; Dai, Guo-Liang; Liu, Shi-Jia; Ju, Wen-Zheng

    2015-01-01

    A rapid and specific high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the quantification of hydroxysafflor yellow A (HSYA) in human urine with isorhamnetin-3-O-neohespeidoside as internal standard (IS). HSYA and IS were extracted from urine samples by simple solid-phase extraction and separated on an Agilent Zorbax SB C18 column (4.6 mm × 150 mm, 5 μm) with the mobile phase of 0.2 mM ammonium acetate: methanol (30/70, v/v) at a flow rate of 0.4 mL/min. Polar endogenous interferences eluted in 0.1-2.5 min were switched into waste channel by the Valve Valco, to reduce the possible matrix effect for MS detection in each run. The MS detection of analytes was performed on a tandem mass spectrometer equipped with an electrospray ionization source in negative mode using multiple-reaction monitoring. The MS/MS ion transitions monitored were m/z 611.3→491.2 for HSYA and m/z 623.2→299.2 for IS. The method was fully validated for selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability, and then was applied to the urinary excretion study of injectable powder of pure HSYA in healthy Chinese volunteers for the first time. The results suggested that urine was the main excretion way of HSYA in healthy volunteers, further demonstrating the feasibility and necessity of our current method. PMID:25463208

  20. Confirmation and quantification of clenbuterol in horse urine using liquid chromatography tandem mass spectrometry triple quadrupole.

    PubMed

    Bishop, Jennifer; Heffron, Brendan; Taddei, Lisa; Benoit, Marc; Hurt, Laura; Costello, Sara; Gross, Melissa; Negrusz, Adam

    2015-03-01

    Clenbuterol (CLE) is used in horses as a bronchodilator and for its anabolic steroid-like effects. CLE is a Class 3 drug according to current Association of Racing Commissioners International (ARCI) Uniform Classification Guidelines. The Racing Medication and Testing Consortium recommended a urine CLE threshold of 140 pg/mL after careful scientific review of the results of studies describing the disposition of CLE in the horse and this threshold was adopted by the ARCI. Enzyme-linked immunosorbent assay was previously used to screen samples for CLE in Illinois, but could not detect such low concentrations in urine. Thus, a liquid-liquid extraction of CLE from urine followed by quantification by liquid chromatography-tandem mass spectrometry was developed and validated. Method validation included testing stability, ion suppression and enhancement, precision, accuracy and uncertainty. Intra-, interday and total precision and accuracy were calculated for each control and found to be within the ±15% acceptance range. The Guide to the Expression of Uncertainty in Measurement approach was used to calculate uncertainty, which was 11% at the 95% confidence level. In the past 5 years, only 15 samples were reported as positive for CLE in Illinois. This new method was used in a pilot program to screen and confirm samples received from thoroughbred and harness horses.

  1. Determination and pharmacokinetic studies of arecoline in dog plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Bing; Zhou, Xu-Zheng; Li, Jian-Yong; Yang, Ya-Jun; Niu, Jian-Rong; Wei, Xiao-Juan; Liu, Xi-Wang; Li, Jin-Shan; Zhang, Ji-Yu

    2014-10-15

    A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of arecoline concentration in dog plasma. Plasma sample was prepared by protein precipitation using n-hexane (containing 1% isoamyl alcohol) with β-pinene as an internal standard. Chromatographic separation was achieved on an Agilent C18 column (4.6×75mm, 3.5μm) using methanol: 5mM ammonium acetate as the mobile phase with isocratic elution. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve for arecoline was linear over a concentration range of 2-500ng/mL. The intra-day and inter-day accuracy and precision were within the acceptable limits of ±10% at all concentrations. In summary, the LC-MS/MS method described herein was fully validated and successfully applied to the pharmacokinetic study of arecoline hydrobromide tablets in dogs after oral administration. PMID:25140901

  2. Determination of faropenem in human plasma and urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Gao, Shouhong; Chen, Wansheng; Tao, Xia; Miao, Haijun; Yang, Shaolin; Wu, Rong

    2008-01-01

    A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry (LC-MS/MS) quantitative detection method, using cefalexin as internal standard, was developed for the analysis of faropenem in human plasma and urine. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a C18 reversed-phase column with 0.1% formic acid-methanol (45:55, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves with good linearities (r=0.9991 for plasma sample and r=0.9993 for urine sample) were obtained in the range 5-4000 ng/mL for faropenem. The limit of detection was 5 ng/mL. Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of faropenem in humans, and to our knowledge, it is the first time the pharmacokinetic of faropenem has been elucidated in vivo using LC-MS/MS. PMID:17604362

  3. Dynamic Bayesian Network for Accurate Detection of Peptides from Tandem Mass Spectra.

    PubMed

    Halloran, John T; Bilmes, Jeff A; Noble, William S

    2016-08-01

    A central problem in mass spectrometry analysis involves identifying, for each observed tandem mass spectrum, the corresponding generating peptide. We present a dynamic Bayesian network (DBN) toolkit that addresses this problem by using a machine learning approach. At the heart of this toolkit is a DBN for Rapid Identification (DRIP), which can be trained from collections of high-confidence peptide-spectrum matches (PSMs). DRIP's score function considers fragment ion matches using Gaussians rather than fixed fragment-ion tolerances and also finds the optimal alignment between the theoretical and observed spectrum by considering all possible alignments, up to a threshold that is controlled using a beam-pruning algorithm. This function not only yields state-of-the art database search accuracy but also can be used to generate features that significantly boost the performance of the Percolator postprocessor. The DRIP software is built upon a general purpose DBN toolkit (GMTK), thereby allowing a wide variety of options for user-specific inference tasks as well as facilitating easy modifications to the DRIP model in future work. DRIP is implemented in Python and C++ and is available under Apache license at http://melodi-lab.github.io/dripToolkit .

  4. Dynamic Bayesian Network for Accurate Detection of Peptides from Tandem Mass Spectra.

    PubMed

    Halloran, John T; Bilmes, Jeff A; Noble, William S

    2016-08-01

    A central problem in mass spectrometry analysis involves identifying, for each observed tandem mass spectrum, the corresponding generating peptide. We present a dynamic Bayesian network (DBN) toolkit that addresses this problem by using a machine learning approach. At the heart of this toolkit is a DBN for Rapid Identification (DRIP), which can be trained from collections of high-confidence peptide-spectrum matches (PSMs). DRIP's score function considers fragment ion matches using Gaussians rather than fixed fragment-ion tolerances and also finds the optimal alignment between the theoretical and observed spectrum by considering all possible alignments, up to a threshold that is controlled using a beam-pruning algorithm. This function not only yields state-of-the art database search accuracy but also can be used to generate features that significantly boost the performance of the Percolator postprocessor. The DRIP software is built upon a general purpose DBN toolkit (GMTK), thereby allowing a wide variety of options for user-specific inference tasks as well as facilitating easy modifications to the DRIP model in future work. DRIP is implemented in Python and C++ and is available under Apache license at http://melodi-lab.github.io/dripToolkit . PMID:27397138

  5. Tandem mass spectrometry in food safety assessment: the determination of phthalates in olive oil.

    PubMed

    Cavaliere, Brunella; Macchione, Barbara; Sindona, Giovanni; Tagarelli, Antonio

    2008-09-26

    A gas chromatography-tandem mass spectrometry (GC-MS/MS) method for the detection of six phthalates in olive oil was developed. A gel permeation chromatography (GPC) clean-up step with cyclohexane:dichoromethane 7:3 as mobile phase was employed to remove the high-molecular mass species present in oil. Two ionization methodologies, i.e. electron (EI) and isobutane-chemical ionization (CI), were compared, in MS/MS mode, to achieve better analytical performances. An overall evaluation of all analytical parameters shows that the EI-MS/MS approach provides satisfactory results and is to be preferred to CI-MS/MS, at least in the case of the examined analytes. The observed accuracies, ranging from 71.7% to 112.2%, and the RSD values less than 9.7%, confirm the effectiveness of the proposed method in the assay of phthalate content in such a complex matrix as olive oil. The proposed protocol for the identification and assay of phthalates in olive oil might be of interest for the implementation of the QS (quality assurance scheme) for residue monitoring in food safety assessment.

  6. ANALYSIS OF POLYCYCLIC AROMATIC HYDROCARBONS BY ION TRAP TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    An ion-trap mass spectrometer with a wave board and tandem mass spectrometry software was used to analyze gas chromatographically separated polycyclic aromatic hydrocarbons (PAHs) by using collision-induced dissociation (CID). The nonresonant (multiple collision) mode was used to...

  7. High-Speed Tandem Mass Spectrometric in Situ Imaging by Nanospray Desorption Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Lanekoff, Ingela T.; Burnum-Johnson, Kristin E.; Thomas, Mathew; Short, Joshua TL; Carson, James P.; Cha, Jeeyeon; Dey, Sudhansu K.; Yang, Pengxiang; Prieto Conaway, Maria C.; Laskin, Julia

    2013-10-15

    Nanospray desorption electrospray ionization (nano-DESI) combined with tandem mass spectrometry (MS/MS), high-resolution mass analysis (m/m=17,500 at m/z 200), and rapid spectral acquisition enabled simultaneous imaging and identification of more than 300 molecules from 92 selected m/z windows (± 1 Da) with a spatial resolution of better than 150 um. Uterine sections of implantation sites on day 6 of pregnancy were analyzed in the ambient environment without any sample pre-treatment. MS/MS imaging was performed by scanning the sample under the nano-DESI probe at 10 um/s while acquiring higher-energy collision-induced dissociation (HCD) spectra for a targeted inclusion list of 92 m/z values at a rate of ~6.3 spectra/s. Molecular ions and their corresponding fragments, separated using high-resolution mass analysis, were assigned based on accurate mass measurement. Using this approach, we were able to identify and image both abundant and low-abundance isobaric species within each m/z window. MS/MS analysis enabled efficient separation and identification of isobaric sodium and potassium adducts of phospholipids. Furthermore, we identified several metabolites associated with early pregnancy and obtained the first 2D images of these molecules.

  8. Determination of loperamide in human plasma and saliva by liquid chromatography-tandem mass spectrometry.

    PubMed

    Arafat, Tawfiq; Arafat, Basil; awad, Riad; awwad, Ahmad Abu

    2014-12-01

    A simple and sensitive liquid chromatography-tandem mass spectrometric method for quantification of loperamide in human plasma and saliva was developed and validated, and then successfully applied in pharmacokinetic clinical study to investigate and correlate bioavailability of Imodium(®) 2mg quartet tablet dose in both human plasma and saliva. Loperamide with labeled internal standard was extracted from its biological matrix by methanol as protein direct precipitant in single extraction step. Adequate chromatographic separation for analytes from plasma and saliva matrices was achieved using ACE C18 (50mm×2.1mm, 5μm) column, eluted by water/methanol/formic acid (30:70:0.1%, v/v), delivered isocratically at constant flow rate of 0.75ml/min. The method validation intends to investigate specificity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability according to European guideline, and partial validation was applied on saliva, specificity, matrix effect, recovery, sensitivity, within and between day precision and accuracy. The calibration curve was linear through the range of 20-3000pg/ml in both plasma and saliva using a 50μl sample volume. The partial validation sections outcome in saliva was so close to those in plasma. The within- and between-day precisions were all below 8.7% for plasma and below 11.4% for saliva. Accuracies ranged from 94 to 105% for both matrices. In this study, 26 healthy volunteers participated in the clinical study, and 6 of gave their saliva samples in addition to plasma at the same time schedule. The pharmacokinetic parameters of Cmax, AUC0-t and AUC0-∞, Tmax and T1/2 in both plasma and saliva were calculated and correlated.

  9. Determination of low-level acrylamide in drinking water by liquid chromatography/tandem mass spectrometry.

    PubMed

    Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara

    2009-01-01

    A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation <7.98%. Performance characteristics of this LC/MS/MS method make it suitable for regulatory confirmatory analysis of AA in drinking water in compliance with European Union and U.S. Environmental Protection Agency standards.

  10. Liquid chromatography-mass spectrometric and liquid chromatography-tandem mass spectrometric determination of hallucinogenic indoles psilocin and psilocybin in "magic mushroom" samples.

    PubMed

    Kamata, Tooru; Nishikawa, Mayumi; Katagi, Munehiro; Tsuchihashi, Hitoshi

    2005-03-01

    Accurate and sensitive analytical methods for psilocin (PC) and psilocybin (PB), tryptamine-type hallucinogens contained in "magic mushrooms," were investigated using liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The chromatographic separation on an ODS column and mass spectral information gave complete discrimination between PC and PB without derivatization. The mass spectrometric detection had a high sensitivity, and the tandem mass spectrometric detection provided more specificity and accuracy, as well as high sensitivity. The detection limits ranged from 1 to 25 pg by LC-MS in the selected ion monitoring mode, and the intra- and inter-day coefficients of variation were estimated to be 4.21-5.93% by LC-MS-MS in the selected reaction monitoring mode. By applying the present LC-MS-MS technique to four real samples, the contents of PC and PB were found to vary over a wide range (0.60-1.4 and 0.18-3.8 mg/g dry wt. for PC and PB, respectively) between samples.

  11. High explosives vapor detection by atmospheric sampling glow discharge ionization/tandem mass spectrometry

    SciTech Connect

    McLuckey, S.A.; Goeringer, D.E.; Asano, K.G.

    1996-02-01

    The combination of atmospheric sampling glow discharge ionization with tandem mass spectrometry for the detection of traces of high explosives is described. Particular emphasis is placed on use of the quadrupole ion trap as the type of tandem mass spectrometer. Atmospheric sampling glow discharge provides a simple, rugged, and efficient means for anion formation while the quadrupole ion trap provides for efficient tandem mass spectrometry. Mass selective ion accumulation and non-specific ion activation methods can be used to overcome deleterious effects arising from ion/ion interactions. Such interactions constitute the major potential technical barrier to the use of the ion trap for real-time monitoring of targeted compounds in uncontrolled and highly variable matrices. Tailored waveforms can be used to effect both mass selective ion accumulation and ion activation. Concatenated tailored waveforms allow for both functions in a single experiment thereby providing the capability for monitoring several targeted species simultaneously. The combination of atmospheric sampling glow discharge ionization with a state-of-the-art analytical quadrupole ion trap is a highly sensitive and specific detector for traces of high explosives. The combination is also small and inexpensive relative to virtually any other form of tandem mass spectrometry. The science and technology underlying the glow discharge/ion trap combination is sufficiently mature to form the basis for an engineering effort to make the detector portable. 85 refs.

  12. Application of matrix calculation 1: Design and adjustment of a tandem mass spectrometer for Collision-Activated Dissociation (CAD)

    NASA Astrophysics Data System (ADS)

    1982-02-01

    A matrix representation of the ion optics of the analyzing stage has been used in a computer model of a tandem mass spectrometer with simultaneous detection for CAD. The matrix algorithm of this model is discussed here as an elegant way of describing the ion optics in a first-order approximation. The accuracy of the calculations is illustrated by comparing calculated and measured adjustments of the instrument under normal experiment conditions. The ion-optical possibilities with respect to transmission, mass resolution influence of several ion optical parameters on the shape and position of the mass focal plane is discussed. The experimental values of mass range, mass resolution and ion transmission agree very well with the calculations. Moreover, the computer model appears to be a useful tool for giving clear insight into the operation of the rather complex ion optics of the instrument. The calculations have been further developed towards higher accuracy, making possible automatic focusing of the mass focal plane onto the detector.

  13. High performance liquid chromatography tandem mass spectrometry determination of perfluorinated acids in cow milk.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; Cavazzini, Alberto; Foglia, Patrizia; Laganà, Aldo; Piovesana, Susy; Samperi, Roberto

    2013-12-01

    A new and sensitive liquid chromatography/electrospray-tandem mass spectrometric (LC/ESI-MS/MS) method for the determination of 12 perfluorinated compounds (PFCs) in cow milk is described. Milk samples were extracted with acetone and cleaned-up by a graphitized carbon black solid-phase extraction cartridge, optimizing the entire procedure by using a screening experimental design. LC/ESI-MS/MS was performed in negative ion mode using multiple reaction monitoring mode. The performance of the method was evaluated under the optimized conditions in terms of matrix effects, range of linearity, accuracy, and repeatability. For all compounds, linearity in matrix was observed in the range LOQ-10μgL(-1), and coefficients of determination R(2) ranged from 0.9982 to 0.9999. The analytical recoveries, relative to the isotopic internal standard, measured at 10 and 50ngL(-1) were in the range of 91-105%, with relative standard deviations below 6% and method detection limit, based on the blank value +3 times the standard deviation of the blank, ranged from 0.5 to 3ngL(-1). The final method developed was used to determine the concentration of PFCs in 15 retail milk samples. None of these compounds were detected in cow milk analyzed samples.

  14. Differential Proteomic Analysis of Human Saliva using Tandem Mass Tags Quantification for Gastric Cancer Detection

    PubMed Central

    Xiao, Hua; Zhang, Yan; Kim, Yong; Kim, Sung; Kim, Jae Joon; Kim, Kyoung Mee; Yoshizawa, Janice; Fan, Liu-Yin; Cao, Cheng-Xi; Wong, David T. W.

    2016-01-01

    Novel biomarkers and non-invasive diagnostic methods are urgently needed for the screening of gastric cancer to reduce its high mortality. We employed quantitative proteomics approach to develop discriminatory biomarker signatures from human saliva for the detection of gastric cancer. Salivary proteins were analyzed and compared between gastric cancer patients and matched control subjects by using tandem mass tags (TMT) technology. More than 500 proteins were identified with quantification, and 48 of them showed significant difference expression (p < 0.05) between normal controls and gastric cancer patients, including 7 up-regulated proteins and 41 down-regulated proteins. Five proteins were selected for initial verification by ELISA and three were successfully verified, namely cystatin B (CSTB), triosephosphate isomerase (TPI1), and deleted in malignant brain tumors 1 protein (DMBT1). All three proteins could differentiate gastric cancer patients from normal control subjects, dramatically (p < 0.05). The combination of these three biomarkers could reach 85% sensitivity and 80% specificity for the detection of gastric cancer with accuracy of 0.93. This study provides the proof of concept of salivary biomarkers for the non-invasive detection of gastric cancer. It is highly encouraging to turn these biomarkers into an applicable clinical test after large scale validation. PMID:26911362

  15. Validation of salivary cortisol and testosterone assays in chimpanzees by liquid chromatography-tandem mass spectrometry.

    PubMed

    Kutsukake, Nobuyuki; Ikeda, Koki; Honma, Seijiro; Teramoto, Migaku; Mori, Yusuke; Hayasaka, Ikuo; Yamamoto, Rain; Ishida, Takafumi; Yoshikawa, Yasuhiro; Hasegawa, Toshikazu

    2009-08-01

    Owing to its high temporal sensitivity, saliva has distinct advantages for measuring steroids, compared with other noninvasive samples such as urine and feces. Here, we report the validity of assaying salivary cortisol (C) and testosterone (T) using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in captive male chimpanzees, Pan troglodytes. For both the C and T concentrations, we found positive relationships between saliva and plasma. The concentrations of C and T in saliva showed clear patterns of diurnal fluctuation, whereas those in urine and feces did not. These results suggest that the salivary steroid concentrations can be regarded as good indicators of circulating steroid levels. We also developed and validated an efficient method for collecting saliva samples from cotton rope. Although rope includes inherent steroid-like compounds and may affect the accuracy of steroid measurements, our rope-washing procedures effectively removed intrinsic steroidal materials. There was a significant association between the C and T concentrations measured from saliva collected from rope licked by the chimpanzees and those measured from saliva collected directly from the mouth. Salivary T values estimated by LC/MS-MS were similar to those measured by radioimmunoassay. The results indicate the usefulness of saliva as a noninvasive steroid measure and that steroids in the saliva of chimpanzees can be accurately measured by LC-MS/MS.

  16. Quantification of testosterone undecanoate in human hair by liquid chromatography-tandem mass spectrometry.

    PubMed

    Pozo, Oscar J; Deventer, Koen; Van Eenoo, Peter; Rubens, Robert; Delbeke, Frans T

    2009-08-01

    Testosterone undecanoate (T-C11) can be used by athletes in order to improve performance. After oral intake, T-C11 is rapidly metabolized, hampering discrimination between exogenous and endogenous testosterone. A possible alternative is to detect the intact ester in hair. A method based on liquid chromatography-tandem mass spectrometry was developed for the determination of T-C11 in hair. The sample procedure consisted of digestion of 200 mg of pulverized hair with tris(2-carboxyethyl)phosphine hydrochloride and liquid-liquid extraction with n-pentane. Several parameters such as the mobile phase, the ionization source and the washing step were optimized. The method was validated at different spiked levels obtaining satisfactory values for accuracy (between 92 and 102%) with relative standard deviations lower than 7% and a limit of detection of 0.2 ng/g. The applicability of the method was checked by the analysis of three samples from patients using T-C11. A peak for the analyte was detected in all samples with concentrations between 0.4 and 8.4 ng/g. PMID:19353724

  17. Study of tanshinone IIA tissue distribution in rat by liquid chromatography-tandem mass spectrometry method.

    PubMed

    Bi, Hui-chang; Law, Francis C P; Zhong, Guo-ping; Xu, Chen-shu; Pan, Ying; Ding, Liang; Chen, Xiao; Zhao, Li-zi; Xu, Qiong; Huang, Min

    2007-05-01

    A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for determining tanshinone IIA in rat tissues. After a single step liquid-liquid extraction with diethyl ether, tanshinone IIA and loratadine (internal standard) was subjected to LC/MS/MS analysis using positive electro-spray ionization under selected reaction monitoring mode. Chromatographic separation of tanshinone IIA and loratadine was achieved on a Hypersil BDS C(18) column (i.d. 2.1 x 50 mm, 5 microm) with a mobile phase consisting of methanol-1% formic acid (90:10, v/v) at a flow rate of 300 microL/min. The intra-day and inter-day precision of the method were less than 10.2 and 12.4%, respectively. The intra-day and inter-day accuracies ranged from 99.7 to 109.7%. The lowest limit of quantification for tanshinone IIA was 1 ng/mL. The method was applied to a tanshinone IIA tissue distribution study after an oral dose of 60 mg/kg to rats. Tanshinone IIA tissue concentrations decreased in the order of stomach > small intestine > lung > liver > fat > muscle > kidneys > spleen > heart > plasma > brain > testes. Tanshinone IIA still could be detected in most of the tissues at 20 h post-dosing. These results indicate that the LC/MS/MS method was rapid and sensitive to quantify tanshinone IIA in different rat tissues. PMID:17357178

  18. Faster and more accurate graphical model identification of tandem mass spectra using trellises

    PubMed Central

    Wang, Shengjie; Halloran, John T.; Bilmes, Jeff A.; Noble, William S.

    2016-01-01

    Tandem mass spectrometry (MS/MS) is the dominant high throughput technology for identifying and quantifying proteins in complex biological samples. Analysis of the tens of thousands of fragmentation spectra produced by an MS/MS experiment begins by assigning to each observed spectrum the peptide that is hypothesized to be responsible for generating the spectrum. This assignment is typically done by searching each spectrum against a database of peptides. To our knowledge, all existing MS/MS search engines compute scores individually between a given observed spectrum and each possible candidate peptide from the database. In this work, we use a trellis, a data structure capable of jointly representing a large set of candidate peptides, to avoid redundantly recomputing common sub-computations among different candidates. We show how trellises may be used to significantly speed up existing scoring algorithms, and we theoretically quantify the expected speedup afforded by trellises. Furthermore, we demonstrate that compact trellis representations of whole sets of peptides enables efficient discriminative learning of a dynamic Bayesian network for spectrum identification, leading to greatly improved spectrum identification accuracy. Contact: bilmes@uw.edu or william-noble@uw.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27307634

  19. Ethyl glucuronide determination in meconium and hair by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Tarcomnicu, Isabela; van Nuijs, Alexander L N; Aerts, Katrien; De Doncker, Mireille; Covaci, Adrian; Neels, Hugo

    2010-03-20

    Ethyl glucuronide (EtG) detection in non-conventional matrices, such as hair and meconium, can provide useful information on alcohol abuse over a long time frame, for example during pregnancy or after a withdrawal treatment. This study reports on the development, validation and application of a new hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the analysis of EtG in meconium and hair. For each matrix, the sample preparation and the chromatographic separation were thoroughly optimised. Additionally, experiments with reversed-phase liquid chromatography were also performed in the development stages. Analyses were carried out using a Phenomenex Luna HILIC column (150 mm x 3 mm, 5 microm) and a mobile phase composed by ammonium acetate 2mM and acetonitrile, in gradient. Different SPE cartridges (Oasis MAX, Oasis WAX, aminopropyl silica) and solvents were tested in order to obtain the highest recoveries and cleanest extracts. Optimal results were obtained for meconium with aminopropyl cartridges, while for hair an incubation of 16 h with 2 mL of water and acetonitrile (50/50, v/v) provided good results. The analytical method was validated for both matrices (meconium and hair) by assessing linearity, precision, accuracy, recovery and limit of quantification. The calibration curve concentrations ranged from 50 to 1200 pg/mg for meconium and from 20 to 1000 pg/mg for hair. Real meconium and hair samples were analyzed and results were consistent with literature. PMID:20061101

  20. Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry.

    PubMed

    Aguas, Patricia C; Fitzhenry, Matthew J; Giannikopoulos, Georgina; Varelis, Peter

    2006-08-01

    An accurate and precise method for the quantification of acrylamide using stable isotope dilution liquid chromatography-tandem mass spectrometry was developed and used to measure acrylamide in coffee and cocoa samples. The sample preparation involved extraction of the analyte and its internal standard, 13C3-acrylamide, into water and subsequent defatting of the aqueous extract with dichloromethane. An aliquot of the resulting aqueous extract was then azeotropically dried under reduced pressure and subsequently purified using an aminopropyl-bonded silica cartridge. The purified extracts were then chromatographed on a 5-microm 2.1 x 150 mm Hypercarb column, the effluent of which was monitored for the analyte and its internal standard using positive-ion APCI-selected reaction monitoring. The intra-laboratory reproducibility of the method, expressed as a relative coefficient of variation (%, n=5), was determined at four levels of concentration (12.3, 42.3, 139.3 and 464.8 microg kg(-1)) and was found to vary between 0.6-2.5%. The accuracy of the method was assessed using a reference sample of coffee. The average result obtained using our method differed from the assigned value of the reference material by less than 1%. An analysis of a cocoa sample revealed that the method is capable of precisely estimating acrylamide in challenging matrices down to a level of at least 12.3 microg kg(-1). PMID:16819634

  1. Quantification of influenza virus hemagglutinins in complex mixtures using isotope dilution tandem mass spectrometry.

    PubMed

    Williams, Tracie L; Luna, Leah; Guo, Zhu; Cox, Nancy J; Pirkle, James L; Donis, Ruben O; Barr, John R

    2008-05-12

    Influenza vaccination is the primary method for preventing influenza and its severe complications. Licensed inactivated vaccines for seasonal or pandemic influenza are formulated to contain a preset amount of hemagglutinin (HA), the critical antigen to elicit protection. Current methods to establish the HA concentration of vaccines rely on indirect measurements that are subject to considerable experimental variability. We present a liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the absolute quantification of viral proteins in a complex mixture. Through use of an isotope dilution approach, HA from viral subtypes H1, H3, H5, and B was determined both directly and rapidly. This method can be applied to purified virus preparations, to monovalent bulk concentrates, or to trivalent inactivated influenza vaccines with improved speed, sensitivity, precision, and accuracy. This LC/MS/MS approach may substantially increase the reliability of methods used to quantitate the amount of antigen in seasonal and pandemic influenza vaccines and reduce the time and effort to deliver influenza vaccines for public health use during the next influenza pandemic.

  2. Analysis of nerve agent metabolites from nail clippings by liquid chromatography tandem mass spectrometry.

    PubMed

    Appel, Amanda S; Logue, Brian A

    2016-09-15

    While several methods for the bioanalysis of nerve agents or their metabolites have been developed for the verification of nerve agent exposure, these methods are generally limited in the amount of time after an exposure that markers of exposure can be detected (due to rapid metabolism from biological matrices). In this study, a method for the analysis of nerve agent hydrolysis products from nail clippings was developed to allow evaluation of nails as a long-term repository of these markers. Pinacolyl methylphosphonic acid (PMPA) and isopropyl methylphosphonic acid (IMPA) were extracted from nail samples with N,N-dimethylformamide and subsequently analyzed by liquid chromatography-tandem mass spectrometry. Limits of detection for PMPA and IMPA were 0.3μg/kg and 7.5μg/kg and linear ranges were 0.75-300μg/kg and 30-1500μg/kg, respectively. Precision was within 10% and 8% for PMPA and IMPA, respectively, and accuracy was 100±12% for both analytes. The approach presented here is complementary to current methods for nerve agent exposure verification, and should allow for long-term determination of nerve agent poisoning. PMID:27474780

  3. Isotopologue Distributions of Peptide Product Ions by Tandem Mass Spectrometry: Quantitation of Low Levels of Deuterium Incorporation1

    PubMed Central

    Wang, Benlian; Sun, Gang; Anderson, David R.; Jia, Minghong; Previs, Stephen; Anderson, Vernon E.

    2007-01-01

    Protonated molecular peptide ions and their product ions generated by tandem mass spectrometry appear as isotopologue clusters due to the natural isotopic variations of carbon, hydrogen, nitrogen, oxygen and sulfur. Quantitation of the isotopic composition of peptides can be employed in experiments involving isotope effects, isotope exchange, isotopic labeling by chemical reactions, and studies of metabolism by stable isotope incorporation. Both ion trap and quadrupole-time of flight mass spectrometry are shown to be capable of determining the isotopic composition of peptide product ions obtained by tandem mass spectrometry with both precision and accuracy. Tandem mass spectra obtained in profile-mode of clusters of isotopologue ions are fit by non-linear least squares to a series of Gaussian peaks (described in the accompanying manuscript) which quantify the Mn/M0 values which define the isotopologue distribution (ID). To determine the isotopic composition of product ions from their ID, a new algorithm that predicts the Mn/M0 ratios is developed which obviates the need to determine the intensity of all of the ions of an ID. Consequently a precise and accurate determination of the isotopic composition a product ion may be obtained from only the initial values of the ID, however the entire isotopologue cluster must be isolated prior to fragmentation. Following optimization of the molecular ion isolation width, fragmentation energy and detector sensitivity, the presence of isotopic excess (2H, 13C, 15N, 18O) is readily determined within 1%. The ability to determine the isotopic composition of sequential product ions permits the isotopic composition of individual amino acid residues in the precursor ion to be determined. PMID:17559791

  4. Deciphering Modifications in Swine Cardiac Troponin I by Top-Down High-Resolution Tandem Mass Spectrometry

    PubMed Central

    Zhang, Jiang; Dong, Xintong; Hacker, Timothy A.; Ge, Ying

    2011-01-01

    Cardiac troponin I (cTnI) is an important regulatory protein in cardiac muscle and its modification represents a key mechanism in the regulation of cardiac muscle contraction and relaxation. cTnI is often referred to as the “gold-standard” serum biomarker for diagnosing patients with acute cardiac injury since it is unique to the heart and released into the circulation following necrotic death of cardiac tissue. The swine (Sus scrofa) heart model is extremely valuable for cardiovascular research since the heart anatomy and coronary artery distribution of swine are almost identical to those of humans. Herein we report a comprehensive characterization of the modifications in swine cTnI using top-down high-resolution tandem mass spectrometry in conjugation with immunoaffinity chromatography purification. High-resolution high accuracy mass spectrometry revealed that swine cTnI affinity purified from domestic pig hearts was N-terminally acetylated and phosphorylated. Electron capture disassociation is uniquely suited for localization of labile phosphorylations, which unambiguously identified Ser22/Ser23 as the only basally phosphorylation sites that are well-known to be regulated by protein kinase A and protein kinase C. Moreover, a combination of tandem mass spectrometry with sequence homology alignment effectively localized a single amino acid polymorphism, V116A, representing a novel genetic variant of swine cTnI. Overall, our studies demonstrated the unique power of top-down high-resolution tandem mass spectrometry in the characterization of protein modifications including labile phosphorylation and unexpected sequence variants. PMID:20223681

  5. Silver Coating for High-Mass-Accuracy Imaging Mass Spectrometry of Fingerprints on Nanostructured Silicon.

    PubMed

    Guinan, Taryn M; Gustafsson, Ove J R; McPhee, Gordon; Kobus, Hilton; Voelcker, Nicolas H

    2015-11-17

    Nanostructure imaging mass spectrometry (NIMS) using porous silicon (pSi) is a key technique for molecular imaging of exogenous and endogenous low molecular weight compounds from fingerprints. However, high-mass-accuracy NIMS can be difficult to achieve as time-of-flight (ToF) mass analyzers, which dominate the field, cannot sufficiently compensate for shifts in measured m/z values. Here, we show internal recalibration using a thin layer of silver (Ag) sputter-coated onto functionalized pSi substrates. NIMS peaks for several previously reported fingerprint components were selected and mass accuracy was compared to theoretical values. Mass accuracy was improved by more than an order of magnitude in several cases. This straightforward method should form part of the standard guidelines for NIMS studies for spatial characterization of small molecules.

  6. Cytokinin profiling in plant tissues using ultra-performance liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Novák, Ondrej; Hauserová, Eva; Amakorová, Petra; Dolezal, Karel; Strnad, Miroslav

    2008-08-01

    We have developed a simple, high-throughput batch immunoextraction (IAE) micropurification procedure for extracting a wide range of naturally occurring cytokinins (bases, ribosides, O- and N-glucosides, and nucleotides) from plant tissues in solutions that are compatible with ultra-performance liquid chromatography (UPLC), thereby facilitating sensitive subsequent analysis. The UPLC system was coupled to a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray interface (ESI). Small (mg) amounts of tissues were purified by solid-phase extraction (SPE) followed by an immunoaffinity clean-up step and two fast chromatographic separations of most cytokinin metabolites (bases, ribosides, and 9-glucosides in the first, O-glucosides and nucleotides in the second). Using UPLC, the runs were up to 4-fold faster than in standard cytokinin analyses, and both retention times and injection volumes were less variable (RSDs, 0.15-0.3% and 1.0-5.5%, respectively). In multiple reaction monitoring (MRM) mode, the detection limit for most of the cytokinins analyzed was close to 1 fmol (5-25 fmol for O-glucosides and nucleotides) and the linear range spanned at least five orders of magnitude. The extraction and purification method was optimized using poplar (Populusxcanadensis Moench, cv Robusta) leaf samples, and the analytical accuracy was further validated using IAE-purified 10-day-old Arabidopsis thaliana plants spiked with 1 and 10 pmol of cytokinin derivatives. This approach can be used for rapid, sensitive qualitative and/or quantitative analysis of more than 50 natural cytokinins in minute amounts of plant tissues with high performance, robustness, and accuracy.

  7. High performance liquid chromatography tandem mass spectrometry assay for the determination of cobinamide in pig plasma.

    PubMed

    McCracken, Brent A; Brittain, Matthew K

    2015-12-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been widely utilized for the analysis of compounds in biological matrices due to its selectivity and sensitivity. This study describes the application of an LC-MS/MS-based approach toward the analysis of cobinamide in Yorkshire pig plasma. The selectivity, accuracy, precision, recovery, linearity, range, carryover, sensitivity, matrix effect, interference, stability, reproducibility, and ruggedness of the method were investigated in pig plasma. The accuracy and precision of the method was determined to be within 10% over three different days over a range of concentrations (25-10,000ng/mL) that spanned more than two orders of magnitude. The lower limit of quantitation (LLOQ) for dicyanocobinamide was determined to be 25ng/mL in pig plasma. Carryover was acceptable, as the area response of the carryover blanks were ≤15% of the area response of the nearest LLOQ standard for the analyte, while it was nonexistent for the internal standard. Specificity was ensured using six different lots of pig plasma. While the matrix effects of dicyanocobinamide in plasma were enhanced, ginsenoside Rb1 experienced signal suppression under the described conditions. The absolute recovery results for both compounds were consistent, precise, and reproducibly lower than expected at ∼60% for dicyanocobinamide and ∼22% for ginsenoside Rb1, confirming that a matrix standard curve was required for accurate quantitation. Cobinamide was shown to be very stable in matrix at various storage conditions including room temperature, refrigerated, and frozen at time intervals of 20h, 4 days, and 60 days respectively. This method was demonstrated to be sensitive, reproducible, stable, and rugged, and it should be applicable to the analysis of cobinamide in other biological matrices and species.

  8. Determination of Heterocyclic Amines and Acrylamide in Agricultural Products with Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Lee, Kyung-Jun; Lee, Gae-Ho; Kim, HaeSol; Oh, Min-Seok; Chu, Seok; Hwang, In Ju; Lee, Jee-yeon; Choi, Ari; Kim, Cho-il

    2015-01-01

    Heterocyclic amines (HCAs) and acrylamide are unintended hazardous substances generated by heating or processing of foods and are known as carcinogenic and mutagenic agents by the animal experiments. A simple method was established for a rapid and accurate determination of 12 types of HCAs (IQ, MeIQ, Glu-P-1, Glu-P-2, MeIQx, Trp-P-1, Trp-P-2, PhIP, AαC, MeAαC, Harman and Norharman) and acrylamide in three food matrices (non-fat liquid, non-fat solid and fat solid) by isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). In every sample, a mixture of internal standards including IQ-d3, MeIQx-d3, PhIP-d3, Trp-P-2-13C2-15N and MeAαC-d3 was spiked for quantification of HCAs and 13C3-acrylamide was also spiked for the analysis of acrylamide. HCAs and acrylamide in sample were extracted with acetonitrile and water, respectively, and then two solid-phase extraction cartridges, ChemElut: HLB for HCAs and Accucat: HLB for acrylamide, were used for efficiently removing interferences such as pigment, lipid, polar, nonpolar and ionic compounds. Established method was validated in terms of recovery, accuracy, precision, limit of detection, limit of quantitation, and linearity. This method showed good precision (RSD < 20%), accuracy (71.8~119.1%) and recovery (66.0~118.9%). The detection limits were < 3.1 ng/g for all analytes. The correlation coefficients for all the HCAs and acrylamide were > 0.995, showing excellent linearity. These methods for the detection of HCAs and acrylamide by LC-MS/MS were applied to real samples and were successfully used for quantitative monitoring in the total diet study and this can be applied to risk assessment in various food matrices. PMID:26483884

  9. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    PubMed

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes. PMID:26315495

  10. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    PubMed

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes.

  11. Simulation of two dimensional electrophoresis and tandem mass spectrometry for teaching proteomics.

    PubMed

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations-2D electrophoresis and tandem mass spectrometry. The two simulations are integrated together and are designed to teach the concept of proteome analysis of prokaryotic and eukaryotic organisms. 2DE-Tandem MS can be used as a freestanding simulation, or in conjunction with a wet lab, to introduce proteomics in the undergraduate classroom. 2DE Tandem MS is a free program available on Sourceforge at https://sourceforge.net/projects/jbf/. It was developed using Java Swing and functions in Mac OSX, Windows, and Linux, ensuring that every student sees a consistent and informative graphical user interface no matter the computer platform they choose. Java must be installed on the host computer to run 2DE Tandem MS. Example classroom exercises are provided in the Supporting Information.

  12. Tandem mass spectrometry newborn screening for inborn errors of intermediary metabolism: abnormal profile interpretation.

    PubMed

    Fernández-Lainez, C; Aguilar-Lemus, J J; Vela-Amieva, M; Ibarra-González, I

    2012-01-01

    Expanded newborn screening for inherited metabolic disorders using tandem mass spectrometry was introduced in 1990's and is widely used around the world. In contrast to conventional screening methods, tandem mass spectrometry does not measure single analytes but identifies and quantifies metabolite profiles; one single blood spot analyzed provides information of about 60 metabolites including amino acids, acylcarnitines and related ratios that enable the diagnosis of approximately 50 different diseases. However, the interpretation of these profiles can become quite complex. The aim of this work is to present in an easy and practical manner a comprehensive compilation of information needed for tandem mass neonatal screening profile interpretation, and basic actions for immediate follow up of abnormal results, including the tests that are required for confirmatory purposes. Other conditions not attributable to metabolic disorders which can lead to an abnormal profile of these markers are also described as well as a series of general recommendations which would be useful for health professionals who are beginning newborn screening for inborn errors of intermediary metabolism using tandem mass spectrometry.

  13. Combined Dynamic Arrays for Storing and Searching Semi-Ordered Tandem Mass Spectrometry Data

    Technology Transfer Automated Retrieval System (TEKTRAN)

    When performing bioinformatics analysis on tandem mass spectrometry data, there is a computational need to efficiently store and sort these semi-ordered data sets. To solve this problem, a new data structure based on dynamic arrays was designed and implemented in an algorithm that parses semi-order...

  14. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  15. Making the Case for Objective Performance Metrics in Newborn Screening by Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Rinaldo, Piero; Zafari, Saba; Tortorelli, Silvia; Matern, Dietrich

    2006-01-01

    The expansion of newborn screening programs to include multiplex testing by tandem mass spectrometry requires understanding and close monitoring of performance metrics. This is not done consistently because of lack of defined targets, and interlaboratory comparison is almost nonexistent. Between July 2004 and April 2006 (N = 176,185 cases), the…

  16. MEASUREMENT OF OXIDATIVE STRESS PARAMETERS USING LIQUID CHROMATOGRAPHY - TANDEM MASS SPECTROSCOPY (LC-MS/MS)

    EPA Science Inventory

    What is the study?
    An invited review article. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
    Why was it done?
    Although oxidative stress is frequently cited as a cause of various adverse biological eff...

  17. Greazy: Open-Source Software for Automated Phospholipid Tandem Mass Spectrometry Identification.

    PubMed

    Kochen, Michael A; Chambers, Matthew C; Holman, Jay D; Nesvizhskii, Alexey I; Weintraub, Susan T; Belisle, John T; Islam, M Nurul; Griss, Johannes; Tabb, David L

    2016-06-01

    Lipid identification from data produced with high-throughput technologies is essential to the elucidation of the roles played by lipids in cellular function and disease. Software tools for identifying lipids from tandem mass (MS/MS) spectra have been developed, but they are often costly or lack the sophistication of their proteomics counterparts. We have developed Greazy, an open source tool for the automated identification of phospholipids from MS/MS spectra, that utilizes methods similar to those developed for proteomics. From user-supplied parameters, Greazy builds a phospholipid search space and associated theoretical MS/MS spectra. Experimental spectra are scored against search space lipids with similar precursor masses using a peak score based on the hypergeometric distribution and an intensity score utilizing the percentage of total ion intensity residing in matching peaks. The LipidLama component filters the results via mixture modeling and density estimation. We assess Greazy's performance against the NIST 2014 metabolomics library, observing high accuracy in a search of multiple lipid classes. We compare Greazy/LipidLama against the commercial lipid identification software LipidSearch and show that the two platforms differ considerably in the sets of identified spectra while showing good agreement on those spectra identified by both. Lastly, we demonstrate the utility of Greazy/LipidLama with different instruments. We searched data from replicates of alveolar type 2 epithelial cells obtained with an Orbitrap and from human serum replicates generated on a quadrupole-time-of-flight (Q-TOF). These findings substantiate the application of proteomics derived methods to the identification of lipids. The software is available from the ProteoWizard repository: http://tiny.cc/bumbershoot-vc12-bin64 . PMID:27186799

  18. Accurate characterization of carcinogenic DNA adducts using MALDI tandem time-of-flight mass spectrometry

    NASA Astrophysics Data System (ADS)

    Barnes, Charles A.; Chiu, Norman H. L.

    2009-01-01

    Many chemical carcinogens and their in vivo activated metabolites react readily with genomic DNA, and form covalently bound carcinogen-DNA adducts. Clinically, carcinogen-DNA adducts have been linked to various cancer diseases. Among the current methods for DNA adduct analysis, mass spectroscopic method allows the direct measurement of unlabeled DNA adducts. The goal of this study is to explore the use of matrix-assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF MS) to determine the identity of carcinogen-DNA adducts. Two of the known carcinogenic DNA adducts, namely N-(2'-deoxyguanosin-8-yl)-2-amino-1-methyl-6-phenyl-imidazo [4,5-b] pyridine (dG-C8-PhIP) and N-(2'-deoxyguanosin-8yl)-4-aminobiphenyl (dG-C8-ABP), were selected as our models. In MALDI-TOF MS measurements, the small matrix ion and its cluster ions did not interfere with the measurements of both selected dG adducts. To achieve a higher accuracy for the characterization of selected dG adducts, 1 keV collision energy in MALDI-TOF/TOF MS/MS was used to measure the adducts. In comparison to other MS/MS techniques with lower collision energies, more extensive precursor ion dissociations were observed. The detection of the corresponding fragment ions allowed the identities of guanine, PhIP or ABP, and the position of adduction to be confirmed. Some of the fragment ions of dG-C8-PhIP have not been reported by other MS/MS techniques.

  19. [Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry].

    PubMed

    Wang, Xiupin; Li, Peiwu; Yang, Yang; Zhang, Wen; Zhang, Qi; Fan, Sufang; Yu, Li; Wang, Lin; Chen, Xiaomei; Li, Ying; Jiang, Jun

    2011-06-01

    The high performance liquid chromatography (HPLC)-triple quadrupole tandem mass spectrometry was applied for the determination of the aflatoxins: B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2), in cereals and oils. The samples were first extracted by ultrasonic method. The optimized conditions of ultrasonic extraction were as follows: temperature of 50 degrees C, extraction time of 3 min, methanol-water (containing 40 g/L NaCl) (80: 20, v/v) solution as the medium and a ratio of sample to solvent of 1 : 3 (g: mL). The extracts were then purified using an immunoaffinity column. The separation was performed on a C18 column with mobile phases of 10 mmol/L ammonium acetate and methanol in gradient elution. The sensitive detection of the four AFT compounds by electrospray ionization mass spectrometry (ESI-MS) was carried out in selected reaction monitoring (SRM) mode with aflatoxin M1 (AFM1) as the internal standard. Under the optimized conditions, the limits of detection of AFB1, AFB2, AFG1 and AFG2 were 0.002, 0.004, 0.004 and 0.012 microg/kg, respectively. The recoveries of aflatoxins in different spiked cereals and oils were in the range from 87% to 111%. The intra-day and inter-day precisions were not more than 6.7% and 5.6%, respectively. In comparison with the external standard method, this method can effectively inhibit the matrix effects, and greatly improve the accuracy.

  20. Detection of efaproxiral (RSR13) and its metabolites in equine by liquid chromatography tandem mass spectrometry.

    PubMed

    Yi, Rong; Sandhu, Jasmeet; Zhao, Sarah; Lam, Geoffrey; Loganathan, Devan; Morrissey, Barbara

    2014-01-01

    Efaproxiral (RSR 13) is an experimental synthetic allosteric modifier of haemoglobin (Hb) that acts by increasing the release of oxygen from Hb to the surrounding tissues. It has been shown to increase maximum oxygen uptake (VO(2max)) in a canine skeletal muscle model. The ability to increase maximal muscle oxygen uptake makes efaproxiral a potential performance-enhancing agent and is therefore prohibited by the World Anti-Doping Agency. In this study, a method for the detection and elimination of efaproxiral in equine plasma and urine after a 2.5 g intravenous administration of efaproxiral is described. Post administration plasma and urine samples were collected up to 120 h. Efaproxiral was detected up to 120 h in urine and up to 78 h in plasma. In plasma, the peak concentration was 42 µg/ml and detected at 5 min post administration. In urine, the peak concentration was 2.8 mg/ml and detected at 0-1 h post administration. A validated liquid chromatography tandem mass spectrometry method was used for the quantitation of efaproxiral in equine plasma and urine. The limit of detection of the method is 0.05 ng/ml in plasma and 0.1 ng/ml in urine. The method is highly sensitive and specific with good precision, accuracy and recovery. The manuscript also describes the systematic identification of efaproxiral metabolites detected in post administration equine urine samples. The metabolites were identified by use of enhanced mass spectra and enhanced product ion scans. Both positive and negative mode ionizations were utilized for metabolite identification and plausible fragmentation pathways were proposed for the phase 1 metabolite identified. In addition to free efaproxiral, one phase 1 metabolite and two phase 2 metabolites were identified in post administration urine. PMID:24446264

  1. Quantitative determination of nebivolol from human plasma using liquid chromatography-tandem mass spectrometry.

    PubMed

    Nandania, Jatin; Rajput, S J; Contractor, Pritesh; Vasava, Pragnesh; Solanki, Bhavik; Vohra, Mohsin

    2013-04-01

    In the present work, a rapid, sensitive, specific, precise and accurate liquid chromatography-tandem mass spectrometry method for determination of nebivolol in human plasma was developed and validated with a large calibration curve range (50-5000 pg/mL) which can be used for routine drug analysis and bioequivalence studies. Liquid-liquid extraction method was used to extract the analyte from the human plasma. The separation was achieved using Waters symmetry, C18, 4.6 × 150 mm, 5 μm column with formic acid in water, 0.01%, v/v: Acetonitrile (40:60) as a mobile phase. A flow rate of 0.8 mL/min, no splitting and run time 2.00 min was used for the chromatographic analysis of nebivolol. Sensitivity of this method was found to be 30 pg/mL. The analyte was analyzed by mass spectrometry in the multiple reaction monitoring mode. A Turbo-Ion spray source was interfaced between the HPLC and triple quadrupole mass spectrometer (MDS Sciex API 4000). The precursor-product ion m/z 406.00-151.00 for nebivolol and m/z 410.20-151.00 for nebivolol-D4 were used for quantification of an analyte and its IS. The method was validated in terms of accuracy, precision, selectivity, absolute recovery, freeze-thaw stability, bench-top stability, dry extract stability, short and long term stock solution stability, wet extract stability and re-injection reproducibility. The within- and between-batch accuracy was found to lie within the range of 87.00-100.40% and within- and between-batch precision was obtained within the range 0.33-8.67%. The mean recovery of all three concentration levels for drug was obtained 67.67% where as the mean recovery of IS was 68.74%. The %RSD value at higher concentration and lower concentration in all stability experiments was within 15%. This method is free from ion suppression, ion enhancement and any type of abnormal ionization.

  2. Atmospheric sampling glow discharge ionizataion and triple quadrupole tandem mass spectrometry for explosives vapor detection

    SciTech Connect

    McLuckey, S.A.; Goeringer, D.E.; Asano, K.G.; Hart, K.J.; Glish, G.L.; Grant, B.C.; Chambers, D.M.

    1993-08-01

    The detection and identification of trace vapors of hidden high explosives is an excellent example of a targeted analysis problem. It is desirable to push to ever lower levels the quantity or concentration of explosives material that provides an analytical signal, while at the same time discriminating against all other uninteresting material. The detection system must therefore combine high sensitivity with high specificity. This report describes the philosophy behind the use of atmospheric sampling glow discharge ionization, which is a sensitive, rugged, and convenient means for forming anions from explosives molecules, with tandem mass spectrometry, which provides unparalleled specificity in the identification of explosives-related ions. Forms of tandem mass spectrometry are compared and contrasted to provide a summary of the characteristics to be expected from an explosives detector employing mass spectrometry/mass spectrometry. The instrument developed for the FAA, an atmospheric sampling glow discharge/triple quadrupole mass spectrometer, is described in detail with particular emphasis on the ion source/spectrometer interface and on the capabilities of the spectrometer. Performance characteristics of the system are also described as they pertain to explosives of interest including a description of an automated procedure for the detection and identification of specific explosives. A comparison of various tandem mass spectrometers mated with atmospheric sampling glow discharge is then described and preliminary studies with a vapor preconcentration system provided by the FAA will be described.

  3. High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers

    NASA Astrophysics Data System (ADS)

    Cotter, Robert J.

    2013-05-01

    Long before the introduction of matrix-assisted laser desorption/ionization (MALDI), electrospray ionization (ESI), Orbitraps, and any of the other tools that are now used ubiquitously for proteomics and metabolomics, the highest performance mass spectrometers were sector instruments, providing high resolution mass measurements by combining an electrostatic energy analyzer (E) with a high field magnet (B). In its heyday, the four sector mass spectrometer (or EBEB) was the crown jewel, providing the highest performance tandem mass spectrometry using single, high energy collisions to induce fragmentation. During a time in which quadrupole and tandem triple quadrupole instruments were also enjoying increased usage and popularity, there were, nonetheless, some clear advantages for sectors over their low collision energy counterparts. Time-of-flight (TOF) mass spectrometers are high voltage, high vacuum instruments that have much in common with sectors and have inspired the development of tandem instruments exploiting single high energy collisions. In this retrospective, we recount our own journey to produce high performance TOFs and tandem TOFs, describing the basic theory, problems, and the advantages for such instruments. An experiment testing impulse collision theory (ICT) underscores the similarities with sector mass spectrometers where this concept was first developed. Applications provide examples of more extensive fragmentation, side chain cleavages, and charge-remote fragmentation, also characteristic of high energy sector mass spectrometers. Moreover, the so-called curved-field reflectron has enabled the design of instruments that are simpler, collect and focus all of the ions, and may provide the future technology for the clinic, for tissue imaging, and the characterization of microorganisms.

  4. Data requirements for protein identification using chemically-assisted fragmentation and tandem mass spectrometry.

    PubMed

    Juhlin, Kenton D; Swift, Dionne D; Lacey, Martin P; Correa, Paul E; Keough, Thomas W

    2005-01-01

    Many laboratories identify proteins by searching tandem mass spectrometry data against genomic or protein sequence databases. These database searches typically use the measured peptide masses or the derived peptide sequence and, in this paper, we focus on the latter. We study the minimum peptide sequence data requirements for definitive protein identification from protein sequence databases. Accurate mass measurements are not needed for definitive protein identification, even when a limited amount of sequence data is available for searching. This information has implications for the mass spectrometry performance (and cost), data base search strategies and proteomics research.

  5. Simultaneous determination of tanshinone IIA and its three hydroxylated metabolites by liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Peng; Wang, Guang-Ji; Li, Jing; Hao, Hai-Ping; Zheng, Chao-Nan

    2006-01-01

    A rapid and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of tanshinone IIA and its three hydroxylated metabolites, tanshinone IIB, hydroxytanshinone IIA and przewaquinone A, in a rat liver microsome was developed and fully validated. A single step of liquid-liquid extraction with ethyl acetate was utilized in this method. Chromatographic separation of the sample matrix from the analytes and the internal standard diazepam was performed using a Shim-pack VP-ODS analytical column. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source and operated in selected reaction monitoring (SRM) mode. The method was linear in the concentration range of 1-500 ng/mL for all analytes. The intra- and inter-day precisions (RSD %) were within 15% and deviations of the assay accuracies were within 15.0% for all analytes. The analytes proved to be stable during sample storage, preparation and analyses. This validated method was successfully applied to the enzyme kinetic study of tanshinone IIA in liver microsome. The elimination of tanshinone IIA and formation of tanshinone IIB and hydroxytanshinone IIA in the liver microsome all exhibited a sigmoidal kinetics profile. The formation of przewaquinone A shows a typical hyperbolic profile. In addition, this method has now been applied in the analysis of other bio-samples including plasma, urine, bile and feces. PMID:16470728

  6. Determination of rizatriptan in human plasma by liquid chromatographic-eletrospray tandem mass spectrometry: application to a pharmacokinetic study.

    PubMed

    Guo, Ji-fen; Zhang, Ai-jun; Zhao, Ling; Sun, Xiao-hong; Zhao, Yi-min; Gao, Hong-zhi; Liu, Ze-yuan; Qiao, Shan-yi

    2006-01-01

    A sensitive liquid chromatographic-tandem mass spectrometry(LC-MS/MS) method was developed for the determination of rizatriptan in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax XDB C8 column (150 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an electrospray ionization interface. Zomitriptan was used as the internal standard. The method had a lower limit of quantitation of 50 pg/mL for rizatriptan, which showed more sensitivity and speed of analysis compared with reported methods. The within- and between-day precision was measured to be below 11.71% and accuracy between -5.87 and 0.86% for all quality control samples. This quantitation method was successfully applied to the evaluation of the pharmacokinetic profiles of rizatriptan after single oral administration of 5, 10 and 15 mg rizatriptan tablets to 10 healthy volunteers (five males and five females). PMID:15954161

  7. Enantioselective determination of protein amino acids in fertilizers by liquid chromatography-tandem mass spectrometry on chiral teicoplanin stationary phase.

    PubMed

    Taujenis, Lukas; Olšauskaitė, Vilma; Padarauskas, Audrius

    2014-11-19

    High-performance liquid chromatography on a glycopeptide antibiotic teicoplanin-based chiral stationary phase coupled with tandem mass spectrometry was developed for fast and reliable enantioseparation and determination of protein amino acids in hydrolyzed fertilizer samples. The effect of the mobile phase parameters (type and content of organic modifier and pH) and the column temperature on the enantioselectivity was investigated. Under optimized conditions, the majority (15 of 19) of d/l-amino acid pairs were resolved with a resolution factor (Rs) higher than 1.5 with a run time of 15 min. A triple quadrupole tandem mass spectrometer operating in multiple reaction monitoring mode with an electrospray ionization (ESI) ion source was employed for detection. The method was validated in terms of linearity, limits of detection, limits of quantitation, precision, and accuracy. Linear responses were obtained with determination coefficients higher than 0.998 for all analytes, and limits of detection were from 0.04 to 0.24 μg/mL. Sample spike/recovery experiments gave recovery values ranging from 73% for d-threonine to 116% for L-tryptophan. Relative standard deviations for inter- and intraday precision experiments were lower than 21.7%. The developed method was successfully applied for determination of the free amino acid enantiomers in five commercially available hydrolyzed protein fertilizer samples.

  8. Simultaneous analysis of ten phytohormones in Sargassum horneri by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.

    PubMed

    Li, Yan; Zhou, Chengxu; Yan, Xiaojun; Zhang, Jinrong; Xu, Jilin

    2016-05-01

    Phytohormones have attracted wide attention due to their important biological functions. However, their detection is still a challenge because of their complex composition, low abundance and diverse sources. In this study, a novel method of high-performance liquid chromatography with electrospray ionization tandem mass spectrometry was developed and validated for the simultaneous determination of ten phytohormones including indole-3-acetic acid, isopentenyladenine, isopentenyl adenosine, trans-zeatin riboside, zeatin, strigolactones, abscisic acid, salicylic acid, gibberellin A3, and jasmonic acid in Sargassum horneri (S. horneri). The phytohormones were extracted from freeze-dried S. horneri with methanol/water/methanoic acid (15:4:1, v/v/v) analyzed on a Hypersil Gold C18 column and detected by electrospray ionization tandem triple quadrupole mass spectrometry in the multiple reaction monitoring mode. The experimental conditions for the extraction and analysis of phytohormones were optimized and validated in terms of reproducibility, linearity, sensitivity, recovery, accuracy, and stability. Distributions of the phytohormones in the stems, blades, and gas bladder of the S. horneri in drift, fixed, and semi-fixed growing states were investigated for the first time. The observed contents of the phytohormones in S. horneri range from not detected to 5066.67 ng/g (fresh weight). Most phytohormones are distributed mainly in the stems of S. horneri in drift and semi-fixed states. PMID:26990813

  9. Highly sensitive and accurate screening of 40 dyes in soft drinks by liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Feng, Feng; Zhao, Yansheng; Yong, Wei; Sun, Li; Jiang, Guibin; Chu, Xiaogang

    2011-06-15

    A method combining solid phase extraction with high performance liquid chromatography-electrospray ionization tandem mass spectrometry was developed for the highly sensitive and accurate screening of 40 dyes, most of which are banned in foods. Electrospray ionization tandem mass spectrometry was used to identify and quantify a large number of dyes for the first time, and demonstrated greater accuracy and sensitivity than the conventional liquid chromatography-ultraviolet/visible methods. The limits of detection at a signal-to-noise ratio of 3 for the dyes are 0.0001-0.01 mg/L except for Tartrazine, Amaranth, New Red and Ponceau 4R, with detection limits of 0.5, 0.25, 0.125 and 0.125 mg/L, respectively. When this method was applied to screening of dyes in soft drinks, the recoveries ranged from 91.1 to 105%. This method has been successfully applied to screening of illegal dyes in commercial soft drink samples, and it is valuable to ensure the safety of food.

  10. Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Fang, Wenfang B; Andrenyak, David M; Moody, David E; Nuwayser, Elie S

    2005-04-01

    Nalmefene is an opioid antagonist used in the treatment of alcoholism and opioid overdose. A highly sensitive method was developed to measure nalmefene in human and rabbit plasma and rabbit serum. Nalbuphine was used as internal standard. Liquid-liquid extraction was applied using n-butyl chloride/acetonitrile (4:1). High-performance liquid chromatography interfaced by electrospray ionization to a tandem mass spectrometer was used for quantitation. Primary validation experiments were conducted using human plasma then it was cross-validated in rabbit plasma and rabbit serum. Specificity (peak-area ratio of blank plasma or serum to its internal standard as percent of peak-area ratio of blank plasma or serum fortified with 0.1 ng/mL nalmefene to its internal standard) ranged from 2.09 to 5.29 with a mean of 3.21% for human plasma and from 4.08 to 6.63 with a mean of 5.55% for rabbit plasma and from 2.47 to 6.17 with a mean of 3.62% for rabbit serum. The mean recovery for nalmefene was 80% in human plasma. The calibration range was from 0.1 to 100 ng/mL. Intrarun accuracy of the lower limit of quantitation (0.1 ng/mL) in all matrices was within 18.0% of target with intrarun precision within 13.6%. At 0.3, 35, and 75 ng/mL, the intrarun accuracy in all matrices was within 11.9% of target with intrarun precision within 6.6%. The inter-run accuracy in human plasma was within 8.0% of target with inter-run precision within 6.6%. Nalmefene was stable in human and rabbit plasma and rabbit serum for up to 24 h at room temperature and in human plasma after three freeze-thaw cycles. Following intravenous injection of 5 mg/kg nalmefene to rabbits, the mean area under curve for 0 to 24 h was 1116 (ng)(mL)(-1)(h), and the mean plasma clearance was 67.9 (mL)(min)(-1)(kg)(-1).

  11. Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

    PubMed

    Hu, Bin; Peng, Xuejiao; Yang, Shuiping; Gu, Haiwei; Chen, Huanwen; Huan, Yanfu; Zhang, Tingting; Qiao, Xiaolin

    2010-02-01

    Without any sample pretreatment, effervescent beverage fluids were manually sprayed into the primary ion plume created by using a nanoelectrospray ionization source for direct ionization, and the analyte ions of interest were guided into an ion trap mass spectrometer for tandem mass analysis. Functional ingredients (e.g., vitamins, taurine, and caffeine, etc.) and spiked impurity (e.g., cocaine) in various beverages, such as Red Bull energy drink, Coco-cola, and Pepsi samples were rapidly identified within 1.5 s. The limit of detection was found to be 7-15 fg (S/N = 3) for cocaine in different samples using the characteristic fragment (m/z 150) observed in the MS(3) experiments. Typical relative standard deviation and recovery of this method were 6.9%-8.6% and 104%-108% for direct analysis of three actual samples, showing that nanoextractive electrospray ionization tandem mass spectrometry is a useful technique for fast screening cocaine presence in beverages.

  12. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    PubMed

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources.

  13. Quantitation of protein post-translational modifications using isobaric tandem mass tags.

    PubMed

    Liang, Hui-Chung; Lahert, Emma; Pike, Ian; Ward, Malcolm

    2015-01-01

    Post-translational modifications (PTMs) of proteins are known to modulate many cellular processes and their qualitative and quantitative evaluation is fundamental for understanding the mechanisms of biological events. Over the past decade, improvements in sample preparation techniques and enrichment strategies, the development of quantitative labeling strategies, the launch of a new generation of mass spectrometers and the creation of bioinformatics tools for the interrogation of ever larger datasets has established MS-based quantitative proteomics as a powerful workflow for global proteomics, PTM analysis and the elucidation of key biological mechanisms. With the advantage of their multiplexing capacity and the flexibility of an ever-growing family of different peptide-reactive groups, isobaric tandem mass tags facilitate quantitative proteomics and PTM experiments and enable higher sample throughput. In this review, we focus on the technical concept and utility of the isobaric tandem mass tag labeling approach to PTM analysis, including phosphorylation, glycosylation and S-nitrosylation. PMID:25697195

  14. Approaches towards the automated interpretation and prediction of electrospray tandem mass spectra of non-peptidic combinatorial compounds.

    PubMed

    Klagkou, Katerina; Pullen, Frank; Harrison, Mark; Organ, Andy; Firth, Alistair; Langley, G John

    2003-01-01

    Combinatorial chemistry is widely used within the pharmaceutical industry as a means of rapid identification of potential drugs. With the growth of combinatorial libraries, mass spectrometry (MS) became the key analytical technique because of its speed of analysis, sensitivity, accuracy and ability to be coupled with other analytical techniques. In the majority of cases, electrospray mass spectrometry (ES-MS) has become the default ionisation technique. However, due to the absence of fragment ions in the resulting spectra, tandem mass spectrometry (MS/MS) is required to provide structural information for the identification of an unknown analyte. This work discusses the first steps of an investigation into the fragmentation pathways taking place in electrospray tandem mass spectrometry. The ultimate goal for this project is to set general fragmentation rules for non-peptidic, pharmaceutical, combinatorial compounds. As an aid, an artificial intelligence (AI) software package is used to facilitate interpretation of the spectra. This initial study has focused on determining the fragmentation rules for some classes of compound types that fit the remit as outlined above. Based on studies carried out on several combinatorial libraries of these compounds, it was established that different classes of drug molecules follow unique fragmentation pathways. In addition to these general observations, the specific ionisation processes and the fragmentation pathways involved in the electrospray mass spectra of these systems were explored. The ultimate goal will be to incorporate our findings into the computer program and allow identification of an unknown, non-peptidic compound following insertion of its ES-MS/MS spectrum into the AI package. The work herein demonstrates the potential benefit of such an approach in addressing the issue of high-throughput, automated MS/MS data interpretation.

