Science.gov

Sample records for accurate diagnostic procedures

  1. Hospital discharge diagnostic and procedure codes for upper gastro-intestinal cancer: how accurate are they?

    PubMed Central

    2012-01-01

    Background Population-level health administrative datasets such as hospital discharge data are used increasingly to evaluate health services and outcomes of care. However information about the accuracy of Australian discharge data in identifying cancer, associated procedures and comorbidity is limited. The Admitted Patients Data Collection (APDC) is a census of inpatient hospital discharges in the state of New South Wales (NSW). Our aim was to assess the accuracy of the APDC in identifying upper gastro-intestinal (upper GI) cancer cases, procedures for associated curative resection and comorbidities at the time of admission compared to data abstracted from medical records (the ‘gold standard’). Methods We reviewed the medical records of 240 patients with an incident upper GI cancer diagnosis derived from a clinical database in one NSW area health service from July 2006 to June 2007. Extracted case record data was matched to APDC discharge data to determine sensitivity, positive predictive value (PPV) and agreement between the two data sources (κ-coefficient). Results The accuracy of the APDC diagnostic codes in identifying site-specific incident cancer ranged from 80-95% sensitivity. This was comparable to the accuracy of APDC procedure codes in identifying curative resection for upper GI cancer. PPV ranged from 42-80% for cancer diagnosis and 56-93% for curative surgery. Agreement between the data sources was >0.72 for most cancer diagnoses and curative resections. However, APDC discharge data was less accurate in reporting common comorbidities - for each condition, sensitivity ranged from 9-70%, whilst agreement ranged from κ = 0.64 for diabetes down to κ < 0.01 for gastro-oesophageal reflux disorder. Conclusions Identifying incident cases of upper GI cancer and curative resection from hospital administrative data is satisfactory but under-ascertained. Linkage of multiple population-health datasets is advisable to maximise case ascertainment and

  2. Diagnostic Procedures of Itch.

    PubMed

    Reich, Adam; Szepietowski, Jacek C

    2016-01-01

    A complex and multifactorial pathogenesis of itch makes the proper diagnosis of underlying disease a difficult and challenging clinical problem. The examination of every patient with itch should be started by gathering an accurate history. During the anamnesis it is important to obtain data about the beginning of the appearance of symptoms, its location, diurnal variation, and the factors influencing itch perception. After careful anamnesis the patient should undergo a detailed physical examination, with particular attention to the skin in order to look for any signs of skin lesions. Special attention should be paid to distinguish the primary lesion from the changes resulting from scratching. In patients in whom the etiology of the itch cannot be identified on the basis of the medical examination, a panel of primary screen laboratory examination may be required, and if necessary, depending on the results of basic laboratory results and data from medical history, additional diagnostic tests should be considered. In patients in whom an organic cause of itching has not been established, itch is most likely of undetermined origin; however, psychogenic causes should also be suspected and ruled out. In conclusion, it could be stated that itch is a common symptom of many skin diseases, systemic of neurological diseases. Despite the complex etiology of the disease, an exact cause of itch should be searched for in each patient, as successful therapy is largely dependent on the determination of the cause of the itching. PMID:27578067

  3. SOPROLIFE System: An Accurate Diagnostic Enhancer

    PubMed Central

    Zeitouny, Mona; Feghali, Mireille; Nasr, Assaad; Abou-Samra, Philippe; Saleh, Nadine; Bourgeois, Denis; Farge, Pierre

    2014-01-01

    Objectives. The aim of this study was to evaluate a light-emitting diode fluorescence tool, the SOPROLIFE light-induced fluorescence evaluator, and compare it to the international caries detection and assessment system-II (ICDAS-II) in the detection of occlusal caries. Methods. A total of 219 permanent posterior teeth in 21 subjects, with age ranging from 15 to 65 years, were examined. An intraclass correlation coefficient (ICC) was computed to assess the reliability between the two diagnostic methods. Results. The results showed a high reliability between the two methods (ICC = 0.92; IC = 0.901–0.940; P < 0.001). The SOPROLIFE blue fluorescence mode had a high sensitivity (87%) and a high specificity (99%) when compared to ICDAS-II. Conclusion. Compared to the most used visual method in the diagnosis of occlusal caries lesions, the finding from this study suggests that SOPROLIFE can be used as a reproducible and reliable assessment tool. At a cut-off point, categorizing noncarious lesions and visual change in enamel, SOPROLIFE shows a high sensitivity and specificity. We can conclude that financially ICDAS is better than SOPROLIFE. However SOPROLIFE is easier for clinicians since it is a simple evaluation of images. Finally in terms of efficiency SOPROLIFE is not superior to ICDAS but tends to be equivalent with the same advantages. PMID:25401161

  4. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as...

  5. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as...

  6. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as...

  7. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as...

  8. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as...

  9. Diagnostic procedures for autoimmune vesiculobullous diseases: A review

    PubMed Central

    Rastogi, Varun; Sharma, Rachna; Misra, Satya Ranjan; Yadav, Lalita

    2014-01-01

    Oral soft tissues are affected by numerous pathologic conditions of variable etiology and hence their appropriate management relies on their accurate diagnosis. Clinical identification of intact vesicle and bulla in the oral cavity is really a challenge due to the regular irritation and the friable nature of oral mucosa. Rupture of these lesions leads to erosions or ulcerations on the surface, hence making the diagnosis of vesiculobullous (VB) lesions is even more difficult due to the fact that the differential diagnosis along with VB lesions will also include ulcerative, immunological-mediated diseases, and neoplasms and systemic diseases. Hence, knowledge of the clinical presentation of these disorders and the relevant diagnostic procedures is important not just for dermatologists, but also for general practitioners and dentists. In this article, the various procedures have been explained that can be used for the diagnostic purpose of VB lesions. PMID:25948994

  10. Diagnostic Procedures and Management of Dry Eye

    PubMed Central

    Kaštelan, Snježana; Tomić, Martina; Salopek-Rabatić, Jasminka; Novak, Branko

    2013-01-01

    Dry eye disease or dysfunctional tear syndrome is among the most frequent diagnoses in ophthalmology. It is a multifactorial disease of the ocular surface and tear film which results in ocular discomfort, visual disturbances, and tear instability with potential damage to the cornea and conjunctiva. Risk factors for dry eye syndrome include age, sex (female gender), race, contact lens wear, environment with low humidity, systemic medications, and autoimmune disorders. The aim of this paper is to present the systematic classification, epidemiology, diagnostic procedures, and advances in the management of dry eye disease. The recent improvements in comprehending the underlying etiologic factors will inevitably improve future classifications and diagnostic abilities leading to more effective therapeutic options. Treatment of this highly prevalent condition can drastically improve the quality of life of individuals and prevent damage to the ocular surface. PMID:24024186

  11. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation...

  12. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true Diagnostic surgical procedures. 220.60 Section... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation...

  13. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation...

  14. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation...

  15. 20 CFR 416.919m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false Diagnostic tests or procedures. 416.919m... for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any diagnostic tests or procedures that have been performed as part of a workup by your treating source or...

  16. 20 CFR 416.919m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 2 2012-04-01 2012-04-01 false Diagnostic tests or procedures. 416.919m... for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any diagnostic tests or procedures that have been performed as part of a workup by your treating source or...

  17. 20 CFR 416.919m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Diagnostic tests or procedures. 416.919m... for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any diagnostic tests or procedures that have been performed as part of a workup by your treating source or...

  18. 20 CFR 220.60 - Diagnostic surgical procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true Diagnostic surgical procedures. 220.60 Section... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation...

  19. 20 CFR 416.919m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 2 2014-04-01 2014-04-01 false Diagnostic tests or procedures. 416.919m... for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any diagnostic tests or procedures that have been performed as part of a workup by your treating source or...

  20. 20 CFR 416.919m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Diagnostic tests or procedures. 416.919m... for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any diagnostic tests or procedures that have been performed as part of a workup by your treating source or...

  1. A general, accurate procedure for calculating molecular interaction force.

    PubMed

    Yang, Pinghai; Qian, Xiaoping

    2009-09-15

    The determination of molecular interaction forces, e.g., van der Waals force, between macroscopic bodies is of fundamental importance for understanding sintering, adhesion and fracture processes. In this paper, we develop an accurate, general procedure for van der Waals force calculation. This approach extends a surface formulation that converts a six-dimensional (6D) volume integral into a 4D surface integral for the force calculation. It uses non-uniform rational B-spline (NURBS) surfaces to represent object surfaces. Surface integrals are then done on the parametric domain of the NURBS surfaces. It has combined advantages of NURBS surface representation and surface formulation, including (1) molecular interactions between arbitrary-shaped objects can be represented and evaluated by the NURBS model further common geometries such as spheres, cones, planes can be represented exactly and interaction forces are thus calculated accurately; (2) calculation efficiency is improved by converting the volume integral to the surface integral. This approach is implemented and validated via its comparison with analytical solutions for simple geometries. Calculation of van der Waals force between complex geometries with surface roughness is also demonstrated. A tutorial on the NURBS approach is given in Appendix A. PMID:19596335

  2. Psychoeducational Diagnostic Services for Learning Disabled Youths. Research Procedures.

    ERIC Educational Resources Information Center

    Barrows, Thomas S.; And Others

    A detailed explicit definition of learning disability (LD) is presented in terms of the diagnostic procedures and decision points used in identifying that category among a group of juvenile delinquent and control group adolescent males. The described procedures include a review of existing records, interviews, and diagnostic assessments.…

  3. Cancer Risks Associated with External Radiation From Diagnostic Imaging Procedures

    PubMed Central

    Linet, Martha S.; Slovis, Thomas L.; Miller, Donald L.; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; de Gonzalez, Amy Berrington

    2012-01-01

    The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate widespread use of evidence-based appropriateness criteria for decisions about imaging procedures, oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives, development of electronic lifetime records of imaging procedures for patients and their physicians, and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures. PMID:22307864

  4. Diagnostic anterior chamber paracentesis in uveitis: a safe procedure?

    PubMed Central

    Van der Lelij, A.; Rothova, A.

    1997-01-01

    BACKGROUND—Differentiation between infectious and non-infectious uveitis is of crucial value for accurate management of patients with uveitis. Tests performed on aqueous humour yield more relevant information than those done in serum. The objective of this study was to evaluate whether the aqueous humour tap for diagnostic purposes is a safe procedure to perform in uveitis patients.
METHODS—In this retrospective study 361 patients with uveitis, who underwent a diagnostic anterior chamber paracentesis in an outpatient clinic, were investigated. 72 of the 361 patients were examined 30 minutes after the puncture. The site of the paracentesis, the depth of the anterior chamber, and cells in the anterior chamber were examined. All 361 patients were evaluated within 2 weeks after the paracentesis was performed. The final follow up period varied from 6 months to more than 3 years. The clinical data were analysed with the emphasis on the occurrence of cataract and a history of corneal infections or endophthalmitis.
RESULTS—In this series no serious side effects such as cataract, keratitis, or endophthalmitis were observed. The depth of the anterior chamber of all evaluated patients was restored after 30 minutes. In five out of 72 cases (three AIDS patients with cytomegalovirus retinitis and two patients with anterior uveitis due to herpes simplex virus) a small hyphaema was observed 30 minutes after the paracentesis took place.
CONCLUSION—Anterior chamber paracentesis appears to be a safe procedure in the hands of an experienced ophthalmologist.

 PMID:9505822

  5. Quantitative analysis of noninvasive diagnostic procedures for induction motor drives

    NASA Astrophysics Data System (ADS)

    Eltabach, Mario; Antoni, Jerome; Najjar, Micheline

    2007-10-01

    This paper reports quantitative analyses of spectral fault components in five noninvasive diagnostic procedures that use input electric signals to detect different types of abnormalities in induction motors. Besides the traditional one phase current spectrum analysis "SC", the diagnostic procedures based on spectrum analysis of the instantaneous partial powers " P ab", " P cb", total power " P abc", and the current space vector modulus " csvm" are considered. The aim of this comparison study is to improve the diagnosis tools for detection of electromechanical faults in electrical machines by using the best suitable diagnostic procedure knowing some motor and fault characteristics. Defining a severity factor as the increase in amplitude of the fault characteristic frequency, with respect to the healthy condition, enables us to study the sensitivity of the electrical diagnostic tools. As a result, it is shown that the relationship between the angular displacement of the current side-bands components at frequencies ( f± fosc) is directly related to the type of induction motor faults. It is also proved that the total instantaneous power diagnostic procedure was observed to exhibit the highest values of the detection criterion in case of mechanical faults while in case of electrical ones the most reliable diagnostic procedure is tightly related to the value of the motor power factor angle and the group motor-load inertia. Finally, simulation and experimental results show good agreement with the fault modeling theoretical results.

