Science.gov

Sample records for accurate diagnostic procedures

  1. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures.

    PubMed

    Brahme, Anders; Nyman, Peter; Skatt, Björn

    2008-05-01

    A four-dimensional (4D) laser camera (LC) has been developed for accurate patient imaging in diagnostic and therapeutic radiology. A complementary metal-oxide semiconductor camera images the intersection of a scanned fan shaped laser beam with the surface of the patient and allows real time recording of movements in a three-dimensional (3D) or four-dimensional (4D) format (3D +time). The LC system was first designed as an accurate patient setup tool during diagnostic and therapeutic applications but was found to be of much wider applicability as a general 4D photon "tag" for the surface of the patient in different clinical procedures. It is presently used as a 3D or 4D optical benchmark or tag for accurate delineation of the patient surface as demonstrated for patient auto setup, breathing and heart motion detection. Furthermore, its future potential applications in gating, adaptive therapy, 3D or 4D image fusion between most imaging modalities and image processing are discussed. It is shown that the LC system has a geometrical resolution of about 0, 1 mm and that the rigid body repositioning accuracy is about 0, 5 mm below 20 mm displacements, 1 mm below 40 mm and better than 2 mm at 70 mm. This indicates a slight need for repeated repositioning when the initial error is larger than about 50 mm. The positioning accuracy with standard patient setup procedures for prostate cancer at Karolinska was found to be about 5-6 mm when independently measured using the LC system. The system was found valuable for positron emission tomography-computed tomography (PET-CT) in vivo tumor and dose delivery imaging where it potentially may allow effective correction for breathing artifacts in 4D PET-CT and image fusion with lymph node atlases for accurate target volume definition in oncology. With a LC system in all imaging and radiation therapy rooms, auto setup during repeated diagnostic and therapeutic procedures may save around 5 min per session, increase accuracy and allow

  2. Diagnostic procedures in immunodermatology.

    PubMed

    Cormane, R H; Asghar, S S

    1976-07-01

    gold or radiolabeled glucosamine. In contact allergic dermatitis, an increase in the IgD-bearing lymphocytes and granulocytes has also been correlated with cellular hypersensitivity. Lymphocytes and polymorphonuclear leukocytes coated with antibodies mainly directed against nuclear antigens of the basal layer cells of the noninvolved epidermis have invariably been encountered in psoriasis. The use of these findings for diagnostic purposes and for understanding the mechanisms of certain diseases is being explored.

  3. Clonal complexity in Mycobacterium tuberculosis can hamper diagnostic procedures.

    PubMed

    Pérez-Lago, Laura; Herranz, Marta; Navarro, Yurena; Ruiz Serrano, María Jesús; Miralles, Pilar; Bouza, Emilio; García-de-Viedma, Darío

    2017-02-15

    Clonal complexity is increasingly accepted in Mycobacterium tuberculosis infection, including mixed infections by ≥2 strains, which usually occur in settings with a high burden of tuberculosis and/or a high risk of overexposure to infected patients. Mixed infections can hamper diagnostic procedures: obtaining an accurate antibiogram is difficult when the susceptibility patterns of the strains differ. Here, we show how mixed infections can also prove challenging for other diagnostic procedures, even outside settings where mixed infections are traditionally expected. We show how an unnoticed mixed infection in an HIV-positive patient diagnosed in Madrid, Spain, with differences in the representativeness of the coinfecting strains in different sputum samples, markedly complicated the resolution of a laboratory cross-contamination false-positivity alert.

  4. Diagnostic procedures for osteoporosis in the elderly.

    PubMed

    Delmas, P D

    1995-01-01

    Several recent studies show that bone loss continues in the elderly, and that various regimens are still effective in the elderly to stop bone loss. Thus, diagnostic procedures for osteoporosis should be considered in elderly women, i.e. measurement of bone mass by dual energy X-ray absorptiometry of the hip, spine or forearm that have been shown to predict the subsequent risk of fractures. The rate of bone turnover, and therefore of bone loss, is quite variable from patient to patient and can be assessed with improved sensitivity and specificity with the new markers that are specific for bone formation and bone resorption.

  5. Cancer Risks Associated with External Radiation From Diagnostic Imaging Procedures

    PubMed Central

    Linet, Martha S.; Slovis, Thomas L.; Miller, Donald L.; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; de Gonzalez, Amy Berrington

    2012-01-01

    The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate widespread use of evidence-based appropriateness criteria for decisions about imaging procedures, oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives, development of electronic lifetime records of imaging procedures for patients and their physicians, and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures. PMID:22307864

  6. Cancer risks associated with external radiation from diagnostic imaging procedures.

    PubMed

    Linet, Martha S; Slovis, Thomas L; Miller, Donald L; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; Berrington de Gonzalez, Amy

    2012-01-01

    The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but increased potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate the widespread use of evidence-based appropriateness criteria for decisions about imaging procedures; oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives; development of electronic lifetime records of imaging procedures for patients and their physicians; and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures.

  7. Unproven diagnostic procedures in IgE-mediated allergic diseases.

    PubMed

    Niggemann, B; Grüber, C

    2004-08-01

    A considerable body of literature on therapeutic aspects of complementary and alternative medicine has been published in recent years, but little is known on diagnostic procedures. This short review lists complementary and alternative diagnostic procedures for the diagnosis of allergic diseases and presents an assessment of their usefulness for the daily practice. The review of the literature revealed that neither the determination of specific immunoglobulin G-antibodies in serum, the hair-analysis, the cytotoxic test, kinesiology, iridology, or electrodermal testing represent useful tests for the daily practice. To date, no complementary or alternative diagnostic procedure can be recommended as a meaningful element in the diagnostic work-up of allergic diseases. This is especially true for food allergy: properly performed oral food challenges still represent the gold standard for implementing specific diets in food allergic individuals. Ineffective diagnostic approaches may be costly for the consumer and delay appropriate therapy.

  8. Diagnostic Procedures to Detect Chlamydia trachomatis Infections

    PubMed Central

    Meyer, Thomas

    2016-01-01

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections. PMID:27681919

  9. Dynamic diagnostic and decision procedures under uncertainty

    SciTech Connect

    Baranov, V.V.

    1995-01-01

    In this paper, we consider uncertainty that arises when the true state x {element_of} E is not accessible to direct observation and remains unknown. Instead, we observe some features {theta} {element_of} {Theta} that carry a certain information about the true state. This information is described by the conditional distribution P({Theta}{vert_bar}E), which we call the linkage distribution. Regarding this distribution we assume that it exists but is unknown. This leads to uncertainty with respect to states from E and the linkage distribution P({Theta}{vert_bar}E), which we denote by NEP. The substantive problem can be stated as follows: from observations of the features {theta}{element_of}{Theta} made at each time instant n = 1,2,...,recognize the state x {element_of} E, identify the linkage distribution P, and use the results of recognition and identification to choose a decision y {element_of} Y so that the decision process is optimal in some sense. State recognition is the subject of diagnostics. The uncertainty NEP thus generates a problem of diagnostics and dynamic decision making.

  10. Diagnostic Procedures to Detect Chlamydia trachomatis Infections.

    PubMed

    Meyer, Thomas

    2016-08-05

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections.

  11. Peritoneal lavage and other diagnostic procedures in blunt abdominal trauma

    SciTech Connect

    Burney, R.E.

    1986-08-01

    Diagnostic procedures such as peritoneal lavage, computed tomography, emergency angiography, nuclear scintigraphy, and contrast studies of the gastrointestinal and urinary tracts can assist in the identification, quantification, and localization of injury after blunt abdominal trauma. Use of these procedures should be determined by careful clinically assessment as part of an aggressive approach to the diagnosis of the injured patient. 22 references.

  12. Reduction procedures for accurate analysis of MSX surveillance experiment data

    NASA Technical Reports Server (NTRS)

    Gaposchkin, E. Mike; Lane, Mark T.; Abbot, Rick I.

    1994-01-01

    Technical challenges of the Midcourse Space Experiment (MSX) science instruments require careful characterization and calibration of these sensors for analysis of surveillance experiment data. Procedures for reduction of Resident Space Object (RSO) detections will be presented which include refinement and calibration of the metric and radiometric (and photometric) data and calculation of a precise MSX ephemeris. Examples will be given which support the reduction, and these are taken from ground-test data similar in characteristics to the MSX sensors and from the IRAS satellite RSO detections. Examples to demonstrate the calculation of a precise ephemeris will be provided from satellites in similar orbits which are equipped with S-band transponders.

  13. Knowledge of accurate blood pressure measurement procedures in chiropractic students

    PubMed Central

    Crosley, Angela M.; Rose, James R. La

    2013-01-01

    Objective Blood pressure measurement is a basic clinical procedure. However, studies have shown that many errors are made when health care providers acquire blood pressure readings. Our study assessed knowledge of blood pressure measurement procedures in chiropractic students. Methods This was an observational, descriptive study. A questionnaire based on one created by the American Heart Association was given to 1st, 2nd, 3rd, and final year students (n = 186). A one way ANOVA was used to analyze the data. Results Of the students 80% were confident that their knowledge of this clinical skill was adequate or better. However, the overall score on the knowledge test of blood pressure–taking skills was 52% (range, 24%–88%). The only significant difference in the mean scores was between the 1st and 2nd year students compared to the 3rd and 4th year students (p < .005). Of the 16 questions given, the following mean scores were: 1st year 10.45, 2nd year 9.75, 3rd year 7.93, and 4th year 8.33. Of the 16 areas tested, 10 were of major concern (test item score <70%), showing the need for frequent retraining of chiropractic students. Conclusion Consistent with studies in other health care disciplines, our research found the knowledge of blood pressure skills to be deficient in our sample. There is a need for subsequent training in our teaching program. PMID:23957320

  14. Developments in the diagnostic procedures for von Willebrand disease.

    PubMed

    De Jong, A; Eikenboom, J

    2016-03-01

    Von Willebrand disease (VWD) is the most common inherited bleeding disorder but its diagnosis can be challenging due to the heterogeneity of the disease. VWD is mainly associated with mild mucocutaneous bleeding, although there are more severe phenotypes with bleeding from the gastrointestinal tract or even the joints. Also, surgical interventions and trauma may lead to critical bleeding events. These bleeding episodes are all related to quantitative or qualitative defects of von Willebrand factor (VWF), a multimeric glycoprotein produced by endothelial cells and megakaryocytes, which mediates platelet adhesion and aggregation and binds factor VIII (FVIII) in the circulation. This review describes the diagnostic procedures required for correct diagnosis. Accurate diagnosis and classification is required for proper treatment and counseling. Assessment of bleeding starts with the medical history. After a positive bleeding or family history, subsequent laboratory investigations will start with a panel of standard screening tests for hemostatic defects. Patients suspected of having VWD will be tested for plasma VWF antigen levels, the ability of VWF to bind platelets and FVIII activity. When VWD is confirmed, a set of subtyping tests can classify the patients as VWD types 1, 2 (A, B, M or N) or 3. The performance of some additional assays and analyses, such as VWF propeptide measurement or genetic analysis, may help in identifying the pathological mechanism behind certain defects or can guide in the choice of treatment.

  15. Cardiovascular procedures/diagnostic techniques and therapeutic procedures

    SciTech Connect

    Tilkian, A.G.; Daily, E.K.

    1986-01-01

    This book covers the technical and therapeutic aspects of cardiovascular procedures in immense detail. There are large and appropriate diagrams and tables. The topics of the chapters are tools for catheterization, venous access, arterial access, hemodynamic monitoring, cardiac catheterization and coronary arteriography, ergonovine provocation testing for coronary artery spasm, pulmonary angiography, endomyocredial biopsy, electrophysiologic studies, pericardiocentesis and drainage, intraaortic balloon pumping, direct current cardioversion and defibrilaltion, pacemaker implantation of the automatic implantable cardioverter/defibrillator, coronary angioplasty, thrombolytic therapy, transluminal catheter extraction and resolution of intracardiac catheter knots, cardiopulmonary resuscitation, contrast media toxicity and allergic reactions, radiation hazards, and medicolegal concerns. An appendix and index follow these chapters. In general, each chapter covers historical aspects, indications, complications, techniques, and preoperative and postoperative care.

  16. [Fetus radiation doses from nuclear medicine and radiology diagnostic procedures. Potential risks and radiation protection instructions].

    PubMed

    Markou, Pavlos

    2007-01-01

    Although in pregnancy it is strongly recommended to avoid diagnostic nuclear medicine and radiology procedures, in cases of clinical necessity or when pregnancy is not known to the physician, these diagnostic procedures are to be applied. In such cases, counseling based on accurate information and comprehensive discussion about the risks of radiation exposure to the fetus should follow. In this article, estimations of the absorbed radiation doses due to nuclear medicine and radiology diagnostic procedures during the pregnancy and their possible risk effects to the fetus are examined and then discussed. Stochastic and detrimental effects are evaluated with respect to other risk factors and related to the fetus absorbed radiation dose and to the post-conception age. The possible termination of a pregnancy, due to radiation exposure is discussed. Special radiation protection instructions are given for radiation exposures in cases of possible, confirmed or unknown pregnancies. It is concluded that nuclear medicine and radiology diagnostic procedures, if not repeated during the pregnancy, are rarely an indication for the termination of pregnancy, because the dose received by the fetus is expected to be less than 100 mSv, which indicates the threshold dose for having deterministic effects. Therefore, the risk for the fetus due to these diagnostic procedures is low. However, stochastic effects are still possible but will be minimized if the radiation absorbed dose to the fetus is kept as low as possible.

  17. Diagnostic procedures for submucosal tumors in the gastrointestinal tract

    PubMed Central

    Ponsaing, Laura Graves; Kiss, Katalin; Loft, Annika; Jensen, Lise Ingemann; Hansen, Mark Berner

    2007-01-01

    This review is part one of three, which will present an update on diagnostic procedures for gastrointestinal (GI) submucosal tumors (SMTs). Part two identifies the classification and part three the therapeutic methods regarding GI SMTs. Submucosal tumors are typically asymptomatic and therefore encountered incidentally. Advances in diagnostic tools for gastrointestinal submucosal tumors have emerged over the past decade. The aim of this paper is to provide the readers with guidelines for the use of diagnostic procedures, when a submucosal tumor is suspected. Literature searches were performed to find information on diagnostics for gastrointestinal submucosal tumors. Based on the searches, the optimal diagnostic procedures and specific features of the submucosal tumors could be outlined. Standard endoscppy, capsule endoscopy and push-and-pull enteroscopy (PPE) together with barium contrast X-ray do not alone provide sufficient information, when examining submucosal tumors. Endoscopic ultrasound (EUS), computed tomography (CT), magnetic resonance imaging (MRI) and fluorodeoxyglucose-labeled positron emission tomography (FDG-PET) are recommended as supplementary tools. PMID:17659668

  18. 40 CFR 85.2222 - Onboard diagnostic test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Tests § 85.2222 Onboard diagnostic test procedures. The test sequence for the OBD inspection shall consist of the following steps: (a) The OBD inspection shall be conducted with the key-on/engine running... Mode $01, PID $01 request in accordance with 40 CFR 86.1806 to determine the OBD evaluation status....

  19. Diagnostic Procedures for Detecting Nonlinear Relationships between Latent Variables

    ERIC Educational Resources Information Center

    Bauer, Daniel J.; Baldasaro, Ruth E.; Gottfredson, Nisha C.

    2012-01-01

    Structural equation models are commonly used to estimate relationships between latent variables. Almost universally, the fitted models specify that these relationships are linear in form. This assumption is rarely checked empirically, largely for lack of appropriate diagnostic techniques. This article presents and evaluates two procedures that can…

  20. Ventilation of neck breathers undergoing a diagnostic procedure or surgery.

    PubMed

    Brook, Itzhak

    2012-06-01

    Receiving sedation while undergoing a diagnostic procedure or general anesthesia for surgery is challenging for neck breathers including laryngectomees. Unfortunately, most medical personnel including nurses, medical technicians, surgeons, and anesthesiologists caring for laryngectomees before, during, and after surgery are not familiar with their unique anatomy, how they speak, and how to manage their airways during and after the operation. Methods to improve the care are discussed. Educating medical personnel about these issues can improve the care of neck breathers.

  1. Toward an accurate and efficient semiclassical surface hopping procedure for nonadiabatic problems.

    PubMed

    Herman, Michael F

    2005-10-20

    The derivation of a semiclassical surface hopping procedure from a formally exact solution of the Schrodinger equation is discussed. The fact that the derivation proceeds from an exact solution guarantees that all phase terms are completely and accurately included. Numerical evidence shows the method to be highly accurate. A Monte Carlo implementation of this method is considered, and recent work to significantly improve the statistical accuracy of the Monte Carlo approach is discussed.

  2. Enzyme immunoassays and related procedures in diagnostic medical virology

    PubMed Central

    Kurstak, Edouard; Tijssen, Peter; Kurstak, Christine; Morisset, Richard

    1986-01-01

    This review article describes several applications of the widely used enzyme immunoassay (EIA) procedure. EIA methods have been adapted to solve problems in diagnostic virology where sensitivity, specificity, or practicability is required. Concurrent developments in hybridoma and conjugation methods have increased significantly the use of these assays. A general overview of EIA methods is given together with typical examples of their use in diagnostic medical virology; attention is drawn to possible pitfalls. Recent advances in recombinant DNA technology have made it possible to produce highly specific nucleic acid probes that have a sensitivity approximately 100 times greater than that of EIA. Some applications of these probes are described. Although the non-labelled nucleic acid probes for use in the field are not as refined as non-labelled immunoassays, their range of applications is expected to expand rapidly in the near future. ImagesFig. 4 PMID:3533302

  3. Diagnostic methodology is critical for accurately determining the prevalence of ichthyophonus infections in wild fish populations

    USGS Publications Warehouse

    Kocan, R.; Dolan, H.; Hershberger, P.

    2011-01-01

    Several different techniques have been employed to detect and identify Ichthyophonus spp. in infected fish hosts; these include macroscopic observation, microscopic examination of tissue squashes, histological evaluation, in vitro culture, and molecular techniques. Examination of the peer-reviewed literature revealed that when more than 1 diagnostic method is used, they often result in significantly different results; for example, when in vitro culture was used to identify infected trout in an experimentally exposed population, 98.7% of infected trout were detected, but when standard histology was used to confirm known infected tissues from wild salmon, it detected ~50% of low-intensity infections and ~85% of high-intensity infections. Other studies on different species reported similar differences. When we examined a possible mechanism to explain the disparity between different diagnostic techniques, we observed non-random distribution of the parasite in 3-dimensionally visualized tissue sections from infected hosts, thus providing a possible explanation for the different sensitivities of commonly used diagnostic techniques. Based on experimental evidence and a review of the peer-reviewed literature, we have concluded that in vitro culture is currently the most accurate diagnostic technique for determining infection prevalence of Ichthyophonus, particularly when the exposure history of the population is not known.

  4. Using Copula Distributions to Support More Accurate Imaging-Based Diagnostic Classifiers for Neuropsychiatric Disorders

    PubMed Central

    Bansal, Ravi; Hao, Xuejun; Liu, Jun; Peterson, Bradley S.

    2014-01-01

    Many investigators have tried to apply machine learning techniques to magnetic resonance images (MRIs) of the brain in order to diagnose neuropsychiatric disorders. Usually the number of brain imaging measures (such as measures of cortical thickness and measures of local surface morphology) derived from the MRIs (i.e., their dimensionality) has been large (e.g. >10) relative to the number of participants who provide the MRI data (<100). Sparse data in a high dimensional space increases the variability of the classification rules that machine learning algorithms generate, thereby limiting the validity, reproducibility, and generalizability of those classifiers. The accuracy and stability of the classifiers can improve significantly if the multivariate distributions of the imaging measures can be estimated accurately. To accurately estimate the multivariate distributions using sparse data, we propose to estimate first the univariate distributions of imaging data and then combine them using a Copula to generate more accurate estimates of their multivariate distributions. We then sample the estimated Copula distributions to generate dense sets of imaging measures and use those measures to train classifiers. We hypothesize that the dense sets of brain imaging measures will generate classifiers that are stable to variations in brain imaging measures, thereby improving the reproducibility, validity, and generalizability of diagnostic classification algorithms in imaging datasets from clinical populations. In our experiments, we used both computer-generated and real-world brain imaging datasets to assess the accuracy of multivariate Copula distributions in estimating the corresponding multivariate distributions of real-world imaging data. Our experiments showed that diagnostic classifiers generated using imaging measures sampled from the Copula were significantly more accurate and more reproducible than were the classifiers generated using either the real-world imaging

  5. Diagnostic yield of blood clot culture in the accurate diagnosis of enteric fever and human brucellosis.

    PubMed

    Mantur, Basappa G; Bidari, Laxman H; Akki, Aravind S; Mulimani, Mallanna S; Tikare, Nitin V

    2007-01-01

    Culture of blood is the most frequent, accurate means of diagnosing bacteremia in enteric fever and brucellosis. However, conventional blood culturing is slow in isolating bacteria causing these diseases. In this work, we evaluated the performance of blood clot culture and conventional whole blood cultures in the accurate diagnosis of enteric fever (253 cases) and human brucellosis (71cases). The blood clot culture was found to be much more sensitive for both Salmonella (more by 34.4%, P< 0.001) and Brucella (more by 22.6%, P<0.001) than whole blood culture. Bacterial growth was significantly faster in cultures of blood clot compared to whole blood (1.1 versus 2.6 days for Salmonella, 3.1 versus 8.2 days for Brucella melitensis, respectively). The rapid confirmation of the etiological agent would facilitate an early institution of appropriate antimicrobial therapy, thereby reducing clinical morbidity especially in an endemic population. It is worthwile practicing blood clot culture for the accurate diagnosis of enteric fever and brucellosis in developing countries where diagnostic facilities by advanced technologies like automated culture systems and PCR are not available.

  6. Neonatal Cholestasis – Differential Diagnoses, Current Diagnostic Procedures, and Treatment

    PubMed Central

    Götze, Thomas; Blessing, Holger; Grillhösl, Christian; Gerner, Patrick; Hoerning, André

    2015-01-01

    Cholestatic jaundice in early infancy is a complex diagnostic problem. Misdiagnosis of cholestasis as physiologic jaundice delays the identification of severe liver diseases. In the majority of infants, prolonged physiologic jaundice represent benign cases of breast milk jaundice, but few among them are masked and caused by neonatal cholestasis (NC) that requires a prompt diagnosis and treatment. Therefore, a prolonged neonatal jaundice, longer than 2 weeks after birth, must always be investigated because an early diagnosis is essential for appropriate management. To rapidly identify the cases with cholestatic jaundice, the conjugated bilirubin needs to be determined in any infant presenting with prolonged jaundice at 14 days of age with or without depigmented stool. Once NC is confirmed, a systematic approach is the key to reliably achieve the diagnosis in order to promptly initiate the specific, and in many cases, life-saving therapy. This strategy is most important to promptly identify and treat infants with biliary atresia, the most common cause of NC, as this requires a hepatoportoenterostomy as soon as possible. Here, we provide a detailed work-up approach including initial treatment recommendations and a clinically oriented overview of possible differential diagnoses in order to facilitate the early recognition and a timely diagnosis of cholestasis. This approach warrants a broad spectrum of diagnostic procedures and investigations including new methods that are described in this review. PMID:26137452

  7. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  8. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  9. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  10. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  11. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  12. Activity based costing of diagnostic procedures at a nuclear medicine center of a tertiary care hospital

    PubMed Central

    Hada, Mahesh Singh; Chakravarty, Abhijit; Mukherjee, Partha

    2014-01-01

    Context: Escalating health care expenses pose a new challenge to the health care environment of becoming more cost-effective. There is an urgent need for more accurate data on the costs of health care procedures. Demographic changes, changing morbidity profile, and the rising impact of noncommunicable diseases are emphasizing the role of nuclear medicine (NM) in the future health care environment. However, the impact of emerging disease load and stagnant resource availability needs to be balanced by a strategic drive towards optimal utilization of available healthcare resources. Aim: The aim was to ascertain the cost of diagnostic procedures conducted at the NM Department of a tertiary health care facility by employing activity based costing (ABC) method. Materials and Methods: A descriptive cross-sectional study was carried out over a period of 1 year. ABC methodology was utilized for ascertaining unit cost of different diagnostic procedures and such costs were compared with prevalent market rates for estimating cost effectiveness of the department being studied. Results: The cost per unit procedure for various procedures varied from Rs. 869 (USD 14.48) for a thyroid scan to Rs. 11230 (USD 187.16) for a meta-iodo-benzyl-guanidine (MIBG) scan, the most cost-effective investigations being the stress thallium, technetium-99 m myocardial perfusion imaging (MPI) and MIBG scan. The costs obtained from this study were observed to be competitive when compared to prevalent market rates. Conclusion: ABC methodology provides precise costing inputs and should be used for all future costing studies in NM Departments. PMID:25400363

  13. 78 FR 20103 - Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... AGENCY Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures AGENCY..., on Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures. This document is Federal Guidance Report No. 14. It replaces Federal Guidance Report No. 9, ``Radiation Protection...

  14. Diagnostic Models for Procedural Bugs in Basic Mathematics Skills.

    ERIC Educational Resources Information Center

    Brown, John Seely; Burton, Richard R.

    A new diagnostic modeling system for automatically synthesizing a deep structure model of a student's misconceptions or bugs in his/her basic mathematics skills provides a mechanism for explaining why a student is making a mistake as opposed to simply identifying the mistake. This report consists of four sections. The first provides examples of…

  15. Refining Diagnostic Procedures for Adults With Symptoms of ADHD.

    PubMed

    Sibley, Margaret H; Coxe, Stefany; Molina, Brooke S G

    2017-04-01

    Attention deficit/hyperactivity disorder (ADHD) is a chronic disorder that afflicts individuals into adulthood. The field continues to refine diagnostic standards for ADHD in adults, complicated by the disorder's heterogeneous presentation, subjective symptoms, and overlap with other disorders. Two key diagnostic questions are from whom to collect diagnostic information and which symptoms should be contained on an adult diagnostic checklist. Using a trifactor model, Martel et al. examine these questions in a sample of adults with and without self-identified ADHD symptoms. In this response, we highlight the importance of their finding that self and informant symptom reports differ in a sample of adults who acknowledge ADHD symptoms. We also review issues that continue to face the field related to model specification, evaluating symptom utility, and sample composition, discussing how these issues influence conclusions that may be drawn from Martel et al. and similar investigations. We conclude that the article makes an important research contribution about the nature of self and informant ADHD symptom reports but emphasize that symptom checklist refinement must occur through a broad lens that considers work from a range of sample types and clinically informative analytic strategies.

  16. Model-Based Assurance of Diagnostic Procedures for Complex Systems

    DTIC Science & Technology

    2010-10-01

    this knowledge for fault detection and isolation . In parallel developments, different communities have found value in analytic state-based models...that are used for fault detection and isolation . Figure 2. The schematic of the Electrical Power System (EPS) in the Advanced Diagnostics and

  17. Hypnosis before diagnostic or therapeutic medical procedures: a systematic review.

    PubMed

    Cheseaux, Nicole; de Saint Lager, Alix Juillet; Walder, Bernhard

    2014-01-01

    The aim of this systematic review was to estimate the efficiency of hypnosis prior to medical procedures. Different databases were analyzed to identify randomized controlled trials (RCTs) comparing hypnosis to control interventions. All RCTs had to report pain or anxiety. Eighteen RCTs with a total of 968 patients were included; study size was from 20 to 200 patients (14 RCTs ≤ 60 patients). Fourteen RCTs included 830 adults and 4 RCTs included 138 children. Twelve of 18 RCTs had major quality limitations related to unclear allocation concealments, provider's experience in hypnosis, patient's adherence to hypnotic procedures, and intention-to-treat design. This systematic review observed major methodological limitations in RCTs on hypnosis prior to medical procedures.

  18. Galactography: the diagnostic procedure of choice for nipple discharge

    SciTech Connect

    Tabar, L.; Dean, P.B.; Pentek, Z.

    1983-10-01

    Galactogrpahy was performed in 204 women with a nipple discharge and the secretion confirmed histopathologically. All 116 intraductal tumors (papilloma, papillomatosis, carcinoma), which were associated with a serous or bloody discharge, were detected preoperatively. A palpable mass had little diagnostic significance, and exfoliative cytology was positive in only 11% (2/18) of the patients with carcinoma. The authors recommend that all patients with a spontaneous bloody or serous discharge from a single lactiferous orifice undergo galactography in addition to physical, cytological, and mammographic examination. Intraductal injection of methylene blue dye will demonstrate the affected duct system to the surgeon and can often make surgery less radical or even unnecessary.

  19. Computer-Aided Performance Training for Diagnostic and Procedural Tasks.

    ERIC Educational Resources Information Center

    Rigney, Joseph W.; And Others

    Two computer programs for computer-assisted performance training were developed to give the students the opportunity for concentrated practice of troubleshooting and procedural tasks in naval electronics. In contrast to the usual approach taken in computer-assisted instruction (CAI), these programs simulate essential aspects of devices and tasks…

  20. Development of a Sampling Collection Device with Diagnostic Procedures.

    PubMed

    Cheng, Jhih-Yan; Feng, Mow-Jung; Wu, Chia-Chi; Wang, Jane; Chang, Ting-Chang; Cheng, Chao-Min

    2016-08-02

    Cervicovaginal fluid plays an important role in the detection of many female genital diseases, but the lack of suitable collection devices in the market severely challenges test success rate. Appropriate clinical sampling devices for cervicovaginal fluid collection would help physicians detect diseases and disease states more rapidly, efficiently, and accurately. The objective of this study was to develop a readily usable sampling collection device that would eliminate macromolecular interference and accurately provide specimens for further studies. This study was designed to develop an effective device to collect cervicovaginal fluid from women with symptoms of endometrial lesions, women appearing in the clinic for a routine Papanicolaou smear, and/or women seeking a routine gynecologic checkup. Paper-based assay, ELISA, and qNano were used to provide accurate diagnoses. A total of 103 patients successfully used the developed device to collect cervicovaginal fluid. Some of the collected specimens were used to detect glycogen, lactate, and pH for determining pathogen infection. Other specimen samples were tested for the presence of female genital cancer by comparing interleukin 6 concentration and microvesicle concentration. We proposed a noninvasive screening test for the diagnosis of female genital diseases using a dual-material collection device. The outer, nonwoven fabric portion of this device was designed to filter macromolecules, and the inner cotton portion was designed to absorb cervicovaginal fluid.

  1. Smartphone-Based Accurate Analysis of Retinal Vasculature towards Point-of-Care Diagnostics

    PubMed Central

    Xu, Xiayu; Ding, Wenxiang; Wang, Xuemin; Cao, Ruofan; Zhang, Maiye; Lv, Peilin; Xu, Feng

    2016-01-01

    Retinal vasculature analysis is important for the early diagnostics of various eye and systemic diseases, making it a potentially useful biomarker, especially for resource-limited regions and countries. Here we developed a smartphone-based retinal image analysis system for point-of-care diagnostics that is able to load a fundus image, segment retinal vessels, analyze individual vessel width, and store or uplink results. The proposed system was not only evaluated on widely used public databases and compared with the state-of-the-art methods, but also validated on clinical images directly acquired with a smartphone. An Android app is also developed to facilitate on-site application of the proposed methods. Both visual assessment and quantitative assessment showed that the proposed methods achieved comparable results to the state-of-the-art methods that require high-standard workstations. The proposed system holds great potential for the early diagnostics of various diseases, such as diabetic retinopathy, for resource-limited regions and countries. PMID:27698369

  2. Surprise, p-value, s-value and a diagnostic procedure to detect not informative experiments

    NASA Astrophysics Data System (ADS)

    Recchia, Daniela R.; Ostermann, Thomas; Garcia, Jesus E.

    2016-06-01

    In this paper, examples of diverse measures of significance are studied in the frame of Neyman-Pearson hypothesis tests. A diagnostic procedure is proposed, to detect non informative experiments where the p-value procedure might fail to measure the significance of the outcome of an experiment.

  3. [An aphasic man with high fever; difficulty with diagnostic procedure].

    PubMed

    Potjewijd, J; Buijs, J

    2008-07-12

    A 73-year-old man, with known motor aphasia presented with high fever, dyspnoea, and vomiting. Only after several days it appeared that these signs were due to a sepsis as a consequence of a phlegmon of the neck, caused by an aspired part of his set of false teeth. The delay before diagnosis was due to the fact that adequate medical history taking was difficult because of the aphasia and attempts at non-verbal communication were poorly understood. The localization of the corpus alienum was a second pitfall, because it could not be visualized during physical examination or on the initial chest X-ray. The increased risk of colonization of dentures with pathogenic micro-organisms in nursing home residents may have played a role in the severe course of this infection. This case illustrates the diagnostic problems that may exist in patients who are unable to communicate adequately.

  4. Overview of the impact of noninvasive prenatal testing on diagnostic procedures.

    PubMed

    Warsof, Steven L; Larion, Sebastian; Abuhamad, Alfred Z

    2015-10-01

    Noninvasive prenatal testing (NIPT) has had a profound influence in the field of prenatal diagnosis since the 1997 discovery of cell-free fetal DNA in maternal blood. Research has progressed rapidly, with clinical data supporting laboratory studies showing that NIPT is highly sensitive and specific for fetal aneuploidy, resulting in marked uptake in the high-risk patient population. The superior accuracy of NIPT compared with conventional screening methods has led to significant decreases in the number of invasive diagnostic procedures, in addition to a concomitant decrease in the number of procedure-related fetal losses. Yet, NIPT has been described as a 'disruptive innovation' due to the considerable changes the technology has commanded on current prenatal screening and diagnostic practices. This review summarizes both institutional and global experience with NIPT uptake, its effect on reducing diagnostic invasive procedures, and the unique challenges that reduced procedural volume may have on physician and trainee proficiency, cytogenetic laboratories, and neonatal outcome.

  5. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    PubMed Central

    Rogers, Linda C.; Scott, Laurie; Block, Jon E.

    2016-01-01

    OBJECTIVE Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. METHODS Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus®) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. RESULTS Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%), specificity (94.8% vs. 79.3%), PPV (75% vs. 36.8%), NPV (100% vs. 95.8%), and accuracy (95.5% vs. 79.1%). CONCLUSIONS The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity. PMID:27199579

  6. Optimizing odor identification testing as quick and accurate diagnostic tool for Parkinson's disease

    PubMed Central

    Mahlknecht, Philipp; Pechlaner, Raimund; Boesveldt, Sanne; Volc, Dieter; Pinter, Bernardette; Reiter, Eva; Müller, Christoph; Krismer, Florian; Berendse, Henk W.; van Hilten, Jacobus J.; Wuschitz, Albert; Schimetta, Wolfgang; Högl, Birgit; Djamshidian, Atbin; Nocker, Michael; Göbel, Georg; Gasperi, Arno; Kiechl, Stefan; Willeit, Johann; Poewe, Werner

    2016-01-01

    ABSTRACT Introduction The aim of this study was to evaluate odor identification testing as a quick, cheap, and reliable tool to identify PD. Methods Odor identification with the 16‐item Sniffin' Sticks test (SS‐16) was assessed in a total of 646 PD patients and 606 controls from three European centers (A, B, and C), as well as 75 patients with atypical parkinsonism or essential tremor and in a prospective cohort of 24 patients with idiopathic rapid eye movement sleep behavior disorder (center A). Reduced odor sets most discriminative for PD were determined in a discovery cohort derived from a random split of PD patients and controls from center A using L1‐regularized logistic regression. Diagnostic accuracy was assessed in the rest of the patients/controls as validation cohorts. Results Olfactory performance was lower in PD patients compared with controls and non‐PD patients in all cohorts (each P < 0.001). Both the full SS‐16 and a subscore of the top eight discriminating odors (SS‐8) were associated with an excellent discrimination of PD from controls (areas under the curve ≥0.90; sensitivities ≥83.3%; specificities ≥82.0%) and from non‐PD patients (areas under the curve ≥0.91; sensitivities ≥84.1%; specificities ≥84.0%) in all cohorts. This remained unchanged when patients with >3 years of disease duration were excluded from analysis. All 8 incident PD cases among patients with idiopathic rapid eye movement sleep behavior disorder were predicted with the SS‐16 and the SS‐8 (sensitivity, 100%; positive predictive value, 61.5%). Conclusions Odor identification testing provides excellent diagnostic accuracy in the distinction of PD patients from controls and diagnostic mimics. A reduced set of eight odors could be used as a quick tool in the workup of patients presenting with parkinsonism and for PD risk indication. © 2016 The Authors. Movement Disorders published by Wiley Periodicals, Inc. on behalf of International Parkinson and

  7. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  8. Diagnostic x-ray procedures and risk of leukemia, lymphoma, and multiple myeloma

    SciTech Connect

    Boice, J.D. Jr.; Morin, M.M.; Glass, A.G.; Friedman, G.D.; Stovall, M.; Hoover, R.N.; Fraumeni, J.F. Jr. )

    1991-03-13

    Exposure to diagnostic x-rays and the risk of leukemia, non-Hodgkin's lymphoma (NHL), and multiple myeloma were studied within two prepaid health plans. Adult patients with leukemia (n = 565), NHL (n = 318), and multiple myeloma (n = 208) were matched to controls (n = 1390), and over 25,000 x-ray procedures were abstracted from medical records. Dose response was evaluated by assigning each x-ray procedure a score based on estimated bone marrow dose. X-ray exposure was not associated with chronic lymphocytic leukemia, one of the few malignant conditions never linked to radiation (relative risk (RR), 0.66). For all other forms of leukemia combined (n = 358), there was a slight elevation in risk (RR, 1.17) but no evidence of a dose-response relationship when x-ray procedures near the time of diagnosis were excluded. Similarly, patients with NHL were exposed to diagnostic x-ray procedures more often than controls (RR, 1.32), but the RR fell to 0.99 when the exposure to diagnostic x-ray procedures within 2 years of diagnosis was ignored. For multiple myeloma, overall risk was not significantly high (RR, 1.14), but there was consistent evidence of increasing risk with increasing numbers of diagnostic x-ray procedures. These data suggest that persons with leukemia and NHL undergo x-ray procedures frequently just prior to diagnosis for conditions related to the development or natural history of their disease. There was little evidence that diagnostic x-ray procedures were causally associated with leukemia or NHL. The risk for multiple myeloma, however, was increased among those patients who were frequently exposed to x-rays.

  9. RT-PCR is a more accurate diagnostic tool for detection of BCR-ABL rearrangement

    SciTech Connect

    Zehnbauer, B.A.; Allen, A.P.; McGrath, S.D.

    1994-09-01

    Detection of the Philadelphia chromosome (Ph1) or genomic Southern hybridization for clonal gene rearrangement (GSH-R) has provided very specific identification of BCR-ABL gene rearrangement. Reverse transcriptase-polymerase chain reaction (RT-PCR) is diagnostic for patterns of BCR-ABL expression which are undetected by GSH-R and/or Ph1 and provides increased sensitivity both at diagnosis and in detection of minimal residual leukemia. Fifty-three specimens (of 150 tested from 119 consecutive leukemia patients) were RT-PCR positive for BCR-ABL gene expression confirmed by hybridization of PCR products with b{sub 3}a{sub 2}, b{sub 2}a{sub 2}, or e{sub 1}a{sub 2} junction-specific oligonucleotides. In 6 cases of CML with GSH-R{sup {minus}}at diagnosis, RT-PCR provided specific BCR-ABL identification. Deletion of BCR regions, low mitotic index, or e{sub 1}a{sub 2} expression caused failure to detect GSH-R or Ph1 translocation.

  10. Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation

    PubMed Central

    Dingari, Narahara Chari; Horowitz, Gary L.; Kang, Jeon Woong; Dasari, Ramachandra R.; Barman, Ishan

    2012-01-01

    We present the first demonstration of glycated albumin detection and quantification using Raman spectroscopy without the addition of reagents. Glycated albumin is an important marker for monitoring the long-term glycemic history of diabetics, especially as its concentrations, in contrast to glycated hemoglobin levels, are unaffected by changes in erythrocyte life times. Clinically, glycated albumin concentrations show a strong correlation with the development of serious diabetes complications including nephropathy and retinopathy. In this article, we propose and evaluate the efficacy of Raman spectroscopy for determination of this important analyte. By utilizing the pre-concentration obtained through drop-coating deposition, we show that glycation of albumin leads to subtle, but consistent, changes in vibrational features, which with the help of multivariate classification techniques can be used to discriminate glycated albumin from the unglycated variant with 100% accuracy. Moreover, we demonstrate that the calibration model developed on the glycated albumin spectral dataset shows high predictive power, even at substantially lower concentrations than those typically encountered in clinical practice. In fact, the limit of detection for glycated albumin measurements is calculated to be approximately four times lower than its minimum physiological concentration. Importantly, in relation to the existing detection methods for glycated albumin, the proposed method is also completely reagent-free, requires barely any sample preparation and has the potential for simultaneous determination of glycated hemoglobin levels as well. Given these key advantages, we believe that the proposed approach can provide a uniquely powerful tool for quantification of glycation status of proteins in biopharmaceutical development as well as for glycemic marker determination in routine clinical diagnostics in the future. PMID:22393405

  11. Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study

    PubMed Central

    Ihn, Yon Kwon; Byun, Jun Soo; Suh, Sang Hyun; Won, Yoo Dong; Lee, Deok Hee; Kim, Byung Moon; Kim, Young Soo; Jeon, Pyong; Ryu, Chang-Woo; Suh, Sang-il; Choi, Dae Seob; Choi, See Sung; Choi, Jin Wook; Chang, Hyuk Won; Lee, Jae-Wook; Kim, Sang Heum; Lee, Young Jun; Shin, Shang Hun; Lim, Soo Mee; Yoon, Woong; Jeong, Hae Woong; Han, Moon Hee

    2016-01-01

    Purpose To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). Materials and Methods We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. Results Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm2, 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm2, 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm2 for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm2 for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. Conclusion Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures. PMID:27621943

  12. An Example of the Application of the Assessment and Diagnostic Procedures of a Comprehensive Accountability Plan.

    ERIC Educational Resources Information Center

    Marco, Gary L.

    The assessment and diagnostic procedures of a comprehensive accountability plan were applied to several elementary schools from a large midwestern state. Pretest and posttest Word Knowledge and Reading scores from the Primary II Metropolitan Achievement Test administered in 1970-71 to third-graders were used. These data were used to compute…

  13. PROCEDURES FOR ACCURATE PRODUCTION OF COLOR IMAGES FROM SATELLITE OR AIRCRAFT MULTISPECTRAL DIGITAL DATA.

    USGS Publications Warehouse

    Duval, Joseph S.

    1985-01-01

    Because the display and interpretation of satellite and aircraft remote-sensing data make extensive use of color film products, accurate reproduction of the color images is important. To achieve accurate color reproduction, the exposure and chemical processing of the film must be monitored and controlled. By using a combination of sensitometry, densitometry, and transfer functions that control film response curves, all of the different steps in the making of film images can be monitored and controlled. Because a sensitometer produces a calibrated exposure, the resulting step wedge can be used to monitor the chemical processing of the film. Step wedges put on film by image recording machines provide a means of monitoring the film exposure and color balance of the machines.

  14. Use and abuse of eight widely-used diagnostic procedures in clinical immunology: a WHO Memorandum*

    PubMed Central

    1981-01-01

    This Memorandum assesses eight widely-used diagnostic procedures with the aim of establishing their usefulness in patient care. For each procedure, the main methods that can be recommended at present are outlined and their pitfalls discussed. For each procedure, recommendations are made as to the clinical conditions for which the test is essential for diagnosis, the conditions for which the test will help in assessing and monitoring disease activity, and the conditions for which the test is useful for research purposes only. PMID:7032736

  15. Accurate, fast and cost-effective diagnostic test for monosomy 1p36 using real-time quantitative PCR.

    PubMed

    Cunha, Pricila da Silva; Pena, Heloisa B; D'Angelo, Carla Sustek; Koiffmann, Celia P; Rosenfeld, Jill A; Shaffer, Lisa G; Stofanko, Martin; Gonçalves-Dornelas, Higgor; Pena, Sérgio Danilo Junho

    2014-01-01

    Monosomy 1p36 is considered the most common subtelomeric deletion syndrome in humans and it accounts for 0.5-0.7% of all the cases of idiopathic intellectual disability. The molecular diagnosis is often made by microarray-based comparative genomic hybridization (aCGH), which has the drawback of being a high-cost technique. However, patients with classic monosomy 1p36 share some typical clinical characteristics that, together with its common prevalence, justify the development of a less expensive, targeted diagnostic method. In this study, we developed a simple, rapid, and inexpensive real-time quantitative PCR (qPCR) assay for targeted diagnosis of monosomy 1p36, easily accessible for low-budget laboratories in developing countries. For this, we have chosen two target genes which are deleted in the majority of patients with monosomy 1p36: PRKCZ and SKI. In total, 39 patients previously diagnosed with monosomy 1p36 by aCGH, fluorescent in situ hybridization (FISH), and/or multiplex ligation-dependent probe amplification (MLPA) all tested positive on our qPCR assay. By simultaneously using these two genes we have been able to detect 1p36 deletions with 100% sensitivity and 100% specificity. We conclude that qPCR of PRKCZ and SKI is a fast and accurate diagnostic test for monosomy 1p36, costing less than 10 US dollars in reagent costs.

  16. Evaluation of a pan-serotype point-of-care rapid diagnostic assay for accurate detection of acute dengue infection.

    PubMed

    Vivek, Rosario; Ahamed, Syed Fazil; Kotabagi, Shalini; Chandele, Anmol; Khanna, Ira; Khanna, Navin; Nayak, Kaustuv; Dias, Mary; Kaja, Murali-Krishna; Shet, Anita

    2017-03-01

    The catastrophic rise in dengue infections in India and globally has created a need for an accurate, validated low-cost rapid diagnostic test (RDT) for dengue. We prospectively evaluated the diagnostic performance of NS1/IgM RDT (dengue day 1) using 211 samples from a pediatric dengue cohort representing all 4 serotypes in southern India. The dengue-positive panel consisted of 179 dengue real-time polymerase chain reaction (RT-PCR) positive samples from symptomatic children. The dengue-negative panel consisted of 32 samples from dengue-negative febrile children and asymptomatic individuals that were negative for dengue RT-PCR/NS1 enzyme-linked immunosorbent assay/IgM/IgG. NS1/IgM RDT sensitivity was 89.4% and specificity was 93.8%. The NS1/IgM RDT showed high sensitivity throughout the acute phase of illness, in primary and secondary infections, in different severity groups, and detected all 4 dengue serotypes, including coinfections. This NS1/IgM RDT is a useful point-of-care assay for rapid and reliable diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  17. Accurate, Fast and Cost-Effective Diagnostic Test for Monosomy 1p36 Using Real-Time Quantitative PCR

    PubMed Central

    Cunha, Pricila da Silva; Pena, Heloisa B.; D'Angelo, Carla Sustek; Koiffmann, Celia P.; Rosenfeld, Jill A.; Shaffer, Lisa G.; Stofanko, Martin; Gonçalves-Dornelas, Higgor; Pena, Sérgio Danilo Junho

    2014-01-01

    Monosomy 1p36 is considered the most common subtelomeric deletion syndrome in humans and it accounts for 0.5–0.7% of all the cases of idiopathic intellectual disability. The molecular diagnosis is often made by microarray-based comparative genomic hybridization (aCGH), which has the drawback of being a high-cost technique. However, patients with classic monosomy 1p36 share some typical clinical characteristics that, together with its common prevalence, justify the development of a less expensive, targeted diagnostic method. In this study, we developed a simple, rapid, and inexpensive real-time quantitative PCR (qPCR) assay for targeted diagnosis of monosomy 1p36, easily accessible for low-budget laboratories in developing countries. For this, we have chosen two target genes which are deleted in the majority of patients with monosomy 1p36: PRKCZ and SKI. In total, 39 patients previously diagnosed with monosomy 1p36 by aCGH, fluorescent in situ hybridization (FISH), and/or multiplex ligation-dependent probe amplification (MLPA) all tested positive on our qPCR assay. By simultaneously using these two genes we have been able to detect 1p36 deletions with 100% sensitivity and 100% specificity. We conclude that qPCR of PRKCZ and SKI is a fast and accurate diagnostic test for monosomy 1p36, costing less than 10 US dollars in reagent costs. PMID:24839341

  18. A Machine-Independent ALGOL Procedure for Accurate Floating-Point Summation

    DTIC Science & Technology

    The paper describes all ALGOL 60 procedure which is an implementation of the floating - point summation technique described in Malcolm (1971). This...implementation is machine-independent in the sense that it will work on nay computer having a floating - point number system F characterized as follows...number 0 is contained in F , but no assumption is made about its representation. All floating - point operations (e.g., addition and multiplication) are

  19. An Overview of Models of Speaking Performance and Its Implications for the Development of Procedural Framework for Diagnostic Speaking Tests

    ERIC Educational Resources Information Center

    Zhao, Zhongbao

    2013-01-01

    This paper aims at developing a procedural framework for the development and validation of diagnostic speaking tests. The researcher reviews the current available models of speaking performance, analyzes the distinctive features and then points out the implications for the development of a procedural framework for diagnostic speaking tests. On…

  20. A Procedure for Accurately Measuring the Shaker Overturning Moment During Random Vibration Tests

    NASA Technical Reports Server (NTRS)

    Nayeri, Reza D.

    2011-01-01

    Motivation: For large system level random vibration tests, there may be some concerns about the shaker's capability for the overturning moment. It is the test conductor's responsibility to predict and monitor the overturning moment during random vibration tests. If the predicted moment is close to the shaker's capability, test conductor must measure the instantaneous moment at low levels and extrapolate to higher levels. That data will be used to decide whether it is safe to proceed to the next test level. Challenge: Kistler analog formulation for computing the real-time moment is only applicable to very limited cases in which we have 3 or 4 load cells installed at shaker interface with hardware. Approach: To overcome that limitation, a simple procedure was developed for computing the overturning moment time histories using the measured time histories of the individual load cells.

  1. A Three Dimensional Parallel Time Accurate Turbopump Simulation Procedure Using Overset Grid Systems

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin; Chan, William; Kwak, Dochan

    2001-01-01

    The objective of the current effort is to provide a computational framework for design and analysis of the entire fuel supply system of a liquid rocket engine, including high-fidelity unsteady turbopump flow analysis. This capability is needed to support the design of pump sub-systems for advanced space transportation vehicles that are likely to involve liquid propulsion systems. To date, computational tools for design/analysis of turbopump flows are based on relatively lower fidelity methods. An unsteady, three-dimensional viscous flow analysis tool involving stationary and rotational components for the entire turbopump assembly has not been available for real-world engineering applications. The present effort provides developers with information such as transient flow phenomena at start up, and non-uniform inflows, and will eventually impact on system vibration and structures. In the proposed paper, the progress toward the capability of complete simulation of the turbo-pump for a liquid rocket engine is reported. The Space Shuttle Main Engine (SSME) turbo-pump is used as a test case for evaluation of the hybrid MPI/Open-MP and MLP versions of the INS3D code. CAD to solution auto-scripting capability is being developed for turbopump applications. The relative motion of the grid systems for the rotor-stator interaction was obtained using overset grid techniques. Unsteady computations for the SSME turbo-pump, which contains 114 zones with 34.5 million grid points, are carried out on Origin 3000 systems at NASA Ames Research Center. Results from these time-accurate simulations with moving boundary capability will be presented along with the performance of parallel versions of the code.

  2. A Three-Dimensional Parallel Time-Accurate Turbopump Simulation Procedure Using Overset Grid System

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin; Chan, William; Kwak, Dochan

    2002-01-01

    The objective of the current effort is to provide a computational framework for design and analysis of the entire fuel supply system of a liquid rocket engine, including high-fidelity unsteady turbopump flow analysis. This capability is needed to support the design of pump sub-systems for advanced space transportation vehicles that are likely to involve liquid propulsion systems. To date, computational tools for design/analysis of turbopump flows are based on relatively lower fidelity methods. An unsteady, three-dimensional viscous flow analysis tool involving stationary and rotational components for the entire turbopump assembly has not been available for real-world engineering applications. The present effort provides developers with information such as transient flow phenomena at start up, and nonuniform inflows, and will eventually impact on system vibration and structures. In the proposed paper, the progress toward the capability of complete simulation of the turbo-pump for a liquid rocket engine is reported. The Space Shuttle Main Engine (SSME) turbo-pump is used as a test case for evaluation of the hybrid MPI/Open-MP and MLP versions of the INS3D code. CAD to solution auto-scripting capability is being developed for turbopump applications. The relative motion of the grid systems for the rotor-stator interaction was obtained using overset grid techniques. Unsteady computations for the SSME turbo-pump, which contains 114 zones with 34.5 million grid points, are carried out on Origin 3000 systems at NASA Ames Research Center. Results from these time-accurate simulations with moving boundary capability are presented along with the performance of parallel versions of the code.

  3. PICVib: an accurate, fast and simple procedure to investigate selected vibrational modes and evaluate infrared intensities.