  15. Tandem mass spectrometry of coprogen and deferoxamine hydroxamic siderophores.

    PubMed

    Simionato, Ana V C; de Souza, Gezimar D; Rodrigues-Filho, Edson; Glick, James; Vouros, Paul; Carrilho, Emanuel

    2006-01-01

    Mechanisms of fragmentation of hydroxamic siderophores are proposed comparing deuterated and nondeuterated samples. Standard siderophores (e.g. deferoxamine and coprogen) were directly injected into both ion trap and linear quadrupole mass spectrometers with electrospray ionization (ESI). Four and two fragmentation steps were carried out for deferoxamine and coprogen (analyzed by positive and negative ESI, respectively). Deferoxamine cleavages occurred in both peptide and hydroxamic bonds while the coprogen fragmentation pattern is more elaborate, since it contains Fe(III) in its structure.

  16. Simultaneous quantification of multiple urinary naphthalene metabolites by liquid chromatography tandem mass spectrometry.

    PubMed

    Ayala, Daniel C; Morin, Dexter; Buckpitt, Alan R

    2015-01-01

    Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5) and 6.8 (± 5.0) %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs) showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up. PMID:25853821

  17. Determination of triapine, a ribonucleotide reductase inhibitor, in human plasma by liquid chromatography tandem mass spectrometry.

    PubMed

    Feng, Ye; Kunos, Charles A; Xu, Yan

    2015-09-01

    Triapine is an inhibitor of ribonucleotide reductase (RNR). Studies have shown that triapine significantly decreases the activity of RNR and enhanced the radiation-mediated cytotoxicity in cervical and colon cancer. In this work, we have developed and validated a selective and sensitive LC-MS/MS method for the determination of triapine in human plasma. In this method, 2-[(3-fluoro-2-pyridinyl)methylene] hydrazinecarbothioamide (NSC 266749) was used as the internal standard (IS); plasma samples were prepared by deproteinization with acetonitrile; tripaine and the IS were separated on a Waters Xbridge Shield RP18 column (3.5 µm; 2.1 × 50 mm) using a mobile phase containing 25.0% methanol and 75.0% ammonium bicarbonate buffer (10.0 mM, pH 8.50; v/v); column eluate was monitored by positive turbo-ionspray tandem mass spectrometry; and quantitation of triapine was carried out in multiple-reaction-monitoring mode. The method developed had a linear calibration range of 0.250-50.0 ng/mL with correlation coefficient of 0.999 for triapine in human plasma. The IS-normalized recovery and the IS-normalized matrix factor of triapine were 101-104% and 0.89-1.05, respectively. The accuracy expressed as percentage error and precision expressed as coefficient of variation were ≤±6 and ≤8%, respectively. The validated LC-MS/MS method was applied to the measurement of triapine in patient samples from a phase I clinical trial. PMID:25677991

  18. Quantitative determination of sarsasapogenin in rat plasma using liquid chromatography-tandem mass spectrometry.

    PubMed

    Yang, Bo; Liu, Zhirui; Hu, Jing; Lai, Xiaodan; Xia, Peiyuan

    2016-06-01

    Sarsasapogenin, a natural compound from Chinese medical herb Anemarrhena asphodeloides Bge., has recently received a great deal of attention due to its various bioactivities. In this study, an easy and applicable liquid chromatography tandem mass spectrometry method for the quantification of sarsasapogenin in rat plasma was developed. Sample preparation was accomplished through a simple one-step protein precipitation procedure with methanol. Negative electrospray ionization was performed using multiple reactions monitoring (MRM) mode with transitions of m/z 417.4/273.2 for sarsasapogenin, and 415.2/271.4 for diosgenin (internal standard). The calibration curve was linear over the range of 0.5-500ng/mL (r=0.9994), with a lower limit of quantification at 0.5ng/mL. The RSD of intra- and inter-day precision was below 6.41%, and accuracy ranged from 87.60% to 99.20%. The RSD of matrix effect and recovery yield was within ±15% of nominal concentrations and sarsasapogenin was stable during stability tests. This validated method had been successfully applied to the preclinical pharmacokinetic studies of sarsasapogenin in rats. The half-life (t1/2) was (15.1±2.3), (16.1±3.0) and (15.4±3.9) h after single intragastric administration of 25, 50 and 100mg/kg sarsasapogenin, respectively. And it was found that, the area under the plasma concentration versus time curve (AUC0-72h) and the maximum plasma concentration (Cmax) were linearly related to dose. PMID:27107248

  19. [Determination of aniline in water and fish by liquid chromatography-tandem mass spectrometry].

    PubMed

    He, Dechun; Zhao, Bo; Tang, Caiming; Xu, Zhencheng; Zhang, Sukun; Han, Jinglei

    2014-09-01

    A fast analytical method for the determination of aniline in water and fish meat by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. The water sample was mixed with acetonitrile by 4:1 (v/v) and the fish sample was extracted by 2.00 mL acetonitrile for each gram of sample, and then the extracts of water and fish samples were centrifuged at 5,000 r/min for 5 min. The separation was performed on a reversed-phase C18 column using mobile phases of acetonitrile-0.5% (v/v) formic acid aqueous solution (85:15, v/v). Aniline was separated within 3 min. The calibration curve was linear in the range of 0.5-500 pg/L with R2 > 0.999. The limits of detection (LODs) were 0.50 μg/L and 1.00 μg/kg and the limits of quantification (LOQs) were 1.00 μg/L and 2.00 μg/kg for aniline in water and fish meat, respectively. The average recoveries of aniline in water were 93.7% at the spiked level of 40 ng and 86.7% at the spiked level of 400 ng (n = 5). The average recoveries of aniline in fish were 96.8%, 92.6% and 81.8% at the spiked levels of 5, 50 and 500 ng respectively (n = 5). The relative standard deviations were 1.5%-9.2%. Thirteen water samples and twelve fish samples were collected from a reservoir polluted by aniline and the maximum contents found were 1,943. 6 μg/L in water and 60.8 μg/kg in fish. The method is suitable for the determination of aniline residues in water and fish with the characteristics of easy operation, high accuracy and precision.

  20. Simultaneous Quantification of Multiple Urinary Naphthalene Metabolites by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Ayala, Daniel C.; Morin, Dexter; Buckpitt, Alan R.

    2015-01-01

    Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5) and 6.8 (± 5.0) %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs) showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up. PMID:25853821

  1. Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    van Nuijs, Alexander L N; Tarcomnicu, Isabela; Bervoets, Lieven; Blust, Ronny; Jorens, Philippe G; Neels, Hugo; Covaci, Adrian

    2009-10-01

    The simultaneous analysis of nine drugs of abuse (DOAs) and their metabolites (amphetamine, methamphetamine, methylenedioxymethamphetamine, methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, cocaine, benzoylecgonine, ecgonine methyl ester and 6-monoacetylmorphine) in wastewater based on hydrophilic interaction liquid chromatography (HILIC) coupled to tandem mass spectrometry (MS/MS) was optimised and validated. For each analyte, the deuterated analogue was used for quantification. The separation by HILIC showed good performance for all compounds, especially for the hydrophilic compounds, which elute early (amphetamine-like stimulants) or show no retention (ecgonine methyl ester) in reversed-phase liquid chromatography. Sample preparation based on solid-phase extraction was optimised by comparing Oasis HLB and Oasis MCX sorbents for various parameters such as sample pH, amount of sorbent bed and washing solvent. The method was validated for each compound by assessing the following parameters (following International Conference on Harmonisation guidelines): specificity, limit of quantification (LOQ), linearity, accuracy, precision, recovery and matrix effects. LOQs were 2 ng/L for 6-monoacetylmorphine, ecgonine methyl ester and amphetamine and 1 ng/L for the rest of the compounds, corresponding with the lowest point in the calibration curve. Except for 6-monoacetylmorphine, all compounds were detected from 1 to 819 ng/L in influent wastewater samples (n = 12) collected from 11 different wastewater treatment plants across Belgium. The presence of ecgonine methyl ester in wastewater could be demonstrated for the first time. In the future, the new HILIC-MS/MS method will be applied to assess the use of DOAs in Belgium using the "sewage epidemiology" approach. PMID:19685341

  2. Simultaneous quantification of multiple urinary naphthalene metabolites by liquid chromatography tandem mass spectrometry.

    PubMed

    Ayala, Daniel C; Morin, Dexter; Buckpitt, Alan R

    2015-01-01

    Naphthalene is an environmental toxicant to which humans are exposed. Naphthalene causes dose-dependent cytotoxicity to murine airway epithelial cells but a link between exposure and human pulmonary disease has not been established. Naphthalene toxicity in rodents depends on P450 metabolism. Subsequent biotransformation results in urinary elimination of several conjugated metabolites. Glucuronide and sulfate conjugates of naphthols have been used as markers of naphthalene exposure but, as the current studies demonstrate, these assays provide a limited view of the range of metabolites generated from the parent hydrocarbon. Here, we present a liquid chromatography tandem mass spectrometry method for measurement of the glucuronide and sulfate conjugates of 1-naphthol as well as the mercapturic acids and N-acetyl glutathione conjugates from naphthalene epoxide. Standard curves were linear over 2 log orders. On column detection limits varied from 0.91 to 3.4 ng; limits of quantitation from 1.8 to 6.4 ng. The accuracy of measurement of spiked urine standards was -13.1 to + 5.2% of target and intra-day and inter-day variability averaged 7.2 (± 4.5) and 6.8 (± 5.0) %, respectively. Application of the method to urine collected from mice exposed to naphthalene at 15 ppm (4 hrs) showed that glutathione-derived metabolites accounted for 60-70% of the total measured metabolites and sulfate and glucuronide conjugates were eliminated in equal amounts. The method is robust and directly measures several major naphthalene metabolites including those derived from glutathione conjugation of naphthalene epoxide. The assays do not require enzymatic deconjugation, extraction or derivatization thus simplifying sample work up.

  3. Designer psychostimulants in urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Kerrigan, Sarah; Mott, Ashley; Jatzlau, Breanna; Ortiz, Francisco; Perrella, Laura; Martin, Sarah; Bryand, Kelsie

    2014-01-01

    Designer psychostimulants are known by recreational drug users to produce a complex array of adrenergic and hallucinogenic effects. Many of these drugs are not targeted during routine toxicology testing and as a consequence, they are rarely reported. The purpose of this study was to develop a procedure for the detection of 15 psychostimulants in urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS), specifically 2,5-dimethoxy-4-bromophenethylamine (2C-B), 2,5-dimethoxy-4-chlorophenethylamine (2C-C), 2,5-dimethoxy-4-methylphenethylamine (2C-D), 2,5-dimethoxy-4-ethylphenethylamine (2C-E), 2,5-dimethoxyphenethylamine (2C-H), 2,5-dimethoxy-4-iodophenethylamine (2C-I), 2,5-dimethoxy-4-ethylthiophenethylamine (2C-T-2), 2,5-dimethoxy-4-isopropylthiophenethylamine (2C-T-4), 2,5-dimethoxy-4-propylthiophenethylamine (2C-T-7), 2,5-dimethoxy-4-bromoamphetamine (DOB), 2,5-dimethoxy-4-chloroamphetamine (DOC), 2,5-dimethoxy-4-ethylamphetamine (DOET), 2,5-dimethoxy-4-iodoamphetamine (DOI), 2,5-dimethoxy-4-methylamphetamine (DOM), and 4-methylthioamphetamine (4-MTA). Analytical recoveries using solid-phase extraction were 64-92% and the limit of detection was 0.5 ng/mL for all drugs except 2C-B (1 ng/mL). The assay was evaluated in terms of analytical recovery, precision, accuracy, linearity, matrix effect, and interferences. The technique allows for the simultaneous detection of 15 psychostimulants at sub-ng/mL concentrations.

  4. Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Li, J.S.; Chen, M.; Li, Z.C.

    2012-01-01

    A sensitive and reliable method of liquid chromatography–electrospray ionization/tandem mass spectrometry (LC-ESI/MS/ MS) was developed and validated for determining 1,3-dimethylamylamine (1,3-DMAA) and 1,4-dimethylamylamine (1,4-DMAA) in geranium plants (Pelargonium graveolens). The sample was extracted with 0.5 M HCl and purified by liquid-liquid partition with hexane. The parameters for reverse-phase (C18) LC and positive ESI/MS/MS were optimized. The matrix effect, specificity, linearity, precision, accuracy and reproducibility of the method were determined and evaluated. The method was linear over a range of 0.10–10.00 ng/mL examined, with R2 of 0.99 for both 1,3-DMAA and 1,4-DMAA. The recoveries from spiked concentrations between 5.00–40.00 ng/g were 85.1%–104.9% for 1,3-DMAA, with relative standard deviation (RSD) of 2.9%–11.0%, and 82.9%–101.8% for 1,4-DMAA, with RSD of 3.2%–11.7%. The instrument detection limit was 1–2 pg for both DMAAs. The quantification limit was estimated to be 1–2 ng/g for the plant sample. This method was successfully applied to the quantitative determination of 1,3- and 1,4-DMAA in both geranium plant and geranium oil. PMID:22915838

  5. Parallel Reaction Monitoring: A Targeted Experiment Performed Using High Resolution and High Mass Accuracy Mass Spectrometry

    PubMed Central

    Rauniyar, Navin

    2015-01-01

    The parallel reaction monitoring (PRM) assay has emerged as an alternative method of targeted quantification. The PRM assay is performed in a high resolution and high mass accuracy mode on a mass spectrometer. This review presents the features that make PRM a highly specific and selective method for targeted quantification using quadrupole-Orbitrap hybrid instruments. In addition, this review discusses the label-based and label-free methods of quantification that can be performed with the targeted approach. PMID:26633379

  6. Spectral probabilities of top-down tandem mass spectra

    SciTech Connect

    Liu, Xiaowen; Segar, Matthew W.; Li, Shuai Cheng; Kim, Sangtae

    2014-01-24

    In mass spectrometry (MS)-based proteomics, accurate estimation of statistical signicance of peptide and protein identications is desired for determining whether they are actually correct. Probabilistic models, such as the generating function method, have been successfully applied to compute statistical signicance of peptide-spectrum matches (PSMs) in bottom-up MS, but it is limited to PSMs of short peptides without post-translational modications (PTMs). Recently, top-down MS has be- come available in many laboratories, which often identies intact proteins with PTMs. In this paper, we propose an extended generating function (EGF) method for accurately computing statistical signicance of protein- spectrum matches (PrSMs) with PTMs.

  7. Faster SEQUEST Searching for Peptide Identification from Tandem Mass Spectra

    PubMed Central

    Diament, Benjamin; Noble, William Stafford

    2011-01-01

    Computational analysis of mass spectra remains the bottleneck in many proteomics experiments. SEQUEST was one of the earliest software packages to identify peptides from mass spectra by searching a database of known peptides. Though still popular, SEQUEST performs slowly. Crux and TurboSEQUEST have successfully sped up SEQUEST by adding a precomputed index to the search, but the demand for ever-faster peptide identification software continues to grow. Tide, introduced here, is a software program that implements the SEQUEST algorithm for peptide identification and that achieves a dramatic speedup over Crux and SEQUEST. The optimization strategies detailed here employ a combination of algorithmic and software engineering techniques to achieve speeds up to 170 times faster than a recent version of SEQUEST that uses indexing. For example, on a single Xeon CPU, Tide searches 10,000 spectra against a tryptic database of 27,499 C. elegans proteins at a rate of 1,550 spectra per second, which compares favorably with a rate of 8.8 spectra per second for a recent version of SEQUEST with index running on the same hardware. PMID:21761931

  8. Analysis of phospholipids in bio-oils and fats by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Viidanoja, Jyrki

    2015-09-15

    A new, sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method was developed for the analysis of Phospholipids (PLs) in bio-oils and fats. This analysis employs hydrophilic interaction liquid chromatography-scheduled multiple reaction monitoring (HILIC-sMRM) with a ZIC-cHILIC column. Eight PL class selective internal standards (homologs) were used for the semi-quantification of 14 PL classes for the first time. More than 400 scheduled MRMs were used for the measurement of PLs with a run time of 34min. The method's performance was evaluated for vegetable oil, animal fat and algae oil. The averaged within-run precision and between-run precision were ≤10% for all of the PL classes that had a direct homologue as an internal standard. The method accuracy was generally within 80-120% for the tested PL analytes in all three sample matrices.

  9. [Determination of homocysteine by tandem mass spectrometry with chemical ionization].

    PubMed

    Miroshnichenko, I I; Platova, A I; Safarova, T P; Iakovleva, O B

    2014-01-01

    Homocysteine (Hcy) is an intermediate of methionine metabolism. High plasma Hcy concentrations are an independent risk factor for stroke, peripheral vascular disease, deep venous thrombosis, coronary disease, and cognitive deficiency. Apparently, it is a great importance to measure Hcy levels in human blood. A new method for the quantification of Hcy by means of reversed-phase LC/atmospheric pressure chemical ionization mass spectrometry has been developed. The MRM ion transition, m/z 136.0 ® 90.0 was used for Hcy quantification. The limit of detection was 0.4 mM, quantification was performed from 1 mM to 40 mM with coefficient of determination of R2=0,997. The method was applied successfully to Hcy determination in human blood.

  10. On comparison of SimTandem with state-of-the-art peptide identification tools, efficiency of precursor mass filter and dealing with variable modifications.

    PubMed

    Novák, Jiří; Sachsenberg, Timo; Hoksza, David; Skopal, Tomáš; Kohlbacher, Oliver

    2013-11-14

    The similarity search in theoretical mass spectra generated from protein sequence databases is a widely accepted approach for identification of peptides from query mass spectra produced by shotgun proteomics. Growing protein sequence databases and noisy query spectra demand database indexing techniques and better similarity measures for the comparison of theoretical spectra against query spectra. We employ a modification of previously proposed parameterized Hausdorff distance for comparisons of mass spectra. The new distance outperforms the original distance, the angle distance and state-of-the-art peptide identification tools OMSSA and X!Tandem in the number of identified peptides even though the q-value is only 0.001. When a precursor mass filter is used as a database indexing technique, our method outperforms OMSSA in the speed of search. When variable modifications are not searched, the search time is similar to X!Tandem. We show that the precursor mass filter is an efficient database indexing technique for high-accuracy data even though many variable modifications are being searched. We demonstrate that the number of identified peptides is bigger when variable modifications are searched separately by more search runs of a peptide identification engine. Otherwise, the false discovery rates are affected by mixing unmodified and modified spectra together resulting in a lower number of identified peptides. Our method is implemented in the freely available application SimTandem which can be used in the framework TOPP based on OpenMS.

  11. Ion mobility tandem mass spectrometry enhances performance of bottom-up proteomics.

    PubMed

    Helm, Dominic; Vissers, Johannes P C; Hughes, Christopher J; Hahne, Hannes; Ruprecht, Benjamin; Pachl, Fiona; Grzyb, Arkadiusz; Richardson, Keith; Wildgoose, Jason; Maier, Stefan K; Marx, Harald; Wilhelm, Mathias; Becher, Isabelle; Lemeer, Simone; Bantscheff, Marcus; Langridge, James I; Kuster, Bernhard

    2014-12-01

    One of the limiting factors in determining the sensitivity of tandem mass spectrometry using hybrid quadrupole orthogonal acceleration time-of-flight instruments is the duty cycle of the orthogonal ion injection system. As a consequence, only a fraction of the generated fragment ion beam is collected by the time-of-flight analyzer. Here we describe a method utilizing postfragmentation ion mobility spectrometry of peptide fragment ions in conjunction with mobility time synchronized orthogonal ion injection leading to a substantially improved duty cycle and a concomitant improvement in sensitivity of up to 10-fold for bottom-up proteomic experiments. This enabled the identification of 7500 human proteins within 1 day and 8600 phosphorylation sites within 5 h of LC-MS/MS time. The method also proved powerful for multiplexed quantification experiments using tandem mass tags exemplified by the chemoproteomic interaction analysis of histone deacetylases with Trichostatin A.

  12. LESSONS IN DE NOVO PEPTIDE SEQUENCING BY TANDEM MASS SPECTROMETRY

    PubMed Central

    Medzihradszky, Katalin F.; Chalkley, Robert J.

    2015-01-01

    Mass spectrometry has become the method of choice for the qualitative and quantitative characterization of protein mixtures isolated from all kinds of living organisms. The raw data in these studies are MS/MS spectra, usually of peptides produced by proteolytic digestion of a protein. These spectra are “translated” into peptide sequences, normally with the help of various search engines. Data acquisition and interpretation have both been automated, and most researchers look only at the summary of the identifications without ever viewing the underlying raw data used for assignments. Automated analysis of data is essential due to the volume produced. However, being familiar with the finer intricacies of peptide fragmentation processes, and experiencing the difficulties of manual data interpretation allow a researcher to be able to more critically evaluate key results, particularly because there are many known rules of peptide fragmentation that are not incorporated into search engine scoring. Since the most commonly used MS/MS activation method is collision-induced dissociation (CID), in this article we present a brief review of the history of peptide CID analysis. Next, we provide a detailed tutorial on how to determine peptide sequences from CID data. Although the focus of the tutorial is de novo sequencing, the lessons learned and resources supplied are useful for data interpretation in general. PMID:25667941

  13. Fast multi-blind modification search through tandem mass spectrometry.

    PubMed

    Na, Seungjin; Bandeira, Nuno; Paek, Eunok

    2012-04-01

    With great biological interest in post-translational modifications (PTMs), various approaches have been introduced to identify PTMs using MS/MS. Recent developments for PTM identification have focused on an unrestrictive approach that searches MS/MS spectra for all known and possibly even unknown types of PTMs at once. However, the resulting expanded search space requires much longer search time and also increases the number of false positives (incorrect identifications) and false negatives (missed true identifications), thus creating a bottleneck in high throughput analysis. Here we introduce MODa, a novel "multi-blind" spectral alignment algorithm that allows for fast unrestrictive PTM searches with no limitation on the number of modifications per peptide while featuring over an order of magnitude speedup in relation to existing approaches. We demonstrate the sensitivity of MODa on human shotgun proteomics data where it reveals multiple mutations, a wide range of modifications (including glycosylation), and evidence for several putative novel modifications. Based on the reported findings, we argue that the efficiency and sensitivity of MODa make it the first unrestrictive search tool with the potential to fully replace conventional restrictive identification of proteomics mass spectrometry data.

  14. Determination of 129I using tandem accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Elmore, D.; Gove, H. E.; Ferraro, R.; Kilius, L. R.; Lee, H. W.; Chang, K. H.; Beukens, R. P.; Litherland, A. E.; Russo, C. J.; Purser, K. H.; Murrell, M. T.; Finkel, R. C.

    1980-07-01

    Iodine-129, with a half life of 15.7Myr (ref. 1), is one of the longest lived of the cosmogenic radionuclides. Although the primordial supply of 129I is now extinct, 129I is continuously being produced in the atmosphere primarily by cosmic ray reactions on xenon2, in the Earth primarily by spontaneous fission of 238U (ref. 3), and in meteorites and the Moon primarily by proton and neutron induced reactions on Te and Ba (ref. 4). The relatively large quantity of 129I introduced into the environment from the nuclear age may be useful as a tracer in groundwater hydrology5. Fissiogenic 129I in large granite formations (batholiths) could be used to establish the suitability of these sites for long term nuclear waste storage, because groundwater movement would carry away the more soluble iodides and disturb the equilibrium 129I/238U ratio. The concentration of 129I in meteorites can be combined with results for shorter-lived radionuclides to provide information on the constancy of the galactic cosmic ray flux over longer time scales than previously possible and also on the preterrestrial history of meteorites. We have applied the new atom counting technique to 129I analysis with a sensitivity (the minimum number of atoms in the sample required to obtain a quantitative result) of less than 107 atoms of 129I in a 1-mg sample. An AgI standard with a known 129I/127I ratio of 10-11 was determined to +/-10%, and the background contribution from a reagent grade AgI sample gave an upper limit to the ratio of about 3×10-13. We used a time-of-flight measurement to distinguish 129I from the stable 127I ions that were not separated by the mass analysis system. Our results for the meteorites Bruderheim and Dhajala represent the first direct (that is, not inferred6 from radiogenic Xe) determination of 129I in meteorites. A Xe molecular negative ion was discovered but we show that it is not a problem for 129I analysis.

  15. Determination of pesticides in apples by liquid chromatography with electrospray ionization tandem mass spectrometry and estimation of measurement uncertainty.

    PubMed

    Wang, Jian; Wotherspoon, David

    2007-01-01

    A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to determine 90 pesticides in apple samples. MS/MS data acquisition was achieved by applying multiple-reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Matrix-matched standard calibration curves with the use of isotopically labeled standards (or a chemical analog) as internal standards were used to achieve the best accuracy for the method. Both a conventional method validation procedure and a designed experiment were applied to study the accuracy and precision of the method. A compiled computer program that provided a semiautomated procedure for handling a large number of calculations was used to calculate the overall recovery, intermediate precision, and measurement uncertainty (MU). In general, the overall recoveries from samples spiked at levels of 10, 50, and 80 microg/kg, ranged from 60.8 to 121.1%, intermediate precision was <10%, and MUs were <30%. Poor accuracy and/or repeatability was observed for pyridate and etofenprox. The method limits of detection based on a signal-to-noise ratio of >3 were usually <1 microg/kg (ppb), except those for aldicarb sulfoxide and pyridaphenthion, which were about 5 microg/kg.

  16. Rapid identification of C21 steroidal saponins in Cynanchum versicolor Bunge by electrospray ionization multi-stage tandem mass spectrometry and liquid chromatography/tandem mass spectrometry.

    PubMed

    Zheng, Zhaoguang; Zhang, Weidong; Kong, Lingyi; Liang, Mingjin; Li, Huiliang; Lin, Min; Liu, Runhui; Zhang, Chuan

    2007-01-01

    Electrospray ionization multi-stage tandem mass spectrometry (ESI-MSn) and liquid chromatography coupled with on-line electrospray ionization tandem mass spectrometry (LC/ESI-MSn) were performed to elucidate the clearage rule of nine investigated C21 steroidal saponins and identify them in the saponin fraction of 90% ethanolic extracts from the root and rhizome of Cynanchum versicolor Bunge. The fragments of C21 steroidal saponins in positive and negative ESI-MSn were used to deduce their mass spectral fragmentation mechanisms, and their structures were further confirmed by ESI-MSn in positive mode. The MSn spectra of the [M+Na]+ ions for saponins provided a wealth of structural information on glycosidic bond cleavage, which allowed a straightforward interpretation of spectra, with respect to the identifications of features such as the sequences of sugars attached to saponins and sugar type. By using LC/ESI-MSn, nine C21 steroidal saponins were detected in the saponin fraction of C. versicolor, and an isomer of atratoglaucoside A was elucidated simultaneously. All nine compounds showed an abundant ion for the loss of 46 Da (HCOOH) from [M+Na]+. The losses of monosaccharide sequences and aglycone as neutral fragmentation from [M+Na-HCOOH]+ were also acquired as the characteristic ions of these C21 steroidal saponins. It provided important information on monosaccharide sequences and in particular on sugar types and could be used to identify and elucidate other C21 steroidal saponins. These studies allowed us to rapidly identify C21 steroidal saponins from Radix cynanchi atrati. It is indicated that the described method had wide applicability to rapidly screen and provide structural confirmation on C21 steroidal saponins in crude materials.

  17. High-accuracy mass measurements of neutron-rich Kr isotopes

    SciTech Connect

    Delahaye, P.; Kellerbauer, A.; Audi, G.; Lunney, D.; Blaum, K.; George, S.; Carrel, F.; Herfurth, F.; Yazidjian, C.; Herlert, A.; Schweikhard, L.; Kluge, H.-J.

    2006-09-15

    The atomic masses of the neutron-rich krypton isotopes {sup 84,86-95}Kr have been determined with the tandem Penning trap mass spectrometer ISOLTRAP with uncertainties ranging from 20 to 220 ppb. The masses of the short-lived isotopes {sup 94}Kr and {sup 95}Kr were measured for the first time. The masses of the radioactive nuclides {sup 89}Kr and {sup 91}Kr disagree by 4 and 6 standard deviations, respectively, from the present Atomic-Mass Evaluation database. The resulting modification of the mass surface with respect to the two-neutron separation energies as well as implications for mass models and stellar nucleosynthesis are discussed.

  18. Correction: Synergism between genome sequencing, tandem mass spectrometry and bio-inspired synthesis reveals insights into nocardioazine B biogenesis.

    PubMed

    Alqahtani, Norah; Porwal, Suheel K; James, Elle D; Bis, Dana M; Karty, Jonathan A; Lane, Amy L; Viswanathan, Rajesh

    2015-09-21

    Correction for 'Synergism between genome sequencing, tandem mass spectrometry and bio-inspired synthesis reveals insights into nocardioazine B biogenesis' by Norah Alqahtani et al., Org. Biomol. Chem., 2015, 13, 7177-7192.

  19. Collision-induced dissociation pathways of anabolic steroids by electrospray ionization tandem mass spectrometry.

    PubMed

    Guan, Fuyu; Soma, Lawrence R; Luo, Yi; Uboh, Cornelius E; Peterman, Scott

    2006-04-01

    Anabolic steroids are structurally similar compounds, and their product-ion spectra obtained by tandem mass spectrometry under electrospray ionization conditions are quite difficult to interpret because of poly-ring structures and lack of a charge-retaining center in their chemical structures. In the present study, the fragmentation of nine anabolic steroids of interest to the racing industry was investigated by using triple quadrupole mass spectrometer, Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer, and a linear ion trap instrument. With the aid of an expert system software (Mass Frontier version 3.0), accurate mass measurements, and multiple stage tandem mass spectrometric (MS(n)) experiments, fragmentation pathways were elucidated for boldenone, methandrostenolone, tetrahydrogestrinone (THG), trenbolone, normethandrolone and mibolerone. Small differences in the chemical structures of the steroids, such as an additional double-bond or a methyl group, result in significantly different fragmentation pathways. The fragmentation pathways proposed in this paper allow interpretation of major product ions of other anabolic steroids reported by other researchers in a recent publication. The proposed fragmentation pathways are helpful for characterization of new steroids. The approach used in this study for elucidation of the fragmentation pathways is helpful in interpretation of complicated product-ion spectra of other compounds, drugs and their metabolites. PMID:16488153

  20. Improved characterization of tomato polyphenols using liquid chromatography/electrospray ionization linear ion trap quadrupole Orbitrap mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry.

    PubMed

    Vallverdú-Queralt, Anna; Jáuregui, Olga; Medina-Remón, Alexander; Andrés-Lacueva, Cristina; Lamuela-Raventós, Rosa M

    2010-10-30

    Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole-Orbitrap-mass spectrometry (LC/ESI-LTQ-Orbitrap-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high-resolution system (LTQ-Orbitrap) using accurate mass measurements in MS, MS(2) and MS(3) modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples.

  1. Advanced laser architecture for the two-step laser tandem mass spectrometer

    NASA Astrophysics Data System (ADS)

    Fahey, Molly E.; Li, Steven X.; Yu, Anthony W.; Getty, Stephanie; Grubisic, Andrej; Brinckerhoff, William

    2016-05-01

    Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. We have made significant progress in the laser desorption/ionization mass spectrometry area with advancement in the two-step laser tandem mass spectrometer (L2MS) instrument to deconvolve complex organic signatures. In this paper we will describe our development effort on a new laser architecture for the L2MS instrument. The laser provides two discrete mid-infrared and ultraviolet wavelengths on a single laser bench with a straightforward path toward space deployment.

  2. Electrospray Ionization Tandem Mass Spectrometry (ESI-MS/MS)-Based Shotgun Lipidomics

    SciTech Connect

    Mezengie, Giorgis I.

    2011-01-11

    In the past decade, many new strategies for mass spectrometry (MS)-based analyses of lipids have been developed. Lipidomics is one of the most promising research fields to emerge as a result of these advances in MS. Currently, mass spectrometric analysis of lipids involves two complementary approaches: direct infusion (shotgun lipidomics) and liquid chromatography coupled to MS. In this chapter, I will demonstrate the approach of shotgun lipidomics using electrospray ionization tandem MS for the analysis of lipid molecular species directly from crude biological extracts of tissue or fluids.

  3. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    SciTech Connect

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A; Van Berkel, Gary J

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  4. Determination of rutin in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and application to pharmacokinetic study.

    PubMed

    Chen, Mengchun; Zhang, Xiaoqian; Wang, Hao; Lin, Baoli; Wang, Shuanghu; Hu, Guoxin

    2015-04-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91→302.98 and m/z 271.2→155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study.

  5. Simultaneous determination of phenolic compounds in Equisetum palustre L. by ultra high performance liquid chromatography with tandem mass spectrometry combined with matrix solid-phase dispersion extraction.

    PubMed

    Wei, Zuofu; Pan, Youzhi; Li, Lu; Huang, Yuyang; Qi, Xiaolin; Luo, Meng; Zu, Yuangang; Fu, Yujie

    2014-11-01

    A method based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid-phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid-phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound-assisted extraction, the proposed matrix solid-phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices.

  6. Study of sodium tanshinone II A sulfonate tissue distribution in rat by liquid chromatography/tandem mass spectrometry.

    PubMed

    He, Tingting; Zou, Qiaogen; Feng, Zhenbin; Zhang, Zunjian

    2010-01-01

    A rapid and sensitive method based on liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and fully validated for the quantitative determination of sodium tanshinone IIA sulfonate (STS, sodium (1,6,6-trimethyl-10,11-dioxo-7,8,9-trihydrophenanthro[1,2-b]furan)-yl-2-sulfonate) in rat biosamples including plasma and different tissues using sodium tanshinone I sulfonate (sodium (1,6-dimethyl-10,11-dioxo-phenanthro[1,2-b]furan)-yl-2-sulfonate) as internal standard. Simple protein precipitation by acetonitrile was utilized for extracting STS from the rat biosamples. Chromatographic separation of the sample matrix from the analyte and the internal standard was performed using a commercially available analytical column with a mobile phase consisting of methanol-5 mmoL/L ammonia acetate (70:30, v/v) at a flow rate of 0.2 mL/min. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source and operated in the negative-ion mode. The intra- and inter-day precisions (RSD%) and deviations of the assay accuracies were within 10.0% for STS. The extraction recovery of STS was more than 86.5%. The limit of detection (LOD) of STS was 1.0 ng/mL. The method was successfully applied to the tissue distribution study of STS intravenously administered to healthy Sprague-Dawley rats. The tissue distribution results showed that liver, kidney, lung, small intestine and duodenum were the major distribution tissues of STS in rats, and that STS had difficulty in crossing the blood-brain barrier. After 24 h, STS could be detected only in the kidney, stomach and small intestine, indicating that there was no long-term accumulation of STS in rat. PMID:21175038

  7. Simultaneous quantification of atenolol and chlorthalidone in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Shah, Jaivik V; Patel, Daxesh P; Shah, Priyanka A; Sanyal, Mallika; Shrivastav, Pranav S

    2016-02-01

    A simple, sensitive and reproducible ultra-performance liquid chromatography-tandem mass spectrometry method has been developed for the simultaneous determination of atenolol, a β-adrenergic receptor-blocker and chlorthalidone, a monosulfonamyl diuretic in human plasma, using atenolol-d7 and chlorthalidone-d4 as the internal standards (ISs). Following solid-phase extraction on Phenomenex Strata-X cartridges using 100 μL human plasma sample, the analytes and ISs were separated on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 µm) column using a mobile phase consisting of 0.1% formic acid-acetonitrile (25:75, v/v). A tandem mass spectrometer equipped with electrospray ionization was used as a detector in the positive ionization mode for both analytes. The linear concentration range was established as 0.50-500 ng/mL for atenolol and 0.25-150 ng/mL for chlorthalidone. Extraction recoveries were within 95-103% and ion suppression/enhancement, expressed as IS-normalized matrix factors, ranged from 0.95 to 1.06 for both the analytes. Intra-batch and inter-batch precision (CV) and accuracy values were 2.37-5.91 and 96.1-103.2%, respectively. Stability of analytes in plasma was evaluated under different conditions, such as bench-top, freeze-thaw, dry and wet extract and long-term. The developed method was superior to the existing methods for the simultaneous determination of atenolol and chlorthalidone in human plasma with respect to the sensitivity, chromatographic analysis time and plasma volume for processing. Further, it was successfully applied to support a bioequivalence study of 50 mg atenolol + 12.5 mg chlorthalidone in 28 healthy Indian subjects.

  8. Rapid chiral separation of racemic cetirizine in human plasma using subcritical fluid chromatography-tandem mass spectrometry.

    PubMed

    Eom, Han Young; Kang, Myunghee; Kang, Seung Woo; Kim, Unyong; Suh, Joon Hyuk; Kim, Junghyun; Cho, Hyun-Deok; Jung, Yura; Yang, Dong-Hyug; Han, Sang Beom

    2016-01-01

    A method for fast chiral separation of cetirizine and quantitation of levocetirizine in human plasma using subcritical fluid chromatography with tandem mass spectrometry was developed and validated. The chromatographic separation was performed using a Chiralpak IE column (2.1 mm×150 mm, 5 μm) with an isocratic elution of CO2/organic modifier (55/45, v/v) at a flow rate of 0.85 mL/min. The organic modifier was composed of water/methanol (5/95, v/v). The makeup flow was optimized at water/methanol (10/90, v/v) and 0.2 mL/min. The most influential parameters on the separation of cetirizine affecting resolution, retention time and sensitivity were selected by fractional factorial design. The 3 selected factors were optimized by response surface methodology. Tandem mass spectrometry was used at electrospray ionization, positive ion mode, and multiple-reaction monitoring mode. Isotope-labeled cetirizine-d4 was used as the internal standard. The sample preparation of human plasma was conducted by solid phase extraction of hydrophilic-lipophilic balance (HLB) type. The developed method was validated for selectivity, linearity, precision, accuracy, recovery, limit of quantitation (LOQ), and limit of detection (LOD). The real human plasma samples were analyzed and the pharmacokinetic results were compared with results of previous research. The developed method was found to be reliable based on the similarity between the results of the current and previous methods. The chiral separation for cetirizine and economic feasibility were compared with those of previous studies using normal phase-HPLC or reversed phase-HPLC. The established analytical method could be successfully applied to pharmacokinetic study with reduction in the analysis time and costs. PMID:26440285

  9. Simultaneous determination of buprenorphine, norbuprenorphine and naloxone in human plasma by liquid chromatography/tandem mass spectrometry.

    PubMed

    Liu, Yongzhen; Li, Xiaohua; Xu, Allan; Nasser, Azmi F; Heidbreder, Christian

    2016-02-20

    A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for simultaneous quantification of naloxone, buprenorphine and its metabolite norbuprenorphine in human plasma. Human plasma samples were extracted using a single step liquid-liquid extraction, and then separated on an Imtakt Unison UK-C18 column (2.1×50mm, 3μm) using alkaline mobile phases with gradient elution. All of the analytes were detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation, precision, accuracy, recoveries and stability were determined. The linear range was 20-10000pg/mL for buprenorphine and norbuprenorphine; and 1-500pg/mL for naloxone. The correlation coefficient (R(2)) values for all three analytes were ≥0.995. The precision and accuracy for intra-day and inter-day were <11.0%. The recoveries were >63% and matrix effects were tracked by the deuterated internal standards (IS) with the IS-normalized matrix factor ranging from 0.96 to 1.33 for all three analytes. The validated method was successfully applied in a clinical pharmacokinetic study with low dose administration of sublingual buprenorphine and naloxone.

  10. Simultaneous determination of buprenorphine, norbuprenorphine and naloxone in human plasma by liquid chromatography/tandem mass spectrometry.

    PubMed

    Liu, Yongzhen; Li, Xiaohua; Xu, Allan; Nasser, Azmi F; Heidbreder, Christian

    2016-02-20

    A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for simultaneous quantification of naloxone, buprenorphine and its metabolite norbuprenorphine in human plasma. Human plasma samples were extracted using a single step liquid-liquid extraction, and then separated on an Imtakt Unison UK-C18 column (2.1×50mm, 3μm) using alkaline mobile phases with gradient elution. All of the analytes were detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation, precision, accuracy, recoveries and stability were determined. The linear range was 20-10000pg/mL for buprenorphine and norbuprenorphine; and 1-500pg/mL for naloxone. The correlation coefficient (R(2)) values for all three analytes were ≥0.995. The precision and accuracy for intra-day and inter-day were <11.0%. The recoveries were >63% and matrix effects were tracked by the deuterated internal standards (IS) with the IS-normalized matrix factor ranging from 0.96 to 1.33 for all three analytes. The validated method was successfully applied in a clinical pharmacokinetic study with low dose administration of sublingual buprenorphine and naloxone. PMID:26730511

  11. MyriMatch: highly accurate tandem mass spectral peptide identification by multivariate hypergeometric analysis

    PubMed Central

    Tabb, David L.; Fernando, Christopher G.; Chambers, Matthew C.

    2008-01-01

    Shotgun proteomics experiments are dependent upon database search engines to identify peptides from tandem mass spectra. Many of these algorithms score potential identifications by evaluating the number of fragment ions matched between each peptide sequence and an observed spectrum. These systems, however, generally do not distinguish between matching an intense peak and matching a minor peak. We have developed a statistical model to score peptide matches that is based upon the multivariate hypergeometric distribution. This scorer, part of the “MyriMatch” database search engine, places greater emphasis on matching intense peaks. The probability that the best match for each spectrum has occurred by random chance can be employed to separate correct matches from random ones. We evaluated this software on data sets from three different laboratories employing three different ion trap instruments. Employing a novel system for testing discrimination, we demonstrate that stratifying peaks into multiple intensity classes improves the discrimination of scoring. We compare MyriMatch results to those of Sequest and X!Tandem, revealing that it is capable of higher discrimination than either of these algorithms. When minimal peak filtering is employed, performance plummets for a scoring model that does not stratify matched peaks by intensity. On the other hand, we find that MyriMatch discrimination improves as more peaks are retained in each spectrum. MyriMatch also scales well to tandem mass spectra from high-resolution mass analyzers. These findings may indicate limitations for existing database search scorers that count matched peaks without differentiating them by intensity. This software and source code is available under Mozilla Public License at this URL: http://www.mc.vanderbilt.edu/msrc/bioinformatics/. PMID:17269722

  12. De Novo Correction of Mass Measurement Error in Low Resolution Tandem MS Spectra for Shotgun Proteomics

    NASA Astrophysics Data System (ADS)

    Egertson, Jarrett D.; Eng, Jimmy K.; Bereman, Michael S.; Hsieh, Edward J.; Merrihew, Gennifer E.; MacCoss, Michael J.

    2012-12-01

    We report an algorithm designed for the calibration of low resolution peptide mass spectra. Our algorithm is implemented in a program called FineTune, which corrects systematic mass measurement error in 1 min, with no input required besides the mass spectra themselves. The mass measurement accuracy for a set of spectra collected on an LTQ-Velos improved 20-fold from -0.1776 ± 0.0010 m/z to 0.0078 ± 0.0006 m/z after calibration (avg ± 95 % confidence interval). The precision in mass measurement was improved due to the correction of non-linear variation in mass measurement accuracy across the m/z range.

  13. High-throughput multiclass method for antibiotic residue analysis by liquid chromatography-tandem mass spectrometry.

    PubMed

    Chico, J; Rúbies, A; Centrich, F; Companyó, R; Prat, M D; Granados, M

    2008-12-12

    A simple and rapid method has been developed for the residue analysis of 39 antibiotics (tetracyclines, quinolones, penicillins, sulfonamides and macrolides) in foodstuffs of animal origin. The method combines an effective extraction technique, which uses water-methanol as extracting solvent, with ultra-high-pressure liquid chromatography-tandem mass spectrometry, allowing both confirmation and quantification in a single chromatographic run. The multiresidue method has been validated in chicken muscle matrix according to European Union Decision 2002/657/EC. It has been implemented as a routine method in a Public Health Laboratory, instead of the five plates test and LC methods previously used.

  14. Determination of amphetamine and methamphetamine in umbilical cord using liquid chromatography-tandem mass spectrometry.

    PubMed

    Jones, Joseph; Rios, Rosemarie; Jones, Mary; Lewis, Douglas; Plate, Charles

    2009-11-01

    The use of meconium as a drug-screening matrix for newborns has been the gold standard of care for the past two decades. A recent study using matched pairs of meconium and umbilical cord demonstrated a high degree of agreement. The use of liquid chromatography-tandem mass spectrometry as a means to confirm amphetamines presumptive positive umbilical cord specimens for amphetamine and methamphetamine is described here for the first time. The limit of detection for both compounds was 0.2 ng/g. The limit of quantitation for both compounds was 0.6 ng/g. The assay was linear for both compounds up to 100 ng/g.

  15. High-throughput multiclass method for antibiotic residue analysis by liquid chromatography-tandem mass spectrometry.

    PubMed

    Chico, J; Rúbies, A; Centrich, F; Companyó, R; Prat, M D; Granados, M

    2008-12-12

    A simple and rapid method has been developed for the residue analysis of 39 antibiotics (tetracyclines, quinolones, penicillins, sulfonamides and macrolides) in foodstuffs of animal origin. The method combines an effective extraction technique, which uses water-methanol as extracting solvent, with ultra-high-pressure liquid chromatography-tandem mass spectrometry, allowing both confirmation and quantification in a single chromatographic run. The multiresidue method has been validated in chicken muscle matrix according to European Union Decision 2002/657/EC. It has been implemented as a routine method in a Public Health Laboratory, instead of the five plates test and LC methods previously used. PMID:18992888

  16. Identification of compounds in wine by HPLC-tandem mass spectrometry.

    PubMed

    Bevilacqua, Lucio; Buiarelli, Francesca; Coccioli, Franco; Jasionowska, Renata

    2004-01-01

    In this work several compounds were detected in wines by HPLC-tandem mass spectrometry. In particular cinnamic and benzoic acids, tyrosol, apigenin-7-glucoside and luteolin-7-glucoside were identified and quantified in Italian wines. Red wines show bigger amount of cinnamic and benzoic acids than white wines. tyrosol is in bigger amount with respect to two flavones: luteolin-7-glucoside and apigenin-7-glucoside. These last two flavones are only in some wine, but it can be important to detect the presence of different substances in small amount to be able to characterize a wine.

  17. Separation and analysis of dimethylaniline isomers by supercritical fluid chromatography--electrospray ionization tandem mass spectrometry.

    PubMed

    Strife, Robert J; Mangels, Michele L; Skare, Julie A

    2009-10-01

    The assessment of human exposure to specific isomers of dimethylanilines (DMA's) is of interest for the evaluation of potential exposure-health outcome relationships. Improved analytical methods will help in identifying the environmental sources of such exposures. The separation of all six DMA isomers by supercritical fluid chromatography (SFC), without derivatization, is reported within. Further, the combination of SFC with electrospray ionization/tandem mass spectrometry provides selective detection in crude extracts of spiked (40 ppb of 3,5-dimethylaniline) raw materials. The raw materials chosen for analysis are commonly used in the manufacture of consumer hair-dye products.

  18. Identification of compounds in wine by HPLC-tandem mass spectrometry.

    PubMed

    Bevilacqua, Lucio; Buiarelli, Francesca; Coccioli, Franco; Jasionowska, Renata

    2004-01-01

    In this work several compounds were detected in wines by HPLC-tandem mass spectrometry. In particular cinnamic and benzoic acids, tyrosol, apigenin-7-glucoside and luteolin-7-glucoside were identified and quantified in Italian wines. Red wines show bigger amount of cinnamic and benzoic acids than white wines. tyrosol is in bigger amount with respect to two flavones: luteolin-7-glucoside and apigenin-7-glucoside. These last two flavones are only in some wine, but it can be important to detect the presence of different substances in small amount to be able to characterize a wine. PMID:15506618

  19. Automated Lipid A Structure Assignment from Hierarchical Tandem Mass Spectrometry Data

    NASA Astrophysics Data System (ADS)

    Ting, Ying S.; Shaffer, Scott A.; Jones, Jace W.; Ng, Wailap V.; Ernst, Robert K.; Goodlett, David R.

    2011-05-01

    Infusion-based electrospray ionization (ESI) coupled to multiple-stage tandem mass spectrometry (MS n ) is a standard methodology for investigating lipid A structural diversity (Shaffer et al. J. Am. Soc. Mass. Spectrom. 18(6), 1080-1092, 2007). Annotation of these MS n spectra, however, has remained a manual, expert-driven process. In order to keep up with the data acquisition rates of modern instruments, we devised a computational method to annotate lipid A MS n spectra rapidly and automatically, which we refer to as hierarchical tandem mass spectrometry (HiTMS) algorithm. As a first-pass tool, HiTMS aids expert interpretation of lipid A MS n data by providing the analyst with a set of candidate structures that may then be confirmed or rejected. HiTMS deciphers the signature ions (e.g., A-, Y-, and Z-type ions) and neutral losses of MS n spectra using a species-specific library based on general prior structural knowledge of the given lipid A species under investigation. Candidates are selected by calculating the correlation between theoretical and acquired MS n spectra. At a false discovery rate of less than 0.01, HiTMS correctly assigned 85% of the structures in a library of 133 manually annotated Francisella tularensis subspecies novicida lipid A structures. Additionally, HiTMS correctly assigned 85% of the structures in a smaller library of lipid A species from Yersinia pestis demonstrating that it may be used across species.

  20. Versatile online-offline engine for automated acquisition of high-resolution tandem mass spectra.

    PubMed

    Wenger, Craig D; Boyne, Michael T; Ferguson, Jonathan T; Robinson, Dana E; Kelleher, Neil L

    2008-11-01

    For automated production of tandem mass spectrometric data for proteins and peptides >3 kDa at >50 000 resolution, a dual online-offline approach is presented here that improves upon standard liquid chromatography-tandem mass spectrometry (LC-MS/MS) strategies. An integrated hardware and software infrastructure analyzes online LC-MS data and intelligently determines which targets to interrogate offline using a posteriori knowledge such as prior observation, identification, and degree of characterization. This platform represents a way to implement accurate mass inclusion and exclusion lists in the context of a proteome project, automating collection of high-resolution MS/MS data that cannot currently be acquired on a chromatographic time scale at equivalent spectral quality. For intact proteins from an acid extract of human nuclei fractionated by reversed-phase liquid chromatography (RPLC), the automated offline system generated 57 successful identifications of protein forms arising from 30 distinct genes, a substantial improvement over online LC-MS/MS using the same 12 T LTQ FT Ultra instrument. Analysis of human nuclei subjected to a shotgun Lys-C digest using the same RPLC/automated offline sampling identified 147 unique peptides containing 29 co- and post-translational modifications. Expectation values ranged from 10 (-5) to 10 (-99), allowing routine multiplexed identifications. PMID:18841935

  1. Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

    PubMed

    Hu, Bin; Peng, Xuejiao; Yang, Shuiping; Gu, Haiwei; Chen, Huanwen; Huan, Yanfu; Zhang, Tingting; Qiao, Xiaolin

    2010-02-01

    Without any sample pretreatment, effervescent beverage fluids were manually sprayed into the primary ion plume created by using a nanoelectrospray ionization source for direct ionization, and the analyte ions of interest were guided into an ion trap mass spectrometer for tandem mass analysis. Functional ingredients (e.g., vitamins, taurine, and caffeine, etc.) and spiked impurity (e.g., cocaine) in various beverages, such as Red Bull energy drink, Coco-cola, and Pepsi samples were rapidly identified within 1.5 s. The limit of detection was found to be 7-15 fg (S/N = 3) for cocaine in different samples using the characteristic fragment (m/z 150) observed in the MS(3) experiments. Typical relative standard deviation and recovery of this method were 6.9%-8.6% and 104%-108% for direct analysis of three actual samples, showing that nanoextractive electrospray ionization tandem mass spectrometry is a useful technique for fast screening cocaine presence in beverages. PMID:19939702

  2. Gas Chromatography/Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometry for Fingerprinting the Macondo Oil Spill.

    PubMed

    Lobodin, Vladislav V; Maksimova, Ekaterina V; Rodgers, Ryan P

    2016-07-01

    We report the first application of a new mass spectrometry technique (gas chromatography combined to atmospheric pressure chemical ionization tandem mass spectrometry, GC/APCI-MS/MS) for fingerprinting a crude oil and environmental samples from the largest accidental marine oil spill in history (the Macondo oil spill, the Gulf of Mexico, 2010). The fingerprinting of the oil spill is based on a trace analysis of petroleum biomarkers (steranes, diasteranes, and pentacyclic triterpanes) naturally occurring in crude oil. GC/APCI enables soft ionization of petroleum compounds that form abundant molecular ions without (or little) fragmentation. The ability to operate the instrument simultaneously in several tandem mass spectrometry (MS/MS) modes (e.g., full scan, product ion scan, reaction monitoring) significantly improves structural information content and sensitivity of analysis. For fingerprinting the oil spill, we constructed diagrams and conducted correlation studies that measure the similarity between environmental samples and enable us to differentiate the Macondo oil spill from other sources. PMID:27281271

  3. Improving quantitative precision and throughput by reducing calibrator use in liquid chromatography-tandem mass spectrometry.

    PubMed

    Rule, Geoffrey S; Rockwood, Alan L

    2016-05-01

    To improve efficiency in our mass spectrometry laboratories we have made efforts to reduce the number of calibration standards utilized for quantitation over time. We often analyze three or more batches of 96 samples per day, on a single instrument, for a number of assays. With a conventional calibration scheme at six concentration levels this amounts to more than 5000 calibration points per year. Modern LC-tandem mass spectrometric instrumentation is extremely rugged however, and isotopically labelled internal standards are widely available. This made us consider whether alternative calibration strategies could be utilized to reduce the number of calibration standards analyzed while still retaining high precision and accurate quantitation. Here we demonstrate how, by utilizing a single calibration point in each sample batch, and using the resulting response factor (RF) to update an existing, historical response factor (HRF), we are able to obtain improved precision over a conventional multipoint calibration approach, as judged by quality control samples. The laboratory component of this study was conducted with an existing LC tandem mass spectrometric method for three androgen analytes in our production laboratory. Using examples from both simulated and laboratory data we illustrate several aspects of our single point alternative calibration strategy and compare it with a conventional, multipoint calibration approach. We conclude that both the cost and burden of preparing multiple calibration standards with every batch of samples can be reduced while at the same time maintaining, or even improving, analytical quality. PMID:27086099

  4. Analysis of acetamiprid in vegetables using gas chromatography-tandem mass spectrometry.

    PubMed

    Mateu-Sánchez, Manuel; Moreno, Mercedes; Arrebola, F Javier; Martínez Vidal, José Luis

    2003-05-01

    A new analytical method has been validated for determining the insecticide acetamiprid in vegetables using gas chromatography (OC) and different mass spectrometric detection techniques, such as full-scan mass spectrometry (MS), and tandem mass spectrometry (MS/MS). For this purpose, a previous extraction of the vegetable sample was carried out with ethyl acetate. In GC-MS/MS, the lowest detectable concentration was 0.001 mg kg(-1), the average recovery rates at various fortification levels (0.015 and 0.030 mg kg(-1)) ranged between 82.4 and 85.7% and the relative standard deviations were lower than 12.2% in all cases. PMID:12769368

  5. Application of dual tree complex wavelet transform in tandem mass spectrometry.

    PubMed

    Murugesan, Selvaraaju; Tay, David B H; Cooke, Ira; Faou, Pierre

    2015-08-01

    Mass Spectrometry (MS) is a widely used technique in molecular biology for high throughput identification and sequencing of peptides (and proteins). Tandem mass spectrometry (MS/MS) is a specialised mass spectrometry technique whereby the sequence of peptides can be determined. Preprocessing of the MS/MS data is indispensable before performing any statistical analysis on the data. In this work, preprocessing of MS/MS data is proposed based on the Dual Tree Complex Wavelet Transform (DTCWT) using almost symmetric Hilbert pair of wavelets. After the preprocessing step, the identification of peptides is done using the database search approach. The performance of the proposed preprocessing technique is evaluated by comparing its performance against Discrete Wavelet Transform (DWT) and Stationary Wavelet Transform (SWT). The preprocessing performed using DTCWT identified more peptides compared to DWT and SWT.

  6. In Silico Identification Software (ISIS): A Machine Learning Approach to Tandem Mass Spectral Identification of Lipids

    SciTech Connect

    Kangas, Lars J.; Metz, Thomas O.; Isaac, Georgis; Schrom, Brian T.; Ginovska-Pangovska, Bojana; Wang, Luning; Tan, Li; Lewis, Robert R.; Miller, John H.

    2012-05-15

    Liquid chromatography-mass spectrometry-based metabolomics has gained importance in the life sciences, yet it is not supported by software tools for high throughput identification of metabolites based on their fragmentation spectra. An algorithm (ISIS: in silico identification software) and its implementation are presented and show great promise in generating in silico spectra of lipids for the purpose of structural identification. Instead of using chemical reaction rate equations or rules-based fragmentation libraries, the algorithm uses machine learning to find accurate bond cleavage rates in a mass spectrometer employing collision-induced dissocia-tion tandem mass spectrometry. A preliminary test of the algorithm with 45 lipids from a subset of lipid classes shows both high sensitivity and specificity.

  7. Atmospheric pressure ionization-tandem mass spectrometry of the phenicol drug family.

    PubMed

    Alechaga, Élida; Moyano, Encarnación; Galceran, M Teresa

    2013-11-01

    In this work, the mass spectrometry behaviour of the veterinary drug family of phenicols, including chloramphenicol (CAP) and its related compounds thiamphenicol (TAP), florfenicol (FF) and FF amine (FFA), was studied. Several atmospheric pressure ionization sources, electrospray (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization were compared. In all atmospheric pressure ionization sources, CAP, TAP and FF were ionized in both positive and negative modes; while for the metabolite FFA, only positive ionization was possible. In general, in positive mode, [M + H](+) dominated the mass spectrum for FFA, while the other compounds, CAP, TAP and FF, with lower proton affinity showed intense adducts with species present in the mobile phase. In negative mode, ESI and atmospheric pressure photoionization showed the deprotonated molecule [M-H](-), while atmospheric pressure chemical ionization provided the radical molecular ion by electron capture. All these ions were characterized by tandem mass spectrometry using the combined information obtained by multistage mass spectrometry and high-resolution mass spectrometry in a quadrupole-Orbitrap instrument. In general, the fragmentation occurred via cyclization and losses or fragmentation of the N-(alkyl)acetamide group, and common fragmentation pathways were established for this family of compounds. A new chemical structure for the product ion at m/z 257 for CAP, on the basis of the MS(3) and MS(4) spectra is proposed. Thermally assisted ESI and selected reaction monitoring are proposed for the determination of these compounds by ultra high-performance liquid chromatography coupled to tandem mass spectrometry, achieving instrumental detection limits down to 0.1 pg.

  8. Design and performance of an instrument for electron impact tandem mass spectrometry and action spectroscopy of mass/charge selected macromolecular ions stored in RF ion trap*

    NASA Astrophysics Data System (ADS)

    Ranković, Milos Lj.; Giuliani, Alexandre; Milosavljević, Aleksandar R.

    2016-06-01

    A new apparatus was designed, coupling an electron gun with a linear quadrupole ion trap mass spectrometer, to perform m/ z (mass over charge) selected ion activation by electron impact for tandem mass spectrometry and action spectroscopy. We present in detail electron tracing simulations of a 300 eV electron beam inside the ion trap, design of the mechanical parts, electron optics and electronic circuits used in the experiment. We also report examples of electron impact activation tandem mass spectra for Ubiquitin protein, Substance P and Melittin peptides, at incident electron energies in the range from 280 eV to 300 eV.

  9. Simultaneous quantitation of paracetamol, caffeine, pseudoephedrine, chlorpheniramine and cloperastine in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Hao; Zhang, Chao; Wang, Jiang; Jiang, Yao; Fawcett, J Paul; Gu, Jingkai

    2010-02-01

    A rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous quantitation of paracetamol, caffeine, pseudoephedrine, chlorpheniramine and cloperastine in human plasma has been developed and validated. After sample preparation by liquid-liquid extraction, the analytes and internal standard (diphenhydramine) were analyzed by reversed-phase HPLC on a Venusil Mp-C(18) column (50mmx4.6mm, 5microm) using formic acid:10mM ammonium acetate:methanol (1:40:60, v/v/v) as mobile phase in a run time of 2.6min. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode. The method was linear for all analytes over the following concentration (ng/ml) ranges: paracetamol 5.0-2000; caffeine 10-4000; pseudoephedrine 0.25-100; chlorpheniramine 0.05-20; cloperastine 0.10-40. Intra- and inter-day precisions (as relative standard deviation) were all < or =11.3% with accuracy (as relative error) of +/-5.0%. The method was successfully applied to a study of the pharmacokinetics of the five analytes after administration of a combination oral dose to healthy Chinese volunteers.

  10. Stable isotope labeling tandem mass spectrometry (SILT): integration with peptide identification and extension to data-dependent scans.

    PubMed

    Elbert, Donald L; Mawuenyega, Kwasi G; Scott, Evan A; Wildsmith, Kristin R; Bateman, Randall J

    2008-10-01

    Quantitation of relative or absolute amounts of proteins by mass spectrometry can be prone to large errors. The use of MS/MS ion intensities and stable isotope labeling, which we term stable isotope labeling tandem mass spectrometry (SILT), decreases the effects of contamination from unrelated compounds. We present a software package (SILTmass) that automates protein identification and quantification by the SILT method. SILTmass has the ability to analyze the kinetics of protein turnover, in addition to relative and absolute protein quantitation. Instead of extracting chromatograms to find elution peaks, SILTmass uses only scans in which a peptide is identified and that meet an ion intensity threshold. Using only scans with identified peptides, the accuracy and precision of SILT is shown to be superior to precursor ion intensities, particularly at high or low dilutions of the isotope labeled compounds or with low amounts of protein. Using example scans, we demonstrate likely reasons for the improvements in quantitation by SILT. The appropriate use of variable modifications in peptide identification is described for measurement of protein turnover kinetics. The combination of identification with SILT facilitates quantitation without peak detection and helps to ensure the appropriate use of variable modifications for kinetics experiments.

  11. Optimized ultra performance liquid chromatography tandem high resolution mass spectrometry method for the quantification of paraquat in plasma and urine.

    PubMed

    Lu, Haihua; Yu, Jing; Wu, Linlin; Xing, Jingjing; Wang, Jun; Huang, Peipei; Zhang, Jinsong; Xiao, Hang; Gao, Rong

    2016-08-01

    A simple, sensitive and specific ultra performance liquid chromatography coupled to electrospray tandem high resolution mass spectrometry (UPLC-ESI-HRMS/MS) method has been developed and validated for quantification of paraquat in plasma and urine. The sample preparation was carried out by one-step protein precipitation with acetonitrile. The paraquat was separated with a HILIC column in 10min. Detection was performed using Q Exactive Orbitrap mass spectrometer by Targeted-MS/MS scan mode. Methodological parameters, such as ammonium formate concentration, formic acid concentration, spray voltage, capillary temperature, heater temperature and normalized collision energy were optimized to achieve the highest sensitivity. The calibration curve was linear over the concentration range of LOQ-1000ng/mL. LOD was 0.1 and 0.3ng/mL, LOQ was 0.3 and 0.8ng/mL for urine and plasma, respectively. The intra- and inter-day precisions were <7.97% and 4.78% for plasma and urine. The accuracies were within the range 93.51-100.90%. The plasma and urine matrices had negligible relative matrix effect in this study. This method was successfully applied to determine paraquat concentration in plasma samples with hemoperfusion from 5 suspected paraquat poisoning patients. PMID:27270261

  12. Determination of antimigraine compounds rizatriptan, zolmitriptan, naratriptan and sumatriptan in human serum by liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Vishwanathan, K; Bartlett, M G; Stewart, J T

    2000-01-01

    Development of a rapid, sensitive and selective method for the determination of antimigraine drugs from human serum is essential for understanding the pharmacokinetics of these drugs when administered concurrently. Solid phase extraction (SPE) using Oasis HLB was used to extract the drugs (sumatriptan, naratriptan, zolmitriptan and rizatriptan) and the internal standard bufotenine from serum. A method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated to simultaneously quantitate these antimigraine drugs from human serum. The precursor and major product ions of the analytes were monitored on a triple quadrupole mass spectrometer with positive ion electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. The base peak in all the analytes is formed by alpha cleavage associated with protonation of the secondary amine. Mechanisms for the formation of the collision-induced dissociation products of these antimigraine compounds are proposed. Linear calibration curves were generated from 1-100 ng/mL with all coefficients of determination greater than 0.99. The inter- and intraday precision (%RSD) were less than 9.3% and accuracy (%error) was less than 9.8% for all components. The limits of detection (LOD) for the method were 250 pg/mL for sumatriptan and 100 pg/mL for the remaining analytes based on a signal-to-noise ratio of 3. PMID:10637423

  13. Liquid Chromatography with Tandem Mass Spectrometry: A Sensitive Method for the Determination of Dehydrodiisoeugenol in Rat Cerebral Nuclei.

    PubMed

    Zhang, You-Bo; Yang, Xin-Bao; Yang, Xiu-Wei; Xu, Wei; Li, Fei; Gonzezal, Frank J

    2016-01-01

    A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is developed for the quantification of dehydrodiisoeugenol (DDIE) in rat cerebral nuclei after single intravenous administration. DDIE and daidzein (internal standard) were separated on a Diamonsil™ ODS C18 column with methanol-water containing 0.1% formic acid (81:19, v/v) as a mobile phase. Detection of DDIE was performed on a positive electrospray ionization source using a triple quadrupole mass spectrometer. DDIE and daidzein were monitored at m/z 327.2→188.0 and m/z 255.0→199.2, respectively, in multiple reaction monitoring mode. This method enabled quantification of DDIE in various brain areas, including, cortex, hippocampus, striatum, hypothalamus, cerebellum and brainstem, with high specificity, precision, accuracy, and recovery. The data herein demonstrate that our new LC-MS/MS method is highly sensitive and suitable for monitoring cerebral nuclei distribution of DDIE. PMID:27005607

  14. Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry.