  6. Reduction procedures for accurate analysis of MSX surveillance experiment data

    NASA Technical Reports Server (NTRS)

    Gaposchkin, E. Mike; Lane, Mark T.; Abbot, Rick I.

    1994-01-01

    Technical challenges of the Midcourse Space Experiment (MSX) science instruments require careful characterization and calibration of these sensors for analysis of surveillance experiment data. Procedures for reduction of Resident Space Object (RSO) detections will be presented which include refinement and calibration of the metric and radiometric (and photometric) data and calculation of a precise MSX ephemeris. Examples will be given which support the reduction, and these are taken from ground-test data similar in characteristics to the MSX sensors and from the IRAS satellite RSO detections. Examples to demonstrate the calculation of a precise ephemeris will be provided from satellites in similar orbits which are equipped with S-band transponders.

  7. Knowledge of accurate blood pressure measurement procedures in chiropractic students

    PubMed Central

    Crosley, Angela M.; Rose, James R. La

    2013-01-01

    Objective Blood pressure measurement is a basic clinical procedure. However, studies have shown that many errors are made when health care providers acquire blood pressure readings. Our study assessed knowledge of blood pressure measurement procedures in chiropractic students. Methods This was an observational, descriptive study. A questionnaire based on one created by the American Heart Association was given to 1st, 2nd, 3rd, and final year students (n = 186). A one way ANOVA was used to analyze the data. Results Of the students 80% were confident that their knowledge of this clinical skill was adequate or better. However, the overall score on the knowledge test of blood pressure–taking skills was 52% (range, 24%–88%). The only significant difference in the mean scores was between the 1st and 2nd year students compared to the 3rd and 4th year students (p < .005). Of the 16 questions given, the following mean scores were: 1st year 10.45, 2nd year 9.75, 3rd year 7.93, and 4th year 8.33. Of the 16 areas tested, 10 were of major concern (test item score <70%), showing the need for frequent retraining of chiropractic students. Conclusion Consistent with studies in other health care disciplines, our research found the knowledge of blood pressure skills to be deficient in our sample. There is a need for subsequent training in our teaching program. PMID:23957320

  8. Diagnostic oral food challenges: procedures and biomarkers.

    PubMed

    Järvinen, Kirsi M; Sicherer, Scott H

    2012-09-28

    Oral food challenge (OFC) is the gold standard for the diagnosis of food allergy. They are conducted to confirm whether an allergy to food exists (initial challenge) or to monitor for resolution of a food allergy. The history of an immediate allergic reaction, when supported by positive tests for specific IgE antibodies to the suspect food, is often sufficient to establish a diagnosis without OFC. Additionally, higher concentrations of food-specific IgE or larger allergy prick skin test wheal sizes correlate with an increased likelihood of a reaction upon ingestion. Although these food-specific IgE tests are helpful biomarkers of allergy, their limited sensitivity and specificity often necessitates the use of OFC to establish reactivity. Furthermore, the pathogenesis of non-IgE-mediated food allergy, such as food protein-induced enterocolitis (FPIES) or proctocolitis and food allergy due to mixed IgE and non-IgE mediated processes, such as atopic dermatitis or eosinophilic gastroenteropathies may not be assessable with specific IgE tests, also warranting OFCs. This review provides an overview on the technique and interpretation of OFCs, use of food-specific testing to predict whether OFC is warranted and to predict OFC outcomes. Additionally, biomarkers that correlate with OFC outcomes will be discussed, as well as future diagnostic tests promising better predictive value. PMID:22414488

  9. Diagnostic procedures for submucosal tumors in the gastrointestinal tract

    PubMed Central

    Ponsaing, Laura Graves; Kiss, Katalin; Loft, Annika; Jensen, Lise Ingemann; Hansen, Mark Berner

    2007-01-01

    This review is part one of three, which will present an update on diagnostic procedures for gastrointestinal (GI) submucosal tumors (SMTs). Part two identifies the classification and part three the therapeutic methods regarding GI SMTs. Submucosal tumors are typically asymptomatic and therefore encountered incidentally. Advances in diagnostic tools for gastrointestinal submucosal tumors have emerged over the past decade. The aim of this paper is to provide the readers with guidelines for the use of diagnostic procedures, when a submucosal tumor is suspected. Literature searches were performed to find information on diagnostics for gastrointestinal submucosal tumors. Based on the searches, the optimal diagnostic procedures and specific features of the submucosal tumors could be outlined. Standard endoscppy, capsule endoscopy and push-and-pull enteroscopy (PPE) together with barium contrast X-ray do not alone provide sufficient information, when examining submucosal tumors. Endoscopic ultrasound (EUS), computed tomography (CT), magnetic resonance imaging (MRI) and fluorodeoxyglucose-labeled positron emission tomography (FDG-PET) are recommended as supplementary tools. PMID:17659668

  10. Diagnostic Procedures for Detecting Nonlinear Relationships between Latent Variables

    ERIC Educational Resources Information Center

    Bauer, Daniel J.; Baldasaro, Ruth E.; Gottfredson, Nisha C.

    2012-01-01

    Structural equation models are commonly used to estimate relationships between latent variables. Almost universally, the fitted models specify that these relationships are linear in form. This assumption is rarely checked empirically, largely for lack of appropriate diagnostic techniques. This article presents and evaluates two procedures that can…

  11. Expert systems should be more accurate than human experts - Evaluation procedures from human judgment and decisionmaking

    NASA Technical Reports Server (NTRS)

    Levi, Keith

    1989-01-01

    Two procedures for the evaluation of the performance of expert systems are illustrated: one procedure evaluates predictive accuracy; the other procedure is complementary in that it uncovers the factors that contribute to predictive accuracy. Using these procedures, it is argued that expert systems should be more accurate than human experts in two senses. One sense is that expert systems must be more accurate to be cost-effective. Previous research is reviewed and original results are presented which show that simple statistical models typically perform better than human experts for the task of combining evidence from a given set of information sources. The results also suggest the second sense in which expert systems should be more accurate than human experts. They reveal that expert systems should share factors that contribute to human accuracy, but not factors that detract from human accuracy. Thus the thesis is that one should both require and expect systems to be more accurate than humans.

  12. [Pediatric patient sedation and analgesia for diagnostic medical procedures].

    PubMed

    Kadosaki, Mamoru

    2014-08-01

    There is an increasing demand for anesthesiologists to work outside the operating room in order to provide general anesthesia or monitored sedation for a variety of medical investigations or procedures in infants and children. The concept that treatment should be a pain- and stress-free experience is now well accepted, and this has placed additional responsibilities on anesthesiologists. We describe pediatric anesthesia and monitored sedation for diagnostic medical procedures. Children requiring a painful procedure and prolonged examination should be provided with optimal sedation and analgesia. The child should be monitored with standard ASA monitors. In the case of medical procedures such as gastrointestinal endoscopy, transesophageal echocardiography, and cardiac catheterization, general endotracheal anesthesia with neuromuscular block is recommended. Several short-acting anesthetic drugs, including sevoflurane, propofol, remifentanil, and rocuronium, have become available in Japan, and the safety and efficacy of pediatric general anesthesia for diagnostic medical procedures have improved. Infants who require a noninvasive and short examination may not be provided with anesthetics. The feed and wrap method is recommended. Satisfactory immobilization of the child during noninvasive medical procedures, including magnetic resonance imaging, may be achieved by intravenous sedation or general anesthesia. Monitored intravenous sedation using propofol is the most widely used for healthy children; general anesthesia with a laryngeal mask airway or endotracheal intubation and controlled ventilation is required for a critically ill child. PMID:25669029

  13. Diagnostic methodology is critical for accurately determining the prevalence of ichthyophonus infections in wild fish populations

    USGS Publications Warehouse

    Kocan, R.; Dolan, H.; Hershberger, P.

    2011-01-01

    Several different techniques have been employed to detect and identify Ichthyophonus spp. in infected fish hosts; these include macroscopic observation, microscopic examination of tissue squashes, histological evaluation, in vitro culture, and molecular techniques. Examination of the peer-reviewed literature revealed that when more than 1 diagnostic method is used, they often result in significantly different results; for example, when in vitro culture was used to identify infected trout in an experimentally exposed population, 98.7% of infected trout were detected, but when standard histology was used to confirm known infected tissues from wild salmon, it detected ~50% of low-intensity infections and ~85% of high-intensity infections. Other studies on different species reported similar differences. When we examined a possible mechanism to explain the disparity between different diagnostic techniques, we observed non-random distribution of the parasite in 3-dimensionally visualized tissue sections from infected hosts, thus providing a possible explanation for the different sensitivities of commonly used diagnostic techniques. Based on experimental evidence and a review of the peer-reviewed literature, we have concluded that in vitro culture is currently the most accurate diagnostic technique for determining infection prevalence of Ichthyophonus, particularly when the exposure history of the population is not known.

  14. Diagnostic methodology is critical for accurately determining the prevalence of Ichthyophonus infections in wild fish populations.

    PubMed

    Kocan, Richard; Dolan, Heather; Hershberger, Paul

    2011-04-01

    Several different techniques have been employed to detect and identify Ichthyophonus spp. in infected fish hosts; these include macroscopic observation, microscopic examination of tissue squashes, histological evaluation, in vitro culture, and molecular techniques. Examination of the peer-reviewed literature revealed that when more than 1 diagnostic method is used, they often result in significantly different results; for example, when in vitro culture was used to identify infected trout in an experimentally exposed population, 98.7% of infected trout were detected, but when standard histology was used to confirm known infected tissues from wild salmon, it detected ~50% of low-intensity infections and ~85% of high-intensity infections. Other studies on different species reported similar differences. When we examined a possible mechanism to explain the disparity between different diagnostic techniques, we observed non-random distribution of the parasite in 3-dimensionally visualized tissue sections from infected hosts, thus providing a possible explanation for the different sensitivities of commonly used diagnostic techniques. Based on experimental evidence and a review of the peer-reviewed literature, we have concluded that in vitro culture is currently the most accurate diagnostic technique for determining infection prevalence of Ichthyophonus , particularly when the exposure history of the population is not known. PMID:21506773

  15. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and other diagnostic procedures. 413.122 Section 413.122 Public Health CENTERS FOR MEDICARE & MEDICAID... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements... services and other diagnostic procedures performed by a hospital on an outpatient basis. (2) For...

  16. Using Copula Distributions to Support More Accurate Imaging-Based Diagnostic Classifiers for Neuropsychiatric Disorders

    PubMed Central

    Bansal, Ravi; Hao, Xuejun; Liu, Jun; Peterson, Bradley S.