    PubMed

    dos Santos, Marcus V P; Proenza, Yaicel G; Longo, Ricardo L

    2014-09-07

    The generalization of the PICVib approach [M. V. P. dos Santos et al., J. Comput. Chem., 2013, 34, 611] for calculating infrared intensities is shown to be successful and to preserve all interesting features of the procedure such as easiness of implementation and parallelization, flexibility, treatment of large systems and at high theoretical levels. It was tested and validated for very diverse molecular systems: XH3 (D3h), YH4 (D4h), conformers of RDX, S(N)2 and E2 reaction product complexes, the [W(dppe)2(NNC5H10)] complex, carbon nanotubes, and hydrogen-bonded complexes (H2O···HOH, MeHO···HOH, MeOH···OH2, MeOH···OHMe) including the guanine-cytosine pair. The PICVib shows an excellent overall performance for calculating infrared intensities of localized normal modes and even mixed vibrations, whereas care must be taken for vibrations involving intermolecular interactions. DFT functionals are still the best combination with high level ab initio methods such as CCSD and CCSD(T).

  4. Activities identification for activity-based cost/management applications of the diagnostics outpatient procedures.

    PubMed

    Alrashdan, Abdalla; Momani, Amer; Ababneh, Tamador

    2012-01-01

    One of the most challenging problems facing healthcare providers is to determine the actual cost for their procedures, which is important for internal accounting and price justification to insurers. The objective of this paper is to find suitable categories to identify the diagnostic outpatient medical procedures and translate them from functional orientation to process orientation. A hierarchal task tree is developed based on a classification schema of procedural activities. Each procedure is seen as a process consisting of a number of activities. This makes a powerful foundation for activity-based cost/management implementation and provides enough information to discover the value-added and non-value-added activities that assist in process improvement and eventually may lead to cost reduction. Work measurement techniques are used to identify the standard time of each activity at the lowest level of the task tree. A real case study at a private hospital is presented to demonstrate the proposed methodology.

  5. Delaying diagnostic procedure significantly increases mortality in patients with invasive mucormycosis.

    PubMed

    Jeong, Su Jin; Lee, Ji Un; Song, Young Goo; Lee, Kyoung Hwa; Lee, Min Joo

    2015-12-01

    Invasive mucormycosis is an uncommon but increasing life-threatening fungal infection. The present study investigated clinical characteristics and mortality among patients diagnosed as invasive mucormycosis infection. We retrospectively reviewed a total of 24 histologically proven cases of invasive mucormycosis at two tertiary care referral hospitals between November 2005 and February 2014. Overall survival was 50% (n = 12). The time between onset of symptom and diagnostic procedure proved to be associated with mortality (P = 0.009). In addition, preexisting renal failure and thrombocytopenia demonstrated trends toward a poor outcome in our study (P = 0.089 and 0.065, respectively). On multivariate regression analysis, delayed diagnostic procedure (more than 16 days after the onset of symptoms) was an independent predictor of mortality (OR= 12.34, 95% CI, 1.43-10.64; P = 0.022). Mucormycosis is a destructive fungal infection that is associated with high mortality rates, ranging from 40% to 100% depending on the form of disease. When a clinician suspects invasive mucormycosis infection, an early diagnostic procedure performed within 16 days from the onset of symptom and early initiation of antifungal therapy will lead to successful management of this highly fatal disease.

  6. Broken rotor bars detection by a new non-invasive diagnostic procedure

    NASA Astrophysics Data System (ADS)

    Eltabach, Mario; Antoni, Jerome; Shanina, Galyna; Sieg-Zieba, Sophie; Carniel, Xavier

    2009-05-01

    A new technique of diagnosing data for broken rotor bars in induction motors derived from two of the three stator currents, the Beirut diagnostic procedure (BDP) is presented in this paper. The theoretical principles directly related to the application of this diagnostic technique are described, emphasizing the use of a severity factor in order to evaluate the extension of the fault. Defining the severity factor as the normalized amplitude of the fault characteristic frequency enables us to draw up a table of comparison of several usual electric diagnostic methods. Besides the traditional one-phase current spectrum analysis, values of the severity factor related to electrical signals like the instantaneous powers, the current space vector modulus and finally related to the new Beirut diagnostic method are analyzed with respect to the variation of the power factor angle and of the sum of the two current side-band angular displacement. The BDP offers several advantages over the usual motor current signature analyses (MCSA) methods: it is shown how the proposed severity factor applied to the new diagnostic technique is not dependent on motor parameters such as the power factor angle and the fault type which is not the case of the instantaneous powers. In addition, the BDP has the advantage of detecting easily fault characteristic frequencies, which is not possible via diagnostic methods that use the detection of two side-band components as in the simple current spectrum. By theoretical analysis, computer simulations, and laboratory experiments, it is shown that the new method enhances the reliability of diagnostics of broken rotor bars in induction motor.

  7. Risk and safety requirements for diagnostic and therapeutic procedures in allergology: World Allergy Organization Statement.

    PubMed

    Kowalski, Marek L; Ansotegui, Ignacio; Aberer, Werner; Al-Ahmad, Mona; Akdis, Mubeccel; Ballmer-Weber, Barbara K; Beyer, Kirsten; Blanca, Miguel; Brown, Simon; Bunnag, Chaweewan; Hulett, Arnaldo Capriles; Castells, Mariana; Chng, Hiok Hee; De Blay, Frederic; Ebisawa, Motohiro; Fineman, Stanley; Golden, David B K; Haahtela, Tari; Kaliner, Michael; Katelaris, Connie; Lee, Bee Wah; Makowska, Joanna; Muller, Ulrich; Mullol, Joaquim; Oppenheimer, John; Park, Hae-Sim; Parkerson, James; Passalacqua, Giovanni; Pawankar, Ruby; Renz, Harald; Rueff, Franziska; Sanchez-Borges, Mario; Sastre, Joaquin; Scadding, Glenis; Sicherer, Scott; Tantilipikorn, Pongsakorn; Tracy, James; van Kempen, Vera; Bohle, Barbara; Canonica, G Walter; Caraballo, Luis; Gomez, Maximiliano; Ito, Komei; Jensen-Jarolim, Erika; Larche, Mark; Melioli, Giovanni; Poulsen, Lars K; Valenta, Rudolf; Zuberbier, Torsten

    2016-01-01

    One of the major concerns in the practice of allergy is related to the safety of procedures for the diagnosis and treatment of allergic disease. Management (diagnosis and treatment) of hypersensitivity disorders involves often intentional exposure to potentially allergenic substances (during skin testing), deliberate induction in the office of allergic symptoms to offending compounds (provocation tests) or intentional application of potentially dangerous substances (allergy vaccine) to sensitized patients. These situations may be associated with a significant risk of unwanted, excessive or even dangerous reactions, which in many instances cannot be completely avoided. However, adverse reactions can be minimized or even avoided if a physician is fully aware of potential risk and is prepared to appropriately handle the situation. Information on the risk of diagnostic and therapeutic procedures in allergic diseases has been accumulated in the medical literature for decades; however, except for allergen specific immunotherapy, it has never been presented in a systematic fashion. Up to now no single document addressed the risk of the most commonly used medical procedures in the allergy office nor attempted to present general requirements necessary to assure the safety of these procedures. Following review of available literature a group of allergy experts within the World Allergy Organization (WAO), representing various continents and areas of allergy expertise, presents this report on risk associated with diagnostic and therapeutic procedures in allergology and proposes a consensus on safety requirements for performing procedures in allergy offices. Optimal safety measures including appropriate location, type and required time of supervision, availability of safety equipment, access to specialized emergency services, etc. for various procedures have been recommended. This document should be useful for allergists with already established practices and experience as well

  8. Comparison of two types of adult phantoms in terms of organ doses from diagnostic CT procedures

    NASA Astrophysics Data System (ADS)

    Liu, Haikuan; Gu, Jianwei; Caracappa, Peter F.; Xu, X. George

    2010-03-01

    The rapidly increasing number of diagnostic computed tomography (CT) procedures in the recent decades has spurred heightened concern over the potential risk to patients. Although an accurate organ dose assessment tool has now become highly desirable, existing software packages depend on stylized computational phantoms that were originally developed more than 40 years ago, exhibiting very large discrepancies when compared with phantoms that are anatomically realistic. However, past comparative studies did not focus on CT protocols for adult patients. This study was designed to quantitatively compare two types of phantoms, the stylized phantoms and a pair of recently developed RPI-adult male and adult female (RPI-AM and RPI-AF) phantoms, for various CT scanning protocols involving the chest, abdomen-pelvis and chest-abdomen-pelvis. Organ doses were based on Monte Carlo simulations using the MCNPX code and a detailed CT scanner model for the GE LightSpeed 16. Results are presented as ratios of organ doses from the stylized phantoms to those from the RPI phantoms. It is found that, for most organs contained in the scan volume, the ratios were within the range of 0.75-1.16. However, the stomach doses are significantly different and the ratio is found to be up to 1.86 in male phantoms and 2.29 in the female phantoms due to the anatomical differences between the two types of phantoms. Organs that lie near a scan boundary also exhibit a significant relative difference in organ doses between the two types of phantoms. This study concludes that, due to relatively low x-ray energies, CT doses are very sensitive to organ shape, size and position, and thus anatomically realistic phantoms should be used to avoid the dose uncertainties caused by the lack of anatomical realism. The new phantoms, such as the RPI-AM and AF phantoms that are designed using advanced surface meshes, are deformable and will make it possible to match the anatomy of a specific patient leading to further

  9. Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center

    PubMed Central

    Chun, Chang Woo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong-Sam

    2014-01-01

    Objective To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. Materials and Methods We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Results Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 ± 44.8 Gy-cm2, and 251 ± 49 frames for diagnostic procedures, 52.9 minutes, 226.0 ± 129.2 Gy-cm2, and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 ± 184.6 Gy-cm2, and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 ± 3.2 Gy-cm2. On average, rotational angiography was used 1.4 ± 0.6 times/session (range, 1-4; n = 580). Conclusion Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level. PMID:25469098

  10. Gene technology in medical diagnostics and criminal procedure and liability for malpractice in Germany.

    PubMed

    Deutsch, E; Füllmich, R; Poppe, H

    1990-01-01

    The increasing employment of gene technological procedures in medical diagnostics and criminal procedure has forced both the medical and the legal professions to focus their attention on the complex question of liability of physicians, lab technicians, and other personnel involved in applying these measures. This article gives an outline, by citing practical cases, of the major aspects of liability for malpractice that are relevant under German law. Bearing in mind that this article will be read predominantly by members of the Anglo-American common-law legal system, the legal aspects - even though they are German legal aspects - are viewed in the light of the common law. The article examines three major issues: (a) liability for diagnoses employing gene technological procedures: (b) liability for wrong testimony based on 'genetic finger-printing': and (c) the donor's rights concerning his or her DNA-probe.

  11. Triggering radiation alarm at security checks. Patients should be informed even after diagnostic nuclear medicine procedures.

    PubMed

    Palumbo, Barbara; Neumann, Irmgard; Havlik, Ernst; Palumbo, Renato; Sinzinger, Helmut

    2009-01-01

    During the last few years an increasing number of nuclear medicine patients in various countries evoked a radiation alarm after therapeutic or diagnostic procedures, and even after passive exposure. A prospective calculation of activity retention in the patient's body is difficult due to extremely high variation of uptake and kinetics. Furthermore, different sensitivities and distances of the detectors make a prospective calculation even more difficult. In this article a number of cases are being reported, related problems are discussed and the surprisingly very limited literature reviewed. In order to minimize problems after eventually triggering alarms, we strongly recommend that each patient receives a certificate providing personal data, tracer, dose, half-life of the radionuclide, type and date of procedure applied as well as the nuclear medicine unit to contact for further information. Furthermore, a closer cooperation and exchange of information between the authorities and local nuclear medicine societies, would be welcome.

  12. Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey

    PubMed Central

    Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    Objective We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. Materials and Methods We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. Results The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Conclusion Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion. PMID:26576117

  13. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    SciTech Connect

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-11-30

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added.

  14. A systematic review on diagnostic procedures for specific language impairment: The sensitivity and specificity issues

    PubMed Central

    Shahmahmood, Toktam Maleki; Jalaie, Shohreh; Soleymani, Zahra; Haresabadi, Fatemeh; Nemati, Parvin

    2016-01-01

    Background: Identification of children with specific language impairment (SLI) has been viewed as both necessity and challenge. Investigators and clinicians use different tests and measures for this purpose. Some of these tests/measures have good psychometric properties, but it is not sufficient for diagnostic purposes. A diagnostic procedure can be used for identification a specific population with confidence only when its sensitivity and specificity are acceptable. In this study, we searched for tests/measures with predefined sensitivity and specificity for identification of preschool children with SLI from their typically developing peers. Materials and Methods: A computerized search in bibliographic databases from 2000 to August 2015 was performed with the following keywords: “specific language impairment” or SLI” and “primary language impairment” or ‘PLI’ with at least one of the followings: “diagnosis,” “identification,” “accuracy,” “sensitivity,” and “specificity.” In addition, the related citations and reference lists of the selected articles were considered. Results: The results of reviewing 23 included studies show that the index measures used in studies vary in accuracy with the sensitivity ranging from 16% to 100% and the specificity ranging from 14% to 100%. Conclusion: These varieties in sensitivity and specificity of different tests/measures confirm the necessity of attention to the diagnostic power of tests/measures before their use as diagnostic tool. Further, the results indicate there are some promising tests/measures that the available evidence supports their performances in the diagnosis of SLI in preschool-aged children, yet the place of a reference standard for the diagnosis of SLI is vacant among investigations. PMID:27904612

  15. Validation of Three Early Ejaculation Diagnostic Tools: A Composite Measure Is Accurate and More Adequate for Diagnosis by Updated Diagnostic Criteria

    PubMed Central

    Jern, Patrick; Piha, Juhana; Santtila, Pekka

    2013-01-01

    Purpose To validate three early ejaculation diagnostic tools, and propose a new tool for diagnosis in line with proposed changes to diagnostic criteria. Significant changes to diagnostic criteria are expected in the near future. Available screening tools do not necessarily reflect proposed changes. Materials and Methods Data from 148 diagnosed early ejaculation patients (Mage = 42.8) and 892 controls (Mage = 33.1 years) from a population-based sample were used. Participants responded to three different questionnaires (Premature Ejaculation Profile; Premature Ejaculation Diagnostic Tool; Multiple Indicators of Premature Ejaculation). Stopwatch measured ejaculation latency times were collected from a subsample of early ejaculation patients. We used two types of responses to the questionnaires depending on the treatment status of the patients 1) responses regarding the situation before starting pharmacological treatment and 2) responses regarding current situation. Logistic regressions and Receiver Operating Characteristics were used to assess ability of both the instruments and individual items to differentiate between patients and controls. Results All instruments had very good precision (Areas under the Curve ranging from .93-.98). A new five-item instrument (named CHecklist for Early Ejaculation Symptoms – CHEES) consisting of high-performance variables selected from the three instruments had validity (Nagelkerke R2 range .51-.79 for backwards/forwards logistic regression) equal to or slightly better than any individual instrument (i.e., had slightly higher validity statistics, but these differences did not achieve statistical significance). Importantly, however, this instrument was more in line with proposed changes to diagnostic criteria. Conclusions All three screening tools had good validity. A new 5-item diagnostic tool (CHEES) based on the three instruments had equal or somewhat more favorable validity statistics compared to the other three tools, but is

  16. Reliability and Validity of a Procedure to Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    1990-01-01

    The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…

  17. Highly Reliable Procedural Teams: The Journey to Spread the Universal Protocol in Diagnostic Imaging

    PubMed Central

    Ross, Julie; Wolf, Debby; Reece, Kimberly

    2014-01-01

    Context: The Joint Commission’s Universal Protocol has been widely implemented in surgical settings since publication in 2003. The elements improved patient safety in operating rooms, and the same rigor is being applied to procedures occurring in other health care arenas, in particular, diagnostic imaging. Objective: In 2011, Kaiser Permanente West Los Angeles’s Diagnostic Imaging Department desired to adapt previous work on Universal Protocol implementation to improve patient safety in interventional radiology and mammography procedures. Design: The teams underwent human factors training and then adapted key interventions used in surgical suites to their workflows. Time-out posters, use of whiteboards, “glitch books,” and regular audits provided structure to overcome the risks that human factors present. Main Outcome Measures: Staff and physician perceptions of the teamwork and safety climates in their modalities were measured using the Safety Attitudes Questionnaire at baseline and at 18 months after training. Unusual Occurrence Reports were also reviewed to identify events and near misses that could be prevented. Implementation of key process changes were identified as process measures. Results: Perception of the safety climate improved 25% in interventional radiology and 4.5% in mammography. Perception of the teamwork climate decreased 5.4% in interventional radiology and 16.6% in mammography. Unusual occurrences were underreported at baseline, and there is ongoing reluctance to document near misses. Conclusion: This work provides important considerations of the impact of departmental cultures for the implementation of the Universal Protocol in procedural areas. It also reveals unexpected challenges, and requires long-term effort and focus. PMID:24626070

  18. Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India.

    PubMed

    Saravanakumar, A; Vaideki, K; Govindarajan, K N; Jayakumar, S

    2014-01-01

    Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDIw), volumetric CT dose index (CTDIv), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDIw, CTDIv, and DLP were calculated. The DRL is established based on the third quartile value of CTDIv and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level.

  19. Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India

    PubMed Central

    Saravanakumar, A.; Vaideki, K.; Govindarajan, K. N.; Jayakumar, S.

    2014-01-01

    Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDIw), volumetric CT dose index (CTDIv), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDIw, CTDIv, and DLP were calculated. The DRL is established based on the third quartile value of CTDIv and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level. PMID:24600173

  20. Non-inferiority test and confidence interval for the difference in correlated proportions in diagnostic procedures based on multiple raters.

    PubMed

    Saeki, Hiroyuki; Tango, Toshiro

    2011-12-10

    The efficacy of diagnostic procedures is generally evaluated on the basis of the results from multiple raters. However, there are few adequate methods of performing non-inferiority tests with confidence intervals to compare the accuracies (sensitivities or specificities) when multiple raters are considered. We propose new statistical methods for comparing the accuracies of two diagnostic procedures in a non-inferiority trial, on the basis of the results from multiple independent raters who are also independent of the study centers. We consider a study design in which each patient is subjected to two diagnostic procedures and all images are read by all raters. By assuming a multinomial distribution for matched-pair categorical data arising from the study design, we derive a score-based full menu, that is, a non-inferiority test, confidence interval and sample size formula, for inference of the difference in correlated proportions between the two diagnostic procedures. We conduct Monte Carlo simulation studies to examine the validity of the proposed methods, which showed that the proposed test has a size closer to the nominal significance level than a Wald-type test and that the proposed confidence interval has better empirical coverage probability than a Wald-type confidence interval. We illustrate the proposed methods with data from a study of diagnostic procedures for the diagnosis of oesophageal carcinoma infiltrating the tracheobronchial tree.

  1. Radiation Dose to the Skin and to the Gonads from Diagnostic X-Ray Procedures

    PubMed Central

    Duggan, H. E.; Olde, G. L.

    1963-01-01

    The design of a study to assess the hazard to patients from radiation received during diagnostic radiological procedures is described. The long-term accumulation of data relating to the skin and gonadal doses received by patients in a large x-ray department has been initiated. This will serve as a model for any situation involving small recurrent radiation doses to a significant proportion of the population. A description is given of the basic dose measurements made and the method used in calculating and recording the skin and gonadal doses for each patient. Although no definite conclusions concerning the presence or absence of a radiation hazard have yet been made, the proposed future course of this study is discussed. ImagesFig. 3Fig. 4 PMID:14079142

  2. Should excretory urography be used as a routine diagnostic procedure in patients with acute ureteric colic: a single center study.

    PubMed

    Samara, Osama A; Haroun, Dina A; Ashour, Do'a Z; Tarawneh, Emad S; Haroun, Azmi A

    2011-05-01

    The aim of this study was to find an accurate, easily available and safe imaging modality as an alternative to intravenous urography for the diagnosis of acute urinary obstruction. This retrospective study included 332 patients, who underwent both excretory urography (EU) preceeded by plain radiograph as well as ultrasonography for evaluation of acute flank pain. There were 198 male and 134 female patients. The presence or absence of urinary stones, level of obstruction, excretion delay on EU and dilated excretory system on either or both techniques were recorded. The sensitivity, specificity, predictive values, and accuracy for plain radiograph, ultrasonography, and for both modalities together were measured considering EU as a standard reference. The sensitivity and specificity of combined plain radiograph and ultrasound were 97% and 67%, respectively, with positive and negative predictive values and accuracy rates of 92%, 99%, and 97%, respectively. Our study suggests that the combination of plain radiograph and ultrasonography yields a high sensitivity, negative predictive value, and accuracy in depiction of urinary stones. Thus, EU need not be used as a routine diagnostic procedure in patients with acute obstructive uropathy.

  3. Use of diagnostic imaging procedures and fetal monitoring devices in the care of pregnant women.

    PubMed Central

    Moore, R M; Jeng, L L; Kaczmarek, R G; Placek, P J

    1990-01-01

    Medical devices and diagnostic imaging procedures such as ultrasound, X-rays, and electronic fetal monitoring devices are used in the medical care of many pregnant women today. The responsibility for the safety and effectiveness of these diagnostic technologies is shared by a number of Public Health Service agencies, one of which is the Center for Devices and Radiological Health (CDRH), a unit within the Food and Drug Administration. The CDRH collaborated with the National Center for Health Statistics (NCHS) in conducting a study of recent trends in the uses of diagnostic ultrasound, medical X-rays, and electronic fetal monitoring devices in the medical care of pregnant women. This study used data from the 1980 National Natality and Fetal Mortality Surveys and the 1987 pretest to the National Maternal and Infant Health Survey. Hospitals and prenatal care providers of the pregnant women contributed information regarding the use of these medical devices. Between 1980 and 1987, ultrasound use more than doubled, increasing from 33.5 percent of pregnancies in 1980 to 78.8 percent in 1987 (P less than 0.001). More ultrasound examinations were performed earlier in gestation in 1987 than in 1980, with 10.1 percent being performed during the first trimester in 1987, compared with 6.9 percent in 1980 (P less than 0.001). Use of external electronic fetal monitoring devices during delivery also increased significantly between 1980 and 1987, from 33.5 percent to 74.6 percent (P less than 0.001). Use of medical X-rays among women with live births remained relatively unchanged, 15.0 percent in 1980 and 15.3 percent in 1987 (P = .282). The implications of these trends are discussed. PMID:2120723

  4. The German Competence Net Dementias: standard operating procedures for the neurochemical dementia diagnostics.

    PubMed

    Lewczuk, P; Kornhuber, J; Wiltfang, J

    2006-08-01

    Aging of population results in an increasing number of patients with dementia. Therefore, recently a BMBF-supported project, Competence Net Dementia, was launched to reveal diagnostic, therapeutic, and epidemiologic aspects of demential disorders. In this project, our task was to establish and maintain human body fluids (HBF) bank to collect cerebrospinal fluid, plasma, serum, and full blood of patients enrolled into the study. As the pre-analytical sample handling is a prerequisite of all studies aiming at finding novel disease biomarkers, standard operating procedures (SOPs) were launched by our group to allow standardized collection, storage, and shipment of the samples among all 14 University centers involved in HBF collection. Currently, to our best knowledge the CND HBF bank represents one of the largest prospectively collected set of the samples from subjects with mild cognitive impairment and early dementias. With the samples collected in the HBF bank, recently introduced analytical technologies (like e.g. surface enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS), differential gel electrophoresis (DIGE), and multiplexing) can be promptly tested with regard to their potential usefulness in neurochemical dementia diagnostics.

  5. Lost in Translation? Ethical Challenges of Implementing a New Diagnostic Procedure.

    PubMed

    Schmitz, Dagmar

    2016-01-01

    Since cell-free DNA (cfDNA) fragments of placental origin can be isolated and analyzed from the blood of pregnant women. Applications of this finding have been developed and implemented in clinical care pathways worldwide at an unprecedented pace and manner. Implementation patterns, however, exhibit considerable insufficiencies. Different "motors" of implementation processes, like the market or various regulatory institutions, can be identified at a national level. Each "motor" entails characteristic ethical challenges which are exemplified impressively by a rising number of case reports.Empirical data demonstrate that there are significant "losses" in the respective translational processes, especially when the results from clinical research are to be translated into the clinical reality of NIPT (the so called "second roadblock" (T2)). These "losses" are perceived in the fields of knowledge transfer, professional standardization and ethical debate. Recommendations of professional organizations often fail to reach general practitioners. Blindsided by the new diagnostic procedure in their clinical practice, professionals in prenatal care express their insecurities with regard to its handling. Ethical debate appears to adhere to pre-existing (and partly already proven to be insufficient) normative frameworks for prenatal testing. While all of these deficits are typical for the implementation processes of many new molecular diagnostic procedures, especially in NIPT, they show a high variability between different nations.A critical assessment of the preferred strategy of implementation against the background of already existing national ethical frameworks is indispensable, if potential adverse effects are to be diminished. The described translational losses seem to be significantly reducible by granting the translational process in roadblock T2 more time.

  6. [Use of levofloxacin in the antibiotic prophylaxis for diagnostic procedures in urology].

    PubMed

    Trinchieri, Alberto; Mangiarotti, Barbara; Lizzano, Renata

    2002-03-01

    Chemoprophylaxis is the use of antimicrobial agents before contamination in the hope of preventing infections. The need for prophylaxis depends on the type of procedure and the risk for each individual patient. The risk for infection from urethral catheterization in a hospital setting is 5% for men and 10-20% for women, after routine cystoscopy is 4.7%, after transurethral resection of the bladder (TURB) is 39%, after transurethral resection of the prostate (TURP) is 6-43%, after transrectal biopsy of the prostate is 6.2-87%, and after shock wave lithotripsy is 5.7%. On this basis prophylactic treatment is recommended in all patients for transrectal prostate biopsy and transurethral surgery and in patients with increased risk of infection for diagnostic endoscopy of the urinary tract and SWL. Risk factors such as age, immunosuppression, metabolic dysfunction (e.g., diabetes), reduced general condition, prolonged operative time and bleeding, should be considered. Broad-spectrum cephalosporin, penicillins and fluoroquinolones are most often used. The choice of the drug also depends on its pharmacokinetic properties that should secure effective tissue levels during the procedure. Levofloxacin meets these criteria and reduces the incidence of infection after transrectal prostate biopsy and endoscopy of the urinary tract.

  7. Panel-based Genetic Diagnostic Testing for Inherited Eye Diseases is Highly Accurate and Reproducible and More Sensitive for Variant Detection Than Exome Sequencing

    PubMed Central

    Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.

    2015-01-01

    Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400

  8. Diagnostical mistakes in ablation procedures associated with a high placement of the leads V1-V3.

    PubMed

    Longo, Damián; Poliserpi, Claudio; Toscano Quilon, Francisco; Díaz Uberti, Pedro; López, Carlos; García-Niebla, Javier; Ramella, Irma

    2017-02-20

    The misplacement of electrodes for surface electrocardiogram (ECG) recording that we use daily as a reference for mapping precise locations in invasive procedures may, besides inducing diagnostical mistakes, greatly increase the duration of the procedure and making more feasible the incidence of complications, especially in ablation of arrhythmic substrates of ventricular outflow tracts such as premature ventricular contractions (PVC's) and accessory pathways, if the right precordial electrodes (V1-V3) are higher positioned.

  9. Can diagnostic and procedural skills required to practice cardiology as a specialist be mastered in 3 years?

    PubMed

    Yu, Eric H C; Nair, Parvathy; Sibbald, Matthew G; Lee, Douglas S; Dorian, Paul

    2015-01-01

    Cognitive and procedural skills required of cardiologists have increased in the past 10 years. What is unknown is whether residents consistently meet recommended volumes during training and what their own subjective assessments of their competency are after training. The purpose of this study was to (1) determine whether current training provides residents with opportunities to develop skills to function independently and (2) identify whether residents perceive gaps in their skills. We surveyed current and recent graduates of adult cardiology programs in Canada. One hundred ten responses from 425 surveys were received. Procedural and diagnostic test interpretation volumes were recorded, as were the optimum number the respondents believed were important to complete to function independently. These volumes were compared with the 2008 American College of Cardiology Core Cardiology Training Symposium (COCATS 3) and the Canadian Cardiovascular Society (CCS) recommendations for training. The proportion of residents meeting recommended volumes for diagnostic test interpretation ranged from 7% (Holter monitors) to 91% (echocardiograms). For procedures, the range was from 71% (echocardiography) to 100% (cardioversion). The ratio of residents' perceived minimum numbers believed to be required for proficiency for diagnostic test interpretation to those recommended ranged from 14% (electrocardiograms) to 116% (echocardiograms), and for procedures, the ratio was 66% (temporary pacemaker placement) to 116% (echocardiography). Recent graduates' perception of minimum required numbers to achieve competency is underestimated compared with COCATS 3 and CCS recommendations. Few graduates achieved the recommended volume targets suggested for diagnostic test interpretation.

  10. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false Procedures for public consultation for payment for a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... establishing payment amounts for the list of codes made available to the public. (c) Not fewer than 30...

  11. Metadata requirements for results of diagnostic imaging procedures: a BIIF profile to support user applications

    NASA Astrophysics Data System (ADS)

    Brown, Nicholas J.; Lloyd, David S.; Reynolds, Melvin I.; Plummer, David L.

    2002-05-01

    A visible digital image is rendered from a set of digital image data. Medical digital image data can be stored as either: (a) pre-rendered format, corresponding to a photographic print, or (b) un-rendered format, corresponding to a photographic negative. The appropriate image data storage format and associated header data (metadata) required by a user of the results of a diagnostic procedure recorded electronically depends on the task(s) to be performed. The DICOM standard provides a rich set of metadata that supports the needs of complex applications. Many end user applications, such as simple report text viewing and display of a selected image, are not so demanding and generic image formats such as JPEG are sometimes used. However, these are lacking some basic identification requirements. In this paper we make specific proposals for minimal extensions to generic image metadata of value in various domains, which enable safe use in the case of two simple healthcare end user scenarios: (a) viewing of text and a selected JPEG image activated by a hyperlink and (b) viewing of one or more JPEG images together with superimposed text and graphics annotation using a file specified by a profile of the ISO/IEC Basic Image Interchange Format (BIIF).

  12. A support vector machine model provides an accurate transcript-level-based diagnostic for major depressive disorder

    PubMed Central

    Yu, J S; Xue, A Y; Redei, E E; Bagheri, N

    2016-01-01

    Major depressive disorder (MDD) is a critical cause of morbidity and disability with an economic cost of hundreds of billions of dollars each year, necessitating more effective treatment strategies and novel approaches to translational research. A notable barrier in addressing this public health threat involves reliable identification of the disorder, as many affected individuals remain undiagnosed or misdiagnosed. An objective blood-based diagnostic test using transcript levels of a panel of markers would provide an invaluable tool for MDD as the infrastructure—including equipment, trained personnel, billing, and governmental approval—for similar tests is well established in clinics worldwide. Here we present a supervised classification model utilizing support vector machines (SVMs) for the analysis of transcriptomic data readily obtained from a peripheral blood specimen. The model was trained on data from subjects with MDD (n=32) and age- and gender-matched controls (n=32). This SVM model provides a cross-validated sensitivity and specificity of 90.6% for the diagnosis of MDD using a panel of 10 transcripts. We applied a logistic equation on the SVM model and quantified a likelihood of depression score. This score gives the probability of a MDD diagnosis and allows the tuning of specificity and sensitivity for individual patients to bring personalized medicine closer in psychiatry. PMID:27779627

  13. Procedure for computer-controlled milling of accurate surfaces of revolution for millimeter and far-infrared mirrors

    NASA Technical Reports Server (NTRS)

    Emmons, Louisa; De Zafra, Robert

    1991-01-01

    A simple method for milling accurate off-axis parabolic mirrors with a computer-controlled milling machine is discussed. For machines with a built-in circle-cutting routine, an exact paraboloid can be milled with few computer commands and without the use of the spherical or linear approximations. The proposed method can be adapted easily to cut off-axis sections of elliptical or spherical mirrors.

  14. CT-guided percutaneous aspiration of Tarlov cyst as a useful diagnostic procedure prior to operative intervention.

    PubMed

    Lee, J-Y; Impekoven, P; Stenzel, W; Löhr, M; Ernestus, R-I; Klug, N

    2004-07-01

    Tarlov or perineural cysts are lesions of the nerve root most often found in the sacral region. Several authors recommend surgical treatment of symptomatic Tarlov cysts. However, successful surgical treatment is dependent on appropriate patient selection. In this article, we report three cases of a sacral perineural cyst, causing sciatic pain, and emphasize the usefulness of CT-guided percutaneous aspiration as an important diagnostic and prognostic procedure prior to definitive operative treatment.

  15. Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis.

    PubMed

    Bespamyatnov, Igor O; Rowan, William L; Granetz, Robert S

    2008-10-01

    Charge exchange recombination spectroscopy on Alcator C-Mod relies on the use of the diagnostic neutral beam injector as a source of neutral particles which penetrate deep into the plasma. It employs the emission resulting from the interaction of the beam atoms with fully ionized impurity ions. To interpret the emission from a given point in the plasma as the density of emitting impurity ions, the density of beam atoms must be known. Here, an analysis of beam propagation is described which yields the beam density profile throughout the beam trajectory from the neutral beam injector to the core of the plasma. The analysis includes the effects of beam formation, attenuation in the neutral gas surrounding the plasma, and attenuation in the plasma. In the course of this work, a numerical simulation and an analytical approximation for beam divergence are developed. The description is made sufficiently compact to yield accurate results in a time consistent with between-shot analysis.

  16. Retrospective screening of relevant pesticide metabolites in food using liquid chromatography high resolution mass spectrometry and accurate-mass databases of parent molecules and diagnostic fragment ions.

    PubMed

    Polgár, László; García-Reyes, Juan F; Fodor, Péter; Gyepes, Attila; Dernovics, Mihály; Abrankó, László; Gilbert-López, Bienvenida; Molina-Díaz, Antonio

    2012-08-03

    In recent years, the detection and characterization of relevant pesticide metabolites in food is an important task in order to evaluate their formation, kinetics, stability, and toxicity. In this article, a methodology for the systematic screening of pesticides and their main metabolites in fruit and vegetable samples is described, using LC-HRMS and accurate-mass database search of parent compounds and their diagnostic fragment ions. The approach is based on (i) search for parent pesticide molecules; (ii) search for their metabolites in the positive samples, assuming common fragmentation pathways between the metabolites and parent pesticide molecules; and (iii) search for pesticide conjugates using the data from both parent species and diagnostic fragment ions. An accurate-mass database was constructed consisting of 1396 compounds (850 parent compounds, 447 fragment ions and 99 metabolites). The screening process was performed by the software in an automated fashion. The proposed methodology was evaluated with 29 incurred samples and the output obtained was compared to standard pesticide testing methods (targeted LC-MS/MS). Examples on the application of the proposed approach are shown, including the detection of several pesticide glycosides derivatives, which were found with significantly relevant intensities. Glucose-conjugated forms of parent compounds (e.g., fenhexamid-O-glucoside) and those of metabolites (e.g., despropyl-iprodione-N-glycoside) were detected. Facing the lack of standards for glycosylated pesticides, the study was completed with the synthesis of fenhexamid-O-glucoside for quantification purposes. In some cases the pesticide derivatives were found in a relatively high ratio, drawing the attention to these kinds of metabolites and showing that they should not be neglected in multi-residue methods. The global coverage obtained on the 29 analyzed samples showed the usefulness and benefits of the proposed approach and highlights the practical

  17. Italian Frontotemporal Dementia Network (FTD Group-SINDEM): sharing clinical and diagnostic procedures in Frontotemporal Dementia in Italy.

    PubMed

    Borroni, B; Turrone, R; Galimberti, D; Nacmias, B; Alberici, A; Benussi, A; Caffarra, P; Caltagirone, C; Cappa, S F; Frisoni, G B; Ghidoni, R; Marra, C; Padovani, A; Rainero, I; Scarpini, E; Silani, V; Sorbi, S; Tagliavini, F; Tremolizzo, L; Bruni, A C

    2015-05-01

    In the prospect of improved disease management and future clinical trials in Frontotemporal Dementia, it is desirable to share common diagnostic procedures. To this aim, the Italian FTD Network, under the aegis of the Italian Neurological Society for Dementia, has been established. Currently, 85 Italian Centers involved in dementia care are part of the network. Each Center completed a questionnaire on the local clinical procedures, focused on (1) clinical assessment, (2) use of neuroimaging and genetics; (3) support for patients and caregivers; (4) an opinion about the prevalence of FTD. The analyses of the results documented a comprehensive clinical and instrumental approach to FTD patients and their caregivers in Italy, with about 1,000 newly diagnosed cases per year and 2,500 patients currently followed by the participating Centers. In analogy to other European FTD consortia, future aims will be devoted to collect data on epidemiology of FTD and its subtypes and to provide harmonization of procedures among Centers.

  18. Fast and accurate calibration of an X-ray imager to an electromagnetic tracking system for interventional cardiac procedures.

    PubMed

    Lang, Andrew; Stanton, Douglas; Parthasarathy, Vijay; Jain, Ameet

    2010-01-01

    Cardiovascular disease affects millions of Americans each year. Interventional guidance systems are being developed as treatment options for some of the more delicate procedures, including targeted stem cell therapy. As advanced systems for such types of interventional guidance are being developed, electromagnetic (EM) tracking is coming in demand to perform navigation. To use this EM tracking technology, a calibration is necessary to register the tracker to the imaging system. In this paper we investigate the calibration of an X-ray imaging system to EM tracking. Two specially designed calibration phantoms have been designed for this purpose, each having a rigidly attached EM sensor. From a clinical usability point-of-view, we propose to divide this calibration problem into two steps: i) in initial calibration of the EM sensor to the phantom design using an EM tracked needle to trace out grooves in the phantom surface and ii) segmentation from X-ray images and 3D reconstruction of beads embedded in the phantom in a known geometric pattern. Combining these two steps yields and X-ray-to-EM calibration accuracy of less than 1 mm when overlaying an EM tracked needle on X-ray images.

  19. The London Procedure: A Screening Diagnostic and Teaching Guide for Adult Learning Problems.

    ERIC Educational Resources Information Center

    Travis, George Y.; And Others

    1978-01-01

    Describes development, composition, and interpretation of a series of individually administered tests to identify adult basic education learning problems. Test areas include screening for visual/auditory functions and diagnostic evaluation of visual/auditory perceptions and dyslexia. Results can provide basis for referral to medical or visual…

  20. Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures; Federal Guidance Report No. 14

    EPA Science Inventory

    Federal Guidance Report No. 14 provides federal facilities that use diagnostic and interventional x-ray equipment with updated recommendations for keeping doses as low as reasonably achievable without compromising the quality of patient care, This guidance is an update of Federal...

  1. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests.

    PubMed

    Shan, Guogen; Amei, Amei; Young, Daniel

    2015-01-01

    Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003). However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  2. Diagnostic procedures for non-small-cell lung cancer (NSCLC): recommendations of the European Expert Group

    PubMed Central

    Dietel, Manfred; Bubendorf, Lukas; Dingemans, Anne-Marie C; Dooms, Christophe; Elmberger, Göran; García, Rosa Calero; Kerr, Keith M; Lim, Eric; López-Ríos, Fernando; Thunnissen, Erik; Van Schil, Paul E; von Laffert, Maximilian

    2016-01-01

    Background There is currently no Europe-wide consensus on the appropriate preanalytical measures and workflow to optimise procedures for tissue-based molecular testing of non-small-cell lung cancer (NSCLC). To address this, a group of lung cancer experts (see list of authors) convened to discuss and propose standard operating procedures (SOPs) for NSCLC. Methods Based on earlier meetings and scientific expertise on lung cancer, a multidisciplinary group meeting was aligned. The aim was to include all relevant aspects concerning NSCLC diagnosis. After careful consideration, the following topics were selected and each was reviewed by the experts: surgical resection and sampling; biopsy procedures for analysis; preanalytical and other variables affecting quality of tissue; tissue conservation; testing procedures for epidermal growth factor receptor, anaplastic lymphoma kinase and ROS proto-oncogene 1, receptor tyrosine kinase (ROS1) in lung tissue and cytological specimens; as well as standardised reporting and quality control (QC). Finally, an optimal workflow was described. Results Suggested optimal procedures and workflows are discussed in detail. The broad consensus was that the complex workflow presented can only be executed effectively by an interdisciplinary approach using a well-trained team. Conclusions To optimise diagnosis and treatment of patients with NSCLC, it is essential to establish SOPs that are adaptable to the local situation. In addition, a continuous QC system and a local multidisciplinary tumour-type-oriented board are essential. PMID:26530085

  3. Explicitly correlated benchmark calculations on C8H8 isomer energy separations: how accurate are DFT, double-hybrid, and composite ab initio procedures?

    NASA Astrophysics Data System (ADS)

    Karton, Amir; Martin, Jan M. L.

    2012-10-01

    Accurate isomerization energies are obtained for a set of 45 C8H8 isomers by means of the high-level, ab initio W1-F12 thermochemical protocol. The 45 isomers involve a range of hydrocarbon functional groups, including (linear and cyclic) polyacetylene, polyyne, and cumulene moieties, as well as aromatic, anti-aromatic, and highly-strained rings. Performance of a variety of DFT functionals for the isomerization energies is evaluated. This proves to be a challenging test: only six of the 56 tested functionals attain root mean square deviations (RMSDs) below 3 kcal mol-1 (the performance of MP2), namely: 2.9 (B972-D), 2.8 (PW6B95), 2.7 (B3PW91-D), 2.2 (PWPB95-D3), 2.1 (ωB97X-D), and 1.2 (DSD-PBEP86) kcal mol-1. Isomers involving highly-strained fused rings or long cumulenic chains provide a 'torture test' for most functionals. Finally, we evaluate the performance of composite procedures (e.g. G4, G4(MP2), CBS-QB3, and CBS-APNO), as well as that of standard ab initio procedures (e.g. MP2, SCS-MP2, MP4, CCSD, and SCS-CCSD). Both connected triples and post-MP4 singles and doubles are important for accurate results. SCS-MP2 actually outperforms MP4(SDQ) for this problem, while SCS-MP3 yields similar performance as CCSD and slightly bests MP4. All the tested empirical composite procedures show excellent performance with RMSDs below 1 kcal mol-1.

  4. Theoretical modelling of experimental diagnostic procedures employed during pre-dose dosimetry of quartz.

    PubMed

    Pagonis, Vasilis; Chen, Reuven; Kitis, George

    2006-01-01

    The pre-dose technique in thermoluminescence (TL) is used for dating archaeological ceramics and for accident dosimetry. During routine applications of this technique, the sensitisation of the quartz samples is measured as a function of the annealing temperature, yielding the so-called thermal activation characteristic (TAC). The measurement of multiple TACs and the study of the effect of UV-radiation on the TL sensitivity of quartz are important analytical and diagnostic tools. In this paper, it is shown that a modified Zimmerman model for quartz can successfully model the experimental steps undertaken during a measurement of multiple TACs.

  5. The Australian experiment: the use of evidence based medicine for the reimbursement of surgical and diagnostic procedures (1998–2004)

    PubMed Central

    O'Malley, Sue P

    2006-01-01

    Background In 1998 a formal process using the criteria of safety, effectiveness and cost-effectiveness (evidence based medicine) on the introduction and use of new medical procedures was implemented in Australia. As part of this process an expert panel, the Medical Services Advisory Committee (MSAC) was set up. This paper examines the effectiveness of this process based on the original criteria, that is, evidence based medicine. Method The data for this analysis was sourced primarily from that made available in the public domain. The MSAC web site provided Minutes from MSAC meetings; Annual Reports; Assessment and Review reports; Progress status; and Archived material. Results The total number of applications submitted to the MSAC has been relatively low averaging approximately only fourteen per year. Additionally, the source of applications has quickly shifted to the medical devices, equipment and diagnostic industry as being the major source of applications. An overall average time for the processing of an application is eighteen months. Negative recommendations were in most cases based on insufficient clinical evidence rather than clinical evidence that clearly demonstrated a lack of clinical effectiveness. It was rare for a recommendation, either positive or negative, to be based on cost-effectiveness. Conclusion New medical procedures are often the result of a process of experimentation rather than formally conducted research. Affordability and the question of who should pay for the generation, collection and analysis of the clinical evidence is perhaps the most difficult to answer. This is especially the case where the new procedure is the result of a process of experimentation with an old procedure. A cost-effective way needs to be found to collect acceptable levels of evidence proving the clinical effectiveness of these new procedures, otherwise the formal processes of evaluation such as that used by the Australian MSAC since 1998 will continue to run the

  6. Procedures to minimize diagnostic x-ray exposure of the human embryo and fetus. Final report

    SciTech Connect

    Not Available

    1980-08-01

    The recommendations published here are intended for the attending physician, the radiologist, the technologist, and the patient, delineating their respective roles in optimizing the x-ray exposure of pregnant or potentially pregnant women. These recommendations emphasize the necessity for attending physicians to determine whether or not their patients might be pregnant and to use this information in deciding on the need for an x-ray examination. The recommendations also stress the need to reduce x-ray exposure throughout gestation, and suggest ways in which this can be accomplished. X-ray exposure of the developing embryo and fetus has been a matter of concern for many years. Several national and international organizations have developed guidelines or policy statements on the subject. The BRH recommendations are expansions of the conceptual foundations provided by these other organizations, and they clarify the ways in which medical radiation exposure can be minimized without compromising the medical care of the mother. These recommendations are based on the principle that unnecessary or unproductive medical radiation exposure should be avoided or reduced to the extent possible, while preserving and improving the anticipated benefits of radiological diagnostic information. As with all medical applications of ionizing radiation, the physician's decision to obtain a diagnostic x-ray examination of a pregnant or potentially pregnant patient should be based on the judgment that the medical information obtained is likely to be important for appropriate patient management.

  7. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures

    PubMed Central

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P.

    2012-01-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging. PMID:22639482

  8. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures.

    PubMed

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P

    2012-04-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging.

  9. A World Allergy Organization International Survey on Diagnostic Procedures and Therapies in Drug Allergy/Hypersensitivity

    PubMed Central

    Mirakian, Rita; Castells, Mariana; Pichler, Werner; Romano, Antonino; Bonadonna, Patrizia; Diana, Deleanu; Kowalski, Marek; Yanez, Anahi; Lleonart, Ramon; Sanchez-Borges, Mario; Demoly, Pascal

    2011-01-01

    Objective To study the diagnostic and treatment modalities used in drug allergy/hypersensitivity among members of the World Allergy Organization (WAO). Methods A questionnaire comprising 39 questions was circulated electronically to member societies, associate member societies, and regional and affiliate organizations of WAO between June 29, 2009, and August 9, 2009. Results Eighty-two responses were received. Skin testing was used by 74.7%, with only 71.4% having access to penicillin skin test reagents. In vitro–specific IgE tests were used by 67.4%, and basophil activation test was used by 54.4%. Lymphocyte transformation tests were used by 36.8% and patch tests by 54.7%. Drug provocation tests were used by 68.4%, the most common indication being to exclude hypersensitivity where history/symptoms were not suggestive of drug hypersensitivity/allergy (76.9%). Rapid desensitization for chemotherapy, antibiotics, or biologic agents was used by 69.6%. Systemic corticosteroid was used in the treatment of Stevens–Johnson syndrome by 72.3%, and high-dose intravenous immunoglobulins in toxic epidermal necrolysis by 50.8%. Human leukocyte antigen screening before prescription of abacavir was used by 92.9% and before prescription of carbamazepine by 21.4%. Conclusions Results of this survey form a useful framework for developing educational and training needs and for improving access to drug allergy diagnostic and treatment modalities across WAO member societies. PMID:23268453

  10. Work-related stress and bullying: gender differences and forensic medicine issues in the diagnostic procedure

    PubMed Central

    2011-01-01

    Background The attention of international agencies and scientific community on bullying and work-related stress is increasing. This study describes the gender differences found in victims of bullying and work-related stress in an Italian case series and analyzes the critical issues in the diagnostic workup. Methods Between 2001 and 2009 we examined 345 outpatients (148 males, 197 females; mean age: 41 ± 10.49) for suspected psychopathological work-related problems. Diagnosis of bullying was established using international criteria (ICD-10 and DSM-IV). Results After interdisciplinary diagnostic evaluation (Occupational Medicine Unit, Psychology and Psychiatry Service), the diagnosis of bullying was formulated in 35 subjects, 12 males and 23 females (2 cases of Post-Traumatic Stress Disorder and 33 of Adjustment Disorder). Fifty-four (20 males, 34 females) suffered from work-related anxiety, while work-unrelated Adjustment Disorder and other psychiatric disorders were diagnosed in 7 and 112 subjects, respectively. Women between 34 and 45 years showed a high prevalence (65%) of "mobbing syndrome" or other work-related stress disorders. Conclusions At work, women are more subject to harassment (for personal aspects related to emotional and relational factors) than men. The knowledge of the phenomenon is an essential requisite to contrast bullying; prevention can be carried out only through effective information and training of workers and employers, who have the legal obligation to preserve the integrity of the mental and physical status of their employees during work. PMID:22088163

  11. [Quantitative measures for assessing the functional state of the human body during diagnostic procedure].

    PubMed

    Artemenko, M V

    2008-01-01

    Two approaches to calculation of the qualitative measures for assessing the functional state level of human body are considered. These approaches are based on image and fuzzy set recognition theories and are used to construct diagnostic decision rules. The first approach uses the data on deviation of detected parameters from those for healthy persons; the second approach analyzes the degree of deviation of detected parameters from the approximants characterizing the correlation differences between the parameters. A method for synthesis of decision rules and the results of blood count-based research for a number of diseases (hemophilia, thrombocytopathy, hypertension, arrhythmia, hepatic cirrhosis, trichophytia) are considered. An effect of a change in the functional link between the cholesterol content in blood and the relative rate of variation of AST and ALT enzymes in blood from direct proportional (healthy state) to inverse proportional (hepatic cirrhosis) is discussed. It is shown that analysis of correlation changes in detected parameters of the human body state during diagnostic process is more effective for application in decision support systems than the state space analysis.

  12. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) The test system shall send a Mode $01, PID $01 request in accordance with SAE J1979 to determine the... in accordance with SAE J1979. The procedure shall be done in accordance with SAE J1979 “E/E... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of SAE J1979 may be obtained from...

  13. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) The test system shall send a Mode $01, PID $01 request in accordance with SAE J1979 to determine the... in accordance with SAE J1979. The procedure shall be done in accordance with SAE J1979 “E/E... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of SAE J1979 may be obtained from...

  14. Improved microwave-assisted wet digestion procedures for accurate Se determination in fish and shellfish by flow injection-hydride generation-atomic absorption spectrometry.

    PubMed

    Lavilla, I; González-Costas, J M; Bendicho, C

    2007-05-22

    Accurate determination of Se in biological samples, especially fish and shellfish, by hydride generation techniques has generally proven troublesome owing to the presence of organoselenium that cannot readily converted into inorganic selenium under usual oxidising conditions. Further improvements in the oxidation procedures are needed so as to obtain accurate concentration values when this type of samples is analyzed. Microwave-assisted wet digestion (MAWD) procedures of seafood based on HNO3 or the mixture HNO3/H2O2 and further thermal reduction of the Se(VI) formed to Se(IV) were evaluated. These procedures were as follows: (I) without H2O2 and without heating to dryness; (II) without H2O2 and with heating to dryness; (III) with H2O2 and without heating to dryness; (IV) with H2O2 and with heating to dryness. In general, low recoveries of selenium are obtained for several marine species (e.g., crustaceans and cephalopods), which may be ascribed to the presence of Se forms mainly associated with nonpolar proteins and lipids. Post-digestion UV irradiation proved very efficient since not only complete organoselenium decomposition was achieved but also the final step required for prereduction of Se(VI) into Se(IV) (i.e. heating at 90 degrees C for 30 min in 6M HCl) could be avoided. With the MAWD/UV procedure, the use of strong oxidising agents (persuphate, etc.) or acids (e.g. perchloric acid) which are typically applied prior to Se determination by hydride generation techniques is overcome, and as a result, sample pre-treatment is significantly simplified. The method was successfully validated against CRM DOLT-2 (dogfish liver), CRM DORM-2 (dogfish muscle) and CRM TORT-2 (lobster hepatopancreas). Automated ultrasonic slurry sampling with electrothermal atomic absorption spectrometry was also applied for comparison. Total Se contents in ten seafood samples were established. Se levels ranged from 0.7 to 2.9 microg g(-1).