    PubMed

    Chamkasem, Narong; Harmon, Tiffany

    2016-07-01

    Glyphosate, glufosinate, and aminomethylphosphonic acid (AMPA) are amphoteric, low mass, high water soluble, and do not have chromophore. They are very difficult to be retained on a reversed phase HPLC and detected by UV or fluorescence detectors. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed to determine these analytes in soybean and corn using a reversed phase with weak anion-exchange and cation-exchange mixed-mode Acclaim™ Trinity™ Q1 column. The sample was shaken with water containing ethylenediaminetetraacetic acid disodium salt (Na2EDTA) and acetic acid for 10 min to precipitate protein and extract the analytes into the solution. The supernatant was passed thru an Oasis HLB SPE to retain suspended particulates and non-polar interferences. The sample was directly injected and analyzed in 6 min by LC-MS/MS with no sample concentration or derivatization steps. Three isotopically labeled internal standards corresponding to each analyte were used to counter matrix suppression effect. Linearity of the detector response with a minimum coefficient of determination (R (2)) of more than 0.995 was demonstrated in the range of 10 to 1000 ng/mL for each analyte. Accuracy (recovery %) and precision (relative standard deviation or RSD %) were evaluated at the fortification levels of 0.1, 0.5, and 2 μg/g in seven replicates in both soybean and corn samples. PMID:27150204

  15. Screening of newborn infants for cholestatic hepatobiliary disease with tandem mass spectrometry

    PubMed Central

    Mushtaq, Imran; Logan, Stuart; Morris, Michael; Johnson, Andrew W; Wade, Angie M; Kelly, Deirdre; Clayton, Peter T

    1999-01-01

    Objective To assess the feasibility of screening for cholestatic hepatobiliary disease and extrahepatic biliary atresia by using tandem mass spectrometry to measure conjugated bile acids in dried blood spots obtained from newborn infants at 7-10 days of age for the Guthrie test. Setting Three tertiary referral clinics and regional neonatal screening laboratories. Design Unused blood spots from the Guthrie test were retrieved for infants presenting with cholestatic hepatobiliary disease and from the two cards stored on either side of each card from an index child. Concentrations of conjugated bile acids measured by tandem mass spectrometry in the two groups were compared. Main outcome measures Concentrations of glycodihydroxycholanoates, glycotrihydroxycholanoates, taurodihydroxycholanoates, and taurotrihydroxycholanoates. Receiver operator curves were plotted to determine which parameter (or combination of parameters) would best predict the cases of cholestatic hepatobiliary disease and extrahepatic biliary atresia. The sensitivity and specificity at a selection of cut off values for each bile acid species and for total bile acid concentrations for the detection of the two conditions were calculated. Results 218 children with cholestatic hepatobiliary disease were eligible for inclusion in the study. Two children without a final diagnosis and five who presented at <14 days of age were excluded. Usable blood spots were obtained from 177 index children and 708 comparison children. Mean concentrations of all four bile acid species were significantly raised in children with cholestatic hepatobiliary disease and extrahepatic biliary atresia compared with the unaffected children (P<0.0001). Of 177 children with cholestatic hepatobiliary disease, 104 (59%) had a total bile acid concentration >33 μmol/l (97.5th centile value for comparison group). Of the 61 with extrahepatic biliary atresia, 47 (77%) had total bile acid concentrations >33

  16. On-line monitoring of bioreactions of Bacillus polymyxa and Klebsiella oxytoca by membrane introduction tandem mass spectrometry with flow injection analysis sampling

    SciTech Connect

    Hayward, M.J.; Kotiaho, Tapio; Lister, A.K.; Cooks, R.G.; Austin, G.D.; Narayan, Ramani; Tsao, G.T. )

    1990-09-01

    Membrane introduction mass spectrometry with flow injection analysis sampling has been utilized for on-line monitoring of the major products and the volatile metabolites of fermentation of the Bacillus polymyxa and Klebsiella oxytoca organisms. A flow injection sampling system was used to rapidly deliver fermentation broth or an external standard to the mass spectrometer. Analyte introduction occurred via a direct insertion membrane probe in which the aqueous solutions flowed past a membrane located within the ion source of the mass spectrometer. For both organisms, concentrations of the liquid-phase products acetic acid, acetoin, 2,3-butanediol, and ethanol, were monitored as a function of time after permeation through the membrane and ionization by chemical ionization. Tandem mass spectrometry confirmed that these measurements were made without interference. Off-line gas chromatography was utilized to test the accuracy of these measurements, and excellent agreement was found. The use of tandem mass spectrometry has allowed the detection of additional compounds that were previously not known to be present in measurable amounts.

  17. Direct Measurement of Free Estradiol in Human Serum and Plasma by Equilibrium Dialysis-Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Ray, Julie A; Kushnir, Mark M; Rockwood, Alan L; Meikle, A Wayne

    2016-01-01

    We describe a direct method of measurement of free estradiol using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum aliquots and internal standards are extracted by liquid-liquid extraction using methyl-tert-butyl ether (MTBE) followed by derivatization with dansyl chloride. An API 5500 mass spectrometer operated in positive electrospray mode is used for detection.

  18. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    PubMed

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.

  19. Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry.

    PubMed

    Yoon, Hye-Ran

    2015-09-01

    The main purpose of newborn screening is to diagnose genetic, metabolic, and other inherited disorders, at their earliest to start treatment before the clinical manifestations become evident. Understanding and tracing the biochemical data obtained from tandem mass spectrometry is vital for early diagnosis of metabolic diseases associated with such disorders. Accordingly, it is important to focus on the entire diagnostic process, including differential and confirmatory diagnostic options, and the major factors that influence the results of biochemical analysis. Compared to regular biochemical testing, this is a complex process carried out by a medical physician specialist. It is comprised of an integrated program requiring multidisciplinary approach such as, pediatric specialist, expert scientist, clinical laboratory technician, and nutritionist. Tandem mass spectrometry is a powerful tool to improve screening of newborns for diverse metabolic diseases. It is likely to be used to analyze other treatable disorders or significantly improve existing newborn tests to allow broad scale and precise testing. This new era of various screening programs, new treatments, and the availability of detection technology will prove to be beneficial for the future generations. PMID:26512346

  20. Determination of biogenic amines in beer and wine by capillary electrophoresis-tandem mass spectrometry.

    PubMed

    Daniel, Daniela; Dos Santos, Vagner Bezerra; Vidal, Denis Tadeu Rajh; do Lago, Claudimir Lucio

    2015-10-16

    A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) method for the simultaneous assessment of nine biogenic amines (spermine, spermidine, putrescine, cadaverine, histamine, phenylethylamine, tryptamine, tyramine, and urocanic acid) in commercial samples of beer and wine is introduced. The samples were submitted to a simple clean-up step with poly(vinylpolypyrrolidone) followed by filtration. Electrophoretic separation in a polyvinyl alcohol (PVA)-coated capillary using 0.5 mol L(-1) acetic acid (pH 2.5) as background electrolyte and detection by electrospray-tandem mass spectrometry was employed. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.996-0.999, and the limits of detection and limits of quantification were in the range of 1-2 μg L(-1) and 3-8 μg L(-1), respectively. The recovery values for samples spiked at three concentration levels (0.2, 0.5, and 1.0 mg L(-1)) ranged from 87 to 113% with standard deviation not greater than 5.8%. The use of a PVA-coated silica capillary allows suppressing the electroosmotic flow and, consequently, increasing of the separation efficiency. The method was successfully used to determine biogenic amines in commercial samples of beer and wine.

  1. Determination of ochratoxin A in wine by immunoaffinity cleanup and liquid chromatography tandem mass spectrometry.

    PubMed

    Noba, Shigekuni; Omote, Masayuki; Kitagawa, Yasushi; Mochizuki, Naoki

    2008-05-01

    A simple and accurate method has been developed for determining ochratoxin A (OTA), using an immunoaffinity column for cleanup and liquid chromatography-tandem mass spectrometry for identification and quantification. Wine samples were diluted with a solution containing polyethylene glycol 8000 and sodium hydrogen carbonate, filtered through a glass microfiber filter, and cleaned up on an immunoaffinity column. OTA was then eluted with methanol-acetic acid (98:2) and analyzed by liquid chromatography-tandem mass spectrometry. The average recoveries of OTA from red and white wines were 95 and 96.7% (spiked OTA level was 0.05 ng/ml) and repeatabilities (relative standard deviation) were 3.8 and 2.4%, respectively. The detection limit was 0.0003 ng/ml based on the signal-to-noise ratio in wine of 3:1. Analysis of 74 samples of domestic and imported wines showed OTA levels ranging from < 0.0003 to 0.82 ng/ml, with an incidence of contamination of 92.1% for red wines, and < 0.0003 to 0.51 ng/ml, with an incidence of contamination of 77.8% for white wines. These detection rates were higher than those rates of past reports of OTA contamination in wine, due to the high sensitivity of this method. However, all samples analyzed in this study complied with European Union regulations. It is concluded that this method is a useful tool for the quality assurance of wine.

  2. Detection of glutaric acidemia type 1 in infants through tandem mass spectrometry.

    PubMed

    Babu, Ruby P; Bishnupriya, G; Thushara, P K; Alap, Christy; Cariappa, Rohit; Annapoorani; Viswanathan, Kasi

    2015-06-01

    Glutaric acidemia type 1 (GA1) is a rare inherited metabolic disorder which goes underdiagnosed due to its latency period and subtle presentation. A pilot clinical study was conducted to assess the usefulness, specificity and sensitivity of the tandem mass (MS/MS) spectrometer, specifically the Abbott (AB) Sciex 3200, in the screening for GA1 using dried blood spots. A total of 17,100 specimens, comprising pediatric patients and healthy newborns, were screened from June 2012 to June 2014. A selection criterion was applied to increase the range of samples tested. 14 of the total specimens tested presumptive positive for GA1, of whom all were symptomatic. The diagnosis was confirmed in 4 of the 14 cases and they were started on treatment. 4 cases expired before confirmation. The remaining cases were empirically started on treatment. Most of the patients responded favorably to the dietary management. One important observation was that the older symptomatic children diagnosed with GA1 had poorer outcomes in terms of recovery of delayed milestones and mental deterioration, further emphasizing the need for early diagnosis of organic acidemias along with the other biochemical defects. Tandem mass spectrometry was found to be more than 93.33% sensitive and more than 99.42% specific. The screening test proved to be very simple and economical. PMID:26937400

  3. Quantile map: simultaneous visualization of patterns in many distributions with application to tandem mass spectrometry.

    PubMed

    Tseng, George C

    2010-04-01

    High-throughput experiments have become more and more prevalent in biomedical research. The high-dimensional data have brought new challenges. Effective data reduction, summarization and visualization are important keys to initial exploration in the data mining. In this paper, we introduce a visualization tool, namely quantile map, to present information contained in a probabilistic distribution. We demonstrate its use as an effective visual analysis tool through the application of a tandem mass spectrometry data set. Information of quantiles of a distribution is presented in gradient colors by concentric doughnuts. The width of the doughnuts is proportional to the Fisher information of the distribution to present unbiased visualization effect. A parametric empirical Bayes (PEB) approach is shown to improve the simple maximum likelihood estimate (MLE) approach when estimating the Fisher information. In the motivating example from tandem mass spectrometry data, multiple probabilistic distributions are to be displayed in two-dimensional grids. A hierarchical clustering to reorder rows and columns and a gradient color selection from a Hue-Chroma-Luminance model, similar to that commonly applied in heatmaps of microarray analysis, are adopted to improve the visualization. Both simulations and the motivating example show superior performance of quantile map in summarization and visualization of such high-throughput data sets.

  4. Determination of ochratoxin A in wine by immunoaffinity cleanup and liquid chromatography tandem mass spectrometry.

    PubMed

    Noba, Shigekuni; Omote, Masayuki; Kitagawa, Yasushi; Mochizuki, Naoki

    2008-05-01

    A simple and accurate method has been developed for determining ochratoxin A (OTA), using an immunoaffinity column for cleanup and liquid chromatography-tandem mass spectrometry for identification and quantification. Wine samples were diluted with a solution containing polyethylene glycol 8000 and sodium hydrogen carbonate, filtered through a glass microfiber filter, and cleaned up on an immunoaffinity column. OTA was then eluted with methanol-acetic acid (98:2) and analyzed by liquid chromatography-tandem mass spectrometry. The average recoveries of OTA from red and white wines were 95 and 96.7% (spiked OTA level was 0.05 ng/ml) and repeatabilities (relative standard deviation) were 3.8 and 2.4%, respectively. The detection limit was 0.0003 ng/ml based on the signal-to-noise ratio in wine of 3:1. Analysis of 74 samples of domestic and imported wines showed OTA levels ranging from < 0.0003 to 0.82 ng/ml, with an incidence of contamination of 92.1% for red wines, and < 0.0003 to 0.51 ng/ml, with an incidence of contamination of 77.8% for white wines. These detection rates were higher than those rates of past reports of OTA contamination in wine, due to the high sensitivity of this method. However, all samples analyzed in this study complied with European Union regulations. It is concluded that this method is a useful tool for the quality assurance of wine. PMID:18522043

  5. Detection of various freshwater cyanobacterial toxins using ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Oehrle, Stuart A; Southwell, Ben; Westrick, Judy

    2010-05-01

    Several freshwater cyanobacteria species have the capability to produce toxic compounds, frequently referred to as cyanotoxins. The most prevalent of these cyanotoxins is microcystin LR. Recognizing the potential health risk, France, Italy, Poland, Australia, Canada, and Brazil have set either standards or guidelines for the amount of microcystin LR permissible in drinking water based on the World Health Organization guideline of one microg/L of microcystin LR. Recently, the United States Environmental Protection Agency has begun to evaluate the occurrence and health effects of cyanotoxins and their susceptibility to water treatment under the Safe Drinking Water Act through the Contaminant Candidate List (CCL). A recent update of the Contaminant Candidate List focuses research and data collection on the cyanotoxins microcystin LR, anatoxin-a, and cylindrospermopsin. Liquid Chromatography/Tandem-Mass Spectrometry (LC/MS/MS) is a powerful tool for the analysis of various analytes in a wide variety of matrices because of its sensitivity and selectivity. The use of smaller column media (sub 2 microm particles) was investigated to both improve the speed, sensitivity and resolution, and to quantify the CCL cyanotoxins, in a single analysis, using Ultra-Performance Liquid Chromatography (UPLC) combined with tandem mass spectrometry. Natural waters and spiked samples were analyzed to show proof-of-performance. The presented method was able to clearly resolve each of the cyanotoxins in less than eight minutes with specificity and high spike recoveries. PMID:19878689

  6. Determination of bromate in drinking water by ultraperformance liquid chromatography-tandem mass spectrometry.

    PubMed

    Alsohaimi, Ibrahim Hotan; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan; Abdalla, Mohammad Abulhassan; Busquets, Rosa; Alomary, Ahmad Khodran

    2012-10-01

    Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water. PMID:22815069

  7. Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma.

    PubMed

    Liu, Fei; Xu, Yu; Rui, Lei; Gao, Shu; Dong, Haijun; Guo, Qingxiang

    2006-01-01

    A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers.

  8. Screening newborns for metabolic disorders based on targeted metabolomics using tandem mass spectrometry

    PubMed Central

    2015-01-01

    The main purpose of newborn screening is to diagnose genetic, metabolic, and other inherited disorders, at their earliest to start treatment before the clinical manifestations become evident. Understanding and tracing the biochemical data obtained from tandem mass spectrometry is vital for early diagnosis of metabolic diseases associated with such disorders. Accordingly, it is important to focus on the entire diagnostic process, including differential and confirmatory diagnostic options, and the major factors that influence the results of biochemical analysis. Compared to regular biochemical testing, this is a complex process carried out by a medical physician specialist. It is comprised of an integrated program requiring multidisciplinary approach such as, pediatric specialist, expert scientist, clinical laboratory technician, and nutritionist. Tandem mass spectrometry is a powerful tool to improve screening of newborns for diverse metabolic diseases. It is likely to be used to analyze other treatable disorders or significantly improve existing newborn tests to allow broad scale and precise testing. This new era of various screening programs, new treatments, and the availability of detection technology will prove to be beneficial for the future generations. PMID:26512346

  9. Accurate and Efficient Resolution of Overlapping Isotopic Envelopes in Protein Tandem Mass Spectra

    PubMed Central

    Xiao, Kaijie; Yu, Fan; Fang, Houqin; Xue, Bingbing; Liu, Yan; Tian, Zhixin

    2015-01-01

    It has long been an analytical challenge to accurately and efficiently resolve extremely dense overlapping isotopic envelopes (OIEs) in protein tandem mass spectra to confidently identify proteins. Here, we report a computationally efficient method, called OIE_CARE, to resolve OIEs by calculating the relative deviation between the ideal and observed experimental abundance. In the OIE_CARE method, the ideal experimental abundance of a particular overlapping isotopic peak (OIP) is first calculated for all the OIEs sharing this OIP. The relative deviation (RD) of the overall observed experimental abundance of this OIP relative to the summed ideal value is then calculated. The final individual abundance of the OIP for each OIE is the individual ideal experimental abundance multiplied by 1 + RD. Initial studies were performed using higher-energy collisional dissociation tandem mass spectra on myoglobin (with direct infusion) and the intact E. coli proteome (with liquid chromatographic separation). Comprehensive data at the protein and proteome levels, high confidence and good reproducibility were achieved. The resolving method reported here can, in principle, be extended to resolve any envelope-type overlapping data for which the corresponding theoretical reference values are available. PMID:26439836

  10. Determination of biogenic amines in beer and wine by capillary electrophoresis-tandem mass spectrometry.

    PubMed

    Daniel, Daniela; Dos Santos, Vagner Bezerra; Vidal, Denis Tadeu Rajh; do Lago, Claudimir Lucio

    2015-10-16

    A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) method for the simultaneous assessment of nine biogenic amines (spermine, spermidine, putrescine, cadaverine, histamine, phenylethylamine, tryptamine, tyramine, and urocanic acid) in commercial samples of beer and wine is introduced. The samples were submitted to a simple clean-up step with poly(vinylpolypyrrolidone) followed by filtration. Electrophoretic separation in a polyvinyl alcohol (PVA)-coated capillary using 0.5 mol L(-1) acetic acid (pH 2.5) as background electrolyte and detection by electrospray-tandem mass spectrometry was employed. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.996-0.999, and the limits of detection and limits of quantification were in the range of 1-2 μg L(-1) and 3-8 μg L(-1), respectively. The recovery values for samples spiked at three concentration levels (0.2, 0.5, and 1.0 mg L(-1)) ranged from 87 to 113% with standard deviation not greater than 5.8%. The use of a PVA-coated silica capillary allows suppressing the electroosmotic flow and, consequently, increasing of the separation efficiency. The method was successfully used to determine biogenic amines in commercial samples of beer and wine. PMID:26362807

  11. Denoising peptide tandem mass spectra for spectral libraries: a Bayesian approach.

    PubMed

    Shao, Wenguang; Lam, Henry

    2013-07-01

    With the rapid accumulation of data from shotgun proteomics experiments, it has become feasible to build comprehensive and high-quality spectral libraries of tandem mass spectra of peptides. A spectral library condenses experimental data into a retrievable format and can be used to aid peptide identification by spectral library searching. A key step in spectral library building is spectrum denoising, which is best accomplished by merging multiple replicates of the same peptide ion into a consensus spectrum. However, this approach cannot be applied to "singleton spectra," for which only one observed spectrum is available for the peptide ion. We developed a method, based on a Bayesian classifier, for denoising peptide tandem mass spectra. The classifier accounts for relationships between peaks, and can be trained on the fly from consensus spectra and immediately applied to denoise singleton spectra, without hard-coded knowledge about peptide fragmentation. A linear regression model was also trained to predict the number of useful "signal" peaks in a spectrum, thereby obviating the need for arbitrary thresholds for peak filtering. This Bayesian approach accumulates weak evidence systematically to boost the discrimination power between signal and noise peaks, and produces readily interpretable conditional probabilities that offer valuable insights into peptide fragmentation behaviors. By cross validation, spectra denoised by this method were shown to retain more signal peaks, and have higher spectral similarities to replicates, than those filtered by intensity only.

  12. High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

    NASA Technical Reports Server (NTRS)

    Craft, D. William

    1992-01-01

    A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

  13. High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

    NASA Astrophysics Data System (ADS)

    Craft, D. William

    1992-02-01

    A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

  14. Identification of Asp isomerization in proteins by ¹⁸O labeling and tandem mass spectrometry.

    PubMed

    Zhang, Jennifer; Katta, Viswanatham

    2012-01-01

    Isomerization of aspartic acid (Asp) to isoaspartic acid (isoAsp) via succinimide intermediate is a common route of degradation for proteins that can affect their structural integrity. As Asp/isoAsp is isobaric in mass, it is difficult to identify the site of modification by LC-MS/MS peptide mapping. Here, we describe an approach to label the Asp residue involved in isomerization at the protein level by hydrolyzing the succinimide intermediate in H₂¹⁸O. Tryptic digestion of this labeled protein will result in peptides containing the site of isomerization being 2 Da heavier than the ¹⁶O-containing counterparts, due to ¹⁸O incorporation during the hydrolysis process. Comparison of tandem mass spectra of isomerized peptides with and without ¹⁸O incorporation allows easy identification of the Asp residue involved. This method proved to be especially useful in identifying the sites when isomerization occurs in Asp-Asp motifs.

  15. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    PubMed

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010.

  16. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

    PubMed

    Remane, Daniela; Wissenbach, Dirk K; Peters, Frank T

    2016-09-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010. PMID:27452180

  17. Quantitative determination of tilmicosin in canine serum by high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Herrera, Michael; Ding, Haiqing; McClanahan, Robert; Owens, Jane G; Hunter, Robert P

    2007-09-15

    A highly sensitive and quantitative LC/MS/MS assay for the determination of tilmicosin in serum has been developed and validated. For sample preparation, 0.2 mL of canine serum was extracted with 3 mL of methyl tert-butyl ether. The organic layer was transferred to a new vessel and dried under nitrogen. The sample was then reconstituted for analysis by high performance liquid chromatography-tandem mass spectrometry. A Phenomenex Luna C8(2) analytical column was used for the chromatographic separation. The eluent was subsequently introduced to the mass spectrometer by electrospray ionization. A single range was validated for 50-5000 ng/mL for support of toxicokinetic studies. The inter-day relative error (inaccuracy) for the LLOQ samples ranged from -5.5% to 0.3%. The inter-day relative standard deviations (imprecision) at the respective LLOQ levels were < or =10.1%.

  18. Characterisation of phosphorylated nucleotides by collisional and electron‐based tandem mass spectrometry

    PubMed Central

    Ball, Andrew T.; Prakash, Aruna S.; Bristow, Anthony W.T.; Sims, Martin

    2016-01-01

    Rationale Tandem mass spectrometry of phosphorylated ions can often yield a limited number of product ions owing to the labile nature of phosphate groups. Developing techniques to improve dissociation for this type of ion has implications for the structural characterisation of many different phosphorylated ions, such as those from nucleotides, pharmaceutical compounds, peptides and polymers. Methods Solutions of adenosine monophosphate, diphosphate and triphosphate (AMP, ADP and ATP) were studied in a hybrid linear ion trap–Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. Precursor ions with an overall single positive charge, including protonated nucleotides or nucleotide cations containing one, two or three sodium atoms, were isolated for tandem mass spectrometry. Collision‐induced dissociation (CID) was performed in the linear ion trap, with electron‐induced dissociation (EID) being conducted in the FTICR cell. Results EID resulted in many product ions not seen in CID. EID product ion spectra were seen to vary for AMP, ADP and ATP when the nucleotide cation contained zero, one, two or three sodiums. Precursor cations that contain two or three sodiums mainly formed product ions derived from the phosphate group. Conversely, when a precursor ion containing no sodium underwent EID, product ions mainly relating to the non‐phosphate end of the ion were observed. The number of phosphate groups was not seen to greatly affect either CID or EID product ion spectra. Conclusions The presence of sodium in a precursor ion directs electron‐induced bond dissociation, thus enabling targeted, and therefore tuneable, fragmentation of groups within that precursor ion. For all precursor ions, the most useful product ion spectra were obtained by EID for a precursor ion containing one sodium, with bond dissociation occurring across the entire nucleotide cation. The findings of this study can be used to improve the structural elucidation of many

  19. Automated Glycan Sequencing from Tandem Mass Spectra of N-Linked Glycopeptides.

    PubMed

    Yu, Chuan-Yih; Mayampurath, Anoop; Zhu, Rui; Zacharias, Lauren; Song, Ehwang; Wang, Lei; Mechref, Yehia; Tang, Haixu

    2016-06-01

    Mass spectrometry has become a routine experimental tool for proteomic biomarker analysis of human blood samples, partly due to the large availability of informatics tools. As one of the most common protein post-translational modifications (PTMs) in mammals, protein glycosylation has been observed to alter in multiple human diseases and thus may potentially be candidate markers of disease progression. While mass spectrometry instrumentation has seen advancements in capabilities, discovering glycosylation-related markers using existing software is currently not straightforward. Complete characterization of protein glycosylation requires the identification of intact glycopeptides in samples, including identification of the modification site as well as the structure of the attached glycans. In this paper, we present GlycoSeq, an open-source software tool that implements a heuristic iterated glycan sequencing algorithm coupled with prior knowledge for automated elucidation of the glycan structure within a glycopeptide from its collision-induced dissociation tandem mass spectrum. GlycoSeq employs rules of glycosidic linkage as defined by glycan synthetic pathways to eliminate improbable glycan structures and build reasonable glycan trees. We tested the tool on two sets of tandem mass spectra of N-linked glycopeptides cell lines acquired from breast cancer patients. After employing enzymatic specificity within the N-linked glycan synthetic pathway, the sequencing results of GlycoSeq were highly consistent with the manually curated glycan structures. Hence, GlycoSeq is ready to be used for the characterization of glycan structures in glycopeptides from MS/MS analysis. GlycoSeq is released as open source software at https://github.com/chpaul/GlycoSeq/ . PMID:27111718

  20. Determination of usnic acid in lichen toxic to elk by liquid chromatography with ultraviolet and tandem mass spectrometry detection.

    PubMed

    Roach, John A G; Musser, Steven M; Morehouse, Kim; Woo, Jason Y J

    2006-04-01

    Usnic acid is unambiguously confirmed by tandem mass spectrometry (MS/MS) in tumbleweed shield lichen, Xanthoparmelia chlorochroa. The lichen contains 2% usnic acid by liquid chromatography with UV quantification at 282 nm. The UV linear range for usnic acid quantification is from its 4 ng limit of detection to 2 microg injected. UV signal saturation is recognized by distortion of the usnic acid UV spectrum. Positive ion electrospray-tandem mass spectrometry offers no similar means to recognize quantification data recorded above the linear range of electrospray. Electrospray ionization capacity and matrix effects limit the reliability of tandem mass spectrometry quantification. The combination of UV quantification and MS confirmation provides a reliable analytical method for measuring usnic acid levels in plant material. PMID:16569032

  1. Determination of usnic acid in lichen toxic to elk by liquid chromatography with ultraviolet and tandem mass spectrometry detection.

    PubMed

    Roach, John A G; Musser, Steven M; Morehouse, Kim; Woo, Jason Y J

    2006-04-01

    Usnic acid is unambiguously confirmed by tandem mass spectrometry (MS/MS) in tumbleweed shield lichen, Xanthoparmelia chlorochroa. The lichen contains 2% usnic acid by liquid chromatography with UV quantification at 282 nm. The UV linear range for usnic acid quantification is from its 4 ng limit of detection to 2 microg injected. UV signal saturation is recognized by distortion of the usnic acid UV spectrum. Positive ion electrospray-tandem mass spectrometry offers no similar means to recognize quantification data recorded above the linear range of electrospray. Electrospray ionization capacity and matrix effects limit the reliability of tandem mass spectrometry quantification. The combination of UV quantification and MS confirmation provides a reliable analytical method for measuring usnic acid levels in plant material.

  2. Dereplication of Streptomyces sp. AMC 23 polyether ionophore antibiotics by accurate-mass electrospray tandem mass spectrometry.

    PubMed

    Crevelin, Eduardo J; Crotti, Antônio E M; Zucchi, Tiago D; Melo, Itamar S; Moraes, Luiz A B

    2014-11-01

    Actinomycetes, especially those belonging to the genus Streptomyces, are economically important from a biotechnological standpoint: they produce antibiotics, anticancer compounds and a variety of bioactive substances that are potentially applicable in the agrochemical and pharmaceutical industries. This paper combined accurate-mass electrospray tandem mass spectrometry in the full scan and product ion scan modes with compounds library data to identify the major compounds in the crude extract produced by Streptomyces sp. AMC 23; it also investigated how sodiated nonactin ([M + Na](+)) fragmented. Most product ions resulted from elimination of 184 mass units due to consecutive McLafferty-type rearrangements. The data allowed identification of four macrotetrolides homologous to nonactin (monactin, isodinactin, isotrinactin/trinactin and tetranactin) as well as three related linear dimer compounds (nonactyl nonactoate, nonactyl homononactoate and homononactyl homononactoate). The major product ions of the sodiated molecules of these compounds also originated from elimination of 184 and 198 mass units. UPLC-MS/MS in the neutral loss scan mode helped to identify these compounds on the basis of the elimination of 184 and 198 mass units. This method aided monitoring of the relative production of these compounds for 32 days and revealed that the biosynthetic process began with increased production of linear dimers as compared with macrotetrolides. These data could facilitate dereplication and identification of these compounds in other microbial crude extracts.

  3. Determining elemental composition of phytochemicals in camelina seed meal by high mass accuracy and spectral accuracy

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An optimized single run evaluation that would accurately determine the elemental composition of as many compounds present in an extract would greatly aid in the evaluation of plant tissues. For phytochemicals, we have used accurate mass analysis to quickly characterize the potential chemical formula...

  4. The analysis of diagnostic markers of genetic disorders in human blood and urine using tandem mass spectrometry with liquid secondary ion mass spectrometry

    NASA Astrophysics Data System (ADS)

    Millington, David S.; Kodo, Naoki; Terada, Naoto; Roe, Diane; Chace, Donald H.

    1991-12-01

    A method has been developed for the rapid diagnosis of metabolic diseases based on the analysis of characteristic metabolites in body fluids by fast atom bombardment or liquid secondary ion tandem mass spectrometry (FAB-MS--MS or LSIMS--MS). Acylcarnitine profiles were obtained from 100 [mu]l urine. 200 [mu]l plasma or 25 [mu]l whole blood spotted onto filter paper by simple solvent extraction, esterification and analysis using a precursor ion scan function on a triple quadrupole mass spectrometer. Specificity and sensitivity were improved by adding a small percentage of sodium octyl sulfate to the liquid matrix, which forms ion pairs with acylcarnitine esters. Acylglycines in urine were specifically detected as a group using a different precursor ion scan function. By forming methyl esters, metabolic profiles of both acylcarnitines and acylglycines were achieved in the same sample loading by application of alternating scan functions. Quantitative analysis of selected metabolites was achieved by use of stable isotope-labeled internal standards. Amino acid profiles were obtained from 100 [mu]l plasma and 25 [mu]l whole blood spots using butyl esters and a neutral loss scan function. The quantitative analysis of phenylalanine and tyrosine was achieved in these samples using stable isotope dilution. This capability will facilitate the diagnosis of phenylketonuria and other amino acidemias. These new methods have the requirements of speed, accuracy and capability for automation necessary for large-scale neonatal screening of inborn errors of matabolism.

  5. Quantification of Photocyanine in Human Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in a Pharmacokinetic Study

    PubMed Central

    Bi, Bing-Tian; Zou, Ben-Yan; Deng, Li-Ting; Zhan, Jing; Liao, Hai; Feng, Kun-Yao; Li, Su

    2014-01-01

    Photocyanine is a novel anticancer drug. Its pharmacokinetic study in cancer patients is therefore very important for choosing doses, and dosing intervals in clinical application. A rapid, selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and validated for the determination of photocyanine in patient serum. Sample preparation involved one-step protein precipitation by adding methanol and N,N-dimethyl formamide to 0.1 mL serum. The detection was performed on a triple quadrupole tandem mass spectrometer operating in multiple reaction-monitoring (MRM) mode. Each sample was chromatographed within 7 min. Linear calibration curves were obtained for photocyanine at a concentration range of 20–2000 ng/mL (r > 0.995), with the lower limit of quantification (LLOQ) being 20 ng/mL. The intrabatch accuracy ranged from 101.98% to 107.54%, and the interbatch accuracy varied from 100.52% to 105.62%. Stability tests showed that photocyanine was stable throughout the analytical procedure. This study is the first to utilize the HPLC-MS/MS method for the pharmacokinetic study of photocyanine in six cancer patients who had received a single dose of photocyanine (0.1 mg/kg) administered intravenously. PMID:25050190

  6. Clustering and Filtering Tandem Mass Spectra Acquired in Data-Independent Mode

    NASA Astrophysics Data System (ADS)

    Pak, Huisong; Nikitin, Frederic; Gluck, Florent; Lisacek, Frederique; Scherl, Alexander; Muller, Markus

    2013-12-01

    Data-independent mass spectrometry activates all ion species isolated within a given mass-to-charge window ( m/z) regardless of their abundance. This acquisition strategy overcomes the traditional data-dependent ion selection boosting data reproducibility and sensitivity. However, several tandem mass (MS/MS) spectra of the same precursor ion are acquired during chromatographic elution resulting in large data redundancy. Also, the significant number of chimeric spectra and the absence of accurate precursor ion masses hamper peptide identification. Here, we describe an algorithm to preprocess data-independent MS/MS spectra by filtering out noise peaks and clustering the spectra according to both the chromatographic elution profiles and the spectral similarity. In addition, we developed an approach to estimate the m/z value of precursor ions from clustered MS/MS spectra in order to improve database search performance. Data acquired using a small 3 m/z units precursor mass window and multiple injections to cover a m/z range of 400-1400 was processed with our algorithm. It showed an improvement in the number of both peptide and protein identifications by 8 % while reducing the number of submitted spectra by 18 % and the number of peaks by 55 %. We conclude that our clustering method is a valid approach for data analysis of these data-independent fragmentation spectra. The software including the source code is available for the scientific community.

  7. Molecular resolution and fragmentation of fulvic acid by electrospray ionization/multistage tandem mass spectrometry

    USGS Publications Warehouse

    Leenheer, J.A.; Rostad, C.E.; Gates, Paul M.; Furlong, E.T.; Ferrer, I.

    2001-01-01

    Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.

  8. Advanced Laser Architecture for Two-Step Laser Tandem Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Fahey, Molly E.; Li, Steven X.; Yu, Anthony W.; Getty, Stephanie A.

    2016-01-01

    Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. These missions require advanced instrument techniques to fully and unambiguously characterize the composition of surface and dust materials. Laser desorptionionization mass spectrometry (LDMS) is an emerging instrument technology for in situ mass analysis of non-volatile sample composition. A recent Goddard LDMS advancement is the two-step laser tandem mass spectrometer (L2MS) instrument to address the need for future flight instrumentation to deconvolve complex organic signatures. The L2MS prototype uses a resonance enhanced multi-photon laser ionization mechanism to selectively detect aromatic species from a more complex sample. By neglecting the aliphatic and inorganic mineral signatures in the two-step mass spectrum, the L2MS approach can provide both mass assignments and clues to structural information for an in situ investigation of non-volatile sample composition. In this paper we will describe our development effort on a new laser architecture that is based on the previously flown Lunar Orbiter Laser Altimeter (LOLA) laser transmitter for the L2MS instrument. The laser provides two discrete midinfrared wavelengths (2.8 m and 3.4 m) using monolithic optical parametric oscillators and ultraviolet (UV) wavelength (266 nm) on a single laser bench with a straightforward development path toward flight readiness.

  9. Determination of abacavir, tenofovir, darunavir, and raltegravir in human plasma and saliva using liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Yamada, Eiko; Takagi, Ritsuo; Sudo, Koji; Kato, Shingo

    2015-10-10

    A liquid chromatography-tandem mass spectrometry assay for the determination of abacavir (ABC), tenofovir (TFV), darunavir (DRV), and raltegravir (RAL) in human plasma and saliva was developed and validated to investigate the applicability of saliva as an appropriate specimen for therapeutic drug monitoring. As internal standards, TFV was chosen for ABC, ABC was chosen for TFV, RAL for DRV, and DRV for RAL. Sample preparation involved protein precipitation with acetonitrile, evaporation of solvent using a centrifugal evaporator, and reconstitution by dissolving the residue in mobile phase. Liquid chromatography was performed on a C18 reverse phase column (1.5 × 50 mm, 5 μm) isocratically at a flow rate of 0.2 mL/min using 5mM formic acid-3% (v/v) acetonitrile as the mobile phase for ABC and TFV and 5mM formic acid-35% (v/v) acetonitrile as the mobile phase for DRV and RAL. The run time was 6 min, and the retention time was approximately 2.0 min for TFV, 2.5 min for RAL, and 4-4.5 min for ABC and DRV. Analytes were detected using tandem mass spectrometry in positive electrospray ionization mode. The precursor/product ion transitions (m/z) were 287.3/191.2 for ABC, 288.5/176.2 for TFV, 548.3/392.3 for DRV, and 445.3/109.5 for RAL, and were monitored on a triple-quadrupole mass spectrometer operated in the multiple reaction monitoring mode. The linearity of the assay was assessed in the range 1-10,000 ng/mL for all four drugs. Within-run and between-run mean accuracy, precision, and the extraction recovery for all drugs were -14.5-18.1%, 1.2-13.1%, and 86.0-111.1%, respectively. The proposed assay is sufficiently sensitive and accurate to quantify these drugs in plasma and saliva, and is suitable for investigating the relationship between drug concentrations in plasma and saliva.

  10. GenoMass software: a tool based on electrospray ionization tandem mass spectrometry for characterization and sequencing of oligonucleotide adducts

    PubMed Central

    Sharma, Vaneet K; Glick, James; Liao, Qing; Shen, Chang; Vouros, Paul

    2012-01-01

    The analysis of DNA adducts is of importance in understanding DNA damage, and in the last few years mass spectrometry (MS) has emerged as the most comprehensive and versatile tool for routine characterization of modified oligonucleotides. The structural analysis of modified oligonucleotides, although routinely analyzed using mass spectrometry, is followed by a large amount of data, and a significant challenge is to locate the exact position of the adduct by computational spectral interpretation, which still is a bottleneck. In this report, we present an additional feature of the in-house developed GenoMass software, which determines the exact location of an adduct in modified oligonucleotides by connecting tandem mass spectrometry (MS/MS) to a combinatorial isomer library generated in silico for nucleic acids. The performance of this MS/MS approach using GenoMass software was evaluated by MS/MS data interpretation for an unadducted and its corresponding N-acetylaminofluorene (AAF) adducted 17-mer (5′OH-CCT ACC CCT TCC TTG TA-3′OH) oligonucleotide. Further computational screening of this AAF adducted 17-mer oligonucleotide (5′OH-CCT ACC CCT TCC TTG TA-3′OH) from a complex oligonucleotide mixture was performed using GenoMass. Finally, GenoMass was also used to identify the positional isomers of the AAF adducted 15-mer oligonucleotide (5′OH-ATGAACCGGAGGCCC-3′OH). GenoMass is a simple, fast, data interpretation software that uses an in silico constructed library to relate the MS/MS sequencing approach to identify the exact location of adduct on oligonucleotides. PMID:22689626

  11. Large scale pesticide multiresidue methods in food combining liquid chromatography--time-of-flight mass spectrometry and tandem mass spectrometry.

    PubMed

    García-Reyes, Juan F; Hernando, M Dolores; Ferrer, Carmen; Molina-Díaz, Antonio; Fernández-Alba, Amadeo R

    2007-10-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) and liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) are powerful and complementary techniques that can independently cover the majority of the challenges related with pesticide residue food control. The sequential combination of both systems benefits from their complementary advantages and assists to increase the performance and to simplify routine large scale pesticide multiresidue methods. The proposed approach consists of three stages: (1) automated pesticide screening by LC-TOFMS; (2) identification by LC-TOFMS accurate mass measurements; and (3) confirmation and quantitation by LC-MS/MS. We have developed a fast comprehensive (identification/confirmation + quantitation) automated screening method for 100 target pesticides in crops. In the first stage, a set of data including m/z accurate mass windows (within 20 mDa width) and retention time is obtained (using a standard solution containing all the targeted pesticides) in order to build the automated screening procedure, which is created automatically by assigning retention time and the m/z mass window for each target pesticide. Samples are then analyzed, and the method enables the screening and preliminary identification of the species first by retention time and m/z mass window, followed by subsequent identification (only if positive results) by LC-TOFMS accurate mass measurements. After that, final confirmation of the positive findings using two MRM transitions and accurate quantitation is performed by LC-MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) mass spectrometer. In addition, the use of this QqLIT instrument also offers additional advantageous scanning modes (enhanced product ion and MS3 modes) for confirmatory purposes in compounds with poor fragmentation. Examples of applications to real samples show the potential of the proposed approach, including the detection of nonselected "a priori" compounds as a

  12. Molecular Isotopic Distribution Analysis (MIDAs) with Adjustable Mass Accuracy

    NASA Astrophysics Data System (ADS)

    Alves, Gelio; Ogurtsov, Aleksey Y.; Yu, Yi-Kuo

    2014-01-01

    In this paper, we present Molecular Isotopic Distribution Analysis (MIDAs), a new software tool designed to compute molecular isotopic distributions with adjustable accuracies. MIDAs offers two algorithms, one polynomial-based and one Fourier-transform-based, both of which compute molecular isotopic distributions accurately and efficiently. The polynomial-based algorithm contains few novel aspects, whereas the Fourier-transform-based algorithm consists mainly of improvements to other existing Fourier-transform-based algorithms. We have benchmarked the performance of the two algorithms implemented in MIDAs with that of eight software packages (BRAIN, Emass, Mercury, Mercury5, NeutronCluster, Qmass, JFC, IC) using a consensus set of benchmark molecules. Under the proposed evaluation criteria, MIDAs's algorithms, JFC, and Emass compute with comparable accuracy the coarse-grained (low-resolution) isotopic distributions and are more accurate than the other software packages. For fine-grained isotopic distributions, we compared IC, MIDAs's polynomial algorithm, and MIDAs's Fourier transform algorithm. Among the three, IC and MIDAs's polynomial algorithm compute isotopic distributions that better resemble their corresponding exact fine-grained (high-resolution) isotopic distributions. MIDAs can be accessed freely through a user-friendly web-interface at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/midas/index.html.

  13. Mining Large Scale Tandem Mass Spectrometry Data for Protein Modifications Using Spectral Libraries.

    PubMed

    Horlacher, Oliver; Lisacek, Frederique; Müller, Markus

    2016-03-01

    Experimental improvements in post-translational modification (PTM) detection by tandem mass spectrometry (MS/MS) has allowed the identification of vast numbers of PTMs. Open modification searches (OMSs) of MS/MS data, which do not require prior knowledge of the modifications present in the sample, further increased the diversity of detected PTMs. Despite much effort, there is still a lack of functional annotation of PTMs. One possibility to narrow the annotation gap is to mine MS/MS data deposited in public repositories and to correlate the PTM presence with biological meta-information attached to the data. Since the data volume can be quite substantial and contain tens of millions of MS/MS spectra, the data mining tools must be able to cope with big data. Here, we present two tools, Liberator and MzMod, which are built using the MzJava class library and the Apache Spark large scale computing framework. Liberator builds large MS/MS spectrum libraries, and MzMod searches them in an OMS mode. We applied these tools to a recently published set of 25 million spectra from 30 human tissues and present tissue specific PTMs. We also compared the results to the ones obtained with the OMS tool MODa and the search engine X!Tandem.

  14. Mining Large Scale Tandem Mass Spectrometry Data for Protein Modifications Using Spectral Libraries.

    PubMed

    Horlacher, Oliver; Lisacek, Frederique; Müller, Markus

    2016-03-01

    Experimental improvements in post-translational modification (PTM) detection by tandem mass spectrometry (MS/MS) has allowed the identification of vast numbers of PTMs. Open modification searches (OMSs) of MS/MS data, which do not require prior knowledge of the modifications present in the sample, further increased the diversity of detected PTMs. Despite much effort, there is still a lack of functional annotation of PTMs. One possibility to narrow the annotation gap is to mine MS/MS data deposited in public repositories and to correlate the PTM presence with biological meta-information attached to the data. Since the data volume can be quite substantial and contain tens of millions of MS/MS spectra, the data mining tools must be able to cope with big data. Here, we present two tools, Liberator and MzMod, which are built using the MzJava class library and the Apache Spark large scale computing framework. Liberator builds large MS/MS spectrum libraries, and MzMod searches them in an OMS mode. We applied these tools to a recently published set of 25 million spectra from 30 human tissues and present tissue specific PTMs. We also compared the results to the ones obtained with the OMS tool MODa and the search engine X!Tandem. PMID:26653734

  15. Synthesis, Structure, and Tandem Mass Spectrometric Characterization of the Diastereomers of Quinic Acid.

    PubMed

    Deshpande, Sagar; Matei, Marius Febi; Jaiswal, Rakesh; Bassil, Bassem S; Kortz, Ulrich; Kuhnert, Nikolai

    2016-09-28

    (-)-Quinic acid possess eight possible stereoisomers, which occur both naturally and as products of thermal food processing. In this contribution, we have selectively synthesized four isomers, namely, epi-quinic acid, muco-quinic acid, cis-quinic acid, and scyllo-quinic acid, to develop a tandem LC-MS method identifying all stereoisomeric quinic acids. Four derivatives have been unambiguously characterized by single-crystal X-ray crystallography. The missing diastereomers of quinic acid were obtained by nonselective isomerization of (-)-quinic acid using acetic acid/concentrated H2SO4 allowing chromatographic separation and assignment of all diastereomers of quinic acid. We report for the first time that a full set of stereoisomers are reliably distinguishable on the basis of their tandem mass spectrometric fragment spectra as well as their elution order. A rationale for characteristic fragmentation mechanisms is proposed. In this study, we also observed that muco-quinic acid, scyllo-quinic acid, and epi-quinic acid are present in hydrolyzed Guatemalan roasted coffee sample as possible products of roasting. PMID:27513177

  16. [Measurement of free urinary cortisol and cortisone using liquid chromatography associated with tandem mass spectrometry method].

    PubMed

    Vieira, José Gilberto H; Nakamura, Odete H; Carvalho, Valdemir M

    2005-04-01

    Free urinary cortisol (UFF) measurement is one of the most useful screening tests for Cushing's syndrome. Immunoassays employed today by most clinical laboratories present limitations, specially concerning specificity. These limitations restrain a widespread application of the method, as well as the comparison of results obtained by the use of different methods. We present the development and characterization of a UFF and cortisone method based on liquid chromatography and tandem mass spectrometry (LC-MS/MS). A 200 microL aliquot from a 24 h urine sample is mixed with a solution containing a known quantity of deuterated cortisol and on-line extracted in solid phase (C18). The eluate is transferred to a second C18 column (Phenomenex Luna, 3 micro, 50 x 2 mm) and the isocratic mode elution profile is directly applied to a tandem mass spectrometer model Quattro Micro operating in positive mode atmospheric pressure chemical ionization (APCI). All process is automated and the quantification is performed by isotopic dilution, based on the analyte and the deuterated internal standard peak area ratios. The specificity study showed that all the steroids tested presented cross reactivity of <1% for cortisol and cortisone. Functional sensitivity is <1 microg/L for both steroids, and the interassay CV <8%. Recovery and linearity studies were satisfactory and comparison of results obtained using a RIA for UFF and the present method in 98 routine samples showed a correlation of r= 0.838, with the results obtained with LC-MS/MS significantly lower (medians of 22.0 vs. 49.4 microg/24 h for RIA) (P<0.0001). Reference values for cortisol were defined as values between 11 and 43 microg/24 h, compatible to those recently described for similar methods. The concomitant measurement of UF cortisone allows the study of the activity of the enzyme 11beta-HSD2 and the diagnosis of the apparent mineralocorticoid excess syndrome. The method represents the first steroid assay of a new generation

  17. Applying Tandem Mass Spectral Libraries for Solving the Critical Assessment of Small Molecule Identification (CASMI) LC/MS Challenge 2012.

    PubMed

    Oberacher, Herbert

    2013-01-01

    The "Critical Assessment of Small Molecule Identification" (CASMI) contest was aimed in testing strategies for small molecule identification that are currently available in the experimental and computational mass spectrometry community. We have applied tandem mass spectral library search to solve Category 2 of the CASMI Challenge 2012 (best identification for high resolution LC/MS data). More than 230,000 tandem mass spectra part of four well established libraries (MassBank, the collection of tandem mass spectra of the "NIST/NIH/EPA Mass Spectral Library 2012", METLIN, and the 'Wiley Registry of Tandem Mass Spectral Data, MSforID') were searched. The sample spectra acquired in positive ion mode were processed. Seven out of 12 challenges did not produce putative positive matches, simply because reference spectra were not available for the compounds searched. This suggests that to some extent the limited coverage of chemical space with high-quality reference spectra is still a problem encountered in tandem mass spectral library search. Solutions were submitted for five challenges. Three compounds were correctly identified (kanamycin A, benzyldiphenylphosphine oxide, and 1-isopropyl-5-methyl-1H-indole-2,3-dione). In the absence of any reference spectrum, a false positive identification was obtained for 1-aminoanthraquinone by matching the corresponding sample spectrum to the structurally related compounds N-phenylphthalimide and 2-aminoanthraquinone. Another false positive result was submitted for 1H-benz[g]indole; for the 1H-benz[g]indole-specific sample spectra provided, carbazole was listed as the best matching compound. In this case, the quality of the available 1H-benz[g]indole-specific reference spectra was found to hamper unequivocal identification.

  18. Analysis of rocuronium in human plasma by liquid chromatography-tandem mass spectrometry with application in clinical pharmacokinetics.

    PubMed

    de Moraes, Natália Valadares; Lauretti, Gabriela Rocha; Filgueira, Gabriela Campos de Oliveira; Lopes, Bruno Carvalho Portes; Lanchote, Vera Lucia

    2014-03-01

    Rocuronium (ROC) is a neuromuscular blocking agent used in surgical procedures which is eliminated primarily by biliary excretion. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of ROC in human plasma. Separation of ROC and IS (verapamil) was performed using an endcapped C-18 column and a mixture of water:acetonitrile:trifluoracetic acid (50:50:0.1, v/v) as mobile phase. Aliquots of 100 μL of human plasma were extracted at pH 3, using dichloromethane. The lower limit of quantification of 5 ng/mL shows the high sensitivity of this method. Intra- and inter-assay precision (as relative standard deviation) was all ≤14.2% and accuracy (as relative standard error) did not exceed 10.1%. The validated method was successfully applied to quantify ROC concentrations in patients under surgical procedures up to 6h after the administration of the 0.4-0.9 mg/kg ROC. The pharmacokinetic parameter estimations of ROC showed AUC/dose of 563 μg min/mL, total clearance of 2.5 mL/min/kg, volume of distribution at steady state of 190 mL/kg and mean residence time of 83 min. PMID:24370612

  19. Analysis of thyreostatic drugs in thyroid samples by liquid chromatography tandem mass spectrometry: comparison of two sample treatment strategies.

    PubMed

    Abuín, S; Companyó, R; Centrich, F; Rúbies, A; Prat, M D

    2008-10-17

    A method based on ultra-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry (UPLC-MS/MS) for the determination of six thyreostatic drugs in thyroid tissue has been optimised and validated in accordance with Decision 2002/657/EC. Sample extraction was evaluated in methanol and in ethyl acetate, the latter which gave better results. Two clean-up strategies were compared: one based on silica cartridges (SPE), and the other, on gel permeation chromatography (GPC). Recoveries ranged from 40% to 79% for the SPE approach and from 80% to 109% for GPC. Quantification was performed with blank tissue samples spiked with the analytes in the range 50-500microgkg(-1). 5,6-Dimethyl-2-thiouracil and 2-mercaptobenzimidazole-d(4) were used as internal standards. Decision limit (CCalpha) and detection capability (CCbeta) ranged from 1 to 15microgkg(-1) and from 6 to 25microgkg(-1), respectively. The accuracy of the method was calculated as percent error, which was less than 10%. The relative standard deviation in reproducibility conditions ranged between 2% and 14%.

  20. Analysis of thyreostatic drugs in thyroid samples by ultra-performance liquid chromatography tandem mass spectrometry detection.

    PubMed

    Abuín, S; Centrich, F; Rúbies, A; Companyó, R; Prat, M D

    2008-06-01

    A method based on ultra-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry for the determination of six thyreostatic drugs in thyroid tissue has been optimised and validated in accordance with the Decision 2002/657/EC. Samples are extracted with methanol and the extracts cleaned-up on silica cartridges. The recoveries range from 40% for 6-phenyl-2-thiouracil to 79% for 2-thiouracil. Quantification is carried out with blank tissue samples spiked with the analytes in the range 25-500 microg kg(-1). 5,6-Dimethyl-2-thiouracil is used as internal standard. CCalpha and CCbeta are in the ranges 4.3-16.1 microg kg(-1) and 8.7-20.7 microg kg(-1), respectively. Accuracy, expressed as percentage of error, is lower than 6% and relative standard deviation in reproducibility conditions falls between 5.6 and 10.3%. Nowadays, the proposed method is routinely implemented in the laboratory of the Agència de Salut Pública de Barcelona and allows processing of up to 20 samples per day.

  1. Multiclass analysis of mycotoxins in biscuits by high performance liquid chromatography-tandem mass spectrometry. Comparison of different extraction procedures.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; Foglia, Patrizia; Samperi, Roberto; Stampachiacchiere, Serena; Ventura, Salvatore; Laganà, Aldo

    2014-05-23

    A sensitive, simple and rapid method for the simultaneous determination of 19 mycotoxins in biscuits (a dry matrix containing cereals and egg) has been developed using high performance liquid chromatography coupled to tandem mass spectrometry with electrospray source working in both positive and negative mode. Due to the matrix complexity and the high amount of contaminants, a solid phase extraction method using graphitized carbon black was optimized for an effective clean-up step. Accuracy was carried out in the selected matrix using blank samples spiked at three analyte concentrations. Recoveries between 63 and 107% and relative standard deviations lower than 12% were obtained. For all considered mycotoxin classes, i.e. thricotecenes A and B, zearalenone and its metabolites, fumonisins, ochratoxin A, enniatins and their structurally related beauvericin, the method was validated in terms of linearity, recovery, matrix effect, precision, limit of detection and limit of quantification. Matrix-matched calibration was used for quantification purposes, in order to compensate for matrix effect. The coefficients of determination obtained were in the range of 0.9927-1. The limits of quantification, ranging from 0.04μgkg(-1) for enniatin B1 to 80.2μgkg(-1) for nivalenol, were always lower than maximum permitted levels for every regulated mycotoxin by the current European legislation.

  2. [Simultaneous determination of six components in hair dyes by ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    You, Feiming

    2015-01-01

    A sensitive method was developed for the simultaneous determination of six components which included 4, 4'-diaminodiphenylamine sulfate hydrate and 2,4-diaminophenol sulfate, etc. in hair dyes by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). After extracted by water through ultrasonic extraction, the samples were analyzed by UPLC-MS/MS. The separation was performed on a Waters BEH-C18 column (100 mmx 2.1 mm, 1.7 microm) with gradient elution of 10 mmol/L ammonium acetate and acetonitrile. The electrospray ionization (ESI) source in positive ion mode was used for the analysis of the six components in the multiple reaction monitoring (MRM) mode. The results showed good linear relationships with all the correlation coefficients (R2) more than 0.99. The limits of detection (LODs, S/N=3) for the six components were in the range of 0.26-4.6 mg/kg. The average recoveries of the six components in the spiked samples were in the range of 83.0%-92.2% with the relative standard deviations (RSDs, n=6) of 5.4%-11.2%. The precision, accuracy, mean recoveries and the matrix effects satisfied the requirements of cosmetic sample measurement. The proposed method has been applied to the determination of six dyes in actual samples. This method is simple, accurate and effective for the simultaneous determination of the six components in hair dyes. PMID:25958662

  3. [Determination of 88 pesticide residues in cranberry plant extract by gas chromatography-triple quadrupole tandem mass spectrometry].

    PubMed

    Huang, Jiangrui; Kong, Xianghong; Yao, Binghua; He, Qiang; Hao, Kaituo

    2011-10-01

    A method by using a modified QuEChERS (quick, easy, cheap, effective, rugged and safe) and gas chromatography-triple quadrupole tandem mass spectrometry (GC-MS/MS) was established to analyze 88 pesticide residues in cranberry plant extract. The sample was extracted with acetone-hexane (1: 1, v/v) containing 1% acetic acid, then cleaned-up by ethylenediamine-N-propyl silyl (PSA) and graphite carbon (GCB). The extract was determined by GC-MS/MS in multi-reaction monitoring (MRM) mode, and external standard method was applied to quantified the pesticides. All the 88 pesticides showed good linearity in the range of 0. 001 - 0. 2 mg/L, and the limits of quantification (LOQs, S/N > or = 10) were all less than 31. 5 microg/kg. The average recoveries of all the pesticides were in the range of 71. 4% to 116. 6% at three spiked levels of 5, 25 and 50 microg/kg in cranberry plant extract, with the relative standard deviations (RSDs) of 2. 4% - 16. 9%. The results demonstrated that this method is simple, rapid and suitable for the determination of 88 pesticide residues in cranberry plant extract. The analytical sensitivity and accuracy can meet the requirements of multiple pesticide residue analysis.

  4. Study on pharmacokinetics of 3,4-divanillyltetrahydrofuran in rats by ultra-fast liquid chromatography/tandem mass spectrometry.

    PubMed

    Shan, Chen-xiao; Cui, Xiao-bing; Yu, Sheng; Chai, Chuan; Wen, Hong-mei; Wang, Xin-zhi; Sun, Xue

    2016-01-01

    3,4-Divanillyltetrahydrofuran is the main active ingredient of nettle root which can increase steroid hormones in the bloodstream for many of bodybuilders. To better understand its pharmacological activities, we need to determine its pharmacokinetic profiles. In this study, a rapid and sensitive ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed for the determination of 3,4-divanillyltetrahydrofuran in the plasma of rats. Chromatographic separation was performed on a C18 column at 40°C, with a gradient elution consisting of methanol and water containing 0.3% (v/v) formic acid at a flow rate of 0.8mL/min. The detection was performed using an electrospray triple-quadrupole MS/MS via positive ion multiple reaction monitoring mode. The lower limits-of-quantification determined were 0.5ng/mL. The intra- and inter-day precision (RSD%) was found to be within 15% and the accuracy (RE%) ranged from -4.0% to 7.0%. This simple yet sensitive method was fully validated and could be successfully applied to the study on pharmacokinetics of 3, 4-divanillyltetrahydrofuran. PMID:26680326

  5. Determining mycotoxins in baby foods and animal feeds using stable isotope dilution and liquid chromatography tandem mass spectrometry.

    PubMed

    Zhang, Kai; Wong, Jon W; Krynitsky, Alexander J; Trucksess, Mary W

    2014-09-10

    We developed a stable isotope dilution assay with liquid chromatography tandem mass spectrometry (LC-MS/MS) to determine multiple mycotoxins in baby foods and animal feeds. Samples were fortified with [(13)C]-uniformly labeled mycotoxins as internal standards ([(13)C]-IS) and prepared by solvent extraction (50% acetonitrile in water) and filtration, followed by LC-MS/MS analysis. Mycotoxins in each sample were quantitated with the corresponding [(13)C]-IS. In general, recoveries of aflatoxins (2-100 ng/g), deoxynivalenol, fumonisins (50-2000 ng/g), ochratoxin A (20-1000 ng/kg), T-2 toxin, and zearalenone (40-2000 ng/g) in tested matrices (grain/rice/oatmeal-based formula, animal feed, dry cat/dog food) ranged from 70 to 120% with relative standard deviations (RSDs) <20%. The method provides sufficient selectivity, sensitivity, accuracy, and reproducibility to screen for aflatoxins at ng/g concentrations and deoxynivalenol and fumonisins at low μg/g concentrations in baby foods and animal feeds, without using conventional standard addition or matrix-matched calibration standards to correct for matrix effects. PMID:25153173

  6. Determining mycotoxins in baby foods and animal feeds using stable isotope dilution and liquid chromatography tandem mass spectrometry.

    PubMed

    Zhang, Kai; Wong, Jon W; Krynitsky, Alexander J; Trucksess, Mary W

    2014-09-10

    We developed a stable isotope dilution assay with liquid chromatography tandem mass spectrometry (LC-MS/MS) to determine multiple mycotoxins in baby foods and animal feeds. Samples were fortified with [(13)C]-uniformly labeled mycotoxins as internal standards ([(13)C]-IS) and prepared by solvent extraction (50% acetonitrile in water) and filtration, followed by LC-MS/MS analysis. Mycotoxins in each sample were quantitated with the corresponding [(13)C]-IS. In general, recoveries of aflatoxins (2-100 ng/g), deoxynivalenol, fumonisins (50-2000 ng/g), ochratoxin A (20-1000 ng/kg), T-2 toxin, and zearalenone (40-2000 ng/g) in tested matrices (grain/rice/oatmeal-based formula, animal feed, dry cat/dog food) ranged from 70 to 120% with relative standard deviations (RSDs) <20%. The method provides sufficient selectivity, sensitivity, accuracy, and reproducibility to screen for aflatoxins at ng/g concentrations and deoxynivalenol and fumonisins at low μg/g concentrations in baby foods and animal feeds, without using conventional standard addition or matrix-matched calibration standards to correct for matrix effects.

  7. Rapid determination of apixaban concentration in human plasma by liquid chromatography/tandem mass spectrometry: application to pharmacokinetic study.

    PubMed

    Delavenne, Xavier; Mismetti, Patrick; Basset, Thierry

    2013-05-01

    We described the development and full validation of a rapid, high throughput sensible and accurate LC method using tandem mass spectrometry detection for determining apixaban concentration with [(¹³C, ²H₇]-apixaban as internal standard in human plasma. Plasma pretreatment involved a one-step protein precipitation with methanol. The separation was performed by reverse-phase chromatography on a Luna MercuryMS C18 column (20 mm × 4 mm × 3 μm) column. The multiple reaction monitoring transitions used for quantification were m/z 460.20→443.27 and 460.20→198.99 for apixaban, 468.22→451.30 for [(¹³C, ²H₇]-apixaban in the electrospray positive ionization mode. The method was linear over the concentration range of 5-500 μg/L. The intra- and inter-day precision values were below 14% and accuracy was from 90.0 to 105.8% at all quality control levels. Sample analysis time was less than 10 min including sample preparation. The present method was successfully applied to a pharmacokinetic study following oral administration of apixaban. PMID:23499913

  8. Analysis of thyreostatic drugs in thyroid samples by liquid chromatography tandem mass spectrometry: comparison of two sample treatment strategies.

    PubMed

    Abuín, S; Companyó, R; Centrich, F; Rúbies, A; Prat, M D

    2008-10-17

    A method based on ultra-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry (UPLC-MS/MS) for the determination of six thyreostatic drugs in thyroid tissue has been optimised and validated in accordance with Decision 2002/657/EC. Sample extraction was evaluated in methanol and in ethyl acetate, the latter which gave better results. Two clean-up strategies were compared: one based on silica cartridges (SPE), and the other, on gel permeation chromatography (GPC). Recoveries ranged from 40% to 79% for the SPE approach and from 80% to 109% for GPC. Quantification was performed with blank tissue samples spiked with the analytes in the range 50-500microgkg(-1). 5,6-Dimethyl-2-thiouracil and 2-mercaptobenzimidazole-d(4) were used as internal standards. Decision limit (CCalpha) and detection capability (CCbeta) ranged from 1 to 15microgkg(-1) and from 6 to 25microgkg(-1), respectively. The accuracy of the method was calculated as percent error, which was less than 10%. The relative standard deviation in reproducibility conditions ranged between 2% and 14%. PMID:18768184

  9. Analysis of thyreostatic drugs in thyroid samples by ultra-performance liquid chromatography tandem mass spectrometry detection.

    PubMed

    Abuín, S; Centrich, F; Rúbies, A; Companyó, R; Prat, M D

    2008-06-01

    A method based on ultra-performance liquid chromatography-electrospray ionisation-tandem mass spectrometry for the determination of six thyreostatic drugs in thyroid tissue has been optimised and validated in accordance with the Decision 2002/657/EC. Samples are extracted with methanol and the extracts cleaned-up on silica cartridges. The recoveries range from 40% for 6-phenyl-2-thiouracil to 79% for 2-thiouracil. Quantification is carried out with blank tissue samples spiked with the analytes in the range 25-500 microg kg(-1). 5,6-Dimethyl-2-thiouracil is used as internal standard. CCalpha and CCbeta are in the ranges 4.3-16.1 microg kg(-1) and 8.7-20.7 microg kg(-1), respectively. Accuracy, expressed as percentage of error, is lower than 6% and relative standard deviation in reproducibility conditions falls between 5.6 and 10.3%. Nowadays, the proposed method is routinely implemented in the laboratory of the Agència de Salut Pública de Barcelona and allows processing of up to 20 samples per day. PMID:18486656

  10. Application of a sensitive liquid chromatographic/tandem mass spectrometric method to pharmacokinetic study of nalmefene in humans.

    PubMed

    Li, Ping; Chen, Xiaoyan; Dai, Xiaojian; Wen, Aidong; Zhang, Yifan; Zhong, Dafang

    2007-06-01

    A sensitive, specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed and validated for quantification of nalmefene in human plasma. An aliquot of 200 microL plasma sample was simply precipitated by 400 microL methanol. Separation of nalmefene and the internal standard hydromorphone from the interferences was achieved on a C(18) column followed by MS/MS detection. The analytes were monitored in the positive ionization mode with a TurboIonspray source. The method had a total chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 10-5000 pg/mL. The lower limit of quantification (LLOQ) was 10 pg/mL. The intra- and inter-day precision was less than 10.1% determined from QC samples at concentrations of 30, 300 and 4500 pg/mL, and the accuracy was within +/-3.4%. As the method was more sensitive (10 times higher) than those reported previously, we investigated the pharmacokinetics of nalmefene in healthy volunteers after a single intravenous injection of low dose (30 microg) of nalmefene hydrochloride for the first time.