    2014-01-01

    Many investigators have tried to apply machine learning techniques to magnetic resonance images (MRIs) of the brain in order to diagnose neuropsychiatric disorders. Usually the number of brain imaging measures (such as measures of cortical thickness and measures of local surface morphology) derived from the MRIs (i.e., their dimensionality) has been large (e.g. >10) relative to the number of participants who provide the MRI data (<100). Sparse data in a high dimensional space increases the variability of the classification rules that machine learning algorithms generate, thereby limiting the validity, reproducibility, and generalizability of those classifiers. The accuracy and stability of the classifiers can improve significantly if the multivariate distributions of the imaging measures can be estimated accurately. To accurately estimate the multivariate distributions using sparse data, we propose to estimate first the univariate distributions of imaging data and then combine them using a Copula to generate more accurate estimates of their multivariate distributions. We then sample the estimated Copula distributions to generate dense sets of imaging measures and use those measures to train classifiers. We hypothesize that the dense sets of brain imaging measures will generate classifiers that are stable to variations in brain imaging measures, thereby improving the reproducibility, validity, and generalizability of diagnostic classification algorithms in imaging datasets from clinical populations. In our experiments, we used both computer-generated and real-world brain imaging datasets to assess the accuracy of multivariate Copula distributions in estimating the corresponding multivariate distributions of real-world imaging data. Our experiments showed that diagnostic classifiers generated using imaging measures sampled from the Copula were significantly more accurate and more reproducible than were the classifiers generated using either the real-world imaging

  17. Ascitic Fluid Calprotectin and Serum Procalcitonin as Accurate Diagnostic Markers for Spontaneous Bacterial Peritonitis

    PubMed Central

    Abdel-Razik, Ahmed; Mousa, Nasser; Elhammady, Dina; Elhelaly, Rania; Elzehery, Rasha; Elbaz, Sherif; Eissa, Mohamed; El-Wakeel, Niveen; Eldars, Waleed

    2016-01-01

    Background/Aims The diagnosis of spontaneous bacterial peritonitis (SBP) is based on a polymorphonuclear leukocytes (PMNs) exceeding 250/μL in ascitic fluid. The aim of the study was to evaluate serum procalcitonin and ascitic fluid calprotectin as accurate diagnostic markers for detecting SBP. Methods Seventy-nine patients with cirrhotic ascites were included. They were divided into a SBP group, including 52 patients, and a non-SBP group of 27 patients. Serum procalcitonin, ascitic calprotectin, and serum and ascitic levels of tumor necrosis factor α (TNF-α) and interleukin 6 (IL-6) were measured using an enzyme-linked immunosorbent assay. Results Serum procalcitonin and ascitic calprotectin were significantly higher in SBP patients than in non-SBP patients. Significant increases in both serum and ascitic levels of TNF-α and IL-6 were observed in SBP patients versus non-SBP patients. At a cutoff value of 0.94 ng/mL, serum procalcitonin had 94.3% sensitivity and 91.8% specificity for detecting SBP. In addition, at a cutoff value of 445 ng/mL, ascitic calprotectin had 95.4% sensitivity and 85.2% specificity for detecting SBP. Both were positively correlated with ascitic fluid proteins, PMN count, TNF-α, and IL-6. Conclusions According to our findings, determination of serum procalcitonin levels and ascitic calprotectin appears to provide satisfactory diagnostic markers for the diagnosis of SBP. PMID:26601826

  18. Latest advances in advanced diagnostic and therapeutic pulmonary procedures.

    PubMed

    Silvestri, Gerard A; Feller-Kopman, David; Chen, Alexander; Wahidi, Momen; Yasufuku, Kazuhiro; Ernst, Armin

    2012-12-01

    Over the past 15 years, patients with a myriad of pulmonary conditions have been diagnosed and treated with new technologies developed for the pulmonary community. Advanced diagnostic and therapeutic procedures once performed in an operating theater under general anesthesia are now routinely performed in a bronchoscopy suite under moderate sedation with clinically meaningful improvements in outcome. With the miniaturization of scopes and instruments, improvements in optics, and creative engineers, a host of new devices has become available for clinical testing and use. A growing community of pulmonologists is doing comparative effectiveness trials that test new technologies against the current standard of care. While more research is needed, it seems reasonable to provide an overview of pulmonary procedures that are in various stages of development, testing, and practice at this time. Five areas are covered: navigational bronchoscopy, endobronchial ultrasound, endoscopic lung volume reduction, bronchial thermoplasty, and pleural procedure. Appropriate training for clinicians who wish to provide these services will become an area of intense scrutiny as new skills will need to be acquired to ensure patient safety and a good clinical result. PMID:23208336

  19. Introducing GAMER: A fast and accurate method for ray-tracing galaxies using procedural noise

    SciTech Connect

    Groeneboom, N. E.; Dahle, H.

    2014-03-10

    We developed a novel approach for fast and accurate ray-tracing of galaxies using procedural noise fields. Our method allows for efficient and realistic rendering of synthetic galaxy morphologies, where individual components such as the bulge, disk, stars, and dust can be synthesized in different wavelengths. These components follow empirically motivated overall intensity profiles but contain an additional procedural noise component that gives rise to complex natural patterns that mimic interstellar dust and star-forming regions. These patterns produce more realistic-looking galaxy images than using analytical expressions alone. The method is fully parallelized and creates accurate high- and low- resolution images that can be used, for example, in codes simulating strong and weak gravitational lensing. In addition to having a user-friendly graphical user interface, the C++ software package GAMER is easy to implement into an existing code.

  20. Mediastinoscopy: a diagnostic procedure in hilar and paratracheal lymphadenopathy

    PubMed Central

    Mikhail, J. R.; Mitchell, D. N.

    1971-01-01

    Mediastinoscopy, in the skilled hands of a thoracic surgeon, is a safe, cosmetically accepted procedure with negligible complications, less than that reported in many series of scalene node biopsies. It has the advantage of yielding a much higher rate of diagnostic tissue, in all instances over 90%. In the cases of tuberculosis it enabled an organism to be isolated and sensitivities obtained. It has also revealed a group of cases with findings, a further study of which may increase our understanding, assessment and management of patients presenting with hilar and/or paratracheal lymphadenopathy. ImagesFig. 1Fig. 2Figs. 3-6Figs. 7-10Fig. 11Fig. 12Figs. 13 and 14Fig. 15Fig. 16Fig. 17Fig. 18Fig. 19Fig. 20 PMID:4110536

  1. 78 FR 20103 - Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... AGENCY Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures AGENCY..., on Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures. This document is... for Diagnostic X-rays,'' which was released in October 1976. The recommendations contained in...

  2. Neonatal Cholestasis – Differential Diagnoses, Current Diagnostic Procedures, and Treatment

    PubMed Central

    Götze, Thomas; Blessing, Holger; Grillhösl, Christian; Gerner, Patrick; Hoerning, André

    2015-01-01

    Cholestatic jaundice in early infancy is a complex diagnostic problem. Misdiagnosis of cholestasis as physiologic jaundice delays the identification of severe liver diseases. In the majority of infants, prolonged physiologic jaundice represent benign cases of breast milk jaundice, but few among them are masked and caused by neonatal cholestasis (NC) that requires a prompt diagnosis and treatment. Therefore, a prolonged neonatal jaundice, longer than 2 weeks after birth, must always be investigated because an early diagnosis is essential for appropriate management. To rapidly identify the cases with cholestatic jaundice, the conjugated bilirubin needs to be determined in any infant presenting with prolonged jaundice at 14 days of age with or without depigmented stool. Once NC is confirmed, a systematic approach is the key to reliably achieve the diagnosis in order to promptly initiate the specific, and in many cases, life-saving therapy. This strategy is most important to promptly identify and treat infants with biliary atresia, the most common cause of NC, as this requires a hepatoportoenterostomy as soon as possible. Here, we provide a detailed work-up approach including initial treatment recommendations and a clinically oriented overview of possible differential diagnoses in order to facilitate the early recognition and a timely diagnosis of cholestasis. This approach warrants a broad spectrum of diagnostic procedures and investigations including new methods that are described in this review. PMID:26137452

  3. Procedure for accurate fabrication of tissue compensators with high-density material

    NASA Astrophysics Data System (ADS)

    Mejaddem, Younes; Lax, Ingmar; Adakkai K, Shamsuddin

    1997-02-01

    An accurate method for producing compensating filters using high-density material (Cerrobend) is described. The procedure consists of two cutting steps in a Styrofoam block: (i) levelling a surface of the block to a reference level; (ii) depth-modulated milling of the levelled block in accordance with pre-calculated thickness profiles of the compensator. The calculated thickness (generated by a dose planning system) can be reproduced within acceptable accuracy. The desired compensator thickness manufactured according to this procedure is reproduced to within 0.1 mm, corresponding to a 0.5% change in dose at a beam quality of 6 MV. The results of our quality control checks performed with the technique of stylus profiling measurements show an accuracy of 0.04 mm in the milling process over an arbitrary profile along the milled-out Styrofoam block.

  4. Lateral force calibration: accurate procedures for colloidal probe friction measurements in atomic force microscopy.

    PubMed

    Chung, Koo-Hyun; Pratt, Jon R; Reitsma, Mark G

    2010-01-19

    The colloidal probe technique for atomic force microscopy (AFM) has allowed the investigation of an extensive range of surface force phenomena, including the measurement of frictional (lateral) forces between numerous materials. The quantitative accuracy of such friction measurements is often debated, in part due to a lack of confidence in existing calibration strategies. Here we compare three in situ AFM lateral force calibration techniques using a single colloidal probe, seeking to establish a foundation for quantitative measurement by linking these techniques to accurate force references available at the National Institute of Standards and Technology. We introduce a procedure for calibrating the AFM lateral force response to known electrostatic forces applied directly to the conductive colloidal probe. In a second procedure, we apply known force directly to the colloidal probe using a precalibrated piezo-resistive reference cantilever. We found agreement between these direct methods on the order of 2% (within random uncertainty for both measurements). In a third procedure, we performed a displacement-based calibration using the piezo-resistive reference cantilever as a stiffness reference artifact. The method demonstrated agreement on the order of 7% with the direct force methods, with the difference attributed to an expected systematic uncertainty, caused by in-plane deflection in the cantilever during loading. The comparison establishes the existing limits of instrument accuracy and sets down a basis for selection criteria for materials and methods in colloidal probe friction (lateral) force measurements via atomic force microscopy. PMID:19827782

  5. [List of diagnostic tests and procedures in leg ulcer].

    PubMed

    Spoljar, Sanja

    2013-10-01

    Many factors contribute to the pathogenesis of leg ulcer. Most patients have venous leg ulcer due to chronic venous insufficiency. Less often, patients have arterial leg ulcer resulting from peripheral arterial occlusive disease, the most common cause of which is arteriosclerosis. Leg ulcer may be of a mixed arteriovenous origin. In diabetic patients, distal symmetric neuropathy and peripheral vascular disease are probably the most important etiologic factors in the development of diabetic leg ulcer. Other causes of chronic leg ulcers are hematologic diseases, autoimmune diseases, genetic defects, infectious diseases, primary skin diseases, cutaneous malignant diseases, use of some medications and therapeutic procedures, and numerous exogenous factors. Diagnosis of leg ulcer is based on medical history, inspection, palpation of skin temperature, palpation of arteries, fascia holes, presence and degree of edema, firm painful cords, and functional testing to assess peripheral occlusive arterial disease or identify superficial and deep venous reflux of the legs. Knowledge of differential diagnosis is essential for ensuring treatment success in patients with leg ulcer. There are many possible etiologic factors of leg ulcers and sometimes, clinical findings are similar. Additional testing should be performed, e.g., serologic testing such as blood count, C-reactive protein, HBA1c, erythrocyte sedimentation rate, differential blood count, total proteins, electrolytes, coagulation parameters, circulating immune complex, cryoglobulins, homocysteins, AT, PAI-1, APC resistance, proteins C and S, paraproteins, ANA, ENA, ANCA, dsDNA, antiphospholipid antibodies, urea, creatinine, blood lipids, vitamins and trace elements. Also, biopsy of the lesion for histopathology, direct immunofluorescence, bacteriology and mycology should be included. Other tests are Raynaud (cold stimulation) test and pathergy test. Device-based diagnostic testing should be performed for future

  6. A Complete Molecular Diagnostic Procedure for Applications in Surveillance and Subtyping of Avian Influenza Virus

    PubMed Central

    Tseng, Chun-Hsien; Tsai, Hsiang-Jung; Chang, Chung-Ming

    2014-01-01

    Introduction. The following complete molecular diagnostic procedure we developed, based on real-time quantitative PCR and traditional PCR, is effective for avian influenza surveillance, virus subtyping, and viral genome sequencing. Method. This study provides a specific and sensitive step-by-step procedure for efficient avian influenza identification of 16 hemagglutinin and 9 neuraminidase avian influenza subtypes. Result and Conclusion. This diagnostic procedure may prove exceedingly useful for virological and ecological advancements in global avian influenza research. PMID:25057497

  7. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Procedures for preparing egg yolk... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... chapter. (a) Under the supervision of an Authorized Agent or State Inspector, the eggs which are used...

