Science.gov

Sample records for accurate 3d surface

  1. Algorithms for Accurate and Fast Plotting of Contour Surfaces in 3D Using Hexahedral Elements

    NASA Astrophysics Data System (ADS)

    Singh, Chandan; Saini, Jaswinder Singh

    2016-07-01

    In the present study, Fast and accurate algorithms for the generation of contour surfaces in 3D are described using hexahedral elements which are popular in finite element analysis. The contour surfaces are described in the form of groups of boundaries of contour segments and their interior points are derived using the contour equation. The locations of contour boundaries and the interior points on contour surfaces are as accurate as the interpolation results obtained by hexahedral elements and thus there are no discrepancies between the analysis and visualization results.

  2. Algorithms for Accurate and Fast Plotting of Contour Surfaces in 3D Using Hexahedral Elements

    NASA Astrophysics Data System (ADS)

    Singh, Chandan; Saini, Jaswinder Singh

    2016-05-01

    In the present study, Fast and accurate algorithms for the generation of contour surfaces in 3D are described using hexahedral elements which are popular in finite element analysis. The contour surfaces are described in the form of groups of boundaries of contour segments and their interior points are derived using the contour equation. The locations of contour boundaries and the interior points on contour surfaces are as accurate as the interpolation results obtained by hexahedral elements and thus there are no discrepancies between the analysis and visualization results.

  3. Accurate, low-cost 3D-models of gullies

    NASA Astrophysics Data System (ADS)

    Onnen, Nils; Gronz, Oliver; Ries, Johannes B.; Brings, Christine

    2015-04-01

    Soil erosion is a widespread problem in arid and semi-arid areas. The most severe form is the gully erosion. They often cut into agricultural farmland and can make a certain area completely unproductive. To understand the development and processes inside and around gullies, we calculated detailed 3D-models of gullies in the Souss Valley in South Morocco. Near Taroudant, we had four study areas with five gullies different in size, volume and activity. By using a Canon HF G30 Camcorder, we made varying series of Full HD videos with 25fps. Afterwards, we used the method Structure from Motion (SfM) to create the models. To generate accurate models maintaining feasible runtimes, it is necessary to select around 1500-1700 images from the video, while the overlap of neighboring images should be at least 80%. In addition, it is very important to avoid selecting photos that are blurry or out of focus. Nearby pixels of a blurry image tend to have similar color values. That is why we used a MATLAB script to compare the derivatives of the images. The higher the sum of the derivative, the sharper an image of similar objects. MATLAB subdivides the video into image intervals. From each interval, the image with the highest sum is selected. E.g.: 20min. video at 25fps equals 30.000 single images. The program now inspects the first 20 images, saves the sharpest and moves on to the next 20 images etc. Using this algorithm, we selected 1500 images for our modeling. With VisualSFM, we calculated features and the matches between all images and produced a point cloud. Then, MeshLab has been used to build a surface out of it using the Poisson surface reconstruction approach. Afterwards we are able to calculate the size and the volume of the gullies. It is also possible to determine soil erosion rates, if we compare the data with old recordings. The final step would be the combination of the terrestrial data with the data from our aerial photography. So far, the method works well and we

  4. Accurate 3D quantification of the bronchial parameters in MDCT

    NASA Astrophysics Data System (ADS)

    Saragaglia, A.; Fetita, C.; Preteux, F.; Brillet, P. Y.; Grenier, P. A.

    2005-08-01

    The assessment of bronchial reactivity and wall remodeling in asthma plays a crucial role in better understanding such a disease and evaluating therapeutic responses. Today, multi-detector computed tomography (MDCT) makes it possible to perform an accurate estimation of bronchial parameters (lumen and wall areas) by allowing a quantitative analysis in a cross-section plane orthogonal to the bronchus axis. This paper provides the tools for such an analysis by developing a 3D investigation method which relies on 3D reconstruction of bronchial lumen and central axis computation. Cross-section images at bronchial locations interactively selected along the central axis are generated at appropriate spatial resolution. An automated approach is then developed for accurately segmenting the inner and outer bronchi contours on the cross-section images. It combines mathematical morphology operators, such as "connection cost", and energy-controlled propagation in order to overcome the difficulties raised by vessel adjacencies and wall irregularities. The segmentation accuracy was validated with respect to a 3D mathematically-modeled phantom of a pair bronchus-vessel which mimics the characteristics of real data in terms of gray-level distribution, caliber and orientation. When applying the developed quantification approach to such a model with calibers ranging from 3 to 10 mm diameter, the lumen area relative errors varied from 3.7% to 0.15%, while the bronchus area was estimated with a relative error less than 5.1%.

  5. Extremely accurate sequential verification of RELAP5-3D

    DOE PAGESBeta

    Mesina, George L.; Aumiller, David L.; Buschman, Francis X.

    2015-11-19

    Large computer programs like RELAP5-3D solve complex systems of governing, closure and special process equations to model the underlying physics of nuclear power plants. Further, these programs incorporate many other features for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. For RELAP5-3D, verification and validation are restricted to nuclear power plant applications. Verification means ensuring that the program is built right by checking that it meets its design specifications, comparing coding to algorithms and equations and comparing calculations against analytical solutions and method ofmore » manufactured solutions. Sequential verification performs these comparisons initially, but thereafter only compares code calculations between consecutive code versions to demonstrate that no unintended changes have been introduced. Recently, an automated, highly accurate sequential verification method has been developed for RELAP5-3D. The method also provides to test that no unintended consequences result from code development in the following code capabilities: repeating a timestep advancement, continuing a run from a restart file, multiple cases in a single code execution, and modes of coupled/uncoupled operation. In conclusion, mathematical analyses of the adequacy of the checks used in the comparisons are provided.« less

  6. Extremely accurate sequential verification of RELAP5-3D

    SciTech Connect

    Mesina, George L.; Aumiller, David L.; Buschman, Francis X.

    2015-11-19

    Large computer programs like RELAP5-3D solve complex systems of governing, closure and special process equations to model the underlying physics of nuclear power plants. Further, these programs incorporate many other features for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. For RELAP5-3D, verification and validation are restricted to nuclear power plant applications. Verification means ensuring that the program is built right by checking that it meets its design specifications, comparing coding to algorithms and equations and comparing calculations against analytical solutions and method of manufactured solutions. Sequential verification performs these comparisons initially, but thereafter only compares code calculations between consecutive code versions to demonstrate that no unintended changes have been introduced. Recently, an automated, highly accurate sequential verification method has been developed for RELAP5-3D. The method also provides to test that no unintended consequences result from code development in the following code capabilities: repeating a timestep advancement, continuing a run from a restart file, multiple cases in a single code execution, and modes of coupled/uncoupled operation. In conclusion, mathematical analyses of the adequacy of the checks used in the comparisons are provided.

  7. AUTOMATED, HIGHLY ACCURATE VERIFICATION OF RELAP5-3D

    SciTech Connect

    George L Mesina; David Aumiller; Francis Buschman

    2014-07-01

    Computer programs that analyze light water reactor safety solve complex systems of governing, closure and special process equations to model the underlying physics. In addition, these programs incorporate many other features and are quite large. RELAP5-3D[1] has over 300,000 lines of coding for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. Verification ensures that a program is built right by checking that it meets its design specifications. Recently, there has been an increased importance on the development of automated verification processes that compare coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions[2]. For the first time, the ability exists to ensure that the data transfer operations associated with timestep advancement/repeating and writing/reading a solution to a file have no unintended consequences. To ensure that the code performs as intended over its extensive list of applications, an automated and highly accurate verification method has been modified and applied to RELAP5-3D. Furthermore, mathematical analysis of the adequacy of the checks used in the comparisons is provided.

  8. Nonlaser-based 3D surface imaging

    SciTech Connect

    Lu, Shin-yee; Johnson, R.K.; Sherwood, R.J.

    1994-11-15

    3D surface imaging refers to methods that generate a 3D surface representation of objects of a scene under viewing. Laser-based 3D surface imaging systems are commonly used in manufacturing, robotics and biomedical research. Although laser-based systems provide satisfactory solutions for most applications, there are situations where non laser-based approaches are preferred. The issues that make alternative methods sometimes more attractive are: (1) real-time data capturing, (2) eye-safety, (3) portability, and (4) work distance. The focus of this presentation is on generating a 3D surface from multiple 2D projected images using CCD cameras, without a laser light source. Two methods are presented: stereo vision and depth-from-focus. Their applications are described.

  9. Methods for comparing 3D surface attributes

    NASA Astrophysics Data System (ADS)

    Pang, Alex; Freeman, Adam

    1996-03-01

    A common task in data analysis is to compare two or more sets of data, statistics, presentations, etc. A predominant method in use is side-by-side visual comparison of images. While straightforward, it burdens the user with the task of discerning the differences between the two images. The user if further taxed when the images are of 3D scenes. This paper presents several methods for analyzing the extent, magnitude, and manner in which surfaces in 3D differ in their attributes. The surface geometry are assumed to be identical and only the surface attributes (color, texture, etc.) are variable. As a case in point, we examine the differences obtained when a 3D scene is rendered progressively using radiosity with different form factor calculation methods. The comparison methods include extensions of simple methods such as mapping difference information to color or transparency, and more recent methods including the use of surface texture, perturbation, and adaptive placements of error glyphs.

  10. 3D-patterned polymer brush surfaces

    NASA Astrophysics Data System (ADS)

    Zhou, Xuechang; Liu, Xuqing; Xie, Zhuang; Zheng, Zijian

    2011-12-01

    Polymer brush-based three-dimensional (3D) structures are emerging as a powerful platform to engineer a surface by providing abundant spatially distributed chemical and physical properties. In this feature article, we aim to give a summary of the recent progress on the fabrication of 3D structures with polymer brushes, with a particular focus on the micro- and nanoscale. We start with a brief introduction on polymer brushes and the challenges to prepare their 3D structures. Then, we highlight the recent advances of the fabrication approaches on the basis of traditional polymerization time and grafting density strategies, and a recently developed feature density strategy. Finally, we provide some perspective outlooks on the future directions of engineering the 3D structures with polymer brushes.

  11. Recognition methods for 3D textured surfaces

    NASA Astrophysics Data System (ADS)

    Cula, Oana G.; Dana, Kristin J.

    2001-06-01

    Texture as a surface representation is the subject of a wide body of computer vision and computer graphics literature. While texture is always associated with a form of repetition in the image, the repeating quantity may vary. The texture may be a color or albedo variation as in a checkerboard, a paisley print or zebra stripes. Very often in real-world scenes, texture is instead due to a surface height variation, e.g. pebbles, gravel, foliage and any rough surface. Such surfaces are referred to here as 3D textured surfaces. Standard texture recognition algorithms are not appropriate for 3D textured surfaces because the appearance of these surfaces changes in a complex manner with viewing direction and illumination direction. Recent methods have been developed for recognition of 3D textured surfaces using a database of surfaces observed under varied imaging parameters. One of these methods is based on 3D textons obtained using K-means clustering of multiscale feature vectors. Another method uses eigen-analysis originally developed for appearance-based object recognition. In this work we develop a hybrid approach that employs both feature grouping and dimensionality reduction. The method is tested using the Columbia-Utrecht texture database and provides excellent recognition rates. The method is compared with existing recognition methods for 3D textured surfaces. A direct comparison is facilitated by empirical recognition rates from the same texture data set. The current method has key advantages over existing methods including requiring less prior information on both the training and novel images.

  12. PLOT3D- DRAWING THREE DIMENSIONAL SURFACES

    NASA Technical Reports Server (NTRS)

    Canright, R. B.

    1994-01-01

    PLOT3D is a package of programs to draw three-dimensional surfaces of the form z = f(x,y). The function f and the boundary values for x and y are the input to PLOT3D. The surface thus defined may be drawn after arbitrary rotations. However, it is designed to draw only functions in rectangular coordinates expressed explicitly in the above form. It cannot, for example, draw a sphere. Output is by off-line incremental plotter or online microfilm recorder. This package, unlike other packages, will plot any function of the form z = f(x,y) and portrays continuous and bounded functions of two independent variables. With curve fitting; however, it can draw experimental data and pictures which cannot be expressed in the above form. The method used is division into a uniform rectangular grid of the given x and y ranges. The values of the supplied function at the grid points (x, y) are calculated and stored; this defines the surface. The surface is portrayed by connecting successive (y,z) points with straight-line segments for each x value on the grid and, in turn, connecting successive (x,z) points for each fixed y value on the grid. These lines are then projected by parallel projection onto the fixed yz-plane for plotting. This program has been implemented on the IBM 360/67 with on-line CDC microfilm recorder.

  13. Surface Plasmons in 3D Topological Insulators

    NASA Astrophysics Data System (ADS)

    Kogar, Anshul; Vig, Sean; Cho, Gil; Thaler, Alexander; Xiao, Yiran; Hughes, Taylor; Wong, Man-Hong; Chiang, Tai-Chang; MacDougall, Greg; Abbamonte, Peter

    2015-03-01

    Most studies of three-dimensional (3D) topological insulators have concentrated on their one-electron properties as exhibited by angle-resolved photoemission spectroscopy (ARPES) or by scanning tunneling microscopy (STM). Many-body interactions are often neglected in the treatment of models of topological insulators, such as in the Kane-Mele and Bernevig-Hughes-Zhang models. Using angle-resolved inelastic electron scattering from the surface, I will present data on the collective mode that owes its existence to the presence of many-body interactions, the surface plasmon (SP), in two known 3D topological insulators, Bi2Se3 and Bi0.5Sb1.5Se1 . 5 + xTe1 . 5 - x. Surprisingly, the SP was prominent even after depressing the Fermi energy into the bulk band gap. Having studied the SP as a function of doping, momentum transfer and its aging properties, I will present evidence to suggest that bulk-surface coupling is crucial in explaining many of its properties. A simple model with dynamic bulk screening will be presented showing qualitative agreement with the observations. Lastly, the relation of the observed surface plasmon to the predicted spin-plasmon mode and to the kinks seen in the electronic dispersion as measured by ARPES will be discussed. The work was supported as part of the Center for Emergent Superconductivity, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science.

  14. PRESAGE 3D dosimetry accurately measures Gamma Knife output factors

    NASA Astrophysics Data System (ADS)

    Klawikowski, Slade J.; Yang, James N.; Adamovics, John; Ibbott, Geoffrey S.

    2014-12-01

    Small-field output factor measurements are traditionally very difficult because of steep dose gradients, loss of lateral electronic equilibrium, and dose volume averaging in finitely sized detectors. Three-dimensional (3D) dosimetry is ideal for measuring small output factors and avoids many of these potential challenges of point and 2D detectors. PRESAGE 3D polymer dosimeters were used to measure the output factors for the 4 mm and 8 mm collimators of the Leksell Perfexion Gamma Knife radiosurgery treatment system. Discrepancies between the planned and measured distance between shot centers were also investigated. A Gamma Knife head frame was mounted onto an anthropomorphic head phantom. Special inserts were machined to hold 60 mm diameter, 70 mm tall cylindrical PRESAGE dosimeters. The phantom was irradiated with one 16 mm shot and either one 4 mm or one 8 mm shot, to a prescribed dose of either 3 Gy or 4 Gy to the 50% isodose line. The two shots were spaced between 30 mm and 60 mm apart and aligned along the central axis of the cylinder. The Presage dosimeters were measured using the DMOS-RPC optical CT scanning system. Five independent 4 mm output factor measurements fell within 2% of the manufacturer’s Monte Carlo simulation-derived nominal value, as did two independent 8 mm output factor measurements. The measured distances between shot centers varied by ±0.8 mm with respect to the planned shot displacements. On the basis of these results, we conclude that PRESAGE dosimetry is excellently suited to quantify the difficult-to-measure Gamma Knife output factors.

  15. 3D surface defect analysis and evaluation

    NASA Astrophysics Data System (ADS)

    Yang, B.; Jia, M.; Song, G. J.; Tao, L.; Harding, K. G.

    2008-08-01

    A method is proposed for surface defect analysis and evaluation. Good 3D point clouds can now be obtained through a variety of surface profiling methods such as stylus tracers, structured light, or interferometry. In order to inspect a surface for defects, first a reference surface that represents the surface without any defects needs to be identified. This reference surface can then be fit to the point cloud. The algorithm we present finds the least square solution for the overdetermined equation set to obtain the parameters of the reference surface mathematical description. The distance between each point within the point cloud and the reference surface is then calculated using to the derived reference surface equation. For analysis of the data, the user can preset a threshold distance value. If the calculated distance is bigger than the threshold value, the corresponding point is marked as a defect point. The software then generates a color-coded map of the measured surface. Defect points that are connected together are formed into a defect-clustering domain. Each defect-clustering domain is treated as one defect area. We then use a clustering domain searching algorithm to auto-search all the defect areas in the point cloud. The different critical parameters used for evaluating the defect status of a point cloud that can be calculated are described as: P-Depth,a peak depth of all defects; Defect Number, the number of surface defects; Defects/Area, the defect number in unit area; and Defect Coverage Ratio which is a ratio of the defect area to the region of interest.

  16. Improving light propagation Monte Carlo simulations with accurate 3D modeling of skin tissue

    SciTech Connect

    Paquit, Vincent C; Price, Jeffery R; Meriaudeau, Fabrice; Tobin Jr, Kenneth William

    2008-01-01

    In this paper, we present a 3D light propagation model to simulate multispectral reflectance images of large skin surface areas. In particular, we aim to simulate more accurately the effects of various physiological properties of the skin in the case of subcutaneous vein imaging compared to existing models. Our method combines a Monte Carlo light propagation model, a realistic three-dimensional model of the skin using parametric surfaces and a vision system for data acquisition. We describe our model in detail, present results from the Monte Carlo modeling and compare our results with those obtained with a well established Monte Carlo model and with real skin reflectance images.

  17. Accurate Automatic Detection of Densely Distributed Cell Nuclei in 3D Space.

    PubMed

    Toyoshima, Yu; Tokunaga, Terumasa; Hirose, Osamu; Kanamori, Manami; Teramoto, Takayuki; Jang, Moon Sun; Kuge, Sayuri; Ishihara, Takeshi; Yoshida, Ryo; Iino, Yuichi

    2016-06-01

    To measure the activity of neurons using whole-brain activity imaging, precise detection of each neuron or its nucleus is required. In the head region of the nematode C. elegans, the neuronal cell bodies are distributed densely in three-dimensional (3D) space. However, no existing computational methods of image analysis can separate them with sufficient accuracy. Here we propose a highly accurate segmentation method based on the curvatures of the iso-intensity surfaces. To obtain accurate positions of nuclei, we also developed a new procedure for least squares fitting with a Gaussian mixture model. Combining these methods enables accurate detection of densely distributed cell nuclei in a 3D space. The proposed method was implemented as a graphical user interface program that allows visualization and correction of the results of automatic detection. Additionally, the proposed method was applied to time-lapse 3D calcium imaging data, and most of the nuclei in the images were successfully tracked and measured. PMID:27271939

  18. Accurate Automatic Detection of Densely Distributed Cell Nuclei in 3D Space

    PubMed Central

    Tokunaga, Terumasa; Kanamori, Manami; Teramoto, Takayuki; Jang, Moon Sun; Kuge, Sayuri; Ishihara, Takeshi; Yoshida, Ryo; Iino, Yuichi

    2016-01-01

    To measure the activity of neurons using whole-brain activity imaging, precise detection of each neuron or its nucleus is required. In the head region of the nematode C. elegans, the neuronal cell bodies are distributed densely in three-dimensional (3D) space. However, no existing computational methods of image analysis can separate them with sufficient accuracy. Here we propose a highly accurate segmentation method based on the curvatures of the iso-intensity surfaces. To obtain accurate positions of nuclei, we also developed a new procedure for least squares fitting with a Gaussian mixture model. Combining these methods enables accurate detection of densely distributed cell nuclei in a 3D space. The proposed method was implemented as a graphical user interface program that allows visualization and correction of the results of automatic detection. Additionally, the proposed method was applied to time-lapse 3D calcium imaging data, and most of the nuclei in the images were successfully tracked and measured. PMID:27271939

  19. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  20. An accurate quadrature technique for the contact boundary in 3D finite element computations

    NASA Astrophysics Data System (ADS)

    Duong, Thang X.; Sauer, Roger A.

    2015-01-01

    This paper presents a new numerical integration technique for 3D contact finite element implementations, focusing on a remedy for the inaccurate integration due to discontinuities at the boundary of contact surfaces. The method is based on the adaptive refinement of the integration domain along the boundary of the contact surface, and is accordingly denoted RBQ for refined boundary quadrature. It can be used for common element types of any order, e.g. Lagrange, NURBS, or T-Spline elements. In terms of both computational speed and accuracy, RBQ exhibits great advantages over a naive increase of the number of quadrature points. Also, the RBQ method is shown to remain accurate for large deformations. Furthermore, since the sharp boundary of the contact surface is determined, it can be used for various purposes like the accurate post-processing of the contact pressure. Several examples are presented to illustrate the new technique.

  1. Development of an accurate 3D blood vessel searching system using NIR light

    NASA Astrophysics Data System (ADS)

    Mizuno, Yoshifumi; Katayama, Tsutao; Nakamachi, Eiji

    2010-02-01

    Health monitoring system (HMS) and drug delivery system (DDS) require accurate puncture by needle for automatic blood sampling. In this study, we develop a miniature and high accurate automatic 3D blood vessel searching system. The size of detecting system is 40x25x10 mm. Our searching system use Near-Infrared (NIR) LEDs, CMOS camera modules and image processing units. We employ the stereo method for searching system to determine 3D blood vessel location. Blood vessel visualization system adopts hemoglobin's absorption characterization of NIR light. NIR LED is set behind the finger and it irradiates Near Infrared light for the finger. CMOS camera modules are set in front of the finger and it captures clear blood vessel images. Two dimensional location of the blood vessel is detected by luminance distribution of the image and its depth is calculated by the stereo method. 3D blood vessel location is automatically detected by our image processing system. To examine the accuracy of our detecting system, we carried out experiments using finger phantoms with blood vessel diameters, 0.5, 0.75, 1.0mm, at the depths, 0.5 ~ 2.0 mm, under the artificial tissue surface. Experimental results of depth obtained by our detecting system showed good agreements with given depths, and the availability of this system is confirmed.

  2. Key techniques for vision measurement of 3D object surface

    NASA Astrophysics Data System (ADS)

    Yang, Huachao; Zhang, Shubi; Guo, Guangli; Liu, Chao; Yu, Ruipeng

    2006-11-01

    Digital close-range photogrammetry system and machine vision are widely used in production control, quality inspection. The main aim is to provide accurate 3D objects or reconstruction of an object surface and give an expression to an object shape. First, the key techniques of camera calibration and target image positioning for 3D object surface vision measurement were briefly reviewed and analyzed in this paper. Then, an innovative and effect method for precise space coordinates measurements was proposed. Test research proved that the thought and methods we proposed about image segmentation, detection and positioning of circular marks were effective and valid. A propriety weight value for adding parameters, control points and orientation elements in bundle adjustment with self-calibration are advantageous to gaining high accuracy of space coordinates. The RMS error of check points is less than +/-1 mm, which can meet the requirement in industrial measurement with high accuracy.

  3. Accurate 3d Scanning of Damaged Ancient Greek Inscriptions for Revealing Weathered Letters

    NASA Astrophysics Data System (ADS)

    Papadaki, A. I.; Agrafiotis, P.; Georgopoulos, A.; Prignitz, S.

    2015-02-01

    In this paper two non-invasive non-destructive alternative techniques to the traditional and invasive technique of squeezes are presented alongside with specialized developed processing methods, aiming to help the epigraphists to reveal and analyse weathered letters in ancient Greek inscriptions carved in masonry or marble. The resulting 3D model would serve as a detailed basis for the epigraphists to try to decipher the inscription. The data were collected by using a Structured Light scanner. The creation of the final accurate three dimensional model is a complicated procedure requiring large computation cost and human effort. It includes the collection of geometric data in limited space and time, the creation of the surface, the noise filtering and the merging of individual surfaces. The use of structured light scanners is time consuming and requires costly hardware and software. Therefore an alternative methodology for collecting 3D data of the inscriptions was also implemented for reasons of comparison. Hence, image sequences from varying distances were collected using a calibrated DSLR camera aiming to reconstruct the 3D scene through SfM techniques in order to evaluate the efficiency and the level of precision and detail of the obtained reconstructed inscriptions. Problems in the acquisition processes as well as difficulties in the alignment step and mesh optimization are also encountered. A meta-processing framework is proposed and analysed. Finally, the results of processing and analysis and the different 3D models are critically inspected and then evaluated by a specialist in terms of accuracy, quality and detail of the model and the capability of revealing damaged and "hidden" letters.

  4. The fast and accurate 3D-face scanning technology based on laser triangle sensors

    NASA Astrophysics Data System (ADS)

    Wang, Jinjiang; Chang, Tianyu; Ge, Baozhen; Tian, Qingguo; Chen, Yang; Kong, Bin

    2013-08-01

    A laser triangle scanning method and the structure of 3D-face measurement system were introduced. In presented system, a liner laser source was selected as an optical indicated signal in order to scanning a line one times. The CCD image sensor was used to capture image of the laser line modulated by human face. The system parameters were obtained by system calibrated calculated. The lens parameters of image part of were calibrated with machine visual image method and the triangle structure parameters were calibrated with fine wire paralleled arranged. The CCD image part and line laser indicator were set with a linear motor carry which can achieve the line laser scanning form top of the head to neck. For the nose is ledge part and the eyes are sunk part, one CCD image sensor can not obtain the completed image of laser line. In this system, two CCD image sensors were set symmetric at two sides of the laser indicator. In fact, this structure includes two laser triangle measure units. Another novel design is there laser indicators were arranged in order to reduce the scanning time for it is difficult for human to keep static for longer time. The 3D data were calculated after scanning. And further data processing include 3D coordinate refine, mesh calculate and surface show. Experiments show that this system has simply structure, high scanning speed and accurate. The scanning range covers the whole head of adult, the typical resolution is 0.5mm.

  5. Method for accurate sizing of pulmonary vessels from 3D medical images

    NASA Astrophysics Data System (ADS)

    O'Dell, Walter G.

    2015-03-01

    Detailed characterization of vascular anatomy, in particular the quantification of changes in the distribution of vessel sizes and of vascular pruning, is essential for the diagnosis and management of a variety of pulmonary vascular diseases and for the care of cancer survivors who have received radiation to the thorax. Clinical estimates of vessel radii are typically based on setting a pixel intensity threshold and counting how many "On" pixels are present across the vessel cross-section. A more objective approach introduced recently involves fitting the image with a library of spherical Gaussian filters and utilizing the size of the best matching filter as the estimate of vessel diameter. However, both these approaches have significant accuracy limitations including mis-match between a Gaussian intensity distribution and that of real vessels. Here we introduce and demonstrate a novel approach for accurate vessel sizing using 3D appearance models of a tubular structure along a curvilinear trajectory in 3D space. The vessel branch trajectories are represented with cubic Hermite splines and the tubular branch surfaces represented as a finite element surface mesh. An iterative parameter adjustment scheme is employed to optimally match the appearance models to a patient's chest X-ray computed tomography (CT) scan to generate estimates for branch radii and trajectories with subpixel resolution. The method is demonstrated on pulmonary vasculature in an adult human CT scan, and on 2D simulated test cases.

  6. Multi Sensor Data Integration for AN Accurate 3d Model Generation

    NASA Astrophysics Data System (ADS)

    Chhatkuli, S.; Satoh, T.; Tachibana, K.

    2015-05-01

    The aim of this paper is to introduce a novel technique of data integration between two different data sets, i.e. laser scanned RGB point cloud and oblique imageries derived 3D model, to create a 3D model with more details and better accuracy. In general, aerial imageries are used to create a 3D city model. Aerial imageries produce an overall decent 3D city models and generally suit to generate 3D model of building roof and some non-complex terrain. However, the automatically generated 3D model, from aerial imageries, generally suffers from the lack of accuracy in deriving the 3D model of road under the bridges, details under tree canopy, isolated trees, etc. Moreover, the automatically generated 3D model from aerial imageries also suffers from undulated road surfaces, non-conforming building shapes, loss of minute details like street furniture, etc. in many cases. On the other hand, laser scanned data and images taken from mobile vehicle platform can produce more detailed 3D road model, street furniture model, 3D model of details under bridge, etc. However, laser scanned data and images from mobile vehicle are not suitable to acquire detailed 3D model of tall buildings, roof tops, and so forth. Our proposed approach to integrate multi sensor data compensated each other's weakness and helped to create a very detailed 3D model with better accuracy. Moreover, the additional details like isolated trees, street furniture, etc. which were missing in the original 3D model derived from aerial imageries could also be integrated in the final model automatically. During the process, the noise in the laser scanned data for example people, vehicles etc. on the road were also automatically removed. Hence, even though the two dataset were acquired in different time period the integrated data set or the final 3D model was generally noise free and without unnecessary details.

  7. 3D Surface Reconstruction and Automatic Camera Calibration

    NASA Technical Reports Server (NTRS)

    Jalobeanu, Andre

    2004-01-01

    Illustrations in this view-graph presentation are presented on a Bayesian approach to 3D surface reconstruction and camera calibration.Existing methods, surface analysis and modeling,preliminary surface reconstruction results, and potential applications are addressed.

  8. Accurate compressed look up table method for CGH in 3D holographic display.

    PubMed

    Gao, Chuan; Liu, Juan; Li, Xin; Xue, Gaolei; Jia, Jia; Wang, Yongtian

    2015-12-28

    Computer generated hologram (CGH) should be obtained with high accuracy and high speed in 3D holographic display, and most researches focus on the high speed. In this paper, a simple and effective computation method for CGH is proposed based on Fresnel diffraction theory and look up table. Numerical simulations and optical experiments are performed to demonstrate its feasibility. The proposed method can obtain more accurate reconstructed images with lower memory usage compared with split look up table method and compressed look up table method without sacrificing the computational speed in holograms generation, so it is called accurate compressed look up table method (AC-LUT). It is believed that AC-LUT method is an effective method to calculate the CGH of 3D objects for real-time 3D holographic display where the huge information data is required, and it could provide fast and accurate digital transmission in various dynamic optical fields in the future. PMID:26831987

  9. S3D: An interactive surface grid generation tool

    NASA Technical Reports Server (NTRS)

    Luh, Raymond Ching-Chung; Pierce, Lawrence E.; Yip, David

    1992-01-01

    S3D, an interactive software tool for surface grid generation, is described. S3D provides the means with which a geometry definition based either on a discretized curve set or a rectangular set can be quickly processed towards the generation of a surface grid for computational fluid dynamics (CFD) applications. This is made possible as a result of implementing commonly encountered surface gridding tasks in an environment with a highly efficient and user friendly graphical interface. Some of the more advanced features of S3D include surface-surface intersections, optimized surface domain decomposition and recomposition, and automated propagation of edge distributions to surrounding grids.

  10. Enabling accurate gate profile control with inline 3D-AFM

    NASA Astrophysics Data System (ADS)

    Bao, Tianming; Lopez, Andrew; Dawson, Dean

    2009-05-01

    The logic and memory semiconductor device technology strives to follow the aggressive ITRS roadmap. The ITRS calls for increased 3D metrology to meet the demand for tighter process control at 45nm and 32nm nodes. In particular, gate engineering has advanced to a level where conventional metrology by CD-SEM and optical scatterometry (OCD) faces fundamental limitations without involvement of 3D atomic force microscope (3D-AFM or CD-AFM). This paper reports recent progress in 3D-AFM to address the metrology need to control gate dimension in MOSFET transistor formation. 3D-AFM metrology measures the gate electrode at post-etch with the lowest measurement uncertainty for critical gate geometry, including linewidth, sidewall profile, sidewall angle (SWA), line width roughness (LWR), and line edge roughness (LER). 3D-AFM enables accurate gate profile control in three types of metrology applications: reference metrology to validate CD-SEM and OCD, inline depth or 3D monitoring, or replacing TEM for 3D characterization for engineering analysis.

  11. An accurate 3D inspection system using heterodyne multiple frequency phase-shifting algorithm

    NASA Astrophysics Data System (ADS)

    Xiao, Zhenzhong; Chee, Oichoo; Asundi, Anand

    This paper presents an accurate 3D inspection system for industrial applications, which uses digital fringe projection technology. The system consists of two CCD cameras and a DLP projector. The mathematical model of the 3D inspection system with 10 distortion parameters for each camera is proposed. A heterodyne multiple frequency phase-shifting algorithm is employed for overcoming the unwrapping problem of phase functions and for a reliable unwrapping procedure. The redundant phase information is used to increase the accuracy of the 3D reconstruction. To demonstrate the effectiveness of our system, a standard sphere was used for testing. The verification test for the 3D inspection systems are based on the VDI standard 2634. The result shows the proposed system can be used for industrial quality inspection with high measurement precision.

  12. Building an accurate 3D model of a circular feature for robot vision

    NASA Astrophysics Data System (ADS)

    Li, L.

    2012-06-01

    In this paper, an accurate 3D model analysis of a circular feature is built with error compensation for robot vision. We propose an efficient method of fitting ellipses to data points by minimizing the algebraic distance subject to the constraint that a conic should be an ellipse and solving the ellipse parameters through a direct ellipse fitting method by analysing the 3D geometrical representation in a perspective projection scheme, the 3D position of a circular feature with known radius can be obtained. A set of identical circles, machined on a calibration board whose centres were known, was calibrated with a camera and did the model analysis that our method developed. Experimental results show that our method is more accurate than other methods.

  13. Target surface finding using 3D SAR data

    NASA Astrophysics Data System (ADS)

    Ruiter, Jason R.; Burns, Joseph W.; Subotic, Nikola S.

    2005-05-01

    Methods of generating more literal, easily interpretable imagery from 3-D SAR data are being studied to provide all weather, near-visual target identification and/or scene interpretation. One method of approaching this problem is to automatically generate shape-based geometric renderings from the SAR data. In this paper we describe the application of the Marching Tetrahedrons surface finding algorithm to 3-D SAR data. The Marching Tetrahedrons algorithm finds a surface through the 3-D data cube, which provides a recognizable representation of the target surface. This algorithm was applied to the public-release X-patch simulations of a backhoe, which provided densely sampled 3-D SAR data sets. The performance of the algorithm to noise and spatial resolution were explored. Surface renderings were readily recognizable over a range of spatial resolution, and maintained their fidelity even under relatively low Signal-to-Noise Ratio (SNR) conditions.

  14. Accurate 3D reconstruction of complex blood vessel geometries from intravascular ultrasound images: in vitro study.

    PubMed

    Subramanian, K R; Thubrikar, M J; Fowler, B; Mostafavi, M T; Funk, M W

    2000-01-01

    We present a technique that accurately reconstructs complex three dimensional blood vessel geometry from 2D intravascular ultrasound (IVUS) images. Biplane x-ray fluoroscopy is used to image the ultrasound catheter tip at a few key points along its path as the catheter is pulled through the blood vessel. An interpolating spline describes the continuous catheter path. The IVUS images are located orthogonal to the path, resulting in a non-uniform structured scalar volume of echo densities. Isocontour surfaces are used to view the vessel geometry, while transparency and clipping enable interactive exploration of interior structures. The two geometries studied are a bovine artery vascular graft having U-shape and a constriction, and a canine carotid artery having multiple branches and a constriction. Accuracy of the reconstructions is established by comparing the reconstructions to (1) silicone moulds of the vessel interior, (2) biplane x-ray images, and (3) the original echo images. Excellent shape and geometry correspondence was observed in both geometries. Quantitative measurements made at key locations of the 3D reconstructions also were in good agreement with those made in silicone moulds. The proposed technique is easily adoptable in clinical practice, since it uses x-rays with minimal exposure and existing IVUS technology. PMID:11105284

  15. Accurate 3d Textured Models of Vessels for the Improvement of the Educational Tools of a Museum

    NASA Astrophysics Data System (ADS)

    Soile, S.; Adam, K.; Ioannidis, C.; Georgopoulos, A.

    2013-02-01

    Besides the demonstration of the findings, modern museums organize educational programs which aim to experience and knowledge sharing combined with entertainment rather than to pure learning. Toward that effort, 2D and 3D digital representations are gradually replacing the traditional recording of the findings through photos or drawings. The present paper refers to a project that aims to create 3D textured models of two lekythoi that are exhibited in the National Archaeological Museum of Athens in Greece; on the surfaces of these lekythoi scenes of the adventures of Odysseus are depicted. The project is expected to support the production of an educational movie and some other relevant interactive educational programs for the museum. The creation of accurate developments of the paintings and of accurate 3D models is the basis for the visualization of the adventures of the mythical hero. The data collection was made by using a structured light scanner consisting of two machine vision cameras that are used for the determination of geometry of the object, a high resolution camera for the recording of the texture, and a DLP projector. The creation of the final accurate 3D textured model is a complicated and tiring procedure which includes the collection of geometric data, the creation of the surface, the noise filtering, the merging of individual surfaces, the creation of a c-mesh, the creation of the UV map, the provision of the texture and, finally, the general processing of the 3D textured object. For a better result a combination of commercial and in-house software made for the automation of various steps of the procedure was used. The results derived from the above procedure were especially satisfactory in terms of accuracy and quality of the model. However, the procedure was proved to be time consuming while the use of various software packages presumes the services of a specialist.

  16. 3D surface analysis and classification in neuroimaging segmentation.

    PubMed

    Zagar, Martin; Mlinarić, Hrvoje; Knezović, Josip

    2011-06-01

    This work emphasizes new algorithms for 3D edge and corner detection used in surface extraction and new concept of image segmentation in neuroimaging based on multidimensional shape analysis and classification. We propose using of NifTI standard for describing input data which enables interoperability and enhancement of existing computing tools used widely in neuroimaging research. In methods section we present our newly developed algorithm for 3D edge and corner detection, together with the algorithm for estimating local 3D shape. Surface of estimated shape is analyzed and segmented according to kernel shapes. PMID:21755723

  17. A Cavity Corrected 3D-RISM Functional for Accurate Solvation Free Energies

    PubMed Central

    2014-01-01

    We show that an Ng bridge function modified version of the three-dimensional reference interaction site model (3D-RISM-NgB) solvation free energy method can accurately predict the hydration free energy (HFE) of a set of 504 organic molecules. To achieve this, a single unique constant parameter was adjusted to the computed HFE of single atom Lennard-Jones solutes. It is shown that 3D-RISM is relatively accurate at predicting the electrostatic component of the HFE without correction but requires a modification of the nonpolar contribution that originates in the formation of the cavity created by the solute in water. We use a free energy functional with the Ng scaling of the direct correlation function [Ng, K. C. J. Chem. Phys.1974, 61, 2680]. This produces a rapid, reliable small molecule HFE calculation for applications in drug design. PMID:24634616

  18. A Cavity Corrected 3D-RISM Functional for Accurate Solvation Free Energies.

    PubMed

    Truchon, Jean-François; Pettitt, B Montgomery; Labute, Paul

    2014-03-11

    We show that an Ng bridge function modified version of the three-dimensional reference interaction site model (3D-RISM-NgB) solvation free energy method can accurately predict the hydration free energy (HFE) of a set of 504 organic molecules. To achieve this, a single unique constant parameter was adjusted to the computed HFE of single atom Lennard-Jones solutes. It is shown that 3D-RISM is relatively accurate at predicting the electrostatic component of the HFE without correction but requires a modification of the nonpolar contribution that originates in the formation of the cavity created by the solute in water. We use a free energy functional with the Ng scaling of the direct correlation function [Ng, K. C. J. Chem. Phys. 1974, 61, 2680]. This produces a rapid, reliable small molecule HFE calculation for applications in drug design. PMID:24634616

  19. 3D face recognition based on matching of facial surfaces

    NASA Astrophysics Data System (ADS)

    Echeagaray-Patrón, Beatriz A.; Kober, Vitaly

    2015-09-01

    Face recognition is an important task in pattern recognition and computer vision. In this work a method for 3D face recognition in the presence of facial expression and poses variations is proposed. The method uses 3D shape data without color or texture information. A new matching algorithm based on conformal mapping of original facial surfaces onto a Riemannian manifold followed by comparison of conformal and isometric invariants computed in the manifold is suggested. Experimental results are presented using common 3D face databases that contain significant amount of expression and pose variations.

  20. Diffusion Monte Carlo for Accurate Dissociation Energies of 3d Transition Metal Containing Molecules.

    PubMed

    Doblhoff-Dier, Katharina; Meyer, Jörg; Hoggan, Philip E; Kroes, Geert-Jan; Wagner, Lucas K

    2016-06-14

    Transition metals and transition metal compounds are important to catalysis, photochemistry, and many superconducting systems. We study the performance of diffusion Monte Carlo (DMC) applied to transition metal containing dimers (TMCDs) using single-determinant Slater-Jastrow trial wavefunctions and investigate the possible influence of the locality and pseudopotential errors. We find that the locality approximation can introduce nonsystematic errors of up to several tens of kilocalories per mole in the absolute energy of Cu and CuH if Ar or Mg core pseudopotentials (PPs) are used for the 3d transition metal atoms. Even for energy differences such as binding energies, errors due to the locality approximation can be problematic if chemical accuracy is sought. The use of the Ne core PPs developed by Burkatzki et al. (J. Chem. Phys. 2008, 129, 164115), the use of linear energy minimization rather than unreweighted variance minimization for the optimization of the Jastrow function, and the use of large Jastrow parametrizations reduce the locality errors. In the second section of this article, we study the general performance of DMC for 3d TMCDs using a database of binding energies of 20 TMCDs, for which comparatively accurate experimental data is available. Comparing our DMC results to these data for our results that compare best with experiment, we find a mean unsigned error (MUE) of 4.5 kcal/mol. This compares well with the achievable accuracy in CCSDT(2)Q (MUE = 4.6 kcal/mol) and the best all-electron DFT results (MUE = 4.5 kcal/mol) for the same set of systems (Truhlar et al. J. Chem. Theory Comput. 2015, 11, 2036-2052). The mean errors in DMC depend less on the exchange-correlation functionals used to generate the trial wavefunction than the corresponding mean errors in the underlying DFT calculations. Furthermore, the QMC results obtained for each molecule individually vary less with the functionals used. These observations are relevant for systems such as

  1. Transaction rules for updating surfaces in 3D GIS

    NASA Astrophysics Data System (ADS)

    Gröger, Gerhard; Plümer, Lutz

    2012-04-01

    Three-dimensional surface models representing the terrain and the outer hull of objects such as buildings and bridges support important 3D GIS applications, for example telecommunication planning and noise emission simulation. Updates of surface models often introduce errors which violate basic assumptions of users and their applications. The notion of geometric-topological consistency covers many of these assumptions. It guarantees that objects do not penetrate mutually or that objects completely cover other objects. Assuring that updates do not violate geometric-topological consistency constitutes a major challenge for 3D GIS which has not been satisfactorily met so far. This article presents a solution which is based on efficient transaction rules for updating 3D surface models. We show that these rules are safe (consistency is preserved by any rule application) and complete (any consistent surface model can be generated by successive rule applications). For both properties rigorous mathematic proofs are given.

  2. 3D Human cartilage surface characterization by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Brill, Nicolai; Riedel, Jörn; Schmitt, Robert; Tingart, Markus; Truhn, Daniel; Pufe, Thomas; Jahr, Holger; Nebelung, Sven

    2015-10-01

    Early diagnosis and treatment of cartilage degeneration is of high clinical interest. Loss of surface integrity is considered one of the earliest and most reliable signs of degeneration, but cannot currently be evaluated objectively. Optical Coherence Tomography (OCT) is an arthroscopically available light-based non-destructive real-time imaging technology that allows imaging at micrometre resolutions to millimetre depths. As OCT-based surface evaluation standards remain to be defined, the present study investigated the diagnostic potential of 3D surface profile parameters in the comprehensive evaluation of cartilage degeneration. To this end, 45 cartilage samples of different degenerative grades were obtained from total knee replacements (2 males, 10 females; mean age 63.8 years), cut to standard size and imaged using a spectral-domain OCT device (Thorlabs, Germany). 3D OCT datasets of 8  ×  8, 4  ×  4 and 1  ×  1 mm (width  ×  length) were obtained and pre-processed (image adjustments, morphological filtering). Subsequent automated surface identification algorithms were used to obtain the 3D primary profiles, which were then filtered and processed using established algorithms employing ISO standards. The 3D surface profile thus obtained was used to calculate a set of 21 3D surface profile parameters, i.e. height (e.g. Sa), functional (e.g. Sk), hybrid (e.g. Sdq) and segmentation-related parameters (e.g. Spd). Samples underwent reference histological assessment according to the Degenerative Joint Disease classification. Statistical analyses included calculation of Spearman’s rho and assessment of inter-group differences using the Kruskal Wallis test. Overall, the majority of 3D surface profile parameters revealed significant degeneration-dependent differences and correlations with the exception of severe end-stage degeneration and were of distinct diagnostic value in the assessment of surface integrity. None of the 3D

  3. 3D Human cartilage surface characterization by optical coherence tomography.

    PubMed

    Brill, Nicolai; Riedel, Jörn; Schmitt, Robert; Tingart, Markus; Truhn, Daniel; Pufe, Thomas; Jahr, Holger; Nebelung, Sven

    2015-10-01

    Early diagnosis and treatment of cartilage degeneration is of high clinical interest. Loss of surface integrity is considered one of the earliest and most reliable signs of degeneration, but cannot currently be evaluated objectively. Optical Coherence Tomography (OCT) is an arthroscopically available light-based non-destructive real-time imaging technology that allows imaging at micrometre resolutions to millimetre depths. As OCT-based surface evaluation standards remain to be defined, the present study investigated the diagnostic potential of 3D surface profile parameters in the comprehensive evaluation of cartilage degeneration. To this end, 45 cartilage samples of different degenerative grades were obtained from total knee replacements (2 males, 10 females; mean age 63.8 years), cut to standard size and imaged using a spectral-domain OCT device (Thorlabs, Germany). 3D OCT datasets of 8  ×  8, 4  ×  4 and 1  ×  1 mm (width  ×  length) were obtained and pre-processed (image adjustments, morphological filtering). Subsequent automated surface identification algorithms were used to obtain the 3D primary profiles, which were then filtered and processed using established algorithms employing ISO standards. The 3D surface profile thus obtained was used to calculate a set of 21 3D surface profile parameters, i.e. height (e.g. Sa), functional (e.g. Sk), hybrid (e.g. Sdq) and segmentation-related parameters (e.g. Spd). Samples underwent reference histological assessment according to the Degenerative Joint Disease classification. Statistical analyses included calculation of Spearman's rho and assessment of inter-group differences using the Kruskal Wallis test. Overall, the majority of 3D surface profile parameters revealed significant degeneration-dependent differences and correlations with the exception of severe end-stage degeneration and were of distinct diagnostic value in the assessment of surface integrity. None of the 3D surface

  4. Studies of the 3D surface roughness height

    SciTech Connect

    Avisane, Anita; Rudzitis, Janis; Kumermanis, Maris

    2013-12-16

    Nowadays nano-coatings occupy more and more significant place in technology. Innovative, functional coatings acquire new aspects from the point of view of modern technologies, considering the aggregate of physical properties that can be achieved manipulating in the production process with the properties of coatings’ surfaces on micro- and nano-level. Nano-coatings are applied on machine parts, friction surfaces, contacting parts, corrosion surfaces, transparent conducting films (TCF), etc. The equipment available at present for the production of transparent conducting oxide (TCO) coatings with highest quality is based on expensive indium tin oxide (ITO) material; therefore cheaper alternatives are being searched for. One such offered alternative is zink oxide (ZnO) nano-coatings. Evaluating the TCF physical and mechanical properties and in view of the new ISO standard (EN ISO 25178) on the introduction of surface texture (3D surface roughness) in the engineering calculations, it is necessary to examine the height of 3D surface roughness, which is one of the most significant roughness parameters. The given paper studies the average values of 3D surface roughness height and the most often applied distribution laws are as follows: the normal distribution and Rayleigh distribution. The 3D surface is simulated by a normal random field.

  5. Studies of the 3D surface roughness height

    NASA Astrophysics Data System (ADS)

    Avisane, Anita; Rudzitis, Janis; Kumermanis, Maris

    2013-12-01

    Nowadays nano-coatings occupy more and more significant place in technology. Innovative, functional coatings acquire new aspects from the point of view of modern technologies, considering the aggregate of physical properties that can be achieved manipulating in the production process with the properties of coatings' surfaces on micro- and nano-level. Nano-coatings are applied on machine parts, friction surfaces, contacting parts, corrosion surfaces, transparent conducting films (TCF), etc. The equipment available at present for the production of transparent conducting oxide (TCO) coatings with highest quality is based on expensive indium tin oxide (ITO) material; therefore cheaper alternatives are being searched for. One such offered alternative is zink oxide (ZnO) nano-coatings. Evaluating the TCF physical and mechanical properties and in view of the new ISO standard (EN ISO 25178) on the introduction of surface texture (3D surface roughness) in the engineering calculations, it is necessary to examine the height of 3D surface roughness, which is one of the most significant roughness parameters. The given paper studies the average values of 3D surface roughness height and the most often applied distribution laws are as follows: the normal distribution and Rayleigh distribution. The 3D surface is simulated by a normal random field.

  6. A fast and accurate method to predict 2D and 3D aerodynamic boundary layer flows

    NASA Astrophysics Data System (ADS)

    Bijleveld, H. A.; Veldman, A. E. P.

    2014-12-01

    A quasi-simultaneous interaction method is applied to predict 2D and 3D aerodynamic flows. This method is suitable for offshore wind turbine design software as it is a very accurate and computationally reasonably cheap method. This study shows the results for a NACA 0012 airfoil. The two applied solvers converge to the experimental values when the grid is refined. We also show that in separation the eigenvalues remain positive thus avoiding the Goldstein singularity at separation. In 3D we show a flow over a dent in which separation occurs. A rotating flat plat is used to show the applicability of the method for rotating flows. The shown capabilities of the method indicate that the quasi-simultaneous interaction method is suitable for design methods for offshore wind turbine blades.

  7. 3D surface digitizing and modeling development at ITRI

    NASA Astrophysics Data System (ADS)

    Hsueh, Wen-Jean

    2000-06-01

    This paper gives an overview of the research and development activities in 3D surface digitizing and modeling conducted at the Industrial Technology Research Institute (ITRI) of Taiwan in the past decade. As a major technology and consulting service provider of the area, ITRI has developed 3D laser scanning digitizers ranging from low-cost compacts, industrial CAD/CAM digitizing, to large human body scanner, with in-house 3D surface modeling software to provide total solution in reverse engineering that requires processing capabilities of large number of 3D data. Based on both hardware and software technologies in scanning, merging, registration, surface fitting, reconstruction, and compression, ITRI is now exploring innovative methodologies that provide higher performances, including hardware-based correlation algorithms with advanced camera designs, animation surface model reconstruction, and optical tracking for motion capture. It is expected that the need for easy and fast high-quality 3D information in the near future will grow exponentially, at the same amazing rate as the internet and the human desire for realistic and natural images.

  8. Portable and accurate 3D scanner for breast implant design and reconstructive plastic surgery

    NASA Astrophysics Data System (ADS)

    Rigotti, Camilla; Borghese, Nunzio A.; Ferrari, Stefano; Baroni, Guido; Ferrigno, Giancarlo

    1998-06-01

    In order to evaluate the proper breast implant, the surgeon relies on a standard set of measurements manually taken on the subject. This approach does not allow to obtain an accurate reconstruction of the breast shape and asymmetries can easily arise after surgery. The purpose of this work is to present a method which can help the surgeon in the choice of the shape and dimensions of a prosthesis allowing for a perfect symmetry between the prosthesis and the controlateral breast and can be used as a 3D visual feedback in plastic surgery.

  9. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

    SciTech Connect

    Bache, Steven T.; Juang, Titania; Belley, Matthew D.; Koontz, Bridget F.; Yoshizumi, Terry T.; Kirsch, David G.; Oldham, Mark; Adamovics, John

    2015-02-15

    continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical-CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent-morphic dosimeters that had been sectioned in half. Results: Rodent-morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical-CT dose readout in high-resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone-beam CT image guidance was possible with these dosimeters due to sufficient contrast between high-Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical-CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%. Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent-morphic dosimeters incorporating spinal-mimicking inserts. High quality optical-CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.

  10. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters

    PubMed Central

    Bache, Steven T.; Juang, Titania; Belley, Matthew D.; Koontz, Bridget F.; Adamovics, John; Yoshizumi, Terry T.; Kirsch, David G.; Oldham, Mark

    2015-01-01

    continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical-CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent-morphic dosimeters that had been sectioned in half. Results: Rodent-morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical-CT dose readout in high-resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone-beam CT image guidance was possible with these dosimeters due to sufficient contrast between high-Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical-CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%. Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent-morphic dosimeters incorporating spinal-mimicking inserts. High quality optical-CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT. PMID:25652497

  11. A 3D surface imaging system for assessing human obesity

    NASA Astrophysics Data System (ADS)

    Xu, B.; Yu, W.; Yao, M.; Yao, X.; Li, Q.; Pepper, M. R.; Freeland-Graves, J. H.

    2009-08-01

    The increasing prevalence of obesity suggests a need to develop a convenient, reliable and economical tool for assessment of this condition. Three-dimensional (3D) body surface imaging has emerged as an exciting technology for estimation of body composition. This paper presents a new 3D body imaging system, which was designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology was used to satisfy the requirements for a simple hardware setup and fast image acquisitions. The portability of the system was created via a two-stand configuration, and the accuracy of body volume measurements was improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3D body imaging. Body measurement functions dedicated to body composition assessment also were developed. The overall performance of the system was evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.

  12. Overview of 3D surface digitization technologies in Europe

    NASA Astrophysics Data System (ADS)

    D'Apuzzo, Nicola

    2006-02-01

    This paper presents an overview of the different 3D surface digitization technologies commercially available in the European market. The solutions for 3D surface measurement offered by major European companies can be divided into different groups depending on various characteristics, such as technology (e.g. laser scanning, white light projection), system construction (e.g. fix, on CMM/robot/arm) or measurement type (e.g. surface scanning, profile scanning). Crossing between the categories is possible, however, the majority of commercial products can be divided into the following groups: (a) laser profilers mounted on CMM, (b) portable coded light projection systems, (c) desktop solutions with laser profiler or coded light projectin system and multi-axes platform, (d) laser point measurement systems where both sensor and object move, (e) hand operated laser profilers, hand held laser profiler or point measurement systems, (f) dedicated systems. This paper presents the different 3D surface digitization technologies and describes them with their advantages and disadvantages. Various examples of their use are shown for different application fields. A special interest is given to applications regarding the 3D surface measurement of the human body.

  13. 3DSEM++: Adaptive and intelligent 3D SEM surface reconstruction.

    PubMed

    Tafti, Ahmad P; Holz, Jessica D; Baghaie, Ahmadreza; Owen, Heather A; He, Max M; Yu, Zeyun

    2016-08-01

    Structural analysis of microscopic objects is a longstanding topic in several scientific disciplines, such as biological, mechanical, and materials sciences. The scanning electron microscope (SEM), as a promising imaging equipment has been around for decades to determine the surface properties (e.g., compositions or geometries) of specimens by achieving increased magnification, contrast, and resolution greater than one nanometer. Whereas SEM micrographs still remain two-dimensional (2D), many research and educational questions truly require knowledge and facts about their three-dimensional (3D) structures. 3D surface reconstruction from SEM images leads to remarkable understanding of microscopic surfaces, allowing informative and qualitative visualization of the samples being investigated. In this contribution, we integrate several computational technologies including machine learning, contrario methodology, and epipolar geometry to design and develop a novel and efficient method called 3DSEM++ for multi-view 3D SEM surface reconstruction in an adaptive and intelligent fashion. The experiments which have been performed on real and synthetic data assert the approach is able to reach a significant precision to both SEM extrinsic calibration and its 3D surface modeling. PMID:27200484

  14. Accurately measuring volume of soil samples using low cost Kinect 3D scanner

    NASA Astrophysics Data System (ADS)

    van der Sterre, Boy-Santhos; Hut, Rolf; van de Giesen, Nick

    2013-04-01

    The 3D scanner of the Kinect game controller can be used to increase the accuracy and efficiency of determining in situ soil moisture content. Soil moisture is one of the principal hydrological variables in both the water and energy interactions between soil and atmosphere. Current in situ measurements of soil moisture either rely on indirect measurements (of electromagnetic constants or heat capacity) or on physically taking a sample and weighing it in a lab. The bottleneck in accurately retrieving soil moisture using samples is the determining of the volume of the sample. Currently this is mostly done by the very time consuming "sand cone method" in which the volume were the sample used to sit is filled with sand. We show that 3D scanner that is part of the 150 game controller extension "Kinect" can be used to make 3D scans before and after taking the sample. The accuracy of this method is tested by scanning forms of known volume. This method is less time consuming and less error-prone than using a sand cone.

  15. Accurately measuring volume of soil samples using low cost Kinect 3D scanner

    NASA Astrophysics Data System (ADS)

    van der Sterre, B.; Hut, R.; Van De Giesen, N.

    2012-12-01

    The 3D scanner of the Kinect game controller can be used to increase the accuracy and efficiency of determining in situ soil moisture content. Soil moisture is one of the principal hydrological variables in both the water and energy interactions between soil and atmosphere. Current in situ measurements of soil moisture either rely on indirect measurements (of electromagnetic constants or heat capacity) or on physically taking a sample and weighing it in a lab. The bottleneck in accurately retrieving soil moisture using samples is the determining of the volume of the sample. Currently this is mostly done by the very time consuming "sand cone method" in which the volume were the sample used to sit is filled with sand. We show that 3D scanner that is part of the $150 game controller extension "Kinect" can be used to make 3D scans before and after taking the sample. The accuracy of this method is tested by scanning forms of known volume. This method is less time consuming and less error-prone than using a sand cone.

  16. WaveQ3D: Fast and accurate acoustic transmission loss (TL) eigenrays, in littoral environments

    NASA Astrophysics Data System (ADS)

    Reilly, Sean M.

    This study defines a new 3D Gaussian ray bundling acoustic transmission loss model in geodetic coordinates: latitude, longitude, and altitude. This approach is designed to lower the computation burden of computing accurate environmental effects in sonar training application by eliminating the need to transform the ocean environment into a collection of Nx2D Cartesian radials. This approach also improves model accuracy by incorporating real world 3D effects, like horizontal refraction, into the model. This study starts with derivations for a 3D variant of Gaussian ray bundles in this coordinate system. To verify the accuracy of this approach, acoustic propagation predictions of transmission loss, time of arrival, and propagation direction are compared to analytic solutions and other models. To validate the model's ability to predict real world phenomena, predictions of transmission loss and propagation direction are compared to at-sea measurements, in an environment where strong horizontal refraction effect have been observed. This model has been integrated into U.S. Navy active sonar training system applications, where testing has demonstrated its ability to improve transmission loss calculation speed without sacrificing accuracy.

  17. Quality Analysis of 3d Surface Reconstruction Using Multi-Platform Photogrammetric Systems

    NASA Astrophysics Data System (ADS)

    Lari, Z.; El-Sheimy, N.

    2016-06-01

    In recent years, the necessity of accurate 3D surface reconstruction has been more pronounced for a wide range of mapping, modelling, and monitoring applications. The 3D data for satisfying the needs of these applications can be collected using different digital imaging systems. Among them, photogrammetric systems have recently received considerable attention due to significant improvements in digital imaging sensors, emergence of new mapping platforms, and development of innovative data processing techniques. To date, a variety of techniques haven been proposed for 3D surface reconstruction using imagery collected by multi-platform photogrammetric systems. However, these approaches suffer from the lack of a well-established quality control procedure which evaluates the quality of reconstructed 3D surfaces independent of the utilized reconstruction technique. Hence, this paper aims to introduce a new quality assessment platform for the evaluation of the 3D surface reconstruction using photogrammetric data. This quality control procedure is performed while considering the quality of input data, processing procedures, and photo-realistic 3D surface modelling. The feasibility of the proposed quality control procedure is finally verified by quality assessment of the 3D surface reconstruction using images from different photogrammetric systems.

  18. Accurate estimation of forest carbon stocks by 3-D remote sensing of individual trees.

    PubMed

    Omasa, Kenji; Qiu, Guo Yu; Watanuki, Kenichi; Yoshimi, Kenji; Akiyama, Yukihide

    2003-03-15

    Forests are one of the most important carbon sinks on Earth. However, owing to the complex structure, variable geography, and large area of forests, accurate estimation of forest carbon stocks is still a challenge for both site surveying and remote sensing. For these reasons, the Kyoto Protocol requires the establishment of methodologies for estimating the carbon stocks of forests (Kyoto Protocol, Article 5). A possible solution to this challenge is to remotely measure the carbon stocks of every tree in an entire forest. Here, we present a methodology for estimating carbon stocks of a Japanese cedar forest by using a high-resolution, helicopter-borne 3-dimensional (3-D) scanning lidar system that measures the 3-D canopy structure of every tree in a forest. Results show that a digital image (10-cm mesh) of woody canopy can be acquired. The treetop can be detected automatically with a reasonable accuracy. The absolute error ranges for tree height measurements are within 42 cm. Allometric relationships of height to carbon stocks then permit estimation of total carbon storage by measurement of carbon stocks of every tree. Thus, we suggest that our methodology can be used to accurately estimate the carbon stocks of Japanese cedar forests at a stand scale. Periodic measurements will reveal changes in forest carbon stocks. PMID:12680675

  19. 3D precision surface measurement by dynamic structured light

    NASA Astrophysics Data System (ADS)

    Franke, Ernest A.; Magee, Michael J.; Mitchell, Joseph N.; Rigney, Michael P.

    2004-02-01

    This paper describes a 3-D imaging technique developed as an internal research project at Southwest Research Institute. The technique is based on an extension of structured light methods in which a projected pattern of parallel lines is rotated over the surface to be measured. A sequence of images is captured and the surface elevation at any location can then be determined from measurements of the temporal pattern, at any point, without considering any other points on the surface. The paper describes techniques for system calibration and surface measurement based on the method of projected quadric shells. Algorithms were developed for image and signal analysis and computer programs were written to calibrate the system and to calculate 3-D coordinates of points on a measured surface. A prototype of the Dynamic Structured Light (DSL) 3-D imaging system was assembled and typical parts were measured. The design procedure was verified and used to implement several different configurations with different measurement volumes and measurement accuracy. A small-parts measurement accuracy of 32 micrometers (.0012") RMS was verified by measuring the surface of a precision-machined plane. Large aircraft control surfaces were measured with a prototype setup that provided .02" depth resolution over a 4" by 8" field of view. Measurement times are typically less than three minutes for 300,000 points. A patent application has been filed.

  20. MR image denoising method for brain surface 3D modeling

    NASA Astrophysics Data System (ADS)

    Zhao, De-xin; Liu, Peng-jie; Zhang, De-gan

    2014-11-01

    Three-dimensional (3D) modeling of medical images is a critical part of surgical simulation. In this paper, we focus on the magnetic resonance (MR) images denoising for brain modeling reconstruction, and exploit a practical solution. We attempt to remove the noise existing in the MR imaging signal and preserve the image characteristics. A wavelet-based adaptive curve shrinkage function is presented in spherical coordinates system. The comparative experiments show that the denoising method can preserve better image details and enhance the coefficients of contours. Using these denoised images, the brain 3D visualization is given through surface triangle mesh model, which demonstrates the effectiveness of the proposed method.

  1. Synthesizing 3D Surfaces from Parameterized Strip Charts

    NASA Technical Reports Server (NTRS)

    Robinson, Peter I.; Gomez, Julian; Morehouse, Michael; Gawdiak, Yuri

    2004-01-01

    We believe 3D information visualization has the power to unlock new levels of productivity in the monitoring and control of complex processes. Our goal is to provide visual methods to allow for rapid human insight into systems consisting of thousands to millions of parameters. We explore this hypothesis in two complex domains: NASA program management and NASA International Space Station (ISS) spacecraft computer operations. We seek to extend a common form of visualization called the strip chart from 2D to 3D. A strip chart can display the time series progression of a parameter and allows for trends and events to be identified. Strip charts can be overlayed when multiple parameters need to visualized in order to correlate their events. When many parameters are involved, the direct overlaying of strip charts can become confusing and may not fully utilize the graphing area to convey the relationships between the parameters. We provide a solution to this problem by generating 3D surfaces from parameterized strip charts. The 3D surface utilizes significantly more screen area to illustrate the differences in the parameters and the overlayed strip charts, and it can rapidly be scanned by humans to gain insight. The selection of the third dimension must be a parallel or parameterized homogenous resource in the target domain, defined using a finite, ordered, enumerated type, and not a heterogeneous type. We demonstrate our concepts with examples from the NASA program management domain (assessing the state of many plans) and the computers of the ISS (assessing the state of many computers). We identify 2D strip charts in each domain and show how to construct the corresponding 3D surfaces. The user can navigate the surface, zooming in on regions of interest, setting a mark and drilling down to source documents from which the data points have been derived. We close by discussing design issues, related work, and implementation challenges.

  2. 3D surface configuration modulates 2D symmetry detection.

    PubMed

    Chen, Chien-Chung; Sio, Lok-Teng

    2015-02-01

    We investigated whether three-dimensional (3D) information in a scene can affect symmetry detection. The stimuli were random dot patterns with 15% dot density. We measured the coherence threshold, or the proportion of dots that were the mirror reflection of the other dots in the other half of the image about a central vertical axis, at 75% accuracy with a 2AFC paradigm under various 3D configurations produced by the disparity between the left and right eye images. The results showed that symmetry detection was difficult when the corresponding dots across the symmetry axis were on different frontoparallel or inclined planes. However, this effect was not due to a difference in distance, as the observers could detect symmetry on a slanted surface, where the depth of the two sides of the symmetric axis was different. The threshold was reduced for a hinge configuration where the join of two slanted surfaces coincided with the axis of symmetry. Our result suggests that the detection of two-dimensional (2D) symmetry patterns is subject to the 3D configuration of the scene; and that coplanarity across the symmetry axis and consistency between the 2D pattern and 3D structure are important factors for symmetry detection. PMID:25536469

  3. In Situ Casting and Imaging of the Rat Airway Tree for Accurate 3D Reconstruction

    SciTech Connect

    Jacob, Rick E.; Colby, Sean M.; Kabilan, Senthil; Einstein, Daniel R.; Carson, James P.

    2013-08-01

    The use of anatomically accurate, animal-specific airway geometries is important for understanding and modeling the physiology of the respiratory system. One approach for acquiring detailed airway architecture is to create a bronchial cast of the conducting airways. However, typical casting procedures either do not faithfully preserve the in vivo branching angles, or produce rigid casts that when removed for imaging are fragile and thus easily damaged. We address these problems by creating an in situ bronchial cast of the conducting airways in rats that can be subsequently imaged in situ using 3D micro-CT imaging. We also demonstrate that deformations in airway branch angles resulting from the casting procedure are small, and that these angle deformations can be reversed through an interactive adjustment of the segmented cast geometry. Animal work was approved by the Institutional Animal Care and Use Committee of Pacific Northwest National Laboratory.

  4. Automated 3D Damaged Cavity Model Builder for Lower Surface Acreage Tile on Orbiter

    NASA Technical Reports Server (NTRS)

    Belknap, Shannon; Zhang, Michael

    2013-01-01

    The 3D Automated Thermal Tool for Damaged Acreage Tile Math Model builder was developed to perform quickly and accurately 3D thermal analyses on damaged lower surface acreage tiles and structures beneath the damaged locations on a Space Shuttle Orbiter. The 3D model builder created both TRASYS geometric math models (GMMs) and SINDA thermal math models (TMMs) to simulate an idealized damaged cavity in the damaged tile(s). The GMMs are processed in TRASYS to generate radiation conductors between the surfaces in the cavity. The radiation conductors are inserted into the TMMs, which are processed in SINDA to generate temperature histories for all of the nodes on each layer of the TMM. The invention allows a thermal analyst to create quickly and accurately a 3D model of a damaged lower surface tile on the orbiter. The 3D model builder can generate a GMM and the correspond ing TMM in one or two minutes, with the damaged cavity included in the tile material. A separate program creates a configuration file, which would take a couple of minutes to edit. This configuration file is read by the model builder program to determine the location of the damage, the correct tile type, tile thickness, structure thickness, and SIP thickness of the damage, so that the model builder program can build an accurate model at the specified location. Once the models are built, they are processed by the TRASYS and SINDA.

  5. Real-time 3D-surface-guided head refixation useful for fractionated stereotactic radiotherapy

    SciTech Connect

    Li Shidong; Liu Dezhi; Yin Gongjie; Zhuang Ping; Geng, Jason

    2006-02-15

    Accurate and precise head refixation in fractionated stereotactic radiotherapy has been achieved through alignment of real-time 3D-surface images with a reference surface image. The reference surface image is either a 3D optical surface image taken at simulation with the desired treatment position, or a CT/MRI-surface rendering in the treatment plan with corrections for patient motion during CT/MRI scans and partial volume effects. The real-time 3D surface images are rapidly captured by using a 3D video camera mounted on the ceiling of the treatment vault. Any facial expression such as mouth opening that affects surface shape and location can be avoided using a new facial monitoring technique. The image artifacts on the real-time surface can generally be removed by setting a threshold of jumps at the neighboring points while preserving detailed features of the surface of interest. Such a real-time surface image, registered in the treatment machine coordinate system, provides a reliable representation of the patient head position during the treatment. A fast automatic alignment between the real-time surface and the reference surface using a modified iterative-closest-point method leads to an efficient and robust surface-guided target refixation. Experimental and clinical results demonstrate the excellent efficacy of <2 min set-up time, the desired accuracy and precision of <1 mm in isocenter shifts, and <1 deg. in rotation.