  15. Diagnostic procedures in tularaemia with special focus on molecular and immunological techniques.

    PubMed

    Splettstoesser, W D; Tomaso, H; Al Dahouk, S; Neubauer, H; Schuff-Werner, P

    2005-08-01

    Tularaemia is a severe bacterial zoonosis caused by the highly infectious agent Francisella tularensis. It is endemic in countries of the northern hemisphere ranging from North America to Europe, Asia and Japan. Very recently, Francisella-like strains causing disease in humans were described from tropical northern Australia. In the last decade, efforts have been made to develop sensitive and specific immunological and molecular techniques for the laboratory diagnosis of tularaemia and also for the definite identification of members of the species F. tularensis and its four subspecies. Screening for the keyword 'Francisella' a Medline search over the last decade was performed and articles describing diagnostic methods for tularaemia and its causative agent were selected. Besides classical microbiological techniques (cultivation, biochemical profiling, susceptibility testing) several new immunological and molecular approaches to identify F. tularensis have been introduced employing highly specific antibodies and various polymerase chain reaction (PCR)-based methods. Whereas direct antigen detection by enzyme-linked immunosorbent assay (ELISA) or immunofluorescence might allow early presumptive diagnosis of tularaemia, these methods--like all PCR techniques--still await further evaluation. Therefore, diagnosis of tularaemia still relies mainly on the demonstration of specific antibodies in the host. ELISA and immunoblot methods started to replace the standard tube or micro-agglutination assays. However, the diagnostic value of antibody detection in the very early clinical phase of tularaemia is limited. Francisella tularensis is regarded as a 'highest priority' biological agent (category 'A' according to the CDC, Atlanta, GA, USA), thus rapid and reliable diagnosis of tularaemia is required not only for a timely onset of therapy, the handling of outbreak investigations but also for the surveillance of endemic foci. Only very recently, evaluated test kits for

  16. Accurate and self-consistent procedure for determining pH in seawater desalination brines and its manifestation in reverse osmosis modeling.

    PubMed

    Nir, Oded; Marvin, Esra; Lahav, Ori

    2014-11-01

    Measuring and modeling pH in concentrated aqueous solutions in an accurate and consistent manner is of paramount importance to many R&D and industrial applications, including RO desalination. Nevertheless, unified definitions and standard procedures have yet to be developed for solutions with ionic strength higher than ∼0.7 M, while implementation of conventional pH determination approaches may lead to significant errors. In this work a systematic yet simple methodology for measuring pH in concentrated solutions (dominated by Na(+)/Cl(-)) was developed and evaluated, with the aim of achieving consistency with the Pitzer ion-interaction approach. Results indicate that the addition of 0.75 M of NaCl to NIST buffers, followed by assigning a new standard pH (calculated based on the Pitzer approach), enabled reducing measured errors to below 0.03 pH units in seawater RO brines (ionic strength up to 2 M). To facilitate its use, the method was developed to be both conceptually and practically analogous to the conventional pH measurement procedure. The method was used to measure the pH of seawater RO retentates obtained at varying recovery ratios. The results matched better the pH values predicted by an accurate RO transport model. Calibrating the model by the measured pH values enabled better boron transport prediction. A Donnan-induced phenomenon, affecting pH in both retentate and permeate streams, was identified and quantified.

  17. Rapid sandwich ELISA-based in vitro diagnostic procedure for the highly-sensitive detection of human fetuin A.

    PubMed

    Vashist, Sandeep Kumar; Schneider, E Marion; Luong, John H T

    2015-05-15

    A rapid sandwich enzyme-linked immunosorbent assay (ELISA)-based in vitro diagnostic (IVD) procedure has been developed for human fetuin A (HFA), an important disease biomarker for inflammatory diseases as well as malignancies. In this simplified and cost-effective procedure, the EDC-activated anti-HFA antibody (Ab) was admixed with 1% (v/v) 3-aminopropyltriethoxysilane (APTES) in 1:1 (v/v) and dispensed in a KOH-pretreated microtiter plate (MTP). APTES formed a stable complex with the capture antibody that was in turn covalently bonded on the KOH-treated surface in 30 min. The resulting immunoassay (IA) format detects HFA with a dynamic range of 0.1-243 ng mL(-1), and a limit of detection (LOD) and analytical sensitivity of 0.3 ng mL(-1) and 1.0 ng mL(-1), respectively. For the determination of HFA spiked in diluted human whole blood and serum, and HFA in ethylenediaminetetraacetic acid (EDTA)-plasma of patients, the obtained analytical precision is similar to that of the conventional sandwich ELISA. The anti-HFA Ab-bound MTPs, stored at 4 °C in 0.1M PBS, pH 7.4, retained its biological activity for 8 weeks, thereby demonstrating excellent storage stability. This generic sandwich ELISA procedure can be extended for rapid, simplified and cost-effective detection of other disease biomarkers.

  18. Degree of Vertical Integration Between the Undergraduate Program and Clinical Internship With Respect to Cervical and Cranial Diagnostic and Therapeutic Procedures Taught at the Canadian Memorial Chiropractic College

    PubMed Central

    Leppington, Charmody; Gleberzon, Brian; Fortunato, Lisa; Doucet, Nicolea; Vandervalk, Kyle

    2012-01-01

    Objective: The purpose of this study was to determine if diagnostic and therapeutic procedures for the cervical and cranial spine taught to students during the undergraduate program at Canadian Memorial Chiropractic College are required to be used during their internship by their supervising clinicians and, if so, to what extent these procedures are used. Methods: Course manuals and course syllabi from the Applied Chiropractic and Clinical Diagnosis faculty of the undergraduate chiropractic program for the academic year 2009–2010 were consulted and a list of all diagnostic and therapeutic procedures for the cranial and cervical spine was compiled. This survey asked clinicians to indicate if they themselves used or if they required the students they were supervising to use each procedure listed and, if so, to what extent each procedure was used. Demographic information of each clinician was also obtained. Results: In general, most diagnostic procedures of the head and neck were seldom used, with the exception of postural observation and palpation. By contrast, most cervical orthopaedic tests were often used, with the exception of tests for vertigo. Most therapeutic procedures were used frequently with the exception of prone cervical and “muscle” adjustments. Conclusion: There was a low degree of vertical integration for cranial procedures as compared to a much higher degree of vertical integration for cervical procedures between the undergraduate and clinical internship programs taught. Vertical integration is an important element of curricular planning and these results may be helpful to aid educators to more appropriately allocate classroom instruction PMID:22778531

  19. Smart on-board diagnostic decision trees for quantitative aviation equipment and safety procedures validation

    NASA Astrophysics Data System (ADS)

    Ali, Ali H.; Markarian, Garik; Tarter, Alex; Kölle, Rainer

    2010-04-01

    The current trend in high-accuracy aircraft navigation systems is towards using data from one or more inertial navigation subsystem and one or more navigational reference subsystems. The enhancement in fault diagnosis and detection is achieved via computing the minimum mean square estimate of the aircraft states using, for instance, Kalman filter method. However, this enhancement might degrade if the cause of a subsystem fault has some effect on other subsystems that are calculating the same measurement. One instance of such case is the tragic incident of Air France Flight 447 in June, 2009 where message transmissions in the last moment before the crash indicated inconsistencies in measured airspeed as reported by Airbus. In this research, we propose the use of mathematical aircraft model to work out the current states of the airplane and in turn, using these states to validate the readings of the navigation equipment throughout smart diagnostic decision tree network. Various simulated equipment failures have been introduced in a controlled environment to proof the concept of operation. The results have showed successful detection of the failing equipment in all cases.

  20. [The syndrome of increased upper airways resistance: What are the clinical features and diagnostic procedures?].

    PubMed

    M'saad, S; Yangui, I; Feki, W; Abid, N; Bahloul, N; Marouen, F; Chakroun, A; Kammoun, S

    2015-12-01

    The upper airway resistance syndrome "UARS" is a poorly defined entity, often described as a moderate variant of the obstructive sleep apnea syndrome. It is associated with respiratory effort-related arousal, absence of obstructive sleep apnea, and absence of significant desaturation. It is a relatively common condition that predominantly affects non-obese young adults, with no predominance in either sex. The degree of upper airway collapsibility during sleep of patients with UARS is intermediate between that of normal subjects and that of patients with mild-to-moderate sleep apnea syndrome. Craniofacial and palatal abnormalities are often noted. Patients frequently complain of a functional somatic syndrome, especially daytime sleepiness and chronic fatigue. Polysomnography with esophageal pressure measurements remains the gold standard diagnostic test. The absence of any neurological abnormality gives UARS a good prognosis and it is potentially reversible if treated early. However, some studies suggest that untreated UARS has an increased risk of arterial hypertension. It can also evolve into obstructive sleep apnea.

  1. Serum concentrations of prostate-specific antigen after diagnostic procedures and transurethral microwave thermotherapy of benign prostatic hyperplasia.

    PubMed

    Daehlin, L; Frugård, J; Farstad, M

    1996-05-01

    The objective was to study the effects of diagnostic and therapeutic procedures on serum prostate-specific antigen (PSA) concentration. Urethrocystoscopy in combination with digital rectal examination was followed by a moderate increase of serum PSA for 7-10 days. At 1 day after transurethral microwave thermotherapy (TUMT), an acute and pronounced effect on PSA was observed, which returned to baseline level after 4 weeks. The initial rise in serum PSA corresponded to a PSA density of 1.11, compared to 0.07 at baseline. The present data should be taken into consideration in conjunction with endoscopic evaluation of the lower urinary tract. Additionally, the acute effect on PSA after TUMT strongly suggests the ability of thermotherapy to induce cellular injury and death. One-year follow-up, however, was associated with increased PSA levels, indicating that only a minor part of the PSA-producing compartment was lost in the acute phase.

  2. Fructose breath hydrogen test--is it really a harmless diagnostic procedure?

    PubMed

    Müller, P; Meier, C; Böhme, H J; Richter, T

    2003-01-01

    Usage of hydrogen breath tests has become one of the standard procedures in diagnosing chronic unspecific abdominal pain. These tests are said to be of sufficient specificity and sensitivity, are easily done, non-invasive and are more often practiced in outpatients. A 13-year-old boy is reported with chronic unspecific abdominal pain and growth retardation and so far misdiagnosed hereditary fructose intolerance (HFI), who developed life-threatening adverse effects during the fructose breath hydrogen test. It is concluded that the possibility of HFI should be excluded first by a carefully explored dietary history before the fructose breath test is performed under medical supervision. If there is any suspicion of HFI, a molecular genetic analysis should be preferred.

  3. Application of Routine Diagnostic Procedure, VITEK 2 Compact, MALDI-TOF MS, and PCR Assays in Identification Procedure of Bacterial Strain with Ambiguous Phenotype.

    PubMed

    Książczyk, Marta; Kuczkowski, Maciej; Dudek, Bartłomiej; Korzekwa, Kamila; Tobiasz, Anna; Korzeniowska-Kowal, Agnieszka; Paluch, Emil; Wieliczko, Alina; Bugla-Płoskońska, Gabriela

    2016-05-01

    In diagnostic microbiology as well as in microbiological research, the identification of a microorganism is a crucial and decisive stage. A broad choice of methods is available, based on both phenotypic and molecular properties of microbes. The aim of this study was to compare the application of phenotypic and molecular tools in bacterial identification on the example of Gram-negative intestine rod with an ambiguous phenotype. Different methods of identification procedure, which based on various properties of bacteria, were applied, e.g., microscopic observation of single-bacterial cells, macroscopic observation of bacterial colonies morphology, the automated system of microorganism identification (biochemical tests), the mass spectrometry method (analysis of bacterial proteome), and genetic analysis with PCR reactions. The obtained results revealed discrepancies in the identification of the tested bacterial strain with an atypical phenotype: mucous morphology of colonies, not characteristic for either E. coli and Citrobacter spp., mass spectrometry analysis of proteome initially assigned the tested strain to Citrobacter genus (C. freundii) and biochemical profiles pointed to Escherichia coli. A decisive method in the current study was genetic analysis with PCR reactions which identified conserved genetic sequences highly specific to E. coli species in the genome of the tested strain.

  4. Pulmonary infiltrates in non-HIV immunocompromised patients: a diagnostic approach using non-invasive and bronchoscopic procedures

    PubMed Central

    Rano, A; Agusti, C; Jimenez, P; Angrill, J; Benito, N; Danes, C; Gonzalez, J; Rovira, M; Pumarola, T; Moreno, A; Torres, A

    2001-01-01

    %); and TBAS 35/55 (65%). Bronchoscopic techniques led to the diagnosis of pulmonary infiltrates in 59% of the cases in which they were used: FBAS 16/28 (57%), BAL 68/135 (51%), and PSB 30/125 (24%). The results obtained with the different techniques led to a change in antibiotic treatment in 93 cases (46%). Although changes in treatment did not have an impact on the overall mortality, patients with pulmonary infiltrates of an infectious aetiology in whom the change was made during the first 7 days had a better outcome (29% mortality) than those in whom treatment was changed later (71% mortality; p=0.001).
CONCLUSIONS—Non-invasive and bronchoscopic procedures are useful techniques for the diagnosis of pulmonary infiltrates in immunocompromised patients. Bronchial aspirates (FBAS and TBAS) and BAL have the highest diagnostic yield and impact on therapeutic decisions.

 PMID:11312407

  5. Evolving American Society for Testing and Materials (ASTM) Procedures On Use Of Infrared (IR) Imaging Devices For Building Diagnostics

    NASA Astrophysics Data System (ADS)

    Wood, James T.

    1981-01-01

    In the summer of 1979 a task group was formed under ASTM Subcommittee C16.30 Section 7. The task group was asked to develop standard practices for the utilization of infrared (IR) imaging devices for the in-situ evaluation of building insulation systems. The group's work to date has concentrated on bounding the problem and prioritizing the needs for standard procedures. Most recently, the group has concentrated on a very specific utilization of infrared (IR) imaging as a qualitative instrument for building retrofit insulation inspections. White papers on equipment specifications and interpretation of imagery were generated as guides to writing the first draft of a standard practice document on this insulation retrofit inspection problem. The first draft describes the knowledge level of the inspector, the procedures for the inspection and the instrumentation required for various levels of diagnostics. Care has been taken to insure compatibility with ASHRAE Draft Standard 101P and to insure that the document will serve the user community as a guide to proper application of infrared in this infrared (IR) applications area.

  6. A Comparison of Six Different Diagnostic Procedures Used To Check Raw Quantitative Data for Outliers in a Generic Science Education Study.

    ERIC Educational Resources Information Center

    McGinnis, James Randy

    This generic science education study demonstrates the contrast of findings obtained through analyzing all the raw data as opposed to removing various combinations of identified potential outliers provided through the application of six diagnostic procedures. Outliers are defined as extreme data points with large residuals. It is argued that an…

  7. Diagnostic Tests and Procedures

    MedlinePlus

    ... your heart with a stethoscope. This is called auscultation, which means the study of heart sounds. Doctors ... diagnose some types of heart valve disease by listening to any abnormal heart sounds that they hear ...

  8. Cotton-based Diagnostic Devices

    PubMed Central

    Lin, Shang-Chi; Hsu, Min-Yen; Kuan, Chen-Meng; Wang, Hsi-Kai; Chang, Chia-Ling; Tseng, Fan-Gang; Cheng, Chao-Min

    2014-01-01

    A good diagnostic procedure avoids wasting medical resources, is easy to use, resists contamination, and provides accurate information quickly to allow for rapid follow-up therapies. We developed a novel diagnostic procedure using a “cotton-based diagnostic device” capable of real-time detection, i.e., in vitro diagnostics (IVD), which avoids reagent contamination problems common to existing biomedical devices and achieves the abovementioned goals of economy, efficiency, ease of use, and speed. Our research reinforces the advantages of an easy-to-use, highly accurate diagnostic device created from an inexpensive and readily available U.S. FDA-approved material (i.e., cotton as flow channel and chromatography paper as reaction zone) that adopts a standard calibration curve method in a buffer system (i.e., nitrite, BSA, urobilinogen and uric acid assays) to accurately obtain semi-quantitative information and limit the cross-contamination common to multiple-use tools. Our system, which specifically targets urinalysis diagnostics and employs a multiple biomarker approach, requires no electricity, no professional training, and is exceptionally portable for use in remote or home settings. This could be particularly useful in less industrialized areas. PMID:25393975

  9. Cerebrospinal Fluid IL-10 and IL-10/IL-6 as Accurate Diagnostic Biomarkers for Primary Central Nervous System Large B-cell Lymphoma

    PubMed Central

    Song, Yang; Zhang, Wei; Zhang, Li; Wu, Wei; Zhang, Yan; Han, Xiao; Yang, Chen; Zhang, Lu; Zhou, Daobin

    2016-01-01

    Early diagnosis of primary central nervous system lymphoma (PCNSL) represents a challenge, and cerebrospinal fluid (CSF) cytokines may be diagnostic biomarkers for PCNSL. We used an electrochemiluminescence immunoassay to measure interleukin (IL)-10, IL-6, IL-8 and tumor necrosis factor α (TNF-α) in the CSF of 22 B cell PCNSL patients and 80 patients with other CNS diseases. CSF IL-10 was significantly higher in PCNSL patients than in the control group (median 74.7 pg/ml vs < 5.0 pg/ml, P < 0.000). Using a CSF IL-10 cutoff value of 8.2 pg/ml, the diagnostic sensitivity and specificity were 95.5% and 96.1%, respectively (AUC, 0.957; 95% CI, 0.901–1.000). For a CSF IL-10/IL-6 cutoff value of 0.72, the sensitivity was 95.5%, and the specificity was 100.0% (AUC, 0.976; 95% CI, 0.929–1.000). An increased CSF IL-10 level at diagnosis and post-treatment was associated with poor Progression free survival (PFS) for patients with PCNSL (P = 0.0181 and P = 0.0002, respectively). A low diagnostic value for PCNSL was found with CSF IL-8 or TNF-α. In conclusion, increased CSF IL-10 was a reliable diagnostic biomarker for large B cell PCNSL, and an IL-10/IL-6 ratio facilitates differentiation from other conditions, especially a CNS infection. PMID:27924864

  10. A procedure for accurate calibration of the orientation of the three sensors in a vector magnetometer. [at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Mcpherron, R. L.

    1977-01-01

    Procedures are described for the calibration of a vector magnetometer of high absolute accuracy. It is assumed that the calibration will be performed in the magnetic test facility of Goddard Space Flight Center (GSFC). The first main section of the report describes the test equipment and facility calibrations required. The second presents procedures for calibrating individual sensors. The third discusses the calibration of the sensor assembly. In a final section recommendations are made to GSFC for modification of the test facility required to carry out the calibration procedures.

  11. Nuclear medicine practices in the 1950s through the mid-1970s and occupational radiation doses to technologists from diagnostic radioisotope procedures.

    PubMed

    Drozdovitch, Vladimir; Brill, Aaron B; Mettler, Fred A; Beckner, William M; Goldsmith, Stanley J; Gross, Milton D; Hays, Marguerite T; Kirchner, Peter T; Langan, James K; Reba, Richard C; Smith, Gary T; Bouville, André; Linet, Martha S; Melo, Dunstana R; Lee, Choonsik; Simon, Steven L

    2014-10-01

    Data on occupational radiation exposure from nuclear medicine procedures for the time period of the 1950s through the 1970s is important for retrospective health risk studies of medical personnel who conducted those activities. However, limited information is available on occupational exposure received by physicians and technologists who performed nuclear medicine procedures during those years. To better understand and characterize historical radiation exposures to technologists, the authors collected information on nuclear medicine practices in the 1950s, 1960s, and 1970s. To collect historical data needed to reconstruct doses to technologists, a focus group interview was held with experts who began using radioisotopes in medicine in the 1950s and the 1960s. Typical protocols and descriptions of clinical practices of diagnostic radioisotope procedures were defined by the focus group and were used to estimate occupational doses received by personnel, per nuclear medicine procedure, conducted in the 1950s to 1960s using radiopharmaceuticals available at that time. The radionuclide activities in the organs of the reference patient were calculated using the biokinetic models described in ICRP Publication 53. Air kerma rates as a function of distance from a reference patient were calculated by Monte Carlo radiation transport calculations using a hybrid computational phantom. Estimates of occupational doses to nuclear medicine technologists per procedure were found to vary from less than 0.01 μSv (thyroid scan with 1.85 MBq of administered I-iodide) to 0.4 μSv (brain scan with 26 MBq of Hg-chlormerodin). Occupational doses for the same diagnostic procedures starting in the mid-1960s but using Tc were also estimated. The doses estimated in this study show that the introduction of Tc resulted in an increase in occupational doses per procedure.

  12. Prenatal Diagnosis Procedures and Techniques to Obtain a Diagnostic Fetal Specimen or Tissue: Maternal and Fetal Risks and Benefits.

    PubMed

    Wilson, R Douglas; Gagnon, Alain; Audibert, François; Campagnolo, Carla; Carroll, June

    2015-07-01

    Objectif : Offrir aux fournisseurs de soins de maternité et à leurs patientes des lignes directrices factuelles contemporaines en ce qui concerne les services de counseling traitant des risques et des avantages maternels propres à la tenue des interventions diagnostiques prénatales orientées par échographie (et/ou des techniques permettant l’établissement d’un diagnostic génétique) nécessaires dans les cas où il a été établi pendant la période prénatale que la grossesse serait exposée à des risques, ainsi qu’en ce qui concerne la prise de décisions subséquentes quant à la prise en charge de la grossesse (questions abordant des aspects tels que le niveau du fournisseur de soins obstétricaux, la surveillance prénatale, le lieu où devraient se dérouler les soins et l’accouchement, et la décision de poursuivre ou d’interrompre la grossesse). La présente directive clinique se limite aux services de counseling traitant des risques et des avantages maternels, et aux décisions en matière de prise en charge de la grossesse pour les femmes qui nécessitent (ou qui envisagent) la mise en œuvre d’une intervention ou d’une technique effractive orientée par échographie aux fins de l’établissement d’un diagnostic prénatal. Population de patientes : Femmes enceintes identifiées, à la suite de la mise en œuvre de protocoles établis de dépistage prénatal (taux sériques maternels ± imagerie, résultats d’analyse de l’ADN acellulaire indiquant des risques élevés, résultats anormaux au moment de l’imagerie fœtale diagnostique ou antécédents familiaux de troubles héréditaires), comme étant exposées à un risque accru d’anomalie génétique fœtale. Ces femmes pourraient nécessiter ou demander des services de counseling au sujet des risques et des avantages pour la grossesse de la tenue d’une intervention effractive orientée par échographie visant à déterminer l’étiologie, le diagnostic, et/ou la

  13. Degree of Vertical Integration Between the Undergraduate Program and Clinical Internship with Respect to Lumbopelvic Diagnostic and Therapeutic Procedures Taught at the Canadian Memorial Chiropractic College

    PubMed Central

    Vermet, Shannon; McGinnis, Karen; Boodham, Melissa; Gleberzon, Brian J.

    2010-01-01

    Purpose: The objective of this study was to determine to what extent the diagnostic and therapeutic procedures taught in the undergraduate program used for patients with lumbopelvic conditions are expected to be utilized by students during their clinical internship program at Canadian Memorial Chiropractic College or are being used by the clinical faculty. Methods: A confidential survey was distributed to clinical faculty at the college. It consisted of a list of diagnostic and therapeutic procedures used for lumbopelvic conditions taught at that college. Clinicians were asked to indicate the frequency with which they performed or they required students to perform each item. Results: Seventeen of 23 clinicians responded. The following procedures were most likely required to be performed by clinicians: posture; ranges of motion; lower limb sensory, motor, and reflex testing; and core orthopedic tests. The following were less likely to be required to be performed: Waddell testing, Schober's test, Gillet tests, and abdominal palpation. Students were expected to perform (or clinicians performed) most of the mobilization (in particular, iliocostal, iliotransverse, and iliofemoral) and spinal manipulative therapies (in particular, the procedures referred to as the lumbar roll, lumbar pull/hook, and upper sacroiliac) taught at the college. Conclusion: This study suggests that there was considerable, but not complete, vertical integration between the undergraduate and clinical education program at this college. PMID:20480014

  14. [First guidelines of Croatian interest group in diagnosing and treating lower back and radicular pain using minimally invasive diagnostic and therapeutic procedures].

    PubMed

    Houra, Karlo; Perović, Darko; Kvesić, Drazen; Rados, Ivan; Kovac, Damir; Kapural, Leonardo

    2013-01-01

    Low back and radicular pain recently became a major public health problem. Medical expenses in general, and surgical procedures associated with overall care for the lower back pain are high and growing. Furthermore, these two chronic pain conditions are also leading causes for missed workdays. Degenerative changes of the intervertebral disc, facet joints, sacroiliac joint or disc herniation as described during imaging diagnostics may or may not be the cause of patients' lower back pain. Diagnostic blocks often precede further interventions in order to confirm or dispute a source of the lower back pain. Chronic lower back pain caused by painful intervertebral disc should be treated using biacuplasty. If the pain of the lumbar spine is caused by facet joints or sacroiliac joint, patient can be offered neuroablative procedures using radiofrequency. In cases where the low back and radicular pain are caused by the central and foraminal spinal stenosis patients are advised epidural steroid injections, unless claudications are present. Patients suffering from the chronic radicular pain may be treated with various nucleoplasty procedures or they may be offered percutaneous radiofrequent neuromodulation. The purpose of above advised procedures is to relieve patients' pain, allow optimal physical therapy, and improved functional capacity, consequently providing better quality of life.

  15. A diagnostic one-step real-time reverse transcription polymerase chain reaction method for accurate detection of influenza virus type A

    PubMed Central

    Behzadi, Mohammad Amin; Alborzi, Abdolvahab

    2016-01-01

    Introduction Influenza A is known as a public health concern worldwide. In this study, a novel one-step real-time reverse transcription polymerase chain reaction (rtRT-PCR) assay was designed and optimized for the detection of influenza A viruses. Material and methods The primers and probe were designed based on the analysis of 90 matrix nucleotide sequence data of influenza type A subtypes from the GenBank database of the National Center for Biotechnology Information (NCBI). The influenza virus A/Tehran/5652/2010 (H1N1 pdm09) was used as a reference. The rtRT-PCR assay was optimized, compared with that of the World Health Organization (WHO), and its analytical sensitivity, specificity and reproducibility were evaluated. In total, 64 nasopharyngeal swabs from patients with influenza-like illness (ILI) and 41 samples without ILI symptoms were tested for the virus, using conventional cell culture, direct immunofluorescence antibody (DFA) methods, and one-step rtRT-PCR with the designed primer set and probe and the WHO’s. Results The optimized assay results were similar to the WHO’s. The optimized assay results were similar to WHO’s, with non-significant differences for 10–103 copies of viral RNA/reaction (p > 0.05). It detected 10 copies of viral RNA/reaction with high reproducibility and no cross reactivity with other respiratory viruses. A specific cytopathic effect was observed in 6/64 (9.37%) of the ILI group using conventional culture and DFA staining methods; however, it was not seen in non-ILI. Also, the results of our assay and the WHO’s were similar to those of viral isolation and DFA staining. Conclusions Given the high specificity, sensitivity and reproducibility of this novel assay, it can serve as a reliable diagnostic tool for the detection of influenza A viruses in clinical specimens and lab experiments. PMID:27904520

  16. Assessment procedures for narcissistic personality disorder: a comparison of the personality diagnostic questionnaire-4 and best-estimate clinical judgments.

    PubMed

    Miller, Joshua D; Campbell, W Keith; Pilkonis, Paul A; Morse, Jennifer Q

    2008-12-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD) methodology. NPD scores demonstrated moderate convergence for the total scores but weak convergence for the individual criteria. The authors also examined the correlates created by each set of NPD scores using Cloninger's Temperament and Character Inventory (TCI). The NPD scores demonstrated areas of convergence (e.g., Cooperativeness, Self-directedness) and divergence (i.e., Harm Avoidance, Novelty Seeking) with these personality scores. These divergences may be due to the wording of certain items on the Personality Diagnostic Questionnaire-4 NPD scale, which may require rewriting if it is to provide an assessment that is more highly convergent with the Diagnostic and Statistical Manual of Mental Disorders NPD construct.

  17. Interrelation of Evaluation and Self-Evaluation in the Diagnostic Procedures to Assess Teachers' Readiness for Innovation

    ERIC Educational Resources Information Center

    Tyunnikov, Yurii S.

    2016-01-01

    The paper solves the problem of the relationship of external diagnosis and self-diagnosis of readiness of teachers to innovative activity. It highlights major disadvantages of measurement tools that are used to this process. The author demonstrates an alternative approach to harmonizing the diagnosis, based on a modular diagnostic model, general…

  18. Reliability and Validity of a Procedure To Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    Preliminary psychometric data assessing the reliability and validity of a method used to measure the diagnostic reasoning and problem-solving skills of predoctoral students in orthodontia are described. The measurement approach consisted of sets of patient demographic data and dental photos and x-rays, accompanied by a set of 33 multiple-choice…

  19. Assessment Procedures for Narcissistic Personality Disorder: A Comparison of the Personality Diagnostic Questionnaire-4 and Best-Estimate Clinical Judgments

    ERIC Educational Resources Information Center

    Miller, Joshua D.; Campbell, W. Keith; Pilkonis, Paul A.; Morse, Jennifer Q.

    2008-01-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD)…

  20. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  1. Frequency Scale Factors for Some Double-Hybrid Density Functional Theory Procedures: Accurate Thermochemical Components for High-Level Composite Protocols.

    PubMed

    Chan, Bun; Radom, Leo

    2016-08-09

    In the present study, we have obtained geometries and frequency scale factors for a number of double-hybrid density functional theory (DH-DFT) procedures. We have evaluated their performance for obtaining thermochemical quantities [zero-point vibrational energies (ZPVE) and thermal corrections for 298 K enthalpies (ΔH298) and 298 K entropies (S298)] to be used within high-level composite protocols (using the W2X procedure as a probe). We find that, in comparison with the previously prescribed protocol for optimization and frequency calculations (B3-LYP/cc-pVTZ+d), the use of contemporary DH-DFT methods such as DuT-D3 and DSD-type procedures leads to a slight overall improved performance compared with B3-LYP. A major strength of this approach, however, lies in the better robustness of the DH-DFT methods in that the largest deviations are notably smaller than those for B3-LYP. In general, the specific choices of the DH-DFT procedure and the associated basis set do not drastically change the performance. Nonetheless, we find that the DSD-PBE-P86/aug'-cc-pVTZ+d combination has a very slight edge over the others that we have examined, and we recommend its general use for geometry optimization and vibrational frequency calculations, in particular within high-level composite methods such as the higher-level members of the WnX series of protocols. The scale factors determined for DSD-PBE-P86/aug'-cc-pVTZ+d are 0.9830 (ZPVE), 0.9876 (ΔH298), and 0.9923 (S298).

  2. Spinal palpatory diagnostic procedures utilized by practitioners of spinal manipulation: annotated bibliography of content validity and reliability studies

    PubMed Central

    Seffinger, Michael; Adams, Alan; Najm, Wadie; Dickerson, Vivian; Mishra, Shiraz I; Reinsch, Sibylle; Murphy, Linda

    2003-01-01

    The diagnosis of spinal neuro-musculoskeletal dysfunction is a pre-requisite for application of spinal manual therapy. Different disciplines rely on palpatory procedures to establish this diagnosis and design treatment plans. Over the past 30 years, the osteopathic, chiropractic, physical therapy and allopathic professions have investigated the validity and reliability of spinal palpatory procedures. We explored the literature from all four disciplines looking for scientific papers studying the content validity and reliability of spinal palpatory procedures. Thirteen databases were searched for relevant papers between January 1966 and October 2001. An annotated bibliography of these articles is presented and organized by the type of test used.

  3. Entonox® inhalation to reduce pain in common diagnostic and therapeutic outpatient urological procedures: a review of the evidence

    PubMed Central

    Young, A; Ismail, M; Papatsoris, AG; Barua, JM; Calleary, JG; Masood, J

    2012-01-01

    INTRODUCTION Entonox® (50% nitrous oxide and 50% oxygen; BOC Healthcare, Manchester, UK) is an analgesic and anxiolytic agent that is used to successfully reduce pain and anxiety during dental, paediatric and emergency department procedures. In this article we review the application and efficacy of Entonox® in painful local anaesthesia urological procedures by performing a systematic review of the literature. METHODS A MEDLINE® search was performed using the terms ‘nitrous oxide’, ‘Entonox’, ‘prostate biopsy’, ‘flexible cystoscopy’ and ‘extracorporeal shock wave lithotripsy’. English language publications of randomised studies were identified and reviewed. RESULTS The search yielded five randomised studies that investigated the clinical efficacy of Entonox® as an analgesic for day case urological procedures. Three randomised controlled trials (RCTs) investigated Entonox® in transrectal ultrasonography guided prostate biopsy. All three reported significant reductions in pain score in the Entonox® versus control groups. One RCT reported significant reduction in pain during male flexible cystoscopy in the Entonox® group compared with the control group. One RCT, which examined the use of Entonox® during extracorporeal shock wave lithotripsy, found its use significantly decreased the pain score compared with the control group and this was comparable to intravenous pethidine. CONCLUSIONS Evidence from varied adult and paediatric procedures has shown Entonox® to be an effective, safe and patient acceptable form of analgesia. All published studies of its use in urological day case procedures have found it to significantly reduce procedural pain. There is huge potential to use this cheap, safe, effective analgesic in our current practice. PMID:22524905

  4. Diagnostic limitations to accurate diagnosis of cholera.

    PubMed

    Alam, Munirul; Hasan, Nur A; Sultana, Marzia; Nair, G Balakrish; Sadique, A; Faruque, A S G; Endtz, Hubert P; Sack, R B; Huq, A; Colwell, R R; Izumiya, Hidemasa; Morita, Masatomo; Watanabe, Haruo; Cravioto, Alejandro

    2010-11-01

    The treatment regimen for diarrhea depends greatly on correct diagnosis of its etiology. Recent diarrhea outbreaks in Bangladesh showed Vibrio cholerae to be the predominant cause, although more than 40% of the suspected cases failed to show cholera etiology by conventional culture methods (CMs). In the present study, suspected cholera stools collected from every 50th patient during an acute diarrheal outbreak were analyzed extensively using different microbiological and molecular tools to determine their etiology. Of 135 stools tested, 86 (64%) produced V. cholerae O1 by CMs, while 119 (88%) tested positive for V. cholerae O1 by rapid cholera dipstick (DS) assay; all but three samples positive for V. cholerae O1 by CMs were also positive for V. cholerae O1 by DS assay. Of 49 stools that lacked CM-based cholera etiology despite most being positive for V. cholerae O1 by DS assay, 25 (51%) had coccoid V. cholerae O1 cells as confirmed by direct fluorescent antibody (DFA) assay, 36 (73%) amplified primers for the genes wbe O1 and ctxA by multiplex-PCR (M-PCR), and 31 (63%) showed El Tor-specific lytic phage on plaque assay (PA). Each of these methods allowed the cholera etiology to be confirmed for 97% of the stool samples. The results suggest that suspected cholera stools that fail to show etiology by CMs during acute diarrhea outbreaks may be due to the inactivation of V. cholerae by in vivo vibriolytic action of the phage and/or nonculturability induced as a host response.

  5. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software.

    PubMed

    Poulet, Axel; Privat, Maud; Ponelle, Flora; Viala, Sandrine; Decousus, Stephanie; Perin, Axel; Lafarge, Laurence; Ollier, Marie; El Saghir, Nagi S; Uhrhammer, Nancy; Bignon, Yves-Jean; Bidet, Yannick

    Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm) of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts.

  6. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software

    PubMed Central

    Poulet, Axel; Privat, Maud; Viala, Sandrine; Decousus, Stephanie; Perin, Axel; Lafarge, Laurence; Ollier, Marie; El Saghir, Nagi S.

    2016-01-01

    Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm) of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts. PMID:27656653

  7. Characteristics of gastrointestinal stromal tumours, diagnostic procedure and therapeutic management and main directions of nursing practice in gastrointestinal stromal tumours

    PubMed Central

    Głuszek, Stanisław; Kozieł, Dorota

    2014-01-01

    Gastrointestinal stromal tumours (GIST) constitute a separate group of mesenchymal neoplasms of the gastrointestinal tract. They have been commonly recognized for a few years, they have created a new problem in medical practice. GIST are more often centred in the stomach. They equally affect female and male patients and occur mainly in patients older than 50 years of age. The clinical picture of the tumour is non-specific. Radical surgical treatment and molecularly targeted therapy with tyrosine kinase inhibitors are used in GIST treatment. Nursing practice with reference to GIST danger is connected with biopsychosocial interventions of perioperative, oncological and palliative procedures and involves the area of health education mainly oriented towards shaping preventive procedures which favour early disease detection and support therapy and recovery. PMID:25784835

  8. Recorded gonorrhoea rates in Denmark, 1900–2010: the impact of clinical testing activity and laboratory diagnostic procedures

    PubMed Central

    Lind, Inga; Hoffmann, Steen

    2015-01-01

    Objectives Assessment of the relations between recorded gonorrhoea rates and clinical testing activity and disposable diagnostic tests. Methods In Denmark, two sources of information on the epidemiology of gonorrhoea are available: (1) a mandatory clinical notification system (since 1867) comprising summary information about geographic distribution, season, age group and gender; in 1994, more detailed anonymous individualised epidemiological information was included; (2) a voluntary countrywide laboratory surveillance system for culture-confirmed cases (since 1957) comprising information about patient's age and gender, infected anatomical sites and medical setting attended. Results Both surveillance systems showed marked simultaneous changes in gonorrhoea rates, although periodically considerable under-reporting or under-diagnosing was demonstrated. The annual incidence of notified cases peaked in 1919 (474/100 000), in 1944 (583/100 000) and in 1972 (344/100 000). Since 1995, the incidence has been at a low endemic level (1.5–10/100 000) and the total male/female incidence ratios were from 3 to 7 times higher than previously recorded. Among approximately 2 million persons tested during 1974–1988 78 213 men and 63 143 women with culture-confirmed gonorrhoea were identified. During this period, pharyngeal sampling was performed in 36% of men and 25% of women with gonorrhoea; pharyngeal gonorrhoea was found in 10% and 16%, respectively; 40% and 30% of these patients had no concomitant urogenital gonorrhoea. Among men with gonorrhoea, 34% were sampled from the rectum; 9% had rectal gonorrhoea, among whom the rectum was the only infected site in 67%. Conclusions Crucial factors for case finding are clinical sampling tradition and appropriate laboratory diagnostic facilities. When case finding is insufficient, a reservoir of asymptomatic rectal or pharyngeal gonorrhoea remains unrecognised. PMID:26621510

  9. SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

    SciTech Connect

    Mahmood, U; Erdi, Y

    2015-06-15

    Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

  10. Follow-up study of persons who had iodine-131 and other diagnostic procedures during childhood and adolescence

    SciTech Connect

    Hamilton, P.M.; Chiacchierini, R.P.; Kaczmarek, R.G.

    1989-08-01

    A prospective study of 3,503 children and adolescents who received diagnostic doses of iodine-131 was conducted to evaluate the risk of radiation-induced thyroid neoplasia. The exposed group was followed for a total of 93,442 person-years. Thyroid doses received by the exposed group ranged from less than 10 rads to slightly more than 2,000 rads. The majority received less than 100 rads. A group of 2,594 children and adolescents who were not exposed to radioactive iodine comprised the control group for the study. Members of the control group were followed for a total of 66,797 person-years. An elevated risk of malignant thyroid tumors was observed in the exposed group. An increased risk of benign thyroid conditions was also noted in the exposed group. The results described above failed to fulfill the requirements for statistical significance because of the small number of cases but are suggestive of a radiation effect.

  11. An economic and rapid diagnostic procedure for the detection of salmonella/shigella using the polyvalent salmonella phage O-1.

    PubMed

    Fey, H; Bürgi, E; Margadant, A; Boller, E

    1978-01-01

    An easy, rapid and economic two-step procedure is described for the detection of Salmonella/Shigella. In the first step the susceptibility of suspected colonies for the phage O-1 of FELIX and CALLOW is tested. Positive cultures are serologically confirmed. The test is performed on Triple Sugar Iron Agar and lasts 4-6 hrs. Phage negative cultures which are lactose- and sucrose negative are tested for lysine decarboxylase and, if Shigella is possible (i.e. in human material on primary plates), for indol production and motility in a semisolid tryptophane agar. Of 22880 Salmonella straine 21977, i.e. 96.1% were phage-sensitive. Strains belonging to certain O-groups (OE) or species are lysed at a lower percentage. However, since they are lysine decarboxylase positive they are not lost and can be submitted to a serological examination.

  12. Population radiation dose from diagnostic nuclear medicine procedures in the Tehran population in 1999-2003: striking changes in only one decade.

    PubMed

    Tabeie, Faraj; Mohammadi, Hooshang; Asli, Isa Neshandar

    2013-02-01

    Use of unsealed radiopharmaceuticals in Iran's nuclear medicine centers has expanded rapidly in the last decade. As part of a nationwide survey, this study was undertaken to estimate the radiation risk due to the diagnostic nuclear medicine procedures performed in Tehran in 1999-2003. During the five years of the study, the data of 101,540 yearly examinations of diagnostic nuclear medicine were obtained for 34 (out of 40) active nuclear medicine centers in Tehran. The patients studied were aged 1 y, 5 y, 10 y, 15 y, and adults (>15 y). Compared to an earlier investigation in 1989 (which was published in 1995), striking changes were found to be occurring in the trends of nuclear medicine in Tehran in a matter of a decade. The frequency of cardiac examinations increased from less than 1% in 1989 to 43.2% (mean of 5 y) in 2003; thyroid examinations, with the relative frequency of higher than 80% in 1989, decreased to 26.7% in the current investigation (averaged for 2001); and the number of overall examinations per 1,000 population of Tehran increased from 1.9 in 1989 to 8.8 in this study (about fourfold). The decrease in relative frequency of thyroid examinations could be attributed to the lower referral policy (mainly by specialists), decreased incidence of goiter due to implementation of programs for iodine enrichment diets, introduction of fine needle aspiration (FNA), and sonography techniques for diagnosis of thyroid disease. The large increase in relative frequency of cardiac examinations could be due to the increase in the number of single photon emission computerized tomography (SPECT) systems in recent years as compared to 1989 in Tehran. The collective effective dose increased from 400 (person-Sv) in 1999 to 529 (person-Sv) in 2003, and the effective dose per capita increased from 34.80 μSv in 1999 to 44.06 μSv in 2003 (average, 35.60 μSv).

  13. The role of a labial salivary gland biopsy in the diagnostic procedure for Sjögren’s syndrome; a study of 94 cases

    PubMed Central

    van Stein-Callenfels, Dewi; Tan, Jonathan; Bloemena, Elisabeth; van Vugt, Richard M.; Voskuyl, Alexandre E.; Santana, Nathalie T.Y.

    2014-01-01

    Objectives: The purpose of the present study is to examine the role of the outcome of the labial salivary gland biopsy (LSGB) in the diagnostic procedure of patients suspected of suffering from Sjögren’s syndrome (SS). Material and Methods: In a retrospective study the result of histopathological assessment of 94 consecutively taken labial salivary gland biopsies has been examined. For the diagnosis of SS the American-European Consensus Group classification (AECG, 2002) have been used. The outcome of the assessment has been discussed in relation to a recently reported classification provided by the American College of Rheumatology (ACR, 2012). Results: In the 94 LSGBs support for a diagnosis of SS has been encountered in 24 out of 26 patients with SS. In the 68 patients with a negative diagnosis of SS only six positive LSGBs were observed. The sensitivity of the labial biopsy amounted 0.92; the specificity was 0.91, while the positive predictive value and the negative predictive value amounted 0.80 and 0.97 respectively. LSGBs taken by or on the request of the departments of Rheumatology or Internal Medicine had a significant higher yield compared to LSGBs taken in other clinical departments. Conclusions: The LSGB may play a role in the diagnostic procedure of Sjögren’s syndrome when using either the AECG classification or the ACR classification. A LSGB should preferably taken after counseling for the possible presence of SS by a department of Rheumatology or Internal Medicine since the yield of such biopsies is much higher than in patients who have not been counseled by these departments prior to the taking of a LSGB. When using the ACR classification, a positive serologic result and a positive ocular test make the taking of a LSGB redundant. Only in case of a negative serologic outcome or a negative result of the ocular test a LSGB is indicated. Since both the serologic test and the ocular test carry hardly any morbidity, these tests should, indeed, be

  14. Neurological Diagnostic Tests and Procedures

    MedlinePlus

    ... Thermography uses infrared sensing devices to measure small temperature changes between the two sides of the body ... called ultrasound scanning or sonography, uses high-frequency sound waves to obtain images inside the body. Neurosonography ( ...

  15. Surfactant-aided precipitation/on-pellet-digestion (SOD) procedure provides robust and rapid sample preparation for reproducible, accurate and sensitive LC/MS quantification of therapeutic protein in plasma and tissues.

    PubMed

    An, Bo; Zhang, Ming; Johnson, Robert W; Qu, Jun

    2015-04-07

    For targeted protein quantification by liquid chromatography mass spectrometry (LC/MS), an optimal approach for efficient, robust and hi-throughput sample preparation is critical, but often remains elusive. Here we describe a straightforward surfactant-aided-precipitation/on-pellet-digestion (SOD) strategy that provides effective sample cleanup and enables high and constant peptide yields in various matrices, allowing reproducible, accurate and sensitive protein quantification. This strategy was developed using quantification of monocolnocal antibody in tissues and plasma as the model system. Surfactant treatment before precipitation substantially increased peptide recovery and reproducibility from plasma/tissue, likely because surfactant permits extensive denaturation/reduction/alkylation of proteins and inactivation of endogenous protease inhibitors, and facilitates removal of matrix components. The subsequent precipitation procedure effectively eliminates the surfactant and nonprotein matrix components, and the thorough denaturation by both surfactant and precipitation enabled very rapid on-pellet-digestion (45 min at 37 °C) with high peptide recovery. The performance of SOD was systematically compared against in-solution-digestion, in-gel-digestion and filter-aided-sample-preparation (FASP) in plasma/tissues, and then examined in a full pharmacokinetic study in rats. SOD achieved the best peptide recovery (∼21.0-700% higher than the other three methods across various matrices), reproducibility (3.75-10.9%) and sensitivity (28-30 ng/g across plasma and tissue matrices), and its performance was independent of matrix types. Finally, in validation and pharmacokinetic studies in rats, SOD outperformed other methods and provided highly accurate and precise quantification in all plasma samples without using stable isotope labeled (SIL)-protein internal standard (I.S.). In summary, the SOD method has proven to be highly robust, efficient and rapid, making it readily

  16. The Evolution of Diagnostic and Interventional Ultrasound in Sports Medicine.

    PubMed

    Finnoff, Jonathan T

    2016-03-01

    Diagnostic and interventional ultrasound is a rapidly evolving field in sports medicine. The use of ultrasound has increased exponentially during the past decades. This imaging modality is appealing to sports medicine physicians because of its broad diagnostic and interventional capabilities. In sports medicine, the indications for diagnostic ultrasound extend well beyond the musculoskeletal realm to include other conditions such as ocular trauma, thoracoabdominal trauma, and cardiac morphology. Thus, the term "sports ultrasound" has been adopted as a more accurate representation of the broad and unique applications of ultrasound in this specialty. Ultrasound-guided procedures also have evolved from the commonly performed joint and tendon sheath injections to include ultrasound-guided surgical procedures. This article will discuss the evolution of diagnostic and interventional ultrasound in sports medicine using a case-based approach to highlight its many new applications.

  17. Sensitivity of Symptomatology Versus Diagnostic Procedures and Concentration of CEA and CA19–9 in the Early Detection of Colorectal Cancer

    PubMed Central

    Vukobrat-Bijedic, Zora; Husic-Selimovic, Azra; Bijedic, Nina; Mujkic, Admir; Sofic, Amela; Gogov, Bisera; Mehmedovic, Amila; Bjelogrlic, Ivana; Glavas, Sanjin; Djuran, Aleksandra

    2014-01-01

    important symptom. We can say that after the age of 74 years cancer of the rectum and sigmoid is more common in men and in women dominate sigma and other locations in the colon. In patients under the 70 years of age with short time of bleeding, cancer predominates in rectum. In patients younger than 63 years can be concluded that weight loss is greater than 8 kg follows rectal cancer. In patients with bleeding that lasted one month or more as classifier occurring the age and gender. Patients younger than 74 years have rectal cancer, while older than 73 years have cancer at other sites. In women these locations are sigma and rectum. Conclusion: Based on this study we can conclude that regardless of the technical advances in medicine must pay special attention to the symptoms that doctors will refer to the localization of the tumor, stenosis of the intestine and possibly metastasis. Key words: Colorectal cancer, diagnostic procedures, concentration of CEA and CA19-9. PMID:24825931

  18. Mild cognitive impairment (MCI) in medical practice: a critical review of the concept and new diagnostic procedure. Report of the MCI Working Group of the European Consortium on Alzheimer's Disease.

    PubMed

    Portet, F; Ousset, P J; Visser, P J; Frisoni, G B; Nobili, F; Scheltens, Ph; Vellas, B; Touchon, J

    2006-06-01

    Mild cognitive impairment (MCI) was proposed as a nosological entity referring to elderly people with mild cognitive deficit but no dementia. MCI is a heterogeneous clinical entity with multiple sources of heterogeneity. The concept of MCI was reviewed and a diagnostic procedure with three different stages was proposed by the European Consortium on Alzheimer's Disease Working Group on MCI. Firstly, MCI should correspond to cognitive complaints coming from the patients or their families; the reporting of a relative decline in cognitive functioning during the past year by a patient or informant; cognitive disorders as evidenced by clinical evaluation; absence of major repercussions on daily life; and absence of dementia. These criteria, similar to those defined during an international workshop in Stockholm, make it possible to identify an MCI syndrome, which is the first stage of the diagnostic procedure. Secondly, subtypes of MCI had to be recognised. Finally, the aetiopathogenic subtype could be identified. Identifying patients at a high risk for progression to dementia and establishing more specific and adapted therapeutic strategies at an early stage, together with more structured overall management, is made possible by the diagnostic procedure proposed.

  19. A comparison of the boomerang wire vascular access management system versus manual compression alone during percutaneous diagnostic and interventional cardiovascular procedures.

    PubMed

    Echeverria, Angela; Krajcer, Zvonimir

    2016-01-01

    Vascular closure devices allow for early sheath removal, allowing for earlier patient mobilization The Boomerang vascular access management system does not alter arterial integrity for future interventions Access site complications provide significant morbidity in diagnostic and therapeutic interventions.

  20. Prevalence and monthly distribution of head lice using two diagnostic procedures in several age groups in Uberlândia, State of Minas Gerais, Southeastern Brazil.

    PubMed

    Borges, Raquel; Silva, Juliana J; Rodrigues, Rosângela M; Mendes, Júlio

    2007-01-01

    Some epidemiological characteristics of head lice, Pediculus capitis, were studied using two procedures: cut hair analysis and head inspection. Higher prevalence rates were observed in the middle and at the end of the school terms. Both procedures indicated that children were the main reservoir for this type of pediculosis in Uberlândia.

  1. A Statistical Test of the Validity of Diagnostic Categories Used in Childhood Language Disorders: Implications for Assessment Procedures. Papers and Reports on Child Language Development, No. 4.

    ERIC Educational Resources Information Center

    Rosenthal, William S.; And Others

    This paper examines the validity of diagnostic categories frequently used to classify children with severe language disorders by determining the relationship of the categories to independently derived developmental, psychological, and medical variables. It is argued that the classification systems currently available too often fail to achieve the…

  2. Development of Dual TaqMan Based One-Step rRT-PCR Assay Panel for Rapid and Accurate Diagnostic Test of MERS-CoV: A Novel Human Coronavirus, Ahead of Hajj Pilgrimage

    PubMed Central

    Hashemzadeh, Mohammad Sadegh; Rasouli, Rahimeh; Zahraei, Bentolhoda; Izadi, Morteza; Tat, Mahdi; Saadat, Seyed Hassan; Najarasl, Mohammad; Khansari Nejad, Behzad; Dorostkar, Ruhollah

    2016-01-01

    Background Coronaviruses (CoVs) are large ribonucleic acid (RNA) viruses causing primarily respiratory disease in humans. A novel human coronavirus, subsequently named middle east respiratory syndrome coronavirus (MERS-CoV), was first reported in Saudi Arabia in September of 2012. With increasing numbers of infections and deaths from MERS-CoV, development of a rapid and reliable kit was crucial to prevent further spread of MERS-CoV. Objectives In this study, we present two real-time reverse-transcription polymerase chain reaction (rRT-PCR) assays for in-house rapid and sensitive diagnostic testing of MERS-CoV, detecting the regions upstream of the envelope gene (upE) and open reading frame (ORF) 1b, respectively, for initial screening and final confirmation of MERS-CoV infection, as recommended by the world health organization (WHO). Materials and Methods In this experimental study, acquiring patient samples was difficult; thus, according to WHO recommendations and standard protocols, we synthesized RNA sequences of upE and ORF1b genes as the template signatures and TaqMan based-diagnostic rRT-PCR assays were carried out using these synthetic genes for detection of MERS-CoV. In this research, we also inaugurated a cell-free system to transcribe these RNA sequences using the DNA templates synthesized. Results The upE and ORF1b based one-step rRT-PCR assays were optimized by testing several times via different synthetic RNAs, and validation results were highly successful. The sensitivity obtained for upE was fewer than ten copies of RNA template per reaction and for ORF1b was 50 or fewer copies per reaction. Conclusions This study showed that the developed rRT-PCR assays are rapid, reliable, reproducible, specific, sensitive, and simple tools for detection of MERS-CoV. Finally, a kit consisting of two assay signatures and controls was assembled, which can be distributed to public health laboratories in Iran to support international MERS-CoV surveillance and public

  3. Patient satisfaction and quality of care at four diagnostic imaging procedures: mammography, double-contrast barium enema, abdominal ultrasonography and vaginal ultrasonography.