  8. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Procedures for preparing egg yolk... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... chapter. (a) Under the supervision of an Authorized Agent or State Inspector, the eggs which are used...

  9. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Procedures for preparing egg yolk... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... chapter. (a) Under the supervision of an Authorized Agent or State Inspector, the eggs which are used...

  10. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    PubMed Central

    Rogers, Linda C.; Scott, Laurie; Block, Jon E.

    2016-01-01

    OBJECTIVE Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. METHODS Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus®) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. RESULTS Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%), specificity (94.8% vs. 79.3%), PPV (75% vs. 36.8%), NPV (100% vs. 95.8%), and accuracy (95.5% vs. 79.1%). CONCLUSIONS The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity. PMID:27199579

  11. Development of a Sampling Collection Device with Diagnostic Procedures.

    PubMed

    Cheng, Jhih-Yan; Feng, Mow-Jung; Wu, Chia-Chi; Wang, Jane; Chang, Ting-Chang; Cheng, Chao-Min

    2016-08-01

    Cervicovaginal fluid plays an important role in the detection of many female genital diseases, but the lack of suitable collection devices in the market severely challenges test success rate. Appropriate clinical sampling devices for cervicovaginal fluid collection would help physicians detect diseases and disease states more rapidly, efficiently, and accurately. The objective of this study was to develop a readily usable sampling collection device that would eliminate macromolecular interference and accurately provide specimens for further studies. This study was designed to develop an effective device to collect cervicovaginal fluid from women with symptoms of endometrial lesions, women appearing in the clinic for a routine Papanicolaou smear, and/or women seeking a routine gynecologic checkup. Paper-based assay, ELISA, and qNano were used to provide accurate diagnoses. A total of 103 patients successfully used the developed device to collect cervicovaginal fluid. Some of the collected specimens were used to detect glycogen, lactate, and pH for determining pathogen infection. Other specimen samples were tested for the presence of female genital cancer by comparing interleukin 6 concentration and microvesicle concentration. We proposed a noninvasive screening test for the diagnosis of female genital diseases using a dual-material collection device. The outer, nonwoven fabric portion of this device was designed to filter macromolecules, and the inner cotton portion was designed to absorb cervicovaginal fluid. PMID:27338148

  12. 45 CFR 261.64 - How will we determine whether a State's work verification procedures ensure an accurate work...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 2 2014-10-01 2012-10-01 true How will we determine whether a State's work verification procedures ensure an accurate work participation measurement? 261.64 Section 261.64 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES,...

  13. 45 CFR 261.64 - How will we determine whether a State's work verification procedures ensure an accurate work...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false How will we determine whether a State's work verification procedures ensure an accurate work participation measurement? 261.64 Section 261.64 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES,...

  14. Diagnostic medicine: A comprehensive ABCDE algorithm for accurate interpretation of radiology and pathology images and data.

    PubMed

    Zioga, Christina A; Destouni, Chariklia T

    2015-01-01

    A pathway to the procedure of interpreting radiology images or pathology slides is presented. This simplified mnemonic can be used as a memory aid determining the order in which diagnosis should be approached. First, before we place the radiology image in front of the lightbox or the slide under the microscope we have to be sure that it is adequately labelled and prepared (Correct). It is also necessary to have or gather all available information concerning the patient and if possible his full medical history (A, Available Information). Once we come across the image, two fundamental questions should be answered: which part of the body does the image concern and-where applicable-if the image is adequate (B, Body). Next, we proceed to answer if we have a neoplastic tissue or not (C, Cancer). We then either form a differential diagnosis list or we reach to a final diagnosis (D, Diagnosis), which is followed by the writing of the report (E, Exhibit). These series of steps followed as an ad hoc procedure by most specialists, are important in order to achieve a complete and clear diagnosis and report, which is intended to support optimal clinical practice. This ABCDE concept is a generic standard approach which is not limited to specific specimens and can lead to faster diagnosis with less mistakes. PMID:26665217

  15. RT-PCR is a more accurate diagnostic tool for detection of BCR-ABL rearrangement

    SciTech Connect

    Zehnbauer, B.A.; Allen, A.P.; McGrath, S.D.

    1994-09-01

    Detection of the Philadelphia chromosome (Ph1) or genomic Southern hybridization for clonal gene rearrangement (GSH-R) has provided very specific identification of BCR-ABL gene rearrangement. Reverse transcriptase-polymerase chain reaction (RT-PCR) is diagnostic for patterns of BCR-ABL expression which are undetected by GSH-R and/or Ph1 and provides increased sensitivity both at diagnosis and in detection of minimal residual leukemia. Fifty-three specimens (of 150 tested from 119 consecutive leukemia patients) were RT-PCR positive for BCR-ABL gene expression confirmed by hybridization of PCR products with b{sub 3}a{sub 2}, b{sub 2}a{sub 2}, or e{sub 1}a{sub 2} junction-specific oligonucleotides. In 6 cases of CML with GSH-R{sup {minus}}at diagnosis, RT-PCR provided specific BCR-ABL identification. Deletion of BCR regions, low mitotic index, or e{sub 1}a{sub 2} expression caused failure to detect GSH-R or Ph1 translocation.

  16. Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation

    PubMed Central

    Dingari, Narahara Chari; Horowitz, Gary L.; Kang, Jeon Woong; Dasari, Ramachandra R.; Barman, Ishan

    2012-01-01

    We present the first demonstration of glycated albumin detection and quantification using Raman spectroscopy without the addition of reagents. Glycated albumin is an important marker for monitoring the long-term glycemic history of diabetics, especially as its concentrations, in contrast to glycated hemoglobin levels, are unaffected by changes in erythrocyte life times. Clinically, glycated albumin concentrations show a strong correlation with the development of serious diabetes complications including nephropathy and retinopathy. In this article, we propose and evaluate the efficacy of Raman spectroscopy for determination of this important analyte. By utilizing the pre-concentration obtained through drop-coating deposition, we show that glycation of albumin leads to subtle, but consistent, changes in vibrational features, which with the help of multivariate classification techniques can be used to discriminate glycated albumin from the unglycated variant with 100% accuracy. Moreover, we demonstrate that the calibration model developed on the glycated albumin spectral dataset shows high predictive power, even at substantially lower concentrations than those typically encountered in clinical practice. In fact, the limit of detection for glycated albumin measurements is calculated to be approximately four times lower than its minimum physiological concentration. Importantly, in relation to the existing detection methods for glycated albumin, the proposed method is also completely reagent-free, requires barely any sample preparation and has the potential for simultaneous determination of glycated hemoglobin levels as well. Given these key advantages, we believe that the proposed approach can provide a uniquely powerful tool for quantification of glycation status of proteins in biopharmaceutical development as well as for glycemic marker determination in routine clinical diagnostics in the future. PMID:22393405

  17. Diagnostic x-ray procedures and risk of leukemia, lymphoma, and multiple myeloma

    SciTech Connect

    Boice, J.D. Jr.; Morin, M.M.; Glass, A.G.; Friedman, G.D.; Stovall, M.; Hoover, R.N.; Fraumeni, J.F. Jr. )

    1991-03-13

    Exposure to diagnostic x-rays and the risk of leukemia, non-Hodgkin's lymphoma (NHL), and multiple myeloma were studied within two prepaid health plans. Adult patients with leukemia (n = 565), NHL (n = 318), and multiple myeloma (n = 208) were matched to controls (n = 1390), and over 25,000 x-ray procedures were abstracted from medical records. Dose response was evaluated by assigning each x-ray procedure a score based on estimated bone marrow dose. X-ray exposure was not associated with chronic lymphocytic leukemia, one of the few malignant conditions never linked to radiation (relative risk (RR), 0.66). For all other forms of leukemia combined (n = 358), there was a slight elevation in risk (RR, 1.17) but no evidence of a dose-response relationship when x-ray procedures near the time of diagnosis were excluded. Similarly, patients with NHL were exposed to diagnostic x-ray procedures more often than controls (RR, 1.32), but the RR fell to 0.99 when the exposure to diagnostic x-ray procedures within 2 years of diagnosis was ignored. For multiple myeloma, overall risk was not significantly high (RR, 1.14), but there was consistent evidence of increasing risk with increasing numbers of diagnostic x-ray procedures. These data suggest that persons with leukemia and NHL undergo x-ray procedures frequently just prior to diagnosis for conditions related to the development or natural history of their disease. There was little evidence that diagnostic x-ray procedures were causally associated with leukemia or NHL. The risk for multiple myeloma, however, was increased among those patients who were frequently exposed to x-rays.

  18. Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.

    PubMed

    Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal

    2016-01-01

    The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. PMID:27107691

  19. PROCEDURES FOR ACCURATE PRODUCTION OF COLOR IMAGES FROM SATELLITE OR AIRCRAFT MULTISPECTRAL DIGITAL DATA.

    USGS Publications Warehouse

    Duval, Joseph S.

    1985-01-01

    Because the display and interpretation of satellite and aircraft remote-sensing data make extensive use of color film products, accurate reproduction of the color images is important. To achieve accurate color reproduction, the exposure and chemical processing of the film must be monitored and controlled. By using a combination of sensitometry, densitometry, and transfer functions that control film response curves, all of the different steps in the making of film images can be monitored and controlled. Because a sensitometer produces a calibrated exposure, the resulting step wedge can be used to monitor the chemical processing of the film. Step wedges put on film by image recording machines provide a means of monitoring the film exposure and color balance of the machines.

  20. Accurate, Fast and Cost-Effective Diagnostic Test for Monosomy 1p36 Using Real-Time Quantitative PCR

    PubMed Central

    Cunha, Pricila da Silva; Pena, Heloisa B.; D'Angelo, Carla Sustek; Koiffmann, Celia P.; Rosenfeld, Jill A.; Shaffer, Lisa G.; Stofanko, Martin; Gonçalves-Dornelas, Higgor; Pena, Sérgio Danilo Junho

    2014-01-01

    Monosomy 1p36 is considered the most common subtelomeric deletion syndrome in humans and it accounts for 0.5–0.7% of all the cases of idiopathic intellectual disability. The molecular diagnosis is often made by microarray-based comparative genomic hybridization (aCGH), which has the drawback of being a high-cost technique. However, patients with classic monosomy 1p36 share some typical clinical characteristics that, together with its common prevalence, justify the development of a less expensive, targeted diagnostic method. In this study, we developed a simple, rapid, and inexpensive real-time quantitative PCR (qPCR) assay for targeted diagnosis of monosomy 1p36, easily accessible for low-budget laboratories in developing countries. For this, we have chosen two target genes which are deleted in the majority of patients with monosomy 1p36: PRKCZ and SKI. In total, 39 patients previously diagnosed with monosomy 1p36 by aCGH, fluorescent in situ hybridization (FISH), and/or multiplex ligation-dependent probe amplification (MLPA) all tested positive on our qPCR assay. By simultaneously using these two genes we have been able to detect 1p36 deletions with 100% sensitivity and 100% specificity. We conclude that qPCR of PRKCZ and SKI is a fast and accurate diagnostic test for monosomy 1p36, costing less than 10 US dollars in reagent costs. PMID:24839341

  1. Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study

    PubMed Central

    Ihn, Yon Kwon; Byun, Jun Soo; Suh, Sang Hyun; Won, Yoo Dong; Lee, Deok Hee; Kim, Byung Moon; Kim, Young Soo; Jeon, Pyong; Ryu, Chang-Woo; Suh, Sang-il; Choi, Dae Seob; Choi, See Sung; Choi, Jin Wook; Chang, Hyuk Won; Lee, Jae-Wook; Kim, Sang Heum; Lee, Young Jun; Shin, Shang Hun; Lim, Soo Mee; Yoon, Woong; Jeong, Hae Woong; Han, Moon Hee

    2016-01-01

    Purpose To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). Materials and Methods We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. Results Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm2, 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm2, 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm2 for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm2 for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. Conclusion Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures. PMID:27621943

  2. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE LIVESTOCK IMPROVEMENT AUXILIARY PROVISIONS ON NATIONAL...

  3. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE LIVESTOCK IMPROVEMENT AUXILIARY PROVISIONS ON NATIONAL...

  4. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for...

  5. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for...