  6. Molecular cartography of the human skin surface in 3D

    PubMed Central

    Bouslimani, Amina; Porto, Carla; Rath, Christopher M.; Wang, Mingxun; Guo, Yurong; Gonzalez, Antonio; Berg-Lyon, Donna; Ackermann, Gail; Moeller Christensen, Gitte Julie; Nakatsuji, Teruaki; Zhang, Lingjuan; Borkowski, Andrew W.; Meehan, Michael J.; Dorrestein, Kathleen; Gallo, Richard L.; Bandeira, Nuno; Knight, Rob; Alexandrov, Theodore; Dorrestein, Pieter C.

    2015-01-01

    The human skin is an organ with a surface area of 1.5–2 m2 that provides our interface with the environment. The molecular composition of this organ is derived from host cells, microbiota, and external molecules. The chemical makeup of the skin surface is largely undefined. Here we advance the technologies needed to explore the topographical distribution of skin molecules, using 3D mapping of mass spectrometry data and microbial 16S rRNA amplicon sequences. Our 3D maps reveal that the molecular composition of skin has diverse distributions and that the composition is defined not only by skin cells and microbes but also by our daily routines, including the application of hygiene products. The technological development of these maps lays a foundation for studying the spatial relationships of human skin with hygiene, the microbiota, and environment, with potential for developing predictive models of skin phenotypes tailored to individual health. PMID:25825778

  7. Molecular cartography of the human skin surface in 3D.

    PubMed

    Bouslimani, Amina; Porto, Carla; Rath, Christopher M; Wang, Mingxun; Guo, Yurong; Gonzalez, Antonio; Berg-Lyon, Donna; Ackermann, Gail; Moeller Christensen, Gitte Julie; Nakatsuji, Teruaki; Zhang, Lingjuan; Borkowski, Andrew W; Meehan, Michael J; Dorrestein, Kathleen; Gallo, Richard L; Bandeira, Nuno; Knight, Rob; Alexandrov, Theodore; Dorrestein, Pieter C

    2015-04-28

    The human skin is an organ with a surface area of 1.5-2 m(2) that provides our interface with the environment. The molecular composition of this organ is derived from host cells, microbiota, and external molecules. The chemical makeup of the skin surface is largely undefined. Here we advance the technologies needed to explore the topographical distribution of skin molecules, using 3D mapping of mass spectrometry data and microbial 16S rRNA amplicon sequences. Our 3D maps reveal that the molecular composition of skin has diverse distributions and that the composition is defined not only by skin cells and microbes but also by our daily routines, including the application of hygiene products. The technological development of these maps lays a foundation for studying the spatial relationships of human skin with hygiene, the microbiota, and environment, with potential for developing predictive models of skin phenotypes tailored to individual health. PMID:25825778

  8. Design Application Translates 2-D Graphics to 3-D Surfaces

    NASA Technical Reports Server (NTRS)

    2007-01-01

    Fabric Images Inc., specializing in the printing and manufacturing of fabric tension architecture for the retail, museum, and exhibit/tradeshow communities, designed software to translate 2-D graphics for 3-D surfaces prior to print production. Fabric Images' fabric-flattening design process models a 3-D surface based on computer-aided design (CAD) specifications. The surface geometry of the model is used to form a 2-D template, similar to a flattening process developed by NASA's Glenn Research Center. This template or pattern is then applied in the development of a 2-D graphic layout. Benefits of this process include 11.5 percent time savings per project, less material wasted, and the ability to improve upon graphic techniques and offer new design services. Partners include Exhibitgroup/Giltspur (end-user client: TAC Air, a division of Truman Arnold Companies Inc.), Jack Morton Worldwide (end-user client: Nickelodeon), as well as 3D Exhibits Inc., and MG Design Associates Corp.

  9. Direct Orthogonal Distance to Quadratic Surfaces in 3D.

    PubMed

    Lott, Gus K

    2014-09-01

    Discovering the orthogonal distance to a quadratic surface is a classic geometric task in vision, modeling, and robotics. I describe a simple, efficient, and stable direct solution for the orthogonal distance (foot-point) to an arbitrary quadratic surface from a general finite 3D point. The problem is expressed as the intersection of three quadratic surfaces, two of which are derived from the requirement of orthogonality of two non-coincident planes with the tangent plane to the quadric. A sixth order single-variable polynomial is directly generated in one coordinate of the surface point. The method detects intersection points at infinity and operates smoothly across all real quadratic surface classes. The method also geometrically detects continuums of orthogonal points (i.e., from the exact center of a sphere). I discuss algorithm performance, compare it to a state-of-the-art estimator, demonstrate the algorithm on synthetic data, and describe extension to arbitrary dimension. PMID:26352239

  10. Investigation Into the Accuracy of 3D Surface Roughness Characteristics

    NASA Astrophysics Data System (ADS)

    Kumermanis, M.; Rudzitis, J.; Mozga, N.; Ancans, A.; Grislis, A.

    2014-04-01

    The existing standards for surface roughness cover only two dimensions, while in reality this is three-dimensional (3D). In particular, the 3D surface roughness parameters are important for solving the contact surface mechanics problems as related to the accuracy of 3D surface roughness characteristics. One of the most important factors for determination of 3D characteristics is the number of data points (NDP) on the x- and y-axes (i.e. in cut-off length). The NDP has a profound effect on the accuracy of measurement results, measuring time and volume of the output data (especially along the y-axis, where the NDP is identical to the number of parallel profiles). At a too small NDP the results will be incorrect and with too broad scatter, while a too large NDP - though not enlarging the range of basic information - considerably increases the measuring time. Therefore, the aim of the work was to find the optimal NDP for such surface processing methods as grinding, spark erosion and shot methods of surface treatment. Eksistējošie virsmas raupjuma standarti apskata virsmas raupjumu tikai divās dimensijās. Tomēr reālais virsmas raupjums pēc savas dabas ir trīsdimensiju (3D) objekts. Līdz ar to virsmas raupjums ir jāraksturo ar 3D parametriem. Un no šo parametru noteikšanas precizitātes ir atkarīgi tālākie virsmas aprēķini, piemēram, virsmu kontaktēšanās process. Viens no svarīgākajiem faktoriem, raksturojot virsmas raupjumu 3D, pielietojot kontakta tipa mēriekārtas, ir datu punktu skaits pa abām mērīšanas asīm x un y. Ar datu punktu skaitu mēs saprotam to skaitu mērīšanas bāzes garumā. Datu punktu skaits būtiski ietekmē sagaidāmo mērījumu rezultātu precizitāti, mērīšanai nepieciešamo laiku un izejas datu faila izmērus (sevišķi y-ass virzienā, kur katrs datu punkts ir paralēls profils). Datu punktu skaitam ir jābūt optimālam. Pārāk mazs punktu skaits noved pie neprecīziem rezultātiem un lielas to izkliedes, savuk

  11. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    SciTech Connect

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc; Binnekamp, Dirk

    2015-03-15

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

  12. Active illumination based 3D surface reconstruction and registration for image guided medialization laryngoplasty

    NASA Astrophysics Data System (ADS)

    Jin, Ge; Lee, Sang-Joon; Hahn, James K.; Bielamowicz, Steven; Mittal, Rajat; Walsh, Raymond

    2007-03-01

    The medialization laryngoplasty is a surgical procedure to improve the voice function of the patient with vocal fold paresis and paralysis. An image guided system for the medialization laryngoplasty will help the surgeons to accurately place the implant and thus reduce the failure rates of the surgery. One of the fundamental challenges in image guided system is to accurately register the preoperative radiological data to the intraoperative anatomical structure of the patient. In this paper, we present a combined surface and fiducial based registration method to register the preoperative 3D CT data to the intraoperative surface of larynx. To accurately model the exposed surface area, a structured light based stereo vision technique is used for the surface reconstruction. We combined the gray code pattern and multi-line shifting to generate the intraoperative surface of the larynx. To register the point clouds from the intraoperative stage to the preoperative 3D CT data, a shape priori based ICP method is proposed to quickly register the two surfaces. The proposed approach is capable of tracking the fiducial markers and reconstructing the surface of larynx with no damage to the anatomical structure. We used off-the-shelf digital cameras, LCD projector and rapid 3D prototyper to develop our experimental system. The final RMS error in the registration is less than 1mm.

  13. 3D Surface Reconstruction and Volume Calculation of Rills

    NASA Astrophysics Data System (ADS)

    Brings, Christine; Gronz, Oliver; Becker, Kerstin; Wirtz, Stefan; Seeger, Manuel; Ries, Johannes B.

    2015-04-01

    We use the low-cost, user-friendly photogrammetric Structure from Motion (SfM) technique, which is implemented in the Software VisualSfM, for 3D surface reconstruction and volume calculation of an 18 meter long rill in Luxembourg. The images were taken with a Canon HD video camera 1) before a natural rainfall event, 2) after a natural rainfall event and before a rill experiment and 3) after a rill experiment. Recording with a video camera results compared to a photo camera not only a huge time advantage, the method also guarantees more than adequately overlapping sharp images. For each model, approximately 8 minutes of video were taken. As SfM needs single images, we automatically selected the sharpest image from 15 frame intervals. The sharpness was estimated using a derivative-based metric. Then, VisualSfM detects feature points in each image, searches matching feature points in all image pairs, recovers the camera positions and finally by triangulation of camera positions and feature points the software reconstructs a point cloud of the rill surface. From the point cloud, 3D surface models (meshes) are created and via difference calculations of the pre and post models a visualization of the changes (erosion and accumulation areas) and quantification of erosion volumes are possible. The calculated volumes are presented in spatial units of the models and so real values must be converted via references. The outputs are three models at three different points in time. The results show that especially using images taken from suboptimal videos (bad lighting conditions, low contrast of the surface, too much in-motion unsharpness), the sharpness algorithm leads to much more matching features. Hence the point densities of the 3D models are increased and thereby clarify the calculations.

  14. Visualizing 3D velocity fields near contour surfaces

    SciTech Connect

    Max, N.; Crawfis, R.; Grant, C.

    1994-03-01

    Vector field rendering is difficult in 3D because the vector icons overlap and hide each other. We propose four different techniques for visualizing vector fields only near surfaces. The first uses motion blurred particles in a thickened region around the surface. The second uses a voxel grid to contain integral curves of the vector field. The third uses many antialiased lines through the surface, and the fourth uses hairs sprouting from the surface and then bending in the direction of the vector field. All the methods use the graphite pipeline, allowing real time rotation and interaction, and the first two methods can animate the texture to move in the flow determined by the velocity field.

  15. 3D Surface Topology Guides Stem Cell Adhesion and Differentiation

    PubMed Central

    Viswanathan, Priyalakshmi; Ondeck, Matthew G.; Chirasatitsin, Somyot; Nghamkham, Kamolchanok; Reilly, Gwendolen C.; Engler, Adam J.; Battaglia, Giuseppe

    2015-01-01

    Polymerized high internal phase emulsion (polyHIPE) foams are extremely versatile materials for investigating cell-substrate interactions in vitro. Foam morphologies can be controlled by polymerization conditions to result in either open or closed pore structures with different levels of connectivity, consequently enabling the comparison between 2D and 3D matrices using the same substrate with identical surface chemistry conditions. Additionally, here we achieve the control of pore surface topology (i.e. how different ligands are clustered together) using amphiphilic block copolymers as emulsion stabilisers. We demonstrate that adhesion of human mesenchymal progenitor (hES-MP) cells cultured on polyHIPE foams is dependent on foam surface topology and chemistry but is independent of porosity and interconnectivity. We also demonstrate that the interconnectivity, architecture and surface topology of the foams has an effect on the osteogenic differentiation potential of hES-MP cells. Together these data demonstrate that the adhesive heterogeneity of a 3D scaffold could regulate not only mesenchymal stem cell attachment but also cell behavior in the absence of soluble growth factors. PMID:25818420

  16. Effective 3-D surface modeling for geographic information systems

    NASA Astrophysics Data System (ADS)

    Yüksek, K.; Alparslan, M.; Mendi, E.

    2013-11-01

    In this work, we propose a dynamic, flexible and interactive urban digital terrain platform (DTP) with spatial data and query processing capabilities of Geographic Information Systems (GIS), multimedia database functionality and graphical modeling infrastructure. A new data element, called Geo-Node, which stores image, spatial data and 3-D CAD objects is developed using an efficient data structure. The system effectively handles data transfer of Geo-Nodes between main memory and secondary storage with an optimized Directional Replacement Policy (DRP) based buffer management scheme. Polyhedron structures are used in Digital Surface Modeling (DSM) and smoothing process is performed by interpolation. The experimental results show that our framework achieves high performance and works effectively with urban scenes independent from the amount of spatial data and image size. The proposed platform may contribute to the development of various applications such as Web GIS systems based on 3-D graphics standards (e.g. X3-D and VRML) and services which integrate multi-dimensional spatial information and satellite/aerial imagery.

  17. Effective 3-D surface modeling for geographic information systems

    NASA Astrophysics Data System (ADS)

    Yüksek, K.; Alparslan, M.; Mendi, E.

    2016-01-01

    In this work, we propose a dynamic, flexible and interactive urban digital terrain platform with spatial data and query processing capabilities of geographic information systems, multimedia database functionality and graphical modeling infrastructure. A new data element, called Geo-Node, which stores image, spatial data and 3-D CAD objects is developed using an efficient data structure. The system effectively handles data transfer of Geo-Nodes between main memory and secondary storage with an optimized directional replacement policy (DRP) based buffer management scheme. Polyhedron structures are used in digital surface modeling and smoothing process is performed by interpolation. The experimental results show that our framework achieves high performance and works effectively with urban scenes independent from the amount of spatial data and image size. The proposed platform may contribute to the development of various applications such as Web GIS systems based on 3-D graphics standards (e.g., X3-D and VRML) and services which integrate multi-dimensional spatial information and satellite/aerial imagery.

  18. Automatic pose initialization for accurate 2D/3D registration applied to abdominal aortic aneurysm endovascular repair

    NASA Astrophysics Data System (ADS)

    Miao, Shun; Lucas, Joseph; Liao, Rui

    2012-02-01

    Minimally invasive abdominal aortic aneurysm (AAA) stenting can be greatly facilitated by overlaying the preoperative 3-D model of the abdominal aorta onto the intra-operative 2-D X-ray images. Accurate 2-D/3-D registration in 3-D space makes the 2-D/3-D overlay robust to the change of C-Arm angulations. By far, the 2-D/3-D registration methods based on simulated X-ray projection images using multiple image planes have been shown to be able to provide satisfactory 3-D registration accuracy. However, one drawback of the intensity-based 2-D/3-D registration methods is that the similarity measure is usually highly non-convex and hence the optimizer can easily be trapped into local minima. User interaction therefore is often needed in the initialization of the position of the 3-D model in order to get a successful 2-D/3-D registration. In this paper, a novel 3-D pose initialization technique is proposed, as an extension of our previously proposed bi-plane 2-D/3-D registration method for AAA intervention [4]. The proposed method detects vessel bifurcation points and spine centerline in both 2-D and 3-D images, and utilizes landmark information to bring the 3-D volume into a 15mm capture range. The proposed landmark detection method was validated on real dataset, and is shown to be able to provide a good initialization for 2-D/3-D registration in [4], thus making the workflow fully automatic.

  19. An enhanced method for registration of dental surfaces partially scanned by a 3D dental laser scanning.

    PubMed

    Park, Seongjin; Kang, Ho Chul; Lee, Jeongjin; Shin, Juneseuk; Shin, Yeong Gil

    2015-01-01

    In this paper, we propose the fast and accurate registration method of partially scanned dental surfaces in a 3D dental laser scanning. To overcome the multiple point correspondence problems of conventional surface registration methods, we propose the novel depth map-based registration method to register 3D surface models. First, we convert a partially scanned 3D dental surface into a 2D image by generating the 2D depth map image of the surface model by applying a 3D rigid transformation into this model. Then, the image-based registration method using 2D depth map images accurately estimates the initial transformation between two consequently acquired surface models. To further increase the computational efficiency, we decompose the 3D rigid transformation into out-of-plane (i.e. x-, y-rotation, and z-translation) and in-plane (i.e. x-, y-translation, and z-rotation) transformations. For the in-plane transformation, we accelerate the transformation process by transforming the 2D depth map image instead of transforming the 3D surface model. For the more accurate registration of 3D surface models, we enhance iterative closest point (ICP) method for the subsequent fine registration. Our initial depth map-based registration well aligns each surface model. Therefore, our subsequent ICP method can accurately register two surface models since it is highly probable that the closest point pairs are the exact corresponding point pairs. The experimental results demonstrated that our method accurately registered partially scanned dental surfaces. Regarding the computational performance, our method delivered about 1.5 times faster registration than the conventional method. Our method can be successfully applied to the accurate reconstruction of 3D dental objects for orthodontic and prosthodontic treatment. PMID:25453381

  20. Accurate nonrelativistic ground-state energies of 3d transition metal atoms

    SciTech Connect

    Scemama, A.; Applencourt, T.; Giner, E.; Caffarel, M.

    2014-12-28

    We present accurate nonrelativistic ground-state energies of the transition metal atoms of the 3d series calculated with Fixed-Node Diffusion Monte Carlo (FN-DMC). Selected multi-determinantal expansions obtained with the CIPSI (Configuration Interaction using a Perturbative Selection made Iteratively) method and including the most prominent determinants of the full configuration interaction expansion are used as trial wavefunctions. Using a maximum of a few tens of thousands determinants, fixed-node errors on total DMC energies are found to be greatly reduced for some atoms with respect to those obtained with Hartree-Fock nodes. To the best of our knowledge, the FN-DMC/(CIPSI nodes) ground-state energies presented here are the lowest variational total energies reported so far. They differ from the recently recommended non-variational values of McCarthy and Thakkar [J. Chem. Phys. 136, 054107 (2012)] only by a few percents of the correlation energy. Thanks to the variational property of FN-DMC total energies, our results provide exact lower bounds for the absolute value of all-electron correlation energies, |E{sub c}|.

  1. An accurate and efficient 3-D micromagnetic simulation of metal evaporated tape

    NASA Astrophysics Data System (ADS)

    Jones, M.; Miles, J. J.

    1997-07-01

    Metal evaporated tape (MET) has a complex column-like structure in which magnetic domains are arranged randomly. In order to accurately simulate the behaviour of MET it is important to capture these aspects of the material in a high-resolution 3-D micromagnetic model. The scale of this problem prohibits the use of traditional scalar computers and leads us to develop algorithms for a vector processor architecture. We demonstrate that despite the materials highly non-uniform structure, it is possible to develop fast vector algorithms for the computation of the magnetostatic interaction field. We do this by splitting the field calculation into near and far components. The near field component is calculated exactly using an efficient vector algorithm, whereas the far field is calculated approximately using a novel fast Fourier transform (FFT) technique. Results are presented which demonstrate that, in practice, the algorithms require sub-O( N log( N)) computation time. In addition results of highly realistic simulation of hysteresis in MET are presented.

  2. 3D integration of sub-surface photonics with CMOS

    NASA Astrophysics Data System (ADS)

    Jalali, Bahram; Indukuri, Tejaswi; Koonath, Prakash

    2006-02-01

    The integration of photonics and electronics on a single silicon substrate requires technologies that can add optical functionalities without significantly sacrificing valuable wafer area. To this end, we have developed an innovative fabrication process, called SIMOX 3-D Sculpting, that enables monolithic optoelectronic integration in a manner that does not compromise the economics of CMOS manufacturing. In this technique, photonic devices are realized in subsurface silicon layers that are separated from the surface silicon layer by an intervening SiO II layer. The surface silicon layer may then be utilized for electronic circuitry. SIMOX 3-D sculpting involves (1) the implantation of oxygen ions into a patterned silicon substrate followed by (2) high temperature anneal to create buried waveguide-based photonic devices. This process has produced subterranean microresonators with unloaded quality factors of 8000 and extinction ratios >20dB. On the surface silicon layers, MOS transistor structures have been fabricated. The small cross-sectional area of the waveguides lends itself to the realization of nonlinear optical devices. We have previously demonstrated spectral broadening and continuum generation in silicon waveguides utilizing Kerr optical nonlinearity. This may be combined with microresonator filters for on-chip supercontiuum generation and spectral carving. The monolithic integration of CMOS circuits and optical modulators with such multi-wavelength sources represent an exciting avenue for silicon photonics.

  3. Hand surface area estimation formula using 3D anthropometry.

    PubMed

    Hsu, Yao-Wen; Yu, Chi-Yuang

    2010-11-01

    Hand surface area is an important reference in occupational hygiene and many other applications. This study derives a formula for the palm surface area (PSA) and hand surface area (HSA) based on three-dimensional (3D) scan data. Two-hundred and seventy subjects, 135 males and 135 females, were recruited for this study. The hand was measured using a high-resolution 3D hand scanner. Precision and accuracy of the scanner is within 0.67%. Both the PSA and HSA were computed using the triangular mesh summation method. A comparison between this study and previous textbook values (such as in the U.K. teaching text and Lund and Browder chart discussed in the article) was performed first to show that previous textbooks overestimated the PSA by 12.0% and HSA by 8.7% (for the male, PSA 8.5% and HSA 4.7%, and for the female, PSA 16.2% and HSA 13.4%). Six 1D measurements were then extracted semiautomatically for use as candidate estimators for the PSA and HSA estimation formula. Stepwise regressions on these six 1D measurements and variable dependency test were performed. Results show that a pair of measurements (hand length and hand breadth) were able to account for 96% of the HSA variance and up to 98% of the PSA variance. A test of the gender-specific formula indicated that gender is not a significant factor in either the PSA or HSA estimation. PMID:20865628

  4. Brain surface maps from 3-D medical images

    NASA Astrophysics Data System (ADS)

    Lu, Jiuhuai; Hansen, Eric W.; Gazzaniga, Michael S.

    1991-06-01

    The anatomic and functional localization of brain lesions for neurologic diagnosis and brain surgery is facilitated by labeling the cortical surface in 3D images. This paper presents a method which extracts cortical contours from magnetic resonance (MR) image series and then produces a planar surface map which preserves important anatomic features. The resultant map may be used for manual anatomic localization as well as for further automatic labeling. Outer contours are determined on MR cross-sectional images by following the clear boundaries between gray matter and cerebral-spinal fluid, skipping over sulci. Carrying this contour below the surface by shrinking it along its normal produces an inner contour that alternately intercepts gray matter (sulci) and white matter along its length. This procedure is applied to every section in the set, and the image (grayscale) values along the inner contours are radially projected and interpolated onto a semi-cylindrical surface with axis normal to the slices and large enough to cover the whole brain. A planar map of the cortical surface results by flattening this cylindrical surface. The projection from inner contour to cylindrical surface is unique in the sense that different points on the inner contour correspond to different points on the cylindrical surface. As the outer contours are readily obtained by automatic segmentation, cortical maps can be made directly from an MR series.

  5. PROMALS3D web server for accurate multiple protein sequence and structure alignments.

    PubMed

    Pei, Jimin; Tang, Ming; Grishin, Nick V

    2008-07-01

    Multiple sequence alignments are essential in computational sequence and structural analysis, with applications in homology detection, structure modeling, function prediction and phylogenetic analysis. We report PROMALS3D web server for constructing alignments for multiple protein sequences and/or structures using information from available 3D structures, database homologs and predicted secondary structures. PROMALS3D shows higher alignment accuracy than a number of other advanced methods. Input of PROMALS3D web server can be FASTA format protein sequences, PDB format protein structures and/or user-defined alignment constraints. The output page provides alignments with several formats, including a colored alignment augmented with useful information about sequence grouping, predicted secondary structures and consensus sequences. Intermediate results of sequence and structural database searches are also available. The PROMALS3D web server is available at: http://prodata.swmed.edu/promals3d/. PMID:18503087

  6. Conveying the 3D Shape of Transparent Surfaces Via Texture

    NASA Technical Reports Server (NTRS)

    Interrante, Victoria; Fuchs, Henry; Pizer, Stephen

    1997-01-01

    Transparency can be a useful device for depicting multiple overlapping surfaces in a single image. The challenge is to render the transparent surfaces in such a way that their three-dimensional shape can be readily understood and their depth distance from underlying structures clearly perceived. This paper describes our investigations into the use of sparsely-distributed discrete, opaque texture as an 'artistic device' for more explicitly indicating the relative depth of a transparent surface and for communicating the essential features of its 3D shape in an intuitively meaningful and minimally occluding way. The driving application for this work is the visualization of layered surfaces in radiation therapy treatment planning data, and the technique is illustrated on transparent isointensity surfaces of radiation dose. We describe the perceptual motivation and artistic inspiration for defining a stroke texture that is locally oriented in the direction of greatest normal curvature (and in which individual strokes are of a length proportional to the magnitude of the curvature in the direction they indicate), and discuss several alternative methods for applying this texture to isointensity surfaces defined in a volume. We propose an experimental paradigm for objectively measuring observers' ability to judge the shape and depth of a layered transparent surface, in the course of a task relevant to the needs of radiotherapy treatment planning, and use this paradigm to evaluate the practical effectiveness of our approach through a controlled observer experiment based on images generated from actual clinical data.

  7. Depth propagation and surface construction in 3-D vision.

    PubMed

    Georgeson, Mark A; Yates, Tim A; Schofield, Andrew J

    2009-01-01

    In stereo vision, regions with ambiguous or unspecified disparity can acquire perceived depth from unambiguous regions. This has been called stereo capture, depth interpolation or surface completion. We studied some striking induced depth effects suggesting that depth interpolation and surface completion are distinct stages of visual processing. An inducing texture (2-D Gaussian noise) had sinusoidal modulation of disparity, creating a smooth horizontal corrugation. The central region of this surface was replaced by various test patterns whose perceived corrugation was measured. When the test image was horizontal 1-D noise, shown to one eye or to both eyes without disparity, it appeared corrugated in much the same way as the disparity-modulated (DM) flanking regions. But when the test image was 2-D noise, or vertical 1-D noise, little or no depth was induced. This suggests that horizontal orientation was a key factor. For a horizontal sine-wave luminance grating, strong depth was induced, but for a square-wave grating, depth was induced only when its edges were aligned with the peaks and troughs of the DM flanking surface. These and related results suggest that disparity (or local depth) propagates along horizontal 1-D features, and then a 3-D surface is constructed from the depth samples acquired. The shape of the constructed surface can be different from the inducer, and so surface construction appears to operate on the results of a more local depth propagation process. PMID:18977239

  8. THE THOMSON SURFACE. III. TRACKING FEATURES IN 3D

    SciTech Connect

    Howard, T. A.; DeForest, C. E.; Tappin, S. J.; Odstrcil, D.

    2013-03-01

    In this, the final installment in a three-part series on the Thomson surface, we present simulated observations of coronal mass ejections (CMEs) observed by a hypothetical polarizing white light heliospheric imager. Thomson scattering yields a polarization signal that can be exploited to locate observed features in three dimensions relative to the Thomson surface. We consider how the appearance of the CME changes with the direction of trajectory, using simulations of a simple geometrical shape and also of a more realistic CME generated using the ENLIL model. We compare the appearance in both unpolarized B and polarized pB light, and show that there is a quantifiable difference in the measured brightness of a CME between unpolarized and polarized observations. We demonstrate a technique for using this difference to extract the three-dimensional (3D) trajectory of large objects such as CMEs. We conclude with a discussion on how a polarizing heliospheric imager could be used to extract 3D trajectory information about CMEs or other observed features.

  9. Wear Analysis of Thermal Spray Coatings on 3D Surfaces

    NASA Astrophysics Data System (ADS)

    Tillmann, W.; Luo, W.; Selvadurai, U.

    2014-01-01

    Even though the application of thermal spray coatings on complex geometries gained a greater interest in the last decade, the effect of different geometrical features on the wear behavior is still ill-defined. In this study, the wear resistance of FTC-FeCSiMn coated 3D surfaces was investigated. The wear test was carried out by means of two innovative testing procedures. The first test is a Pin-on-Tubes test where the rotating motion is realized by a lathe chuck. The specimens in the second test were fixed on the table and a robot arm operated the pin. This wear test was applied on specimens with concave or convex surfaces. The residual stresses, which were determined by means of an incremental hole-drilling method, show a dependency on the substrate geometry. The obtained stresses were put in relation to the different radii. After the wear test, a 3D-profilometer determined the wear volume and the sections of the coatings were characterized by a scanning electron microscope. The results indicate that the wear resistance is strongly influenced by the geometry of the substrate.

  10. 3D Additive Construction with Regolith for Surface Systems

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.

    2014-01-01

    Planetary surface exploration on Asteroids, the Moon, Mars and Martian Moons will require the stabilization of loose, fine, dusty regolith to avoid the effects of vertical lander rocket plume impingement, to keep abrasive and harmful dust from getting lofted and for dust free operations. In addition, the same regolith stabilization process can be used for 3 Dimensional ( 3D) printing, additive construction techniques by repeating the 2D stabilization in many vertical layers. This will allow in-situ construction with regolith so that materials will not have to be transported from Earth. Recent work in the NASA Kennedy Space Center (KSC) Surface Systems Office (NE-S) Swamp Works and at the University of Southern California (USC) under two NASA Innovative Advanced Concept (NIAC) awards have shown promising results with regolith (crushed basalt rock) materials for in-situ heat shields, bricks, landing/launch pads, berms, roads, and other structures that could be fabricated using regolith that is sintered or mixed with a polymer binder. The technical goals and objectives of this project are to prove the feasibility of 3D printing additive construction using planetary regolith simulants and to show that they have structural integrity and practical applications in space exploration.

  11. 3D stochastic geophysical inversion for contact surface geometry

    NASA Astrophysics Data System (ADS)

    Lelièvre, Peter; Farquharson, Colin; Bijani, Rodrigo

    2015-04-01

    Geologists' interpretations about the Earth typically involve distinct rock units with contacts (interfaces) between them. As such, 3D geological Earth models typically comprise wireframe contact surfaces of tessellated triangles or other polygonal planar facets. In contrast, standard minimum-structure geophysical inversions are performed on meshes of space-filling cells (typically prisms or tetrahedra) and recover smoothly varying physical property distributions that are inconsistent with typical geological interpretations. There are several approaches through which mesh-based geophysical inversion can help recover models with some of the desired characteristics. However, a more effective strategy is to consider a fundamentally different type of inversion that works directly with models that comprise surfaces representing contacts between rock units. We are researching such an approach, our goal being to perform geophysical forward and inverse modelling directly with 3D geological models of any complexity. Geological and geophysical models should be specified using the same parameterization such that they are, in essence, the same Earth model. We parameterize the wireframe contact surfaces in a 3D model as the coordinates of the nodes (facet vertices). The physical properties of each rock unit in a model remain fixed while the geophysical inversion controls the position of the contact surfaces via the control nodes, perturbing the surfaces as required to fit the geophysical data responses. This is essentially a "geometry inversion", which can be used to recover the unknown geometry of a target body or to investigate the viability of a proposed Earth model. We apply global optimization strategies to solve the inverse problem, including stochastic sampling to obtain statistical information regarding the likelihood of particular features in the model, helping to assess the viability of a proposed model. Jointly inverting multiple types of geophysical data is simple

  12. Temperature maps measurements on 3D surfaces with infrared thermography

    NASA Astrophysics Data System (ADS)

    Cardone, Gennaro; Ianiro, Andrea; Dello Ioio, Gennaro; Passaro, Andrea

    2012-02-01

    The use of the infrared camera as a temperature transducer in wind tunnel applications is convenient and widespread. Nevertheless, the infrared data are available in the form of 2D images while the observed surfaces are often not planar and the reconstruction of temperature maps over them is a critical task. In this work, after recalling the principles of IR thermography, a methodology to rebuild temperature maps on the surfaces of 3D object is proposed. In particular, an optical calibration is applied to the IR camera by means of a novel target plate with control points. The proposed procedure takes also into account the directional emissivity by estimating the viewing angle. All the needed steps are described and analyzed. The advantages given by the proposed method are shown with an experiment in a hypersonic wind tunnel.

  13. Machine learning and synthetic aperture refocusing approach for more accurate masking of fish bodies in 3D PIV data

    NASA Astrophysics Data System (ADS)

    Ford, Logan; Bajpayee, Abhishek; Techet, Alexandra

    2015-11-01

    3D particle image velocimetry (PIV) is becoming a popular technique to study biological flows. PIV images that contain fish or other animals around which flow is being studied, need to be appropriately masked in order to remove the animal body from the 3D reconstructed volumes prior to calculating particle displacement vectors. Presented here is a machine learning and synthetic aperture (SA) refocusing based approach for more accurate masking of fish from reconstructed intensity fields for 3D PIV purposes. Using prior knowledge about the 3D shape and appearance of the fish along with SA refocused images at arbitrarily oriented focal planes, the location and orientation of a fish in a reconstructed volume can be accurately determined. Once the location and orientation of a fish in a volume is determined, it can be masked out.

  14. To 3D or Not to 3D, That Is the Question: Do 3D Surface Analyses Improve the Ecomorphological Power of the Distal Femur in Placental Mammals?

    PubMed Central

    Gould, Francois D. H.

    2014-01-01

    Improvements in three-dimensional imaging technologies have renewed interest in the study of functional and ecological morphology. Quantitative approaches to shape analysis are used increasingly to study form-function relationships. These methods are computationally intensive, technically demanding, and time-consuming, which may limit sampling potential. There have been few side-by-side comparisons of the effectiveness of such approaches relative to more traditional analyses using linear measurements and ratios. Morphological variation in the distal femur of mammals has been shown to reflect differences in locomotor modes across clades. Thus I tested whether a geometric morphometric analysis of surface shape was superior to a multivariate analysis of ratios for describing ecomorphological patterns in distal femoral variation. A sample of 164 mammalian specimens from 44 genera was assembled. Each genus was assigned to one of six locomotor categories. The same hypotheses were tested using two methods. Six linear measurements of the distal femur were taken with calipers, from which four ratios were calculated. A 3D model was generated with a laser scanner, and analyzed using three dimensional geometric morphometrics. Locomotor category significantly predicted variation in distal femoral morphology in both analyses. Effect size was larger in the geometric morphometric analysis than in the analysis of ratios. Ordination reveals a similar pattern with arboreal and cursorial taxa as extremes on a continuum of morphologies in both analyses. Discriminant functions calculated from the geometric morphometric analysis were more accurate than those calculated from ratios. Both analysis of ratios and geometric morphometric surface analysis reveal similar, biologically meaningful relationships between distal femoral shape and locomotor mode. The functional signal from the morphology is slightly higher in the geometric morphometric analysis. The practical costs of conducting these

  15. Communication: Accurate hydration free energies at a wide range of temperatures from 3D-RISM.

    PubMed

    Misin, Maksim; Fedorov, Maxim V; Palmer, David S

    2015-03-01

    We present a new model for computing hydration free energies by 3D reference interaction site model (3D-RISM) that uses an appropriate initial state of the system (as suggested by Sergiievskyi et al.). The new adjustment to 3D-RISM theory significantly improves hydration free energy predictions for various classes of organic molecules at both ambient and non-ambient temperatures. An extensive benchmarking against experimental data shows that the accuracy of the model is comparable to (much more computationally expensive) molecular dynamics simulations. The calculations can be readily performed with a standard 3D-RISM algorithm. In our work, we used an open source package AmberTools; a script to automate the whole procedure is available on the web (https://github.com/MTS-Strathclyde/ISc). PMID:25747054

  16. Exact surface registration of retinal surfaces from 3-D optical coherence tomography images.

    PubMed

    Lee, Sieun; Lebed, Evgeniy; Sarunic, Marinko V; Beg, Mirza Faisal

    2015-02-01

    Nonrigid registration of optical coherence tomography (OCT) images is an important problem in studying eye diseases, evaluating the effect of pharmaceuticals in treating vision loss, and performing group-wise cross-sectional analysis. High dimensional nonrigid registration algorithms required for cross-sectional and longitudinal analysis are still being developed for accurate registration of OCT image volumes, with the speckle noise in images presenting a challenge for registration. Development of algorithms for segmentation of OCT images to generate surface models of retinal layers has advanced considerably and several algorithms are now available that can segment retinal OCT images into constituent retinal surfaces. Important morphometric measurements can be extracted if accurate surface registration algorithm for registering retinal surfaces onto corresponding template surfaces were available. In this paper, we present a novel method to perform multiple and simultaneous retinal surface registration, targeted to registering surfaces extracted from ocular volumetric OCT images. This enables a point-to-point correspondence (homology) between template and subject surfaces, allowing for a direct, vertex-wise comparison of morphometric measurements across subject groups. We demonstrate that this approach can be used to localize and analyze regional changes in choroidal and nerve fiber layer thickness among healthy and glaucomatous subjects, allowing for cross-sectional population wise analysis. We also demonstrate the method's ability to track longitudinal changes in optic nerve head morphometry, allowing for within-individual tracking of morphometric changes. This method can also, in the future, be used as a precursor to 3-D OCT image registration to better initialize nonrigid image registration algorithms closer to the desired solution. PMID:25312906

  17. Colored 3D surface reconstruction using Kinect sensor

    NASA Astrophysics Data System (ADS)

    Guo, Lian-peng; Chen, Xiang-ning; Chen, Ying; Liu, Bin

    2015-03-01

    A colored 3D surface reconstruction method which effectively fuses the information of both depth and color image using Microsoft Kinect is proposed and demonstrated by experiment. Kinect depth images are processed with the improved joint-bilateral filter based on region segmentation which efficiently combines the depth and color data to improve its quality. The registered depth data are integrated to achieve a surface reconstruction through the colored truncated signed distance fields presented in this paper. Finally, the improved ray casting for rendering full colored surface is implemented to estimate color texture of the reconstruction object. Capturing the depth and color images of a toy car, the improved joint-bilateral filter based on region segmentation is used to improve the quality of depth images and the peak signal-to-noise ratio (PSNR) is approximately 4.57 dB, which is better than 1.16 dB of the joint-bilateral filter. The colored construction results of toy car demonstrate the suitability and ability of the proposed method.

  18. Surface-Area-Based Attribute Filtering in 3D

    NASA Astrophysics Data System (ADS)

    Kiwanuka, Fred N.; Ouzounis, Georgios K.; Wilkinson, Michael H. F.

    In this paper we describe a rotation-invariant attribute filter based on estimating the sphericity or roundness of objects by efficiently computing surface area and volume of connected components. The method is based on an efficient algorithm to compute all iso-surfaces of all nodes in a Max-Tree. With similar properties to moment-based attributes like sparseness, non-compactness, and elongation, our sphericity attribute can supplement these in finding blood-vessels in time-of-flight MR angiograms. We compare the method to a discrete surface area method based on adjacency, which has been used for urinary stone detection. Though the latter is faster, it is less accurate, and lacks rotation invariance.

  19. Quantifying the surface chemistry of 3D matrices in situ

    NASA Astrophysics Data System (ADS)

    Tzeranis, Dimitrios S.; So, Peter T. C.; Yannas, Ioannis V.

    2014-03-01

    Despite the major role of the matrix (the insoluble environment around cells) in physiology and pathology, there are very few and limited methods that can quantify the surface chemistry of a 3D matrix such as a biomaterial or tissue ECM. This study describes a novel optical-based methodology that can quantify the surface chemistry (density of adhesion ligands for particular cell adhesion receptors) of a matrix in situ. The methodology utilizes fluorescent analogs (markers) of the receptor of interest and a series of binding assays, where the amount of bound markers on the matrix is quantified via spectral multi-photon imaging. The study provides preliminary results for the quantification of the ligands for the two major collagen-binding integrins (α1β1, α2β1) in porous collagen scaffolds that have been shown to be able to induce maximum regeneration in transected peripheral nerves. The developed methodology opens the way for quantitative descriptions of the insoluble microenvironment of cells in physiology and pathology, and for integrating the matrix in quantitative models of cell signaling. α

  20. Reconstructing 3-D skin surface motion for the DIET breast cancer screening system.

    PubMed

    Botterill, Tom; Lotz, Thomas; Kashif, Amer; Chase, J Geoffrey

    2014-05-01

    Digital image-based elasto-tomography (DIET) is a prototype system for breast cancer screening. A breast is imaged while being vibrated, and the observed surface motion is used to infer the internal stiffness of the breast, hence identifying tumors. This paper describes a computer vision system for accurately measuring 3-D surface motion. A model-based segmentation is used to identify the profile of the breast in each image, and the 3-D surface is reconstructed by fitting a model to the profiles. The surface motion is measured using a modern optical flow implementation customized to the application, then trajectories of points on the 3-D surface are given by fusing the optical flow with the reconstructed surfaces. On data from human trials, the system is shown to exceed the performance of an earlier marker-based system at tracking skin surface motion. We demonstrate that the system can detect a 10 mm tumor in a silicone phantom breast. PMID:24770915

  1. 3D Printing of Molecular Potential Energy Surface Models

    ERIC Educational Resources Information Center

    Lolur, Phalgun; Dawes, Richard

    2014-01-01

    Additive manufacturing, commonly known as 3D printing, is gaining popularity in a variety of applications and has recently become routinely available. Today, 3D printing services are not only found in engineering design labs and through online companies, but also in university libraries offering student access. In addition, affordable options for…

  2. 3D active surfaces for liver segmentation in multisequence MRI images.

    PubMed

    Bereciartua, Arantza; Picon, Artzai; Galdran, Adrian; Iriondo, Pedro

    2016-08-01

    Biopsies for diagnosis can sometimes be replaced by non-invasive techniques such as CT and MRI. Surgeons require accurate and efficient methods that allow proper segmentation of the organs in order to ensure the most reliable intervention planning. Automated liver segmentation is a difficult and open problem where CT has been more widely explored than MRI. MRI liver segmentation represents a challenge due to the presence of characteristic artifacts, such as partial volumes, noise and low contrast. In this paper, we present a novel method for multichannel MRI automatic liver segmentation. The proposed method consists of the minimization of a 3D active surface by means of the dual approach to the variational formulation of the underlying problem. This active surface evolves over a probability map that is based on a new compact descriptor comprising spatial and multisequence information which is further modeled by means of a liver statistical model. This proposed 3D active surface approach naturally integrates volumetric regularization in the statistical model. The advantages of the compact visual descriptor together with the proposed approach result in a fast and accurate 3D segmentation method. The method was tested on 18 healthy liver studies and results were compared to a gold standard made by expert radiologists. Comparisons with other state-of-the-art approaches are provided by means of nine well established quality metrics. The obtained results improve these methodologies, achieving a Dice Similarity Coefficient of 98.59. PMID:27282235

  3. Surface modified alginate microcapsules for 3D cell culture

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Wen; Kuo, Chiung Wen; Chueh, Di-Yen; Chen, Peilin

    2016-06-01

    Culture as three dimensional cell aggregates or spheroids can offer an ideal platform for tissue engineering applications and for pharmaceutical screening. Such 3D culture models, however, may suffer from the problems such as immune response and ineffective and cumbersome culture. This paper describes a simple method for producing microcapsules with alginate cores and a thin shell of poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) to encapsulate mouse induced pluripotent stem (miPS) cells, generating a non-fouling surface as an effective immunoisolation barrier. We demonstrated the trapping of the alginate microcapsules in a microwell array for the continuous observation and culture of a large number of encapsulated miPS cells in parallel. miPS cells cultured in the microcapsules survived well and proliferated to form a single cell aggregate. Droplet formation of monodisperse microcapsules with controlled size combined with flow cytometry provided an efficient way to quantitatively analyze the growth of encapsulated cells in a high-throughput manner. The simple and cost-effective coating technique employed to produce the core-shell microcapsules could be used in the emerging field of cell therapy. The microwell array would provide a convenient, user friendly and high-throughput platform for long-term cell culture and monitoring.

  4. Region-Based 3d Surface Reconstruction Using Images Acquired by Low-Cost Unmanned Aerial Systems

    NASA Astrophysics Data System (ADS)

    Lari, Z.; Al-Rawabdeh, A.; He, F.; Habib, A.; El-Sheimy, N.

    2015-08-01

    Accurate 3D surface reconstruction of our environment has become essential for an unlimited number of emerging applications. In the past few years, Unmanned Aerial Systems (UAS) are evolving as low-cost and flexible platforms for geospatial data collection that could meet the needs of aforementioned application and overcome limitations of traditional airborne and terrestrial mobile mapping systems. Due to their payload restrictions, these systems usually include consumer-grade imaging and positioning sensor which will negatively impact the quality of the collected geospatial data and reconstructed surfaces. Therefore, new surface reconstruction surfaces are needed to mitigate the impact of using low-cost sensors on the final products. To date, different approaches have been proposed to for 3D surface construction using overlapping images collected by imaging sensor mounted on moving platforms. In these approaches, 3D surfaces are mainly reconstructed based on dense matching techniques. However, generated 3D point clouds might not accurately represent the scanned surfaces due to point density variations and edge preservation problems. In order to resolve these problems, a new region-based 3D surface renostruction trchnique is introduced in this paper. This approach aims to generate a 3D photo-realistic model of individually scanned surfaces within the captured images. This approach is initiated by a Semi-Global dense Matching procedure is carried out to generate a 3D point cloud from the scanned area within the collected images. The generated point cloud is then segmented to extract individual planar surfaces. Finally, a novel region-based texturing technique is implemented for photorealistic reconstruction of the extracted planar surfaces. Experimental results using images collected by a camera mounted on a low-cost UAS demonstrate the feasibility of the proposed approach for photorealistic 3D surface reconstruction.

  5. Dynamics of tokamak plasma surface current in 3D ideal MHD model

    NASA Astrophysics Data System (ADS)

    Galkin, Sergei A.; Svidzinski, V. A.; Zakharov, L. E.

    2013-10-01

    Interest in the surface current which can arise on perturbed sharp plasma vacuum interface in tokamaks was recently generated by a few papers (see and references therein). In dangerous disruption events with plasma-touching-wall scenarios, the surface current can be shared with the wall leading to the strong, damaging forces acting on the wall A relatively simple analytic definition of δ-function surface current proportional to a jump of tangential component of magnetic field nevertheless leads to a complex computational problem on the moving plasma-vacuum interface, requiring the incorporation of non-linear 3D plasma dynamics even in one-fluid ideal MHD. The Disruption Simulation Code (DSC), which had recently been developed in a fully 3D toroidal geometry with adaptation to the moving plasma boundary, is an appropriate tool for accurate self-consistent δfunction surface current calculation. Progress on the DSC-3D development will be presented. Self-consistent surface current calculation under non-linear dynamics of low m kink mode and VDE will be discussed. Work is supported by the US DOE SBIR grant #DE-SC0004487.

  6. Hipparcos makes an accurate 3-D chart of an important star cluster

    NASA Astrophysics Data System (ADS)

    1998-02-01

    Star clusters are crucial for understanding the lives of the stars everywhere, because all the members of a cluster formed at the same time from the same raw materials. Astrophysicists can see how the evolution of each star depends on its mass and chemical composition. The heavier a star is, the more intensely it burns and the faster it consumes its thermonuclear fuel. But the accuracy of the theories has been limited hitherto by inaccuracies in the observations. The brightest members of Hyades are visible to the naked eye, in the constellation Taurus. As the nearest moderately rich star cluster, the Hyades have loomed large in astrophysics for more than a century. Contradictory results for the distance of the star cluster left big question marks for the theorists, and even recent observations with the Hubble Space Telescope seemed only to deepen the mystery. Astronomers from ESA, Leiden Observatory, Observatoire de Paris-Meudon, University of Lausanne and Observatoire de la Côte d'Azur joined forces to analyse the data on the Hyades cluster contained in the Hipparcos Catalogue published last year. Their results will appear in the March issue of the European journal Astronomy & Astrophysics. The distance to the centre of the Hyades cluster is 151 light-years (46.34 parsecs) with an uncertainty of less than one light-year (0.27 parsec). From astrophysical theory the astronomers can date the birth of the Hyades at 625 million years ago, when only the most primitive animals lived on the Earth. The cluster has done well to survive so long.The individual stars of the Hyades are bound together by the gravity of the cluster as a whole, and their collective and individual motions are also plotted by Hipparcos. The result is a crisp 3-D motion picture of the cluster. An animation is available on the Internet (see note below). Outlying members sharing the same general motion can now be added to the Hyades tribe, while other candidate members are rejected on grounds of

  7. SU-F-BRF-08: Conformal Mapping-Based 3D Surface Matching and Registration

    SciTech Connect

    Song, Y; Zeng, W; Gu, X; Liu, C

    2014-06-15

    Purpose: Recently, non-rigid 3D surface matching and registration has been used extensively in engineering and medicine. However, matching 3D surfaces undergoing non-rigid deformation accurately is still a challenging mathematical problem. In this study, we present a novel algorithm to address this issue by introducing intrinsic symmetry to the registration Methods: Our computational algorithm for symmetric conformal mapping is divided into three major steps: 1) Finding the symmetric plane; 2) Finding feature points; and 3) Performing cross registration. The key strategy is to preserve the symmetry during the conformal mapping, such that the image on the parameter domain is symmetric and the area distortion factor on the parameter image is also symmetric. Several novel algorithms were developed using different conformal geometric tools. One was based on solving Riemann-Cauchy equation and the other one employed curvature flow Results: Our algorithm was implemented using generic C++ on Windows XP and used conjugate gradient search optimization for acceleration. The human face 3D surface images were acquired using a high speed 3D scanner based on the phase-shifting method. The scanning speed was 30 frames/sec. The image resolution for each frame was 640 × 480. For 3D human face surfaces with different expressions, postures, and boundaries, our algorithms were able to produce consistent result on the texture pattern on the overlapping region Conclusion: We proposed a novel algorithm to improve the robustness of conformal geometric methods by incorporating the symmetric information into the mapping process. To objectively evaluate its performance, we compared it with most existing techniques. Experimental results indicated that our method outperformed all the others in terms of robustness. The technique has a great potential in real-time patient monitoring and tracking in image-guided radiation therapy.

  8. Surface strain-field determination of tympanic membrane using 3D-digital holographic interferometry

    NASA Astrophysics Data System (ADS)

    Hernandez-Montes, María del S.; Mendoza Santoyo, Fernando; Muñoz, Silvino; Perez, Carlos; de la Torre, Manuel; Flores, Mauricio; Alvarez, Luis

    2015-08-01

    In order to increase the understanding of soft tissues mechanical properties, 3D Digital Holographic Interferometry (3D-DHI) was used to quantify the strain-field on a cat tympanic membrane (TM) surface. The experiments were carried out applying a constant sound-stimuli pressure of 90 dB SPL (0.632 Pa) on the TM at 1.2 kHz. The technique allows the accurate acquisition of the micro-displacement data along the x, y and z directions, which is a must for a full characterization of the tissue mechanical behavior under load, and for the calculation of the strain-field in situ. The displacements repeatability in z direction shows a standard deviation of 0.062 μm at 95% confidence level. In order to realize the full 3D characterization correctly the contour of the TM surface was measured employing the optically non-contact two-illumination positions contouring method. The x, y and z displacements combined with the TM contour data allow the evaluation its strain-field by spatially differentiating the u(m,n), v(m,n), and w(m,n) deformation components. The accurate and correct determination of the TM strain-field leads to describing its elasticity, which is an important parameter needed to improve ear biomechanics studies, audition processes and TM mobility in both experimental measurements and theoretical analysis of ear functionality and its modeling.

  9. Quick, Accurate, Smart: 3D Computer Vision Technology Helps Assessing Confined Animals’ Behaviour

    PubMed Central

    Calderara, Simone; Pistocchi, Simone; Cucchiara, Rita; Podaliri-Vulpiani, Michele; Messori, Stefano; Ferri, Nicola

    2016-01-01

    Mankind directly controls the environment and lifestyles of several domestic species for purposes ranging from production and research to conservation and companionship. These environments and lifestyles may not offer these animals the best quality of life. Behaviour is a direct reflection of how the animal is coping with its environment. Behavioural indicators are thus among the preferred parameters to assess welfare. However, behavioural recording (usually from video) can be very time consuming and the accuracy and reliability of the output rely on the experience and background of the observers. The outburst of new video technology and computer image processing gives the basis for promising solutions. In this pilot study, we present a new prototype software able to automatically infer the behaviour of dogs housed in kennels from 3D visual data and through structured machine learning frameworks. Depth information acquired through 3D features, body part detection and training are the key elements that allow the machine to recognise postures, trajectories inside the kennel and patterns of movement that can be later labelled at convenience. The main innovation of the software is its ability to automatically cluster frequently observed temporal patterns of movement without any pre-set ethogram. Conversely, when common patterns are defined through training, a deviation from normal behaviour in time or between individuals could be assessed. The software accuracy in correctly detecting the dogs’ behaviour was checked through a validation process. An automatic behaviour recognition system, independent from human subjectivity, could add scientific knowledge on animals’ quality of life in confinement as well as saving time and resources. This 3D framework was designed to be invariant to the dog’s shape and size and could be extended to farm, laboratory and zoo quadrupeds in artificial housing. The computer vision technique applied to this software is innovative in non

  10. Quick, Accurate, Smart: 3D Computer Vision Technology Helps Assessing Confined Animals' Behaviour.

    PubMed

    Barnard, Shanis; Calderara, Simone; Pistocchi, Simone; Cucchiara, Rita; Podaliri-Vulpiani, Michele; Messori, Stefano; Ferri, Nicola

    2016-01-01

    Mankind directly controls the environment and lifestyles of several domestic species for purposes ranging from production and research to conservation and companionship. These environments and lifestyles may not offer these animals the best quality of life. Behaviour is a direct reflection of how the animal is coping with its environment. Behavioural indicators are thus among the preferred parameters to assess welfare. However, behavioural recording (usually from video) can be very time consuming and the accuracy and reliability of the output rely on the experience and background of the observers. The outburst of new video technology and computer image processing gives the basis for promising solutions. In this pilot study, we present a new prototype software able to automatically infer the behaviour of dogs housed in kennels from 3D visual data and through structured machine learning frameworks. Depth information acquired through 3D features, body part detection and training are the key elements that allow the machine to recognise postures, trajectories inside the kennel and patterns of movement that can be later labelled at convenience. The main innovation of the software is its ability to automatically cluster frequently observed temporal patterns of movement without any pre-set ethogram. Conversely, when common patterns are defined through training, a deviation from normal behaviour in time or between individuals could be assessed. The software accuracy in correctly detecting the dogs' behaviour was checked through a validation process. An automatic behaviour recognition system, independent from human subjectivity, could add scientific knowledge on animals' quality of life in confinement as well as saving time and resources. This 3D framework was designed to be invariant to the dog's shape and size and could be extended to farm, laboratory and zoo quadrupeds in artificial housing. The computer vision technique applied to this software is innovative in non

  11. Simultaneous, accurate measurement of the 3D position and orientation of single molecules

    PubMed Central

    Backlund, Mikael P.; Lew, Matthew D.; Backer, Adam S.; Sahl, Steffen J.; Grover, Ginni; Agrawal, Anurag; Piestun, Rafael; Moerner, W. E.

    2012-01-01

    Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule’s 3D orientation and z position. Failure to account for this fact can lead to significant lateral (x, y) mislocalizations (up to ∼50–200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from ∼2× worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (∼4× worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit). PMID:23129640

  12. A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system

    SciTech Connect

    Liu, Wenyang; Cheung, Yam; Sabouri, Pouya; Arai, Tatsuya J.; Sawant, Amit; Ruan, Dan

    2015-11-15

    achieved submillimeter reconstruction RMSE under different configurations, demonstrating quantitatively the faith of the proposed method in preserving local structural properties of the underlying surface in the presence of noise and missing measurements, and its robustness toward variations of such characteristics. On point clouds from the human subject, the proposed method successfully reconstructed all patient surfaces, filling regions where raw point coordinate readings were missing. Within two comparable regions of interest in the chest area, similar mean curvature distributions were acquired from both their reconstructed surface and CT surface, with mean and standard deviation of (μ{sub recon} = − 2.7 × 10{sup −3} mm{sup −1}, σ{sub recon} = 7.0 × 10{sup −3} mm{sup −1}) and (μ{sub CT} = − 2.5 × 10{sup −3} mm{sup −1}, σ{sub CT} = 5.3 × 10{sup −3} mm{sup −1}), respectively. The agreement of local geometry properties between the reconstructed surfaces and the CT surface demonstrated the ability of the proposed method in faithfully representing the underlying patient surface. Conclusions: The authors have integrated and developed an accurate level-set based continuous surface reconstruction method on point clouds acquired by a 3D surface photogrammetry system. The proposed method has generated a continuous representation of the underlying phantom and patient surfaces with good robustness against noise and missing measurements. It serves as an important first step for further development of motion tracking methods during radiotherapy.

  13. Accurate, finite-volume methods for 3D MHD on unstructured Lagrangian meshes

    SciTech Connect

    Barnes, D.C.; Rousculp, C.L.

    1998-10-01

    Previous 2D methods for magnetohydrodynamics (MHD) have contributed both to development of core code capability and to physics applications relevant to AGEX pulsed-power experiments. This strategy is being extended to 3D by development of a modular extension of an ASCI code. Extension to 3D not only increases complexity by problem size, but also introduces new physics, such as magnetic helicity transport. The authors have developed a method which incorporates all known conservation properties into the difference scheme on a Lagrangian unstructured mesh. Because the method does not depend on the mesh structure, mesh refinement is possible during a calculation to prevent the well known problem of mesh tangling. Arbitrary polyhedral cells are decomposed into tetrahedrons. The action of the magnetic vector potential, A {center_dot} {delta}l, is centered on the edges of this extended mesh. For ideal flow, this maintains {del} {center_dot} B = 0 to round-off error. Vertex forces are derived by the variation of magnetic energy with respect to vertex positions, F = {minus}{partial_derivative}W{sub B}/{partial_derivative}r. This assures symmetry as well as magnetic flux, momentum, and energy conservation. The method is local so that parallelization by domain decomposition is natural for large meshes. In addition, a simple, ideal-gas, finite pressure term has been included. The resistive diffusion part is calculated using the support operator method, to obtain an energy conservative, symmetric method on an arbitrary mesh. Implicit time difference equations are solved by preconditioned, conjugate gradient methods. Results of convergence tests are presented. Initial results of an annular Z-pinch implosion problem illustrate the application of these methods to multi-material problems.

  14. In vivo bioluminescence tomography based on multi-view projection and 3D surface reconstruction

    NASA Astrophysics Data System (ADS)

    Zhang, Shuang; Wang, Kun; Leng, Chengcai; Deng, Kexin; Hu, Yifang; Tian, Jie

    2015-03-01

    Bioluminescence tomography (BLT) is a powerful optical molecular imaging modality, which enables non-invasive realtime in vivo imaging as well as 3D quantitative analysis in preclinical studies. In order to solve the inverse problem and reconstruct inner light sources accurately, the prior structural information is commonly necessary and obtained from computed tomography or magnetic resonance imaging. This strategy requires expensive hybrid imaging system, complicated operation protocol and possible involvement of ionizing radiation. The overall robustness highly depends on the fusion accuracy between the optical and structural information. In this study we present a pure optical bioluminescence tomographic system (POBTS) and a novel BLT method based on multi-view projection acquisition and 3D surface reconstruction. The POBTS acquired a sparse set of white light surface images and bioluminescent images of a mouse. Then the white light images were applied to an approximate surface model to generate a high quality textured 3D surface reconstruction of the mouse. After that we integrated multi-view luminescent images based on the previous reconstruction, and applied an algorithm to calibrate and quantify the surface luminescent flux in 3D.Finally, the internal bioluminescence source reconstruction was achieved with this prior information. A BALB/C mouse with breast tumor of 4T1-fLuc cells mouse model were used to evaluate the performance of the new system and technique. Compared with the conventional hybrid optical-CT approach using the same inverse reconstruction method, the reconstruction accuracy of this technique was improved. The distance error between the actual and reconstructed internal source was decreased by 0.184 mm.

  15. Importance of a 3D forward modeling tool for surface wave analysis methods

    NASA Astrophysics Data System (ADS)

    Pageot, Damien; Le Feuvre, Mathieu; Donatienne, Leparoux; Philippe, Côte; Yann, Capdeville

    2016-04-01

    Since a few years, seismic surface waves analysis methods (SWM) have been widely developed and tested in the context of subsurface characterization and have demonstrated their effectiveness for sounding and monitoring purposes, e.g., high-resolution tomography of the principal geological units of California or real time monitoring of the Piton de la Fournaise volcano. Historically, these methods are mostly developed under the assumption of semi-infinite 1D layered medium without topography. The forward modeling is generally based on Thomson-Haskell matrix based modeling algorithm and the inversion is driven by Monte-Carlo sampling. Given their efficiency, SWM have been transfered to several scale of which civil engineering structures in order to, e.g., determine the so-called V s30 parameter or assess other critical constructional parameters in pavement engineering. However, at this scale, many structures may often exhibit 3D surface variations which drastically limit the efficiency of SWM application. Indeed, even in the case of an homogeneous structure, 3D geometry can bias the dispersion diagram of Rayleigh waves up to obtain discontinuous phase velocity curves which drastically impact the 1D mean velocity model obtained from dispersion inversion. Taking advantages of high-performance computing center accessibility and wave propagation modeling algorithm development, it is now possible to consider the use of a 3D elastic forward modeling algorithm instead of Thomson-Haskell method in the SWM inversion process. We use a parallelized 3D elastic modeling code based on the spectral element method which allows to obtain accurate synthetic data with very low numerical dispersion and a reasonable numerical cost. In this study, we choose dike embankments as an illustrative example. We first show that their longitudinal geometry may have a significant effect on dispersion diagrams of Rayleigh waves. Then, we demonstrate the necessity of 3D elastic modeling as a forward

  16. Ghost Particle Velocimetry: Accurate 3D Flow Visualization Using Standard Lab Equipment

    NASA Astrophysics Data System (ADS)

    Buzzaccaro, Stefano; Secchi, Eleonora; Piazza, Roberto

    2013-07-01

    We describe and test a new approach to particle velocimetry, based on imaging and cross correlating the scattering speckle pattern generated on a near-field plane by flowing tracers with a size far below the diffraction limit, which allows reconstructing the velocity pattern in microfluidic channels without perturbing the flow. As a matter of fact, adding tracers is not even strictly required, provided that the sample displays sufficiently refractive-index fluctuations. For instance, phase separation in liquid mixtures in the presence of shear is suitable to be directly investigated by this “ghost particle velocimetry” technique, which just requires a microscope with standard lamp illumination equipped with a low-cost digital camera. As a further bonus, the peculiar spatial coherence properties of the illuminating source, which displays a finite longitudinal coherence length, allows for a 3D reconstruction of the profile with a resolution of few tenths of microns and makes the technique suitable to investigate turbid samples with negligible multiple scattering effects.

  17. Prognostic breast cancer signature identified from 3D culture model accurately predicts clinical outcome across independent datasets

    SciTech Connect

    Martin, Katherine J.; Patrick, Denis R.; Bissell, Mina J.; Fournier, Marcia V.

    2008-10-20

    One of the major tenets in breast cancer research is that early detection is vital for patient survival by increasing treatment options. To that end, we have previously used a novel unsupervised approach to identify a set of genes whose expression predicts prognosis of breast cancer patients. The predictive genes were selected in a well-defined three dimensional (3D) cell culture model of non-malignant human mammary epithelial cell morphogenesis as down-regulated during breast epithelial cell acinar formation and cell cycle arrest. Here we examine the ability of this gene signature (3D-signature) to predict prognosis in three independent breast cancer microarray datasets having 295, 286, and 118 samples, respectively. Our results show that the 3D-signature accurately predicts prognosis in three unrelated patient datasets. At 10 years, the probability of positive outcome was 52, 51, and 47 percent in the group with a poor-prognosis signature and 91, 75, and 71 percent in the group with a good-prognosis signature for the three datasets, respectively (Kaplan-Meier survival analysis, p<0.05). Hazard ratios for poor outcome were 5.5 (95% CI 3.0 to 12.2, p<0.0001), 2.4 (95% CI 1.6 to 3.6, p<0.0001) and 1.9 (95% CI 1.1 to 3.2, p = 0.016) and remained significant for the two larger datasets when corrected for estrogen receptor (ER) status. Hence the 3D-signature accurately predicts breast cancer outcome in both ER-positive and ER-negative tumors, though individual genes differed in their prognostic ability in the two subtypes. Genes that were prognostic in ER+ patients are AURKA, CEP55, RRM2, EPHA2, FGFBP1, and VRK1, while genes prognostic in ER patients include ACTB, FOXM1 and SERPINE2 (Kaplan-Meier p<0.05). Multivariable Cox regression analysis in the largest dataset showed that the 3D-signature was a strong independent factor in predicting breast cancer outcome. The 3D-signature accurately predicts breast cancer outcome across multiple datasets and holds prognostic

  18. Detailed and Highly Accurate 3d Models of High Mountain Areas by the Macs-Himalaya Aerial Camera Platform

    NASA Astrophysics Data System (ADS)

    Brauchle, J.; Hein, D.; Berger, R.

    2015-04-01

    Remote sensing in areas with extreme altitude differences is particularly challenging. In high mountain areas specifically, steep slopes result in reduced ground pixel resolution and degraded quality in the DEM. Exceptionally high brightness differences can in part no longer be imaged by the sensors. Nevertheless, detailed information about mountainous regions is highly relevant: time and again glacier lake outburst floods (GLOFs) and debris avalanches claim dozens of victims. Glaciers are sensitive to climate change and must be carefully monitored. Very detailed and accurate 3D maps provide a basic tool for the analysis of natural hazards and the monitoring of glacier surfaces in high mountain areas. There is a gap here, because the desired accuracies are often not achieved. It is for this reason that the DLR Institute of Optical Sensor Systems has developed a new aerial camera, the MACS-Himalaya. The measuring unit comprises four camera modules with an overall aperture angle of 116° perpendicular to the direction of flight. A High Dynamic Range (HDR) mode was introduced so that within a scene, bright areas such as sun-flooded snow and dark areas such as shaded stone can be imaged. In 2014, a measuring survey was performed on the Nepalese side of the Himalayas. The remote sensing system was carried by a Stemme S10 motor glider. Amongst other targets, the Seti Valley, Kali-Gandaki Valley and the Mt. Everest/Khumbu Region were imaged at heights up to 9,200 m. Products such as dense point clouds, DSMs and true orthomosaics with a ground pixel resolution of up to 15 cm were produced. Special challenges and gaps in the investigation of high mountain areas, approaches for resolution of these problems, the camera system and the state of evaluation are presented with examples.

  19. 3D SEM for surface topography quantification - a case study on dental surfaces

    NASA Astrophysics Data System (ADS)

    Glon, F.; Flys, O.; Lööf, P.-J.; Rosén, B.-G.

    2014-03-01

    3D analysis of surface topography is becoming a more used tool for industry and research. New ISO standards are being launched to assist in quantifying engineering surfaces. The traditional optical measuring instrumentation used for 3D surface characterization has been optical interferometers and confocal based instrumentation. However, the resolution here is limited in the lateral dimension to the wavelength of visible light to about 500 nm. The great advantage using the SEM for topography measurements is the high flexibility to zoom from low magnifications and locating interesting areas to high magnification of down to nanometer large surface features within seconds. This paper presents surface characterization of dental implant micro topography. 3D topography data was created from SEM images using commercial photogrammetric software. A coherence scanning interferometer was used for reference measurements to compare with the 3D SEM measurements on relocated areas. As a result of this study, measurements emphasizes that the correlation between the accepted CSI measurements and the new technology represented by photogrammetry based on SEM images for many areal characterization parameters are around or less than 20%. The importance of selecting sampling and parameter sensitivity to varying sampling is high-lighted. Future work includes a broader study of limitations of the photogrammetry technique on certified micro-geometries and more application surfaces at different scales.

  20. Accurate 3-D finite difference computation of traveltimes in strongly heterogeneous media

    NASA Astrophysics Data System (ADS)

    Noble, M.; Gesret, A.; Belayouni, N.

    2014-12-01

    Seismic traveltimes and their spatial derivatives are the basis of many imaging methods such as pre-stack depth migration and tomography. A common approach to compute these quantities is to solve the eikonal equation with a finite-difference scheme. If many recently published algorithms for resolving the eikonal equation do now yield fairly accurate traveltimes for most applications, the spatial derivatives of traveltimes remain very approximate. To address this accuracy issue, we develop a new hybrid eikonal solver that combines a spherical approximation when close to the source and a plane wave approximation when far away. This algorithm reproduces properly the spherical behaviour of wave fronts in the vicinity of the source. We implement a combination of 16 local operators that enables us to handle velocity models with sharp vertical and horizontal velocity contrasts. We associate to these local operators a global fast sweeping method to take into account all possible directions of wave propagation. Our formulation allows us to introduce a variable grid spacing in all three directions of space. We demonstrate the efficiency of this algorithm in terms of computational time and the gain in accuracy of the computed traveltimes and their derivatives on several numerical examples.