  11. Determination of eleven coccidiostats in animal feed by liquid chromatography-tandem mass spectrometry at cross contamination levels.

    PubMed

    Cronly, Mark; Behan, P; Foley, B; Malone, E; Shearan, P; Regan, L

    2011-08-26

    A confirmatory multi-residue method has been developed to allow for the detection, confirmation and quantification of eleven coccidiostats in animal feed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method can be used to determine halofuginone, robenidine, nicarbazin, diclazuril, decoquinate, semduramicin, lasalocid, monensin, salinomycin, narasin, maduramicin at levels relating to unavoidable carry over as stated in Regulation 2009/8/EC. Feed samples are extracted with water and acetonitrile with the addition of anhydrous magnesium sulphate and sodium chloride. The extract then undergoes a freezing out step before being diluted and injected onto the LC-MS/MS system. The LC-MS/MS system is run in MRM mode with both positive and negative electrospray ionisation and can confirm all eleven analytes in a run time of 19 min. The sensitivity of the method allows quantification and confirmation for all coccidiostats at a 0.5% carry over level. The method was validated over three days in accordance with of European legislation; Commission Decision 2002/657/EC. Validation criteria of accuracy, precision, decision limit (CCα), and detection capability (CCβ) along with measurement uncertainty are calculated for all analytes. The method was then successfully used to analyse a number of feed samples that contained various coccidiostat substances.

  12. High throughput liquid chromatography-tandem mass spectrometry assay for mercapturic acids of acrolein and crotonaldehyde in cigarette smokers' urine.

    PubMed

    Carmella, Steven G; Chen, Menglan; Zarth, Adam; Hecht, Stephen S

    2013-09-15

    3-Hydroxypropylmercapturic acid (3-HPMA) and 3-hydroxy-1-methylpropylmercapturic acid (HMPMA) are urinary metabolites of the toxicants acrolein and crotonaldehyde, respectively. Virtually all human urine samples contain these metabolites, resulting from the action of glutathione-S-transferases on acrolein and crotonaldehyde, which are lipid peroxidation products, environmental and dietary contaminants, and constituents of cigarette smoke. We have developed a high throughput liquid chromatography-tandem mass spectrometry method for quantitative analysis of 3-HPMA and HMPMA in large numbers of small urine samples, as would be required in molecular epidemiology and clinical studies relating levels of these metabolites to cancer risk. Solid-phase extraction on mixed mode reverse phase-anion exchange 96-well plates provided sufficient purification for LC-MS/MS analysis, which was performed by auto-injection using a 96-well format, and resulted in clean, readily interpretable chromatograms, with detection limits of 4.5pmol/mL urine for 3-HPMA and 3.5pmol/mL urine for HMPMA. Accuracy was 92% for 3-HPMA and 97% for HMPMA while inter-day precision was 9.1% (coefficient of variation) for 3-HPMA and 11.0% for HMPMA. The method was applied to more than 2600 urine samples from smokers; mean levels of 3-HPMA and HMPMA were 4800±5358 (S.D.)pmol/mL and 3302±3341pmol/mL, respectively.

  13. Folate Profiling in Potato (Solanum tuberosum) Tubers by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Van Daele, Jeroen; Blancquaert, Dieter; Kiekens, Filip; Van Der Straeten, Dominique; Lambert, Willy E; Stove, Christophe P

    2014-03-31

    An ultrahigh-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the profiling of six folate species in potatoes. The calibration curves cover a wide, linear range (the lower and upper limits of quantitation range between 0.22-0.24 and 216.07-242.28 μg/100 g of fresh weight), allowing sensitive determination in small amounts of potato flesh. With a single exception, the acceptance criteria for intra- and interday precision and accuracy were met: for all quality controls, the percent relative standard deviation and the percent bias were lower than 15% (or 20% at the lower limit of quantitation). Application of the method on tubers at different stages of maturation demonstrated the large variability within a single variety: the folate content and polyglutamylation rate varied between 10.35 and 24.01 μg/100 g of fresh weight and between 4.96% and 60.49%, respectively. Additionally, the two-dimensional folate profiling of mature tubers demonstrated an increase in folate from center to peel, combined with a stable species distribution and polyglutamylation rate.

  14. Microdialysis combined with liquid chromatography-tandem mass spectrometry for the determination of nimodipine in the guinea pig hippocampus.

    PubMed

    Wang, Chen; Lu, Xiaojing; Li, Liqin; Zhang, Ruihua; shi, Tong; Li, Shu

    2016-04-01

    Nimodipine is a dihydropyridine calcium-channel blocker that has been recently shown to be effective on the function of central nervous system. It has been reported that treatment against deficits of learning and memory in animals and human by maintain the calcium homeostasis in hippocampus with nimodipine may be promising therapeutic strategies. A rapid and sensitive liquid chromatography-tandem mass spectrometric method was developed to determination the nimodipine in hippocampus using microdialysis technique. The separation was accomplished on an Agilent Zorbax SB-C18 column (100mm×2.1mm ID, 3.5μm) with the mobile phase composed of methanol-water (80:20, v/v) containing 0.2% formic acid at a flow rate of 0.2ml/min. Multiple reaction monitoring of the precursor-product ion transitions 419→343 for nimodipine and 361→315 nitrendipine (IS) was used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.2ng/ml for nimodipine, with good linearity in the range of 0.2-20ng/ml. All the validation data, such as accuracy, precision, intra- and inter-day repeatability and stability were within the required limits. The method was successfully applied to p harmacokinetic study of the nimodipine in the guinea pig hippocampus.

  15. Simultaneous determination of fluoroquinolones in environmental water by liquid chromatography-tandem mass spectrometry with direct injection: A green approach.

    PubMed

    Denadai, Marina; Cass, Quezia Bezerra

    2015-10-30

    This work describes an on-line multi-residue method for simultaneous quantification of ciprofloxacin, enrofloxacin, gemifloxacin, moxifloxacin, norfloxacin and ofloxacin in superficial and wastewater samples. For that, an octyl restricted-access media bovine serum albumin column (RAM-BSA C8) was used for sample clean-up, enrichment and analysis with quantitation carried out by tandem mass spectrometry. For water samples volumes of only 500μL the method provided good selectivity, extraction efficiency, accuracy, and precision with quantification limits in the order of 20-150ngL(-1). Out of the six fluoroquinolones only ciprofloxacin (195ngL(-1)) and norfloxacin (270ngL(-1)) were quantified in an influent sample of the wastewater treatment plant (WWTP) of São Carlos (SP, Brazil). None were found in the superficial water samples analyzed. The capability of injecting native sample in an automated mode provides high productivity and represents a greener approach in environmental sample analysis.

  16. Analysis of rocuronium in human plasma by liquid chromatography-tandem mass spectrometry with application in clinical pharmacokinetics.

    PubMed

    de Moraes, Natália Valadares; Lauretti, Gabriela Rocha; Filgueira, Gabriela Campos de Oliveira; Lopes, Bruno Carvalho Portes; Lanchote, Vera Lucia

    2014-03-01

    Rocuronium (ROC) is a neuromuscular blocking agent used in surgical procedures which is eliminated primarily by biliary excretion. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of ROC in human plasma. Separation of ROC and IS (verapamil) was performed using an endcapped C-18 column and a mixture of water:acetonitrile:trifluoracetic acid (50:50:0.1, v/v) as mobile phase. Aliquots of 100 μL of human plasma were extracted at pH 3, using dichloromethane. The lower limit of quantification of 5 ng/mL shows the high sensitivity of this method. Intra- and inter-assay precision (as relative standard deviation) was all ≤14.2% and accuracy (as relative standard error) did not exceed 10.1%. The validated method was successfully applied to quantify ROC concentrations in patients under surgical procedures up to 6h after the administration of the 0.4-0.9 mg/kg ROC. The pharmacokinetic parameter estimations of ROC showed AUC/dose of 563 μg min/mL, total clearance of 2.5 mL/min/kg, volume of distribution at steady state of 190 mL/kg and mean residence time of 83 min.

  17. Simultaneous Determination of Fucoxanthin and Its Deacetylated Metabolite Fucoxanthinol in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Zhang, Yiping; Wu, Hao; Wen, Hongmei; Fang, Hua; Hong, Zhuan; Yi, Ruizao; Liu, Rui

    2015-10-01

    Fucoxanthin and its deacetylated metabolite fucoxanthinol are two major carotenoids that have been confirmed to possess various pharmacological properties. In the present study, fucoxanthinol was identified as the deacetylated metabolite of fucoxanthin, after intravenous (i.v.) and intragastric gavage (i.g.) administration to rats at doses of 2 and 65 mg/kg, respectively, by liquid chromatography-tandem mass spectrometric (LC-MS/MS) analysis. Next, an accurate and precise LC-MS/MS method was developed to quantitatively determine fucoxanthin and fucoxanthinol in rat plasma. Plasma samples were resolved by LC-MS/MS on a reverse-phase SB-C18 column that was equilibrated and eluted with acetonitrile (A)/aqueous 0.1% formic acid (B; 92/8, v/v) at a flow rate of 0.5 mL/min. Analytes were monitored by multiple-reaction monitoring (MRM) under positive electrospray ionization mode. The precursor/product transitions (m/z) were 659.3→109.0 for fucoxanthin, 617.2→109.0 for fucoxanthinol, and 429.4→313.2 for the internal standard (IS). Calibration curves for fucoxanthin and fucoxanthinol were linear over concentrations ranging from 1.53 to 720 and 1.17 to 600 ng/mL, respectively. The inter- and intraday accuracy and precision were within ±15%. The method was applied successfully in a pharmacokinetic study and the resulting oral fucoxanthin bioavailability calculated. PMID:26512677

  18. Liquid chromatography-tandem mass spectroscopy assay for quercetin and conjugated quercetin metabolites in human plasma and urine.

    PubMed

    Wang, Liang; Morris, Marilyn E

    2005-07-25

    A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.

  19. Determination of L-ephedrine, pseudoephedrine, and caffeine in rat plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Cooper, Stephen D; Fletcher, Brenda L; Silinski, Melanie A Rehder; Brown, Sherri S; Lodge, Jon W; Fernando, Reshan A; Collins, Bradley J

    2011-07-01

    A rapid and simple liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of L-ephedrine, pseudoephedrine, and caffeine in male Fisher-344 rat plasma at nanogram-per-milliliter concentrations for use in support of toxicology studies. Only 25 μL of plasma is required, and extraction is performed using a simple, single-step protein precipitation. The method was validated over a range of 2.09 to 5460 ng/mL for L-ephedrine, 2.09 to 5050 ng/mL for pseudoephedrine and 2.03 to 5340 ng/mL for caffeine. A binary gradient elution at 0.3 mL/min was used with a Waters XBridge Phenyl (2.1 × 150 mm, 3.5 μm) column and a Waters XBridge Phenyl 2.1- × 10-mm guard column at ambient temperature. The mobile phase consisted of 10 mM ammonium acetate in water (pH 5.0) and methanol. Caffeine trimethyl-(13)C(3) was used as the internal standard. The method was evaluated for linearity, recovery, precision, accuracy, and stability, and it was successfully applied in toxicokinetic studies of ephedrine, administered alone, in combination with caffeine, and in the herbal source Ma Huang.

  20. Development of a liquid chromatography-tandem mass spectrometry method for the determination of sulfite in food.

    PubMed

    Robbins, Katherine S; Shah, Romina; MacMahon, Shaun; de Jager, Lowri S

    2015-06-01

    Sulfites are widely used food preservatives that can cause severe reactions in sensitive individuals. As a result, the U.S. FDA requires that sulfites be listed on the label of any food product containing >10 mg/kg (ppm) sulfite (measured as sulfur dioxide). Currently, the optimized Monier-Williams (MW) method (AOAC Official Method 990.28) is the most common approach for determining sulfite concentrations in food samples. However, this method is time-consuming and lacks specificity in certain matrices. An improved rapid, sensitive, and selective method has been developed using electrospray ionization (ESI) high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of sulfite in various food matrices. A total of 12 different types of foods were evaluated. These included dried fruits and vegetables, frozen seafood, sweeteners, and juices. The matrix is extracted with a buffered formaldehyde solution, converting free and reversibly bound sulfite to the stable formaldehyde adduct, hydroxymethylsulfonate (HMS). Extracts are prepared for injection using a C18 SPE cartridge to remove any lipophilic compounds. HMS is then separated from other matrix components using hydrophilic interaction chromatography (HILIC) and detected using multiple reaction monitoring (MRM). The method was validated at 5 concentrations in 12 food matrices. Accuracy data showed spiked recoveries ranging from 84 to 115% in representative foods. Six commercially available sulfited products were analyzed using the LC-MS/MS method, as well as the MW method, to determine if differences exist.

  1. Characterization of an Ion Mobility-Multiplexed Collision Induced Dissociation- Tandem Time-of-Flight Mass Spectrometry Approach

    SciTech Connect

    Ibrahim, Yehia M.; Prior, David C.; Baker, Erin Shammel; Smith, Richard D.; Belov, Mikhail E.

    2010-06-01

    The confidence in peptide (and protein) identifications with ion mobility spectrometry time-of-flight mass spectrometry (IMS-TOFMS) is expected to drastically improve with the addition of information from an efficient ion dissociation step prior to MS detection. High throughput IMS-TOFMS analysis imposes a strong need for multiplexed ion dissociation approaches where multiple precursor ions yield complex sets of fragment ions that are often intermingled with each other in both the drift time and m/z domains. We have developed and evaluated a novel approach for collision-induced dissociation (CID) with an IMS-TOFMS instrument. It has been shown that precursor ions activated inside an rf-device with an axial dc-electric field produce abundant fragment ions which are radially confined with the rf-field and collisionally cooled at an elevated pressure, resulting in high CID efficiencies comparable or higher than those measured in triple-quadrupole instruments We have also developed an algorithm for deconvoluting these complex multiplexed tandem MS spectra by clustering both the precursor and fragment ions into the matching drift time profiles and by effectively utilizing high mass measurement accuracy of the TOFMS. In a single IMS separation with a tryptic digest of bovine serum albumin (BSA), we have reliably identified 20 unique peptides using multiplexed CID approach downstream of the IMS separation. Peptides were identified based upon the correlation between the precursor and fragment drift time profiles and by matching the profile representative masses to those of in silico BSA tryptic peptides and their fragments. The false discovery rate (FDR) of peptide identifications from multiplexed MS/MS spectra was less than 1%.

  2. Differentiation of linear and cyclic polymer architectures by MALDI tandem mass spectrometry (MALDI-MS2).

    PubMed

    Yol, Aleer M; Dabney, David E; Wang, Shih-Fan; Laurent, Boyd A; Foster, Mark D; Quirk, Roderic P; Grayson, Scott M; Wesdemiotis, Chrys

    2013-01-01

    [M + Ag](+) ions from cyclic and linear polystyrenes and polybutadienes, formed by matrix-assisted laser desorption ionization (MALDI), give rise to significantly different fragmentation patterns in tandem mass spectrometry (MS(2)) experiments. In both cases, fragmentation starts with homolytic cleavage at the weakest bond, usually a C-C bond, to generate two radicals. From linear structures, the separated radicals depolymerize extensively by monomer losses and backbiting rearrangements, leading to low-mass radical ions and much less abundant medium- and high-mass closed-shell fragments that contain one of the original end groups, along with internal fragments. With cyclic structures, depolymerization is less efficient, as it can readily be terminated by intramolecular H-atom transfer between the still interconnected radical sites (disproportionation). These differences in fragmentation reactivity result in substantially different fragment ion distributions in the MS(2) spectra. Simple inspection of the relative intensities of low- versus high-mass fragments permits conclusive determination of the macromolecular architecture, while full spectral interpretation reveals the individual end groups of linear polymers or the identity of the linker used to form the cyclic polymer. PMID:23192702

  3. Differentiation of Linear and Cyclic Polymer Architectures by MALDI Tandem Mass Spectrometry (MALDI-MS2)

    NASA Astrophysics Data System (ADS)

    Yol, Aleer M.; Dabney, David E.; Wang, Shih-Fan; Laurent, Boyd A.; Foster, Mark D.; Quirk, Roderic P.; Grayson, Scott M.; Wesdemiotis, Chrys

    2013-01-01

    [M + Ag]+ ions from cyclic and linear polystyrenes and polybutadienes, formed by matrix-assisted laser desorption ionization (MALDI), give rise to significantly different fragmentation patterns in tandem mass spectrometry (MS2) experiments. In both cases, fragmentation starts with homolytic cleavage at the weakest bond, usually a C-C bond, to generate two radicals. From linear structures, the separated radicals depolymerize extensively by monomer losses and backbiting rearrangements, leading to low-mass radical ions and much less abundant medium- and high-mass closed-shell fragments that contain one of the original end groups, along with internal fragments. With cyclic structures, depolymerization is less efficient, as it can readily be terminated by intramolecular H-atom transfer between the still interconnected radical sites (disproportionation). These differences in fragmentation reactivity result in substantially different fragment ion distributions in the MS2 spectra. Simple inspection of the relative intensities of low- versus high-mass fragments permits conclusive determination of the macromolecular architecture, while full spectral interpretation reveals the individual end groups of linear polymers or the identity of the linker used to form the cyclic polymer.

  4. Characterization of crude oil biomarkers using comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Mogollón, Noroska Gabriela Salazar; Prata, Paloma Santana; Dos Reis, Jadson Zeni; Neto, Eugênio Vaz Dos Santos; Augusto, Fabio

    2016-09-01

    Oil samples from Recôncavo basin (NE Brazil), previously analyzed by traditional techniques such as gas chromatography coupled to tandem mass spectrometry, were evaluated using comprehensive two-dimensional gas chromatography coupled to quadrupole mass spectrometry and comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry along with simplified methods of samples preparation to evaluate the differences and advantages of these analytical techniques to better understand the development of the organic matter in this basin without altering the normal distribution of the compounds in the samples. As a result, the geochemical parameters calculated by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry described better the origin, maturity, and biodegradation of both samples probably by increased selectivity, resolution, and sensitivity inherent of the multidimensional technique. Additionally, the detection of the compounds such as, the C(14α-) homo-26-nor-17α-hopane series, diamoretanes, nor-spergulanes, C19 -C26 A-nor-steranes and 4α-methylsteranes resolved and detected by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry were key to classify and differentiate these lacustrine samples according to their maturity and deposition conditions.

  5. Improved mass resolution and mass accuracy in TOF-SIMS spectra and images using argon gas cluster ion beams.

    PubMed

    Shon, Hyun Kyong; Yoon, Sohee; Moon, Jeong Hee; Lee, Tae Geol

    2016-06-09

    The popularity of argon gas cluster ion beams (Ar-GCIB) as primary ion beams in time-of-flight secondary ion mass spectrometry (TOF-SIMS) has increased because the molecular ions of large organic- and biomolecules can be detected with less damage to the sample surfaces. However, Ar-GCIB is limited by poor mass resolution as well as poor mass accuracy. The inferior quality of the mass resolution in a TOF-SIMS spectrum obtained by using Ar-GCIB compared to the one obtained by a bismuth liquid metal cluster ion beam and others makes it difficult to identify unknown peaks because of the mass interference from the neighboring peaks. However, in this study, the authors demonstrate improved mass resolution in TOF-SIMS using Ar-GCIB through the delayed extraction of secondary ions, a method typically used in TOF mass spectrometry to increase mass resolution. As for poor mass accuracy, although mass calibration using internal peaks with low mass such as hydrogen and carbon is a common approach in TOF-SIMS, it is unsuited to the present study because of the disappearance of the low-mass peaks in the delayed extraction mode. To resolve this issue, external mass calibration, another regularly used method in TOF-MS, was adapted to enhance mass accuracy in the spectrum and image generated by TOF-SIMS using Ar-GCIB in the delayed extraction mode. By producing spectra analyses of a peptide mixture and bovine serum albumin protein digested with trypsin, along with image analyses of rat brain samples, the authors demonstrate for the first time the enhancement of mass resolution and mass accuracy for the purpose of analyzing large biomolecules in TOF-SIMS using Ar-GCIB through the use of delayed extraction and external mass calibration.

  6. Electrospray ionization-tandem mass spectrometry method for differentiating chlorine substitution in disinfection byproduct formation.

    PubMed

    Deng, Zhuo; Yang, Xin; Shang, Chii; Zhang, Xiangru

    2014-05-01

    An electrospray ionization-tandem mass spectrometry (ESI-tqMS) method was developed to identify the location of chlorine substitution during the chlorination of model organic compounds. The chlorine substitution in the aliphatic part and that in the benzene ring of an organic molecule can be differentiated by their corresponding ranges of optimum collision energies, 5-7 eV and over 15 eV, respectively, in the precursor ion scan of m/z 35. The method was applied to predict the structures of intermediates and reveal the transformation pathways during the chlorination of 4-amino-2-chlorobenzoic acid and phenylalanine as a function of reaction time and the chlorine-to-precursor ratio. In the case of phenylalanine, chlorine was found to replace one hydrogen atom attached to the aliphatic nitrogen; in the case of 4-amino-2-chlorobenzoic acid, chlorine was found to replace the hydrogen atoms attached to the aromatic rings.

  7. Eddy correlation fluxes of trace gases using a tandem mass spectrometer

    NASA Astrophysics Data System (ADS)

    Shaw, William J.; Spicer, Chester W.; Kenny, Donald V.

    This paper describes a field evaluation of a tandem mass spectrometer (TAGA) for use in measuring turbulence fluxes of trace gases. Measurements were made over a two-day period in a fallow farm field west of Columbus, OH. The results show that for weakly adsorbing species such as acetone, the effective time constant for the TAGA is <0.1 s, and the device can be used for eddy correlation flux measurements with little need for corrections. The effective time constant is longer for adsorbing species, such as ammonia, but spectral corrections can permit flux estimates for these species as well. This paper presents the first reported measurements of fluxes of acetone, formic acid, and ammonia using the eddy correlation technique.

  8. Determination of amphetamine and methamphetamine in umbilical cord using liquid chromatography-tandem mass spectrometry

    PubMed Central

    Jones, Joseph; Rios, Rosemarie; Jones, Mary; Lewis, Douglas; Plate, Charles

    2009-01-01

    The use of meconium as a drug-screening matrix for newborns has been the gold standard of care for the past two decades. A recent study using matched pairs of meconium and umbilical cord demonstrated a high degree of agreement. The use of liquid chromatography-tandem mass spectrometry as a means to confirm amphetamines presumptive positive umbilical cord specimens for amphetamine and methamphetamine is described here for the first time. The limit of detection for both compounds was 0.2 ng/g. The limit of quantitation for both compounds was 0.6 ng/g. The assay was linear for both compounds up to 100 ng/g. PMID:19783234

  9. Lipidomic Analysis of Twenty Seven Prostanoids and Isoprostanes by Electrospray Liquid Chromatography/Tandem Mass Spectrometry

    PubMed Central

    Masoodi, Mojgan; Nicolaou, Anna

    2006-01-01

    Prostanoids are potent mediators of many physiological and pathophysiological processes. Of the many analytical methodologies used for their qualitative and quantitative analysis, electrospray tandem mass spectrometry coupled to liquid chromatography (ESI-LC-MS/MS) offers a rapid, sensitive and versatile system applicable to lipidomic analyses. We have developed an ESI-LC-MS/MS assay for twenty-seven mediators including prostaglandins, prostacyclines, thromboxanes, dihydroprostaglandins and isoprostanes. The assay was liner over the concentration range 1-100 pg/μL. The limits of detection and quantitation were 0.5-50 pg and 2-100 pg respectively, whilst recoveries were from 83-116 % depending on the metabolite. The assay can be applied to profiling prostanoids produced by a variety of biological fluids and extracts including brain, liver, plasma and urine, facilitating thus our understanding of the role of these lipid mediators in health and disease, as well as assisting in drug development. PMID:16986207

  10. Characterization of protein N-glycosylation by tandem mass spectrometry using complementary fragmentation techniques

    DOE PAGES

    Ford, Kristina L.; Zeng, Wei; Heazlewood, Joshua L.; Bacic, Antony

    2015-08-28

    The analysis of post-translational modifications (PTMs) by proteomics is regarded as a technically challenging undertaking. While in recent years approaches to examine and quantify protein phosphorylation have greatly improved, the analysis of many protein modifications, such as glycosylation, are still regarded as problematic. Limitations in the standard proteomics workflow, such as use of suboptimal peptide fragmentation methods, can significantly prevent the identification of glycopeptides. The current generation of tandem mass spectrometers has made available a variety of fragmentation options, many of which are becoming standard features on these instruments. Lastly, we have used three common fragmentation techniques, namely CID, HCD,more » and ETD, to analyze a glycopeptide and highlight how an integrated fragmentation approach can be used to identify the modified residue and characterize the N-glycan on a peptide.« less

  11. Characterization of protein N-glycosylation by tandem mass spectrometry using complementary fragmentation techniques

    SciTech Connect

    Ford, Kristina L.; Zeng, Wei; Heazlewood, Joshua L.; Bacic, Antony

    2015-08-28

    The analysis of post-translational modifications (PTMs) by proteomics is regarded as a technically challenging undertaking. While in recent years approaches to examine and quantify protein phosphorylation have greatly improved, the analysis of many protein modifications, such as glycosylation, are still regarded as problematic. Limitations in the standard proteomics workflow, such as use of suboptimal peptide fragmentation methods, can significantly prevent the identification of glycopeptides. The current generation of tandem mass spectrometers has made available a variety of fragmentation options, many of which are becoming standard features on these instruments. Lastly, we have used three common fragmentation techniques, namely CID, HCD, and ETD, to analyze a glycopeptide and highlight how an integrated fragmentation approach can be used to identify the modified residue and characterize the N-glycan on a peptide.

  12. Multidetection of antibiotics in liver tissue by ultra-high-pressure-liquid-chromatography-tandem mass spectrometry.

    PubMed

    Freitas, Andreia; Barbosa, Jorge; Ramos, Fernando

    2015-01-22

    A multiresidue quantitative screening method covering 39 antibiotics from 7 different families by ultra-high-pressure-liquid-chromatography-tandem mass spectrometry (UHPLC-MS/MS) is described. Sulfonamides, trimethoprim, tetracyclines, macrolides, quinolones, penicillins and chloramphenicol are simultaneously detected in liver tissue. A simple sample treatment method consisting of extraction with a mixture of acetonitrile and ethylenediaminetetraacetic acid (EDTA) followed by solid-phase extraction (SPE) with a hydrophilic-lipophilic balanced (HLB) cartridge was developed. The methodology was validated, in accordance with Decision 2002/657/EC, by evaluating the following required parameters: decision limit (CCα), detection capability (CCβ), specificity, repeatability and reproducibility. The precision, in terms of the relative standard deviation, was under 22% for all of the compounds, and the recoveries were between 80% and 110%. The CCα and CCβ were determined according to the maximum residue limit (MRL) or the minimum required performance limit (MRPL), when established.

  13. Protonation Sites, Tandem Mass Spectrometry and Computational Calculations of o-Carbonyl Carbazolequinone Derivatives.

    PubMed

    Martínez-Cifuentes, Maximiliano; Clavijo-Allancan, Graciela; Zuñiga-Hormazabal, Pamela; Aranda, Braulio; Barriga, Andrés; Weiss-López, Boris; Araya-Maturana, Ramiro

    2016-01-01

    A series of a new type of tetracyclic carbazolequinones incorporating a carbonyl group at the ortho position relative to the quinone moiety was synthesized and analyzed by tandem electrospray ionization mass spectrometry (ESI/MS-MS), using Collision-Induced Dissociation (CID) to dissociate the protonated species. Theoretical parameters such as molecular electrostatic potential (MEP), local Fukui functions and local Parr function for electrophilic attack as well as proton affinity (PA) and gas phase basicity (GB), were used to explain the preferred protonation sites. Transition states of some main fragmentation routes were obtained and the energies calculated at density functional theory (DFT) B3LYP level were compared with the obtained by ab initio quadratic configuration interaction with single and double excitation (QCISD). The results are in accordance with the observed distribution of ions. The nature of the substituents in the aromatic ring has a notable impact on the fragmentation routes of the molecules. PMID:27399676

  14. Multiclass method for antimicrobial analysis in animal feeds by liquid chromatography-tandem mass spectrometry.

    PubMed

    Borràs, S; Companyó, R; Guiteras, J; Bosch, J; Medina, M; Termes, S

    2013-10-01

    A rapid multiclass method that covers 50 antimicrobials from 13 different families in animal feeds was developed. Samples were extracted using a mixture of methanol, acetonitrile and a McIlvaine buffer combined with sonication. Feed extracts were simply diluted prior to injection, since the clean-up strategies that were tested, based on either solid-phase extraction or dispersive solid-phase extraction, were ineffective at minimizing matrix-related signal suppression/enhancement. Analysis was carried out by liquid chromatography coupled to tandem mass spectrometry using an electrospray ionization source operating in positive and negative modes. For the quantification, matrix-fortified standard calibration curves were used to compensate for matrix effects and losses in sample preparation. The method was validated in-house in pig, poultry and cattle feed matrices and showed satisfactory performance characteristics. Thus, the proposed approach was suitable for application in a routine high-throughput laboratory for the official control of feeds.

  15. Protonation Sites, Tandem Mass Spectrometry and Computational Calculations of o-Carbonyl Carbazolequinone Derivatives

    PubMed Central

    Martínez-Cifuentes, Maximiliano; Clavijo-Allancan, Graciela; Zuñiga-Hormazabal, Pamela; Aranda, Braulio; Barriga, Andrés; Weiss-López, Boris; Araya-Maturana, Ramiro

    2016-01-01

    A series of a new type of tetracyclic carbazolequinones incorporating a carbonyl group at the ortho position relative to the quinone moiety was synthesized and analyzed by tandem electrospray ionization mass spectrometry (ESI/MS-MS), using Collision-Induced Dissociation (CID) to dissociate the protonated species. Theoretical parameters such as molecular electrostatic potential (MEP), local Fukui functions and local Parr function for electrophilic attack as well as proton affinity (PA) and gas phase basicity (GB), were used to explain the preferred protonation sites. Transition states of some main fragmentation routes were obtained and the energies calculated at density functional theory (DFT) B3LYP level were compared with the obtained by ab initio quadratic configuration interaction with single and double excitation (QCISD). The results are in accordance with the observed distribution of ions. The nature of the substituents in the aromatic ring has a notable impact on the fragmentation routes of the molecules. PMID:27399676

  16. Protonation Sites, Tandem Mass Spectrometry and Computational Calculations of o-Carbonyl Carbazolequinone Derivatives.

    PubMed

    Martínez-Cifuentes, Maximiliano; Clavijo-Allancan, Graciela; Zuñiga-Hormazabal, Pamela; Aranda, Braulio; Barriga, Andrés; Weiss-López, Boris; Araya-Maturana, Ramiro

    2016-07-05

    A series of a new type of tetracyclic carbazolequinones incorporating a carbonyl group at the ortho position relative to the quinone moiety was synthesized and analyzed by tandem electrospray ionization mass spectrometry (ESI/MS-MS), using Collision-Induced Dissociation (CID) to dissociate the protonated species. Theoretical parameters such as molecular electrostatic potential (MEP), local Fukui functions and local Parr function for electrophilic attack as well as proton affinity (PA) and gas phase basicity (GB), were used to explain the preferred protonation sites. Transition states of some main fragmentation routes were obtained and the energies calculated at density functional theory (DFT) B3LYP level were compared with the obtained by ab initio quadratic configuration interaction with single and double excitation (QCISD). The results are in accordance with the observed distribution of ions. The nature of the substituents in the aromatic ring has a notable impact on the fragmentation routes of the molecules.

  17. Tandem Mass Spectrometry Detection of Quorum Sensing Activity in Multidrug Resistant Clinical Isolate Acinetobacter baumannii

    PubMed Central

    Chan, Kok-Gan; Cheng, Huey Jia; Chen, Jian Woon; Yin, Wai-Fong; Ngeow, Yun Fong

    2014-01-01

    Many Proteobacteria communicate via production followed by response of quorum sensing molecules, namely, N-acyl homoserine lactones (AHLs). These molecules consist of a lactone moiety with N-acyl side chain with various chain lengths and degrees of saturation at C-3 position. AHL-dependent QS is often associated with regulation of diverse bacterial phenotypes including the expression of virulence factors. With the use of biosensor and high resolution liquid chromatography tandem mass spectrometry, the AHL production of clinical isolate A. baumannii 4KT was studied. Production of short chain AHL, namely, N-hexanoyl-homoserine lactone (C6-HSL) and N-octanoyl-homoserine lactone (C8-HSL), was detected. PMID:25101326

  18. Determination of ethylglucuronide in oral fluid by ultra-performance liquid chromatography- tandem mass spectrometry.

    PubMed

    Hegstad, S; Johnsen, L; Mørland, J; Christophersen, A S

    2009-05-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of ethylglucuronide (EtG) in oral fluid. Sample clean-up was achieved by solid-phase extraction with a Hyper-SEP SAX column. Negative ionization was performed in the multiple reaction monitoring mode. Two transitions were monitored for the analyte and one for the internal standard EtG-d(5). The calibration range was 4.4-222 ng/mL. The recovery of the analyte ranged from 86 to 99%, and the between-assay precisions ranged from 5 to 9% RSD. The limit of quantification was found to be 4.4 ng/mL. The concentration of EtG in oral fluid collected 2-14 h after a moderate alcohol intake varied from 13.3 to 57.7 ng/mL. PMID:19470222

  19. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    PubMed

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were <0.2-2.3 µg/L. The results of the present study indicated that the proposed method was suitable for determining bromate concentrations in drinking water without sample pretreatment.

  20. Analysis of RNA modifications by liquid chromatography-tandem mass spectrometry.

    PubMed

    Thüring, Kathrin; Schmid, Katharina; Keller, Patrick; Helm, Mark

    2016-09-01

    The analysis of RNA modifications is of high importance in order to address a wide range of biological questions. Therefore, a highly sensitive and accurate method such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) has to be available. By using different LC-MS/MS procedures, it is not only possible to quantify very low amounts of RNA modifications, but also to detect probably unknown modified nucleosides. For these cases the dynamic multiple reaction monitoring and the neutral loss scan are the most common techniques. Here, we provide the whole workflow for analyzing RNA samples regarding their modification content. This includes an equipment list, the preparation of required solutions/enzymes and the creation of an internal standard or nucleoside stocks for internal or external calibration. Furthermore, we describe the preparation of RNA samples for the subsequent LC-MS/MS analysis and the corresponding analysis process. PMID:27020891

  1. Multiresidue analysis of pesticides with hydrolyzable functionality in cooked vegetables by liquid chromatography tandem mass spectrometry.

    PubMed

    Lee, Sung Joong; Park, Semin; Choi, Jin Young; Shim, Jae-Han; Shin, Eun-Ho; Choi, Jeong-Heui; Kim, Soo Taek; Abd El-Aty, A M; Jin, Jong Sung; Bae, Dong Won; Shin, Sung Chul

    2009-07-01

    It would be preferable for pesticide residues substituted by hydrolyzable functionality to be analyzed after cooking because their structures are apt to degrade during boiling and/or heating. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantitative determination of 44 pesticide residues with hydrolyzable functional group in five typical vegetable widely consumed in Republic of Korea is described. The sample clean-up was carried out according to the method of Food Code No. 83 established by the Korea Food and Drug Administration (KFDA). Zorbox XDB-C(18) column was selected for the analysis because of the best peak separation. The LC mobile phase consisted of water and 5 mm methanolic ammonium formate, which resulted in a peak shape with good symmetry at each run. Tandem mass spectroscopic (MS/MS) experiments were performed in ESI positive mode and the multiple reaction monitoring modes. A conventional matrix effect was modified to more comprehensive form 100gamma(ij) (%). A high matrix effect (<-30%) was detected for the seven polar pesticides, namely thiamethoxam, clothianidin, acetamiprid, aldicarb, thiacloprid, pirimicarb and methabenzthiazuron. The limits of detection were in the range of 0.1-8.1 microg/kg, indicating a good sensitivity. Most of the recoveries ranged from 70 to 131% with RSDs

  2. Acute neurotoxicity associated with recreational use of methylmethaqualone confirmed by liquid chromatography tandem mass spectrometry.

    PubMed

    Ceschi, A; Giardelli, G; Müller, D M; Elavumkudy, S; Manini, A F; Rauber-Lüthy, C; Hofer, K E

    2013-01-01

    Methylmethaqualone is a sedative designer drug created by adding a methyl group to the 3-phenyl ring of methaqualone, and is at present not subject to restrictive regulation in many countries. To our knowledge, no case of methylmethaqualone abuse has been published to date in the scientific literature, and the only sources of information are users' reports on Web discussion forums and data from preclinical animal studies. We report a case of oral methylmethaqualone abuse confirmed by liquid chromatography tandem mass spectrometry in a 24-year-old previously healthy Caucasian male. Observed symptoms and signs such as central nervous system depression alternating with excitation, psychomotor agitation, muscle hyperactivity, and tachycardia were compatible with methaqualone-induced adverse effects. Except for the mild tachycardia (115 beats/min), other vital signs were normal: blood pressure 134/89 mmHg, body temperature 36.2°C (97.16°F), and peripheral oxygen saturation 99% while breathing room air. The ECG showed no prolongation of the QT interval and the QRS duration was normal. Laboratory analysis revealed a slight increase in creatine kinase (368 U/L) and alanine aminotransferase (90 U/L) serum concentrations. Blood alcohol concentration was 0.32 g/L. Methylmethaqualone was identified in a serum sample collected on admission which was analyzed by a liquid chromatography tandem mass spectrometry toxicological screening method using turbulent flow online extraction. After a few days the patient ingested the same amount of substance with identical symptoms. Based on the chemical structure and animal data, and according to this case report and users' Web reports, methylmethaqualone appears to have a similar acute toxicity profile to methaqualone, with marked psychomotor stimulation. Symptoms of acute toxicity can be expected to resolve with supportive care.

  3. Quantification of Polybrominated and Polychlorinated Biphenyls in Human Matrices by Isotope-Dilution Gas Chromatography-Tandem Mass Spectrometry.

    PubMed

    Marder, M Elizabeth; Panuwet, Parinya; Hunter, Ronald E; Ryan, P Barry; Marcus, Michele; Barr, Dana Boyd

    2016-09-01

    We have developed a highly sensitive and selective analytical method capable of quantifying a total of 15 polybrominated and polychlorinated biphenyls (11 PBBs and 4 PCBs) in human serum. Samples were subjected to liquid-liquid extraction followed by solid-phase extraction prior to measurement using gas chromatography-tandem mass spectrometry in multiple reaction monitoring mode. Quantification was performed using isotope-dilution calibration covering a concentration range of 0.005-12.5 ng/mL. Limits of detection for all target compounds were in the low range (0.7-6.5 pg/mL). The method was validated using in-house pooled human serum fortified at two concentrations (0.5 ng/mL and 1.0 ng/mL), whole semen fortified at one concentration (0.25 ng/mL), and NIST Standard Reference Material (SRM) 1958, which includes five of the target compounds. Method accuracies for all target compounds ranged from 84 to 119% with relative standard deviations (RSDs) of <19%. The measured values for the five target compounds present in the SRM agreed with the certified reference values (89-119% accuracy with RSDs <9%). As this method was developed to support ongoing epidemiologic investigations, we evaluated its suitability by analyzing subsets of serum and whole semen samples from the Michigan PBB Registry cohort. PBB-153, PCB-118, PCB-138, PCB-153 and PCB-180 were detected in all serum samples analyzed, with PBB-77 and PBB-101 detected less frequently in serum. PBB-153, PCB-118, PCB-138, PCB-153 and PCB-180 were detected in at least one whole semen sample. PMID:27445313

  4. Liquid chromatography tandem mass spectrometry method for characterization of monoaromatic nitro-compounds in atmospheric particulate matter.

    PubMed

    Kitanovski, Zoran; Grgić, Irena; Vermeylen, Reinhilde; Claeys, Magda; Maenhaut, Willy

    2012-12-14

    Nitrogen-containing organic compounds in the atmosphere have drawn attention owing to their impact on aerosol chemistry and physics and their potential adverse effects on the biosphere. Among them, nitrocatechols and their homologs have recently been associated with biomass burning. In the present study, nitrocatechols, nitrophenols, nitroguaiacols and nitrosalicylic acids (NSAs) were simultaneously quantified for the first time by using a new analytical method based on liquid chromatography/tandem mass spectrometry, which was systematically optimized and validated. Several analyte specific issues regarding the sample preparation and chromatographic analysis were addressed in order to ensure method sensitivity, precision, and accuracy. Sample matrix effects were thoroughly investigated in order to ensure method specificity. The method was found to be sensitive with limits of detection ranging from 0.1 to 1.0 μg L(-1), and with accuracy generally between 90 and 104%. The relative standard deviations for repeatability and intermediate precision were better than 4% and 9%, respectively. The method was applied to the analysis of winter and summer PM(10) samples from the city of Ljubljana, Slovenia. Aerosol concentrations as high as 152 and 134 ng m(-3) were obtained for the major aerosol nitro-aromatics: 4-nitrocatechol (4NC) and methyl-nitrocatechols (MNCs), respectively. Up to 500-times higher concentrations of 4NC and MNCs were found in winter compared to summer aerosols. The correlation analysis for winter samples showed that 4NC, MNCs, and NSAs are strongly inter-correlated (R(2)=0.84-0.96). Significant correlations between these analytes and anhydrosugars support their proposed origin from biomass burning. The studied nitro-aromatics were found to constitute a non-negligible fraction (around 1%) of the organic carbon. PMID:23122275

  5. Determination of propofol glucuronide from hair sample by using mixed mode anion exchange cartridge and liquid chromatography tandem mass spectrometry.

    PubMed

    Kwak, Jae-Hwan; Kim, Hye Kyung; Choe, Sanggil; In, Sangwhan; Pyo, Jae Sung

    2016-03-15

    The main objective of this study was to develop and validate a simpler and less time consuming analytical method for determination of propofol glucuronide from hair sample, by using mixed mode anion exchange cartridge and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The study uses propofol glucuronide, a major metabolite of propofol, as a marker for propofol abuse. The hair sample was digested in sodium hydroxide solution and loaded in mixed-mode anion cartridge for solid phase extraction. Water and ethyl acetate were used as washing solvents to remove interfering substances from the hair sample. Consequently, 2% formic acid in ethyl acetate was employed to elute propofol glucuronide from the sorbent of mixed-mode anion cartridge, and analyzed by LC-MS/MS. The method validation parameters such as selectivity, specificity, LOD, LLOQ, accuracy, precision, recovery, and matrix effect were also tested. The linearity of calibration curves showed good correlation, with correlation coefficient 0.998. The LOD and LLOQ of the propofol glucuronide were 0.2 pg/mg and 0.5 pg/mg, respectively. The intra and inter-day precision and accuracy were acceptable within 15%. The mean values of recovery and matrix effect were in the range of 91.7-98.7% and 87.5-90.3%, respectively, signifying that the sample preparation, washing and extraction procedure were efficient, and there was low significant hair matrix effect for the extraction of propofol glucuronide from hair sample on the mixed mode anion cartridge. To evaluate the suitability of method, the hair of propofol administered rat was successfully analyzed with this method.

  6. Rapid confirmatory method for the determination of 11 nitroimidazoles in egg using liquid chromatography tandem mass spectrometry.

    PubMed

    Cronly, Mark; Behan, Patrice; Foley, Barry; Malone, Edward; Regan, Liam

    2009-11-13

    A rapid confirmatory method has been developed and validated for the simultaneous identification, confirmation and quantitation of 11 nitroimidazoles in eggs by liquid chromatography tandem mass spectrometry (LC-MS/MS). The method is validated in accordance with Commission Decision 2002/657/EC and is capable of analysing metronidazole (MNZ), dimetridazole (DMZ), ronidazole (RNZ), ipronidazole (IPZ) and their hydroxy metabolites MNZ-OH, HMMNI (hydroxymethyl, methyl nitroimidazole), IPZ-OH. The method is also capable of analysing carnidazole (CRZ), ornidazole (ORZ), tinidazole (TNZ) and ternidazole (TRZ). MNZ, DMZ and RNZ have been assigned a recommended level (RL) of 3 microg kg(-1) by the Community Reference Laboratory (CRL) in Berlin. The developed method described in this study is easily able to detect all the nitroimidazole compounds investigated at this level and below. Egg samples are extracted with acetonitrile, and NaCl is added to help remove matrix contaminants. The acetonitrile extract undergoes a liquid-liquid wash step with hexane; it is then evaporated and reconstituted in mobile phase. The reconstituted samples are analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS). The decision limits (CCalpha) range from 0.33 to 1.26 microg kg(-1) and the detection capabilities (CCbeta), range from 0.56 to 2.15 microg kg(-1). The results of the in ter-assay study, which was performed by fortifying hen egg samples (n=18) on three separate days, show the accuracy calculated for the various analytes to range between 87.2 and 106.2%. The precision of the method, expressed as %CV values for the inter-assay variation of each analyte at the three levels of fortification (3, 4.5 and 6.0 microg kg(-1)), ranged between 3.7 and 11.3%. A Day 4 analysis was carried out to examine species variances in eggs from different birds such as duck and quail and investigating differences in various battery and free range hen eggs.

  7. Simultaneous measurement of aldosterone and cortisol by high-performance liquid chromatography-tandem mass spectrometry: application to dehydration-rehydration studies.

    PubMed

    Taylor, Paul J; van Rosendal, Simon P; Coombes, Jeff S; Gordon, Richard D; Stowasser, Michael

    2010-05-01

    Aldosterone and cortisol are useful biomarkers of dehydration and stress, respectively. The aim of this study was to develop an HPLC-tandem mass spectrometric method for the simultaneous measurement of aldosterone and cortisol in human plasma that could be applied to the study of athletes undergoing exercise and rehydration. Samples were prepared and analysed using an on-line sample preparation/HPLC system coupled to a triple quadrupole tandem-mass spectrometer. Samples (200 microL) were pre-treated and extracted on Hysphere C18 HD cartridges (7 microm, Spark Holland). Chromatography was performed on a Sunfire C18 analytical column (50 mm x 3.0 mm, 3 microm, Waters) under isocratic conditions at a flow rate of 0.3 mL/min. The mobile phase consisted of 35% acetonitrile/water. Mass spectrometric detection was by selected reaction monitoring using negative electrospray ionization conditions. The assay had an analytical range of 25-500 pg/mL and 25-500 ng/mL for aldosterone and cortisol, respectively (r(2)>0.992, n=22). Inter-day accuracy and imprecision for quality control samples was 99.4-106% and <16%, respectively (n=10). In a study of nine human subjects, both aldosterone and cortisol concentrations reflected the expected physiological responses to dehydration, rehydration and exercise when measured by this method. The reported method is suitable to facilitate the study of athletes undergoing dehydration and rehydration protocols.

  8. Liquid chromatography with tandem mass spectrometry quantification of urinary proanthocyanin A2 dimer and its potential use as a biomarker of cranberry intake.

    PubMed

    Walsh, Jason M; Ren, Xiaobai; Zampariello, Carly; Polasky, Daniel A; McKay, Diane L; Blumberg, Jeffrey B; Chen, C-Y Oliver

    2016-01-01

    The lack of a biomarker for the consumption of cranberries has confounded the interpretation of several studies investigating the effect of cranberry products, especially juices, on health outcomes. The objectives of this pilot study were to develop a liquid chromatography tandem mass spectrometric method for the quantification of the proanthocyanin dimer A-2 in human urine and validate urinary proanthocyanin dimer A-2 as a biomarker of cranberry intake. Five healthy, nonsmoking, premenopausal women (20-30 years of age, body mass index: 18.5-25 kg/m(2) ) were assigned to consume a cranberry beverage containing 140 mg proanthocyanin and 35 kilocalories at 237 mL/day, according to a weekly dosing schedule for 7 weeks. Eleven 24 h and morning spot urine samples each were collected from each subject. A reliable, sensitive method for the detection of proanthocyanin dimer A-2 in urine using liquid chromatography with tandem mass spectrometry was developed with a limit of quantitation of 0.25 ng/mL and a relative standard deviation of 7.26%, precision of 5.7%, and accuracy of 91.7%. While proanthocyanin dimer A-2 was quantifiable in urine, it did not appear to be excreted in a concentration that corresponded to the dosing schedule and intake of cranberry juice. PMID:26573891

  9. Liquid chromatography with tandem mass spectrometry quantification of urinary proanthocyanin A2 dimer and its potential use as a biomarker of cranberry intake.

    PubMed

    Walsh, Jason M; Ren, Xiaobai; Zampariello, Carly; Polasky, Daniel A; McKay, Diane L; Blumberg, Jeffrey B; Chen, C-Y Oliver

    2016-01-01

    The lack of a biomarker for the consumption of cranberries has confounded the interpretation of several studies investigating the effect of cranberry products, especially juices, on health outcomes. The objectives of this pilot study were to develop a liquid chromatography tandem mass spectrometric method for the quantification of the proanthocyanin dimer A-2 in human urine and validate urinary proanthocyanin dimer A-2 as a biomarker of cranberry intake. Five healthy, nonsmoking, premenopausal women (20-30 years of age, body mass index: 18.5-25 kg/m(2) ) were assigned to consume a cranberry beverage containing 140 mg proanthocyanin and 35 kilocalories at 237 mL/day, according to a weekly dosing schedule for 7 weeks. Eleven 24 h and morning spot urine samples each were collected from each subject. A reliable, sensitive method for the detection of proanthocyanin dimer A-2 in urine using liquid chromatography with tandem mass spectrometry was developed with a limit of quantitation of 0.25 ng/mL and a relative standard deviation of 7.26%, precision of 5.7%, and accuracy of 91.7%. While proanthocyanin dimer A-2 was quantifiable in urine, it did not appear to be excreted in a concentration that corresponded to the dosing schedule and intake of cranberry juice.

  10. Determination of Synacthen in urine for sports drug testing by means of nano-ultra-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Thomas, Andreas; Kohler, Maxie; Schänzer, Wilhelm; Kamber, Matthias; Delahaut, Philippe; Thevis, Mario

    2009-09-01

    Doping control analysis of performance-enhancing peptides in urine represents a challenging requirement in modern sports drug testing. Low dosing, effective metabolism and short half-life lead to target concentrations in the low fmol/mL range in urine. Synthetic adrenocorticotropic hormone (1-24, Syn-ACTH-en) shares all these characteristics and improved analytical performance is required for its sufficient determination by means of liquid chromatography/tandem mass spectrometry (LC/MS/MS). The desired effects for cheating sportsmen are mainly due to enhanced release of corticosteroids as well as androgenic steroids into the circulation after systemic administration of the drug. Immunoaffinity purification with coated magnetic beads and subsequent liquid chromatography with nano-ultra-performance liquid chromatography (UPLC) coupled to tandem mass spectrometry (high resolution/high mass accuracy) of Synacthen from urinary specimens is described in the present study. The general proof of principle was obtained by analysis of excretion study urine samples and validation was performed with focus on the limit of detection (3 pg/mL), linearity, precision (<20%), recovery ( approximately 30%), robustness, specificity and stability. For all experiments, the ACTH fragment 1-17 was used as the internal standard.

  11. Determination of nitrofuran and chloramphenicol residues by high resolution mass spectrometry versus tandem quadrupole mass spectrometry.

    PubMed

    Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M

    2015-03-01

    An ultra-high performance liquid chromatography based method, coupled to high resolution mass spectrometry (UHPLC-HRMS), was developed to permit the detection and quantification of various nitrofuran and chloramphenicol residues in a number of animal based food products. This method is based on the hydrolysis of covalently bound metabolites and derivatization with 2-nitrobenzaldehyde. Clean-up is achieved by a liquid/liquid and a reversed phase/solid phase extraction. Not only are the four conventional nitrofurans (nitrofurantoin, furazolidone, nitrofurazone and furaltadone) detected, but also nifursol, nitrovin and nifuroxazide. Furthermore, an underivatizable nitrofuran (nifurpirinol) and another banned drug (chloramphenicol) can be quantified as well. The compounds are detected in the form of their precursor ions, [M+H](+) and [M-H](-), respectively. The mass resolving power of 70,000 FWHM, and the applied mass window ensure sufficient selectivity and sensitivity. Confirmation is obtained by monitoring the HRMS resolved product ions which were derived from the unit-mass resolved precursor ions. The multiplexing capability of the utilized Orbitrap instrument provides not only highly selective, but also sensitive confirmatory signals. This method has been validated according to the CD 2002/657/EC for the following matrices: muscle, liver, kidney, fish, honey, eggs and milk. PMID:25682427

  12. Determination of febuxostat in human plasma using ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Lukram, Ojikumar; Parmar, Shivaji; Hande, Amit

    2013-06-01

    A rapid and sensitive liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of febuxostat in human plasma. The liquid-liquid extraction technique was used for the extraction of febuxostat from human plasma using trandolapril as the internal standard (IS). Chromatography was performed on a ultra-performance liquid chromatography (UPLC) BEH C18, 50 mm X 2.1 mm, 1.7 µm particle size column, with the mobile phase consisting of 0.1% formic acid and acetonitrile (in a 25:75 ratio), followed by detection using mass spectrometry. The method involves a simple reversed isocratic chromatography condition and mass spectrometry detection, which enables detection at sub-microgram levels. The method was validated and the lower limit of quantification for febuxostat was found to be 0.075 µg/ml. The mean recovery for febuxostat ranged from 100.9 to 106.5%. This method increased the sensitivity and selectivity; resulting in high-throughput analysis of febuxostat using commercially available IS for pharmacokinetic, bioavailability, and bioequivalence studies, with a chromatographic run time of 1.5 min only.

  13. Dissociation reactions of protonated anthracycline antibiotics following electrospray ionization-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Sleno, Lekha; Campagna-Slater, Valerie; Volmer, Dietrich A.

    2006-09-01

    Fragmentation pathways of doxorubicin, a common cancer therapy agent, and three closely related analogs (epirubicin, daunorubicin, idarubicin) were compared using electrospray ionization with tandem mass spectrometry. This class of antibiotics with anti-tumour activity has important structural features, with a tetracyclic aromatic, polyketide portion, which is glycosylated with an amino sugar in order to exhibit its biological activity. Collision-induced dissociation spectra revealed very similar product ions for each analog, however, important differences were seen in the relative abundances and the ease at which certain fragments were formed. Fragment ions observed included those from cleavage of the glycosidic bond, loss of the side chain from the aglycone moiety, water losses and loss of a methyl radical. Following cleavage of the glycosidic bond, the charge can either reside on the aglycone portion or the sugar moiety, and each of these primary fragments undergoes several secondary dissociation pathways, depending on the collision energy. By ramping the collision voltage, we were able to correlate the changes in fragmentation behavior with small alterations in the structure of the precursor ion. The detailed study of the fragmentation behavior of doxorubicin was supported by accurate mass measurements, using an electrospray-time of flight instrument, as well as MS3 data from a quadrupole-linear ion trap mass spectrometer. Computational studies were also performed to help explain the role of certain functional groups in the fragmentation reactions.

  14. Analyzing Protease Specificity and Detecting in Vivo Proteolytic Events Using Tandem Mass Spectrometry

    SciTech Connect

    Gupta, Nitin; Hixson, Kim K.; Culley, David E.; Smith, Richard D.; Pevzner, Pavel A.

    2010-07-01

    While trypsin remains the most commonly used protease in mass spectrometry, other proteases may be employed for increasing peptide-coverage or generating overlapping peptides. Knowledge of the accurate specifcity rules of these proteases is helpful for database search tools to detect peptides, and becomes crucial when mass spectrometry is used to discover in vivo proteolytic cleavages. In this study, we use tandem mass spectrometry to analyze the specifcity rules of selected proteases and describe MS- Proteolysis, a software tool for identifying putative sites of in vivo proteolytic cleavage. Our analysis suggests that the specifcity rules for some commonly used proteases can be improved, e.g., we find that V8 protease cuts not only after Asp and Glu, as currently expected, but also shows a smaller propensity to cleave after Gly for the conditions tested in this study. Finally, we show that comparative analysis of multiple proteases can be used to detect putative in vivo proteolytic sites on a proteome-wide scale.

  15. CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD.

    PubMed

    Dereziński, Paweł; Klupczyńska, Agnieszka; Sawicki, Wojciech; Kokot, Zenon J

    2016-01-01

    Creatinine determination in urine is used to estimate the completeness of the 24-h urine collection, compensation for variable diuresis and as a preliminary step in protein profiling in urine. Despite the fact that a wide range of methods of measuring creatinine level in biofluids has been developed, many of them are adversely affected by interfering substances. A new liquid chromatography-tandem mass spectrometry method for creatinine determination in urine has been developed. Chromatographic separation was performed by applying C18 column and a gradient elution. Analyses were carried out on a triple quadrupole mass spectrometer equipped with an electrospray ion source. The developed method was fully validated according to the international guidelines. The quantification range of the method was 5-1500 ng/mL, which corresponds to 1-300 mg/dL in urine. Limit of detection and quantitation were 2 and 5 ng/mL, respectively. Additionally, the comparison of creatinine determination by newly developed method to the colorimetric method was performed. The method enables the determination of creatinine in urine samples with a minimal sample preparation, excellent sensitivity and prominent selectivity. Since mass spectrometry allows to measure a number of compounds simultaneously, a future perspective would be to incorporate the determination of other clinically important compounds excreted in urine. PMID:27180423

  16. Decoding Split and Pool Combinatorial Libraries with Electron-Transfer Dissociation Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Sarkar, Mohosin; Pascal, Bruce D.; Steckler, Caitlin; Aquino, Claudio; Micalizio, Glenn C.; Kodadek, Thomas; Chalmers, Michael J.

    2013-07-01

    Screening of bead-based split and pool combinatorial chemistry libraries is a powerful approach to aid the discovery of new chemical compounds able to interact with, and modulate the activities of, protein targets of interest. Split and pool synthesis provides for large and well diversified chemical libraries, in this case comprised of oligomers generated from a well-defined starting set. At the end of the synthesis, each bead in the library displays many copies of a unique oligomer sequence. Because the sequence of the oligomer is not known at the time of screening, methods for decoding of the sequence of each screening "hit" are essential. Here we describe an electron-transfer dissociation (ETD) based tandem mass spectrometry approach for the decoding of mass-encoded split and pool libraries. We demonstrate that the newly described "chiral oligomers of pentenoic amides (COPAs)" yield non-sequence-specific product ions upon collisional activated dissociation; however, complete sequence information can be obtained with ETD. To aid in the decoding of libraries from MS and MS/MS data, we have incorporated 79Br/81Br isotope "tags" to differentiate N- and C-terminal product ions. In addition, we have created "Hit-Find," a software program that allows users to generate libraries in silico . The user can then search all possible members of the chemical library for those that fall within a user-defined mass error.

  17. Characterization of N,N-dimethyl amino acids by electrospray ionization-tandem mass spectrometry.

    PubMed

    Naresh Chary, V; Sudarshana Reddy, B; Kumar, Ch Dinesh; Srinivas, R; Prabhakar, S

    2015-05-01

    Methylation is an essential metabolic process for a number of critical reactions in the body. Methyl groups are involved in the healthy function of the body life processes, by conducting methylation process involving specific enzymes. In these processes, various amino acids are methylated, and the occurrence of methylated amino acids in nature is diverse. Nowadays, mass-spectrometric-based identification of small molecules as biomarkers for diseases is a growing research. Although all dimethyl amino acids are metabolically important molecules, mass spectral data are available only for a few of them in the literature. In this study, we report synthesis and characterization of all dimethyl amino acids, by electrospray ionization-tandem mass spectrometry (MS/MS) experiments on protonated molecules. The MS/MS spectra of all the studied dimethyl amino acids showed preliminary loss of H2O + CO to form corresponding immonium ions. The other product ions in the spectra are highly characteristic of the methyl groups on the nitrogen and side chain of the amino acids. The amino acids, which are isomeric and isobaric with the studied dimethyl amino acids, gave distinctive MS/MS spectra. The study also included MS/MS analysis of immonium ions of dimethyl amino acids that provide information on side chain structure, and it is further tested to determine the N-terminal amino acid of the peptides.

  18. Liquid chromatography coupled to tandem mass spectrometry for the analysis of acrylamide in typical Spanish products.

    PubMed

    Bermudo, E; Moyano, E; Puignou, L; Galceran, M T

    2008-07-15

    This paper describes the use of liquid chromatography coupled to tandem mass spectrometry for the determination of acrylamide in several typical foods produced and consumed in Spain. Christmas sweets, olives, traditionally made potato crisps, pastry products, sweet fritters ("churros") and one of Spain's most famous dishes, Spanish omelette, were selected. Using the mass spectra information provided by an ion trap analyzer in combination with the accurate mass measurements from time-of-flight (TOF) spectrometry a co-extractive interference present in some potato products was identified as valine. A porous graphitic carbon column, which enabled the co-extractive and acrylamide to be separated, and ion trap or triple quadrupole analyzers, depending on the acrylamide concentration, were used to determine this genotoxic compound in foodstuffs. The highest values were found in potato products, sweet fritters, Christmas sweets and pastry products, with values ranging between 70 and 2000 microg/g. Spanish omelette presented relatively low levels, similar to those obtained for dried fruits.

  19. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Technology Transfer Automated Retrieval System (TEKTRAN)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  20. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  1. Simplified analysis of glyphosate and aminomethylphosphonic acid in water, vegetation, and soil by liquid chromatography-tandem mass spectrometry

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A simple, fast, efficient, and sensitive method was developed for analysis of glyphosate and its degradate, aminomethylphosphonic acid (AMPA), in water, vegetation, and soil. Aqueous extracts were passed through reverse phase and cation exchange columns and directly injected into a tandem mass spect...

  2. Probability-Based Pattern Recognition and Statistical Framework for Randomization: Modeling Tandem Mass Spectrum/Peptide Sequence False Match Frequencies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Estimating and controlling the frequency of false matches between a peptide tandem mass spectrum and candidate peptide sequences is an issue pervading proteomics research. To solve this problem, we designed an unsupervised pattern recognition algorithm for detecting patterns with various lengths fr...

  3. Changes in Kicking Pattern: Effect of Experience, Speed, Accuracy, and Effective Striking Mass

    ERIC Educational Resources Information Center

    Southard, Dan L.

    2014-01-01

    Purpose: The purposes of this study were to: (a) examine the effect of experience and goal constraints (speed, accuracy) on kicking patterns; (b) determine if effective striking mass was independent of ankle velocity at impact; and (c) determine the accuracy of kicks relative to independent factors. Method: Twenty participants were recruited to…

  4. Determination of Dicyandiamide in Powdered Milk Using Direct Analysis in Real Time Quadrupole Time-of-Flight Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Zhang, Liya; Yong, Wei; Liu, Jiahui; Wang, Sai; Chen, Qilong; Guo, Tianyang; Zhang, Jichuan; Tan, Tianwei; Su, Haijia; Dong, Yiyang

    2015-08-01

    The direct analysis in real time (DART) ionization source coupled with quadrupole time-of-flight tandem mass spectrometry (Q-TOF MS/MS) system has the capability to desorb analytes directly from samples without sample cleanup or chromatographic separation. In this work, a method based on DART/Q-TOF MS/MS has been developed for rapid identification of dicyandiamide (DCD) present in powdered milk. Simple sample extraction procedure employing acetonitrile-water (80:20, v/v) mixture was followed by direct, high-throughput determination of sample extracts spread on a steel mesh of the transmission module by mass spectrometry under ambient conditions. The method has been evaluated for both qualitative and quantitative analysis of DCD in powdered milk. Variables including experimental apparatus, DART gas heater temperature, sample presentation speed, and vacuum pressure were investigated. The quantitative method was validated with respect to linearity, sensitivity, repeatability, precision, and accuracy by using external standards. After optimization of these parameters, a limit of detection (LOD) of 100 μg kg-1 was obtained for DCD with a linear working range from 100 to 10000 μg kg-1 and a satisfactory correlation coefficient (R2) of 0.9997. Good recovery (80.08%-106.47%) and repeatability (RSD = 3.0%-5.4%) were achieved for DCD. The DART/Q-TOF MS/MS-based method provides a rapid, efficient, and powerful scheme to analyze DCD in powdered milk with limited sample preparation, thus reducing time and complexity of quality control.

  5. Determination of ginsenoside compound K in human plasma by liquid chromatography–tandem mass spectrometry of lithium adducts

    PubMed Central

    Chen, Yunhui; Lu, Youming; Yang, Yong; Chen, Xiaoyan; Zhu, Liang; Zhong, Dafang

    2015-01-01

    Ginsenoside compound K (GCK), the main metabolite of protopanaxadiol constituents of Panax ginseng, easily produces alkali metal adduct ions during mass spectrometry particularly with lithium. Accordingly, we have developed a rapid and sensitive liquid chromatography–tandem mass spectrometric method for analysis of GCK in human plasma based on formation of a lithium adduct. The analyte and paclitaxel (internal standard) were extracted from 50 µL human plasma using methyl tert-butyl ether. Chromatographic separation was performed on a Phenomenex Gemini C18 column (50 mm×2.0 mm; 5 μm) using stepwise gradient elution with acetonitrile–water and 0.2 mmol/L lithium carbonate at a flow rate of 0.5 mL/min. Detection was performed in the positive ion mode using multiple reaction monitoring of the transitions at m/z 629→449 for the GCK-lithium adduct and m/z 860→292 for the adduct of paclitaxel. The assay was linear in the concentration range 1.00–1000 ng/mL (r2>0.9988) with intra- and inter-day precision of ±8.4% and accuracy in the range of −4.8% to 6.5%. Recovery, stability and matrix effects were all satisfactory. The method was successfully applied to a pharmacokinetic study involving administration of a single GCK 50 mg tablet to healthy Chinese volunteers. PMID:26579476

  6. Simultaneous pharmacokinetic and pharmacodynamic analysis of 5α-reductase inhibitors and androgens by liquid chromatography tandem mass spectrometry.