    PubMed

    Loken, K; Steine, S; Laerum, E

    1999-01-01

    The objective of this study was to measure patient satisfaction and to investigate the practical implications of monitoring the quality of care at four radiology procedures. A survey was conducted immediately after the examinations in eight radiology departments: 550 patients attending for mammography, 110 for double-contrast barium enema (DCBE), 97 for abdominal ultrasonography and 90 for vaginal ultrasonography. Outcome measures were seven questionnaire scales: pain, emotional distress, information received, staff's punctuality and technical ability, facilities, and general satisfaction. Response rate was 87 %. Multivariate regression analysis showed significant differences between procedures on all scales (p < 0.001). Differences considered to be of practical importance, i. e. >/= 7 scale points, were detected on five of the scales. Mammography and DCBE caused the most pain, and vaginal US and DCBE caused the most distress. The US procedures entailed dissatisfaction with information about the procedures. The DCBE patients recorded dissatisfaction with the staff's lack of punctuality, and these and the mammography patients recorded dissatisfaction with the facilities. The findings indicate a potential for improving patients' experiences. Several aspects of care, i. e. pain management, attention to the patient's emotional concerns, explanation of procedures, punctuality and quality of the facilities, can be improved.

  4. Intelligent diagnostics systems

    NASA Technical Reports Server (NTRS)

    Mcquiston, Barbara M.; Dehoff, Ronald L.

    1992-01-01

    Intelligent systems have been applied to today's problems and could also be applied to space operations integrity. One of these systems is the XMAN tool designed for 'troubleshooting' jet engines. XMAN is the eXpert MAiNtenance tool developed to be an expert information analysis tool which stores trending and diagnostic data on Air Force engines. XMAN operates with a 'network topology' which follows a flow chart containing engine management information reports required by the governments technical order procedures. With XMAN technology, the user is able to identify engine problems by presenting the assertions of the fault isolation logic and attempting to satisfy individual assertions by referring to the databases created by an engine monitoring system. The troubleshooting process requires interaction between the technician and the computer to acquire new evidence form auxiliary maintenance tests corroboration of analytical results to accurately diagnose equipment malfunctions. This same technology will be required for systems which are functioning in space either with an onboard crew, or with an unmanned system. The technology and lessons learned developing this technology while suggesting definite applications for its use with developing space systems are addressed.

  5. SCAI/CCAS/SPA expert consensus statement for anesthesia and sedation practice: Recommendations for patients undergoing diagnostic and therapeutic procedures in the pediatric and congenital cardiac catheterization laboratory.

    PubMed

    Odegard, Kirsten C; Vincent, Robert; Baijal, Rahul; Daves, SuAnne; Gray, Robert; Javois, Alex; Love, Barry; Moore, Phil; Nykanen, David; Riegger, Lori; Walker, Scott G; Wilson, Elizabeth C

    2016-11-15

    Current practice of sedation and anesthesia for patients undergoing pediatric congenital cardiac catheterization laboratory (PCCCL) procedures is known to vary among institutions, a multi-society expert panel with representatives from the Congenital Heart Disease Council of the Society for Cardiovascular Angiography and Interventions (SCAI), the Society for Pediatric Anesthesia (SPA) and the Congenital Cardiac Anesthesia Society (CCAS) was convened to evaluate the types of sedation and personnel necessary for procedures performed in the PCCCL. The goal of this panel was to provide practitioners and institutions performing these procedures with guidance consistent with national standards and to provide clinicians and institutions with consensus-based recommendations and the supporting references to encourage their application in quality improvement programs. Recommendations can neither encompass all clinical circumstances nor replace the judgment of individual clinicians in the management of each patient. The science of medicine is rooted in evidence, and the art of medicine is based on the application of this evidence to the individual patient. This expert consensus statement has adhered to these principles for optimal management of patients requiring sedation and anesthesia. What follows are recommendations for patient monitoring in the PCCCL regardless of whether minimal or no sedation is being used or general anesthesia is being provided by an anesthesiologist. © 2016 Wiley Periodicals Inc.

  6. [Optimisation of diagnostics and differential diagnostics disseminated pulmonary tuberculosis].

    PubMed

    Demikhova, O V; Karpina, N L; Lepekha, L N; Bagirov, M A; Amansakhedov, R B

    2012-01-01

    One of the reasons of dramatic situation with tuberculosis in Russia is untimely diagnostics of tuberculosis. The aim of the study was to identify the causes of diagnostic mistakes when we deal with disseminated pulmonary tuberculosis at current stage and to modernize the diagnostic process. The analysis of the diagnostic activity of the consultative diagnostic center of Central Tuberculosis Research Institute of Russian Academy Medical Sciences for 2011 was performed with special attention on the results of the survey of 505 patients with pulmonary dissemination. The frequency of discrepancies of disseminated pulmonary tuberculosis diagnostics was 96.1%. Based on the studies carried out the main causes diagnostic mistakes in patients with disseminated pulmonary tuberculosis were determined. New directions of improving of tuberculosis diagnostics were developed: overall high-technology examination of patient, adherence to the diagnostic procedure, developed by consultative diagnostic center of Central Tuberculosis Research Institute (CTRI), timely performing fiber-optic bronchoscopy with complex biopsy and diagnostic surgery procedures, further training of primary health care doctors. Implementation of proposed activities will significantly (by 3-5 times) reduce the time for diagnostics of respiratory system disease.

  7. Establishment of an on-site diagnostic procedure for detection of orf virus from oral lesions of Japanese serows (Capricornis crispus) by loop-mediated isothermal amplification

    PubMed Central

    INOSHIMA, Yasuo; TAKASU, Masaki; ISHIGURO, Naotaka

    2016-01-01

    Orf virus infection has been prevalent continuously in the population of wild Japanese serows (Capricornis crispus), goat-like grazing cloven-hoofed mammal species that live mainly in mountainous areas of Japan. Currently, definitive diagnosis of infection requires time-consuming laboratory work. To diagnose rapidly on-site, we developed a field-friendly procedure for the detection of orf virus from oral cavity lesions. DNA was extracted from goat saliva spiked with orf virus as a proxy for Japanese serows by a commercial kit without the use of electricity, and the quality of the extracted DNA was evaluated by conventional polymerase chain reaction (PCR). Extracted DNA was amenable to DNA amplification, the same as when extracted in a laboratory. Next, to find optimal conditions for DNA amplification by loop-mediated isothermal amplification (LAMP), Bst and Csa DNA polymerases and 3 colorimetric indicators for visual diagnosis, hydroxy naphthol blue (HNB), malachite green and D-QUICK, were compared using a portable cordless incubator. The combination of Bst or Csa DNA polymerase with HNB was found to be easiest for visual diagnosis by the naked eye, and viral DNA was successfully amplified from all orf virus strains used. These results suggest that the procedure established here can work completely on-site and can be useful for definitive diagnosis and differentiation of orf virus infection in Japanese serows in remote mountainous areas. PMID:27628591

  8. Current Trends and Healthcare Resource Usage in the Hospital Treatment of Primary Malignant Brain Tumor in Japan: A National Survey Using the Diagnostic Procedure Combination Database (J-ASPECT Study-Brain Tumor)

    PubMed Central

    YOSHIMOTO, Koji; KADA, Akiko; KUGA, Daisuke; HATAE, Ryusuke; MURATA, Hideki; AKAGI, Yojiro; NISHIMURA, Kunihiro; KUROGI, Ryota; NISHIMURA, Ataru; HATA, Nobuhiro; MIZOGUCHI, Masahiro; SAYAMA, Tetsuro; IIHARA, Koji

    2016-01-01

    We conducted this study to clarify the current trends and healthcare resource usage in the treatment of inpatients with primary malignant brain tumors. The Diagnostic Procedure Combination (DPC) data of all inpatients treated between 2013 and 2014 in the 370 core and branch hospitals enrolled in the Japanese Neurosurgical Society training program were collected. DPC is a discharge abstract and administrative claims database of inpatients. We assessed 6,142 primary, malignant brain tumor patients. Patient information, diagnostic information, treatment procedure, and healthcare resource usage were analyzed. Chemotherapy was the most frequent treatment (27% of cases), followed by surgery (13%) and surgery + chemo-radiotherapy (11%). Temozolomide (TMZ), the most frequently used chemotherapeutic drug, was administered to 1,236 patients. Concomitant TMZ and radiotherapy was administered to 816 patients, and was performed according to the Stupp regimen in many cases. The mean length of hospital stay (LOS) was 16 days, and the mean medical cost was 1,077,690 yen. The average medical cost of TMZ-only treatment was 1,138,620 yen whilst it was 4,424,300 yen in concomitant TMZ patients. The LOS was significantly shorter in high-volume than in low-volume hospitals, and the medical cost was higher in hospitals treating 21–50 patients compared to those treating 1–10 patients. However, the direct medical cost of TMZ treatment was the same across different volume hospitals. This is the first report of current trends and healthcare resource usage in the treatment of primary malignant brain tumor inpatients in the TMZ era in Japan. PMID:27680329

  9. Current Trends and Healthcare Resource Usage in the Hospital Treatment of Primary Malignant Brain Tumor in Japan: A National Survey Using the Diagnostic Procedure Combination Database (J-ASPECT Study-Brain Tumor).

    PubMed

    Yoshimoto, Koji; Kada, Akiko; Kuga, Daisuke; Hatae, Ryusuke; Murata, Hideki; Akagi, Yojiro; Nishimura, Kunihiro; Kurogi, Ryota; Nishimura, Ataru; Hata, Nobuhiro; Mizoguchi, Masahiro; Sayama, Tetsuro; Iihara, Koji

    2016-11-15

    We conducted this study to clarify the current trends and healthcare resource usage in the treatment of inpatients with primary malignant brain tumors. The Diagnostic Procedure Combination (DPC) data of all inpatients treated between 2013 and 2014 in the 370 core and branch hospitals enrolled in the Japanese Neurosurgical Society training program were collected. DPC is a discharge abstract and administrative claims database of inpatients. We assessed 6,142 primary, malignant brain tumor patients. Patient information, diagnostic information, treatment procedure, and healthcare resource usage were analyzed. Chemotherapy was the most frequent treatment (27% of cases), followed by surgery (13%) and surgery + chemo-radiotherapy (11%). Temozolomide (TMZ), the most frequently used chemotherapeutic drug, was administered to 1,236 patients. Concomitant TMZ and radiotherapy was administered to 816 patients, and was performed according to the Stupp regimen in many cases. The mean length of hospital stay (LOS) was 16 days, and the mean medical cost was 1,077,690 yen. The average medical cost of TMZ-only treatment was 1,138,620 yen whilst it was 4,424,300 yen in concomitant TMZ patients. The LOS was significantly shorter in high-volume than in low-volume hospitals, and the medical cost was higher in hospitals treating 21-50 patients compared to those treating 1-10 patients. However, the direct medical cost of TMZ treatment was the same across different volume hospitals. This is the first report of current trends and healthcare resource usage in the treatment of primary malignant brain tumor inpatients in the TMZ era in Japan.

  10. Attendance at Cervical Cancer Screening and Use of Diagnostic and Therapeutic Procedures on the Uterine Cervix Assessed from Individual Health Insurance Data (Belgium, 2002-2006)

    PubMed Central

    Arbyn, Marc; Fabri, Valérie; Temmerman, Marleen; Simoens, Cindy

    2014-01-01

    Objective To assess the coverage for cervical cancer screening as well as the use of cervical cytology, colposcopy and other diagnostic and therapeutic interventions on the uterine cervix in Belgium, using individual health insurance data. Methods The Intermutualistic Agency compiled a database containing 14 million records from reimbursement claims for Pap smears, colposcopies, cervical biopsies and surgery, performed between 2002 and 2006. Cervical cancer screening coverage was defined as the proportion of women aged 25–64 that had a Pap smear within the last 3 years. Results Cervical cancer screening coverage was 61% at national level, for the target population of women between 25 and 64 years old, in the period 2004–2006. Differences between the 3 regions were small, but varied more substantially between provinces. Coverage was 70% for 25–34 year old women, 67% for those aged 35–39 years, and decreased to 44% in the age group of 60–64 years. The median screening interval was 13 months. The screening coverage varied substantially by social category: 40% and 64%, in women categorised as beneficiary or not-beneficiary of increased reimbursement from social insurance, respectively. In the 3-year period 2004–2006, 3.2 million screen tests were done in the target group consisting of 2.8 million women. However, only 1.7 million women got one or more smears and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman in three years of time. Colposcopy was excessively used (number of Pap smears over colposcopies = 3.2). The proportion of women with a history of conisation or hysterectomy, before the age of 65, was 7% and 19%, respectively. Conclusion The screening coverage increased slightly from 59% in 2000 to 61% in 2006. The screening intensity remained at a high level, and the number of cytological examinations was theoretically sufficient to cover more than the whole target population. PMID:24690620

  11. Integrated diagnostics

    NASA Technical Reports Server (NTRS)

    Hunthausen, Roger J.

    1988-01-01

    Recently completed projects in which advanced diagnostic concepts were explored and/or demonstrated are summarized. The projects begin with the design of integrated diagnostics for the Army's new gas turbine engines, and advance to the application of integrated diagnostics to other aircraft subsystems. Finally, a recent project is discussed which ties together subsystem fault monitoring and diagnostics with a more complete picture of flight domain knowledge.

  12. On numerically accurate finite element

    NASA Technical Reports Server (NTRS)

    Nagtegaal, J. C.; Parks, D. M.; Rice, J. R.

    1974-01-01

    A general criterion for testing a mesh with topologically similar repeat units is given, and the analysis shows that only a few conventional element types and arrangements are, or can be made suitable for computations in the fully plastic range. Further, a new variational principle, which can easily and simply be incorporated into an existing finite element program, is presented. This allows accurate computations to be made even for element designs that would not normally be suitable. Numerical results are given for three plane strain problems, namely pure bending of a beam, a thick-walled tube under pressure, and a deep double edge cracked tensile specimen. The effects of various element designs and of the new variational procedure are illustrated. Elastic-plastic computation at finite strain are discussed.

  13. Accurate Finite Difference Algorithms

    NASA Technical Reports Server (NTRS)

    Goodrich, John W.

    1996-01-01

    Two families of finite difference algorithms for computational aeroacoustics are presented and compared. All of the algorithms are single step explicit methods, they have the same order of accuracy in both space and time, with examples up to eleventh order, and they have multidimensional extensions. One of the algorithm families has spectral like high resolution. Propagation with high order and high resolution algorithms can produce accurate results after O(10(exp 6)) periods of propagation with eight grid points per wavelength.

  14. Accurate monotone cubic interpolation

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1991-01-01

    Monotone piecewise cubic interpolants are simple and effective. They are generally third-order accurate, except near strict local extrema where accuracy degenerates to second-order due to the monotonicity constraint. Algorithms for piecewise cubic interpolants, which preserve monotonicity as well as uniform third and fourth-order accuracy are presented. The gain of accuracy is obtained by relaxing the monotonicity constraint in a geometric framework in which the median function plays a crucial role.

  15. ROM Plus®: accurate point-of-care detection of ruptured fetal membranes

    PubMed Central

    McQuivey, Ross W; Block, Jon E

    2016-01-01

    Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article. PMID:27274316

  16. ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes.

    PubMed

    McQuivey, Ross W; Block, Jon E

    2016-01-01

    Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article.

  17. Diagnostic hematology of reptiles.

    PubMed

    Stacy, Nicole I; Alleman, A Rick; Sayler, Katherine A

    2011-03-01

    The hematologic evaluation of reptiles is an indispensable diagnostic tool in exotic veterinary practice. The diversity of reptile species, their characteristic physiologic features, and effects of intrinsic and extrinsic factors present unique challenges for accurate interpretation of the hemogram. Combining the clinical presentation with hematologic findings provides valuable information in the diagnosis and monitoring of disease and helps guide the clinician toward therapy and further diagnostic testing. This article outlines the normal and pathologic morphology of blood cells of reptile species. The specific comparative aspects of reptiles are emphasized, and structural and functional abnormalities in the reptilian hemogram are described.

  18. Total cholesterol performance of Abell–Levy–Brodie–Kendall reference measurement procedure: Certification of Japanese in-vitro diagnostic assay manufacturers through CDC’s Cholesterol Reference Method Laboratory Network☆

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Kiyama, Masahiko; Yokoyama, Shinji; Kayamori, Yuzo; Koyama, Isao; Nishimura, Kunihiro; Nakai, Michikazu; Dasti, Mahnaz; Vesper, Hubert W.; Teramoto, Tamio; Miyamoto, Yoshihiro

    2015-01-01

    Background Accurate measurement of total cholesterol (TC) is important for cardiovascular disease risk management. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform Abell–Levy–Brodie–Kendall (AK) reference measurement procedure (RMP) for TC as a secondary reference method, and implement Certification Protocol for Manufacturers. Japanese CRMLN laboratory at Osaka performed the AK RMP for 22 years, and conducted TC certification for reagent/calibrator/instrument systems of six Japanese manufacturers every 2 years for 16 years. Osaka TC performance was examined and compared to CDC’s reference values. Methods AK RMP involved sample hydrolysis, cholesterol extraction, and determination of cholesterol levels by spectrophotometry. The Certification Protocol for Manufacturers includes comparison with AK RMP using at least 40 fresh specimens. Demonstration of average bias ≤3% and total coefficient of variation ≤3% qualified an analytical system for certification. Results In the AK RMP used in the Osaka CRMLN laboratory, the regression equation for measuring TC was y (Osaka) = 1.000x (CDC) + 0.032 (n = 619, R2 = 1.000). Six Japanese manufacturers had allowable performance for certification. Conclusions The AK RMP for TC measurement was accurate, precise, and stable for 22 years. Six Japanese manufacturers were certified for 16 years. PMID:25818239

  19. Accurate quantum chemical calculations

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Langhoff, Stephen R.; Taylor, Peter R.

    1989-01-01

    An important goal of quantum chemical calculations is to provide an understanding of chemical bonding and molecular electronic structure. A second goal, the prediction of energy differences to chemical accuracy, has been much harder to attain. First, the computational resources required to achieve such accuracy are very large, and second, it is not straightforward to demonstrate that an apparently accurate result, in terms of agreement with experiment, does not result from a cancellation of errors. Recent advances in electronic structure methodology, coupled with the power of vector supercomputers, have made it possible to solve a number of electronic structure problems exactly using the full configuration interaction (FCI) method within a subspace of the complete Hilbert space. These exact results can be used to benchmark approximate techniques that are applicable to a wider range of chemical and physical problems. The methodology of many-electron quantum chemistry is reviewed. Methods are considered in detail for performing FCI calculations. The application of FCI methods to several three-electron problems in molecular physics are discussed. A number of benchmark applications of FCI wave functions are described. Atomic basis sets and the development of improved methods for handling very large basis sets are discussed: these are then applied to a number of chemical and spectroscopic problems; to transition metals; and to problems involving potential energy surfaces. Although the experiences described give considerable grounds for optimism about the general ability to perform accurate calculations, there are several problems that have proved less tractable, at least with current computer resources, and these and possible solutions are discussed.

  20. Endodontic diagnostic terminology update.

    PubMed

    McClannahan, Scott B; Baisden, Michael K; Bowles, Walter R

    2011-01-01

    Determination of the etiology of the patient's chief complaint and a correct diagnosis are paramount prior to a recommendation of endodontic therapy. Reproduction of the patient's chief complaint is critical. If the chief complaint cannot be reproduced, consider consultation with or referral to an endodontist or orofacial pain specialist. The diagnostic terminology presented in this update provides for a more accurate description and communication of the health or pathological conditions of both pulpal and apical tissues. This information is summarized in Table I.

  1. Beamlet laser diagnostics

    SciTech Connect

    Burkhart, S.C.; Behrendt, W.C.; Smith, I.

    1996-06-01

    Beamlet is instrumented extensively to monitor the performance of the overall laser system and many of its subsystems. Beam diagnostics, installed in key locations, are used to fully characterize the beam during its propagation through the multipass cavity and the laser`s output section. This article describes the diagnostics stations located on Beamlet and discusses the design, calibration, and performance of the Beamlet calorimeters. The authors used Nova`s diagnostics packages to develop the Beamlet design to determine beam energy, spatial profile, temporal profile, and other beam parameters. Technologic improvements within the last several years in controls, charge-coupled device (CCD) cameras, and fast oscilloscopes have allowed the authors to obtain more accurate measurements on the Beamlet laser system. They briefly cover some of these techniques, including a description of their LabVIEW based data acquisition system.

  2. Diagnostic Coding for Epilepsy.

    PubMed

    Williams, Korwyn; Nuwer, Marc R; Buchhalter, Jeffrey R

    2016-02-01

    Accurate coding is an important function of neurologic practice. This contribution to Continuum is part of an ongoing series that presents helpful coding information along with examples related to the issue topic. Tips for diagnosis coding, Evaluation and Management coding, procedure coding, or a combination are presented, depending on which is most applicable to the subject area of the issue.

  3. BIOACCESSIBILITY TESTS ACCURATELY ESTIMATE ...

    EPA Pesticide Factsheets

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from five Pb-contaminated Superfund sites had relative bioavailabilities from 33%-63%, with a mean of about 50%. Treatment of two of the soils with P significantly reduced the bioavailability of Pb. The bioaccessibility of the Pb in the test soils was then measured in six in vitro tests and regressed on bioavailability. They were: the “Relative Bioavailability Leaching Procedure” (RBALP) at pH 1.5, the same test conducted at pH 2.5, the “Ohio State University In vitro Gastrointestinal” method (OSU IVG), the “Urban Soil Bioaccessible Lead Test”, the modified “Physiologically Based Extraction Test” and the “Waterfowl Physiologically Based Extraction Test.” All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the RBALP pH 2.5 and OSU IVG tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter 24%, or present as Pb sulfate 18%. Ad

  4. Accurate diagnosis of Giardia spp and proper fecal examination procedures.

    PubMed

    Dryden, M W; Payne, P A; Smith, V

    2006-01-01

    A series of investigations evaluated the ability of different testing methods - a swing-head centrifugation technique using two flotation solutions (1.18-specific gravity zinc sulfate and 1.27-specific gravity Sheather's sugar solution), a passive commercial flotation technique, and the SNAP Giardia Test Kit from IDEXX Laboratories - to identify Giardia-positive dogs and recover the eggs of other intestinal parasites. It was determined that the SNAP Giardia test can improve a practice's ability to identify Giardia-infected dogs. Because of its higher specific gravity, the sugar solution was better for recovering heavy parasite eggs, such as Taenia spp, and thus is the flotation solution of choice when conducting routine centrifugation fecal examinations.

  5. Faster and More Accurate Transport Procedures for HZETRN

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Blattnig, Steve R.; Badavi, Francis F.

    2010-01-01

    Several aspects of code verification are examined for HZETRN. First, a detailed derivation of the numerical marching algorithms is given. Next, a new numerical method for light particle transport is presented, and improvements to the heavy ion transport algorithm are discussed. A summary of various coding errors is also given, and the impact of these errors on exposure quantities is shown. Finally, a coupled convergence study is conducted. From this study, it is shown that past efforts in quantifying the numerical error in HZETRN were hindered by single precision calculations and computational resources. It is also determined that almost all of the discretization error in HZETRN is caused by charged target fragments below 50 AMeV. Total discretization errors are given for the old and new algorithms, and the improved accuracy of the new numerical methods is demonstrated. Run time comparisons are given for three applications in which HZETRN is commonly used. The new algorithms are found to be almost 100 times faster for solar particle event simulations and almost 10 times faster for galactic cosmic ray simulations.

  6. Faster and more accurate transport procedures for HZETRN

    SciTech Connect

    Slaba, T.C.; Blattnig, S.R.; Badavi, F.F.

    2010-12-10

    The deterministic transport code HZETRN was developed for research scientists and design engineers studying the effects of space radiation on astronauts and instrumentation protected by various shielding materials and structures. In this work, several aspects of code verification are examined. First, a detailed derivation of the light particle (A {<=} 4) and heavy ion (A > 4) numerical marching algorithms used in HZETRN is given. References are given for components of the derivation that already exist in the literature, and discussions are given for details that may have been absent in the past. The present paper provides a complete description of the numerical methods currently used in the code and is identified as a key component of the verification process. Next, a new numerical method for light particle transport is presented, and improvements to the heavy ion transport algorithm are discussed. A summary of round-off error is also given, and the impact of this error on previously predicted exposure quantities is shown. Finally, a coupled convergence study is conducted by refining the discretization parameters (step-size and energy grid-size). From this study, it is shown that past efforts in quantifying the numerical error in HZETRN were hindered by single precision calculations and computational resources. It is determined that almost all of the discretization error in HZETRN is caused by the use of discretization parameters that violate a numerical convergence criterion related to charged target fragments below 50 AMeV. Total discretization errors are given for the old and new algorithms to 100 g/cm{sup 2} in aluminum and water, and the improved accuracy of the new numerical methods is demonstrated. Run time comparisons between the old and new algorithms are given for one, two, and three layer slabs of 100 g/cm{sup 2} of aluminum, polyethylene, and water. The new algorithms are found to be almost 100 times faster for solar particle event simulations and almost 10 times faster for galactic cosmic ray simulations.

  7. Accurate spectral color measurements

    NASA Astrophysics Data System (ADS)

    Hiltunen, Jouni; Jaeaeskelaeinen, Timo; Parkkinen, Jussi P. S.

    1999-08-01

    Surface color measurement is of importance in a very wide range of industrial applications including paint, paper, printing, photography, textiles, plastics and so on. For a demanding color measurements spectral approach is often needed. One can measure a color spectrum with a spectrophotometer using calibrated standard samples as a reference. Because it is impossible to define absolute color values of a sample, we always work with approximations. The human eye can perceive color difference as small as 0.5 CIELAB units and thus distinguish millions of colors. This 0.5 unit difference should be a goal for the precise color measurements. This limit is not a problem if we only want to measure the color difference of two samples, but if we want to know in a same time exact color coordinate values accuracy problems arise. The values of two instruments can be astonishingly different. The accuracy of the instrument used in color measurement may depend on various errors such as photometric non-linearity, wavelength error, integrating sphere dark level error, integrating sphere error in both specular included and specular excluded modes. Thus the correction formulas should be used to get more accurate results. Another question is how many channels i.e. wavelengths we are using to measure a spectrum. It is obvious that the sampling interval should be short to get more precise results. Furthermore, the result we get is always compromise of measuring time, conditions and cost. Sometimes we have to use portable syste or the shape and the size of samples makes it impossible to use sensitive equipment. In this study a small set of calibrated color tiles measured with the Perkin Elmer Lamda 18 and the Minolta CM-2002 spectrophotometers are compared. In the paper we explain the typical error sources of spectral color measurements, and show which are the accuracy demands a good colorimeter should have.

  8. Recent advances in salivary cancer diagnostics enabled by biosensors and bioelectronics.

    PubMed

    Mishra, Saswat; Saadat, Darius; Kwon, Ohjin; Lee, Yongkuk; Choi, Woon-Seop; Kim, Jong-Hoon; Yeo, Woon-Hong

    2016-07-15

    There is a high demand for a non-invasive, rapid, and highly accurate tool for disease diagnostics. Recently, saliva based diagnostics for the detection of specific biomarkers has drawn significant attention since the sample extraction is simple, cost-effective, and precise. Compared to blood, saliva contains a similar variety of DNA, RNA, proteins, metabolites, and microbiota that can be compiled into a multiplex of cancer detection markers. The salivary diagnostic method holds great potential for early-stage cancer diagnostics without any complicated and expensive procedures. Here, we review various cancer biomarkers in saliva and compare the biomarkers efficacy with traditional diagnostics and state-of-the-art bioelectronics. We summarize biomarkers in four major groups: genomics, transcriptomics, proteomics, and metabolomics/microbiota. Representative bioelectronic systems for each group are summarized based on various stages of a cancer. Systematic study of oxidative stress establishes the relationship between macromolecules and cancer biomarkers in saliva. We also introduce the most recent examples of salivary diagnostic electronics based on nanotechnologies that can offer rapid, yet highly accurate detection of biomarkers. A concluding section highlights areas of opportunity in the further development and applications of these technologies.

  9. [Thalassaemia diagnostics].

    PubMed

    Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P

    2014-01-01

    The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.

  10. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    PubMed

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics.

  11. Astrovirus Diagnostics

    PubMed Central

    Pérot, Philippe; Lecuit, Marc; Eloit, Marc

    2017-01-01

    Various methods exist to detect an astrovirus infection. Current methods include electron microscopy (EM), cell culture, immunoassays, polymerase chain reaction (PCR) and various other molecular approaches that can be applied in the context of diagnostic or in surveillance studies. With the advent of metagenomics, novel human astrovirus (HAstV) strains have been found in immunocompromised individuals in association with central nervous system (CNS) infections. This work reviews the past and current methods for astrovirus detection and their uses in both research laboratories and for medical diagnostic purposes. PMID:28085120

  12. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  13. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  14. DIAGNOSTICS OF BNL ERL

    SciTech Connect

    POZDEYEV,E.; BEN-ZVI, I.; CAMERON, P.; GASSNER, D.; KAYRAN, D.; ET AL.

    2007-06-25

    The ERL Prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high-intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high-current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This paper outlines requirements on the ERL diagnostics and describes its setup and modes of operation.

  15. Diagnostic imaging in pediatric emergencies

    SciTech Connect

    Heller, R.M.; Coulam, C.M.; Allen, J.H.; Fleischer, A.; Lee, G.S.; Kirchner, S.G.; James A.E. Jr.

    1980-07-01

    Evaluation of pediatric emergencies by diagnostic imaging technics can involve both invasive and noninvasive procedures. Nuclear medicine, conventional radiography, ultrasound, computerized axial tomography, and xeroradiography are the major nonangiographic diagnostic technics available for patient evaluation. We will emphasize the use of computerized axial tomography, nuclear medicine, xeroradiography, and ultrasound in the evaluation of emergencies in the pediatric age group. Since the radiologist is the primary consultant with regard to diagnostic imaging, his knowledge of these modulities can greatly influence patient care and clinical results.

  16. Knowledge based jet engine diagnostics

    NASA Technical Reports Server (NTRS)

    Jellison, Timothy G.; Dehoff, Ronald L.

    1987-01-01

    A fielded expert system automates equipment fault isolation and recommends corrective maintenance action for Air Force jet engines. The knowledge based diagnostics tool was developed as an expert system interface to the Comprehensive Engine Management System, Increment IV (CEMS IV), the standard Air Force base level maintenance decision support system. XMAM (trademark), the Expert Maintenance Tool, automates procedures for troubleshooting equipment faults, provides a facility for interactive user training, and fits within a diagnostics information feedback loop to improve the troubleshooting and equipment maintenance processes. The application of expert diagnostics to the Air Force A-10A aircraft TF-34 engine equipped with the Turbine Engine Monitoring System (TEMS) is presented.

  17. Follow-up of Wilms tumor: comparison of CT with other imaging procedures

    SciTech Connect

    Brasch, R.C.; Randel, S.B.; Gould, R.G.

    1981-11-01

    In a retrospective review, computed tomography (CT) was compared to a ''routine'' combination of other diagnostic imaging procedures used for follow-up evaluations of 13 children being treated for Wilms tumor. The examined variables were diagnostic accuracy, expense, and duration of examination. Results from 13 patients indicated that CT most accurately answers diagnostic queries pertinent to follow-up evaluation of Wilms tumors: the presence and extent of bilateral renal tumors, local recurrence, contralateral renal hypertrophy, and metastasis to liver or lungs. For diagnosing pulmonary metastases, CT was superior to conventional chest radiography both in sensitivity (4/4 vs. 2/4) and specificity (9/9 vs. 6/9). In depiction of liver metastases, CT (3/3) was superior to liver scintigraphy (2/3). The extent of bilateral Wilms tumors was better defined by CT than by urography. In no instances were the alternative diagnostic imaging studies found to be more accurate than CT for the detection of recurrent tumor. Average cost for a CT examination ($344) is considerably less than the cost for a routine combination of the other imaging studies ($594). Examination time and diagnostic radiation doses are also reduced using CT. Pending larger comparison studies, CT is recommended as the primary diagnostic method for follow-up evaluation of patients with Wilms tumor.

  18. Unmet Diagnostic Needs in Infectious Disease

    PubMed Central

    Blaschke, Anne J.; Hersh, Adam L.; Beekmann, Susan E.; Ince, Dilek; Polgreen, Philip M.; Hanson, Kimberly E.

    2014-01-01

    Accurate diagnosis is critical to providing appropriate care in infectious diseases. New technologies for infectious disease diagnostics are emerging, but gaps remain in test development and availability. The Emerging Infections Network surveyed Infectious Diseases physicians to assess unmet diagnostic needs. Responses reflected the urgent need to identify drug-resistant infections and highlighted the potential for early diagnosis to improve antibiotic stewardship. Information gained from this survey can help inform recommendations for new diagnostic test development in the future. PMID:25456043

  19. FEL-accelerator related diagnostics

    SciTech Connect

    Kevin Jordan; David Douglas; Stephen V. Benson; Pavel Evtuschenko

    2007-08-02

    Free Electron Lasers (FEL) present a unique set of beam parameters to the diagnostics suite. The FEL requires characterization of the full six dimensional phase space of the electron beam at the wiggler and accurate alignment of the electron beam to the optical mode of the laser. In addition to the FEL requirements on the diagnostics suite, the Jefferson Lab FEL is operated as an Energy Recovered Linac (ERL) which imposes additional requirements on the diagnostics. The ERL aspect of the Jefferson Lab FEL requires that diagnostics operate over a unique dynamic range and operate with simultaneous transport of the accelerated and energy recovered beams. This talk will present how these challenges are addressed at the Jefferson Lab FEL.

  20. Rapid diagnostic tests for malaria.

    PubMed

    Visser, Theodoor; Daily, Jennifer; Hotte, Nora; Dolkart, Caitlin; Cunningham, Jane; Yadav, Prashant

    2015-12-01

    Maintaining quality, competitiveness and innovation in global health technology is a constant challenge for manufacturers, while affordability, access and equity are challenges for governments and international agencies. In this paper we discuss these issues with reference to rapid diagnostic tests for malaria. Strategies to control and eliminate malaria depend on early and accurate diagnosis. Rapid diagnostic tests for malaria require little training and equipment and can be performed by non-specialists in remote settings. Use of these tests has expanded significantly over the last few years, following recommendations to test all suspected malaria cases before treatment and the implementation of an evaluation programme to assess the performance of the malaria rapid diagnostic tests. Despite these gains, challenges exist that, if not addressed, could jeopardize the progress made to date. We discuss recent developments in rapid diagnostic tests for malaria, highlight some of the challenges and provide suggestions to address them.

  1. SDQ: discriminative validity and diagnostic potential

    PubMed Central

    Silva, Thaysa B. F.; Osório, Flávia L.; Loureiro, Sonia R.

    2015-01-01

    The Strengths and Difficulties Questionnaire (SDQ) was designed to screen for behavioral problems in youths based on cutoff points that favor the instrument's diagnostic sensitivity. The present study aimed to analyze the discriminative validity of the SDQ to identify behavioral difficulties and prosocial resources in school-age children compared with the diagnostic data collected by the corresponding sections of the Development and Well-being Assessment (DAWBA). In addition, new cutoff points that value specificity were defined for the SDQ scales, exploring its diagnostic potential. This study was conducted in Brazil and assessed a community convenience sample that consisted of 120 children aged 6–12 years who were not under psychological/psychiatric treatment. The mothers of the participants also completed a sociodemographic questionnaire. Descriptive statistics were used to clinically characterize the sample. A ROC curve was used to assess the discriminant validity of the SDQ, and new cutoff points were established to maximize the instrument's specificity. The new cutoff points enabled a significant increase in specificity without a significant loss of sensitivity, which favors approaches based on measures of screening and diagnosis yet does not damage the instrument's screening capacity. The following increases were observed: 100% for the depressive disorder scale (cutoff point = 7), 95.1% for the generalized anxiety disorder scale (cutoff point = 7), 46.6% for the conduct disorder scale (cutoff point = 6), 19.2% for the hyperactive disorder scale (cutoff point = 8), and 27.6% for the antisocial personality disorder scale (cutoff point = 6). A cutoff point of 8 was applied to the prosocial behavior scale, which exhibited a 62.1% increase in specificity. The use of more specific cutoff points generated more accurate results and favored SDQ's use, particularly in contexts of care that require more precise and faster procedures for identification of problems

  2. Accurate Evaluation of Quantum Integrals

    NASA Technical Reports Server (NTRS)

    Galant, D. C.; Goorvitch, D.; Witteborn, Fred C. (Technical Monitor)

    1995-01-01

    Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schrodinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

  3. Calibration issues for neutron diagnostics

    SciTech Connect

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-12-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next.

  4. Salivary diagnostics

    PubMed Central

    Lee, J.M.; Garon, E.; Wong, D.T.

    2010-01-01

    The ability to monitor health status, disease onset and progression, and treatment outcome through non-invasive means is a most desirable goal in the health care promotion and delivery. There are three prerequisites to materialize this goal: specific biomarkers associated with a health or disease state; a non-invasive approach to detect and monitor the biomarkers; and the technologies to discriminate the biomarkers. A national initiative catalyzed by the National Institute of Dental & Craniofacial Research (NIDCR) has created a roadmap to achieve these goals through the use of oral fluids as the diagnostic medium to scrutinize the health and/or disease status of individuals. Progress has shown this is an ideal opportunity to bridge state of the art saliva-based biosensors, optimized to disease discriminatory salivary biomarkers, for diagnostic applications. Oral fluid being the ‘mirror of body’ is a perfect medium to be explored for health and disease surveillance. The translational applications and opportunities are enormous. PMID:19627522

  5. High Frequency QRS ECG Accurately Detects Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian; Poulin, Gregory; Moser, Daniel R.; Delgado, Reynolds

    2005-01-01

    High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing

  6. PROcess Based Diagnostics PROBE

    NASA Technical Reports Server (NTRS)

    Clune, T.; Schmidt, G.; Kuo, K.; Bauer, M.; Oloso, H.

    2013-01-01

    Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

  7. Rotorcraft Diagnostics

    NASA Technical Reports Server (NTRS)

    Haste, Deepak; Azam, Mohammad; Ghoshal, Sudipto; Monte, James

    2012-01-01

    Health management (HM) in any engineering systems requires adequate understanding about the system s functioning; a sufficient amount of monitored data; the capability to extract, analyze, and collate information; and the capability to combine understanding and information for HM-related estimation and decision-making. Rotorcraft systems are, in general, highly complex. Obtaining adequate understanding about functioning of such systems is quite difficult, because of the proprietary (restricted access) nature of their designs and dynamic models. Development of an EIM (exact inverse map) solution for rotorcraft requires a process that can overcome the abovementioned difficulties and maximally utilize monitored information for HM facilitation via employing advanced analytic techniques. The goal was to develop a versatile HM solution for rotorcraft for facilitation of the Condition Based Maintenance Plus (CBM+) capabilities. The effort was geared towards developing analytic and reasoning techniques, and proving the ability to embed the required capabilities on a rotorcraft platform, paving the way for implementing the solution on an aircraft-level system for consolidation and reporting. The solution for rotorcraft can he used offboard or embedded directly onto a rotorcraft system. The envisioned solution utilizes available monitored and archived data for real-time fault detection and identification, failure precursor identification, and offline fault detection and diagnostics, health condition forecasting, optimal guided troubleshooting, and maintenance decision support. A variant of the onboard version is a self-contained hardware and software (HW+SW) package that can be embedded on rotorcraft systems. The HM solution comprises components that gather/ingest data and information, perform information/feature extraction, analyze information in conjunction with the dependency/diagnostic model of the target system, facilitate optimal guided troubleshooting, and offer

  8. Whipple Procedure

    MedlinePlus

    ... Blog Patient Education Pancreas News Basics of Pancreatic Cancer FAQs The Pancreas Types of Tumors Causes Hereditary Factors Known Risk Factors Symptoms and Side Effects Screening Questions Palliative Care Diagnosis Diagnostic Tests Metastasis Staging Treatment and Care Surgical ...

  9. Training for advanced endoscopic procedures.

    PubMed

    Feurer, Matthew E; Draganov, Peter V

    2016-06-01

    Advanced endoscopy has evolved from diagnostic ERCP to an ever-increasing array of therapeutic procedures including EUS with FNA, ablative therapies, deep enteroscopy, luminal stenting, endoscopic suturing and endoscopic mucosal resection among others. As these procedures have become increasingly more complex, the risk of potential complications has also risen. Training in advanced endoscopy involves more than obtaining a minimum number of therapeutic procedures. The means of assessing a trainee's competence level and ability to practice independently continues to be a matter of debate. The use of quality indicators to measure performance levels may be beneficial as more advanced techniques and procedures become available.

  10. In-line sensor for accurate rf power measurements

    NASA Astrophysics Data System (ADS)

    Gahan, D.; Hopkins, M. B.

    2005-10-01

    An in-line sensor has been constructed with 50Ω characteristic impedance to accurately measure rf power dissipated in a matched or unmatched load with a view to being implemented as a rf discharge diagnostic. The physical construction and calibration technique are presented. The design is a wide band, hybrid directional coupler/current-voltage sensor suitable for fundamental and harmonic power measurements. A comparison with a standard wattmeter using dummy load impedances shows that this in-line sensor is significantly more accurate in mismatched conditions.

  11. In-line sensor for accurate rf power measurements

    SciTech Connect

    Gahan, D.; Hopkins, M.B.

    2005-10-15

    An in-line sensor has been constructed with 50 {omega} characteristic impedance to accurately measure rf power dissipated in a matched or unmatched load with a view to being implemented as a rf discharge diagnostic. The physical construction and calibration technique are presented. The design is a wide band, hybrid directional coupler/current-voltage sensor suitable for fundamental and harmonic power measurements. A comparison with a standard wattmeter using dummy load impedances shows that this in-line sensor is significantly more accurate in mismatched conditions.

  12. Diagnostic Potential of Pulsed Arterial Spin Labeling in Alzheimer's Disease

    PubMed Central

    Trebeschi, Stefano; Riederer, Isabelle; Preibisch, Christine; Bohn, Karl P.; Förster, Stefan; Alexopoulos, Panagiotis; Zimmer, Claus; Kirschke, Jan S.; Valentinitsch, Alexander

    2016-01-01

    Alzheimers disease (AD) is the most common cause of dementia. Although the underlying pathology is still not completely understood, several diagnostic methods are available. Frequently, the most accurate methods are also the most invasive. The present work investigates the diagnostic potential of Pulsed Arterial Spin Labeling (PASL) for AD: a non-invasive, MRI-based technique for the quantification of regional cerebral blood flow (rCBF). In particular, we propose a pilot computer aided diagnostic (CAD) procedure able to discriminate between healthy and diseased subjects, and at the same time, providing visual informative results. This method encompasses the creation of a healthy model, the computation of a voxel-wise likelihood function as comparison between the healthy model and the subject under examination, and the correction of the likelihood function via prior distributions. The discriminant analysis is carried out to maximize the accuracy of the classification. The algorithm has been trained on a dataset of 81 subjects and achieved a sensitivity of 0.750 and a specificity of 0.875. Moreover, in accordance with the current pathological knowledge, the parietal lobe, and limbic system are shown to be the main discriminant factors. PMID:27147946

  13. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  14. Instrumentation and diagnostics

    SciTech Connect

    Nakaishi, C.V.; Bedick, R.C.

    1990-12-01

    This Technology Status Report describes research and accomplishments for the Instrumentation and Diagnostics (I D) Projects within the Advanced Research and Technology Development (AR TD) Program of the United States Department of Energy (DOE) Office of Fossil Energy (FE). Process understanding and control can be improved through the development of advanced instrumentation and diagnostics. The thrust of the I D Projects is to further develop existing measurement and control techniques for application to advanced coal-based technologies. Project highlights are: an inductively coupled plasma (ICP) instrument has been developed to analyze trace elements in gasification and combustion process streams. An in situ two-color Mie scattering technique with LSS can simultaneously measure the size, velocity, and elemental composition of coal particles during combustion. A high-temperature, fluorescence thermometry technique has accurately measured gas temperatures during field testing in combustion and gasification environments. Expert systems have been developed to improve the control of advanced coal-based processes. Capacitance flowmeters were developed to determine the mass flowrate, solid volume fraction, and particle velocities of coal slurries. 32 refs., 9 figs.

  15. Micron Accurate Absolute Ranging System: Range Extension

    NASA Technical Reports Server (NTRS)

    Smalley, Larry L.; Smith, Kely L.

    1999-01-01

    The purpose of this research is to investigate Fresnel diffraction as a means of obtaining absolute distance measurements with micron or greater accuracy. It is believed that such a system would prove useful to the Next Generation Space Telescope (NGST) as a non-intrusive, non-contact measuring system for use with secondary concentrator station-keeping systems. The present research attempts to validate past experiments and develop ways to apply the phenomena of Fresnel diffraction to micron accurate measurement. This report discusses past research on the phenomena, and the basis of the use Fresnel diffraction distance metrology. The apparatus used in the recent investigations, experimental procedures used, preliminary results are discussed in detail. Continued research and equipment requirements on the extension of the effective range of the Fresnel diffraction systems is also described.

  16. Diagnostic testing managed by hematopathology specialty and other laboratories: costs and patient diagnostic outcomes

    PubMed Central

    2014-01-01

    Background Successful management of patients with hematologic malignancies depends upon accurate and timely diagnosis, which frequently requires integration and interpretation of multiple tests. Our retrospective analysis compared diagnostic uncertainty, resource utilization, and costs for patients with diagnostic bone marrow (BM) tests managed by commercial laboratories. Methods Patients with BM biopsies and suspected hematologic cancer/condition were identified from claims (2005–2011) within a large US health plan (coverage ≥6 pre- and ≥3-months post-biopsy). Cohorts defined by laboratories performing BM morphologic assessment/directing testing sequence: Genoptix (GX, specialty hematology-testing laboratory), large commercial laboratories (LL), other laboratories (OL). One-year post-biopsy changes in diagnosis or treatments, tests performed, and diagnostic/treatment medical costs (measured as per-patient-per-month [PPPM]) were examined. Results The study population included 1,387 GX, 4,162 LL, and 19,115 OL patients with suspected hematologic malignancy/disease and BM morphology assessment. GX had lower diagnostic uncertainty measured between 2 time periods by diagnostic stability (no conditions the same; 6.16% GX, 8.04% LL, 9.73% OL; p < 0.001) and changes (≥1 condition different; 7.88% GX, 11.19% LL, and 14.08% OL; p < 0.001), fewer repeat BM biopsies, and fewer chemotherapy changes (30-days and 60-days post-initiation). One-year PPPM costs adjusted for patient characteristics differences were $8,202 GX, $7,711 LL, and $10,302 OL (p < 0.05); adjusted PPPM costs (excluding testing period) were $6,019 GX, $6,649 LL, and $7,801 OL (p < 0.05). Conclusions Our data suggests that a hematopathology specialty laboratory may result in earlier final diagnosis, fewer subsequent diagnosis changes, reduced need for follow-on testing requiring repeat biopsy procedures, and may result in lower downstream healthcare costs. Further evaluations using

  17. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic

  18. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection. (a) All scales used to determine the net weight of meat...

  19. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection. (a) All scales used to determine the net weight of meat...

  20. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection. (a) All scales used to determine the net weight of meat...

  1. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection. (a) All scales used to determine the net weight of meat...

  2. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection. (a) All scales used to determine the net weight of meat...

  3. Diagnostics in Japan's microgravity experiments

    NASA Technical Reports Server (NTRS)

    Kadota, Toshikazu

    1995-01-01

    The achievement of the combustion research under microgravity depends substantially on the availability of diagnostic systems. The non-intrusive diagnostic systems are potentially applicable for providing the accurate, realistic and detailed information on momentum, mass and energy transport, complex gas phase chemistry, and phase change in the combustion field under microgravity. The non-intrusive nature of optical instruments is essential to the measurement of combustion process under microgravity which is very nervous to any perturbation. However, the implementation of the non-intrusive combustion diagnostic systems under microgravity is accompanied by several constraints. Usually, a very limited space is only available for constructing a highly sophisticated system which is so sensitive that it is easily affected by the magnitude of the gravitational force, vibration and heterogeneous field of temperature and density of the environments. The system should be properly adjusted prior to the experiment. Generally, it is quite difficult to tune the instruments during measurements. The programmed sequence of operation should also be provided. Extensive effort has been toward the development of non-intrusive diagnostic systems available for the combustion experiments under microgravity. This paper aims to describe the current art and the future strategy on the non-intrusive diagnostic systems potentially applicable to the combustion experiments under microgravity in Japan.

  4. New diagnostic tools in schistosomiasis.

    PubMed

    Utzinger, J; Becker, S L; van Lieshout, L; van Dam, G J; Knopp, S

    2015-06-01

    Schistosomiasis is a water-based parasitic disease that affects over 250 million people. Control efforts have long been in vain, which is one reason why schistosomiasis is considered a neglected tropical disease. However, since the new millennium, interventions against schistosomiasis are escalating. The initial impetus stems from a 2001 World Health Assembly resolution, urging member states to scale-up deworming of school-aged children with the anthelminthic drug praziquantel. Because praziquantel is safe, efficacious and inexpensive when delivered through the school platform, diagnosis before drug intervention was deemed unnecessary and not cost-effective. Hence, there was little interest in research and development of novel diagnostic tools. With the recent publication of the World Health Organization (WHO) Roadmap to overcome the impact of neglected tropical diseases in 2020, we have entered a new era. Elimination of schistosomiasis has become the buzzword and this has important ramifications for diagnostic tools. Indeed, measuring progress towards the WHO Roadmap and whether local elimination has been achieved requires highly accurate diagnostic assays. Here, we introduce target product profiles for diagnostic tools that are required for different stages of a schistosomiasis control programme. We provide an update of the latest developments in schistosomiasis diagnosis, including microscopic techniques, rapid diagnostic tests for antigen detection, polymerase chain reaction (PCR) assays and proxy markers for morbidity assessments. Particular emphasis is placed on challenges and solutions for new technologies to enter clinical practice.

  5. Distribution of certain drug products by registered blood establishments and comprehensive hemophilia diagnostic treatment centers that qualify as health care entities; Prescription Drug Marketing Act of 1987; Prescription Drug Amendments of 1992; policies, requirements and administrative procedures. Final rule.

    PubMed

    2008-10-09

    The Food and Drug Administration (FDA) is amending its regulations to allow certain registered blood establishments and comprehensive hemophilia diagnostic treatment centers that are also health care entities to distribute certain drug products. The final rule amends limited provisions of the regulations implementing the Prescription Drug Marketing Act of 1987 (PDMA), as modified by the Prescription Drug Amendments of 1992 (PDA). These regulations, among other things, restrict the sale, purchase, or trade of, or the offer to sell, purchase, or trade, prescription drugs purchased by hospitals and other health care entities.

  6. Diagnostic modalities.

    PubMed

    Elstob, Alison; Gonsalves, Michael; Patel, Uday

    2016-12-01

    The incidental detection of small renal masses on imaging undertaken to evaluate unrelated symptoms or conditions is an increasingly common occurrence. Accurate imaging characterisation is fundamental to determining optimum patient management. The goals of imaging small renal masses include determining whether a lesion is solid or cystic, if there are signs of biological aggressiveness and whether the lesion is likely benign or malignant. The current imaging practices and the evidence supporting the use of different imaging modalities for the characterisation of small renal masses are discussed. CT remains the primary imaging modality and is able to classify most masses into surgical or non-surgical lesions. MRI and contrast enhanced ultrasound are most often employed to problem solve in lesions deemed indeterminate on contrast enhanced CT or for patients in which CECT is contraindicated. Percutaneous biopsy should be considered in lesions that remain indeterminate after initial imaging investigations. Given the central role of imaging in the management of small renal masses, all multidisciplinary team members involved in renal cancer care should have an understanding of the performance of the different imaging modalities.

  7. Hysteroscopy as a minimally invasive surgery, a good substitute for invasive gynecological procedures

    PubMed Central

    Abdollahi Fard, Seddigheh; Mostafa Gharabaghi, Parvin; Montazeri, Farnaz; Mashrabi, Omid

    2012-01-01

    Background: Hysteroscopy is a safe and high efficient procedure so it is changing to a widespread procedure in dealing with many gynecologic and obstetrical conditions. Objective: This study aimed to evaluate the diagnostic and therapeutical efficiency of hysteroscopy in managing the common conditions including abnormal uterine bleeding, abortion and infertility. Materials and Methods: This was a descriptive cross-sectional study to compare hysteroscopy as a minimally invasive approach with conventional laparatomy and hysterectomy or repair of mulerian anomalies and watch the uterine cavity for intrauterine pathology in cases of infertility. Overall 277 women underwent hysteroscopy were evaluated in three groups: with AUB 226 cases, with infertility 34 cases and with recurrent abortions with septate uterus17 cases. The overall success rate was recorded and analyzed after six months in order of indication of hysteroscopy Results: Hysteroscopy as sole diagnostic procedure in 16.5, 8.8 and 14.3%of AUB, infertility and abortion cases, respectively. In AUB cases, curettage, myomectomy, polypectomy and hysterectomy were the main diagnostic-therapeutical approaches along with hysteroscopy. In infertiles, myomectomy, polypectomy were the main diagnostic-therapeutical approaches In abortion group, laparoscopy guided, septum resection adhessiolysis , curettage and myomectomy were the main aproach. There was not any major complication. The diagnostic-therapeutically measures accompanying with the hysteroscopy were successful in 73.5% of the bleeding group and 33.3% of the infertility group in follow-up period. Conclusion: Based on our results, hysteroscopy is a safe, accurate and highly-efficient procedure in managing women with abnormal uterine bleeding, recurrent abortion due to septate uterus PMID:25246901

  8. Appropriate use of diagnostic imaging

    SciTech Connect

    Palmer, P.E.S.; Cockshott, W.P.