  1. Accurate gradient approximation for complex interface problems in 3D by an improved coupling interface method

    NASA Astrophysics Data System (ADS)

    Shu, Yu-Chen; Chern, I.-Liang; Chang, Chien C.

    2014-10-01

    Most elliptic interface solvers become complicated for complex interface problems at those “exceptional points” where there are not enough neighboring interior points for high order interpolation. Such complication increases especially in three dimensions. Usually, the solvers are thus reduced to low order accuracy. In this paper, we classify these exceptional points and propose two recipes to maintain order of accuracy there, aiming at improving the previous coupling interface method [26]. Yet the idea is also applicable to other interface solvers. The main idea is to have at least first order approximations for second order derivatives at those exceptional points. Recipe 1 is to use the finite difference approximation for the second order derivatives at a nearby interior grid point, whenever this is possible. Recipe 2 is to flip domain signatures and introduce a ghost state so that a second-order method can be applied. This ghost state is a smooth extension of the solution at the exceptional point from the other side of the interface. The original state is recovered by a post-processing using nearby states and jump conditions. The choice of recipes is determined by a classification scheme of the exceptional points. The method renders the solution and its gradient uniformly second-order accurate in the entire computed domain. Numerical examples are provided to illustrate the second order accuracy of the presently proposed method in approximating the gradients of the original states for some complex interfaces which we had tested previous in two and three dimensions, and a real molecule (1D63) which is double-helix shape and composed of hundreds of atoms.

  2. Accurate gradient approximation for complex interface problems in 3D by an improved coupling interface method

    SciTech Connect

    Shu, Yu-Chen; Chern, I-Liang; Chang, Chien C.

    2014-10-15

    Most elliptic interface solvers become complicated for complex interface problems at those “exceptional points” where there are not enough neighboring interior points for high order interpolation. Such complication increases especially in three dimensions. Usually, the solvers are thus reduced to low order accuracy. In this paper, we classify these exceptional points and propose two recipes to maintain order of accuracy there, aiming at improving the previous coupling interface method [26]. Yet the idea is also applicable to other interface solvers. The main idea is to have at least first order approximations for second order derivatives at those exceptional points. Recipe 1 is to use the finite difference approximation for the second order derivatives at a nearby interior grid point, whenever this is possible. Recipe 2 is to flip domain signatures and introduce a ghost state so that a second-order method can be applied. This ghost state is a smooth extension of the solution at the exceptional point from the other side of the interface. The original state is recovered by a post-processing using nearby states and jump conditions. The choice of recipes is determined by a classification scheme of the exceptional points. The method renders the solution and its gradient uniformly second-order accurate in the entire computed domain. Numerical examples are provided to illustrate the second order accuracy of the presently proposed method in approximating the gradients of the original states for some complex interfaces which we had tested previous in two and three dimensions, and a real molecule ( (1D63)) which is double-helix shape and composed of hundreds of atoms.

  3. i3DP, a robust 3D printing approach enabling genetic post-printing surface modification.

    PubMed

    Wang, Xiaolong; Cai, Xiaobing; Guo, Qiuquan; Zhang, Tengyuan; Kobe, Brad; Yang, Jun

    2013-10-01

    Initiator integrated 3D printing, namely i3DP, was developed by incorporating a vinyl-terminated initiator into UV curable resin to make functional structural materials that enable genetic post-printing surface-initiated modification. Taking advantage of 3D printing and surface-initiated ATRP, the feasible i3DP makes 3D printed complex architectures possible for nearly any desired surface modification for various applications, for example, even pouring water into a sieve was readily achieved. PMID:24002351

  4. Parameterized code SHARM-3D for radiative transfer over inhomogeneous surfaces

    NASA Astrophysics Data System (ADS)

    Lyapustin, Alexei; Wang, Yujie

    2005-12-01

    The code SHARM-3D, developed for fast and accurate simulations of the monochromatic radiance at the top of the atmosphere over spatially variable surfaces with Lambertian or anisotropic reflectance, is described. The atmosphere is assumed to be laterally uniform across the image and to consist of two layers with aerosols contained in the bottom layer. The SHARM-3D code performs simultaneous calculations for all specified incidence-view geometries and multiple wavelengths in one run. The numerical efficiency of the current version of code is close to its potential limit and is achieved by means of two innovations. The first is the development of a comprehensive precomputed lookup table of the three-dimensional atmospheric optical transfer function for various atmospheric conditions. The second is the use of a linear kernel model of the land surface bidirectional reflectance factor (BRF) in our algorithm that has led to a fully parameterized solution in terms of the surface BRF parameters. The code is also able to model inland lakes and rivers. The water pixels are described with the Nakajima-Tanaka BRF model of wind-roughened water surface with a Lambertian offset, which is designed to model approximately the reflectance of suspended matter and of a shallow lake or river bottom.

  5. Evolution of 3D surface imaging systems in facial plastic surgery.

    PubMed

    Tzou, Chieh-Han John; Frey, Manfred

    2011-11-01

    Recent advancements in computer technologies have propelled the development of 3D imaging systems. 3D surface-imaging is taking surgeons to a new level of communication with patients; moreover, it provides quick and standardized image documentation. This article recounts the chronologic evolution of 3D surface imaging, and summarizes the current status of today's facial surface capturing technology. This article also discusses current 3D surface imaging hardware and software, and their different techniques, technologies, and scientific validation, which provides surgeons with the background information necessary for evaluating the systems and knowledge about the systems they might incorporate into their own practice. PMID:22004854

  6. Fast 3D Surface Extraction 2 pages (including abstract)

    SciTech Connect

    Sewell, Christopher Meyer; Patchett, John M.; Ahrens, James P.

    2012-06-05

    Ocean scientists searching for isosurfaces and/or thresholds of interest in high resolution 3D datasets required a tedious and time-consuming interactive exploration experience. PISTON research and development activities are enabling ocean scientists to rapidly and interactively explore isosurfaces and thresholds in their large data sets using a simple slider with real time calculation and visualization of these features. Ocean Scientists can now visualize more features in less time, helping them gain a better understanding of the high resolution data sets they work with on a daily basis. Isosurface timings (512{sup 3} grid): VTK 7.7 s, Parallel VTK (48-core) 1.3 s, PISTON OpenMP (48-core) 0.2 s, PISTON CUDA (Quadro 6000) 0.1 s.

  7. Validation of 3D surface reconstruction of vertebrae and spinal column using 3D ultrasound data--a pilot study.

    PubMed

    Nguyen, Duc V; Vo, Quang N; Le, Lawrence H; Lou, Edmond H M

    2015-02-01

    Adolescent idiopathic scoliosis (AIS) is a three-dimensional deformity of spine associated with vertebra rotation. The Cobb angle and axial vertebral rotation are important parameters to assess the severity of scoliosis. However, the vertebral rotation is seldom measured from radiographs due to time consuming. Different techniques have been developed to extract 3D spinal information. Among many techniques, ultrasound imaging is a promising method. This pilot study reported an image processing method to reconstruct the posterior surface of vertebrae from 3D ultrasound data. Three cadaver vertebrae, a Sawbones spine phantom, and a spine from a child with AIS were used to validate the development. The in-vitro result showed the surface of the reconstructed image was visually similar to the original objects. The dimension measurement error was <5 mm and the Pearson correlation was >0.99. The results also showed a high accuracy in vertebral rotation with errors of 0.8 ± 0.3°, 2.8 ± 0.3° and 3.6 ± 0.5° for the rotation values of 0°, 15° and 30°, respectively. Meanwhile, the difference in the Cobb angle between the phantom and the image was 4° and the vertebral rotation at the apex was 2°. The Cobb angle measured from the in-vivo ultrasound image was 4° different from the radiograph. PMID:25550193

  8. Accurate and efficient Nyström volume integral equation method for the Maxwell equations for multiple 3-D scatterers

    NASA Astrophysics Data System (ADS)

    Chen, Duan; Cai, Wei; Zinser, Brian; Cho, Min Hyung

    2016-09-01

    In this paper, we develop an accurate and efficient Nyström volume integral equation (VIE) method for the Maxwell equations for a large number of 3-D scatterers. The Cauchy Principal Values that arise from the VIE are computed accurately using a finite size exclusion volume together with explicit correction integrals consisting of removable singularities. Also, the hyper-singular integrals are computed using interpolated quadrature formulae with tensor-product quadrature nodes for cubes, spheres and cylinders, that are frequently encountered in the design of meta-materials. The resulting Nyström VIE method is shown to have high accuracy with a small number of collocation points and demonstrates p-convergence for computing the electromagnetic scattering of these objects. Numerical calculations of multiple scatterers of cubic, spherical, and cylindrical shapes validate the efficiency and accuracy of the proposed method.

  9. Fast, Accurate and Precise Mid-Sagittal Plane Location in 3D MR Images of the Brain

    NASA Astrophysics Data System (ADS)

    Bergo, Felipe P. G.; Falcão, Alexandre X.; Yasuda, Clarissa L.; Ruppert, Guilherme C. S.

    Extraction of the mid-sagittal plane (MSP) is a key step for brain image registration and asymmetry analysis. We present a fast MSP extraction method for 3D MR images, based on automatic segmentation of the brain and on heuristic maximization of the cerebro-spinal fluid within the MSP. The method is robust to severe anatomical asymmetries between the hemispheres, caused by surgical procedures and lesions. The method is also accurate with respect to MSP delineations done by a specialist. The method was evaluated on 64 MR images (36 pathological, 20 healthy, 8 synthetic), and it found a precise and accurate approximation of the MSP in all of them with a mean time of 60.0 seconds per image, mean angular variation within a same image (precision) of 1.26o and mean angular difference from specialist delineations (accuracy) of 1.64o.

  10. Surface classification and detection of latent fingerprints based on 3D surface texture parameters

    NASA Astrophysics Data System (ADS)

    Gruhn, Stefan; Fischer, Robert; Vielhauer, Claus

    2012-06-01

    In the field of latent fingerprint detection in crime scene forensics the classification of surfaces has importance. A new method for the scientific analysis of image based information for forensic science was investigated in the last years. Our image acquisition based on a sensor using Chromatic White Light (CWL) with a lateral resolution up to 2 μm. The used FRT-MicroProf 200 CWL 600 measurement device is able to capture high-resolution intensity and topography images in an optical and contact-less way. In prior work, we have suggested to use 2D surface texture parameters to classify various materials, which was a novel approach in the field of criminalistic forensic using knowledge from surface appearance and a chromatic white light sensor. A meaningful and useful classification of different crime scene specific surfaces is not existent. In this work, we want to extend such considerations by the usage of fourteen 3D surface parameters, called 'Birmingham 14'. In our experiment we define these surface texture parameters and use them to classify ten different materials in this test set-up and create specific material classes. Further it is shown in first experiments, that some surface texture parameters are sensitive to separate fingerprints from carrier surfaces. So far, the use of surface roughness is mainly known within the framework of material quality control. The analysis and classification of the captured 3D-topography images from crime scenes is important for the adaptive preprocessing depending on the surface texture. The adaptive preprocessing in dependency of surface classification is necessary for precise detection because of the wide variety of surface textures. We perform a preliminary study in usage of these 3D surface texture parameters as feature for the fingerprint detection. In combination with a reference sample we show that surface texture parameters can be an indication for a fingerprint and can be a feature in latent fingerprint detection.

  11. Mapping gray-scale image to 3D surface scanning data by ray tracing

    NASA Astrophysics Data System (ADS)

    Li, Peng; Jones, Peter R. M.

    1997-03-01

    The extraction and location of feature points from range imaging is an important but difficult task in machine vision based measurement systems. There exist some feature points which are not able to be detected from pure geometric characteristics, particularly in those measurement tasks related to the human body. The Loughborough Anthropometric Shadow Scanner (LASS) is a whole body surface scanner based on structured light technique. Certain applications of LASS require accurate location of anthropometric landmarks from the scanned data. This is sometimes impossible from existing raw data because some landmarks do not appear in the scanned data. Identification of these landmarks has to resort to surface texture of the scanned object. Modifications to LASS were made to allow gray-scale images to be captured before or after the object was scanned. Two-dimensional gray-scale image must be mapped to the scanned data to acquire the 3D coordinates of a landmark. The method to map 2D images to the scanned data is based on the colinearity conditions and ray-tracing method. If the camera center and image coordinates are known, the corresponding object point must lie on a ray starting from the camera center and connecting to the image coordinate. By intersecting the ray with the scanned surface of the object, the 3D coordinates of a point can be solved. Experimentation has demonstrated the feasibility of the method.

  12. Effects of 3D Toroidally Asymmetric Magnetic Field on Tokamak Magnetic Surfaces

    NASA Astrophysics Data System (ADS)

    Lao, L. L.

    2005-10-01

    The effects of 3D error magnetic field on magnetic surfaces are investigated using the DIII-D internal coils (I-Coils). Slowly rotating n=1 traveling waves at 5 Hz and various amplitudes were applied to systematically perturb the edge surfaces by programming the I-Coil currents. The vertical separatrix location difference between EFIT magnetic reconstructions that assumes toroidal symmetry and Thomson scattering Te measurements responds in phase to the applied perturbed field. The oscillation amplitudes increase with the strength of the applied field but are much smaller than those expected from the applied field alone. The results indicate that plasma response is important. Various plasma response models based on results from the MHD codes MARS and GATO are being developed and compared to the experimental observations. To more accurately evaluate the effects of magnetic measurement errors, a new form of the magnetic uncertainty matrix is also being implemented into EFIT. Details will be presented.

  13. Evaluation of 3D surface scanners for skin documentation in forensic medicine: comparison of benchmark surfaces

    PubMed Central

    Schweitzer, Wolf; Häusler, Martin; Bär, Walter; Schaepman, Michael

    2007-01-01

    Background Two 3D surface scanners using collimated light patterns were evaluated in a new application domain: to document details of surfaces similar to the ones encountered in forensic skin pathology. Since these scanners have not been specifically designed for forensic skin pathology, we tested their performance under practical constraints in an application domain that is to be considered new. Methods Two solid benchmark objects containing relevant features were used to compare two 3D surface scanners: the ATOS-II (GOM, Germany) and the QTSculptor (Polygon Technology, Germany). Both scanners were used to capture and process data within a limited amount of time, whereas point-and-click editing was not allowed. We conducted (a) a qualitative appreciation of setup, handling and resulting 3D data, (b) an experimental subjective evaluation of matching 3D data versus photos of benchmark object regions by a number of 12 judges who were forced to state their preference for either of the two scanners, and (c) a quantitative characterization of both 3D data sets comparing 220 single surface areas with the real benchmark objects in order to determine the recognition rate's possible dependency on feature size and geometry. Results The QTSculptor generated significantly better 3D data in both qualitative tests (a, b) that we had conducted, possibly because of a higher lateral point resolution; statistical evaluation (c) showed that the QTSculptor-generated data allowed the discrimination of features as little as 0.3 mm, whereas ATOS-II-generated data allowed for discrimination of features sized not smaller than 1.2 mm. Conclusion It is particularly important to conduct specific benchmark tests if devices are brought into new application domains they were not specifically designed for; using a realistic test featuring forensic skin pathology features, QT Sculptor-generated data quantitatively exceeded manufacturer's specifications, whereas ATOS-II-generated data was within

  14. APPROXIMATION OF SURFACES IN QUANTITATIVE 3-D RECONSTRUCTIONS

    EPA Science Inventory

    In serial section reconstructions a series of planar profiles are taken representing curves on the surface of the structure to be reconstructed. or a number of quantitative serial section methods, approximation of a surface is done by the formation of tiles between points of adja...

  15. Visual Short-Term Memory Benefit for Objects on Different 3-D Surfaces

    ERIC Educational Resources Information Center

    Xu, Yaoda; Nakayama, Ken

    2007-01-01

    Visual short-term memory (VSTM) plays an important role in visual cognition. Although objects are located on different 3-dimensional (3-D) surfaces in the real world, how VSTM capacity may be influenced by the presence of multiple 3-D surfaces has never been examined. By manipulating binocular disparities of visual displays, the authors found that…

  16. Simulation of light transport in scintillators based on 3D characterization of crystal surfaces

    PubMed Central

    Cherry, Simon R.

    2013-01-01

    In the development of positron emission tomography (PET) detectors, understanding and optimizing scintillator light collection is critical for achieving high performance, particularly when the design incorporates depth-of-interaction (DOI) encoding or time-of-flight information. Monte-Carlo simulations play an important role in guiding research in detector designs and popular software such as GATE now include models of light transport in scintillators. Although current simulation toolkits are able to provide accurate models of perfectly polished surfaces, they do not successfully predict light output for other surface finishes, for example those often used in DOI-encoding detectors. The lack of accuracy of those models mainly originates from a simplified description of rough surfaces as an ensemble of micro-facets determined by the distribution of their normal, typically a Gaussian distribution. The user can specify the standard deviation of this distribution, but this parameter does not provide a full description of the surface reflectance properties. We propose a different approach based on 3D measurements of the surface using atomic force microscopy (AFM). Polished and rough (unpolished) crystals were scanned to compute the surface reflectance properties. The angular distributions of reflectance and reflected rays were computed and stored in look-up tables (LUTs). The LUTs account for the effect of incidence angle and were integrated in a light transport model. Crystals of different sizes were simulated with and without reflector. The simulated maximum light output and the light output as a function of DOI showed very good agreement with experimental characterization of the crystals, indicating that our approach provides an accurate model of polished and rough surfaces and could be used to predict light collection in scintillators. This model is based on a true 3D representation of the surface, makes no assumption about the surface and provides insight on the

  17. Emergent surface superconductivity in a 3D topological insulator

    NASA Astrophysics Data System (ADS)

    Krusin-Elbaum, Lia

    Surfaces of three-dimensional topological insulators have emerged as one of the most remarkable states of condensed quantum matter where exotic charge and spin phases of Dirac particles could form. This work reports on novel mesoscopic superconductivity in the topological insulator Sb2Te3 with transition to zero resistance induced through a minor tuning of growth chemistry that depletes bulk conduction channels. The depletion shifts Fermi energy towards the Dirac point as witnessed by a factor of 300 reduction of bulk carrier density and by the largest carrier mobility (>25, 000 cm2V-1s-1) found in any topological material of this class. Direct evidence from transport, the unprecedentedly large diamagnetic screening, and the presence of ~ 25 meV gaps detected by scanning tunneling spectroscopy reveal the superconducting condensate to emerge first in surface puddles at unexpectedly high temperature of ~ 50 K, with the onset of global phase coherence at ~ 9 K. The unconventional spin response of Sb2Te3 and the presence of subsurface 2DEG quantum well states arising from charge transfer to the surface are likely to play a role in the emergent superconducting state. The rich structure of this state lends itself to manipulation via growth conditions and the material parameters such as Fermi velocity and mean free path. This work was supported by NSF DMR-1122594, DMR-1420634, DMR-1322483, and DOD-W911NF-13-1-0159.

  18. Fast and accurate global multiphase arrival tracking: the irregular shortest-path method in a 3-D spherical earth model

    NASA Astrophysics Data System (ADS)

    Huang, Guo-Jiao; Bai, Chao-Ying; Greenhalgh, Stewart

    2013-09-01

    The traditional grid/cell-based wavefront expansion algorithms, such as the shortest path algorithm, can only find the first arrivals or multiply reflected (or mode converted) waves transmitted from subsurface interfaces, but cannot calculate the other later reflections/conversions having a minimax time path. In order to overcome the above limitations, we introduce the concept of a stationary minimax time path of Fermat's Principle into the multistage irregular shortest path method. Here we extend it from Cartesian coordinates for a flat earth model to global ray tracing of multiple phases in a 3-D complex spherical earth model. The ray tracing results for 49 different kinds of crustal, mantle and core phases show that the maximum absolute traveltime error is less than 0.12 s and the average absolute traveltime error is within 0.09 s when compared with the AK135 theoretical traveltime tables for a 1-D reference model. Numerical tests in terms of computational accuracy and CPU time consumption indicate that the new scheme is an accurate, efficient and a practical way to perform 3-D multiphase arrival tracking in regional or global traveltime tomography.

  19. Superhydrophobic PDMS surfaces with three-dimensional (3D) pattern-dependent controllable adhesion

    NASA Astrophysics Data System (ADS)

    Yong, Jiale; Yang, Qing; Chen, Feng; Zhang, Dongshi; Du, Guangqing; Bian, Hao; Si, Jinhai; Yun, Feng; Hou, Xun

    2014-01-01

    In this paper, we demonstrate an effective approach for the three-dimensional (3D) pattern-structured superhydrophobic PDMS surfaces with controllable adhesion by using femtosecond laser etching method. By combining different laser power with a multi-layered etching way, various 3D patterns can be fabricated (for example, convex triangle array, round pit array, cylindrical array, convex rhombus array and concave triangle-cone array). The as-prepared surfaces with 3D patterns show superhydrophobic character and water controllable adhesion that range from ultralow to ultrahigh by designing different 3D patterns, on which the sliding angle can be controlled from 1° to 90° (the water droplet is firmly pinned on the superhydrophobic surface without any movement at any tilted angles). The 3D pattern-dependent adhesive property is attributed to the different contact modes. This work will provide a facile and promising strategy for the adhesion adjustment on superhydrophobic surfaces.

  20. Focus Variation - A New Technology for High Resolution Optical 3D Surface Metrology

    NASA Astrophysics Data System (ADS)

    Scherer, S.

    2009-04-01

    roughness measurements. The 3D measurement device simultaneously captures the entire surface topographic information in combination with its true color information. Both the topographic and color information are registered to the 3D data file. The system is capable to handle a large amount of data and can be used for industrial quality assurance as well as research and development activities. The key applications of the system are: - Surface analysis - Characterization of tools (particularly crucial parameters such as radii and angles) and all kinds of scientific materials - Failure analysis - Investigation of corrosion and tribology (cause, influence, effects) - Variance and wear analysis Compared to tactile instruments, the technique of Focus-Variation offers several advantages from which the performance of the geo-instruments benefits. Since the optical technique is an area-based one, a much larger amount of data is obtained from a single measurement, leading to more accurate results. Also, measurements are non destructive and wearless.

  1. Optimizing fabrication of electrodeposited 3D surface features

    SciTech Connect

    Steffani, C., LLNL

    1998-07-01

    Selective electrodeposition onto specially masked surfaces (producing blind holes with non-conductive side walls) has been investigated. The thick masks are low cost polymer sheet into which holes and other patterns are machined. Plating with this type of masking system is one method of fabricating medium aspect ratio metallic structures (structures whose width to length ratio is greater than 10/1). The experiment was conducted with deposits of OFC copper from an acid sulfate solution, but similar results are expected with other metals. Structure diameter varied from 0.25 mm to 3.8 mm (0.01`` to 0.150``). The effect of current density, electrolyte concentration, solution temperature, and agitation on deposition rate were investigated. Deposit quality, deposition rate, and optimal plating parameters were evaluated.

  2. Combination of 3D skin surface texture features and 2D ABCD features for improved melanoma diagnosis.

    PubMed

    Ding, Yi; John, Nigel W; Smith, Lyndon; Sun, Jiuai; Smith, Melvyn

    2015-10-01

    Two-dimensional asymmetry, border irregularity, colour variegation and diameter (ABCD) features are important indicators currently used for computer-assisted diagnosis of malignant melanoma (MM); however, they often prove to be insufficient to make a convincing diagnosis. Previous work has demonstrated that 3D skin surface normal features in the form of tilt and slant pattern disruptions are promising new features independent from the existing 2D ABCD features. This work investigates that whether improved lesion classification can be achieved by combining the 3D features with the 2D ABCD features. Experiments using a nonlinear support vector machine classifier show that many combinations of the 2D ABCD features and the 3D features can give substantially better classification accuracy than using (1) single features and (2) many combinations of the 2D ABCD features. The best 2D and 3D feature combination includes the overall 3D skin surface disruption, the asymmetry and all the three colour channel features. It gives an overall 87.8 % successful classification, which is better than the best single feature with 78.0 % and the best 2D feature combination with 83.1 %. These demonstrate that (1) the 3D features have additive values to improve the existing lesion classification and (2) combining the 3D feature with all the 2D features does not lead to the best lesion classification. The two ABCD features not selected by the best 2D and 3D combination, namely (1) the border feature and (2) the diameter feature, were also studied in separate experiments. It found that inclusion of either feature in the 2D and 3D combination can successfully classify 3 out of 4 lesion groups. The only one group not accurately classified by either feature can be classified satisfactorily by the other. In both cases, they have shown better classification performances than those without the 3D feature in the combinations. This further demonstrates that (1) the 3D feature can be used to

  3. Performance assessment of 3D surface imaging technique for medical imaging applications

    NASA Astrophysics Data System (ADS)

    Li, Tuotuo; Geng, Jason; Li, Shidong

    2013-03-01

    Recent development in optical 3D surface imaging technologies provide better ways to digitalize the 3D surface and its motion in real-time. The non-invasive 3D surface imaging approach has great potential for many medical imaging applications, such as motion monitoring of radiotherapy, pre/post evaluation of plastic surgery and dermatology, to name a few. Various commercial 3D surface imaging systems have appeared on the market with different dimension, speed and accuracy. For clinical applications, the accuracy, reproducibility and robustness across the widely heterogeneous skin color, tone, texture, shape properties, and ambient lighting is very crucial. Till now, a systematic approach for evaluating the performance of different 3D surface imaging systems still yet exist. In this paper, we present a systematic performance assessment approach to 3D surface imaging system assessment for medical applications. We use this assessment approach to exam a new real-time surface imaging system we developed, dubbed "Neo3D Camera", for image-guided radiotherapy (IGRT). The assessments include accuracy, field of view, coverage, repeatability, speed and sensitivity to environment, texture and color.

  4. Visualization of 3D elbow kinematics using reconstructed bony surfaces

    NASA Astrophysics Data System (ADS)

    Lalone, Emily A.; McDonald, Colin P.; Ferreira, Louis M.; Peters, Terry M.; King, Graham J. W.; Johnson, James A.

    2010-02-01

    An approach for direct visualization of continuous three-dimensional elbow kinematics using reconstructed surfaces has been developed. Simulation of valgus motion was achieved in five cadaveric specimens using an upper arm simulator. Direct visualization of the motion of the ulna and humerus at the ulnohumeral joint was obtained using a contact based registration technique. Employing fiducial markers, the rendered humerus and ulna were positioned according to the simulated motion. The specific aim of this study was to investigate the effect of radial head arthroplasty on restoring elbow joint stability after radial head excision. The position of the ulna and humerus was visualized for the intact elbow and following radial head excision and replacement. Visualization of the registered humerus/ulna indicated an increase in valgus angulation of the ulna with respect to the humerus after radial head excision. This increase in valgus angulation was restored to that of an elbow with a native radial head following radial head arthroplasty. These findings were consistent with previous studies investigating elbow joint stability following radial head excision and arthroplasty. The current technique was able to visualize a change in ulnar position in a single DoF. Using this approach, the coupled motion of ulna undergoing motion in all 6 degrees-of-freedom can also be visualized.

  5. 3-D micro surface profilometry employing novel Mirau-based lateral scanning interferometry

    NASA Astrophysics Data System (ADS)

    Chen, Liang-Chia; Le, Manh-Trung; Lin, Yi-Shiuan

    2014-09-01

    An innovative 3-D surface imaging methodology for reconstructing micro surface profiles with a long depth measuring range and a nano-scale resolution was developed using the newly developed Mirau-based lateral scanning interferometry (LSI). The current measuring field of view (FOV) of conventional white light interferometers is limited by microscopic views of the existing interferometric objectives, such as those in Michelson, Mirau or Linnik designs. Moreover, the vertical scanning operation required for acquiring volumetric interferometric data is extremely time-consuming and makes white light vertical scanning interferometry (VSI) infeasible for automatic optical inspection (AOI) of micro 3-D structures. To resolve this, a newly developed white light LSI method based on Mirau’s optical configuration was developed by controlling the tilting angle of the reference mirror in the Mirau interferometric objective. With the proposed optical configuration, the surface is inspected at a tilting angle with respect to the maximum coherence plane of the interferometric system along its lateral scanning direction when the objective lies perpendicular to the tested surface. In addition, a system calibration method was developed to establish an accurate mathematical mapping model between the object depth and the lateral axis. To evaluate the feasibility of the methodology, a calibrated step height was measured for evaluating the accuracy and repeatability. Some industrial samples, such as photon spacers and other microstructures fabricated by nano-imprinting processes, were measured to verify the actual performance on real components. It was found that the measurement repeatability was controlled less than 60 nm within one standard deviation for a maximum measurable depth of 27.21 µm.

  6. Cell Proliferation on Macro/Nano Surface Structure and Collagen Immobilization of 3D Polycaprolactone Scaffolds.

    PubMed

    Park, Young-Ouk; Myung, Sung-Woon; Kook, Min-Suk; Jung, Sang-Chul; Kim, Byung-Hoon

    2016-02-01

    In this study, 3D polycaprolactone (PCL) scaffolds were fabricated by 3D printing technique. The macro/nano morphology of, 3D PCL scaffolds surface was etched with oxygen plasma. Acrylic acid (AA) plasma-polymerization was performed to functionalize the macro/nano surface with carboxyl groups and then collagen was immobilized with plasma-polymerized 3D PCL scaffolds. After O2 plasma and AA plasma-polymerization, contact angles were decreased. The FE-SEM and AFM results showed that O2 plasma is increased the surface roughness. The MTT assay results showed that proliferation of the M3CT3-E1 cells increased on the oxygen plasma treated and collagen immobilized 3D PCL scaffolds. PMID:27433597

  7. Surface-to-surface scattering in three-dimensional (3D) topological insulator (TI) thin films

    NASA Astrophysics Data System (ADS)

    Yin, Gen; Wickramaratne, Darshana; Lake, Roger

    2013-03-01

    When the thickness of a 3D TI material is reduced below approximately 6nm, hybridization of the opposite surfaces states can result in inter-surface tunneling. Due to the rotational symmetry of the thin film, the k-s locking relation on opposite surfaces also has opposite chirality. Thus, in this inter-surface scattering mechanism, back-scattering is allowed without the flip of the spin. This effect breaks the protection of TI surface states against back-scattering. To investigate the influence of the inter-surface scattering mechanism, we study different near-elastic scattering mechanisms in the surface state transport using Boltzmann transport equations within the relaxation time approximation. The effect of screened Coulomb impurities, low-energy acoustic phonons and surface magnetic impurities on the TI surface states will be discussed. The response of the inter-surface scattering of TI states to various external stimuli such as a Rashba-like splitting and the orientation of the impurity magnetic moments will also be presented. Using our simulation results, we propose possible experimental methods to modulate the back-scatter protection of TI surface states in thin film TI materials.

  8. Accurate quantification of local changes for carotid arteries in 3D ultrasound images using convex optimization-based deformable registration

    NASA Astrophysics Data System (ADS)

    Cheng, Jieyu; Qiu, Wu; Yuan, Jing; Fenster, Aaron; Chiu, Bernard

    2016-03-01

    Registration of longitudinally acquired 3D ultrasound (US) images plays an important role in monitoring and quantifying progression/regression of carotid atherosclerosis. We introduce an image-based non-rigid registration algorithm to align the baseline 3D carotid US with longitudinal images acquired over several follow-up time points. This algorithm minimizes the sum of absolute intensity differences (SAD) under a variational optical-flow perspective within a multi-scale optimization framework to capture local and global deformations. Outer wall and lumen were segmented manually on each image, and the performance of the registration algorithm was quantified by Dice similarity coefficient (DSC) and mean absolute distance (MAD) of the outer wall and lumen surfaces after registration. In this study, images for 5 subjects were registered initially by rigid registration, followed by the proposed algorithm. Mean DSC generated by the proposed algorithm was 79:3+/-3:8% for lumen and 85:9+/-4:0% for outer wall, compared to 73:9+/-3:4% and 84:7+/-3:2% generated by rigid registration. Mean MAD of 0:46+/-0:08mm and 0:52+/-0:13mm were generated for lumen and outer wall respectively by the proposed algorithm, compared to 0:55+/-0:08mm and 0:54+/-0:11mm generated by rigid registration. The mean registration time of our method per image pair was 143+/-23s.

  9. Segmentation, surface rendering, and surface simplification of 3-D skull images for the repair of a large skull defect

    NASA Astrophysics Data System (ADS)

    Wan, Weibing; Shi, Pengfei; Li, Shuguang

    2009-10-01

    Given the potential demonstrated by research into bone-tissue engineering, the use of medical image data for the rapid prototyping (RP) of scaffolds is a subject worthy of research. Computer-aided design and manufacture and medical imaging have created new possibilities for RP. Accurate and efficient design and fabrication of anatomic models is critical to these applications. We explore the application of RP computational methods to the repair of a pediatric skull defect. The focus of this study is the segmentation of the defect region seen in computerized tomography (CT) slice images of this patient's skull and the three-dimensional (3-D) surface rendering of the patient's CT-scan data. We see if our segmentation and surface rendering software can improve the generation of an implant model to fill a skull defect.

  10. Enhancing surface interactions with colon cancer cells on a transferrin-conjugated 3D nanostructured substrate.

    PubMed

    Banerjee, Shashwat S; Paul, Debjani; Bhansali, Sujit G; Aher, Naval D; Jalota-Badhwar, Archana; Khandare, Jayant

    2012-06-11

    A transferrin-conjugated PEG-Fe(3) O(4) nanostructured matrix is developed to explore cellular responses in terms of enhanced cell adhesion, specific interactions between ligands in the matrix and molecular receptors on the cell membrane, comparison of cell shapes on 2D and 3D surfaces, and effect of polymer architecture on cell adhesion. Integration of such advanced synthetic nanomaterials into a functionalized 3D matrix to control cell behavior on surfaces will have implications in nanomedicine. PMID:22434693

  11. Characterisation of the surface structure of 3D printed scaffolds for cell infiltration and surgical suturing.

    PubMed

    Ruiz-Cantu, Laura; Gleadall, Andrew; Faris, Callum; Segal, Joel; Shakesheff, Kevin; Yang, Jing

    2016-03-01

    3D printing is of great interest for tissue engineering scaffolds due to the ability to form complex geometries and control internal structures, including porosity and pore size. The porous structure of scaffolds plays an important role in cell ingrowth and nutrition infusion. Although the internal porosity and pore size of 3D printed scaffolds have been frequently studied, the surface porosity and pore size, which are critical for cell infiltration and mass transport, have not been investigated. The surface geometry can differ considerably from the internal scaffold structure depending on the 3D printing process. It is vital to be able to control the surface geometry of scaffolds as well as the internal structure to fabricate optimal architectures. This work presents a method to control the surface porosity and pore size of 3D printed scaffolds. Six scaffold designs have been printed with surface porosities ranging from 3% to 21%. We have characterised the overall scaffold porosity and surface porosity using optical microscopy and microCT. It has been found that surface porosity has a significant impact on cell infiltration and proliferation. In addition, the porosity of the surface has been found to have an effect on mechanical properties and on the forces required to penetrate the scaffold with a surgical suturing needle. To the authors' knowledge, this study is the first to investigate the surface geometry of extrusion-based 3D printed scaffolds and demonstrates the importance of surface geometry in cell infiltration and clinical manipulation. PMID:26930179

  12. 3D Simulation of Missing Pellet Surface Defects in Light Water Reactor Fuel Rods

    SciTech Connect

    B.W. Spencer; J.D. Hales; S.R. Novascone; R.L. Williamson

    2012-09-01

    The cladding on light water reactor (LWR) fuel rods provides a stable enclosure for fuel pellets and serves as a first barrier against fission product release. Consequently, it is important to design fuel to prevent cladding failure due to mechanical interactions with fuel pellets. Cladding stresses can be effectively limited by controlling power increase rates. However, it has been shown that local geometric irregularities caused by manufacturing defects known as missing pellet surfaces (MPS) in fuel pellets can lead to elevated cladding stresses that are sufficiently high to cause cladding failure. Accurate modeling of these defects can help prevent these types of failures. Nuclear fuel performance codes commonly use a 1.5D (axisymmetric, axially-stacked, one-dimensional radial) or 2D axisymmetric representation of the fuel rod. To study the effects of MPS defects, results from 1.5D or 2D fuel performance analyses are typically mapped to thermo-mechanical models that consist of a 2D plane-strain slice or a full 3D representation of the geometry of the pellet and clad in the region of the defect. The BISON fuel performance code developed at Idaho National Laboratory employs either a 2D axisymmetric or 3D representation of the full fuel rod. This allows for a computational model of the full fuel rod to include local defects. A 3D thermo-mechanical model is used to simulate the global fuel rod behavior, and includes effects on the thermal and mechanical behavior of the fuel due to accumulation of fission products, fission gas production and release, and the effects of fission gas accumulation on thermal conductivity across the fuel-clad gap. Local defects can be modeled simply by including them in the 3D fuel rod model, without the need for mapping between two separate models. This allows for the complete set of physics used in a fuel performance analysis to be included naturally in the computational representation of the local defect, and for the effects of the

  13. Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer

    SciTech Connect

    Djajaputra, David; Li Shidong

    2005-01-01

    We describe an approach for external beam radiotherapy of breast cancer that utilizes the three-dimensional (3D) surface information of the breast. The surface data of the breast are obtained from a 3D optical camera that is rigidly mounted on the ceiling of the treatment vault. This 3D camera utilizes light in the visible range therefore it introduces no ionization radiation to the patient. In addition to the surface topographical information of the treated area, the camera also captures gray-scale information that is overlaid on the 3D surface image. This allows us to visualize the skin markers and automatically determine the isocenter position and the beam angles in the breast tangential fields. The field sizes and shapes of the tangential, supraclavicular, and internal mammary gland fields can all be determined according to the 3D surface image of the target. A least-squares method is first introduced for the tangential-field setup that is useful for compensation of the target shape changes. The entire process of capturing the 3D surface data and subsequent calculation of beam parameters typically requires less than 1 min. Our tests on phantom experiments and patient images have achieved the accuracy of 1 mm in shift and 0.5 deg. in rotation. Importantly, the target shape and position changes in each treatment session can both be corrected through this real-time image-guided system.

  14. ALPINE3D: a detailed model of mountain surface processes and its application to snow hydrology

    NASA Astrophysics Data System (ADS)

    Lehning, Michael; Völksch, Ingo; Gustafsson, David; Nguyen, Tuan Anh; Stähli, Manfred; Zappa, Massimiliano

    2006-06-01

    Current models of snow cover distribution, soil moisture, surface runoff and river discharge typically have very simple parameterizations of surface processes, such as degree-day factors or single-layer snow cover representation. For the purpose of reproducing catchment runoff, simple snowmelt routines have proven to be accurate, provided that they are carefully calibrated specifically for the catchment they are applied to. The use of more detailed models is, however, useful to understand and quantify the role of individual surface processes for catchment hydrology, snow cover status and soil moisture distribution.We introduce ALPINE3D, a model for the high-resolution simulation of alpine surface processes, in particular snow processes. The model can be driven by measurements from automatic weather stations or by meteorological model outputs. As a preprocessing alternative, specific high-resolution meteorological fields can be created by running a meteorological model. The core three-dimensional ALPINE3D modules consist of a radiation balance model (which uses a view-factor approach and includes shortwave scattering and longwave emission from terrain and tall vegetation) and a drifting snow model solving a diffusion equation for suspended snow and a saltation transport equation. The processes in the atmosphere are thus treated in three dimensions and are coupled to a distributed (in the hydrological sense of having a spatial representation of the catchment properties) one-dimensional model of vegetation, snow and soil (SNOWPACK) using the assumption that lateral exchange is small in these media. The model is completed by a conceptual runoff module. The model can be run with a choice of modules, thus generating more or less detailed surface forcing data as input for runoff generation simulations. The model modules can be run in a parallel (distributed) mode using a GRID infrastructure to allow computationally demanding tasks. In a case study from the Dischma Valley

  15. UAV based 3D digital surface model to estimate paleolandscape in high mountainous environment

    NASA Astrophysics Data System (ADS)

    Mészáros, János; Árvai, Mátyás; Kohán, Balázs; Deák, Márton; Nagy, Balázs

    2016-04-01

    Our method to present current state of a peat bog was focused on the possible use of a UAV-system and later Structure-from-motion algorithms as processing technique. The peat bog site is located on the Vinderel Plateau, Farcǎu Massif, Maramures Mountains (Romania). The peat bog (1530 m a.s.l., N47°54'11", E24°26'37") lies below Rugasu ridge (c. 1820 m a.s.l.) and the locality serves as a conservation area for fallen down coniferous trees. Peat deposits were formed in a landslide concavity on the western slope of Farcǎu Massif. Nowadays the site is surrounded by a completely deforested landscape, and Farcǎu Massif lies above the depressed treeline. The peat bog has an extraordinary geomorphological situation, because a gully reached the bog and drained the water. In the recent past sedimentological and dendrochronological researches have been initiated. However, an accurate 3D digital surface model also needed for a complex paleoenvironmental research. Last autumn the bog and its surroundings were finally surveyed by a multirotor UAV developed in-house based on an open-source flight management unit and its firmware. During this survey a lightweight action camera (mainly to decrease payload weight) was used to take aerial photographs. While our quadcopter is capable to fly automatically on a predefined flight route, several over- and sidelapping flight lines were generated prior to the actual survey on the ground using a control software running on a notebook. Despite those precautions, limited number of batteries and severe weather affected our final flights, resulting a reduced surveyed area around peat bog. Later, during the processing we looked for a reliable tool which powerful enough to process more than 500 photos taken during flights. After testing several software Agisoft PhotoScan was used to create 3D point cloud and mesh about bog and its environment. Due to large number of photographs PhotoScan had to be configured for network processing to get

  16. Euro-Maps 3D- A Transnational, High-Resolution Digital Surface Model For Europe

    NASA Astrophysics Data System (ADS)

    Uttenthaler, A.; Barner, F.; Hass, T.; Makiola, J.; d'Angelo, P.; Reinartz, P.; Carl, S.; Steiner, K.

    2013-12-01

    Euro-Maps 3D is a homogeneous 5 m spaced digital surface model (DSM) semi-automatically derived by Euromap from 2.5 m in-flight stereo data provided by the Indian IRS-P5 Cartosat-1 satellite. This new and innovative product has been developed in close co- operation with the Remote Sensing Technology Institute (IMF) of the German Aerospace Center (DLR) and is being jointly exploited. The very detailed and accurate representation of the surface is achieved by using a sophisticated and well adapted algorithm implemented on the basis of the Semi-Global Matching approach. In addition, the final product includes detailed flanking information consisting of several pixel-based quality and traceability layers also including an ortho layer. The product is believed to provide maximum accuracy and transparency. The DSM product meets and exceeds HRE80 qualification standards. The DSM product will be made available transnational in a homogeneous quality for most parts of Europe, North Africa and Turkey by Euromap step-by-step. Other areas around the world are processed on demand.

  17. Fish body surface data measurement based on 3D digital image correlation

    NASA Astrophysics Data System (ADS)

    Jiang, Ming; Qian, Chen; Yang, Wenkai

    2016-01-01

    To film the moving fish in the glass tank, light will be bent at the interface of air and glass, glass and water. Based on binocular stereo vision and refraction principle, we establish a mathematical model of 3D image correlation to reconstruct the 3D coordinates of samples in the water. Marking speckle in fish surface, a series of real-time speckle images of swimming fish will be obtained by two high-speed cameras, and instantaneous 3D shape, strain, displacement etc. of fish will be reconstructed.

  18. Simplified generation of biomedical 3D surface model data for embedding into 3D portable document format (PDF) files for publication and education.

    PubMed

    Newe, Axel; Ganslandt, Thomas

    2013-01-01

    The usefulness of the 3D Portable Document Format (PDF) for clinical, educational, and research purposes has recently been shown. However, the lack of a simple tool for converting biomedical data into the model data in the necessary Universal 3D (U3D) file format is a drawback for the broad acceptance of this new technology. A new module for the image processing and rapid prototyping framework MeVisLab does not only provide a platform-independent possibility to create surface meshes out of biomedical/DICOM and other data and to export them into U3D--it also lets the user add meta data to these meshes to predefine colors and names that can be processed by a PDF authoring software while generating 3D PDF files. Furthermore, the source code of the respective module is available and well documented so that it can easily be modified for own purposes. PMID:24260144

  19. Simplified Generation of Biomedical 3D Surface Model Data for Embedding into 3D Portable Document Format (PDF) Files for Publication and Education

    PubMed Central

    Newe, Axel; Ganslandt, Thomas

    2013-01-01

    The usefulness of the 3D Portable Document Format (PDF) for clinical, educational, and research purposes has recently been shown. However, the lack of a simple tool for converting biomedical data into the model data in the necessary Universal 3D (U3D) file format is a drawback for the broad acceptance of this new technology. A new module for the image processing and rapid prototyping framework MeVisLab does not only provide a platform-independent possibility to create surface meshes out of biomedical/DICOM and other data and to export them into U3D – it also lets the user add meta data to these meshes to predefine colors and names that can be processed by a PDF authoring software while generating 3D PDF files. Furthermore, the source code of the respective module is available and well documented so that it can easily be modified for own purposes. PMID:24260144

  20. Land surface temperature from INSAT-3D imager data: Retrieval and assimilation in NWP model

    NASA Astrophysics Data System (ADS)

    Singh, Randhir; Singh, Charu; Ojha, Satya P.; Kumar, A. Senthil; Kishtawal, C. M.; Kumar, A. S. Kiran

    2016-06-01

    A new algorithm is developed for retrieving the land surface temperature (LST) from the imager radiance observations on board geostationary operational Indian National Satellite (INSAT-3D). The algorithm is developed using the two thermal infrared channels (TIR1 10.3-11.3 µm and TIR2 11.5-12.5 µm) via genetic algorithm (GA). The transfer function that relates LST and thermal radiances is developed using radiative transfer model simulated database. The developed algorithm has been applied on the INSAT-3D observed radiances, and LST retrieved from the developed algorithm has been validated with Moderate Resolution Imaging Spectroradiometer land surface temperature (LST) product. The developed algorithm demonstrates a good accuracy, without significant bias and standard deviations of 1.78 K and 1.41 K during daytime and nighttime, respectively. The newly proposed algorithm performs better than the operational algorithm used for LST retrieval from INSAT-3D satellite. Further, a set of data assimilation experiments is conducted with the Weather Research and Forecasting (WRF) model to assess the impact of INSAT-3D LST on model forecast skill over the Indian region. The assimilation experiments demonstrated a positive impact of the assimilated INSAT-3D LST, particularly on the lower tropospheric temperature and moisture forecasts. The temperature and moisture forecast errors are reduced (as large as 8-10%) with the assimilation of INSAT-3D LST, when compared to forecasts that were obtained without the assimilation of INSAT-3D LST. Results of the additional experiments of comparative performance of two LST products, retrieved from operational and newly proposed algorithms, indicate that the impact of INSAT-3D LST retrieved using newly proposed algorithm is significantly larger compared to the impact of INSAT-3D LST retrieved using operational algorithm.

  1. Clinical evaluation of accommodation and ocular surface stability relavant to visual asthenopia with 3D displays

    PubMed Central

    2014-01-01

    Background To validate the association between accommodation and visual asthenopia by measuring objective accommodative amplitude with the Optical Quality Analysis System (OQAS®, Visiometrics, Terrassa, Spain), and to investigate associations among accommodation, ocular surface instability, and visual asthenopia while viewing 3D displays. Methods Fifteen normal adults without any ocular disease or surgical history watched the same 3D and 2D displays for 30 minutes. Accommodative ability, ocular protection index (OPI), and total ocular symptom scores were evaluated before and after viewing the 3D and 2D displays. Accommodative ability was evaluated by the near point of accommodation (NPA) and OQAS to ensure reliability. The OPI was calculated by dividing the tear breakup time (TBUT) by the interblink interval (IBI). The changes in accommodative ability, OPI, and total ocular symptom scores after viewing 3D and 2D displays were evaluated. Results Accommodative ability evaluated by NPA and OQAS, OPI, and total ocular symptom scores changed significantly after 3D viewing (p = 0.005, 0.003, 0.006, and 0.003, respectively), but yielded no difference after 2D viewing. The objective measurement by OQAS verified the decrease of accommodative ability while viewing 3D displays. The change of NPA, OPI, and total ocular symptom scores after 3D viewing had a significant correlation (p < 0.05), implying direct associations among these factors. Conclusions The decrease of accommodative ability after 3D viewing was validated by both subjective and objective methods in our study. Further, the deterioration of accommodative ability and ocular surface stability may be causative factors of visual asthenopia in individuals viewing 3D displays. PMID:24612686

  2. 3D surface reconstruction based on image stitching from gastric endoscopic video sequence

    NASA Astrophysics Data System (ADS)

    Duan, Mengyao; Xu, Rong; Ohya, Jun

    2013-09-01

    This paper proposes a method for reconstructing 3D detailed structures of internal organs such as gastric wall from endoscopic video sequences. The proposed method consists of the four major steps: Feature-point-based 3D reconstruction, 3D point cloud stitching, dense point cloud creation and Poisson surface reconstruction. Before the first step, we partition one video sequence into groups, where each group consists of two successive frames (image pairs), and each pair in each group contains one overlapping part, which is used as a stitching region. Fist, the 3D point cloud of each group is reconstructed by utilizing structure from motion (SFM). Secondly, a scheme based on SIFT features registers and stitches the obtained 3D point clouds, by estimating the transformation matrix of the overlapping part between different groups with high accuracy and efficiency. Thirdly, we select the most robust SIFT feature points as the seed points, and then obtain the dense point cloud from sparse point cloud via a depth testing method presented by Furukawa. Finally, by utilizing Poisson surface reconstruction, polygonal patches for the internal organs are obtained. Experimental results demonstrate that the proposed method achieves a high accuracy and efficiency for 3D reconstruction of gastric surface from an endoscopic video sequence.

  3. Constructing topologically connected surfaces for the comprehensive analysis of 3-D medical structures

    NASA Astrophysics Data System (ADS)

    Kalvin, Alan D.; Cutting, Court B.; Haddad, Betsy; Noz, Marilyn E.

    1991-06-01

    Three-dimensional (3D) medical imaging deals with the visualization, manipulation, and measuring of objects in 3D medical images. So far, research efforts have concentrated primarily on visualization, using well-developed methods from computer graphics. Very little has been achieved in developing techniques for manipulating medical objects, or for extracting quantitative measurements from them beyond volume calculation (by counting voxels), and computing distances and angles between manually located surface points. A major reason for the slow pace in the development of manipulation and quantification methods lies with the limitations of current algorithms for constructing surfaces from 3D solid objects. We show that current surface construction algorithms either (a) do not construct valid surface descriptions of solid objects or (b) produce surface representations that are not particularly suitable for anything other than visualization. We present ALLIGATOR, a new surface construction algorithm that produces valid, topologically connected surface representations of solid objects. We have developed a modeling system based on the surface representations created by ALLIGATOR that is suitable for developing algorithms to visualize, manipulate, and quantify 3D medical objects. Using this modeling system we have developed a method for efficiently computing principle curvatures and directions on surfaces. These measurements form the basis for a new metric system being developed for morphometrics. The modeling system is also being used in the development of systems for quantitative pre-surgical planning and surgical augmentation.

  4. Automated generation of NC part programs for excimer laser ablation micromachining from known 3D surfaces

    NASA Astrophysics Data System (ADS)

    Mutapcic, Emir; Iovenitti, Pio G.; Hayes, Jason P.

    2002-11-01

    The purpose of this research project is to improve the capability of the laser micromachinning process, so that any desired 3D surface can be produced by taking the 3D information from a CAD system and automatically generating the NC part programs. In addition, surface quality should be able to be controlled by specifying optimised parameters. This paper presents the algorithms and a software system, which processes 3D geometry in an STL file format from a CAD system and produces the NC part program to mill the surface using the Excimer laser ablation process. Simple structures are used to demonstrate the prototype system's part programming capabilities, and an actual surface is machined.

  5. Poly(acrylic acid) brushes pattern as a 3D functional biosensor surface for microchips

    NASA Astrophysics Data System (ADS)

    Wang, Yan-Mei; Cui, Yi; Cheng, Zhi-Qiang; Song, Lu-Sheng; Wang, Zhi-You; Han, Bao-Hang; Zhu, Jin-Song

    2013-02-01

    Poly(acrylic acid) (PAA) brushes, a novel three dimensional (3D) precursor layer of biosensor or protein microarrays, possess high protein loading level and low non-specific protein adsorption. In this article, we describe a simple and convenient way to fabricate 3D PAA brushes pattern by microcontact printing (μCP) and characterize it with FT-IR and optical microscopy. The carboxyl groups of PAA brushes can be applied to covalently immobilize protein for immunoassay. Thriving 3D space made by patterning PAA brushes thin film is available to enhance protein immobilization, which is confirmed by measuring model protein interaction between human immunoglobulin G (H-IgG) and goat anti-H-IgG (G-H-IgG) with fluorescence microscopy and surface plasmon resonance imaging (SPRi). As expected, the SPRi signals of H-IgG coating on 3D PAA brushes pattern and further measuring specific binding with G-H-IgG are all larger than that of 3D PAA brushes without pattern and 2D bare gold surface. We further revealed that this surface can be used for high-throughput screening and clinical diagnosis by label-free assaying of Hepatitis-B-Virus surface antibody (HBsAb) with Hepatitis-B-Virus surface antigen (HBsAg) concentration array chip. The linearity range for HBsAb assay is wider than that of conventional ELISA method.

  6. What's the Point of a Raster ? Advantages of 3D Point Cloud Processing over Raster Based Methods for Accurate Geomorphic Analysis of High Resolution Topography.

    NASA Astrophysics Data System (ADS)

    Lague, D.

    2014-12-01

    High Resolution Topographic (HRT) datasets are predominantly stored and analyzed as 2D raster grids of elevations (i.e., Digital Elevation Models). Raster grid processing is common in GIS software and benefits from a large library of fast algorithms dedicated to geometrical analysis, drainage network computation and topographic change measurement. Yet, all instruments or methods currently generating HRT datasets (e.g., ALS, TLS, SFM, stereo satellite imagery) output natively 3D unstructured point clouds that are (i) non-regularly sampled, (ii) incomplete (e.g., submerged parts of river channels are rarely measured), and (iii) include 3D elements (e.g., vegetation, vertical features such as river banks or cliffs) that cannot be accurately described in a DEM. Interpolating the raw point cloud onto a 2D grid generally results in a loss of position accuracy, spatial resolution and in more or less controlled interpolation. Here I demonstrate how studying earth surface topography and processes directly on native 3D point cloud datasets offers several advantages over raster based methods: point cloud methods preserve the accuracy of the original data, can better handle the evaluation of uncertainty associated to topographic change measurements and are more suitable to study vegetation characteristics and steep features of the landscape. In this presentation, I will illustrate and compare Point Cloud based and Raster based workflows with various examples involving ALS, TLS and SFM for the analysis of bank erosion processes in bedrock and alluvial rivers, rockfall statistics (including rockfall volume estimate directly from point clouds) and the interaction of vegetation/hydraulics and sedimentation in salt marshes. These workflows use 2 recently published algorithms for point cloud classification (CANUPO) and point cloud comparison (M3C2) now implemented in the open source software CloudCompare.

  7. Simulation of surface tension in 2D and 3D with smoothed particle hydrodynamics method

    NASA Astrophysics Data System (ADS)

    Zhang, Mingyu

    2010-09-01

    The methods for simulating surface tension with smoothed particle hydrodynamics (SPH) method in two dimensions and three dimensions are developed. In 2D surface tension model, the SPH particle on the boundary in 2D is detected dynamically according to the algorithm developed by Dilts [G.A. Dilts, Moving least-squares particle hydrodynamics II: conservation and boundaries, International Journal for Numerical Methods in Engineering 48 (2000) 1503-1524]. The boundary curve in 2D is reconstructed locally with Lagrangian interpolation polynomial. In 3D surface tension model, the SPH particle on the boundary in 3D is detected dynamically according to the algorithm developed by Haque and Dilts [A. Haque, G.A. Dilts, Three-dimensional boundary detection for particle methods, Journal of Computational Physics 226 (2007) 1710-1730]. The boundary surface in 3D is reconstructed locally with moving least squares (MLS) method. By transforming the coordinate system, it is guaranteed that the interface function is one-valued in the local coordinate system. The normal vector and curvature of the boundary surface are calculated according to the reconstructed boundary surface and then surface tension force can be calculated. Surface tension force acts only on the boundary particle. Density correction is applied to the boundary particle in order to remove the boundary inconsistency. The surface tension models in 2D and 3D have been applied to benchmark tests for surface tension. The ability of the current method applying to the simulation of surface tension in 2D and 3D is proved.

  8. High-resolution, real-time simultaneous 3D surface geometry and temperature measurement.

    PubMed

    An, Yatong; Zhang, Song

    2016-06-27

    This paper presents a method to simultaneously measure three-dimensional (3D) surface geometry and temperature in real time. Specifically, we developed 1) a holistic approach to calibrate both a structured light system and a thermal camera under exactly the same world coordinate system even though these two sensors do not share the same wavelength; and 2) a computational framework to determine the sub-pixel corresponding temperature for each 3D point as well as discard those occluded points. Since the thermal 2D imaging and 3D visible imaging systems do not share the same spectrum of light, they can perform sensing simultaneously in real time: we developed a hardware system that can achieve real-time 3D geometry and temperature measurement at 26 Hz with 768 × 960 points per frame. PMID:27410608

  9. Characterizing the influence of surface roughness and inclination on 3D vision sensor performance

    NASA Astrophysics Data System (ADS)

    Hodgson, John R.; Kinnell, Peter; Justham, Laura; Jackson, Michael R.

    2015-12-01

    This paper reports a methodology to evaluate the performance of 3D scanners, focusing on the influence of surface roughness and inclination on the number of acquired data points and measurement noise. Point clouds were captured of samples mounted on a robotic pan-tilt stage using an Ensenso active stereo 3D scanner. The samples have isotropic texture and range in surface roughness (Ra) from 0.09 to 0.46 μm. By extracting the point cloud quality indicators, point density and standard deviation, at a multitude of inclinations, maps of scanner performance are created. These maps highlight the performance envelopes of the sensor, the aim being to predict and compare scanner performance on real-world surfaces, rather than idealistic artifacts. The results highlight the need to characterize 3D vision sensors by their measurement limits as well as best-case performance, determined either by theoretical calculation or measurements in ideal circumstances.

  10. High quality surface reconstruction in radiotherapy: Cross-sectional contours to 3D mesh using wavelets.

    PubMed

    Moriconi, S; Scalco, E; Broggi, S; Avuzzi, B; Valdagni, R; Rizzo, G

    2015-08-01

    A novel approach for three-dimensional (3D) surface reconstruction of anatomical structures in radiotherapy (RT) is presented. This is obtained from manual cross-sectional contours by combining both image voxel segmentation processing and implicit surface streaming methods using wavelets. 3D meshes reconstructed with the proposed approach are compared to those obtained from traditional triangulation algorithm. Qualitative and quantitative evaluations are performed in terms of mesh quality metrics. Differences in smoothness, detail and accuracy are observed in the comparison, considering three different anatomical districts and several organs at risk in radiotherapy. Overall best performances were recorded for the proposed approach, regardless the complexity of the anatomical structure. This demonstrates the efficacy of the proposed approach for the 3D surface reconstruction in radiotherapy and allows for further specific image analyses using real biomedical data. PMID:26737226

  11. 3D numerical simulation analysis of passive drag near free surface in swimming

    NASA Astrophysics Data System (ADS)

    Zhan, Jie-min; Li, Tian-zeng; Chen, Xue-bin; Li, Yok-sheung; Wai, Wing-hong Onyx

    2015-04-01

    The aim of this work is to build a 3D numerical model to study the characteristics of passive drag on competitive swimmers taking into account the impact of the free surface. This model solves the 3D incompressible Navier-Stokes equations using RNG k- ɛ turbulence closure. The volume of fluid (VOF) method is used to locate the free surface. The 3D virtual model is created by Computer Aided Industrial Design (CAID) software, Rhinoceros. Firstly, a specific posture of swimming is studied. The simulation results are in good agreement with the data from mannequin towing experiments. The effects of a swimmer's arms and legs positions on swimming performance are then studied. Finally, it is demonstrated that the present method is capable of simulating gliding near the free surface.

  12. surf3d: A 3-D finite-element program for the analysis of surface and corner cracks in solids subjected to mode-1 loadings

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Newman, J. C., Jr.

    1993-01-01

    A computer program, surf3d, that uses the 3D finite-element method to calculate the stress-intensity factors for surface, corner, and embedded cracks in finite-thickness plates with and without circular holes, was developed. The cracks are assumed to be either elliptic or part eliptic in shape. The computer program uses eight-noded hexahedral elements to model the solid. The program uses a skyline storage and solver. The stress-intensity factors are evaluated using the force method, the crack-opening displacement method, and the 3-D virtual crack closure methods. In the manual the input to and the output of the surf3d program are described. This manual also demonstrates the use of the program and describes the calculation of the stress-intensity factors. Several examples with sample data files are included with the manual. To facilitate modeling of the user's crack configuration and loading, a companion program (a preprocessor program) that generates the data for the surf3d called gensurf was also developed. The gensurf program is a three dimensional mesh generator program that requires minimal input and that builds a complete data file for surf3d. The program surf3d is operational on Unix machines such as CRAY Y-MP, CRAY-2, and Convex C-220.

  13. 3D surface reconstruction and visualization of the Drosophila wing imaginal disc at cellular resolution

    NASA Astrophysics Data System (ADS)

    Bai, Linge; Widmann, Thomas; Jülicher, Frank; Dahmann, Christian; Breen, David

    2013-01-01

    Quantifying and visualizing the shape of developing biological tissues provide information about the morphogenetic processes in multicellular organisms. The size and shape of biological tissues depend on the number, size, shape, and arrangement of the constituting cells. To better understand the mechanisms that guide tissues into their final shape, it is important to investigate the cellular arrangement within tissues. Here we present a data processing pipeline to generate 3D volumetric surface models of epithelial tissues, as well as geometric descriptions of the tissues' apical cell cross-sections. The data processing pipeline includes image acquisition, editing, processing and analysis, 2D cell mesh generation, 3D contourbased surface reconstruction, cell mesh projection, followed by geometric calculations and color-based visualization of morphological parameters. In their first utilization we have applied these procedures to construct a 3D volumetric surface model at cellular resolution of the wing imaginal disc of Drosophila melanogaster. The ultimate goal of the reported effort is to produce tools for the creation of detailed 3D geometric models of the individual cells in epithelial tissues. To date, 3D volumetric surface models of the whole wing imaginal disc have been created, and the apicolateral cell boundaries have been identified, allowing for the calculation and visualization of cell parameters, e.g. apical cross-sectional area of cells. The calculation and visualization of morphological parameters show position-dependent patterns of cell shape in the wing imaginal disc. Our procedures should offer a general data processing pipeline for the construction of 3D volumetric surface models of a wide variety of epithelial tissues.

  14. Modeling Images of Natural 3D Surfaces: Overview and Potential Applications

    NASA Technical Reports Server (NTRS)

    Jalobeanu, Andre; Kuehnel, Frank; Stutz, John

    2004-01-01

    Generative models of natural images have long been used in computer vision. However, since they only describe the of 2D scenes, they fail to capture all the properties of the underlying 3D world. Even though such models are sufficient for many vision tasks a 3D scene model is when it comes to inferring a 3D object or its characteristics. In this paper, we present such a generative model, incorporating both a multiscale surface prior model for surface geometry and reflectance, and an image formation process model based on realistic rendering, the computation of the posterior model parameter densities, and on the critical aspects of the rendering. We also how to efficiently invert the model within a Bayesian framework. We present a few potential applications, such as asteroid modeling and Planetary topography recovery, illustrated by promising results on real images.

  15. Generation of 3-D surface maps in waste storage silos using a structured light source

    NASA Technical Reports Server (NTRS)

    Burks, B. L.; Rowe, J. C.; Dinkins, M. A.; Christensen, B.; Selleck, C.; Jacoboski, D.; Markus, R.

    1992-01-01

    Surface contours inside the large waste storage tanks typical of the Department of Energy (DOE) complex are, in general, highly irregular. In addition to pipes and other pieces of equipment in the tanks, the surfaces may have features such as mounds, fissures, crystalline structures, and mixed solid and liquid forms. Prior to remediation activities, it will be necessary to characterize the waste to determine the most effective remediation approaches. Surface contour data will be required both prior to and during remediation. The use is described of a structured light source to generate 3-D surface contour maps of the interior of waste storage silos at the Feed Materials Production Center at Fernald, OH. The landscape inside these large waste storage tanks bears a strong resemblance to some of the landscapes that might be encountered during lunar or planetary exploration. Hence, these terrestrial 3-D mapping techniques may be directly applicable to extraterrestrial exploration. In further development, it will be demonstrated that these 3-D data can be used for robotic task planning just as 3-D surface contour data of a satellite could be used to plan maintenance tasks for a space-based servicing robot.

  16. 3D structural analysis of proteins using electrostatic surfaces based on image segmentation

    PubMed Central

    Vlachakis, Dimitrios; Champeris Tsaniras, Spyridon; Tsiliki, Georgia; Megalooikonomou, Vasileios; Kossida, Sophia

    2016-01-01

    Herein, we present a novel strategy to analyse and characterize proteins using protein molecular electro-static surfaces. Our approach starts by calculating a series of distinct molecular surfaces for each protein that are subsequently flattened out, thus reducing 3D information noise. RGB images are appropriately scaled by means of standard image processing techniques whilst retaining the weight information of each protein’s molecular electrostatic surface. Then homogeneous areas in the protein surface are estimated based on unsupervised clustering of the 3D images, while performing similarity searches. This is a computationally fast approach, which efficiently highlights interesting structural areas among a group of proteins. Multiple protein electrostatic surfaces can be combined together and in conjunction with their processed images, they can provide the starting material for protein structural similarity and molecular docking experiments.

  17. Detection and Reconstruction of an Implicit Boundary Surface by Adaptively Expanding A Small Surface Patch in a 3D Image.

    PubMed

    Wang, Lisheng; Wang, Pai; Cheng, Liuhang; Ma, Yu; Wu, Shenzhi; Wang, Yu-Ping; Xu, Zongben

    2014-11-01

    In this paper we propose a novel and easy to use 3D reconstruction method. With the method, users only need to specify a small boundary surface patch in a 2D section image, and then an entire continuous implicit boundary surface (CIBS) can be automatically reconstructed from a 3D image. In the method, a hierarchical tracing strategy is used to grow the known boundary surface patch gradually in the 3D image. An adaptive detection technique is applied to detect boundary surface patches from different local regions. The technique is based on both context dependence and adaptive contrast detection as in the human vision system. A recognition technique is used to distinguish true boundary surface patches from the false ones in different cubes. By integrating these different approaches, a high-resolution CIBS model can be automatically reconstructed by adaptively expanding the small boundary surface patch in the 3D image. The effectiveness of our method is demonstrated by its applications to a variety of real 3D images, where the CIBS with complex shapes/branches and with varying gray values/gradient magnitudes can be well reconstructed. Our method is easy to use, which provides a valuable tool for 3D image visualization and analysis as needed in many applications. PMID:26355329

  18. Controlled surface topography regulates collective 3D migration by epithelial-mesenchymal composite embryonic tissues.

    PubMed

    Song, Jiho; Shawky, Joseph H; Kim, YongTae; Hazar, Melis; LeDuc, Philip R; Sitti, Metin; Davidson, Lance A

    2015-07-01

    Cells in tissues encounter a range of physical cues as they migrate. Probing single cell and collective migratory responses to physically defined three-dimensional (3D) microenvironments and the factors that modulate those responses are critical to understanding how tissue migration is regulated during development, regeneration, and cancer. One key physical factor that regulates cell migration is topography. Most studies on surface topography and cell mechanics have been carried out with single migratory cells, yet little is known about the spreading and motility response of 3D complex multi-cellular tissues to topographical cues. Here, we examine the response to complex topographical cues of microsurgically isolated tissue explants composed of epithelial and mesenchymal cell layers from naturally 3D organized embryos of the aquatic frog Xenopus laevis. We control topography using fabricated micropost arrays (MPAs) and investigate the collective 3D migration of these multi-cellular systems in these MPAs. We find that the topography regulates both collective and individual cell migration and that dense MPAs reduce but do not eliminate tissue spreading. By modulating cell size through the cell cycle inhibitor Mitomycin C or the spacing of the MPAs we uncover how 3D topographical cues disrupt collective cell migration. We find surface topography can direct both single cell motility and tissue spreading, altering tissue-scale processes that enable efficient conversion of single cell motility into collective movement. PMID:25933063

  19. 3D-modeling of Callisto's sputtered surface-exosphere environment

    NASA Astrophysics Data System (ADS)

    Lammer, Helmut; Pfleger, Martin; Lindqvist, Jesper; Lichtenegger, Herbert; Holmström, Mats; Vorburger, Audrey; Wurz, Peter; Barabash, Stas

    2016-04-01

    We study the stoichiometrical release of various surface elements caused by plasma sputtering from an assumed icy and non-icy (i.e., chondritic) surface into the exosphere of the Jovian satellite Callisto. We apply a 3D plasma planetary interaction hybrid model that is used for the evaluation of precipitation maps of magnetospheric H+, O+ and S+ sputter agents onto Callisto's surface. The obtained precipitation maps are then applied to the assumed surface compositions where the related sputter yields are calculated by means of the 2013 SRIM code and are coupled with a 3D exosphere model. Sputtered surface particles are followed on their individual trajectories until they either escape Callisto's gravitational attraction or return to the surface. We study also the effect of collisions between sputter species and ambient O2 molecules which form a tiny atmosphere near the satellite's surface and compare the exosphere densities that are obtained from the 3D model with and without a background gaseous envelope with recent 1D model results. Finally we discuss if the Neutral gas and Ion Mass (NIM) spectrometer, that is part of the Particle Environment Package (PEP) on board of the JUICE mission will be able to detect sputtered particles from Callisto's icy and non-icy surface.