  6. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for...

  7. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for...

  8. Procedures for accurate U and Th isotope measurements by high precision MC-ICPMS

    NASA Astrophysics Data System (ADS)

    Hoffmann, Dirk L.; Prytulak, Julie; Richards, David A.; Elliott, Tim; Coath, Christopher D.; Smart, Peter L.; Scholz, Denis

    2007-07-01

    We present multi-collector (MC) inductively coupled plasma mass spectrometry (ICPMS) protocols developed to obtain high precision, accurate determinations of U and Th isotope ratios that are applicable to a wide range of geological materials. MC-ICPMS provides a means to make high precision measurements but a recent laboratory inter-comparison, Regular European Inter-laboratory Measurement Evaluation Programme (REIMEP)-18, indicates that accurate results for U isotope ratios are not currently achieved by all facilities using MC-ICPMS. We detail a suite of protocols that can be used for a wide variety of U and Th isotope ratios and total loads. Particular attention is devoted to instrument optimisation, instrumental backgrounds, stability and memory effects, multiplier nonlinearity and yield determinations. Our results indicate that the extent of mass fractionation of U and Th analyses run under similar instrumental conditions is 0.48% per amu and 0.45% per amu, respectively, but cannot be distinguished at per mil precision levels. However, we note that multiplier-Faraday cup gain can be significantly different for U and Th by 1% and thus a U standard should not be used to correct Th measurements. For this reason, a combination of thermal ionisation mass spectrometry (TIMS) and MC-ICPMS methods have been used to determine the isotopic ratio of an in-house Th standard (TEDDi). As part of our methods, TEDDi and the U standard NBL-112a are used as bracketing standards for Th and U samples, respectively. While the in-house Th standard has 229Th-230Th-232Th composition specific for bracketing low 232Th analyses, the methods have been also successful for silicates with 230Th/232Th <10-5. Using NBL-112a, TEDDi and a gravimetrically calibrated mixed 229Th-236U spike, we demonstrate secular equilibrium in natural materials such as Table Mountain Latite and a Long Valley Glass Mountain sample with a reproducibility of ±3.8 per mil for 230Th/238U and ±2.8 per mil for 234U

  9. A Procedure for Accurately Measuring the Shaker Overturning Moment During Random Vibration Tests

    NASA Technical Reports Server (NTRS)

    Nayeri, Reza D.

    2011-01-01

    Motivation: For large system level random vibration tests, there may be some concerns about the shaker's capability for the overturning moment. It is the test conductor's responsibility to predict and monitor the overturning moment during random vibration tests. If the predicted moment is close to the shaker's capability, test conductor must measure the instantaneous moment at low levels and extrapolate to higher levels. That data will be used to decide whether it is safe to proceed to the next test level. Challenge: Kistler analog formulation for computing the real-time moment is only applicable to very limited cases in which we have 3 or 4 load cells installed at shaker interface with hardware. Approach: To overcome that limitation, a simple procedure was developed for computing the overturning moment time histories using the measured time histories of the individual load cells.

  10. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory...

  11. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory...

  12. A procedure for computing accurate ab initio quartic force fields: Application to HO2+ and H2O

    NASA Astrophysics Data System (ADS)

    Huang, Xinchuan; Lee, Timothy J.

    2008-07-01

    A procedure for the calculation of molecular quartic force fields (QFFs) is proposed and investigated. The goal is to generate highly accurate ab initio QFFs that include many of the so-called ``small'' effects that are necessary to achieve high accuracy. The small effects investigated in the present study include correlation of the core electrons (core correlation), extrapolation to the one-particle basis set limit, correction for scalar relativistic contributions, correction for higher-order correlation effects, and inclusion of diffuse functions in the one-particle basis set. The procedure is flexible enough to allow for some effects to be computed directly, while others may be added as corrections. A single grid of points is used and is centered about an initial reference geometry that is designed to be as close as possible to the final ab initio equilibrium structure (with all effects included). It is shown that the least-squares fit of the QFF is not compromised by the added corrections, and the balance between elimination of contamination from higher-order force constants while retaining energy differences large enough to yield meaningful quartic force constants is essentially unchanged from the standard procedures we have used for many years. The initial QFF determined from the least-squares fit is transformed to the exact minimum in order to eliminate gradient terms and allow for the use of second-order perturbation theory for evaluation of spectroscopic constants. It is shown that this step has essentially no effect on the quality of the QFF largely because the initial reference structure is, by design, very close to the final ab initio equilibrium structure. The procedure is used to compute an accurate, purely ab initio QFF for the H2O molecule, which is used as a benchmark test case. The procedure is then applied to the ground and first excited electronic states of the HO2+ molecular cation. Fundamental vibrational frequencies and spectroscopic

  13. Accurate optical parameter extraction procedure for broadband near-infrared spectroscopy of brain matter

    PubMed Central

    Najafizadeh, Laleh; Gandjbakhche, Amir H.; Pourrezaei, Kambiz; Daryoush, Afshin

    2013-01-01

    Abstract. Modeling behavior of broadband (30 to 1000 MHz) frequency modulated near-infrared (NIR) photons through a phantom is the basis for accurate extraction of optical absorption and scattering parameters of biological turbid media. Photon dynamics in a phantom are predicted using both analytical and numerical simulation and are related to the measured insertion loss (IL) and insertion phase (IP) for a given geometry based on phantom optical parameters. Accuracy of the extracted optical parameters using finite element method (FEM) simulation is compared to baseline analytical calculations from the diffusion equation (DE) for homogenous brain phantoms. NIR spectroscopy is performed using custom-designed, broadband, free-space optical transmitter (Tx) and receiver (Rx) modules that are developed for photon migration at wavelengths of 680, 780, and 820 nm. Differential detection between two optical Rx locations separated by 0.3 cm is employed to eliminate systemic artifacts associated with interfaces of the optical Tx and Rx with the phantoms. Optical parameter extraction is achieved for four solid phantom samples using the least-square-error method in MATLAB (for DE) and COMSOL (for FEM) simulation by fitting data to measured results over broadband and narrowband frequency modulation. Confidence in numerical modeling of the photonic behavior using FEM has been established here by comparing the transmission mode’s experimental results with the predictions made by DE and FEM for known commercial solid brain phantoms. PMID:23322361

  14. An Overview of Models of Speaking Performance and Its Implications for the Development of Procedural Framework for Diagnostic Speaking Tests

    ERIC Educational Resources Information Center

    Zhao, Zhongbao

    2013-01-01

    This paper aims at developing a procedural framework for the development and validation of diagnostic speaking tests. The researcher reviews the current available models of speaking performance, analyzes the distinctive features and then points out the implications for the development of a procedural framework for diagnostic speaking tests. On…

  15. A Three Dimensional Parallel Time Accurate Turbopump Simulation Procedure Using Overset Grid Systems

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin; Chan, William; Kwak, Dochan

    2001-01-01

    The objective of the current effort is to provide a computational framework for design and analysis of the entire fuel supply system of a liquid rocket engine, including high-fidelity unsteady turbopump flow analysis. This capability is needed to support the design of pump sub-systems for advanced space transportation vehicles that are likely to involve liquid propulsion systems. To date, computational tools for design/analysis of turbopump flows are based on relatively lower fidelity methods. An unsteady, three-dimensional viscous flow analysis tool involving stationary and rotational components for the entire turbopump assembly has not been available for real-world engineering applications. The present effort provides developers with information such as transient flow phenomena at start up, and non-uniform inflows, and will eventually impact on system vibration and structures. In the proposed paper, the progress toward the capability of complete simulation of the turbo-pump for a liquid rocket engine is reported. The Space Shuttle Main Engine (SSME) turbo-pump is used as a test case for evaluation of the hybrid MPI/Open-MP and MLP versions of the INS3D code. CAD to solution auto-scripting capability is being developed for turbopump applications. The relative motion of the grid systems for the rotor-stator interaction was obtained using overset grid techniques. Unsteady computations for the SSME turbo-pump, which contains 114 zones with 34.5 million grid points, are carried out on Origin 3000 systems at NASA Ames Research Center. Results from these time-accurate simulations with moving boundary capability will be presented along with the performance of parallel versions of the code.

  16. A Three-Dimensional Parallel Time-Accurate Turbopump Simulation Procedure Using Overset Grid System

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin; Chan, William; Kwak, Dochan

    2002-01-01

    The objective of the current effort is to provide a computational framework for design and analysis of the entire fuel supply system of a liquid rocket engine, including high-fidelity unsteady turbopump flow analysis. This capability is needed to support the design of pump sub-systems for advanced space transportation vehicles that are likely to involve liquid propulsion systems. To date, computational tools for design/analysis of turbopump flows are based on relatively lower fidelity methods. An unsteady, three-dimensional viscous flow analysis tool involving stationary and rotational components for the entire turbopump assembly has not been available for real-world engineering applications. The present effort provides developers with information such as transient flow phenomena at start up, and nonuniform inflows, and will eventually impact on system vibration and structures. In the proposed paper, the progress toward the capability of complete simulation of the turbo-pump for a liquid rocket engine is reported. The Space Shuttle Main Engine (SSME) turbo-pump is used as a test case for evaluation of the hybrid MPI/Open-MP and MLP versions of the INS3D code. CAD to solution auto-scripting capability is being developed for turbopump applications. The relative motion of the grid systems for the rotor-stator interaction was obtained using overset grid techniques. Unsteady computations for the SSME turbo-pump, which contains 114 zones with 34.5 million grid points, are carried out on Origin 3000 systems at NASA Ames Research Center. Results from these time-accurate simulations with moving boundary capability are presented along with the performance of parallel versions of the code.

  17. Accurate procedure for deriving UTI at a submilliarcsecond accuracy from Greenwich Sidereal Time or from the stellar angle

    NASA Astrophysics Data System (ADS)

    Capitaine, N.; Gontier, A.-M.

    1993-08-01

    Present observations using modern astrometric techniques are supposed to provide the Earth orientation parameters, and therefore UT1, with an accuracy better than ±1 mas. In practice, UT1 is determined through the intermediary of Greenwich Sidereal Time (GST), using both the conventional relationship between Greenwich Mean Sidereal Time (GMST) and UTl (Aoki et al. 1982) and the so-called "equation of the equinoxes" limited to the first order terms with respect to the nutation quantities. This highly complex relation between sidereal time and UT1 is not accurate at the milliaresecond level which gives rise to spurious terms of milliaresecond amplitude in the derived UTl. A more complete relationship between GST and UT1 has been recommended by Aoki & Kinoshita (1983) and Aoki (1991) taking into account the second order terms in the difference between GST and GM ST, the largest one having an amplitude of 2.64 mas and a 18.6 yr-period. This paper explains how this complete expansion of GST implicitly uses the concept of "nonrotating origin" (NRO) as proposed by Guinot in 1979 and would, therefore, provide a more accurate value of UTl and consequently of the Earth's angular velocity. This paper shows, moreover, that such a procedure would be simplified and conceptually clarified by the explicit use of the NRO as previously proposed (Guinot 1979; Capitaine et al. 1986). The two corresponding options (implicit or explicit use of the NRO) are shown to be equivalent for defining the specific Earth's angle of rotation and then UT1. The of the use of such an accurate procedure which has been proposed in the new IERS standards (McCarthy 1992a) instead of the usual one are estimated for the practical derivation of UT1.

  18. Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center

    PubMed Central

    Chun, Chang Woo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong-Sam

    2014-01-01

    Objective To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. Materials and Methods We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Results Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 ± 44.8 Gy-cm2, and 251 ± 49 frames for diagnostic procedures, 52.9 minutes, 226.0 ± 129.2 Gy-cm2, and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 ± 184.6 Gy-cm2, and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 ± 3.2 Gy-cm2. On average, rotational angiography was used 1.4 ± 0.6 times/session (range, 1-4; n = 580). Conclusion Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level. PMID:25469098

  19. [Hirschsprung-neurointestinal dyspasia: diferential diagnosis and reliability of diagnostic procedures].