    1984-11-16

    This article discusses ways in which more appropriate use can be made of roentgenography with a resulting decrease in radiation doses to the patient population. The authors recommend that fewer films be made and that traditional roentgenography be replaced with endoscopy, ultrasound, computerized tomography, or angiography where appropriate. They also recommend that medical schools and medical subspecialty groups study the World Health Organization document which provides indications for diagnostic imaging, the choice of procedure and the limitations of each.

  9. Open lung biopsy: a safe, reliable and accurate method for diagnosis in diffuse lung disease.

    PubMed

    Shah, S S; Tsang, V; Goldstraw, P

    1992-01-01

    The ideal method for obtaining lung tissue for diagnosis should provide high diagnostic yield with low morbidity and mortality. We reviewed all 432 patients (mean age 55 years) who underwent an open lung biopsy at this hospital over a 10-year period. Twenty-four patients (5.5%) were immunocompromised. One hundred and twenty-five patients were on steroid therapy at the time of operation. Open lung biopsy provided a firm diagnosis in 410 cases overall (94.9%) and in 20 out of 24 patients in the immunocompromised group (83.3%). The commonest diagnosis was cryptogenic fibrosing alveolitis (173 patients). Twenty-two patients (5.1%) suffered complications following the procedure: wound infection 11 patients, pneumothorax 9 patients and haemothorax 1 patient. Thirteen patients (3.0%) died following open lung biopsy, but in only 1 patient was the death attributable to the procedure itself. We conclude that open lung biopsy is an accurate and safe method for establishing a diagnosis in diffuse lung disease with a high yield and minimal risk.

  10. Procedural learning and dyslexia.

    PubMed

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken.

  11. Procedural sedation analgesia

    PubMed Central

    Sheta, Saad A

    2010-01-01

    The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades.Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA). The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interventions. The goals of PSA in four different multidisciplinary practices namely; emergency, dentistry, radiology and gastrointestinal endoscopy are discussed in this review article. Some procedures are painful, others painless. Therefore, goals of PSA vary widely. Sedation management can range from minimal sedation, to the extent of minimal anesthesia. Procedural sedation in emergency department (ED) usually requires combinations of multiple agents to reach desired effects of analgesia plus anxiolysis. However, in dental practice, moderate sedation analgesia (known to the dentists as conscious sedation) is usually what is required. It is usually most effective with the combined use of local anesthesia. The mainstay of success for painless imaging is absolute immobility. Immobility can be achieved by deep sedation or minimal anesthesia. On the other hand, moderate sedation, deep sedation, minimal anesthesia and conventional general anesthesia can be all utilized for management of gastrointestinal endoscopy. PMID:20668560

  12. Chronic Meningitis: Simplifying a Diagnostic Challenge.

    PubMed

    Baldwin, Kelly; Whiting, Chris

    2016-03-01

    Chronic meningitis can be a diagnostic dilemma for even the most experienced clinician. Many times, the differential diagnosis is broad and encompasses autoimmune, neoplastic, and infectious etiologies. This review will focus on a general approach to chronic meningitis to simplify the diagnostic challenges many clinicians face. The article will also review the most common etiologies of chronic meningitis in some detail including clinical presentation, diagnostic testing, treatment, and outcomes. By using a case-based approach, we will focus on the key elements of clinical presentation and laboratory analysis that will yield the most rapid and accurate diagnosis in these complicated cases.

  13. Rapid infectious diseases diagnostics using Smartphones

    PubMed Central

    Bates, Matthew

    2015-01-01

    The “Smartphone” is an almost universal possession in high-income populations, and is rapidly becoming so in lower-income regions, particularly among urban populations, and serves social networking and a quest for information and knowledge. The field of infectious disease diagnostics is at a potential watershed moment, with the essential building blocks for the development of diagnostic assays being ever more available and affordable, which is leading to creative innovative approaches to developing much-needed accurate and simple point-of-care (POC) diagnostic tools for high disease burden, low-income settings. We review the importance and implications of a paper published in Science Translational Medicine on the development of a smartphone-powered and -controlled multiplex immunological assay that tests for HIV and syphilis simultaneously. This is reviewed in the context of other prototype smartphone-enabled/assisted diagnostic devices, and how such developments might shape the future of the POC diagnostics field. PMID:26488011

  14. Toxoplasma gondii: history and diagnostic test development.

    PubMed

    Wyrosdick, Heidi M; Schaefer, John J

    2015-12-01

    Toxoplasma gondii is a protozoa that causes toxoplasmosis in people and other animals. It is considered one of the most common parasitic infections in the world due to its impressive range of hosts, widespread environmental contamination and the diverse means by which animals can be infected. Despite its ubiquity and numerous ongoing research efforts into both its basic biology and clinical management, many aspects of diagnosis and management of this disease are poorly understood. The range of diagnostic options that is available for veterinary diagnostic investigators are notably more limited than those available to medical diagnosticians, making accurate interpretation of each test result critical. The current review joins other reviews on the parasite with a particular emphasis on the history and continued development of diagnostic tests that are useful for veterinary diagnostic investigations. An understanding of the strengths and shortcomings of current diagnostic techniques will assist veterinary and public health officials in formulating effective treatment and control strategies in diverse animal populations.

  15. Plasmodium falciparum parasites lacking histidine-rich protein 2 and 3: a review and recommendations for accurate reporting

    PubMed Central

    2014-01-01

    Malaria rapid diagnostic tests (RDTs) play a critical role in malaria case management, surveillance and case investigations. Test performance is largely determined by design and quality characteristics, such as detection sensitivity, specificity, and thermal stability. However, parasite characteristics such as variable or absent expression of antigens targeted by RDTs can also affect RDT performance. Plasmodium falciparum parasites lacking the PfHRP2 protein, the most common target antigen for detection of P. falciparum, have been reported in some regions. Therefore, accurately mapping the presence and prevalence of P. falciparum parasites lacking pfhrp2 would be an important step so that RDTs targeting alternative antigens, or microscopy, can be preferentially selected for use in such regions. Herein the available evidence and molecular basis for identifying malaria parasites lacking PfHRP2 is reviewed, and a set of recommended procedures to apply for future investigations for parasites lacking PfHRP2, is proposed. PMID:25052298

  16. Accurate simulation of optical properties in dyes.

    PubMed

    Jacquemin, Denis; Perpète, Eric A; Ciofini, Ilaria; Adamo, Carlo

    2009-02-17

    Since Antiquity, humans have produced and commercialized dyes. To this day, extraction of natural dyes often requires lengthy and costly procedures. In the 19th century, global markets and new industrial products drove a significant effort to synthesize artificial dyes, characterized by low production costs, huge quantities, and new optical properties (colors). Dyes that encompass classes of molecules absorbing in the UV-visible part of the electromagnetic spectrum now have a wider range of applications, including coloring (textiles, food, paintings), energy production (photovoltaic cells, OLEDs), or pharmaceuticals (diagnostics, drugs). Parallel to the growth in dye applications, researchers have increased their efforts to design and synthesize new dyes to customize absorption and emission properties. In particular, dyes containing one or more metallic centers allow for the construction of fairly sophisticated systems capable of selectively reacting to light of a given wavelength and behaving as molecular devices (photochemical molecular devices, PMDs).Theoretical tools able to predict and interpret the excited-state properties of organic and inorganic dyes allow for an efficient screening of photochemical centers. In this Account, we report recent developments defining a quantitative ab initio protocol (based on time-dependent density functional theory) for modeling dye spectral properties. In particular, we discuss the importance of several parameters, such as the methods used for electronic structure calculations, solvent effects, and statistical treatments. In addition, we illustrate the performance of such simulation tools through case studies. We also comment on current weak points of these methods and ways to improve them.

  17. Immunosensors in Clinical Laboratory Diagnostics.

    PubMed

    Justino, Celine I L; Duarte, Armando C; Rocha-Santos, Teresa A P

    2016-01-01

    The application of simple, cost-effective, rapid, and accurate diagnostic technologies for detection and identification of cardiac and cancer biomarkers has been a central point in the clinical area. Biosensors have been recognized as efficient alternatives for the diagnostics of various diseases due to their specificity and potential for application on real samples. The role of nanotechnology in the construction of immunological biosensors, that is, immunosensors, has contributed to the improvement of sensitivity, since they are based in the affinity between antibody and antigen. Other analytes than biomarkers such as hormones, pathogenic bacteria, and virus have also been detected by immunosensors for clinical point-of-care applications. In this chapter, we first introduced the various types of immunosensors and discussed their applications in clinical diagnostics over the recent 6 years, mainly as point-of-care technologies for the determination of cardiac and cancer biomarkers, hormones, pathogenic bacteria, and virus. The future perspectives of these devices in the field of clinical diagnostics are also evaluated.

  18. Huntington Disease: Molecular Diagnostics Approach.

    PubMed

    Bastepe, Murat; Xin, Winnie

    2015-10-06

    Huntington disease (HD) is caused by expansion of a CAG trinucleotide repeat in the first exon of the Huntingtin (HTT) gene. Molecular testing of Huntington disease for diagnostic confirmation and disease prediction requires detection of the CAG repeat expansion. There are three main types of HD genetic testing: (1) diagnostic testing to confirm or rule out disease, (2) presymptomatic testing to determine whether an at-risk individual inherited the expanded allele, and (3) prenatal testing to determine whether the fetus has inherited the expanded allele. This unit includes protocols that describe the complementary use of polymerase chain reactions (PCR) and Southern blot hybridization to accurately measure the CAG trinucleotide repeat size and interpret the test results. In addition, an indirect linkage analysis that does not reveal the unwanted parental HD status in a prenatal testing will also be discussed.

  19. Nucleic acid probes in diagnostic medicine

    NASA Technical Reports Server (NTRS)

    Oberry, Phillip A.

    1991-01-01

    The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.

  20. Surgical Procedures. Second Edition. Teacher Edition.

    ERIC Educational Resources Information Center

    Baker, Beverly; And Others

    This teacher's guide contains 13 units of instruction for a course that will prepare students with the entry-level competencies needed by a surgical technologist. The course covers the following topics: introduction to surgical procedures; diagnostic procedures; general surgery; gastrointestinal surgery; obstetrics and gynecological surgery;…

  1. A Framework to Debug Diagnostic Matrices

    NASA Technical Reports Server (NTRS)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  2. Accurate ab Initio Spin Densities.

    PubMed

    Boguslawski, Katharina; Marti, Konrad H; Legeza, Ors; Reiher, Markus

    2012-06-12

    We present an approach for the calculation of spin density distributions for molecules that require very large active spaces for a qualitatively correct description of their electronic structure. Our approach is based on the density-matrix renormalization group (DMRG) algorithm to calculate the spin density matrix elements as a basic quantity for the spatially resolved spin density distribution. The spin density matrix elements are directly determined from the second-quantized elementary operators optimized by the DMRG algorithm. As an analytic convergence criterion for the spin density distribution, we employ our recently developed sampling-reconstruction scheme [J. Chem. Phys.2011, 134, 224101] to build an accurate complete-active-space configuration-interaction (CASCI) wave function from the optimized matrix product states. The spin density matrix elements can then also be determined as an expectation value employing the reconstructed wave function expansion. Furthermore, the explicit reconstruction of a CASCI-type wave function provides insight into chemically interesting features of the molecule under study such as the distribution of α and β electrons in terms of Slater determinants, CI coefficients, and natural orbitals. The methodology is applied to an iron nitrosyl complex which we have identified as a challenging system for standard approaches [J. Chem. Theory Comput.2011, 7, 2740].

  3. Production Pathways and Separation Procedures for High-Diagnostic-Value Activation Species, Fission Products, and Actinides Required for Preparation of Realistic Synthetic Post-Detonation Nuclear Debris: Status Report and FY16 Project Plan

    SciTech Connect

    Faye, S. A.; Shaughnessy, D. A.

    2015-08-19

    The objective of this project is to provide a comprehensive study on the production routes and chemical separation requirements for activation products, fission products, and actinides required for the creation of realistic post-detonation surrogate debris. Isotopes that have been prioritized by debris diagnosticians will be examined for their ability to be produced at existing irradiation sources, production rates, and availability of target materials, and chemical separation procedures required to rapidly remove the products from the bulk target matrix for subsequent addition into synthetic debris samples. The characteristics and implications of the irradiation facilities on the isotopes of interest will be addressed in addition to a summary of the isotopes that are already regularly produced. This is a planning document only.

  4. Dental Procedures.

    PubMed

    Ramponi, Denise R

    2016-01-01

    Dental problems are a common complaint in emergency departments in the United States. There are a wide variety of dental issues addressed in emergency department visits such as dental caries, loose teeth, dental trauma, gingival infections, and dry socket syndrome. Review of the most common dental blocks and dental procedures will allow the practitioner the opportunity to make the patient more comfortable and reduce the amount of analgesia the patient will need upon discharge. Familiarity with the dental equipment, tooth, and mouth anatomy will help prepare the practitioner for to perform these dental procedures.

  5. Biostatistics Series Module 7: The Statistics of Diagnostic Tests.

    PubMed

    Hazra, Avijit; Gogtay, Nithya

    2017-01-01

    Crucial therapeutic decisions are based on diagnostic tests. Therefore, it is important to evaluate such tests before adopting them for routine use. Although things such as blood tests, cultures, biopsies, and radiological imaging are obvious diagnostic tests, it is not to be forgotten that specific clinical examination procedures, scoring systems based on physiological or psychological evaluation, and ratings based on questionnaires are also diagnostic tests and therefore merit similar evaluation. In the simplest scenario, a diagnostic test will give either a positive (disease likely) or negative (disease unlikely) result. Ideally, all those with the disease should be classified by a test as positive and all those without the disease as negative. Unfortunately, practically no test gives 100% accurate results. Therefore, leaving aside the economic question, the performance of diagnostic tests is evaluated on the basis of certain indices such as sensitivity, specificity, positive predictive value, and negative predictive value. Likelihood ratios combine information on specificity and sensitivity to expresses the likelihood that a given test result would occur in a subject with a disorder compared to the probability that the same result would occur in a subject without the disorder. Not all test can be categorized simply as "positive" or "negative." Physicians are frequently exposed to test results on a numerical scale, and in such cases, judgment is required in choosing a cutoff point to distinguish normal from abnormal. Naturally, a cutoff value should provide the greatest predictive accuracy, but there is a trade-off between sensitivity and specificity here - if the cutoff is too low, it will identify most patients who have the disease (high sensitivity) but will also incorrectly identify many who do not (low specificity). A receiver operating characteristic curve plots pairs of sensitivity versus (1 - specificity) values and helps in selecting an optimum cutoff

  6. Biostatistics Series Module 7: The Statistics of Diagnostic Tests

    PubMed Central

    Hazra, Avijit; Gogtay, Nithya

    2017-01-01

    Crucial therapeutic decisions are based on diagnostic tests. Therefore, it is important to evaluate such tests before adopting them for routine use. Although things such as blood tests, cultures, biopsies, and radiological imaging are obvious diagnostic tests, it is not to be forgotten that specific clinical examination procedures, scoring systems based on physiological or psychological evaluation, and ratings based on questionnaires are also diagnostic tests and therefore merit similar evaluation. In the simplest scenario, a diagnostic test will give either a positive (disease likely) or negative (disease unlikely) result. Ideally, all those with the disease should be classified by a test as positive and all those without the disease as negative. Unfortunately, practically no test gives 100% accurate results. Therefore, leaving aside the economic question, the performance of diagnostic tests is evaluated on the basis of certain indices such as sensitivity, specificity, positive predictive value, and negative predictive value. Likelihood ratios combine information on specificity and sensitivity to expresses the likelihood that a given test result would occur in a subject with a disorder compared to the probability that the same result would occur in a subject without the disorder. Not all test can be categorized simply as “positive” or “negative.” Physicians are frequently exposed to test results on a numerical scale, and in such cases, judgment is required in choosing a cutoff point to distinguish normal from abnormal. Naturally, a cutoff value should provide the greatest predictive accuracy, but there is a trade-off between sensitivity and specificity here - if the cutoff is too low, it will identify most patients who have the disease (high sensitivity) but will also incorrectly identify many who do not (low specificity). A receiver operating characteristic curve plots pairs of sensitivity versus (1 − specificity) values and helps in selecting an

  7. Optical Diagnostics in Medicine

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor

    2003-03-01

    Light has a unique potential for non-invasive tissue diagnosis. The relatively short wavelength of light allows imaging of tissue at the resolution of histopathology. While strong multiple scattering of light in tissue makes attainment of this resolution difficult for thick tissues, most pathology emanates from epithelial surfaces. Therefore, high-resolution diagnosis of many important diseases may be achieved by transmitting light to the surface of interest. The recent fiber-optic implementation of technologies that reject multiple scattering, such as confocal microscopy and optical low coherence interferometry, have brought us one step closer to realizing non-invasive imaging of architectural and cellular features of tissue. Optical coherence tomography (OCT) can produce high-resolution cross-sectional images of biological structures. Clinical OCT studies conducted in the gastrointestinal tract and cardiovascular system have shown that OCT is capable of providing images of the architectural (> 20 µm) microanatomy of a variety of epithelial tissues, including the layered structure of squamous epithelium and arterial vessels. Fine Needle Aspiration- Low Coherence Interferometry (FNA-LCI) is another optical diagnostics technique, which is a suitable solution to increase the effectiveness of the FNA procedures. LCI is capable of measuring depth resolved (axial, z) tissue structure, birefringence, flow (Doppler shift), and spectra at a resolution of several microns. Since LCI systems are fiber-optic based, LCI probes may easily fit within the bore of a fine gauge needle, allowing diagnostic information to be obtained directly from the FNA biopsy site. Fiber optic spectrally encoded confocal microscopy (SECM) is a new confocal microscopy method, which eliminates the need for rapid beam scanning within the optical probe. This advance enables confocal microscopy to be performed through small diameter probes and will allow assessment of internal human tissues in vivo at

  8. Diagnostic imaging for aortic dissection.

    PubMed

    Kapustin, Andrew J; Litt, Harold I

    2005-01-01

    Diagnostic imaging for aortic dissection has dramatically changed in recent years. Previously, imaging consisted of conventional X-ray radiography, followed by invasive catheter angiography. Now imaging of dissection is performed primarily with multidetector CT, and to a lesser extent, with ultrasound and MRI. Catheter angiography is used primarily as a means of treating complications. Which modality to choose depends on patient factors, physician preference, and differences in availability of state-of-the-art equipment. All three modalities are highly accurate in experienced hands and have revolutionized the detection and evaluation of this condition.

  9. Evaluation of Commercially Available Serologic Diagnostic Tests for Chikungunya Virus

    PubMed Central

    Flusin, Olivier; Panella, Amanda; Tenebray, Bernard; Lanciotti, Robert; Leparc-Goffart, Isabelle

    2014-01-01

    Chikungunya virus (CHIKV) is present or emerging in dengue virus–endemic areas. Infections caused by these viruses share some common signs/symptoms, but prognosis, patient care, and persistent symptoms differ. Thus, accurate diagnostic methods are essential for differentiating the infections. We evaluated 4 CHIKV serologic diagnostic tests, 2 of which showed poor sensitivity and specificity. PMID:25418184

  10. Accurate, reproducible measurement of blood pressure.

    PubMed Central

    Campbell, N R; Chockalingam, A; Fodor, J G; McKay, D W

    1990-01-01

    The diagnosis of mild hypertension and the treatment of hypertension require accurate measurement of blood pressure. Blood pressure readings are altered by various factors that influence the patient, the techniques used and the accuracy of the sphygmomanometer. The variability of readings can be reduced if informed patients prepare in advance by emptying their bladder and bowel, by avoiding over-the-counter vasoactive drugs the day of measurement and by avoiding exposure to cold, caffeine consumption, smoking and physical exertion within half an hour before measurement. The use of standardized techniques to measure blood pressure will help to avoid large systematic errors. Poor technique can account for differences in readings of more than 15 mm Hg and ultimately misdiagnosis. Most of the recommended procedures are simple and, when routinely incorporated into clinical practice, require little additional time. The equipment must be appropriate and in good condition. Physicians should have a suitable selection of cuff sizes readily available; the use of the correct cuff size is essential to minimize systematic errors in blood pressure measurement. Semiannual calibration of aneroid sphygmomanometers and annual inspection of mercury sphygmomanometers and blood pressure cuffs are recommended. We review the methods recommended for measuring blood pressure and discuss the factors known to produce large differences in blood pressure readings. PMID:2192791

  11. A randomized controlled trial to assess the impact of dietary energy sources, feed supplements, and the presence of super-shedders on the detection of Escherichia coli O157:H7 in feedlot cattle using different diagnostic procedures.

    PubMed

    Cernicchiaro, Natalia; Pearl, David L; McEwen, Scott A; Zerby, Henry N; Fluharty, Francis L; Loerch, Steve C; Kauffman, Michael D; Bard, Jaime L; LeJeune, Jeffrey T

    2010-09-01

    Alteration of the gastro-intestinal tract through manipulation of cattle diets has been proposed as a preharvest control measure to reduce fecal shedding of Escherichia coli O157:H7. The objective of this study was to examine the effects of the energy source's moisture content (high moisture corn and dry whole-shelled corn), two natural feed supplements (Saccaromyces cerevisiae boulardii CNCM 1079-Levucell and Aspergillus oryzae-Amaferm), and two levels of vitamin A (2200 IU/kg and no supplementation) on the fecal excretion of E. coli O157:H7 in naturally infected cattle. One hundred sixty-eight Angus-cross beef steers were randomly allocated to 24 pens, and each pen was assigned 1 of 12 dietary treatments in a randomized complete block design. E. coli O157:H7 was detected by rectoanal mucosal swab (RAMS) and fecal grab samples using immunomagnetic separation (IMS) and standard microbiological techniques. On the basis of multivariable multilevel logistic regression models, we found a statistically significant (p < 0.05) increase in the prevalence of E. coli O157:H7 in animals fed dry whole-shelled corn in models based on fecal-IMS, and this effect was increased if a super-shedding animal (shedding > 10(4) colony forming units of E. coli O157:H7 per gram of feces) was present in the pen at the time of testing relative to animals fed high moisture corn and nonexposed to super-shedders. However, in similar models based on RAMS-IMS testing, the effect of corn type on the prevalence of E. coli O157:H7 varied with the type of feed additive used. Being exposed to a super-shedding pen-mate also increased the odds of being positive to E. coli O157:H7 in the RAMS-IMS models. These models demonstrate that the impact of different supplements may vary with the diagnostic test used, and that further research into the biological significance of differences between RAMS- and fecal-IMS test results is warranted.

  12. R&D ERL: Diagnostics

    SciTech Connect

    Gassner, D.

    2010-01-01

    The Energy Recovery Linac (ERL) prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This report outlines requirements on the ERL diagnostics and describes its setup and modes of operation. The BNL Prototype ERL is an R&D effort aimed at reducing risks and costs associated with the proposed RHIC II electron cooler and eRHIC collider. The ERL will serve as a test bed for developing and testing instrumentation and studying physics and technological issues relevant to very high current ERL's. The prototype ERL, mated to a high current SRF gun, is expected to demonstrate production and energy recovery of high intensity, low emittance beams with a current of up to a few hundred milliamps. To successfully accomplish this task the ERL will include beam diagnostics required to characterize and tune beam parameters, as well as for machine protection. A preliminary diagnostics plan was presented in earlier publications. In this report, we describe the diagnostics presently planned to provide the data needed to meet these goals.

  13. Multigrid time-accurate integration of Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Arnone, Andrea; Liou, Meng-Sing; Povinelli, Louis A.

    1993-01-01

    Efficient acceleration techniques typical of explicit steady-state solvers are extended to time-accurate calculations. Stability restrictions are greatly reduced by means of a fully implicit time discretization. A four-stage Runge-Kutta scheme with local time stepping, residual smoothing, and multigridding is used instead of traditional time-expensive factorizations. Some applications to natural and forced unsteady viscous flows show the capability of the procedure.

  14. Diagnostic Algorithm Benchmarking

    NASA Technical Reports Server (NTRS)

    Poll, Scott

    2011-01-01

    A poster for the NASA Aviation Safety Program Annual Technical Meeting. It describes empirical benchmarking on diagnostic algorithms using data from the ADAPT Electrical Power System testbed and a diagnostic software framework.

  15. Prenatal Genetic Diagnostic Tests

    MedlinePlus

    ... Education & Events Advocacy For Patients About ACOG Prenatal Genetic Diagnostic Tests Home For Patients Search FAQs Prenatal ... Pamphlets - Spanish FAQ164, September 2016 PDF Format Prenatal Genetic Diagnostic Tests Pregnancy What is prenatal genetic testing? ...

  16. Accurate inference of subtle population structure (and other genetic discontinuities) using principal coordinates

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Accurate inference of genetic discontinuities between populations is an essential component of intraspecific biodiversity and evolution studies, as well as associative genetics. The most widely used methods to infer population structure are model based, Bayesian MCMC procedures that minimize Hardy...

  17. Diagnostics for ITER

    SciTech Connect

    Donne, A. J. H.; Hellermann, M. G. von; Barnsley, R.

    2008-10-22

    After an introduction into the specific challenges in the field of diagnostics for ITER (specifically high level of nuclear radiation, long pulses, high fluxes of particles to plasma facing components, need for reliability and robustness), an overview will be given of the spectroscopic diagnostics foreseen for ITER. The paper will describe both active neutral-beam based diagnostics as well as passive spectroscopic diagnostics operating in the visible, ultra-violet and x-ray spectral regions.

  18. Interventional procedures in the chest.

    PubMed

    Vollmer Torrubiano, I; Sánchez González, M

    2016-05-01

    Many thoracic conditions will require an interventional procedure for diagnosis and/or treatment. For this reason, radiologists need to know the indications and the technique for each procedure. In this article, we review the various interventional procedures that radiologists should know and the indications for each procedure. We place special emphasis on the potential differences in the diagnostic results and complications between fine-needle aspiration and biopsy. We also discuss the indications for radiofrequency ablation of lung tumors and review the concepts related to the drainage of pulmonary abscesses. We devote special attention to the management of pleural effusion, covering the indications for thoracocentesis and when to use imaging guidance, and to the protocol for pleural drainage. We also discuss the indications for percutaneous treatment of pericardial effusion and the possible complications of this treatment. Finally, we discuss the interventional management of mediastinal lesions and provide practical advice about how to approach these lesions to avoid serious complications.

  19. Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited).

    PubMed

    Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H

    2010-10-01

    Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.

  20. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  1. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  2. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  3. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  4. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  5. ISHM-oriented adaptive fault diagnostics for avionics based on a distributed intelligent agent system

    NASA Astrophysics Data System (ADS)

    Xu, Jiuping; Zhong, Zhengqiang; Xu, Lei

    2015-10-01

    In this paper, an integrated system health management-oriented adaptive fault diagnostics and model for avionics is proposed. With avionics becoming increasingly complicated, precise and comprehensive avionics fault diagnostics has become an extremely complicated task. For the proposed fault diagnostic system, specific approaches, such as the artificial immune system, the intelligent agents system and the Dempster-Shafer evidence theory, are used to conduct deep fault avionics diagnostics. Through this proposed fault diagnostic system, efficient and accurate diagnostics can be achieved. A numerical example is conducted to apply the proposed hybrid diagnostics to a set of radar transmitters on an avionics system and to illustrate that the proposed system and model have the ability to achieve efficient and accurate fault diagnostics. By analyzing the diagnostic system's feasibility and pragmatics, the advantages of this system are demonstrated.

  6. Target Diagnostics Supports NIF's Path to Ignition

    SciTech Connect

    Shelton, R

    2011-12-07

    The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by

  7. Diagnostics for Fast Ignition Science

    SciTech Connect

    MacPhee, A; Akli, K; Beg, F; Chen, C; Chen, H; Clarke, R; Hey, D; Freeman, R; Kemp, A; Key, M; King, J; LePape, S; Link, A; Ma, T; Nakamura, N; Offermann, D; Ovchinnikov, V; Patel, P; Phillips, T; Stephens, R; Town, R; Wei, M; VanWoerkom, L; Mackinnon, A

    2008-05-06

    The concept for Electron Fast Ignition Inertial Confinement Fusion demands sufficient laser energy be transferred from the ignitor pulse to the assembled fuel core via {approx}MeV electrons. We have assembled a suite of diagnostics to characterize such transfer. Recent experiments have simultaneously fielded absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256eV; spherically bent crystal imagers at 4 and 8keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung and electron and proton spectrometers (along the same line of sight); nuclear activation samples and a picosecond optical probe based interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following laser-plasma interactions at extremely high intensities in both planar and conical targets. Augmented with accurate on-shot laser focal spot and pre-pulse characterization, these measurements are yielding new insight into energy coupling and are providing critical data for validating numerical PIC and hybrid PIC simulation codes in an area that is crucial for many applications, particularly fast ignition. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultra high intensity laser plasma interactions are discussed, together with implications for full-scale fast ignition experiments.

  8. High Energy Laser Diagnostic Sensors

    NASA Astrophysics Data System (ADS)

    Luke, James R.; Goddard, Douglas N.; Lewis, Jay; Thomas, David

    2010-10-01

    Recent advancements in high energy laser (HEL) sources have outpaced diagnostic tools capable of accurately quantifying system performance. Diagnostic tools are needed that allow system developers to measure the parameters that define HEL effectiveness. The two critical parameters for quantifying HEL effectiveness are the irradiance on target and resultant rise in target temperature. Off-board sensing has its limitations, including unpredictable changes in the reflectivity of the target, smoke and outgassing, and atmospheric distortion. On-board sensors overcome the limitations of off-board techniques but must survive high irradiance levels and extreme temperatures. We have developed sensors for on-target diagnostics of high energy laser beams and for the measurement of the thermal response of the target. The conformal sensors consist of an array of quantum dot photodetectors and resistive temperature detectors. The sensor arrays are lithographically fabricated on flexible substrates and can be attached to a variety of laser targets. We have developed a nanoparticle adhesive process that provides good thermal contact with the target and that ensures the sensor remains attached to the target for as long as the target survives. We have calibrated the temperature and irradiance sensors and demonstrated them in a HEL environment.

  9. Pneumoperitoneum, Retropneumoperitoneum, Pneumomediastinum, and Diffuse Subcutaneous Emphysema following Diagnostic Colonoscopy

    PubMed Central

    Falidas, Evangelos; Anyfantakis, Georgios; Vlachos, Konstantinos; Goudeli, Christina; Stavros, Boutzouvis; Villias, Constantinos

    2012-01-01

    Colonoscopy is a widely used diagnostic and curative procedure. Extraperitoneal perforation with pneumoretroperitoneum, pneumomediastinum and subcutaneous emphysema combined with intraperitoneal perforation is an extremely rare complication. We report a case of a 78-year-old woman presented to the emergency department with abdominal pain and diffuse abdominal, chest, neck, and facial swelling appeared after a diagnostic colonoscopy. Diagnostic and therapeutic modalities are discussed. PMID:23024878

  10. Accurate orbit propagation with planetary close encounters

    NASA Astrophysics Data System (ADS)

    Baù, Giulio; Milani Comparetti, Andrea; Guerra, Francesca

    2015-08-01

    We tackle the problem of accurately propagating the motion of those small bodies that undergo close approaches with a planet. The literature is lacking on this topic and the reliability of the numerical results is not sufficiently discussed. The high-frequency components of the perturbation generated by a close encounter makes the propagation particularly challenging both from the point of view of the dynamical stability of the formulation and the numerical stability of the integrator. In our approach a fixed step-size and order multistep integrator is combined with a regularized formulation of the perturbed two-body problem. When the propagated object enters the region of influence of a celestial body, the latter becomes the new primary body of attraction. Moreover, the formulation and the step-size will also be changed if necessary. We present: 1) the restarter procedure applied to the multistep integrator whenever the primary body is changed; 2) new analytical formulae for setting the step-size (given the order of the multistep, formulation and initial osculating orbit) in order to control the accumulation of the local truncation error and guarantee the numerical stability during the propagation; 3) a new definition of the region of influence in the phase space. We test the propagator with some real asteroids subject to the gravitational attraction of the planets, the Yarkovsky and relativistic perturbations. Our goal is to show that the proposed approach improves the performance of both the propagator implemented in the OrbFit software package (which is currently used by the NEODyS service) and of the propagator represented by a variable step-size and order multistep method combined with Cowell's formulation (i.e. direct integration of position and velocity in either the physical or a fictitious time).

  11. [Diagnostic criteria for neuromyelitisoptica spectrum disorders].

    PubMed

    Belova, A N; Boiko, A N; Belova, E M

    2016-01-01

    The review is devoted to revised international diagnostic criteria for neuromyelitisoptica spectrum disorders (NMOSD).Current diagnostic criteria allow NMOSD diagnosis not only for serum aquaporin-4 immunoglobulin G antibodies (AQP4-IgG)-seropositive patients but for AQP4-IgG-seronegative patients as well. New criteria are expected to make NMOSD diagnosis earlier and more accurate as well as to facilitate the differentiation with multiple sclerosis. Furthermore, unify international criteria should help to perform comparable epidemiologic studies and clinical trials of new drugs for NMOSD.

  12. Commissioning activities of the initial magnetic diagnostics for KSTAR tokamak

    NASA Astrophysics Data System (ADS)

    Lee, Sang Gon; Gyo Bak, Jun; Mie Ka, Eun

    2007-11-01

    The initial magnetic diagnostics for the KSTAR superconducting tokamak including three Rogowski coils, five flux/voltage loops, and sixty-four magnetic field probes have been successfully installed. The Rogowski coils, flux/voltage loops, and magnetic field probes measure the total plasma current, poloidal flux and loop voltage, and local poloidal magnetic field for the plasma position control and equilibrium studies, respectively. Accurate position measurements after installation for all of these initial magnetic diagnostics and in situ calibration for the Rogowski coils were finished. Data acquisition systems for these initial magnetic diagnostics are currently under preparation. Detail commissioning activities before the first plasma from these initial magnetic diagnostics will be presented.

  13. Ritz Procedure for COSMIC/NASTRAN

    NASA Technical Reports Server (NTRS)

    Citerley, R. L.; Woytowitz, P. J.

    1985-01-01

    An analysis procedure has been developed and incorporated into COSMIC/NASTRAN that permits large dynamic degree of freedom models to be processed accurately with little or no extra effort required by the user. The method employs existing capabilities without the need for approximate Guyan reduction techniques. Comparisons to existing solution procedures presently within NASTRAN are discussed.

  14. Procedural knowledge

    NASA Technical Reports Server (NTRS)

    Georgeff, Michael P.; Lansky, Amy L.

    1986-01-01

    Much of commonsense knowledge about the real world is in the form of procedures or sequences of actions for achieving particular goals. In this paper, a formalism is presented for representing such knowledge using the notion of process. A declarative semantics for the representation is given, which allows a user to state facts about the effects of doing things in the problem domain of interest. An operational semantics is also provided, which shows how this knowledge can be used to achieve particular goals or to form intentions regarding their achievement. Given both semantics, the formalism additionally serves as an executable specification language suitable for constructing complex systems. A system based on this formalism is described, and examples involving control of an autonomous robot and fault diagnosis for NASA's Space Shuttle are provided.

  15. Accurate modelling of unsteady flows in collapsible tubes.

    PubMed

    Marchandise, Emilie; Flaud, Patrice

    2010-01-01

    The context of this paper is the development of a general and efficient numerical haemodynamic tool to help clinicians and researchers in understanding of physiological flow phenomena. We propose an accurate one-dimensional Runge-Kutta discontinuous Galerkin (RK-DG) method coupled with lumped parameter models for the boundary conditions. The suggested model has already been successfully applied to haemodynamics in arteries and is now extended for the flow in collapsible tubes such as veins. The main difference with cardiovascular simulations is that the flow may become supercritical and elastic jumps may appear with the numerical consequence that scheme may not remain monotone if no limiting procedure is introduced. We show that our second-order RK-DG method equipped with an approximate Roe's Riemann solver and a slope-limiting procedure allows us to capture elastic jumps accurately. Moreover, this paper demonstrates that the complex physics associated with such flows is more accurately modelled than with traditional methods such as finite difference methods or finite volumes. We present various benchmark problems that show the flexibility and applicability of the numerical method. Our solutions are compared with analytical solutions when they are available and with solutions obtained using other numerical methods. Finally, to illustrate the clinical interest, we study the emptying process in a calf vein squeezed by contracting skeletal muscle in a normal and pathological subject. We compare our results with experimental simulations and discuss the sensitivity to parameters of our model.

  16. Quantitation of intracranial aneurysm neck size from diagnostic angiograms based on a biomathematical model.

    PubMed

    Hademenos, G J; Massoud, T F; Viñuela, F

    1995-10-01

    Accurate measurement of the aneurysm neck size from diagnostic angiograms is crucial in the consideration and implementation of interventional embolotherapeutic procedures. Due to inherent problems in angiography, aneurysm morphology and location, and obstruction by overlying structures, accurate measurement of the aneurysm neck size is difficult. We are proposing a method for the angiographic measurement of aneurysm neck size based on a biomathematical model of an aneurysm. A biomathematical model of an intracranial saccular aneurysm was developed based on Laplace's law for a spherical elastic object, given by: Stress = Pressure x Radius/2 x Wall thickness. In addition, another biomechanical parameter used to describe an elastic sphere is the strain: Strain = delta R/Ri = (R-Ri)/Ri where R is the current aneurysm radius and Ri is the initial radius prior to aneurysm development. The stress and strain of an elastic structure are used to describe the elastic modulus, E: E = stress/strain = [PR/2h]/[(R-Ri)/Ri] = [PRRi]/[2hR-2hri]. It is assumed at this point that no additional tissue growth occurs through the developmental course of the aneurysm. The expression for E is now solved for Ri which, in essence, represents the radius of the aneurysm neck: Ri = [2hER]/[PR + 2hE]. Thus, the diameter of the neck, Dn, is given by Dn = 2 + i = 2 ([2hER]/[PR + 2hE]). During diagnostic angiography, the radius, R, and pressure, P, are easily obtained during the examination procedure. However, it is not possible to angiographically determine the elastic modulus, E, and the wall thickness, h. In this case, the following average values are used: E = 1.0 MPa and h = 50 microns. From the diagnostic angiograms and hospital records of 23 patients, the aneurysm neck size was determined using the biomathematical model and compared to the results obtained from the correlative relationship between the measured and accepted ratios of neck size to diameter of parent artery. The neck diameter

  17. TFTR diagnostic vacuum controller

    SciTech Connect

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  18. Diagnostic Development on NSTX

    SciTech Connect

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-12-16

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted.

  19. Accurate and precise zinc isotope ratio measurements in urban aerosols.

    PubMed

    Gioia, Simone; Weiss, Dominik; Coles, Barry; Arnold, Tim; Babinski, Marly

    2008-12-15

    We developed an analytical method and constrained procedural boundary conditions that enable accurate and precise Zn isotope ratio measurements in urban aerosols. We also demonstrate the potential of this new isotope system for air pollutant source tracing. The procedural blank is around 5 ng and significantly lower than published methods due to a tailored ion chromatographic separation. Accurate mass bias correction using external correction with Cu is limited to Zn sample content of approximately 50 ng due to the combined effect of blank contribution of Cu and Zn from the ion exchange procedure and the need to maintain a Cu/Zn ratio of approximately 1. Mass bias is corrected for by applying the common analyte internal standardization method approach. Comparison with other mass bias correction methods demonstrates the accuracy of the method. The average precision of delta(66)Zn determinations in aerosols is around 0.05 per thousand per atomic mass unit. The method was tested on aerosols collected in Sao Paulo City, Brazil. The measurements reveal significant variations in delta(66)Zn(Imperial) ranging between -0.96 and -0.37 per thousand in coarse and between -1.04 and 0.02 per thousand in fine particular matter. This variability suggests that Zn isotopic compositions distinguish atmospheric sources. The isotopic light signature suggests traffic as the main source. We present further delta(66)Zn(Imperial) data for the standard reference material NIST SRM 2783 (delta(66)Zn(Imperial) = 0.26 +/- 0.10 per thousand).

  20. Diagnostic efficiency of several methods of identifying socially rejected children and effect of participation rate on classification accuracy.

    PubMed

    McKown, Clark; Gumbiner, Laura M; Johnson, Jason

    2011-10-01

    Social rejection is associated with a wide variety of negative outcomes. Early identification of social rejection and intervention to minimize its negative impact is thus important. However, sociometric methods, which are considered high in validity for identifying socially rejected children, are frequently not used because of (a) procedural challenges, (b) community apprehension, and (c) sensitivity to missing data. In a sample of 316 students in grades K through 8, we used receiver operating characteristics (ROC) analyses to compare the diagnostic efficiency of several methods for identifying socially rejected children. When not using least-liked nominations, (a) most-liked nominations yielded the greatest diagnostic efficiency (AUC=.96), (b) peer ratings were more efficient (AUC=.84 to .99) than teacher ratings (AUC=.74 to .81), and (c) teacher report of social status was more efficient (AUC=.81) than scores from teacher behavior rating scales (AUC=.74 to .75). We also examined the effects of nominator non-participation on diagnostic efficiency. At participation as low as 50%, classification of sociometric rejection (i.e., being rejected or not rejected) was quite accurate (κ=.63 to .77). In contrast, at participation as high as 70%, classification of sociometric status (i.e., popular, average, unclassified, neglected, controversial, or rejected) was significantly less accurate (κ=.50 to .59).

  1. Towards increase of diagnostic efficacy in gynecologic OCT

    NASA Astrophysics Data System (ADS)

    Kirillin, Mikhail; Panteleeva, Olga; Eliseeva, Darya; Kachalina, Olga; Sergeeva, Ekaterina; Dubasova, Lyubov; Agrba, Pavel; Mikailova, Gyular; Prudnikov, Maxim; Shakhova, Natalia

    2013-06-01

    Gynecologic applications of optical coherence tomography (OCT) are usually performed in combination with routine diagnostic procedures: laparoscopy and colposcopy. In combination with laparoscopy OCT is employed for inspection of fallopian tubes in cases of unrecognized infertility while in colposcopy it is used to identify cervix pathologies including cancer. In this paper we discuss methods for increasing diagnostic efficacy of OCT application in these procedures. For OCT-laparoscopy we demonstrate independent criteria for pathology recognition which allow to increase accuracy of diagnostics. For OCT-colposcopy we report on application of device for controlled compression allowing to sense the elasticity of the inspected cervix area and distinguish between neoplasia and inflammatory processes.

  2. BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

    SciTech Connect

    R. C. York; X. Wu; Q. Zhao

    2011-12-21

    End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

  3. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  4. What Is Diagnostic Testing?

    MedlinePlus

    ... Primary care providers Specialists Getting covered Research Basic science research Research in people ... screening Diagnostic testing Direct-to-consumer genetic testing Newborn screening Pharmacogenomic testing ...

  5. TFTR diagnostic control and data acquisition system

    SciTech Connect

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  6. TFTR diagnostic control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Sauthoff, N. R.; Daniels, R. E.

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  7. Uniformly high order accurate essentially non-oscillatory schemes 3

    NASA Technical Reports Server (NTRS)

    Harten, A.; Engquist, B.; Osher, S.; Chakravarthy, S. R.

    1986-01-01

    In this paper (a third in a series) the construction and the analysis of essentially non-oscillatory shock capturing methods for the approximation of hyperbolic conservation laws are presented. Also presented is a hierarchy of high order accurate schemes which generalizes Godunov's scheme and its second order accurate MUSCL extension to arbitrary order of accuracy. The design involves an essentially non-oscillatory piecewise polynomial reconstruction of the solution from its cell averages, time evolution through an approximate solution of the resulting initial value problem, and averaging of this approximate solution over each cell. The reconstruction algorithm is derived from a new interpolation technique that when applied to piecewise smooth data gives high-order accuracy whenever the function is smooth but avoids a Gibbs phenomenon at discontinuities. Unlike standard finite difference methods this procedure uses an adaptive stencil of grid points and consequently the resulting schemes are highly nonlinear.

  8. Bone marrow lesions: A systematic diagnostic approach

    PubMed Central

    Grande, Filippo Del; Farahani, Sahar J; Carrino, John A; Chhabra, Avneesh

    2014-01-01

    Bone marrow lesions on magnetic resonance (MR) imaging are common and may be seen with various pathologies. The authors outline a systematic diagnostic approach with proposed categorization of various etiologies of bone marrow lesions. Utilization of typical imaging features on conventional MR imaging techniques and other problem-solving techniques, such as chemical shift imaging and diffusion-weighted imaging (DWI), to achieve accurate final diagnosis has been highlighted. PMID:25114392

  9. Acute dizziness in rural practice: Proposal of a diagnostic procedure

    PubMed Central

    Eid, Ehab; Dastan, Sajed; Heckmann, Josef G.

    2015-01-01

    Acute dizziness is a frequent index symptom in the emergency department as well as in the rural practice office. Most acute dizziness, however, is not dangerous, but some types are highly dangerous. Clinical routine acute dizziness can be separated into frequent benign syndromes including benign paroxysmal positional vertigo (BPPV), vestibular neuritis, Meniθre's disease or vestibular migraine, and what is here referred to as the “white shark” of dizziness, i.e. a stroke in the posterior circulation or more rarely a tumor in the posterior fossa. A practical concept is presented to clarify most frequent acute dizziness syndromes using clinical and low budget methods. PMID:25883501

  10. Acute dizziness in rural practice: Proposal of a diagnostic procedure.

    PubMed

    Eid, Ehab; Dastan, Sajed; Heckmann, Josef G

    2015-01-01

    Acute dizziness is a frequent index symptom in the emergency department as well as in the rural practice office. Most acute dizziness, however, is not dangerous, but some types are highly dangerous. Clinical routine acute dizziness can be separated into frequent benign syndromes including benign paroxysmal positional vertigo (BPPV), vestibular neuritis, Meniθre's disease or vestibular migraine, and what is here referred to as the "white shark" of dizziness, i.e. a stroke in the posterior circulation or more rarely a tumor in the posterior fossa. A practical concept is presented to clarify most frequent acute dizziness syndromes using clinical and low budget methods.

  11. Diagnostic and therapeutic-restorative procedures for masticatory dysfunctions

    PubMed Central

    Freesmeyer, Wolfgang B.; Fussnegger, M. R.; Ahlers, M. O.

    2005-01-01

    Temporomandibular disorders (TMD) or craniomandibular disorders, respectively, involve diseases of the teeth and periodontia as well as the masticatory muscles, temporomandibular joints and associated structures. It has been shown in recent years that psychological, social and general medical influences are of enormous importance in the etiology of TMD in addition to anatomical, physiological, parafunctional and other biological causes. This signifies that therapists confronted with TMD should already include at an early stage other specialists such as pain therapists, neurologists, ENT physicians, psychotherapists and physiotherapists. Patients need to be referred to dentists specializing in TMD when ENT examinations yield no pathological findings. The treatment of TMD is subdivided into the following steps that are always related to underlying diagnoses: informing patients, self-observation, relaxation therapy, behavioral therapy, physiotherapy, drug therapy, therapeutic local anesthesia, splint therapy, and, if necessary, prosthetic and/or orthodontic therapy to restore a stable occlusion. PMID:22073067

  12. Acquiring, Representing, and Evaluating a Competence Model of Diagnostic Strategy.

    ERIC Educational Resources Information Center

    Clancey, William J.

    This paper describes NEOMYCIN, a computer program that models one physician's diagnostic reasoning within a limited area of medicine. NEOMYCIN's knowledge base and reasoning procedure constitute a model of how human knowledge is organized and how it is used in diagnosis. The hypothesis is tested that such a procedure can be used to simulate both…

  13. [Diagnostic reference levels in interventional radiology].

    PubMed

    Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I

    2013-12-01

    This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures.

  14. Automotive Diagnostic Technologies.

    ERIC Educational Resources Information Center

    Columbus State Community Coll., OH.

    This document contains materials developed for and about the automotive diagnostic technologies tech prep program of the South-Western City Schools in Ohio. Part 1 begins with a map of the program, which begins with an automotive/diagnostic technologies program in grades 11 and 12 that leads to entry-level employment or a 2-year automotive…

  15. A Review of the Diagnostic Methods Reported in the Journal of Autism and Developmental Disorders.

    ERIC Educational Resources Information Center

    Waller, Stacey A.; Armstrong, Kevin J.; McGrath, Ann M.; Sullivan, Cristin L.

    1999-01-01

    This review summarizes subject selection and diagnostic procedures documented in 142 empirical articles published between 1993 and 1997. Although most researchers reported use of standard diagnostic criteria in classifying subjects, numerous studies did not report diagnostic methods and there was often a lack of specification of inclusion and…

  16. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  17. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  18. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  19. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  20. Diagnostics of Nanodusty Plasma

    NASA Astrophysics Data System (ADS)

    Greiner, Franko; Groth, Sebastian; Tadsen, Bejamin; Piel, Alexander

    2015-11-01

    The diagnostic of nanodusty plasmas, i.e. plasmas including nano-sized dust particles, is a challenging task. For both, the diagnostic of the nanodusty plasma itself, and the in-situ diagnostic of the nanoparticles, no standard diagnostic exist. Nanodust particle size and density can be estimated using light scattering techniques, namely kinetic Mie ellipsometry and extinction measurements. The charge of the nanoparticles can be estimated from the analysis of dust density waves (DDW). Parameters like the electron density, which give information about the plasma itself, may be deduced from the DDW analysis. We present detailed investigations on nanodust in a reactive Argon-Acetylene plasma created in an rf-driven parallel plate reactor at low pressure using the above mentioned portfolio of diagnostic. Funded by DFG under contract SFB TR-24/A2.

  1. Rayleigh Scattering Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard (Compiler)

    1996-01-01

    The Rayleigh Scattering Diagnostics Workshop was held July 25-26, 1995 at the NASA Lewis Research Center in Cleveland, Ohio. The purpose of the workshop was to foster timely exchange of information and expertise acquired by researchers and users of laser based Rayleigh scattering diagnostics for aerospace flow facilities and other applications. This Conference Publication includes the 12 technical presentations and transcriptions of the two panel discussions. The first panel was made up of 'users' of optical diagnostics, mainly in aerospace test facilities, and its purpose was to assess areas of potential applications of Rayleigh scattering diagnostics. The second panel was made up of active researchers in Rayleigh scattering diagnostics, and its purpose was to discuss the direction of future work.

  2. Interviewing Children Versus Tossing Coins: Accurately Assessing the Diagnosticity of Children’s Disclosures of Abuse

    PubMed Central

    LYON, THOMAS D.; AHERN, ELIZABETH C.; SCURICH, NICHOLAS

    2014-01-01

    We describe a Bayesian approach to evaluating children’s abuse disclosures and review research demonstrating that children’s disclosure of genital touch can be highly probative of sexual abuse, with the probative value depending on disclosure spontaneity and children’s age. We discuss how some commentators understate the probative value of children’s disclosures by: confusing the probability of abuse given disclosure with the probability of disclosure given abuse, assuming that children formally questioned about sexual abuse have a low prior probability of sexual abuse, misstating the probative value of abuse disclosure, and confusing the distinction between disclosure and nondisclosure with the distinction between true and false disclosures. We review interviewing methods that increase the probative value of disclosures, including interview instructions, narrative practice, noncontingent reinforcement, and questions about perpetrator/caregiver statements and children’s reactions to the alleged abuse. PMID:22339423

  3. Interviewing Children versus Tossing Coins: Accurately Assessing the Diagnosticity of Children's Disclosures of Abuse

    ERIC Educational Resources Information Center

    Lyon, Thomas D.; Ahern, Elizabeth C.; Scurich, Nicholas

    2012-01-01

    We describe a Bayesian approach to evaluating children's abuse disclosures and review research demonstrating that children's disclosure of genital touch can be highly probative of sexual abuse, with the probative value depending on disclosure spontaneity and children's age. We discuss how some commentators understate the probative value of…

  4. Fast and accurate automated cell boundary determination for fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Arce, Stephen Hugo; Wu, Pei-Hsun; Tseng, Yiider

    2013-07-01

    Detailed measurement of cell phenotype information from digital fluorescence images has the potential to greatly advance biomedicine in various disciplines such as patient diagnostics or drug screening. Yet, the complexity of cell conformations presents a major barrier preventing effective determination of cell boundaries, and introduces measurement error that propagates throughout subsequent assessment of cellular parameters and statistical analysis. State-of-the-art image segmentation techniques that require user-interaction, prolonged computation time and specialized training cannot adequately provide the support for high content platforms, which often sacrifice resolution to foster the speedy collection of massive amounts of cellular data. This work introduces a strategy that allows us to rapidly obtain accurate cell boundaries from digital fluorescent images in an automated format. Hence, this new method has broad applicability to promote biotechnology.