    PubMed

    Upreti, Rita; Naredo, Gregorio; Faqehi, Abdullah M M; Hughes, Katherine A; Stewart, Laurence H; Walker, Brian R; Homer, Natalie Z M; Andrew, Ruth

    2015-01-01

    Benign prostatic hyperplasia and prostate cancer can be treated with the 5α-reductase inhibitors, finasteride and dutasteride, when pharmacodynamic biomarkers are useful in assessing response. A novel method was developed to measure the substrates and products of 5α-reductases (testosterone, 5α-dihydrotestosterone (DHT), androstenedione) and finasteride and dutasteride simultaneously by liquid chromatography tandem mass spectrometry, using an ABSciex QTRAP(®) 5500, with a Waters Acquity™ UPLC. Analytes were extracted from serum (500 µL) via solid-phase extraction (Oasis(®) HLB), with (13)C3-labelled androgens and d9-finasteride included as internal standards. Analytes were separated on a Kinetex C18 column (150 × 3 mm, 2.6 µm), using a gradient run of 19 min. Temporal resolution of analytes from naturally occurring isomers and mass +2 isotopomers was ensured. Protonated molecular ions were detected in atmospheric pressure chemical ionisation mode and source conditions optimised for DHT, the least abundant analyte. Multiple reaction monitoring was performed as follows: testosterone (m/z 289 → 97), DHT (m/z 291 → 255), androstenedione (m/z 287 → 97), dutasteride (m/z 529 → 461), finasteride (m/z 373 → 317). Validation parameters (intra- and inter-assay precision and accuracy, linearity, limits of quantitation) were within acceptable ranges and biological extracts were stable for 28 days. Finally the method was employed in men treated with finasteride or dutasteride; levels of DHT were lowered by both drugs and furthermore the substrate concentrations increased. PMID:25281165

  7. Enantioselective determination of doxazosin in human plasma by liquid chromatography-tandem mass spectrometry using ovomucoid chiral stationary phase.

    PubMed

    Liu, Ke; Zhong, Dafang; Chen, Xiaoyan

    2010-09-15

    An enantioselective and sensitive method was developed and validated for determination of doxazosin enantiomers in human plasma by liquid chromatography-tandem mass spectrometry. The enantiomers of doxazosin were extracted from plasma using ethyl ether/dichloromethane (3/2, v/v) under alkaline conditions. Baseline chiral separation was obtained within 9 min on an ovomucoid column using an isocratic mobile phase of methanol/5mM ammonium acetate/formic acid (20/80/0.016, v/v/v) at a flow rate of 0.60 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 452-->344 for doxazosin enantiomers, and m/z 384-->247 for prazosin (internal standard). The method was linear in the concentration range of 0.100-50.0 ng/mL for each enantiomer using 200 microL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.100 ng/mL. The intra- and inter-assay precision was 5.0-11.1% and 5.7-7.6% for R-(-)-doxazosin and S-(+)-doxazosin, respectively. The accuracy was 97.4-99.5% for R-(-)-doxazosin and 96.8-102.8% for S-(+)-doxazosin. No chiral inversion was observed during the plasma storage, preparation and analysis. The method proved adequate for enantioselective pharmacokinetic studies of doxazosin after oral administration of therapeutic doses of racemic doxazosin.

  8. Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure.

    PubMed

    Zhang, Tianjiao; Zhang, Chuanbao; Zhao, Haijian; Zeng, Jie; Zhang, Jiangtao; Zhou, Weiyan; Yan, Ying; Wang, Yufei; Wang, Mo; Chen, Wenxiang

    2016-10-01

    Accurate and precise glucose measurements are requisite for ensuring appropriate diagnosis and management of diseases related to hyperglycemia or hypoglycemia. It is necessary to have a higher order method to provide an accuracy base to which routine methods can be compared. We developed and evaluated a highly reliable measurement procedure based on isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) with a simple one-step derivatization. An appropriate amount of serum was accurately weighed and spiked with an isotope-labeled internal standard. After protein precipitation, the supernatant was reacted with 1-phenyl-3-methyl-5-pyrazolone for chemical structural transformation. The glucose derivatives were analyzed with LC-MS/MS in positive electrospray ionization mode. The within-run and total CVs ranged from 0.28 to 0.42 % and from 0.42 to 0.76 %, respectively, for a concentration range of 1.691 to 15.676 mmol/L. A regression comparison of the presented method to an existing RMP based on ID GC-MS showed agreement with no statistical difference (Y = 0.9985X-0.008; 95 % CI for the slope, 0.9966 to 1.001; 95 % CI for the intercept, -0.012 to 0.019). The structural analogs of glucose with a molecular mass of 180 were tested, and no significant interference effect was found. The limit of quantification was estimated to 0.8 ng glucose in absolute amount. This method is accurate, simple, and can serve as a candidate reference measurement procedure (RMP) in the establishment of a serum glucose reference system. PMID:27481169

  9. Total microcystins analysis in water using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    PubMed

    Roy-Lachapelle, Audrey; Fayad, Paul B; Sinotte, Marc; Deblois, Christian; Sauvé, Sébastien

    2014-04-11

    A new approach for the analysis of the cyanobacterial microcystins (MCs) in environmental water matrices has been developed. It offers a cost efficient alternative method for the fast quantification of total MCs using mass spectrometry. This approach permits the quantification of total MCs concentrations without requiring any derivatization or the use of a suite of MCs standards. The oxidation product 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) was formed through a Lemieux oxidation and represented the total concentration of free and bound MCs in water samples. MMPB was analyzed using laser diode thermal desorption-atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). LDTD is a robust and reliable sample introduction method with ultra-fast analysis time (<15 s sample(-1)). Several oxidation and LDTD parameters were optimized to improve recoveries and signal intensity. MCs oxidation recovery yield was 103%, showing a complete reaction. Internal calibration with standard addition was achieved with the use of 4-phenylbutyric acid (4-PB) as internal standard and showed good linearity (R(2)>0.999). Limits of detection and quantification were 0.2 and 0.9 μg L(-1), respectively. These values are comparable with the WHO (World Health Organization) guideline of 1 μg L(-1) for total microcystin-LR congener in drinking water. Accuracy and interday/intraday variation coefficients were below 15%. Matrix effect was determined with a recovery of 91%, showing no significant signal suppression. This work demonstrates the use of the LDTD-APCI-MS/MS interface for the screening, detection and quantification of total MCs in complex environmental matrices.

  10. Determination of phosphodiesterase type V inhibitors in wastewater by direct injection followed by liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Causanilles, Ana; Emke, Erik; de Voogt, Pim

    2016-09-15

    A simple, fast and reliable analytical method for the determination of phosphodiesterase type V inhibitors in wastewater was developed and validated. The method was based on direct injection followed by liquid chromatography coupled to tandem mass spectrometry with triple quadrupole as mass analyzer. Transformation products and analogues were included in the target list besides the three active pharmaceutical ingredients (sildenafil, vardenafil and tadalafil). The method performance was thoroughly investigated, including the analyte stability in wastewater and matrix effect. All target compounds presented linear fits between their LOD and 500ng/L. The quantification limits ranged from 1.6 to 30ng/L for all compounds except for n-octylnortadalafil (LOQ: 100ng/L); precision calculated as intraday repeatability was lower than 30%; accuracy calculated as procedural recovery ranged successfully between 85 and 105% in all cases. The method was applied to samples collected during three week-long monitoring campaigns performed in 2013, 2014 and 2015 in three Dutch cities. Only sildenafil and its two metabolites, desmethyl- and desethylsildenafil, were present with normalized loads ranging from LOQ to 8.3, 11.8 and 21.6mg/day/1000 inh, respectively. Two additional week-long sets of samples were collected in Amsterdam at the time that a festival event took place, bringing around 350,000 visitors to the city. The difference in drug usage patterns was statistically studied: "weekday" versus "weekend", "normal" versus "atypical" week; and results discussed. The metabolite to parent drug concentration ratio evolution during consecutive years was discussed, leading to several possible explanations that should be further investigated. Finally, wastewater-based epidemiology approach was applied to back-calculate sildenafil consumption. PMID:27161135

  11. Sensitive and rapid liquid chromatography/tandem mass spectrometric assay for the quantification of piperaquine in human plasma.

    PubMed

    Singhal, Puran; Gaur, Ashwani; Gautam, Anirudh; Varshney, Brijesh; Paliwal, Jyoti; Batra, Vijay

    2007-11-01

    A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of piperaquine, an antimalarial drug, in human plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method involved a simple protein precipitation with methanol followed by rapid isocratic elution of analytes with 10mM ammonium acetate buffer/methanol/formic acid/ammonia solution (25/75/0.2/0.15, v/v) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and quantification by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 535.3-->288.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 1.0-250.2 ng/mL for piperaquine in plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) in plasma were 0.2 and 1.0 ng/mL, respectively. Acceptable precision and accuracy (+/-20% deviation for LLOQ standard and +/-15% deviation for other standards from the respective nominal concentration) were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully applied to analyze human plasma samples from phase-1 clinical studies. The mean pharmacokinetic parameters of piperaquine following 1000 mg oral dose: observed maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax) and elimination half-life (T1/2) were 46.1 ng/mL, 3.8h and 13 days, respectively. PMID:17923446

  12. Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry.

    PubMed

    Faqehi, Abdullah M M; Cobice, Diego F; Naredo, Gregorio; Mak, Tracy C S; Upreti, Rita; Gibb, Fraser W; Beckett, Geoffrey J; Walker, Brian R; Homer, Natalie Z M; Andrew, Ruth

    2016-05-01

    Estrogens circulate at concentrations less than 20pg/mL in men and postmenopausal women, presenting analytical challenges. Quantitation by immunoassay is unreliable at these low concentrations. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers greater specificity and sometimes greater sensitivity, but ionization of estrogens is inefficient. Introduction of charged moieties may enhance ionization, but many such derivatives of estrogens generate non-specific product ions originating from the "reagent" group. Therefore an approach generating derivatives with product ions specific to individual estrogens was sought. Estrogens were extracted from human plasma and serum using solid phase extraction and derivatized using 2-fluoro-1-methylpyridinium-p-toluenesulfonate (FMP-TS). Electrospray in positive mode with multiple reaction monitoring using a QTrap 5500 mass spectrometer was used to quantify "FMP" derivatives of estrogens, following LC separation. Transitions for the FMP derivatives of estrone (E1) and estradiol (E2) were compound specific (m/z 362→238 and m/z 364→128, respectively). The limits of detection and quantitation were 0.2pg on-column and the method was linear from 1-400pg/sample. Measures of intra- and inter-assay variability, precision and accuracy were acceptable (<20%). The derivatives were stable over 24h at 10°C (7-9% degradation). Using this approach, E1 and E2, respectively were detected in human plasma and serum: pre-menopausal female serum (0.5mL) 135-473, 193-722pmol/L; male plasma (1mL) 25-111, 60-180pmol/L and post-menopausal female plasma (2mL), 22-78, 29-50pmol/L. Thus FMP derivatization, in conjunction with LC-MS/MS, is suitable for quantitative analysis of estrogens in low abundance in plasma and serum, offering advantages in specificity over immunoassay and existing MS techniques.

  13. Simultaneous pharmacokinetic and pharmacodynamic analysis of 5α-reductase inhibitors and androgens by liquid chromatography tandem mass spectrometry.

    PubMed

    Upreti, Rita; Naredo, Gregorio; Faqehi, Abdullah M M; Hughes, Katherine A; Stewart, Laurence H; Walker, Brian R; Homer, Natalie Z M; Andrew, Ruth

    2015-01-01

    Benign prostatic hyperplasia and prostate cancer can be treated with the 5α-reductase inhibitors, finasteride and dutasteride, when pharmacodynamic biomarkers are useful in assessing response. A novel method was developed to measure the substrates and products of 5α-reductases (testosterone, 5α-dihydrotestosterone (DHT), androstenedione) and finasteride and dutasteride simultaneously by liquid chromatography tandem mass spectrometry, using an ABSciex QTRAP(®) 5500, with a Waters Acquity™ UPLC. Analytes were extracted from serum (500 µL) via solid-phase extraction (Oasis(®) HLB), with (13)C3-labelled androgens and d9-finasteride included as internal standards. Analytes were separated on a Kinetex C18 column (150 × 3 mm, 2.6 µm), using a gradient run of 19 min. Temporal resolution of analytes from naturally occurring isomers and mass +2 isotopomers was ensured. Protonated molecular ions were detected in atmospheric pressure chemical ionisation mode and source conditions optimised for DHT, the least abundant analyte. Multiple reaction monitoring was performed as follows: testosterone (m/z 289 → 97), DHT (m/z 291 → 255), androstenedione (m/z 287 → 97), dutasteride (m/z 529 → 461), finasteride (m/z 373 → 317). Validation parameters (intra- and inter-assay precision and accuracy, linearity, limits of quantitation) were within acceptable ranges and biological extracts were stable for 28 days. Finally the method was employed in men treated with finasteride or dutasteride; levels of DHT were lowered by both drugs and furthermore the substrate concentrations increased.

  14. Quantitation of bentysrepinine (Y101) in rat plasma by liquid chromatography tandem mass spectrometry: application to pharmacokinetic study.

    PubMed

    Fan, Huirong; Li, Ruixing; Gu, Yuan; Si, Duanyun; Liu, Changxiao

    2012-03-15

    A simple, accurate and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantitation of bentysrepinine (Y101) in rat plasma. After the addition of diphenhydramine (internal standard, IS), plasma samples were pretreated by protein precipitation. Chromatographic separation was carried out on an Atlantis(®) analytical column (4.6 mm × 100 mm, 5 μm, Waters) with methanol: 20 mM ammonium formate consisting of 1.0% formic acid (65:35, v/v) as the mobile phase at an isocratic flow rate of 0.4 mL/min for 7.5 min. The multiple reaction monitoring (MRM) transitions were performed at m/z 490.2→339.5 for Y101 and m/z 256.0→167.0 for IS on a SCIEX API 4000 mass spectrometer in the positive ion mode with electrospray ionization (ESI) source. Good linearity was achieved over the concentration range of 1-2500 ng/mL. The intra- and inter-day precisions were less than 8.3%, and the accuracy ranged from -4.0% to 2.8%. Y101 was stable during the analysis and the storage period. The pharmacokinetic profiles of Y101 at three dose levels were successfully studied for the first time in rats by this method. After single intra-gastric administration of Y101 at the doses of 25, 50 and 100 mg/kg, C(max) and AUC(0-t) were proportional to the doses given. PMID:22366283

  15. LipidBlast templates as flexible tools for creating new in-silico tandem mass spectral libraries.

    PubMed

    Kind, Tobias; Okazaki, Yozo; Saito, Kazuki; Fiehn, Oliver

    2014-11-18

    Tandem mass spectral libraries (MS/MS) are usually built by acquiring experimentally measured mass spectra from chemical reference compounds. We here show the versatility of in-silico or computer generated tandem mass spectra that are directly obtained from compound structures. We use the freely available LipidBlast development software to generate 15 000 MS/MS spectra of the glucuronosyldiacylglycerol (GlcADG) lipid class, recently discovered for the first time in plants. The generation of such an in-silico MS/MS library for positive and negative ionization mode took 5 h development time, including the validation of the obtained mass spectra. Such libraries allow for high-throughput annotations of previously unknown glycolipids. The publicly available LipidBlast templates are universally applicable for the development of MS/MS libraries for novel lipid classes.

  16. Ultra performance liquid chromatography tandem mass spectrometry assay for determination of kukoamine B in human blood and urine.

    PubMed

    Zhao, Qian; Li, Lili; Wang, Zhenlei; Jiang, Ji; Dong, Kai; Chen, Shuai; Hu, Pei

    2016-09-15

    In this paper, we report a sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method which is capable of quantifying kukoamine B (KB) levels in human blood and urine. Following solid phase extraction and direct dilution process, the analyte and its internal standard (D5-KB) run on an Acquity UPLC(®) HSS T3 column (2.1×50mm i.d., 1.8μm) by using a gradient elution method (run time was 1.5min). The mass spectrometric analysis was performed by using an API-5500 mass spectrometer coupled with an electro-spray ionization source. The MRM transitions of m/z 531.3(+)→222.1(+) and 536.3(+)→222.1(+) were used to quantify KB and D5-KB respectively. This assay method has been fully validated in terms of selectivity, linearity, lower limit of quantification, precision, accuracy, stability, recovery and matrix effect. The concentration range of this method is 10.0-2000.0ngmL(-1) in blood and 0.5-500.0ngmL(-1) in urine. Linearity (R(2)) of calibration curves were 0.9964±0.0022 and 0.9935±0.0053 for blood and urine, respectively (regression equation: y=ax+b). The precision (RSD%) of quality control samples is less than 10.3% for blood and less than 10.5% for urine. The accuracy (RE%) is within -4.0-11.3% and -11.7-12.5% for blood and urine respectively. KB was stable after 4h in ice-water bath, 1 freeze/thaw cycles and 180days at -80°C for blood samples; and was stable after 3h at room temperature, 3 freeze/thaw cycles and 180days at -80°C for urine samples. Recoveries of KB were 4.7±0.9% in blood and 96.5±1.3% in urine, respectively. Additionally, the applicability of this method has been proved by analyzing clinical samples from pharmacokinetic study of KB in human. PMID:27447928

  17. A universal SI-traceable isotope dilution mass spectrometry method for protein quantitation in a matrix by tandem mass tag technology.

    PubMed

    Li, Jiale; Wu, Liqing; Jin, Youxun; Su, Ping; Yang, Bin; Yang, Yi

    2016-05-01

    Isotope dilution mass spectrometry (IDMS), an important metrological method, is widely used for absolute quantification of peptides and proteins. IDMS employs an isotope-labeled peptide or protein as an internal standard although the use of a protein provides improved accuracy. Generally, the isotope-labeled protein is obtained by stable isotope labeling by amino acids in cell culture (SILAC) technology. However, SILAC is expensive, laborious, and time-consuming. To overcome these drawbacks, a novel universal SI-traceable IDMS method for absolute quantification of proteins in a matrix is described with human transferrin (hTRF). The hTRF and a human serum sample were labeled with different tandem mass tags (TMTs). After mixing the TMT-labeled hTRF and serum sample together followed by digestion, the peptides were separated by nano-liquid chromatography and analyzed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Using the signature peptides, we calculated the ratios of reporter ions from the TMT-labeled peptides which, in turn, allowed determination of the mass fraction of hTRF. The recovery ranged from 97% to 105% with a CV of 3.9%. The LOD and LOQ were 1.71 × 10(-5) g/g and 5.69 × 10(-5) g/g of hTRF in human serum, respectively, and the relative expanded uncertainty was 4.7% with a mass fraction of 2.08 mg/g. For comparison, an enzyme-linked immunosorbent assay (ELISA) method for hTRF yielded a mass fraction of 2.03 mg/g. This method provides a starting point for establishing IDMS technology to accurately determine the mass fractions of protein biomarkers in a matrix with traceability to SI units. This technology should support the development of a metrological method useful for quantification of a wide variety of proteins. PMID:26942737

  18. Tandem mass spectral libraries of peptides in digests of individual proteins: Human Serum Albumin (HSA).

    PubMed

    Dong, Qian; Yan, Xinjian; Kilpatrick, Lisa E; Liang, Yuxue; Mirokhin, Yuri A; Roth, Jeri S; Rudnick, Paul A; Stein, Stephen E

    2014-09-01

    This work presents a method for creating a mass spectral library containing tandem spectra of identifiable peptide ions in the tryptic digestion of a single protein. Human serum albumin (HSA(1)) was selected for this purpose owing to its ubiquity, high level of characterization and availability of digest data. The underlying experimental data consisted of ∼3000 one-dimensional LC-ESI-MS/MS runs with ion-trap fragmentation. In order to generate a wide range of peptides, studies covered a broad set of instrument and digestion conditions using multiple sources of HSA and trypsin. Computer methods were developed to enable the reliable identification and reference spectrum extraction of all peptide ions identifiable by current sequence search methods. This process made use of both MS2 (tandem) spectra and MS1 (electrospray) data. Identified spectra were generated for 2918 different peptide ions, using a variety of manually-validated filters to ensure spectrum quality and identification reliability. The resulting library was composed of 10% conventional tryptic and 29% semitryptic peptide ions, along with 42% tryptic peptide ions with known or unknown modifications, which included both analytical artifacts and post-translational modifications (PTMs) present in the original HSA. The remaining 19% contained unexpected missed-cleavages or were under/over alkylated. The methods described can be extended to create equivalent spectral libraries for any target protein. Such libraries have a number of applications in addition to their known advantages of speed and sensitivity, including the ready re-identification of known PTMs, rejection of artifact spectra and a means of assessing sample and digestion quality.

  19. Planetary In Situ Sample Analysis with Tandem Two-Step Laser Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Brinckerhoff, W. B.; Getty, S. A.; Cornish, T. J.; Ecelberger, S. A.; Li, X.; Merrill Floyd, M. A.; Arevalo, R.; Elsila, J.; Callahan, M. P.

    2012-12-01

    -) and organic moieties. Second, by focusing a separate "post-ionization" laser pulse just above the sample surface, we can achieve two-step laser mass spectrometry, or L2MS, in the same highly-miniaturized TOF-MS. L2MS enables selective analysis of aromatic organics even in the presence of a complex mineral matrix. Finally, by introducing an ion optical gate in the flight path, we are able to take advantage of the broad focusing capabilities of the "curved field" reflectron at the core of the TOF-MS to achieve pseudo-tandem structural analysis of selected organics. The high-speed gate is used to admit only the molecular ion/s of interest into the reflectron. Diagnostic fragments of the ion/s obtained through metastable decay or active collision-induced dissociation (CID) remain in focus despite having widely variable velocities and masses. As such even molecular isomers with differing fragmentation pathways may be distinguished through a series of pseudo-tandem mass spectra that could be obtained in an automatic process during a mission. The "real-world" benefits of these enhancements are being fully characterized using a set of synthetic and natural standard samples as well as several planetary analogs and meteorites.

  20. Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lu, Shijun; Tran, Buu N; Nelsen, Jamie L; Aldous, Kenneth M

    2009-08-15

    Mitragynine is the primary active alkaloid extracted from the leaves of Mitragyna speciosa Korth, a plant that originates in South-East Asia and is commonly known as kratom in Thailand. Kratom has been used for many centuries for their medicinal and psychoactive qualities, which are comparable to that of opiate-based drugs. Kratom abuse can lead to a detectable content of mitragynine residue in urine. Ultra trace amount of mitragynine in human urine was determined by a high performance liquid chromatography coupled to an electrospray tandem mass spectrometry (HPLC-ESI/MS/MS). Mitragynine was extracted by methyl t-butyl ether (MTBE) and separated on a HILIC column. The ESI/MS/MS was accomplished using a triple quadrupole mass spectrometer in positive ion detection and multiple reactions monitoring (MRM) mode. Ajmalicine, a mitragynine's structure analog was selected as internal standard (IS) for method development. Quality control (QC) performed at three levels 0.1, 1 and 5 ng/ml of mitragynine in urine gave mean recoveries of 90, 109, and 98% with average relative standard deviation of 22, 12 and 16%, respectively. The regression linearity of mitragynine calibration ranged from 0.01 to 5.0 ng/ml was achieved with correlation coefficient greater than 0.995. A detection limit of 0.02 ng/ml and high precision data within-day and between days analysis were obtained. PMID:19577523

  1. [Determination of endogenous steroids in urine by liquid chromatography-tandem mass spectromretry].

    PubMed

    Wang, Mengye; Xiang, Ping; Yan, Hui; Shen, Baohua; Shen, Min

    2008-01-01

    A method was developed for the determination of endogenous steroids in urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with methyltestosterone as internal standard. After enzymatic hydrolysis by beta-glucuronidase and liquid-liquid extraction, the urine sample was chromatographed on a Cosmosil C18 column with a mixture of methanol and ammonium acetate-formic acid (68:32, v/v) as mobile phase, then detected using MS/MS system with electrospray ionization (ESI) in multi-reaction monitoring (MRM) mode. The detection limits ranged from 0.01 ng/mL to 10 ng/mL. The recoveries ranged from 96.7% to 106.5%, and the intra- and inter-day precisions (measured as relative standard deviations) were less than 7% and 11%, respectively. With simple and fast sample preparation, the method was sensitive and specific for simultaneous determination of these 5 kinds of endogenous steroids in urine. The method has been successfully applied in pharmacokinetic study and is thus a potential alternative for gas chromatography-mass spectrometry (GC-MS) based procedures in routine analysis of endogenous steroids such as DHEA in human urine.

  2. Simultaneous determination of eight illegal dyes in chili products by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Juan; Ding, Xiao-Ming; Liu, Dan-Dan; Guo, Fei; Chen, Yu; Zhang, Yan-Bing; Liu, Hong-Min

    2013-12-30

    A sensitive and accurate method based on the use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the simultaneous determination of eight illegal synthetic dyes (Sudan (I-IV), Para Red, Rhodamine B, Chrysoidin and Auramine O) in chili products. A simple sample treatment procedure entailing the use of an extraction step with acetonitrile/H2O (9/1) without further cleanup was developed. HPLC was performed on a C18 column using a multistep gradient elution with 5mM ammonium acetate (pH 3.0 with formic acid) and methanol as the mobile phase. Mass spectral acquisition was done in multiple reaction monitoring (MRM) mode using positive electrospray ionization (ESI). Linear calibrations were obtained with correlation coefficients R(2)>0.99. Limit of detection (LOD) and limit of quantification (LOQ) for the studied dyes were in the ranges of 0.05-0.6μgkg(-1) and 0.3-3.0μgkg(-1) depending on matrices, respectively. The recoveries of the eight synthetic dyes in five matrices ranged from 70.5% to 119.2%. The intra- and inter-day precisions (RSDs) were between 2.3-15.8% and 5.7-15.6%, respectively. The applicability of the method to the determination of eight banned dyes in chili products was demonstrated. PMID:24212142

  3. Quantitative analysis of clenbuterol in meat products using liquid chromatography-electrospray ionisation tandem mass spectrometry.

    PubMed

    Guy, P A; Savoy, M C; Stadler, R H

    1999-12-24

    A method is presented that allows quantitation of clenbuterol in meat and liver products at the ng/kg level by liquid chromatography-electrospray ionisation tandem mass spectrometry (LC-ESIMS-MS) using a stable isotopically labeled internal standard. The practical procedure involves acid extraction followed by two solid-phase clean-up steps with C18 and strong cation-exchange (SCX) resins. The typical recovery of the analyte spiked at 0.4 microg/kg in meat and liver samples was at 63+/-7%. Mass spectral acquisition was done in multiple reaction monitoring (MRM) to provide a high degree of sensitivity, achieving a limit of detection and quantitation at 10 and 15 ng/kg, respectively. Two precursor ions at m/z 277 and 279, corresponding to the characteristic isotopic cluster of the two chlorine atoms of clenbuterol, were monitored by LC-ESIMS-MS to provide unambiguous identity of the analyte. Samples of meat and liver of various origins with either incurred residues or spiked with known amounts of clenbuterol were used to validate the method.

  4. Quantitation of Parathyroid Hormone in Serum or Plasma by Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Ketha, Hemamalini; Singh, Ravinder J

    2016-01-01

    Parathyroid hormone (PTH), an 84 amino acid peptide hormone, is an important regulator of calcium homeostasis. Quantitation of PTH in serum is useful for the diagnosis of primary hyperparathyroidism, hypoparathyroidism, and for monitoring osteodystrophy in patients with renal failure. The biological activity of PTH arises from binding of PTH (N terminus) to its target receptor (D'Amour et al., Kidney Int 68: 998-1007, 2005). Several C-terminal and N-terminal fragments circulate in normal subjects. Recent studies have demonstrated that accurate quantitation of PTH fragments may be of clinical value. In this chapter a mass spectrometry based method for quantitation of PTH(1-84) is described. This method involves immunoaffinity capture of PTH followed by trypsinization and quantitation of PTH-specific tryptic peptides by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The N-terminal tryptic peptide, PTH(1-13) as surrogate of 1-84 PTH, is used for quantitation. PMID:26602132

  5. Support Vector Machines for Improved Peptide Identification from Tandem Mass Spectrometry Database Search

    SciTech Connect

    Webb-Robertson, Bobbie-Jo M.

    2009-05-06

    Accurate identification of peptides is a current challenge in mass spectrometry (MS) based proteomics. The standard approach uses a search routine to compare tandem mass spectra to a database of peptides associated with the target organism. These database search routines yield multiple metrics associated with the quality of the mapping of the experimental spectrum to the theoretical spectrum of a peptide. The structure of these results make separating correct from false identifications difficult and has created a false identification problem. Statistical confidence scores are an approach to battle this false positive problem that has led to significant improvements in peptide identification. We have shown that machine learning, specifically support vector machine (SVM), is an effective approach to separating true peptide identifications from false ones. The SVM-based peptide statistical scoring method transforms a peptide into a vector representation based on database search metrics to train and validate the SVM. In practice, following the database search routine, a peptides is denoted in its vector representation and the SVM generates a single statistical score that is then used to classify presence or absence in the sample

  6. Analysis of aristolochic acids, aristololactams and their analogues using liquid chromatography tandem mass spectrometry.

    PubMed

    Yu, Jie; Ma, Chao-Mei; Wang, Xuan; Shang, Ming-Ying; Hattori, Masao; Xu, Feng; Jing, Yu; Dong, Shi-Wen; Xu, Yu-Qiong; Zhang, Cui-Ying; Cai, Shao-Qing

    2016-08-01

    More than 80 aristolochic acids (AAs) and aristololactams (ALs) have been found in plants of the Aristolochiaceae family, but relatively few have been fully studied. The present study aimed at developing and validating a liquid chromatography tandem mass spectrometry (LC/MS(n)) for the analysis of these compounds. We characterized the fragmentation behaviors of 31 AAs, ALs, and their analogues via high performance liquid chromatography coupled with electrospray ionization mass spectrometry. We summarized their fragmentation rules and used these rules to identify the constituents contained in Aristolochia contorta, Ar. debilis, Ar. manshurensis, Ar. fangchi, Ar. cinnabarina, and Ar. mollissima. The AAs and ALs showed very different MS behaviors. In MS(1) of AAs, the characteristic pseudomolecular ions were [M + NH4](+), [M + H](+), and [M + H - H2O](+). However, only [M + H](+) was found in the MS(1) of ALs, which was simpler than that of AAs. Distinct MS(n)fragmentation patterns were found for AAs and ALs, showing the same skeleton among the different substituent groups. The distribution of the 31 constituents in the 6 species of Aristolochia genus was reported for the first time. 25 Analogues of AAs and ALs were detected in this genus. A hierarchical schemes and a calculating formula of the molecular formula of these nitrophenanthrene carboxylic acids and their lactams were proposed. In conclusion, this method could be applied to identification of similar unknown constituents in other plants. PMID:27608953

  7. Determination of ten sulphonamides in egg by liquid chromatography-tandem mass spectrometry.

    PubMed

    Forti, A F; Scortichini, G

    2009-04-01

    A precise and reliable method for the determination of 10 sulphonamide antibiotics (sulfadiazine, sulfathiazole, sulfamerazine, sulfamethazine, sulfamethoxypyridazine, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadimethoxine and sulfaquinoxaline) in egg by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. Drugs were extracted using a mixture of dichloromethane/acetone (50:50, v/v), acidified with acetic acid and then cleaned-up on a cation-exchange solid-phase extraction (SPE) cartridge. The chromatographic separation was performed by gradient on a C(18) column with a mobile phase of methanol-water containing 0.1% formic acid and 5mM ammonium acetate, then sulphonamides were detected in a triple-quadrupole mass spectrometer operated in positive electrospray ionization mode (ESI(+)). The method was validated at 15, 30 and 45 microgkg(-1). These levels were much lower than the corresponding maximum residue limit of 100 microgkg(-1) set for sulphonamides in several matrices but not in eggs, where the presence of such residues is not permitted. Results were quantitated against the selected internal standard (13)C(6)-sulphamethazine and also according to the matrix-matched approach. The within-laboratory reproducibility, expressed as a relative standard deviation, never exceeded 21%. All decision limit (CCalpha) values lied in the range between 16.1 and 20.5 microgkg(-1) and the corresponding results for detection capability (CCbeta) were 16.9 and 25.7 microgkg(-1). Ruggedness was estimated according to the Youden robustness test. PMID:19286032

  8. Determination of doxepin and desmethyldoxepin in human plasma using liquid chromatography-tandem mass spectrometry.

    PubMed

    Badenhorst, D; Sutherland, F C; de Jager, A D; Scanes, T; Hundt, H K; Swart, K J; Hundt, A F

    2000-05-26

    A sensitive method for the simultaneous determination of doxepin and its active metabolite desmethyldoxepin in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane-isoamyl alcohol, separated on a Phenomenex Luna C18 5 microm, 150x2.1 mm column with a mobile phase consisting of methanol-water-formic acid (600:400:0.5, v/v) at a flow-rate of 0.25 ml/min. Detection was achieved by a Perkin-Elmer API 2000 mass spectrometer at unit resolution in multiple reaction monitoring mode monitoring the transition of the protonated molecular ions m/z 280.2, 266.2 and 250.1 to the product ions m/z 107.1, 107.1 and 191.0 for analyte, metabolite and internal standard (benzoctamine-HCl), respectively. TurbolonSpray ionisation was used for ion production. The mean recovery for doxepin and desmethyldoxepin was 90% and 75%, respectively, with a lower limit of quantification at 0.320 ng/ml and 0.178 ng/ml for the analyte and its metabolite, respectively, using 0.5 ml plasma for extraction. This is the first assay method described for the simultaneous determination of doxepin and desmethyldoxepin in plasma using LC-MS-MS. The method is sensitive enough to be used in drug bioavailability studies with doxepin.

  9. Poiseuille flow-induced vibrations of two tandem circular cylinders with different mass ratios

    NASA Astrophysics Data System (ADS)

    Jiang, Ren-Jie; Lin, Jian-Zhong

    2016-06-01

    Flow-induced vibrations of two tandem circular cylinders with different mass ratios confined between two parallel walls are numerically studied via a lattice Boltzmann method. With fixed Reynolds number Re = 100 and blockage ratio β = 1/4, the effects of mass ratio m* = [0.0625, 16] and streamwise separation between two cylinders S/D = [1.125, 10] on the cylinder motions and vortex wake modes are investigated. A variety of distinct cylinder motion regimes involving the symmetric periodic vibration, biased quasi-periodic vibration, beating vibration, and steady regimes, with the corresponding wake structures, e.g., two rows of alternately rotating vortices, a single row of same-sign vortices, and steady wake, are observed. For each current case, the cylinder motion type is exclusive and in the binary oscillation regime, both cylinders always vibrate at a common primary frequency. The lighter cylinder usually oscillates at a larger amplitude than the heavier one, while the heavier cylinder undergoes larger lift force than the lighter one. The lift force and cylinder displacement always behave as an out-of-phase state. In the gap-interference region, large-amplitude oscillations could be produced extensively and in the wake-interference region, the cylinder motions and fluid flows are mainly dependent on the upstream cylinder. When the separation is large enough, both cylinders behave as two isolated ones. The mechanisms for the excitations of cylinder vibrations have also been analysed.

  10. De novo sequencing of peptides from top-down tandem mass spectra

    SciTech Connect

    Vyatkina, Kira; Wu, Si; Dekker, Leendert J.; vanDuijn, Martijn M.; Liu, Xiaowen; Tolic, Nikola; Dvorkin, Mikhail; Alexandrova, Sonya; Luider, Theo N.; Pasa-Tolic, Ljiljana; Pevzner, Pavel A.

    2015-09-28

    De novo sequencing of proteins and peptides is one of the most important problems in mass spectrometry-driven proteomics. A variety of methods have been developed to accomplish this task from a set of bottom-up tandem (MS/MS) mass spectra. However, a more recently emerged top-down technology, now gaining more and more popularity, opens new perspectives for protein analysis and characterization, implying a need in efficient algorithms for processing this kind of MS/MS data. Here we describe a method that allows to retrieve from a set of top-down MS/MS spectra long and accurate sequence fragments of the proteins contained in a sample. To this end, we outline a strategy for generating high-quality sequence tags from top-down spectra, and introduce the concept of a T-Bruijn graph by adapting to the case of tags the notion of an A-Bruijn graph widely used in genomics. The output of the proposed approach represents the set of amino acid strings spelled out by optimal paths in the connected components of a T-Bruijn graph. We illustrate its performance on top-down datasets acquired from carbonic anhydrase 2 (CAH2) and the Fab region of alemtuzumab.

  11. The inclusion of ADA-SCID in expanded newborn screening by tandem mass spectrometry.

    PubMed

    la Marca, Giancarlo; Giocaliere, Elisa; Malvagia, Sabrina; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria Luisa; Canessa, Clementina; Lippi, Francesca; Romano, Francesca; Guerrini, Renzo; Resti, Massimo; Azzari, Chiara

    2014-01-01

    Severe combined immunodeficiency due to adenosine-deaminase defect (ADA-SCID) is usually deadly in childhood because of severe recurrent infections. When clinical diagnosis is done, permanent damages due to infections or metabolite accumulation are often present. Gene therapy, bone marrow transplantation or enzyme replacement therapy may be effective if started early. The aim of this study was to set-up a robust method suitable for screening with a minimized preparation process and with inexpensive running costs, for diagnosing ADA-SCID by tandem mass spectrometry. ADA-SCID satisfies all the criteria for inclusion in a newborn screening program. We describe a protocol revised to incorporate adenosine and 2-deoxyadenosine testing into an expanded newborn screening program. We assessed the effectiveness of this approach testing dried blood spots from 4 genetically confirmed early-onset and 5 delayed-onset ADA-SCID patients. Reference values were established on 50,000 healthy newborns (deoxyadenosine <0.09μmol/L, adenosine <1.61μmol/L). We also developed a second tier test to distinguish true positives from false positives and improve the positive predictive value of an initial abnormal result. In the first 18 months, the pilot project has identified a newborn with a genetically confirmed defect in adenosine deaminase (ADA) gene. The results show that the method having great simplicity, low cost and low process preparations can be fully applicable to a mass screening program.

  12. Statistical model for large-scale peptide identification in databases from tandem mass spectra using SEQUEST.

    PubMed

    López-Ferrer, Daniel; Martínez-Bartolomé, Salvador; Villar, Margarita; Campillos, Mónica; Martín-Maroto, Fernando; Vázquez, Jesús

    2004-12-01

    Recent technological advances have made multidimensional peptide separation techniques coupled with tandem mass spectrometry the method of choice for high-throughput identification of proteins. Due to these advances, the development of software tools for large-scale, fully automated, unambiguous peptide identification is highly necessary. In this work, we have used as a model the nuclear proteome from Jurkat cells and present a processing algorithm that allows accurate predictions of random matching distributions, based on the two SEQUEST scores Xcorr and DeltaCn. Our method permits a very simple and precise calculation of the probabilities associated with individual peptide assignments, as well as of the false discovery rate among the peptides identified in any experiment. A further mathematical analysis demonstrates that the score distributions are highly dependent on database size and precursor mass window and suggests that the probability associated with SEQUEST scores depends on the number of candidate peptide sequences available for the search. Our results highlight the importance of adjusting the filtering criteria to discriminate between correct and incorrect peptide sequences according to the circumstances of each particular experiment.

  13. Screening of anabolic steroids in horse urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Yu, Nola H; Ho, Emmie N M; Leung, David K K; Wan, Terence S M

    2005-04-29

    Anabolic steroids have the capability of improving athletic performance and are banned substances in the Olympic games as well as in horseracing and equestrian competitions. The control of their abuse in racehorses is traditionally performed by detecting the presence of anabolic steroids and/or their metabolite(s) in urine samples using gas chromatography-mass spectrometry (GC-MS). However, this approach usually requires tedious sample processing and chemical derivatisation steps and could be very insensitive in detecting certain steroids. This paper describes a high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method for the detection of anabolic steroids that are poorly covered by GC-MS. Enzyme-treated urine was processed by solid-phase extraction (SPE) using a Bond Elut Certify cartridge, followed by a base wash for further cleanup. Separation of the steroids was carried out on a reversed-phase DB-8 column using 0.1% acetic acid and methanol as the mobile phase in a gradient elution programme. The mass spectrometer for the detection of the steroids was operated in the positive electrospray ionisation (ESI) mode with multiple reaction monitoring (MRM). Urine samples fortified with 15 anabolic steroids (namely, androstadienone, 1-androstenedione, bolasterone, boldione, 4-estrenedione, gestrinone, methandrostenolone, methenolone, 17alpha-methyltestosterone, norbolethone, normethandrolone, oxandrolone, stenbolone, trenbolone and turinabol) at low ng/mL levels were consistently detected. No significant matrix interference was observed at the retention times of the targeted ion masses in blank urine samples. The method specificity, sensitivity, precision, recoveries, and the performance of the enzyme hydrolysis step were evaluated. The successful application of the method to analyse methenolone acetate administration urine samples demonstrated that the method could be effective in detecting anabolic steroids and their metabolites in horse

  14. Tandem time-of-flight mass spectrometer for cluster--surface scattering experiments

    SciTech Connect

    Beck, R.D.; Weis, P.; Braeuchle, G.; Rockenberger, J.

    1995-08-01

    A new tandem time-of-flight mass spectrometer is described which is designed to study the mass-, velocity-, and angle-resolved scattering of cluster ions from solid surfaces. Clusters are produced in a supersonic jet laser desorption/vaporization source, ionized either directly in the formation step or by subsequent photoionization of neutrals, mass selected in a primary time-of-flight region, and decelerated to the impact energy (50--1000 eV) close to the target surface. Cluster--surface collisions take place in a field-free region in order to determine both velocity and angular distributions of the scattered clusters and fragments with an independently pulsed, rotatable secondary time-of-flight mass spectrometer. Several surface targets can be mounted in the UHV scattering chamber (10{sup {minus}10} Torr base pressure) on a five-axis manipulator which, together with the rotatable secondary TOF, allows for independent variation of incident and scattering angles. Target surfaces can be cleaned by direct current heating and sputtering with an argon-ion gun. Surface structure and composition are assessed by low-energy electron diffraction (LEED) and Auger spectroscopy with a four grid reverse view LEED/Auger system. Surface collision experiments of fullerenes (C{sup +}{sub 60}, C{sup +}{sub 70}, C{sup +}{sub 76}, C{sup +}{sub 84}, ...) and metallofullerenes (La{at}C{sup +}{sub 82}) with highly oriented pyrolitic graphite (HOPG) surfaces are described as examples for the performance of the instrument. Effects of surface contamination in the scattering of fullerenes from HOPG are described to demonstrate the need for thorough cleaning procedures in order to obtain reproducible results. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  15. Preclinical pharmacokinetic evaluation of a new formulation of a bifendate solid dispersion using a supercritical fluid chromatography-tandem mass spectrometry method.

    PubMed

    Liu, Muhua; Zhao, Longshan; Yang, Dan; Ma, Jin; Wang, Xianglin; Zhang, Tianhong

    2014-11-01

    In order to evaluate the pharmacokinetic characteristics of a new formulation of a bifendate solid dispersion in beagle dogs, a novel, sensitive and rapid supercritical fluid chromatography-tandem mass spectrometry (SFC-MS/MS) method was established and validated. Plasma samples were subjected to liquid-liquid extraction with ethyl acetate. Separation of bifendate and diazepam (internal standard, IS) was performed on an HSS C18 SB column (3×100mm, 1.8μm) with a mobile phase consisting of CO2 (≥99.99%) - methanol (95:5, v/v) at a flow rate of 2mL/min and the compensation solvent was methanol with 2% formic acid at a flow rate of 0.2mL/min. A tandem triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) mode with an electrospray ionization (ESI) source. Quantification of the ion transitions was at m/z 419.2→387.0 and 284.5→193.2 for bifendate and IS, respectively. The method was sensitive with a lower limit of quantification (LLOQ) of 0.5ng/mL and linear over the concentration range 0.5-250ng/mL. All the validation data, such as precision, accuracy, extraction recovery and matrix effect, were all within acceptable criteria. The method has been successfully applied to a pharmacokinetic study of bifendate in beagle dogs after oral administration of a bifendate solid dispersion.

  16. Microfluidic chip based nano liquid chromatography coupled to tandem mass spectrometry for the determination of abused drugs and metabolites in human hair.

    PubMed

    Zhu, Kevin Y; Leung, K Wing; Ting, Annie K L; Wong, Zack C F; Ng, Winki Y Y; Choi, Roy C Y; Dong, Tina T X; Wang, Tiejie; Lau, David T W; Tsim, Karl W K

    2012-03-01

    A microfluidic chip based nano-HPLC coupled to tandem mass spectrometry (nano-HPLC-Chip-MS/MS) has been developed for simultaneous measurement of abused drugs and metabolites: cocaine, benzoylecgonine, cocaethylene, norcocaine, morphine, codeine, 6-acetylmorphine, phencyclidine, amphetamine, methamphetamine, MDMA, MDA, MDEA, and methadone in the hair of drug abusers. The microfluidic chip was fabricated by laminating polyimide films and it integrated an enrichment column, an analytical column and a nanospray tip. Drugs were extracted from hairs by sonication, and the chromatographic separation was achieved in 15 min. The drug identification and quantification criteria were fulfilled by the triple quardropule tandem mass spectrometry. The linear regression analysis was calibrated by deuterated internal standards with all of the R(2) at least over 0.993. The limit of detection (LOD) and the limit of quantification (LOQ) were from 0.1 to 0.75 and 0.2 to 1.25 pg/mg, respectively. The validation parameters including selectivity, accuracy, precision, stability, and matrix effect were also evaluated here. In conclusion, the developed sample preparation method coupled with the nano-HPLC-Chip-MS/MS method was able to reveal the presence of drugs in hairs from the drug abusers, with the enhanced sensitivity, compared with the conventional HPLC-MS/MS. PMID:22281681

  17. Rapid simultaneous analysis of 17 haloacetic acids and related halogenated water contaminants by high-performance ion chromatography-tandem mass spectrometry.

    PubMed

    Xue, Runmiao; Donovan, Ariel; Shi, Honglan; Yang, John; Hua, Bin; Inniss, Enos; Eichholz, Todd

    2016-09-01

    Haloacetic acids (HAAs), which include chloroacetic acids, bromoacetic acids, and emerging iodoacetic acids, are toxic water disinfection byproducts. General screening methodology is lacking for simultaneously monitoring chloro-, bromo-, and iodoacetic acids. In this study, a rapid and sensitive high-performance ion chromatography-tandem mass spectrometry method for simultaneous determination of chloro-, bromo-, and iodo- acetic acids and related halogenated contaminants including bromate, bromide, iodate, and iodide was developed to directly analyze water samples after filtration, eliminating the need for preconcentration, and chemical derivatization. The resulting method was validated in both untreated and treated water matrices including tap water, bottled water, swimming pool water, and both source water and drinking water from a drinking water treatment facility to demonstrate application potential. Satisfactory accuracies and precisions were obtained for all types of tested samples. The detection limits of this newly developed method were lower or comparable with similar techniques without the need for extensive sample treatment requirement and it includes all HAAs and other halogenated compounds. This provides a powerful methodology to water facilities for routine water quality monitoring and related water research, especially for the emerging iodoacetic acids. Graphical abstract High performance ion chromatography-tandem mass spectrometry method for detection of haloacetic acids in water.

  18. A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology.

    PubMed

    Bunch, Dustin R; Heideloff, Courtney; Ritchie, James C; Wang, Sihe

    2010-12-01

    Busulfan is used in myeloablative preparation regimens for hematopoietic bone marrow transplantation. Due to its narrow therapeutic range therapeutic drug monitoring of busulfan is recommended. In this study a fast and simple method for measuring busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed utilizing turbulent flow online extraction technology. Serum or plasma was mixed with acetonitrile containing d(8)-busulfan. After centrifugation the supernatant was injected onto a turbulent flow preparatory column then transferred to a C18 analytical column monitored by a tandem mass spectrometer set at positive electrospray ionization. The analytical cycle time was 4.0min. The method was linear from 0.15 to 41.90μmol/L with an accuracy of 87.9-103.0%. Inter- and intra-assay CVs across four concentration levels were 2.1-7.8%. No significant carryover or ion suppression was observed. No interference was observed from commercial control materials containing more than 100 compounds. Comparison with a well established LC-MS/MS method using patient specimens (n=45) showed a mean bias 1.3% with Deming regression of slope 1.02, intercept -0.02μmol/L, and a linear correlation coefficient 0.9883. The LC-MS/MS method coupled with turbulent flow online sample cleaning technology described here offers reliable busulfan quantitation in serum or plasma with minimum manual sample preparation and was fully validated for clinical use.

  19. Sensitive liquid chromatography-tandem mass spectrometry method for the determination of cefixime in human plasma: application to a pharmacokinetic study.

    PubMed

    Meng, Fang; Chen, Xiaoyan; Zeng, Yalin; Zhong, Dafang

    2005-05-25

    A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed to determine cefixime ((6R,7R)-7-[(Z)-2-(2-amino-4-thiazolyl)-2-(carboxymethoxyimino)acetamido]-8-oxo-3-vinyl-5-thia-1-azabicyclo-[4,2,0]-oct-2-ene-2-carboxylic acid) in human plasma. After a simple protein precipitation using acetonitrile, the post-treatment samples were analyzed on a C(8) column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water-formic acid (40:60:0.5, v/v/v). The analyte and internal standard cefetamet were both detected by use of selected reaction monitoring mode. The method was linear in the concentration range of 0.05-8.0 microg/ml. The lower limit of quantification was 0.05 microg/ml. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 12.7%. The accuracy determined at three concentrations (0.05, 0.80 and 7.2 microg/ml for cefixime) was within +/-2.0% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method herein described was successfully applied for the evaluation of pharmacokinetic profiles of cefixime capsule in 24 healthy volunteers.

  20. Ultrapressure liquid chromatography-tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for quantification of 4-methoxydiphenylmethane in pharmacokinetic evaluation.

    PubMed

    Farhan, Nashid; Fitzpatrick, Sean; Shim, Yun M; Paige, Mikell; Chow, Diana Shu-Lian

    2016-09-01

    4-Methoxydiphenylmethane (4-MDM), a selective augmenter of Leukotriene A4 Hydrolase (LTA4H), is a new anti-inflammatory compound for potential treatment of chronic obstructive pulmonary disease (COPD). Currently, there is no liquid chromatography tandem mass spectrometric (LC-MS/MS) method for the quantification of 4-MDM. A major barrier for developing the LC-MS/MS method is the inability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to ionize 4-MDM due to its hydrophobicity and lack of any functional group for ionization. With the advent of atmospheric pressure photoionization (APPI) technique, many hydrophobic compounds have been demonstrated to ionize by charge transfer reactions. In this study, a highly sensitive ultrapressure liquid chromatography tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for the quantifications of 4-MDM in rat plasma has been developed and validated. 4-MDM was extracted from the plasma by solid phase extraction (SPE) and separated chromatographically using a reverse phase C8 column. The photoionization (PI) was achieved by introducing anisole as a dopant to promote the reaction of charge transfer. The assay with a linear range of 5 (LLOQ)-400ngmL(-1) met the regulatory requirements for accuracy, precision and stability. The validated assay was employed to quantify the plasma concentrations of 4-MDM after an oral dosing in Sprague Dawley (SD) rats.

  1. Simultaneous quantification of two canthinone alkaloids of Picrasma quassioides in rat plasma by liquid chromatography-tandem mass spectrometry and its application to a rat pharmacokinetic study.

    PubMed

    Shi, Yuanyuan; Hong, Chunyan; Xu, Jian; Yang, Xiaoling; Xie, Ning; Feng, Feng; Liu, Wenyuan

    2015-04-01

    Picrasma quassioides (D. Don) Benn. is used in traditional Chinese medicine for the treatment of inflammation. Characteristic components of the medicinal extract are canthinone alkaloids. In this study, a sensitive and rapid liquid chromatography with tandem mass spectrometry method has been developed for simultaneous quantification of two major canthinone alkaloids, 5-hydroxy-4-methoxycanthin-6-one and 4,5-dimethoxycanthin-6-one, in rat plasma after oral administration of P. quassioides extract (200 mg/kg). The chromatographic separation was performed on a C18 column using acetonitrile-aqueous 0.1% formic acid (90:10, v/v) as the mobile phase. Plasma samples were prepared for analysis using a simple liquid-liquid extraction with ethyl acetate. Analytes were detected using tandem mass spectrometry in positive multiple reaction monitoring mode. Method validation revealed excellent linearity over the range 1.25-900 ng/mL for 5-hydroxy-4-methoxycanthin-6-one and 0.5-800 ng/mL for 4,5-dimethoxycanthin-6-one with satisfactory intra- and inter-day precision, accuracy and recovery. Samples were stable under the conditions tested. The pharmacokinetic profiles of the analytes in rats showed that both canthinones were rapidly absorbed and that 4,5-dimethoxycanthin-6-one was eliminated faster than 5-hydroxy-4-methoxycanthin-6-one.

  2. Simultaneous quantification of cryptotanshinone and its active metabolite tanshinone IIA in plasma by liquid chromatography/tandem mass spectrometry (LC-MS/MS).

    PubMed

    Hao, Haiping; Wang, Guangji; Li, Peng; Li, Jing; Ding, Zuoqi

    2006-02-13

    A rapid and sensitive method for the simultaneous determination of cryptotanshinone and its active metabolite tanshinone IIA in rat plasma was developed and well validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. This method entailed a single step of liquid-liquid extraction with ethyl acetate from a small volume of plasmas. The analytes and internal standard diazepam were baseline separated on a Shim-pack VP-ODS analytical column. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization source operated under selected reaction monitoring (SRM) mode. The method was linear in the concentration range of 1-100 ng/ml for both tanshinone IIA and cryptotanshinone. The intra- and inter-day precisions (R.S.D.%) were within 10.2% for both analytes. Deviation of the assay accuracies was within +/-12.0% for both analytes. Both analytes were proved to be stable during all sample storing, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of cryptotanshinone to rats with a dose of 20 mg/kg. With the lower limits of quantification at 1.0 ng/ml for tanshinone IIA and 0.2 ng/ml for cryptotanshinone, this method was proved to be sensitive enough and reproducible for the pharmacokinetics study of both tanshinones. PMID:16169701

  3. Dynamic Biodistribution of Icaritin and Its Phase-II Metabolite in Rat Tissues by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Zhang, Shuang-Qing

    2016-01-01

    Icaritin (ICT), a major component in herb Epimedium brevicornum Maxim., shows beneficial effects for the treatment of osteoporosis and various cancers, and is predominantly metabolized to glucuronidated icaritin (GICT). Although clinical trials of ICT have exhibited good safety and tolerance, the dynamic bioditributions of ICT and GICT have not been reported. In the present study, the chemical structure of GICT was firstly reported, and a reliable ultra-high performance liquid chromatography-tandem mass spectrometry method (UHPLC-MS/MS) was firstly established for the simultaneous quantifications of ICT and GICT in rat tissues. The dynamic distribution of ICT and GICT in rat tissues and their pharmacokinetic parameters have been reported for the first time. ICT, GICT and the internal standard coumestrol were separated on a C18 column with a gradient mobile phase of acetonitrile and water containing ammonium formate and formic acid at a flow rate of 0.3 mL min(-1). The analytes were quantified by a triple quadrupole tandem mass spectrometer in the negative ionization mode. The lower limit of quantification values for ICT and GICT were 0.2 and 2 ng mL(-1), respectively. Good selectivity, linearity, accuracy, precision and recovery were achieved, and no significant matrix effect was observed. The UHPLC-MS/MS was firstly applied to a dynamic biodistribution study of ICT and GICT in rats, following an intraperitoneal administration of ICT at a dose of 10 mg kg(-1). PMID:27302583

  4. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column.

    PubMed

    Domingues, Diego Soares; Souza, Israel Donizeti de; Queiroz, Maria Eugênia Costa

    2015-07-01

    This study reports on the development of a rapid, selective, and sensitive column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze sixteen drugs (antidepressants, anticonvulsants, anxiolytics, and antipsychotics) in plasma samples from schizophrenic patients. The developed organic-inorganic hybrid monolithic column with cyanopropyl groups was used for the first dimension of the column-switching arrangement. This arrangement enabled online pre-concentration of the drugs (monolithic column) and their subsequent analytical separation on an XSelect SCH C18 column. The drugs were detected on a triple quadrupole tandem mass spectrometer (multiple reactions monitoring mode) with an electrospray ionization source in the positive ion mode. The developed method afforded adequate linearity for the sixteen target drugs; the coefficients of determination (R(2)) lay above 0.9932, the interassay precision had coefficients of variation lower than 6.5%, and the relative standard error values of the accuracy ranged from -14.0 to 11.8%. The lower limits of quantification in plasma samples ranged from 63 to 1250pgmL(-1). The developed method successfully analyzed the target drugs in plasma samples from schizophrenic patients for therapeutic drug monitoring (TDM).

  5. Identification and quantification of 34 drugs and toxic compounds in blood, urine, and gastric content using liquid chromatography with tandem mass spectrometry.

    PubMed

    Liang, Chen; Ye, Haiying; Wang, Rong; Ni, Chunfang; Rao, Yulan; Zhang, Yurong

    2015-05-01

    A liquid chromatography with tandem mass spectrometry method was developed for the simultaneous screening of 34 drugs and poisons in forensic cases. Blood (0.5 mL, diluted 1:1 with water) or 1.0 mL of urine was purified by solid-phase extraction. Gastric contents (diluted 1:1 with water) were treated with acetonitrile, centrifuged, and supernatant injected. Detection was achieved using a Waters Alliance 2695/Quattro Premier XE liquid chromatography tandem mass spectrometry system equipped with electrospray ionization, operated in the multiple reaction monitoring modes. The method was validated for accuracy, precision, linearity, and recovery. The absolute recovery of drugs and toxic compounds in blood was greater than 51% with the limit of detection in the range of 0.02-20 ng/mL. The absolute recovery of drugs and toxic compounds in urine was greater than 61% with limit of detection in the range of 0.01-10 ng/mL. The matrix effect of drugs and toxic compounds in urine was 65-117% and 67-121% in blood. The limit of detection of drugs and toxic compounds in gastric content samples were in the range of 0.05-20 ng/mL. This method was applied to the routine analysis of drugs and toxic compounds in postmortem blood, urine, and gastric content samples. The method was applied to actual forensic cases with examples given.

  6. Rapid simultaneous analysis of 17 haloacetic acids and related halogenated water contaminants by high-performance ion chromatography-tandem mass spectrometry.

    PubMed

    Xue, Runmiao; Donovan, Ariel; Shi, Honglan; Yang, John; Hua, Bin; Inniss, Enos; Eichholz, Todd

    2016-09-01

    Haloacetic acids (HAAs), which include chloroacetic acids, bromoacetic acids, and emerging iodoacetic acids, are toxic water disinfection byproducts. General screening methodology is lacking for simultaneously monitoring chloro-, bromo-, and iodoacetic acids. In this study, a rapid and sensitive high-performance ion chromatography-tandem mass spectrometry method for simultaneous determination of chloro-, bromo-, and iodo- acetic acids and related halogenated contaminants including bromate, bromide, iodate, and iodide was developed to directly analyze water samples after filtration, eliminating the need for preconcentration, and chemical derivatization. The resulting method was validated in both untreated and treated water matrices including tap water, bottled water, swimming pool water, and both source water and drinking water from a drinking water treatment facility to demonstrate application potential. Satisfactory accuracies and precisions were obtained for all types of tested samples. The detection limits of this newly developed method were lower or comparable with similar techniques without the need for extensive sample treatment requirement and it includes all HAAs and other halogenated compounds. This provides a powerful methodology to water facilities for routine water quality monitoring and related water research, especially for the emerging iodoacetic acids. Graphical abstract High performance ion chromatography-tandem mass spectrometry method for detection of haloacetic acids in water. PMID:27422643

  7. Determination of parabens in urine samples by microextraction using packed sorbent and ultra-performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Cristina Jardim, Valeria; de Paula Melo, Lidervan; Soares Domingues, Diego; Costa Queiroz, Maria Eugênia

    2015-01-01

    A simple, sensitive, and selective method using ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination of parabens [methyl paraben (MeP), ethyl paraben (EtP), propyl paraben (PrP), butyl paraben (BuP), and benzyl paraben (BzP)] in human urine samples. After microextraction by packed sorbent (MEPS) using a C18 phase, the parabens were separated on a Kinetex C18 column (100 mm × 2.1 mm × 1.7 μm) within 4.6 min using isocratic elution. These compounds were detected on a triple quadrupole tandem mass spectrometer using the multiple reactions monitoring (MRM) mode via an electrospray ionization source operating in the negative ionization mode. Important factors that influence MEPS performance were evaluated, such as the sample pH, draw-eject sample volume, clean-up step, and desorption conditions. The proposed MEPS/UPLC-MS/MS method presented a linear range from 0.5 ng mL(-1) (limit of quantification - LOQ) to 50 ng mL(-1), and interassay precision with coefficients of variation lower than 15%, and relative standard error values of the accuracy ranged from -8.8% to 15%. The MEPS/UPLC-MS/MS method was applied successfully to determine parabens in urine samples from 30 postpartum volunteers, enabling assessment of human exposure to these compounds.

  8. Rapid extraction and determination of 25 bioactive constituents in Alpinia oxyphylla using microwave extraction with ultra high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Sun, Zhi; Kong, Xiangzhen; Zuo, Lihua; Kang, Jian; Hou, Lei; Zhang, Xiaojian

    2016-02-01

    A novel and rapid microwave extraction and ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of 25 bioactive constituents (including two new constituents) in Fructus Alpinia oxyphylla. The optimized conditions of the microwave extraction was a microwave power of 300 W, extraction temperature of 80°C, solvent-to-solid ratio of 30 mL/g and extraction time of 8 min. Separation was achieved on a Waters ACQUITY UPLC(®) HSS C18 column (2.1 mm× 50 mm, 1.8 μm) using gradient elution with a mobile phase consisting of acetonitrile and 1 mM ammonium acetate at a flow rate of 0.2 mL/min. This is the first report of the simultaneous determination of 25 bioactive constituents in Fructus Alpinia oxyphylla by ultra high performance liquid chromatography with tandem mass spectrometry. The method was validated with good linearity, acceptable precision and accuracy. The validated method was successfully applied to determine the contents of 25 bioactive constituents in Fructus Alpinia oxyphylla from different sources and the analysis results were classified by hierarchical cluster analysis, which indicated the effect of different cultivation regions on the contents of constituents. This study provides powerful and practical guidance in the quality control of Alpinia oxyphylla and lays the foundation for further research of Alpinia oxyphylla.

  9. Quantitation of kudinoside A, kudinoside D and kudinoside F in human plasma using a high performance liquid chromatography-electrospray ionization tandem mass spectrometric method.

    PubMed

    Zhang, Wei; Guo, Jianru; Qiu, Hongcong; Wang, Caiyun; Chen, Qian Qian; Liu, Buming

    2014-12-01

    A sensitive and selective high performance liquid chromatography-tandem mass spectrometric (HPLC-MS/MS) method for the simultaneous determination of kudinoside A, kudinoside D and kudinoside F in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (35:65) at the flow rate of 0.3mL/min. The analytes and internal standard Ginsenoside Rb1 were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0ng/mL. The lower limit of quantification (LLOQ) was 2.5ng/mL. The intra-and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 12.4%. The accuracy determined at three concentrations was within ±4.9% in terms of relative error. The total run time was 7.0min. This assay offers advantages in terms of expediency, and suitability for the analysis of kudinoside A, kudinoside D and kudinoside F in various biological fluids.

  10. Matrix effect on the determination of synthetic corticosteroids and diuretics by liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Dikunets, M. A.; Appolonova, S. A.; Rodchenkov, G. M.

    2009-04-01

    This work presents a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) procedure for selective and reliable screening of corticosteroids and diuretics in human urine. Sample preparation included the extraction, evaporation of the organic extract under nitrogen, and solution of the dry residue. The extract was analyzed by HPLC combined with tandem mass spectrometry using electro-spraying ionization at atmospheric pressure with negative ion recording. The mass spectra of all compounds were recorded, and the characteristic ions, retention times, and detection limits were determined. The procedure was validated by evaluating the degree of the matrix suppression of ionization, extraction of analytes from human biological liquid, and the selectivity and specificity of determination.

  11. Assesment of endocrinal and biochemical entities through liquid chromatography–tandem mass spectrometry/mass spectrometer: Inter-relative investigation of the interaction based cardiovascular formulation

    PubMed Central

    Das, Rakesh; Pal, Tapan Kumar

    2015-01-01

    Background: Combinatory oral dosage treatment of atorvastatin (ATVS) and olmesartan (OLM) drugs to cardiovascular patients reflects unpredicted results instead of its individual therapy, which was accessed on quantification of endocrinal and biochemicals of plasma through liquid chromatography–tandem mass spectrometry/mass spectrometer (LCMS/MS). Objective: Mission was to track the remarkable biochemical variation in the plasma after induction of the combined formulation, to evaluate the pharma-market rumor on its efficiency. Methods: To fulfil undergoing research objectives for digging-up of market insult, human patient volunteers were chosen according to the required criteria along with bioethical regulation. A sensitive, rapid and precise method was developed and validated to estimate aldosterone (ALD), angiotensin (ANG-II) and the Mevalonate (MVA) not Mevalonic acid through LCMS/MS over least samples of cardiovascular patients. Level of each endogenous biochemicals were determined in three stages - without drugs, with a single drug (OLM/ATVS) and with their combination that was then correlate with blood pressure of respective volunteers. Result and Discussion: Comparative and correlative studies panaroma among these analytes was detected. The selectivity, specificity, linearity, precision, accuracy, extraction recovery, limit of detection and limit of quantification, stability were the essential points of validation of the developed methodology. And the significance of each endogenous analyte data were based on P ≥ 0.001. Thus, low value of ALD and reciprocally higher in ANG-II on administered single drug than its combination and equal concentration of mevalonate in both stages, was discovered. Conclusion: This concludes that the cardiovascular dosage formulation entrenched in the market are not synergistic and effective compared with a single drug as antihypertensive drug. PMID:25709337

  12. Construction of an Ultrahigh Pressure Liquid Chromatography-Tandem Mass Spectral Library of Plant Natural Products and Comparative Spectral Analyses.