  20. Rate-constrained 3D surface estimation from noise-corrupted multiview depth videos.

    PubMed

    Sun, Wenxiu; Cheung, Gene; Chou, Philip A; Florencio, Dinei; Zhang, Cha; Au, Oscar C

    2014-07-01

    Transmitting compactly represented geometry of a dynamic 3D scene from a sender can enable a multitude of imaging functionalities at a receiver, such as synthesis of virtual images at freely chosen viewpoints via depth-image-based rendering. While depth maps—projections of 3D geometry onto 2D image planes at chosen camera viewpoints-can nowadays be readily captured by inexpensive depth sensors, they are often corrupted by non-negligible acquisition noise. Given depth maps need to be denoised and compressed at the encoder for efficient network transmission to the decoder, in this paper, we consider the denoising and compression problems jointly, arguing that doing so will result in a better overall performance than the alternative of solving the two problems separately in two stages. Specifically, we formulate a rate-constrained estimation problem, where given a set of observed noise-corrupted depth maps, the most probable (maximum a posteriori (MAP)) 3D surface is sought within a search space of surfaces with representation size no larger than a prespecified rate constraint. Our rate-constrained MAP solution reduces to the conventional unconstrained MAP 3D surface reconstruction solution if the rate constraint is loose. To solve our posed rate-constrained estimation problem, we propose an iterative algorithm, where in each iteration the structure (object boundaries) and the texture (surfaces within the object boundaries) of the depth maps are optimized alternately. Using the MVC codec for compression of multiview depth video and MPEG free viewpoint video sequences as input, experimental results show that rate-constrained estimated 3D surfaces computed by our algorithm can reduce coding rate of depth maps by up to 32% compared with unconstrained estimated surfaces for the same quality of synthesized virtual views at the decoder. PMID:24876124

  1. 3D surface topography of cylinder liner forecasting during plateau honing process

    NASA Astrophysics Data System (ADS)

    Reizer, R.; Pawlus, P.

    2011-08-01

    Areal surface topographies after plateau honing process were measured. A correlation analysis of surface texture parameters was then carried out. As the results, the following parameters describing plateau honed cylinder 3D surface topography were selected: amplitude Sq, Sz, spatial: Str, Std, hybrid SΔq as well as functional: Spq, Svq and Smq. 3D surface topographies were modeled. The modeled surface topographies were correctly matched to measured ones in 77% of all analyzed cases. The plateau honing experiment was then carried out using an orthogonal selective research plan. Two machining parameters were input variables: coarse honing pressure pv and plateau honing time t. Chosen cylinder liners texture parameters were output values. As the result of the experiment, regression equations connecting plateau honing process parameters pv and t with recommended 3D surface topography parameters were obtained. Finally, cylinder liner surface topographies were predicted for various values of machining parameters. Proper matching accuracy of modeled to measured textures was assured in 67% of analyzed cases.

  2. Optimal Image Stitching for Concrete Bridge Bottom Surfaces Aided by 3d Structure Lines

    NASA Astrophysics Data System (ADS)

    Liu, Yahui; Yao, Jian; Liu, Kang; Lu, Xiaohu; Xia, Menghan

    2016-06-01

    Crack detection for bridge bottom surfaces via remote sensing techniques is undergoing a revolution in the last few years. For such applications, a large amount of images, acquired with high-resolution industrial cameras close to the bottom surfaces with some mobile platform, are required to be stitched into a wide-view single composite image. The conventional idea of stitching a panorama with the affine model or the homographic model always suffers a series of serious problems due to poor texture and out-of-focus blurring introduced by depth of field. In this paper, we present a novel method to seamlessly stitch these images aided by 3D structure lines of bridge bottom surfaces, which are extracted from 3D camera data. First, we propose to initially align each image in geometry based on its rough position and orientation acquired with both a laser range finder (LRF) and a high-precision incremental encoder, and these images are divided into several groups with the rough position and orientation data. Secondly, the 3D structure lines of bridge bottom surfaces are extracted from the 3D cloud points acquired with 3D cameras, which impose additional strong constraints on geometrical alignment of structure lines in adjacent images to perform a position and orientation optimization in each group to increase the local consistency. Thirdly, a homographic refinement between groups is applied to increase the global consistency. Finally, we apply a multi-band blending algorithm to generate a large-view single composite image as seamlessly as possible, which greatly eliminates both the luminance differences and the color deviations between images and further conceals image parallax. Experimental results on a set of representative images acquired from real bridge bottom surfaces illustrate the superiority of our proposed approaches.

  3. 3D surface roughness measurement for scaliness scoring of psoriasis lesions.

    PubMed

    Ahmad Fadzil, M Hani; Prakasa, Esa; Asirvadam, Vijanth Sagayan; Nugroho, Hermawan; Affandi, Azura Mohd; Hussein, Suraiya Hani

    2013-11-01

    Psoriasis is an incurable skin disorder affecting 2-3% of the world population. The scaliness of psoriasis is a key assessment parameter of the Psoriasis Area and Severity Index (PASI). Dermatologists typically use visual and tactile senses in PASI scaliness assessment. However, the assessment can be subjective resulting in inter- and intra-rater variability in the scores. This paper proposes an assessment method that incorporates 3D surface roughness with standard clustering techniques to objectively determine the PASI scaliness score for psoriasis lesions. A surface roughness algorithm using structured light projection has been applied to 1999 3D psoriasis lesion surfaces. The algorithm has been validated with an accuracy of 94.12%. Clustering algorithms were used to classify the surface roughness measured using the proposed assessment method for PASI scaliness scoring. The reliability of the developed PASI scaliness algorithm was high with kappa coefficients>0.84 (almost perfect agreement). PMID:24054912

  4. Imaging SPR combined with stereoscopic 3D tracking to study barnacle cyprid-surface interactions

    NASA Astrophysics Data System (ADS)

    Maleshlijski, S.; Sendra, G. H.; Aldred, N.; Clare, A. S.; Liedberg, B.; Grunze, M.; Ederth, T.; Rosenhahn, A.

    2016-01-01

    Barnacle larvae (cyprids) explore surfaces to identify suitable settlement sites. This process is selective, and cyprids respond to numerous surface cues. To better understand the settlement process, it is desirable to simultaneously monitor both the surface exploration behavior and any close interactions with the surface. Stereoscopic 3D tracking of the cyprids provides quantitative access to surface exploration and pre-settlement rituals. Imaging surface plasmon resonance (SPR) reveals any interactions with the surfaces, such as surface inspection during bipedal walking and deposition of temporary adhesives. We report on a combination of both techniques to bring together information on swimming behavior in the vicinity of the interface and physical interactions of the cyprid with the surface. The technical requirements are described, and we applied the setup to cyprids of Balanus amphitrite. Initial data shows the applicability of the combined instrument to correlate exploration and touchdown events on surfaces with different chemical termination.

  5. An improved parallel SPH approach to solve 3D transient generalized Newtonian free surface flows

    NASA Astrophysics Data System (ADS)

    Ren, Jinlian; Jiang, Tao; Lu, Weigang; Li, Gang

    2016-08-01

    In this paper, a corrected parallel smoothed particle hydrodynamics (C-SPH) method is proposed to simulate the 3D generalized Newtonian free surface flows with low Reynolds number, especially the 3D viscous jets buckling problems are investigated. The proposed C-SPH method is achieved by coupling an improved SPH method based on the incompressible condition with the traditional SPH (TSPH), that is, the improved SPH with diffusive term and first-order Kernel gradient correction scheme is used in the interior of the fluid domain, and the TSPH is used near the free surface. Thus the C-SPH method possesses the advantages of two methods. Meanwhile, an effective and convenient boundary treatment is presented to deal with 3D multiple-boundary problem, and the MPI parallelization technique with a dynamic cells neighbor particle searching method is considered to improve the computational efficiency. The validity and the merits of the C-SPH are first verified by solving several benchmarks and compared with other results. Then the viscous jet folding/coiling based on the Cross model is simulated by the C-SPH method and compared with other experimental or numerical results. Specially, the influences of macroscopic parameters on the flow are discussed. All the numerical results agree well with available data, and show that the C-SPH method has higher accuracy and better stability for solving 3D moving free surface flows over other particle methods.

  6. Reconstructing White Walls: Multi-View Multi-Shot 3d Reconstruction of Textureless Surfaces

    NASA Astrophysics Data System (ADS)

    Ley, Andreas; Hänsch, Ronny; Hellwich, Olaf

    2016-06-01

    The reconstruction of the 3D geometry of a scene based on image sequences has been a very active field of research for decades. Nevertheless, there are still existing challenges in particular for homogeneous parts of objects. This paper proposes a solution to enhance the 3D reconstruction of weakly-textured surfaces by using standard cameras as well as a standard multi-view stereo pipeline. The underlying idea of the proposed method is based on improving the signal-to-noise ratio in weakly-textured regions while adaptively amplifying the local contrast to make better use of the limited numerical range in 8-bit images. Based on this premise, multiple shots per viewpoint are used to suppress statistically uncorrelated noise and enhance low-contrast texture. By only changing the image acquisition and adding a preprocessing step, a tremendous increase of up to 300% in completeness of the 3D reconstruction is achieved.

  7. 3D Surface Reconstruction of Plant Seeds by Volume Carving: Performance and Accuracies

    PubMed Central

    Roussel, Johanna; Geiger, Felix; Fischbach, Andreas; Jahnke, Siegfried; Scharr, Hanno

    2016-01-01

    We describe a method for 3D reconstruction of plant seed surfaces, focusing on small seeds with diameters as small as 200 μm. The method considers robotized systems allowing single seed handling in order to rotate a single seed in front of a camera. Even though such systems feature high position repeatability, at sub-millimeter object scales, camera pose variations have to be compensated. We do this by robustly estimating the tool center point from each acquired image. 3D reconstruction can then be performed by a simple shape-from-silhouette approach. In experiments we investigate runtimes, theoretically achievable accuracy, experimentally achieved accuracy, and show as a proof of principle that the proposed method is well sufficient for 3D seed phenotyping purposes. PMID:27375628

  8. On-machine measurement of the grinding wheels' 3D surface topography using a laser displacement sensor

    NASA Astrophysics Data System (ADS)

    Pan, Yongcheng; Zhao, Qingliang; Guo, Bing

    2014-08-01

    A method of non-contact, on-machine measurement of three dimensional surface topography of grinding wheels' whole surface was developed in this paper, focusing on an electroplated coarse-grained diamond grinding wheel. The measuring system consists of a Keyence laser displacement sensor, a Keyence controller and a NI PCI-6132 data acquisition card. A resolution of 0.1μm in vertical direction and 8μm in horizontal direction could be achieved. After processing the data by LabVIEW and MATLAB, the 3D topography of the grinding wheel's whole surface could be reconstructed. When comparing the reconstructed 3D topography of the grinding wheel's marked area to its real topography captured by a high-depth-field optical digital microscope (HDF-ODM) and scanning electron microscope (SEM), they were very similar to each other, proving that this method is accurate and effective. By a subsequent data processing, the topography of every grain could be extracted and then the active grain number, the active grain volume and the active grain's bearing ration could be calculated. These three parameters could serve as the criterion to evaluate the grinding performance of coarse-grained diamond grinding wheels. Then the performance of the grinding wheel could be evaluated on-machine accurately and quantitatively.

  9. Controlled implant/soft tissue interaction by nanoscale surface modifications of 3D porous titanium implants

    NASA Astrophysics Data System (ADS)

    Rieger, Elisabeth; Dupret-Bories, Agnès; Salou, Laetitia; Metz-Boutigue, Marie-Helene; Layrolle, Pierre; Debry, Christian; Lavalle, Philippe; Engin Vrana, Nihal

    2015-05-01

    Porous titanium implants are widely employed in the orthopaedics field to ensure good bone fixation. Recently, the use of porous titanium implants has also been investigated in artificial larynx development in a clinical setting. Such uses necessitate a better understanding of the interaction of soft tissues with porous titanium structures. Moreover, surface treatments of titanium have been generally evaluated in planar structures, while the porous titanium implants have complex 3 dimensional (3D) architectures. In this study, the determining factors for soft tissue integration of 3D porous titanium implants were investigated as a function of surface treatments via quantification of the interaction of serum proteins and cells with single titanium microbeads (300-500 μm in diameter). Samples were either acid etched or nanostructured by anodization. When the samples are used in 3D configuration (porous titanium discs of 2 mm thickness) in vivo (in subcutis of rats for 2 weeks), a better integration was observed for both anodized and acid etched samples compared to the non-treated implants. If the implants were also pre-treated with rat serum before implantation, the integration was further facilitated. In order to understand the underlying reasons for this effect, human fibroblast cell culture tests under several conditions (directly on beads, beads in suspension, beads encapsulated in gelatin hydrogels) were conducted to mimic the different interactions of cells with Ti implants in vivo. Physical characterization showed that surface treatments increased hydrophilicity, protein adsorption and roughness. Surface treatments also resulted in improved adsorption of serum albumin which in turn facilitated the adsorption of other proteins such as apolipoprotein as quantified by protein sequencing. The cellular response to the beads showed considerable difference with respect to the cell culture configuration. When the titanium microbeads were entrapped in cell

  10. Potential of ILRIS3D Intensity Data for Planar Surfaces Segmentation

    PubMed Central

    Wang, Chi-Kuei; Lu, Yao-Yu

    2009-01-01

    Intensity value based point cloud segmentation has received less attention because the intensity value of the terrestrial laser scanner is usually altered by receiving optics/hardware or the internal propriety software, which is unavailable to the end user. We offer a solution by assuming the terrestrial laser scanners are stable and the behavior of the intensity value can be characterized. Then, it is possible to use the intensity value for segmentation by observing its behavior, i.e., intensity value variation, pattern and presence of location of intensity values, etc. In this study, experiment results for characterizing the intensity data of planar surfaces collected by ILRIS3D, a terrestrial laser scanner, are reported. Two intensity formats, grey and raw, are employed by ILRIS3D. It is found from the experiment results that the grey intensity has less variation; hence it is preferable for point cloud segmentation. A warm-up time of approximate 1.5 hours is suggested for more stable intensity data. A segmentation method based on the visual cues of the intensity images sequence, which contains consecutive intensity images, is proposed in order to segment the 3D laser points of ILRIS3D. This method is unique to ILRIS3D data and does not require radiometric calibration. PMID:22346726

  11. Reconstruction Accuracy Assessment of Surface and Underwater 3D Motion Analysis: A New Approach

    PubMed Central

    de Jesus, Kelly; de Jesus, Karla; Figueiredo, Pedro; Vilas-Boas, João Paulo; Fernandes, Ricardo Jorge; Machado, Leandro José

    2015-01-01

    This study assessed accuracy of surface and underwater 3D reconstruction of a calibration volume with and without homography. A calibration volume (6000 × 2000 × 2500 mm) with 236 markers (64 above and 88 underwater control points—with 8 common points at water surface—and 92 validation points) was positioned on a 25 m swimming pool and recorded with two surface and four underwater cameras. Planar homography estimation for each calibration plane was computed to perform image rectification. Direct linear transformation algorithm for 3D reconstruction was applied, using 1600000 different combinations of 32 and 44 points out of the 64 and 88 control points for surface and underwater markers (resp.). Root Mean Square (RMS) error with homography of control and validations points was lower than without it for surface and underwater cameras (P ≤ 0.03). With homography, RMS errors of control and validation points were similar between surface and underwater cameras (P ≥ 0.47). Without homography, RMS error of control points was greater for underwater than surface cameras (P ≤ 0.04) and the opposite was observed for validation points (P ≤ 0.04). It is recommended that future studies using 3D reconstruction should include homography to improve swimming movement analysis accuracy. PMID:26175796

  12. An Interactive Virtual 3D Tool for Scientific Exploration of Planetary Surfaces

    NASA Astrophysics Data System (ADS)

    Traxler, Christoph; Hesina, Gerd; Gupta, Sanjeev; Paar, Gerhard

    2014-05-01

    In this paper we present an interactive 3D visualization tool for scientific analysis and planning of planetary missions. At the moment scientists have to look at individual camera images separately. There is no tool to combine them in three dimensions and look at them seamlessly as a geologist would do (by walking backwards and forwards resulting in different scales). For this reason a virtual 3D reconstruction of the terrain that can be interactively explored is necessary. Such a reconstruction has to consider multiple scales ranging from orbital image data to close-up surface image data from rover cameras. The 3D viewer allows seamless zooming between these various scales, giving scientists the possibility to relate small surface features (e.g. rock outcrops) to larger geological contexts. For a reliable geologic assessment a realistic surface rendering is important. Therefore the material properties of the rock surfaces will be considered for real-time rendering. This is achieved by an appropriate Bidirectional Reflectance Distribution Function (BRDF) estimated from the image data. The BRDF is implemented to run on the Graphical Processing Unit (GPU) to enable realistic real-time rendering, which allows a naturalistic perception for scientific analysis. Another important aspect for realism is the consideration of natural lighting conditions, which means skylight to illuminate the reconstructed scene. In our case we provide skylights from Mars and Earth, which allows switching between these two modes of illumination. This gives geologists the opportunity to perceive rock outcrops from Mars as they would appear on Earth facilitating scientific assessment. Besides viewing the virtual reconstruction on multiple scales, scientists can also perform various measurements, i.e. geo-coordinates of a selected point or distance between two surface points. Rover or other models can be placed into the scene and snapped onto certain location of the terrain. These are

  13. 3D Micropatterned Surface Inspired by Salvinia molesta via Direct Laser Lithography

    PubMed Central

    2015-01-01

    Biomimetic functional surfaces are attracting increasing attention for their relevant technological applications. Despite these efforts, inherent limitations of microfabrication techniques prevent the replication of complex hierarchical microstructures. Using a 3D laser lithography technique, we fabricated a 3D patterned surface bioinspired to Salvinia molesta leaves. The artificial hairs, with crownlike heads, were reproduced by scaling down (ca. 100 times smaller) the dimensions of natural features, so that microscale hairs with submicrometric resolution were attained. The micropatterned surface, in analogy with the natural model, shows interesting properties in terms of hydrophobicity and air retention when submerged by water, even if realized with a hydrophilic material. Furthermore, we successfully demonstrated the capability to promote localized condensation of water droplets from moisture in the atmosphere. PMID:26558410

  14. SU-E-J-209: Verification of 3D Surface Registration Between Stereograms and CT Images

    SciTech Connect

    Han, T; Gifford, K; Smith, B; Salehpour, M

    2014-06-01

    Purpose: Stereography can provide a visualization of the skin surface for radiation therapy patients. The aim of this study was to verify the registration algorithm in a commercial image analysis software, 3dMDVultus, for the fusion of stereograms and CT images. Methods: CT and stereographic scans were acquired of a head phantom and a deformable phantom. CT images were imported in 3dMDVultus and the surface contours were generated by threshold segmentation. Stereograms were reconstructed in 3dMDVultus. The resulting surfaces were registered with Vultus algorithm and then exported to in-house registration software and compared with four algorithms: rigid, affine, non-rigid iterative closest point (ICP) and b-spline algorithm. RMS (root-mean-square residuals of the surface point distances) error between the registered CT and stereogram surfaces was calculated and analyzed. Results: For the head phantom, the maximum RMS error between registered CT surfaces to stereogram was 6.6 mm for Vultus algorithm, whereas the mean RMS error was 0.7 mm. For the deformable phantom, the maximum RMS error was 16.2 mm for Vultus algorithm, whereas the mean RMS error was 4.4 mm. Non-rigid ICP demonstrated the best registration accuracy, as the mean of RMS errors were both within 1 mm. Conclusion: The accuracy of registration algorithm in 3dMDVultus was verified and exceeded RMS of 2 mm for deformable cases. Non-rigid ICP and b-spline algorithms improve the registration accuracy for both phantoms, especially in deformable one. For those patients whose body habitus deforms during radiation therapy, more advanced nonrigid algorithms need to be used.

  15. Evaluation Model for Pavement Surface Distress on 3d Point Clouds from Mobile Mapping System

    NASA Astrophysics Data System (ADS)

    Aoki, K.; Yamamoto, K.; Shimamura, H.

    2012-07-01

    This paper proposes a methodology to evaluate the pavement surface distress for maintenance planning of road pavement using 3D point clouds from Mobile Mapping System (MMS). The issue on maintenance planning of road pavement requires scheduled rehabilitation activities for damaged pavement sections to keep high level of services. The importance of this performance-based infrastructure asset management on actual inspection data is globally recognized. Inspection methodology of road pavement surface, a semi-automatic measurement system utilizing inspection vehicles for measuring surface deterioration indexes, such as cracking, rutting and IRI, have already been introduced and capable of continuously archiving the pavement performance data. However, any scheduled inspection using automatic measurement vehicle needs much cost according to the instruments' specification or inspection interval. Therefore, implementation of road maintenance work, especially for the local government, is difficult considering costeffectiveness. Based on this background, in this research, the methodologies for a simplified evaluation for pavement surface and assessment of damaged pavement section are proposed using 3D point clouds data to build urban 3D modelling. The simplified evaluation results of road surface were able to provide useful information for road administrator to find out the pavement section for a detailed examination and for an immediate repair work. In particular, the regularity of enumeration of 3D point clouds was evaluated using Chow-test and F-test model by extracting the section where the structural change of a coordinate value was remarkably achieved. Finally, the validity of the current methodology was investigated by conducting a case study dealing with the actual inspection data of the local roads.

  16. Illustrating Surface Shape in Volume Data via Principal Direction-Driven 3D Line Integral Convolution

    NASA Technical Reports Server (NTRS)

    Interrante, Victoria

    1997-01-01

    The three-dimensional shape and relative depth of a smoothly curving layered transparent surface may be communicated particularly effectively when the surface is artistically enhanced with sparsely distributed opaque detail. This paper describes how the set of principal directions and principal curvatures specified by local geometric operators can be understood to define a natural 'flow' over the surface of an object, and can be used to guide the placement of the lines of a stroke texture that seeks to represent 3D shape information in a perceptually intuitive way. The driving application for this work is the visualization of layered isovalue surfaces in volume data, where the particular identity of an individual surface is not generally known a priori and observers will typically wish to view a variety of different level surfaces from the same distribution, superimposed over underlying opaque structures. By advecting an evenly distributed set of tiny opaque particles, and the empty space between them, via 3D line integral convolution through the vector field defined by the principal directions and principal curvatures of the level surfaces passing through each gridpoint of a 3D volume, it is possible to generate a single scan-converted solid stroke texture that may intuitively represent the essential shape information of any level surface in the volume. To generate longer strokes over more highly curved areas, where the directional information is both most stable and most relevant, and to simultaneously downplay the visual impact of directional information in the flatter regions, one may dynamically redefine the length of the filter kernel according to the magnitude of the maximum principal curvature of the level surface at the point around which it is applied.

  17. A Generalized Approach to the Modeling and Analysis of 3D Surface Morphology in Organisms

    PubMed Central

    Pappas, Janice L.; Miller, Daniel J.

    2013-01-01

    The surface geometry of an organism represents the boundary of its three-dimensional (3D) form and can be used as a proxy for the phenotype. A mathematical approach is presented that describes surface morphology using parametric 3D equations with variables expressed as x, y, z in terms of parameters u, v. Partial differentiation of variables with respect to parameters yields elements of the Jacobian representing tangent lines and planes of every point on the surface. Jacobian elements provide a compact size-free summary of the entire surface, and can be used as variables in principal components analysis to produce a morphospace. Mollusk and echinoid models are generated to demonstrate that whole organisms can be represented in a common morphospace, regardless of differences in size, geometry, and taxonomic affinity. Models can be used to simulate theoretical forms, novel morphologies, and patterns of phenotypic variation, and can also be empirically-based by designing them with reference to actual forms using reverse engineering principles. Although this study uses the Jacobian to summarize models, they can also be analyzed with 3D methods such as eigensurface, spherical harmonics, wavelet analysis, and geometric morphometrics. This general approach should prove useful for exploring broad questions regarding morphological evolution and variation. PMID:24204866

  18. Coupling frontal photopolymerization and surface instabilities for a novel 3D patterning technology

    NASA Astrophysics Data System (ADS)

    Vitale, Alessandra; Hennessy, Matthew; Matar, Omar; Douglas, Jack; Cabral, João

    2015-03-01

    Patterning of soft matter provides an exceptional route for the generation of micro/nanostructured and functional surfaces. We describe a new 3D fabrication process based on coupling frontal photopolymerization (FPP) with precisely controlled, yet spontaneous, interfacial wrinkling. FPP is a complex spatio-temporal process that can lead to well-defined propagating fronts of network formation, both stable and unstable. We investigate this process focusing on the interfacial monomer-to-polymer conversion profile and its wave propagation. A simple coarse-grained model is found to describe remarkably well the planar frontal logarithmic kinetics, capturing the effects of UV light exposure time (or dose) and temperature, as well as the front position. In defined conditions, surface instabilities are introduced and interfere with wave planarity, resulting in the formation of ``minimal'' surfaces with complex 3D geometries. Building on this understanding on the propagation of wavefronts of network formation during photopolymerization, we demonstrate the design and fabrication of 3D patterned polymer materials with tunable shapes with optical and surface functionality.

  19. Accurate source location from P waves scattered by surface topography

    NASA Astrophysics Data System (ADS)

    Wang, N.; Shen, Y.

    2015-12-01

    Accurate source locations of earthquakes and other seismic events are fundamental in seismology. The location accuracy is limited by several factors, including velocity models, which are often poorly known. In contrast, surface topography, the largest velocity contrast in the Earth, is often precisely mapped at the seismic wavelength (> 100 m). In this study, we explore the use of P-coda waves generated by scattering at surface topography to obtain high-resolution locations of near-surface seismic events. The Pacific Northwest region is chosen as an example. The grid search method is combined with the 3D strain Green's tensor database type method to improve the search efficiency as well as the quality of hypocenter solution. The strain Green's tensor is calculated by the 3D collocated-grid finite difference method on curvilinear grids. Solutions in the search volume are then obtained based on the least-square misfit between the 'observed' and predicted P and P-coda waves. A 95% confidence interval of the solution is also provided as a posterior error estimation. We find that the scattered waves are mainly due to topography in comparison with random velocity heterogeneity characterized by the von Kάrmάn-type power spectral density function. When only P wave data is used, the 'best' solution is offset from the real source location mostly in the vertical direction. The incorporation of P coda significantly improves solution accuracy and reduces its uncertainty. The solution remains robust with a range of random noises in data, un-modeled random velocity heterogeneities, and uncertainties in moment tensors that we tested.

  20. Accurate source location from waves scattered by surface topography

    NASA Astrophysics Data System (ADS)

    Wang, Nian; Shen, Yang; Flinders, Ashton; Zhang, Wei

    2016-06-01

    Accurate source locations of earthquakes and other seismic events are fundamental in seismology. The location accuracy is limited by several factors, including velocity models, which are often poorly known. In contrast, surface topography, the largest velocity contrast in the Earth, is often precisely mapped at the seismic wavelength (>100 m). In this study, we explore the use of P coda waves generated by scattering at surface topography to obtain high-resolution locations of near-surface seismic events. The Pacific Northwest region is chosen as an example to provide realistic topography. A grid search algorithm is combined with the 3-D strain Green's tensor database to improve search efficiency as well as the quality of hypocenter solutions. The strain Green's tensor is calculated using a 3-D collocated-grid finite difference method on curvilinear grids. Solutions in the search volume are obtained based on the least squares misfit between the "observed" and predicted P and P coda waves. The 95% confidence interval of the solution is provided as an a posteriori error estimation. For shallow events tested in the study, scattering is mainly due to topography in comparison with stochastic lateral velocity heterogeneity. The incorporation of P coda significantly improves solution accuracy and reduces solution uncertainty. The solution remains robust with wide ranges of random noises in data, unmodeled random velocity heterogeneities, and uncertainties in moment tensors. The method can be extended to locate pairs of sources in close proximity by differential waveforms using source-receiver reciprocity, further reducing errors caused by unmodeled velocity structures.

  1. 3D scanning electron microscopy applied to surface characterization of fluorosed dental enamel.

    PubMed

    Limandri, Silvina; Galván Josa, Víctor; Valentinuzzi, María Cecilia; Chena, María Emilia; Castellano, Gustavo

    2016-05-01

    The enamel surfaces of fluorotic teeth were studied by scanning electron stereomicroscopy. Different whitening treatments were applied to 25 pieces to remove stains caused by fluorosis and their surfaces were characterized by stereomicroscopy in order to obtain functional and amplitude parameters. The topographic features resulting for each treatment were determined through these parameters. The results obtained show that the 3D reconstruction achieved from the SEM stereo pairs is a valuable potential alternative for the surface characterization of this kind of samples. PMID:26930005

  2. Direct laser writing of 3D polymer micro/nanostructures on metallic surfaces

    NASA Astrophysics Data System (ADS)

    Rekštytė, Sima; Žukauskas, Albertas; Purlys, Vytautas; Gordienko, Yuri; Malinauskas, Mangirdas

    2013-04-01

    Spectra of fields for applications of polymeric 3D micro/nanostructures are rapidly widening thus demanding the development of versatile precise and efficient fabrication methods that can be used to process a variety of materials and could be implemented to form tiny devices on a variety of surfaces without influencing their structural quality. We present the latest results obtained using laser lithography approach: 3D polymeric structures with submicrometer spatial resolution on different opaque surfaces such as semiconductors (Si) and various metals (Cr, Al, Fe and Ti). The photostructuring was performed using a range of photosensitive materials such as acrylate based AKRE23, acrylated biodegradable PEG-DA-258, epoxy based mr-NIL 6000, hybrid organic-inorganic SZ2080 and Ormocore b59.

  3. Direct laser writing of 3D micro/nanostructures on opaque surfaces

    NASA Astrophysics Data System (ADS)

    Rekštytė, Sima; Žukauskas, Albertas; Purlys, Vytautas; Gordienko, Yuri; Malinauskas, Mangirdas

    2012-06-01

    Spectra of fields for applications of polymeric 3D micro/nanostructures is rapidly widening thus demanding the development of versatile precise and efficient fabrication methods that can be used to process a variety of materials and could be implemented to form tiny devices on a variety of surfaces without influencing their structural quality. We present the latest results obtained using laser lithography approach: 3D polymeric structures with submicrometer spatial resolution on different opaque surfaces such as semiconductors (Si) and various metals (Cr, Al, Fe, Ti). The photostructuring was performed using a range of photosensitive materials such as acrylate based AKRE23, acrylated biodegradable PEG-DA-258, epoxy based mr-NIL 6000, hybrid organic-inorganic SZ2080 and Ormocore b59.

  4. Parallel Imaging of 3D Surface Profile with Space-Division Multiplexing

    PubMed Central

    Lee, Hyung Seok; Cho, Soon-Woo; Kim, Gyeong Hun; Jeong, Myung Yung; Won, Young Jae; Kim, Chang-Seok

    2016-01-01

    We have developed a modified optical frequency domain imaging (OFDI) system that performs parallel imaging of three-dimensional (3D) surface profiles by using the space division multiplexing (SDM) method with dual-area swept sourced beams. We have also demonstrated that 3D surface information for two different areas could be well obtained in a same time with only one camera by our method. In this study, double field of views (FOVs) of 11.16 mm × 5.92 mm were achieved within 0.5 s. Height range for each FOV was 460 µm and axial and transverse resolutions were 3.6 and 5.52 µm, respectively. PMID:26805840

  5. Nonrigid point registration for 2D curves and 3D surfaces and its various applications

    NASA Astrophysics Data System (ADS)

    Wang, Hesheng; Fei, Baowei

    2013-06-01

    A nonrigid B-spline-based point-matching (BPM) method is proposed to match dense surface points. The method solves both the point correspondence and nonrigid transformation without features extraction. The registration method integrates a motion model, which combines a global transformation and a B-spline-based local deformation, into a robust point-matching framework. The point correspondence and deformable transformation are estimated simultaneously by fuzzy correspondence and by a deterministic annealing technique. Prior information about global translation, rotation and scaling is incorporated into the optimization. A local B-spline motion model decreases the degrees of freedom for optimization and thus enables the registration of a larger number of feature points. The performance of the BPM method has been demonstrated and validated using synthesized 2D and 3D data, mouse MRI and micro-CT images. The proposed BPM method can be used to register feature point sets, 2D curves, 3D surfaces and various image data.

  6. An accurate 3D shape context based non-rigid registration method for mouse whole-body skeleton registration

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Zahra, David; Bourgeat, Pierrick; Berghofer, Paula; Acosta Tamayo, Oscar; Wimberley, Catriona; Gregoire, Marie C.; Salvado, Olivier

    2011-03-01

    Small animal image registration is challenging because of its joint structure, and posture and position difference in each acquisition without a standard scan protocol. In this paper, we face the issue of mouse whole-body skeleton registration from CT images. A novel method is developed for analyzing mouse hind-limb and fore-limb postures based on geodesic path descriptor and then registering the major skeletons and fore limb skeletons initially by thin-plate spline (TPS) transform based on the obtained geodesic paths and their enhanced correspondence fields. A target landmark correction method is proposed for improving the registration accuracy of the improved 3D shape context non-rigid registration method we previously proposed. A novel non-rigid registration framework, combining the skeleton posture analysis, geodesic path based initial alignment and 3D shape context model, is proposed for mouse whole-body skeleton registration. The performance of the proposed methods and framework was tested on 12 pairs of mouse whole-body skeletons. The experimental results demonstrated the flexibility, stability and accuracy of the proposed framework for automatic mouse whole body skeleton registration.

  7. A statistical model of ChIA-PET data for accurate detection of chromatin 3D interactions

    PubMed Central

    Paulsen, Jonas; Rødland, Einar A.; Holden, Lars; Holden, Marit; Hovig, Eivind

    2014-01-01

    Identification of three-dimensional (3D) interactions between regulatory elements across the genome is crucial to unravel the complex regulatory machinery that orchestrates proliferation and differentiation of cells. ChIA-PET is a novel method to identify such interactions, where physical contacts between regions bound by a specific protein are quantified using next-generation sequencing. However, determining the significance of the observed interaction frequencies in such datasets is challenging, and few methods have been proposed. Despite the fact that regions that are close in linear genomic distance have a much higher tendency to interact by chance, no methods to date are capable of taking such dependency into account. Here, we propose a statistical model taking into account the genomic distance relationship, as well as the general propensity of anchors to be involved in contacts overall. Using both real and simulated data, we show that the previously proposed statistical test, based on Fisher's exact test, leads to invalid results when data are dependent on genomic distance. We also evaluate our method on previously validated cell-line specific and constitutive 3D interactions, and show that relevant interactions are significant, while avoiding over-estimating the significance of short nearby interactions. PMID:25114054

  8. Direct ambient noise tomography for 3-D near surface shear velocity structure: methodology and applications

    NASA Astrophysics Data System (ADS)

    Yao, H.; Fang, H.; Li, C.; Liu, Y.; Zhang, H.; van der Hilst, R. D.; Huang, Y. C.

    2014-12-01

    Ambient noise tomography has provided essential constraints on crustal and uppermost mantle shear velocity structure in global seismology. Recent studies demonstrate that high frequency (e.g., ~ 1 Hz) surface waves between receivers at short distances can be successfully retrieved from ambient noise cross-correlation and then be used for imaging near surface or shallow crustal shear velocity structures. This approach provides important information for strong ground motion prediction in seismically active area and overburden structure characterization in oil and gas fields. Here we propose a new tomographic method to invert all surface wave dispersion data for 3-D variations of shear wavespeed without the intermediate step of phase or group velocity maps.The method uses frequency-dependent propagation paths and a wavelet-based sparsity-constrained tomographic inversion. A fast marching method is used to compute, at each period, surface wave traveltimes and ray paths between sources and receivers. This avoids the assumption of great-circle propagation that is used in most surface wave tomographic studies, but which is not appropriate in complex media. The wavelet coefficients of the velocity model are estimated with an iteratively reweighted least squares (IRLS) algorithm, and upon iterations the surface wave ray paths and the data sensitivity matrix are updated from the newly obtained velocity model. We apply this new method to determine the 3-D near surface wavespeed variations in the Taipei basin of Taiwan, Hefei urban area and a shale and gas production field in China using the high-frequency interstation Rayleigh wave dispersion data extracted from ambient noisecross-correlation. The results reveal strong effects of off-great-circle propagation of high-frequency surface waves in these regions with above 30% shear wavespeed variations. The proposed approach is more efficient and robust than the traditional two-step surface wave tomography for imaging complex

  9. A laminar cortical model of stereopsis and 3D surface perception: closure and da Vinci stereopsis.

    PubMed

    Cao, Yongqiang; Grossberg, Stephen

    2005-01-01

    A laminar cortical model of stereopsis and 3D surface perception is developed and simulated. The model describes how monocular and binocular oriented filtering interact with later stages of 3D boundary formation and surface filling-in in the LGN and cortical areas V1, V2, and V4. It proposes how interactions between layers 4, 3B, and 2/3 in V1 and V2 contribute to stereopsis, and how binocular and monocular information combine to form 3D boundary and surface representations. The model includes two main new developments: (1) It clarifies how surface-to-boundary feedback from V2 thin stripes to pale stripes helps to explain data about stereopsis. This feedback has previously been used to explain data about 3D figure-ground perception. (2) It proposes that the binocular false match problem is subsumed under the Gestalt grouping problem. In particular, the disparity filter, which helps to solve the correspondence problem by eliminating false matches, is realized using inhibitory interneurons as part of the perceptual grouping process by horizontal connections in layer 2/3 of cortical area V2. The enhanced model explains all the psychophysical data previously simulated by Grossberg and Howe (2003), such as contrast variations of dichoptic masking and the correspondence problem, the effect of interocular contrast differences on stereoacuity, Panum's limiting case, the Venetian blind illusion, stereopsis with polarity-reversed stereograms, and da Vinci stereopsis. It also explains psychophysical data about perceptual closure and variations of da Vinci stereopsis that previous models cannot yet explain. PMID:16312095

  10. Using 3D Printers to Model Earth Surface Topography for Increased Student Understanding and Retention

    NASA Astrophysics Data System (ADS)

    Thesenga, David; Town, James

    2014-05-01

    In February 2000, the Space Shuttle Endeavour flew a specially modified radar system during an 11-day mission. The purpose of the multinational Shuttle Radar Topography Mission (SRTM) was to "obtain elevation data on a near-global scale to generate the most complete high-resolution digital topographic database of Earth" by using radar interferometry. The data and resulting products are now publicly available for download and give a view of the landscape removed of vegetation, buildings, and other structures. This new view of the Earth's topography allows us to see previously unmapped or poorly mapped regions of the Earth as well as providing a level of detail that was previously unknown using traditional topographic mapping techniques. Understanding and appreciating the geographic terrain is a complex but necessary requirement for middle school aged (11-14yo) students. Abstract in nature, topographic maps and other 2D renderings of the Earth's surface and features do not address the inherent spatial challenges of a concrete-learner and traditional methods of teaching can at times exacerbate the problem. Technological solutions such as 3D-imaging in programs like Google Earth are effective but lack the tactile realness that can make a large difference in learning comprehension and retention for these young students. First developed in the 1980's, 3D printers were not commercial reality until recently and the rapid rise in interest has driven down the cost. With the advent of sub US1500 3D printers, this technology has moved out of the high-end marketplace and into the local office supply store. Schools across the US and elsewhere in the world are adding 3D printers to their technological workspaces and students have begun rapid-prototyping and manufacturing a variety of projects. This project attempted to streamline the process of transforming SRTM data from a GeoTIFF format by way of Python code. The resulting data was then inputted into a CAD-based program for

  11. 3D surface imaging of the human female torso in upright to supine positions.

    PubMed

    Reece, Gregory P; Merchant, Fatima; Andon, Johnny; Khatam, Hamed; Ravi-Chandar, K; Weston, June; Fingeret, Michelle C; Lane, Chris; Duncan, Kelly; Markey, Mia K

    2015-04-01

    Three-dimensional (3D) surface imaging of breasts is usually done with the patient in an upright position, which does not permit comparison of changes in breast morphology with changes in position of the torso. In theory, these limitations may be eliminated if the 3D camera system could remain fixed relative to the woman's torso as she is tilted from 0 to 90°. We mounted a 3dMDtorso imaging system onto a bariatric tilt table to image breasts at different tilt angles. The images were validated using a rigid plastic mannequin and the metrics compared to breast metrics obtained from five subjects with diverse morphology. The differences between distances between the same fiducial marks differed between the supine and upright positions by less than 1% for the mannequin, whereas the differences for distances between the same fiducial marks on the breasts of the five subjects differed significantly and could be correlated with body mass index and brassiere cup size for each position change. We show that a tilt table-3D imaging system can be used to determine quantitative changes in the morphology of ptotic breasts when the subject is tilted to various angles. PMID:25703742

  12. 3D Surface Imaging of the Human Female Torso in Upright to Supine Positions

    PubMed Central

    Reece, Gregory P.; Merchant, Fatima; Andon, Johnny; Khatam, Hamed; Ravi-Chandar, K.; Weston, June; Fingeret, Michelle C.; Lane, Chris; Duncan, Kelly; Markey, Mia K.

    2015-01-01

    Three-dimensional (3D) surface imaging of breasts is usually done with the patient in an upright position, which does not permit comparison of changes in breast morphology with changes in position of the torso. In theory, these limitations may be eliminated if the 3D camera system could remain fixed relative to the woman’s torso as she is tilted from 0 to 90 degrees. We mounted a 3dMDtorso imaging system onto a bariatric tilt table to image breasts at different tilt angles. The images were validated using a rigid plastic mannequin and the metrics compared to breast metrics obtained from 5 subjects with diverse morphology. The differences between distances between the same fiducial marks differed between the supine and upright positions by less than one percent for the mannequin, whereas the differences for distances between the same fiducial marks on the breasts of the 5 subjects differed significantly and could be correlated with body mass index and brassiere cup size for each position change. We show that a tilt table - 3D imaging system can be used to determine quantitative changes in the morphology of ptotic breasts when the subject is tilted to various angles. PMID:25703742

  13. Efficient near-real-time monitoring of 3D surface displacements in complex landslide scenarios

    NASA Astrophysics Data System (ADS)

    Allasia, Paolo; Manconi, Andrea; Giordan, Daniele; Baldo, Marco; Lollino, Giorgio

    2013-04-01

    Ground deformation measurements play a key role in monitoring activities of landslides. A wide spectrum of instruments and methods is nowadays available, going from in-situ to remote sensing approaches. In emergency scenarios, monitoring is often based on automated instruments capable to achieve accurate measurements, possibly with a very high temporal resolution, in order to achieve the best information about the evolution of the landslide in near-real-time, aiming at early warning purposes. However, the available tools for a rapid and efficient exploitation, understanding and interpretation of the retrieved measurements is still a challenge. This issue is particularly relevant in contexts where monitoring is fundamental to support early warning systems aimed at ensuring safety to people and/or infrastructures. Furthermore, in many cases the results obtained might be of difficult reading and divulgation, especially when people of different backgrounds are involved (e.g. scientists, authorities, civil protection operators, decision makers, etc.). In this work, we extend the concept of automatic and near real time from the acquisition of measurements to the data processing and divulgation, in order to achieve an efficient monitoring of surface displacements in landslide scenarios. We developed an algorithm that allows to go automatically and in near-real-time from the acquisition of 3D displacements on a landslide area to the efficient divulgation of the monitoring results via WEB. This set of straightforward procedures is called ADVICE (ADVanced dIsplaCement monitoring system for Early warning), and has been already successfully applied in several emergency scenarios. The algorithm includes: (i) data acquisition and transfer protocols; (ii) data collection, filtering, and validation; (iii) data analysis and restitution through a set of dedicated software, such as ©3DA [1]; (iv) recognition of displacement/velocity threshold and early warning (v) short term

  14. Feature, design intention and constraint preservation for direct modeling of 3D freeform surfaces

    NASA Astrophysics Data System (ADS)

    Fu, Luoting; Kara, Levent Burak; Shimada, Kenji

    2012-06-01

    Direct modeling has recently emerged as a suitable approach for 3D free-form shape modeling in industrial design. It has several advantages over the conventional, parametric modeling techniques, including natural user interactions, as well as the underlying, automatic feature-preserving shape deformation algorithms. However, current direct modeling packages still lack several capabilities critical for product design, such as managing aesthetic design intentions, and enforcing dimensional, geometric constraints. In this paper, we describe a novel 3D surface editing system capable of jointly accommodating aesthetic design intentions expressed in the form of surface painting and color-coded annotations, as well as engineering constraints expressed as dimensions. The proposed system is built upon differential coordinates and constrained least squares, and is intended for conceptual design that involves frequent shape tuning and explorations. We also provide an extensive review of the state-of-the-art direct modeling approaches for 3D mesh-based, freeform surfaces, with an emphasis on the two broad categories of shape deformation algorithms developed in the relevant field of geometric modeling. [Figure not available: see fulltext.

  15. State of the art of 3D scanning systems and inspection of textile surfaces

    NASA Astrophysics Data System (ADS)

    Montilla, M.; Orjuela-Vargas, S. A.; Philips, W.

    2014-02-01

    The rapid development of hardware and software in the digital image processing field has boosted research in computer vision for applications in industry. The development of new electronic devices and the tendency to decrease their prices makes possible new developments that few decades ago were possible only in the imagination. This is the case of 3D imaging technology which permits to detect failures in industrial products by inspecting aspects on their 3D surface. In search of an optimal solution for scanning textiles we present in this paper a review of existing techniques for digitizing 3D surfaces. Topographic details of textiles can be obtained by digitizing surfaces using laser line triangulation, phase shifting optical triangulation, projected-light, stereo-vision systems and silhouette analysis. Although we are focused on methods that have been used in the textile industry, we also consider potential mechanisms used for other applications. We discuss the advantages and disadvantages of the evaluated methods and state a summary of potential implementations for the textile industry.

  16. 3D surface scan of biological samples with a Push-broom Imaging Spectrometer

    NASA Astrophysics Data System (ADS)

    Yao, Haibo; Kincaid, Russell; Hruska, Zuzana; Brown, Robert L.; Bhatnagar, Deepak; Cleveland, Thomas E.

    2013-08-01

    The food industry is always on the lookout for sensing technologies for rapid and nondestructive inspection of food products. Hyperspectral imaging technology integrates both imaging and spectroscopy into unique imaging sensors. Its application for food safety and quality inspection has made significant progress in recent years. Specifically, hyperspectral imaging has shown its potential for surface contamination detection in many food related applications. Most existing hyperspectral imaging systems use pushbroom scanning which is generally used for flat surface inspection. In some applications it is desirable to be able to acquire hyperspectral images on circular objects such as corn ears, apples, and cucumbers. Past research describes inspection systems that examine all surfaces of individual objects. Most of these systems did not employ hyperspectral imaging. These systems typically utilized a roller to rotate an object, such as an apple. During apple rotation, the camera took multiple images in order to cover the complete surface of the apple. The acquired image data lacked the spectral component present in a hyperspectral image. This paper discusses the development of a hyperspectral imaging system for a 3-D surface scan of biological samples. The new instrument is based on a pushbroom hyperspectral line scanner using a rotational stage to turn the sample. The system is suitable for whole surface hyperspectral imaging of circular objects. In addition to its value to the food industry, the system could be useful for other applications involving 3-D surface inspection.

  17. Uniform metal patterning on micromachined 3D surfaces using multistep exposure of UV light

    NASA Astrophysics Data System (ADS)

    Suriadi, Arief; Berauer, Frank; Yasunaga, Akari; Pan, Alfred I.; Vander Plas, Hubert A.

    2002-07-01

    Focal depth limitations prevent use of normal lithography tools and processes on three-dimensional structures. A relatively little known form of uniform metal trace patterning over extreme 3-D structured wafers by a multi-step exposure method, called stitching technology, has recently been developed by Hewlett-Packard Company, with equipment support from the Ultratech Stepper Company, the result of which is being reported in this paper. The basic idea is to slice the metal lines to be patterned into topographic layers that can each be exposed in one step. Patches of patterned metal lines can thus be stitch-ed to one another (thus, the term stitching). Exposure of one photo-resist layer by stitching takes several individual exposures at different focus planes. A patent has been applied for this method on behalf of the Hewlett Packard Company. Results of the present investigation demonstrate the superior uniformity of metal trace pattern over 350-um deep trenches produced by multi-step exposure, as compared to the conventional single-step exposure method, typically used on planar semiconductor wafer. The integrated method offers an enabling technology for patterning of extensive topography typically required for a multitude of MEMS structures and designs, novel interconnect structures as well as advanced packaging applications. The method is simple, accurate and relatively low-cost in comparison with other 3-D exposure techniques available and capable of 3-D structure patterning.

  18. Assessment of Ulcer Wounds Size Using 3D Skin Surface Imaging

    NASA Astrophysics Data System (ADS)

    Hani, Ahmad Fadzil M.; Eltegani, Nejood M.; Hussein, Suraiya H.; Jamil, Adawiyah; Gill, Priya

    In this work 3D surface scans of wounds are used to obtain several measurement including wound top area, true surface area (rue area), depth, and volume for the purpose of assessing the progress of ulcer wounds throughout treatment. KONICA MINOLTA 910 laser scanner is used to obtain the surface scans. The algorithm for estimating top area and true surface area from surface scan can reduce the inaccuracy that might result when using manual method. Two methods for solid construction and volume computation were considered; namely mid-point projection and convex hull approximation (Delaunay tetrahedralization). The performance of convex hull approximation method for volume estimation is improved by performing surface subdivision prior to the approximation. The performance of these algorithms on different patterns of simulated wound models is presented. Furthermore the algorithms are tested in two molded wounds printed using rapid prototyping (RP) technique.

  19. Accurate 3D rigid-body target motion and structure estimation by using GMTI/HRR with template information

    NASA Astrophysics Data System (ADS)

    Wu, Shunguang; Hong, Lang

    2008-04-01

    A framework of simultaneously estimating the motion and structure parameters of a 3D object by using high range resolution (HRR) and ground moving target indicator (GMTI) measurements with template information is given. By decoupling the motion and structure information and employing rigid-body constraints, we have developed the kinematic and measurement equations of the problem. Since the kinematic system is unobservable by using only one scan HRR and GMTI measurements, we designed an architecture to run the motion and structure filters in parallel by using multi-scan measurements. Moreover, to improve the estimation accuracy in large noise and/or false alarm environments, an interacting multi-template joint tracking (IMTJT) algorithm is proposed. Simulation results have shown that the averaged root mean square errors for both motion and structure state vectors have been significantly reduced by using the template information.

  20. Defining an optimal surface chemistry for pluripotent stem cell culture in 2D and 3D

    NASA Astrophysics Data System (ADS)

    Zonca, Michael R., Jr.

    Surface chemistry is critical for growing pluripotent stem cells in an undifferentiated state. There is great potential to engineer the surface chemistry at the nanoscale level to regulate stem cell adhesion. However, the challenge is to identify the optimal surface chemistry of the substrata for ES cell attachment and maintenance. Using a high-throughput polymerization and screening platform, a chemically defined, synthetic polymer grafted coating that supports strong attachment and high expansion capacity of pluripotent stem cells has been discovered using mouse embryonic stem (ES) cells as a model system. This optimal substrate, N-[3-(Dimethylamino)propyl] methacrylamide (DMAPMA) that is grafted on 2D synthetic poly(ether sulfone) (PES) membrane, sustains the self-renewal of ES cells (up to 7 passages). DMAPMA supports cell attachment of ES cells through integrin beta1 in a RGD-independent manner and is similar to another recently reported polymer surface. Next, DMAPMA has been able to be transferred to 3D by grafting to synthetic, polymeric, PES fibrous matrices through both photo-induced and plasma-induced polymerization. These 3D modified fibers exhibited higher cell proliferation and greater expression of pluripotency markers of mouse ES cells than 2D PES membranes. Our results indicated that desirable surfaces in 2D can be scaled to 3D and that both surface chemistry and structural dimension strongly influence the growth and differentiation of pluripotent stem cells. Lastly, the feasibility of incorporating DMAPMA into a widely used natural polymer, alginate, has been tested. Novel adhesive alginate hydrogels have been successfully synthesized by either direct polymerization of DMAPMA and methacrylic acid blended with alginate, or photo-induced DMAPMA polymerization on alginate nanofibrous hydrogels. In particular, DMAPMA-coated alginate hydrogels support strong ES cell attachment, exhibiting a concentration dependency of DMAPMA. This research provides a

  1. Melt-rock reaction in the asthenospheric mantle: Perspectives from high-order accurate numerical simulations in 2D and 3D

    NASA Astrophysics Data System (ADS)

    Tirupathi, S.; Schiemenz, A. R.; Liang, Y.; Parmentier, E.; Hesthaven, J.

    2013-12-01

    The style and mode of melt migration in the mantle are important to the interpretation of basalts erupted on the surface. Both grain-scale diffuse porous flow and channelized melt migration have been proposed. To better understand the mechanisms and consequences of melt migration in a heterogeneous mantle, we have undertaken a numerical study of reactive dissolution in an upwelling and viscously deformable mantle where solubility of pyroxene increases upwards. Our setup is similar to that described in [1], except we use a larger domain size in 2D and 3D and a new numerical method. To enable efficient simulations in 3D through parallel computing, we developed a high-order accurate numerical method for the magma dynamics problem using discontinuous Galerkin methods and constructed the problem using the numerical library deal.II [2]. Linear stability analyses of the reactive dissolution problem reveal three dynamically distinct regimes [3] and the simulations reported in this study were run in the stable regime and the unstable wave regime where small perturbations in porosity grows periodically. The wave regime is more relevant to melt migration beneath the mid-ocean ridges but computationally more challenging. Extending the 2D simulations in the stable regime in [1] to 3D using various combinations of sustained perturbations in porosity at the base of the upwelling column (which may result from a viened mantle), we show the geometry and distribution of dunite channel and high-porosity melt channels are highly correlated with inflow perturbation through superposition. Strong nonlinear interactions among compaction, dissolution, and upwelling give rise to porosity waves and high-porosity melt channels in the wave regime. These compaction-dissolution waves have well organized but time-dependent structures in the lower part of the simulation domain. High-porosity melt channels nucleate along nodal lines of the porosity waves, growing downwards. The wavelength scales

  2. Surface states in a 3D topological insulator: The role of hexagonal warping and curvature

    SciTech Connect

    Repin, E. V.; Burmistrov, I. S.

    2015-09-15

    We explore a combined effect of hexagonal warping and a finite effective mass on both the tunneling density of electronic surface states and the structure of Landau levels of 3D topological insulators. We find the increasing warping to transform the square-root van Hove singularity into a logarithmic one. For moderate warping, an additional logarithmic singularity and a jump in the tunneling density of surface states appear. By combining the perturbation theory and the WKB approximation, we calculate the Landau levels in the presence of hexagonal warping. We predict that due to the degeneracy removal, the evolution of Landau levels in the magnetic field is drastically modified.

  3. Surface processes on the asteroid deduced from the external 3D shapes and surface features of Itokawa particles

    NASA Astrophysics Data System (ADS)

    Tsuchiyama, A.; Matsumoto, T.

    2015-10-01

    Particles on the surface of S-type Asteroid 25143 Itokawa were successfully recovered by the Hayabusa mission of JAXA (e.g., [1,2]). They are not only the first samples recovered from an asteroid, but also the second extraterrestrial regolith to have been sampled, the first being the Moon by Apollo and Luna missions. The analysis of tiny sample particles (20-200 μm) shows that the Itokawa surface material is consistent with LL chondrites suffered by space weathering as expected and brought an end to the origin of meteorites (e.g., [2-4]). In addition, the examination of Itokawa particles allow studies of surface processes on the asteroid because regolith particles can be regarded as an interface with the space environment, where the impacts of small objects and irradiation by the solar wind and galactic cosmic rays should have been recorded. External 3D shapes and surface features of Itokawa regolith particles were examined. Two kinds of surface modification, formation of space-weathering rims mainly by solar wind implantation and surface abrasion by grain migration, were recognized. Spectral change of the asteroid proceeded by formation of space-weathering rims and refreshment of the regolith surfaces. External 3D shapes and surface morphologies of the regolith particles can provide information about formation and evolution history of regolith particles in relation to asteroidal surface processes. 3D shapes of Itokawa regolith particles were obtained using microtomography [3]. The surface nanomiromorpholgy of Itokawa particles were also observed using FE-SEM [5]. However, the number of particles was limited and genial feature on the surface morphology has not been understood. In this study, the surface morphology of Itokawa regolith particles was systematically investigated together with their 3D structures.

  4. SU-E-J-128: 3D Surface Reconstruction of a Patient Using Epipolar Geometry

    SciTech Connect

    Kotoku, J; Nakabayashi, S; Kumagai, S; Ishibashi, T; Kobayashi, T; Haga, A; Saotome, N; Arai, N

    2014-06-01

    Purpose: To obtain a 3D surface data of a patient in a non-invasive way can substantially reduce the effort for the registration of patient in radiation therapy. To achieve this goal, we introduced the multiple view stereo technique, which is known to be used in a 'photo tourism' on the internet. Methods: 70 Images were taken with a digital single-lens reflex camera from different angles and positions. The camera positions and angles were inferred later in the reconstruction step. A sparse 3D reconstruction model was locating by SIFT features, which is robust for rotation and shift variance, in each image. We then found a set of correspondences between pairs of images by computing the fundamental matrix using the eight-point algorithm with RANSAC. After the pair matching, we optimized the parameter including camera positions to minimize the reprojection error by use of bundle adjustment technique (non-linear optimization). As a final step, we performed dense reconstruction and associate a color with each point using the library of PMVS. Results: Surface data were reconstructed well by visual inspection. The human skin is reconstructed well, althogh the reconstruction was time-consuming for direct use in daily clinical practice. Conclusion: 3D reconstruction using multi view stereo geometry is a promising tool for reducing the effort of patient setup. This work was supported by JSPS KAKENHI(25861128)

  5. Large-area fabrication of 3D petal-like nanopattern for surface enhanced Raman scattering

    NASA Astrophysics Data System (ADS)

    Zhou, Weimin; Wang, Jinhe; Zhang, Jing; Li, Xiaoli; Min, Guoquan

    2014-06-01

    A very easy and flexible approach to fabricate large area, petal-like nanopattern for surface enhanced Raman scattering using soft imprint lithography are presented here. The morphology of the petal-like nanopattern can be transferred truly using the h-PDMS and diluted PMMA molding template. By means of Au metal deposition, a SERS substrate with high enhancement factor over large area, which is still a problem, was produced easily. The morphology and Raman enhancement effect of the 3D nanopattern are characterized by SEM, AFM and SERS. The results show that the petal-like 3D nanopattern has high SERS enhancement factor (order of 1.0 × 108) and could be a promising low cost and high performance SERS active substrate.

  6. A fast method to measure the 3D surface of the human heart

    NASA Astrophysics Data System (ADS)

    Cao, Yiping; Su, Xianyu; Xiang, Liqun; Chen, Wenjing; Zhang, Qican

    2003-12-01

    Three-dimensional (3-D) automatic measurement of an object is widely used in many fields. In Biology and Medicine society, it can be applicable for surgery, orthopedics, viscera disease analysis and diagnosis etc. Here a new fast method to measure the 3D surface of human heart is proposed which can provide doctors a lot of information, such as the size of heart profile, the sizes of the left or right heart ventricle, and the curvature center and radius of heart ventricle, to fully analyze and diagnose pathobiology of human heart. The new fast method is optically and noncontacted and based upon the Phase Measurement Profilometry (PMP), which has higher measuring precision. A human heart specimen experiment has verified our method.

  7. An improved 3D shape context registration method for non-rigid surface registration

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Zahra, David; Bourgeat, Pierrick; Berghofer, Paula; Acosta Tamayo, Oscar; Wimberley, Catriona; Gregoire, Marie-Claude; Salvado, Olivier

    2010-03-01

    3D shape context is a method to define matching points between similar shapes as a pre-processing step to non-rigid registration. The main limitation of the approach is point mismatching, which includes long geodesic distance mismatch and neighbors crossing mismatch. In this paper, we propose a topological structure verification method to correct the long geodesic distance mismatch and a correspondence field smoothing method to correct the neighbors crossing mismatch. A robust 3D shape context model is proposed and further combined with thin-plate spline model for non-rigid surface registration. The method was tested on phantoms and rat hind limb skeletons from micro CT images. The results from experiments on mouse hind limb skeletons indicate that the approach is robust.

  8. Maximum likelihood estimation of parameterized 3-D surfaces using a moving camera

    NASA Technical Reports Server (NTRS)

    Hung, Y.; Cernuschi-Frias, B.; Cooper, D. B.

    1987-01-01

    A new approach is introduced to estimating object surfaces in three-dimensional space from a sequence of images. A surface of interest here is modeled as a 3-D function known up to the values of a few parameters. The approach will work with any parameterization. However, in work to date researchers have modeled objects as patches of spheres, cylinders, and planes - primitive objects. These primitive surfaces are special cases of 3-D quadric surfaces. Primitive surface estimation is treated as the general problem of maximum likelihood parameter estimation based on two or more functionally related data sets. In the present case, these data sets constitute a sequence of images taken at different locations and orientations. A simple geometric explanation is given for the estimation algorithm. Though various techniques can be used to implement this nonlinear estimation, researches discuss the use of gradient descent. Experiments are run and discussed for the case of a sphere of unknown location. These experiments graphically illustrate the various advantages of using as many images as possible in the estimation and of distributing camera positions from first to last over as large a baseline as possible. Researchers introduce the use of asymptotic Bayesian approximations in order to summarize the useful information in a sequence of images, thereby drastically reducing both the storage and amount of processing required.

  9. Holographic measurement of wall stress distribution and 3D flow over a surface textured by microfibers

    NASA Astrophysics Data System (ADS)

    Bocanegra, Humberto; Gorumlu, Seder; Aksak, Burak; Castillo, Luciano; Sheng, Jian

    2015-11-01

    Understanding how fluid flow interacts with micro-textured surfaces is crucial for a broad range of key biological processes and engineering applications including particle dispersion, pathogenic infections, and drag manipulation by surface topology. Existing methods, such as μPIV, suffers from low spatial resolution and fail to track tracer particle motion very close to a rough surface and within roughness elements. In this paper, we present a technique that combines high speed digital holographic microscopy (DHM) with a correlation based de-noising algorithm to overcome the optical interference generated by surface roughness and to capture a large number of 3D particle trajectories. It allows us to obtain a 3D velocity field with an uncertainty of 0.01% and 2D wall shear stress distribution at the resolution of ~ 65 μPa. Applying the technique to a microfluidics with a surface textured by microfibers, we find that the flow is three-dimensional and complex. While the microfibers affect the velocity flow field locally, their presence is felt globally in terms of wall shear stresses. The study of effect of microfiber patterns and flow characteristics on skin frictions are ongoing and will be reported.

  10. Damage and deterioration monitoring of artwork by data fusion of 3D surface and hyperspectral measurements

    NASA Astrophysics Data System (ADS)

    Groves, Roger M.; Caballero, José; Quinzan, Ianisse; Ribes-Gómez, Emilio

    2014-05-01

    This paper describes the processing algorithm methodology and preliminary results from a novel optical-based system for the assessment of chemical and mechanical deterioration of artworks. The FP7 Syddarta Project prototype is composed of two optical channels: 1) a 3D imaging channel which acquires 3D surface data and multiband information in the visible spectral range; 2) an infrared hyperspectral imaging channel in the spectral range 900 to 2500 nm. The processing algorithms developed perform the system calibration, damage detection and chemical deterioration analysis. Both photometric and geometric calibrations have been implemented. The photometric calibration is based on a white reference and intensity map and compensates for variation in light intensities. The geometric calibration is based on planar homographies to determine the interior and exterior orientation of the projector and the two cameras. This is used to map the acquired data of the different sensors into a single reference frame. To acquire 3D data, a set of phase-shifted fringe patterns is projected on the object which are processed by Fourier transform. To identify mechanical deterioration, the acquired 3D cloud of points is meshed and differences in surface normals for a given radius are computed. To analyse the chemical deterioration of the pigments a supervised classification method has been implemented. First of all, spectral data is normalized with the Extended Multiplicative Scatter Correction algorithm. Then, data dimensionality is reduced by applying Principal Component Analysis and classification is done with Support Vector Machine. Results are presented showing the performance of the described algorithms.

  11. A 3D-CFD code for accurate prediction of fluid flows and fluid forces in seals

    NASA Astrophysics Data System (ADS)

    Athavale, M. M.; Przekwas, A. J.; Hendricks, R. C.

    1994-01-01

    Current and future turbomachinery requires advanced seal configurations to control leakage, inhibit mixing of incompatible fluids and to control the rotodynamic response. In recognition of a deficiency in the existing predictive methodology for seals, a seven year effort was established in 1990 by NASA's Office of Aeronautics Exploration and Technology, under the Earth-to-Orbit Propulsion program, to develop validated Computational Fluid Dynamics (CFD) concepts, codes and analyses for seals. The effort will provide NASA and the U.S. Aerospace Industry with advanced CFD scientific codes and industrial codes for analyzing and designing turbomachinery seals. An advanced 3D CFD cylindrical seal code has been developed, incorporating state-of-the-art computational methodology for flow analysis in straight, tapered and stepped seals. Relevant computational features of the code include: stationary/rotating coordinates, cylindrical and general Body Fitted Coordinates (BFC) systems, high order differencing schemes, colocated variable arrangement, advanced turbulence models, incompressible/compressible flows, and moving grids. This paper presents the current status of code development, code demonstration for predicting rotordynamic coefficients, numerical parametric study of entrance loss coefficients for generic annular seals, and plans for code extensions to labyrinth, damping, and other seal configurations.

  12. 3D parameter to quantify the anisotropy measurement of periodic structures on rough surfaces.

    PubMed

    Guillemot, G; Bigerelle, M; Khawaja, Z

    2014-01-01

    In this paper, a new 3D roughness parameter, Sreg, is proposed to quantify the regularity of a surface, independent of the amplitude and the scanning length units of the surface. The efficiency of this parameter is tested on noisy periodical surfaces with degrees of anisotropy. This parameter lies between zero (perfect noise) and 100% (a perfect periodic surface). This parameter enables the identification of the anisotropy directions of regularity for a given surface. For a periodical surface, the greater the noise, the lower the anisotropy. A direction function is proposed to analyse the direction of regularity of a rough surface, which then permits characterization of the directional regularity of the topography. The regularity parameter can be used for several purposes: to identify the direction of periodical structures formed by laser-pulsed radiations on the surface of solid workpieces; to examine the reproducibility of surface machining methods such as finishing process; and to identify the surface regularity produced by abrasive machining, such as precision surface grain, abrasive slotting, and lapping. PMID:23824916

  13. Determination of 3D Surface Roughness Parameters by Cross-Section Method

    NASA Astrophysics Data System (ADS)

    Rudzitis, J.; Krizbergs, J.; Kumermanis, M.; Mozga, N.; Ancans, A.; Leitans, A.

    2014-04-01

    Currently, in the production engineering the surface roughness parameters are estimated in three dimensions, however, the equipment for these measurements is rather expensive and not always available. In many cases to buy such equipment is not economically justified. Therefore, the 3D surface roughness parameters are usually determined from the well-known 2D profile ones using the existing 2D equipment. This could be done best using the cross-section (or profile) method, especially in the case of nanoroughness estimation, with calculation of the mean values for the roughness height, spacing, and shape. This method - though mainly meant for irregular rough surfaces - can also be used for other types of rough surfaces. Particular emphasis is here given to the correlation between the surface cross-section (profile) parameters and 3D parameters as well as to the choice of the number of cross-cuttings and their orientation on the surface. Mūsdienu ražošanā ir nepieciešams novērtēt virsmas raupjuma parametrus trijās dimensijās, tomēr, aprīkojums šādu mērījumu veikšanai ir ļoti dārgs un ne vienmēr pieejams. Tādēļ bieži rodas nepieciešamība noteikt 3D virsmas raupjuma parametrus pēc labi zināmajiem profila (2D) parametriem, izmantojot eksistējošo 2D mērīšanas aprīkojumu. Labākais risinājums šai problēmai ir izmantot 3D raupjuma parametru noteikšanai šķēlumu jeb profilu metodi. Metode uzrāda labus rezultātus arī novērtējot nanoraupjumu. Iespējams aprēķināt sekojošu virsmas raupjuma mikrotopogrāfisko parametru vidējās vērtības: raupjuma augstumu; soļu parametrus un formu. Metode ir paredzēta izmantošanai virsmām ar neregulāru raksturu, bet var tikt pielāgota arī citu tipu virsmām.

  14. 3-D Measurement and Visualization of Electrical Propagation on Heart Surface

    NASA Astrophysics Data System (ADS)

    Lin, Shien-Fong; Wikswo, John P.