  5. Mill profiler machines soft materials accurately

    NASA Technical Reports Server (NTRS)

    Rauschl, J. A.

    1966-01-01

    Mill profiler machines bevels, slots, and grooves in soft materials, such as styrofoam phenolic-filled cores, to any desired thickness. A single operator can accurately control cutting depths in contour or straight line work.

  6. Writer`s guide for technical procedures

    SciTech Connect

    1998-12-01

    A primary objective of operations conducted in the US Department of Energy (DOE) complex is safety. Procedures are a critical element of maintaining a safety envelope to ensure safe facility operation. This DOE Writer`s Guide for Technical Procedures addresses the content, format, and style of technical procedures that prescribe production, operation of equipment and facilities, and maintenance activities. The DOE Writer`s Guide for Management Control Procedures and DOE Writer`s Guide for Emergency and Alarm Response Procedures are being developed to assist writers in developing nontechnical procedures. DOE is providing this guide to assist writers across the DOE complex in producing accurate, complete, and usable procedures that promote safe and efficient operations that comply with DOE orders, including DOE Order 5480.19, Conduct of Operations for DOE Facilities, and 5480.6, Safety of Department of Energy-Owned Nuclear Reactors.

  7. Diagnostics on Z (invited)

    NASA Astrophysics Data System (ADS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.; Hurst, M.; Jobe, D.; Torres, J.; Seaman, J.; Struve, K.; Lazier, S.; Gilliland, T.; Ruggles, L. A.; Simpson, W. A.; Adams, R.; Seaman, J. A.; Wenger, D.; Nielsen, D.; Riley, P.; French, R.; Stygar, B.; Wagoner, T.; Sanford, T. W. L.; Mock, R.; Asay, J.; Hall, C.; Knudson, M.; Armijo, J.; McKenney, J.; Hawn, R.; Schroen-Carey, D.; Hebron, D.; Cutler, T.; Dropinski, S.; Deeney, C.; LePell, P. D.; Coverdale, C. A.; Douglas, M.; Cuneo, M.; Hanson, D.; Bailey, J. E.; Lake, P.; Carlson, A.; Wakefield, C.; Mills, J.; Slopek, J.; Dinwoodie, T.; Idzorek, G.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12° above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them.

  8. [Role of cytology in hematopathological diagnostics].

    PubMed

    Bode, B; Tinguely, M

    2012-07-01

    The role of cytology has so far been underrecognized in the diagnostic process of hematopathological questions. This article presents an algorithm which allows a stepwise work-up of cytology specimens obtained by minimally invasive ultrasound-guided fine needle aspiration in patients with unexplained lymph node swelling. Moreover, it is shown how the selective separation of cytology specimens allows the application of immunophenotypic analysis including flow cytometry and immunohistochemistry as well as molecular analyses, such as fluorescence in situ hybridization (FISH) and polymerase chain reaction (PCR) strategies. With the integrative procedure presented, cytology offers an excellent cost-effective tool for the diagnostic approach of patients with suspected hematopathological malignancies allowing a high diagnostic accuracy, ideal for initial diagnosis or follow-up.

  9. Cryptosporidiosis: multiattribute evaluation of six diagnostic methods.

    PubMed Central

    MacPherson, D W; McQueen, R

    1993-01-01

    Six diagnostic methods (Giemsa staining, Ziehl-Neelsen staining, auramine-rhodamine staining, Sheather's sugar flotation, an indirect immunofluorescence procedure, and a modified concentration-sugar flotation method) for the detection of Cryptosporidium spp. in stool specimens were compared on the following attributes: diagnostic yield, cost to perform each test, ease of handling, and ability to process large numbers of specimens for screening purposes by batching. A rank ordering from least desirable to most desirable was then established for each method by using the study attributes. The process of decision analysis with respect to the laboratory diagnosis of cryptosporidiosis is discussed through the application of multiattribute utility theory to the rank ordering of the study criteria. Within a specific health care setting, a diagnostic facility will be able to calculate its own utility scores for our study attributes. Multiattribute evaluation and analysis are potentially powerful tools in the allocation of resources in the laboratory. PMID:8432802

  10. Cable Diagnostic Focused Initiative

    SciTech Connect

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  11. Video integrated measurement system. [Diagnostic display devices

    SciTech Connect

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  12. Melioidosis Diagnostic Workshop, 20131

    PubMed Central

    AuCoin, David; Baccam, Prasith; Baggett, Henry C.; Baird, Rob; Bhengsri, Saithip; Blaney, David D.; Brett, Paul J.; Brooks, Timothy J.G.; Brown, Katherine A.; Chantratita, Narisara; Cheng, Allen C.; Dance, David A.B.; Decuypere, Saskia; Defenbaugh, Dawn; Gee, Jay E.; Houghton, Raymond; Jorakate, Possawat; Lertmemongkolchai, Ganjana; Limmathurotsakul, Direk; Merlin, Toby L.; Mukhopadhyay, Chiranjay; Norton, Robert; Peacock, Sharon J.; Rolim, Dionne B.; Simpson, Andrew J.; Steinmetz, Ivo; Stoddard, Robyn A.; Stokes, Martha M.; Sue, David; Tuanyok, Apichai; Whistler, Toni; Wuthiekanun, Vanaporn; Walke, Henry T.

    2015-01-01

    Melioidosis is a severe disease that can be difficult to diagnose because of its diverse clinical manifestations and a lack of adequate diagnostic capabilities for suspected cases. There is broad interest in improving detection and diagnosis of this disease not only in melioidosis-endemic regions but also outside these regions because melioidosis may be underreported and poses a potential bioterrorism challenge for public health authorities. Therefore, a workshop of academic, government, and private sector personnel from around the world was convened to discuss the current state of melioidosis diagnostics, diagnostic needs, and future directions. PMID:25626057

  13. Pediatric diagnostic imaging

    SciTech Connect

    Gyll, C.; Blake, N.S.

    1986-01-01

    This book treats the practical problems of pediatric radiography and radiological procedures. Written jointly by a radiographer and a radiologist, it covers pediatric positioning and procedures. An extended chapter covers neonatal radiography and radiology.

  14. Testing diagnostics of triggered star formation

    NASA Astrophysics Data System (ADS)

    Haworth, Thomas J.; Harries, Tim J.; Acreman, David M.

    2012-10-01

    We produce synthetic images and SEDs from radiation hydrodynamical simulations of radiatively driven implosion. The imaged bright rimmed clouds (BRCs) are morphologically similar to those actually observed in star-forming regions. Using nebular diagnostic optical collisional line ratios, simulated Very Large Array (VLA) radio images, Hα imaging and SED fitting we compute the neutral cloud and ionized boundary layer (IBL) gas densities and temperatures and perform a virial stability analysis for each cloud. We determine that the neutral cloud temperatures derived by SED fitting are hotter than the dominant neutral cloud temperature by 1-2 K due to emission from warm dust. This translates into a change in the calculated cloud mass by 8-35 per cent. Using a constant mass conversion factor (Cν) for BRCs of different class is found to give rise to errors in the cloud mass of up to a factor of 3.6. The IBL electron temperature calculated using diagnostic line ratios is more accurate than assuming the canonical value adopted for radio diagnostics of 104 K. Both radio diagnostics and diagnostic line ratios are found to underestimate the electron density in the IBL. Each system is qualitatively correctly found to be in a state in which the pressure in the IBL is greater than the supporting cloud pressure, implying that the objects are being compressed. We find that observationally derived mass-loss estimates agree with those on the simulation grid and introduce the concept of using the mass-loss flux to give an indication of the relative strength of photoevaporative flow between clouds. The effect of beam size on these diagnostics in radio observations is found to be a mixing of the bright rim and ambient cloud and H II region fluxes, which leads to an underestimate of the cloud properties relative to a control diagnostic.

  15. Recent advances in diagnostic bronchoscopy

    PubMed Central

    Ong, Philip G.; Debiane, Labib G.

    2016-01-01

    The field of diagnostic bronchoscopy has been revolutionized in the last decade primarily with the advent of endobronchial ultrasound (EBUS) but also with the addition of multiple different techniques for “guided-bronchoscopy”. These advances have had a substantial impact in the management of lung cancer with bronchoscopy now providing both diagnosis and mediastinal staging in a single procedure. EBUS has, in fact, become the first choice for staging of the mediastinum over cervical mediastinoscopy (CM). Although EBUS is now a well-established technique, there are continuous efforts from the scientific community to improve its diagnostic performance, and these will be reviewed in this manuscript. The term “guided-bronchoscopy” was recently coined to describe a myriad of techniques that guide our bronchoscopes or bronchoscopic tools into the periphery of the lungs in addition to our conventional fluoroscopy. Electromagnetic and non-electromagnetic navigation, thin and ultrathin scopes, as well as radial-probe EBUS have collectively increased our yield for smaller peripheral lung lesions and continue to evolve. Despite this improved diagnostic yield, there is still ample room for improvement and newer techniques are under way. With new therapies available for patients with interstitial lung disease, achieving a specific histologic diagnosis is now of paramount importance. Given the high morbidity and mortality of surgical biopsies, bronchoscopic cryobiopsy is being rapidly adopted as a safer and effective alternative, and it is likely going to play a major role in the management of these diseases in the near future. This manuscript we will focus on recent advances in EBUS, guided-bronchoscopy, and the use of cryobiopsy. PMID:28149581

  16. Invasive diagnostic techniques in idiopathic interstitial pneumonias.

    PubMed

    Poletti, Venerino; Ravaglia, Claudia; Gurioli, Carlo; Piciucchi, Sara; Dubini, Alessandra; Cavazza, Alberto; Chilosi, Marco; Rossi, Andrea; Tomassetti, Sara

    2016-01-01

    Fibrosing interstitial lung diseases (f-ILDs) represent a heterogeneous group of disorders in which the aetiology may be identified or, not infrequently, remain unknown. Establishing a correct diagnosis of a distinct f-ILD requires a multidisciplinary approach, integrating clinical profile, physiological and laboratory data, radiological appearance and, when appropriate, histological findings. Surgical lung biopsy is still considered the most important diagnostic tool as it is able to provide lung samples large enough for identification of complex patterns such as usual interstitial pneumonitis (UIP) and nonspecific interstitial pneumonitis. However, this procedure is accompanied by significant morbidity and mortality. Bronchoalveolar lavage is still a popular diagnostic tool allowing identification of alternative diagnoses in patients with suspected idiopathic pulmonary fibrosis (IPF) when an increase in lymphocytes is detected. Conventional transbronchial lung biopsy has a very low sensitivity in detecting the UIP pattern and its role in this clinical-radiological context is marginal. The introduction of less invasive methods such as transbronchial cryobiopsy show great promise to clinical practice as they can be used to obtain samples large enough to morphologically support a diagnosis of IPF or other idiopathic interstitial pneumonias, along with fewer complications. Recent advances in the field suggest that less invasive methods of lung sampling, without significant side effects, in combination with other diagnostic methods could replace the need for surgical lung biopsy in the future. Indeed, these new multidisciplinary procedures may become the main diagnostic work-up method for patients with suspected idiopathic interstitial pneumonia.

  17. Multilayer Thin Film Sensors for Damage Diagnostics

    NASA Astrophysics Data System (ADS)

    Protasov, A. G.; Gordienko, Y. G.; Zasimchuk, E. E.

    2006-03-01

    The new innovative approach to damage diagnostics within the production and maintenance/servicing procedures in industry is proposed. It is based on the real-time multiscale monitoring of the smart-designed multilayer thin film sensors of fatigue damage with the standard electrical input/output interfaces which can be connected to the embedded and on-board computers. The multilayer thin film sensors supply information about the actual unpredictable deformation damage, actual fatigue life, strain localization places, damage spreading, etc.

  18. Radiation Safety in Nuclear Medicine Procedures.

    PubMed

    Cho, Sang-Geon; Kim, Jahae; Song, Ho-Chun

    2017-03-01

    Since the nuclear disaster at the Fukushima Daiichi Nuclear Power Plant in 2011, radiation safety has become an important issue in nuclear medicine. Many structured guidelines or recommendations of various academic societies or international campaigns demonstrate important issues of radiation safety in nuclear medicine procedures. There are ongoing efforts to fulfill the basic principles of radiation protection in daily nuclear medicine practice. This article reviews important principles of radiation protection in nuclear medicine procedures. Useful references, important issues, future perspectives of the optimization of nuclear medicine procedures, and diagnostic reference level are also discussed.

  19. Radioactive diagnostic agent

    SciTech Connect

    Shigematsu, A.; Aihara, M.; Matsuda, M.; Suzuki, A.; Tsuya, A.

    1984-02-07

    A radioactive diagnostic agent for renal cortex, adrenal cortex, myocardium, brain stem, spinal nerve, etc., which comprises as an essential component monoiodoacetic acid wherein the iodine atom is radioactive.

  20. Fermilab recycler diagnostics

    SciTech Connect

    Martin Hu

    2001-07-24

    The Fermilab Recycler Ring is a permanent magnet storage ring for the storage and cooling of antiprotons. The following note describes the diagnostic tools currently available for commissioning, as well as the improvements and upgrades planned for the near future.

  1. Fiber diffraction of skin and nails provides an accurate diagnosis of malignancies

    SciTech Connect

    James, Veronica J.

    2009-10-21

    An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatory test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.

  2. Early diagnostic of concurrent gear degradation processes progressing under time-varying loads

    NASA Astrophysics Data System (ADS)

    Guilbault, Raynald; Lalonde, Sébastien

    2016-08-01

    This study develops a gear diagnostic procedure for the detection of multi- and concurrent degradation processes evolving under time-varying loads. Instead of a conventional comparison between a descriptor and an alarm level, this procedure bases its detection strategy on a descriptor evolution tracking; a lasting descriptor increase denotes the presence of ongoing degradation mechanisms. The procedure works from time domain residual signals prepared in the frequency domain, and accepts any gear conditions as reference signature. To extract the load fluctuation repercussions, the procedure integrates a scaling factor. The investigation first examines a simplification assuming a linear connection between the load and the dynamic response amplitudes. However, while generally valuable, the precision losses associated with large load variations may mask the contribution of tiny flaws. To better reflect the real non-linear relation, the paper reformulates the scaling factor; a power law with an exponent value of 0.85 produces noticeable improvements of the load effect extraction. To reduce the consequences of remaining oscillations, the procedure also includes a filtering phase. During the validation program, a synthetic wear progression assuming a commensurate relation between the wear depth and friction assured controlled evolutions of the surface degradation influence, whereas the fillet crack growth remained entirely determined by the operation conditions. Globally, the tested conditions attest that the final strategy provides accurate monitoring of coexisting isolated damages and general surface deterioration, and that its tracking-detection capacities are unaffected by severe time variations of external loads. The procedure promptly detects the presence of evolving abnormal phenomena. The tests show that the descriptor curve shapes virtually describe the constant wear progression superimposed on the crack length evolution. At the tooth fracture, the mean values of

  3. Dynamical correction of control laws for marine ships' accurate steering

    NASA Astrophysics Data System (ADS)

    Veremey, Evgeny I.

    2014-06-01

    The objective of this work is the analytical synthesis problem for marine vehicles autopilots design. Despite numerous known methods for a solution, the mentioned problem is very complicated due to the presence of an extensive population of certain dynamical conditions, requirements and restrictions, which must be satisfied by the appropriate choice of a steering control law. The aim of this paper is to simplify the procedure of the synthesis, providing accurate steering with desirable dynamics of the control system. The approach proposed here is based on the usage of a special unified multipurpose control law structure that allows decoupling a synthesis into simpler particular optimization problems. In particular, this structure includes a dynamical corrector to support the desirable features for the vehicle's motion under the action of sea wave disturbances. As a result, a specialized new method for the corrector design is proposed to provide an accurate steering or a trade-off between accurate steering and economical steering of the ship. This method guaranties a certain flexibility of the control law with respect to an actual environment of the sailing; its corresponding turning can be realized in real time onboard.

  4. Accurate and simple calibration of DLP projector systems

    NASA Astrophysics Data System (ADS)

    Wilm, Jakob; Olesen, Oline V.; Larsen, Rasmus

    2014-03-01

    Much work has been devoted to the calibration of optical cameras, and accurate and simple methods are now available which require only a small number of calibration targets. The problem of obtaining these parameters for light projectors has not been studied as extensively and most current methods require a camera and involve feature extraction from a known projected pattern. In this work we present a novel calibration technique for DLP Projector systems based on phase shifting profilometry projection onto a printed calibration target. In contrast to most current methods, the one presented here does not rely on an initial camera calibration, and so does not carry over the error into projector calibration. A radial interpolation scheme is used to convert features coordinates into projector space, thereby allowing for a very accurate procedure. This allows for highly accurate determination of parameters including lens distortion. Our implementation acquires printed planar calibration scenes in less than 1s. This makes our method both fast and convenient. We evaluate our method in terms of reprojection errors and structured light image reconstruction quality.

  5. Principles of plasma diagnostics

    NASA Astrophysics Data System (ADS)

    Hutchinson, Ian H.

    The physical principles, techniques, and instrumentation of plasma diagnostics are examined in an introduction and reference work for students and practicing scientists. Topics addressed include basic plasma properties, magnetic diagnostics, plasma particle flux, and refractive-index measurements. Consideration is given to EM emission by free and bound electrons, the scattering of EM radiation, and ion processes. Diagrams, drawings, graphs, sample problems, and a glossary of symbols are provided.

  6. Laser fluorescence diagnostics

    NASA Astrophysics Data System (ADS)

    Kozlov, V. K.; Krasilnikov, D. M.; Turkin, V. V.

    1995-01-01

    This paper descsribes the development of an apparatus, method, and practical recommendation on using fluorescence diagnostics in alimentary-intestinal tract surgery and analyses of blood serum and plasma for investigating influence of various drug preparations on a human organism. The report of the firm Israel Aircraft Industries on the high efficiency of using fluorescent analysis in early diagnostics of rectum, lung, and breast cancer has stimulated our publication.

  7. Accurate Molecular Dimensions from Stearic Acid Monolayers.

    ERIC Educational Resources Information Center

    Lane, Charles A.; And Others

    1984-01-01

    Discusses modifications in the fatty acid monolayer experiment to reduce the inaccurate moleculary data students usually obtain. Copies of the experimental procedure used and a Pascal computer program to work up the data are available from the authors. (JN)

  8. Needle track seeding following percutaneous procedures for hepatocellular carcinoma

    PubMed Central

    Cabibbo, Giuseppe; Craxì, Antonio

    2009-01-01

    Neoplastic seeding may arise after diagnostic or therapeutic percutaneous procedures for hepatocellular carcinoma. The true incidence of seeding with hepatocellular carcinoma is difficult to assess precisely, but a significant risk of seeding exists and is greater when performing diagnostic biopsy as compared to therapeutic percutaneous procedures [radiofrequency ablation, radiofrequency ablation (RFA); percutaneous ethanol injection, Percutaneous ethanol injection (PEI)]. Whenever liver transplantation is feasible, diagnostic needle biopsies should be avoided, but RFA and PEI are often needed as “bridge” treatments. The role of adjuvant treatments in reducing the incidence of seeding following RFA or PEI requires further evaluation. PMID:21160966

  9. A robust and accurate formulation of molecular and colloidal electrostatics.

    PubMed

    Sun, Qiang; Klaseboer, Evert; Chan, Derek Y C

    2016-08-07

    This paper presents a re-formulation of the boundary integral method for the Debye-Hückel model of molecular and colloidal electrostatics that removes the mathematical singularities that have to date been accepted as an intrinsic part of the conventional boundary integral equation method. The essence of the present boundary regularized integral equation formulation consists of subtracting a known solution from the conventional boundary integral method in such a way as to cancel out the singularities associated with the Green's function. This approach better reflects the non-singular physical behavior of the systems on boundaries with the benefits of the following: (i) the surface integrals can be evaluated accurately using quadrature without any need to devise special numerical integration procedures, (ii) being able to use quadratic or spline function surface elements to represent the surface more accurately and the variation of the functions within each element is represented to a consistent level of precision by appropriate interpolation functions, (iii) being able to calculate electric fields, even at boundaries, accurately and directly from the potential without having to solve hypersingular integral equations and this imparts high precision in calculating the Maxwell stress tensor and consequently, intermolecular or colloidal forces, (iv) a reliable way to handle geometric configurations in which different parts of the boundary can be very close together without being affected by numerical instabilities, therefore potentials, fields, and forces between surfaces can be found accurately at surface separations down to near contact, and (v) having the simplicity of a formulation that does not require complex algorithms to handle singularities will result in significant savings in coding effort and in the reduction of opportunities for coding errors. These advantages are illustrated using examples drawn from molecular and colloidal electrostatics.

  10. A robust and accurate formulation of molecular and colloidal electrostatics

    NASA Astrophysics Data System (ADS)

    Sun, Qiang; Klaseboer, Evert; Chan, Derek Y. C.

    2016-08-01

    This paper presents a re-formulation of the boundary integral method for the Debye-Hückel model of molecular and colloidal electrostatics that removes the mathematical singularities that have to date been accepted as an intrinsic part of the conventional boundary integral equation method. The essence of the present boundary regularized integral equation formulation consists of subtracting a known solution from the conventional boundary integral method in such a way as to cancel out the singularities associated with the Green's function. This approach better reflects the non-singular physical behavior of the systems on boundaries with the benefits of the following: (i) the surface integrals can be evaluated accurately using quadrature without any need to devise special numerical integration procedures, (ii) being able to use quadratic or spline function surface elements to represent the surface more accurately and the variation of the functions within each element is represented to a consistent level of precision by appropriate interpolation functions, (iii) being able to calculate electric fields, even at boundaries, accurately and directly from the potential without having to solve hypersingular integral equations and this imparts high precision in calculating the Maxwell stress tensor and consequently, intermolecular or colloidal forces, (iv) a reliable way to handle geometric configurations in which different parts of the boundary can be very close together without being affected by numerical instabilities, therefore potentials, fields, and forces between surfaces can be found accurately at surface separations down to near contact, and (v) having the simplicity of a formulation that does not require complex algorithms to handle singularities will result in significant savings in coding effort and in the reduction of opportunities for coding errors. These advantages are illustrated using examples drawn from molecular and colloidal electrostatics.

  11. Accurately Diagnosing and Treating Borderline Personality Disorder

    PubMed Central

    Gentile, Julie P.; Correll, Terry L.

    2010-01-01

    The high prevalence of comorbid bipolar and borderline personality disorders and some diagnostic criteria similar to both conditions present both diagnostic and therapeutic challenges. This article delineates certain symptoms which, by careful history taking, may be attributed more closely to one of these two disorders. Making the correct primary diagnosis along with comorbid psychiatric conditions and choosing the appropriate type of psychotherapy and pharmacotherapy are critical steps to a patient's recovery. In this article, we will use a case example to illustrate some of the challenges the psychiatrist may face in diagnosing and treating borderline personality disorder. In addition, we will explore treatment strategies, including various types of therapy modalities and medication classes, which may prove effective in stabilizing or reducing a broad range of symptomotology associated with borderline personality disorder. PMID:20508805

  12. Diagnostic Flow Metering using Ultrasound Tomography

    NASA Astrophysics Data System (ADS)

    Chun, Sejong; Yoon, Byung-Ro; Lee, Kwang-Bock; Paik, Jong-Seung

    2010-06-01

    Flow meters, which are used for transferring water or crude oil through pipelines, require well-defined flow conditions for accurate flow rate monitoring. Even though all the installation conditions for the flow meters are satisfied, there could be unexpected flow disturbances, such as abrupt increase of upstream pressure, affecting on the performance of flow meters. To investigate any differences between measured and actual flow rates, flow velocity profiles inside the pipeline must be known. Ultrasound tomography is a means of reconstructing flow profiles from line-averaged velocities by Radon transformation. Diagnostic parameters are then extracted from the reconstructed flow profiles to give information whether the flow conditions are appropriate for accurate flow metering. In the present study, flow profiles downstream of a mass flow meter and a butterfly valve are reconstructed. Flow diagnostic parameters are defined using statistical moments such as mean value, standard deviation, skewness and kurtosis. The measured diagnostic parameters in the above-mentioned flow conditions are compared with those of fully-developed laminar and turbulent flow profiles to validate their usefulness.

  13. Diagnostic approach to the congenital muscular dystrophies

    PubMed Central

    Bönnemann, Carsten G.; Wang, Ching H.; Quijano-Roy, Susana; Deconinck, Nicolas; Bertini, Enrico; Ferreiro, Ana; Muntoni, Francesco; Sewry, Caroline; Béroud, Christophe; Mathews, Katherine D.; Moore, Steven A.; Bellini, Jonathan; Rutkowski, Anne; North, Kathryn N.

    2017-01-01

    Congenital muscular dystrophies (CMDs) are early onset disorders of muscle with histological features suggesting a dystrophic process. The congenital muscular dystrophies as a group encompass great clinical and genetic heterogeneity so that achieving an accurate genetic diagnosis has become increasingly challenging, even in the age of next generation sequencing. In this document we review the diagnostic features, differential diagnostic considerations and available diagnostic tools for the various CMD subtypes and provide a systematic guide to the use of these resources for achieving an accurate molecular diagnosis. An International Committee on the Standard of Care for Congenital Muscular Dystrophies composed of experts on various aspects relevant to the CMDs performed a review of the available literature as well as of the unpublished expertise represented by the members of the committee and their contacts. This process was refined by two rounds of online surveys and followed by a three-day meeting at which the conclusions were presented and further refined. The combined consensus summarized in this document allows the physician to recognize the presence of a CMD in a child with weakness based on history, clinical examination, muscle biopsy results, and imaging. It will be helpful in suspecting a specific CMD subtype in order to prioritize testing to arrive at a final genetic diagnosis. PMID:24581957

  14. Advanced smile diagnostics using CAD/CAM mock-ups.

    PubMed

    Sancho-Puchades, Manuel; Fehmer, Vincent; Hämmerle, Christoph; Sailer, Irena

    2015-01-01

    Diagnostics are essential for predictable restorative dentistry. Both patient and clinician must agree on a treatment goal before the final restorations are delivered to avoid future disappointments. However, fully understanding the patient's desires is difficult. A useful tool to overcome this problem is the diagnostic wax-up and mock-up. A potential treatment outcome is modeled in wax prior to treatment and transferred into the patient's mouth using silicon indexes and autopolymerizing resin to obtain the patient's approval. Yet, this time-consuming procedure only produces a single version of the possible treatment outcome, which can be unsatisfactory for both the patient and the restorative team. Contemporary digital technologies may provide advantageous features to aid in this diagnostic treatment step. This article reviews opportunities digital technologies offer in the diagnostic phase, and presents clinical cases to illustrate the procedures.

  15. Revisiting Tversky's diagnosticity principle

    PubMed Central

    Evers, Ellen R. K.; Lakens, Daniël

    2013-01-01

    Similarity is a fundamental concept in cognition. In 1977, Amos Tversky published a highly influential feature-based model of how people judge the similarity between objects. The model highlights the context-dependence of similarity judgments, and challenged geometric models of similarity. One of the context-dependent effects Tversky describes is the diagnosticity principle. The diagnosticity principle determines which features are used to cluster multiple objects into subgroups. Perceived similarity between items within clusters is expected to increase, while similarity between items in different clusters decreases. Here, we present two pre-registered replications of the studies on the diagnosticity effect reported in Tversky (1977). Additionally, one alternative mechanism that has been proposed to play a role in the original studies, an increase in the choice for distractor items (a substitution effect, see Medin et al., 1995), is examined. Our results replicate those found by Tversky (1977), revealing an average diagnosticity-effect of 4.75%. However, when we eliminate the possibility of substitution effects confounding the results, a meta-analysis of the data provides no indication of any remaining effect of diagnosticity. PMID:25161638

  16. Development of companion diagnostics

    SciTech Connect

    Mankoff, David A.; Edmonds, Christine E.; Farwell, Michael D.; Pryma, Daniel A.

    2015-12-12

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient’s cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has “hit” the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2–targeted therapy. Lastly, the review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.

  17. Development of companion diagnostics

    DOE PAGES

    Mankoff, David A.; Edmonds, Christine E.; Farwell, Michael D.; ...

    2015-12-12

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient’s cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods asmore » companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has “hit” the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2–targeted therapy. Lastly, the review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.« less

  18. Development of Companion Diagnostics.

    PubMed

    Mankoff, David A; Edmonds, Christine E; Farwell, Michael D; Pryma, Daniel A

    2016-01-01

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient's cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has "hit" the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2-targeted therapy. The review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.

  19. MJO Simulation Diagnostics

    SciTech Connect

    Waliser, D; Sperber, K; Hendon, H; Kim, D; Maloney, E; Wheeler, M; Weickmann, K; Zhang, C; Donner, L; Gottschalck, J; Higgins, W; Kang, I; Legler, D; Moncrieff, M; Schubert, S; Stern, W; Vitart, F; Wang, B; Wang, W; Woolnough, S

    2008-06-02

    The Madden-Julian Oscillation (MJO) interacts with, and influences, a wide range of weather and climate phenomena (e.g., monsoons, ENSO, tropical storms, mid-latitude weather), and represents an important, and as yet unexploited, source of predictability at the subseasonal time scale. Despite the important role of the MJO in our climate and weather systems, current global circulation models (GCMs) exhibit considerable shortcomings in representing this phenomenon. These shortcomings have been documented in a number of multi-model comparison studies over the last decade. However, diagnosis of model performance has been challenging, and model progress has been difficult to track, due to the lack of a coherent and standardized set of MJO diagnostics. One of the chief objectives of the US CLIVAR MJO Working Group is the development of observation-based diagnostics for objectively evaluating global model simulations of the MJO in a consistent framework. Motivation for this activity is reviewed, and the intent and justification for a set of diagnostics is provided, along with specification for their calculation, and illustrations of their application. The diagnostics range from relatively simple analyses of variance and correlation, to more sophisticated space-time spectral and empirical orthogonal function analyses. These diagnostic techniques are used to detect MJO signals, to construct composite life-cycles, to identify associations of MJO activity with the mean state, and to describe interannual variability of the MJO.

  20. Accurate pointing of tungsten welding electrodes

    NASA Technical Reports Server (NTRS)

    Ziegelmeier, P.

    1971-01-01

    Thoriated-tungsten is pointed accurately and quickly by using sodium nitrite. Point produced is smooth and no effort is necessary to hold the tungsten rod concentric. The chemically produced point can be used several times longer than ground points. This method reduces time and cost of preparing tungsten electrodes.

  1. Diagnostic accuracies of clinical studies in patients with small cell carcinoma of the lung

    SciTech Connect

    Chak, L.Y.; Paryani, S.B.; Sikic, B.I.; Lockbaum, P.; Torti, F.M.; Carter, S.K.

    1983-05-01

    The diagnostic accuracy of clinical studies done in 38 patients with small cell carcinoma of the lung was analyzed by comparing the test results to autopsy findings. The chest radiograph was accurate in 31 of 38 patients (82%). The accuracy of the chest radiograph was higher in evaluating the lung parenchyma and mediastinum than in evaluating the hilum and pleura. Computerized tomographic brain scan was accurate in 11 of 12 patients. However, all the diagnostic studies used for assessing the liver, including physical examination, serum liver enzyme and bilirubin measurements, and radionuclide liver scan, were only moderately accurate. More accurate studies for detecting liver metastasis in patients with small cell carcinoma are needed.

  2. Recent improvements of the JET lithium beam diagnostic

    SciTech Connect

    Brix, M.; Morgan, P.; Stamp, M.; Zastrow, K.-D.; Dunai, D.; Meszaros, B.; Petravich, G.; Refy, D. I.; Szabolics, T.; Zoletnik, S.; Lupelli, I.; Marsen, S.; Melson, T. F.; Silva, C. [EURATOM Collaboration: JET-EFDA Contributors

    2012-10-15

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  3. MO-DE-304-02: Diagnostic Workforce Subcommittee Status and Direction

    SciTech Connect

    Gress, D.

    2015-06-15

    The Abt study of medical physicist work values for radiation oncology physics services, Round IV is completed. It supersedes the Abt III study of 2008. The 2015 Abt study measured qualified medical physicist (QMP) work associated with routine radiation oncology procedures as well as some special procedures. As before, a work model was created to allow the medical physicist to defend QMP work based on both routine and special procedures service mix. The work model can be used to develop a cost justification report for setting charges for radiation oncology physics services. The Abt study Round IV was designed to empower the medical physicist to negotiate a service or employment contract with providers based on measured national QMP workforce and staffing data. For a variety of reasons, the diagnostic imaging contingent of AAPM has had a more difficult time trying estimate workforce requirements than their therapy counterparts. Over the past several years, the Diagnostic Work and Workforce Study Subcommittee (DWWSS) has collected survey data from AAPM members, but the data have been very difficult to interpret. The DWWSS has reached out to include more AAPM volunteers to create a more full and accurate representation of actual clinical practice models on the subcommittee. Though much work remains, through hours of discussion and brainstorming, the DWWSS has somewhat of a clear path forward. This talk will provide attendees with an update on the efforts of the subcommittee. Learning Objectives: Understand the new information documented in the Abt studies. Understand how to use the Abt studies to justify medical physicist staffing. Learn relevant historical information on imaging physicist workforce. Understand the process of the DWWSS in 2014. Understand the intended path forward for the DWWSS.

  4. [Peripheral neuropathies: Diagnostic strategy].

    PubMed

    Magy, L

    2017-02-28

    Diagnosing a peripheral neuropathy is sometimes challenging, as the causes are diverse and the clinical pictures heterogeneous. Overall, diagnosing a patient with peripheral neuropathy will require some knowledge in almost every field of medicine. Therefore, it appears crucial to adopt a diagnostic strategy that is based on solid clinical and neurophysiological grounds. The present paper describes a three-step diagnostic strategy: (1) to delineate a clinico-pathologic entity from clinical and electrodiagnostic findings; (2) to propose a list of plausible causes based on step one, history and clinical context; (3) to use appropriate workup in order to determine the cause or mechanism of the neuropathy. The three steps of this diagnostic strategy necessitate a high level of expertise and interaction between physicians is highly desirable. Finally, an aggressive course and a severe impairment should lead to relentlessly look for a curable cause.

  5. [Molecular diagnostics in pathology].

    PubMed

    Stenzinger, A; Penzel, R; Endris, V; Weichert, W

    2013-05-01

    Tissue-based molecular diagnostics is a fast growing diagnostic field, which already complements morphologic classifications in many cases. Pathology based molecular diagnosis is performed almost exclusively on paraffin embedded material and always in conjunction with histopathology. Besides the classic field of tissue based detection of pathogenic organisms such as bacteria, viruses and fungi, molecular diagnostics of tumor tissue is one of the current hot topics in oncology. In this context the detection of predictive molecular biomarkers, such as specific mutations, allows patient stratification for individually tailored treatment strategies and thereby is one of the key components of individualized patient care in oncology. The rapidly growing number of clinically relevant predictive biomarkers together with impressive technical advances, specifically the development of massive parallel sequencing, will modify the care of patients with malignant diseases. Pathology, therefore, has returned in the very center of interdisciplinary patient care.

  6. ORION laser target diagnostics.

    PubMed

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  7. Automatic Generation of Conditional Diagnostic Guidelines.

    PubMed

    Baldwin, Tyler; Guo, Yufan; Syeda-Mahmood, Tanveer

    2016-01-01

    The diagnostic workup for many diseases can be extraordinarily nuanced, and as such reference material text often contains extensive information regarding when it is appropriate to have a patient undergo a given procedure. In this work we employ a three task pipeline for the extraction of statements indicating the conditions under which a procedure should be performed, given a suspected diagnosis. First, we identify each instance in the text where a procedure is being recommended. Next we examine the context around these recommendations to extract conditional statements that dictate the conditions under which the recommendation holds. Finally, corefering recommendations across the document are linked to produce a full recommendation summary. Results indicate that each underlying task can be performed with above baseline performance, and the output can be used to produce concise recommendation summaries.

  8. Automatic Generation of Conditional Diagnostic Guidelines

    PubMed Central

    Baldwin, Tyler; Guo, Yufan; Syeda-Mahmood, Tanveer

    2016-01-01

    The diagnostic workup for many diseases can be extraordinarily nuanced, and as such reference material text often contains extensive information regarding when it is appropriate to have a patient undergo a given procedure. In this work we employ a three task pipeline for the extraction of statements indicating the conditions under which a procedure should be performed, given a suspected diagnosis. First, we identify each instance in the text where a procedure is being recommended. Next we examine the context around these recommendations to extract conditional statements that dictate the conditions under which the recommendation holds. Finally, corefering recommendations across the document are linked to produce a full recommendation summary. Results indicate that each underlying task can be performed with above baseline performance, and the output can be used to produce concise recommendation summaries. PMID:28269823

  9. Bariatric Surgery Procedures

    MedlinePlus

    ... Center Access to Care Toolkit EHB Access Toolkit Bariatric Surgery Procedures Bariatric surgical procedures cause weight loss by ... minimally invasive techniques (laparoscopic surgery). The most common bariatric surgery procedures are gastric bypass, sleeve gastrectomy, adjustable gastric ...

  10. [Complex diagnostics of osteosarcomas].

    PubMed

    Muradov, Kh K; Sadykhova, G G

    2014-01-01

    It was analyzed the examination results of 156 patients with osteosarcoma. The data show that definition of histogenetic source, diagnostics and prognosis of treatment results are possible and expedient in case of analysis of signs reflecting tumor cells specificity. These signs may be determined by using of clinical parameters, X-ray imaging and light microscopy in case of moderately and highly differentiated sarcomas. Ample opportunities of flow citometry and immunohistochemistry allow to perform histogenetic identification, differential diagnostics and prognosis for low-grade sarcomas.

  11. Feedback about More Accurate versus Less Accurate Trials: Differential Effects on Self-Confidence and Activation

    ERIC Educational Resources Information Center

    Badami, Rokhsareh; VaezMousavi, Mohammad; Wulf, Gabriele; Namazizadeh, Mahdi

    2012-01-01

    One purpose of the present study was to examine whether self-confidence or anxiety would be differentially affected by feedback from more accurate rather than less accurate trials. The second purpose was to determine whether arousal variations (activation) would predict performance. On Day 1, participants performed a golf putting task under one of…

  12. Molecular diagnostic assays for cervical neoplasia: emerging markers for the detection of high-grade cervical disease.

    PubMed

    Malinowski, Douglas P

    2005-04-01

    The accurate detection and diagnosis of cervical carcinoma and its malignant precursors (collectively referred to as high-grade cervical disease) represents one of the current challenges in clinical medicine and cytopathology. The advent of molecular diagnostics and the use of whole-genome profiling using DNA microarrays promises to yield improved understanding of the disease process with the subsequent development of more accurate diagnostic procedures based upon these discoveries. Recent reports describing a variety of experimental approaches have identified a series of candidate genes that are overexpressed in cervical carcinoma. In this article, representative examples of these markers and the resulting translational research will be reviewed within the context of improved cervical disease detection. An emerging class of markers, the minichromosome maintenance protein family of DNA licensing factors (MCM-2, MCM-6, MCM-7), shows promise for the specific detection of high-grade cervical disease using simple antibody-based immunochemistry formats. These proteins are overexpressed in cervical disease as a result of infection by oncogenic strains of human papillomavirus (HPV) and subsequent uncontrolled activation of gene transcription and aberrant S-phase induction, mediated through the E2F transcription factor pathway. This behavior appears to be a hallmark of high-grade cervical disease and provides the link between oncogenic HPV infections and the molecular behavior of cervical neoplasia (CN). The use of these molecular descriptors of CN in simple immunochemistry formats compatible with conventional cytology preparations is anticipated to improve the screening and detection of cervical disease within the healthcare system.

  13. Training in Structured Diagnostic Assessment Using DSM-IV Criteria

    ERIC Educational Resources Information Center

    Ponniah, Kathryn; Weissman, Myrna M.; Bledsoe, Sarah E.; Verdeli, Helen; Gameroff, Marc J.; Mufson, Laura; Fitterling, Heidi; Wickramaratne, Priya

    2011-01-01

    Objectives: Determining a patient's psychiatric diagnosis is an important first step for the selection of empirically supported treatments and a critical component of evidence-based practice. Structured diagnostic assessment covers the range of psychiatric diagnoses and is usually more complete and accurate than unstructured assessment. Method: We…

  14. Enhancing ADHD and LD Diagnostic Accuracy Using Career Instruments

    ERIC Educational Resources Information Center

    Dipeolu, Abiola; Hargrave, Stephanie; Storlie, Cassandra A.

    2015-01-01

    Individuals diagnosed with mental health disorders may have work-related difficulties that impact functioning in all life domains. With limited research on the integration of career and mental health counseling, authors used a discriminant function analysis to assess the predictability of accurately identifying diagnostic categories among 258…

  15. Viral diagnostics: will new technology save the day

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Technology for infectious agent detection continues to evolve, particularly molecular methods which first emerged in the mid-1970’s. The goals of new technology in diagnostics are to achieve the highest sensitivity and specificity possible to accurately identify the infection status of an individua...

  16. [Enuresis and pediatric urinary incontinence : Diagnostics and therapy].

    PubMed

    Schultz-Lampel, D; Goepel, M; Reitz, A; Braun, P

    2016-12-01

    Differentiated non-invasive diagnostic procedures allow a discrimination between nocturnal enuresis and behavior-linked urinary incontinence in children with daytime symptoms, which are different entities of a pathological pediatric micturition syndrome. The article describes the diagnostic procedure as well as the therapeutic approach to all forms of micturition disorders in childhood. All behavioral, medical and biofeedback therapeutic methods according to the recently published S2k guidelines from the Association of the Scientific Medical Societies in Germany (AWMF) on enuresis and non-organic (functional) incontinence in children and adolescents are mentioned and discussed.

  17. Accurate Anisotropic Fast Marching for Diffusion-Based Geodesic Tractography

    PubMed Central

    Jbabdi, S.; Bellec, P.; Toro, R.; Daunizeau, J.; Pélégrini-Issac, M.; Benali, H.

    2008-01-01

    Using geodesics for inferring white matter fibre tracts from diffusion-weighted MR data is an attractive method for at least two reasons: (i) the method optimises a global criterion, and hence is less sensitive to local perturbations such as noise or partial volume effects, and (ii) the method is fast, allowing to infer on a large number of connexions in a reasonable computational time. Here, we propose an improved fast marching algorithm to infer on geodesic paths. Specifically, this procedure is designed to achieve accurate front propagation in an anisotropic elliptic medium, such as DTI data. We evaluate the numerical performance of this approach on simulated datasets, as well as its robustness to local perturbation induced by fiber crossing. On real data, we demonstrate the feasibility of extracting geodesics to connect an extended set of brain regions. PMID:18299703

  18. Robust and Accurate Seismic(acoustic) Ray Tracer

    NASA Astrophysics Data System (ADS)

    Debski, W.; Ando, M.

    Recent development of high resolution seismic tomography as well as a need for a high precision seismic (acoustic) source locations calls for robust and very precise numeri- cal methods of an estimation of seismic (acoustic) travel times and ray paths. Here we present a method based on a parametrisation of the ray path by a series of the Cheby- shev polynomials. This pseudo-spectral method, combined with the accurate Gauss- Lobbato integration procedure allows to reach a very high relative travel time accu- racy t/t 10-7. At the same time use of the Genetic Algorithm based optimizer (Evolutionary Algorithm) assures an extreme robustness which allows the method to be used in complicated 3D geological structures like multi-fault areas, mines, or real engineering applications, constructions, etc.

  19. An Inexpensive and Accurate Tensiometer Using an Electronic Balance

    NASA Astrophysics Data System (ADS)

    Dolz, Manuel; Delegido, Jesús; Hernández, María-Jesús; Pellicer, Julio

    2001-09-01

    A method for measuring surface tension of liquid-air interfaces that consists of a modification of the du Noüy tensiometer is proposed. An electronic balance is used to determine the detachment force with high resolution and the relative displacement ring/plate-liquid surface is carried out by the descent of the liquid-free surface. The procedure familiarizes undergraduate students in applied science and technology with the experimental study of surface tension by means of a simple and accurate method that offers the advantages of sophisticated devices at considerably less cost. The operational aspects that must be taken into account are analyzed: the measuring system and determination of its effective length, measurement of the detachment force, and the relative system-liquid interface displacement rate. To check the accuracy of the proposed tensiometer, measurements of the surface tension of different known liquids have been performed, and good agreement with results reported in the literature was obtained.

  20. Accurate Guitar Tuning by Cochlear Implant Musicians

    PubMed Central

    Lu, Thomas; Huang, Juan; Zeng, Fan-Gang

    2014-01-01

    Modern cochlear implant (CI) users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task. PMID:24651081

  1. New model accurately predicts reformate composition

    SciTech Connect

    Ancheyta-Juarez, J.; Aguilar-Rodriguez, E. )

    1994-01-31

    Although naphtha reforming is a well-known process, the evolution of catalyst formulation, as well as new trends in gasoline specifications, have led to rapid evolution of the process, including: reactor design, regeneration mode, and operating conditions. Mathematical modeling of the reforming process is an increasingly important tool. It is fundamental to the proper design of new reactors and revamp of existing ones. Modeling can be used to optimize operating conditions, analyze the effects of process variables, and enhance unit performance. Instituto Mexicano del Petroleo has developed a model of the catalytic reforming process that accurately predicts reformate composition at the higher-severity conditions at which new reformers are being designed. The new AA model is more accurate than previous proposals because it takes into account the effects of temperature and pressure on the rate constants of each chemical reaction.

  2. Accurate colorimetric feedback for RGB LED clusters

    NASA Astrophysics Data System (ADS)

    Man, Kwong; Ashdown, Ian

    2006-08-01

    We present an empirical model of LED emission spectra that is applicable to both InGaN and AlInGaP high-flux LEDs, and which accurately predicts their relative spectral power distributions over a wide range of LED junction temperatures. We further demonstrate with laboratory measurements that changes in LED spectral power distribution with temperature can be accurately predicted with first- or second-order equations. This provides the basis for a real-time colorimetric feedback system for RGB LED clusters that can maintain the chromaticity of white light at constant intensity to within +/-0.003 Δuv over a range of 45 degrees Celsius, and to within 0.01 Δuv when dimmed over an intensity range of 10:1.

  3. Accurate guitar tuning by cochlear implant musicians.

    PubMed

    Lu, Thomas; Huang, Juan; Zeng, Fan-Gang

    2014-01-01

    Modern cochlear implant (CI) users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼ 30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task.

  4. An Accurate, Simplified Model Intrabeam Scattering

    SciTech Connect

    Bane, Karl LF

    2002-05-23

    Beginning with the general Bjorken-Mtingwa solution for intrabeam scattering (IBS) we derive an accurate, greatly simplified model of IBS, valid for high energy beams in normal storage ring lattices. In addition, we show that, under the same conditions, a modified version of Piwinski's IBS formulation (where {eta}{sub x,y}{sup 2}/{beta}{sub x,y} has been replaced by {Eta}{sub x,y}) asymptotically approaches the result of Bjorken-Mtingwa.

  5. An accurate registration technique for distorted images

    NASA Technical Reports Server (NTRS)

    Delapena, Michele; Shaw, Richard A.; Linde, Peter; Dravins, Dainis

    1990-01-01

    Accurate registration of International Ultraviolet Explorer (IUE) images is crucial because the variability of the geometrical distortions that are introduced by the SEC-Vidicon cameras ensures that raw science images are never perfectly aligned with the Intensity Transfer Functions (ITFs) (i.e., graded floodlamp exposures that are used to linearize and normalize the camera response). A technique for precisely registering IUE images which uses a cross correlation of the fixed pattern that exists in all raw IUE images is described.

  6. On accurate determination of contact angle

    NASA Technical Reports Server (NTRS)

    Concus, P.; Finn, R.

    1992-01-01

    Methods are proposed that exploit a microgravity environment to obtain highly accurate measurement of contact angle. These methods, which are based on our earlier mathematical results, do not require detailed measurement of a liquid free-surface, as they incorporate discontinuous or nearly-discontinuous behavior of the liquid bulk in certain container geometries. Physical testing is planned in the forthcoming IML-2 space flight and in related preparatory ground-based experiments.

  7. Studies and analyses of the Space Shuttle Main Engine: SSME failure data review, diagnostic survey and SSME diagnostic evaluation

    NASA Technical Reports Server (NTRS)

    Glover, R. C.; Kelley, B. A.; Tischer, A. E.

    1986-01-01

    The results of a review of the Space Shuttle Main Engine (SSME) failure data for the period 1980 through 1983 are presented. The data was collected, evaluated, and ranked according to procedures established during this study. A number of conclusions and recommendations are made based upon this failure data review. The results of a state-of-the-art diagnostic survey are also presented. This survey covered a broad range of diagnostic sensors and techniques and the findings were evaluated for application to the SSME. Finally, a discussion of the initial activities for the on-going SSME diagnostic evaluation is included.

  8. A procedural analysis of correspondence training techniques

    PubMed Central

    Paniagua, Freddy A.

    1990-01-01

    A variety of names have been given to procedures used in correspondence training, some more descriptive than others. In this article I argue that a terminology more accurately describing actual procedures, rather than the conceptual function that those procedures are assumed to serve, would benefit the area of correspondence training. I identify two documented procedures during the reinforcement of verbalization phase and five procedures during the reinforcement of correspondence phase and suggest that those procedures can be classified, or grouped into nonoverlapping categories, by specifying the critical dimensions of those procedures belonging to a single category. I suggest that the names of such nonoverlapping categories should clearly specify the dimensions on which the classification is based in order to facilitate experimental comparison of procedures, and to be able to recognize when a new procedure (as opposed to a variant of one already in existence) is developed. Future research involving comparative analysis across and within procedures is discussed within the framework of the proposed classification. PMID:22478059

  9. Equivalent Diagnostic Classification Models

    ERIC Educational Resources Information Center

    Maris, Gunter; Bechger, Timo

    2009-01-01

    Rupp and Templin (2008) do a good job at describing the ever expanding landscape of Diagnostic Classification Models (DCM). In many ways, their review article clearly points to some of the questions that need to be answered before DCMs can become part of the psychometric practitioners toolkit. Apart from the issues mentioned in this article that…

  10. Sexual Addiction: Diagnostic Problems

    ERIC Educational Resources Information Center

    Giugliano, John R.

    2009-01-01

    In recent years clinicians report a great deal of concern about definition, diagnostic assessment, and treatment modalities when dealing with what might be called out-of-control sexual behavior. Many terms have been used to describe the phenomenon of problematic sexual behavior. Many of these concepts overlap, some are no longer popular, and some…

  11. Rocket Engine Oscillation Diagnostics

    NASA Technical Reports Server (NTRS)

    Nesman, Tom; Turner, James E. (Technical Monitor)

    2002-01-01

    Rocket engine oscillating data can reveal many physical phenomena ranging from unsteady flow and acoustics to rotordynamics and structural dynamics. Because of this, engine diagnostics based on oscillation data should employ both signal analysis and physical modeling. This paper describes an approach to rocket engine oscillation diagnostics, types of problems encountered, and example problems solved. Determination of design guidelines and environments (or loads) from oscillating phenomena is required during initial stages of rocket engine design, while the additional tasks of health monitoring, incipient failure detection, and anomaly diagnostics occur during engine development and operation. Oscillations in rocket engines are typically related to flow driven acoustics, flow excited structures, or rotational forces. Additional sources of oscillatory energy are combustion and cavitation. Included in the example problems is a sampling of signal analysis tools employed in diagnostics. The rocket engine hardware includes combustion devices, valves, turbopumps, and ducts. Simple models of an oscillating fluid system or structure can be constructed to estimate pertinent dynamic parameters governing the unsteady behavior of engine systems or components. In the example problems it is shown that simple physical modeling when combined with signal analysis can be successfully employed to diagnose complex rocket engine oscillatory phenomena.

  12. Tele diagnostic by web

    NASA Astrophysics Data System (ADS)

    Sugiyama, Shigeki

    2006-03-01

    Because of the development of multimedia technologies like Web and Internet, it now becomes possible to think about Tele Medicine and Tele Diagnostic for a distant place where no doctors and no nurses are situated at or are available. And also some kind of intelligence can be added onto them, which makes possible to give certain kind of medical treatment assistance or suggestions for a patient from a computer diagnostic base through the Internetworking. For doing this, here considers about a basic system of "Tele Diagnostic for a remote place" where it dose not have a doctor and a medical assistance. In order to implement the system, JAVA, VRML, HTML, and CORTONA are used as a basic language and a viewer. And also in order to add a kind of intelligence, Augmented Knowledge In Agent (AKIA) by using Back Propagation Neural Networks (BPNN) is used. And by this study, here can introduce the system that has the following basic mechanisms; By inputting physical data like temperature or blood pressure, the system would show a diagnostic assistance by TEXT. And also the bad place of body would be shown graphically if there were any. The system can be put onto Web, so that anybody could have this assistance at any place ubiquitously only if a person has Internetworking access.