    PubMed

    Lei, Zhentian; Jing, Li; Qiu, Feng; Zhang, Hua; Huhman, David; Zhou, Zhiqin; Sumner, Lloyd W

    2015-07-21

    A plant natural product tandem mass spectral library has been constructed using authentic standards and purified compounds. Currently, the library contains 1734 tandem mass spectra for 289 compounds, with the majority (76%) of the compounds being plant phenolics such as flavonoids, isoflavonoids, and phenylpropanoids. Tandem mass spectra and chromatographic retention data were acquired on a triple quadrupole mass spectrometer coupled to an ultrahigh pressure liquid chromatograph using six different collision energies (CEs) (10-60 eV). Comparative analyses of the tandem mass spectral data revealed that the loss of ring substituents preceded the C-ring opening during the fragmentation of flavonoids and isoflavonoids. At lower CE (i.e., 10 and 20 eV), the flavonoids and isoflavonoid central ring structures typically remained intact, and fragmentation was characterized by the loss of the substituents (i.e., methyl and glycosyl groups). At higher CE, the flavonoid and isoflavonoid core ring systems underwent C-ring cleavage and/or rearrangement depending on the structure, particularly hydroxylation patterns. In-source electrochemical oxidation was observed for phenolics that had ortho-diphenol moieties (i.e., vicinal hydroxyl groups on the aromatic rings). The ortho-diphenols were oxidized to ortho-quinones, yielding an intensive and, in most cases, a base ion peak corresponding to a [(M - 2H) - H](-) ion in their mass spectra. The library also contains reverse-phase retention times, allowing for the construction, validation, and testing of an artificial neural network retention prediction of other flavonoids and isoflavonoids not contained within the library. The library is freely available for nonprofit, academic use and it can be downloaded at http://www.noble.org/apps/Scientific/WebDownloadManager/DownloadArea.aspx. PMID:26107650

  13. Construction of an Ultrahigh Pressure Liquid Chromatography-Tandem Mass Spectral Library of Plant Natural Products and Comparative Spectral Analyses.

    PubMed

    Lei, Zhentian; Jing, Li; Qiu, Feng; Zhang, Hua; Huhman, David; Zhou, Zhiqin; Sumner, Lloyd W

    2015-07-21

    A plant natural product tandem mass spectral library has been constructed using authentic standards and purified compounds. Currently, the library contains 1734 tandem mass spectra for 289 compounds, with the majority (76%) of the compounds being plant phenolics such as flavonoids, isoflavonoids, and phenylpropanoids. Tandem mass spectra and chromatographic retention data were acquired on a triple quadrupole mass spectrometer coupled to an ultrahigh pressure liquid chromatograph using six different collision energies (CEs) (10-60 eV). Comparative analyses of the tandem mass spectral data revealed that the loss of ring substituents preceded the C-ring opening during the fragmentation of flavonoids and isoflavonoids. At lower CE (i.e., 10 and 20 eV), the flavonoids and isoflavonoid central ring structures typically remained intact, and fragmentation was characterized by the loss of the substituents (i.e., methyl and glycosyl groups). At higher CE, the flavonoid and isoflavonoid core ring systems underwent C-ring cleavage and/or rearrangement depending on the structure, particularly hydroxylation patterns. In-source electrochemical oxidation was observed for phenolics that had ortho-diphenol moieties (i.e., vicinal hydroxyl groups on the aromatic rings). The ortho-diphenols were oxidized to ortho-quinones, yielding an intensive and, in most cases, a base ion peak corresponding to a [(M - 2H) - H](-) ion in their mass spectra. The library also contains reverse-phase retention times, allowing for the construction, validation, and testing of an artificial neural network retention prediction of other flavonoids and isoflavonoids not contained within the library. The library is freely available for nonprofit, academic use and it can be downloaded at http://www.noble.org/apps/Scientific/WebDownloadManager/DownloadArea.aspx.

  14. Quantitative analysis of positional isomers of triacylglycerols via electrospray ionization tandem mass spectrometry of sodiated adducts.

    PubMed

    Herrera, Lisandra Cubero; Potvin, Michael A; Melanson, Jeremy E

    2010-09-01

    Herein we report a reversed-phase high-performance liquid chromatography tandem mass spectrometry (RP-HPLC/MS/MS) method for the analysis of positional isomers of triacylglycerols (TAGs) in vegetable oils. The fragmentation behavior of [M + X](+) ions (X = NH(4), Li, Na or Ag) was studied on a quadrupole-time-of-flight (Q-TOF) mass spectrometer under low-energy collision-induced dissociation (CID) conditions. Mass spectra that were dependent on the X(+) ion and the nature and position of the acyl substituents were observed for four pairs of 'AAB/ABA'-type TAGs, namely PPO/POP, OOP/OPO, LLO/LOL and OOL/OLO (where P is 16:0, palmitic acid; O is 18:1, oleic acid; and L is 18:2, linoleic acid). For the majority of [M + X](+) adducts, the loss of the fatty acid in the outer positions (sn-1 or sn-3) was favored over the loss in the central position (sn-2), which enabled the determination of the fractional abundance of the isomers. Ratios of the intensity of fragment ions at various AAB/ABA compositions produced linear calibration curves with positive slopes, comparable to those obtained traditionally by ESI-MS/MS of [M + NH(4)](+) adducts. The only exceptions were the [M + Ag](+) adducts of the PPO/POP system, which produced calibration curves with negative slopes. Sodium adducts provided the most consistent level of isomeric discrimination for the TAGs studied and also offered the most convenience in that they required no additive to the mobile phase. Therefore, calibration curve data derived from [M + Na](+) adducts were applied to the quantification of TAG regioisomers in sunflower and olive oils. The regiospecific analysis showed that palmitic acid was typically located at positions sn-1 or sn-3, whereas unsaturated fatty acids, oleic and linoleic acids were mostly found at the sn-2 position. PMID:20814981

  15. Characterization of N-Succinylation of L-Lysylphosphatidylglycerol in Bacillus subtilis Using Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Atila, Metin; Katselis, George; Chumala, Paulos; Luo, Yu

    2016-10-01

    Phospholipids generally dominate in bacterial lipids. The negatively charged nature of phospholipids renders bacteria susceptible to cationic antibiotic peptides. In comparison with Gram-negative bacteria, Gram-positive bacteria in general have much less zwitterionic phosphatidylethanolamine. However, they are known for producing aminoacylated phosphatidylglycerol (PG), especially positively charged l-lysyl-PG, which is catalyzed by lysyl-PG synthase MprF, which appears to have a broad range of specificity for l-aminoacyl transfer RNAs. In addition, many Gram-positive bacteria also have a dlt-gene-coded d-alanylation pathway for lipoteichoic acids and wall teichoic acids covalently attached to a glycolipid or peptidoglycan. d-Alanylation also masks the dominant negative charge of the phosphate-rich polymers of teichoic acids. Using mass spectrometry, we have recently observed that precursor scans in negative mode for deprotonated amino acid fragments were most sensitive for ester-linked amino acids. Such a scan for precursors generating an m/ z 145 lysyl anion revealed lysyl-PG as well as an additional species 100 m/ z units greater than lysyl-PG. This unexpected species corresponded precisely to the expected mass of N-succinylated lysyl-PG. Tandem mass spectrometry revealed a precise match to the fragmentation pattern of this putative new species. PG, lysyl-PG, and N-succinyl-lysyl-PG may form a complete loop of charge reversal from -1 to +1 and then back to -1. Analogous charge reversal by N-succinylation of lysine residues in the bacterial as well as eukaryotic proteomes has been recently discovered as a major posttranslational modification. Such modification in bacterial lipids is possibly catalyzed by an enzyme homologous to the enzymes that modify lysine residues in proteins.

  16. Investigation of silver binding to polyamidoamine (PAMAM) dendrimers by ESI tandem mass spectrometry.

    PubMed

    Mazzitelli, Carolyn L; Brodbelt, Jennifer S

    2006-05-01

    Electrospray ionization tandem mass spectrometry (ESI-MS/MS) was used to probe the binding of silver ions and reduced silver species with polyamidoamine generation 1 amine-terminated (PAMAMG1NH2) and generation 2 hydroxyl-terminated (PAMAMG2OH) dendrimers. At Ag(+)/PAMAMG2OH molar ratios of 1, 2:1 and low abundance 3:1 complexes emerge. Similar results were observed for PAMAMG1NH2. The collisional activated dissociation (CAD) patterns of the dendrimer ions are characterized by losses of amidoamine branches resulting largely from hydrogen migration and cleavage reactions. Ag+/dendrimer complexes are characterized by the loss of a dendrimer branch from the complex, with the silver ion remaining bound to a dendrimer fragment. When the Ag+-bound dendrimer complexes are reduced by hydrazine, low abundance complexes, whose m/z values are consistent with ones containing zerovalent silver species, are observed in the mass spectra. Complexes with three silver atoms are observed in the spectrum containing PAMAMG1NH2, and complexes with four and five silver atoms are observed with PAMAMG2OH. The CAD fragmentation patterns of the complexes formed after the silver reduction are different than those observed for complexes containing one silver ion and are characterized by the ejection of all silver species, possibly as a cluster, leaving the intact dendrimer ion. Experiments with Cu+, Cu2+, and Pt2+ binding to PAMAMG2OH were also done, but reduced metal clusters were not observed in the mass spectra after the addition of hydrazine. PMID:16516486

  17. Characterization of N-Succinylation of L-Lysylphosphatidylglycerol in Bacillus subtilis Using Tandem Mass Spectrometry.

    PubMed

    Atila, Metin; Katselis, George; Chumala, Paulos; Luo, Yu

    2016-10-01

    Phospholipids generally dominate in bacterial lipids. The negatively charged nature of phospholipids renders bacteria susceptible to cationic antibiotic peptides. In comparison with Gram-negative bacteria, Gram-positive bacteria in general have much less zwitterionic phosphatidylethanolamine. However, they are known for producing aminoacylated phosphatidylglycerol (PG), especially positively charged L-lysyl-PG, which is catalyzed by lysyl-PG synthase MprF, which appears to have a broad range of specificity for L-aminoacyl transfer RNAs. In addition, many Gram-positive bacteria also have a dlt-gene-coded D-alanylation pathway for lipoteichoic acids and wall teichoic acids covalently attached to a glycolipid or peptidoglycan. D-Alanylation also masks the dominant negative charge of the phosphate-rich polymers of teichoic acids. Using mass spectrometry, we have recently observed that precursor scans in negative mode for deprotonated amino acid fragments were most sensitive for ester-linked amino acids. Such a scan for precursors generating an m/z 145 lysyl anion revealed lysyl-PG as well as an additional species 100 m/z units greater than lysyl-PG. This unexpected species corresponded precisely to the expected mass of N-succinylated lysyl-PG. Tandem mass spectrometry revealed a precise match to the fragmentation pattern of this putative new species. PG, lysyl-PG, and N-succinyl-lysyl-PG may form a complete loop of charge reversal from -1 to +1 and then back to -1. Analogous charge reversal by N-succinylation of lysine residues in the bacterial as well as eukaryotic proteomes has been recently discovered as a major posttranslational modification. Such modification in bacterial lipids is possibly catalyzed by an enzyme homologous to the enzymes that modify lysine residues in proteins. Graphical Abstract ᅟ. PMID:27506207

  18. Quantitative, Multidrug Pain Medication Testing by Liquid Chromatography: Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Bodor, Geza S

    2016-01-01

    Chronic pain is often treated with narcotic analgesics. The most commonly used narcotic analgesics are the opiates (natural or modified compounds of the poppy plant) or opioids (synthetic chemicals that act on opiate receptors). While opiates and opioids are excellent analgesics, they can also have significant side effects that include respiratory depression, coma, or death. Tolerance, physical dependence, and addiction (psychological dependence) are other severe side effects of opioid use. Patients who develop dependence or addiction often times abuse other, non-opioid narcotics and may trade their prescription medication for illegal street drugs (called "diversion"). In order to minimize side effects, detect possible multidrug abuse and prove diversion, simultaneous monitoring of numerous prescription and illicit drugs is required. The method described in this chapter is for the quantitative measurement of 43 different drugs in urine. The panel includes narcotic pain medications, benzodiazepines, NIDA drugs, and other, commonly abused medications. The analytes of interests are injected in the presence of deuterated internal standards to correct for possible extraction inefficiencies, ion suppression, or other interferences. The sample is prepared by adding dilution buffer with the deuterated internal standards to the sample, followed by reversed-phase, gradient HPLC separation on a Phenyl-Hexyl column using water and methanol as mobile phases. Detection of the analytes of interest is done by isotope-dilution mass spectrometry on a triple-quadrupole tandem mass spectrometer following electrospray ionization in the positive mode. Mass spectrometric (MS) data are collected in the scheduled MRM (sMRM) mode. Two MRM transitions are monitored for each analyte and one MRM transition is monitored for each IS. Quantitation of the unknown analytes is achieved by comparing the peak area ratios of the analytes to that of the internal standards and reading the unknown

  19. Characterization of N-Succinylation of L-Lysylphosphatidylglycerol in Bacillus subtilis Using Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Atila, Metin; Katselis, George; Chumala, Paulos; Luo, Yu

    2016-08-01

    Phospholipids generally dominate in bacterial lipids. The negatively charged nature of phospholipids renders bacteria susceptible to cationic antibiotic peptides. In comparison with Gram-negative bacteria, Gram-positive bacteria in general have much less zwitterionic phosphatidylethanolamine. However, they are known for producing aminoacylated phosphatidylglycerol (PG), especially positively charged uc(l)-lysyl-PG, which is catalyzed by lysyl-PG synthase MprF, which appears to have a broad range of specificity for uc(l)-aminoacyl transfer RNAs. In addition, many Gram-positive bacteria also have a dlt-gene-coded uc(d)-alanylation pathway for lipoteichoic acids and wall teichoic acids covalently attached to a glycolipid or peptidoglycan. uc(d)-Alanylation also masks the dominant negative charge of the phosphate-rich polymers of teichoic acids. Using mass spectrometry, we have recently observed that precursor scans in negative mode for deprotonated amino acid fragments were most sensitive for ester-linked amino acids. Such a scan for precursors generating an m/z 145 lysyl anion revealed lysyl-PG as well as an additional species 100 m/z units greater than lysyl-PG. This unexpected species corresponded precisely to the expected mass of N-succinylated lysyl-PG. Tandem mass spectrometry revealed a precise match to the fragmentation pattern of this putative new species. PG, lysyl-PG, and N-succinyl-lysyl-PG may form a complete loop of charge reversal from -1 to +1 and then back to -1. Analogous charge reversal by N-succinylation of lysine residues in the bacterial as well as eukaryotic proteomes has been recently discovered as a major posttranslational modification. Such modification in bacterial lipids is possibly catalyzed by an enzyme homologous to the enzymes that modify lysine residues in proteins.

  20. Correction of errors in tandem mass spectrum extraction enhances phosphopeptide identification.

    PubMed

    Hao, Piliang; Ren, Yan; Tam, James P; Sze, Siu Kwan

    2013-12-01

    The tandem mass spectrum extraction of phosphopeptides is more difficult and error-prone than that of unmodified peptides due to their lower abundance, lower ionization efficiency, the cofragmentation with other high-abundance peptides, and the use of MS(3) on MS(2) fragments with neutral losses. However, there are still no established methods to evaluate its correctness. Here we propose to identify and correct these errors via the combinatorial use of multiple spectrum extraction tools. We evaluated five free and two commercial extraction tools using Mascot and phosphoproteomics raw data from LTQ FT Ultra, in which RawXtract 1.9.9.2 identified the highest number of unique phosphopeptides (peptide expectation value <0.05). Surprisingly, ProteoWizzard (v. 3.0.3476) extracted wrong precursor mass for most MS(3) spectra. Comparison of the top three free extraction tools showed that only 54% of the identified spectra were identified consistently from all three tools, indicating that some errors might happen during spectrum extraction. Manual check of 258 spectra not identified from all three tools revealed 405 errors of spectrum extraction with 7.4% in selecting wrong precursor charge, 50.6% in selecting wrong precursor mass, and 42.1% in exporting MS/MS fragments. We then corrected the errors by selecting the best extracted MGF file for each spectrum among the three tools for another database search. With the errors corrected, it results in the 22.4 and 12.2% increase in spectrum matches and unique peptide identification, respectively, compared with the best single method. Correction of errors in spectrum extraction improves both the sensitivity and confidence of phosphopeptide identification. Data analysis on nonphosphopeptide spectra indicates that this strategy applies to unmodified peptides as well. The identification of errors in spectrum extraction will promote the improvement of spectrum extraction tools in future.

  1. The Accuracies of Smoothed SSH Fields and Geostrophic Velocity Estimates from the Tandem TOPEX/POSEIDON and Jason Altimeter Mission

    NASA Astrophysics Data System (ADS)

    Chelton, D. B.; Schlax, M. G.

    2002-12-01

    Jason-1 was launched on 7 December 2001 and the altimeter data record began on 15 January 2002. The Jason altimeter operated in phase with TOPEX/POSEIDON (T/P) for 7 months, sampling the same 10-day exact-repeat ground track 72 seconds ahead of T/P. On 15 August 2002, a series of maneuvers was initiated to shift T/P to a different 10-day exact-repeat orbit with ground tracks half way between the ground track pattern established during the first 10 years of the mission and continued with the Jason mission. The interleaved sampling pattern with evenly spaced ground tracks afforded by this coordinated tandem mission will enable scientific investigations that have not heretofore been possible. Examples include significant improvements in the understanding of the wavenumber-frequency spectral characteristics of sea surface height (SSH) variability and the effects of eddy Reynolds stresses on the slowly varying background currents. A prerequisite to such scientific studies is a quantitative assessment of the errors of SSH fields and geostrophic velocity estimates obtainable from the coordinated tandem T/P-Jason altimeter mission. The root mean squared (rms) errors of smoothed SSH fields constructed from the tandem dataset are more than a factor of two smaller than those obtainable from T/P or Jason data alone. The rms errors of each geostrophic velocity component estimated by the parallel-track method with this track spacing are larger than 80% of the signal standard deviation between latitudes 10° and 45°, even with residual orbit errors as small as 1 cm. With suitable along-track smoothing, the rms errors of crossover estimates of both geostrophic velocity components are smaller than 30% of the signal standard deviation between latitudes 5° and 60°. The quadrupling of the number of crossovers from the sampling pattern of the tandem T/P-Jason mission compared with what is obtained from a single altimeter will greatly enhance the ability to investigate eddy-mean flow

  2. [Simultaneous determination of clevidipine butyrate and its metabolite clevidipine acid in dog blood by liquid chromatography-tandem mass spectrometry].

    PubMed

    Wei, Hui-hui; Gu, Yuan; Liu, Yan-ping; Wei, Guang-li; Chen, Yong; Liu, Chang-xiao; Si, Duan-yun

    2015-10-01

    A rapid, sensitive and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of clevidipine butyrate and its primary metabolite clevidipine acid in dog blood. After one-step protein precipitation with methanol, the chromatographic separation was carried out on an Ecosil C18 column (150 mm x 4.6 mm, 5 µm) with a gradient mobile phase consisting of methanol and 5 mmol · L(-1) ammonium formate. A chromatographic total run time of 13.0 min was achieved. The quantitation analysis was performed using multiple reaction monitoring (MRM) at the specific ion transitions of m/z 454.1 [M-H]- --> m/z 234.1 for clevidipine butyrate, m/z 354.0 [M-H]- --> m/z 208.0 for clevidipine acid and m/z 256.1 [M-H]- --> m/z 227.1 for elofesalamide (internal standard, IS) in the negative ion mode with electrospray ionization (ESI) source. The linear calibration curves for clevidipine butyrate and clevidipine acid were obtained in the concentration ranges of 0.5-100 ng · mL and 1-200 ng · mL(-1), separately. The lower limit of quantification of clevidipine butyrate and clevidipine acid were 0.5 ng · mL(-1) and 1 ng · mL(-1). The intra and inter-assay precisions were all below 12.9%, the accuracies were all in standard ranges. Stability testing indicated that clevidipine butyrate and clevidipine acid in dog blood with the addition of denaturant methanol was stable under various processing and/or handling conditions. The validated method has been successfully applied to a pharmacokinetic study of clevidipine butyrate injection to 8 healthy Beagle dogs following intravenous infusion at a flow rate of 5 mg · h(-1) for 0.5 h.

  3. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography-tandem mass spectrometry.

    PubMed

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K

    2015-09-01

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively.

  4. Development and validation of a liquid chromatography-tandem mass spectrometry method for quantification of decitabine in rat plasma.

    PubMed

    Xu, Haiyan; Lv, Shaoqiong; Qiao, Mingxi; Fu, Yao; Jiang, Xue; Jin, Yi; Li, Chibing; Yuan, Bo

    2012-06-15

    Decitabine is chemically unstable at physiological temperature and pH. In addition, the bioanalysis of decitabine is easily interfered by endogenous 2-deoxycytidine. A simple, sensitive and specific LC-MS/MS method was developed for the analysis of decitabine in rat plasma. No exogenous stabilizers were used to prevent the degradation of decitabine in rat plasma. After deproteinized with acetonitrile at room temperature, rat plasma samples were analyzed on a Hypersil APS-2 NH₂ column interfaced with a triple quadrupole tandem mass spectrometer in positive electrospray ionization mode. Decitabine was completely separated from 2-deoxycytidine using gradient elution of water (solvent A) and acetonitrile (solvent B) at a flow rate of 1 mL/min. To quantify decitabine and daidzin (internal standard), respectively, multiple reaction monitoring (MRM) transitions of m/z 251.1→134.7 and m/z 417.3→255.3 was performed. The assay was linear over the concentration range of 5.0-2000 ng/mL. The intra- and inter-day precision was within 12.0% in terms of relative standard deviation (RSD%) and the accuracy within 5.9% in terms of relative error. The LC-MS/MS method was fully validated for its sensitivity, selectivity, stability study, matrix effect and recovery. The data indicate that this LC-MS/MS method is a specific and effective method for the pharmacokinetic study of decitabine in rat plasma. Compared with the previously reported analytical methods, this method showed easy and economic sample preparation, good specificity and high sensitivity with less plasma (50 μL).

  5. Simultaneous quantitative analysis of eight vitamin D analogues in milk using liquid chromatography-tandem mass spectrometry.

    PubMed

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Hewavitharana, Amitha K

    2015-09-01

    Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30-13.5%, and 88.2-105%, respectively. PMID:26388380

  6. Quantification of vincristine and its major metabolite in human plasma by high-performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Dennison, Jennifer B; Renbarger, Jamie L; Walterhouse, David O; Jones, David R; Hall, Stephen D

    2008-06-01

    An analytical method using electrospray ionization and high-performance liquid chromatography/tandem mass spectrometry (LC/ESI-MS/MS) was developed to quantify vincristine and M1, the CYP3A-mediated metabolite of vincristine, in human plasma. Vinblastine (internal standard), vincristine, and M1 in plasma were extracted in methylene chloride after acidification with TCAA. The analytes were separated on an Inertsil ODS-3 C18 column (2.1 x 150 mm) with a 5-mum particle size using a gradient elution with a run time of 20 min. The initial mobile phase composition was 0.2% formic acid/water (80:20, v/v) with a final composition of 0.2% formic acid/water (20:80, v/v). Detection was accomplished with multiple reaction monitoring for vinblastine (m/z 406.3--> 271.7), vincristine (m/z 413.2--> 362.2), and M1 (m/z 397.3 --> 376.2). At three concentrations of vincristine and M1, the inter-day and intra-day accuracy and precision were within the acceptable limits for validation (106.8 +/- 9.6% for intra-day, n = 5 each concentration; 90.9 +/- 10.9% for inter-day, n = 4 each concentration). For both vincristine and M1, the concentration limits of quantification and detection were 12 pg/mL and 6 pg/mL, respectively. Stability studies indicated that 80% of M1 degraded in plasma after 15 hours at room temperature (n = 3, high and low QC concentrations). Therefore, short plasma processing times (<30 min) are recommended. The assay was used successfully to quantify vincristine and M1 in pediatric plasma samples up to 24 hours after vincristine administration. Vincristine and M1 concentrations were within the limits of quantification for all patient plasma samples.

  7. Liquid chromatography-electrospray ionization tandem mass spectrometric analysis of 2-alkylcyclobutanones in irradiated chicken by precolumn derivatization with hydroxylamine.

    PubMed

    Ye, Yuran; Liu, Hanxia; Horvatovich, Peter; Chan, Wan

    2013-06-19

    Food irradiation is a common preservation method that is used in many countries. The ability to identify irradiated food is important for assuring compliance with regulatory policies, such as food labeling requirements, and for informed consumer choice. There is thus a significant demand for analytical methods of high sensitivity and selectivity to identify irradiated food, especially for foods subjected to low-dose irradiation and for processed or composite foods that contain small quantities of irradiated ingredients. 2-Alkylcyclobutanones (2-ACBs) are uniquely formed during food irradiation and have been adopted by the European Committee for Standardization as signature biomarkers for the identification of irradiated foods. We now report the development of a novel assay for quantification of 2-ACBs in γ-irradiated food by liquid extraction of fat content followed by precolumn derivatization and liquid chromatography-tandem mass spectrometric (LC-MS/MS) detection. Precolumn derivatization with hydroxylamine introduced a polar functional group into the otherwise nonpolar 2-ACBs, which greatly enhanced ESI-MS response. The method was validated for extraction efficiency, precision, accuracy, and detection limit. In comparison with the current GC-MS based European official method (EN1785:2003) for 2-ACBs determination, our new LC-MS/MS method offers a more efficient sample processing protocol with reduced solvent consumption. More importantly, the combination of chemical derivatization and LC-MS/MS detection significantly enhanced the analytical sensitivity of the method, which allows confident identification of food irradiated with as little as 10 Gy. To the best of our knowledge, this is the first report of 2-ACB determination by LC-MS/MS and the first analytical method allowing confident identification of irradiated food at dosage of down to 10 Gy.

  8. Pharmacokinetics in rats and tissue distribution in mouse of magnoflorine by ultra performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Bao, Shihui; Geng, Peiwu; Wang, Shuanghu; Zhou, Yunfang; Hu, Lufeng; Yang, Xuezhi

    2015-01-01

    Magnoflorine is one of the most widespread aporphine alkaloids. In this work, a sensitive and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of magnoflorine in rat plasma and mouse tissue have been developed and validated. After addition of nuciferine as an internal standard (IS), protein precipitation by acetonitrile-methanol (9:1, v/v) was used for samples treatment. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 mm×100 mm, 1.7 μm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reactions monitoring (MRM) mode was used for quantification using target fragment ions m/z 342.8→298.2 for magnoflorine and m/z 296.0→265.1 for IS. Calibration plots were linear throughout the range 2-2000 ng/mL for magnoflorine in rat plasma and tissue. Mean recoveries of magnoflorine in rat plasma were better than 83.0%. RSD of intra-day and inter-day precision were both less than 9%. The accuracy of the method was between 95.5% and 107.5%. The method was successfully applied to pharmacokinetics and tissue distribution study of magnoflorine. The absolute bioavailability of magnoflorine was reported as 22.6%. The magnoflorine underwent a rapid and wide distribution to tissues; the level of magnoflorine in liver is highest, then followed by heart, spleen and lung. Based on tissue distribution data, a back-propagation artificial neural network (BP-ANN) method was developed and it could be used to predict the concentrations of magnoflorine in tissues. PMID:26884929

  9. Simultaneous determination of macitentan and its active metabolite in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Yu, Lixiu; Zhou, Ying; He, Xiaomeng; Li, Huqun; Chen, Hui; Li, Weiyong

    2015-10-01

    Macitentan is a newly approved endothelin receptor antagonist (ERA) for the long-term treatment of PAH with superior receptor-binding properties and a longer duration of action compared to other available ERAs. However, analytical methods for simultaneous determination of macitentan and its active metabolite, ACT-132577, in human plasma have not been fully reported in the literature. In this work, a fast, sensitive, and reliable high-performance liquid chromatography-tandem mass spectrometry method (HPLC-MS/MS) was firstly developed and completely validated for simultaneous determination of macitentan and its active metabolite in human plasma. Plasma samples were processed with a protein precipitation using acetonitrile, followed by chromatographic separation using an Inertsil ODS-SP column (100×2.1mm, 3.5μm) under isocratic elution with a mobile phase consisting of acetonitrile and 0.2% formic acid at a flow rate of 0.3mL/min. Quantification was operated in multiple reaction monitoring (MRM) mode using the transitions m/z 547.1→201.0 for macitentan, m/z 589.0→203.0 for ACT-132577, and m/z 380.5→243.3 for the IS (donepezil). The assay exhibited a linear range of 1-500ng/mL for both macitentan and ACT-132577. The accuracy and the intra- and inter-precisions were within acceptable ranges and no significant matrix effect was observed during the method validation. The developed method was successfully utilized to a human pharmacokinetic study of macitentan as well as ACT-132577 after oral administration of 10mg macitentan tablet in healthy Chinese volunteers.

  10. Pharmacokinetic study of ACT-132577 in rat plasma by ultra performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Zhang, Jin; Geng, Peiwu; Luo, Xinhua; Zhou, Genzhi; Lin, Yingying; Zhang, Lijing; Wang, Shuanghu; Wen, Congcong; Ma, Jianshe; Ding, Ting

    2015-01-01

    It was reported that macitentan was metabolized predominantly by cytochrome P450 3A4, and ACT-132577, its pharmacologically active metabolite, is fivefold less potent at blocking ET receptors than macitentan. In this work, a sensitive and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determination of ACT-132577 in rat plasma was developed and validated. After addition of diazepam as an internal standard (IS), protein precipitation by acetonitrile was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) with 0.2% formic acid and methanol as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reactions monitoring (MRM) mode was used for quantification using target fragment ions m/z 546.9→200.6 for ACT-132577, and m/z 285.1→193.1 for IS. Calibration plots were linear throughout the range 10-4000 ng/mL for ACT-132577 in rat plasma. Mean recovery of ACT-132577 in rat plasma ranged from 82.6% to 90.6%, matrix effect of ACT-132577 in rat plasma ranged from 101.4% to 115.2%. RSD of intra-day and inter-day precision were both less than 11%. The accuracy of the method ranged from 96.1% to 103.5%. The method was successfully applied to pharmacokinetic study of ACT-132577 after oral and intravenous administration of macitentan. PMID:26770447

  11. Pharmacokinetic study of ACT-132577 in rat plasma by ultra performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Jin; Geng, Peiwu; Luo, Xinhua; Zhou, Genzhi; Lin, Yingying; Zhang, Lijing; Wang, Shuanghu; Wen, Congcong; Ma, Jianshe; Ding, Ting

    2015-01-01

    It was reported that macitentan was metabolized predominantly by cytochrome P450 3A4, and ACT-132577, its pharmacologically active metabolite, is fivefold less potent at blocking ET receptors than macitentan. In this work, a sensitive and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determination of ACT-132577 in rat plasma was developed and validated. After addition of diazepam as an internal standard (IS), protein precipitation by acetonitrile was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) with 0.2% formic acid and methanol as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reactions monitoring (MRM) mode was used for quantification using target fragment ions m/z 546.9→200.6 for ACT-132577, and m/z 285.1→193.1 for IS. Calibration plots were linear throughout the range 10-4000 ng/mL for ACT-132577 in rat plasma. Mean recovery of ACT-132577 in rat plasma ranged from 82.6% to 90.6%, matrix effect of ACT-132577 in rat plasma ranged from 101.4% to 115.2%. RSD of intra-day and inter-day precision were both less than 11%. The accuracy of the method ranged from 96.1% to 103.5%. The method was successfully applied to pharmacokinetic study of ACT-132577 after oral and intravenous administration of macitentan.

  12. Fluoroquinolone residues in compost by green enhanced microwave-assisted extraction followed by ultra performance liquid chromatography tandem mass spectrometry.

    PubMed

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Viti, Simona; Sbarbada, Davide; Profumo, Antonella

    2015-09-01

    A novel, simple and straightforward method for determination of fluoroquinolones (FQs) in compost has been developed. The procedure entails a low-pressurized microwave-assisted extraction (MAE) carried out by a high performance instrument, in alkaline aqueous solution containing magnesium ions as FQs complexing agent, followed by ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS). Ciprofloxacin (CIP), Enrofloxacin (ENR), Levofloxacin (LEV) and Norfloxacin (NOR), four widely used FQ antibiotics, were simultaneously extracted from compost by a single MAE cycle (20min, 135°C). The method was validated in terms of linearity, selectivity, sensitivity and accuracy. Quantitative absolute recovery (70-112%, n=3) and suitable precision (RSD<15%, n=3) were observed, at concentration levels ranging from 25 ng g(-1) to 2500 ng g(-1). Analytes were separated in a 10min chromatographic run and quantified/confirmed in single reaction monitoring (SRM) mode. UPLC coupled to SRM-MS detection allowed to achieve improved sensitivity, and selective detection. Method detection and quantification limits, MDLs and MQLs, were in the range 2.2-3.0 ng g(-1) and 6.6-9.0 ng g(-1), respectively. The high-performance microwave system here used strongly improved the extraction efficiency with respect to a conventional apparatus. The procedure proved to be simpler, less expensive, faster, and more green with respect to the few methods currently described in literature, providing at the same time suitable recovery and reproducibility. The analytical method has been applied to the analysis of actual compost samples, wherein FQs have been quantified at concentrations up to 88 ng g(-1).

  13. [Determination of 22 acidic dyes in edible packagings by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Su, Youzhi; Liu, Jun; Li, Fang; Lei, Hongqin; Li, Yanmei; Liu, Xubin

    2015-04-01

    A method for the simultaneous determination of 22 acidic dyes (acid yellow 23, acid red 18, acid blue 7, etc) in edible packagings was developed using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The samples were extracted with acetonitrile-methanol (5:5, v/v) , and then cleaned up with Strata-X-AW solid-phase extractor. The analytes were separated on a Zorbax Eclipse Plus C18 column (100 mm x 3.0 mm, 1.8 µm) by gradient elution with acetonitrile-10 mmol/L ammonium acetate as the mobile phases. The 22 acidic dyes were determined by electrospray negative ion source (ESI-), and multiple reaction monitoring (MRM) mode. The qualitative analysis was based on the retention times and characteristic ion pairs consisting of one parent ion and two fragment ions, and the quantitative analysis was carried out by matrix-matched external standard method. The results showed that the calibration curves had good linearity for the 22 acidic dyes, and the correlation coefficients (r2) were larger than 0. 991. The limits of quantitation (LOQs, S/N ≥ 10) were in the range of 0.1-2.0 mg/kg in three different matrices (plant capsule, gelatine capsule, oblatum). The average recoveries were in the range of 78.4%-109.5% for the 22 acidic dyes with the relative standard deviations (RSDs) from 4.6% to 14.5% at three spiked levels (1 x LOQ, 2 x LOQ and 10 x LOQ). This method is suitable for the determination of acidic dyes in edible packagings with the characteristics of high accuracy and precision. PMID:26292405

  14. Determination of fungicides in wine by mixed-mode solid phase extraction and liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Carpinteiro, I; Ramil, M; Rodríguez, I; Cela, R

    2010-11-26

    A novel procedure for the determination of nine selected fungicides (metalaxyl-M, azoxystrobin, myclobutanil, flusilazole, penconazole, tebuconazole, propiconazole, diniconazole and difenoconazole) in wine samples is presented. Sample enrichment and purification is simultaneously performed using mixed-mode, anion exchange and reversed-phase, OASIS MAX solid-phase extraction (SPE) cartridges. Analytes were determined by liquid chromatography coupled to tandem mass spectrometry using atmospheric pressure electrospray ionization (LC-ESI-MS/MS). Parameters affecting the chromatographic determination and the extraction-purification processes were thoroughly investigated. Under optimized conditions, 10 mL of wine were firstly diluted 1:1 with ultrapure water and then passed through the mixed-mode SPE cartridge at a flow of ca. 5 mLmin(-1). After a washing step with 5 mL of an aqueous NH(4)OH solution (5%, w:v), analytes were recovered with just 1 mL of methanol and injected in the LC-MS/MS system without any additional purification. The selective extraction process avoided significant changes in the ionization efficiency for red and white wine extracts in comparison with pure standards in methanol. Performance of the method was good in terms of precision (RSDs<11%) and accuracy (absolute recoveries>72%, determined against pure standards in methanol) reporting method LOQs in the range of 0.01-0.79 ngmL(-1) for target compounds, which are far below the EU maxima residue levels (MRLs) for fungicides in vinification grapes and wine. Several commercial wines from different geographic areas in Spain were analyzed. In most samples, metalaxyl-M and azoxystrobin were found at concentrations up to several ngmL(-1). PMID:20971470

  15. Quantitative determination of trimebutine maleate and its three metabolites in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Hongyun; Zhou, Hui; Horimoto, Shingo; Jiang, Ji; Mayumi, Tsuyoshi; Hu, Pei

    2002-11-01

    A sensitive and selective HPLC-MS-MS method was developed for the determination of trimebutine maleate (TM) and its major metabolites N-monodemethyltrimebutine (TM-MPB), N-didemethyltrimebutine (APB) and 3,4,5-trimethoxybenzoic acid (TMBA) in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction and chromatographed on a YMC J'sphere C(18) column. The mobile phase consisted of 2 mM ammonium acetate buffer (pH 6.5)-methanol (20:80, v/v), and at a flow-rate of 0.2 ml/min. Detection was carried out on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring (MRM) mode using positive-negative switching electrospray ionization (ESI). The method was validated over the concentration range of 1-100 ng/ml for trimebutine maleate and APB, 1-500 ng/ml for MPB, and 50-10,000 ng/ml for TMBA. Inter- and intra-day precision (RSD%) for trimebutine maleate and its three metabolites were all within +/-15% and the accuracy was within 85-115%. The limit of quantitation was 1 ng/ml for trimebutine maleate, TM-MPB and APB, and 50 ng/ml for TMBA. The extraction recovery was on average 58.2% for trimebutine maleate, 69.6% for MPB, 51.2% for APB and 62.5% for TMBA. The method was applied to the pharmacokinetic study of trimebutine maleate and its metabolites in healthy Chinese volunteers. PMID:12361732

  16. Determination of phentermine, N-hydroxyphentermine and mephentermine in urine using dilute and shoot liquid chromatography-tandem mass spectrometry.

    PubMed

    Choi, Yun Jeong; Sim, Arum; Kim, Min Kyung; Suh, Sunglll; In, Moon Kyo; Kim, Jin Young

    2016-09-01

    Nonmedical use of prescription stimulants such as phentermine (PT) has been regulated by law enforcement authorities due to its euphorigenic and relaxing effects. Due to high potential for its abuse, reliable analytical methods were required to detect and identify PT and its metabolite in biological samples. Thus a dilute and shoot liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for simultaneous determination of PT, N-hydroxyphentermine (NHOPT) and mephentermine (MPT) in urine. A 5μL aliquot of diluted urine was injected into the LC-MS/MS system. Chromatographic separation was performed by reversed-phase C18 column with gradient elution for all analytes within 5min. Identification and quantification were based on multiple reaction monitoring (MRM) detection. Linear least-squares regression with a 1/x(2) weighting factor was used to generate a calibration curve and the assay was linear from 50 to 15000ng/mL (PT and MPT) and 5 to 750ng/mL (NHOPT). The intra- and inter-day precisions were within 8.9% while the intra- and inter-day accuracies ranged from -6.2% to 11.2%. The limits of quantification were 3.5ng/mL (PT), 1.5ng/mL (NHOPT) and 1.0ng/mL (MPT). Method validation requirements for selectivity, dilution integrity, matrix effect and stability were satisfied. The applicability of the developed method was examined by analyzing urine samples from drug abusers. PMID:27398632

  17. Simultaneous determination of opiates, methadone, buprenorphine and metabolites in human urine by superficially porous liquid chromatography tandem mass spectrometry.

    PubMed

    Lin, Huei-Ru; Chen, Chin-Lun; Huang, Chieh-Liang; Chen, Shao-Tsu; Lua, Ahai-Chuang

    2013-04-15

    For monitoring compliance of methadone or buprenorphine maintenance patient, a method for the simultaneous determination of methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), buprenorphine, norbuprenorphine, opiates (morphine, codeine, 6-monoacetylmorphine) in urine by superficially porous liquid chromatography tandem mass spectrometry was developed and validated. After enzyme digestion and liquid-liquid extraction, reverse-phase separation was achieved in 5.2 min and quantification was performed by multiple reaction monitoring. Chromatographic separation was performed at 40 °C on a reversed phase Poroshell column with gradient elution. The mobile phase consisted of water and methanol, each containing 0.1% formic acid, at a flow rate of 0.32 mL/min. Intra-day and inter-day precision were less than 12.1% and accuracy was between -9.8% and 13.7%. Extraction efficiencies were more than 68%. Although ion suppression was detected, deuterated internal standards compensated for these effects. Carryover was minimal, less than 0.20%. All analytes were stable at room temperature for 16 h, 4 °C for 72 h, and after three freeze-thaw cycles. The assay also fulfilled compound identification criteria in accordance with the European Commission Decision 2002/657/EC. We analyzed 62 urine samples from patients received maintenance therapy and found that 54.8% of the patient samples tested were detected for morphine, codeine, or 6-monoacetylmorphine. This method provides a reliable and simultaneous quantification of opiates, maintenance drugs, and their metabolites in urine samples. It facilitates the routine monitoring in individuals prescribed the drug to ensure compliance and help therapeutic process. PMID:23507455

  18. Assessment of tandem mass spectrometry and high-resolution mass spectrometry for the analysis of bupivacaine in plasma.

    PubMed

    Gaudette, Fleur; Benito, Javier; Steagall, Paulo; Beaudry, Francis

    2015-11-01

    Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. They provide substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected reaction monitoring allows targeted assay development but datasets generated contain very limited information. Data mining and analysis of nontargeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study were to test method precision and accuracy, to statistically compare bupivacaine drug concentration in real study samples and to verify if high-resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy ranged from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods revealed a coefficient of determination (R(2)) of 0.9996 and a slope of 1.02, demonstrating a very strong correlation between the two methods. Individual sample comparison showed differences from -4.5 to 1.6%, well within the accepted analytical error. Moreover, post-acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M - 56) and m/z 305.2224 ± 5 ppm (M + 16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post-acquisition analysis allowed us to produce semi-quantitative evaluations of the concentration-time profiles for bupicavaine metabolites.

  19. Global Analysis of the Membrane Subproteome of Pseudomonas aeruginosa using Liquid Chromatography-Tandem Mass Spectrometry

    SciTech Connect

    Blonder, Josip; Goshe, Michael B.; Xiao, Wenzhong; Camp, David G.; Wingerd, Mark A.; Davis, Ronald W.; Smith, Richard D.

    2004-05-30

    Pseudomonas aeruginosa is one of the most significant opportunistic bacterial pathogens in humans causing infections and premature death in patients with cystic fibrosis, AIDS, severe burns, organ transplants or cancer. Liquid chromatography coupled online with tandem mass spectrometry (LC-MS/MS) was used for the large-scale proteomic analysis of the P. aeruginosa membrane subproteome. Concomitantly, an affinity labeling technique, using iodoacetyl-PEO biotin to tag cysteinyl-containing proteins, permitted the enrichment and detection of lower abundance membrane proteins. The application of these approaches resulted in the identification of 786 proteins. A total of 333 proteins (42%) had a minimum of one transmembrane domain (TMD; ranging from 1 to 14) and 195 proteins were classified as hydrophobic based on their positive GRAVY values (ranging from 0.01 to 1.32). Key integral inner and outer membrane proteins involved in adaptation and antibiotic resistance were conclusively identified, including the detection of 53% of all predicted opr-type porins (outer integral membrane proteins) and all the components of the mexA-mexB-oprM transmembrane protein complex. This work represents the most comprehensive qualitative proteomic analysis of the membrane subproteome of P. aeruginosa and for prokaryotes in general to date.

  20. Proteomic analysis of endodontic infections by liquid chromatography–tandem mass spectrometry

    PubMed Central

    Nandakumar, R.; Madayiputhiya, N.; Fouad, A.F.

    2009-01-01

    Introduction Endodontic infections are very prevalent and have a polymicrobial etiology characterized by complex interrelationships between endodontic microorganisms and the host defenses. Proteomic analysis of endodontic infections can provide global insights into the invasion, pathogenicity mechanisms, and multifactorial interactions existing between root canal bacteria and the host in the initiation and progression of apical periodontitis. The purpose of this study was to apply proteomic techniques such as liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the identification of proteins of bacterial origin present in endodontic infections. Methods Endodontic specimens were aseptically obtained from seven patients with root canal infections. Protein mixtures were subjected to tryptic in-solution digestion and analysed by reverse-phase nano-LC–MS/MS followed by a database search. Results Proteins, mainly of cell wall or membrane origin, from endodontic bacteria especially Enterococcus faecalis, Enterococcus faecium, Porphyromonas gingivalis, Fusobacterium nucleatum, and Treponema denticola were identified from all the samples tested. Identified proteins included adhesins, autolysins, proteases, virulence factors, and antibiotic-resistance proteins. Conclusions LC–MS/MS offers a sensitive analytical platform to study the disease processes in the root canal environment. The array of proteins expressed in endodontic infections reflects the complex microbial presence and highlights the bacterial species involved in the inflammatory process. PMID:19572900

  1. Quantification of regional DNA methylation by liquid chromatography/tandem mass spectrometry.

    PubMed

    Liu, Zhongfa; Wu, Jiejun; Xie, Zhiliang; Liu, Shujun; Fan-Havard, Patty; Huang, Tim H-M; Plass, Christoph; Marcucci, Guido; Chan, Kenneth K

    2009-08-15

    Promoter hypermethylation-associated tumor suppressor gene (TSG) silencing has been explored as a therapeutic target for hypomethylating agents. Promoter methylation change may serve as a pharmacodynamic endpoint for evaluation of the efficacy of these agents and predict the patient's clinical response. Here a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been developed for quantitative regional DNA methylation analysis using the molar ratio of 5-methyl-2'-deoxycytidine (5mdC) to 2'-deoxycytidine (2dC) in the enzymatic hydrolysate of fully methylated bisulfite-converted polymerase chain reaction (PCR) amplicons as the methylation indicator. The assay can differentiate 5% of promoter methylation level with an intraday precision ranging from 3 to 16% using two TSGs: HIN-1 and RASSF1A. This method was applied to characterize decitabine-induced promoter DNA methylation changes of these two TSGs in a breast cancer MCF-7 cell line. Promoter methylation of these TSGs was found to decrease in a dose-dependent manner. Correspondingly, the expression of these TSGs was enhanced. The sensitivity and reproducibility of the method make it a valuable tool for specific gene methylation analysis that could aid characterization of hypomethylating activity on specific genes by hypomethylating agents in a clinical setting.

  2. [Determination of endogenous anabolic steroids in hair using gas chromatography-tandem mass spectrometry].

    PubMed

    Shen, Min; Xiang, Ping; Shen, Baohua; Wang, Mengye

    2008-07-01

    A method of gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the simultaneous identification and quantification of five endogenous anabolic steroids (testosterone, epitestosterone, androsterone, etiocholanolone, dehydroepiandrosterone) in hair. After alkaline hydrolysis, the hair sample was extracted with diethyl ether, derivatized with a derivatization reagent (N-methyl-N-trimethylsilyl-trifluoroacetamid/iodotrime-thyisilane/DL-dithiothreitol, 1000:5:5, v/v/w) and detected using GC-MS/MS in the multiple-reaction monitoring mode. The one precursor/two product ion transitions for each anabolic steroids were monitored. The limits of detection for five endogenous anabolic steroids were in the range of 0.1 - 0.2 pg/mg. All analytes showed good linearity and the extraction recoveries were 74.6% - 104.5%. The inter-day and intra-day relative standard deviations (RSD) were less than 17.5%. This method has been applied to the analysis of testosterone, epitestosterone, androsterone, etiocholanolone, dehydroepiandrosterone in 80 Chinese hair samples. These data are the suitable references and the basis for the interpretation of the results from endogenous steroids abuse.

  3. [Determination of clavulanic acid residue in milk by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Yang, Gang; Huang, Xianhui; Guo, Chunna; Fang, Qiuhua; He, Limin

    2012-06-01

    An analytical method was developed for the determination of clavulanic acid (CLAV) in milk by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). A 2 g milk sample was deproteinized by ethanol. The supernatant was transferred into a pear-shaped bottle to be evaporated to about 0.5 mL, and the residue was dissolved with ammonium acetate solution. The sample was determined by HPLC-MS/MS after the purification. The chromatographic separation was achieved on a Luna 5u C8 column using 0.1% formic acid in water and acetonitrile as mobile phases with gradient elution. The identification of CLAV was carried out by MS/MS equipped with electrospray ionization in negative scanning and multiple reaction monitoring (MRM) modes. Matrix-matched calibration standard was used for the quantification. The calibration curve showed perfect linear in the range of 10 - 400 microg/kg with the correlation coefficient of 0.999. The limit of detection (LOD, S/N > or = 3) was 10 microg/kg in milk, and the limit of quantification (LOQ, S/N > or = 10) was 20 microg/kg. The mean recoveries varied from 80.00% to 91.25% at the four spiked levels of LOQ, 1/2MRL (the maximum residue limit), MRL, and 2MRL with the relative standard deviations of 5.60% -8.77%. In conclusion, the established method can be applied for the determination of CLAV residues in milk.

  4. Effective Leveraging of Targeted Search Spaces for Improving Peptide Identification in Tandem Mass Spectrometry Based Proteomics.

    PubMed

    Shanmugam, Avinash K; Nesvizhskii, Alexey I

    2015-12-01

    In shotgun proteomics, peptides are typically identified using database searching, which involves scoring acquired tandem mass spectra against peptides derived from standard protein sequence databases such as Uniprot, Refseq, or Ensembl. In this strategy, the sensitivity of peptide identification is known to be affected by the size of the search space. Therefore, creating a targeted sequence database containing only peptides likely to be present in the analyzed sample can be a useful technique for improving the sensitivity of peptide identification. In this study, we describe how targeted peptide databases can be created based on the frequency of identification in the global proteome machine database (GPMDB), the largest publicly available repository of peptide and protein identification data. We demonstrate that targeted peptide databases can be easily integrated into existing proteome analysis workflows and describe a computational strategy for minimizing any loss of peptide identifications arising from potential search space incompleteness in the targeted search spaces. We demonstrate the performance of our workflow using several data sets of varying size and sample complexity.

  5. Newborn screening with tandem mass spectrometry: 12 months' experience in NSW Australia.

    PubMed

    Wiley, V; Carpenter, K; Wilcken, B

    1999-12-01

    Since 1998, the NSW Newborn Screening Program has used electrospray tandem mass spectrometry (MS/MS) to analyse samples from all babies born in NSW and the ACT (approximately 95000 per year) for selected amino acids and acylcarnitines. The software rules editor initially interprets all results where ratio of analyte to internal standard is modified by input from the external standard curves per analyte. The numerical results are then downloaded to the NSW Newborn Screening database, which provides automatic, analyte specific follow-up test cascade. We have analysed samples from 137 120 consecutive newborns received by the program, requested repeat samples from 122 babies, and found abnormal levels in 17 babies with phenylketonuria, 1 tetrahydrobiopterin deficiency, 3 hyperphenylalaninaemia, 1 maple syrup urine disease, 1 tyrosinaemia type II, 1 congenital lactic acidosis, 2 medium-chain acyl CoA dehydrogenase deficiency, 1 short-chain acyl CoA dehydrogenase deficiency, 1 beta-ketothiolase deficiency, 2 vitamin B12 deficient babies of vegan mothers and 1 glutaric aciduria type I. Using population data plus that obtained from retrospective samples with proven disorders we have established cut-off levels for each analyte tested. This coupled with the ability of the database to provide ratios of various analytes gives excellent screening specificity and sensitivity for the detection of at least 40 rare inborn errors of metabolism.

  6. Partial enzymatic elimination and quantification of sarcosine from alanine using liquid chromatography-tandem mass spectrometry.

    PubMed

    Burton, Casey; Gamagedara, Sanjeewa; Ma, Yinfa

    2013-04-01

    Since sarcosine and D,L-alanine co-elute on reversed-phase high-performance liquid chromatography (HPLC) columns and the tandem mass spectrometer cannot differentiate them due to equivalent parent and fragment ions, derivatization is often required for analysis of sarcosine in LC/MS systems. This study offers an alternative to derivatization by employing partial elimination of sarcosine by enzymatic oxidation. The decrease in apparent concentration from the traditionally merged sarcosine-alanine peak associated with the enzymatic elimination has been shown to be proportional to the total sarcosine present (R(2) = 0.9999), allowing for determinations of urinary sarcosine. Sarcosine oxidase was shown to eliminate only sarcosine in the presence of D,L-alanine, and was consequently used as the selective enzyme. This newly developed technique has a method detection limit of 1 μg/L (parts per billion) with a linear range of 3 ppb-1 mg/L (parts per million) in urine matrices. The method was further validated through spiked recoveries of real urine samples, as well as the analysis of 35 real urine samples. The average recoveries for low, middle, and high sarcosine concentration spikes were 111.7, 90.8, and 90.1 %, respectively. In conclusion, this simple enzymatic approach coupled with HPLC/MS/MS is able to resolve sarcosine from D,L-alanine leading to underivatized quantification of sarcosine.

  7. [Determination of 132 pesticide residues in tobacco by gas chromatography-tandem mass spectrometry].

    PubMed

    Chen, Xiaoshui; Bian, Zhaoyang; Tang, Gangling; Hu, Qingyuan

    2012-10-01

    A simple method for the determination of 132 pesticide residues in tobacco by gas chromatography-triple quadrupole tandem mass spectrometry (GC-MS/MS) was established. The influences of different extraction solvents, different buffer systems and different purifying agents on the recoveries of pesticides were investigated. The tobacco sample was extracted with acetonitrile, then cleaned up by the mixed sorbents of primary secondary amine (PSA) and octadecylsilane (C18E). After dried by nitrogen, the extract residue was reconstituted with n-hexane-acetone (9:1, v/v). GC-MS/MS in multi-reaction monitoring (MRM) mode was used as the detection method and triphenyl phosphate (TPP) as the internal standard. All of the 132 pesticides had good linear relationships (r2 > 0.99) between 20 microg/kg and 2 000 microg/kg. At the three spiked levels of 50, 200 and 500 microg/kg in the tobacco extract, the average recoveries of all the pesticides were in the range of 68.10% to 123.15% except for mirex and hexachlorobenzene; moreover, the relative standard deviations (RSDs) of them were between 1.79% and 19.88%. We participated in the CORESTA (Cooperation Centre for Scientific Research Relative to Tobacco) 2012's co-experiment. The results of our method and the existed standard methods had good consistency. The accurate, reliable and sensitive method can be applied to the determination of the 132 pesticide residues in tobacco for rapid screening and quantitative analysis.

  8. Investigation of the biotransformation of osthole by liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Jie; Chan, Wan

    2013-02-23

    Osthole is an active ingredient and one of the major coumarin compounds that were identified in the genus Cnidium moonnieri (L.) Cussion, the fruit of which was used as traditional Chinese medicine to treat male impotence, ringworm infection and blood stasis conventionally. Recent studies revealed that osthole has diverse pharmacological effects, such as improving male sexual dysfunction, anti-diabetes, and anti-hypertentions. The inhibition of thrombosis and platelet aggregation and protection of central nerve were also observed. On the other hand, the metabolism of osthole has not yet been investigated thoroughly. Herein the biotransformation of osthole in rat was investigated after oral administration of osthole by using efficient and sensitive ultra-performance liquid chromatography-tandem quadrupole-time of flight mass spectrometry (UPLC-QTOF/MS). Eighteen osthole metabolites and the parent drug were detected and identified in rat urine. Fourteen metabolites of osthole were identified and characterized for the first time. Structures of metabolites of osthole were elucidated by comparing fragment pattern under MS/MS scan and change of molecular weight with those of osthole. The main phase I metabolic pathways were summed as 7-demethylation, 8-dehydrogenation, hydroxylation on coumarin and 3,4-epoxide. Sulfate conjugates were detected as phase II metabolites of osthole. PMID:23245246

  9. Determination of 76 pharmaceutical drugs by liquid chromatography-tandem mass spectrometry in slaughterhouse wastewater.

    PubMed

    Shao, Bing; Chen, Dong; Zhang, Jing; Wu, Yongning; Sun, Chengjun

    2009-11-20

    A multi-residue method for the analysis of 76 pharmaceutical agents of nine classes of drugs (tetracyclines, macrolides, fluoroquinolones, beta-agonists, beta-blockers, diuretics, sedatives, sulfonamides and chloramphenicol) in slaughterhouse wastewater and a receiving river is presented. After simultaneous extraction with an Oasis HLB solid-phase extraction (SPE) cartridge and further purification using an amino SPE cartridge, analytes were detected by liquid chromatography-electrospray ionization-tandem mass spectrometry in positive or negative ion mode. Standard addition was used for quantification to overcome unavoidable matrix effects during ESI-MS analysis. Recoveries for most analytes based on matrix-matched calibration in different test matrices were >60%. The method quantification limits of 76 pharmaceuticals were in the range 0.2-30 ng/L. Nineteen compounds of 76 drugs were found in raw and treated slaughterhouse wastewater from four main slaughterhouses in Beijing. Sulfanamides (sulfanilamide, sulfameter), fluoroquenones (ofloxacin, pefloxacin, norfloxacin, ciprofloxacin, enrofloxacin), tetracyclines (tetracycline, oxytetracycline) and macrolides (kitasamycin, tylosin, erythromycin) were most frequently detected, with the highest levels up to approximately 3 microg/L in slaughterhouse wastewater and approximately 1 microg/L in treated wastewater. Illicit drugs for animal feeding such as clenbuterol and diazepam were commonly detected in slaughterhouse wastewater. These analytes were also observed in a river receiving slaughterhouse wastewater, with a highest level of up to 0.2 microg/L.

  10. Speeding up tandem mass spectrometry-based database searching by longest common prefix

    PubMed Central

    2010-01-01

    Background Tandem mass spectrometry-based database searching has become an important technology for peptide and protein identification. One of the key challenges in database searching is the remarkable increase in computational demand, brought about by the expansion of protein databases, semi- or non-specific enzymatic digestion, post-translational modifications and other factors. Some software tools choose peptide indexing to accelerate processing. However, peptide indexing requires a large amount of time and space for construction, especially for the non-specific digestion. Additionally, it is not flexible to use. Results We developed an algorithm based on the longest common prefix (ABLCP) to efficiently organize a protein sequence database. The longest common prefix is a data structure that is always coupled to the suffix array. It eliminates redundant candidate peptides in databases and reduces the corresponding peptide-spectrum matching times, thereby decreasing the identification time. This algorithm is based on the property of the longest common prefix. Even enzymatic digestion poses a challenge to this property, but some adjustments can be made to this algorithm to ensure that no candidate peptides are omitted. Compared with peptide indexing, ABLCP requires much less time and space for construction and is subject to fewer restrictions. Conclusions The ABLCP algorithm can help to improve data analysis efficiency. A software tool implementing this algorithm is available at http://pfind.ict.ac.cn/pfind2dot5/index.htm PMID:21108792

  11. Enantiomeric analysis of polycyclic musks in water by chiral gas chromatography-tandem mass spectrometry.

    PubMed

    Wang, Lili; McDonald, James A; Khan, Stuart J

    2013-08-16

    Galaxolide (HHCB), tonalide (AHTN), phantolide (AHDI), traseolide (ATII) and cashmeran (DPMI) are synthetic polycyclic musks (PCMs). They are all commonly used in fragrance industries as racemic mixtures. A sensitive and robust enantioselective analytical method was developed to facilitate measurement of these chemicals in wastewater and environmental samples. The method is based on gas chromatography with tandem mass spectrometry (GC-MS/MS). Enantioseparation was assessed using four commercially available chiral capillary columns. Optimised resolution was achieved using a dual-column configuration of a chiral heptakis(2,3- di-O-methyl-6-O-t-butyl dimethylsilyl)-β-cyclodextrin column combined with a (non-chiral) HP-5MS column. This configuration was demonstrated to be capable of effectively resolving all commercially manufactured enantiomers of these five PCMs. Method detection limits for single enantiomers in drinking water and surface water range between 1.01 and 2.39ngL(-1). Full validation of the application of this method in these aqueous matrices is provided.

  12. Determination of benzophenones in human placental tissue samples by liquid chromatography-tandem mass spectrometry.

    PubMed

    Vela-Soria, F; Jiménez-Díaz, I; Rodríguez-Gómez, R; Zafra-Gómez, A; Ballesteros, O; Navalón, A; Vílchez, J L; Fernández, M F; Olea, N

    2011-09-30

    Benzophenones (BPs) are a family of compounds widely used to protect the skin and hair from UV irradiation. Despite human exposure to BPs through dermal application of products containing sunscreen agents and the increasing evidence that BPs are able to interfere with endocrine systems, few studies have examined the occurrence of BPs in humans. In this work, we propose a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine six BPs, namely, benzophenone-1 (BP-1), benzophenone-2 (BP-2), benzophenone-3 (BP-3), benzophenone-6 (BP-6), benzophenone-8 (BP-8) and 4-hydroxybenzophenone (4-OH-BP) in human placental tissue samples. The method involves an extraction step of the analytes from the samples using ethyl acetate, followed by a clean-up step using centrifugation prior to their quantification by LC-MS/MS using an atmospheric pressure chemical ionization (APCI) interface in the positive mode. Benzophenone-d(10) (BP-d(10)) was used as surrogate. Found detection limits (LOD) ranged from 0.07 to 0.3 ng g(-1) and quantification limits (LOQ) from 0.3 to 1.0 ng g(-1), while inter- and intra-day variability was under 5%. The method was validated using standard addition calibration and a recovery assay. Recovery rates for spiked samples ranged from 98 to 104%. This method was satisfactorily applied for the determination of BPs in 16 placental tissue samples collected from women who live in Granada (Spain).

  13. Identification of Microorganisms by High Resolution Tandem Mass Spectrometry with Accurate Statistical Significance.

    PubMed

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y; Drake, Steven K; Gucek, Marjan; Suffredini, Anthony F; Sacks, David B; Yu, Yi-Kuo

    2016-02-01

    Correct and rapid identification of microorganisms is the key to the success of many important applications in health and safety, including, but not limited to, infection treatment, food safety, and biodefense. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is challenging correct microbial identification because of the large number of choices present. To properly disentangle candidate microbes, one needs to go beyond apparent morphology or simple 'fingerprinting'; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptidome profiles of microbes to better separate them and by designing an analysis method that yields accurate statistical significance. Here, we present an analysis pipeline that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using MS/MS data of 81 samples, each composed of a single known microorganism, that the proposed pipeline can correctly identify microorganisms at least at the genus and species levels. We have also shown that the proposed pipeline computes accurate statistical significances, i.e., E-values for identified peptides and unified E-values for identified microorganisms. The proposed analysis pipeline has been implemented in MiCId, a freely available software for Microorganism Classification and Identification. MiCId is available for download at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html . Graphical Abstract ᅟ.

  14. Identification of Microorganisms by High Resolution Tandem Mass Spectrometry with Accurate Statistical Significance

    NASA Astrophysics Data System (ADS)

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y.; Drake, Steven K.; Gucek, Marjan; Suffredini, Anthony F.; Sacks, David B.; Yu, Yi-Kuo

    2016-02-01

    Correct and rapid identification of microorganisms is the key to the success of many important applications in health and safety, including, but not limited to, infection treatment, food safety, and biodefense. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is challenging correct microbial identification because of the large number of choices present. To properly disentangle candidate microbes, one needs to go beyond apparent morphology or simple `fingerprinting'; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptidome profiles of microbes to better separate them and by designing an analysis method that yields accurate statistical significance. Here, we present an analysis pipeline that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using MS/MS data of 81 samples, each composed of a single known microorganism, that the proposed pipeline can correctly identify microorganisms at least at the genus and species levels. We have also shown that the proposed pipeline computes accurate statistical significances, i.e., E-values for identified peptides and unified E-values for identified microorganisms. The proposed analysis pipeline has been implemented in MiCId, a freely available software for Microorganism Classification and Identification. MiCId is available for download at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html.

  15. [Analysis of trichothecenes in barley tea and beer by liquid chromatography/tandem mass spectrometry].

    PubMed

    Suga, Keiko; Mochizuki, Naoki; Harayama, Koichi; Yamashita, Hiroshi

    2004-12-01

    A simple method for analysis of trichothecenes [Type A: diacetoxyscirpenol, neosolaniol, HT-2 toxin, and T-2 toxin, Type B: deoxynivalenol, nivalenol, fusarenon-X, 3-acetyldeoxynivalenol, 15-acetyldeoxynivarenol] in barley tea and beer using liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed. Trichothecenes were extracted with ethyl acetate-methanol (19:1). The solvent was evaporated to dryness and the residue was dissolved in water-methanol (3:1) for injection into the LC/MS/MS. The LC separation was performed with an octadecylated silica column at a flow-rate of 0.2 mL/min, using a mobile phase consisting of water, methanol and acetonitrile. MS/MS was used in multiple reaction monitoring, employing electrospray ionization (ESI-MRM). The recoveries of trichothecenes from drinks at 1 microg/L (Type A) and 10 microg/L (Type B) were 52.5-115.2% (barley tea) and 68.1-127.5% (beer). Five barley tea and ten beer samples were analyzed by this method. Trichothecenes were not detected in them. This method may have applications in quality assurance.