    1997-11-01

    Optical recording of the cardiac transmembrane potential (Vm) has recently become a powerful tool to reveal patterns of electrical wave front dynamics on the heart surface. The optical mapping techniques have been previously applied to observe a portion of the heart due to its 3-D geometry. We extended our 2-D optical mapping technique to include one front view and two back mirror views for measuring and visualizing the transmembrane potential distribution simultaneously over entire surface of an isolated rabbit heart. The heart was illuminated with an argon laser delivered through an optical fiber bundle consisting of seven 1-mm fibers. These fibers were positioned around the heart to induce a near-uniform fluorescence intensity distribution on the heart surface. A single high-speed CCD camera with a long depth of field recorded the laser-stimulated epifluorescence from all three views in a single frame. Sequences of 100 to 600 frames of 12-bit/pixel digital images were recorded during regular pacing or induced ventricular fibrillation at 335 frames/second. Image processing then yielded the Vm distribution at a resolution of 128x64 pixels/frame. The propagating wave front images were obtained by subtracting two subsequent Vm images. The geometry of the heart was obtained by profilometry. The wave front information obtained from image processing could be texture-mapped to the heart geometry for visualization. Our 3-D imaging technique provides simultaneous, dynamic information of wave front activation and propagation over entire heart surface, and thereby can offer a more complete knowledge of wave front dynamics in a whole heart model. Future work involves automatic procedure for digitizing the heart shape and measuring the wave front dimensions using the 3-D geometry.

  15. How to select the most relevant 3D roughness parameters of a surface.

    PubMed

    Deltombe, R; Kubiak, K J; Bigerelle, M

    2014-01-01

    In order to conduct a comprehensive roughness analysis, around sixty 3D roughness parameters are created to describe most of the surface morphology with regard to specific functions, properties or applications. In this paper, a multiscale surface topography decomposition method is proposed with application to stainless steel (AISI 304), which is processed by rolling at different fabrication stages and by electrical discharge tool machining. Fifty-six 3D-roughness parameters defined in ISO, EUR, and ASME standards are calculated for the measured surfaces. Then, expert software "MesRug" is employed to perform statistical analysis on acquired data in order to find the most relevant parameters characterizing the effect of both processes (rolling and machining), and to determine the most appropriate scale of analysis. For the rolling process: The parameter Vmc (the Core Material Volume--defined as volume of material comprising the texture between heights corresponding to the material ratio values of p = 10% and q = 80%) computed at the scale of 3 µm is the most relevant parameter to characterize the cold rolling process. For the EDM Process, the best roughness parameter is SPD that represents the number of peaks per unit area after segmentation of a surface into motifs computed at the scale of 8 µm. PMID:24038147

  16. Diaphragm dome surface segmentation in CT data sets: a 3D active appearance model approach

    NASA Astrophysics Data System (ADS)

    Beichel, Reinhard; Gotschuli, Georg; Sorantin, Erich; Leberl, Franz W.; Sonka, Milan

    2002-05-01

    Knowledge about the location of the diaphragm dome surface, which separates the lungs and the heart from the abdominal cavity, is of vital importance for applications like automated segmentation of adjacent organs (e.g., liver) or functional analysis of the respiratory cycle. We present a new 3D Active Appearance Model (AAM) approach to segmentation of the top layer of the diaphragm dome. The 3D AAM consists of three parts: a 2D closed curve (reference curve), an elevation image and texture layers. The first two parts combined represent 3D shape information and the third part image intensity of the diaphragm dome and the surrounding layers. Differences in height between dome voxels and a reference plane are stored in the elevation image. The reference curve is generated by a parallel projection of the diaphragm dome outline in the axial direction. Landmark point placement is only done on the (2D) reference curve, which can be seen as the bounding curve of the elevation image. Matching is based on a gradient-descent optimization process and uses image intensity appearance around the actual dome shape. Results achieved in 60 computer generated phantom data sets show a high degree of accuracy (positioning error -0.07+/-1.29 mm). Validation using real CT data sets yielded a positioning error of -0.16+/-2.95 mm. Additional training and testing on in-vivo CT image data is ongoing.

  17. Leaf Area Index Estimation in Vineyards from Uav Hyperspectral Data, 2d Image Mosaics and 3d Canopy Surface Models

    NASA Astrophysics Data System (ADS)

    Kalisperakis, I.; Stentoumis, Ch.; Grammatikopoulos, L.; Karantzalos, K.

    2015-08-01

    The indirect estimation of leaf area index (LAI) in large spatial scales is crucial for several environmental and agricultural applications. To this end, in this paper, we compare and evaluate LAI estimation in vineyards from different UAV imaging datasets. In particular, canopy levels were estimated from i.e., (i) hyperspectral data, (ii) 2D RGB orthophotomosaics and (iii) 3D crop surface models. The computed canopy levels have been used to establish relationships with the measured LAI (ground truth) from several vines in Nemea, Greece. The overall evaluation indicated that the estimated canopy levels were correlated (r2 > 73%) with the in-situ, ground truth LAI measurements. As expected the lowest correlations were derived from the calculated greenness levels from the 2D RGB orthomosaics. The highest correlation rates were established with the hyperspectral canopy greenness and the 3D canopy surface models. For the later the accurate detection of canopy, soil and other materials in between the vine rows is required. All approaches tend to overestimate LAI in cases with sparse, weak, unhealthy plants and canopy.

  18. TRAIL protein localization in human primary T cells by 3D microscopy using 3D interactive surface plot: a new method to visualize plasma membrane.

    PubMed

    Gras, Christophe; Smith, Nikaïa; Sengmanivong, Lucie; Gandini, Mariana; Kubelka, Claire Fernandes; Herbeuval, Jean-Philippe

    2013-01-31

    The apoptotic ligand TNF-related apoptosis ligand (TRAIL) is expressed on the membrane of immune cells during HIV infection. The intracellular stockade of TRAIL in human primary CD4(+) T cells is not known. Here we investigated whether primary CD4(+) T cells expressed TRAIL in their intracellular compartment and whether TRAIL is relocalized on the plasma membrane under HIV activation. We found that TRAIL protein was stocked in intracellular compartment in non activated CD4(+) T cells and that the total level of TRAIL protein was not increased under HIV-1 stimulation. However, TRAIL was massively relocalized on plasma membrane when cells were cultured with HIV. Using three dimensional (3D) microscopy we localized TRAIL protein in human T cells and developed a new method to visualize plasma membrane without the need of a membrane marker. This method used the 3D interactive surface plot and bright light acquired images. PMID:23085529

  19. Additive manufactured polymeric 3D scaffolds with tailored surface topography influence mesenchymal stromal cells activity.

    PubMed

    Neves, Sara C; Mota, Carlos; Longoni, Alessia; Barrias, Cristina C; Granja, Pedro L; Moroni, Lorenzo

    2016-06-01

    Additive manufactured three-dimensional (3D) scaffolds with tailored surface topography constitute a clear advantage in tissue regeneration strategies to steer cell behavior. 3D fibrous scaffolds of poly(ethylene oxide terephthalate)/poly(butylene terephthalate) block copolymer presenting different fiber surface features were successfully fabricated by additive manufacturing combined with wet-spinning, in a single step, without any post-processing. The optimization of the processing parameters, mainly driven by different solvent/non-solvent combinations, led to four distinct scaffold types, with average surface roughness values ranging from 0.071 ± 0.012 μm to 1.950 ± 0.553 μm, average pore sizes in the x- and y-axis between 351.1 ± 33.6 μm and 396.1 ± 32.3 μm, in the z-axis between 36.5 ± 5.3 μm and 70.7 ± 8.8 μm, average fiber diameters between 69.4 ± 6.1 μm and 99.0 ± 9.4 μm, and porosity values ranging from 60.2 ± 0.8% to 71.7 ± 2.6%. Human mesenchymal stromal cells (hMSCs) cultured on these scaffolds adhered, proliferated, and produced endogenous extracellular matrix. The effect of surface roughness and topography on hMSCs differentiation was more evident for cells seeded at lower density, where the percentage of cells in direct contact with the surface was higher compared to more densely seeded scaffolds. Under osteogenic conditions, lower surface roughness values (0.227 ± 0.035 μm) had a synergistic effect on hMSCs behavior, while chondrogenesis was favored on rougher surfaces (1.950 ± 0.553 μm). PMID:27219645

  20. Anomalous surface segregation behaviour of some 3d elements in ferromagnetic iron.

    PubMed

    Gupta, Michèle; Gupta, Raju P

    2013-10-16

    The segregation of Cr in Fe is known to be anomalous since the barrier for surface segregation of Cr is not determined by the topmost surface layer, as one would expect, but rather by the subsurface layer where the energy of segregation is much larger and endothermic. This has been attributed to a complex interaction involving the antiferromagnetism of Cr and the ferromagnetism of Fe. We report in this paper the results of our ab initio electronic structure calculations on the segregation behaviour of all the 3d elements on the (1 0 0) surface of ferromagnetic iron in the hope of better understanding this phenomenon. We find a similar behaviour for the segregation of the next antiferromagnetic 3d element Mn in Fe, where the subsurface layer is also found to block the segregation of Mn to the surface. On the other hand, ferromagnetic Co exhibits a normal segregation behaviour. The elements Sc, Cu and Ni do not form solid solutions with ferromagnetic iron. The early elements Ti and V are non-magnetic in their metallic states, but are strongly polarized by Fe, and develop magnetic moments which are aligned antiferromagnetically to those of Fe atoms. While the subsurface layer blocks the segregation of Ti to the surface, no blocking behaviour is found for the segregation of V. The segregation behaviour of all these elements is strongly correlated with the displacement of the solute atoms on the surface of Fe. The elements showing anomalous segregation behaviour are all displaced upwards on the surface, while those showing normal segregation are pulled inwards. These results indicate that the antiferromagnetism of the segregating element plays the key role in the anomalous segregation behaviour in Fe. PMID:24047767

  1. Accurate high-resolution measurements of 3-D tissue dynamics with registration-enhanced displacement encoded MRI.

    PubMed

    Gomez, Arnold D; Merchant, Samer S; Hsu, Edward W

    2014-06-01

    Displacement fields are important to analyze deformation, which is associated with functional and material tissue properties often used as indicators of health. Magnetic resonance imaging (MRI) techniques like DENSE and image registration methods like Hyperelastic Warping have been used to produce pixel-level deformation fields that are desirable in high-resolution analysis. However, DENSE can be complicated by challenges associated with image phase unwrapping, in particular offset determination. On the other hand, Hyperelastic Warping can be hampered by low local image contrast. The current work proposes a novel approach for measuring tissue displacement with both DENSE and Hyperelastic Warping, incorporating physically accurate displacements obtained by the latter to improve phase characterization in DENSE. The validity of the proposed technique is demonstrated using numerical and physical phantoms, and in vivo small animal cardiac MRI. PMID:24771572

  2. Accurate High-Resolution Measurements of 3-D Tissue Dynamics With Registration-Enhanced Displacement Encoded MRI

    PubMed Central

    Merchant, Samer S.; Hsu, Edward W.

    2014-01-01

    Displacement fields are important to analyze deformation, which is associated with functional and material tissue properties often used as indicators of health. Magnetic resonance imaging (MRI) techniques like DENSE and image registration methods like Hyperelastic Warping have been used to produce pixel-level deformation fields that are desirable in high-resolution analysis. However, DENSE can be complicated by challenges associated with image phase unwrapping, in particular offset determination. On the other hand, Hyperelastic Warping can be hampered by low local image contrast. The current work proposes a novel approach for measuring tissue displacement with both DENSE and Hyperelastic Warping, incorporating physically accurate displacements obtained by the latter to improve phase characterization in DENSE. The validity of the proposed technique is demonstrated using numerical and physical phantoms, and in vivo small animal cardiac MRI. PMID:24771572

  3. Performance analysis of different surface reconstruction algorithms for 3D reconstruction of outdoor objects from their digital images.

    PubMed

    Maiti, Abhik; Chakravarty, Debashish

    2016-01-01

    3D reconstruction of geo-objects from their digital images is a time-efficient and convenient way of studying the structural features of the object being modelled. This paper presents a 3D reconstruction methodology which can be used to generate photo-realistic 3D watertight surface of different irregular shaped objects, from digital image sequences of the objects. The 3D reconstruction approach described here is robust, simplistic and can be readily used in reconstructing watertight 3D surface of any object from its digital image sequence. Here, digital images of different objects are used to build sparse, followed by dense 3D point clouds of the objects. These image-obtained point clouds are then used for generation of photo-realistic 3D surfaces, using different surface reconstruction algorithms such as Poisson reconstruction and Ball-pivoting algorithm. Different control parameters of these algorithms are identified, which affect the quality and computation time of the reconstructed 3D surface. The effects of these control parameters in generation of 3D surface from point clouds of different density are studied. It is shown that the reconstructed surface quality of Poisson reconstruction depends on Samples per node (SN) significantly, greater SN values resulting in better quality surfaces. Also, the quality of the 3D surface generated using Ball-Pivoting algorithm is found to be highly depend upon Clustering radius and Angle threshold values. The results obtained from this study give the readers of the article a valuable insight into the effects of different control parameters on determining the reconstructed surface quality. PMID:27386376

  4. Surface-effect corrections for solar-like oscillations using 3D hydrodynamical simulations. I. Adiabatic oscillations

    NASA Astrophysics Data System (ADS)

    Sonoi, T.; Samadi, R.; Belkacem, K.; Ludwig, H.-G.; Caffau, E.; Mosser, B.

    2015-11-01

    Context. The CoRoT and Kepler space-borne missions have provided us with a wealth of high-quality observational data that allows for seismic inferences of stellar interiors. This requires the computation of precise and accurate theoretical frequencies, but imperfect modeling of the uppermost stellar layers introduces systematic errors. To overcome this problem, an empirical correction has been introduced by Kjeldsen et al. (2008, ApJ, 683, L175) and is now commonly used for seismic inferences. Nevertheless, we still lack a physical justification allowing for the quantification of the surface-effect corrections. Aims: Our aim is to constrain the surface-effect corrections across the Hertzsprung-Russell (HR) diagram using a set of 3D hydrodynamical simulations. Methods: We used a grid of these simulations computed with the CO5BOLD code to model the outer layers of solar-like stars. Upper layers of the corresponding 1D standard models were then replaced by the layers obtained from the horizontally averaged 3D models. The frequency differences between these patched models and the 1D standard models were then calculated using the adiabatic approximation and allowed us to constrain the Kjeldsen et al. power law, as well as a Lorentzian formulation. Results: We find that the surface effects on modal frequencies depend significantly on both the effective temperature and the surface gravity. We further provide the variation in the parameters related to the surface-effect corrections using their power law as well as a Lorentzian formulation. Scaling relations between these parameters and the elevation (related to the Mach number) is also provided. The Lorentzian formulation is shown to be more robust for the whole frequency spectrum, while the power law is not suitable for the frequency shifts in the frequency range above νmax. Finally, we show that, owing to turbulent pressure, the elevation of the uppermost layers modifies the location of the hydrogen ionization zone and

  5. Shot noise limit of the optical 3D measurement methods for smooth surfaces

    NASA Astrophysics Data System (ADS)

    Pavliček, Pavel; Pech, Miroslav

    2016-03-01

    The measurement uncertainty of optical 3D measurement methods for smooth surfaces caused by shot noise is investigated. The shot noise is a fundamental property of the quantum nature of light. If all noise sources are eliminated, the shot noise represents the ultimate limit of the measurement uncertainty. The measurement uncertainty is calculated for several simple model methods. The analysis shows that the measurement uncertainty depends on the wavelength of used light, the number of photons used for the measurement, and on a factor that is connected with the geometric arrangement of the measurement setup.

  6. Extended volume and surface scatterometer for optical characterization of 3D-printed elements

    NASA Astrophysics Data System (ADS)

    Dannenberg, Florian; Uebeler, Denise; Weiß, Jürgen; Pescoller, Lukas; Weyer, Cornelia; Hahlweg, Cornelius

    2015-09-01

    The use of 3d printing technology seems to be a promising way for low cost prototyping, not only of mechanical, but also of optical components or systems. It is especially useful in applications where customized equipment repeatedly is subject to immediate destruction, as in experimental detonics and the like. Due to the nature of the 3D-printing process, there is a certain inner texture and therefore inhomogeneous optical behaviour to be taken into account, which also indicates mechanical anisotropy. Recent investigations are dedicated to quantification of optical properties of such printed bodies and derivation of corresponding optimization strategies for the printing process. Beside mounting, alignment and illumination means, also refractive and reflective elements are subject to investigation. The proposed measurement methods are based on an imaging nearfield scatterometer for combined volume and surface scatter measurements as proposed in previous papers. In continuation of last year's paper on the use of near field imaging, which basically is a reflective shadowgraph method, for characterization of glossy surfaces like printed matter or laminated material, further developments are discussed. The device has been extended for observation of photoelasticity effects and therefore homogeneity of polarization behaviour. A refined experimental set-up is introduced. Variation of plane of focus and incident angle are used for separation of various the images of the layers of the surface under test, cross and parallel polarization techniques are applied. Practical examples from current research studies are included.

  7. 3D surface reconstruction and FIB microscopy of worn alumina hip prostheses

    NASA Astrophysics Data System (ADS)

    Zeng, P.; Inkson, B. J.; Rainforth, W. M.; Stewart, T.

    2008-08-01

    Interest in alumina-on-alumina total hip replacements (THR) continues to grow for the young and active patient due to their superior wear performance and biocompatibility compared to the alternative traditional polymer/metal prostheses. While alumina on alumina bearings offer an excellent solution, a region of high wear, known as stripe wear, is commonly observed on retrieved alumina hip components that poses concern. These in-vivo stripe wear mechanisms can be replicated in vitro by the introduction of micro-separation during the simulated walking cycle in hip joint simulation. However, the understanding of the mechanisms behind the stripe wear processes is relatively poor. 3D topographic reconstructions of titled SEM stereo pairs from different zones have been obtained to determine the local worn surface topography. Focused ion beam (FIB) microscopy was applied to examine the subsurface damage across the stripe wear. The paper presents novel images of sub-surface microcracks in alumina along with 3D reconstructions of the worn ceramic surfaces and a classification of four distinct wear zones following microseparation in hip prostheses.

  8. Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices.

    PubMed

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Kühmstedt, Peter; Notni, Gunther

    2015-01-01

    In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given. PMID:26703624

  9. Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices

    PubMed Central

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Kühmstedt, Peter; Notni, Gunther

    2015-01-01

    In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given. PMID:26703624

  10. Measuring surface topography with scanning electron microscopy. I. EZEImage: a program to obtain 3D surface data.

    PubMed

    Ponz, Ezequiel; Ladaga, Juan Luis; Bonetto, Rita Dominga

    2006-04-01

    Scanning electron microscopy (SEM) is widely used in the science of materials and different parameters were developed to characterize the surface roughness. In a previous work, we studied the surface topography with fractal dimension at low scale and two parameters at high scale by using the variogram, that is, variance vs. step log-log graph, of a SEM image. Those studies were carried out with the FERImage program, previously developed by us. To verify the previously accepted hypothesis by working with only an image, it is indispensable to have reliable three-dimensional (3D) surface data. In this work, a new program (EZEImage) to characterize 3D surface topography in SEM has been developed. It uses fast cross correlation and dynamic programming to obtain reliable dense height maps in a few seconds which can be displayed as an image where each gray level represents a height value. This image can be used for the FERImage program or any other software to obtain surface topography characteristics. EZEImage also generates anaglyph images as well as characterizes 3D surface topography by means of a parameter set to describe amplitude properties and three functional indices for characterizing bearing and fluid properties. PMID:17481354

  11. Density functional study of hydrazine N-N bond cleaving on 3d metal surfaces

    NASA Astrophysics Data System (ADS)

    Fathurrahman, Fadjar; Kasai, Hideaki

    2015-11-01

    Theoretical calculations based on dispersion-corrected density functional theory (DFT-D2) has been performed to investigate hydrazine adsorption and N-N bond cleaving on closed packed surfaces of 3d metals: Fe(110), Co(0001), Ni(111), Cu(111), and Zn(0001). The activation energies of N-N bond cleaving of hydrazine on each surface are estimated using climbing-image nudged elastic band (CINEB) method. The results showed that the activation energies for this process have increasing trend from Fe(110) to Zn(0001). By examining the electronic structure of the adsorbed hydrazine, it is found that this trend is related to occupation of derived 6σ* orbitals. It is also found that approximate linear relationship between reaction energy and activation energy (the Brønsted-Evans-Polanyi (BEP) relationship) holds for those surfaces.

  12. Effect of a 3D surface depression on boundary layer transition

    NASA Astrophysics Data System (ADS)

    Xu, Hui; Mughal, Shahid; Sherwin, Spencer J.

    2015-11-01

    The influence of a three-dimensional surface depression on the transitional boundary layer is investigated numerically. In the boundary layer transition, the primary mode is a Tollmien-Schlichting (TS) wave which is a viscous instability. These modes are receptive to surface roughness interacting with free stream disturbances and/or surface vibrations. In this paper, numerical calculations are carried out to investigate the effect of the depression on instability of the boundary layer. In order to implement linear analysis, two/three (2D/3D)-dimensional nonlinear Navier-Stokes equations are solved by spectral element method to generate base flows in a sufficient large domain. The linear analyses are done by the parabolic stability equations (PSE). Finally, a DNS calculation is done to simulate the boundary layer transition.

  13. Preliminary study of surface modification of 3D Poly (ɛ - caprolactone) scaffolds by ultrashort laser irradiation

    NASA Astrophysics Data System (ADS)

    Daskalova, A.; Bliznakova, I.; Iordanova, E.; Yankov, G.; Grozeva, M.; Ostrowska, B.

    2016-02-01

    Three - dimensional poly (e- caprolactone) (PCL) scaffolds as suitable biocompatible material for manufacturing tissue replacements are utilized for tissue engineering purposes. The porous structures are fabricated by rapid prototyping method (Bioscaffolder) based on hypodermic dispensing process. The consecution of experiments demonstrated the possibility on creation of surface micro formations, applying different laser fluences, at 1 kHz repetition rate for fixed time of exposure 1 sec at 800 nm central wavelength. The combination of both methods offers possibilities for successful production of 3D matrices with modified surfaces. The obtained results of laser - induced surface modifications of PCL demonstrate the potential of the method to microprocess this kind of material for possible applications in regenerative medicine.

  14. Focus Variation - A New Technology for High Resolution Optical 3D Surface Metrology in the Micro- and Nanometer Range

    NASA Astrophysics Data System (ADS)

    Huber, O.

    2009-04-01

    3D measurement device simultaneously captures the entire surface topographic information in combination with its true color information. Both the topographic and color information are registered to the 3D data file. The system is capable to handle a large amount of data and can be used for industrial quality assurance as well as research and development activities. The key applications of the system are: - Surface analysis - Characterization of tools (particularly crucial parameters such as radii and angles) and all kinds of scientific materials - Failure analysis - Investigation of corrosion and tribology (cause, influence, effects) - Variance and wear analysis Compared to tactile instruments, the technique of Focus-Variation offers several advantages from which the performance of the geo-instruments benefits. Since the optical technique is an area-based one, a much larger amount of data is obtained from a single measurement, leading to more accurate results. Also, measurements are non destructive and wearless.

  15. Estimation of Atmospheric Methane Surface Fluxes Using a Global 3-D Chemical Transport Model

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Prinn, R.

    2003-12-01

    Accurate determination of atmospheric methane surface fluxes is an important and challenging problem in global biogeochemical cycles. We use inverse modeling to estimate annual, seasonal, and interannual CH4 fluxes between 1996 and 2001. The fluxes include 7 time-varying seasonal (3 wetland, rice, and 3 biomass burning) and 3 steady aseasonal (animals/waste, coal, and gas) global processes. To simulate atmospheric methane, we use the 3-D chemical transport model MATCH driven by NCEP reanalyzed observed winds at a resolution of T42 ( ˜2.8° x 2.8° ) in the horizontal and 28 levels (1000 - 3 mb) in the vertical. By combining existing datasets of individual processes, we construct a reference emissions field that represents our prior guess of the total CH4 surface flux. For the methane sink, we use a prescribed, annually-repeating OH field scaled to fit methyl chloroform observations. MATCH is used to produce both the reference run from the reference emissions, and the time-dependent sensitivities that relate individual emission processes to observations. The observational data include CH4 time-series from ˜15 high-frequency (in-situ) and ˜50 low-frequency (flask) observing sites. Most of the high-frequency data, at a time resolution of 40-60 minutes, have not previously been used in global scale inversions. In the inversion, the high-frequency data generally have greater weight than the weekly flask data because they better define the observational monthly means. The Kalman Filter is used as the optimal inversion technique to solve for emissions between 1996-2001. At each step in the inversion, new monthly observations are utilized and new emissions estimates are produced. The optimized emissions represent deviations from the reference emissions that lead to a better fit to the observations. The seasonal processes are optimized for each month, and contain the methane seasonality and interannual variability. The aseasonal processes, which are less variable, are

  16. Persistent and automatic intraoperative 3D digitization of surfaces under dynamic magnifications of an operating microscope

    PubMed Central

    Kumar, Ankur N.; Miga, Michael I.; Pheiffer, Thomas S.; Chambless, Lola B.; Thompson, Reid C.; Dawant, Benoit M.

    2014-01-01

    One of the major challenges impeding advancement in image-guided surgical (IGS) systems is the soft-tissue deformation during surgical procedures. These deformations reduce the utility of the patient’s preoperative images and may produce inaccuracies in the application of preoperative surgical plans. Solutions to compensate for the tissue deformations include the acquisition of intraoperative tomographic images of the whole organ for direct displacement measurement and techniques that combines intraoperative organ surface measurements with computational biomechanical models to predict subsurface displacements. The later solution has the advantage of being less expensive and amenable to surgical workflow. Several modalities such as textured laser scanners, conoscopic holography, and stereo-pair cameras have been proposed for the intraoperative 3D estimation of organ surfaces to drive patient-specific biomechanical models for the intraoperative update of preoperative images. Though each modality has its respective advantages and disadvantages, stereo-pair camera approaches used within a standard operating microscope is the focus of this article. A new method that permits the automatic and near real-time estimation of 3D surfaces (at 1Hz) under varying magnifications of the operating microscope is proposed. This method has been evaluated on a CAD phantom object and on full-length neurosurgery video sequences (~1 hour) acquired intraoperatively by the proposed stereovision system. To the best of our knowledge, this type of validation study on full-length brain tumor surgery videos has not been done before. The method for estimating the unknown magnification factor of the operating microscope achieves accuracy within 0.02 of the theoretical value on a CAD phantom and within 0.06 on 4 clinical videos of the entire brain tumor surgery. When compared to a laser range scanner, the proposed method for reconstructing 3D surfaces intraoperatively achieves root mean square

  17. Persistent and automatic intraoperative 3D digitization of surfaces under dynamic magnifications of an operating microscope.

    PubMed

    Kumar, Ankur N; Miga, Michael I; Pheiffer, Thomas S; Chambless, Lola B; Thompson, Reid C; Dawant, Benoit M

    2015-01-01

    One of the major challenges impeding advancement in image-guided surgical (IGS) systems is the soft-tissue deformation during surgical procedures. These deformations reduce the utility of the patient's preoperative images and may produce inaccuracies in the application of preoperative surgical plans. Solutions to compensate for the tissue deformations include the acquisition of intraoperative tomographic images of the whole organ for direct displacement measurement and techniques that combines intraoperative organ surface measurements with computational biomechanical models to predict subsurface displacements. The later solution has the advantage of being less expensive and amenable to surgical workflow. Several modalities such as textured laser scanners, conoscopic holography, and stereo-pair cameras have been proposed for the intraoperative 3D estimation of organ surfaces to drive patient-specific biomechanical models for the intraoperative update of preoperative images. Though each modality has its respective advantages and disadvantages, stereo-pair camera approaches used within a standard operating microscope is the focus of this article. A new method that permits the automatic and near real-time estimation of 3D surfaces (at 1 Hz) under varying magnifications of the operating microscope is proposed. This method has been evaluated on a CAD phantom object and on full-length neurosurgery video sequences (∼1 h) acquired intraoperatively by the proposed stereovision system. To the best of our knowledge, this type of validation study on full-length brain tumor surgery videos has not been done before. The method for estimating the unknown magnification factor of the operating microscope achieves accuracy within 0.02 of the theoretical value on a CAD phantom and within 0.06 on 4 clinical videos of the entire brain tumor surgery. When compared to a laser range scanner, the proposed method for reconstructing 3D surfaces intraoperatively achieves root mean square

  18. Empirical assessment of the validity limits of the surface wave full ray theory using realistic 3-D Earth models

    NASA Astrophysics Data System (ADS)

    Parisi, Laura; Ferreira, Ana M. G.

    2016-04-01

    The surface wave full ray theory (FRT) is an efficient tool to calculate synthetic waveforms of surface waves. It combines the concept of local modes with exact ray tracing as a function of frequency, providing a more complete description of surface wave propagation than the widely used great circle approximation (GCA). The purpose of this study is to evaluate the ability of the FRT approach to model teleseismic long-period surface waveforms (T ˜ 45-150 s) in the context of current 3-D Earth models to empirically assess its validity domain and its scope for future studies in seismic tomography. To achieve this goal, we compute vertical and horizontal component fundamental mode synthetic Rayleigh waveforms using the FRT, which are compared with calculations using the highly accurate spectral element method. We use 13 global earth models including 3-D crustal and mantle structure, which are derived by successively varying the strength and lengthscale of heterogeneity in current tomographic models. For completeness, GCA waveforms are also compared with the spectral element method. We find that the FRT accurately predicts the phase and amplitude of long-period Rayleigh waves (T ˜ 45-150 s) for almost all the models considered, with errors in the modelling of the phase (amplitude) of Rayleigh waves being smaller than 5 per cent (10 per cent) in most cases. The largest errors in phase and amplitude are observed for T ˜ 45 s and for the three roughest earth models considered that exhibit shear wave anomalies of up to ˜20 per cent, which is much larger than in current global tomographic models. In addition, we find that overall the GCA does not predict Rayleigh wave amplitudes well, except for the longest wave periods (T ˜ 150 s) and the smoothest models considered. Although the GCA accurately predicts Rayleigh wave phase for current earth models such as S20RTS and S40RTS, FRT's phase errors are smaller, notably for the shortest wave periods considered (T ˜ 45 s and

  19. On the Use of Uavs in Mining and Archaeology - Geo-Accurate 3d Reconstructions Using Various Platforms and Terrestrial Views

    NASA Astrophysics Data System (ADS)

    Tscharf, A.; Rumpler, M.; Fraundorfer, F.; Mayer, G.; Bischof, H.

    2015-08-01

    During the last decades photogrammetric computer vision systems have been well established in scientific and commercial applications. Especially the increasing affordability of unmanned aerial vehicles (UAVs) in conjunction with automated multi-view processing pipelines have resulted in an easy way of acquiring spatial data and creating realistic and accurate 3D models. With the use of multicopter UAVs, it is possible to record highly overlapping images from almost terrestrial camera positions to oblique and nadir aerial images due to the ability to navigate slowly, hover and capture images at nearly any possible position. Multi-copter UAVs thus are bridging the gap between terrestrial and traditional aerial image acquisition and are therefore ideally suited to enable easy and safe data collection and inspection tasks in complex or hazardous environments. In this paper we present a fully automated processing pipeline for precise, metric and geo-accurate 3D reconstructions of complex geometries using various imaging platforms. Our workflow allows for georeferencing of UAV imagery based on GPS-measurements of camera stations from an on-board GPS receiver as well as tie and control point information. Ground control points (GCPs) are integrated directly in the bundle adjustment to refine the georegistration and correct for systematic distortions of the image block. We discuss our approach based on three different case studies for applications in mining and archaeology and present several accuracy related analyses investigating georegistration, camera network configuration and ground sampling distance. Our approach is furthermore suited for seamlessly matching and integrating images from different view points and cameras (aerial and terrestrial as well as inside views) into one single reconstruction. Together with aerial images from a UAV, we are able to enrich 3D models by combining terrestrial images as well inside views of an object by joint image processing to

  20. ALE3D Simulations of Gap Closure and Surface Ignition for Cookoff Modeling

    SciTech Connect

    Howard, W M; McClelland, M A; Nichols, A L

    2006-06-22

    We are developing ALE3D models to describe the thermal, chemical and mechanical behavior during the heating, ignition and explosive phases of various cookoff phenomena. The candidate models and numerical strategies are being evaluated using benchmark cookoff experiments. ALE3D is a three-dimensional computer code capable of solving the model equations in a coupled fashion through all the phases of the cookoff in a single calculation. For the cookoff experiments, we are interested in representing behavior on widely varying timescales. We have used an implicit hydrodynamics option during the heating phase and an explicit solution method during the explosive phase. To complicate the modeling problem, high heat fluxes cause rapid temperature increases in boundary layers and lead to the formation of gaps between energetic and structural materials and ignition on surfaces. The initially solid energetic and structural materials react to produce gases, which fill the gaps. These materials can also melt and flow. Since an implicit solution method is used, simple no-strength materials models can no longer be used for liquids and gases. In this paper, we discuss and demonstrate choices of materials models for solid/liquid/gas mixtures to be used in conjunction with the implicit solution method. In addition, results are given for mesh movement strategies applied to the opening, closing, and surface ignition within gaps.

  1. Efficient 3D geometric and Zernike moments computation from unstructured surface meshes.

    PubMed

    Pozo, José María; Villa-Uriol, Maria-Cruz; Frangi, Alejandro F

    2011-03-01

    This paper introduces and evaluates a fast exact algorithm and a series of faster approximate algorithms for the computation of 3D geometric moments from an unstructured surface mesh of triangles. Being based on the object surface reduces the computational complexity of these algorithms with respect to volumetric grid-based algorithms. In contrast, it can only be applied for the computation of geometric moments of homogeneous objects. This advantage and restriction is shared with other proposed algorithms based on the object boundary. The proposed exact algorithm reduces the computational complexity for computing geometric moments up to order N with respect to previously proposed exact algorithms, from N(9) to N(6). The approximate series algorithm appears as a power series on the rate between triangle size and object size, which can be truncated at any desired degree. The higher the number and quality of the triangles, the better the approximation. This approximate algorithm reduces the computational complexity to N(3). In addition, the paper introduces a fast algorithm for the computation of 3D Zernike moments from the computed geometric moments, with a computational complexity N(4), while the previously proposed algorithm is of order N(6). The error introduced by the proposed approximate algorithms is evaluated in different shapes and the cost-benefit ratio in terms of error, and computational time is analyzed for different moment orders. PMID:20714011

  2. Effects of scanning orientation on outlier formation in 3D laser scanning of reflective surfaces

    NASA Astrophysics Data System (ADS)

    Wang, Yutao; Feng, Hsi-Yung

    2016-06-01

    Inspecting objects with reflective surfaces using 3D laser scanning is a demanded but challenging part inspection task due to undesirable specular reflections, which produce extensive outliers in the scanned point cloud. These outliers need to be removed in order to alleviate subsequent data processing issues. Many existing automatic outlier removal methods do not detect outliers according to the outlier formation properties. As a result, these methods only offer limited capabilities in removing extensive and complex outliers from scanning objects with reflective surfaces. This paper reports an empirical study which experimentally investigates the outlier formation characteristics in relation to the scanning orientation of the laser probe. The objective is to characterize the scanning orientation effects on outlier formation in order to facilitate the development of an effective outlier detection and removal method. Such an experimental investigation was hardly done before. It has been found in this work that scanning orientation can directly affect outlier extensity and occurrence in 3D laser scanning. A general guidance on proper scan path planning can then be provided with an aim to reduce the occurrence of outliers. Further, the observed dependency of outlier formation on scanning orientation can be exploited to facilitate effective and automatic outlier detection and removal.

  3. Contact Interface Verification for DYNA3D Scenario 2: Multi-Surface Contact

    SciTech Connect

    McMichael, L D

    2006-05-10

    A suite of test problems has been developed to examine contact behavior within the nonlinear, three-dimensional, explicit finite element analysis (FEA) code DYNA3D (Lin, 2005). The test problems use multiple interfaces and a combination of enforcement methods to assess the basic functionality of the contact algorithms. The results from the DYNA3D analyses are compared to closed form solutions to verify the contact behavior. This work was performed as part of the Verification and Validation efforts of LLNL W Program within the NNSA's Advanced Simulation and Computing (ASC) Program. DYNA3D models the transient dynamic response of solids and structures including the interactions between disjoint bodies (parts). A wide variety of contact surfaces are available to represent the diverse interactions possible during an analysis, including relative motion (sliding), separation and gap closure (voids), and fixed relative position (tied). The problem geometry may be defined using a combination of element formulations, including one-dimensional beam and truss elements, two-dimensional shell elements, and three-dimensional solid elements. Consequently, it is necessary to consider various element interactions during contact. This report and associated test problems examine the scenario where multiple bodies interact with each other via multiple interfaces. The test problems focus on whether any ordering issues exist in the contact logic by using a combination of interface types, contact enforcement options (i.e., penalty, Lagrange, and kinematic), and element interactions within each problem. The influence of rigid materials on interface behavior is also examined. The companion report (McMichael, 2006) and associated test problems address the basic contact scenario where one contact surface exists between two disjoint bodies. The test problems are analyzed using version 5.2 (compiled on 12/22/2005) of DYNA3D. The analytical results are used to form baseline solutions for

  4. Uncertainty studies of topographical measurements on steel surface corrosion by 3D scanning electron microscopy.

    PubMed

    Kang, K W; Pereda, M D; Canafoglia, M E; Bilmes, P; Llorente, C; Bonetto, R

    2012-02-01

    Pitting corrosion is a damage mechanism quite serious and dangerous in both carbon steel boiler tubes for power plants which are vital to most industries and stainless steels for orthopedic human implants whose demand, due to the increase of life expectation and rate of traffic accidents, has sharply increased. Reliable methods to characterize this kind of damage are becoming increasingly necessary, when trying to evaluate the advance of damage and to establish the best procedures for component inspection in order to determine remaining lives and failure mitigation. A study about the uncertainties on the topographies of corrosion pits from 3D SEM images, obtained at low magnifications (where errors are greater) and different stage tilt angles were carried out using an in-house software previously developed. Additionally, measurements of pit depths on biomaterial surfaces, subjected to two different surface treatments on stainless steels, were carried out. The different depth distributions observed were in agreement with electrochemical measurements. PMID:22051087

  5. GlaRe, a GIS tool to reconstruct the 3D surface of palaeoglaciers

    NASA Astrophysics Data System (ADS)

    Pellitero, Ramón; Rea, Brice R.; Spagnolo, Matteo; Bakke, Jostein; Ivy-Ochs, Susan; Frew, Craig R.; Hughes, Philip; Ribolini, Adriano; Lukas, Sven; Renssen, Hans

    2016-09-01

    Glacier reconstructions are widely used in palaeoclimatic studies and this paper presents a new semi-automated method for generating glacier reconstructions: GlaRe, is a toolbox coded in Python and operating in ArcGIS. This toolbox provides tools to generate the ice thickness from the bed topography along a palaeoglacier flowline applying the standard flow law for ice, and generates the 3D surface of the palaeoglacier using multiple interpolation methods. The toolbox performance has been evaluated using two extant glaciers, an icefield and a cirque/valley glacier from which the subglacial topography is known, using the basic reconstruction routine in GlaRe. Results in terms of ice surface, ice extent and equilibrium line altitude show excellent agreement that confirms the robustness of this procedure in the reconstruction of palaeoglaciers from glacial landforms such as frontal moraines.

  6. Molecular surface point environments for virtual screening and the elucidation of binding patterns (MOLPRINT 3D).

    PubMed

    Bender, Andreas; Mussa, Hamse Y; Gill, Gurprem S; Glen, Robert C

    2004-12-16

    A novel method (MOLPRINT 3D) for virtual screening and the elucidation of ligand-receptor binding patterns is introduced that is based on environments of molecular surface points. The descriptor uses points relative to the molecular coordinates, thus it is translationally and rotationally invariant. Due to its local nature, conformational variations cause only minor changes in the descriptor. If surface point environments are combined with the Tanimoto coefficient and applied to virtual screening, they achieve retrieval rates comparable to that of two-dimensional (2D) fingerprints. The identification of active structures with minimal 2D similarity ("scaffold hopping") is facilitated. In combination with information-gain-based feature selection and a naive Bayesian classifier, information from multiple molecules can be combined and classification performance can be improved. Selected features are consistent with experimentally determined binding patterns. Examples are given for angiotensin-converting enzyme inhibitors, 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitors, and thromboxane A2 antagonists. PMID:15588092

  7. 3D Ag/ZnO hybrids for sensitive surface-enhanced Raman scattering detection

    NASA Astrophysics Data System (ADS)

    Huang, Chenyue; Xu, Chunxiang; Lu, Junfeng; Li, Zhaohui; Tian, Zhengshan

    2016-03-01

    To combine the surface plasma resonance of metal and local field enhancement in metal/semiconductor interface, Ag nanoparticles (NPs) were assembled on a ZnO nanorod array which was grown by hydrothermally on carbon fibers. The construction of dimensional (3D) Surface-Enhanced Raman Scattering (SERS) substrate is used for the sensitive detection of organic pollutants with the advantages such as facile synthesis, short detection time and low cost. The hybrid substrate was manifested a high sensitivity to phenol red at a lower concentration of 1 × 10-9 M and a higher enhancement factor of 3.18 × 109. Moreover, the ZnO nanostructures decorated with Ag NPs were demonstrated self-cleaning function under UV irradiation via photocatalytic degradation of the analytic molecules. The fabrication process of the materials and sensors, optimization of the SERS behaviors for different sized Ag NPs, the mechanism of SERS and recovery were presented with a detailed discussion.

  8. Non-Newtonian Fluids Spreading with Surface Tension Effect: 3D Numerical Analysis Using FEM and Experimental Study

    NASA Astrophysics Data System (ADS)

    Hu, Bin; Kieweg, Sarah

    2010-11-01

    Gravity-driven thin film flow down an incline is studied for optimal design of polymeric drug delivery vehicles, such as anti-HIV topical microbicides. We develop a 3D FEM model using non-Newtonian mechanics to model the flow of gels in response to gravity, surface tension and shear-thinning. Constant volume setup is applied within the lubrication approximation scope. The lengthwise profiles of the 3D model agree with our previous 2D finite difference model, while the transverse contact line patterns of the 3D model are compared to the experiments. With incorporation of surface tension, capillary ridges are observed at the leading front in both 2D and 3D models. Previously published studies show that capillary ridge can amplify the fingering instabilities in transverse direction. Sensitivity studies (2D & 3D) and experiments are carried out to describe the influence of surface tension and shear-thinning on capillary ridge and fingering instabilities.

  9. Construction of Extended 3D Field of Views of the Internal Bladder Wall Surface: A Proof of Concept

    NASA Astrophysics Data System (ADS)

    Ben-Hamadou, Achraf; Daul, Christian; Soussen, Charles

    2016-09-01

    3D extended field of views (FOVs) of the internal bladder wall facilitate lesion diagnosis, patient follow-up and treatment traceability. In this paper, we propose a 3D image mosaicing algorithm guided by 2D cystoscopic video-image registration for obtaining textured FOV mosaics. In this feasibility study, the registration makes use of data from a 3D cystoscope prototype providing, in addition to each small FOV image, some 3D points located on the surface. This proof of concept shows that textured surfaces can be constructed with minimally modified cystoscopes. The potential of the method is demonstrated on numerical and real phantoms reproducing various surface shapes. Pig and human bladder textures are superimposed on phantoms with known shape and dimensions. These data allow for quantitative assessment of the 3D mosaicing algorithm based on the registration of images simulating bladder textures.

  10. A web-based platform for simulating seismic wave propagation in 3D shallow Earth models with DEM surface topography

    NASA Astrophysics Data System (ADS)

    Luo, Cong; Friederich, Wolfgang

    2016-04-01

    Realistic shallow seismic wave propagation simulation is an important tool for studying induced seismicity (e.g., during geothermal energy development). However over a long time, there is a significant problem which constrains computational seismologists from performing a successful simulation conveniently: pre-processing. Conventional pre-processing has often turned out to be inefficient and unrobust because of the miscellaneous operations, considerable complexity and insufficiency of available tools. An integrated web-based platform for shallow seismic wave propagation simulation has been built. It is aiming at providing a user-friendly pre-processing solution, and cloud-based simulation abilities. The main features of the platform for the user include: revised digital elevation model (DEM) retrieving and processing mechanism; generation of multi-layered 3D shallow Earth model geometry (the computational domain) with user specified surface topography based on the DEM; visualization of the geometry before the simulation; a pipeline from geometry to fully customizable hexahedral element mesh generation; customization and running the simulation on our HPC; post-processing and retrieval of the results over cloud. Regarding the computational aspect, currently the widely accepted specfem3D is chosen as the computational package; packages using different types of elements can be integrated as well in the future. According to our trial simulation experiments, this web-based platform has produced accurate waveforms while significantly simplifying and enhancing the pre-processing and improving the simulation success rate.

  11. Real-time 3D visualization of the thoraco-abdominal surface during breathing with body movement and deformation extraction.

    PubMed

    Povšič, K; Jezeršek, M; Možina, J

    2015-07-01

    Real-time 3D visualization of the breathing displacements can be a useful diagnostic tool in order to immediately observe the most active regions on the thoraco-abdominal surface. The developed method is capable of separating non-relevant torso movement and deformations from the deformations that are solely related to breathing. This makes it possible to visualize only the breathing displacements. The system is based on the structured laser triangulation principle, with simultaneous spatial and color data acquisition of the thoraco-abdominal region. Based on the tracking of the attached passive markers, the torso movement and deformation is compensated using rigid and non-rigid transformation models on the three-dimensional (3D) data. The total time of 3D data processing together with visualization equals 20 ms per cycle.In vitro verification of the rigid movement extraction was performed using the iterative closest point algorithm as a reference. Furthermore, a volumetric evaluation on a live subject was performed to establish the accuracy of the rigid and non-rigid model. The root mean square deviation between the measured and the reference volumes shows an error of  ±0.08 dm(3) for rigid movement extraction. Similarly, the error was calculated to be  ±0.02 dm(3) for torsional deformation extraction and  ±0.11 dm(3) for lateral bending deformation extraction. The results confirm that during the torso movement and deformation, the proposed method is sufficiently accurate to visualize only the displacements related to breathing. The method can be used, for example, during the breathing exercise on an indoor bicycle or a treadmill. PMID:26020444

  12. Surface 3D nanostructuring by tightly focused laser pulse: simulations by Lagrangian code and molecular dynamics

    NASA Astrophysics Data System (ADS)

    Inogamov, Nail A.; Zhakhovsky, Vasily V.

    2016-02-01

    There are many important applications in which the ultrashort diffraction-limited and therefore tightly focused laser pulses irradiates metal films mounted on dielectric substrate. Here we present the detailed picture of laser peeling and 3D structure formation of the thin (relative to a depth of a heat affected zone in the bulk targets) gold films on glass substrate. The underlying physics of such diffraction-limited laser peeling was not well understood previously. Our approach is based on a physical model which takes into consideration the new calculations of the two-temperature (2T) equation of state (2T EoS) and the two-temperature transport coefficients together with the coupling parameter between electron and ion subsystems. The usage of the 2T EoS and the kinetic coefficients is required because absorption of an ultrashort pulse with duration of 10-1000 fs excites electron subsystem of metal and transfers substance into the 2T state with hot electrons (typical electron temperatures 1-3 eV) and much colder ions. It is shown that formation of submicrometer-sized 3D structures is a result of the electron-ion energy transfer, melting, and delamination of film from substrate under combined action of electron and ion pressures, capillary deceleration of the delaminated liquid metal or semiconductor, and ultrafast freezing of molten material. We found that the freezing is going in non-equilibrium regime with strongly overcooled liquid phase. In this case the Stefan approximation is non-applicable because the solidification front speed is limited by the diffusion rate of atoms in the molten material. To solve the problem we have developed the 2T Lagrangian code including all this reach physics in. We also used the high-performance combined Monte- Carlo and molecular dynamics code for simulation of surface 3D nanostructuring at later times after completion of electron-ion relaxation.

  13. Initial Validation and Clinical Experience with 3D Optical-Surface-Guided Whole Breast Irradiation of Breast Cancer

    PubMed Central

    Li, S.; DeWeese, T.; Movsas, B.; Frassica, Deborah; Liu, Dezhi; Kim, Jinkoo; Chen, Qing; Walker, Eleanor

    2015-01-01

    We had introduced 3D optical surface-guided radiotherapy (SGRT) of the breast cancer (BC). We then initiated the feasibility, accuracy, and precision studies of stereovision in detection of any breast displacement through the course of treatment for total thirty breasts undertaken whole breast irradiation (WBI). In the SGRT, CT-based plan data were parsed into an in-house computer program through which the reference surfaces were generated in 3D video format. When patients were positioned on treatment Tables, real-time stereovisions were rapidly acquired while the live surface tracking shown steady thorax motion. The real-time surface images were automatically aligned with the reference surface and detected shape and location changes of the breast were online corrected through the Table and beam adjustments. Accumulated dose to each patient was computed according to the frequency distribution of the measured breast locations during beam on time. Application of SGRT had diminished large skin-marking errors of >5-mm and daily breast-setup errors of >10-mm that occurred on half of cases. Accuracy (mean) and precision (two standard deviations) of the breast displacements across the tangential field edges in the (U, V) directions were improved from (−0.5 ± 8.8, 2.2 ± 10.8) mm in conventional setup to (0.4 ± 4.6, 0.7 ± 4.4) mm in the final position while intra-fractional motion contributed only (0.1 ± 2.8, 0.0 ± 2.2) mm in free breathing. Dose uniformity and coverage to targets had both been increased by up to 10% and the lung or heart intersections have been decreased by half of those volumes if they were irradiated at the initial positions. SGRT of BC appears to be feasible regardless of skin tones, as fast as a snapshot for 3D imaging, and very accurate and precise for daily setup of flexible breast targets. Importantly, the technique allows us to verify the breast shape and position during beam-on time. PMID:22181332

  14. COMPUTER SIMULATIONS OF SPRAY RETENTION BY A 3D BARLEY PLANT: EFFECT OF FORMULATION SURFACE TENSION.

    PubMed

    Massinon, M; De Cock, N; Salah, S Ouled Taleb; Lebeau, F

    2015-01-01

    A spray retention model was used in this study to explore theoretically the effect of a range of mixture surface tension on the spray retention and the variability of deposits. The spray retention model was based on an algorithm that tested whether droplets from a virtual nozzle intercepted a 3D plant model. If so, the algorithm determined the contribution of the droplet to the overall retention depending on the droplet impact behaviour on the leaf; adhesion, rebound or splashing. The impact outcome probabilities, function of droplet impact energy, were measured using high-speed imaging on an excised indoor grown barley leaf (BBCH12) both for pure water (surface tension of 0.072 N/m) and a non-ionic super spreader (static surface tension of 0.021 N/m) depending on the surface orientation. The modification of spray mixture properties in the simulations was performed by gradually changing the spray the droplet impact probabilities between pure water and a solution with non-ionic surfactant exhibiting super spreading properties. The plant architecture was measured using a structured light scanner. The final retention was expressed as the volume of liquid retained by the whole plant relative to the projected leaf surface area in the main spray direction. One hundred simulations were performed at different volumes per hectare and flat-fan nozzles for each formulation surface tension. The coefficient of variation was used as indicator of variability of deposits. The model was able to discriminate between mixture surface tension. The spray retention increased as the mixture surface tension decreased. The variability of deposits also decreased as the surface tension decreased. The proposed modelling approach provides a suited tool for sensitivity analysis: nozzle kind, pressure, volume per hectare applied, spray mixture physicochemical properties, plant species, growth stage could be screened to determine the best spraying characteristics maximizing the retention. The

  15. 3D Imaging of Water-Drop Condensation on Hydrophobic and Hydrophilic Lubricant-Impregnated Surfaces

    PubMed Central

    Kajiya, Tadashi; Schellenberger, Frank; Papadopoulos, Periklis; Vollmer, Doris; Butt, Hans-Jürgen

    2016-01-01

    Condensation of water from the atmosphere on a solid surface is an ubiquitous phenomenon in nature and has diverse technological applications, e.g. in heat and mass transfer. We investigated the condensation kinetics of water drops on a lubricant-impregnated surface, i.e., a micropillar array impregnated with a non-volatile ionic liquid. Growing and coalescing drops were imaged in 3D using a laser scanning confocal microscope equipped with a temperature and humidity control. Different stages of condensation can be discriminated. On a lubricant-impregnated hydrophobic micropillar array these are: (1) Nucleation on the lubricant surface. (2) Regular alignment of water drops between micropillars and formation of a three-phase contact line on a bottom of the substrate. (3) Deformation and bridging by coalescence which eventually leads to a detachment of the drops from the bottom substrate. The drop-substrate contact does not result in breakdown of the slippery behaviour. Contrary, on a lubricant-impregnated hydrophilic micropillar array, the condensed water drops replace the lubricant. Consequently, the surface loses its slippery property. Our results demonstrate that a Wenzel-like to Cassie transition, required to maintain the facile removal of condensed water drops, can be induced by well-chosen surface hydrophobicity. PMID:27040483

  16. 3D Imaging of Water-Drop Condensation on Hydrophobic and Hydrophilic Lubricant-Impregnated Surfaces

    NASA Astrophysics Data System (ADS)

    Kajiya, Tadashi; Schellenberger, Frank; Papadopoulos, Periklis; Vollmer, Doris; Butt, Hans-Jürgen

    2016-04-01

    Condensation of water from the atmosphere on a solid surface is an ubiquitous phenomenon in nature and has diverse technological applications, e.g. in heat and mass transfer. We investigated the condensation kinetics of water drops on a lubricant-impregnated surface, i.e., a micropillar array impregnated with a non-volatile ionic liquid. Growing and coalescing drops were imaged in 3D using a laser scanning confocal microscope equipped with a temperature and humidity control. Different stages of condensation can be discriminated. On a lubricant-impregnated hydrophobic micropillar array these are: (1) Nucleation on the lubricant surface. (2) Regular alignment of water drops between micropillars and formation of a three-phase contact line on a bottom of the substrate. (3) Deformation and bridging by coalescence which eventually leads to a detachment of the drops from the bottom substrate. The drop-substrate contact does not result in breakdown of the slippery behaviour. Contrary, on a lubricant-impregnated hydrophilic micropillar array, the condensed water drops replace the lubricant. Consequently, the surface loses its slippery property. Our results demonstrate that a Wenzel-like to Cassie transition, required to maintain the facile removal of condensed water drops, can be induced by well-chosen surface hydrophobicity.

  17. 3D Imaging of Water-Drop Condensation on Hydrophobic and Hydrophilic Lubricant-Impregnated Surfaces.

    PubMed

    Kajiya, Tadashi; Schellenberger, Frank; Papadopoulos, Periklis; Vollmer, Doris; Butt, Hans-Jürgen

    2016-01-01

    Condensation of water from the atmosphere on a solid surface is an ubiquitous phenomenon in nature and has diverse technological applications, e.g. in heat and mass transfer. We investigated the condensation kinetics of water drops on a lubricant-impregnated surface, i.e., a micropillar array impregnated with a non-volatile ionic liquid. Growing and coalescing drops were imaged in 3D using a laser scanning confocal microscope equipped with a temperature and humidity control. Different stages of condensation can be discriminated. On a lubricant-impregnated hydrophobic micropillar array these are: (1) Nucleation on the lubricant surface. (2) Regular alignment of water drops between micropillars and formation of a three-phase contact line on a bottom of the substrate. (3) Deformation and bridging by coalescence which eventually leads to a detachment of the drops from the bottom substrate. The drop-substrate contact does not result in breakdown of the slippery behaviour. Contrary, on a lubricant-impregnated hydrophilic micropillar array, the condensed water drops replace the lubricant. Consequently, the surface loses its slippery property. Our results demonstrate that a Wenzel-like to Cassie transition, required to maintain the facile removal of condensed water drops, can be induced by well-chosen surface hydrophobicity. PMID:27040483

  18. A combined 3D and hyperspectral method for surface imaging of wounds

    NASA Astrophysics Data System (ADS)

    Paluchowski, Lukasz A.; Denstedt, Martin; Røren, Thomas; Pukstad, Brita; Randeberg, Lise Lyngsnes

    2013-03-01

    Information about the size and depth of a wound and how it is developing is an important prognostic tool in wound diagnostics. In this study a two-camera vision system has been developed to collect optical properties, shape and volume of chronic skin ulcers as tool for diagnostic assistance. This system combines the functionality of 2D imaging spectroscopy and 3D stereo-photogrammetry. A high resolution hyperspectral camera and a monochromatic video frame camera were mounted on the same scanning system. Stereo images were acquired to obtain information about the wound surface geometry. A Digital Surface Model (DSM) of the wound surface was reconstructed by applying stereophotogrammetric methods. The hyperspectral image was co-registered to the monochromatic frame image and the wound border was extracted by applying spectroscopic analysis (e.g. tissue oxygenation, pigmentation, classification). The resulting DSM of the undamaged surroundings of the wound was used to reconstruct the top surface above the wound and thus the wound volume. The analyses can, if desired, be limited to a certain depth of interest like the wound bed or wound border. Simultaneous analysis of the hyperspectral data and the surface model gives a promising, new, non-invasive tool for characterization of chronic wounds. Future work will concentrate on implementation of real time analysis and improvement of the accuracy of the system.

  19. 3D Surface Reconstruction of Rills in a Spanish Olive Grove

    NASA Astrophysics Data System (ADS)

    Brings, Christine; Gronz, Oliver; Seeger, Manuel; Wirtz, Stefan; Taguas, Encarnación; Ries, Johannes B.

    2016-04-01

    The low-cost, user-friendly photogrammetric Structure from Motion (SfM) technique is used for 3D surface reconstruction and difference calculation of an 18 meter long rill in South Spain (Andalusia, Puente Genil). The images were taken with a Canon HD video camera before and after a rill experiment in an olive grove. Recording with a video camera has compared to a photo camera a huge time advantage and the method also guarantees more than adequately overlapping sharp images. For each model, approximately 20 minutes of video were taken. As SfM needs single images, the sharpest image was automatically selected from 8 frame intervals. The sharpness was estimated using a derivative-based metric. Then, VisualSfM detects feature points in each image, searches matching feature points in all image pairs and recovers the camera and feature positions. Finally, by triangulation of camera positions and feature points the software reconstructs a point cloud of the rill surface. From the point cloud, 3D surface models (meshes) are created and via difference calculations of the pre and post model a visualization of the changes (erosion and accumulation areas) and quantification of erosion volumes are possible. The calculated volumes are presented in spatial units of the models and so real values must be converted via references. The results show that rills in olive groves have a high dynamic due to the lack of vegetation cover under the trees, so that the rill can incise until the bedrock. Another reason for the high activity is the intensive employment of machinery.

  20. 3D Surface Profile and Color Stability of Tooth Colored Filling Materials after Bleaching

    PubMed Central

    Irawan, Bryant Anthony; Irawan, Stacey Natalie; Masudi, Sam'an Malik; Sukminingrum, Ninin; Alam, Mohammad Khursheed

    2015-01-01

    This study aims to evaluate the effects of vital tooth bleaching with carbamide peroxide home bleaching and in-office bleaching on the color stability and 3D surface profile of dental restorative filling materials. Thirty discs (n = 30) measure 6 mm in diameter and 2 mm thick for each of three restorative materials. These are nanofilled composite Filtek Z350 XT, the submicron composite Estelite Σ Quick, and nanofilled glass ionomer Ketac N100 nanoionomer and were fabricated in shade A2. Each group was further divided into three subgroups (n = 10): subgroup A (Opalescence PF), subgroup B (Opalescence Boost in-office bleaching), and subgroup C (distilled water) serving as control. Samples were bleached according to the manufacturer's instructions for a period of two weeks. The Commission Internationale de L'Eclairage (CIE L*, a*, b*) system was chosen for image processing, while 3D surface profile was tested with atomic force microscopy (AFM). Statistical analyses were performed with the Mann-Whitney tests and Krusal-Wallis with a P value of ≤0.05. The three restorative materials showed significant color changes (ΔE); P ≤ 0.05. In diminishing order, the mean color changes recorded were Estelite Σ (3.82 ± 1.6) > Ketac Nano (2.97 ± 1.2) > Filtek Z350 XT (2.25 ± 1.0). However, none of the tested materials showed statistically significant changes in surface roughness; P > 0.05. PMID:26558267

  1. Automated surface micro-machining mask creation from a 3D model.

    SciTech Connect

    Schiek, Richard Louis; Schmidt, Rodney Cannon

    2004-06-01

    We have developed and implemented a method, which given a three-dimensional object can infer from topology the two-dimensional masks needed to produce that object with surface micromachining. The masks produced by this design tool can be generic, process independent masks, or if given process constraints, specific for a target process. This design tool calculates the two-dimensional mask set required to produce a given three-dimensional model by investigating the vertical topology to the model. The 3D model is first separated into bodies that are non-intersecting, made from different materials or only linked through a ground plane. Next, for each body unique vertical cross sections are located and arranged into a tree based on their topological relationship. A branch-wise search of the tree uncovers locations where deposition boundaries must lie and identifies candidate masks creating a generic mask set for the 3D model. Finally, in the last step specific process requirements are considered that may constrain the generic mask set. Constraints can include the thickness or number of deposition layers, specific ordering of masks as required by a process and type of material used in a given layer. Candidate masks are reconciled with the process constraints through a constrained optimization.

  2. 3D face recognition using simulated annealing and the surface interpenetration measure.

    PubMed

    Queirolo, Chauã C; Silva, Luciano; Bellon, Olga R P; Segundo, Maurício Pamplona

    2010-02-01

    This paper presents a novel automatic framework to perform 3D face recognition. The proposed method uses a Simulated Annealing-based approach (SA) for range image registration with the Surface Interpenetration Measure (SIM), as similarity measure, in order to match two face images. The authentication score is obtained by combining the SIM values corresponding to the matching of four different face regions: circular and elliptical areas around the nose, forehead, and the entire face region. Then, a modified SA approach is proposed taking advantage of invariant face regions to better handle facial expressions. Comprehensive experiments were performed on the FRGC v2 database, the largest available database of 3D face images composed of 4,007 images with different facial expressions. The experiments simulated both verification and identification systems and the results compared to those reported by state-of-the-art works. By using all of the images in the database, a verification rate of 96.5 percent was achieved at a False Acceptance Rate (FAR) of 0.1 percent. In the identification scenario, a rank-one accuracy of 98.4 percent was achieved. To the best of our knowledge, this is the highest rank-one score ever achieved for the FRGC v2 database when compared to results published in the literature. PMID:20075453

  3. Combining Public Domain and Professional Panoramic Imagery for the Accurate and Dense 3d Reconstruction of the Destroyed Bel Temple in Palmyra

    NASA Astrophysics Data System (ADS)

    Wahbeh, W.; Nebiker, S.; Fangi, G.

    2016-06-01

    This paper exploits the potential of dense multi-image 3d reconstruction of destroyed cultural heritage monuments by either using public domain touristic imagery only or by combining the public domain imagery with professional panoramic imagery. The focus of our work is placed on the reconstruction of the temple of Bel, one of the Syrian heritage monuments, which was destroyed in September 2015 by the so called "Islamic State". The great temple of Bel is considered as one of the most important religious buildings of the 1st century AD in the East with a unique design. The investigations and the reconstruction were carried out using two types of imagery. The first are freely available generic touristic photos collected from the web. The second are panoramic images captured in 2010 for documenting those monuments. In the paper we present a 3d reconstruction workflow for both types of imagery using state-of-the art dense image matching software, addressing the non-trivial challenges of combining uncalibrated public domain imagery with panoramic images with very wide base-lines. We subsequently investigate the aspects of accuracy and completeness obtainable from the public domain touristic images alone and from the combination with spherical panoramas. We furthermore discuss the challenges of co-registering the weakly connected 3d point cloud fragments resulting from the limited coverage of the touristic photos. We then describe an approach using spherical photogrammetry as a virtual topographic survey allowing the co-registration of a detailed and accurate single 3d model of the temple interior and exterior.

  4. Compressed-sensing (CS)-based digital breast tomosynthesis (DBT) reconstruction for low-dose, accurate 3D breast X-ray imaging

    NASA Astrophysics Data System (ADS)

    Park, Yeonok; Cho, Hyosung; Je, Uikyu; Hong, Daeki; Lee, Minsik; Park, Chulkyu; Cho, Heemoon; Choi, Sungil; Koo, Yangseo

    2014-08-01

    In practical applications of three-dimensional (3D) tomographic techniques, such as digital breast tomosynthesis (DBT), computed tomography (CT), etc., there are often challenges for accurate image reconstruction from incomplete data. In DBT, in particular, the limited-angle and few-view projection data are theoretically insufficient for exact reconstruction; thus, the use of common filtered-backprojection (FBP) algorithms leads to severe image artifacts, such as the loss of the average image value and edge sharpening. One possible approach to alleviate these artifacts may employ iterative statistical methods because they potentially yield reconstructed images that are in better accordance with the measured projection data. In this work, as another promising approach, we investigated potential applications to low-dose, accurate DBT imaging with a state-of-the-art reconstruction scheme based on compressed-sensing (CS) theory. We implemented an efficient CS-based DBT algorithm and performed systematic simulation works to investigate the imaging characteristics. We successfully obtained DBT images of substantially very high accuracy by using the algorithm and expect it to be applicable to developing the next-generation 3D breast X-ray imaging system.

  5. Statistically deformable 2D/3D registration for accurate determination of post-operative cup orientation from single standard X-ray radiograph.

    PubMed

    Zheng, Guoyan

    2009-01-01

    The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior (AP) radiograph is known inaccurate, largely due to the wide variability in individual pelvic orientation relative to X-ray plate. 2D/3D rigid image registration methods have been introduced for an accurate determination of the post-operative cup alignment with respect to an anatomical reference extracted from the CT data. Although encouraging results have been reported, their extensive usage in clinical routine is still limited. This may be explained by their requirement of a CAD model of the prosthesis, which is often difficult to be organized from the manufacturer due to the proprietary issue, and by their requirement of a pre-operative CT scan, which is not available for most retrospective studies. To address these issues, we developed and validated a statistically deformable 2D/3D registration approach for accurate determination of post-operative cup orientation. No CAD model and pre-operative CT data is required any more. Quantitative and qualitative results evaluated on cadaveric and clinical datasets are given, which indicate the validity of the approach. PMID:20426064

  6. The double-helix point spread function enables precise and accurate measurement of 3D single-molecule localization and orientation

    PubMed Central

    Backlund, Mikael P.; Lew, Matthew D.; Backer, Adam S.; Sahl, Steffen J.; Grover, Ginni; Agrawal, Anurag; Piestun, Rafael; Moerner, W. E.

    2014-01-01

    Single-molecule-based super-resolution fluorescence microscopy has recently been developed to surpass the diffraction limit by roughly an order of magnitude. These methods depend on the ability to precisely and accurately measure the position of a single-molecule emitter, typically by fitting its emission pattern to a symmetric estimator (e.g. centroid or 2D Gaussian). However, single-molecule emission patterns are not isotropic, and depend highly on the orientation of the molecule’s transition dipole moment, as well as its z-position. Failure to account for this fact can result in localization errors on the order of tens of nm for in-focus images, and ~50–200 nm for molecules at modest defocus. The latter range becomes especially important for three-dimensional (3D) single-molecule super-resolution techniques, which typically employ depths-of-field of up to ~2 μm. To address this issue we report the simultaneous measurement of precise and accurate 3D single-molecule position and 3D dipole orientation using the Double-Helix Point Spread Function (DH-PSF) microscope. We are thus able to significantly improve dipole-induced position errors, reducing standard deviations in lateral localization from ~2x worse than photon-limited precision (48 nm vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation we are able to improve from a lateral standard deviation of 116 nm (~4x worse than the precision, 28 nm) to 34 nm (within 6 nm). PMID:24817798

  7. Dynamic 3D shape of the plantar surface of the foot using coded structured light: a technical report

    PubMed Central

    2014-01-01

    Background The foot provides a crucial contribution to the balance and stability of the musculoskeletal system, and accurate foot measurements are important in applications such as designing custom insoles/footwear. With better understanding of the dynamic behavior of the foot, dynamic foot reconstruction techniques are surfacing as useful ways to properly measure the shape of the foot. This paper presents a novel design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Methods Engineering and clinical tests were carried out to test the accuracy and repeatability of the system. Accuracy experiments involved imaging a planar surface from different orientations and elevations and measuring the fitting errors of the data to a plane. Repeatability experiments were done using reconstructions from 27 different subjects, where for each one both right and left feet were reconstructed in static and dynamic conditions over two different days. Results The static accuracy of the system was found to be 0.3 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.4 mm (static case) and 2.8 mm (dynamic case). Conclusion The results obtained in the experiments show positive accuracy and repeatability results when compared to current literature. The design also shows to be superior to the systems available in the literature in several factors. Further studies need to be done to quantify the reliability of the system in clinical environments. PMID:24456711

  8. Moiré deflectometry under incoherent illumination: 3D profiler for specular surfaces

    NASA Astrophysics Data System (ADS)

    Hirose, Tomohiro; Kitayama, Tsunaji

    2013-04-01

    We present a novel method for measuring a curved specular surface profile, which is the moiré deflectometry under incoherent (white light) illumination. In our proposed system, moiré is produced by a superposition of two pairs of Ronchi gratings to obtain orthogonal components of a normal vector on a surface under test. The grating pair was moved along an axis perpendicular to the grating plane to modulate a spatial frequency of the moiré. The moiré is reflected by a specular object, then observed with a calibrated stereo camera. Normal vector distribution of the tested surface was measured by analysis of intensity oscillations captured by the stereo camera as a function of the position of the moved grating. A surface profile was reconstructed by an integration calculation. We successfully measured surface profiles of deeply curved mirrors with the curvature from -20 to 20 m-1 by our system. Moreover, part of a miniature vehicle body, which has a complex curved specular surface, was also measured. Additionally, we theoretically and experimentally studied a measurable angle variation of the normal vector on the tested surface by our measurement system. We found that our system can allow to measure the angle deviation of 0.05 deg of the normal vector. This method has no ambiguity of slope and height measurements which is appeared in conventional deflectmetric metrologies. Furthermore, our proposed system only needs a single step calibration. Hence, the methodology we proposed has a potential to be developed into a 3D profiler for complex specular surfaces.