    PubMed

    Gil-Vernet, J M; Broto, J; Guillén, G

    2006-04-01

    The suspicion of Hirschsprung's disease (HD) or Neurointestinal Dysplasia (NID) arises with the appearance of a common symtomatology : delay in meconium evacuation, abdominal distention, vomiting, intestinal occlusion and ultimately, chronic constipation. The need to perform a correct differential diagnosis between both pathologies is essential, given that the treatment of HD is surgical while NID is expectant. The objective of this paper is to define the necessity of using or not all the diagnostic tests simultaneously to obtain a precise diagnosis. The authors performed a complete clinical review of a series of 42 HD and 18 NID analysing the results of diagnostic procedures (Radiology / transition zone, anorrectal manometry / absence of anal inhibitory reflex, and suction biopsy / AcHE study). The authors concluded that is necessary to perform all the three diagnostic procedures simultaneously in all patients with symtomatology given that not one test has the capacity to provide a diagnosis alone. Anorectal manometry has proven to be the most reliable test to diagnose HD. The authors agree with the guidelines published by Meier Ruge in 2004 to diagnose NID. PMID:16846131

  20. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical...

  1. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical...

  2. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical...

  3. Diagnostic procedures for paraffin-embedded tissues analysis in pharmacogenomic studies.

    PubMed

    Palmirotta, Raffaele; De Marchis, Maria Laura; Ludovici, Giorgia; Ferroni, Patrizia; Abete, Pasquale; Guadagni, Fiorella; Della-Morte, David

    2014-01-01

    In this book chapter we report our own experience of mutational analysis in selecting tailored anticancer treatments for solid tumors. Our Department of Advanced Biotechnologies and Bioimaging, IRCCS San Raffaele Pisana, Rome, Italy, routinely performs pharmacogenetic screenings for different genes such as K-ras, BRAF, KIT, PDGFRα, and EGFR on paraffin-embedded cancer sections. Therefore, the chapter describes the mutational analysis procedures on paraffin-embedded tumors aimed to predict individual response to anticancer therapy. These molecular diagnostic methodologies may help us in improving the translational impact of genetic information on clinical practice. PMID:25150866

  4. Cognitive and emotional aspects of polygraph diagnostic procedures: a comment on Palmatier and Rovner (2015).

    PubMed

    Elaad, Eitan

    2015-01-01

    Palmatier and Rovner (2015) suggested that the Preliminary Process Theory (PPT) is a plausible theoretical account for explaining the rationale underlying two major polygraph tests, the Comparison Question Test (CQT) and the Concealed Information Test (CIT). To support their suggestion they claimed that both tests detect deception while relying on orienting responses. This approach is critically discussed. It was concluded that application of current scientific theories to polygraph diagnostic procedures should be done separately for the CIT and for the CQT. Finally, a call was extended for more research on unanswered questions in polygraph testing. PMID:25093905

  5. Validation of Three Early Ejaculation Diagnostic Tools: A Composite Measure Is Accurate and More Adequate for Diagnosis by Updated Diagnostic Criteria

    PubMed Central

    Jern, Patrick; Piha, Juhana; Santtila, Pekka

    2013-01-01

    Purpose To validate three early ejaculation diagnostic tools, and propose a new tool for diagnosis in line with proposed changes to diagnostic criteria. Significant changes to diagnostic criteria are expected in the near future. Available screening tools do not necessarily reflect proposed changes. Materials and Methods Data from 148 diagnosed early ejaculation patients (Mage = 42.8) and 892 controls (Mage = 33.1 years) from a population-based sample were used. Participants responded to three different questionnaires (Premature Ejaculation Profile; Premature Ejaculation Diagnostic Tool; Multiple Indicators of Premature Ejaculation). Stopwatch measured ejaculation latency times were collected from a subsample of early ejaculation patients. We used two types of responses to the questionnaires depending on the treatment status of the patients 1) responses regarding the situation before starting pharmacological treatment and 2) responses regarding current situation. Logistic regressions and Receiver Operating Characteristics were used to assess ability of both the instruments and individual items to differentiate between patients and controls. Results All instruments had very good precision (Areas under the Curve ranging from .93-.98). A new five-item instrument (named CHecklist for Early Ejaculation Symptoms – CHEES) consisting of high-performance variables selected from the three instruments had validity (Nagelkerke R2 range .51-.79 for backwards/forwards logistic regression) equal to or slightly better than any individual instrument (i.e., had slightly higher validity statistics, but these differences did not achieve statistical significance). Importantly, however, this instrument was more in line with proposed changes to diagnostic criteria. Conclusions All three screening tools had good validity. A new 5-item diagnostic tool (CHEES) based on the three instruments had equal or somewhat more favorable validity statistics compared to the other three tools, but is

  6. Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey

    PubMed Central

    Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    Objective We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. Materials and Methods We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. Results The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Conclusion Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion. PMID:26576117

  7. Are women in Kuwait aware of breast cancer and its diagnostic procedures?

    PubMed

    Saeed, Raed Saeed; Bakir, Yousif Yacoub; Ali, Layla Mohammed

    2014-01-01

    The aim of this study was to examine the knowledge and awareness of women in Kuwait with regard to risk factors, symptoms and diagnostic procedures of breast cancer. A total of 521 questionnaires were distributed among women in Kuwait. Results showed that 72% of respondents linked breast cancer factors to family history, while 69.7% scored abnormal breast enlargement as the most detectable symptom of the disease. Some 84% of participants had heard about self-examination, but knowledge about mammograms was limited to 48.6% and only 22.2% were familiar with diagnostic procedures. Some 22.9% of respondents identified the age over 40 years as the reasonable age to start mammogram screening. Risk factor awareness was independent on age groups (p>0.05), but both high education and family history increased the likelihood of postivie answers; the majority knew about a few factors such as aging, pregnancy after age 30, breast feeding for short time, menopause after age of 50, early puberty, and poor personal hygiene. In conclusion, 43.1% of participants had an overall good knowledge of breast cancer with regards to symptoms, risk factors and breast examination. Very highly significant associations (p<0.005) were evident for all groups except for respondents distributed by nationality (p=0.444). Early campaigns for screening the breast should be recommended to eliminate the confusion of wrong perceptions about malignant mammary disease. PMID:25124616

  8. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    SciTech Connect

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-11-30

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added.

  9. Reliability and Validity of a Procedure to Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    1990-01-01

    The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…

  10. Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India

    PubMed Central

    Saravanakumar, A.; Vaideki, K.; Govindarajan, K. N.; Jayakumar, S.

    2014-01-01

    Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDIw), volumetric CT dose index (CTDIv), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDIw, CTDIv, and DLP were calculated. The DRL is established based on the third quartile value of CTDIv and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level. PMID:24600173

  11. Bone marrow aspiration in north Sudan: the procedure, indications and the diagnostic value

    PubMed Central

    Elmadhoun, Wadie M; Noor, Sufian K; Bushara, Sarra O; Almobarak, Ahmed O; Husain, Nazik Elmalaika; Ahmed, Mohamed H

    2015-01-01

    Introduction Bone marrow aspiration (BMA) is a common and useful investigation tool in clinical practice to obtain information about both hematological and non-hematological disorders. The aim of the work was to identify the main indications for BMA in Atbara city, north Sudan and to determine the common diagnoses encountered. Methods All reports of BMA carried out during a 6-year period from 2009 to 2014, in the Modern Specialized Laboratory (the only site where BMA is conducted in Atbara) were reviewed. The information extracted included the main indications for performing this procedure, age groups involved, and the most common diagnoses established. A specially designed form was used for this purpose and the data were analyzed using SPSS computer program. Results A total number of 112 cases were subjected to bone marrow aspiration. The most frequent indications were: pancytopenia 43(38.4%), anemia 39 (34.8%), and suspected leukemia 13 (11.6%). In 86(76.8%) cases, BMA provided either the diagnosis or diagnostic clues to the disease process, while 26 (23.2%) of the aspirates revealed a normally functioning marrow. Conclusion Bone marrow aspiration is an important investigation for establishing the diagnosis in many medical conditions. The most common indication for this procedure in our study was pancytopenia and the most common finding was aplastic anemia. PMID:26715923

  12. Does ultrasonography accurately diagnose acute cholecystitis? Improving diagnostic accuracy based on a review at a regional hospital

    PubMed Central

    Hwang, Hamish; Marsh, Ian; Doyle, Jason

    2014-01-01

    Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607

  13. Developing an automated database for monitoring ultrasound- and computed tomography-guided procedure complications and diagnostic yield.

    PubMed

    Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M

    2014-04-01

    Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department. PMID:24146357

  14. Exposure reduction through quality assurance for diagnostic x-ray procedures.

    PubMed

    Lipoti, Jill A

    2008-11-01

    Traditional state x-ray inspection programs concentrate on measurement of x-ray machine parameters such as kVp and mAs, timer accuracy, collimation, etc. In 1996, the New Jersey radiation control program began a paradigm shift from the traditional inspection to an outcome-based inspection that concentrated on two indicators of performance: image quality and entrance skin exposure (ESE). Through extensive outreach and involvement of stakeholders, a new approach was designed that placed an emphasis on quality assurance. Key to the positive outcome has been the credentialing of medical physicists. On 16 January 2001, the final regulation titled "Quality Assurance Programs for Medical Diagnostic X-ray Installations" was adopted. The new regulations require that each facility using diagnostic medical x-ray equipment (including radiographic, fluoroscopic, x-ray bone densitometric, and computed tomographic) establish and carry out a quality assurance program. The new regulation specifies the quality control tests, frequencies, and standards that are part of the quality assurance program. Five years of data have been gathered. Both ESE and image quality are checked and the inspectors conduct an audit of the facility's quality assurance program. ESE has been decreased by 34% for lumbar spine, 46% for chest, and 66% for foot x-ray procedures. Image quality has improved by 22%. Quality improvement initiatives were extended to the larger dental x-ray community. Through outreach and information sharing, stakeholders were instructed in the factors that affect patient radiation exposure and image quality and were encouraged to take actions to improve in these areas. PMID:18849692

  15. A new automatic blood pressure kit auscultates for accurate reading with a smartphone: A diagnostic accuracy study.

    PubMed

    Wu, Hongjun; Wang, Bingjian; Zhu, Xinpu; Chu, Guang; Zhang, Zhi

    2016-08-01

    The widely used oscillometric automated blood pressure (BP) monitor was continuously questioned on its accuracy. A novel BP kit named Accutension which adopted Korotkoff auscultation method was then devised. Accutension worked with a miniature microphone, a pressure sensor, and a smartphone. The BP values were automatically displayed on the smartphone screen through the installed App. Data recorded in the phone could be played back and reconfirmed after measurement. They could also be uploaded and saved to the iCloud. The accuracy and consistency of this novel electronic auscultatory sphygmomanometer was preliminarily verified here. Thirty-two subjects were included and 82 qualified readings were obtained. The mean differences ± SD for systolic and diastolic BP readings between Accutension and mercury sphygmomanometer were 0.87 ± 2.86 and -0.94 ± 2.93 mm Hg. Agreements between Accutension and mercury sphygmomanometer were highly significant for systolic (ICC = 0.993, 95% confidence interval (CI): 0.989-0.995) and diastolic (ICC = 0.987, 95% CI: 0.979-0.991). In conclusion, Accutension worked accurately based on our pilot study data. The difference was acceptable. ICC and Bland-Altman plot charts showed good agreements with manual measurements. Systolic readings of Accutension were slightly higher than those of manual measurement, while diastolic readings were slightly lower. One possible reason was that Accutension captured the first and the last korotkoff sound more sensitively than human ear during manual measurement and avoided sound missing, so that it might be more accurate than traditional mercury sphygmomanometer. By documenting and analyzing of variant tendency of BP values, Accutension helps management of hypertension and therefore contributes to the mobile heath service. PMID:27512876

  16. Metadata requirements for results of diagnostic imaging procedures: a BIIF profile to support user applications

    NASA Astrophysics Data System (ADS)

    Brown, Nicholas J.; Lloyd, David S.; Reynolds, Melvin I.; Plummer, David L.