  16. Glycerophospholipid analysis of Eastern red bat (Lasiurus borealis) hair by electrospray ionization tandem mass spectrometry.

    PubMed

    Pannkuk, Evan L; McGuire, Liam P; Gilmore, David F; Savary, Brett J; Risch, Thomas S

    2014-03-01

    Pilosebaceous units found in the mammalian integument are composed of a hair follicle, the proximal portion of the hair shaft, a sebaceous gland, and the erector pili muscle. Pilosebaceous units release protective oils, or sebum, by holocrine secretion onto skin and hair through rupturing of sebocytes. Sebum is composed largely of polar and neutral lipids including glycerolipids, free fatty acids, sterols, wax esters, sterol esters, and squalene. In addition to these lipid classes, there is a small proportion of ionic/anionic glycerophospholipids (GPs). Composition of GPs on hair is rarely addressed despite their broad biological activities as signaling molecules and membrane stability. Furthermore, knowledge on GP composition in bats is lacking. Bat GP composition is important to document due to GP roles ranging from decreasing drag during migration to interaction with the integumentary microbiome. In this study, we analyzed GP molecular composition with liquid chromatography electrospray ionization tandem mass spectrometry and compared GP content to previous literature. A total of 152 GPs were detected. Broad GP classes identified include lysophosphatidylcholine, phosphatidylcholine (PC), lysophosphatidylethanolamine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidic acid, and phosphatidylglycerol, with PC being the most abundant class. The acyl components were consistent with fatty acid methyl esters and triacylglyceride moieties found in Eastern red bat sebum. Glycerophospholipid proportions of the hair surface were different from a previous study on bat lung surfactants. This study determined the broad class and molecular species of bat sebum GPs that may be used in future ecological studies in vespertilionid bats. PMID:24532214

  17. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  18. Determination of melatonin in Acyrthosiphon pisum aphids by liquid chromatography-tandem mass spectrometry.

    PubMed

    Escrivá, Laura; Manyes, Lara; Barberà, Miquel; Martínez-Torres, David; Meca, Guiseppe

    2016-03-01

    Melatonin is a hormone mainly involved in the regulation of circadian and seasonal rhythms in both invertebrates and vertebrates. Despite the identification of melatonin in many insects, its involvement in the insect seasonal response remains unclear. A liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for melatonin analysis in aphids (Acyrthosiphon pisum) for the first time. After comparing two different procedures and five extraction solvents, a sample preparation procedure with a mixture of methanol/water (50:50) was selected for melatonin extraction. The method was validated by analyzing melatonin recovery at three spiked concentrations (5, 50 and 100 pg/mg) and showed satisfactory recoveries (75-110%), and good repeatability, expressed as relative standard deviation (<10%). Limits of detection (LOD) and quantitation (LOQ) were 1 pg/mg and 5 pg/mg, respectively. Eight concentration levels were used for constructing the calibration curves which showed good linearity between LOQ and 200 times LOQ. The validated method was successfully applied to 26 aphid samples demonstrating its usefulness for melatonin determination in insects. This is -to our knowledge- the first identification of melatonin in aphids by LC-MS/MS.

  19. Structural elucidation of isocyanate-peptide adducts using tandem mass spectrometry.

    PubMed

    Hettick, Justin M; Ruwona, Tinashe B; Siegel, Paul D

    2009-08-01

    Diisocyanates are highly reactive chemical compounds widely used in the manufacture of polyurethanes. Although diisocyanates have been identified as causative agents of allergic respiratory diseases, the specific mechanism by which these diseases occur is largely unknown. To better understand the chemical species produced when isocyanates are reacted with model peptides, tandem mass spectrometry was employed to unambiguously identify the binding site of four commercially-relevant isocyanates on model peptides. In each case, the isocyanates react preferentially with the N-terminus of the peptide. No evidence of side-chain/isocyanate adduct formation exclusive of the N-terminus was observed. However, significant intra-molecular diisocyanate crosslinking was observed between the N-terminal amine and a side-chain amine of arginine, when Arg was located within two residues of the N-terminus. Addition of multiple isocyanates to the peptide occurs via polymerization of the isocyanate at the N-terminus, rather than via addition of multiple isocyanate molecules to varied residues within the peptide. The direct observation of isocyanate binding to the N-terminus of peptides under these experimental conditions is in good agreement with previous studies on the relative reaction rate of isocyanate with amino acid functional groups.

  20. Simultaneous determination of chlorpheniramine and pseudoephedrine in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Chen, Xiaoyan; Zhang, Yong; Zhong, Dafang

    2004-05-01

    A sensitive and specific procedure for simultaneous quantitation of chlorpheniramine and pseudoephedrine in human plasma has been developed and validated. Analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column (250 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an atmospheric pressure chemical ionization interface. Diphenhydramine was used as the internal standard. The method has a lower limit of quantitation of 0.2 and 2.0 ng/mL for chlorpheniramine and pseudoephedrine, respectively. The intra- and inter-day relative standard deviation, calculated from quality control (QC) samples were below 4.3% for chlorpheniramine and below 9.5% for pseudoephedrine. The inter-day relative error as determined from QC samples was within 4.7% for each analyte. The overall extraction recoveries of chlorpheniramine and pseudoephedrine were 77 and 61% on average, respectively. The method was successfully applied to pharmaockinetic study of chlorpheniramine and pseudoephedrine in volunteers receiving formulations containing 4 mg of chlorpheniramine maleate and 60 mg of pseudoephedrine hydrochloride.

  1. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    PubMed

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  2. Antibiotic Toxicity and Absorption in Zebrafish Using Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Zhang, Fan; Qin, Wei; Zhang, Jing-Pu; Hu, Chang-Qin

    2015-01-01

    Evaluation of drug toxicity is necessary for drug safety, but in vivo drug absorption is varied; therefore, a rapid, sensitive and reliable method for measuring drugs is needed. Zebrafish are acceptable drug toxicity screening models; we used these animals with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in a multiple reaction monitoring mode to quantify drug uptake in zebrafish to better estimate drug toxicity. Analytes were recovered from zebrafish homogenate by collecting supernatant. Measurements were confirmed for drugs in the range of 10–1,000 ng/mL. Four antibiotics with different polarities were tested to explore any correlation of drug polarity, absorption, and toxicity. Zebrafish at 3 days post-fertilization (dpf) absorbed more drug than those at 6 h post-fertilization (hpf), and different developmental periods appeared to be differentially sensitive to the same compound. By observing abnormal embryos and LD50 values, zebrafish embryos at 6 hpf were considered to be suitable for evaluating embryotoxicity. Also, larvae at 3 dpf were adapted to measure acute drug toxicity in adult mammals. Thus, we can exploit zebrafish to study drug toxicity and can reliably quantify drug uptake with LC-MS/MS. This approach will be helpful for future studies of toxicology in zebrafish. PMID:25938774

  3. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    PubMed

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics. PMID:26182469

  4. Direct Tandem Mass Spectrometric Profiling of Sulfatides in Dry Urinary Samples for Screening of Metachromatic Leukodystrophy

    PubMed Central

    Kuchař, Ladislav; Asfaw, Befekadu; Poupětová, Helena; Honzíková, Jitka; Tureček, František; Ledvinová, Jana

    2013-01-01

    Background Prediagnostic steps in suspected metachromatic leukodystrophy (MLD) rely onclinical chemical methods other than enzyme assays. We report a new diagnostic method which evaluates changes in the spectrum of molecular types of sulfatides (3-O-sulfogalactosyl ceramides) in MLD urine. Methods The procedure allows isolation of urinary sulfatides by solid-phase extraction on DEAE-cellulose membranes, transportation of a dry membrane followed by elution and tandem mass spectrometry (MS/MS) analysis in the clinical laboratory. Major sulfatide isoforms are normalized to the least variable component of the spectrum, which is the indigenous C18:0 isoform. This procedure does not require the use of specific internal standards and minimizes errors caused by sample preparation and measurement. Results Urinary sulfatides were analyzed in a set of 21 samples from patients affected by sulfatidosis. The combined abundance of the five most elevated isoforms, C22:0, C22:0-OH, C24:0, C24:1-OH, and C24:0-OH sulfatides, was found to give the greatest distinction between MLD-affected patients and a control group. Conclusions The method avoids transportation of liquid urine samples and generates stable membrane-bound sulfatide samples that can be stored at ambient temperature. MS/MS sulfatide profiling targeted on the most MLD-representative isoforms is simple with robust results and is suitable for screening. PMID:23838369

  5. Formation of prostamides from anandamide in FAAH knockout mice analyzed by HPLC with tandem mass spectrometry.

    PubMed

    Weber, Allan; Ni, Jinsong; Ling, Kah-Hiing John; Acheampong, Andrew; Tang-Liu, Diane D-S; Burk, Robert; Cravatt, Benjamin F; Woodward, David

    2004-04-01

    We investigated the formation of PGF(2alpha) 1-ethanolamide, PGE(2) 1-ethanolamide, and PGD(2) 1-ethanolamide (prostamides F(2alpha), E(2), and D(2), respectively) in liver, lung, kidney, and small intestine after a single intravenous bolus administration of 50 mg/kg of anandamide to normal and fatty acid amide hydrolase knockout (FAAH -/-) male mice. One group of three normal mice was not dosed (naïve) while another group of three normal mice received a bolus intravenous injection of 50 mg/kg of anandamide. Three FAAH -/- mice also received an intravenous injection of 50 mg/kg of anandamide. After 30 min, the lung, liver, kidney, and small intestine were harvested and processed by liquid-liquid extraction. The concentrations of prostamide F(2alpha), prostamide E(2), prostamide D(2), and anandamide were determined by HPLC-tandem mass spectrometry. Prostamide F(2alpha) was detected in tissues in FAAH -/- mice after administration of anandamide. Concentrations of anandamide, prostamide E(2), and prostamide D(2) in liver, kidney, lung, and small intestine were much higher in the anandamide-treated FAAH -/- mice than those of the anandamide-treated control mice. This report demonstrates that prostamides, including prostamide F(2alpha), were formed in vivo from anandamide, potentially by the cyclooxygenase-2 pathway when the competing FAAH pathway is lacking. PMID:14729864

  6. Fully automated screening of veterinary drugs in milk by turbulent flow chromatography and tandem mass spectrometry

    PubMed Central

    Stolker, Alida A. M.; Peters, Ruud J. B.; Zuiderent, Richard; DiBussolo, Joseph M.

    2010-01-01

    There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening method in routine analysis of milk samples. Eight veterinary drugs, belonging to seven different classes were selected for this study. After developing and optimising the method, parameters such as linearity, repeatability, matrix effects and carry-over were studied. The screening method was then tested in the routine analysis of 12 raw milk samples. Even without internal standards, the linearity of the method was found to be good in the concentration range of 50 to 500 µg/L. Regarding repeatability, RSDs below 12% were obtained for all analytes, with only a few exceptions. The limits of detection were between 0.1 and 5.2 µg/L, far below the maximum residue levels for milk set by the EU regulations. While matrix effects—ion suppression or enhancement—are obtained for all the analytes the method has proved to be useful for screening purposes because of its sensitivity, linearity and repeatability. Furthermore, when performing the routine analysis of the raw milk samples, no false positive or negative results were obtained. PMID:20379812

  7. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    PubMed

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100 μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0 μg/kg, 0.1-4.0 μg/kg and 1.2-3.0 μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis.

  8. Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry.

    PubMed

    Ito, Jun; Herter, Thomas; Baidoo, Edward E K; Lao, Jeemeng; Vega-Sánchez, Miguel E; Michelle Smith-Moritz, A; Adams, Paul D; Keasling, Jay D; Usadel, Björn; Petzold, Christopher J; Heazlewood, Joshua L

    2014-03-01

    Understanding the intricate metabolic processes involved in plant cell wall biosynthesis is limited by difficulties in performing sensitive quantification of many involved compounds. Hydrophilic interaction liquid chromatography is a useful technique for the analysis of hydrophilic metabolites from complex biological extracts and forms the basis of this method to quantify plant cell wall precursors. A zwitterionic silica-based stationary phase has been used to separate hydrophilic nucleotide sugars involved in cell wall biosynthesis from milligram amounts of leaf tissue. A tandem mass spectrometry operating in selected reaction monitoring mode was used to quantify nucleotide sugars. This method was highly repeatable and quantified 12 nucleotide sugars at low femtomole quantities, with linear responses up to four orders of magnitude to several 100pmol. The method was also successfully applied to the analysis of purified leaf extracts from two model plant species with variations in their cell wall sugar compositions and indicated significant differences in the levels of 6 out of 12 nucleotide sugars. The plant nucleotide sugar extraction procedure was demonstrated to have good recovery rates with minimal matrix effects. The approach results in a significant improvement in sensitivity when applied to plant samples over currently employed techniques.

  9. Axial Imidazole Binding Strengths in Porphyrinoid Cobalt(III) Complexes as Studied by Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Mishra, Ekta; Worlinsky, Jill L.; Gilbert, Thomas M.; Brückner, Christian; Ryzhov, Victor

    2012-06-01

    The Co(II) complexes of twelve meso-tetraaryl-porphyrins, -chlorins, and chlorin analogues containing non-pyrrolic heterocycles were synthesized and converted in situ to the corresponding Co(III) complexes coordinated to one or two imidazoles. Electrospray ionization tandem mass spectrometry (ESI-MS/MS) in conjunction with the energy-variable collision-induced dissociation (CID) technique was used to compare the relative gas-phase binding strength of the axially coordinated imidazoles to the octahedral and square planar Co(III) porphyrinoid complex ions. The observed binding energies of these ligands were rationalized in terms of the effects of porphyrinoid core structure and meso-substitution on the electron density on the central Co(III) centers. Some of these trends were supported by DFT-based computational studies. The study highlights to which extend porphyrins vary from chlorins and chlorin analogues in their coordination abilities and to which extraordinary degree meso-thienyl-substituents influence the electronic structure of porphyrins. The study also defines further the scope and limits CID experiments can be used to interrogate the electronic structures of metalloporphyrin complexes.

  10. Selective extraction and determination of neonicotinoid insecticides in wine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Rodríguez-Cabo, T; Casado, J; Rodríguez, I; Ramil, M; Cela, R

    2016-08-19

    A simplified, high throughput procedure for the determination of five neonicotinoid insecticides in red and white wines, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS), is presented. The effects of different experimental parameters (extraction sorbent, solvent elution and clean-up conditions) in the efficiency and the selectivity of the sample preparation process were assessed through calculation of the extraction yields and the matrix effects (MEs). Wines (10mL) were concentrated using OASIS HLB cartridges, on-line connected to Florisil clean-up cartridges, with acetonitrile serving as the elution solvent. The extract (5mLvol) was concentrated to 1mL and injected in the LC-ESI-MS/MS system. The optimized procedure provided quantitative extraction yields at the same time that the efficiency of ESI ionization remained unchanged between standards and sample extracts. Overall recoveries, calculated against authentic standards in ACN, varied between 77 and 119% and the attained limits of quantification remained below 0.2ngmL(-1). Analysis of commercial wines revealed imidacloprid residues in more than 50% of processed samples, with a maximum level of 14ngmL(-1). PMID:27425763

  11. Detection of prohibited substances by liquid chromatography tandem mass spectrometry for sports doping control.

    PubMed

    Ahrens, Brian D; Starcevic, Borislav; Butch, Anthony W

    2012-01-01

    Drug testing for sports doping control programs is extensive and includes numerous classes of banned compounds including anabolic androgenic steroids, β2-agonists, hormone antagonists and modulators, diuretics, various peptide hormones, and growth factors. During competition, additional compounds may also be prohibited such as stimulants, narcotics, cannabinoids, glucocorticosteroids, and beta-blockers depending both on the sport and level of competition. Each of these classes of compounds can contain many prohibited substances that must be identified during the testing procedure. Various methods that have been designed to detect a large number of compounds in different drug classes are highly desirable as initial screening tools. Liquid chromatography/tandem mass spectrometry (LC-MS/MS) is widely used by anti-doping testing laboratories for this purpose and several rapid methods have been described to simultaneously detect different classes of compounds. Here, we describe a simple urine sample cleanup procedure that can be used to detect numerous anabolic androgenic steroids, β2-agonists, hormone antagonists and modulators, glucocorticosteroids, and beta-blockers by LC-MS/MS.

  12. Differentiating Isobaric Steroid Hormone Metabolites Using Multi-Stage Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Tedmon, Lauren; Barnes, Jeremy S.; Nguyen, Hien P.; Schug, Kevin A.

    2013-03-01

    Steroid hormones and their metabolites are currently undergoing clinical trials as potential therapeutics for traumatic brain injury (TBI). To support this work, it is necessary to develop improved procedures for differentiating isobaric species in this compound class. Equilin sulfate (E-S), estrone sulfate (E1-S), 17α-dihydroequilin sulfate (ADHE-S), and 17β-dihydroequilin sulfate (BDHE-S) are primary constituents in hormone replacement therapies, such as Premarin, which are among pharmaceuticals being investigated for TBI treatment. The latter three compounds are isomers and can be difficult to differentiate in trace analytical determinations. In this work, a systematic study of the fragmentation of ADHE-S, BDHE-S, E1-S, and E-S under different stages of higher order tandem mass spectrometry (MSn) and variation of collision energy, allowed optimization of conditions for distinguishing the isomeric structures. For epimeric variants (e.g., ADHE-S versus BDHE-S; α- versus β-stereoisomerization in the C-17 position), differentiation was achieved at MS4 and fragmentation was demonstrated through MS5. Computational analysis was performed to further explore differences in the fragmentation pathways due to changes in stereochemistry.

  13. Evaluation of 3-methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry newborn screening.

    PubMed

    Koeberl, D D; Millington, D S; Smith, W E; Weavil, S D; Muenzer, J; McCandless, S E; Kishnani, P S; McDonald, M T; Chaing, S; Boney, A; Moore, E; Frazier, D M

    2003-01-01

    Since the addition of tandem mass spectrometry (MS/MS) to the North Carolina Newborn Screening Program, 20 infants with two consecutive elevated 3-hydroxyisovalerylcarnitine (C5OH) levels have been evaluated for evidence of inborn errors of metabolism associated with this metabolite. Ten of these 20 infants had significant concentrations of both 3-hydroxyisovaleric acid and 3-methylcrotonylglycine in their urine, suggestive of 3-methylcrotonyl-CoA carboxylase (3-MCC) deficiency. Four of these 10 were infants whose abnormal metabolites were found to be of maternal origin. Of 8 patients with probable 3-MCC deficiency, 7 have been tested and found to have the enzyme deficiency confirmed in lymphoblasts or cultured fibroblasts; one of these 7 infants had only marginally decreased 3-MCC activity in lymphocytes but deficient 3-MCC in fibroblasts. We estimate the incidence of 3-MCC deficiency at 1:64000 live births in North Carolina. We conclude that MS/MS newborn screening will detect additional inborn errors of metabolism, such as 3-MCC deficiency, not traditionally associated with newborn screening. The evaluation of newborns with two abnormally elevated C5OH levels on MS/MS newborn screening should include, at least, urine organic acid analysis by capillary GC-MS and a plasma acylcarnitine profile by MS/MS. Long-term follow-up is needed to determine the outcome of presymptomatically diagnosed patients with 3-MCC deficiency by MS/MS newborn screening.

  14. Quantification of artemisinin in human plasma using liquid chromatography coupled to tandem mass spectrometry

    PubMed Central

    Lindegardh, N.; Tarning, J.; Toi, P.V.; Hien, T.T.; Farrar, J.; Singhasivanon, P.; White, N.J.; Ashton, M.; Day, N.P.J.

    2009-01-01

    A liquid chromatographic tandem mass spectroscopy method for the quantification of artemisinin in human heparinised plasma has been developed and validated. The method uses Oasis HLB™ μ-elution solid phase extraction 96-well plates to facilitate a high throughput of 192 samples a day. Artesunate (internal standard) in a plasma–water solution was added to plasma (50 μL) before solid phase extraction. Artemisinin and its internal standard artesunate were analysed by liquid chromatography and MS/MS detection on a Hypersil Gold C18 (100 mm × 2.1 mm, 5 μm) column using a mobile phase containing acetonitrile–ammonium acetate 10 mM pH 3.5 (50:50, v/v) at a flow rate of 0.5 mL/min. The method has been validated according to published FDA guidelines and showed excellent performance. The within-day, between-day and total precisions expressed as R.S.D., were lower than 8% at all tested quality control levels including the upper and lower limit of quantification. The limit of detection was 0.257 ng/mL for artemisinin and the calibration range was 1.03–762 ng/mL using 50 μL plasma. The method was free from matrix effects as demonstrated both graphically and quantitatively. PMID:19162422

  15. Multi-detection of preservatives in cheeses by liquid chromatography-tandem mass spectrometry.

    PubMed

    Fuselli, Fabio; Guarino, Chiara; La Mantia, Alessandro; Longo, Lucia; Faberi, Angelo; Marianella, Rosa Maria

    2012-10-01

    The incorrect use of preservatives in cheeses may compromise food safety and damage consumers. According to the law, more than one preservative may be contemporarily used in cheeses. So a method for their contemporary detection may be useful for both manufacturers and control agencies quality control. In this research a liquid chromatography-tandem mass spectrometric with electrospray ionization method for the multi-determination of seven preservatives (benzoic acid, citric acid, hexamethylenetetramine, lysozyme, natamycin, nisin and sorbic acid) in cheese was developed. The preservatives were contemporarily extracted from cheese by a single procedure, and analyzed by RP-LC/ESI-MS/MS (Ion Trap) in positive ionization mode, with single reaction monitoring (SRM) acquisition. Three sample types (hard, pasta filata and fresh cheese) were used for method evaluation. Recoveries were mostly higher than 90%; MDLs ranged from 0.02 to 0.26 mgkg(-1), and MQLs were included between 0.07 and 0.88 mgkg(-1). Due to matrix effect, quantitation was performed by referring to a matrix matched calibration curve, for each cheese typology. This method was also applied to commercial cheese samples, with good results. It appears fast, reliable and suitable for both screening and confirmation of the presence and quantitation of the preservatives in a single, multi-detection analysis.

  16. Quantification of X. laevis vitellogenin by liquid chromatography tandem mass spectrometry.

    PubMed

    Luna, Leah G; Coady, Katherine

    2016-02-01

    Over the last several decades, there has been an increase in public awareness and regulatory activity in regard to the presence of emerging contaminants in the environment that may have the potential to interact with the endocrine system of exposed wildlife. Alterations in vitellogenin (VTG), a high density yolk precursor protein, can indicate endocrine activity in oviparous species, including many fish and amphibians. While various methodologies and experiments have been performed to characterize baseline VTG concentrations among commonly studied fish species, fewer methodologies for accurately quantifying amphibian VTG are available. Since there is relatively little information available on background VTG levels in male and female frogs, the present investigation set out to quantify baseline levels of VTG in juvenile as well as adult male and female African clawed frogs (Xenopus laevis) using a newly developed liquid chromatography tandem mass spectrometry method. This new methodology for quantifying VTG in X. laevis frog blood plasma can be applied in mechanistic and toxicity studies with X. laevis to better characterize potential endocrine modes of action.

  17. Multiresidue analysis of environmental pollutants in edible vegetable oils by gas chromatography-tandem mass spectrometry.

    PubMed

    Zhou, Rui-Ze; Jiang, Jie; Mao, Ting; Zhao, Ya-Song; Lu, Yong

    2016-09-15

    A novel multiresidue determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters (PAEs) and alkylphenols (APs) in edible vegetable oils was developed. The samples were extracted with hexane-saturated acetonitrile, and after concentration, the extract was directly qualitatively and quantitatively analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS) with multiple reaction monitoring (MRM) in positive ion mode. The calibration curve displayed good linearity in the range of 2-100 μg/L, with correlation coefficients greater than 0.99. The mean recoveries were 70.0-110.8% by analysis of spiked oil, and the relative standard deviations (RSDs) were 2.1-10.2% (n=6), respectively. The limits of detection (LODs) for the 23 PAHs, 17 PAEs and 3 APs were 0.1-1.0 μg/kg, 0.1-4.0 μg/kg and 1.2-3.0 μg/kg, respectively. The established method effectively avoided interference from large amounts of lipids and pigments. It was applied to real sample and shown to be a rapid and reliable alternative for determination and confirmation in routine analysis. PMID:27080878

  18. Effective Leveraging of Targeted Search Spaces for Improving Peptide Identification in Tandem Mass Spectrometry Based Proteomics.

    PubMed

    Shanmugam, Avinash K; Nesvizhskii, Alexey I

    2015-12-01

    In shotgun proteomics, peptides are typically identified using database searching, which involves scoring acquired tandem mass spectra against peptides derived from standard protein sequence databases such as Uniprot, Refseq, or Ensembl. In this strategy, the sensitivity of peptide identification is known to be affected by the size of the search space. Therefore, creating a targeted sequence database containing only peptides likely to be present in the analyzed sample can be a useful technique for improving the sensitivity of peptide identification. In this study, we describe how targeted peptide databases can be created based on the frequency of identification in the global proteome machine database (GPMDB), the largest publicly available repository of peptide and protein identification data. We demonstrate that targeted peptide databases can be easily integrated into existing proteome analysis workflows and describe a computational strategy for minimizing any loss of peptide identifications arising from potential search space incompleteness in the targeted search spaces. We demonstrate the performance of our workflow using several data sets of varying size and sample complexity. PMID:26569054

  19. Determination of homocitrulline in urine of patients with HHH syndrome by liquid chromatography tandem mass spectrometry.

    PubMed

    Al-Dirbashi, Osama Y; Al-Hassnan, Zuhair N; Rashed, Mohamed S

    2006-12-01

    A liquid chromatography tandem mass spectrometric method is described for the analysis of homocitrulline in human urine, a key metabolite in the differential diagnosis of hyperammonemia, hyperornithinemia, homocitrullinuria (HHH) syndrome. Urine samples were prepared by mere five-fold dilution with a mixture of internal standards (2H2-citrulline and 2H3-creatinine) used for the simultaneous quantification of creatinine. Analytes were separated on a cyano column and eluted isocratically within seven min. Detection was achieved by monitoring transitions of 190 > 84 and 190 > 127 for homocitrulline, 178 > 115 for 2H2-citrulline, 114 > 44 for creatinine and 117 > 47 for 2H3-creatinine. Calibration curves were linear up to 100 micromol/L. Intraday (n = 7) and interday (n = 6) variations were less than 10%. In urine samples from three siblings confirmed to have HHH syndrome, homocitrulline levels were at 13.3 (74), 21.1 (50) and 108.2 (103) mmol/mol creatinine (micromol/L). Control values were 0-9 mmol/mol creatinine (n = 120). The current method solves specificity issues in homocitrulline determination often encountered with some ninhydrin-based systems (coelution with methionine) and some o-phthalaldehyde-based ones (coelution with taurine), and presents an attractive alternative with a relatively high throughput. PMID:17053917

  20. Development of a dedicated peptide tandem mass spectral library for conservation science.

    PubMed

    Fremout, Wim; Dhaenens, Maarten; Saverwyns, Steven; Sanyova, Jana; Vandenabeele, Peter; Deforce, Dieter; Moens, Luc

    2012-05-30

    In recent years, the use of liquid chromatography tandem mass spectrometry (LC-MS/MS) on tryptic digests of cultural heritage objects has attracted much attention. It allows for unambiguous identification of peptides and proteins, and even in complex mixtures species-specific identification becomes feasible with minimal sample consumption. Determination of the peptides is commonly based on theoretical cleavage of known protein sequences and on comparison of the expected peptide fragments with those found in the MS/MS spectra. In this approach, complex computer programs, such as Mascot, perform well identifying known proteins, but fail when protein sequences are unknown or incomplete. Often, when trying to distinguish evolutionarily well preserved collagens of different species, Mascot lacks the required specificity. Complementary and often more accurate information on the proteins can be obtained using a reference library of MS/MS spectra of species-specific peptides. Therefore, a library dedicated to various sources of proteins in works of art was set up, with an initial focus on collagen rich materials. This paper discusses the construction and the advantages of this spectral library for conservation science, and its application on a number of samples from historical works of art.

  1. A Derivative Method with Free Radical Oxidation to Predict Resveratrol Metabolites by Tandem Mass Spectrometry

    PubMed Central

    Liu, Wangta; Shiue, Yow-Ling; Lin, Yi-Reng; Lin, Hugo You-Hsien; Liang, Shih-Shin

    2015-01-01

    In this study, we demonstrated an oxidative method with free radical to generate 3,5,4′-trihydroxy-trans-stilbene (trans-resveratrol) metabolites and detect sequentially by an autosampler coupling with liquid chromatography electrospray ionization tandem mass spectrometer (LC-ESI–MS/MS). In this oxidative method, the free radical initiator, ammonium persulfate (APS), was placed in a sample bottle containing resveratrol to produce oxidative derivatives, and the reaction progress was tracked by autosampler sequencing. Resveratrol, a natural product with purported cancer preventative qualities, produces metabolites including dihydroresveratrol, 3,4′-dihydroxy-trans-stilbene, lunularin, resveratrol monosulfate, and dihydroresveratrol monosulfate by free radical oxidation. Using APS free radical, the concentrations of resveratrol derivatives differ as a function of time. Besides simple, convenient and time- and labor saving, the advantages of free radical oxidative method of its in situ generation of oxidative derivatives followed by LC-ESI–MS/MS can be utilized to evaluate different metabolites in various conditions. PMID:27594817

  2. Determination of ethyl glucuronide in human hair by hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    PubMed

    Yaldiz, Fadile; Daglioglu, Nebile; Hilal, Ahmet; Keten, Alper; Gülmen, Mete Korkut

    2013-10-01

    Ethyl glucuronide (EtG) is a direct metabolite of ethanol and has been utilized as a marker for alcohol intake. This study presents development, validation and application of a new hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the analysis of EtG in human hair samples. The linearity was assessed in the range of 5-2000 pg/mg hair, with a correlation coefficient of >0.99. The method was selective and sensitive, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.05 pg/mg and 0.18 pg/mg in hair, respectively. Differently from the extraction procedures in the literature, a fast and simple liquid-liquid method was used and highest recoveries and cleanest extracts were obtained. The method was successfully applied to 30 human hair samples which were taken from those who state they consume alcohol. EtG concentrations in the hair samples of alcohol users participated in this study, ranged between 1.34 and 82.73 pg/mg. From the concentration of EtG in hair strands 20 of the 30 subjects can be considered regular moderate drinkers. PMID:24112322

  3. Measurement of phthalates diesters in food using gas chromatography-tandem mass spectrometry.

    PubMed

    Cariou, Ronan; Larvor, Frédéric; Monteau, Fabrice; Marchand, Philippe; Bichon, Emmanuelle; Dervilly-Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno

    2016-04-01

    An analytical strategy dedicated to 4 major phthalate diesters (DiBP, DnBP, BBzP and DEHP) monitoring in food items has been developed and validated according to normalized guidelines. The method has been applied to a wide range of foodstuffs (n=54) to generate first-ever occurrence data at the French level. This method involves separation and detection using gas chromatography coupled to tandem mass spectrometry, in electron ionisation with highly specific selected reaction monitoring, quantification being performed according to the isotope dilution principle. A particular attention has been paid to background contamination management at any stage of the analytical process, from the sampling to the expression of the results. Limits of reporting, defined as statistically different from background contamination, were found to be 2.7, 0.53, 0.18 and 3.4 μg kg(-1), and relative combined uncertainties were finally found to be 7.6%, 12.2%, 12.0% and 14.1%, for DiBP, DnBP, BBzP and DEHP, respectively.

  4. Analysis of the Glycoproteome of Toxoplasma gondii using Lectin Affinity Chromatography and Tandem Mass Spectrometry

    PubMed Central

    Luo, Qilie; Upadhya, Rajendra; Zhang, Hong; Madrid-Aliste, Carlos; Nieves, Edward; Kim, Kami; Angeletti, Ruth Hogue; Weiss, Louis M.

    2011-01-01

    Glycoproteins are involved in many important molecular recognition processes including invasion, adhesion, differentiation, and development. To identify the glycoproteins of Toxoplasma gondii, a proteomic analysis was undertaken. T. gondii proteins were prepared and fractioned using lectin affinity chromatography. The proteins in each fraction were then separated using SDS-PAGE and identified by tryptic in gel digestion followed by tandem mass spectrometry. Utilizing these methods 132 proteins were identified. Among the identified proteins were 17 surface proteins, 9 microneme proteins, 15 rhoptry proteins, 11 heat shock proteins (HSP), and 32 hypothetical proteins. Several proteins had 1 to 5 transmembrane domains (TMD) with some being as large as 608.3 kDa. Both lectin-fluorescence labeling and lectin blotting were employed to confirm the presence of carbohydrates on the surface or cytoplasm of T. gondii parasites. PCR demonstrated that selected hypothetical proteins were expressed in T. gondii tachyzoites. This is data provides a large scale analysis of the T. gondii glycoproteome. Studies of the function of glycosylation of these proteins may help elucidate mechanism(s) involved in invasion improving drug therapy as well as identify glycoproteins that may prove to be useful as vaccine candidates. PMID:21920448

  5. Protein Identification False Discovery Rates for Very Large Proteomics Data Sets Generated by Tandem Mass Spectrometry*

    PubMed Central

    Reiter, Lukas; Claassen, Manfred; Schrimpf, Sabine P.; Jovanovic, Marko; Schmidt, Alexander; Buhmann, Joachim M.; Hengartner, Michael O.; Aebersold, Ruedi

    2009-01-01

    Comprehensive characterization of a proteome is a fundamental goal in proteomics. To achieve saturation coverage of a proteome or specific subproteome via tandem mass spectrometric identification of tryptic protein sample digests, proteomics data sets are growing dramatically in size and heterogeneity. The trend toward very large integrated data sets poses so far unsolved challenges to control the uncertainty of protein identifications going beyond well established confidence measures for peptide-spectrum matches. We present MAYU, a novel strategy that reliably estimates false discovery rates for protein identifications in large scale data sets. We validated and applied MAYU using various large proteomics data sets. The data show that the size of the data set has an important and previously underestimated impact on the reliability of protein identifications. We particularly found that protein false discovery rates are significantly elevated compared with those of peptide-spectrum matches. The function provided by MAYU is critical to control the quality of proteome data repositories and thereby to enhance any study relying on these data sources. The MAYU software is available as standalone software and also integrated into the Trans-Proteomic Pipeline. PMID:19608599

  6. [Determination of gossypol in edible vegetable oil with high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Wenhua; Huang, Chaoqun; Xie, Wen; Shen, Li

    2014-06-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of gossypol in edible vegetable oil. The sample was extracted with ethyl alcohol by vortex-excited oscillation. The extract was cleaned up by 0.22 microm filter membrane and centrifuged for 5 min at 4 000 r/min after standing in a fridge at 4 degrees C for 30 min. The compound was separated on a C18 column (100 mm x 2.1 mm, 3.5 microm) with acetonitrile and 1% (v/v) formic acid aqueous solution as mobile phase. The detection of gossypol was carried out by LC-MS/MS with positive electrospray ionization under multiple reaction monitoring (MRM) mode using external standard method. The limits of quantification (S/N > 10) of gossypol in edible vegetable oil was 1 mg/kg. The recoveries were from 87.4% to 100% at the spiked levels of 1, 2, 200 mg/kg of gossypol in edible vegetable oil with the relative standard deviations (RSDs) between 3.9% and 12.2%. The method, with high sensitivity, good precision and high recovery, was suitable for the confirmation and quantification of gossypol residue in edible vegetable oil.

  7. Tandem mass spectrometry in metallomics and the involving role of ICP-MS detection: a review.

    PubMed

    Vogiatzis, C G; Zachariadis, G A

    2014-03-28

    Metallomics is a relatively new branch of omics with a growing interest. The study of metallomes is becoming more focused in certain metabolites and the screening of various categories of analytes using a robust analytical methodology is more than appealing. In this context, when dealing with the challenge of identifying a certain species or specify a particular molecular structure, tandem mass spectrometry (MS/MS) is a reliable tool. Moreover, MS/MS instrumentation is recommended in hyphenated chromatographic techniques with MS detection such as LC-MS, where primary molecular species suffer minor fragmentation (soft-ionization techniques). ICP-MS is widely used in metallomics with its main advantages being the provided high sensitivity and selectivity. Usually, analyzes utilize ICP-MS as the main detection. Its role in proteomics is significant as an alternating choice for protein and peptide quantifications. In this review, we discuss modern trends and applications of MS/MS in the important and growing field of metallomics. These reports concern the identification, characterization and determination of various metal species such as metalloproteins, metallo-DNA adducts, metal-labeled molecules and other metal binding biomolecules. Such assays also present new and interesting hyphenated instrumentation and novel sophisticated apparatus. In addition, we designate the role of ICP-MS in the mentioned contributions and in the same scope we highlight some general analytical strategies.

  8. Simultaneous determination of cosmetics ingredients in nail products by fast gas chromatography with tandem mass spectrometry.

    PubMed

    Zhou, Wanlong; Wang, Perry G; Wittenberg, James B; Rua, Diego; Krynitsky, Alexander J

    2016-05-13

    A rapid and sensitive gas chromatography with tandem mass spectrometry (GC-MS/MS) method has been developed and validated to quantitatively determine cosmetic ingredients, such as toluene, N-methylpyrrolidone, 2,4-dihydroxybenzophenone (benzophenone-1, BP-1), and diethylene glycol dimethacrylate, in nail products. In this procedure, test portions were extracted with acetone, followed by vortexing, sonication, centrifugation, and filtration. During the extraction procedure, BP-1 was derivatized making it amenable to GC-MS analysis, using N,O-​bis(trimethylsilyl)​trifluoroacetamide. The four ingredients were quantified by GC-MS/MS in an electron ionization mode. Four corresponding stable isotopically labeled analogues were selected as internal standards, which were added at the beginning of the sample preparation to correct for recoveries and matrix effects. The validated method was used to screen 34 commercial nail products for these four cosmetic ingredients. The most common ingredients detected in the nail products were toluene and BP-1. Toluene was detected in 26 products and ranged from 1.36 to 173,000μg/g. BP-1 ranged from 18.3 to 2,370μg/g in 10 products.

  9. Simultaneous determination of cosmetics ingredients in nail products by fast gas chromatography with tandem mass spectrometry.

    PubMed

    Zhou, Wanlong; Wang, Perry G; Wittenberg, James B; Rua, Diego; Krynitsky, Alexander J

    2016-05-13

    A rapid and sensitive gas chromatography with tandem mass spectrometry (GC-MS/MS) method has been developed and validated to quantitatively determine cosmetic ingredients, such as toluene, N-methylpyrrolidone, 2,4-dihydroxybenzophenone (benzophenone-1, BP-1), and diethylene glycol dimethacrylate, in nail products. In this procedure, test portions were extracted with acetone, followed by vortexing, sonication, centrifugation, and filtration. During the extraction procedure, BP-1 was derivatized making it amenable to GC-MS analysis, using N,O-​bis(trimethylsilyl)​trifluoroacetamide. The four ingredients were quantified by GC-MS/MS in an electron ionization mode. Four corresponding stable isotopically labeled analogues were selected as internal standards, which were added at the beginning of the sample preparation to correct for recoveries and matrix effects. The validated method was used to screen 34 commercial nail products for these four cosmetic ingredients. The most common ingredients detected in the nail products were toluene and BP-1. Toluene was detected in 26 products and ranged from 1.36 to 173,000μg/g. BP-1 ranged from 18.3 to 2,370μg/g in 10 products. PMID:27083261

  10. Determination of cosmogenic Ca-41 in a meteorite with tandem accelerator mass spectrometry

    NASA Technical Reports Server (NTRS)

    Kubik, P. W.; Elmore, D.; Conard, N. J.; Nishiizumi, K.; Arnold, J. R.

    1986-01-01

    The first use of tandem accelerator mass spectrometry (TAMS) to measure the content of Ca-41 in a natural sample, the iron Bogou meteorite, is reported. Ca in the samples was extracted by hydroxide precipitation and purified by means of a caution exchange resin (AG 50W-X8). After adding 4 percent ammonium oxide, the precipitate was ignited to CaO in a quartz vial at about 1100 C. The Ca-41/Ca ratios were determined following acceleration by alternate measurements of the Ca-40 beam current in an image Faraday cup. Ca-41 particles were also measured using a gas counter. The measured Ca-41/Ca ratio was 3.8 + or -0.6 x 10 to the 12th, which corresponds to a Ca-41 activity of 6.9 + or -1.1 d.p.m. per kg. Calculation of the half-life of Ca-41 in the Bogou meteorite yielded an age of 103,000 years.

  11. Determination of porphyrins in oral bacteria by liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Fyrestam, Jonas; Bjurshammar, Nadja; Paulsson, Elin; Johannsen, Annsofi; Östman, Conny

    2015-09-01

    Biofilms in the oral cavity can be visualized by fluorescence and a common assumption is that the endogenously produced porphyrins in certain bacteria give rise to this fluorescence. Porphyrin content in oral bacteria has been sparingly investigated, and non-selective detection techniques such as utilizing the Soret fluorescence band of porphyrins are often used. In the present study, a quantitative and selective method for the determination of porphyrins in oral bacteria has been developed and validated using high performance liquid chromatography-tandem mass spectrometry. Lysis of bacteria using Tris-EDTA buffer together with ultrasonication showed high microbial killing efficiency ≥99.98%, and sample clean-up using C18-solid phase extraction resulted in low matrix effects ≤14% for all analytes. Using this method, the porphyrin content was determined in the two oral pathogens Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis, as well as for baker's yeast, Saccharomyces cerevisiae. Uroporphyrin, 7-carboxylporphyrin, 6-carboxylporphyrin, coproporphyrin, and protoporphyrin IX were identified in the investigated microorganisms, and it was shown that the porphyrin profile differs between the two bacteria, as well as for S. cerevisiae. To our knowledge, this is the first time the porphyrin profile has been determined for the bacterium A. actinomycetemcomitans. PMID:26168965

  12. Expanding tandem mass spectral libraries of phosphorylated peptides: advances and applications.

    PubMed

    Hu, Yingwei; Lam, Henry

    2013-12-01

    The identification of phosphorylated proteins remains a challenge in proteomics, partially due to the difficulty in assigning tandem mass (MS/MS) spectra to their originating peptide sequences with correct phosphosite localization. Because of its advantages in efficiency and sensitivity, spectral library searching is a promising alternative to conventional sequence database searching. Our work aims to construct the largest collision-induced dissociation (CID) MS/MS spectral libraries of phosphorylated peptides in human (Homo sapiens) and four model organisms (Saccharomyces cerevisiae, Drosophila melanogaster, Caenorhabditis elegans, and Mus musculus) to date, to facilitate phosphorylated peptide identification by spectral library searching. We employed state-of-the-art search methods to published data and applied two recently published phosphorylation site localization tools (PhosphoRS and PTMProphet) to ascertain the phosphorylation sites. To further increase the coverage of this library, we predicted "semi-empirical" spectra for peptides containing known phosphorylation sites from the corresponding template unphosphorylated peptide spectra. The performance of the spectral libraries built were evaluated and found to be superior to conventional database searching in terms of sensitivity. Updated spectral libraries of phosphorylated peptides are made freely available for use with the spectral search engine SpectraST. The work flow being developed will be used to continuously update the libraries when new data become available.

  13. Determination of household chemicals using gas chromatography and liquid chromatography with tandem mass spectrometry.

    PubMed

    Trenholm, Rebecca A; Vanderford, Brett J; Drewes, Jörg E; Snyder, Shane A

    2008-05-01

    A method has been developed for the determination of 24 household high production volume (HPV) chemicals in municipal wastewater systems using solid-phase extraction (SPE) and analyses using both gas chromatography and liquid chromatography, each with tandem mass spectrometry (GC-MS/MS and LC-MS/MS). Target compounds include pesticides, antioxidants, fragrances, plasticizers, preservatives and personal care products. Method reporting limits ranged from 0.1 to 100 ng/L in water and recoveries for most compounds were between 54 and 112%. Household HPVs were consistently detected in raw sewage entering three full-scale wastewater treatment plants. Compounds such as vanillin, DEET, benzophenone, 3-indolebutyric acid, bisphenol A, triclosan and triclocarban were detected in all wastewater influent and effluent samples, but were significantly lower in the effluent. Many of the remaining compounds were detected in the influent, but below detection in effluent samples. Menthol and phenoxyethanol had the highest observed concentrations in influent samples ranging from 1.5 to 13 microg/L for menthol, and 8.8 to 22 microg/L for phenoxyethanol. MGK-11, methylresorcinol, trifluralin, hexabromododecane, acriflavin and atrazine were not detected in any samples. The method described here detects a broad range of HPV chemicals with great sensitivity and selectivity.

  14. Liquid chromatography tandem mass spectrometry determination of maduramycin residues in the tissues of broiler chickens.

    PubMed

    Tkáciková, Sona; Kozárová, Ivona; Máté, Dionýz

    2010-09-01

    Maduramycin is a polyether ionophoric coccidiostat used to prevent coccidiosis in poultry at a prescribed concentration over a certain time interval. Due to public health concerns about the presence of coccidiostat residues in poultry, the aim of the present study was to determine the level of maduramycin residues in the tissues of broiler chickens fed commercially produced feed containing 5 mg kg(-1) of maduramycin in complete feed throughout the 5-day withdrawal period (WP). The residues were investigated by liquid chromatography (LC) coupled with electrospray ionisation (ESI) tandem mass spectrometry (MS/MS). The limit of detection (LOD) and limit of quantification (LOQ) of the method were 0.3 and 0.8 microg kg(-1), respectively. The average recovery based on matrix-fortified calibrations for chicken tissues was 90%. Maduramycin was found to be rapidly distributed in all tissues. The highest concentrations of maduramycin residues were found in the heart followed by the skin, liver, gizzard, kidneys and, finally, muscle (thigh and breast). On day 5 of the WP, residue concentrations of maduramycin did not decline below the LOQ of the method. Our results emphasize the need to establish a maximum residue limit (MRL) for maduramycin to control its residue levels in edible tissues from chickens before slaughter. PMID:20521190

  15. Comprehensive characterization of anticoagulant rodenticides in sludge by liquid chromatography-tandem mass spectrometry.

    PubMed

    Gómez-Canela, Cristian; Lacorte, Silvia

    2016-08-01

    The occurrence of 10 commonly used anticoagulant rodenticides in centrifuged sludge of 27 wastewater treatment plants was evaluated using solid-liquid extraction (SLE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Activated carbon, alumina, and Florisil cartridges with methanol/dichloromethane as eluting solvents were tested in combination with primary-secondary amine (PSA) to optimize an efficient sample cleanup. PSA in combination with Florisil was the best methodology to extract anticoagulant rodenticides in sludge providing recoveries between 42 ± 0.5 and 100 ± 2 %. Warfarin, bromadiolone, ferulenol, and coumachlor were the most ubiquitous compounds in sludge at concentrations up to 84.2 ng g(-1) for the latter. Coumatetralyl, dicoumarol, and brodifacoum were detected sporadically at levels between 6.1 and 17.4 ng g(-1). On the contrary, acenocoumarol, difenacoum, and flocoumafen were not detected in any sample. Finally, we estimated the amount of anticoagulant rodenticides discharged via sludge in order to determine the potential impact to agricultural soil according to different sludge usage practices in the region investigated. This study demonstrates that anticoagulant rodenticides are accumulated in sludge during activated sludge treatment and that the application of sludge as fertilizers may pose a future environmental risk, if not controlled. PMID:27146526

  16. Metabolism study of boldenone in human urine by gas chromatography-tandem mass spectrometry.

    PubMed

    Wu, Xinchen; Gao, Feng; Zhang, Wenxin; Ni, Jian

    2015-11-10

    Boldenone (BOLD), an anabolic steroid, is likely to be abused in livestock breeding and in sports. Although some of BOLD metabolites in human urine, such as 5β-adrost-1-en-17β-ol-3-one (BM1), have been detected, investigations on their excretion patterns for both genders are insufficient. Moreover, little research on 17α-BOLD glucuronide as a metabolite in human urine has been reported. The aim of this study is to make a contribution to the knowledge of 17β-BOLD metabolism in humans. Three male and three female volunteers were orally administrated with 30mg 17β-BOLD. Urine samples were collected and analyzed with gas chromatography-tandem mass spectrometry. The data proved that 17β-BOLD, BM1, and 17α-BOLD were excreted in urine in both free and glucuronic conjugated forms after administration of 17β-BOLD. For most subjects, the urinary concentrations of BM1 were higher than that of 17β-BOLD. 17α-BOLD was excreted in small amounts. 17α-BOLD, 17β-BOLD, and BM1 were present naturally in urine with low concentrations. Administration of 30mg 17β-BOLD could not influence the excretion profiles of urinary androsterone, etiocholanolone, and testosterone/epitestosterone ratio. There were no differences in BOLD metabolic patterns between man and woman.

  17. Metabolism study of boldenone in human urine by gas chromatography-tandem mass spectrometry.

    PubMed

    Wu, Xinchen; Gao, Feng; Zhang, Wenxin; Ni, Jian

    2015-11-10

    Boldenone (BOLD), an anabolic steroid, is likely to be abused in livestock breeding and in sports. Although some of BOLD metabolites in human urine, such as 5β-adrost-1-en-17β-ol-3-one (BM1), have been detected, investigations on their excretion patterns for both genders are insufficient. Moreover, little research on 17α-BOLD glucuronide as a metabolite in human urine has been reported. The aim of this study is to make a contribution to the knowledge of 17β-BOLD metabolism in humans. Three male and three female volunteers were orally administrated with 30mg 17β-BOLD. Urine samples were collected and analyzed with gas chromatography-tandem mass spectrometry. The data proved that 17β-BOLD, BM1, and 17α-BOLD were excreted in urine in both free and glucuronic conjugated forms after administration of 17β-BOLD. For most subjects, the urinary concentrations of BM1 were higher than that of 17β-BOLD. 17α-BOLD was excreted in small amounts. 17α-BOLD, 17β-BOLD, and BM1 were present naturally in urine with low concentrations. Administration of 30mg 17β-BOLD could not influence the excretion profiles of urinary androsterone, etiocholanolone, and testosterone/epitestosterone ratio. There were no differences in BOLD metabolic patterns between man and woman. PMID:26319750

  18. [Determination of five synthetic sweeteners in wines using high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Ji, Chao; Feng, Feng; Chen, Zhengxing; Sun, Li; Chu, Xiaogang

    2010-08-01

    A high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS) method for the determination of five synthetic sweeteners (acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame) in wines has been developed. The HPLC separation was carried out on an Ultimate C18 column (100 mm x 2.1 mm, 3 microm). Several parameters, including the composition and pH of the mobile phase, column temperature and the monitor ions, were optimized for improving the chromatographic performance and the sensitivity of determination. The results demonstrated that the separation can be completed in less than 5 min by gradient elution with 20 mmol/L ammonium formate and 0.1% (v/v) formic acid (pH 3.8) and methanol as the mobile phase. The column temperature was kept at 45 degrees C. When the analytes were detected by ESI -MS/MS under multiple reaction monitoring mode, the detection limits were 0.6, 5, 1, 0.8 and 0.2 microg/L for acesulfame, sodium saccharin, sodium cyclamate, aspartame and neotame, respectively. The average recoveries ranged from 87.2% to 103%. The relative standard deviations were not more than 1.2%. This method is rapid, accurate, highly sensitive and suitable for the quality control of low concentration of the synthetic sweeteners, which are illegally added to wines and other foods with complex matrices.

  19. Tandem Mass Spectrometry for Characterization of Covalent Adducts of DNA with Anti-cancer Therapeutics

    PubMed Central

    Silvestri, Catherine; Brodbelt, Jennifer S.

    2012-01-01

    The chemotherapeutic activities of many anticancer and antibacterial drugs arise from their interactions with nucleic acid substrates. Some of these ligands interact with DNA in a way that causes conformational changes or damage to the nucleic acid targets, ultimately altering recognition by key DNA-specific enzymes, interfering with DNA transcription or prohibiting replication, and terminating cell growth and proliferation. The design and synthesis of ligands that bind to nucleic acids remains a dynamic field in medicinal chemistry and pharmaceutical research. The quest for more selective and efficacious DNA-interactive anti-cancer chemotherapeutics has likewise catalyzed the need for sensitive analytical methods that can provide structural information about the nature of the resulting DNA adducts and provide insight into the mechanistic pathways of the DNA/drug interactions and the impact on the cellular processes in biological systems. This review focuses on the array of tandem mass spectrometric strategies developed and applied for characterization of covalent adducts formed between DNA and anti-cancer ligands. PMID:23150278

  20. Determination of porphyrins in oral bacteria by liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Fyrestam, Jonas; Bjurshammar, Nadja; Paulsson, Elin; Johannsen, Annsofi; Östman, Conny

    2015-09-01

    Biofilms in the oral cavity can be visualized by fluorescence and a common assumption is that the endogenously produced porphyrins in certain bacteria give rise to this fluorescence. Porphyrin content in oral bacteria has been sparingly investigated, and non-selective detection techniques such as utilizing the Soret fluorescence band of porphyrins are often used. In the present study, a quantitative and selective method for the determination of porphyrins in oral bacteria has been developed and validated using high performance liquid chromatography-tandem mass spectrometry. Lysis of bacteria using Tris-EDTA buffer together with ultrasonication showed high microbial killing efficiency ≥99.98%, and sample clean-up using C18-solid phase extraction resulted in low matrix effects ≤14% for all analytes. Using this method, the porphyrin content was determined in the two oral pathogens Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis, as well as for baker's yeast, Saccharomyces cerevisiae. Uroporphyrin, 7-carboxylporphyrin, 6-carboxylporphyrin, coproporphyrin, and protoporphyrin IX were identified in the investigated microorganisms, and it was shown that the porphyrin profile differs between the two bacteria, as well as for S. cerevisiae. To our knowledge, this is the first time the porphyrin profile has been determined for the bacterium A. actinomycetemcomitans.

  1. Fate and occurrence of alkylphenolic compounds in sewage sludges determined by liquid chromatography tandem mass spectrometry.

    PubMed

    Koh, Y K K; Chiu, T Y; Paterakis, N; Boobis, A; Scrimshawe, M D; Lester, J N; Cartmell, E

    2009-12-01

    An analytical method has been developed and applied to determine the concentrations of the nonionic alkylphenol polyethoxylate surfactants and their metabolites, alkylphenoxy carboxylates and alkyphenols, in sewage sludges. The compounds were extracted with methanol/acetone (1:1 v/v) from sludge, and concentrated extracts were cleaned by silica solid-phase extraction prior to determination by liquid chromatography tandem mass spectrometry. The recoveries, determined by spiking sewage sludge at two concentrations, ranged from 51% to 89% with method detection limits from 6 microg kg(-1) to 60 microg kg(-1). The methodology was subsequently applied to sludge samples obtained from a carbonaceous activated sludge plant, a nitrifying/denitrifying activated sludge plant and a nitrifying/ denitrifying activated sludge plant with phosphorus removal. Concentrations of nonylphenolic compounds were two to three times higher than their octyl analogues. Long-chain nonylphenol polyethoxylates (NP3-12EO) ranged from 16 microg kg(-1) to 11754 microg kg(-1). The estrogenic metabolite nonylphenol was present at concentrations ranging from 33 microg kg(-1) to 6696 microg kg(-1). PMID:20088206

  2. Pharmacokinetic studies of novel berberine derivatives with ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wang, Wenchao; Shen, Qin; Liang, Hui; Hua, Changlong; Liu, Yuhui; Li, Fengzhi; Li, Qingyong

    2016-09-15

    An ultra-performance liquid chromatography with tandem mass spectrometric detection method was developed for the detection of berberine and its derivatives (A4, B4) in rat plasma and other organs. This validated method was successfully applied to our pharmacokinetic study of BBR derivatives in rats. At the same dose of administration, the Cmax of B4 was about eight times higher than BBR, and its half-life was approximately two times longer than BBR, according to the bigger areas under plasma concentration curves. Inversely, the pharmacokinetic parameter levels of A4 were all inferior to BBR, suggesting a tight structure-activity relationship of these compounds. Small dose of parenteral administration was used for the study of absolute oral bioavailability of A4, B4, and BBR, and the results calculated were 0.12%, 3.4% and 0.7%, respectively. The accumulations of B4 among all organs were intestine>liver>heart>kidney>lung>spleen>plasma, proving a deeply targeting property of B4, which met our experimental assumption. Together, the experimental results proved that compared with BBR and A4, the derivative B4 had higher absolute oral bioavailability and the ability of deeply targeting so that can be likely used in some organ-targeted diseases. PMID:27494281

  3. Liquid chromatography-tandem mass spectrometry analysis of urine specimens for K2 (JWH-018) metabolites.

    PubMed

    ElSohly, Mahmoud A; Gul, Waseem; Elsohly, Kareem M; Murphy, Timothy P; Madgula, Vamsi L M; Khan, Shabana I

    2011-09-01

    Marijuana is the most widely used drug of abuse all over the world. The major active constituent of the drug is Δ⁹- tetrahydrocannabinol (Δ⁹-THC). Δ⁹-THC exerts its psychological activities by interacting with the cannabinoid receptors (CB₁ and CB₂) in the brain. JWH-018, HU-210, and CP-47497, with CB₁ agonist activity (similar to Δ⁹-THC), have been used by the drug culture to spike smokable herbal products to attain psychological effects similar to those obtained by smoking marijuana. The products spiked with these CB₁ agonists are commonly referred to as "Spice" or "K2". The most common compound used in these products is JWH-018 and related compounds (JWH-073 and JWH-250). Little work has been done on the detection of these synthetic cannabimimetic compounds in biological specimens. This report investigated the metabolism of JWH-018 by human liver microsomes, identification of the metabolites of JWH-018 in urine specimen of an individual who admitted use of the drug, and reports on the quantitation of three of its urinary metabolites, namely the 6-OH-, the N-alkyl OH (terminal hydroxyl)-, and the N-alkyl terminal carboxy metabolites using liquid chromatography-tandem mass spectrometry. The concentrations of these metabolites are determined in several forensic urine specimens.

  4. GLYCEROPHOSPHOLIPID ANALYSIS OF EASTERN RED BAT (Lasiurus borealis) HAIR BY ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMET

    PubMed Central

    Pannkuk, Evan L.; McGuire, Liam P.; Gilmore, David F.; Savary, Brett J.; Risch, Thomas S.

    2014-01-01

    Pilosebaceous units found in the mammalian integument are composed of a hair follicle, the proximal portion of the hair shaft, a sebaceous gland, and the erector pili muscle. Pilosebaceous units release protective oils, or sebum, by holocrine secretion onto skin and hair through rupturing of sebocytes. Sebum is largely composed of polar and neutral lipids including glycerolipids, free fatty acids, sterols, wax esters, sterol esters, and squalene. In addition to these lipid classes, there is a small proportion of ionic/anionic glycerophospholipids (GPs). Composition of GPs on hair is rarely addressed despite their broad biological activities as signaling molecules and membrane stability. Furthermore, knowledge on GP composition in bats is lacking. Bat GP composition is important to document due to GP roles ranging from decreasing drag during migration to interaction with the integumentary microbiome. In this study, we analyzed GP molecular composition with liquid chromatography electrospray ionization tandem mass spectrometry and compared GP content to previous literature. A total of 152 GPs were detected. Broad GP classes identified include lysophosphatidylcholine, phosphatidylcholine (PC), lysophosphatidylethanolamine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidic acid, and phosphatidylglycerol, with PC being the most abundant class. The acyl components were consistent with fatty acid methyl esters and triacylglyceride moieties found in Eastern red bat sebum. GP proportions of the hair surface were different from a previous study on bat lung surfactants. This study determined the broad class and molecular species of bat sebum GPs that may be used in future ecological studies in vespertilionid bats. PMID:24532214

  5. Determination of 17alpha-methyltestosterone in muscle tissues of tilapia, rainbow trout, and salmon using liquid chromatography-tandem mass spectrometry.

    PubMed

    Chu, Pak-Sin; Lopez, Mayda; Serfling, Stan; Gieseker, Charlie; Reimschuessel, Renate

    2006-05-01

    An analytical method was developed to quantitate and confirm the presence of 17alpha-methyltestosterone in the muscles of tilapia, rainbow trout, and salmon. The method employed two liquid-liquid partitioning steps and two solid-phase extraction columns for sample cleanup. The final extracts were analyzed on an isocratic reverse-phase liquid chromatography-tandem mass spectrometry system with atmospheric-pressure chemical ionization in the positive ion mode. The method was validated at levels from 0.40 to 1.6 ng/g, with MT-d3 used as an internal standard. The accuracy was between 100% and 110%, and coefficients of variation of <10% were obtained for all three fish species. Muscle tissues from dosed fish were also assayed to demonstrate the effectiveness of the method for recovering the parent drug.

  6. Quantitative determination method for trace amount of penicillin contaminants in commercially available drug product by HPLC coupled with tandem mass spectrometry.

    PubMed

    Takada, Wataru; Adachi, Toshikazu; Kihara, Noriaki; Kitamura, Satoshi; Kitagawa, Teruyuki; Mifune, Masaki; Saito, Yutaka

    2005-02-01

    A quantitative determination method for trace amount of penicillin contaminants in an active pharmaceutical ingredient (API) has been developed. Selective extraction of penicillin contaminants from the matrix containing API and specific separation among penicillin contaminants were achieved through an on-line column switching technique with gradient elution, followed by tandem mass spectrometric determination. Validation was conducted on the developed method in terms of specificity, linearity, accuracy, precision, and detection limit, and appeared reasonable. The detection limit was estimated as 0.03 ng/ml or lower of the concentration of penicillin contaminants in the preparation, corresponding to 4 parts par billion (ppb) against the API. This fulfilled the regulatory requirement by the authorities.

  7. Quantification of biopharmaceuticals and biomarkers in complex biological matrices: a comparison of liquid chromatography coupled to tandem mass spectrometry and ligand binding assays.

    PubMed

    Bults, Peter; van de Merbel, Nico C; Bischoff, Rainer

    2015-08-01

    The quantification of proteins (biopharmaceuticals or biomarkers) in complex biological samples such as blood plasma requires exquisite sensitivity and selectivity, as all biological matrices contain myriads of proteins that are all made of the same 20 proteinogenic amino acids, notwithstanding post-translational modifications. This review describes and compares the two main approaches, namely, ligand binding assays (LBAs) and liquid chromatography coupled to tandem mass spectrometry in the selected reaction monitoring (SRM) mode. While LBAs remain the most widely used approach, SRM assays are gaining interest due to their generally better analytical performance (precision and accuracy) and their capacity for multiplex analyses. This article focuses on the possible reasons for the discrepancies between results obtained by LBAs and SRM assays.

  8. Silymarin in liposomes and ethosomes: pharmacokinetics and tissue distribution in free-moving rats by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chang, Li-Wen; Hou, Mei-Ling; Tsai, Tung-Hu

    2014-12-01

    The aim of this study was to prepare silymarin formulations (silymarin entrapped in liposomes and ethosomes, formulations referred to as LSM and ESM, respectively) to improve oral bioavailability of silymarin and evaluate its tissue distribution by liquid chromatography with tandem mass spectrometry (LC-MS/MS) in free-moving rats. Silibinin is the major active constituent of silymarin, which is the main component to be analyzed. A rapid, sensitive, and repeatable LC-MS/MS method was developed and validated in terms of precision, accuracy, and extraction recovery. Furthermore, the established method was applied to study the pharmacokinetics and tissue distribution of silymarin in rats. The size, ζ potential, and drug release of the formulations were characterized. These results showed that the LSM and ESM encapsulated formulations of silymarin may provide more efficient tissue distribution and increased oral bioavailability, thus improving its therapeutic bioactive properties in the body.

  9. Automated isotope dilution liquid chromatography-tandem mass spectrometry with on-line dilution and solid phase extraction for the measurement of cortisol in human serum sample.

    PubMed

    Kawaguchi, Migaku; Eyama, Sakae; Takatsu, Akiko

    2014-08-01

    A candidate reference measurement procedure involving automated isotope dilution coupled with liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with on-line dilution and solid phase extraction (SPE) has been developed and critically evaluated. We constructed the LC-MS/MS with on-line dilution and SPE system. An isotopically labelled internal standard, cortisol-d4, was added to serum sample. After equilibration, the methanol was added to the sample, and deproteination was performed. Then, the sample was applied to the LC-MS/MS system. The limit of detection (LOD) and limit of quantification (LOQ) were 0.2 and 1ngg(-1), respectively. Excellent precision was obtained with within-day variation (RSD) of 1.9% for ID-LC-MS/MS analysis (n=6). This method, which demonstrates simple, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.

  10. Silymarin in liposomes and ethosomes: pharmacokinetics and tissue distribution in free-moving rats by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chang, Li-Wen; Hou, Mei-Ling; Tsai, Tung-Hu

    2014-12-01

    The aim of this study was to prepare silymarin formulations (silymarin entrapped in liposomes and ethosomes, formulations referred to as LSM and ESM, respectively) to improve oral bioavailability of silymarin and evaluate its tissue distribution by liquid chromatography with tandem mass spectrometry (LC-MS/MS) in free-moving rats. Silibinin is the major active constituent of silymarin, which is the main component to be analyzed. A rapid, sensitive, and repeatable LC-MS/MS method was developed and validated in terms of precision, accuracy, and extraction recovery. Furthermore, the established method was applied to study the pharmacokinetics and tissue distribution of silymarin in rats. The size, ζ potential, and drug release of the formulations were characterized. These results showed that the LSM and ESM encapsulated formulations of silymarin may provide more efficient tissue distribution and increased oral bioavailability, thus improving its therapeutic bioactive properties in the body. PMID:25375210

  11. Simultaneous enantioselective quantification of fluoxetine and norfluoxetine in human milk by direct sample injection using 2-dimensional liquid chromatography-tandem mass spectrometry.