  9. Carbon deposition from aromatic solvents onto active intact 3d metal surface at ambient conditions.

    PubMed

    Safronov, A P; Kurlyandskaya, G V; Chlenova, A A; Kuznetsov, M V; Bazhin, D N; Beketov, I V; Sanchez-Ilarduya, M B; Martinez-Amesti, A

    2014-03-25

    The process of carbon deposition onto 3d metal surface immersed in aromatic solvents (benzene, toluene, xylene) at ambient conditions was studied for as-prepared magnetic nanoparticles (MNPs) and Fe-based films by thermal analysis, mass spectrometry, X-ray diffraction, X-ray photoelectron spectroscopy, Raman spectroscopy, electron microscopy, and energy-dispersive X-ray spectroscopy. The mechanism of the deposition at the interface is likely the heterogeneous Scholl oxidation of the aromatic hydrocarbons, which is the cationic polymerization of the aryl rings. It results in the formation of polycyclic aromatic hydrocarbons (PAH) chemically bonded to the surface of a MNP or thin metallic film. The benzene rings in the polycyclic deposit do not maintain planar aligned structures and do not provide delocalization of the π-electrons in the zone structure. Contrary to the dense graphite layers, the polycyclic layers, although chemically bonded, are not attached tightly to the surface. Such "hairlike" structure of the carboneous deposit might be especially favorable for the applications that imply the enhanced interaction at the surfaces incorporated in the functional matrices (polymeric composites or biosensors). The aromatic chemical nature of the deposit provides strong interaction with most polymers, while its loose structure favors conformational mobility of macromolecular chains at the interface. PMID:24593324

  10. Comparison of two different surfaces for 3d model abstraction in support of remote sensing simulations

    SciTech Connect

    Pope, Paul A; Ranken, Doug M

    2010-01-01

    A method for abstracting a 3D model by shrinking a triangular mesh, defined upon a best fitting ellipsoid surrounding the model, onto the model's surface has been previously described. This ''shrinkwrap'' process enables a semi-regular mesh to be defined upon an object's surface. This creates a useful data structure for conducting remote sensing simulations and image processing. However, using a best fitting ellipsoid having a graticule-based tessellation to seed the shrinkwrap process suffers from a mesh which is too dense at the poles. To achieve a more regular mesh, the use of a best fitting, subdivided icosahedron was tested. By subdividing each of the twenty facets of the icosahedron into regular triangles of a predetermined size, arbitrarily dense, highly-regular starting meshes can be created. Comparisons of the meshes resulting from these two seed surfaces are described. Use of a best fitting icosahedron-based mesh as the seed surface in the shrinkwrap process is preferable to using a best fitting ellipsoid. The impacts to remote sensing simulations, specifically generation of synthetic imagery, is illustrated.

  11. The Devil is in the Details: Using X-Ray Computed Tomography to Develop Accurate 3D Grain Characteristics and Bed Structure Metrics for Gravel Bed Rivers

    NASA Astrophysics Data System (ADS)

    Voepel, H.; Hodge, R. A.; Leyland, J.; Sear, D. A.; Ahmed, S. I.

    2014-12-01

    Uncertainty for bedload estimates in gravel bed rivers is largely driven by our inability to characterize the arrangement and orientation of the sediment grains within the bed. The characteristics of the surface structure are produced by the water working of grains, which leads to structural differences in bedforms through differential patterns of grain sorting, packing, imbrication, mortaring and degree of bed armoring. Until recently the technical and logistical difficulties of characterizing the arrangement of sediment in 3D have prohibited a full understanding of how grains interact with stream flow and the feedback mechanisms that exist. Micro-focus X-ray CT has been used for non-destructive 3D imaging of grains within a series of intact sections of river bed taken from key morphological units (see Figure 1). Volume, center of mass, points of contact, protrusion and spatial orientation of individual surface grains are derived from these 3D images, which in turn, facilitates estimates of 3D static force properties at the grain-scale such as pivoting angles, buoyancy and gravity forces, and grain exposure. By aggregating representative samples of grain-scale properties of localized interacting sediment into overall metrics, we can compare and contrast bed stability at a macro-scale with respect to stream bed morphology. Understanding differences in bed stability through representative metrics derived at the grain-scale will ultimately lead to improved bedload estimates with reduced uncertainty and increased understanding of interactions between grain-scale properties on channel morphology. Figure 1. CT-Scans of a water worked gravel-filled pot. a. 3D rendered scan showing the outer mesh, and b. the same pot with the mesh removed. c. vertical change in porosity of the gravels sampled in 5mm volumes. Values are typical of those measured in the field and lab. d. 2-D slices through the gravels at 20% depth from surface (porosity = 0.35), and e. 75% depth from

  12. Metal-mesh based transparent electrode on a 3-D curved surface by electrohydrodynamic jet printing

    NASA Astrophysics Data System (ADS)

    Seong, Baekhoon; Yoo, Hyunwoong; Dat Nguyen, Vu; Jang, Yonghee; Ryu, Changkook; Byun, Doyoung

    2014-09-01

    Invisible Ag mesh transparent electrodes (TEs), with a width of 7 μm, were prepared on a curved glass surface by electrohydrodynamic (EHD) jet printing. With a 100 μm pitch, the EHD jet printed the Ag mesh on the convex glass which had a sheet resistance of 1.49 Ω/□. The printing speed was 30 cm s-1 using Ag ink, which had a 10 000 cPs viscosity and a 70 wt% Ag nanoparticle concentration. We further showed the performance of a 3-D transparent heater using the Ag mesh transparent electrode. The EHD jet printed an invisible Ag grid transparent electrode with good electrical and optical properties with promising applications on printed optoelectronic devices.

  13. Gray coded trapezoidal fringes for 3-D surface-shape measurement

    NASA Astrophysics Data System (ADS)

    Pérez, Oscar G.; Flores, Jorge L.; García-Torales, G.; Muñoz-G, J. A.; Soto, Horacio; Balderas, Sandra E.

    2014-09-01

    We propose a two-step trapezoidal-pattern phase-shifting method for 3-D surface-shape measurements. Shape measurements by trapezoidal phase-shifting methods require high-quality trapezoidal patterns. Furthermore, most of the video projectors are nonlinear, making it difficult to generate high quality phase without nonlinearity calibration and correction. To overcome the limitations, we propose a method for synthesizing trapezoidal intensity fringes as a way to solve the problems caused by projector/camera gamma nonlinearity. The fringe generation technique consists of projecting and acquiring a temporal sequence of strictly binary color patterns (Gray code), whose (adequately weighted) average leads to trapezoidal fringe patterns with the required number of bits, which allows a reliable three-dimensional profile reconstruction using phase-shifting methods. Validation experiments are presented.

  14. Understanding surface processes 3D imaging from micro-scale to regional scale

    NASA Astrophysics Data System (ADS)

    Jaboyedoff, Michel; Abellan, Antonio; Carrea, Dario; Derron, Marc-Henri; Franz, Martin; Guerin, Antoine; Humair, Florian; Matasci, Battista; Michoud, Clément; Nicolet, Pierrick; Penna, Ivanna; Rudaz, Benjamin; Voumard, Jeremie; Wyser, Emmanuel

    2015-04-01

    The production of topography using remote sensing techniques has considerably been improved during the last fifteen years due to the advances in electronics and to the increase of computing power. The earth surface is monitored at all the scales using Space Shuttle Missions (SRTM) digital elevation model (DEM), or using laser scanner (LS), both terrestrial (TLS) and airborne (ALS), with accuracies that can reach up to less than 50 microns for observations of objects at meter scale. Recently, photogrammetry has been pushed by the progress of LiDAR and thanks to the advance in image recognition. It led to the development of new techniques such as structure-from-motion (SFM), which allows obtaining 3D point cloud based on several pictures of the same object taken from several point of views. Both LiDAR and Photogrammetry produce 3D point clouds. One of the current 3D applications is the surface changes, which is often based simply on the subtraction of DEM at different time intervals, leading to a simple superficial description of the natural processes without information on the mass transport. However, a point cloud has much more information than a simple surface. For instance, shape recognition can be used to track objects or deformations such as a rock mass toppling, either using the shape of the point cloud or a specific moving element. Such method permits, for instance, to study in detail pre-failure accelerations, and are now routinely used in mining industry. Other methods are coupling images and DEMs and are used, for example, to capture the surface vectors of displacements in order to deduce the surface deformations of landslides. These types of surveys have now broad applications to all kinds of erosional processes. The coastal retreat can be monitored, and it displays in some places several centimetres per year of retreat on average. The sediment transports in torrent are now better constraint showing clearly pulses. The seasonal cycles can as well be

  15. Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surfaces.

    PubMed

    Dastane, A; Vaidyanathan, T K; Vaidyanathan, J; Mehra, R; Hesby, R

    1996-01-01

    It is necessary to visualize and reconstruct tissue anatomic surfaces accurately for a variety of oral rehabilitation applications such as surface wear characterization and automated fabrication of dental restorations, accuracy of reproduction of impression and die materials, etc. In this investigation, a 3-D digitization and computer-graphic system was developed for surface characterization. The hardware consists of a profiler assembly for digitization in an MTS biomechanical test system with an artificial mouth, an IBM PS/2 computer model 70 for data processing and a Hewlett-Packard laser printer for hardcopy outputs. The software used includes a commercially available Surfer 3-D graphics package, a public domain data-fitting alignment software and an inhouse Pascal program for intercommunication plus some other limited tasks. Surfaces were digitized before and after rotation by angular displacement, the digital data were interpolated by Surfer to provide a data grid and the surfaces were computer graphically reconstructed: Misaligned surfaces were aligned by the data-fitting alignment software under different choices of parameters. The effect of different interpolation parameters (e.g. grid size, method of interpolation) and extent of rotation on the alignment accuracy was determined. The results indicate that improved alignment accuracy results from optimization of interpolation parameters and minimization of the initial misorientation between the digitized surfaces. The method provides important advantages for surface reconstruction and visualization, such as overlay of sequentially generated surfaces and accurate alignment of pairs of surfaces with small misalignment. PMID:8850158

  16. Study of the effects of surface cladding on 3D transmon

    NASA Astrophysics Data System (ADS)

    Yoscovits, Zachary Robert

    Quantum computing is a very interesting field, due to the ability of quantum computers to solve many problems much faster than a classical computer. Superconducting qubits are electronic circuits composed of superconducting capacitors, inductors and Josephson junctions, which can implement a physical qubit. However they need improvements in their coherence time to create a viable quantum computing. In this work I study the effect on decoherence caused by two level systems in the native oxide that forms on the surface of qubit. To this end I fabricate 3D transmon qubits using materials grown my molecular beam epitaxy, to which a variety of different surface treatments had been applied. I began by fabricating qubits from niobium/aluminum oxide/niobium trilayers. To this end I developed a self-aligned process for fabricating sub-micron Josephson junctions. This process presented many challenges. During the development of this process, it became clear that niobium was an inferior material for fabricating qubits compared to aluminum. I then switched to making qubits from Aluminum. I began by studying the growth of aluminum on sapphire, and was able to achieve aluminum films with an RMS roughness of 0.2 nm by growing on c-plane sapphire that had been annealed in oxygen at 1100 °C and dipped in BOE. Next I fabricated 3D transmon qubits by adapting the standard shadowmask process for use with MBE. I fabricated qubits with a long in situ oxidation to fully passivate the surface before exposure to air. I also passivated the surface by means of growing co deposited aluminum oxide, and by grown aluminum nitride using a nitrogen plasma source. The coherence times of these qubits were compared to those a control sample that had been exposed to air immediately after growth. Overall it doesn't appear that cladding the surface changes the coherence time much, however it is difficult to form conclusions with this small sample size. The coated samples appeared to have slightly

  17. Developed Design for Humeral Head Replacement Using 3D Surface Mapping

    NASA Astrophysics Data System (ADS)

    Salah, H. R.

    2014-12-01

    Assessment of dimensional and geometrical data on the humeral head replacement (HHR) objects is essential for solving the relevant designing problems in the physics of reverse engineering (RE). In this work, 2D-assessment for human humerus was performed using the computed tomography (CT) technique within the RE plan, after which the 2D images of humeral objects were converted into 3D images. The conversion was successful and indicated a clear difference in the 2D and 3D estimates of sizes and geometry of the humerus. The authors have analyzed and confirmed experimentally the statistical information on the relevant anatomical objects. The results of finite-element simulation of the compressive stresses affecting the geometry of 3D surface mapping were analyzed using SolidWorks software. For developing the biomechanical design of an HHR object suitable biomaterials were selected, and different metal-based biomaterials are discussed as applied at various loads. New methodology is presented for the size estimation of humeral head - both anatomical and artificial - in 3D-shape. A detailed interpretation is given for the results of CT D-measurements. Izmēru un ģeometrisko datu novērtējums, kas attiecas uz pleca kaula galviņas nomaiņas (PKGN) objektiem, nepieciešams, lai risinātu virkni reversīvās inženierijas (RI) problēmu. Šajā darbā cilvēka pleca kaula galviņas divdimensiju novērtējums tika veikts ar datortomogrāfijas palīdzību (RI) ietvaros, un pēc tam objekta divdimensiju attēlojums tika pārveidots trīsdimensiju. Pārveidojums bija sekmīgs, parādot pleca kaula galviņas izmēru un ģeometrijas atšķirības starp 2D un 3D novērtējumiem. Autori izanalizēja un eksperimentāli apstiprināja statistisko informāciju pēc dotā veida anatomiskiem objektiem. Saspiešanas sasprindzinājumi, kuri ietekmē trīsdimensiju virsmas attēlojuma ģeometriju, tika analizēti ar gala-elementu simulācijas metodi, lietojot programmu Solid

  18. Surface-based matching of 3D point clouds with variable coordinates in source and target system

    NASA Astrophysics Data System (ADS)

    Ge, Xuming; Wunderlich, Thomas

    2016-01-01

    The automatic co-registration of point clouds, representing three-dimensional (3D) surfaces, is an important technique in 3D reconstruction and is widely applied in many different disciplines. An alternative approach is proposed here that estimates the transformation parameters of one or more 3D search surfaces with respect to a 3D template surface. The approach uses the nonlinear Gauss-Helmert model, minimizing the quadratically constrained least squares problem. This approach has the ability to match arbitrarily oriented 3D surfaces captured from a number of different sensors, on different time-scales and at different resolutions. In addition to the 3D surface-matching paths, the mathematical model allows the precision of the point clouds to be assessed after adjustment. The error behavior of surfaces can also be investigated based on the proposed approach. Some practical examples are presented and the results are compared with the iterative closest point and the linear least-squares approaches to demonstrate the performance and benefits of the proposed technique.

  19. Tuning 3D topography on biomimetic surface for efficient self-cleaning and microfluidic manipulation

    NASA Astrophysics Data System (ADS)

    Guan, Wei-Sheng; Huang, Han-Xiong; Chen, An-Fu

    2015-03-01

    Currently, micro-/nanotopography on polymeric replica is generally limited to 2D when a mechanical demolding approach is applied. In this work, one-step replication of bio-inspired 3D topography is achieved using microinjection compression molding with novel dual-layer molds. Using a proposed flexible template, the replica topography and wettability are highly tunable during molding. Moreover, dual-scale topography on the mold is developed by coating the micropatterned insert with submicron silica particles. Contact angle and roll-off angle measurements indicate the lotus leaf, rose petal and rice leaf effects on biomimetic surfaces. Among the three kinds of surfaces, the petal-inspired surface possesses the superior performance in self-cleaning submicron contaminants and mechanical robustness, which is highly correlated to the low roughness-induced adhesive superhydrophobicity and the absence of fragile submicron-/nanostructure, respectively. Furthermore, a multi-layer mold structure is proposed for fabricating the open microfluidic devices. The embedment of the hydrophilic and hydrophobic silica particles in the microstructured open channel and the hydrophobic silica particles in the background area during replication renders the wettability contrast sharp, realizing the self-driven flow of microfluid confined within the open microchannel.

  20. Evaluating Dense 3d Reconstruction Software Packages for Oblique Monitoring of Crop Canopy Surface

    NASA Astrophysics Data System (ADS)

    Brocks, S.; Bareth, G.

    2016-06-01

    Crop Surface Models (CSMs) are 2.5D raster surfaces representing absolute plant canopy height. Using multiple CMSs generated from data acquired at multiple time steps, a crop surface monitoring is enabled. This makes it possible to monitor crop growth over time and can be used for monitoring in-field crop growth variability which is useful in the context of high-throughput phenotyping. This study aims to evaluate several software packages for dense 3D reconstruction from multiple overlapping RGB images on field and plot-scale. A summer barley field experiment located at the Campus Klein-Altendorf of University of Bonn was observed by acquiring stereo images from an oblique angle using consumer-grade smart cameras. Two such cameras were mounted at an elevation of 10 m and acquired images for a period of two months during the growing period of 2014. The field experiment consisted of nine barley cultivars that were cultivated in multiple repetitions and nitrogen treatments. Manual plant height measurements were carried out at four dates during the observation period. The software packages Agisoft PhotoScan, VisualSfM with CMVS/PMVS2 and SURE are investigated. The point clouds are georeferenced through a set of ground control points. Where adequate results are reached, a statistical analysis is performed.

  1. 3-D Surface Depression Profiling Using High Frequency Focused Air-Coupled Ultrasonic Pulses

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Kautz, Harold E.; Abel, Phillip B.; Whalen, Mike F.; Hendricks, J. Lynne; Bodis, James R.

    1999-01-01

    Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. This article shows quantitative surface topography profiles as obtained using only high-frequency focused air-coupled ultrasonic pulses. The profiles were obtained using a profiling system developed by NASA Glenn Research Center and Sonix, Inc (via a formal cooperative agreement). (The air transducers are available as off-the-shelf items from several companies.) The method is simple and reproducible because it relies mainly on knowledge and constancy of the sound velocity through the air. The air transducer is scanned across the surface and sends pulses to the sample surface where they are reflected back from the surface along the same path as the incident wave. Time-of-flight images of the sample surface are acquired and converted to depth/surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in air (V). The system has the ability to resolve surface depression variations as small as 25 microns, is useable over a 1.4 mm vertical depth range, and can profile large areas only limited by the scan limits of the particular ultrasonic system. (Best-case depth resolution is 0.25 microns which may be achievable with improved isolation from vibration and air currents.) The method using an optimized configuration is reasonably rapid and has all quantitative analysis facilities on-line including 2-D and 3-D visualization capability, extreme value filtering (for faulty data), and leveling capability. Air-coupled surface profilometry is applicable to plate-like and curved samples. In this article, results are shown for several proof-of-concept samples, plastic samples burned in microgravity on the STS-54 space shuttle mission, and a partially-coated cylindrical ceramic

  2. Comparative 3D quantitative analyses of trapeziometacarpal joint surface curvatures among living catarrhines and fossil hominins.

    PubMed

    Marzke, M W; Tocheri, M W; Steinberg, B; Femiani, J D; Reece, S P; Linscheid, R L; Orr, C M; Marzke, R F

    2010-01-01

    Comparisons of joint surface curvature at the base of the thumb have long been made to discern differences among living and fossil primates in functional capabilities of the hand. However, the complex shape of this joint makes it difficult to quantify differences among taxa. The purpose of this study is to determine whether significant differences in curvature exist among selected catarrhine genera and to compare these genera with hominin fossils in trapeziometacarpal curvature. Two 3D approaches are used to quantify curvatures of the trapezial and metacarpal joint surfaces: (1) stereophotogrammetry with nonuniform rational B-spline (NURBS) calculation of joint curvature to compare modern humans with captive chimpanzees and (2) laser scanning with a quadric-based calculation of curvature to compare modern humans and wild-caught Pan, Gorilla, Pongo, and Papio. Both approaches show that Homo has significantly lower curvature of the joint surfaces than does Pan. The second approach shows that Gorilla has significantly more curvature than modern humans, while Pongo overlaps with humans and African apes. The surfaces in Papio are more cylindrical and flatter than in Homo. Australopithecus afarensis resembles African apes more than modern humans in curvatures, whereas the Homo habilis trapezial metacarpal surface is flatter than in all genera except Papio. Neandertals fall at one end of the modern human range of variation, with smaller dorsovolar curvature. Modern human topography appears to be derived relative to great apes and Australopithecus and contributes to the distinctive human morphology that facilitates forceful precision and power gripping, fundamental to human manipulative activities. PMID:19544574

  3. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    PubMed

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. PMID:26617403

  4. 3-D Surface Visualization of pH Titration "Topos": Equivalence Point Cliffs, Dilution Ramps, and Buffer Plateaus

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul; MacCarthy, Patrick

    2014-01-01

    3-D topographic surfaces ("topos") can be generated to visualize how pH behaves during titration and dilution procedures. The surfaces are constructed by plotting computed pH values above a composition grid with volume of base added in one direction and overall system dilution on the other. What emerge are surface features that…

  5. Accurate and Fully Automatic Hippocampus Segmentation Using Subject-Specific 3D Optimal Local Maps Into a Hybrid Active Contour Model

    PubMed Central

    Gkontra, Polyxeni; Daras, Petros; Maglaveras, Nicos

    2014-01-01

    Assessing the structural integrity of the hippocampus (HC) is an essential step toward prevention, diagnosis, and follow-up of various brain disorders due to the implication of the structural changes of the HC in those disorders. In this respect, the development of automatic segmentation methods that can accurately, reliably, and reproducibly segment the HC has attracted considerable attention over the past decades. This paper presents an innovative 3-D fully automatic method to be used on top of the multiatlas concept for the HC segmentation. The method is based on a subject-specific set of 3-D optimal local maps (OLMs) that locally control the influence of each energy term of a hybrid active contour model (ACM). The complete set of the OLMs for a set of training images is defined simultaneously via an optimization scheme. At the same time, the optimal ACM parameters are also calculated. Therefore, heuristic parameter fine-tuning is not required. Training OLMs are subsequently combined, by applying an extended multiatlas concept, to produce the OLMs that are anatomically more suitable to the test image. The proposed algorithm was tested on three different and publicly available data sets. Its accuracy was compared with that of state-of-the-art methods demonstrating the efficacy and robustness of the proposed method. PMID:27170866

  6. Accurate and Fully Automatic Hippocampus Segmentation Using Subject-Specific 3D Optimal Local Maps Into a Hybrid Active Contour Model.

    PubMed

    Zarpalas, Dimitrios; Gkontra, Polyxeni; Daras, Petros; Maglaveras, Nicos

    2014-01-01

    Assessing the structural integrity of the hippocampus (HC) is an essential step toward prevention, diagnosis, and follow-up of various brain disorders due to the implication of the structural changes of the HC in those disorders. In this respect, the development of automatic segmentation methods that can accurately, reliably, and reproducibly segment the HC has attracted considerable attention over the past decades. This paper presents an innovative 3-D fully automatic method to be used on top of the multiatlas concept for the HC segmentation. The method is based on a subject-specific set of 3-D optimal local maps (OLMs) that locally control the influence of each energy term of a hybrid active contour model (ACM). The complete set of the OLMs for a set of training images is defined simultaneously via an optimization scheme. At the same time, the optimal ACM parameters are also calculated. Therefore, heuristic parameter fine-tuning is not required. Training OLMs are subsequently combined, by applying an extended multiatlas concept, to produce the OLMs that are anatomically more suitable to the test image. The proposed algorithm was tested on three different and publicly available data sets. Its accuracy was compared with that of state-of-the-art methods demonstrating the efficacy and robustness of the proposed method. PMID:27170866

  7. Building a 3D geological near surface model from borehole and laboratory data

    NASA Astrophysics Data System (ADS)

    Sala, P.; Tisato, N.; Pfiffner, O. A.; Frehner, M.

    2012-04-01

    The interpretation of active seismic survey data usually results in a subsurface P-wave velocity model. Such models commonly do not include the near surface, but end a few hundreds of meters beneath the Earth's surface. However, near surface effects, such as low-velocity zones or topography can influence the seismic signal significantly. Therefore, it is important to extend the P-wave velocity model all the way to the Earth's surface. As a test site of this study, we use the underground gas storage facility in Chémery (France), located at the south-western border of the Paris Basin. Velocities and lithological data of the shallow formations can be found in a public dataset, which collects data of a large number of short boreholes (BRGM online catalog: infoterre.brgm.fr/viewer). From the lithological data a structural model defined by surfaces gridded from well markers and faults derived from the analysis of these surfaces, is generated. The generation of the structural model comprised some major challenges, mainly because the borehole data represent 1D vertical pinpoints into the subsurface, rather than 2D sections as it is the case for most seismic surveys. This complicated the cross-correlation between the boreholes and the interpolation of the lithological formations in the 3D space. After the structural model has been generated, the velocity logs were upscaled to the model and interpolated to generate a near-surface P wave velocity model. To better constrain the velocity model, laboratory measurements of P-wave velocity were conducted. We collected 24 hand specimens from outcrops, from which we drilled core plugs. The sampled lithologies are 6 different sedimentary rock types, mostly calcarenites. The measurements were conducted employing the pulse transmission method for compression (Vp) and shear (Vs) waves in dry and fully water saturated conditions. Density and porosity were measured with two different methods: (1) with a helium pycnometer, and (2

  8. RKKY interaction in P-N junction based on surface states of 3D topological insulator

    NASA Astrophysics Data System (ADS)

    Zhang, Shuhui; Yang, Wen; Chang, Kai

    The RKKY interaction mediated by conduction electrons supplies a mechanism to realize the long-range coupling of localized spins which is desired for the spin devices. Here, we examine the controllability of RKKY interaction in P-N junction (PNJ) based on surface states of 3D topological insulator (3DTI). In this study, through quantum way but not usual classical analogy to light propagation, the intuitive picture for electron waves across the interface of PNJ is obtained, e.g., Klein tunneling, negative refraction and focusing. Moreover, we perform the numerical calculations for all kinds of RKKY interaction including the Heisenberg, Ising, and Dzyaloshinskii-Moriya terms. We find the focusing of surface states leads to the local augmentation of RKKY interaction. Most importantly, a dimension transition occurs, i.e., the decay rate of RKKY interaction from the deserved 1/R 2 to 1/ R . In addition, the quadratic gate-dependence of RKKY interaction is also beneficial to the application of 3DTI PNJ in the fields of spintronics and quantum computation. This work was supported by the MOST (Grant No. 2015CB921503, and No. 2014CB848700) and NSFC (Grant No. 11434010, No. 11274036, No. 11322542, and No. 11504018).

  9. Surface modeling and segmentation of the 3D airway wall in MSCT

    NASA Astrophysics Data System (ADS)

    Ortner, Margarete; Fetita, Catalin; Brillet, Pierre-Yves; Pr"teux, Françoise; Grenier, Philippe

    2011-03-01

    Airway wall remodeling in asthma and chronic obstructive pulmonary disease (COPD) is a well-known indicator of the pathology. In this context, current clinical studies aim for establishing the relationship between the airway morphological structure and its function. Multislice computed tomography (MSCT) allows morphometric assessment of airways, but requires dedicated segmentation tools for clinical exploitation. While most of the existing tools are limited to cross-section measurements, this paper develops a fully 3D approach for airway wall segmentation. Such approach relies on a deformable model which is built up as a patient-specific surface model at the level of the airway lumen and deformed to reach the outer surface of the airway wall. The deformation dynamics obey a force equilibrium in a Lagrangian framework constrained by a vector field which avoids model self-intersections. The segmentation result allows a dense quantitative investigation of the airway wall thickness with a deeper insight at bronchus subdivisions than classic cross-section methods. The developed approach has been assessed both by visual inspection of 2D cross-sections, performed by two experienced radiologists on clinical data obtained with various protocols, and by using a simulated ground truth (pulmonary CT image model). The results confirmed a robust segmentation in intra-pulmonary regions with an error in the range of the MSCT image resolution and underlined the interest of the volumetric approach versus purely 2D methods.

  10. Electronic and spectroscopic properties of early 3d metal atoms on a graphite surface

    NASA Astrophysics Data System (ADS)

    Rakotomahevitra, A.; Garreau, G.; Demangeat, C.; Parlebas, J. C.

    1995-07-01

    High-sensitivity magneto-optic Kerr effect experiments failed to detect manifestations of magnetism in epitaxial films of V on Ag(100) substrates. More recently V 3s XPS of freshly evaporated V clusters on graphite exhibited the appearance of a satellite structure which has then been interpreted by the effect of surface magnetic moments on V. It is the absence of unambiguous results on the electronic properties of early 3d supported metals that prompts us to examine the problem. Our purpose is twofold. In a first part, after a total energy calculation within a tight-binding method which yields the equilibrium position of a given adatom, we use the Hartree-Fock approximation to find out a possible magnetic solution of V (or Cr) upon graphite for a reasonable value of the exchange integral Jdd. In a second part the informations given by the density of states of the graphite surface as well as the additional states of the adsorbed atom are taken into account through a generalised impurity Anderson Hamiltonian which incorporates the various Coulomb and exchange interactions necessary to analyse the 3s XPS results.

  11. Geometric Neural Computing for 2D Contour and 3D Surface Reconstruction

    NASA Astrophysics Data System (ADS)

    Rivera-Rovelo, Jorge; Bayro-Corrochano, Eduardo; Dillmann, Ruediger

    In this work we present an algorithm to approximate the surface of 2D or 3D objects combining concepts from geometric algebra and artificial neural networks. Our approach is based on the self-organized neural network called Growing Neural Gas (GNG), incorporating versors of the geometric algebra in its neural units; such versors are the transformations that will be determined during the training stage and then applied to a point to approximate the surface of the object. We also incorporate the information given by the generalized gradient vector flow to select automatically the input patterns, and also in the learning stage in order to improve the performance of the net. Several examples using medical images are presented, as well as images of automatic visual inspection. We compared the results obtained using snakes against the GSOM incorporating the gradient information and using versors. Such results confirm that our approach is very promising. As a second application, a kind of morphing or registration procedure is shown; namely the algorithm can be used when transforming one model at time t 1 into another at time t 2. We include also examples applying the same procedure, now extended to models based on spheres.

  12. Correlations of Surface Deformation and 3D Flow Field in a Compliant Wall Turbulent Channel Flow.

    NASA Astrophysics Data System (ADS)

    Wang, Jin; Zhang, Cao; Katz, Joseph

    2015-11-01

    This study focuses on the correlations between surface deformation and flow features, including velocity, vorticity and pressure, in a turbulent channel flow over a flat, compliant Polydimethylsiloxane (PDMS) wall. The channel centerline velocity is 2.5 m/s, and the friction Reynolds number is 2.3x103. Analysis is based on simultaneous measurements of the time resolved 3D velocity and surface deformation using tomographic PIV and Mach-Zehnder Interferometry. The volumetric pressure distribution is calculated plane by plane by spatially integrating the material acceleration using virtual boundary, omni-directional method. Conditional sampling based on local high/low pressure and deformation events reveals the primary flow structures causing the deformation. High pressure peaks appear at the interface between sweep and ejection, whereas the negative deformations peaks (dent) appear upstream, under the sweeps. The persistent phase lag between flow and deformations are presumably caused by internal damping within the PDMS. Some of the low pressure peaks and strong ejections are located under the head of hairpin vortices, and accordingly, are associated with positive deformation (bump). Others bumps and dents are correlated with some spanwise offset large inclined quasi-streamwise vortices that are not necessarily associated with hairpins. Sponsored by ONR.

  13. Using the 3D-SMS for finding starting configurations in imaging systems with freeform surfaces

    NASA Astrophysics Data System (ADS)

    Satzer, Britta; Richter, Undine; Lippmann, Uwe; Metzner, Gerburg S.; Notni, Gunther; Gross, Herbert

    2015-09-01

    As the scientific field of the freeform optics is newly developing, there is only a small number of approved starting systems for the imaging lens design. We investigate the possibility to generate starting configurations of freeform lenses with the Simultaneous Multiple Surface (SMS) method. Surface fit and transfer to the ray tracing program are discussed in detail. Based on specific examples without rotational symmetry, we analyze the potential of such starting systems. The tested systems evolve from Scheimpflug configurations or have arbitrarily tilted image planes. The optimization behavior of the starting systems retrieved from the 3D-SMS is compared to classical starting configurations, like an aspheric lens. Therefore we evaluate the root mean square (RMS) spot radius before and after the optimization as well as the speed of convergence. In result the performance of the starting configurations is superior. The mean RMS spot diameter is reduced about up to 17.6 % in comparison to an aspheric starting configuration and about up to 28 % for a simple plane plate.

  14. Skyrmion-induced bound states on the surface of 3D Topological Insulators

    NASA Astrophysics Data System (ADS)

    Andrikopoulos, Dimitrios; Soree, Bart

    In this work, we study the interaction between the surface state of a 3D Topological Insulator and a skyrmion magnetic texture. The skyrmion texture couples to the spin of the surface state electron with strength ΔS. Vortex and hedgehog skyrmion and anti-skyrmion structures are considered and their interaction is compared. Due to the vortex structure, the interaction of the in-plane components can be neglected and a step function is used to describe the skyrmion magnetization profile. In the hedgehog case, it is shown that the in-plane components cannot be disregarded and thus a realistic description for the skyrmion is required. Working in the micromagnetic framework, we derive a macrospin description for the skyrmion using the variational principle and then numerically solve for the bound states. It is shown that the existense and properties of these states as a function of skyrmion size, strongly depend on the skyrmion type. Both vortex and hedgehog skyrmions or anti-skyrmions can induce bound states with energies | E | < ΔS . For the hedgehog skyrmion case however, bound state appearance depends on the chirality. Finally, the probability densities in these states are computed and it is demonstrated that the electrons are localized throughout the skyrmion region. Also affiliated with imec, Belgium.

  15. 3D Dynamics of Freshwater Lenses in the Near-Surface Layer of the Tropical Ocean

    NASA Astrophysics Data System (ADS)

    Soloviev, Alexander; Dean, Cayla

    2015-04-01

    Convective rains in the Intertropical Convergence Zone (ITCZ) produce lenses of freshened water on the ocean surface. These lenses are localized in space and typically involve both salinity and temperature anomalies. Due to significant density anomalies, strong pressure gradients develop, which result in lateral spreading of freshwater lenses in a form resembling gravity currents. Gravity currents inherently involve three-dimensional dynamics. As a type of organized structure, gravity currents in the upper layer of the ocean may also interact with, and be shaped by, the ambient oceanic environment and atmospheric conditions. Among the important factors are the background stratification, wind stress, wind/wave mixing and spatially coherent organized motions in the near-surface layer of the ocean. Under certain conditions, a resonant interaction between a propagating freshwater lens and internal waves in the underlying pycnocline (e.g., barrier layer) may develop, whereas interaction with wind stress may produce an asymmetry in the freshwater lens and associated mixing. These two types of interactions working in concert may explain the series of sharp frontal interfaces, which have been observed in association with freshwater lenses during TOGA COARE. In this work, we have conducted a series of numerical experiments using computational fluid dynamics tools. These numerical simulations were designed to elucidate the relationship between vertical mixing and horizontal advection of salinity under various environmental conditions and potential impact on the Aquarius and SMOS satellite image formation. Available near-surface data from field experiments served as a guidance for numerical simulations. The results of this study indicate that 3D dynamics of freshwater lenses are essential within a certain range of wind/wave conditions and the freshwater influx in the surface layer of the ocean.

  16. A global model simulation for 3-D radiative transfer impact on surface hydrology over Sierra Nevada and Rocky Mountains

    DOE PAGESBeta

    Lee, W. -L.; Gu, Y.; Liou, K. N.; Leung, L. R.; Hsu, H. -H.

    2014-12-15

    We investigate 3-D mountain effects on solar flux distributions and their impact on surface hydrology over the Western United States, specifically the Rocky Mountains and Sierra Nevada using CCSM4 (CAM4/CLM4) global model with a 0.23° × 0.31° resolution for simulations over 6 years. In 3-D radiative transfer parameterization, we have updated surface topography data from a resolution of 1 km to 90 m to improve parameterization accuracy. In addition, we have also modified the upward-flux deviation [3-D - PP (plane-parallel)] adjustment to ensure that energy balance at the surface is conserved in global climate simulations based on 3-D radiation parameterization.more » We show that deviations of the net surface fluxes are not only affected by 3-D mountains, but also influenced by feedbacks of cloud and snow in association with the long-term simulations. Deviations in sensible heat and surface temperature generally follow the patterns of net surface solar flux. The monthly snow water equivalent (SWE) deviations show an increase in lower elevations due to reduced snowmelt, leading to a reduction in cumulative runoff. Over higher elevation areas, negative SWE deviations are found because of increased solar radiation available at the surface. Simulated precipitation increases for lower elevations, while decreases for higher elevations with a minimum in April. Liquid runoff significantly decreases in higher elevations after April due to reduced SWE and precipitation.« less

  17. A global model simulation for 3-D radiative transfer impact on surface hydrology over Sierra Nevada and Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Lee, W.-L.; Gu, Y.; Liou, K. N.; Leung, L. R.; Hsu, H.-H.

    2014-12-01

    We investigate 3-D mountain effects on solar flux distributions and their impact on surface hydrology over the Western United States, specifically the Rocky Mountains and Sierra Nevada using CCSM4 (CAM4/CLM4) global model with a 0.23° × 0.31° resolution for simulations over 6 years. In 3-D radiative transfer parameterization, we have updated surface topography data from a resolution of 1 km to 90 m to improve parameterization accuracy. In addition, we have also modified the upward-flux deviation [3-D - PP (plane-parallel)] adjustment to ensure that energy balance at the surface is conserved in global climate simulations based on 3-D radiation parameterization. We show that deviations of the net surface fluxes are not only affected by 3-D mountains, but also influenced by feedbacks of cloud and snow in association with the long-term simulations. Deviations in sensible heat and surface temperature generally follow the patterns of net surface solar flux. The monthly snow water equivalent (SWE) deviations show an increase in lower elevations due to reduced snowmelt, leading to a reduction in cumulative runoff. Over higher elevation areas, negative SWE deviations are found because of increased solar radiation available at the surface. Simulated precipitation increases for lower elevations, while decreases for higher elevations with a minimum in April. Liquid runoff significantly decreases in higher elevations after April due to reduced SWE and precipitation.

  18. Q AS A LITHOLOGICAL/HYDROCARBON INDICATOR: FROM FULL WAVEFORM SONIC TO 3D SURFACE SEISMIC

    SciTech Connect

    Jorge O. Parra; C.L. Hackert; L. Wilson; H.A. Collier; J. Todd Thomas

    2006-03-31

    The goal of this project was to develop a method to exploit viscoelastic rock and fluid properties to greatly enhance the sensitivity of surface seismic measurements to the presence of hydrocarbon saturation. To reach the objective, Southwest Research Institute scientists used well log, lithology, production, and 3D seismic data from an oil reservoir located on the Waggoner Ranch in north central Texas. The project was organized in three phases. In the first phase, we applied modeling techniques to investigate seismic- and acoustic-frequency wave attenuation and its effect on observable wave attributes. We also gathered existing data and acquired new data from the Waggoner Ranch field, so that all needed information was in place for the second phase. During the second phase, we developed methods to extract attenuation from borehole acoustic and surface seismic data. These methods were tested on synthetic data constructed from realistic models and real data. In the third and final phase of the project, we applied this technology to a full data set from the Waggoner site. The results presented in this Final Report show that geological conditions at the site did not allow us to obtain interpretable results from the Q processing algorithm for 3D seismic data. However, the Q-log processing algorithm was successfully applied to full waveform sonic data from the Waggoner site. A significant part of this project was technology transfer. We have published several papers and conducted presentations at professional conferences. In particular, we presented the Q-log algorithm and applications at the Society of Exploration Geophysicists (SEG) Development and Production Forum in Austin, Texas, in May 2005. The presentation attracted significant interest from the attendees and, at the request of the SEG delegates, it was placed on the Southwest Research Institute Internet site. The presentation can be obtained from the following link: http://www.swri.org/4org/d15/elecsys

  19. WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

    SciTech Connect

    Poulin, E; Racine, E; Beaulieu, L; Binnekamp, D

    2014-06-15

    Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

  20. 3d-shell contribution to the energy loss of protons during grazing scattering from Cu(111) surfaces

    SciTech Connect

    Gravielle, M. S.; Alducin, M.; Juaristi, J. I.; Silkin, V. M.

    2007-10-15

    Motivated by a recent experimental work [S. Lederer and H. Winter, Phys. Rev. A 73, 054901 (2006)] we study the contribution of the 3d shell electrons to the energy loss of 100 keV protons scattered off from the Cu(111) surface. To describe this process we use a multiple collision formalism, where the interaction of the projectile with 3d electrons is described by means of a sequence of single encounters with atoms belonging to the first atomic layer. In order to compare the theoretical energy loss with the experimental data, we add the contribution of valence electrons, which is evaluated in linear response theory using a response function that incorporates information on the surface band structure. For completeness, the energy lost by protons is also calculated within a jellium model that includes 3d and valence electrons with equal footing. Fair agreement between theory and experiment exists when the 3d shell is taken into account in the calculation.

  1. Straightforward reconstruction of 3D surfaces and topography with a camera: Accuracy and geoscience application

    NASA Astrophysics Data System (ADS)

    James, M. R.; Robson, S.

    2012-09-01

    Topographic measurements for detailed studies of processes such as erosion or mass movement are usually acquired by expensive laser scanners or rigorous photogrammetry. Here, we test and use an alternative technique based on freely available computer vision software which allows general geoscientists to easily create accurate 3D models from field photographs taken with a consumer-grade camera. The approach integrates structure-from-motion (SfM) and multiview-stereo (MVS) algorithms and, in contrast to traditional photogrammetry techniques, it requires little expertise and few control measurements, and processing is automated. To assess the precision of the results, we compare SfM-MVS models spanning spatial scales of centimeters (a hand sample) to kilometers (the summit craters of Piton de la Fournaise volcano) with data acquired from laser scanning and formal close-range photogrammetry. The relative precision ratio achieved by SfM-MVS (measurement precision: observation distance) is limited by the straightforward camera calibration model used in the software, but generally exceeds 1:1000 (i.e., centimeter-level precision over measurement distances of 10 s of meters). We apply SfM-MVS at an intermediate scale, to determine erosion rates along a ˜50-m-long coastal cliff. Seven surveys carried out over a year indicate an average retreat rate of 0.70 ± 0.05 m a-1. Sequential erosion maps (at ˜0.05 m grid resolution) highlight the spatiotemporal variability in the retreat, with semivariogram analysis indicating a correlation between volume loss and length scale. Compared with a laser scanner survey of the same site, SfM-MVS produced comparable data and reduced data collection time by ˜80%.

  2. A Global Model Simulation for 3-D Radiative Transfer Impact on Surface Hydrology over Sierra Nevada and Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Lee, W. L.; Gu, Y.; Liou, K. N.; Leung, L. R.; Hsu, H. H.

    2014-12-01

    We investigate 3-D mountain effects on solar flux distributions and their impact on surface hydrology over the Western United States, specifically the Rocky Mountains and Sierra-Nevada using the CCSM4 (CAM4/CLM) global model with a 0.25 degree resolution for a 6-year climate run. In 3-D radiative transfer parameterization, we have updated surface topography data from a resolution of 1 km to 90 meters using the Shuttle Radar Topography Mission (SRTM) global dataset to improve parameterization accuracy. In addition, we have also modified the upward-flux deviation (3D - PP) adjustment to ensure that energy balance at the top of the atmosphere is conserved in climate simulations involving the 3-D radiation parameterization in a global model. We show that deviations of the net surface fluxes are not only affected by 3-D mountains, but also influenced by cloud feedback in association with the long-term simulations. Deviations in sensible heat and surface temperature generally follow the patterns of net surface solar flux. The monthly SWE deviations averaged over the entire domain show an increase in lower elevations due to reduced snowmelt, leading to a reduction in cumulative runoff. Over higher elevation areas, negative SWE deviations are found because of increased solar radiation available at the surface. Simulated precipitation increases for lower elevations, while decreases for higher elevations with a minimum in April. Liquid runoff significantly decreases in higher elevations after April due to reduced SWE and precipitation.

  3. SABAE-HW3D: a Meteor-Hydrological Model Coupling the Land Surface to Groundwater Flow

    NASA Astrophysics Data System (ADS)

    Loukili, Y.; Woodbury, A. D.

    2007-12-01

    A new coupled model linking the land surface scheme SABAE-HW with the saturated groundwater flow is introduced. SABAE-HW stands for: Soil Atmosphere Boundary, Accurate Evaluations of Heat and Water. It was presented (Loukili et al., 2007) as a parallel extension to the Canadian LAnd Surface Scheme (CLASS) which permits a free choice of soil column depth and layers. This development is important as it allows for the coupling of the atmosphere, land surface and subsurface zones. The generic domain under study is subdivided into soil columns whose surface areas represent GCM grid squares. The depths of columns extend to the saturated zone where a water table lower boundary condition is prescribed. In each column the unsaturated flow is forced by the corresponding meteorological data, and the moisture (liquid and frozen) and temperature profiles are computed by SABAE-HW using the half hour time step. The horizontal flow in the saturated zone is described by the vertically integrated model incorporating a storage term, and discretized using a finite volume scheme operating on the same GCM quadrilateral mesh. Since the saturated flow model affords larger time steps, bottom drainages from soil columns are summed up and input as cell recharges. Meanwhile, as the water table fluctuates, the individual column's mesh is allowed to deform. This physically based coupling strategy was selected for its superiority in providing stable and consistent results. In fact, the convergence to steady state situations in both the unsaturated and saturated zones is realized in many validation numerical tests. Moreover, our SABAE-HW3D code was successfully benchmarked against the finite element code Seep/W (Geo-Slope International, 2002) for steady and transient groundwater flows through different soil types. Even when handling coarse grids, SABAE-HW3D solutions are free of moisture oscillation and under or overshoot near the water table. The model is used to understand and assess properly

  4. 3D printed glass: surface finish and bulk properties as a function of the printing process

    NASA Astrophysics Data System (ADS)

    Klein, Susanne; Avery, Michael P.; Richardson, Robert; Bartlett, Paul; Frei, Regina; Simske, Steven

    2015-03-01

    It is impossible to print glass directly from a melt, layer by layer. Glass is not only very sensitive to temperature gradients between different layers but also to the cooling process. To achieve a glass state the melt, has to be cooled rapidly to avoid crystallization of the material and then annealed to remove cooling induced stress. In 3D-printing of glass the objects are shaped at room temperature and then fired. The material properties of the final objects are crucially dependent on the frit size of the glass powder used during shaping, the chemical formula of the binder and the firing procedure. For frit sizes below 250 μm, we seem to find a constant volume of pores of less than 5%. Decreasing frit size leads to an increase in the number of pores which then leads to an increase of opacity. The two different binders, 2- hydroxyethyl cellulose and carboxymethylcellulose sodium salt, generate very different porosities. The porosity of samples with 2-hydroxyethyl cellulose is similar to frit-only samples, whereas carboxymethylcellulose sodium salt creates a glass foam. The surface finish is determined by the material the glass comes into contact with during firing.

  5. Linearly perturbed MHD equilibria and 3D eddy current coupling via the control surface method

    NASA Astrophysics Data System (ADS)

    Portone, A.; Villone, F.; Liu, Y.; Albanese, R.; Rubinacci, G.

    2008-08-01

    In this paper, a coupling strategy based on the control surface concept is used to self-consistently couple linear MHD solvers to 3D codes for the eddy current computation of eddy currents in the metallic structures surrounding the plasma. The coupling is performed by assuming that the plasma inertia (and, with it, all Alfven wave-like phenomena) can be neglected on the time scale of interest, which is dictated by the relevant electromagnetic time of the metallic structures. As is shown, plasma coupling with the metallic structures results in perturbations to the inductance matrix operator. In particular, by adopting the Fourier decomposition in poloidal and toroidal modes, it turns out that each toroidal mode can be associated with a matrix (additively) perturbing the inductance matrix that commonly describes the magnetic coupling of currents in vacuum. In this way, the treatment of resistive wall modes instabilities of various toroidal mode numbers and their possible cross-talk through the currents induced in the metallic structures can be easily studied.

  6. The systematic and random errors determination using realtime 3D surface tracking system in breast cancer

    NASA Astrophysics Data System (ADS)

    Kanphet, J.; Suriyapee, S.; Dumrongkijudom, N.; Sanghangthum, T.; Kumkhwao, J.; Wisetrintong, M.

    2016-03-01

    The purpose of this study to determine the patient setup uncertainties in deep inspiration breath-hold (DIBH) radiation therapy for left breast cancer patients using real-time 3D surface tracking system. The six breast cancer patients treated by 6 MV photon beams from TrueBeam linear accelerator were selected. The patient setup errors and motion during treatment were observed and calculated for interfraction and intrafraction motions. The systematic and random errors were calculated in vertical, longitudinal and lateral directions. From 180 images tracking before and during treatment, the maximum systematic error of interfraction and intrafraction motions were 0.56 mm and 0.23 mm, the maximum random error of interfraction and intrafraction motions were 1.18 mm and 0.53 mm, respectively. The interfraction was more pronounce than the intrafraction, while the systematic error was less impact than random error. In conclusion the intrafraction motion error from patient setup uncertainty is about half of interfraction motion error, which is less impact due to the stability in organ movement from DIBH. The systematic reproducibility is also half of random error because of the high efficiency of modern linac machine that can reduce the systematic uncertainty effectively, while the random errors is uncontrollable.

  7. A new method for automated discontinuity trace mapping on rock mass 3D surface model

    NASA Astrophysics Data System (ADS)

    Li, Xiaojun; Chen, Jianqin; Zhu, Hehua

    2016-04-01

    This paper presents an automated discontinuity trace mapping method on a 3D surface model of rock mass. Feature points of discontinuity traces are first detected using the Normal Tensor Voting Theory, which is robust to noisy point cloud data. Discontinuity traces are then extracted from feature points in four steps: (1) trace feature point grouping, (2) trace segment growth, (3) trace segment connection, and (4) redundant trace segment removal. A sensitivity analysis is conducted to identify optimal values for the parameters used in the proposed method. The optimal triangular mesh element size is between 5 cm and 6 cm; the angle threshold in the trace segment growth step is between 70° and 90°; the angle threshold in the trace segment connection step is between 50° and 70°, and the distance threshold should be at least 15 times the mean triangular mesh element size. The method is applied to the excavation face trace mapping of a drill-and-blast tunnel. The results show that the proposed discontinuity trace mapping method is fast and effective and could be used as a supplement to traditional direct measurement of discontinuity traces.

  8. Accurate electronic and chemical properties of 3d transition metal oxides using a calculated linear response U and a DFT + U(V) method

    NASA Astrophysics Data System (ADS)

    Xu, Zhongnan; Joshi, Yogesh V.; Raman, Sumathy; Kitchin, John R.

    2015-04-01

    We validate the usage of the calculated, linear response Hubbard U for evaluating accurate electronic and chemical properties of bulk 3d transition metal oxides. We find calculated values of U lead to improved band gaps. For the evaluation of accurate reaction energies, we first identify and eliminate contributions to the reaction energies of bulk systems due only to changes in U and construct a thermodynamic cycle that references the total energies of unique U systems to a common point using a DFT + U(V ) method, which we recast from a recently introduced DFT + U(R) method for molecular systems. We then introduce a semi-empirical method based on weighted DFT/DFT + U cohesive energies to calculate bulk oxidation energies of transition metal oxides using density functional theory and linear response calculated U values. We validate this method by calculating 14 reactions energies involving V, Cr, Mn, Fe, and Co oxides. We find up to an 85% reduction of the mean average error (MAE) compared to energies calculated with the Perdew-Burke-Ernzerhof functional. When our method is compared with DFT + U with empirically derived U values and the HSE06 hybrid functional, we find up to 65% and 39% reductions in the MAE, respectively.

  9. Accurate electronic and chemical properties of 3d transition metal oxides using a calculated linear response U and a DFT + U(V) method

    SciTech Connect

    Xu, Zhongnan; Kitchin, John R.; Joshi, Yogesh V.; Raman, Sumathy

    2015-04-14

    We validate the usage of the calculated, linear response Hubbard U for evaluating accurate electronic and chemical properties of bulk 3d transition metal oxides. We find calculated values of U lead to improved band gaps. For the evaluation of accurate reaction energies, we first identify and eliminate contributions to the reaction energies of bulk systems due only to changes in U and construct a thermodynamic cycle that references the total energies of unique U systems to a common point using a DFT + U(V ) method, which we recast from a recently introduced DFT + U(R) method for molecular systems. We then introduce a semi-empirical method based on weighted DFT/DFT + U cohesive energies to calculate bulk oxidation energies of transition metal oxides using density functional theory and linear response calculated U values. We validate this method by calculating 14 reactions energies involving V, Cr, Mn, Fe, and Co oxides. We find up to an 85% reduction of the mean average error (MAE) compared to energies calculated with the Perdew-Burke-Ernzerhof functional. When our method is compared with DFT + U with empirically derived U values and the HSE06 hybrid functional, we find up to 65% and 39% reductions in the MAE, respectively.

  10. Characterizing interstate vibrational coherent dynamics of surface adsorbed catalysts by fourth-order 3D SFG spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Yingmin; Wang, Jiaxi; Clark, Melissa L.; Kubiak, Clifford P.; Xiong, Wei

    2016-04-01

    We report the first fourth-order 3D SFG spectroscopy of a monolayer of the catalyst Re(diCN-bpy)(CO)3Cl on a gold surface. Besides measuring the vibrational coherences of single vibrational modes, the fourth-order 3D SFG spectrum also measures the dynamics of interstate coherences and vibrational coherences states between two vibrational modes. By comparing the 3D SFG to the corresponding 2D and third-order 3D IR spectroscopy of the same molecules in solution, we found that the interstate coherences exist in both liquid and surface systems, suggesting that the interstate coherence is not disrupted by surface interactions. However, by analyzing the 3D spectral lineshape, we found that the interstate coherences also experience non-negligible homogenous dephasing dynamics that originate from surface interactions. This unique ability of determining interstate vibrational coherence dynamics of the molecular monolayer can help in understanding of how energy flows within surface catalysts and other molecular monolayers.

  11. Optimizing an SEM-based 3D surface imaging technique for recording bond coat surface geometry in thermal barrier coatings

    NASA Astrophysics Data System (ADS)

    Shahbazmohamadi, Sina; Jordan, Eric H.

    2012-12-01

    Creation of three-dimensional representations of surfaces from images taken at two or more view angles is a well-established technique applied to optical images and is frequently used in combination with scanning electron microscopy (SEM). The present work describes specific steps taken to optimize and enhance the repeatability of three-dimensional surfaces reconstructed from SEM images. The presented steps result in an approximately tenfold improvement in the repeatability of the surface reconstruction compared to more standard techniques. The enhanced techniques presented can be used with any SEM friendly samples. In this work the modified technique was developed in order to accurately quantify surface geometry changes in metallic bond coats used with thermal barrier coatings (TBCs) to provide improved turbine hot part durability. Bond coat surfaces are quite rough, and accurate determination of surface geometry change (rumpling) requires excellent repeatability. Rumpling is an important contributor to TBC failure, and accurate quantification of rumpling is important to better understanding of the failure behavior of TBCs.

  12. SU-E-T-04: 3D Printed Patient-Specific Surface Mould Applicators for Brachytherapy Treatment of Superficial Lesions

    SciTech Connect

    Cumming, I; Lasso, A; Rankin, A; Fichtinger, G; Joshi, C P; Falkson, C; Schreiner, L John

    2014-06-01

    Purpose: Evaluate the feasibility of constructing 3D-printed patient-specific surface mould applicators for HDR brachytherapy treatment of superficial lesions. Methods: We propose using computer-aided design software to create 3D printed surface mould applicators for brachytherapy. A mould generation module was developed in the open-source 3D Slicer ( http://www.slicer.org ) medical image analysis platform. The system extracts the skin surface from CT images, and generates smooth catheter paths over the region of interest based on user-defined start and end points at a specified stand-off distance from the skin surface. The catheter paths are radially extended to create catheter channels that are sufficiently wide to ensure smooth insertion of catheters for a safe source travel. An outer mould surface is generated to encompass the channels. The mould is also equipped with fiducial markers to ensure its reproducible placement. A surface mould applicator with eight parallel catheter channels of 4mm diameters was fabricated for the nose region of a head phantom; flexible plastic catheters of 2mm diameter were threaded through these channels maintaining 10mm catheter separations and a 5mm stand-off distance from the skin surface. The apparatus yielded 3mm thickness of mould material between channels and the skin. The mould design was exported as a stereolithography file to a Dimension SST1200es 3D printer and printed using ABS Plus plastic material. Results: The applicator closely matched its design and was found to be sufficiently rigid without deformation during repeated application on the head phantom. Catheters were easily threaded into channels carved along catheter paths. Further tests are required to evaluate feasibility of channel diameters smaller than 4mm. Conclusion: Construction of 3D-printed mould applicators show promise for use in patient specific brachytherapy of superficial lesions. Further evaluation of 3D printing techniques and materials is required

  13. Surface amplitude data: 3D-seismic for interpretation of sea floor geology (Louisiana Slope)

    SciTech Connect

    Roberts, H.H.

    1996-09-01

    Proliferation of 3D-seismic in support of hydrocarbon exploration/production has created new data for improved interpretation of sea floor and shallow subsurface geology. Processing of digital seismic data to enhance amplitude anomalies produces information for improved assessment of geohazards and identification of sensitive benthic communities protected by environmental regulations. Coupled with high resolution acoustic data and direct observation/sampling using a manned research submersible, surface amplitude maps add critical interpretive information for identification of sea floor features. Non-reflective zones (acoustic wipeouts) are associated with many slope features. Mud diapirs, mud mounds, mud volcanoes, gas-changed sediments, gas hydrates, slump deposits, carbonate hardgrounds, and various types of carbonate mounds are all features that exhibit this common response on high resolution seismic profiles. Amplitude data help make specific identifications. Since 1988, submersible data from mid-to-upper slope features (Garden Banks, Green Canyon, and Mississippi Canyon lease block areas) have been analyzed with conventional high resolution acoustic data and 313-amplitude extraction maps. Areas of rapid venting of sediment and hydrocarbon-charged formation fluids are clearly distinguishable from mud diapirs and areas of carbonate mounds (slow seepage). Gas hydrates occur as mounds and mounded zones along faults; products of moderate flux rates below (approx.) 500 in water depths. Gas hydrates function as stored trophic resources that support sensitive chemosynthetic communities. Amplitude extraction maps clearly identify these features by a strong low impedance amplitude anomaly. Refinement and {open_quotes}field calibration{close_quotes} of the surface amplitude extraction method may eventually lead to a new standard for evaluating geohazards and sensitive benthic communities.

  14. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    NASA Astrophysics Data System (ADS)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  15. Visualization of Buffer Capacity with 3-D "Topo" Surfaces: Buffer Ridges, Equivalence Point Canyons and Dilution Ramps

    ERIC Educational Resources Information Center

    Smith, Garon C.; Hossain, Md Mainul

    2016-01-01

    BufCap TOPOS is free software that generates 3-D topographical surfaces ("topos") for acid-base equilibrium studies. It portrays pH and buffer capacity behavior during titration and dilution procedures. Topo surfaces are created by plotting computed pH and buffer capacity values above a composition grid with volume of NaOH as the x axis…

  16. 3D geomodelling combining implicit surfaces and Voronoi-based remeshing: A case study in the Lorraine Coal Basin (France)

    NASA Astrophysics Data System (ADS)

    Collon, Pauline; Steckiewicz-Laurent, Wendy; Pellerin, Jeanne; Laurent, Gautier; Caumon, Guillaume; Reichart, Guillaume; Vaute, Laurent

    2015-04-01

    In this paper we demonstrate how recent geomodelling techniques can be combined and used to build a 3D geological model on a real case study: the former coal mine of Merlebach (France), that is targeted to be exploited for low-temperature geothermal energy production. From geological maps, cross-sections, borehole and mine exploitation data, we build a 3D model in which are identified the rocks and infrastructures having significantly different permeabilities. First, a structural model of the main geological interfaces in our area of interest (2 horizons and 13 faults) is built with classical geomodelling techniques. Then, we propose to model by surfaces the 71 irregularly stacked, very close and very thin, sub-vertical coal beds. To ease their construction, we use an implicit method which represents 3D surfaces as isovalues of a scalar field defined in a 3D tetrahedral grid of the area. The corresponding triangulated surfaces are remeshed with a recently proposed method based on Voronoi diagrams so that the exploited parts of the coal beds, now filled by sand, can be computed. The 3D surface-based geological model, in which infrastructures can be inserted as piecewise lines, can be volumetrically meshed. It is available for download as supplemental material, as well as a volumetric grid.

  17. 3D surface measurement for medical application--technical comparison of two established industrial surface scanning systems.

    PubMed

    Schwenzer-Zimmerer, K; Haberstok, J; Kovacs, L; Boerner, B I; Schwenzer, N; Juergens, P; Zeihofer, H F; Holberg, C

    2008-02-01

    In 3D mapping of flexible surfaces (e.g. human faces) measurement errors due to movement or positioning occur. Aggravated by equipment- or researcher-caused mistakes considerable deviations can result. Therefore first the appliances' precision handling and reliability in clinical environment must be established. Aim of this study was to investigate accuracy and precision of two contact-free 3D measurement systems (white light vs. laser). Standard specimens of known diameter for sphere deviation, touch deviation and plane deviation were tested. Both systems are appropriate for medical application acquiring solid data (

  18. 3D surface-wave tomography in the central Baltic Shield

    NASA Astrophysics Data System (ADS)

    Bruneton, M.; Pedersen, H. A.; Farra, V.; Svekalapko Seismic Tomography Working Group

    2003-04-01

    The main objective of the SVEKALAPKO deep seismic experiment was to image in details the lithosphere-asthenosphere system of the central Baltic Shield, therefore enhancing our knowledge of the structure and evolution of cratonic lithosphere. During the experiment a regular 2D grid of 46 broad-band stations covered the southern part of Finland. This exceptional stations distribution made it possible to undertake a high precision surface-wave tomography. We developed a technique based on paraxial ray tracing to obtain 2D phase-velocity maps as a function of frequency which can subsequently be inverted for the 3D structure. The major improvement is that we jointly inverted for the velocity model under the array and the shape of incoming wave fronts, therefore reducing artifacts due to structure outside the study region. The data set included carefully selected fundamental mode Rayleigh wave arrival times of 69 teleseismic events, computed using Wiener filtering. An average dispersion curve was obtained imposing the phase-velocity to be quasi constant. It leads to shear-wave velocities for the lithospheric mantle 4% faster than standard Earth model ak135. The inversion of the same data set was also conducted using weaker constraints to obtain the lateral variations of the phase-velocity at each frequency and subsequently of the shear-wave velocity as a function of depth. Three Vs profiles were computed respectively in the Karelian Archean province, in the Proterozoic Svekofennia, and at the suture between the two domains. They showed significant variations, the higher lithospheric velocities were seen in the proterozoic domain, a low velocity zone was necessary only in the suture zone. Our results showed that chemical changes are maintained within the lithosphere over extended periods of time.

  19. Importance of 3D Processes Near the Ocean's Surface for Material Transport

    NASA Astrophysics Data System (ADS)

    Ozgokmen, T. M.

    2014-12-01

    There are a number of practical problems that demand an accurate knowledge of ocean currents near the surface of the ocean. It is known that oceanic coherent features transport heat and carry out vertical exchange of biogeochemical tracers. Ocean currents can affect biological primary production, air-sea gas exchanges and global tracer budgets. Ocean currents are also important for the dispersion of substances that pose a danger to society, economy and human health. Examples of such events include algal blooms, the Fukushima nuclear plant incident in the Pacific Ocean in 2011, and repeated large oil spills in the Gulf of Mexico, namely the IXTOC in 1978 and the Deepwater Horizon event in 2010. Such incidents demand accurate answers to questions such as ``where will the pollutant go?", ``how fast will it get there?" and ``how much pollutant will arrive there?", and in some instances ``where did the pollutant come from?". The answers to these questions are critical to the allocation of limited response resources, and in determining the overall impact of the events. We will summarize the efforts by the Consortium for Advanced Research on Transport of Hydrocarbon in the Environment (CARTHE). One of the primary objectives of CARTHE is to improve predictive modeling capability for flows near the air-sea interface. In particular, two large experiments, Grand Lagrangian Deployment (GLAD) and Surf-zone and Coastal Oil Pathways Experiment (SCOPE), coordinated with real-time modeling were instructive on processes influencing near-surface material transport. Findings on submesoscale flows as well as model deficiencies to capture processes relevant to transport will be discussed. Insight into future modeling and observational plans will be provided.

  20. Analysis of surface cracks at hole by a 3-D weight function method with stresses from finite element method

    NASA Technical Reports Server (NTRS)

    Zhao, W.; Newman, J. C., Jr.; Sutton, M. A.; Shivakumar, K. N.; Wu, X. R.

    1995-01-01

    Parallel with the work in Part-1, stress intensity factors for semi-elliptical surface cracks emanating from a circular hole are determined. The 3-D weight function method with the 3D finite element solutions for the uncracked stress distribution as in Part-1 is used for the analysis. Two different loading conditions, i.e. remote tension and wedge loading, are considered for a wide range in geometrical parameters. Both single and double surface cracks are studied and compared with other solutions available in the literature. Typical crack opening displacements are also provided.

  1. User's manual for FRAC3D: Supplement to report on stress analysis for structures with surface cracks

    NASA Technical Reports Server (NTRS)

    Bell, J. C.; Hopper, A. T.; Hayes, P. A.

    1978-01-01

    The FRAC3D computer program, designed for use in analyzing stresses in structures (including plates, bars, or blocks) which may contain part-circular surface cracks or embedded circular cracks is described. Instructions are provided for preparing input, including that for the supporting programs LATTICE and MATSOL as well as for FRAC3D. The course of a substantial illustrative calculation is shown with both input and output. The formulas underlying the calculations are summarized and related to the subroutines in which they are used. Many issues of strategy in using this program for analysing stresses around surface cracks are elucidated.

  2. The "Pure Marriage" between 3D Printing and Well-Ordered Nanoarrays by Using PEALD Assisted Hydrothermal Surface Engineering.