    2002-05-01

    A visible digital image is rendered from a set of digital image data. Medical digital image data can be stored as either: (a) pre-rendered format, corresponding to a photographic print, or (b) un-rendered format, corresponding to a photographic negative. The appropriate image data storage format and associated header data (metadata) required by a user of the results of a diagnostic procedure recorded electronically depends on the task(s) to be performed. The DICOM standard provides a rich set of metadata that supports the needs of complex applications. Many end user applications, such as simple report text viewing and display of a selected image, are not so demanding and generic image formats such as JPEG are sometimes used. However, these are lacking some basic identification requirements. In this paper we make specific proposals for minimal extensions to generic image metadata of value in various domains, which enable safe use in the case of two simple healthcare end user scenarios: (a) viewing of text and a selected JPEG image activated by a hyperlink and (b) viewing of one or more JPEG images together with superimposed text and graphics annotation using a file specified by a profile of the ISO/IEC Basic Image Interchange Format (BIIF).

  17. Procedure for computer-controlled milling of accurate surfaces of revolution for millimeter and far-infrared mirrors

    NASA Technical Reports Server (NTRS)

    Emmons, Louisa; De Zafra, Robert

    1991-01-01

    A simple method for milling accurate off-axis parabolic mirrors with a computer-controlled milling machine is discussed. For machines with a built-in circle-cutting routine, an exact paraboloid can be milled with few computer commands and without the use of the spherical or linear approximations. The proposed method can be adapted easily to cut off-axis sections of elliptical or spherical mirrors.

  18. A survey of close contact regimes between patients undergoing diagnostic radioisotope procedures and children.

    PubMed

    Greaves, C D; Tindale, W B; Flynn, P J

    1996-07-01

    When following diagnostic radioisotope procedures, UK legislation requires that we advise patients to avoid close contact with children [1, 2]. How does this advice affect the average nuclear medicine patient? Over a 4 month period, 90 patients in contact with children were asked about their home circumstances, how they coped with avoidance of close contact and the problems caused. On average, the patients were in contact with two children with a mean age of 7 years. Thirty-nine per cent of patients spent < 5 h per day and 30% between 5 and 10 h per day in close contact. However, 13% spent 20-24 h in close contact with children. For most patients (55%), it is easy to avoid close contact, but 25% found it difficult or very difficult. The average in-patient received one visit a day from children of 0.5-1 h duration and 65% of children sat on the patient's bed. Restriction of visits was a problem for 14% of patients. Initially, over one-third of the out-patients felt a medium level of anxiety or higher regarding close contact with children. Given more detailed written information and the opportunity to discuss any queries with a member of staff (70% wished to do so), the proportion fell to less than one-tenth. We found it important to question patients carefully, because home circumstances and levels of close contact cannot be deduced from the age of the child or the relationship between the child and the patient. PMID:8843113

  19. Evaluating diagnostic tests.

    PubMed

    Kennedy, Ashley Graham

    2016-08-01

    Although much has been written on the role of randomized controlled trials and mechanistic reasoning in the evaluation of therapeutic treatments, philosophers of medicine have not yet turned their attention to the question of how diagnostic tests and procedures should be evaluated. I aim to begin to fill this gap by examining each of the following questions: What is the best way to determine the accuracy of a diagnostic test? What is the best way to determine the clinical effectiveness of a diagnostic test? Can an accurate diagnostic test be considered medically valuable even if it is not clinically effective? I argue that while diagnostic accuracy is a minimum requirement for both clinical effectiveness and medical value, accuracy and effectiveness are not sufficient for determining the value of a diagnostic test, because diagnostic value extends beyond patient outcomes. PMID:27091221

  20. Watch the target! Effects in the affective misattribution procedure become weaker (but not eliminated) when participants are motivated to provide accurate responses to the target

    PubMed Central

    Eder, Andreas B.; Deutsch, Roland

    2015-01-01

    Previous research showed that priming effects in the affective misattribution procedure (AMP) are unaffected by direct warnings to avoid an influence of the primes. The present research examined whether a priming influence is diminished by task procedures that encourage accurate judgments of the targets. Participants were motivated to categorize the affective meaning of nonsense targets accurately by being made to believe that a true word was presented in each trial and by providing feedback on (allegedly) incorrect responses. This condition produced robust priming effects. Priming was however reduced and less reliable relative to more typical AMP conditions in which participants guessed the meaning of openly presented nonsense targets. Affective judgments of nonsense targets were not affected by advance knowledge of the response mapping during the priming phase, which argues against a response-priming explanation of AMP effects. These findings show that affective primes influence evaluative judgments even in conditions in which the motivation to provide accurate responses is high and a priming of motor responses is not possible. Priming effects were however weaker with high accuracy motivation, suggesting that a focus on accurate judgments is an effective strategy to control for an unwanted priming influence in the AMP. PMID:26441807

  1. Watch the target! Effects in the affective misattribution procedure become weaker (but not eliminated) when participants are motivated to provide accurate responses to the target.

    PubMed

    Eder, Andreas B; Deutsch, Roland

    2015-01-01

    Previous research showed that priming effects in the affective misattribution procedure (AMP) are unaffected by direct warnings to avoid an influence of the primes. The present research examined whether a priming influence is diminished by task procedures that encourage accurate judgments of the targets. Participants were motivated to categorize the affective meaning of nonsense targets accurately by being made to believe that a true word was presented in each trial and by providing feedback on (allegedly) incorrect responses. This condition produced robust priming effects. Priming was however reduced and less reliable relative to more typical AMP conditions in which participants guessed the meaning of openly presented nonsense targets. Affective judgments of nonsense targets were not affected by advance knowledge of the response mapping during the priming phase, which argues against a response-priming explanation of AMP effects. These findings show that affective primes influence evaluative judgments even in conditions in which the motivation to provide accurate responses is high and a priming of motor responses is not possible. Priming effects were however weaker with high accuracy motivation, suggesting that a focus on accurate judgments is an effective strategy to control for an unwanted priming influence in the AMP. PMID:26441807

  2. CT-guided percutaneous aspiration of Tarlov cyst as a useful diagnostic procedure prior to operative intervention.

    PubMed

    Lee, J-Y; Impekoven, P; Stenzel, W; Löhr, M; Ernestus, R-I; Klug, N

    2004-07-01

    Tarlov or perineural cysts are lesions of the nerve root most often found in the sacral region. Several authors recommend surgical treatment of symptomatic Tarlov cysts. However, successful surgical treatment is dependent on appropriate patient selection. In this article, we report three cases of a sacral perineural cyst, causing sciatic pain, and emphasize the usefulness of CT-guided percutaneous aspiration as an important diagnostic and prognostic procedure prior to definitive operative treatment. PMID:15197609

  3. Accurately evaluating Young's modulus of polymers through nanoindentations: A phenomenological correction factor to the Oliver and Pharr procedure

    NASA Astrophysics Data System (ADS)

    Tranchida, Davide; Piccarolo, Stefano; Loos, Joachim; Alexeev, Alexander

    2006-10-01

    The Oliver and Pharr [J. Mater. Res. 7, 1564 (1992)] procedure is a widely used tool to analyze nanoindentation force curves obtained on metals or ceramics. Its application to polymers is, however, difficult, as Young's moduli are commonly overestimated mainly because of viscoelastic effects and pileup. However, polymers spanning a large range of morphologies have been used in this work to introduce a phenomenological correction factor. It depends on indenter geometry: sets of calibration indentations have to be performed on some polymers with known elastic moduli to characterize each indenter.

  4. A Rapid and Accurate Extraction Procedure for Analysing Free Amino Acids in Meat Samples by GC-MS

    PubMed Central

    Barroso, Miguel A.; Ruiz, Jorge; Antequera, Teresa

    2015-01-01

    This study evaluated the use of a mixer mill as the homogenization tool for the extraction of free amino acids in meat samples, with the main goal of analyzing a large number of samples in the shortest time and minimizing sample amount and solvent volume. Ground samples (0.2 g) were mixed with 1.5 mL HCl 0.1 M and homogenized in the mixer mill. The final biphasic system was separated by centrifugation. The supernatant was deproteinized, derivatized and analyzed by gas chromatography. This procedure showed a high extracting ability, especially in samples with high free amino acid content (recovery = 88.73–104.94%). It also showed a low limit of detection and quantification (3.8 · 10−4–6.6 · 10−4 μg μL−1 and 1.3 · 10−3–2.2 · 10−2 μg μL−1, resp.) for most amino acids, an adequate precision (2.15–20.15% for run-to-run), and a linear response for all amino acids (R2 = 0.741–0.998) in the range of 1–100 µg mL−1. Moreover, it takes less time and requires lower amount of sample and solvent than conventional techniques. Thus, this is a cost and time efficient tool for homogenizing in the extraction procedure of free amino acids from meat samples, being an adequate option for routine analysis. PMID:25873963

  5. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    NASA Astrophysics Data System (ADS)

    Oliveira, L. S. R.; Conti, C. C.; Amorim, A. S.; Balthar, M. C. V.

    2013-03-01

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector's materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  6. Italian Frontotemporal Dementia Network (FTD Group-SINDEM): sharing clinical and diagnostic procedures in Frontotemporal Dementia in Italy.

    PubMed

    Borroni, B; Turrone, R; Galimberti, D; Nacmias, B; Alberici, A; Benussi, A; Caffarra, P; Caltagirone, C; Cappa, S F; Frisoni, G B; Ghidoni, R; Marra, C; Padovani, A; Rainero, I; Scarpini, E; Silani, V; Sorbi, S; Tagliavini, F; Tremolizzo, L; Bruni, A C

    2015-05-01

    In the prospect of improved disease management and future clinical trials in Frontotemporal Dementia, it is desirable to share common diagnostic procedures. To this aim, the Italian FTD Network, under the aegis of the Italian Neurological Society for Dementia, has been established. Currently, 85 Italian Centers involved in dementia care are part of the network. Each Center completed a questionnaire on the local clinical procedures, focused on (1) clinical assessment, (2) use of neuroimaging and genetics; (3) support for patients and caregivers; (4) an opinion about the prevalence of FTD. The analyses of the results documented a comprehensive clinical and instrumental approach to FTD patients and their caregivers in Italy, with about 1,000 newly diagnosed cases per year and 2,500 patients currently followed by the participating Centers. In analogy to other European FTD consortia, future aims will be devoted to collect data on epidemiology of FTD and its subtypes and to provide harmonization of procedures among Centers. PMID:25528460

  7. [Vascular anomaly in the midcheek region of an infant--review of the diagnostic procedure].

    PubMed

    Rossler, L; Sander, V; Teuber, I; Stücker, M; Kreuter, A; Stricker, I; Hamelmann, E

    2015-05-01

    Clinical history, physical examination, evolution and imaging findings (Colour Doppler sonography, MRI if available) are of pivotal importance in the diagnostic pathway of an infantile vascular anomaly. Histopathology with specific stains and markers is contributive in difficult cases. Differentiation between vascular tumors (hemangioma) and vascular malformations is now well known and integrated into the ISSVA classification. We report here a 6-months-old boy, who presented with a localized cutaneous and expansive vascular birthmark in the left cheek and developed bleedings at the age of 18 months. Diagnostic features of a hemangioma were not evident, and the final diagnosis of a venous malformation was confirmed by histopathology. PMID:25985453

  8. Measuring the Academic Skills of University Students: Evaluation of a Diagnostic Procedure

    ERIC Educational Resources Information Center

    Erling, Elizabeth J.; Richardson, John T. E.

    2010-01-01

    Measuring the Academic Skills of University Students is a procedure developed in the 1990s at the University of Sydney's Language Centre to identify students in need of academic writing development by assessing examples of their written work against five criteria. This paper reviews the literature relating to the development of the procedure with…

  9. Diagnostic procedures for Trend Monitoring System (TMS) communications. [coaxial cable bus system

    NASA Technical Reports Server (NTRS)

    Brown, J. S.; Lenker, M. D.

    1979-01-01

    A prototype coaxial cable bus communications sytem was developed to support the trend monitoring system (TMS). Troubleshooting procedures are described at the system level. The procedures can be used by repair personnel to isolate a fault in the TMS and to restore the system to operation by swapping out failed components.

  10. Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures; Federal Guidance Report No. 14

    EPA Science Inventory

    Federal Guidance Report No. 14 provides federal facilities that use diagnostic and interventional x-ray equipment with updated recommendations for keeping doses as low as reasonably achievable without compromising the quality of patient care, This guidance is an update of Federal...