    PubMed

    Alvim-Jr, Joel; Lopes, Bianca Rebelo; Cass, Quezia Bezerra

    2016-06-17

    A two-dimensional liquid chromatography system coupled to triple quadrupole tandem mass spectrometer (2D LC-MS/MS) was employed for the simultaneously quantification of fluoxetine (FLX) and norfluoxetine (NFLX) enantiomers in human milk by direct injection of samples. A restricted access media of bovine serum albumin octadecyl column (RAM-BSAC18) was used in the first dimension for the milk proteins depletion, while an antibiotic-based chiral column was used in the second dimension. The results herein described show good selectivity, extraction efficiency, accuracy, and precision with limits of quantification in the order of 7.5ngmL(-1)for the FLX enantiomers and 10.0ngmL(-1) for NFLX enantiomers. Furthermore, it represents a practical tool in terms of sustainability for the sample preparation of such a difficult matrix.

  12. Isotope dilution for quantitation of steroid estrogens and nonylphenols by gas chromatography with tandem mass spectrometry in septic, soil, and groundwater matrices.

    PubMed

    Stanford, Benjamin D; Weinberg, Howard S

    2007-12-28

    A simplified, in-line solid-phase extraction and clean-up process is presented for rapid extraction and analysis of steroid estrogens and nonylphenols by gas chromatography with tandem mass spectrometry. Isotope dilution with multiple deuterated standards has been developed, evaluated, and verified using this method against standard addition for the analysis of estrone, estradiol, estriol, ethinylestradiol, and 4-nonylphenols in septic, soil, and groundwater matrices. The accuracy and precision of isotope dilution was comparable to standard addition yet was able to quantify analytes with the use of fewer samples by including [(2)H(4)]estradiol, [(2)H(4)]ethinylestradiol, [(2)H(4)]nonylphenol, and estradiol-17-acetate as internal standards. Specific details and validation of the method are presented as are data showing the occurrence of estrogens and nonylphenols in an on-site wastewater treatment (septic) system with advanced stages of pretreatment and recirculation to an office building for non-potable reuse.

  13. Simultaneous enantioselective quantification of fluoxetine and norfluoxetine in human milk by direct sample injection using 2-dimensional liquid chromatography-tandem mass spectrometry.

    PubMed

    Alvim-Jr, Joel; Lopes, Bianca Rebelo; Cass, Quezia Bezerra

    2016-06-17

    A two-dimensional liquid chromatography system coupled to triple quadrupole tandem mass spectrometer (2D LC-MS/MS) was employed for the simultaneously quantification of fluoxetine (FLX) and norfluoxetine (NFLX) enantiomers in human milk by direct injection of samples. A restricted access media of bovine serum albumin octadecyl column (RAM-BSAC18) was used in the first dimension for the milk proteins depletion, while an antibiotic-based chiral column was used in the second dimension. The results herein described show good selectivity, extraction efficiency, accuracy, and precision with limits of quantification in the order of 7.5ngmL(-1)for the FLX enantiomers and 10.0ngmL(-1) for NFLX enantiomers. Furthermore, it represents a practical tool in terms of sustainability for the sample preparation of such a difficult matrix. PMID:27208983

  14. Mass spectrometric characterization of tamoxifene metabolites in human urine utilizing different scan parameters on liquid chromatography/tandem mass spectrometry.

    PubMed

    Mazzarino, Monica; de la Torre, Xavier; Di Santo, Roberto; Fiacco, Ilaria; Rosi, Federica; Botrè, Francesco

    2010-03-01

    Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were considered for the characterization of tamoxifene metabolites in human urine for anti-doping purpose. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 166, 152 and 129) and neutral loss scan (neutral loss of 72 Da and 58 Da) in positive ion mode were assessed to recognize common ions or common losses of tamoxifene metabolites. The applicability of these methods was checked first by infusion and then by the injection of solution of a mixture of reference standards of four tamoxifene metabolites available in our laboratory. The data obtained by the analyses of the mixture of the reference standards showed that the five methods used exhibited satisfactory results for all tamoxifene metabolites considered at a concentration level of 100 ng/mL, whereas the analysis of blank urine samples spiked with the same tamoxifene metabolites at the same concentration showed that the neutral loss scan of 58 Da lacked sufficient specificity and sensitivity. The limit of detection in urine of the compounds studied was in the concentration range 10-100 ng/mL, depending on the compound structure and on the selected product ion. The suitability of these approaches was checked by the analysis of urine samples collected after the administration of a single dose of 20 mg of tamoxifene. Six metabolites were detected: 4-hydroxytamoxifene, 3,4-dihydroxytamoxifene, 3-hydroxy-4-methoxytamoxifene, N-demethyl-4-hydroxytamoxifene, tamoxifene-N-oxide and N-demethyl-3-hydroxy-4-methoxytamoxifene, which is in conformity to our previous work using a time-of-flight (TOF) mass spectrometer in full scan acquisition mode. PMID:20187079

  15. A high-performance liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method for determination of risperidone and 9-hydroxyrisperidone in human plasma.

    PubMed

    Moody, David E; Laycock, John D; Huang, Wei; Foltz, Rodger L

    2004-09-01

    Risperidone, a benzisoxazole derivative, is an antipsychotic agent used for the treatment of schizophrenia. We developed a liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric (LC-APCI-MS-MS) method with improved sensitivity, selectivity, and dynamic range for determination of risperidone and 9-hydroxyrisperidone in human plasma. A structural analogue of risperidone, RO68808 (5 ng/mL), is added as the internal standard to 1 mL of human plasma. Plasma is made basic, extracted with pentane/methylene chloride (3:1), the organic phase evaporated to dryness, and the residue is reconstituted in water with 0.1% formic acid/acetonitrile (20:1). For LC-MS-MS analysis, a Metachem Inertsel HPLC column (2.1 x 150 mm, 5-microm particle size) is connected to a Finnigan TSQ7000 tandem MS via the Finnigan API interface. Both electrospray (ESI) and APCI produced predominantly MH(+) ions for the two analytes and the internal standard. Ions detected by selected reaction monitoring correspond to the following transitions: m/z 411 to 191 for risperidone, m/z 427 to 207 for 9-hydroxyrisperidone, and m/z 421 to 201 for the internal standard. APCI provided a larger dynamic range (0.1 to 25 ng/mL) and better precision and accuracy than ESI. Intrarun accuracy and precision determined at 0.1, 0.25, 2.5, and 15 ng/mL were within 12% of target with %CVs not exceeding 10.9%. Interrun accuracy and precision determined at the same concentrations were within 9.6% of target with %CVs not exceeding 6.7%. Analytes were stable in plasma after 24 h at room temperature, 2 freeze-thaw cycles, and 490 days at -20 degrees C. PMID:15516302

  16. [Determination of 14 aniline derivatives in water by liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhao, Yunzhi; Yang, Ping; Qian, Shu

    2015-05-01

    A new and fast method was developed for the simultaneous determination of 14 aniline derivatives ( ADs) in water by direct injection-liquid chromatography-tandem mass spectrometry (LC-MS/MS) through optimizing chromatographic and mass spectrometric conditions. The water sample was filtered through a 0.45 µm polyether sulfone (PES) microfiltration membrane. The separation was performed on a Shim-pack FC-ODS column (75 mm x 4.6 mm, 3 µm) with methanol-0.1% (v/v) formic acid aqueous solution (35:65, v/v) as mobile phases in gradient elution mode. The flow rate was 0.3 mL/min, and the column temperature was 35 °C. The analytes were detected by LC-MS/MS in multiple reaction monitoring mode. Under the optimized conditions, the analysis of the 14 aniline derivatives was completed within 12 min and the calibration curves showed good linearity with correlation coefficients not less than 0.999. The detection limits of the 14 aniline derivatives ranged from 0.03 µg/L to 4. 19 µg/L. The relative standard deviations of the 14 aniline derivatives in the spiked surface water at three levels (0. 5, 5.0, 20.0 µg/L) were 0.4%-9.4% (n = 6). The proposed method has the advantages of good anti-interference ability, rapidness and high sensitivity. It was successfully applied to the analysis of real samples, and the recoveries of the 14 aniline derivatives in the spiked real samples were 68.0%-130%.

  17. Characterisation of polyacetylenes isolated from carrot (Daucus carota) extracts by negative ion tandem mass spectrometry.

    PubMed

    Rai, Dilip K; Brunton, Nigel P; Koidis, Anastasios; Rawson, Ashish; McLoughlin, Padraig; Griffiths, William J

    2011-08-15

    The potential use of negative electrospray ionisation mass spectrometry (ESI-MS) in the characterisation of the three polyacetylenes common in carrots (Daucus carota) has been assessed. The MS scans have demonstrated that the polyacetylenes undergo a modest degree of in-source decomposition in the negative ionisation mode while the positive ionisation mode has shown predominantly sodiated ions and no [M+H](+) ions. Tandem mass spectrometric (MS/MS) studies have shown that the polyacetylenes follow two distinct fragmentation pathways: one that involves cleavage of the C3-C4 bond and the other with cleavage of the C7-C8 bond. The cleavage of the C7-C8 bond generated product ions m/z 105.0 for falcarinol, m/z 105/107.0 for falcarindiol, m/z 147.0/149.1 for falcarindiol-3-acetate. In addition to these product ions, the transitions m/z 243.2 → 187.1 (falcarinol), m/z 259.2 → 203.1 (falcarindiol), m/z 301.2 → 255.2/203.1 (falcarindiol-3-acetate), mostly from the C3-C4 bond cleavage, can form the basis of multiple reaction monitoring (MRM)-quantitative methods which are poorly represented in the literature. The 'MS(3) ' experimental data confirmed a less pronounced homolytic cleavage site between the C11-C12 bond in the falcarinol-type polacetylenes. The optimised liquid chromatography (LC)/MS conditions have achieved a baseline chromatographic separation of the three polyacetylenes investigated within 40 min total run-time.

  18. A Machine Learning Based Approach to de novo Sequencing of Glycans from Tandem Mass Spectrometry Spectrum.

    PubMed

    Kumozaki, Shotaro; Sato, Kengo; Sakakibara, Yasubumi

    2015-01-01

    Recently, glycomics has been actively studied and various technologies for glycomics have been rapidly developed. Currently, tandem mass spectrometry (MS/MS) is one of the key experimental tools for identification of structures of oligosaccharides. MS/MS can observe MS/MS peaks of fragmented glycan ions including cross-ring ions resulting from internal cleavages, which provide valuable information to infer glycan structures. Thus, the aim of de novo sequencing of glycans is to find the most probable assignments of observed MS/MS peaks to glycan substructures without databases. However, there are few satisfiable algorithms for glycan de novo sequencing from MS/MS spectra. We present a machine learning based approach to de novo sequencing of glycans from MS/MS spectrum. First, we build a suitable model for the fragmentation of glycans including cross-ring ions, and implement a solver that employs Lagrangian relaxation with a dynamic programming technique. Then, to optimize scores for the algorithm, we introduce a machine learning technique called structured support vector machines that enable us to learn parameters including scores for cross-ring ions from training data, i.e., known glycan mass spectra. Furthermore, we implement additional constraints for core structures of well-known glycan types including N-linked glycans and O-linked glycans. This enables us to predict more accurate glycan structures if the glycan type of given spectra is known. Computational experiments show that our algorithm performs accurate de novo sequencing of glycans. The implementation of our algorithm and the datasets are available at http://glyfon.dna.bio.keio.ac.jp/. PMID:26671799

  19. Salivary Testosterone Measurement by Liquid Chromatography Tandem Mass Spectrometry in Adult Males and Females

    PubMed Central

    Keevil, BG; MacDonald, P; Macdowall, W; Lee, DM; Wu, FCW

    2016-01-01

    Background Salivary testosterone (Sal-T) may be a useful surrogate of serum free testosterone. The study aims were to use a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) assay to determine whether Sal-T concentrations accurately reflect Sal-T concentrations in both sexes and to investigate practical aspects of sample collection. Methods Saliva and serum samples were collected in 104 male and 91 female subjects. A more sensitive LC-MS/MS assay was developed to enable Sal-T quantitation in the low concentrations found in females. Saliva (200 μL) was extracted with 1 mL of methyl-tert-butyl ether following the addition of D5-testosterone. Quantitation was performed using a Waters TQ-S mass spectrometer. Results The assay achieved a lower limit of quantification of 5pmol/L, sufficiently sensitive to measure testosterone in female saliva. Sal-T showed a diurnal variation but samples taken at weekly and monthly intervals showed no significant differences. Sal-T was stable at ambient temperature for up to 5 days, after freeze-thawing and 3 years frozen storage. Reference intervals for Sal-T were 93-378 pmol/L in males and 5-46 pmol/L in females. Sal-T correlated significantly with serum calculated free-T in males (r=0.71, P<0.001) and in females (r=0.39, P<0.001). Conclusions These results confirm that testosterone can be reliably and accurately measured by LC-MS/MS in both adult male and female saliva samples. These results lay the foundation for further exploration of the clinical application of Sal- T as a reliable alternative to serum testosterone in the diagnosis and management of androgen disorders and assessment of androgen status in clinical research. PMID:24194586

  20. [Determination of aflatoxins in cashew by high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Bi, Ruifeng; Fan, Zhixian; Fu, Meng

    2011-12-01

    A method for the determination of four aflatoxins in cashew using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed. The sample was extracted with methanol-water (8: 2, v/v) solution, followed by a cleanup procedure with Florisil column. The target compounds were eluted using 5 mL acetone-water-formic acid (96: 3.5:0.5, v/v/v) solution. The eluate was dried under N2, then dissolved in 1 mL methanol. Four aflatoxins were separated in MG C18 column (100 mm x 3.0 mm, 3 microm) adopting a gradient program within 15 min. A triple quadrupole mass spectrometry equipped with an electrospray ionization source operated in the positive ion mode was used to detect the aflatoxins. The good correlation coefficients (r2 > 0.997) of the four aflatoxins were obtained within their respective linear ranges. The limits of detection (S/N = 3) were between 0.009 microg/kg and 0.04 microg/kg, and the limits of quantification (S/N = 10) were between 0.03 microg/kg and 0.12 microg/kg. The recoveries were in a range of 63.0% -78.5% with the relative standard deviations (RSDs) varied from 2.8% to 9.1%. The validation results meet the requirements of trace assay. Matrix effects were estimated and the signal suppression/enhancement ranged from 88.8% to 99.4%. The results indicate that the developed method is simple, fast, accurate, and can be applied for the determination of fours aflatoxins in cashew.

  1. An improved method for measuring metaldehyde in surface water using liquid chromatography tandem mass spectrometry

    PubMed Central

    Schumacher, Melanie; Castle, Glenn; Gravell, Anthony; Mills, Graham A.; Fones, Gary R.

    2016-01-01

    The molluscicide metaldehyde (2,4,6,8-tetramethyl-1,3,5,7-tetraoxocanemetacetaldehyde) is an emerging pollutant. It is frequently detected in surface waters, often above the European Community Drinking Water Directive limit of 0.1 μg/L for a single pesticide. Gas chromatography mass spectrometry (GC–MS) can be used to determine metaldehyde in environmental waters, but this method requires time consuming extraction techniques prior to instrumental analysis. Use of liquid chromatography-tandem mass spectrometry (LC–MS/MS) can overcome this problem. We describe a novel LC–MS/MS method, using a methylamine mobile phase additive, coupled with on-line sample enrichment that allows for the rapid and sensitive measurement of metaldehyde in surface water. Only the methylamine adduct of metaldehyde was formed with other unwanted alkali metal adducts and dimers being suppressed. As considerably less collision energy is required to fragment the methylamine adduct, a five-fold improvement in method sensitivity, compared to a previous method using an ammonium acetate buffer mobile phase was achieved. This new approach offers: • A validated method that meets regulatory requirements for the determination of metaldehyde in surface water. • Improved reliability of quantification over existing LC–MS/MS methods by using stable precursor ions for multiple reaction monitoring. • Low limits of quantification for tap water (4 ng/L) and river water (20 ng/L) using only 800 μL of sample; recoveries > 97%. PMID:27054094

  2. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

    SciTech Connect

    Winnik, Witold M. Kitchin, Kirk T.

    2008-11-15

    There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress.

  3. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS).

    PubMed

    Winnik, Witold M; Kitchin, Kirk T

    2008-11-15

    There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or fluorometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress. PMID:18547599

  4. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football

    PubMed Central

    Hart, Nicolas H.; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L.; Newton, Robert U.

    2016-01-01

    Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2) each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15) and inaccurate (n = 16) kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701). Relative lean mass was positively correlated with kicking accuracy (r = 0.631), while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083). Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy. Key points Accurate kickers expressed a very strong inverse relationship between leg mass and foot velocity. Inaccurate kickers were unable to replicate this, with greater volatility in their performance, indicating an ability of accurate kickers to mediate foot velocity to compensate for leg mass in order to deliver the ball over the required distance. Accurate kickers exhibited larger quantities of relative lean mass and lower

  5. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football.

    PubMed

    Hart, Nicolas H; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L; Newton, Robert U

    2016-06-01

    Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2) each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15) and inaccurate (n = 16) kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701). Relative lean mass was positively correlated with kicking accuracy (r = 0.631), while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083). Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy. Key pointsAccurate kickers expressed a very strong inverse relationship between leg mass and foot velocity. Inaccurate kickers were unable to replicate this, with greater volatility in their performance, indicating an ability of accurate kickers to mediate foot velocity to compensate for leg mass in order to deliver the ball over the required distance.Accurate kickers exhibited larger quantities of relative lean mass and lower quantities

  6. Relationship between Leg Mass, Leg Composition and Foot Velocity on Kicking Accuracy in Australian Football.

    PubMed

    Hart, Nicolas H; Nimphius, Sophia; Spiteri, Tania; Cochrane, Jodie L; Newton, Robert U

    2016-06-01

    Kicking a ball accurately over a desired distance to an intended target is arguably the most important skill to acquire in Australian Football. Therefore, understanding the potential mechanisms which underpin kicking accuracy is warranted. The aim of this study was to examine the relationship between leg mass, leg composition and foot velocity on kicking accuracy in Australian Football. Thirty-one Australian Footballers (n = 31; age: 22.1 ± 2.8 years; height: 1.81 ± 0.07 m; weight: 85.1 ± 13.0 kg; BMI: 25.9 ± 3.2) each performed ten drop punt kicks over twenty metres to a player target. Athletes were separated into accurate (n = 15) and inaccurate (n = 16) kicking groups. Leg mass characteristics were assessed using whole body DXA scans. Foot velocity was determined using a ten-camera optoelectronic, three-dimensional motion capture system. Interactions between leg mass and foot velocity evident within accurate kickers only (r = -0.670 to -0.701). Relative lean mass was positively correlated with kicking accuracy (r = 0.631), while no relationship between foot velocity and kicking accuracy was evident in isolation (r = -0.047 to -0.083). Given the evident importance of lean mass, and its interaction with foot velocity for accurate kickers; future research should explore speed-accuracy, impulse-variability, limb co-ordination and foot-ball interaction constructs in kicking using controlled with-in subject studies to examine the effects of resistance training and skill acquisition programs on the development of kicking accuracy. Key pointsAccurate kickers expressed a very strong inverse relationship between leg mass and foot velocity. Inaccurate kickers were unable to replicate this, with greater volatility in their performance, indicating an ability of accurate kickers to mediate foot velocity to compensate for leg mass in order to deliver the ball over the required distance.Accurate kickers exhibited larger quantities of relative lean mass and lower quantities

  7. Structural analysis of isomeric chondroitin sulfate oligosaccharides using regioselective 6-O-desulfation method and tandem mass spectrometry.

    PubMed

    Chen, Shu-Ting; Her, Guor-Rong

    2014-09-16

    A strategy based on a regioselective 6-O-desulfation reaction and negative ion electrospray ionization tandem mass spectrometry (ESI-MS(n)) was developed for the structural delineation of isomeric chondroitin sulfate oligosaccharides. Product ions resulting from the glycosidic cleavage provided information about the number of sulfate groups in each sugar residue. After the regioselective 6-O-desulfation reaction, the number of sulfate groups on each residue was obtained using a tandem mass spectrometry analysis of the reaction product. The sulfation pattern could be obtained based on the product ions of analytes before and after the desulfation reaction. The strategy was demonstrated using a series of tetrasaccharides prepared from shark cartilage chondroitin sulfate D. Among the 12 identified tetrasaccharides, six structures had not been reported before.

  8. Direct tandem mass spectrometric analysis of amino acids in plasma using fluorous derivatization and monolithic solid-phase purification.

    PubMed

    Tamashima, Erina; Hayama, Tadashi; Yoshida, Hideyuki; Imakyure, Osamu; Yamaguchi, Masatoshi; Nohta, Hitoshi

    2015-11-10

    In this study, we developed a novel direct tandem mass spectrometric method for rapid and accurate analysis of amino acids utilizing a fluorous derivatization and purification technique. Amino acids were perfluoroalkylated with 2H,2H,3H,3H-perfluoroundecan-1-al in the presence of 2-picoline borane via reductive amination. The derivatives were purified by perfluoroalkyl-modified silica-based monolithic solid-phase extraction (monolithic F-SPE), and directly analyzed by tandem mass spectrometry using electrospray ionization without liquid chromatographic separation. The perfluoroalkyl derivatives could be sufficiently distinguished from non-fluorous compounds, i.e. the biological matrix, due to their fluorous interaction. Thus, rapid and accurate determination of amino acids was accomplished. The method was validated with human plasma samples and applied to the analysis of amino acids in the plasma of mice with maple syrup urine disease or phenylketonuria. PMID:26222276

  9. Direct tandem mass spectrometric analysis of amino acids in plasma using fluorous derivatization and monolithic solid-phase purification.

    PubMed

    Tamashima, Erina; Hayama, Tadashi; Yoshida, Hideyuki; Imakyure, Osamu; Yamaguchi, Masatoshi; Nohta, Hitoshi

    2015-11-10

    In this study, we developed a novel direct tandem mass spectrometric method for rapid and accurate analysis of amino acids utilizing a fluorous derivatization and purification technique. Amino acids were perfluoroalkylated with 2H,2H,3H,3H-perfluoroundecan-1-al in the presence of 2-picoline borane via reductive amination. The derivatives were purified by perfluoroalkyl-modified silica-based monolithic solid-phase extraction (monolithic F-SPE), and directly analyzed by tandem mass spectrometry using electrospray ionization without liquid chromatographic separation. The perfluoroalkyl derivatives could be sufficiently distinguished from non-fluorous compounds, i.e. the biological matrix, due to their fluorous interaction. Thus, rapid and accurate determination of amino acids was accomplished. The method was validated with human plasma samples and applied to the analysis of amino acids in the plasma of mice with maple syrup urine disease or phenylketonuria.

  10. A simple algorithm improves mass accuracy to 50-100 ppm for delayed extraction linear MALDI-TOF mass spectrometry

    SciTech Connect

    Hack, Christopher A.; Benner, W. Henry

    2001-10-31

    A simple mathematical technique for improving mass calibration accuracy of linear delayed extraction matrix assisted laser desorption ionization time-of-flight mass spectrometry (DE MALDI-TOF MS) spectra is presented. The method involves fitting a parabola to a plot of Dm vs. mass data where Dm is the difference between the theoretical mass of calibrants and the mass obtained from a linear relationship between the square root of m/z and ion time of flight. The quadratic equation that describes the parabola is then used to correct the mass of unknowns by subtracting the deviation predicted by the quadratic equation from measured data. By subtracting the value of the parabola at each mass from the calibrated data, the accuracy of mass data points can be improved by factors of 10 or more. This method produces highly similar results whether or not initial ion velocity is accounted for in the calibration equation; consequently, there is no need to depend on that uncertain parameter when using the quadratic correction. This method can be used to correct the internally calibrated masses of protein digest peaks. The effect of nitrocellulose as a matrix additive is also briefly discussed, and it is shown that using nitrocellulose as an additive to a CHCA matrix does not significantly change initial ion velocity but does change the average position of ions relative to the sample electrode at the instant the extraction voltage is applied.

  11. Simultaneous analysis of mono-, di-, and tri-ethanolamine in cosmetic products using liquid chromatography coupled tandem mass spectrometry.

    PubMed

    Shin, Kyong-Oh; Lee, Yong-Moon

    2016-01-01

    Alkanolamines such as monoethanolamine (MEA), diethanolamine (DEA), and triethanolamine (TEA) are used as wetting agents in shampoos, lotions, creams, and other cosmetics. DEA is widely used to provide lather in shampoos and maintain a favorable consistency in lotions and creams. Although DEA is not harmful, it may react with other ingredients in the cosmetic formula after extended storage periods to form an extremely potent carcinogen called nitrosodiethanolamine (NDEA), which is readily absorbed through the skin and has been linked to the development of stomach, esophagus, liver, and bladder cancers. The purpose of this study was to develop a simultaneous quantification method for measurement of MEA, DEA, and TEA in cosmetic products. Liquid chromatography coupled tandem mass spectrometry (LC-MS/MS) was performed using a hydrophilic interaction liquid chromatography (HILIC) column with isocratic elution containing acetonitrile and 5 mM ammonium formate in water (88:12, v/v). Identification and quantification of alkanolamines were performed using MS/MS monitoring to assess the transition from precursor to product ion of MEA (m/z, 61.1 → 44.0), DEA (m/z, 106.1 → 88.0), TEA (m/z, 150.1 → 130.0), and the internal standard triethylamine (m/z, 102.2 → 58.0). Alkanolamines extractions were simplified using a single extraction with acetonitrile in the cosmetic matrix. Performance of the method was evaluated with quality parameters such as specificity, carry-over, linearity and calibration, correlation of determination (R(2)), detection limit, precision, accuracy, and recovery. Calibration curves of MEA (2.9-1000 ppb), DEA (1-1000 ppb), and TEA (1-1000 ppb) were constructed by plotting concentration versus peak-area ratio (analyte/internal standard with a correlation coefficient greater than 0.99). The intra- and inter-assay accuracy ranged from 92.92 to 101.15 % for all analytes. The intra- and inter-assay precision for MEA, DEA, and TEA showed all

  12. Rapid determination of benzodiazepines, zolpidem and their metabolites in urine using direct injection liquid chromatography-tandem mass spectrometry.

    PubMed

    Jeong, Yu-Dong; Kim, Min Kyung; Suh, Sung Ill; In, Moon Kyo; Kim, Jin Young; Paeng, Ki-Jung

    2015-12-01

    Benzodiazepines and zolpidem are generally prescribed as sedative, hypnotics, anxiolytics or anticonvulsants. These drugs, however, are frequently misused in drug-facilitated crime. Therefore, a rapid and simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of benzodiazepines, zolpidem and their metabolites in urine using deuterium labeled internal standards (IS). Urine samples (120 μL) mixed with 80 μL of the IS solution were centrifuged. An aliquot (5 μL) of the sample solution was directly injected into the LC-MS/MS system for analysis. The mobile phases consisted of water and acetonitrile containing 2mM ammonium trifluoroacetate and 0.2% acetic acid. The analytical column was a Zorbax SB-C18 (100 mm × 2.1 mm i.d., 3.5 μm, Agilent). The separation and detection of 18 analytes were achieved within 10 min. Calibration curves were linear over the concentration ranges of 0.5-20 ng/mL (zolpidem), 1.0-40 ng/mL (flurazepam and temazepam), 2.5-100 ng/mL (7-aminoclonazepam, 1-hydroxymidazolam, midazolam, flunitrazepam and alprazolam), 5.0-200 ng/mL (zolpidem phenyl-4-carboxylic acid, α-hydroxyalprazolam, oxazepam, nordiazepam, triazolam, diazepam and α-hydroxytriazolam), 10-400 ng/mL (lorazepam and desalkylflurazepam) and 10-100 ng/mL (N-desmethylflunitrazepam) with the coefficients of determination (r(2)) above 0.9971. The dilution integrity of the analytes was examined for supplementation of short linear range. Dilution precision and accuracy were tested using two, four and ten-folds dilutions and they ranged from 3.7 to 14.4% and -12.8 to 12.5%, respectively. The process efficiency for this method was 63.0-104.6%. Intra- and inter-day precisions were less than 11.8% and 9.1%, while intra- and inter-day accuracies were less than -10.0 to 8.2%, respectively. The lower limits of quantification were lower than 10 ng/mL for each analyte. The applicability of the developed method was successfully

  13. Simultaneous determination of four alkaloids in Lindera aggregata by ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang

    2008-11-28

    A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.

  14. Binomial probability distribution model-based protein identification algorithm for tandem mass spectrometry utilizing peak intensity information.

    PubMed

    Xiao, Chuan-Le; Chen, Xiao-Zhou; Du, Yang-Li; Sun, Xuesong; Zhang, Gong; He, Qing-Yu

    2013-01-01

    Mass spectrometry has become one of the most important technologies in proteomic analysis. Tandem mass spectrometry (LC-MS/MS) is a major tool for the analysis of peptide mixtures from protein samples. The key step of MS data processing is the identification of peptides from experimental spectra by searching public sequence databases. Although a number of algorithms to identify peptides from MS/MS data have been already proposed, e.g. Sequest, OMSSA, X!Tandem, Mascot, etc., they are mainly based on statistical models considering only peak-matches between experimental and theoretical spectra, but not peak intensity information. Moreover, different algorithms gave different results from the same MS data, implying their probable incompleteness and questionable reproducibility. We developed a novel peptide identification algorithm, ProVerB, based on a binomial probability distribution model of protein tandem mass spectrometry combined with a new scoring function, making full use of peak intensity information and, thus, enhancing the ability of identification. Compared with Mascot, Sequest, and SQID, ProVerB identified significantly more peptides from LC-MS/MS data sets than the current algorithms at 1% False Discovery Rate (FDR) and provided more confident peptide identifications. ProVerB is also compatible with various platforms and experimental data sets, showing its robustness and versatility. The open-source program ProVerB is available at http://bioinformatics.jnu.edu.cn/software/proverb/ .

  15. Dynamic Modeling Accuracy Dependence on Errors in Sensor Measurements, Mass Properties, and Aircraft Geometry

    NASA Technical Reports Server (NTRS)

    Grauer, Jared A.; Morelli, Eugene A.

    2013-01-01

    A nonlinear simulation of the NASA Generic Transport Model was used to investigate the effects of errors in sensor measurements, mass properties, and aircraft geometry on the accuracy of dynamic models identified from flight data. Measurements from a typical system identification maneuver were systematically and progressively deteriorated and then used to estimate stability and control derivatives within a Monte Carlo analysis. Based on the results, recommendations were provided for maximum allowable errors in sensor measurements, mass properties, and aircraft geometry to achieve desired levels of dynamic modeling accuracy. Results using other flight conditions, parameter estimation methods, and a full-scale F-16 nonlinear aircraft simulation were compared with these recommendations.

  16. Identification of unknown impurities in simvastatin substance and tablets by liquid chromatography/tandem mass spectrometry.

    PubMed

    Vuletić, Marko; Cindrić, Mario; Koruznjak, Jasna Dogan

    2005-04-01

    Unknown impurities were detected in simvastatin substance and tablets at a 0.2% level using the liquid chromatography technique with UV (DAD) detection. The impurity structures were elucidated by a direct hyphenation of liquid chromatograph to high-resolution mass spectrometer with electrospray ionisation interface using solutions of formic acid in water and in acetonitrile as the mobile phase. Peak tracking was performed using the column-switching technique. Accurate mass measurements by quadrupole time-of-flight mass spectrometer equipped with lock-spray provided information about elemental composition of intact molecules and fragments of impurities. Measurement accuracy for precursor ions was around 3 ppm and for fragment ions between 4 and 13 ppm. Mass resolving power was around 6500. Deduced molecular formulae for A1, A2 and A3 impurities were C(27)H(44)O(6), C(26)H(43)O(6) and C(26)H(41)O(5), respectively. The structures proposed for all three impurities revealed modifications of simvastatin molecule on the lactone ring. Impurity A1, detected in simvastatin tablets, was identified as ethyl ester, while the impurities A2 and A3, detected in simvastatin substance, were identified as methyl ester and methyl ether of simvastatin. The impurity from tablets was synthesized and its structure confirmed by LC-UV, LC-MS/MS, and NMR techniques.

  17. Improved 6-Plex Tandem Mass Tags Quantification Throughput Using a Linear Ion Trap-High-Energy Collision Induced Dissociation MS(3) Scan.

    PubMed

    Liu, Jane M; Sweredoski, Michael J; Hess, Sonja

    2016-08-01

    The use of tandem mass tags (TMT) as an isobaric labeling strategy is a powerful method for quantitative proteomics, yet its accuracy has traditionally suffered from interference. This interference can be largely overcome by selecting MS(2) fragment precursor ions for high-energy collision induced dissociation (HCD) MS(3) analysis in an Orbitrap scan. While this approach minimizes the interference effect, sensitivity suffers due to the high AGC targets and long acquisition times associated with MS(3) Orbitrap detection. We investigated whether acquiring the MS(3) scan in a linear ion trap with its lower AGC target would increase overall quantification levels with a minimal effect on precision and accuracy. Trypsin-digested proteins from Saccharomyces cerevisiae were tagged with 6-plex TMT reagents. The sample was subjected to replicate analyses using either the Orbitrap or the linear ion trap for the HCD MS(3) scan. HCD MS(3) detection in the linear ion trap vs Orbitrap increased protein identification by 66% with minor loss in precision and accuracy. Thus, the use of a linear ion trap-HCD MS(3) scan during a 6-plex TMT experiment can improve overall identification levels while maintaining the power of multiplexed quantitative analysis. PMID:27377715

  18. Validation of a tandem mass spectrometry method using combined extraction of 37 oxylipins and 14 endocannabinoid-related compounds including prostamides from biological matrices.

    PubMed

    Gouveia-Figueira, Sandra; Nording, Malin L

    2015-09-01

    There is a clinical need for more relevant coverage of bioactive lipids using smaller sample volumes. Therefore, we have validated a tandem mass spectrometry method for combined solid phase extraction of 37 compounds in the oxylipin (OxL) and 14 in the endocannabinoid (eCB) metabolome, as well as prostamides. The limits of quantification (LOQ) for compounds in the eCB metabolome were in the range 0.5-1000 fg on column, intraday accuracy and precision ranges (%) were 83-125 and 0.3-17, respectively, and interday accuracy and precision ranges (%) were 80-119 and 1.2-20, respectively, dependent upon the compound and the concentration studied. Corresponding values for OxL were 0.5 fg-4.2 pg on column (LOQ), 85-115% (inter- and intraday accuracy) and <5% (precision). The combined extraction method was successfully applied to tissues, cell extracts, human plasma and milk samples. A deeper study of levels in elk, pig and cow brain, as well as cow heart and liver revealed tissue and species-specific elevation of eicosanoids: arachidonate diols, 20-HETE and 12(S)-HEPE (cow liver), LTB4 (cow brain), and monohydroxy metabolites (HETEs), epoxides and 5-oxo-ETE in elk brain, which might be caused by factors of stress and/or post-mortem reactions in the tissues. PMID:26115647

  19. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  20. Mass spectral study of alkali-cationized Boc-carbo-beta3-peptides by electrospray tandem mass spectrometry.

    PubMed

    Srikanth, R; Reddy, P Nagi; Srinivas, R; Sharma, G V M; Reddy, K Ravinder; Krishna, Palakodety Radha

    2004-01-01

    Electrospray tandem mass spectrometry was used to study the dissociation reactions of [M+Cat]+ (Cat = Na+ and Li+) of Boc-carbo-beta3-peptides. The collision-induced dissociation (CID) spectra of [M+Cat-Boc]+ of these peptides are found to be significantly different from those of [M+H-Boc]+ ions. The spectra are more informative and display both C- and N-terminus metallated ions in addition to characteristic fragment ions of the carbohydrate moiety. Based on the fragmentations observed in the CID spectra of the [M+Cat-Boc]+ ions, it is suggested that the dissociation involves complexes in which the metal ion is coordinated in a multidentate arrangement involving the carbonyl oxygen atoms. The CID spectra of [M+Cat-Boc]+ ions of the peptide acids show an abundant N-terminal rearrangement ion [b(n)+17+Cat]+ which is absent for esters. Further, two pairs of positionally isomeric Boc-carbo-beta3-peptide acids, Boc-NH-Caa(S)-beta-hGly-OH (11) and Boc-NH-beta-hGly-Caa(S)-OH (12), and [Boc-NH-Caa(S)-beta-hGly-Caa(S)-beta-hGly-OH] (13) and [Boc-NH-beta-hGly-Caa(S)-beta-hGly-Caa(S)-OH] (14), were differentiated by the CID of [M+Cat-Boc]+ ions. The CID spectra of compounds 11 and 13 are significantly different from those of 12 and 14, respectively. The abundance of [b(n)+17+Cat]+ ions is higher for peptide acids 12 and 14 with a sugar group at the C-terminus when compared to 11 and 13 which contain a sugar moiety at the N-terminus. The observed differences between the CID spectra of these isomeric peptides are attributed to the difference in the preferential site of metal ion binding and also on the structure of the cyclic intermediate involved in the formation of the rearrangement ion.

  1. Detection and identification of alkylphosphonic acids by positive electrospray ionization tandem mass spectrometry using a tricationic reagent.

    PubMed

    Tak, Vijay; Pardasani, Deepak; Purohit, Ajay; Dubey, D K

    2011-11-30

    The retrospective detection and identification of degradation products of chemical warfare agents are of immense importance in order to prove their spillage and use. A highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method--using an imidazolium-based tricationic reagent--was developed for the detection and identification of the anionic degradation products of nerve agents. A commercially available solution of 1,3-imidazolium-bis-(1-hexylbenzylimidazolium) trifluoride (IBHBI) formed adducts with alkylphosphonic acids (APAs), allowing detection of the APAs by positive mode ESI-MS. Tandem mass spectrometry was used for the unambiguous identification of the APAs. Parameters influencing the formation and stability of these adduct during mass spectrometric analysis, such as solvent composition, concentration of IBHBI, effect of pH and interferences by salts, were optimized. The absolute limits of detection (0.1 ng) for achieved for the APAs were better than those previously reported, and linear dynamic ranges of 10-2000 ng mL(-1) were achieved. The method was repeatable with a relative standard deviation ≤7.3%. APAs present in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during the 22(nd) and 24(th) Official Proficiency tests were detected and identified as IBHBI adducts. The added advantage of this method is that low-mass analytes are detected at higher mass, thus obviating the problem with background noise at low mass. PMID:22002694

  2. Identification and quantification of ricin in biomedical samples by magnetic immunocapture enrichment and liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Ma, Xiaoxi; Tang, Jijun; Li, Chunzheng; Liu, Qin; Chen, Jia; Li, Hua; Guo, Lei; Xie, Jianwei

    2014-08-01

    Ricin is a toxic protein derived from castor beans and composed of a cytotoxic A chain and a galactose-binding B chain linked by a disulfide bond, which can inhibit protein synthesis and cause cell death. Owing to its high toxicity, ease of preparation, and lack of medical countermeasures, ricin has been listed as both chemical and biological warfare agents. For homeland security or public safety, the unambiguous, sensitive, and rapid methods for identification and quantification of ricin in complicated matrices are of urgent need. Mass spectrometric analysis, which provides specific and sensitive characterization of protein, can be applied to confirm and quantify ricin. Here, we report a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method in which ricin was extracted and enriched from serum by immunocapture using anti-ricin monoclonal antibody 3D74 linked to magnetic beads, then digested by trypsin, and analyzed by LC-ESI-MS/MS. Among 19 distinct peptides observed in LC-quadrupole/time of flight-MS (LC-QTOF-MS), two specific and sensitive peptides, T7A ((49)VGLPINQR(56)) and T14B ((188)DNCLTSDSNIR(198)), were chosen, and a highly sensitive determination of ricin was established in LC-triple quadrupole-MS (LC-QqQ-MS) operating in multiple reaction monitoring mode. These specific peptides can definitely distinguish ricin from the homologous protein Ricinus communis agglutinin (RCA120), even though the amino acid sequence homology of the A-chain of ricin and RCA120 is up to ca. 93% and that of B-chain is ca. 85%. Furthermore, peptide T7A was preferred in the quantification of ricin because its sensitivity was at least one order of magnitude higher than that of the peptide T14B. Combined with immunocapture enrichment, this method provided a limit of detection of ca. 2.5 ng/mL and the limit of quantification was ca. 5 ng/mL of ricin in serum, respectively. Both precision and accuracy of this method were determined and the RSD

  3. Identification and quantification of ricin in biomedical samples by magnetic immunocapture enrichment and liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Ma, Xiaoxi; Tang, Jijun; Li, Chunzheng; Liu, Qin; Chen, Jia; Li, Hua; Guo, Lei; Xie, Jianwei

    2014-08-01

    Ricin is a toxic protein derived from castor beans and composed of a cytotoxic A chain and a galactose-binding B chain linked by a disulfide bond, which can inhibit protein synthesis and cause cell death. Owing to its high toxicity, ease of preparation, and lack of medical countermeasures, ricin has been listed as both chemical and biological warfare agents. For homeland security or public safety, the unambiguous, sensitive, and rapid methods for identification and quantification of ricin in complicated matrices are of urgent need. Mass spectrometric analysis, which provides specific and sensitive characterization of protein, can be applied to confirm and quantify ricin. Here, we report a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method in which ricin was extracted and enriched from serum by immunocapture using anti-ricin monoclonal antibody 3D74 linked to magnetic beads, then digested by trypsin, and analyzed by LC-ESI-MS/MS. Among 19 distinct peptides observed in LC-quadrupole/time of flight-MS (LC-QTOF-MS), two specific and sensitive peptides, T7A ((49)VGLPINQR(56)) and T14B ((188)DNCLTSDSNIR(198)), were chosen, and a highly sensitive determination of ricin was established in LC-triple quadrupole-MS (LC-QqQ-MS) operating in multiple reaction monitoring mode. These specific peptides can definitely distinguish ricin from the homologous protein Ricinus communis agglutinin (RCA120), even though the amino acid sequence homology of the A-chain of ricin and RCA120 is up to ca. 93% and that of B-chain is ca. 85%. Furthermore, peptide T7A was preferred in the quantification of ricin because its sensitivity was at least one order of magnitude higher than that of the peptide T14B. Combined with immunocapture enrichment, this method provided a limit of detection of ca. 2.5 ng/mL and the limit of quantification was ca. 5 ng/mL of ricin in serum, respectively. Both precision and accuracy of this method were determined and the RSD

  4. Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry

    PubMed Central

    Faqehi, Abdullah M.M.; Cobice, Diego F.; Naredo, Gregorio; Mak, Tracy C.S.; Upreti, Rita; Gibb, Fraser W.; Beckett, Geoffrey J.; Walker, Brian R.; Homer, Natalie Z.M.; Andrew, Ruth

    2016-01-01

    Estrogens circulate at concentrations less than 20 pg/mL in men and postmenopausal women, presenting analytical challenges. Quantitation by immunoassay is unreliable at these low concentrations. Liquid chromatography tandem mass spectrometry (LC–MS/MS) offers greater specificity and sometimes greater sensitivity, but ionization of estrogens is inefficient. Introduction of charged moieties may enhance ionization, but many such derivatives of estrogens generate non-specific product ions originating from the “reagent” group. Therefore an approach generating derivatives with product ions specific to individual estrogens was sought. Estrogens were extracted from human plasma and serum using solid phase extraction and derivatized using 2-fluoro-1-methylpyridinium-p-toluenesulfonate (FMP-TS). Electrospray in positive mode with multiple reaction monitoring using a QTrap 5500 mass spectrometer was used to quantify “FMP” derivatives of estrogens, following LC separation. Transitions for the FMP derivatives of estrone (E1) and estradiol (E2) were compound specific (m/z 362→238 and m/z 364→128, respectively). The limits of detection and quantitation were 0.2 pg on-column and the method was linear from 1–400 pg/sample. Measures of intra- and inter-assay variability, precision and accuracy were acceptable (<20%). The derivatives were stable over 24 h at 10 °C (7–9% degradation). Using this approach, E1 and E2, respectively were detected in human plasma and serum: pre-menopausal female serum (0.5 mL) 135–473, 193–722 pmol/L; male plasma (1 mL) 25–111, 60–180 pmol/L and post-menopausal female plasma (2 mL), 22–78, 29–50 pmol/L. Thus FMP derivatization, in conjunction with LC–MS/MS, is suitable for quantitative analysis of estrogens in low abundance in plasma and serum, offering advantages in specificity over immunoassay and existing MS techniques. PMID:26946022

  5. Identification of glutamic acid 78 as the active site nucleophile in Bacillus subtilis xylanase using electrospray tandem mass spectrometry.

    PubMed

    Miao, S; Ziser, L; Aebersold, R; Withers, S G

    1994-06-14

    A new mechanism-based inactivator of beta-1,4-xylanases, 2',4'-dinitrophenyl 2-deoxy-2-fluoro-beta-xylobioside, has been synthesized and used to trap the covalent intermediate formed during catalysis by Bacillus subtilis xylanase. Electrospray mass spectrometry confirmed the 1:1 stoichiometry of the incorporation of inactivator into the enzyme. Inactivation of xylanase followed the expected pseudo-first-order kinetic behavior, and kinetic parameters were determined. The intermediate trapped was relatively stable toward hydrolytic turnover (t1/2 = 350 min). However, turnover could be facilitated by transglycosylation following the addition of the acceptor benzyl thio-beta-xylobioside, thus demonstrating the catalytic competence of the trapped intermediate. Reactivation kinetic parameters for this process of kre = 0.03 min-1 and Kre = 46 mM were determined. The nucleophilic amino acid was identified as Glu78 by a tandem mass spectrometric technique which does not require the use of radiolabels. The peptic digest of the labeled enzyme was separated by high-performance liquid chromatography and the eluent fed into a tandem mass spectrometer via an electrospray ionization device. The labeled peptide was identified as one of m/z = 826 (doubly charged) which fragmented in the collision chamber between the mass analyzers with loss of the mass of a 2-fluoroxylobiosyl unit. Confirmation of the peptide identity was obtained both by tandem mass spectrometric sequencing and by Edman degradation of the purified peptide. Glu78 is completely conserved in all members of this xylanase family and indeed is shown to be located in the active site in the recently determined X-ray crystal structure.

  6. Chemical modification of proteins to improve the accuracy of their relative molecular mass determination by electrophoresis.

    PubMed

    Dolnik, Vladislav; Gurske, William A

    2011-10-01

    We studied the electrophoretic behavior of basic proteins (cytochrome c and histone III) and developed a carbamylation method that normalizes their electrophoretic size separation and improves the accuracy of their relative molecular mass determined electrophoretically. In capillary zone electrophoresis with cationic hitchhiking, native cytochrome c does not sufficiently bind cationic surfactants due to electrostatic repulsion between the basic protein and cationic surfactant. Carbamylation suppresses the strong positive charge of the basic proteins and results in more accurate relative molecular masses.

  7. Anion exchange SPE and liquid chromatography-tandem mass spectrometry in GHB analysis.

    PubMed

    Elian, Albert A; Hackett, Jeffery

    2011-12-01

    In this study, the extraction of γ-hydroxybutyrate (GHB) from urine using solid-phase extraction (SPE) is described. SPE was performed on anion exchange columns after samples of urine had been diluted with de-ionized water. After application of the diluted samples containing GHB-d(6) as an internal standard, the sorbent was washed with deionized water and methanol and dried. The GHB was eluted from the SPE column with a solvent consisting of methanol containing 6% glacial acetic acid. The eluent was collected, evaporated to dryness, and dissolved in mobile phase (100 μL) for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative multiple reaction monitoring (MRM) mode. Liquid chromatography was performed in gradient mode employing a biphenyl column and a mobile phase consisting of acetontitrile (containing 0.1% formic acid) and 0.1% aqueous formic acid. The total run time for each analysis was less than 5 min. The limits of detection/quantification for this method were determined to be 50 and 100 ng/mL, respectively. The method was found to be linear from 500 ng/mL to 10,000 ng/mL (r(2)>0.995). The recovery of GHB was found to be greater than 75%. In this report, results of authentic urine samples analyzed for GHB by this method are presented. GHB concentrations in these samples were found to be range from less than 500 ng/mL to 5110 ng/mL.

  8. Nitroproteins in Human Astrocytomas Discovered by Gel Electrophoresis and Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Peng, Fang; Li, Jianglin; Guo, Tianyao; Yang, Haiyan; Li, Maoyu; Sang, Shushan; Li, Xuejun; Desiderio, Dominic M.; Zhan, Xianquan

    2015-12-01

    Protein tyrosine nitration is involved in the pathogenesis of highly fatal astrocytomas, a type of brain cancer. To understand the molecular mechanisms of astrocytomas and to discover new biomarkers/therapeutic targets, we sought to identify nitroproteins in human astrocytoma tissue. Anti-nitrotyrosine immunoreaction-positive proteins from a high-grade astrocytoma tissue were detected with two-dimensional gel electrophoresis (2DGE)-based nitrotyrosine immunoblots, and identified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Fifty-seven nitrotyrosine immunopositive protein spots were detected. A total of 870 proteins (nitrated and non-nitrated) in nitrotyrosine-immunopositive 2D gel spots were identified, and 18 nitroproteins and their 20 nitrotyrosine sites were identified with MS/MS analysis. These nitroproteins participate in multiple processes, including drug-resistance, signal transduction, cytoskeleton, transcription and translation, cell proliferation and apoptosis, immune response, phenotypic dedifferentiation, cell migration, and metastasis. Among those nitroproteins that might play a role in astrocytomas was nitro-sorcin, which is involved in drug resistance and metastasis and might play a role in the spread and treatment of an astrocytoma. Semiquantitative immune-based measurements of different sorcin expressions were found among different grades of astrocytomas relative to controls, and a semiquantitative increased nitration level in high-grade astrocytoma relative to control. Nitro-β-tubulin functions in cytoskeleton and cell migration. Semiquantitative immunoreactivity of β-tubulin showed increased expression among different grades of astrocytomas relative to controls and semiquantitatively increased nitration level in high-grade astrocytoma relative to control. Each nitroprotein was rationalized and related to the corresponding functional system to provide new insights into tyrosine nitration and its potential role in the

  9. Quantification of six cannabinoids and metabolites in oral fluid by liquid chromatography-tandem mass spectrometry.

    PubMed

    Desrosiers, Nathalie A; Scheidweiler, Karl B; Huestis, Marilyn A

    2015-08-01

    Δ(9) -Tetrahydrocannabinol (THC) is the most commonly analyzed cannabinoid in oral fluid (OF); however, its metabolite 11-nor-9-carboxy-THC (THCCOOH) offers the advantage of documenting active consumption, as it is not detected in cannabis smoke. Analytical challenges such as low (ng/L) THCCOOH OF concentrations hampered routine OF THCCOOH monitoring. Presence of minor cannabinoids like cannabidiol and cannabinol offer the advantage of identifying recent cannabis intake. Published OF cannabinoids methods have limitations, including few analytes and lengthy derivatization. We developed and validated a sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for THC, its metabolites, 11-hydroxy-THC and THCCOOH quantification, and other natural cannabinoids including tetrahydrocannabivarin (THCV), cannabidiol (CBD), and cannabigerol (CBG) in 1 mL OF collected with the Quantisal device. After solid-phase extraction, chromatography was performed on a Selectra PFPP column with a 0.15% formic acid in water and acetonitrile gradient with a 0.5 mL/min flow rate. All analytes were monitored in positive mode atmospheric pressure chemical ionization (APCI) with multiple reaction monitoring. Limits of quantification were 15 ng/L THCCOOH and 0.2 µg/L for all other analytes. Linear ranges extended to 3750 ng/L THCCOOH, 100 µg/L THC, and 50 µg/L for all other analytes. Inter-day analytical recoveries (bias) and imprecision at low, mid, and high quality control (QC) concentrations were 88.7-107.3% and 2.3-6.7%, respectively (n = 20). Mean extraction efficiencies and matrix effects evaluated at low and high QC were 75.9-86.1% and 8.4-99.4%, respectively. This method will be highly useful for workplace, criminal justice, drug treatment and driving under the influence of cannabis OF testing. PMID:25428610

  10. [Determination of five pyrrolizidine alkaloids in honey by liquid chromatography-tandem mass spectrometry].

    PubMed

    Lü, Chen; Ding, Tao; Ma, Xin; Chen, Guosong; Yuan, Fang; Wu, Bin; Shen, Chongyu; Zhang, Rui; Fei, Xiaoqing; Zhang, Xiaoyan; Chen, Lei; Li, Li

    2013-11-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of five pyrrolizidine alkaloids (PAs) (monocrotaline, senkirkine, retrorsine, seneciphylline and senecionine) in honey. The honey samples were dissolved in 0.1 mol/L hydrochloric acid solution and a strong-cation exchange column was used to purify and concentrate the target analytes. The separation of the analytes was carried out on a Phenomenex C18 column (100 mm x 4.6 mm, 2.6 microm) using the mobile phases of acetonitrile and 5 mmol/L ammonium acetate-0.1% (volume percentage) formic acid aqueous solution with gradient elution. The separated compounds were detected in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI+). The calibration curves were of good linearity in the range of 1-100 microg/L (r > 0.99). The limit of quantification of the method was 1.0 microg/kg. The average recoveries were between 73.1% to 107.1% at three spiked levels (1, 20 and 50 microg/kg) with the relative standard deviations (RSDs) in the range of 4.1% to 17.0%. The proposed method was applied to different kinds of honey from China, New Zealand, Spain and Australia. The samples included rape, vitex, sunflower, cotton, tilia tree, date, acacia, buckwheat, manuka and eucalyptus honey. Monocrotaline, senkirkine and retrorsine were not detected in the collected honey samples. However, seneciphylline and senecionine were found in most of the honey samples. The concentrations of seneciphylline and senecionine were 11.0 -31.1 microg/kg and 8.3-29.1 microg/kg, respectively.

  11. Quantification of six cannabinoids and metabolites in oral fluid by liquid chromatography-tandem mass spectrometry.

    PubMed

    Desrosiers, Nathalie A; Scheidweiler, Karl B; Huestis, Marilyn A

    2015-08-01

    Δ(9) -Tetrahydrocannabinol (THC) is the most commonly analyzed cannabinoid in oral fluid (OF); however, its metabolite 11-nor-9-carboxy-THC (THCCOOH) offers the advantage of documenting active consumption, as it is not detected in cannabis smoke. Analytical challenges such as low (ng/L) THCCOOH OF concentrations hampered routine OF THCCOOH monitoring. Presence of minor cannabinoids like cannabidiol and cannabinol offer the advantage of identifying recent cannabis intake. Published OF cannabinoids methods have limitations, including few analytes and lengthy derivatization. We developed and validated a sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for THC, its metabolites, 11-hydroxy-THC and THCCOOH quantification, and other natural cannabinoids including tetrahydrocannabivarin (THCV), cannabidiol (CBD), and cannabigerol (CBG) in 1 mL OF collected with the Quantisal device. After solid-phase extraction, chromatography was performed on a Selectra PFPP column with a 0.15% formic acid in water and acetonitrile gradient with a 0.5 mL/min flow rate. All analytes were monitored in positive mode atmospheric pressure chemical ionization (APCI) with multiple reaction monitoring. Limits of quantification were 15 ng/L THCCOOH and 0.2 µg/L for all other analytes. Linear ranges extended to 3750 ng/L THCCOOH, 100 µg/L THC, and 50 µg/L for all other analytes. Inter-day analytical recoveries (bias) and imprecision at low, mid, and high quality control (QC) concentrations were 88.7-107.3% and 2.3-6.7%, respectively (n = 20). Mean extraction efficiencies and matrix effects evaluated at low and high QC were 75.9-86.1% and 8.4-99.4%, respectively. This method will be highly useful for workplace, criminal justice, drug treatment and driving under the influence of cannabis OF testing.

  12. Validation of keratan sulfate level in mucopolysaccharidosis type IVA by liquid chromatography-tandem mass spectrometry.

    PubMed

    Tomatsu, Shunji; Montaño, Adriana M; Oguma, Toshihiro; Dung, Vu Chi; Oikawa, Hirotaka; de Carvalho, Talita Giacomet; Gutiérrez, María L; Yamaguchi, Seiji; Suzuki, Yasuyuki; Fukushi, Masaru; Kida, Kazuhiro; Kubota, Mitsuru; Barrera, Luis; Orii, Tadao

    2010-12-01

    Mucopolysaccharidosis type IVA (MPS IVA, Morquio A disease), a progressive lysosomal storage disease, causes skeletal chondrodysplasia through excessive storage of keratan sulfate (KS). KS is synthesized mainly in cartilage and released to the circulation. The excess storage of KS disrupts cartilage, consequently releasing more KS into circulation, which is a critical biomarker for MPS IVA. Thus, assessment of KS level provides a potential screening strategy and determines clinical course and efficacy of therapies. We have recently developed a tandem mass spectrometry liquid chromatography [LC/MS/MS] method to assay KS levels in blood. Forty-nine blood specimens from patients with MPS IVA [severe (n = 33), attenuated (n = 11) and undefined (n = 5)] were analyzed for comparison of blood KS concentration with that of healthy subjects and for correlation with clinical severity. Plasma samples were digested by keratanase II to obtain disaccharides of KS. Digested samples were assayed by LC/MS/MS. We found that blood KS levels (0.4-26 µg/ml) in MPS IVA patients were significantly higher than those in age-matched controls (0.67-4.6 µg/ml; P < 0.0001). It was found that blood KS level varied with age and clinical severity in the patients. Blood KS levels in MPS IVA peaked between 2 years and 5 years of age (mean 11.4 µg/ml). Blood KS levels in severe MPS IVA (mean 7.3 µg/ml) were higher than in the attenuated form (mean 2.1 µg/ml) (P = 0.012). We also found elevated blood KS levels in other types of MPS. These findings indicate that the new KS assay for blood is suitable for early diagnosis and longitudinal assessment of disease severity in MPS IVA.

  13. Quantitation of Cotinine in Nonsmoker Saliva Using Chip Based Nanoelectrospray Tandem Mass Spectrometry

    SciTech Connect

    Tomkins, Bruce A; Van Berkel, Gary J; Jenkins, Roger A; Counts, Richard Wayne

    2006-01-01

    A new analytical procedure was developed for the quantitation of nonsmoker salivary cotinine. Small volumes of saliva were diluted with water, fortified with cotinine-d{sub 3} (internal standard), then passed through small extraction columns. The analyte and internal standard were eluted with 0.1% (v/v) acetic acid/acetonitrile. Aliquots of each extract were analyzed directly, without chromatographic separation, using chip-based (NanoMate{sup TM}) nanospray tandem mass spectrometry. The calculated detection limit was 0.49 ng cotinine/mL saliva. This method was used to quantify salivary cotinine collected from nonsmoking human subjects living in one of three environmental tobacco smoke (ETS) exposure categories or 'cells': 1. smoking home/smoking workplace; 2. smoking home/nonsmoking workplace; and 3. nonsmoking home/smoking workplace. Samples were collected during five sequential days, including Saturday, as part of a larger study to evaluate potential variability in exposure to ETS. Salivary cotinine measurements were made for the purpose of excluding misclassified smokers and for comparison with known levels of exposure to airborne nicotine in each exposure category. The concentrations observed were consistent with those reported from other large studies reported elsewhere. A non-parametric statistical test was applied to the data within each cell. No statistically significant differences were found between the mean cotinine concentrations collected on a weekday as compared to those collected on a weekend day. When the non-parametric test was applied to the three cells, a statistically significant difference was observed between cell 1 compared to cells 2 and 3. The salivary cotinine concentrations were thus statistically invariant over a five-day exposure period, and they were greatest under the conditions of smoking home and smoking workplace.

  14. Determination of Urinary Creatinine in Washington State Residents via Liquid Chromatography/Tandem Mass Spectrometry

    PubMed Central

    West, Caroline E.; Rhodes, Blaine N.

    2014-01-01

    A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS. Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d3 were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d3). The retention time for creatinine was 0.85 minutes. The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L. LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearson r = 0.9898 and R2 = 0.9797, ρ ≤ 0.0001). The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof. PMID:25614740

  15. Reactive extractive electrospray ionization tandem mass spectrometry for sensitive detection of tetrabromobisphenol A derivatives.

    PubMed

    Tian, Yong; Chen, Jian; Ouyang, Yong-zhong; Qu, Guang-bo; Liu, Ai-feng; Wang, Xue-mei; Liu, Chun-xiao; Shi, Jian-bo; Chen, Huan-wen; Jiang, Gui-bin

    2014-03-01

    Sensitive detection of tetrabromobisphenol A (TBBPA) and its derivatives, a group of emerging toxic contaminants, is highly necessitated in environmental investigation. Herein a novel analytical strategy based on reactive extractive electrospray ionization (EESI) tandem mass spectrometry for detection of tetrabromobisphenol A bis(2-hydroxyethyl ether) (TBBPA-BHEE), tetrabromobisphenol A bis(glycidyl ether) (TBBPA-BGE), tetrabromobisphenol A bis(allylether) (TBBPA-BAE), and tetrabromobisphenol S bis(allylether) (TBBPS-BAE) in industrial waste water samples was developed. Active silver cations (Ag(+)), generated by electrospraying a silver nitrate methanol solution (10 mg L(-1)), collides the neutral TBBPA derivatives molecules in the EESI source to form [M+Ag](+) complexes of the analytes under the ambient conditions. Upon collision-induced dissociation (CID), characteristic fragments of the [M+Ag](+) complexes were identified for confident and sensitive detection of the four TBBPA derivatives. Under the optimized experimental conditions, the instrumental limits of detection (LODs) of TBBPA-BHEE, TBBPA-BGE, TBBPA-BAE and TBBPS-BAE were 0.37, 0.050, 0.76, and 4.6 μg L(-1), respectively. The linear ranges extended to 1000 μg L(-1) (R(2)≥0.9919), and the relative standard deviations (RSDs), inter-day variation and intra-day variation were less than 7.8% (n=9), 10.0% (n=5), and 14.8% (n=1 per day for 5 days) for all derivatives. TBBPA derivative manufacturing industrial waste water, river water and tap water samples were fast analyzed with the proposed method. The contents of TBBPA derivatives were various in the collected samples, with the highest 19.9±0.3 μg L(-1) of TBBPA-BAE in the waste water samples. PMID:24528843

  16. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    PubMed

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids. PMID:27530420

  17. Analysis of free amino acids in natural waters by liquid chromatography-tandem mass spectrometry.

    PubMed

    How, Zuo Tong; Busetti, Francesco; Linge, Kathryn L; Kristiana, Ina; Joll, Cynthia A; Charrois, Jeffrey W A

    2014-11-28

    This paper reports a new analytical method for the analysis of 18 amino acids in natural waters using solid-phase extraction (SPE) followed by liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) operated in multiple reaction monitoring mode. Two different preconcentration methods, solid-phase extraction and concentration under reduced pressure, were tested in development of this method. Although concentration under reduced pressure provided better recoveries and method limits of detection for amino acids in ultrapure water, SPE was a more suitable extraction method for real samples due to the lower matrix effects for this method. Even though the strong cation exchange resin used in SPE method introduced exogenous matrix interferences into the sample extracts (inorganic salt originating from the acid-base reaction during the elution step), the SPE method still incorporates a broad sample clean-up and minimised endogenous matrix effects by reducing interferences originating from real water samples. The method limits of quantification (MLQ) for the SPE LC-MS/MS method in ultrapure water ranged from 0.1 to 100 μg L(-1) as N for the different amino acids. The MLQs of the early eluting amino acids were limited by the presence of matrix interfering species, such as inorganic salts in natural water samples. The SPE LC-MS/MS method was successfully applied to the analysis of amino acids in 3 different drinking water source waters: the average total free amino acid content in these waters was found to be 19 μg L(-1) as N, while among the 18 amino acids analysed, the most abundant amino acids were found to be tyrosine, leucine and isoleucine.

  18. [Dynamic behavior of aldicarb and its metabolites in cabbage by liquid chromatography-tandem mass spectrometry].

    PubMed

    Ding, Kuiying; Xu, Wenjuan; Li, Kai; Guo, Liqiang; Sun, Jun

    2016-02-01

    A liquid chromatography-tandem mass spectrometry ( LC-MS/MS ) method was developed for the study of dynamic behavior of aldicarb and its metabolite residues in cabbage. Aldicarb was applied onto cultivated cabbages. The pesticides concentrations were measured periodically (between application and harvest) , and modeled to illustrate the dynamic behavior. The results showed that the liner ranges of aldicarb and its metabolites were from 0. 005 to 0. 2 mg/L, and the recoveries ranged from 78. 9% to 108. 5% with the relative standard deviations of 2. 03%- 8. 91% (n = 8). The aldicarb in cabbage increased at first with the first-order kinetic equation model of c = 0. 020(0.136t) with the correlation coefficient (r2) of 0. 888, and then decreased with the equation of c = 0. 65e(-059t) with the r2 of 0. 979 and the half-life of 29. 1 d. The reducing processes of aldicarb-sulfone and aldicarb-sulfoxide both matched the first-order kinetic equations (c = 23. 4e(-0.044t) and c = 4. 54e(-0.027t) with r2 of 0. 916 and 0. 972 respectively. To meet the limitation requirement of 0. 01 mg/kg, 70. 7, 226. 6 and 176. 3 d were respectively necessary for aldicarb, aldicarb-sulfone and aldicarb-sulfoxide. Final residues of aldicarb-sulfone and aldicarb-sulfoxide were still more than the limitation requirements, indicating that aldicarb should not be used in vegetables of growth cycle shorter than 120 d. This study provided theoretical basis for dynamic behavior of aldicarb residue and its safe use in vegetables. PMID:27382721

  19. Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

    PubMed

    Bussy, Ugo; Li, Ke; Li, Weiming

    2016-05-01

    Analytical methods using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of metabolites or contaminants (or both) in various tissues of aquatic organisms and in the aquatic environment have received increasing attention in the last few years. This review discusses the findings relevant to such procedures published between 2005 and 2015. The aim is to evaluate the advantages, restrictions, and performances of the procedures from sample preparation to mass spectrometry measurement. To support these discussions, a general knowledge on LC-MS/MS is also provided. PMID:26996906

  20. Dataset and standard operating procedure for newborn screening of six lysosomal storage diseases: By tandem mass spectrometry.

    PubMed

    Elliott, Susan; Buroker, Norman; Co