    PubMed

    Xue, Chaowen; Shi, Xiaotong; Fang, Xuan; Tao, Haiyan; Zhu, Hui; Yu, Fen; Ding, Xingwei; Liu, Miaoxing; Fang, Fang; Yang, Fan; Wei, Zhipeng; Chen, Tingtao; Wang, Zongliang; Wang, Guoping; Cheng, Xigao; Wei, Junchao; Lin, Yingjie; Deng, Keyu; Wang, Xiaolei; Xin, Hongbo

    2016-04-01

    For the first time, homogeneous and well-ordered functional nanoarrays were grown densely on the complex structured three-dimensional (3D) printing frameworks through a general plasma enhanced atomic layer deposition (PEALD) assisted hydrothermal surface engineering process. The entire process was free from toxic additives or harmful residues and, therefore, can meet the critical requirements of high-purity products. As a practical example, 3D customized earplugs were precisely manufactured according to the model of ear canals at the 0.1 mm level. Meanwhile, well-ordered ZnO nanoarrays, formed on the surfaces of these 3D printed earplugs, could effectively prevent the growth of five main pathogens derived from the patients with otitis media and exhibited excellent wear resistance as well. On the basis of both animal experiments and volunteers' investigations, the 3D customized earplugs showed sound insulation capabilities superior to those of traditional earplugs. Further animal experiments demonstrated the potential of as-modified implant scaffolds in practical clinical applications. This work, exemplified with earplugs and implant scaffolds, oriented the development direction of 3D printing in biomedical devices, which precisely integrated customized architecture and tailored surface performance. PMID:26974545

  3. Novel 3D imaging techniques for improved understanding of planetary surface geomorphology.

    NASA Astrophysics Data System (ADS)

    Muller, Jan-Peter

    2015-04-01

    Understanding the role of different planetary surface formation processes within our Solar System is one of the fundamental goals of planetary science research. There has been a revolution in planetary surface observations over the past decade for Mars and the Moon, especially in 3D imaging of surface shape (down to resolutions of 75cm) and subsequent correction for terrain relief of imagery from orbiting and co-registration of lander and rover robotic images. We present some of the recent highlights including 3D modelling of surface shape from the ESA Mars Express HRSC (High Resolution Stereo Camera), see [1], [2] at 30-100m grid-spacing; and then co-registered to HRSC using a resolution cascade of 20m DTMs from NASA MRO stereo-CTX and 0.75m DTMs from MRO stereo-HiRISE [3]. This has opened our eyes to the formation mechanisms of megaflooding events, such as the formation of Iani Vallis and the upstream blocky terrain, to crater lakes and receding valley cuts [4]. A comparable set of products is now available for the Moon from LROC-WA at 100m [5] and LROC-NA at 1m [6]. Recently, a very novel technique for the super-resolution restoration (SRR) of stacks of images has been developed at UCL [7]. First examples shown will be of the entire MER-A Spirit rover traverse taking a stack of 25cm HiRISE to generate a corridor of SRR images along the rover traverse of 5cm imagery of unresolved features such as rocks, created as a consequence of meteoritic bombardment, ridge and valley features. This SRR technique will allow us for ˜400 areas on Mars (where 5 or more HiRISE images have been captured) and similar numbers on the Moon to resolve sub-pixel features. Examples will be shown of how these SRR images can be employed to assist with the better understanding of surface geomorphology. Acknowledgements: The research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under PRoViDE grant agreement n° 312377

  4. 3D surface roughness recreation and data processing of granitic rocks and claystones, potential host rocks for radioactive waste disposal

    NASA Astrophysics Data System (ADS)

    Buocz, Ildikó; Török, Ákos; Rozgonyi-Boissinot, Nikoletta

    2015-04-01

    The determination and modelling of the stability of rock slopes, tunnels, or underground spaces, i.e. radioactive waste disposal facilities, is an important task in engineering. The appropriate estimation of the mechanical parameters for a realistic description of the behaviour of rocks results in higher safety and more economic design. The failure of stability is primarily due to the shear failure of the rock masses along fractures and joints: therefore the correct determination of the shear strength is crucial. One of the most important parameters influencing the shear strength along rock joints is their surface roughness. Although the quantification of surface roughness has been an open question during the past century, several attempts have been made, starting with 2D and continuing with 3D measurements, to provide engineers with a method for determining shear strength numerically. As technology evolved, the 3D methods became more popular and several scientists started to investigate the surface properties through laser scanning and different photogrammetrical methods. This paper shows a photogrammetric method for the 3D digital recreation of joint surfaces of granitic rock and claystone, both potential host rocks for radioactive waste disposal. The rocks derived from Bátaapáti (South Hungary) and Mont Terri (North Switzerland) respectively. The samples are laboratory scaled specimens with an areal size of 50x50 mm. The software used is called ShapeMetrix3D, developed by 3GSM GmbH in Austria. The major steps of the creation of the 3D picture are presented, as well as the following data processing which leads to the quantification of the 3D surface roughness.

  5. On the evaluation of photogrammetric methods for dense 3D surface reconstruction in a metrological context

    NASA Astrophysics Data System (ADS)

    Toschi, I.; Capra, A.; De Luca, L.; Beraldin, J.-A.; Cournoyer, L.

    2014-05-01

    This paper discusses a methodology to evaluate the accuracy of recently developed image-based 3D modelling techniques. So far, the emergence of these novel methods has not been supported by the definition of an internationally recognized standard which is fundamental for user confidence and market growth. In order to provide an element of reflection and solution to the different communities involved in 3D imaging, a promising approach is presented in this paper for the assessment of both metric quality and limitations of an open-source suite of tools (Apero/MicMac), developed for the extraction of dense 3D point clouds from a set of unordered 2D images. The proposed procedural workflow is performed within a metrological context, through inter-comparisons with "reference" data acquired with two hemispherical laser scanners, one total station, and one laser tracker. The methodology is applied to two case studies, designed in order to analyse the software performances in dealing with both outdoor and environmentally controlled conditions, i.e. the main entrance of Cathédrale de la Major (Marseille, France) and a custom-made scene located at National Research Council of Canada 3D imaging Metrology Laboratory (Ottawa). Comparative data and accuracy evidence produced for both tests allow the study of some key factors affecting 3D model accuracy.

  6. Meter-Scale 3-D Models of the Martian Surface from Combining MOC and MOLA Data

    NASA Technical Reports Server (NTRS)

    Soderblom, Laurence A.; Kirk, Randolph L.

    2003-01-01

    We have extended our previous efforts to derive through controlled photoclinometry, accurate, calibrated, high-resolution topographic models of the martian surface. The process involves combining MGS MOLA topographic profiles and MGS MOC Narrow Angle images. The earlier work utilized, along with a particular MOC NA image, the MOLA topographic profile that was acquired simultaneously, in order to derive photometric and scattering properties of the surface and atmosphere so as to force the low spatial frequencies of a one-dimensional MOC photoclinometric model to match the MOLA profile. Both that work and the new results reported here depend heavily on successful efforts to: 1) refine the radiometric calibration of MOC NA; 2) register the MOC to MOLA coordinate systems and refine the pointing; and 3) provide the ability to project into a common coordinate system, simultaneously acquired MOC and MOLA with a single set of SPICE kernels utilizing the USGS ISIS cartographic image processing tools. The approach described in this paper extends the MOC-MOLA integration and cross-calibration procedures from one-dimensional profiles to full two-dimensional photoclinometry and image simulations. Included are methods to account for low-frequency albedo variations within the scene.

  7. Adapting Data Processing To Compare Model and Experiment Accurately: A Discrete Element Model and Magnetic Resonance Measurements of a 3D Cylindrical Fluidized Bed.

    PubMed

    Boyce, Christopher M; Holland, Daniel J; Scott, Stuart A; Dennis, John S

    2013-12-18

    Discrete element modeling is being used increasingly to simulate flow in fluidized beds. These models require complex measurement techniques to provide validation for the approximations inherent in the model. This paper introduces the idea of modeling the experiment to ensure that the validation is accurate. Specifically, a 3D, cylindrical gas-fluidized bed was simulated using a discrete element model (DEM) for particle motion coupled with computational fluid dynamics (CFD) to describe the flow of gas. The results for time-averaged, axial velocity during bubbling fluidization were compared with those from magnetic resonance (MR) experiments made on the bed. The DEM-CFD data were postprocessed with various methods to produce time-averaged velocity maps for comparison with the MR results, including a method which closely matched the pulse sequence and data processing procedure used in the MR experiments. The DEM-CFD results processed with the MR-type time-averaging closely matched experimental MR results, validating the DEM-CFD model. Analysis of different averaging procedures confirmed that MR time-averages of dynamic systems correspond to particle-weighted averaging, rather than frame-weighted averaging, and also demonstrated that the use of Gaussian slices in MR imaging of dynamic systems is valid. PMID:24478537

  8. Adapting Data Processing To Compare Model and Experiment Accurately: A Discrete Element Model and Magnetic Resonance Measurements of a 3D Cylindrical Fluidized Bed

    PubMed Central

    2013-01-01

    Discrete element modeling is being used increasingly to simulate flow in fluidized beds. These models require complex measurement techniques to provide validation for the approximations inherent in the model. This paper introduces the idea of modeling the experiment to ensure that the validation is accurate. Specifically, a 3D, cylindrical gas-fluidized bed was simulated using a discrete element model (DEM) for particle motion coupled with computational fluid dynamics (CFD) to describe the flow of gas. The results for time-averaged, axial velocity during bubbling fluidization were compared with those from magnetic resonance (MR) experiments made on the bed. The DEM-CFD data were postprocessed with various methods to produce time-averaged velocity maps for comparison with the MR results, including a method which closely matched the pulse sequence and data processing procedure used in the MR experiments. The DEM-CFD results processed with the MR-type time-averaging closely matched experimental MR results, validating the DEM-CFD model. Analysis of different averaging procedures confirmed that MR time-averages of dynamic systems correspond to particle-weighted averaging, rather than frame-weighted averaging, and also demonstrated that the use of Gaussian slices in MR imaging of dynamic systems is valid. PMID:24478537

  9. A New Accurate 3D Measurement Tool to Assess the Range of Motion of the Tongue in Oral Cancer Patients: A Standardized Model.

    PubMed

    van Dijk, Simone; van Alphen, Maarten J A; Jacobi, Irene; Smeele, Ludwig E; van der Heijden, Ferdinand; Balm, Alfons J M

    2016-02-01

    In oral cancer treatment, function loss such as speech and swallowing deterioration can be severe, mostly due to reduced lingual mobility. Until now, there is no standardized measurement tool for tongue mobility and pre-operative prediction of function loss is based on expert opinion instead of evidence based insight. The purpose of this study was to assess the reliability of a triple-camera setup for the measurement of tongue range of motion (ROM) in healthy adults and its feasibility in patients with partial glossectomy. A triple-camera setup was used, and 3D coordinates of the tongue in five standardized tongue positions were achieved in 15 healthy volunteers. Maximum distances between the tip of the tongue and the maxillary midline were calculated. Each participant was recorded twice, and each movie was analysed three times by two separate raters. Intrarater, interrater and test-retest reliability were the main outcome measures. Secondly, feasibility of the method was tested in ten patients treated for oral tongue carcinoma. Intrarater, interrater and test-retest reliability all showed high correlation coefficients of >0.9 in both study groups. All healthy subjects showed perfect symmetrical tongue ROM. In patients, significant differences in lateral tongue movements were found, due to restricted tongue mobility after surgery. This triple-camera setup is a reliable measurement tool to assess three-dimensional information of tongue ROM. It constitutes an accurate tool for objective grading of reduced tongue mobility after partial glossectomy. PMID:26516075

  10. Registration of 3D and multispectral data for the study of cultural heritage surfaces.

    PubMed

    Chane, Camille Simon; Schütze, Rainer; Boochs, Frank; Marzani, Franck S

    2013-01-01

    We present a technique for the multi-sensor registration of featureless datasets based on the photogrammetric tracking of the acquisition systems in use. This method is developed for the in situ study of cultural heritage objects and is tested by digitizing a small canvas successively with a 3D digitization system and a multispectral camera while simultaneously tracking the acquisition systems with four cameras and using a cubic target frame with a side length of 500 mm. The achieved tracking accuracy is better than 0.03 mm spatially and 0.150 mrad angularly. This allows us to seamlessly register the 3D acquisitions and to project the multispectral acquisitions on the 3D model. PMID:23322103

  11. A global model simulation for 3-D radiative transfer impact on surface hydrology over the Sierra Nevada and Rocky Mountains

    NASA Astrophysics Data System (ADS)

    Lee, W.-L.; Gu, Y.; Liou, K. N.; Leung, L. R.; Hsu, H.-H.

    2015-05-01

    We investigate 3-D mountain effects on solar flux distributions and their impact on surface hydrology over the western United States, specifically the Rocky Mountains and the Sierra Nevada, using the global CCSM4 (Community Climate System Model version 4; Community Atmosphere Model/Community Land Model - CAM4/CLM4) with a 0.23° x 0.31° resolution for simulations over 6 years. In a 3-D radiative transfer parameterization, we have updated surface topography data from a resolution of 1 km to 90 m to improve parameterization accuracy. In addition, we have also modified the upward-flux deviation (3-D-PP (plane-parallel)) adjustment to ensure that the energy balance at the surface is conserved in global climate simulations based on 3-D radiation parameterization. We show that deviations in the net surface fluxes are not only affected by 3-D mountains but also influenced by feedbacks of cloud and snow in association with the long-term simulations. Deviations in sensible heat and surface temperature generally follow the patterns of net surface solar flux. The monthly snow water equivalent (SWE) deviations show an increase in lower elevations due to reduced snowmelt, leading to a reduction in cumulative runoff. Over higher-elevation areas, negative SWE deviations are found because of increased solar radiation available at the surface. Simulated precipitation increases for lower elevations, while it decreases for higher elevations, with a minimum in April. Liquid runoff significantly decreases at higher elevations after April due to reduced SWE and precipitation.

  12. Reproducibly creating hierarchical 3D carbon to study the effect of Si surface functionalization on the oxygen reduction reaction

    NASA Astrophysics Data System (ADS)

    Zeng, Yuze; Flores, Jose F.; Shao, Yu-Cheng; Guo, Jinghua; Chuang, Yi-De; Lu, Jennifer Q.

    2016-06-01

    We report a new method to reproducibly fabricate functional 3D carbon structures directly on a current collector, e.g. stainless steel. The 3D carbon platform is formed by direct growth of upright arrays of carbon nanofiber bundles on a roughened surface of stainless steel via the seed-assisted approach. Each bundle consists of about 30 individual carbon nanofibers with a diameter of 18 nm on average. We have found that this new platform offers adequate structural integrity. As a result, no reduction of the surface area during downstream chemical functionalization was observed. With a fixed and reproducible 3D structure, the effect of the chemistry of the grafted species on the oxygen reduction reaction has been systematically investigated. This investigation reveals for the first time that non-conductive Si with an appropriate electronic structure distorts the carbon electronic structure and consequently enhances ORR electrocatalysis. The strong interface provides excellent electron connectivity according to electrochemical analysis. This highly reproducible and stable 3D platform can serve as a stepping-stone for the investigation of the effect of carbon surface functionalization on electrochemical reactions in general.We report a new method to reproducibly fabricate functional 3D carbon structures directly on a current collector, e.g. stainless steel. The 3D carbon platform is formed by direct growth of upright arrays of carbon nanofiber bundles on a roughened surface of stainless steel via the seed-assisted approach. Each bundle consists of about 30 individual carbon nanofibers with a diameter of 18 nm on average. We have found that this new platform offers adequate structural integrity. As a result, no reduction of the surface area during downstream chemical functionalization was observed. With a fixed and reproducible 3D structure, the effect of the chemistry of the grafted species on the oxygen reduction reaction has been systematically investigated. This

  13. Obtaining 3d models of surface snow and ice features (penitentes) with a Xbox Kinect

    NASA Astrophysics Data System (ADS)

    Nicholson, Lindsey; Partan, Benjamin; Pętlicki, Michał; MacDonell, Shelley

    2014-05-01

    Penitentes are snow or ice spikes that can reach several metres in height. They are a common feature of snow and ice surfaces in the semi-arid Andes as their formation is favoured by very low humidity, persistently low temperatures and sustained high solar radiation. While the conditions of their formation are relatively well constrained it is not yet clear how their presence influences the rate of mass loss and meltwater production from the mountain cryosphere and there is a need for accurate measurements of ablation within penitente fields through time in order to evaluate how well existing energy balance models perform for surfaces with penitentes. The complex surface morphology poses a challenge to measuring the mass loss at snow or glacier surfaces as (i) the spatial distribution of surface lowering within a penitente field is very heterogeneous, and (ii) the steep walls and sharp edges of the penitentes limit the line of sight view for surveying from fixed positions. In this work we explored whether these problems can be solved by using the Xbox Kinect sensor to generate small scale digital terrain models (DTMs) of sample areas of snow and ice penitentes. The study site was Glaciar Tapado in Chile (30°08'S; 69°55'W) where three sample sites were monitored from November 2013 to January 2014. The range of the Kinect sensor was found to be restricted to about 1 m over snow and ice, and scanning was only possible after dusk. Moving the sensor around the penitente field was challenging and often resulted in fragmented scans. However, despite these challenges, the scans obtained could be successfully combined in MeshLab software to produce good surface representations of the penitentes. GPS locations of target stakes in the sample plots allow the DTMs to be orientated correctly in space so the morphology of the penitente field and the volume loss through time can be fully described. At the study site in snow penitentes the Kinect DTM was compared with the quality

  14. In Situ Fabrication of 3D Ag@ZnO Nanostructures for Microfluidic Surface-Enhanced Raman Scattering Systems

    PubMed Central

    2015-01-01

    In this work, we develop an in situ method to grow highly controllable, sensitive, three-dimensional (3D) surface-enhanced Raman scattering (SERS) substrates via an optothermal effect within microfluidic devices. Implementing this approach, we fabricate SERS substrates composed of Ag@ZnO structures at prescribed locations inside microfluidic channels, sites within which current fabrication of SERS structures has been arduous. Conveniently, properties of the 3D Ag@ZnO nanostructures such as length, packing density, and coverage can also be adjusted by tuning laser irradiation parameters. After exploring the fabrication of the 3D nanostructures, we demonstrate a SERS enhancement factor of up to ∼2 × 106 and investigate the optical properties of the 3D Ag@ZnO structures through finite-difference time-domain simulations. To illustrate the potential value of our technique, low concentrations of biomolecules in the liquid state are detected. Moreover, an integrated cell-trapping function of the 3D Ag@ZnO structures records the surface chemical fingerprint of a living cell. Overall, our optothermal-effect-based fabrication technique offers an effective combination of microfluidics with SERS, resolving problems associated with the fabrication of SERS substrates in microfluidic channels. With its advantages in functionality, simplicity, and sensitivity, the microfluidic-SERS platform presented should be valuable in many biological, biochemical, and biomedical applications. PMID:25402207

  15. Geological interpretation and analysis of surface based, spatially referenced planetary imagery data using PRoGIS 2.0 and Pro3D.

    NASA Astrophysics Data System (ADS)

    Barnes, R.; Gupta, S.; Giordano, M.; Morley, J. G.; Muller, J. P.; Tao, Y.; Sprinks, J.; Traxler, C.; Hesina, G.; Ortner, T.; Sander, K.; Nauschnegg, B.; Paar, G.; Willner, K.; Pajdla, T.

    2015-10-01

    We apply the capabilities of the geospatial environment PRoGIS 2.0 and the real time rendering viewer PRo3D to geological analysis of NASA's Mars Exploration Rover-B (MER-B Opportunity rover) and Mars Science Laboratory (MSL Curiosity rover) datasets. Short baseline and serendipitous long baseline stereo Pancam rover imagery are used to create 3D point clouds which can be combined with super-resolution images derived from Mars Reconnaissance Orbiter HiRISE orbital data, andsuper-resolution outcrop images derived from MER Pancam, as well as hand-lens scale images for geology and outcrop characterization at all scales. Data within the PRoViDE database are presented and accessed through the PRoGIS interface. Simple geological measurement tools are implemented within the PRoGIS and PRo3D web software to accurately measure the dip and strike of bedding in outcrops, create detailed stratigraphic logs for correlation between the areas investigated, and to develop realistic 3D models for the characterization of planetary surface processes. Annotation tools are being developed to aid discussion and dissemination of the observations within the planetary science community.

  16. Structured Light Based 3d Scanning for Specular Surface by the Combination of Gray Code and Phase Shifting

    NASA Astrophysics Data System (ADS)

    Zhang, Yujia; Yilmaz, Alper

    2016-06-01

    Surface reconstruction using coded structured light is considered one of the most reliable techniques for high-quality 3D scanning. With a calibrated projector-camera stereo system, a light pattern is projected onto the scene and imaged by the camera. Correspondences between projected and recovered patterns are computed in the decoding process, which is used to generate 3D point cloud of the surface. However, the indirect illumination effects on the surface, such as subsurface scattering and interreflections, will raise the difficulties in reconstruction. In this paper, we apply maximum min-SW gray code to reduce the indirect illumination effects of the specular surface. We also analysis the errors when comparing the maximum min-SW gray code and the conventional gray code, which justifies that the maximum min-SW gray code has significant superiority to reduce the indirect illumination effects. To achieve sub-pixel accuracy, we project high frequency sinusoidal patterns onto the scene simultaneously. But for specular surface, the high frequency patterns are susceptible to decoding errors. Incorrect decoding of high frequency patterns will result in a loss of depth resolution. Our method to resolve this problem is combining the low frequency maximum min-SW gray code and the high frequency phase shifting code, which achieves dense 3D reconstruction for specular surface. Our contributions include: (i) A complete setup of the structured light based 3D scanning system; (ii) A novel combination technique of the maximum min-SW gray code and phase shifting code. First, phase shifting decoding with sub-pixel accuracy. Then, the maximum min-SW gray code is used to resolve the ambiguity resolution. According to the experimental results and data analysis, our structured light based 3D scanning system enables high quality dense reconstruction of scenes with a small number of images. Qualitative and quantitative comparisons are performed to extract the advantages of our new

  17. Microscopic Dimensions Engineering: Stepwise Manipulation of the Surface Wettability on 3D Substrates for Oil/Water Separation.

    PubMed

    Du, Ran; Gao, Xin; Feng, Qingliang; Zhao, Qiuchen; Li, Pan; Deng, Shibin; Shi, Liurong; Zhang, Jin

    2016-02-01

    Microscopic dimensions engineering is proposed to devise a series of 3D superhydrophobic substrates with microstructures of different dimensions. Combined theoretical modeling and experiments give the relationship of surface roughness and superhydrophobic properties, important for guiding the design of superior superwettable materials for water remediation and other uses. PMID:26618329

  18. Shape analysis of hypertrophic and hypertensive heart disease using MRI-based 3D surface models of left ventricular geometry.

    PubMed

    Ardekani, Siamak; Jain, Saurabh; Sanzi, Alianna; Corona-Villalobos, Celia P; Abraham, Theodore P; Abraham, M Roselle; Zimmerman, Stefan L; Wu, Katherine C; Winslow, Raimond L; Miller, Michael I; Younes, Laurent

    2016-04-01

    The focus of this study was to develop advanced mathematical tools to construct high-resolution 3D models of left-ventricular (LV) geometry to evaluate focal geometric differences between patients with hypertrophic cardiomyopathy (HCM) and hypertensive heart disease (HHD) using cardiac magnetic resonance (MR) cross-sectional images. A limiting factor in 3D analysis of cardiac MR cross-sections is the low out-of-plane resolution of the acquired images. To overcome this problem, we have developed a mathematical framework to construct a population-based high-resolution 3D LV triangulated surface (template) in which an iterative matching algorithm maps a surface mesh of a normal heart to a set of cross-sectional contours that were extracted from short-axis cine cardiac MR images of patients who were diagnosed with either HCM or HHD. A statistical analysis was conducted on deformations that were estimated at each surface node to identify shape differences at end-diastole (ED), end-systole (ES), and motion-related shape variation from ED to ES. Some significant shape difference in radial thickness was detected at ES. Differences of LV 3D surface geometry were identified focally on the basal anterior septum wall. Further research is needed to relate these findings to the HCM morphological substrate and to design a classifier to discriminate among different etiologies of LV hypertrophy. PMID:26766206

  19. Left ventricular endocardial surface detection based on real-time 3D echocardiographic data

    NASA Technical Reports Server (NTRS)

    Corsi, C.; Borsari, M.; Consegnati, F.; Sarti, A.; Lamberti, C.; Travaglini, A.; Shiota, T.; Thomas, J. D.

    2001-01-01

    OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.

  20. A High-Transmission, Multiple Antireflective Surface Inspired from Bilayer 3D Ultrafine Hierarchical Structures in Butterfly Wing Scales.

    PubMed

    Han, Zhiwu; Mu, Zhengzhi; Li, Bo; Niu, Shichao; Zhang, Junqiu; Ren, Luquan

    2016-02-10

    A high-transmission, multiple antireflective surface inspired by bilayer 3D ultrafine hierarchical structures in butterfly wing scales is fabricated on a glass substrate using wet chemical biomimetic fabrication. Interestingly, the biomimetic antireflective surface exhibits excellent antireflective properties and high transmission, which provides better characteristics than the butterfly wings and can significantly reduce reflection without losing transparency. These findings offer a new path for generating nanostructured antireflectors with high transmission properties. PMID:26687864

  1. Reproducibly creating hierarchical 3D carbon to study the effect of Si surface functionalization on the oxygen reduction reaction.

    PubMed

    Zeng, Yuze; Flores, Jose F; Shao, Yu-Cheng; Guo, Jinghua; Chuang, Yi-De; Lu, Jennifer Q

    2016-06-01

    We report a new method to reproducibly fabricate functional 3D carbon structures directly on a current collector, e.g. stainless steel. The 3D carbon platform is formed by direct growth of upright arrays of carbon nanofiber bundles on a roughened surface of stainless steel via the seed-assisted approach. Each bundle consists of about 30 individual carbon nanofibers with a diameter of 18 nm on average. We have found that this new platform offers adequate structural integrity. As a result, no reduction of the surface area during downstream chemical functionalization was observed. With a fixed and reproducible 3D structure, the effect of the chemistry of the grafted species on the oxygen reduction reaction has been systematically investigated. This investigation reveals for the first time that non-conductive Si with an appropriate electronic structure distorts the carbon electronic structure and consequently enhances ORR electrocatalysis. The strong interface provides excellent electron connectivity according to electrochemical analysis. This highly reproducible and stable 3D platform can serve as a stepping-stone for the investigation of the effect of carbon surface functionalization on electrochemical reactions in general. PMID:27217228

  2. 2D/3D Image fusion for accurate target localization and evaluation of a mask based stereotactic system in fractionated stereotactic radiotherapy of cranial lesions

    SciTech Connect

    Jin, J.-Y.; Ryu, Samuel; Faber, Kathleen; Mikkelsen, Tom; Chen Qing; Li Shidong; Movsas, Benjamin

    2006-12-15

    The purpose of this study was to evaluate the accuracy of a two-dimensional (2D) to three-dimensional (3D) image-fusion-guided target localization system and a mask based stereotactic system for fractionated stereotactic radiotherapy (FSRT) of cranial lesions. A commercial x-ray image guidance system originally developed for extracranial radiosurgery was used for FSRT of cranial lesions. The localization accuracy was quantitatively evaluated with an anthropomorphic head phantom implanted with eight small radiopaque markers (BBs) in different locations. The accuracy and its clinical reliability were also qualitatively evaluated for a total of 127 fractions in 12 patients with both kV x-ray images and MV portal films. The image-guided system was then used as a standard to evaluate the overall uncertainty and reproducibility of the head mask based stereotactic system in these patients. The phantom study demonstrated that the maximal random error of the image-guided target localization was {+-}0.6 mm in each direction in terms of the 95% confidence interval (CI). The systematic error varied with measurement methods. It was approximately 0.4 mm, mainly in the longitudinal direction, for the kV x-ray method. There was a 0.5 mm systematic difference, primarily in the lateral direction, between the kV x-ray and the MV portal methods. The patient study suggested that the accuracy of the image-guided system in patients was comparable to that in the phantom. The overall uncertainty of the mask system was {+-}4 mm, and the reproducibility was {+-}2.9 mm in terms of 95% CI. The study demonstrated that the image guidance system provides accurate and precise target positioning.

  3. 3-D surface rendering of myocardial SPECT images segmented by level set technique.

    PubMed

    Lee, Hwun-Jae; Lee, Sangbock

    2012-06-01

    SPECT(single photon emission computed tomography) myocardial imaging is a diagnosis technique that images the region of interest and examines any change induced by disease using a computer after injects intravenously a radiopharmaceutical drug emitting gamma ray and the drug has dispersed evenly in the heart . Myocardial perfusion imaging, which contains functional information, is useful for non-invasive diagnosis of myocardial disease but noises caused by physical factors and low resolution give difficulty in reading the images. In order to help reading myocardial images, this study proposed a method that segments myocardial images and reconstructs the segmented region into a 3D image. To resolve difficulty in reading, we segmented the left ventricle, the region of interest, using a level set and modeled the segmented region into a 3D image. PMID:20839037

  4. 3D reconstruction of internal organ surfaces for minimal invasive surgery.

    PubMed

    Hu, Mingxing; Penney, Graeme; Edwards, Philip; Figl, Michael; Hawkes, David

    2007-01-01

    While Minimally Invasive Surgery (MIS) offers great benefits to patients compared with open surgery surgeons suffer from a restricted field-of-view and obstruction from instruments. We present a novel method for 3D reconstruction of soft tissue, which can provide a wider field-of-view with 3D information for surgeons, including restoration of missing data. The paper focuses on the use of Structure from Motion (SFM) techniques to solve the missing data problem and application of competitive evolutionary agents to improve the robustness to missing data and outliers. The method has been evaluated with synthetic data, images from a phantom heart model, and in vivo MIS image sequences using the da Vinci telerobotic surgical system. PMID:18051045

  5. Instrument accurately measures small temperature changes on test surface

    NASA Technical Reports Server (NTRS)

    Harvey, W. D.; Miller, H. B.

    1966-01-01

    Calorimeter apparatus accurately measures very small temperature rises on a test surface subjected to aerodynamic heating. A continuous thin sheet of a sensing material is attached to a base support plate through which a series of holes of known diameter have been drilled for attaching thermocouples to the material.

  6. 3D surface topography study of the biofunctionalized nanocrystalline Ti-6Zr-4Nb/Ca-P

    SciTech Connect

    Jakubowicz, J.; Adamek, G.; Jurczyk, M.U.; Jurczyk, M.

    2012-08-15

    In this work surface of the sintered Ti-6Zr-4Nb nanocrystalline alloy was electrochemically biofunctionalized. The porous surface was produced by anodic oxidation in 1 M H{sub 3}PO{sub 4} + 2%HF electrolyte at 10 V for 30 min. Next the calcium-phosphate (Ca-P) layer was deposited, onto the formed porous surface, using cathodic potential - 5 V kept for 60 min in 0.042 M Ca(NO{sub 3}){sub 2} + 0.025 M (NH{sub 4}){sub 2}HPO{sub 4} + 0.1 M HCl electrolyte. The deposited Ca-P layer anchored in the pores. The biofunctionalized surface was studied by XRD, SEM and EDS. In vitro tests culture of normal human osteoblast (NHOst) cells showed very good cells proliferation, colonization and multilayering. Using optical profiler, roughness and hybrid 3D surface topography parameters were estimated. Correlation between surface composition, morphology, roughness and biocompatibility results was done. It has been shown by us that surface with appropriate chemical composition and topography, after combined electrochemical anodic and cathodic surface treatment, supports osteoblast adhesion and proliferation. 3D topography measurements using optical profiler play a key role in the biomaterials surface analysis. - Highlights: Black-Right-Pointing-Pointer Nanocrystalline Ti-6Zr-4Nb/Ca-P material was produced for hard tissue implant applications. Black-Right-Pointing-Pointer Calcium-phosphate results in surface biofunctionalization. Black-Right-Pointing-Pointer The biofunctionalized surface shows good in-vitro behavior.

  7. Hierarchical bioceramic scaffolds with 3D-plotted macropores and mussel-inspired surface nanolayers for stimulating osteogenesis.

    PubMed

    Xu, Mengchi; Zhai, Dong; Xia, Lunguo; Li, Hong; Chen, Shiyi; Fang, Bing; Chang, Jiang; Wu, Chengtie

    2016-07-14

    The hierarchical structure of biomaterials plays an important role in the process of tissue reconstruction and regeneration. 3D-plotted scaffolds have been widely used for bone tissue engineering due to their controlled macropore structure and mechanical properties. However, the lack of micro- or nano-structures on the strut surface of 3D-plotted scaffolds, especially for bioceramic scaffolds, limits their biological activity. Inspired by the adhesive versatility of mussels and the active ion-chelating capacity of polydopamine, we set out to prepare a hierarchical bioceramic scaffold with controlled macropores and mussel-inspired surface nanolayers by combining the 3D-plotting technique with the polydopamine/apatite hybrid strategy in order to synergistically accelerate the osteogenesis and angiogenesis. β-Tricalcium phosphate (TCP) scaffolds were firstly 3D-plotted and then treated in dopamine-Tris/HCl and dopamine-SBF solutions to obtain TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds, respectively. It was found that polydopamine/apatite hybrid nanolayers were formed on the surface of both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds and TCP-DOPA-SBF scaffolds induced apatite mineralization for the second time during the cell culture. As compared to TCP scaffolds, both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds significantly promoted the osteogenesis of bone marrow stromal cells (BMSCs) as well as the angiogenesis of human umbilical vein endothelial cells (HUVECs), and the TCP-DOPA-SBF group presented the highest in vitro osteogenic/angiogenic activity among the three groups. Furthermore, both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds significantly improved the formation of new bone in vivo as compared to TCP scaffolds without a nanostructured surface. Our results suggest that the utilization of a mussel-inspired Ca, P-chelated polydopamine nanolayer on 3D-plotted bioceramic scaffolds is a viable and effective strategy to construct a hierarchical structure for synergistically

  8. A global model simulation for 3-D radiative transfer impact on surface hydrology over the Sierra Nevada and Rocky Mountains

    DOE PAGESBeta

    Lee, W.-L.; Gu, Y.; Liou, K. N.; Leung, L. R.; Hsu, H.-H.

    2015-05-19

    We investigate 3-D mountain effects on solar flux distributions and their impact on surface hydrology over the western United States, specifically the Rocky Mountains and the Sierra Nevada, using the global CCSM4 (Community Climate System Model version 4; Community Atmosphere Model/Community Land Model – CAM4/CLM4) with a 0.23° × 0.31° resolution for simulations over 6 years. In a 3-D radiative transfer parameterization, we have updated surface topography data from a resolution of 1 km to 90 m to improve parameterization accuracy. In addition, we have also modified the upward-flux deviation (3-D–PP (plane-parallel)) adjustment to ensure that the energy balance atmore » the surface is conserved in global climate simulations based on 3-D radiation parameterization. We show that deviations in the net surface fluxes are not only affected by 3-D mountains but also influenced by feedbacks of cloud and snow in association with the long-term simulations. Deviations in sensible heat and surface temperature generally follow the patterns of net surface solar flux. The monthly snow water equivalent (SWE) deviations show an increase in lower elevations due to reduced snowmelt, leading to a reduction in cumulative runoff. Over higher-elevation areas, negative SWE deviations are found because of increased solar radiation available at the surface. Simulated precipitation increases for lower elevations, while it decreases for higher elevations, with a minimum in April. Liquid runoff significantly decreases at higher elevations after April due to reduced SWE and precipitation.« less

  9. Forensic 3D Scene Reconstruction

    SciTech Connect

    LITTLE,CHARLES Q.; PETERS,RALPH R.; RIGDON,J. BRIAN; SMALL,DANIEL E.

    1999-10-12

    Traditionally law enforcement agencies have relied on basic measurement and imaging tools, such as tape measures and cameras, in recording a crime scene. A disadvantage of these methods is that they are slow and cumbersome. The development of a portable system that can rapidly record a crime scene with current camera imaging, 3D geometric surface maps, and contribute quantitative measurements such as accurate relative positioning of crime scene objects, would be an asset to law enforcement agents in collecting and recording significant forensic data. The purpose of this project is to develop a feasible prototype of a fast, accurate, 3D measurement and imaging system that would support law enforcement agents to quickly document and accurately record a crime scene.

  10. Forensic 3D scene reconstruction

    NASA Astrophysics Data System (ADS)

    Little, Charles Q.; Small, Daniel E.; Peters, Ralph R.; Rigdon, J. B.

    2000-05-01

    Traditionally law enforcement agencies have relied on basic measurement and imaging tools, such as tape measures and cameras, in recording a crime scene. A disadvantage of these methods is that they are slow and cumbersome. The development of a portable system that can rapidly record a crime scene with current camera imaging, 3D geometric surface maps, and contribute quantitative measurements such as accurate relative positioning of crime scene objects, would be an asset to law enforcement agents in collecting and recording significant forensic data. The purpose of this project is to develop a fieldable prototype of a fast, accurate, 3D measurement and imaging system that would support law enforcement agents to quickly document and accurately record a crime scene.

  11. 3d-transition metal induced enhancement of molecular hydrogen adsorption on Mg(0001) surface: An Ab-initio study

    NASA Astrophysics Data System (ADS)

    Banerjee, Paramita; Das, G. P.

    2016-05-01

    In our effort to do first principles design of suitable materials for hydrogen storage, we have explored the interaction characteristics of a hydrogen molecule with pure as well as a 3d-transition metal (TM) atom doped Mg(0001) surface using density functional theory (DFT) based approach. Doping of a 3d-TM atom by creating a vacancy on the top most layer of Mg(0001) surface, enhances the molecular hydrogen adsorption efficiency of this surface by ~ 6 times. The TM atom gains some charge from the defected site of the Mg(0001) surface, becomes anionic and adsorbs the hydrogen molecule via Anti Kubas-type interaction. The interaction energy of this H2 molecule, including van der Waals dispersion correction, turns out to be ~ 0.4 eV, which falls in the right energy window between physisorption and chemisorption. On full coverage of this 3d-TM atom doped Mg(0001) surface with hydrogen molecules, the gravimetric density of hydrogen has been estimated to be ~ 5.6 wt %, thereby satisfying the criteria set by the department of energy (DOE) for efficient hydrogen storage.

  12. Examination about Influence for Precision of 3d Image Measurement from the Ground Control Point Measurement and Surface Matching

    NASA Astrophysics Data System (ADS)

    Anai, T.; Kochi, N.; Yamada, M.; Sasaki, T.; Otani, H.; Sasaki, D.; Nishimura, S.; Kimoto, K.; Yasui, N.

    2015-05-01

    As the 3D image measurement software is now widely used with the recent development of computer-vision technology, the 3D measurement from the image is now has acquired the application field from desktop objects as wide as the topography survey in large geographical areas. Especially, the orientation, which used to be a complicated process in the heretofore image measurement, can be now performed automatically by simply taking many pictures around the object. And in the case of fully textured object, the 3D measurement of surface features is now done all automatically from the orientated images, and greatly facilitated the acquisition of the dense 3D point cloud from images with high precision. With all this development in the background, in the case of small and the middle size objects, we are now furnishing the all-around 3D measurement by a single digital camera sold on the market. And we have also developed the technology of the topographical measurement with the air-borne images taken by a small UAV [1~5]. In this present study, in the case of the small size objects, we examine the accuracy of surface measurement (Matching) by the data of the experiments. And as to the topographic measurement, we examine the influence of GCP distribution on the accuracy by the data of the experiments. Besides, we examined the difference of the analytical results in each of the 3D image measurement software. This document reviews the processing flow of orientation and the 3D measurement of each software and explains the feature of the each software. And as to the verification of the precision of stereo-matching, we measured the test plane and the test sphere of the known form and assessed the result. As to the topography measurement, we used the air-borne image data photographed at the test field in Yadorigi of Matsuda City, Kanagawa Prefecture JAPAN. We have constructed Ground Control Point which measured by RTK-GPS and Total Station. And we show the results of analysis made

  13. Verification of Long Period Surface Waves from Ambient Noise and Its Application in Constructing 3D Shear Wave Structure of Lithosphere in United States

    NASA Astrophysics Data System (ADS)

    Xie, J.; Yang, Y.; Ni, S.; Zhao, K.

    2015-12-01

    In the past decade, ambient noise tomography (ANT) has become an estimated method to construct the earth's interior structures thanks to its advantage in extracting surface waves from cross-correlations of ambient noise without using earthquake data. However, most of previous ambient noise tomography studies concentrate on short and intermediate periods (<50sec) due to the dominant energy of the microseism at these periods. Studies of long period surface waves from cross-correlation of ambient noise are limited. In this study, we verify the accuracy of the long period (50-250sec) surface wave (Rayleigh wave) from ambient noise by comparing both dispersion curves and seismic waveforms from ambient noise with those from earthquake records quantitatively. After that, we calculate vertical-vertical cross-correlation functions among more than1800 USArray Transportable Array stations and extract high quality interstation phase velocity dispersion curves from them at 10-200 sec periods. Then, we adopt a finite frequency ambient noise tomography method based on Born approximation to obtain high resolution phase velocity maps using the obtained dispersion measurements at 10-150 sec periods. Afterward, we extract local dispersion curves from these dispersion maps and invert them for 1D shear wave velocity profiles at individual grids using a Bayesian Monte Carlo method. Finally, a 3D shear velocity model is constructed by assembling all the 1D Vs profiles. Our 3D model is overall similar to other models constructed using earthquake surface waves and body waves. In summary, we demonstrate that the long period surface waves can be extracted from ambient noise, and the long period dispersion measurements from ambient noise are as accurate as those from earthquake data and can be used to construct 3D lithospheric structure from surface down to lithosphere/asthenosphere depths.

  14. Combining 3D human in vitro methods for a 3Rs evaluation of novel titanium surfaces in orthopaedic applications

    PubMed Central

    Stevenson, G.; Rehman, S.; Draper, E.; Hernández‐Nava, E.; Hunt, J.

    2016-01-01

    ABSTRACT In this study, we report on a group of complementary human osteoblast in vitro test methods for the preclinical evaluation of 3D porous titanium surfaces. The surfaces were prepared by additive manufacturing (electron beam melting [EBM]) and plasma spraying, allowing the creation of complex lattice surface geometries. Physical properties of the surfaces were characterized by SEM and profilometry and 3D in vitro cell culture using human osteoblasts. Primary human osteoblast cells were found to elicit greater differences between titanium sample surfaces than an MG63 osteoblast‐like cell line, particularly in terms of cell survival. Surface morphology was associated with higher osteoblast metabolic activity and mineralization on rougher titanium plasma spray coated surfaces than smoother surfaces. Differences in osteoblast survival and metabolic activity on titanium lattice structures were also found, despite analogous surface morphology at the cellular level. 3D confocal microscopy identified osteoblast organization within complex titanium surface geometries, adhesion, spreading, and alignment to the biomaterial strut geometries. Mineralized nodule formation throughout the lattice structures was also observed, and indicative of early markers of bone in‐growth on such materials. Testing methods such as those presented are not traditionally considered by medical device manufacturers, but we suggest have value as an increasingly vital tool in efficiently translating pre‐clinical studies, especially in balance with current regulatory practice, commercial demands, the 3Rs, and the relative merits of in vitro and in vivo studies. Biotechnol. Bioeng. 2016;113: 1586–1599. © 2015 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc. PMID:26702609

  15. Combining 3D human in vitro methods for a 3Rs evaluation of novel titanium surfaces in orthopaedic applications.

    PubMed

    Stevenson, G; Rehman, S; Draper, E; Hernández-Nava, E; Hunt, J; Haycock, J W

    2016-07-01

    In this study, we report on a group of complementary human osteoblast in vitro test methods for the preclinical evaluation of 3D porous titanium surfaces. The surfaces were prepared by additive manufacturing (electron beam melting [EBM]) and plasma spraying, allowing the creation of complex lattice surface geometries. Physical properties of the surfaces were characterized by SEM and profilometry and 3D in vitro cell culture using human osteoblasts. Primary human osteoblast cells were found to elicit greater differences between titanium sample surfaces than an MG63 osteoblast-like cell line, particularly in terms of cell survival. Surface morphology was associated with higher osteoblast metabolic activity and mineralization on rougher titanium plasma spray coated surfaces than smoother surfaces. Differences in osteoblast survival and metabolic activity on titanium lattice structures were also found, despite analogous surface morphology at the cellular level. 3D confocal microscopy identified osteoblast organization within complex titanium surface geometries, adhesion, spreading, and alignment to the biomaterial strut geometries. Mineralized nodule formation throughout the lattice structures was also observed, and indicative of early markers of bone in-growth on such materials. Testing methods such as those presented are not traditionally considered by medical device manufacturers, but we suggest have value as an increasingly vital tool in efficiently translating pre-clinical studies, especially in balance with current regulatory practice, commercial demands, the 3Rs, and the relative merits of in vitro and in vivo studies. Biotechnol. Bioeng. 2016;113: 1586-1599. © 2015 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc. PMID:26702609

  16. Modeling of 3d Space-time Surface of Potential Fields and Hydrogeologic Modeling of Nuclear Waste Disposal Sites

    NASA Astrophysics Data System (ADS)

    Shestopalov, V.; Bondarenko, Y.; Zayonts, I.; Rudenko, Y.

    Introduction After the Chernobyl Nuclear Power Plant (CNPP) disaster (04.26.1986) a huge amount (over 2000 sq. km) of nuclear wastes appeared within so-called "Cher- nobyl Exclusion Zone" (CEZ). At present there are not enough storage facilities in the Ukraine for safe disposal of nuclear wastes and hazardous chemical wastes. The urgent problem now is safe isolation of these dangerous wastes. According to the developed state program of radioactive waste management, the construction of a na- tional storage facility of nuclear wastes is planned. It is also possible to create regional storage facilities for hazardous chemical wastes. The region of our exploration cov- ers the eastern part of the Korosten Plutone and its slope, reaching the CNPP. 3D Space-Time Surface Imaging of Geophysical Fields. There are only three direct meth- ods of stress field reconstruction in present practice, namely the field investigations based on the large-scale fracturing tests, petrotectonic and optical polarization meth- ods. Unfortunately, all these methods are extremely laborious and need the regular field tests, which is difficult to conduct in the areas of anisotropic rock outcrops. A compilation of magnetic and gravity data covering the CNPP area was carried out as a prelude to an interpretation study. More than thirty map products were generated from magnetic, gravity and geodesy data to prepare the 3D Space-Time Surface Images (3D STSI). Multi-layer topography and geophysic surfaces included: total magnetic intensity, isostatically-corrected Bouguer gravity, aspect and slope, first and second derivatives, vertical and horizontal curvature, histogram characteristics and space cor- relation coefficients between the gradient fields. Many maps shows the first and sec- ond derivatives of the potential fields, with the results of lineament (edge) structure detection superimposed. The lineament or edges of the potential fields are located from maximal gradient in many directions

  17. 3D-printed surface mould applicator for high-dose-rate brachytherapy

    NASA Astrophysics Data System (ADS)

    Schumacher, Mark; Lasso, Andras; Cumming, Ian; Rankin, Adam; Falkson, Conrad B.; Schreiner, L. John; Joshi, Chandra; Fichtinger, Gabor

    2015-03-01

    In contemporary high-dose-rate brachytherapy treatment of superficial tumors, catheters are placed in a wax mould. The creation of current wax models is a difficult and time consuming proces.The irradiation plan can only be computed post-construction and requires a second CT scan. In case no satisfactory dose plan can be created, the mould is discarded and the process is repeated. The objective of this work was to develop an automated method to replace suboptimal wax moulding. We developed a method to design and manufacture moulds that guarantee to yield satisfactory dosimetry. A 3D-printed mould with channels for the catheters designed from the patient's CT and mounted on a patient-specific thermoplastic mesh mask. The mould planner was implemented as an open-source module in the 3D Slicer platform. Series of test moulds were created to accommodate standard brachytherapy catheters of 1.70mm diameter. A calibration object was used to conclude that tunnels with a diameter of 2.25mm, minimum 12mm radius of curvature, and 1.0mm open channel gave the best fit for this printer/catheter combination. Moulds were created from the CT scan of thermoplastic mesh masks of actual patients. The patient-specific moulds have been visually verified to fit on the thermoplastic meshes. The masks were visually shown to fit onto the thermoplastic meshes, next the resulting dosimetry will have to be compared with treatment plans and dosimetry achieved with conventional wax moulds in order to validate our 3D printed moulds.

  18. Dielectrophoresis with 3D microelectrodes fabricated by surface tension assisted lithography.

    PubMed

    Nasabi, Mahyar; Khoshmanesh, Khashayar; Tovar-Lopez, Francisco J; Kalantar-Zadeh, Kourosh; Mitchell, Arnan

    2013-12-01

    This paper demonstrates the utilization of 3D semispherical shaped microelectrodes for dielectrophoretic manipulation of yeast cells. The semispherical microelectrodes are capable of producing strong electric field gradients, and in turn dielectrophoretic forces across a large area of channel cross-section. The semispherical shape of microelectrodes avoids the formation of undesired sharp electric fields along the structure and also minimizes the disturbance of the streamlines of nearby passing fluid. The advantage of semispherical microelectrodes over the planar microelectrodes is demonstrated in a series of numerical simulations and proof-of-concept experiments aimed toward immobilization of viable yeast cells. PMID:24347270

  19. Vessels as 4-D curves: global minimal 4-D paths to extract 3-D tubular surfaces and centerlines.

    PubMed

    Li, Hua; Yezzi, Anthony

    2007-09-01

    In this paper, we propose an innovative approach to the segmentation of tubular structures. This approach combines all of the benefits of minimal path techniques such as global minimizers, fast computation, and powerful incorporation of user input, while also having the capability to represent and detect vessel surfaces directly which so far has been a feature restricted to active contour and surface techniques. The key is to represent the trajectory of a tubular structure not as a 3-D curve but to go up a dimension and represent the entire structure as a 4-D curve. Then we are able to fully exploit minimal path techniques to obtain global minimizing trajectories between two user supplied endpoints in order to reconstruct tubular structures from noisy or low contrast 3-D data without the sensitivity to local minima inherent in most active surface techniques. In contrast to standard purely spatial 3-D minimal path techniques, however, we are able to represent a full tubular surface rather than just a curve which runs through its interior. Our representation also yields a natural notion of a tube's "central curve." We demonstrate and validate the utility of this approach on magnetic resonance (MR) angiography and computed tomography (CT) images of coronary arteries. PMID:17896594

  20. Simulation of the 3D viscoelastic free surface flow by a parallel corrected particle scheme

    NASA Astrophysics Data System (ADS)

    Jin-Lian, Ren; Tao, Jiang

    2016-02-01

    In this work, the behavior of the three-dimensional (3D) jet coiling based on the viscoelastic Oldroyd-B model is investigated by a corrected particle scheme, which is named the smoothed particle hydrodynamics with corrected symmetric kernel gradient and shifting particle technique (SPH_CS_SP) method. The accuracy and stability of SPH_CS_SP method is first tested by solving Poiseuille flow and Taylor-Green flow. Then the capacity for the SPH_CS_SP method to solve the viscoelastic fluid is verified by the polymer flow through a periodic array of cylinders. Moreover, the convergence of the SPH_CS_SP method is also investigated. Finally, the proposed method is further applied to the 3D viscoelastic jet coiling problem, and the influences of macroscopic parameters on the jet coiling are discussed. The numerical results show that the SPH_CS_SP method has higher accuracy and better stability than the traditional SPH method and other corrected SPH method, and can improve the tensile instability. Project supported by the Natural Science Foundation of Jiangsu Province, China (Grant Nos. BK20130436 and BK20150436) and the Natural Science Foundation of the Higher Education Institutions of Jiangsu Province, China (Grant No. 15KJB110025).

  1. Macroscopic Degeneracy of Zero-Mode Rotating Surface States in 3D Dirac and Weyl Semimetals under Radiation.

    PubMed

    González, José; Molina, Rafael A

    2016-04-15

    We investigate the development of novel surface states when 3D Dirac or Weyl semimetals are placed under circularly polarized electromagnetic radiation. We find that the hybridization between inverted Floquet bands opens, in general, a gap, which closes at so-called exceptional points found for complex values of the momentum. This corresponds to the appearance of midgap surface states in the form of evanescent waves decaying from the surface exposed to the radiation. We observe a phenomenon reminiscent of Landau quantization by which the midgap surface states get a large degeneracy proportional to the radiation flux traversing the surface of the semimetal. We show that all of these surface states carry angular current, leading to an angular modulation of their charge that rotates with the same frequency of the radiation, which should manifest in the observation of a macroscopic chiral current in the irradiated surface. PMID:27127980

  2. Macroscopic Degeneracy of Zero-Mode Rotating Surface States in 3D Dirac and Weyl Semimetals under Radiation

    NASA Astrophysics Data System (ADS)

    González, José; Molina, Rafael A.

    2016-04-01

    We investigate the development of novel surface states when 3D Dirac or Weyl semimetals are placed under circularly polarized electromagnetic radiation. We find that the hybridization between inverted Floquet bands opens, in general, a gap, which closes at so-called exceptional points found for complex values of the momentum. This corresponds to the appearance of midgap surface states in the form of evanescent waves decaying from the surface exposed to the radiation. We observe a phenomenon reminiscent of Landau quantization by which the midgap surface states get a large degeneracy proportional to the radiation flux traversing the surface of the semimetal. We show that all of these surface states carry angular current, leading to an angular modulation of their charge that rotates with the same frequency of the radiation, which should manifest in the observation of a macroscopic chiral current in the irradiated surface.

  3. Fast and Accurate Data Extraction for Near Real-Time Registration of 3-D Ultrasound and Computed Tomography in Orthopedic Surgery.

    PubMed

    Brounstein, Anna; Hacihaliloglu, Ilker; Guy, Pierre; Hodgson, Antony; Abugharbieh, Rafeef

    2015-12-01

    Automatic, accurate and real-time registration is an important step in providing effective guidance and successful anatomic restoration in ultrasound (US)-based computer assisted orthopedic surgery. We propose a method in which local phase-based bone surfaces, extracted from intra-operative US data, are registered to pre-operatively segmented computed tomography data. Extracted bone surfaces are downsampled and reinforced with high curvature features. A novel hierarchical simplification algorithm is used to further optimize the point clouds. The final point clouds are represented as Gaussian mixture models and iteratively matched by minimizing the dissimilarity between them using an L2 metric. For 44 clinical data sets from 25 pelvic fracture patients and 49 phantom data sets, we report mean surface registration accuracies of 0.31 and 0.77 mm, respectively, with an average registration time of 1.41 s. Our results suggest the viability and potential of the chosen method for real-time intra-operative registration in orthopedic surgery. PMID:26365924

  4. 3D palmprint data fast acquisition and recognition

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoxu; Huang, Shujun; Gao, Nan; Zhang, Zonghua

    2014-11-01

    This paper presents a fast 3D (Three-Dimension) palmprint capturing system and develops an efficient 3D palmprint feature extraction and recognition method. In order to fast acquire accurate 3D shape and texture of palmprint, a DLP projector triggers a CCD camera to realize synchronization. By generating and projecting green fringe pattern images onto the measured palm surface, 3D palmprint data are calculated from the fringe pattern images. The periodic feature vector can be derived from the calculated 3D palmprint data, so undistorted 3D biometrics is obtained. Using the obtained 3D palmprint data, feature matching test have been carried out by Gabor filter, competition rules and the mean curvature. Experimental results on capturing 3D palmprint show that the proposed acquisition method can fast get 3D shape information of palmprint. Some initial experiments on recognition show the proposed method is efficient by using 3D palmprint data.

  5. Application of 3D Scanned Imaging Methodology for Volume, Surface Area, and Envelope Density Evaluation of Densified Biomass

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Measurement of surface area, volume, and density is an essential for quantifying, evaluating, and designing the biomass densification, storage, and transport operations. Acquiring accurate and repeated measurements of these parameters for hygroscopic densified biomass are not straightforward and on...

  6. Surface Acoustic Waves (SAW)-Based Biosensing for Quantification of Cell Growth in 2D and 3D Cultures

    PubMed Central

    Wang, Tao; Green, Ryan; Nair, Rajesh Ramakrishnan; Howell, Mark; Mohapatra, Subhra; Guldiken, Rasim; Mohapatra, Shyam Sundar

    2015-01-01

    Detection and quantification of cell viability and growth in two-dimensional (2D) and three-dimensional (3D) cell cultures commonly involve harvesting of cells and therefore requires a parallel set-up of several replicates for time-lapse or dose–response studies. Thus, developing a non-invasive and touch-free detection of cell growth in longitudinal studies of 3D tumor spheroid cultures or of stem cell regeneration remains a major unmet need. Since surface acoustic waves (SAWs) permit mass loading-based biosensing and have been touted due to their many advantages including low cost, small size and ease of assembly, we examined the potential of SAW-biosensing to detect and quantify cell growth. Herein, we demonstrate that a shear horizontal-surface acoustic waves (SH-SAW) device comprising two pairs of resonators consisting of interdigital transducers and reflecting fingers can be used to quantify mass loading by the cells in suspension as well as within a 3D cell culture platform. A 3D COMSOL model was built to simulate the mass loading response of increasing concentrations of cells in suspension in the polydimethylsiloxane (PDMS) well in order to predict the characteristics and optimize the design of the SH-SAW biosensor. The simulated relative frequency shift from the two oscillatory circuit systems (one of which functions as control) were found to be concordant to experimental data generated with RAW264.7 macrophage and A549 cancer cells. In addition, results showed that SAW measurements per se did not affect viability of cells. Further, SH-SAW biosensing was applied to A549 cells cultured on a 3D electrospun nanofiber scaffold that generate tumor spheroids (tumoroids) and the results showed the device's ability to detect changes in tumor spheroid growth over the course of eight days. Taken together, these results demonstrate the use of SH-SAW device for detection and quantification of cell growth changes over time in 2D suspension cultures and in 3D cell

  7. Surface Acoustic Waves (SAW)-Based Biosensing for Quantification of Cell Growth in 2D and 3D Cultures.

    PubMed

    Wang, Tao; Green, Ryan; Nair, Rajesh Ramakrishnan; Howell, Mark; Mohapatra, Subhra; Guldiken, Rasim; Mohapatra, Shyam Sundar

    2015-01-01

    Detection and quantification of cell viability and growth in two-dimensional (2D) and three-dimensional (3D) cell cultures commonly involve harvesting of cells and therefore requires a parallel set-up of several replicates for time-lapse or dose-response studies. Thus, developing a non-invasive and touch-free detection of cell growth in longitudinal studies of 3D tumor spheroid cultures or of stem cell regeneration remains a major unmet need. Since surface acoustic waves (SAWs) permit mass loading-based biosensing and have been touted due to their many advantages including low cost, small size and ease of assembly, we examined the potential of SAW-biosensing to detect and quantify cell growth. Herein, we demonstrate that a shear horizontal-surface acoustic waves (SH-SAW) device comprising two pairs of resonators consisting of interdigital transducers and reflecting fingers can be used to quantify mass loading by the cells in suspension as well as within a 3D cell culture platform. A 3D COMSOL model was built to simulate the mass loading response of increasing concentrations of cells in suspension in the polydimethylsiloxane (PDMS) well in order to predict the characteristics and optimize the design of the SH-SAW biosensor. The simulated relative frequency shift from the two oscillatory circuit systems (one of which functions as control) were found to be concordant to experimental data generated with RAW264.7 macrophage and A549 cancer cells. In addition, results showed that SAW measurements per se did not affect viability of cells. Further, SH-SAW biosensing was applied to A549 cells cultured on a 3D electrospun nanofiber scaffold that generate tumor spheroids (tumoroids) and the results showed the device's ability to detect changes in tumor spheroid growth over the course of eight days. Taken together, these results demonstrate the use of SH-SAW device for detection and quantification of cell growth changes over time in 2D suspension cultures and in 3D cell

  8. Observer success rates for identification of 3D surface reconstructed facial images and implications for patient privacy and security

    NASA Astrophysics Data System (ADS)

    Chen, Joseph J.; Siddiqui, Khan M.; Fort, Leslie; Moffitt, Ryan; Juluru, Krishna; Kim, Woojin; Safdar, Nabile; Siegel, Eliot L.

    2007-03-01

    3D and multi-planar reconstruction of CT images have become indispensable in the routine practice of diagnostic imaging. These tools cannot only enhance our ability to diagnose diseases, but can also assist in therapeutic planning as well. The technology utilized to create these can also render surface reconstructions, which may have the undesired potential of providing sufficient detail to allow recognition of facial features and consequently patient identity, leading to violation of patient privacy rights as described in the HIPAA (Health Insurance Portability and Accountability Act) legislation. The purpose of this study is to evaluate whether 3D reconstructed images of a patient's facial features can indeed be used to reliably or confidently identify that specific patient. Surface reconstructed images of the study participants were created used as candidates for matching with digital photographs of participants. Data analysis was performed to determine the ability of observers to successfully match 3D surface reconstructed images of the face with facial photographs. The amount of time required to perform the match was recorded as well. We also plan to investigate the ability of digital masks or physical drapes to conceal patient identity. The recently expressed concerns over the inability to truly "anonymize" CT (and MRI) studies of the head/face/brain are yet to be tested in a prospective study. We believe that it is important to establish whether these reconstructed images are a "threat" to patient privacy/security and if so, whether minimal interventions from a clinical perspective can substantially reduce this possibility.

  9. Matching Images to Models: Camera Calibration for 3-D Surface Reconstruction

    NASA Technical Reports Server (NTRS)

    Morris, Robin D.; Smelyanskiy, Vadim N.; Cheeseman. Peter C.; Norvig, Peter (Technical Monitor)

    2001-01-01

    In a previous paper we described a system which recursively recovers a super-resolved three dimensional surface model from a set of images of the surface. In that paper we assumed that the camera calibration for each image was known. In this paper we solve two problems. Firstly, if an estimate of the surface is already known, the problem is to calibrate a new image relative to the existing surface model. Secondly, if no surface estimate is available, the relative camera calibration between the images in the set must be estimated. This will allow an initial surface model to be estimated. Results of both types of estimation are given.

  10. Accurate Prediction of Binding Thermodynamics for DNA on Surfaces

    PubMed Central

    Vainrub, Arnold; Pettitt, B. Montgomery

    2011-01-01

    For DNA mounted on surfaces for microarrays, microbeads and nanoparticles, the nature of the random attachment of oligonucleotide probes to an amorphous surface gives rise to a locally inhomogeneous probe density. These fluctuations of the probe surface density are inherent to all common surface or bead platforms, regardless if they exploit either an attachment of pre-synthesized probes or probes synthesized in situ on the surface. Here, we demonstrate for the first time the crucial role of the probe surface density fluctuations in performance of DNA arrays. We account for the density fluctuations with a disordered two-dimensional surface model and derive the corresponding array hybridization isotherm that includes a counter-ion screened electrostatic repulsion between the assayed DNA and probe array. The calculated melting curves are in excellent agreement with published experimental results for arrays with both pre-synthesized and in-situ synthesized oligonucleotide probes. The approach developed allows one to accurately predict the melting curves of DNA arrays using only the known sequence dependent hybridization enthalpy and entropy in solution and the experimental macroscopic surface density of probes. This opens the way to high precision theoretical design and optimization of probes and primers in widely used DNA array-based high-throughput technologies for gene expression, genotyping, next-generation sequencing, and surface polymerase extension. PMID:21972932

  11. Wavelet transform analysis of truncated fringe patterns in 3-D surface profilometry

    NASA Astrophysics Data System (ADS)

    Gorthi, Sai Siva; Lolla, Kameswara R.

    2005-06-01

    Wavelet transform analysis of projected fringe pattern for phase recovery in 3-D shape measurement of objects is investigated. The present communication specifically outlines and evaluates the errors that creep in to the reconstructed profiles when fringe images do not satisfy periodicity. Three specific cases that give raise to non-periodicity of fringe image are simulated and leakage effects caused by each one of them are analyzed with continuous complex Morlet wavelet transform. Same images are analyzed with FFT method to make a comparison of the reconstructed profiles with both methods. Simulation results revealed a significant advantage of wavelet transform profilometry (WTP), that the distortions that arise due to leakage are confined to the locations of discontinuity and do not spread out over the entire projection as in the case of Fourier transform profilometry (FTP).

  12. 3D MHD Simulations of accreting neutron stars: evidence of QPO emission from the surface

    SciTech Connect

    Bachetti, Matteo; Burderi, Luciano; Romanova, Marina M.; Kulkarni, Akshay; Salvo, Tiziana di

    2010-07-15

    3D Magnetohydrodynamic simulations show that when matter accretes onto neutron stars, in particular if the misalignment angle is small, it does not constantly fall at a fixed spot. Instead, the location at which matter reaches the star moves. These moving hot spots can be produced both during stable accretion, where matter falls near the magnetic poles of the star, and unstable accretion, characterized by the presence of several tongues of matter which fall on the star near the equator, due to Rayleigh-Taylor instabilities. Precise modeling with Monte Carlo simulations shows that those movements could be observed as high frequency Quasi Periodic Oscillations. We performed a number of new simulation runs with a much wider set of parameters, focusing on neutron stars with a small misalignment angle. In most cases we observe oscillations whose frequency is correlated with the mass accretion rate M. Moreover, in some cases double QPOs appear, each of them showing the same correlation with M.

  13. Effects of Surface Morphology on the 3D Topological Insulator Samarium Hexaboride

    NASA Astrophysics Data System (ADS)

    Wolgast, Steven; Eo, Yun Suk; Kurdak, Cagliyan; Kim, Dae-Jeong; Fisk, Zachary

    2015-03-01

    The recent verification of a topologically-protected surface state in SmB6 at low temperatures has led to several transport studies of the surface states. This task is complicated because current can flow on all surfaces of a topological insulator, each of which can have different transport characteristics. Our own measurements using a Corbino disc geometry overcome this difficulty, limiting the conduction to individual surfaces. However, the sheet conductivities of our samples counter-intuitively decrease with finer surface polishing. We therefore investigate surface and sub-surface morphology as a factor affecting the surface conductivity. Specifically, surface cracks may themselves harbor surface states and contribute to the total electrical conduction, yielding a higher measured sheet conductivity than that of a flat surface. This situation may contribute to the (sometimes unphysically) large surface conductivities already observed in SmB6. Performed in part at the Lurie Nanofabrication Facility and the Electron Microbeam Analysis Laboratory. Funded by NSF Grant #DMR-1006500 and DMR-1441965. Thanks to Gang Li and Fan Yu for optical imaging.

  14. A 3D immersed finite element method with non-homogeneous interface flux jump for applications in particle-in-cell simulations of plasma-lunar surface interactions

    NASA Astrophysics Data System (ADS)

    Han, Daoru; Wang, Pu; He, Xiaoming; Lin, Tao; Wang, Joseph

    2016-09-01

    Motivated by the need to handle complex boundary conditions efficiently and accurately in particle-in-cell (PIC) simulations, this paper presents a three-dimensional (3D) linear immersed finite element (IFE) method with non-homogeneous flux jump conditions for solving electrostatic field involving complex boundary conditions using structured meshes independent of the interface. This method treats an object boundary as part of the simulation domain and solves the electric field at the boundary as an interface problem. In order to resolve charging on a dielectric surface, a new 3D linear IFE basis function is designed for each interface element to capture the electric field jump on the interface. Numerical experiments are provided to demonstrate the optimal convergence rates in L2 and H1 norms of the IFE solution. This new IFE method is integrated into a PIC method for simulations involving charging of a complex dielectric surface in a plasma. A numerical study of plasma-surface interactions at the lunar terminator is presented to demonstrate the applicability of the new method.

  15. 3D non-rigid registration using surface and local salient features for transrectal ultrasound image-guided prostate biopsy

    NASA Astrophysics Data System (ADS)

    Yang, Xiaofeng; Akbari, Hamed; Halig, Luma; Fei, Baowei

    2011-03-01

    We present a 3D non-rigid registration algorithm for the potential use in combining PET/CT and transrectal ultrasound (TRUS) images for targeted prostate biopsy. Our registration is a hybrid approach that simultaneously optimizes the similarities from point-based registration and volume matching methods. The 3D registration is obtained by minimizing the distances of corresponding points at the surface and within the prostate and by maximizing the overlap ratio of the bladder neck on both images. The hybrid approach not only capture deformation at the prostate surface and internal landmarks but also the deformation at the bladder neck regions. The registration uses a soft assignment and deterministic annealing process. The correspondences are iteratively established in a fuzzy-to-deterministic approach. B-splines are used to generate a smooth non-rigid spatial transformation. In this study, we tested our registration with pre- and postbiopsy TRUS images of the same patients. Registration accuracy is evaluated using manual defined anatomic landmarks, i.e. calcification. The root-mean-squared (RMS) of the difference image between the reference and floating images was decreased by 62.6+/-9.1% after registration. The mean target registration error (TRE) was 0.88+/-0.16 mm, i.e. less than 3 voxels with a voxel size of 0.38×0.38×0.38 mm3 for all five patients. The experimental results demonstrate the robustness and accuracy of the 3D non-rigid registration algorithm.

  16. Myosin-II controls cellular branching morphogenesis and migration in 3D by minimizing cell surface curvature

    PubMed Central

    Elliott, Hunter; Fischer, Robert A.; Myers, Kenneth A.; Desai, Ravi A.; Gao, Lin; Chen, Christopher S.; Adelstein, Robert; Waterman, Clare M.; Danuser, Gaudenz

    2014-01-01

    In many cases cell function is intimately linked to cell shape control. We utilized endothelial cell branching morphogenesis as a model to understand the role of myosin-II in shape control of invasive cells migrating in 3D collagen gels. We applied principles of differential geometry and mathematical morphology to 3D image sets to parameterize cell branch structure and local cell surface curvature. We find that Rho/ROCK-stimulated myosin-II contractility minimizes cell-scale branching by recognizing and minimizing local cell surface curvature. Utilizing micro-fabrication to constrain cell shape identifies a positive feedback mechanism in which low curvature stabilizes myosin-II cortical association, where it acts to maintain minimal curvature. The feedback between myosin-II regulation by and control of curvature drives cycles of localized cortical myosin-II assembly and disassembly. These cycles in turn mediate alternating phases of directionally biased branch initiation and retraction to guide 3D cell migration. PMID:25621949

  17. Tunable 3D and 2D polystyrene nanoparticle assemblies using surface wettability, low volume fraction and surfactant effects

    NASA Astrophysics Data System (ADS)

    Pillai, S.; Hemmersam, A. G.; Mukhopadhyay, R.; Meyer, R. L.; Moghimi, S. M.; Besenbacher, F.; Kingshott, P.

    2009-01-01

    Polymer-based nanopatterning on metal surfaces is of increasing importance to a number of applications, including biosensors, bioelectronic devices and medical implants. Here we show that polycrystalline gold surfaces can be functionalized with monocomponent nanoparticle (NP) assemblies by a simple drop deposition method. Ordered 3D hexagonal close-packed structures consisting of 350 nm polystyrene (PS) NPs on hydrophobically modified gold surfaces from solutions of very low volume fraction (phiv = 0.0006) were obtained as a result of capillary force induced self-assembly, whilst 2D self-assembly of PS NPs was generated over large area on hydrophilic gold and TiO2 surfaces by spin coating. Furthermore, we show that when Triton X-100 is added to the PS NP suspending medium longer range ordering is obtained. Our observations may initiate interesting applications in the areas of nanoengineering of metal-based sensors and as a means to design new nanostructures for biocompatible implant surfaces.