  13. ESPC Integrated Skill Diagnostics

    DTIC Science & Technology

    2015-09-30

    monitoring systems for gauging performance of the ESPC. This is an integral part of the overall ESPC goal of developing a global coupled system between...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. ESPC Integrated Skill Diagnostics Maria Flatau Naval...quantitative skill metrics to assess the advancements in the Earth System Prediction Capability (ESPC). This work will also implement automated

  14. Diagnostic peritoneal lavage - slideshow

    MedlinePlus

    ... Indication URL of this page: //medlineplus.gov/ency/presentations/100159.htm Diagnostic peritoneal lavage - series—Indication To use the sharing features on this page, please enable JavaScript. Go to slide 1 out of 4 Go to slide 2 ...

  15. Diagnostics for induction accelerators

    SciTech Connect

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960`s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore`s Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail.

  16. Diagnosing Diagnostic Language Assessment

    ERIC Educational Resources Information Center

    Lee, Yong-Won

    2015-01-01

    Diagnostic language assessment (DLA) is gaining a lot of attention from language teachers, testers, and applied linguists. With a recent surge of interest in DLA, there seems to be an urgent need to assess where the field of DLA stands at the moment and develop a general sense of where it should be moving in the future. The current article, as the…

  17. Beam Diagnostics for FACET

    SciTech Connect

    Li, S.Z.; Hogan, M.J.; /SLAC

    2011-08-19

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

  18. General considerations and updates in pediatric gastrointestinal diagnostic endoscopy

    PubMed Central

    2010-01-01

    Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review. PMID:21189965

  19. 7 CFR 1210.325 - Procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 10 2012-01-01 2012-01-01 false Procedure. 1210.325 Section 1210.325 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... accurate, full, and substantially identical explanation of each proposition. Telephone votes shall...

  20. 7 CFR 1210.325 - Procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 10 2011-01-01 2011-01-01 false Procedure. 1210.325 Section 1210.325 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... accurate, full, and substantially identical explanation of each proposition. Telephone votes shall...

  1. 7 CFR 1210.325 - Procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 10 2014-01-01 2014-01-01 false Procedure. 1210.325 Section 1210.325 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... accurate, full, and substantially identical explanation of each proposition. Telephone votes shall...

  2. Environmental Education: River Policy and Procedures.

    ERIC Educational Resources Information Center

    Snyder, Glenn; And Others

    Accurate as of October 1975, the guidebook establishes detailed procedures and policies to be used by all persons engaged in white water rafting trips involving students from Jefferson County (Colorado) Public Schools, and provides a general guide and set of instructions for anyone planning and carrying out such a trip. The guidelines are drawn…

  3. Molecular malaria diagnostics: A systematic review and meta-analysis.

    PubMed

    Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F

    2016-01-01

    Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.

  4. Turbine Engine Diagnostic Development. Phase I Report

    DTIC Science & Technology

    1972-11-01

    isolating the fault to a line-replaceable unit. A successful system will be able to replace conventional maintenance procedures with a nalntenance-as...Computer programming will be developed for a high resolution cathode ray tube (CRT). Parameter trending will be implemented as well as fault matrices...manipulation throughout its operating envelope. 2. That the project be continued to establish more accurate diagnosis and reduce false alarms. This will

  5. Saliva diagnostics - Current views and directions.

    PubMed

    Kaczor-Urbanowicz, Karolina Elżbieta; Martin Carreras-Presas, Carmen; Aro, Katri; Tu, Michael; Garcia-Godoy, Franklin; Wong, David Tw

    2017-03-01

    In this review, we provide an update on the current and future applications of saliva for diagnostic purposes. There are many advantages of using saliva as a biofluid. Its collection is fast, easy, inexpensive, and non-invasive. In addition, saliva, as a "mirror of the body," can reflect the physiological and pathological state of the body. Therefore, it serves as a diagnostic and monitoring tool in many fields of science such as medicine, dentistry, and pharmacotherapy. Introduced in 2008, the term "Salivaomics" aimed to highlight the rapid development of knowledge about various "omics" constituents of saliva, including: proteome, transcriptome, micro-RNA, metabolome, and microbiome. In the last few years, researchers have developed new technologies and validated a wide range of salivary biomarkers that will soon make the use of saliva a clinical reality. However, a great need still exists for convenient and accurate point-of-care devices that can serve as a non-invasive diagnostic tool. In addition, there is an urgent need to decipher the scientific rationale and mechanisms that convey systemic diseases to saliva. Another promising technology called liquid biopsy enables detection of circulating tumor cells (CTCs) and fragments of tumor DNA in saliva, thus enabling non-invasive early detection of various cancers. The newly developed technology-electric field-induced release and measurement (EFIRM) provides near perfect detection of actionable mutations in lung cancer patients. These recent advances widened the salivary diagnostic approach from the oral cavity to the whole physiological system, and thus point towards a promising future of salivary diagnostics for personalized individual medicine applications including clinical decisions and post-treatment outcome predictions. Impact statement The purpose of this mini-review is to make an update about the present and future applications of saliva as a diagnostic biofluid in many fields of science such as dentistry

  6. A time-accurate implicit method for chemical non-equilibrium flows at all speeds

    NASA Technical Reports Server (NTRS)

    Shuen, Jian-Shun

    1992-01-01

    A new time accurate coupled solution procedure for solving the chemical non-equilibrium Navier-Stokes equations over a wide range of Mach numbers is described. The scheme is shown to be very efficient and robust for flows with velocities ranging from M less than or equal to 10(exp -10) to supersonic speeds.

  7. Diagnostics and data fusion of robotic sensors

    SciTech Connect

    Dhar, M.; Bardsley, S; Cowper, L.; Hamm, R.; Jammu, V.; Wagner, J.

    1996-12-31

    Robotic systems for remediation of hazardous waste sites must be highly reliable to avoid equipment failures and subsequent possible exposure of personnel to hazardous environments. Safe, efficient cleanup operations also require accurate, complete knowledge of the task space. This paper presents progress made on a 18 month program to meet these needs. To enhance robot reliability, a conceptual design of a monitoring and diagnostic system is being developed to predict the onset of mechanical failure modes, provide maximum lead time to make operational changes or repairs, and minimize the occurrence of on-site breakdowns. To ensure safe operation, a comprehensive software package is being developed that will fuse data from multiple surface mapping sensors and poses so as to reduce the error effects in individual data points and provide accurate 3-D maps of a work space.

  8. [Inflammatory bowel diseases--imaging diagnostics].

    PubMed

    Gil, Jerzy; Wojtuń, Stanisław; Stec-Michalska, Krystyna; Chojnacki, Cezary

    2004-01-01

    The basic diagnostic procedure in ulcerative colitis is an endoscopy of gastrointestinal tract. It allows the macroscopic evaluation as well as the specimen taking for histological assessment what is the basis for ultimate diagnosis. In case of Crohn's disease the radiological diagnostics is of equal importance as endoscope evaluation. The imaging of inflammatory changes in Crohn's disease still poses some difficulties, especially, that located in the small intestine. Lately, the range of accessible examinations has been wider. We have in disposal the ultrasonography, the computed tomography, the magnetic resonance imaging and the capsular endoscopy. All of them are of great use in the diagnosis of Crohn's disease. In case of microscopic colitis all the imaging diagnostics has no use. The only one mean to establish the diagnosis is a histological assessment. What is more, in the period of remission the colon tissue could be normal. In this paper we discussed the traditional and contemporary intestine imaging methods in inflammatory bowel diseases. The conclusion is that the further progress in science offers a better imaging and, what is even more important, the more efficient diagnostics and treatment of these diseases.

  9. 40 CFR 75.20 - Initial certification and recertification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sensor and a data acquisition and handling system (DAHS) software component programmed with a moisture... accurately determined by applicable test methods and procedures; and (B) A stack or duct free of...

  10. Diagnostic of shock wave processes

    NASA Astrophysics Data System (ADS)

    Urtiew, P. A.

    1992-05-01

    Experimental measurements of high rate processes taking place in a shock wave dynamic environment require that the diagnostic systems have fast response and high resolution. This is not a trivial requirement considering the fact that under shock loading one can expect not only sudden changes of state across the shock discontinuity but also subsequent changes in pressure, temperature and volume due to chemical reaction, phase change and other transformations which may also take place behind the shock wave. Among the various parameters which provide direct ties to theoretical studies of the equation of state and at the same time yield to relatively accurate experimental measurements are shock velocity, particle velocity and pressure. Described here are the optical techniques VISAR and Fabry Perot interferometer for observing particle and free surface velocities in transparent media as well as in situ foil gauges for measuring pressure and particle velocity within the sample. Although these techniques are not new they have been continuously improved and upgraded at our facility to yield greater accuracy, reliability and state of the art performance. The emphasis in this paper is on the operational features of the measuring techniques, but examples of experimental results are also included.

  11. Diagnostic approach to Cushing disease.

    PubMed

    Gross, Bradley A; Mindea, Stefan A; Pick, Anthony J; Chandler, James P; Batjer, H Hunt

    2007-01-01

    In Cushing disease, a pituitary corticotroph neoplasm causes secondary adrenal hypercortisolism. This condition has known morbidity and mortality, underscoring the need for an efficient and accurate diagnostic approach. An 11 p.m. salivary cortisol level is a modern, simple initial screening tool for the diagnosis of Cushing syndrome. Confirmation with a 24-hour urinary free cortisol test and/or a low-dose dexamethasone suppression test may subsequently be performed. Patients with repeatedly equivocal results should be reevaluated after several months or undergo a corticotropin-releasing hormone (CRH) stimulation test following low-dose dexamethasone suppression to help rule out pseudo-Cushing states. The presence of low morning serum adrenocorticotropic hormone (ACTH) levels then distinguishes primary adrenal hypercortisolism from Cushing disease and the ectopic ACTH syndrome. Patients with moderate ACTH levels can undergo CRH stimulation testing to clarify the underlying disease because those with an ACTH-independent disorder have blunted subsequent ACTH levels. Once ACTH-dependent hypercortisolemia is detected, magnetic resonance (MR) imaging of the pituitary gland can be performed to detect a pituitary neoplasm. Normal or equivocal MR imaging results revealing small pituitary lesions should be followed up with inferior petrosal sinus sampling, a highly specific measure for the diagnosis of Cushing disease in experienced hands. If necessary, body imaging may be used in turn to detect sources of ectopic ACTH.

  12. The cost-effectiveness of diagnostic cardiac imaging for stable coronary artery disease.

    PubMed

    Turchetti, Giuseppe; Kroes, M A; Lorenzoni, Valentina; Trieste, Leopoldo; Chapman, Ann-Marie; Sweet, Alison C; Wilson, Geoff I; Neglia, Danilo

    2015-01-01

    Early and accurate diagnosis of stable coronary artery disease (CAD) is crucial to reduce morbidity, mortality and healthcare costs. This critical appraisal of health-economic literature concerning non-invasive diagnostic cardiac imaging aims to summarize current approaches to economic evaluation of diagnostic cardiac imaging and associated procedural risks, inform cardiologists how to use economic analyses for decision-making, highlight areas where new information could strengthen the economic evaluation and shed light on cost-effective approaches to diagnose stable CAD. Economic analysis can support cardiologists' decision-making. Current economic evidence in the field does not provide sufficient information to guide the choice among different imaging modalities or strategies for each patient. Available economic analyses suggest that computed tomography coronary angiography (CTCA) is a cost-effective approach to rule out CAD prior to invasive coronary angiography in patients with low to intermediate pre-test probability of disease and that stress imaging modalities may be cost-effective at variable pre-test probabilities.

  13. State of the art diagnostic of mold diseases: a practical guide for clinicians.

    PubMed

    Beirão, F; Araujo, R

    2013-01-01

    The epidemiology of fungal diseases changed, and molds have been increasingly associated with high mortality in severe immunocompromised patients. Invasive mold diseases may originate from the airborne conidia through inhalation or inoculation in skin fissures associated with indwelling catheters, wounds, burns, or onychomycosis. The diagnosis and treatment of fungal diseases is problematic and raises considerable challenges. Diagnosis of invasive mold diseases includes several methodologies, of which the most commonly used are the cultural methods, antigen testing, nucleic acid detection, and radiological imaging. Galactomannan and (1 → 3)-β-D-glucan detection significantly improved mold diagnosis in the last decade. Several molecular strategies have been proposed over the years but no consensus was achieved for standardized protocols or cut-off values. Recently, the first commercially available molecular assay for detection of Aspergillus was tested and the results were highly reproducible. In addition, blood cultures may also be helpful for invasive aspergillosis by following a novel procedure for the recovery of Aspergillus spp. from blood cultures. The association of distinct diagnostic methods, particularly molecular tests, galactomannan, and/or (1 → 3)-β-D-glucan detection, may provide earlier and more sensitive diagnosis of mold diseases and be indicative for early antifungal treatment. Accurate routine use of diagnostic tests can be cost-effective for laboratories and be of great value to patients.

  14. Multifocal Nodular Fatty Infiltration of the Liver: A Case Report of a Challenging Diagnostic Problem

    PubMed Central

    Tebala, Giovanni Domenico; Jwad, Anees; Khan, Abdul Quyyum; Long, Ervine; Sissons, Guy

    2016-01-01

    Patient: Female, 59 Final Diagnosis: Multifocal nodular fatty infiltration of the liver Symptoms: None Medication: — Clinical Procedure: Laparoscopy Specialty: Surgery Objective: Rare disease Background: Fatty infiltration of the liver usually has a diffuse pattern, but in very rare cases it presents as multiple focal lesions of the liver, mimicking metastases. A correct diagnosis is crucial to address prognosis and eventual treatment. Case Report: We present the case of a completely fit and asymptomatic patient referred for multiple bilateral liver metastases of unknown origin. She had no previous history of malignancy. She was extensively investigated with all locally available methods, including ultrasound scan, computed tomography, magnetic resonance imaging, upper and lower gastrointestinal endoscopy, and diagnostic laparoscopy. Imaging-guided biopsy and laparoscopic biopsy confirmed the diagnosis of multifocal fatty infiltration of the liver. Conclusions: The diagnosis of this condition can be challenging and an accurate initial clinical history must be part of a thorough clinical examination. Multimodal imaging is mandatory, but diagnostic laparoscopy with direct macrobiopsy may be necessary to clear all doubts. PMID:27017525

  15. Radiation injuries after fluoroscopic procedures.

    PubMed

    Mettler, Fred A; Koenig, Titus R; Wagner, Louis K; Kelsey, Charles A

    2002-10-01

    Fluoroscopically guided diagnostic and interventional procedures have become much more commonplace over the last decade. Current fluoroscopes are easily capable of producing dose rates in the range of 0.2 Gy (20 rads) per minute. The dose rate often changes dramatically with patient positioning and size. Most machines currently in use have no method to display approximate patient dose other than the rough surrogate of total fluoroscopy time. This does not include patient dose incurred during fluorography (serial imaging or cine runs), which can be considerably greater than dose during fluoroscopy. There have been over 100 cases of documented radiation skin and underlying tissue injury, a large portion of which resulted in dermal necrosis. The true number of injuries is undoubtedly much higher. The highest dose procedures are complex interventions such as those involving percutaneous angioplasties, stent placements, embolizations, and TIPS. In some cases skin doses have been in excess of 60 Gy (6000 rads). In many instances the procedures have been performed by physicians with little training in radiation effects, little appreciation of the radiation injuries that are possible or the strategies that could have been used to reduce both patient and staff doses. Almost all of the severe injuries that have occurred were avoidable.

  16. Accurate upwind methods for the Euler equations

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1993-01-01

    A new class of piecewise linear methods for the numerical solution of the one-dimensional Euler equations of gas dynamics is presented. These methods are uniformly second-order accurate, and can be considered as extensions of Godunov's scheme. With an appropriate definition of monotonicity preservation for the case of linear convection, it can be shown that they preserve monotonicity. Similar to Van Leer's MUSCL scheme, they consist of two key steps: a reconstruction step followed by an upwind step. For the reconstruction step, a monotonicity constraint that preserves uniform second-order accuracy is introduced. Computational efficiency is enhanced by devising a criterion that detects the 'smooth' part of the data where the constraint is redundant. The concept and coding of the constraint are simplified by the use of the median function. A slope steepening technique, which has no effect at smooth regions and can resolve a contact discontinuity in four cells, is described. As for the upwind step, existing and new methods are applied in a manner slightly different from those in the literature. These methods are derived by approximating the Euler equations via linearization and diagonalization. At a 'smooth' interface, Harten, Lax, and Van Leer's one intermediate state model is employed. A modification for this model that can resolve contact discontinuities is presented. Near a discontinuity, either this modified model or a more accurate one, namely, Roe's flux-difference splitting. is used. The current presentation of Roe's method, via the conceptually simple flux-vector splitting, not only establishes a connection between the two splittings, but also leads to an admissibility correction with no conditional statement, and an efficient approximation to Osher's approximate Riemann solver. These reconstruction and upwind steps result in schemes that are uniformly second-order accurate and economical at smooth regions, and yield high resolution at discontinuities.

  17. Accurate measurement of unsteady state fluid temperature

    NASA Astrophysics Data System (ADS)

    Jaremkiewicz, Magdalena

    2017-03-01

    In this paper, two accurate methods for determining the transient fluid temperature were presented. Measurements were conducted for boiling water since its temperature is known. At the beginning the thermometers are at the ambient temperature and next they are immediately immersed into saturated water. The measurements were carried out with two thermometers of different construction but with the same housing outer diameter equal to 15 mm. One of them is a K-type industrial thermometer widely available commercially. The temperature indicated by the thermometer was corrected considering the thermometers as the first or second order inertia devices. The new design of a thermometer was proposed and also used to measure the temperature of boiling water. Its characteristic feature is a cylinder-shaped housing with the sheath thermocouple located in its center. The temperature of the fluid was determined based on measurements taken in the axis of the solid cylindrical element (housing) using the inverse space marching method. Measurements of the transient temperature of the air flowing through the wind tunnel using the same thermometers were also carried out. The proposed measurement technique provides more accurate results compared with measurements using industrial thermometers in conjunction with simple temperature correction using the inertial thermometer model of the first or second order. By comparing the results, it was demonstrated that the new thermometer allows obtaining the fluid temperature much faster and with higher accuracy in comparison to the industrial thermometer. Accurate measurements of the fast changing fluid temperature are possible due to the low inertia thermometer and fast space marching method applied for solving the inverse heat conduction problem.

  18. The first accurate description of an aurora

    NASA Astrophysics Data System (ADS)

    Schröder, Wilfried

    2006-12-01

    As technology has advanced, the scientific study of auroral phenomena has increased by leaps and bounds. A look back at the earliest descriptions of aurorae offers an interesting look into how medieval scholars viewed the subjects that we study.Although there are earlier fragmentary references in the literature, the first accurate description of the aurora borealis appears to be that published by the German Catholic scholar Konrad von Megenberg (1309-1374) in his book Das Buch der Natur (The Book of Nature). The book was written between 1349 and 1350.

  19. Determining accurate distances to nearby galaxies

    NASA Astrophysics Data System (ADS)

    Bonanos, Alceste Zoe

    2005-11-01

    Determining accurate distances to nearby or distant galaxies is a very simple conceptually, yet complicated in practice, task. Presently, distances to nearby galaxies are only known to an accuracy of 10-15%. The current anchor galaxy of the extragalactic distance scale is the Large Magellanic Cloud, which has large (10-15%) systematic uncertainties associated with it, because of its morphology, its non-uniform reddening and the unknown metallicity dependence of the Cepheid period-luminosity relation. This work aims to determine accurate distances to some nearby galaxies, and subsequently help reduce the error in the extragalactic distance scale and the Hubble constant H 0 . In particular, this work presents the first distance determination of the DIRECT Project to M33 with detached eclipsing binaries. DIRECT aims to obtain a new anchor galaxy for the extragalactic distance scale by measuring direct, accurate (to 5%) distances to two Local Group galaxies, M31 and M33, with detached eclipsing binaries. It involves a massive variability survey of these galaxies and subsequent photometric and spectroscopic follow-up of the detached binaries discovered. In this work, I also present a catalog of variable stars discovered in one of the DIRECT fields, M31Y, which includes 41 eclipsing binaries. Additionally, we derive the distance to the Draco Dwarf Spheroidal galaxy, with ~100 RR Lyrae found in our first CCD variability study of this galaxy. A "hybrid" method of discovering Cepheids with ground-based telescopes is described next. It involves applying the image subtraction technique on the images obtained from ground-based telescopes and then following them up with the Hubble Space Telescope to derive Cepheid period-luminosity distances. By re-analyzing ESO Very Large Telescope data on M83 (NGC 5236), we demonstrate that this method is much more powerful for detecting variability, especially in crowded fields. I finally present photometry for the Wolf-Rayet binary WR 20a

  20. New law requires 'medically accurate' lesson plans.

    PubMed

    1999-09-17

    The California Legislature has passed a bill requiring all textbooks and materials used to teach about AIDS be medically accurate and objective. Statements made within the curriculum must be supported by research conducted in compliance with scientific methods, and published in peer-reviewed journals. Some of the current lesson plans were found to contain scientifically unsupported and biased information. In addition, the bill requires material to be "free of racial, ethnic, or gender biases." The legislation is supported by a wide range of interests, but opposed by the California Right to Life Education Fund, because they believe it discredits abstinence-only material.

  1. Merits and Pitfalls of Currently Used Diagnostic Tools in Mycetoma

    PubMed Central

    van de Sande, Wendy W. J.; Fahal, Ahmed H.; Goodfellow, Michael; Mahgoub, El Sheikh; Welsh, Oliverio; Zijlstra, Ed E.

    2014-01-01

    Treatment of mycetoma depends on the causative organism and since many organisms, both actinomycetes (actinomycetoma) and fungi (eumycetoma), are capable of producing mycetoma, an accurate diagnosis is crucial. Currently, multiple diagnostic tools are used to determine the extent of infections and to identify the causative agents of mycetoma. These include various imaging, cytological, histopathological, serological, and culture techniques; phenotypic characterisation; and molecular diagnostics. In this review, we summarize these techniques and identify their merits and pitfalls in the identification of the causative agents of mycetoma and the extent of the disease. We also emphasize the fact that there is no ideal diagnostic tool available to identify the causative agents and that future research should focus on the development of new and reliable diagnostic tools. PMID:24992636

  2. Diagnostic scope and certainty: an analysis of FNP practice.

    PubMed

    Draye, M A; Pesznecker, B L

    1979-01-01

    The health problems of 2,136 patients randomly selected from 8,905 patients seen by 356 family nurse practitioners around the U.S.A. were analyzed. Primary diagnoses were reported on all patients using an adapted H-ICDA/ICHPPC classification. This system allowed for 18 diagnostic categories and 115 diagnoses relevant to primary care. The ten most frequent diagnostic categories were reported and analyzed as to certainty and status (old or new diagnosis). Analysis of diagnostic certainty revealed areas where FNPs felt most accurate. Reporting both diagnoses and diagnostic categories allowed greater understanding of the health problems presented to family nurse practitioners in primary care. This comprehensive data bank of patient care problems adds another dimension to the study of primary care and is a useful tool in further family nurse practitioner research and in curriculum development.

  3. Optical diagnostics in the oral cavity: an overview

    PubMed Central

    Wilder-Smith, P; Holtzman, J; Epstein, J; Le, A

    2014-01-01

    As the emphasis shifts from damage mitigation to disease prevention or reversal of early disease in the oral cavity, the need for sensitive and accurate detection and diagnostic tools become more important. Many novel and emergent optical diagnostic modalities for the oral cavity are becoming available to clinicians with a variety of desirable attributes including: (i) non-invasiveness, (ii) absence of ionizing radiation, (iii) patient-friendliness, (iv) real-time information (v) repeatability, and (vi) high-resolution surface and subsurface images. In this article, the principles behind optical diagnostic approaches, their feasibility and applicability for imaging soft and hard tissues, and their potential usefulness as a tool in the diagnosis of oral mucosal lesions, dental pathologies, and other dental applications will be reviewed. The clinical applications of light-based imaging technologies in the oral cavity and of their derivative devices will be discussed to provide the reader with a comprehensive understanding of emergent diagnostic modalities. PMID:20561224

  4. Accurate Completion of Medical Report on Diagnosing Death.

    PubMed

    Savić, Slobodan; Alempijević, Djordje; Andjelić, Sladjana

    2015-01-01

    Diagnosing death and issuing a Death Diagnosing Form (DDF) represents an activity that carries a great deal of public responsibility for medical professionals of the Emergency Medical Services (EMS) and is perpetually exposed to the control of the general public. Diagnosing death is necessary so as to confirm true, to exclude apparent death and consequentially to avoid burying a person alive, i.e. apparently dead. These expert-methodological guidelines based on the most up-to-date and medically based evidence have the goal of helping the physicians of the EMS in accurately filling out a medical report on diagnosing death. If the outcome of applied cardiopulmonary resuscitation measures is negative or when the person is found dead, the physician is under obligation to diagnose death and correctly fill out the DDF. It is also recommended to perform electrocardiography (EKG) and record asystole in at least two leads. In the process of diagnostics and treatment, it is a moral obligation of each Belgrade EMS physician to apply all available achievements and knowledge of modern medicine acquired from extensive international studies, which have been indeed the major theoretical basis for the creation of these expert-methodological guidelines. Those acting differently do so in accordance with their conscience and risk professional, and even criminal sanctions.

  5. ICF diagnostics. Revision 1

    SciTech Connect

    Coleman, L.W.

    1982-12-17

    In the past several years there have been significant advances and accomplishments in the field of Inertial Confinement Fusion (ICF) research which are directly attributable to an active experimental program supported by the development and applications of sophisticated and specialized diagnostics instruments and techniques. The continued development of high temporal-and spatial-resolution diagnostics, although with a somewhat different technical emphasis than previously, is essential for maintaining progress in ICF. With the generation of inertial fusion drivers now becoming available progress toward higher density compression of fusion fuel will be attained at the expense of temperature, and consequently emissions from the targets will be limited. At the same time since the targets are being driven to higher density they are more opaque to the low-to-moderate energy x-rays (up to a few keV) and particles (alpha particles, protons, and knock-on charged particles) that have been utilized for diagnosing target performance.

  6. Viral Hemorrhagic Fever Diagnostics

    PubMed Central

    Racsa, Lori D.; Kraft, Colleen S.; Olinger, Gene G.; Hensley, Lisa E.

    2016-01-01

    There are 4 families of viruses that cause viral hemorrhagic fever (VHF), including Filoviridae. Ebola virus is one virus within the family Filoviridae and the cause of the current outbreak of VHF in West Africa. VHF-endemic areas are found throughout the world, yet traditional diagnosis of VHF has been performed in large reference laboratories centered in Europe and the United States. The large amount of capital needed, as well as highly trained and skilled personnel, has limited the availability of diagnostics in endemic areas except in conjunction with governmental and nongovernmental entities. However, rapid diagnosis of VHF is essential to efforts that will limit outbreaks. In addition, increased global travel suggests VHF diagnoses may be made outside of the endemic areas. Thus, understanding how to diagnose VHF is imperative for laboratories worldwide. This article reviews traditional and current diagnostic modalities for VHF. PMID:26354968

  7. Cardiovascular modeling and diagnostics

    SciTech Connect

    Kangas, L.J.; Keller, P.E.; Hashem, S.; Kouzes, R.T.

    1995-12-31

    In this paper, a novel approach to modeling and diagnosing the cardiovascular system is introduced. A model exhibits a subset of the dynamics of the cardiovascular behavior of an individual by using a recurrent artificial neural network. Potentially, a model will be incorporated into a cardiovascular diagnostic system. This approach is unique in that each cardiovascular model is developed from physiological measurements of an individual. Any differences between the modeled variables and the variables of an individual at a given time are used for diagnosis. This approach also exploits sensor fusion to optimize the utilization of biomedical sensors. The advantage of sensor fusion has been demonstrated in applications including control and diagnostics of mechanical and chemical processes.

  8. Advances in diagnostic radiology.

    PubMed

    Runge, Val M

    2010-12-01

    Recent advances in diagnostic radiology are discussed on the basis of current publications in Investigative Radiology. Publications in the journal during 2009 and 2010 are reviewed, evaluating developments by modality and anatomic region. Technological advances continue to play a major role in the evolution and clinical practice of diagnostic radiology, and as such constitute a major publication focus. In the past 2 years, this includes advances in both magnetic resonance and computed tomography (in particular, the advent of dual energy computed tomography). An additional major focus of publications concerns contrast media, and in particular continuing research involving nephrogenic systemic fibrosis, its etiology, and differentiation of the gadolinium chelates on the basis of in vivo stability.

  9. Collective effective dose from diagnostic radiology in Ukraine.

    PubMed

    Stadnyk, L; Shalopa, O; Nosyk, O

    2015-07-01

    The frequencies and effective doses for the most common X-ray diagnostic examinations in Ukraine were assessed in the frame of the European Commission (EC) Study on European Population Doses from Medical Exposure (Dose Datamed 2). The average effective doses for all radiographic procedures were estimated using the ODS-60 software (Finland). The estimation of the effective doses for the chest film fluorography was carried out from the results of own representative measurements with thermoluminescent (TL) dosimetry and a standard Alderson-Rando phantom. The effective doses for fluoroscopy procedures were assessed using the Russian guidelines for estimation of effective doses. For all other X-ray examinations and procedures [computed tomography (CT), angiography and interventional procedures], typical effective dose values were taken from the EC Guidance RP154. The most frequently performed in Ukraine is chest film fluorography, with 389 examinations per 1000 population annually, reflecting in the greatest contribution to the total collective effective dose (CED) of 428 mSv per 1000 population (44 %). The total frequency and CED from all X-ray diagnostic examinations and procedures were estimated to be 1218 examinations and 1060 mSv per 1000 populations, respectively. The expected additional cancer risk from X-ray diagnostic examinations and interventional procedures is 2680 cases per year, with 1200 of them due to the contribution of chest fluorography. The main important action in radiation protection of patients in diagnostic radiology is the organisation of the monitoring of patient doses for different types of X-ray diagnostic examinations and replacement of chest film fluorography with digital X-ray systems.

  10. Accurate taxonomic assignment of short pyrosequencing reads.

    PubMed

    Clemente, José C; Jansson, Jesper; Valiente, Gabriel

    2010-01-01

    Ambiguities in the taxonomy dependent assignment of pyrosequencing reads are usually resolved by mapping each read to the lowest common ancestor in a reference taxonomy of all those sequences that match the read. This conservative approach has the drawback of mapping a read to a possibly large clade that may also contain many sequences not matching the read. A more accurate taxonomic assignment of short reads can be made by mapping each read to the node in the reference taxonomy that provides the best precision and recall. We show that given a suffix array for the sequences in the reference taxonomy, a short read can be mapped to the node of the reference taxonomy with the best combined value of precision and recall in time linear in the size of the taxonomy subtree rooted at the lowest common ancestor of the matching sequences. An accurate taxonomic assignment of short reads can thus be made with about the same efficiency as when mapping each read to the lowest common ancestor of all matching sequences in a reference taxonomy. We demonstrate the effectiveness of our approach on several metagenomic datasets of marine and gut microbiota.

  11. Accurate shear measurement with faint sources

    SciTech Connect

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao E-mail: walt@shao.ac.cn

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys.

  12. Accurate pose estimation for forensic identification

    NASA Astrophysics Data System (ADS)

    Merckx, Gert; Hermans, Jeroen; Vandermeulen, Dirk

    2010-04-01

    In forensic authentication, one aims to identify the perpetrator among a series of suspects or distractors. A fundamental problem in any recognition system that aims for identification of subjects in a natural scene is the lack of constrains on viewing and imaging conditions. In forensic applications, identification proves even more challenging, since most surveillance footage is of abysmal quality. In this context, robust methods for pose estimation are paramount. In this paper we will therefore present a new pose estimation strategy for very low quality footage. Our approach uses 3D-2D registration of a textured 3D face model with the surveillance image to obtain accurate far field pose alignment. Starting from an inaccurate initial estimate, the technique uses novel similarity measures based on the monogenic signal to guide a pose optimization process. We will illustrate the descriptive strength of the introduced similarity measures by using them directly as a recognition metric. Through validation, using both real and synthetic surveillance footage, our pose estimation method is shown to be accurate, and robust to lighting changes and image degradation.

  13. Sparse and accurate high resolution SAR imaging

    NASA Astrophysics Data System (ADS)

    Vu, Duc; Zhao, Kexin; Rowe, William; Li, Jian

    2012-05-01

    We investigate the usage of an adaptive method, the Iterative Adaptive Approach (IAA), in combination with a maximum a posteriori (MAP) estimate to reconstruct high resolution SAR images that are both sparse and accurate. IAA is a nonparametric weighted least squares algorithm that is robust and user parameter-free. IAA has been shown to reconstruct SAR images with excellent side lobes suppression and high resolution enhancement. We first reconstruct the SAR images using IAA, and then we enforce sparsity by using MAP with a sparsity inducing prior. By coupling these two methods, we can produce a sparse and accurate high resolution image that are conducive for feature extractions and target classification applications. In addition, we show how IAA can be made computationally efficient without sacrificing accuracies, a desirable property for SAR applications where the size of the problems is quite large. We demonstrate the success of our approach using the Air Force Research Lab's "Gotcha Volumetric SAR Data Set Version 1.0" challenge dataset. Via the widely used FFT, individual vehicles contained in the scene are barely recognizable due to the poor resolution and high side lobe nature of FFT. However with our approach clear edges, boundaries, and textures of the vehicles are obtained.

  14. Accurate basis set truncation for wavefunction embedding

    NASA Astrophysics Data System (ADS)

    Barnes, Taylor A.; Goodpaster, Jason D.; Manby, Frederick R.; Miller, Thomas F.

    2013-07-01

    Density functional theory (DFT) provides a formally exact framework for performing embedded subsystem electronic structure calculations, including DFT-in-DFT and wavefunction theory-in-DFT descriptions. In the interest of efficiency, it is desirable to truncate the atomic orbital basis set in which the subsystem calculation is performed, thus avoiding high-order scaling with respect to the size of the MO virtual space. In this study, we extend a recently introduced projection-based embedding method [F. R. Manby, M. Stella, J. D. Goodpaster, and T. F. Miller III, J. Chem. Theory Comput. 8, 2564 (2012)], 10.1021/ct300544e to allow for the systematic and accurate truncation of the embedded subsystem basis set. The approach is applied to both covalently and non-covalently bound test cases, including water clusters and polypeptide chains, and it is demonstrated that errors associated with basis set truncation are controllable to well within chemical accuracy. Furthermore, we show that this approach allows for switching between accurate projection-based embedding and DFT embedding with approximate kinetic energy (KE) functionals; in this sense, the approach provides a means of systematically improving upon the use of approximate KE functionals in DFT embedding.

  15. Microsphere based saliva diagnostics

    NASA Astrophysics Data System (ADS)

    Rissin, David M.; DiCesare, Christopher; Hayman, Ryan B.; Blicharz, Timothy M.; Walt, David R.

    2005-11-01

    Saliva presents a minimally invasive alternative medium to blood for performing diagnostics1. Microsphere sensors for ions, small organic molecules, and proteins are currently being developed and optical microarrays containing thousands of these sensors will be used for simultaneous multi-analyte analysis. The fiber bundle platform in use is 1mm in diameter and contains approximately 50,000 individually addressable 3.1μm fibers, each with an etched well capable of housing a single 3.1μm microsphere sensor. Micron-sized bead-based chemistries are produced in house, followed by deposition onto a fiber-optic bundle platform, allowing for multiplexed analysis. The ultimate goal is to develop a universal diagnostic system using saliva as the diagnostic medium. This platform will permit multiplexed analysis of a sample by integrating microfluidics with the optical arrays loaded with sensors capable of detecting relevant biomarkers associated with a wide range of disease states. Disease states that are currently under investigation include end stage renal disease (ESRD) and Sjoegrens Syndrome (SS).

  16. Microgravity Combustion Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Santoro, Gilbert J. (Editor); Greenberg, Paul S. (Editor); Piltch, Nancy D. (Editor)

    1988-01-01

    Through the Microgravity Science and Applications Division (MSAD) of the Office of Space Science and Applications (OSSA) at NASA Headquarters, a program entitled, Advanced Technology Development (ATD) was promulgated with the objective of providing advanced technologies that will enable the development of future microgravity science and applications experimental flight hardware. Among the ATD projects one, Microgravity Combustion Diagnostics (MCD), has the objective of developing advanced diagnostic techniques and technologies to provide nonperturbing measurements of combustion characteristics and parameters that will enhance the scientific integrity and quality of microgravity combustion experiments. As part of the approach to this project, a workshop was held on July 28 and 29, 1987, at the NASA Lewis Research Center. A small group of laser combustion diagnosticians met with a group of microgravity combustion experimenters to discuss the science requirements, the state-of-the-art of laser diagnostic technology, and plan the direction for near-, intermediate-, and long-term programs. This publication describes the proceedings of that workshop.

  17. [Histopathological meniscus diagnostic].

    PubMed

    Fisseler-Eckhoff, A; Müller, K-M

    2009-06-01

    Menisci fulfill many functions within the complex biomechanics of the knee joint. In the case of meniscus lesions, sparing arthroscopic resections and operative refixation are the treatments of choice. With regard to diagnostics, this means that in general terms, the histopathologic diagnostics are carried out on detached meniscus fragments of between 5 mm and 2 cm in size. An experienced pathologist's knowledge of physiologically possible cellular and fibrous histological meniscus damage, as opposed to nonphysiological change regarded as normal with respect to age, is essential during a diagnostic meniscus evaluation. The clinician expects clear statements from the pathologist regarding the severity of previous or secondary degenerative meniscus damage, the age and type of traumatic tears, and appraisal of the relationship between trauma and meniscus damage from an insurance point of view. Close cooperation between the clinician and the pathologist allows for fast and unambiguous correlation of anamnesis, the clinical picture, and morphological reporting so that cases involving insurance problems - which are numerous, often long-term, and often unsatisfactory - can be clarified quickly.

  18. Alpha Particle Diagnostic

    SciTech Connect

    Fisher, Ray, K.

    2009-05-13

    The study of burning plasmas is the next frontier in fusion energy research, and will be a major objective of the U.S. fusion program through U.S. collaboration with our international partners on the ITER Project. For DT magnetic fusion to be useful for energy production, it is essential that the energetic alpha particles produced by the fusion reactions be confined long enough to deposit a significant fraction of their initial ~3.5 MeV energy in the plasma before they are lost. Development of diagnostics to study the behavior of energetic confined alpha particles is a very important if not essential part of burning plasma research. Despite the clear need for these measurements, development of diagnostics to study confined the fast confined alphas to date has proven extremely difficult, and the available techniques remain for the most part unproven and with significant uncertainties. Research under this grant had the goal of developing diagnostics of fast confined alphas, primarily based on measurements of the neutron and ion tails resulting from alpha particle knock-on collisions with the plasma deuterium and tritium fuel ions. One of the strengths of this approach is the ability to measure the alphas in the hot plasma core where the interesting ignition physics will occur.

  19. A New Diagnostic Test for Endometrial Cancer?

    PubMed Central

    Guralp, Onur; Sheridan, Susan M.; Harter, Josephine; Hinshaw, James Louis; Seo, Songwon; Hartenbach, Ellen M.; Lindheim, Steven; Stewar, Sarah; Kushner, David M.

    2014-01-01

    Objective During saline-infused sonohysterography (SIS), the distension fluid is typically discarded. If cytology analysis could identify those patients with endometrial cancer, many women would be spared from further procedures. Methods Thirty consecutive patients with clinical stage I or II endometrial adenocarcinoma were prospectively recruited preoperatively. Saline-infused sonohysterography was performed by instilling 5 mL of saline, withdrawing and sending for analysis. Saline was reinfused until complete SIS images were obtained and sent separately for cytology. Results Of the 30 women enrolled, SIS was technically successful in 29. Demographics included mean age (60.5 ± 6.99 years), body mass index (35.55 ± 8.18 kg/m2), endometrioid histology (76%), and grade (grade 1, 67%). Prestudy diagnostic method included biopsy (70%), dilatation and curettage (17%), and hysteroscopy (10%). Adequate cytology specimens were obtained in 66% of the 5mL flushes and 72% of the complete SIS collections. Of adequate specimens, the sensitivities to detect endometrial cancer for the 5-mL, complete, and combined fluid samples were 26% (95% confidence interval, 9%–51%), 36% (17%–59%), and 42% (22%–63%). Sensitivity based on the whole study sample (N = 30) was 33% (17%–53%). Statistical significance was not found in the association between a positive test and age, body mass index, grade, diagnostic method, or volume instilled or aspirated. Conclusions Most patients with early endometrial cancer can undergo SIS procedures with adequate cytology specimens obtained from distention media. However, the sensitivity is low, and refinements are necessary before utilizing as a diagnostic test. In cases with positive results, the patient may be able to avoid other costly and painful procedures. PMID:23881100

  20. Troubleshooting the diagnostic conundrums

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Because so many different clinical presentations can be associated with infection with BVDV, diagnosis based on history, clinical presentation, and postmortem of affected animals is presumptive at best. Accurate and definitive detection of infection with BVDV depends on laboratory diagnosis. While t...

  1. Photovoltaic array space power plus diagnostics experiment

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1990-01-01

    The objective is to summarize the five years of hardware development and fabrication represented by the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) Instrument. The original PASP Experiment requirements and background is presented along with the modifications which were requested to transform the PASP Experiment into the PASP Plus Instrument. The PASP Plus hardware and software is described. Test results for components and subsystems are given as well as final system tests. Also included are appendices which describe the major subsystems and present supporting documentation such as block diagrams, schematics, circuit board artwork, drawings, test procedures and test reports.

  2. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    PubMed

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  3. Computerized procedures system

    DOEpatents

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  4. Designing Flightdeck Procedures

    NASA Technical Reports Server (NTRS)

    Barshi, Immanuel; Mauro, Robert; Degani, Asaf; Loukopoulou, Loukia

    2016-01-01

    The primary goal of this document is to provide guidance on how to design, implement, and evaluate flight deck procedures. It provides a process for developing procedures that meet clear and specific requirements. This document provides a brief overview of: 1) the requirements for procedures, 2) a process for the design of procedures, and 3) a process for the design of checklists. The brief overview is followed by amplified procedures that follow the above steps and provide details for the proper design, implementation and evaluation of good flight deck procedures and checklists.

  5. Accurate determination of serum ASAT isoenzymes.

    PubMed

    Konttinen, A; Ojala, K

    1978-01-01

    An improved electrophoretic modification for measuring aspartate aminotransferase (ASAT) isoenzymes is presented. This method fulfils the clinical requirements for sensitivity and allows the detection of 1 U/l mitochondria ASAT activity at 25 degree C. The procedure is relatively simple, requiring about one hour for a series of 8 determinations. Mitochondrial ASAT activity was found in all patients suffering from acute myocardial infarction pathological activity was observed for several days longer than that of total serum ASAT enzyme. None of the 25 healthy people studied had mitochondrial ASAT in their serum.

  6. RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 2. APPENDICES

    EPA Science Inventory

    The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...

  7. Case-Deletion Diagnostics for Nonlinear Structural Equation Models

    ERIC Educational Resources Information Center

    Lee, Sik-Yum; Lu, Bin

    2003-01-01

    In this article, a case-deletion procedure is proposed to detect influential observations in a nonlinear structural equation model. The key idea is to develop the diagnostic measures based on the conditional expectation of the complete-data log-likelihood function in the EM algorithm. An one-step pseudo approximation is proposed to reduce the…

  8. Assessing Fit of Cognitive Diagnostic Models: A Case Study

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Almond, Russell G.

    2007-01-01

    A cognitive diagnostic model uses information from educational experts to describe the relationships between item performances and posited proficiencies. When the cognitive relationships can be described using a fully Bayesian model, Bayesian model checking procedures become available. Checking models tied to cognitive theory of the domains…

  9. Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua

    2012-01-01

    This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…

  10. The IHS diagnostic X-ray equipment radiation protection program

    SciTech Connect

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-05-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload.

  11. Diagnostics for fast ignition science (invited)

    SciTech Connect

    MacPhee, A. G.; Chen, C. D.; Chen, H.; Hey, D. S.; Kemp, A. J.; Key, M. H.; Le Pape, S.; Patel, P. K.; Phillips, T. W.; Town, R.; Mackinnon, A. J.; Akli, K. U.; Stephens, R. B.; Beg, F. N.; King, J. A.; Ma, T. Y.; Wei, M. S.; Clarke, R.; Freeman, R. R.; Link, A.

    2008-10-15

    The ignition concept for electron fast ignition inertial confinement fusion requires sufficient energy be transferred from an {approx}20 ps laser pulse to the compressed fuel via approximately MeV electrons. We have assembled a suite of diagnostics to characterize such transfer, simultaneously fielding absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256 eV; spherically bent crystal imagers at 4.5 and 8 keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung, electron and proton spectrometers (along the same line of sight), and a picosecond optical probe interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following the laser-plasma interactions at extremely high intensities in both planar and conical targets. Together with accurate on-shot laser focal spot and prepulse characterization, these measurements are yielding new insights into energy coupling and are providing critical data for validating numerical particle-in-cell (PIC) and hybrid PIC simulation codes in an area crucial for fast ignition and other applications. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultrahigh intensity laser-plasma interactions are discussed.

  12. Microfluidic diagnostics for low-resource settings

    NASA Astrophysics Data System (ADS)

    Hawkins, Kenneth R.; Weigl, Bernhard H.

    2010-02-01

    Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.

  13. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  14. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, Douglas D.

    1985-01-01

    The present invention is a thermometer used for measuring furnace temperaes in the range of about 1800.degree. to 2700.degree. C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  15. LSM: perceptually accurate line segment merging

    NASA Astrophysics Data System (ADS)

    Hamid, Naila; Khan, Nazar

    2016-11-01

    Existing line segment detectors tend to break up perceptually distinct line segments into multiple segments. We propose an algorithm for merging such broken segments to recover the original perceptually accurate line segments. The algorithm proceeds by grouping line segments on the basis of angular and spatial proximity. Then those line segment pairs within each group that satisfy unique, adaptive mergeability criteria are successively merged to form a single line segment. This process is repeated until no more line segments can be merged. We also propose a method for quantitative comparison of line segment detection algorithms. Results on the York Urban dataset show that our merged line segments are closer to human-marked ground-truth line segments compared to state-of-the-art line segment detection algorithms.

  16. Highly accurate articulated coordinate measuring machine

    DOEpatents

    Bieg, Lothar F.; Jokiel, Jr., Bernhard; Ensz, Mark T.; Watson, Robert D.

    2003-12-30

    Disclosed is a highly accurate articulated coordinate measuring machine, comprising a revolute joint, comprising a circular encoder wheel, having an axis of rotation; a plurality of marks disposed around at least a portion of the circumference of the encoder wheel; bearing means for supporting the encoder wheel, while permitting free rotation of the encoder wheel about the wheel's axis of rotation; and a sensor, rigidly attached to the bearing means, for detecting the motion of at least some of the marks as the encoder wheel rotates; a probe arm, having a proximal end rigidly attached to the encoder wheel, and having a distal end with a probe tip attached thereto; and coordinate processing means, operatively connected to the sensor, for converting the output of the sensor into a set of cylindrical coordinates representing the position of the probe tip relative to a reference cylindrical coordinate system.

  17. Practical aspects of spatially high accurate methods

    NASA Technical Reports Server (NTRS)

    Godfrey, Andrew G.; Mitchell, Curtis R.; Walters, Robert W.

    1992-01-01

    The computational qualities of high order spatially accurate methods for the finite volume solution of the Euler equations are presented. Two dimensional essentially non-oscillatory (ENO), k-exact, and 'dimension by dimension' ENO reconstruction operators are discussed and compared in terms of reconstruction and solution accuracy, computational cost and oscillatory behavior in supersonic flows with shocks. Inherent steady state convergence difficulties are demonstrated for adaptive stencil algorithms. An exact solution to the heat equation is used to determine reconstruction error, and the computational intensity is reflected in operation counts. Standard MUSCL differencing is included for comparison. Numerical experiments presented include the Ringleb flow for numerical accuracy and a shock reflection problem. A vortex-shock interaction demonstrates the ability of the ENO scheme to excel in simulating unsteady high-frequency flow physics.

  18. Toward Accurate and Quantitative Comparative Metagenomics

    PubMed Central

    Nayfach, Stephen; Pollard, Katherine S.

    2016-01-01

    Shotgun metagenomics and computational analysis are used to compare the taxonomic and functional profiles of microbial communities. Leveraging this approach to understand roles of microbes in human biology and other environments requires quantitative data summaries whose values are comparable across samples and studies. Comparability is currently hampered by the use of abundance statistics that do not estimate a meaningful parameter of the microbial community and biases introduced by experimental protocols and data-cleaning approaches. Addressing these challenges, along with improving study design, data access, metadata standardization, and analysis tools, will enable accurate comparative metagenomics. We envision a future in which microbiome studies are replicable and new metagenomes are easily and rapidly integrated with existing data. Only then can the potential of metagenomics for predictive ecological modeling, well-powered association studies, and effective microbiome medicine be fully realized. PMID:27565341

  19. Obtaining accurate translations from expressed sequence tags.

    PubMed

    Wasmuth, James; Blaxter, Mark

    2009-01-01

    The genomes of an increasing number of species are being investigated through the generation of expressed sequence tags (ESTs). However, ESTs are prone to sequencing errors and typically define incomplete transcripts, making downstream annotation difficult. Annotation would be greatly improved with robust polypeptide translations. Many current solutions for EST translation require a large number of full-length gene sequences for training purposes, a resource that is not available for the majority of EST projects. As part of our ongoing EST programs investigating these "neglected" genomes, we have developed a polypeptide prediction pipeline, prot4EST. It incorporates freely available software to produce final translations that are more accurate than those derived from any single method. We describe how this integrated approach goes a long way to overcoming the deficit in training data.

  20. Accurate radio positions with the Tidbinbilla interferometer

    NASA Technical Reports Server (NTRS)

    Batty, M. J.; Gulkis, S.; Jauncey, D. L.; Rayner, P. T.

    1979-01-01

    The Tidbinbilla interferometer (Batty et al., 1977) is designed specifically to provide accurate radio position measurements of compact radio sources in the Southern Hemisphere with high sensitivity. The interferometer uses the 26-m and 64-m antennas of the Deep Space Network at Tidbinbilla, near Canberra. The two antennas are separated by 200 m on a north-south baseline. By utilizing the existing antennas and the low-noise traveling-wave masers at 2.29 GHz, it has been possible to produce a high-sensitivity instrument with a minimum of capital expenditure. The north-south baseline ensures that a good range of UV coverage is obtained, so that sources lying in the declination range between about -80 and +30 deg may be observed with nearly orthogonal projected baselines of no less than about 1000 lambda. The instrument also provides high-accuracy flux density measurements for compact radio sources.

  1. Magnetic ranging tool accurately guides replacement well

    SciTech Connect

    Lane, J.B.; Wesson, J.P. )

    1992-12-21

    This paper reports on magnetic ranging surveys and directional drilling technology which accurately guided a replacement well bore to intersect a leaking gas storage well with casing damage. The second well bore was then used to pump cement into the original leaking casing shoe. The repair well bore kicked off from the surface hole, bypassed casing damage in the middle of the well, and intersected the damaged well near the casing shoe. The repair well was subsequently completed in the gas storage zone near the original well bore, salvaging the valuable bottom hole location in the reservoir. This method would prevent the loss of storage gas, and it would prevent a potential underground blowout that could permanently damage the integrity of the storage field.

  2. The high cost of accurate knowledge.

    PubMed

    Sutcliffe, Kathleen M; Weber, Klaus

    2003-05-01

    Many business thinkers believe it's the role of senior managers to scan the external environment to monitor contingencies and constraints, and to use that precise knowledge to modify the company's strategy and design. As these thinkers see it, managers need accurate and abundant information to carry out that role. According to that logic, it makes sense to invest heavily in systems for collecting and organizing competitive information. Another school of pundits contends that, since today's complex information often isn't precise anyway, it's not worth going overboard with such investments. In other words, it's not the accuracy and abundance of information that should matter most to top executives--rather, it's how that information is interpreted. After all, the role of senior managers isn't just to make decisions; it's to set direction and motivate others in the face of ambiguities and conflicting demands. Top executives must interpret information and communicate those interpretations--they must manage meaning more than they must manage information. So which of these competing views is the right one? Research conducted by academics Sutcliffe and Weber found that how accurate senior executives are about their competitive environments is indeed less important for strategy and corresponding organizational changes than the way in which they interpret information about their environments. Investments in shaping those interpretations, therefore, may create a more durable competitive advantage than investments in obtaining and organizing more information. And what kinds of interpretations are most closely linked with high performance? Their research suggests that high performers respond positively to opportunities, yet they aren't overconfident in their abilities to take advantage of those opportunities.