  18. Joint detection of anatomical points on surface meshes and color images for visual registration of 3D dental models

    NASA Astrophysics Data System (ADS)

    Destrez, Raphaël.; Albouy-Kissi, Benjamin; Treuillet, Sylvie; Lucas, Yves

    2015-04-01

    Computer aided planning for orthodontic treatment requires knowing occlusion of separately scanned dental casts. A visual guided registration is conducted starting by extracting corresponding features in both photographs and 3D scans. To achieve this, dental neck and occlusion surface are firstly extracted by image segmentation and 3D curvature analysis. Then, an iterative registration process is conducted during which feature positions are refined, guided by previously found anatomic edges. The occlusal edge image detection is improved by an original algorithm which follows Canny's poorly detected edges using a priori knowledge of tooth shapes. Finally, the influence of feature extraction and position optimization is evaluated in terms of the quality of the induced registration. Best combination of feature detection and optimization leads to a positioning average error of 1.10 mm and 2.03°.

  19. Example Applications of A Physically-Based 3D Surface-Subsurface Hydrologic Model Over Multiple Spatial and Temporal Scales

    NASA Astrophysics Data System (ADS)

    Sudicky, E. A.; Park, Y. J.; Hwang, H. T.; Berg, S.; Frey, S.

    2014-12-01

    It is now generally accepted within the scientific community that the climate is changing, and that future climate change may have significant impact on water resources in both quantity and quality. Alterations of base flow to rivers due to changing subsurface flow patterns, fluctuations in soil moisture and in the depth of the groundwater table, water levels in lakes and wetlands, and altered groundwater recharge/discharge patterns are examples of possible consequences of future climate change. In this presentation, our physically-based model, HydroGeoSphere (HGS), is first briefly described. It is a physically-based 3D control-volume finite element model representing 2D surface water flow and transport on the land surface together with 3D variably-saturated flow and transport in the subsurface. A globally implicit scheme used to solve the nonlinear surface and subsurface flow and transport equations simultaneously. The model can explicitly account for the hydrologic, solute and thermal interactions between surface and subsurface flow regimes as well as the atmospheric inputs in terms of air temperature, solar radiation and sensible/latent heat fluxes. A parallel computational framework has been implemented to facilitate model applications in high performance computing environments. The applicability of the model is demonstrated for a variety of problems, covering the hill slope scale to improve the understanding of the physical and chemical processes in the water cycle, to the assessment of the impact of climate change on water resources over the Canadian landmass in three dimensions. The climate-driven 3D basin-scale examples range from that of a highly characterized watershed in Southern Ontario having an area of about 7000 km2 to a large basin in Western Canada that covers an area of about 120,000 km2. The continental scale simulations explore the impacts of global climate change on Canada's surface and groundwater resources.

  20. Simulation of excimer laser micromachined 3D surface using a CAD solid modeling package

    NASA Astrophysics Data System (ADS)

    Hume, Richard G.; Iovenitti, Pio G.; Hayes, Jason P.; Harvey, Erol C.

    2002-11-01

    This paper describes the research on the development of a visualisation tool to generate 3D solid models of structures produced by micromachining using an excimer laser system. Currently, the development of part programs to achieve a desired microstructure is by a trial and error approach. This simulation tool assists designers and excimer machine programmers to produce microstructures using the excimer laser. Users can develop their microstructures and part programs with the assistance of digital prototypes rather than designing products using expensive laser micromachining equipment. The methods to simulate micromachining using the solid modelling package, SolidWorks, are described, and simulation and actual machined examples are reported. A basic knowledge of the solid modelling package is required to develop the simulations, and complex models take time to prepare, however, the development time can be minimised by working from previous simulations. The models developed can be parameterised so that families of designs can be investigated for little additional effort to optimise the design before committing to laser micromachining.

  1. Ocular surface temperature: a 3D FEM prediction using bioheat equation.

    PubMed

    Ng, E Y K; Ooi, E H

    2007-06-01

    Computational and mathematical human eye models from previous studies which were constructed in two-dimensions (2D) did not give a precise representation of the actual human eye. This work is an extension from an earlier published work on the 2D model. In this paper, a 3D FEM model of the human eye is simulated for the steady state temperature distribution during normal condition and during electromagnetic (EM) wave radiation. Results show a discrepancy of 0.49% for a normal condition as opposed to 1.9% of a 2D model when compared to experimental results from open literatures. Investigations on the EM wave radiations found an average power absorption density of 15,151 and 22,145 Wm(-3) for the 750 and 1500 MHz radiation, respectively. A peak temperature of 38.18( composite function)C was predicted for the 750 MHz radiation while 41.19( composite function)C was computed for the 1500 MHz radiation. These temperatures are in reasonable agreement with the simulated results computed by another report in the past. PMID:17034781

  2. View-independent Contour Culling of 3D Density Maps for Far-field Viewing of Iso-surfaces

    PubMed Central

    Feng, Powei; Ju, Tao; Warren, Joe

    2011-01-01

    In many applications, iso-surface is the primary method for visualizing the structure of 3D density maps. We consider a common scenario where the user views the iso-surfaces from a distance and varies the level associated with the iso-surface as well as the view direction to gain a sense of the general 3D structure of the density map. For many types of density data, the iso-surfaces associated with a particular threshold may be nested and never visible during this type of viewing. In this paper, we discuss a simple, conservative culling method that avoids the generation of interior portions of iso-surfaces at the contouring stage. Unlike existing methods that perform culling based on the current view direction, our culling is performed once for all views and requires no additional computation as the view changes. By pre-computing a single visibility map, culling is done at any iso-value with little overhead in contouring. We demonstrate the effectiveness of the algorithm on a range of bio-medical data and discuss a practical application in online visualization. PMID:21673830

  3. Water-repellent coatings for surface and 3D wood processing

    NASA Astrophysics Data System (ADS)

    Debelova, N. N.; Gorlenko, N. P.; Volokitin, G. G.; Sarkisov, Yu S.; Dmitriyenko, V. P.; Zavyalova, E. N.; Zavyalov, P. B.

    2015-01-01

    The paper presents the results of research in organic chemical compositions for hydrophobic protection of wood with the use of surface and three-dimensional coating techniques of impregnation and chemical compositions. Water absorption indicators, angles of contact on the surface of treated samples are detected herein. Kinetic equation of the moisture diffusion transition in capillary-porous structure of wood is suggested.

  4. 3D Printed Potential and Free Energy Surfaces for Teaching Fundamental Concepts in Physical Chemistry

    ERIC Educational Resources Information Center

    Kaliakin, Danil S.; Zaari, Ryan R.; Varganov, Sergey A.

    2015-01-01

    Teaching fundamental physical chemistry concepts such as the potential energy surface, transition state, and reaction path is a challenging task. The traditionally used oversimplified 2D representation of potential and free energy surfaces makes this task even more difficult and often confuses students. We show how this 2D representation can be…

  5. A full-field and real-time 3D surface imaging augmented DOT system for in-vivo small animal studies

    NASA Astrophysics Data System (ADS)

    Yi, Steven X.; Yang, Bingcheng; Yin, Gongjie

    2010-02-01

    A crucial parameter in Diffuse Optical Tomography (DOT) is the construction of an accurate forward model, which greatly depends on tissue boundary. Since photon propagation is a three-dimensional volumetric problem, extraction and subsequent modeling of three-dimensional boundaries is essential. Original experimental demonstration of the feasibility of DOT to reconstruct absorbers, scatterers and fluorochromes used phantoms or tissues confined appropriately to conform to easily modeled geometries such as a slab or a cylinder. In later years several methods have been developed to model photon propagation through diffuse media with complex boundaries using numerical solutions of the diffusion or transport equation (finite elements or differences) or more recently analytical methods based on the tangent-plane method . While optical examinations performed simultaneously with anatomical imaging modalities such as MRI provide well-defined boundaries, very limited progress has been done so far in extracting full-field (360 degree) boundaries for in-vivo three-dimensional DOT stand-alone imaging. In this paper, we present a desktop multi-spectrum in-vivo 3D DOT system for small animal imaging. This system is augmented with Technest's full-field 3D cameras. The built system has the capability of acquiring 3D object surface profiles in real time and registering 3D boundary with diffuse tomography. Extensive experiments are performed on phantoms and small animals by our collaborators at the Center for Molecular Imaging Research (CMIR) at Massachusetts General Hospital (MGH) and Harvard Medical School. Data has shown successful reconstructed DOT data with improved accuracy.

  6. A comparative DFT study of the catalytic activity of the 3d transition metal sulphides surfaces

    SciTech Connect

    Gomez-Balderas, R.; Oviedo-Roa, R; Martinez-Magadan, J M.; Amador, C.; Dixon, David A. )

    2002-10-10

    The catalytic activity of the first transition metal series sulphides for hydrodesulfurization (HDS) reactions exhibits a particular behaviour when analysed as a function of the metal position in the Periodic Table. This work reports a comparative study of the electronic structure of the bulk and of the (0 0 1) metal surface (assumed to be the reactive surface) for the Sc-Zn monosulphides. The systems were modeled using the NiAs prototype crystal structure for the bulk and by applying the supercell model with seven atomic layers for (0 0 1) surfaces. The electronic structure of closed-packed solids code based on the density-functional theory and adopting the muffin-tin approximation to the potential was employed in the calculations of the electronic properties. For the Co and Ni sulphides, the density of states (DOS) variations between the metal atom present in the bulk and the ones exposed at the surface show that at the surface, there exists a higher DOS in the occupied states region just below the Fermi level. This feature might indicate a good performance of these two metal sulphides substrates in the HDS reactions favouring a donation, back-donation mechanism. In contrast, the DOS at the surface of Mn is increased in the unoccupied states region, just above the Fermi level. This suggests the possibility of a strong interaction with charge dontating sulphur adsorbate atoms poisoning the active substrate surface.

  7. Free surface modeling in OWC chamber with parabolic side walls using 3D BEM

    SciTech Connect

    Hasanabad, Madjid Ghodsi

    2015-03-10

    In this paper, BEM was used for free surface modeling in OWC chamber and out of it. Linear kinematic and dynamic boundary conditions were used for free surface out of OWC chamber and nonlinear forms were used for free surface in the chamber. These boundary conditions were discretized by finite differences method. Also, some thermodynamics relations were applied for trapped air behavior modeling in OWC chamber. Wave specifications in Chabahar region were used in modeling because these waves have an acceptable power for electricity generation. The results show a good agreement with results of other researches.

  8. 3D surface analysis of hippocampal microvasculature in the irradiated brain.

    PubMed

    Craver, Brianna M; Acharya, Munjal M; Allen, Barrett D; Benke, Sarah N; Hultgren, Nan W; Baulch, Janet E; Limoli, Charles L

    2016-06-01

    Cranial irradiation used to control CNS malignancies can also disrupt the vasculature and impair neurotransmission and cognition. Here we describe two distinct methodologies for quantifying early and late radiation injury in CNS microvasculature. Intravascular fluorescently labeled lectin was used to visualize microvessels in the brain of the irradiated mouse 2 days post exposure and RECA-1 immunostaining was similarly used to visualize microvessels in the brain of the irradiated rat 1-month post exposure. Confocal microscopy, image deconvolution and 3-dimensional rendering methods were used to define vascular structure in a ∼4 × 10(7) μm(3) defined region of the brain. Quantitative analysis of these 3D images revealed that irradiation caused significant short- and long-term reductions in capillary density, diameter and volume. In mice, irradiation reduced mean vessel volume from 2,250 to 1,470 μm(3) and mean vessel diameter from 5.0 to 4.5 μm, resulting in significant reductions of 34% and 10%, in the hippocampus respectively. The number of vessel branch points and area was also found to also drop significantly in mice 2 days after irradiation. For rats, immunostaining revealed a significant, three-fold drop in capillary density 1 month after exposure compared to controls. Such radiation-induced disruption of the CNS microvasculature may be contributory if not causal to any number of neurocognitive side effects that manifest in cancer patients following cranial radiotherapy. This study demonstrates the utility of two distinct methodologies for quantifying these important adverse effects of radiotherapy. Environ. Mol. Mutagen. 57:341-349, 2016. © 2016 Wiley Periodicals, Inc. PMID:27175611

  9. A Coupled Finite-Volume Model for 2-D Surface and 3-D Subsurface Flows

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Surface-subsurface interactions are an intrinsic component of the hydrologic response within a watershed; therefore, hydrologic modeling tools should consider these interactions to provide reliable predictions, especially during rainfall-runoff processes. This paper presents a fully implicit coupled...

  10. Digitized crime scene forensics: automated trace separation of toolmarks on high-resolution 2D/3D CLSM surface data

    NASA Astrophysics Data System (ADS)

    Clausing, Eric; Vielhauer, Claus

    2015-03-01

    Locksmith forensics is an important and very challenging part of classic crime scene forensics. In prior work, we propose a partial transfer to the digital domain, to effectively support forensic experts and present approaches for a full process chain consisting of five steps: Trace positioning, 2D/3D acquisition with a confocal 3D laser scanning microscope, detection by segmentation, trace type determination, and determination of the opening method. In particular the step of trace segmentation on high-resolution 3D surfaces thereby turned out to be the part most difficult to implement. The reason for that is the highly structured and complex surfaces to be analyzed. These surfaces are cluttered with a high number of toolmarks, which overlap and distort each other. In Clausing et al., we present an improved approach for a reliable segmentation of relevant trace regions but without the possibility of separating single traces out of segmented trace regions. However, in our past research, especially features based on shape and dimension turned out to be highly relevant for a fully automated analysis and interpretation. In this paper, we consequently propose an approach for this separation. To achieve this goal, we use our segmentation approach and expand it with a combination of the watershed algorithm with a graph-based analysis. Found sub-regions are compared based on their surface character and are connected or divided depending on their similarity. We evaluate our approach with a test set of about 1,300 single traces on the exemplary locking cylinder component 'key pin' and thereby are able of showing the high suitability of our approach.

  11. A parallelized surface extraction algorithm for large binary image data sets based on an adaptive 3D delaunay subdivision strategy.

    PubMed

    Ma, Yingliang; Saetzler, Kurt

    2008-01-01

    In this paper we describe a novel 3D subdivision strategy to extract the surface of binary image data. This iterative approach generates a series of surface meshes that capture different levels of detail of the underlying structure. At the highest level of detail, the resulting surface mesh generated by our approach uses only about 10% of the triangles in comparison to the marching cube algorithm (MC) even in settings were almost no image noise is present. Our approach also eliminates the so-called "staircase effect" which voxel based algorithms like the MC are likely to show, particularly if non-uniformly sampled images are processed. Finally, we show how the presented algorithm can be parallelized by subdividing 3D image space into rectilinear blocks of subimages. As the algorithm scales very well with an increasing number of processors in a multi-threaded setting, this approach is suited to process large image data sets of several gigabytes. Although the presented work is still computationally more expensive than simple voxel-based algorithms, it produces fewer surface triangles while capturing the same level of detail, is more robust towards image noise and eliminates the above-mentioned "staircase" effect in anisotropic settings. These properties make it particularly useful for biomedical applications, where these conditions are often encountered. PMID:17993710

  12. Quantitative Evaluation of Tissue Surface Adaption of CAD-Designed and 3D Printed Wax Pattern of Maxillary Complete Denture

    PubMed Central

    Chen, Hu; Wang, Han; Lv, Peijun; Wang, Yong; Sun, Yuchun

    2015-01-01

    Objective. To quantitatively evaluate the tissue surface adaption of a maxillary complete denture wax pattern produced by CAD and 3DP. Methods. A standard edentulous maxilla plaster cast model was used, for which a wax pattern of complete denture was designed using CAD software developed in our previous study and printed using a 3D wax printer, while another wax pattern was manufactured by the traditional manual method. The cast model and the two wax patterns were scanned in the 3D scanner as “DataModel,” “DataWaxRP,” and “DataWaxManual.” After setting each wax pattern on the plaster cast, the whole model was scanned for registration. After registration, the deviations of tissue surface between “DataModel” and “DataWaxRP” and between “DataModel” and “DataWaxManual” were measured. The data was analyzed by paired t-test. Results. For both wax patterns produced by the CAD&RP method and the manual method, scanning data of tissue surface and cast surface showed a good fit in the majority. No statistically significant (P > 0.05) difference was observed between the CAD&RP method and the manual method. Conclusions. Wax pattern of maxillary complete denture produced by the CAD&3DP method is comparable with traditional manual method in the adaption to the edentulous cast model. PMID:26583108

  13. Holographic microscopy and microfluidics platform for measuring wall stress and 3D flow over surfaces textured by micro-pillars.

    PubMed

    Bocanegra Evans, Humberto; Gorumlu, Serdar; Aksak, Burak; Castillo, Luciano; Sheng, Jian

    2016-01-01

    Understanding how fluid flow interacts with micro-textured surfaces is crucial for a broad range of key biological processes and engineering applications including particle dispersion, pathogenic infections, and drag manipulation by surface topology. We use high-speed digital holographic microscopy (DHM) in combination with a correlation based de-noising algorithm to overcome the optical interference generated by surface roughness and to capture a large number of 3D particle trajectories in a microfluidic channel with one surface patterned with micropillars. It allows us to obtain a 3D ensembled velocity field with an uncertainty of 0.06% and 2D wall shear stress distribution at the resolution of ~65 μPa. Contrary to laminar flow in most microfluidics, we find that the flow is three-dimensional and complex for the textured microchannel. While the micropillars affect the velocity flow field locally, their presence is felt globally in terms of wall shear stresses at the channel walls. These findings imply that micro-scale mixing and wall stress sensing/manipulation can be achieved through hydro-dynamically smooth but topologically rough micropillars. PMID:27353632

  14. Holographic microscopy and microfluidics platform for measuring wall stress and 3D flow over surfaces textured by micro-pillars

    PubMed Central

    Bocanegra Evans, Humberto; Gorumlu, Serdar; Aksak, Burak; Castillo, Luciano; Sheng, Jian

    2016-01-01

    Understanding how fluid flow interacts with micro-textured surfaces is crucial for a broad range of key biological processes and engineering applications including particle dispersion, pathogenic infections, and drag manipulation by surface topology. We use high-speed digital holographic microscopy (DHM) in combination with a correlation based de-noising algorithm to overcome the optical interference generated by surface roughness and to capture a large number of 3D particle trajectories in a microfluidic channel with one surface patterned with micropillars. It allows us to obtain a 3D ensembled velocity field with an uncertainty of 0.06% and 2D wall shear stress distribution at the resolution of ~65 μPa. Contrary to laminar flow in most microfluidics, we find that the flow is three-dimensional and complex for the textured microchannel. While the micropillars affect the velocity flow field locally, their presence is felt globally in terms of wall shear stresses at the channel walls. These findings imply that micro-scale mixing and wall stress sensing/manipulation can be achieved through hydro-dynamically smooth but topologically rough micropillars. PMID:27353632

  15. Holographic microscopy and microfluidics platform for measuring wall stress and 3D flow over surfaces textured by micro-pillars

    NASA Astrophysics Data System (ADS)

    Bocanegra Evans, Humberto; Gorumlu, Serdar; Aksak, Burak; Castillo, Luciano; Sheng, Jian

    2016-06-01

    Understanding how fluid flow interacts with micro-textured surfaces is crucial for a broad range of key biological processes and engineering applications including particle dispersion, pathogenic infections, and drag manipulation by surface topology. We use high-speed digital holographic microscopy (DHM) in combination with a correlation based de-noising algorithm to overcome the optical interference generated by surface roughness and to capture a large number of 3D particle trajectories in a microfluidic channel with one surface patterned with micropillars. It allows us to obtain a 3D ensembled velocity field with an uncertainty of 0.06% and 2D wall shear stress distribution at the resolution of ~65 μPa. Contrary to laminar flow in most microfluidics, we find that the flow is three-dimensional and complex for the textured microchannel. While the micropillars affect the velocity flow field locally, their presence is felt globally in terms of wall shear stresses at the channel walls. These findings imply that micro-scale mixing and wall stress sensing/manipulation can be achieved through hydro-dynamically smooth but topologically rough micropillars.

  16. Study on the electronic structure and Fermi surface of 3d-transition-metal disilisides CoSi2

    NASA Astrophysics Data System (ADS)

    Hamid, A. S.

    2012-09-01

    We have investigated the electronic structure, the momentum density distribution ρ( p), and the Fermi surface FS of single crystals of the Pyrite-type 3d-transition-metal disilisides CoSi2. The band structure calculations, the density of states DOS, and the FS, in vicinity of Fermi level, have been carried out using the full-potential linearized augmented plane wave FP-LAPW method within generalized gradient approximation GGA for exchange and correlation potential. The measurements have been performed via the 2D angular correlation of annihilation radiation ACAR experiments. ρ( p) has been reconstructed by using the Fourier transformation technique. The FS has been reconstructed within the first Brillion zone BZ through the Locks, Crisp, and West LCW folding procedures. The analysis confirmed that Si 3 sp states hybrid with both Co 3 d- t 2 g and Co 3 d- e g states around Γ and X points, respectively. The dimensions of the FS of CoSi2 have been compared to the present calculations as well as to the earlier results.

  17. Hierarchical bioceramic scaffolds with 3D-plotted macropores and mussel-inspired surface nanolayers for stimulating osteogenesis

    NASA Astrophysics Data System (ADS)

    Xu, Mengchi; Zhai, Dong; Xia, Lunguo; Li, Hong; Chen, Shiyi; Fang, Bing; Chang, Jiang; Wu, Chengtie

    2016-07-01

    The hierarchical structure of biomaterials plays an important role in the process of tissue reconstruction and regeneration. 3D-plotted scaffolds have been widely used for bone tissue engineering due to their controlled macropore structure and mechanical properties. However, the lack of micro- or nano-structures on the strut surface of 3D-plotted scaffolds, especially for bioceramic scaffolds, limits their biological activity. Inspired by the adhesive versatility of mussels and the active ion-chelating capacity of polydopamine, we set out to prepare a hierarchical bioceramic scaffold with controlled macropores and mussel-inspired surface nanolayers by combining the 3D-plotting technique with the polydopamine/apatite hybrid strategy in order to synergistically accelerate the osteogenesis and angiogenesis. β-Tricalcium phosphate (TCP) scaffolds were firstly 3D-plotted and then treated in dopamine-Tris/HCl and dopamine-SBF solutions to obtain TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds, respectively. It was found that polydopamine/apatite hybrid nanolayers were formed on the surface of both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds and TCP-DOPA-SBF scaffolds induced apatite mineralization for the second time during the cell culture. As compared to TCP scaffolds, both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds significantly promoted the osteogenesis of bone marrow stromal cells (BMSCs) as well as the angiogenesis of human umbilical vein endothelial cells (HUVECs), and the TCP-DOPA-SBF group presented the highest in vitro osteogenic/angiogenic activity among the three groups. Furthermore, both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds significantly improved the formation of new bone in vivo as compared to TCP scaffolds without a nanostructured surface. Our results suggest that the utilization of a mussel-inspired Ca, P-chelated polydopamine nanolayer on 3D-plotted bioceramic scaffolds is a viable and effective strategy to construct a hierarchical structure for synergistically

  18. Hierarchical bioceramic scaffolds with 3D-plotted macropores and mussel-inspired surface nanolayers for stimulating osteogenesis

    NASA Astrophysics Data System (ADS)

    Xu, Mengchi; Zhai, Dong; Xia, Lunguo; Li, Hong; Chen, Shiyi; Fang, Bing; Chang, Jiang; Wu, Chengtie

    2016-07-01

    The hierarchical structure of biomaterials plays an important role in the process of tissue reconstruction and regeneration. 3D-plotted scaffolds have been widely used for bone tissue engineering due to their controlled macropore structure and mechanical properties. However, the lack of micro- or nano-structures on the strut surface of 3D-plotted scaffolds, especially for bioceramic scaffolds, limits their biological activity. Inspired by the adhesive versatility of mussels and the active ion-chelating capacity of polydopamine, we set out to prepare a hierarchical bioceramic scaffold with controlled macropores and mussel-inspired surface nanolayers by combining the 3D-plotting technique with the polydopamine/apatite hybrid strategy in order to synergistically accelerate the osteogenesis and angiogenesis. β-Tricalcium phosphate (TCP) scaffolds were firstly 3D-plotted and then treated in dopamine-Tris/HCl and dopamine-SBF solutions to obtain TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds, respectively. It was found that polydopamine/apatite hybrid nanolayers were formed on the surface of both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds and TCP-DOPA-SBF scaffolds induced apatite mineralization for the second time during the cell culture. As compared to TCP scaffolds, both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds significantly promoted the osteogenesis of bone marrow stromal cells (BMSCs) as well as the angiogenesis of human umbilical vein endothelial cells (HUVECs), and the TCP-DOPA-SBF group presented the highest in vitro osteogenic/angiogenic activity among the three groups. Furthermore, both TCP-DOPA-Tris and TCP-DOPA-SBF scaffolds significantly improved the formation of new bone in vivo as compared to TCP scaffolds without a nanostructured surface. Our results suggest that the utilization of a mussel-inspired Ca, P-chelated polydopamine nanolayer on 3D-plotted bioceramic scaffolds is a viable and effective strategy to construct a hierarchical structure for synergistically

  19. Surface-enhanced Raman spectroscopy in 3D electrospun nanofiber mats coated with gold nanorods.

    PubMed

    Camposeo, Andrea; Spadaro, Donatella; Magrì, Davide; Moffa, Maria; Gucciardi, Pietro G; Persano, Luana; Maragò, Onofrio M; Pisignano, Dario

    2016-02-01

    Nanofibers functionalized by metal nanostructures and particles are exploited as effective flexible substrates for surface-enhanced Raman scattering (SERS) analysis. Their complex three-dimensional structure may provide Raman signals enhanced by orders of magnitude compared to untextured surfaces. Understanding the origin of such improved performances is therefore very important for pushing nanofiber-based analytical technologies to their upper limit. Here, we report on polymer nanofiber mats which can be exploited as substrates for enhancing the Raman spectra of adsorbed probe molecules. The increased surface area and the scattering of light in the nanofibrous system are individually analyzed as mechanisms to enhance Raman scattering. The deposition of gold nanorods on the fibers further amplifies Raman signals due to SERS. This study suggests that Raman signals can be finely tuned in intensity and effectively enhanced in nanofiber mats and arrays by properly tailoring the architecture, composition, and light-scattering properties of the complex networks of filaments. PMID:26670770

  20. Data fusion for accurate microscopic rough surface metrology.

    PubMed

    Chen, Yuhang

    2016-06-01

    Data fusion for rough surface measurement and evaluation was analyzed on simulated datasets, one with higher density (HD) but lower accuracy and the other with lower density (LD) but higher accuracy. Experimental verifications were then performed on laser scanning microscopy (LSM) and atomic force microscopy (AFM) characterizations of surface areal roughness artifacts. The results demonstrated that the fusion based on Gaussian process models is effective and robust under different measurement biases and noise strengths. All the amplitude, height distribution, and spatial characteristics of the original sample structure can be precisely recovered, with better metrological performance than any individual measurements. As for the influencing factors, the HD noise has a relatively weaker effect as compared with the LD noise. Furthermore, to enable an accurate fusion, the ratio of LD sampling interval to surface autocorrelation length should be smaller than a critical threshold. In general, data fusion is capable of enhancing the nanometrology of rough surfaces by combining efficient LSM measurement and down-sampled fast AFM scan. The accuracy, resolution, spatial coverage and efficiency can all be significantly improved. It is thus expected to have potential applications in development of hybrid microscopy and in surface metrology. PMID:27058888

  1. Accurate registration of random radiographic projections based on three spherical references for the purpose of few-view 3D reconstruction

    SciTech Connect

    Schulze, Ralf; Heil, Ulrich; Weinheimer, Oliver; Gross, Daniel; Bruellmann, Dan; Thomas, Eric; Schwanecke, Ulrich; Schoemer, Elmar

    2008-02-15

    Precise registration of radiographic projection images acquired in almost arbitrary geometries for the purpose of three-dimensional (3D) reconstruction is beset with difficulties. We modify and enhance a registration method [R. Schulze, D. D. Bruellmann, F. Roeder, and B. d'Hoedt, Med. Phys. 31, 2849-2854 (2004)] based on coupling a minimum amount of three reference spheres in arbitrary positions to a rigid object under study for precise a posteriori pose estimation. Two consecutive optimization procedures (a, initial guess; b, iterative coordinate refinement) are applied to completely exploit the reference's shadow information for precise registration of the projections. The modification has been extensive, i.e., only the idea of using the sphere shadows to locate each sphere in three dimensions from each projection was retained whereas the approach to extract the shadow information has been changed completely and extended. The registration information is used for subsequent algebraic reconstruction of the 3D information inherent in the projections. We present a detailed mathematical theory of the registration process as well as simulated data investigating its performance in the presence of error. Simulation of the initial guess revealed a mean relative error in the critical depth coordinate ranging between 2.1% and 4.4%, and an evident error reduction by the subsequent iterative coordinate refinement. To prove the applicability of the method for real-world data, algebraic 3D reconstructions from few ({<=}9) projection radiographs of a human skull, a human mandible and a teeth-containing mandible segment are presented. The method facilitates extraction of 3D information from only few projections obtained from off-the-shelf radiographic projection units without the need for costly hardware. Technical requirements as well as radiation dose are low.

  2. Using High Frequency Focused Water-Coupled Ultrasound for 3-D Surface Depression Profiling

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Whalen, Mike F.; Hendricks, J. Lynne; Bodis, James R.

    1999-01-01

    Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. A prior study was performed demonstrating that focused air-coupled ultrasound at 1 MHz was capable of profiling surfaces with 25 micron depth resolution and 400 micron lateral resolution over a 1.4 mm depth range. In this article, the question of whether higher-frequency focused water-coupled ultrasound can improve on these specifications is addressed. 10 and 25 MHz focused ultrasonic transducers were employed in the water-coupled mode. Time-of-flight images of the sample surface were acquired and converted to depth / surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in water (V). Results are compared for the two frequencies used and with those from the 1 MHz air-coupled configuration.

  3. Duo gating on a 3D topological insulator - independent tuning of both topological surface states

    NASA Astrophysics Data System (ADS)

    Li, Chuan; de Ronde, Bob; Snelder, Marieke; Stehno, Martin; Huang, Yingkai; Golden, Mark; Brinkman, Alexander; ICE Team; IOP Collaboration

    ABSTRACT: Topological insulators are associated with a trove of exciting physics, such as the ability to host robust anyons, Majorana Bound States, which can be used for quantum computation. For future Majorana devices it is desirable to have the Fermi energy tuned as close as possible to the Dirac point of the topological surface state. Based on previous work on gating BSTS, we report the experimental progress towards gate-tuning of the top and bottom topological surface states of BiSbTeSe2 crystal flakes. When the Fermi level is moved across the Dirac point conduction is shown to change from electron dominated transport to hole dominated transport independently for either surface. In the high magnetic field, one can tune the system precisely between the different landau levels of both surfaces, thus a full gating map of the possible landau levels combination is established. In addition, we provide a simple capacitance model to explain the general hysteresis behaviors in topological insulator systems.

  4. A System to investigate 3-D droplet impact on leaf surfaces

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A system was developed to investigate droplet dynamic impact and retention on leaf surfaces. The system consisted of a uniform droplet generator, two high speed digital video cameras, a constant speed track, a leaf holder, and a cool light source. The droplet generator produced mono-sized droplets r...

  5. Experimental investigation and 3D-simulation of the ablated morphology of titanium surface using femtosecond laser pulses

    NASA Astrophysics Data System (ADS)

    Liu, Dong; Chen, Chuansong; Man, Baoyuan; Meng, Xue; Sun, Yanna; Li, Feifei

    2015-12-01

    The femtosecond laser ablated morphology on titanium surface is investigated theoretically and experimentally. A three dimensional two temperature model (3D-TTM) is used to simulate the surface morphology of titanium sample which is irradiated by femtosecond laser pulses. The electron heat capacity and electron-phonon coupling coefficient of titanium (transition metal) are complex temperature dependent, so the two parameters are corrected based on the theory of electron density of states (DOS). The model is solved by the finite difference time domain (FDTD) method. The 3D temperature field near the target surface is achieved. The radius and depth of the ablated crater are obtained based on the temperature field. The evolutions of the crate's radius and depth with laser fluence are discussed and compared with the experimental results. It is found that the back-flow of the molten material and the deposition of the material vapor should be responsible for the little discrepancy between the simulated and experimental results. The present work makes a better understanding of the thermodynamic process of femtosecond laser ablating metal and meanwhile provides an effective method tool to predict the micro manufacturing process on metals with femtosecond laser.

  6. Surface dynamics and breakdown patterns of a random solid subject to a biased 3D etching

    NASA Astrophysics Data System (ADS)

    Reverberi, A. P.; Maga, L.; Barbucci, A.; Bruzzone, A. G.

    2009-01-01

    We propose a selective disaggregation model in three dimensions with a mixed Brownian-deterministic motion of the etchant particle driven by a tuning parameter taking into account the presence of an external field. The width of the surface sites in saturation is described by the Edwards-Wilkinson scaling law as in a ballistic selective decay process. Besides, we consider the surfaces resulting when the solid substrate is completely eroded up to the electrical breakdown. In this situation, we analyse the effects of the etchant particle motion on the topology and conductivity of the residual substrate and we compare the relevant patterns with the ones related to the classical percolation theory. These results may interpret some recent experimental findings in electrochemical nanotechnology.

  7. Guided Evolution of Bulk Metallic Glass Nanostructures: A Platform for Designing 3D Electrocatalytic Surfaces.

    PubMed

    Doubek, Gustavo; Sekol, Ryan C; Li, Jinyang; Ryu, Won-Hee; Gittleson, Forrest S; Nejati, Siamak; Moy, Eric; Reid, Candy; Carmo, Marcelo; Linardi, Marcelo; Bordeenithikasem, Punnathat; Kinser, Emily; Liu, Yanhui; Tong, Xiao; Osuji, Chinedum O; Schroers, Jan; Mukherjee, Sundeep; Taylor, André D

    2016-03-01

    Electrochemical devices such as fuel cells, electrolyzers, lithium-air batteries, and pseudocapacitors are expected to play a major role in energy conversion/storage in the near future. Here, it is demonstrated how desirable bulk metallic glass compositions can be obtained using a combinatorial approach and it is shown that these alloys can serve as a platform technology for a wide variety of electrochemical applications through several surface modification techniques. PMID:26689722

  8. 3D shape measurements of fast moving rough surfaces by two tilted interference fringe systems

    NASA Astrophysics Data System (ADS)

    Kuschmierz, Robert; Günther, Philipp; Czarske, Jürgen W.

    2013-04-01

    Shape measurement of moving, especially rotating objects is an important task in the field of process control. The Laser Doppler Distance Sensor was invented for this purpose. It is realized by two tilted interference fringe systems and enables the simultaneous measurement of the surface velocity and profile. The distance is coded in the phase difference between the generated interference signals of two photo detectors. In order to achieve a distance uncertainty of below 1μm a steep calibration function is necessary. This can be achieved by increasing the tilting angle. However, due to the speckle effect at rough surfaces, random envelopes and phase jumps occur disturbing the phase difference estimation with increasing tilting angle. This problem was overcome recently by employing a receiving optics matching reducing the distance uncertainty by about one magnitude. By evaluating the Doppler frequencies of the two fringe systems the surface velocity and thereby the objects mean diameter can be calculated as well as angular misalignment of the sensor can be detected.

  9. Flexible range finding applied to 3D surface synthesis: A pseudo-trinocular approach

    NASA Astrophysics Data System (ADS)

    Hong, Tongminh

    An important area in machine vision and computer graphics is surface modeling, which involves the issue of data acquisition. A new range finding system is proposed which exploits perspective invariance (cross ratio), the targeting capability of structural lighting (slide projector), and epipolar planes' geometry (trinocular strategy). The system allows a fully autonomous calibration process and is highly efficient in terms of speed and accuracy. The system eliminates the ambiguity in disparity matching experienced in stereopsis, the extra image processing encountered in the trinocular system, the tedious reorganization of range data into a rectangular domain for surface modeling, and the scanning process of most active range finders that are not suitable for moving objects. Research described includes the development of several new camera calibration techniques, reformulation of the epipolar lines geometry method, and a rigorous study of the orientation constraints of the sensors (cameras and projector) in order to enhance the robustness of the vision system. The superiority of this new pseudo trinocular approach over the active structural lighting method and the passive binocular and/or trinocular techniques is convincing. It is believed that the proposed range finder has considerable potential for surface modeling.

  10. Prediction of 3D internal organ position from skin surface motion: results from electromagnetic tracking studies

    NASA Astrophysics Data System (ADS)

    Wong, Kenneth H.; Tang, Jonathan; Zhang, Hui J.; Varghese, Emmanuel; Cleary, Kevin R.

    2005-04-01

    An effective treatment method for organs that move with respiration (such as the lungs, pancreas, and liver) is a major goal of radiation medicine. In order to treat such tumors, we need (1) real-time knowledge of the current location of the tumor, and (2) the ability to adapt the radiation delivery system to follow this constantly changing location. In this study, we used electromagnetic tracking in a swine model to address the first challenge, and to determine if movement of a marker attached to the skin could accurately predict movement of an internal marker embedded in an organ. Under approved animal research protocols, an electromagnetically tracked needle was inserted into a swine liver and an electromagnetically tracked guidewire was taped to the abdominal skin of the animal. The Aurora (Northern Digital Inc., Waterloo, Canada) electromagnetic tracking system was then used to monitor the position of both of these sensors every 40 msec. Position readouts from the sensors were then tested to see if any of the movements showed correlation. The strongest correlations were observed between external anterior-posterior motion and internal inferior-superior motion, with many other axes exhibiting only weak correlation. We also used these data to build a predictive model of internal motion by taking segments from the data and using them to derive a general functional relationship between the internal needle and the external guidewire. For the axis with the strongest correlation, this model enabled us to predict internal organ motion to within 1 mm.

  11. 3D reconstruction of a patient-specific surface model of the proximal femur from calibrated x-ray radiographs: A validation study

    SciTech Connect

    Zheng Guoyan; Schumann, Steffen

    2009-04-15

    Twenty-three femurs (one plastic bone and twenty-two cadaver bones) with both nonpathologic and pathologic cases were considered to validate a statistical shape model based technique for three-dimensional (3D) reconstruction of a patient-specific surface model from calibrated x-ray radiographs. The 3D reconstruction technique is based on an iterative nonrigid registration of the features extracted from a statistically instantiated 3D surface model to those interactively identified from the radiographs. The surface models reconstructed from the radiographs were compared to the associated ground truths derived either from a 3D CT-scan reconstruction method or from a 3D laser-scan reconstruction method and an average error distance of 0.95 mm were found. Compared to the existing works, our approach has the advantage of seamlessly handling both nonpathologic and pathologic cases even when the statistical shape model that we used was constructed from surface models of nonpathologic bones.

  12. 3-D description of fracture surfaces and stress-sensitivity analysis for naturally fractured reservoirs

    SciTech Connect

    Zhang, S.Q.; Jioa, D.; Meng, Y.F.; Fan, Y.

    1997-08-01

    Three kinds of reservoir cores (limestone, sandstone, and shale with natural fractures) were used to study the effect of morphology of fracture surfaces on stress sensitivity. The cores, obtained from the reservoirs with depths of 2170 to 2300 m, have fractures which are mated on a large scale, but unmated on a fine scale. A specially designed photoelectric scanner with a computer was used to describe the topography of the fracture surfaces. Then, theoretical analysis of the fracture closure was carried out based on the fracture topography generated. The scanning results show that the asperity has almost normal distributions for all three types of samples. For the tested samples, the fracture closure predicted by the elastic-contact theory is different from the laboratory measurements because plastic deformation of the aspirates plays an important role under the testing range of normal stresses. In this work, the traditionally used elastic-contact theory has been modified to better predict the stress sensitivity of reservoir fractures. Analysis shows that the standard deviation of the probability density function of asperity distribution has a great effect on the fracture closure rate.

  13. Applications of neural networks to landmark detection in 3-D surface data

    NASA Astrophysics Data System (ADS)

    Arndt, Craig M.

    1992-09-01

    The problem of identifying key landmarks in 3-dimensional surface data is of considerable interest in solving a number of difficult real-world tasks, including object recognition and image processing. The specific problem that we address in this research is to identify the specific landmarks (anatomical) in human surface data. This is a complex task, currently performed visually by an expert human operator. In order to replace these human operators and increase reliability of the data acquisition, we need to develop a computer algorithm which will utilize the interrelations between the 3-dimensional data to identify the landmarks of interest. The current presentation describes a method for designing, implementing, training, and testing a custom architecture neural network which will perform the landmark identification task. We discuss the performance of the net in relationship to human performance on the same task and how this net has been integrated with other AI and traditional programming methods to produce a powerful analysis tool for computer anthropometry.

  14. Microstructure of Cu-Ag Uniform Nanoparticulate Films on Polyurethane 3D Catheters: Surface Properties.

    PubMed

    Rtimi, Sami; Sanjines, Rosendo; Pulgarin, Cesar; Kiwi, John

    2016-01-13

    The preparation, characterization, and antibacterial testing of Cu-Ag sputtered polyurethane (PU) catheters are addressed in this study. PU catheters with different atomic ratios Cu:Ag have been sputtered and led to different optical properties as followed by diffuse reflectance spectroscopy (DRS) and the surface redox properties were also different for different Cu-Ag ratios as observed by X-ray photoelectron spectroscopy (XPS). The surface atomic percentage concentration of the oxidized/reduced C-species originating from bacterial cultures before and after bacterial inactivation were determined on the Cu-Ag PU catheters. The crystallographic properties were determined by X-ray diffraction (XRD). The XRD-diffractogram showed the presence of Cu2O (111), Cu (200), CuO (020), and Ag (111) indicating that Cu nanoparticles present a more crystalline character compared to Ag nanoparticles. Increasing the percentage of Ag in the Cu-Ag films, bigger Ag-particle agglomerates were detected by scanning transmission electron microscopy (STEM) microanalysis confirming the results obtained by AFM. The bacterial inactivation kinetics of the sputtered Cu-Ag films on PU catheters was investigated in detail. Quasi-instantaneous bacterial inactivation kinetics was induced by the sputtered films on PU catheters after optimization of the Cu-Ag film thickness. PMID:26700113

  15. Laser electro-optic system for rapid three-dimensional /3-D/ topographic mapping of surfaces

    NASA Technical Reports Server (NTRS)

    Altschuler, M. D.; Altschuler, B. R.; Taboada, J.

    1981-01-01

    It is pointed out that the generic utility of a robot in a factory/assembly environment could be substantially enhanced by providing a vision capability to the robot. A standard videocamera for robot vision provides a two-dimensional image which contains insufficient information for a detailed three-dimensional reconstruction of an object. Approaches which supply the additional information needed for the three-dimensional mapping of objects with complex surface shapes are briefly considered and a description is presented of a laser-based system which can provide three-dimensional vision to a robot. The system consists of a laser beam array generator, an optical image recorder, and software for controlling the required operations. The projection of a laser beam array onto a surface produces a dot pattern image which is viewed from one or more suitable perspectives. Attention is given to the mathematical method employed, the space coding technique, the approaches used for obtaining the transformation parameters, the optics for laser beam array generation, the hardware for beam array coding, and aspects of image acquisition.

  16. Spontaneous development of arcuate single-sided subduction in global 3-D mantle convection models with a free surface

    NASA Astrophysics Data System (ADS)

    Crameri, Fabio; Tackley, Paul J.

    2014-07-01

    We present temporally evolving 3-D global mantle convection models with single-sided subduction and a free surface in both 3-D Cartesian and fully spherical geometry. Special focus is given to the spontaneous development of three-dimensional structures at the surface and in the upper mantle. We find that an arcuate shape is the natural form for trenches and slabs. Cartesian models are used first to study the dynamic evolution of subduction zones, spreading ridges, and interconnected transform features. These experiments highlight the strong variation of spontaneously developing, arcuate slab curvature and subduction polarity along the trench strike. The spontaneous development of spreading ridges leads to lateral offsets between separated segments that are characterized by normal transform motion. Spherical models then allow insights into the evolution of plate tectonics on a sphere. Investigated are the spontaneous evolution of slab geometry, trench motion, and subduction-induced mantle flow. Two new dynamical features are discovered: "back-slab spiral flow" and "slab tunneling." 2014. American Geophysical Union. All Rights Reserved.

  17. Design and fabrication of cast orthopedic implants with freeform surface textures from 3-D printed ceramic shell.

    PubMed

    Curodeau, A; Sachs, E; Caldarise, S

    2000-09-01

    Three-dimensional printing is a solid freeform fabrication process, which creates parts directly from a computer model. The parts are built by repetitively spreading a layer of powder and selectively joining the powder in the layer by ink-jet printing of a binder material. 3D printing was applied to the fabrication of sub-millimeter surface textures with overhang and undercut geometries for use in orthopedic prostheses as bony ingrowth structures. 3D printing is used to fabricate ceramic molds of alumina powder and silica binder, and these molds are used to cast the bony ingrowth surfaces of Co-Cr (ASTM F75) alloy. Minimum positive feature sizes of the ceramic mold and, therefore, minimum negative feature sizes of castings were determined to be approximately 200 x 200 x 175 microm and were limited by the strength of ceramic needed to withstand handling. Minimum negative feature sizes in the ceramic mold and, therefore, minimum positive features in the casting were found to be approximately 350 x 350 x 175 microm and were determined by limitations on removal of powder from the ceramic and the pressure required to fill these small features with molten metal during casting. Textures were designed with 5 layers of distinct geometric definition, allowing for the design of overhung geometry with overall porosity ranging from 30-70%. Features as small as 350 x 350 x 200 microm were included in these designs and successfully cast. PMID:10984701

  18. A new 3D grid method for accurate electronic structure calculation of polyatomic molecules: The Voronoi-cell finite difference method

    NASA Astrophysics Data System (ADS)

    Son, Sang-Kil; Chu, Shih-I.

    2008-05-01

    We introduce a new computational method on unstructured grids in the three-dimensional (3D) spaces to investigate the electronic structure of polyatomic molecules. The Voronoi-cell finite difference (VFD) method realizes a simple discrete Laplacian operator on unstructured grids based on Voronoi cells and their natural neighbors. The feature of unstructured grids enables us to choose intuitive pictures for an optimal molecular grid system. The new VFD method achieves highly adaptability by the Voronoi-cell diagram and yet simplicity by the finite difference scheme. It has no limitation in local refinement of grids in the vicinity of nuclear positions and provides an explicit expression at each grid without any integration. This method augmented by unstructured molecular grids is suitable for solving the Schr"odinger equation with the realistic 3D Coulomb potentials regardless of symmetry of molecules. For numerical examples, we test accuracies for electronic structures of one-electron polyatomic systems: linear H2^+ and triangular H3^++. We also extend VFD to the density functional theory (DFT) for many-electron polyatomic molecules.

  19. Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy

    SciTech Connect

    Gopan, Olga; Wu Qiuwen

    2012-10-01

    Purpose: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. Methods and Materials: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle{sup 3}, which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. Results: The maximum registration errors in AlignRT were 0.2 Degree-Sign for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1 Degree-Sign , 0.8 Degree-Sign , and 2.2 Degree-Sign in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9 Degree-Sign , 2.4 Degree-Sign , and 4.5 Degree-Sign and 10.1, 11.9, and 6.9 mm at 90% confidence level. Conclusions: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.

  20. Along-Arc Variation in Slab Surface Temperature Caused By 3D Material Circulation at the Plate Interface

    NASA Astrophysics Data System (ADS)

    Morishige, M.; Van Keken, P. E.

    2014-12-01

    In the northeast Japan arc, we can observe the along-arc variation of Quaternary volcano distribution, topography, seismic wave velocity, and Bouguer gravity anomaly whose characteristic wavelength is ~80 km. These observations may be related to 3D thermal structure in the mantle wedge and/or subducting Pacific slab. As a possible explanation of this, small-scale convection in the mantle wedge of thermal and chemical origin has been proposed so far. In this presentation, we will show another possible explanation for it. It is known mainly based on surface heat flow observation that the mantle wedge in this region is decoupled from the subducting Pacific slab down to ~80 km depth for geological time scale. We also observe that the down-dip limit of low angle thrust type earthquakes in this region is ~50 km depth. These suggest that in the northeast Japan arc, the mantle wedge and the slab decouples by brittle failure down to 50 km depth and by plastic deformation from 50 to 80 km depth. In order to test the effects of the plate interface on the thermal structure in this region, we construct 3D finite element models. The mantle flow is computed only in the mantle wedge, whereas temperature is computed for the whole model domain. We assume a thin, low viscosity layer just above the slab surface from 50 to 80 km depth to decouple the mantle wedge and the slab. We find that the along-arc variation in the slab surface temperature gradually develops with time. Its characteristic wavelength is ~100 km, which is comparable to or slightly higher than that observed. It arises because of the small-scale 3D circulation in the assumed low viscosity layer. The wavelength and the time of onset may depend on the viscosity and dimension of the low viscosity layer. Surface heat flow, on the other hand, does not show significant along-arc variation because forearc mantle is kept cold and hence rigid. These findings suggest that the observed along-arc variation in the northeast Japan

  1. Accurate 12D dipole moment surfaces of ethylene

    NASA Astrophysics Data System (ADS)

    Delahaye, Thibault; Nikitin, Andrei V.; Rey, Michael; Szalay, Péter G.; Tyuterev, Vladimir G.

    2015-10-01

    Accurate ab initio full-dimensional dipole moment surfaces of ethylene are computed using coupled-cluster approach and its explicitly correlated counterpart CCSD(T)-F12 combined respectively with cc-pVQZ and cc-pVTZ-F12 basis sets. Their analytical representations are provided through 4th order normal mode expansions. First-principles prediction of the line intensities using variational method up to J = 30 are in excellent agreement with the experimental data in the range of 0-3200 cm-1. Errors of 0.25-6.75% in integrated intensities for fundamental bands are comparable with experimental uncertainties. Overall calculated C2H4 opacity in 600-3300 cm-1 range agrees with experimental determination better than to 0.5%.

  2. Modeling the Morphogenesis of Epidermal Tissues on the Surface of a 3D Last

    NASA Astrophysics Data System (ADS)

    McCleery, W. Tyler; Crews, Sarah M.; Mashburn, David N.; Veldhuis, Jim; Brodland, G. Wayne; Hutson, M. Shane

    2014-03-01

    Embryogenesis in the fruit fly Drosophila melanogaster is coordinated by the interaction of cells in adjacent tissues. For some events of embryogenesis, e.g., dorsal closure, two-dimensional models have been sufficient to elucidate the relevant cell and tissue mechanics. Here, we describe a new three-dimensional cell-level finite element model for investigating germ band retraction - a morphogenetic event where one epidermal tissue, the germ band, initially wraps around the posterior end of the ellipsoidal embryo. This tissue then retracts with a mechanical assist from contraction of cells in a second epidermal tissue, the amnioserosa. To speed simulation run times and focus on the relevant tissues, we only model epidermal tissue interactions. Epidermal cells are defined as polygons constrained to lie on the surface of the ellipsoidal last, but have adjustable parameters such as edge tensions and cell pressures. Tissue movements are simulated by balancing these dynamic cell-level forces with viscous resistance and allowing cells to exchange neighbors. Our choice of modeling parameters is informed by in vivo measurements of cell-level forces using laser microsurgery. We use this model to investigate the multicellular stress fields in normal and aberrant development.

  3. 3D near-surface soil response from H/V ambient-noise ratios

    USGS Publications Warehouse

    Wollery, E.W.; Street, R.

    2002-01-01

    The applicability of the horizontal-to-vertical (H/V) ambient-noise spectral ratio for characterizing earthquake site effects caused by nearsurface topography and velocity structures was evaluated at sites underlain by thick (i.e. >100 m) sediment deposits near the southern-end of the New Madrid seismic zone in the central United States. Three-component ambient-noise and velocity models derived from seismic (shearwave) refraction/reflection surveys showed that a relatively horizontal, sharp shear-wave velocity interface in the soil column resulted in an H/V spectral ratio with a single well-defined peak. Observations at sites with more than one sharp shear-wave velocity contrast and horizontally arranged soil layers resulted in at least two well-defined H/V spectral ratio peaks. Furthermore, at sites where there were sharp shear-wave velocity contrasts in nonhorizontal, near-surface soil layers, the H/V spectra exhibited a broad-bandwidth, relatively low amplitude signal instead of a single well-defined peak. ?? 2002 Elsevier Science Ltd. All rights reserved.

  4. The effects of surface gloss and roughness on color constancy for real 3-D objects.

    PubMed

    Granzier, Jeroen J M; Vergne, Romain; Gegenfurtner, Karl R

    2014-01-01

    Color constancy denotes the phenomenon that the appearance of an object remains fairly stable under changes in illumination and background color. Most of what we know about color constancy comes from experiments using flat, matte surfaces placed on a single plane under diffuse illumination simulated on a computer monitor. Here we investigate whether material properties (glossiness and roughness) have an effect on color constancy for real objects. Subjects matched the color and brightness of cylinders (painted red, green, or blue) illuminated by simulated daylight (D65) or by a reddish light with a Munsell color book illuminated by a tungsten lamp. The cylinders were either glossy or matte and either smooth or rough. The object was placed in front of a black background or a colored checkerboard. We found that color constancy was significantly higher for the glossy objects compared to the matte objects, and higher for the smooth objects compared to the rough objects. This was independent of the background. We conclude that material properties like glossiness and roughness can have significant effects on color constancy. PMID:24563527

  5. Unified system for holographic measurement in fluid and solid mechanics: use of the system for 3D displacement measurement on surfaces

    NASA Astrophysics Data System (ADS)

    Barnhart, Donald H.; Chan, Victor S. S.; Halliwell, Neil A.; Coupland, Jeremy M.

    1999-10-01

    This paper reports the use of a new holographic measurement system in the study of 3D surface displacements. Although equally applicable to fluid and solid mechanics, the aim of this report is to demonstrate the system's use in quantitative surface displacement measurements with a classical cantilever experiment, using a continuous-wave diode-pumped YAG laser system. The reported results exhibit an accuracy corresponding to other interferometric systems, but with a much larger displacement range. The measurement system employs a novel optical image shifting method to eliminate the problem of directional ambiguity. In addition, the reported system uses 3D complex correlation rather than 2D real correlation, thereby offering a direct method for measuring 3D displacement in 3D space. FInally, with the novel use of an optical fiber to probe the recorded holographic image space, it is found to be a simple matter to directly obtain 3D displacement measurements at precisely known surface locations.

  6. Regional magnetic anomaly fields: 3D Taylor polynomial and surface spline models

    NASA Astrophysics Data System (ADS)

    Feng, Yan; Jiang, Yong; Jiang, Yi; Li, Zheng; Jiang, Jin; Liu, Zhong-Wei; Ye, Mei-Chen; Wang, Hong-Sheng; Li, Xiu-Ming

    2016-03-01

    We used data from 1960.0, 1970.0, 1980.0, 1990.0, and 2000.0 to study the geomagnetic anomaly field over the Chinese mainland by using the three-dimensional Taylor polynomial (3DTP) and the surface spline (SS) models. To obtain the pure anomaly field, the main field and the induced field of the ionospheric and magnetospheric fields were removed from measured data. We also compared the SS model anomalies and the data obtained with Kriging interpolation (KI). The geomagnetic anomaly distribution over the mainland was analyzed based on the SS and 3DTP models by transferring all points from 1960.0-1990.0 to 2000.0. The results suggest that the total intensity F anomalies estimated based on the SS and KI for each year are basically consistent in distribution and intensity. The anomalous distributions in the X-, Y-, and Z-direction and F are mainly negative. The 3DTP model anomalies suggest that the intensity in the X-direction increases from -100 nT to 0 nT with longitude, whereas the intensity in the Y-direction decreases from 400 nT to 20 nT with longitude and over the eastern mainland is almost negative. The intensity in the Z-direction and F are very similar and in most areas it is about -50nT and higher in western Tibet. The SS model anomalies overall reflect the actual distribution of the magnetic field anomalies; however, because of the uneven distribution of measurements, it yields several big anomalies. Owing to the added altitude term, the 3DTP model offers higher precision and is consistent with KI.

  7. 3-D surface profile measurements of large x-ray synchrotron radiation mirrors using stitching interferometry.

    SciTech Connect

    Assoufid, L.; Bray, M.; Qian, J.; Shu, D.

    2002-09-12

    Stitching interferometry, using small-aperture, high-resolution, phase-measuring interferometry, has been proposed for quite some time now as a metrology technique to obtain 3-dimensional profiles of surfaces of oversized optical components and substrates. The aim of this work is to apply this method to the specific case of long grazing-incidence x-ray mirrors, such as those used in beamlines at synchrotron radiation facilities around the world. Both fabrication and characterization of these mirrors would greatly benefit from this technique because it offers the potential for providing measurements with accuracy and resolution better than those obtained using existing noncontact laser profilers, such as the long trace profiler (LTP). Measurement data can be used as feedback for computer-controlled fabrication processes to correct for possible topography errors. The data can also be used for simulating and predicting mirror performance under realistic conditions. A semiautomated stitching system was built and tested at the X-ray Optics Metrology Laboratory of the Advanced Photon Source at Argonne National Laboratory. The initial objective was to achieve a measurement sensitivity on the order of 1 {micro}rad rms. Preliminary tests on a 1 m-long x-ray mirror showed system repeatability of less than 0.6 {micro}rad rms. This value is comparable to that of a conventional LTP. The measurement accuracy was mostly affected by environmental perturbations and system calibration effects. With a fully automated and improved system (to be built in the near future), we expect to achieve measurement sensitivity on the order of 0.0 {micro}rad rms or better. In this paper, after a brief review of basic principles and general technical difficulties and challenges of the stitching technique, a detailed description of the measurement setup is given and preliminary results obtained with it are analyzed and discussed.

  8. Voxelization algorithms for geospatial applications: Computational methods for voxelating spatial datasets of 3D city models containing 3D surface, curve and point data models.

    PubMed

    Nourian, Pirouz; Gonçalves, Romulo; Zlatanova, Sisi; Ohori, Ken Arroyo; Vu Vo, Anh

    2016-01-01

    Voxel representations have been used for years in scientific computation and medical imaging. The main focus of our research is to provide easy access to methods for making large-scale voxel models of built environment for environmental modelling studies while ensuring they are spatially correct, meaning they correctly represent topological and semantic relations among objects. In this article, we present algorithms that generate voxels (volumetric pixels) out of point cloud, curve, or surface objects. The algorithms for voxelization of surfaces and curves are a customization of the topological voxelization approach [1]; we additionally provide an extension of this method for voxelization of point clouds. The developed software has the following advantages:•It provides easy management of connectivity levels in the resulting voxels.•It is not dependant on any external library except for primitive types and constructs; therefore, it is easy to integrate them in any application.•One of the algorithms is implemented in C++ and C for platform independence and efficiency. PMID:27408832

  9. Cross-Modality Validation of Acetabular Surface Models Using 3-D Ultrasound Versus Magnetic Resonance Imaging in Normal and Dysplastic Infant Hips.

    PubMed

    Diederichs, Chad; Heath, Alana; Hareendranathan, Abhilash R; Zonoobi, Dornoosh; Kuntze, Gregor; Dulai, Sukhdeep; Mabee, Myles G; Ronsky, Janet L; Jaremko, Jacob L

    2016-09-01

    Current imaging diagnosis of developmental dysplasia of the hip (DDH) in infancy relies on 2-D ultrasound (US), which is highly operator-dependent. 3-D US offers more complete, and potentially more reliable, imaging of infant hip geometry. We sought to validate the fidelity of acetabular surface models obtained by 3-D US against those obtained concurrently by magnetic resonance imaging (MRI). 3-D US and MRI scans were performed on the same d in 20 infants with normal to severely dysplastic hips (mean age, 57 d; range 13-181 d). 3-D US was performed by two observers using a Philips VL13-5 probe. Coronal 3-D multi-echo data image combination (MEDIC) magnetic resonance (MR) images (1-mm slice thickness) were obtained, usually without sedation, in a 1.5 T Siemens unit. Acetabular surface models were generated for 40 hips from 3-D US and MRI using semi-automated tracing software, separately by three observers. For each hip, the 3-D US and MRI models were co-registered to overlap as closely as possible using Amira software, and the root mean square (RMS) distances between points on the models were computed. 3-D US scans took 3.2 s each. Inter-modality variability was visually minimal. Mean RMS distance between corresponding points on the acetabular surface at 3-D US and MRI was 0.4 ± 0.3 mm, with 95% confidence interval <1 mm. Mean RMS errors for inter-observer and intra-observer comparisons were significantly less for 3-D US than for MRI, while inter-scan and inter-modality comparisons showed no significant difference. Acetabular geometry was reproduced by 3-D US surface models within 1 mm of the corresponding 3-D MRI surface model, and the 3-D US models were more reliable. This validates the fidelity of 3-D US modeling and encourages future use of 3-D US in assessing infant acetabulum anatomy, which may be useful to detect and monitor treatment of hip dysplasia. PMID:27209429

  10. On the Finite-Time Splash and Splat Singularities for the 3-D Free-Surface Euler Equations

    NASA Astrophysics Data System (ADS)

    Coutand, Daniel; Shkoller, Steve

    2014-01-01

    We prove that the 3-D free-surface incompressible Euler equations with regular initial geometries and velocity fields have solutions which can form a finite-time "splash" (or "splat") singularity first introduced in Castro et al. (Splash singularity for water waves, http://arxiv.org/abs/1106.2120v2, 2011), wherein the evolving 2-D hypersurface, the moving boundary of the fluid domain, self-intersects at a point (or on surface). Such singularities can occur when the crest of a breaking wave falls unto its trough, or in the study of drop impact upon liquid surfaces. Our approach is founded upon the Lagrangian description of the free-boundary problem, combined with a novel approximation scheme of a finite collection of local coordinate charts; as such we are able to analyze a rather general set of geometries for the evolving 2-D free-surface of the fluid. We do not assume the fluid is irrotational, and as such, our method can be used for a number of other fluid interface problems, including compressible flows, plasmas, as well as the inclusion of surface tension effects.

  11. Effect of a glaze/composite sealant on the 3-D surface roughness of esthetic restorative materials.

    PubMed

    Perez, Cesar dos Reis; Hirata, Raphael Júnior; da Silva, Antonio Henrique Monteiro da Fonseca Thomé; Sampaio, Eduardo Martins; de Miranda, Mauro Sayão

    2009-01-01

    The main goal of the current study was to evaluate the surface roughness of tooth-colored restorative materials after different finishing/polishing protocols, including a liquid polisher (BisCover, BISCO, Schaumburg, IL, USA). The restorative materials tested included two nanofilled resin composites (Filtek Supreme, 3M Dental Products, St Paul, MN, USA and Grandio, Voco, Cuxhaven, Germany), one resin-modified glass ionomer cement (Vitremer, 3M Dental Products) and one conventional glass ionomer cement (Meron Molar ART, Voco). The finishing/polishing methods were divided into five groups: G1 (compression with Mylar matrix), G2 (finishing with diamond burs), G3 (Sof-Lex, 3M Dental Products), G4 (BisCover, BISCO, after diamond burs) and G5 (BisCover after Sof-Lex). Five cylindrical specimens of each material were prepared for each group according to the manufacturer's instructions. The finishing/polishing methods were performed by a single operator in one direction to avoid variations at low speed (15,000 RPM). The surface roughness was evaluated using a 3-D scanning instrument with two parameters considered (Ra and Rz). The data was analyzed using one-way ANOVA followed by a multiple comparison Tukey's test. The results showed that BisCover (BISCO) was capable of reducing surface roughness and provided polished surfaces for all materials, enhancing smoothness over already polished surfaces (Sof-Lex, 3M Dental Products) and achieving polishing after finishing with diamond burs. PMID:19953776

  12. 3D profilometric characterization of the aged skin surface using a skin replica and alicona Mex software.

    PubMed

    Pirisinu, Marco; Mazzarello, Vittorio

    2016-05-01

    The skin's surface is characterized by a network of furrows and wrinkles showing different height and depth. Different studies showed that processes such as aging, photo aging and cancer may alter dermal ultrastructure surface. The quantitative analysis of skin topography is a key point for understanding health condition of the skin. Here, for the first time, the skin fine structure was studied via a new approach where replica method was combined with Mex Alicona software and scanning electron microscopy (SEM). The skin texture of cheek and forearm were studied in 120 healthy sardinian volunteers. Patients were divided into three different aged groups. The skin areas of interest were reproduced by the silicone replica method, each replica was explored by SEM and digital images were taken. By using Mex Alicona software were created 3D imagine and a list of 24 surface texture parameters were obtained, of these the most representative were chosen in order to assess eventual changes between groups. The skin's texture of forearm and cheek showed a gradually loss of its typical polyhedric mesh with increasing age group. In particular, the photoexposition increased loss of dermal texture. At today, Alicona mex technology was exclusively used on palaeontology studies, our results showed that a deep analyze of skin texture was performed and support Mex alicona software as a new promising tool on dermatological research. This new analytical approach provided an easy and fast process to appreciate skin texture and its changes, by using high quality 3D dimension images. SCANNING 38:213-220, 2016. © 2015 Wiley Periodicals, Inc. PMID:26258960

  13. 3-D earthquake surface displacements from differencing pre- and post-event LiDAR point clouds

    NASA Astrophysics Data System (ADS)

    Krishnan, A. K.; Nissen, E.; Arrowsmith, R.; Saripalli, S.

    2012-12-01

    The explosion in aerial LiDAR surveying along active faults across the western United States and elsewhere provides a high-resolution topographic baseline against which to compare repeat LiDAR datasets collected after future earthquakes. We present a new method for determining 3-D coseismic surface displacements and rotations by differencing pre- and post-earthquake LiDAR point clouds using an adaptation of the Iterative Closest Point (ICP) algorithm, a point set registration technique widely used in medical imaging, computer vision and graphics. There is no need for any gridding or smoothing of the LiDAR data and the method works well even with large mismatches in the density of the two point clouds. To explore the method's performance, we simulate pre- and post-event point clouds using real ("B4") LiDAR data on the southern San Andreas Fault perturbed with displacements of known magnitude. For input point clouds with ~2 points per square meter, we are able to reproduce displacements with a 50 m grid spacing and with horizontal and vertical accuracies of ~20 cm and ~4 cm. In the future, finer grids and improved precisions should be possible with higher shot densities and better survey geo-referencing. By capturing near-fault deformation in 3-D, LiDAR differencing with ICP will complement satellite-based techniques such as InSAR which map only certain components of the surface deformation and which often break down close to surface faulting or in areas of dense vegetation. It will be especially useful for mapping shallow fault slip and rupture zone deformation, helping inform paleoseismic studies and better constrain fault zone rheology. Because ICP can image rotations directly, the technique will also help resolve the detailed kinematics of distributed zones of faulting where block rotations may be common.

  14. Surface topography induces 3D self-orientation of cells and extracellular matrix resulting in improved tissue function†

    PubMed Central

    Guillemette, Maxime D.; Cui, Bo; Roy, Emmanuel; Gauvin, Robert; Giasson, Claude J.; Esch, Mandy B.; Carrier, Patrick; Deschambeault, Alexandre; Dumoulin, Michel; Toner, Mehmet; Germain, Lucie; Veres, Teodor

    2015-01-01

    The organization of cells and extracellular matrix (ECM) in native tissues plays a crucial role in their functionality. However, in tissue engineering, cells and ECM are randomly distributed within a scaffold. Thus, the production of engineered-tissue with complex 3D organization remains a challenge. In the present study, we used contact guidance to control the interactions between the material topography, the cells and the ECM for three different tissues, namely vascular media, corneal stroma and dermal tissue. Using a specific surface topography on an elastomeric material, we observed the orientation of a first cell layer along the patterns in the material. Orientation of the first cell layer translates into a physical cue that induces the second cell layer to follow a physiologically consistent orientation mimicking the structure of the native tissue. Furthermore, secreted ECM followed cell orientation in every layer, resulting in an oriented self-assembled tissue sheet. These self-assembled tissue sheets were then used to create 3 different structured engineered-tissue: cornea, vascular media and dermis. We showed that functionality of such structured engineered-tissue was increased when compared to the same qnon-structured tissue. Dermal tissues were used as a negative control in response to surface topography since native dermal fibroblasts are not preferentially oriented in vivo. Non-structured surfaces were also used to produce randomly oriented tissue sheets to evaluate the impact of tissue orientation on functional output. This novel approach for the production of more complex 3D tissues would be useful for clinical purposes and for in vitro physiological tissue model to better understand long standing questions in biology. PMID:20023803

  15. Change of Re dependency of single bubble 3D motion by surface slip condition in surfactant solution

    NASA Astrophysics Data System (ADS)

    Tagawa, Yoshiyuki; Funakubo, Ami; Takagi, Shu; Matsumoto, Yoichiro

    2009-11-01

    Path instability of single bubble in water is sensitive to surfactant. One of the key effects of surfactant is to decrease bubble rising velocity (i.e. increase drag) and change bubble slip condition from free-slip to no-slip. This phenomenon is described as Marangoni effect. However, the surfactant eff