  3. Molecular diagnostics and therapeutics for ectopic pregnancy.

    PubMed

    Tong, Stephen; Skubisz, Monika M; Horne, Andrew W

    2015-02-01

    Ectopic pregnancies are a serious gynaecological emergency that can be fatal. As such, prompt diagnosis and safe timely treatment is essential. Here, we review the literature on the development of molecularly targeted diagnostics and therapeutics for ectopic pregnancy. A blood-based biomarker that accurately identifies an ectopic pregnancy could be used to offer early diagnostic certainty in cases where ultrasound cannot determine the location of the embryo ('a pregnancy of unknown location'). Molecules examined so far can be broadly grouped into biological themes of relevance to reproduction: (i) Fallopian tube (dys)function, (ii) embryo/trophoblast growth, (iii) corpus luteum function, (iv) inflammation, (v) uterine function and (vi) angiogenesis. While a sensitive and specific biomarker for ectopic pregnancy has yet to be identified, it is possible that improvements in platform technologies or a multi-modal biomarker approach may yield an accurate diagnostic biomarker test. Furthermore, with the advent of better imaging technology, the need for a blood-based biomarker test may be superseded by improvements in ultrasound or magnetic resonance imaging technology. There have been some recent preclinical studies describing molecularly targeted therapeutic approaches for ectopic pregnancy. Notably, bench-to-bedside studies have examined the use of combination gefitinib (orally available epidermal growth factor receptor inhibitor) and methotrexate. Preclinical studies suggest that combination gefitinib and methotrexate is highly effective in inducing placental cell death, and is significantly more effective than methotrexate alone. In early human trials, encouraging preliminary efficacy data have shown that combination gefitinib and methotrexate can rapidly resolve tubal ectopic pregnancies, and large extra-tubal ectopic pregnancies. If a large clinical randomized controlled trial confirms these findings, combination gefitinib and methotrexate could become a new

  4. Laboratory procedure for the rheological characterization of slurry suspensions

    SciTech Connect

    Chang, C.Y.

    1996-02-01

    This procedure provides rheology measurements that are more reliable and accurate than those described in the technical procedure PNL-(WTC-006-4). Methods are provided to measure the sweep rheogram and steady shear viscosity with concentric cylinders, to measure the yield stress directly with a shear vane, and to measure the sweep rheogram with parallel plates.

  5. Alternative Refractive Surgery Procedures

    MedlinePlus

    ... LASIK Alternative Refractive Surgery Procedures Laser Surgery Recovery Alternative Refractive Surgery Procedures Dec. 12, 2015 Today's refractive ... that releases controlled amounts of radio frequency (RF) energy, instead of a laser, to apply heat to ...

  6. Cosmetic Procedure Questions

    MedlinePlus

    ... Stretch Marks Sun-damaged Skin Unwanted Hair Unwanted Tattoos Varicose Veins Vitiligo Wrinkles Treatments and Procedures Ambulatory ... Stretch Marks Sun-damaged Skin Unwanted Hair Unwanted Tattoos Varicose Veins Vitiligo Wrinkles Treatments and Procedures Ambulatory ...

  7. Synthetic diagnostic for the beam emission spectroscopy diagnostic using a full optical integration

    NASA Astrophysics Data System (ADS)

    Hausammann, L.; Churchill, R. M.; Shi, L.

    2017-02-01

    The beam emission spectroscopy (BES) diagnostic is used to measure fluctuations of electron density in the edge and core of fusion plasmas, and is a key in understanding turbulence in a plasma reactor. A synthetic BES diagnostic for the turbulence simulation code XGC1 has been developed using a realistic neutral beam model and an optical system easily adaptable to different kinds of tokamaks. The beam is modeled using multiple beam energy components, each one with a fraction of the total energy and their own mass and energy (mono-energetic components). The optical system consists of a lens focusing a bundle of optical fibers and resulting in a 2D measurement. The synthetic diagnostic gives similar correlation functions and behaviour of the turbulences than the usual methods that do not take into account the full 3D optical effects. The results, based on a simulation of XGC1, contain an analysis of the correlation (in space and time), a comparison of different approximations possible and their importance in accurately modeling the BES diagnostic.

  8. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The procedure shall be done in accordance with SAE J1962 “Diagnostic Connector” (JUN92). This incorporation of... part 51. Copies of SAE J1962 may be obtained from the Society of Automotive Engineers, Inc.,...

  9. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The procedure shall be done in accordance with SAE J1962 “Diagnostic Connector” (JUN92). This incorporation of... part 51. Copies of SAE J1962 may be obtained from the Society of Automotive Engineers, Inc.,...

  10. Diagnostic Care: Grade 9. Technology Learning Activity. Teacher Edition. Level 2. Technology Education Series.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This Technology Learning Activity (TLA) on exploring diagnostic care careers for Grade 9 is designed for use in eight class periods. It gives students experience in using standard health care equipment to perform basic diagnostic procedures. This teacher's edition begins with an overview of technology education. The second section describes…

  11. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  12. Patient radiation exposure in diagnostic radiology examinations: an overview. Summary report

    SciTech Connect

    Burkhart, R.L.

    1983-08-01

    The report surveys the published data on entrance skin exposure received by patients during diagnostic radiology examinations. It provides a reference source to aid radiology facilities in determining whether the amount of exposure received by their patients is appropriate for the diagnostic procedures employed.

  13. Approaching system equilibrium with accurate or not accurate feedback information in a two-route system

    NASA Astrophysics Data System (ADS)

    Zhao, Xiao-mei; Xie, Dong-fan; Li, Qi

    2015-02-01

    With the development of intelligent transport system, advanced information feedback strategies have been developed to reduce traffic congestion and enhance the capacity. However, previous strategies provide accurate information to travelers and our simulation results show that accurate information brings negative effects, especially in delay case. Because travelers prefer to the best condition route with accurate information, and delayed information cannot reflect current traffic condition but past. Then travelers make wrong routing decisions, causing the decrease of the capacity and the increase of oscillations and the system deviating from the equilibrium. To avoid the negative effect, bounded rationality is taken into account by introducing a boundedly rational threshold BR. When difference between two routes is less than the BR, routes have equal probability to be chosen. The bounded rationality is helpful to improve the efficiency in terms of capacity, oscillation and the gap deviating from the system equilibrium.

  14. Procedure preparation for ISO 9000 certification

    SciTech Connect

    Klement, R.E.

    1995-11-01

    The Kansas City Division (KCD) produces nonnuclear components for nuclear weapons. The company has operated the plant for the US Department of Energy since 1949. Throughout the history of the plant, procedures were written to reflect the nuclear weapons industry best practices, and the facility built a reputation for producing high quality products. In 1991 a critical process team was asked to use Just In Time principles to determine a better way to administrate procedures. By 1992 the team was successful in implementing a full-time centralized procedure group to handle the creation, coordination, review, resolution, and publication of plant-wide administrative and operating procedures. In 1993 AlliedSignal was commissioned by its President and CEO Larry Bossidy to register all of the world-wide sites under the ISO 9000 quality standard. This presented a formidable challenge for the Kansas City Division. Though the independent third-party auditors conceded during a preassessment that the company did in fact build high quality products, the procedures and procedure system did not accurately reflect the current business practices. The purpose of this paper is to share information about the successful implementation of centralized procedure administration and the re-engineering of the procedure system, leading to successful ISO 9001 certification at AlliedSignal Inc., Kansas City Division.

  15. Planetary Transmission Diagnostics

    NASA Technical Reports Server (NTRS)

    Lewicki, David G. (Technical Monitor); Samuel, Paul D.; Conroy, Joseph K.; Pines, Darryll J.

    2004-01-01

    This report presents a methodology for detecting and diagnosing gear faults in the planetary stage of a helicopter transmission. This diagnostic technique is based on the constrained adaptive lifting algorithm. The lifting scheme, developed by Wim Sweldens of Bell Labs, is a time domain, prediction-error realization of the wavelet transform that allows for greater flexibility in the construction of wavelet bases. Classic lifting analyzes a given signal using wavelets derived from a single fundamental basis function. A number of researchers have proposed techniques for adding adaptivity to the lifting scheme, allowing the transform to choose from a set of fundamental bases the basis that best fits the signal. This characteristic is desirable for gear diagnostics as it allows the technique to tailor itself to a specific transmission by selecting a set of wavelets that best represent vibration signals obtained while the gearbox is operating under healthy-state conditions. However, constraints on certain basis characteristics are necessary to enhance the detection of local wave-form changes caused by certain types of gear damage. The proposed methodology analyzes individual tooth-mesh waveforms from a healthy-state gearbox vibration signal that was generated using the vibration separation (synchronous signal-averaging) algorithm. Each waveform is separated into analysis domains using zeros of its slope and curvature. The bases selected in each analysis domain are chosen to minimize the prediction error, and constrained to have the same-sign local slope and curvature as the original signal. The resulting set of bases is used to analyze future-state vibration signals and the lifting prediction error is inspected. The constraints allow the transform to effectively adapt to global amplitude changes, yielding small prediction errors. However, local wave-form changes associated with certain types of gear damage are poorly adapted, causing a significant change in the

  16. Invasive mycoses: diagnostic challenges.

    PubMed

    Ostrosky-Zeichner, Luis

    2012-01-01

    Despite the availability of newer antifungal drugs, outcomes for patients with invasive fungal infections (IFIs) continue to be poor, in large part due to delayed diagnosis and initiation of appropriate antifungal therapy. Standard histopathologic diagnostic techniques are often untenable in at-risk patients, and culture-based diagnostics typically are too insensitive or nonspecific, or provide results after too long a delay for optimal IFI management. Newer surrogate markers of IFIs with improved sensitivity and specificity are needed to enable earlier diagnosis and, ideally, to provide prognostic information and/or permit therapeutic monitoring. Surrogate assays should also be accessible and easy to implement in the hospital. Several nonculture-based assays of newer surrogates are making their way into the medical setting or are currently under investigation. These new or up-and-coming surrogates include antigens/antibodies (mannan and antimannan antibodies) or fungal metabolites (d-arabinitol) for detection of invasive candidiasis, the Aspergillus cell wall component galactomannan used to detect invasive aspergillosis, or the fungal cell wall component and panfungal marker β-glucan. In addition, progress continues with use of polymerase chain reaction- or other nucleic acid- or molecular-based assays for diagnosis of either specific or generic IFIs, although the various methods must be better standardized before any of these approaches can be more fully implemented into the medical setting. Investigators are also beginning to explore the possibility of combining newer surrogate markers with each other or with more standard diagnostic approaches to improve sensitivity, specificity, and capacity for earlier diagnosis, at a time when fungal burden is still relatively low and more responsive to antifungal therapy.

  17. Diagnostic and vaccine chapter.

    PubMed

    Wolfram, J H; Kokanov, S K; Verkhovsky, O A

    2010-10-01

    The first report in this chapter describes the development of a killed composite vaccine. This killed vaccine is non-infectious to humans, other animals, and the environment. The vaccine has low reactivity, is non-abortive, and does not induce pathomorphological alterations to the organs of vaccinated animals. The second report of this chapter describes the diagnostic value of a competitive enzyme-linked immunosorbent assay for detecting Brucella-specific antibodies and its ability to discriminate vaccinated cattle from infected cattle. The results indicated that the competitive enzyme-linked immunosorbent assay is more sensitive than traditional tests for detecting antibodies to Brucella abortus in naturally and experimentally infected cattle.

  18. Diagnostics for hybrid reactors

    NASA Astrophysics Data System (ADS)

    Orsitto, Francesco Paolo

    2012-06-01

    The Hybrid Reactor(HR) can be considered an attractive actinide-burner or a fusion assisted transmutation for destruction of transuranic(TRU) nuclear waste. The hybrid reactor has two important subsystems: the tokamak neutron source and the blanket which includes a fuel zone where the TRU are placed and a tritium breeding zone. The diagnostic system for a HR must be as simple and robust as possible to monitor and control the plasma scenario, guarantee the protection of the machine and monitor the transmutation.

  19. [Molecular diagnostics in neuropathology].

    PubMed

    Dietmaier, W; Lorenz, J; Riemenschneider, M J

    2015-03-01

    As in only few other areas of oncology, molecular markers in neurooncology have become an integral part of clinical decision-making. This development is driven by a bustling scientific activity exploring the molecular basis and pathogenesis of human brain tumors. In addition, a high percentage of brain tumor patients are included in clinical studies in which molecular markers are assessed and linked with clinical informativeness. First steps towards more differentiated therapeutic strategies against brain tumors have thus been taken. The implementation in the clinical and diagnostic routine requires a detailed knowledge and a close collaboration between all medical disciplines involved.

  20. Diagnostic Antigens of Leishmania.

    DTIC Science & Technology

    1994-01-31

    braziliensis (MHOM/BR/75/M2903), L. chagasi (MJOM/BR/82/BA-2,C 1), L. donovani (MHOMiEt/67iHU3), Leishmania guyanensis (MIHOMJBR/75/M4147), L. infantum (IPT-1...comparative test to a variety of other recombinant Leishmania antigens including L. chagasi hsp70, L. braziliensis hsp83/90, L. braziliensis eIF4A, L...34 4. AD CONTRACT NO: DAMD17-92-C-2082 EC•£ 2 j 994 ’i, L TITLE: DIAGNOSTIC ANTIGENS OF LEISHMANIA L PRINCIPAL INVESTIGATOR: Steven G. Reed, Ph.D

  1. Diagnostics for hybrid reactors

    SciTech Connect

    Orsitto, Francesco Paolo

    2012-06-19

    The Hybrid Reactor(HR) can be considered an attractive actinide-burner or a fusion assisted transmutation for destruction of transuranic(TRU) nuclear waste. The hybrid reactor has two important subsystems: the tokamak neutron source and the blanket which includes a fuel zone where the TRU are placed and a tritium breeding zone. The diagnostic system for a HR must be as simple and robust as possible to monitor and control the plasma scenario, guarantee the protection of the machine and monitor the transmutation.

  2. Higher order accurate partial implicitization: An unconditionally stable fourth-order-accurate explicit numerical technique

    NASA Technical Reports Server (NTRS)

    Graves, R. A., Jr.

    1975-01-01

    The previously obtained second-order-accurate partial implicitization numerical technique used in the solution of fluid dynamic problems was modified with little complication to achieve fourth-order accuracy. The Von Neumann stability analysis demonstrated the unconditional linear stability of the technique. The order of the truncation error was deduced from the Taylor series expansions of the linearized difference equations and was verified by numerical solutions to Burger's equation. For comparison, results were also obtained for Burger's equation using a second-order-accurate partial-implicitization scheme, as well as the fourth-order scheme of Kreiss.

  3. Assessing use of a standardized dental diagnostic terminology in an electronic health record.

    PubMed

    Tokede, Oluwabunmi; White, Joel; Stark, Paul C; Vaderhobli, Ram; Walji, Muhammad F; Ramoni, Rachel; Schoonheim-Klein, Meta; Kimmes, Nicole; Tavares, Anamaria; Kalenderian, Elsbeth

    2013-01-01

    Although standardized terminologies such as the International Classification of Diseases have been in use in medicine for over a century, efforts in the dental profession to standardize dental diagnostic terms have not achieved widespread acceptance. To address this gap, a standardized dental diagnostic terminology, the EZCodes, was developed in 2009. Fifteen dental education institutions in the United States and Europe have implemented the EZCodes dental diagnostic terminology. This article reports on the utilization and valid entry of the EZCodes at three of the dental schools that have adopted this standardized dental diagnostic terminology. Electronic data on the use of procedure codes with diagnostic terms from the three schools over a period from July 2010 to June 2011 were aggregated. The diagnostic term and procedure code pairs were adjudicated by three calibrated dentists. Analyses were conducted to gain insight into the utilization and valid entry of the EZCodes diagnostic terminology in the one-year period. Error proportions in the entry of diagnostic term (and by diagnostic category) were also computed. In the twelve-month period, 29,965 diagnostic terms and 249,411 procedure codes were entered at the three institutions resulting in a utilization proportion of 12 percent. Caries and periodontics were the most frequently used categories. More than 1,000 of the available 1,321 diagnostic terms were never used. Overall, 60.5 percent of the EZCodes entries were found to be valid. The results demonstrate low utilization of EZCodes in an electronic health record and raise the need for specific training of dental providers on the importance of using dental diagnostic terminology and specifically how to use the terms in the electronic record. These findings will serve to increase the use/correct use of the EZCodes dental diagnostic terminology and ultimately create a reliable platform for undertaking clinical, outcomes, and quality improvement-related research.

  4. Accurate stochastic reconstruction of heterogeneous microstructures by limited x-ray tomographic projections.

    PubMed

    Li, Hechao; Kaira, Shashank; Mertens, James; Chawla, Nikhilesh; Jiao, Yang

    2016-12-01

    An accurate knowledge of the complex microstructure of a heterogeneous material is crucial for its performance prediction, prognosis and optimization. X-ray tomography has provided a nondestructive means for microstructure characterization in 3D and 4D (i.e. structural evolution over time), in which a material is typically reconstructed from a large number of tomographic projections using filtered-back-projection (FBP) method or algebraic reconstruction techniques (ART). Here, we present in detail a stochastic optimization procedure that enables one to accurately reconstruct material microstructure from a small number of absorption contrast x-ray tomographic projections. This discrete tomography reconstruction procedure is in contrast to the commonly used FBP and ART, which usually requires thousands of projections for accurate microstructure rendition. The utility of our stochastic procedure is first demonstrated by reconstructing a wide class of two-phase heterogeneous materials including sandstone and hard-particle packing from simulated limited-angle projections in both cone-beam and parallel beam projection geometry. It is then applied to reconstruct tailored Sn-sphere-clay-matrix systems from limited-angle cone-beam data obtained via a lab-scale tomography facility at Arizona State University and parallel-beam synchrotron data obtained at Advanced Photon Source, Argonne National Laboratory. In addition, we examine the information content of tomography data by successively incorporating larger number of projections and quantifying the accuracy of the reconstructions. We show that only a small number of projections (e.g. 20-40, depending on the complexity of the microstructure of interest and desired resolution) are necessary for accurate material reconstructions via our stochastic procedure, which indicates its high efficiency in using limited structural information. The ramifications of the stochastic reconstruction procedure in 4D materials science are also

  5. Diagnostics for studies of novel laser ion acceleration mechanisms

    NASA Astrophysics Data System (ADS)

    Senje, Lovisa; Yeung, Mark; Aurand, Bastian; Kuschel, Stephan; Rödel, Christian; Wagner, Florian; Li, Kun; Dromey, Brendan; Bagnoud, Vincent; Neumayer, Paul; Roth, Markus; Wahlström, Claes-Göran; Zepf, Matthew; Kuehl, Thomas; Jung, Daniel

    2014-11-01

    Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.

  6. Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EAST.

    PubMed

    Zang, Qing; Zhao, Junyu; Yang, Li; Hu, Qingsheng; Xi, Xiaoqi; Dai, Xingxing; Yang, Jianhua; Han, Xiaofeng; Li, Mengting; Hsieh, C L

    2011-06-01

    Recently a new Thomson scattering diagnostic system was upgraded in EAST tokamak experiment using a multipulse Nd:YAG (neodymium-yttrium aluminium garnet) laser and a multipoint observation volumes. This diagnostic uses a new optical laser alignment technique that was made to determine accurately the laser position, and a new lens collection system that enables the measurement of wider plasma's object. A composite control system made we can get the results in several seconds. Furthermore, a new data processing method was adopted for much exact results.

  7. Advances in paper-based point-of-care diagnostics.

    PubMed

    Hu, Jie; Wang, ShuQi; Wang, Lin; Li, Fei; Pingguan-Murphy, Belinda; Lu, Tian Jian; Xu, Feng

    2014-04-15

    Advanced diagnostic technologies, such as polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA), have been widely used in well-equipped laboratories. However, they are not affordable or accessible in resource-limited settings due to the lack of basic infrastructure and/or trained operators. Paper-based diagnostic technologies are affordable, user-friendly, rapid, robust, and scalable for manufacturing, thus holding great potential to deliver point-of-care (POC) diagnostics to resource-limited settings. In this review, we present the working principles and reaction mechanism of paper-based diagnostics, including dipstick assays, lateral flow assays (LFAs), and microfluidic paper-based analytical devices (μPADs), as well as the selection of substrates and fabrication methods. Further, we report the advances in improving detection sensitivity, quantification readout, procedure simplification and multi-functionalization of paper-based diagnostics, and discuss the disadvantages of paper-based diagnostics. We envision that miniaturized and integrated paper-based diagnostic devices with the sample-in-answer-out capability will meet the diverse requirements for diagnosis and treatment monitoring at the POC.

  8. Point-of-care technologies for molecular diagnostics using a drop of blood

    PubMed Central

    Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong

    2014-01-01

    Molecular diagnostics is critical for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor- and time-intensive and expensive, and require highly trained operators. This review discusses the frontiers of point-of-care diagnostic technologies using a drop of blood obtained from a finger-prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. PMID:24525172

  9. Point-of-care technologies for molecular diagnostics using a drop of blood.

    PubMed

    Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong

    2014-03-01

    Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics.

  10. Diagnostic imaging and interventional therapy of hepatocellular carcinoma.

    PubMed

    Palma, L D

    1998-08-01

    Diagnostic imaging has many important roles in the management of patients with hepatocellular carcinoma (HCC). In diagnosis, lipiodol CT (LCT) has been shown to be the most sensitive imaging modality (90-97%) for all sizes of lesions; all other modalities have high sensitivities for lesions 1-3 cm but low sensitivities for lesions < 1 cm (ultrasound 33-37%, conventional CT 20-42% and digital subtraction angiography 40-55%). All imaging modalities understage HCC. Once again LCT is the most accurate method of evaluating the extent of tumour, but even this method does not identify all satellite nodules. Ultrasound has been proposed as a screening method, but this cannot be justified on the basis of its results or cost benefit analysis. Both CT and dynamic MRI play useful roles in evaluating the efficacy and follow-up of patients undergoing chemoembolization (TACE) and percutaneous ethanol injection (PEI). Although surgery remains the best treatment of HCC, it is unsuitable in most of the cases which would be better treated with interventional therapy. This article presents a review of the literature regarding the use of TACE, PEI or a combination of both procedures in the treatment of HCC. A multicentric study has shown that patients with monofocal lesions less than 5 cm in diameter are better treated with PEI, which is therefore a good alternative to the surgical treatment; patients with multifocal lesions (maximum of three lesions) show a better survival with TACE. Combined treatment with TACE and PEI proves to be effective in patients with large HCC.

  11. [Over diagnostic imaging in cardiology].

    PubMed

    Carpeggiani, Clara

    2014-03-01

    Medical imaging is one of the major cause of rising health care costs. Diagnostic imaging has increased more rapidly than any other component of medical care. About 5 billion imaging tests are performed worldwide each year. According to recent estimates, at least one-third of all examinations are partially or totally inappropriate. Two out of 3 imaging tests employ ionizing radiations with radiology or nuclear medicine. The medical use of radiation is the largest man-made source of radiation exposure. Medical X-rays and γ-rays are a proven human carcinogen. The attributable long-term extra-risk of cancer due to diagnostic testing is around 10% in industrialized countries. Cardiologists prescribe and/or directly perform >50% of all imaging examinations, accounting for about two-thirds of the total effective dose given to patients. The dose of common cardiological examinations may be significant: 500 chest X-rays= a stress scintigraphy with sestamibi, 750 chest X-rays= a Multislice Computed Tomography, 1,000 chest X-rays= a coronary angiography and stenting. Unfortunately, few doctors are aware of the level of radiation their patients are exposed to during radiological tests and more intensive use of ionizing testing was not associated with greater awareness. Also as a consequence of unawareness, the rate of inappropriate examinations is unacceptably high in cardiology, even for procedures with high radiation load. Higher exposure doses correspond to higher long-term risks; there are no safe doses, and all doses add up in determining the cumulative risks over a lifetime. Doctors should make every effort so that «each patient should get the right imaging exam, at the right time, with the right radiation dose», as suggested by US Food and Drug Administration in the 2010 initiative to reduce unnecessary radiation exposure from medical imaging. This is best obtained through a systematic implementation of the "3 A's strategy" proposed by the International Atomic Energy

  12. Image Processing Diagnostics: Emphysema

    NASA Astrophysics Data System (ADS)

    McKenzie, Alex

    2009-10-01

    Currently the computerized tomography (CT) scan can detect emphysema sooner than traditional x-rays, but other tests are required to measure more accurately the amount of affected lung. CT scan images show clearly if a patient has emphysema, but is unable by visual scan alone, to quantify the degree of the disease, as it appears merely as subtle, barely distinct, dark spots on the lung. Our goal is to create a software plug-in to interface with existing open source medical imaging software, to automate the process of accurately diagnosing and determining emphysema severity levels in patients. This will be accomplished by performing a number of statistical calculations using data taken from CT scan images of several patients representing a wide range of severity of the disease. These analyses include an examination of the deviation from a normal distribution curve to determine skewness, a commonly used statistical parameter. Our preliminary results show that this method of assessment appears to be more accurate and robust than currently utilized methods which involve looking at percentages of radiodensities in air passages of the lung.

  13. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    SciTech Connect

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  14. Effects of antecedent variables on disruptive behavior and accurate responding in young children in outpatient settings.

    PubMed

    Boelter, Eric W; Wacker, David P; Call, Nathan A; Ringdahl, Joel E; Kopelman, Todd; Gardner, Andrew W

    2007-01-01

    The effects of manipulations of task variables on inaccurate responding and disruption were investigated with 3 children who engaged in noncompliance. With 2 children in an outpatient clinic, task directives were first manipulated to identify directives that guided accurate responding; then, additional dimensions of the task were manipulated to evaluate their influence on disruptive behavior. With a 3rd child, similar procedures were employed at school. Results showed one-step directives set the occasion for accurate responding and that other dimensions of the task (e.g., preference) functioned as motivating operations for negative reinforcement.

  15. Crew procedures development techniques

    NASA Technical Reports Server (NTRS)

    Arbet, J. D.; Benbow, R. L.; Hawk, M. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.

    1975-01-01

    The study developed requirements, designed, developed, checked out and demonstrated the Procedures Generation Program (PGP). The PGP is a digital computer program which provides a computerized means of developing flight crew procedures based on crew action in the shuttle procedures simulator. In addition, it provides a real time display of procedures, difference procedures, performance data and performance evaluation data. Reconstruction of displays is possible post-run. Data may be copied, stored on magnetic tape and transferred to the document processor for editing and documentation distribution.

  16. NIO1 diagnostics

    NASA Astrophysics Data System (ADS)

    Zaniol, B.; Barbisan, M.; Cavenago, M.; De Muri, M.; Mimo, A.; Pasqualotto, R.; Serianni, G.

    2015-04-01

    The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm2. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

  17. Laboratory Diagnostics of Botulism

    PubMed Central

    Lindström, Miia; Korkeala, Hannu

    2006-01-01

    Botulism is a potentially lethal paralytic disease caused by botulinum neurotoxin. Human pathogenic neurotoxins of types A, B, E, and F are produced by a diverse group of anaerobic spore-forming bacteria, including Clostridium botulinum groups I and II, Clostridium butyricum, and Clostridium baratii. The routine laboratory diagnostics of botulism is based on the detection of botulinum neurotoxin in the patient. Detection of toxin-producing clostridia in the patient and/or the vehicle confirms the diagnosis. The neurotoxin detection is based on the mouse lethality assay. Sensitive and rapid in vitro assays have been developed, but they have not yet been appropriately validated on clinical and food matrices. Culture methods for C. botulinum are poorly developed, and efficient isolation and identification tools are lacking. Molecular techniques targeted to the neurotoxin genes are ideal for the detection and identification of C. botulinum, but they do not detect biologically active neurotoxin and should not be used alone. Apart from rapid diagnosis, the laboratory diagnostics of botulism should aim at increasing our understanding of the epidemiology and prevention of the disease. Therefore, the toxin-producing organisms should be routinely isolated from the patient and the vehicle. The physiological group and genetic traits of the isolates should be determined. PMID:16614251

  18. [Diagnostic Management of Exophthalmos].

    PubMed

    Klingenstein, A; Hintschich, C

    2017-01-01

    Exophthalmos is a common and important symptom in orbital consultation. It can be either uni- or bilateral. A wide spectrum of benign and malignant diseases has to be considered and evaluated for differential diagnosis, in order to maintain complete ocular function and to lead the patient to adequate therapy. Exophthalmos can be accompanied by variable symptoms, ranging from neurogenic or myogenic to corneal alterations. Symptoms at presentation depend on the underlying disease and may manifest systemically. Interdisciplinary teamwork is essential for diagnostics and therapy of exophthalmos. In addition to ophthalmological routine diagnostics, various supplementary examinations are available which are of importance for disease monitoring. Exact radiological imaging is important for the detailed visualisation of the pathology, surgery as well as treatment planning. Magnetic resonance imaging (MRI) and computed tomography (CT) are the standard imaging techniques used. Contrast enhancement and specific sequences can answer specific problems in detail. Combined positron emission tomography (PET) with CT permits evaluation of metabolic and morphological data and is employed in diagnosis of meningioma, lymphoma and metastases. In summary, the reader should learn important differential diagnoses and accompanying symptoms of exophthalmos, thus enabling essential clinical examinations and adequate imaging.

  19. NIO1 diagnostics

    SciTech Connect

    Zaniol, B. Barbisan, M.; Pasqualotto, R.; Serianni, G.; Cavenago, M.; De Muri, M.; Mimo, A.

    2015-04-08

    The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

  20. Thioaptamer Diagnostic System (TDS)

    NASA Technical Reports Server (NTRS)

    Yang, Xianbin

    2015-01-01

    AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

  1. Diagnostic Oligonucleotide Microarray Fingerprinting of Bacillus Isolates

    SciTech Connect

    Chandler, Darrell P.; Alferov, Oleg; Chernov, Boris; Daly, Don S.; Golova, Julia; Perov, Alexander N.; Protic, Miroslava; Robison, Richard; Shipma, Matthew; White, Amanda M.; Willse, Alan R.

    2006-01-01

    A diagnostic, genome-independent microbial fingerprinting method using DNA oligonucleotide microarrays was used for high-resolution differentiation between closely related Bacillus strains, including two strains of Bacillus anthracis that are monomorphic (indistinguishable) via amplified fragment length polymorphism fingerprinting techniques. Replicated hybridizations on 391-probe nonamer arrays were used to construct a prototype fingerprint library for quantitative comparisons. Descriptive analysis of the fingerprints, including phylogenetic reconstruction, is consistent with previous taxonomic organization of the genus. Newly developed statistical analysis methods were used to quantitatively compare and objectively confirm apparent differences in microarray fingerprints with the statistical rigor required for microbial forensics and clinical diagnostics. These data suggest that a relatively simple fingerprinting microarray and statistical analysis method can differentiate between species in the Bacillus cereus complex, and between strains of B. anthracis. A synthetic DNA standard was used to understand underlying microarray and process-level variability, leading to specific recommendations for the development of a standard operating procedure and/or continued technology enhancements for microbial forensics and diagnostics.

  2. Interventional MSK procedures: the hip

    PubMed Central

    Lefebvre, Guillaume; Cockenpot, Eric; Chastanet, Patrick; Cotten, Anne

    2016-01-01

    Percutaneous musculoskeletal procedures are widely accepted as low invasive, highly effective, efficient and safe methods in a vast amount of hip pathologies either in diagnostic or in therapeutic management. Hip intra-articular injections are used for the symptomatic treatment of osteoarthritis. Peritendinous or intrabursal corticosteroid injections can be used for the symptomatic treatment of greater trochanteric pain syndrome and anterior iliopsoas impingement. In past decades, the role of interventional radiology has rapidly increased in metastatic disease, thanks to the development of many ablative techniques. Image-guided percutaneous ablation of skeletal metastases provides a minimally invasive treatment option that appears to be a safe and effective palliative treatment for localized painful lytic lesion. Methods of tumour destruction based on temperature, such as radiofrequency ablation (RFA) and cryotherapy, are performed for the management of musculoskeletal metastases. MR-guided focused ultrasound surgery provides a non-invasive alternative to these ablative methods. Cementoplasty is now widely used for pain management and consolidation of acetabular metastases and can be combined with RFA. RFA is also used to treat benign tumours, namely osteoid osteomas. New interventional procedures such as percutaneous screw fixation are also proposed to treat non-displaced or minimally displaced acetabular roof fractures. PMID:26317896

  3. Does a pneumotach accurately characterize voice function?

    NASA Astrophysics Data System (ADS)

    Walters, Gage; Krane, Michael

    2016-11-01

    A study is presented which addresses how a pneumotach might adversely affect clinical measurements of voice function. A pneumotach is a device, typically a mask, worn over the mouth, in order to measure time-varying glottal volume flow. By measuring the time-varying difference in pressure across a known aerodynamic resistance element in the mask, the glottal volume flow waveform is estimated. Because it adds aerodynamic resistance to the vocal system, there is some concern that using a pneumotach may not accurately portray the behavior of the voice. To test this hypothesis, experiments were performed in a simplified airway model with the principal dimensions of an adult human upper airway. A compliant constriction, fabricated from silicone rubber, modeled the vocal folds. Variations of transglottal pressure, time-averaged volume flow, model vocal fold vibration amplitude, and radiated sound with subglottal pressure were performed, with and without the pneumotach in place, and differences noted. Acknowledge support of NIH Grant 2R01DC005642-10A1.

  4. Accurate thermoplasmonic simulation of metallic nanoparticles

    NASA Astrophysics Data System (ADS)

    Yu, Da-Miao; Liu, Yan-Nan; Tian, Fa-Lin; Pan, Xiao-Min; Sheng, Xin-Qing

    2017-01-01

    Thermoplasmonics leads to enhanced heat generation due to the localized surface plasmon resonances. The measurement of heat generation is fundamentally a complicated task, which necessitates the development of theoretical simulation techniques. In this paper, an efficient and accurate numerical scheme is proposed for applications with complex metallic nanostructures. Light absorption and temperature increase are, respectively, obtained by solving the volume integral equation (VIE) and the steady-state heat diffusion equation through the method of moments (MoM). Previously, methods based on surface integral equations (SIEs) were utilized to obtain light absorption. However, computing light absorption from the equivalent current is as expensive as O(NsNv), where Ns and Nv, respectively, denote the number of surface and volumetric unknowns. Our approach reduces the cost to O(Nv) by using VIE. The accuracy, efficiency and capability of the proposed scheme are validated by multiple simulations. The simulations show that our proposed method is more efficient than the approach based on SIEs under comparable accuracy, especially for the case where many incidents are of interest. The simulations also indicate that the temperature profile can be tuned by several factors, such as the geometry configuration of array, beam direction, and light wavelength.

  5. Accurate method for computing correlated color temperature.

    PubMed

    Li, Changjun; Cui, Guihua; Melgosa, Manuel; Ruan, Xiukai; Zhang, Yaoju; Ma, Long; Xiao, Kaida; Luo, M Ronnier

    2016-06-27

    For the correlated color temperature (CCT) of a light source to be estimated, a nonlinear optimization problem must be solved. In all previous methods available to compute CCT, the objective function has only been approximated, and their predictions have achieved limited accuracy. For example, different unacceptable CCT values have been predicted for light sources located on the same isotemperature line. In this paper, we propose to compute CCT using the Newton method, which requires the first and second derivatives of the objective function. Following the current recommendation by the International Commission on Illumination (CIE) for the computation of tristimulus values (summations at 1 nm steps from 360 nm to 830 nm), the objective function and its first and second derivatives are explicitly given and used in our computations. Comprehensive tests demonstrate that the proposed method, together with an initial estimation of CCT using Robertson's method [J. Opt. Soc. Am. 58, 1528-1535 (1968)], gives highly accurate predictions below 0.0012 K for light sources with CCTs ranging from 500 K to 106 K.

  6. Accurate Theoretical Thermochemistry for Fluoroethyl Radicals.

    PubMed

    Ganyecz, Ádám; Kállay, Mihály; Csontos, József

    2017-02-09

    An accurate coupled-cluster (CC) based model chemistry was applied to calculate reliable thermochemical quantities for hydrofluorocarbon derivatives including radicals 1-fluoroethyl (CH3-CHF), 1,1-difluoroethyl (CH3-CF2), 2-fluoroethyl (CH2F-CH2), 1,2-difluoroethyl (CH2F-CHF), 2,2-difluoroethyl (CHF2-CH2), 2,2,2-trifluoroethyl (CF3-CH2), 1,2,2,2-tetrafluoroethyl (CF3-CHF), and pentafluoroethyl (CF3-CF2). The model chemistry used contains iterative triple and perturbative quadruple excitations in CC theory, as well as scalar relativistic and diagonal Born-Oppenheimer corrections. To obtain heat of formation values with better than chemical accuracy perturbative quadruple excitations and scalar relativistic corrections were inevitable. Their contributions to the heats of formation steadily increase with the number of fluorine atoms in the radical reaching 10 kJ/mol for CF3-CF2. When discrepancies were found between the experimental and our values it was always possible to resolve the issue by recalculating the experimental result with currently recommended auxiliary data. For each radical studied here this study delivers the best heat of formation as well as entropy data.

  7. Accurate, reliable prototype earth horizon sensor head

    NASA Technical Reports Server (NTRS)

    Schwarz, F.; Cohen, H.

    1973-01-01

    The design and performance is described of an accurate and reliable prototype earth sensor head (ARPESH). The ARPESH employs a detection logic 'locator' concept and horizon sensor mechanization which should lead to high accuracy horizon sensing that is minimally degraded by spatial or temporal variations in sensing attitude from a satellite in orbit around the earth at altitudes in the 500 km environ 1,2. An accuracy of horizon location to within 0.7 km has been predicted, independent of meteorological conditions. This corresponds to an error of 0.015 deg-at 500 km altitude. Laboratory evaluation of the sensor indicates that this accuracy is achieved. First, the basic operating principles of ARPESH are described; next, detailed design and construction data is presented and then performance of the sensor under laboratory conditions in which the sensor is installed in a simulator that permits it to scan over a blackbody source against background representing the earth space interface for various equivalent plant temperatures.

  8. Accurate methods for large molecular systems.

    PubMed

    Gordon, Mark S; Mullin, Jonathan M; Pruitt, Spencer R; Roskop, Luke B; Slipchenko, Lyudmila V; Boatz, Jerry A

    2009-07-23

    Three exciting new methods that address the accurate prediction of processes and properties of large molecular systems are discussed. The systematic fragmentation method (SFM) and the fragment molecular orbital (FMO) method both decompose a large molecular system (e.g., protein, liquid, zeolite) into small subunits (fragments) in very different ways that are designed to both retain the high accuracy of the chosen quantum mechanical level of theory while greatly reducing the demands on computational time and resources. Each of these methods is inherently scalable and is therefore eminently capable of taking advantage of massively parallel computer hardware while retaining the accuracy of the corresponding electronic structure method from which it is derived. The effective fragment potential (EFP) method is a sophisticated approach for the prediction of nonbonded and intermolecular interactions. Therefore, the EFP method provides a way to further reduce the computational effort while retaining accuracy by treating the far-field interactions in place of the full electronic structure method. The performance of the methods is demonstrated using applications to several systems, including benzene dimer, small organic species, pieces of the alpha helix, water, and ionic liquids.

  9. Accurate equilibrium structures for piperidine and cyclohexane.

    PubMed

    Demaison, Jean; Craig, Norman C; Groner, Peter; Écija, Patricia; Cocinero, Emilio J; Lesarri, Alberto; Rudolph, Heinz Dieter

    2015-03-05

    Extended and improved microwave (MW) measurements are reported for the isotopologues of piperidine. New ground state (GS) rotational constants are fitted to MW transitions with quartic centrifugal distortion constants taken from ab initio calculations. Predicate values for the geometric parameters of piperidine and cyclohexane are found from a high level of ab initio theory including adjustments for basis set dependence and for correlation of the core electrons. Equilibrium rotational constants are obtained from GS rotational constants corrected for vibration-rotation interactions and electronic contributions. Equilibrium structures for piperidine and cyclohexane are fitted by the mixed estimation method. In this method, structural parameters are fitted concurrently to predicate parameters (with appropriate uncertainties) and moments of inertia (with uncertainties). The new structures are regarded as being accurate to 0.001 Å and 0.2°. Comparisons are made between bond parameters in equatorial piperidine and cyclohexane. Another interesting result of this study is that a structure determination is an effective way to check the accuracy of the ground state experimental rotational constants.

  10. Accurate lineshape spectroscopy and the Boltzmann constant

    PubMed Central

    Truong, G.-W.; Anstie, J. D.; May, E. F.; Stace, T. M.; Luiten, A. N.

    2015-01-01

    Spectroscopy has an illustrious history delivering serendipitous discoveries and providing a stringent testbed for new physical predictions, including applications from trace materials detection, to understanding the atmospheres of stars and planets, and even constraining cosmological models. Reaching fundamental-noise limits permits optimal extraction of spectroscopic information from an absorption measurement. Here, we demonstrate a quantum-limited spectrometer that delivers high-precision measurements of the absorption lineshape. These measurements yield a very accurate measurement of the excited-state (6P1/2) hyperfine splitting in Cs, and reveals a breakdown in the well-known Voigt spectral profile. We develop a theoretical model that accounts for this breakdown, explaining the observations to within the shot-noise limit. Our model enables us to infer the thermal velocity dispersion of the Cs vapour with an uncertainty of 35 p.p.m. within an hour. This allows us to determine a value for Boltzmann's constant with a precision of 6 p.p.m., and an uncertainty of 71 p.p.m. PMID:26465085

  11. Accurate upper body rehabilitation system using kinect.

    PubMed

    Sinha, Sanjana; Bhowmick, Brojeshwar; Chakravarty, Kingshuk; Sinha, Aniruddha; Das, Abhijit

    2016-08-01

    The growing importance of Kinect as a tool for clinical assessment and rehabilitation is due to its portability, low cost and markerless system for human motion capture. However, the accuracy of Kinect in measuring three-dimensional body joint center locations often fails to meet clinical standards of accuracy when compared to marker-based motion capture systems such as Vicon. The length of the body segment connecting any two joints, measured as the distance between three-dimensional Kinect skeleton joint coordinates, has been observed to vary with time. The orientation of the line connecting adjoining Kinect skeletal coordinates has also been seen to differ from the actual orientation of the physical body segment. Hence we have proposed an optimization method that utilizes Kinect Depth and RGB information to search for the joint center location that satisfies constraints on body segment length and as well as orientation. An experimental study have been carried out on ten healthy participants performing upper body range of motion exercises. The results report 72% reduction in body segment length variance and 2° improvement in Range of Motion (ROM) angle hence enabling to more accurate measurements for upper limb exercises.

  12. Noninvasive hemoglobin monitoring: how accurate is enough?

    PubMed

    Rice, Mark J; Gravenstein, Nikolaus; Morey, Timothy E

    2013-10-01

    Evaluating the accuracy of medical devices has traditionally been a blend of statistical analyses, at times without contextualizing the clinical application. There have been a number of recent publications on the accuracy of a continuous noninvasive hemoglobin measurement device, the Masimo Radical-7 Pulse Co-oximeter, focusing on the traditional statistical metrics of bias and precision. In this review, which contains material presented at the Innovations and Applications of Monitoring Perfusion, Oxygenation, and Ventilation (IAMPOV) Symposium at Yale University in 2012, we critically investigated these metrics as applied to the new technology, exploring what is required of a noninvasive hemoglobin monitor and whether the conventional statistics adequately answer our questions about clinical accuracy. We discuss the glucose error grid, well known in the glucose monitoring literature, and describe an analogous version for hemoglobin monitoring. This hemoglobin error grid can be used to evaluate the required clinical accuracy (±g/dL) of a hemoglobin measurement device to provide more conclusive evidence on whether to transfuse an individual patient. The important decision to transfuse a patient usually requires both an accurate hemoglobin measurement and a physiologic reason to elect transfusion. It is our opinion that the published accuracy data of the Masimo Radical-7 is not good enough to make the transfusion decision.

  13. Fast and accurate exhaled breath ammonia measurement.

    PubMed

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A; Risby, Terence H

    2014-06-11

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations.

  14. Accurate Fission Data for Nuclear Safety

    NASA Astrophysics Data System (ADS)

    Solders, A.; Gorelov, D.; Jokinen, A.; Kolhinen, V. S.; Lantz, M.; Mattera, A.; Penttilä, H.; Pomp, S.; Rakopoulos, V.; Rinta-Antila, S.

    2014-05-01

    The Accurate fission data for nuclear safety (AlFONS) project aims at high precision measurements of fission yields, using the renewed IGISOL mass separator facility in combination with a new high current light ion cyclotron at the University of Jyväskylä. The 30 MeV proton beam will be used to create fast and thermal neutron spectra for the study of neutron induced fission yields. Thanks to a series of mass separating elements, culminating with the JYFLTRAP Penning trap, it is possible to achieve a mass resolving power in the order of a few hundred thousands. In this paper we present the experimental setup and the design of a neutron converter target for IGISOL. The goal is to have a flexible design. For studies of exotic nuclei far from stability a high neutron flux (1012 neutrons/s) at energies 1 - 30 MeV is desired while for reactor applications neutron spectra that resembles those of thermal and fast nuclear reactors are preferred. It is also desirable to be able to produce (semi-)monoenergetic neutrons for benchmarking and to study the energy dependence of fission yields. The scientific program is extensive and is planed to start in 2013 with a measurement of isomeric yield ratios of proton induced fission in uranium. This will be followed by studies of independent yields of thermal and fast neutron induced fission of various actinides.

  15. A procedure to analyze nonlinear density waves in Saturn's rings using several occultation profiles

    NASA Astrophysics Data System (ADS)

    Rappaport, Nicole J.; Longaretti, Pierre-Yves; French, Richard G.; Marouf, Essam A.; McGhee, Colleen A.

    2009-01-01

    procedure constitutes the first step in our planned analysis of the density waves of Saturn's rings. It is very accurate and efficient in the far-wave region. However, improvements are required within the first wavelength. The ways in which this method can be used to establish diagnostics of ring physics are outlined.

  16. An overview of nuclear medicine imaging procedures.

    PubMed

    Hogg, Peter; Lawson, Richard

    2015-11-25

    Nuclear medicine imaging is not generally well understood by nurses who work outside this area. Consequently, nurses can find themselves unable to answer patients' questions about nuclear medicine imaging procedures or give them proper information before they attend for a test. This article aims to explain what is involved in some common diagnostic nuclear medicine imaging procedures so that nurses are able to discuss this with patients. It also addresses some common issues about radiation protection that nurses might encounter in their usual working routine. The article includes links to videos showing some typical nuclear medicine imaging procedures from a patient's point of view and links to an e-Learning for Healthcare online resource that provides detailed information for nurses.

  17. Breast MRI in nonpalpable breast lesions: a randomized trial with diagnostic and therapeutic outcome – MONET – study

    PubMed Central

    Peters, Nicky HGM; Borel Rinkes, Inne HM; Mali, Willem PTM; van den Bosch, Maurice AAJ; Storm, Remmert K; Plaisier, Peter W; de Boer, Erwin; van Overbeeke, Adriaan J; Peeters, Petra HM

    2007-01-01

    Background In recent years there has been an increasing interest in MRI as a non-invasive diagnostic modality for the work-up of suspicious breast lesions. The additional value of Breast MRI lies mainly in its capacity to detect multicentric and multifocal disease, to detect invasive components in ductal carcinoma in situ lesions and to depict the tumor in a 3-dimensional image. Breast MRI therefore has the potential to improve the diagnosis and provide better preoperative staging and possibly surgical care in patients with breast cancer. The aim of our study is to assess whether performing contrast enhanced Breast MRI can reduce the number of surgical procedures due to better preoperative staging and whether a subgroup of women with suspicious nonpalpable breast lesions can be identified in which the combination of mammography, ultrasound and state-of-the-art contrast-enhanced Breast MRI can provide a definite diagnosis. Methods/Design The MONET – study (MR mammography Of Nonpalpable BrEast Tumors) is a randomized controlled trial with diagnostic and therapeutic endpoints. We aim to include 500 patients with nonpalpable suspicious breast lesions who are referred for biopsy. With this number of patients, the expected 12% reduction in surgical procedures due to more accurate preoperative staging with Breast MRI can be detected with a high power (90%). The secondary outcome is the positive and negative predictive value of contrast enhanced Breast MRI. If the predictive values are deemed sufficiently close to those for large core biopsy then the latter, invasive, procedure could possibly be avoided in some women. The rationale, study design and the baseline characteristics of the first 100 included patients are described. Trial registration Study protocol number NCT00302120 PMID:18045470

  18. Important Nearby Galaxies without Accurate Distances

    NASA Astrophysics Data System (ADS)

    McQuinn, Kristen

    2014-10-01

    The Spitzer Infrared Nearby Galaxies Survey (SINGS) and its offspring programs (e.g., THINGS, HERACLES, KINGFISH) have resulted in a fundamental change in our view of star formation and the ISM in galaxies, and together they represent the most complete multi-wavelength data set yet assembled for a large sample of nearby galaxies. These great investments of observing time have been dedicated to the goal of understanding the interstellar medium, the star formation process, and, more generally, galactic evolution at the present epoch. Nearby galaxies provide the basis for which we interpret the distant universe, and the SINGS sample represents the best studied nearby galaxies.Accurate distances are fundamental to interpreting observations of galaxies. Surprisingly, many of the SINGS spiral galaxies have numerous distance estimates resulting in confusion. We can rectify this situation for 8 of the SINGS spiral galaxies within 10 Mpc at a very low cost through measurements of the tip of the red giant branch. The proposed observations will provide an accuracy of better than 0.1 in distance modulus. Our sample includes such well known galaxies as M51 (the Whirlpool), M63 (the Sunflower), M104 (the Sombrero), and M74 (the archetypal grand design spiral).We are also proposing coordinated parallel WFC3 UV observations of the central regions of the galaxies, rich with high-mass UV-bright stars. As a secondary science goal we will compare the resolved UV stellar populations with integrated UV emission measurements used in calibrating star formation rates. Our observations will complement the growing HST UV atlas of high resolution images of nearby galaxies.

  19. Accurate paleointensities - the multi-method approach

    NASA Astrophysics Data System (ADS)

    de Groot, Lennart

    2016-04-01

    The accuracy of models describing rapid changes in the geomagnetic field over the past millennia critically depends on the availability of reliable paleointensity estimates. Over the past decade methods to derive paleointensities from lavas (the only recorder of the geomagnetic field that is available all over the globe and through geologic times) have seen significant improvements and various alternative techniques were proposed. The 'classical' Thellier-style approach was optimized and selection criteria were defined in the 'Standard Paleointensity Definitions' (Paterson et al, 2014). The Multispecimen approach was validated and the importance of additional tests and criteria to assess Multispecimen results must be emphasized. Recently, a non-heating, relative paleointensity technique was proposed -the pseudo-Thellier protocol- which shows great potential in both accuracy and efficiency, but currently lacks a solid theoretical underpinning. Here I present work using all three of the aforementioned paleointensity methods on suites of young lavas taken from the volcanic islands of Hawaii, La Palma, Gran Canaria, Tenerife, and Terceira. Many of the sampled cooling units are <100 years old, the actual field strength at the time of cooling is therefore reasonably well known. Rather intuitively, flows that produce coherent results from two or more different paleointensity methods yield the most accurate estimates of the paleofield. Furthermore, the results for some flows pass the selection criteria for one method, but fail in other techniques. Scrutinizing and combing all acceptable results yielded reliable paleointensity estimates for 60-70% of all sampled cooling units - an exceptionally high success rate. This 'multi-method paleointensity approach' therefore has high potential to provide the much-needed paleointensities to improve geomagnetic field models for the Holocene.

  20. Accurate glucose detection in a small etalon

    NASA Astrophysics Data System (ADS)

    Martini, Joerg; Kuebler, Sebastian; Recht, Michael; Torres, Francisco; Roe, Jeffrey; Kiesel, Peter; Bruce, Richard

    2010-02-01

    We are developing a continuous glucose monitor for subcutaneous long-term implantation. This detector contains a double chamber Fabry-Perot-etalon that measures the differential refractive index (RI) between a reference and a measurement chamber at 850 nm. The etalon chambers have wavelength dependent transmission maxima which dependent linearly on the RI of their contents. An RI difference of ▵n=1.5.10-6 changes the spectral position of a transmission maximum by 1pm in our measurement. By sweeping the wavelength of a single-mode Vertical-Cavity-Surface-Emitting-Laser (VCSEL) linearly in time and detecting the maximum transmission peaks of the etalon we are able to measure the RI of a liquid. We have demonstrated accuracy of ▵n=+/-3.5.10-6 over a ▵n-range of 0 to 1.75.10-4 and an accuracy of 2% over a ▵nrange of 1.75.10-4 to 9.8.10-4. The accuracy is primarily limited by the reference measurement. The RI difference between the etalon chambers is made specific to glucose by the competitive, reversible release of Concanavalin A (ConA) from an immobilized dextran matrix. The matrix and ConA bound to it, is positioned outside the optical detection path. ConA is released from the matrix by reacting with glucose and diffuses into the optical path to change the RI in the etalon. Factors such as temperature affect the RI in measurement and detection chamber equally but do not affect the differential measurement. A typical standard deviation in RI is +/-1.4.10-6 over the range 32°C to 42°C. The detector enables an accurate glucose specific concentration measurement.