  11. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests.

    PubMed

    Shan, Guogen; Amei, Amei; Young, Daniel

    2015-01-01

    Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003). However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization. PMID:26366190

  12. Explicitly correlated benchmark calculations on C8H8 isomer energy separations: how accurate are DFT, double-hybrid, and composite ab initio procedures?

    NASA Astrophysics Data System (ADS)

    Karton, Amir; Martin, Jan M. L.

    2012-10-01

    Accurate isomerization energies are obtained for a set of 45 C8H8 isomers by means of the high-level, ab initio W1-F12 thermochemical protocol. The 45 isomers involve a range of hydrocarbon functional groups, including (linear and cyclic) polyacetylene, polyyne, and cumulene moieties, as well as aromatic, anti-aromatic, and highly-strained rings. Performance of a variety of DFT functionals for the isomerization energies is evaluated. This proves to be a challenging test: only six of the 56 tested functionals attain root mean square deviations (RMSDs) below 3 kcal mol-1 (the performance of MP2), namely: 2.9 (B972-D), 2.8 (PW6B95), 2.7 (B3PW91-D), 2.2 (PWPB95-D3), 2.1 (ωB97X-D), and 1.2 (DSD-PBEP86) kcal mol-1. Isomers involving highly-strained fused rings or long cumulenic chains provide a 'torture test' for most functionals. Finally, we evaluate the performance of composite procedures (e.g. G4, G4(MP2), CBS-QB3, and CBS-APNO), as well as that of standard ab initio procedures (e.g. MP2, SCS-MP2, MP4, CCSD, and SCS-CCSD). Both connected triples and post-MP4 singles and doubles are important for accurate results. SCS-MP2 actually outperforms MP4(SDQ) for this problem, while SCS-MP3 yields similar performance as CCSD and slightly bests MP4. All the tested empirical composite procedures show excellent performance with RMSDs below 1 kcal mol-1.

  13. Diagnostic procedures for non-small-cell lung cancer (NSCLC): recommendations of the European Expert Group

    PubMed Central

    Dietel, Manfred; Bubendorf, Lukas; Dingemans, Anne-Marie C; Dooms, Christophe; Elmberger, Göran; García, Rosa Calero; Kerr, Keith M; Lim, Eric; López-Ríos, Fernando; Thunnissen, Erik; Van Schil, Paul E; von Laffert, Maximilian

    2016-01-01

    Background There is currently no Europe-wide consensus on the appropriate preanalytical measures and workflow to optimise procedures for tissue-based molecular testing of non-small-cell lung cancer (NSCLC). To address this, a group of lung cancer experts (see list of authors) convened to discuss and propose standard operating procedures (SOPs) for NSCLC. Methods Based on earlier meetings and scientific expertise on lung cancer, a multidisciplinary group meeting was aligned. The aim was to include all relevant aspects concerning NSCLC diagnosis. After careful consideration, the following topics were selected and each was reviewed by the experts: surgical resection and sampling; biopsy procedures for analysis; preanalytical and other variables affecting quality of tissue; tissue conservation; testing procedures for epidermal growth factor receptor, anaplastic lymphoma kinase and ROS proto-oncogene 1, receptor tyrosine kinase (ROS1) in lung tissue and cytological specimens; as well as standardised reporting and quality control (QC). Finally, an optimal workflow was described. Results Suggested optimal procedures and workflows are discussed in detail. The broad consensus was that the complex workflow presented can only be executed effectively by an interdisciplinary approach using a well-trained team. Conclusions To optimise diagnosis and treatment of patients with NSCLC, it is essential to establish SOPs that are adaptable to the local situation. In addition, a continuous QC system and a local multidisciplinary tumour-type-oriented board are essential. PMID:26530085

  14. Comparison of the BD MAX® Enteric Bacterial Panel assay with conventional diagnostic procedures in diarrheal stool samples.

    PubMed

    Knabl, L; Grutsch, I; Orth-Höller, D

    2016-01-01

    Although infectious diarrhea is one of the most predominant diseases around the world, the identification of the causative microorganism is still challenging. The aim of this study was the evaluation of the BD MAX® Enteric Bacterial Panel assay in comparison to conventional diagnostic procedures concerning the detection of the enteric pathogens Salmonella spp., Campylobacter spp., Shigella spp., and Shiga toxin-producing Escherichia coli. For this purpose, 971 prospectively collected stool samples were evaluated. Utilization of the BD MAX Enteric Bacterial Panel elevated the overall detection rate from 5.26 % to 8.06 %. The positive percent agreement of the BD MAX Enteric Bacterial Panel assay and stool culture or enzyme immunoassay was 0.97 for Campylobacter spp., 0.75 for Salmonella spp., 1.00 for Shigella spp., and 0.88 for Shiga toxins. Furthermore, a negative percent agreement of 0.98 for Campylobacter spp., 0.99 for Salmonella spp., 0.99 for Shigella spp., and 0.99 for Shiga toxins has been demonstrated. This study highlighted the superior detection rate of molecular assays compared to conventional diagnostic procedures. PMID:26563899

  15. The Australian experiment: the use of evidence based medicine for the reimbursement of surgical and diagnostic procedures (1998–2004)

    PubMed Central

    O'Malley, Sue P

    2006-01-01

    Background In 1998 a formal process using the criteria of safety, effectiveness and cost-effectiveness (evidence based medicine) on the introduction and use of new medical procedures was implemented in Australia. As part of this process an expert panel, the Medical Services Advisory Committee (MSAC) was set up. This paper examines the effectiveness of this process based on the original criteria, that is, evidence based medicine. Method The data for this analysis was sourced primarily from that made available in the public domain. The MSAC web site provided Minutes from MSAC meetings; Annual Reports; Assessment and Review reports; Progress status; and Archived material. Results The total number of applications submitted to the MSAC has been relatively low averaging approximately only fourteen per year. Additionally, the source of applications has quickly shifted to the medical devices, equipment and diagnostic industry as being the major source of applications. An overall average time for the processing of an application is eighteen months. Negative recommendations were in most cases based on insufficient clinical evidence rather than clinical evidence that clearly demonstrated a lack of clinical effectiveness. It was rare for a recommendation, either positive or negative, to be based on cost-effectiveness. Conclusion New medical procedures are often the result of a process of experimentation rather than formally conducted research. Affordability and the question of who should pay for the generation, collection and analysis of the clinical evidence is perhaps the most difficult to answer. This is especially the case where the new procedure is the result of a process of experimentation with an old procedure. A cost-effective way needs to be found to collect acceptable levels of evidence proving the clinical effectiveness of these new procedures, otherwise the formal processes of evaluation such as that used by the Australian MSAC since 1998 will continue to run the

  16. Molecular diagnostic procedures for production of pathogen-free propagation material.

    PubMed

    Manulis, Shulamit; Chalupowicz, Laura; Dror, Orit; Kleitman, Frida

    2002-11-01

    Production of disease-free propagation material is a major means of controlling most bacterial diseases of plants, particularly when neither resistant clones nor effective chemical treatments are available. For this purpose sensitive, specific and rapid detection methods are required. The advent of molecular biology and, in particular, the polymerase chain reaction (PCR) has opened new ways for the characterization and identification of plant pathogens and the development of disease-management strategies. PCR-based detection methods rely on the development of primers for the specific detection of the pathogen. The use of pathogenicity genes as targets for primer design is the preferred procedure for obtaining specific primers but other procedures may also be useful for this purpose. In the present review we describe four examples of procedures for detecting four important bacterial pathogens in Israel: Erwinia herbicola pv gypsophilae in gypsophila, Xanthomonas campestris pv pelargonii in geranium, Agrobacterium tumefaciens in asters and roses, and Xanthomonas campestris pv campestris in crucifers. Procedures for constructing specific PCR primers for each bacterium are illustrated and discussed as well as the combination of PCR with other methods. PMID:12449531

  17. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures.

    PubMed

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P

    2012-04-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging. PMID:22639482

  18. Characterization of amorphous thermoluminescence dosimeters for patient dose measurement in X-ray diagnostic procedures

    NASA Astrophysics Data System (ADS)

    Ramli, N. N. H.; Salleh, H.; Mahdiraji, G. A.; Zulkifli, M. I.; Hashim, S.; Bradley, D. A.; M. Noor, N.

    2015-11-01

    We investigate the use of novel Ge-doped amorphous silica flat fibers as thermoluminescence dosimeters (TLDs) in verifying patient entrance surface-dose (ESD) in diagnostic examinations. Selected fibers with established dosimetric characteristics (including energy dependence, linearity, reproducibility, and fading) were loaded into plastic capsules in groups of six. The fibers have been calibrated against a parallel plate ionization chamber, use being made of x-rays generated at 70 kVp, accessing a Secondary Standards Dosimetry Laboratory (SSDL) facility. The fiber characterization measurements were made using a Toshiba X-ray machine operating within the nominal energies range 40 kVp to 150 kVp, for doses in the range 0.02 mGy up to 3 mGy. For doses from 2 mGy up to 150 mGy, the flat fibers exhibit linearity between TL yield and dose, reproducible to better than 3% standard deviation following repeat measurements (n=3). A marked energy-dependent response is observed for photons generated at potentials from 40 kVp to 150 kVp. From present results, it is concluded that Ge-doped fibers represent a viable system for use in diagnostic dosimetry, corrections being made for the various factors influencing TL yield.

  19. Work-related stress and bullying: gender differences and forensic medicine issues in the diagnostic procedure

    PubMed Central

    2011-01-01

    Background The attention of international agencies and scientific community on bullying and work-related stress is increasing. This study describes the gender differences found in victims of bullying and work-related stress in an Italian case series and analyzes the critical issues in the diagnostic workup. Methods Between 2001 and 2009 we examined 345 outpatients (148 males, 197 females; mean age: 41 ± 10.49) for suspected psychopathological work-related problems. Diagnosis of bullying was established using international criteria (ICD-10 and DSM-IV). Results After interdisciplinary diagnostic evaluation (Occupational Medicine Unit, Psychology and Psychiatry Service), the diagnosis of bullying was formulated in 35 subjects, 12 males and 23 females (2 cases of Post-Traumatic Stress Disorder and 33 of Adjustment Disorder). Fifty-four (20 males, 34 females) suffered from work-related anxiety, while work-unrelated Adjustment Disorder and other psychiatric disorders were diagnosed in 7 and 112 subjects, respectively. Women between 34 and 45 years showed a high prevalence (65%) of "mobbing syndrome" or other work-related stress disorders. Conclusions At work, women are more subject to harassment (for personal aspects related to emotional and relational factors) than men. The knowledge of the phenomenon is an essential requisite to contrast bullying; prevention can be carried out only through effective information and training of workers and employers, who have the legal obligation to preserve the integrity of the mental and physical status of their employees during work. PMID:22088163

  20. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures

    PubMed Central

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P.

    2012-01-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging. PMID:22639482

  1. Accurate and self-consistent procedure for determining pH in seawater desalination brines and its manifestation in reverse osmosis modeling.

    PubMed

    Nir, Oded; Marvin, Esra; Lahav, Ori

    2014-11-01

    Measuring and modeling pH in concentrated aqueous solutions in an accurate and consistent manner is of paramount importance to many R&D and industrial applications, including RO desalination. Nevertheless, unified definitions and standard procedures have yet to be developed for solutions with ionic strength higher than ∼0.7 M, while implementation of conventional pH determination approaches may lead to significant errors. In this work a systematic yet simple methodology for measuring pH in concentrated solutions (dominated by Na(+)/Cl(-)) was developed and evaluated, with the aim of achieving consistency with the Pitzer ion-interaction approach. Results indicate that the addition of 0.75 M of NaCl to NIST buffers, followed by assigning a new standard pH (calculated based on the Pitzer approach), enabled reducing measured errors to below 0.03 pH units in seawater RO brines (ionic strength up to 2 M). To facilitate its use, the method was developed to be both conceptually and practically analogous to the conventional pH measurement procedure. The method was used to measure the pH of seawater RO retentates obtained at varying recovery ratios. The results matched better the pH values predicted by an accurate RO transport model. Calibrating the model by the measured pH values enabled better boron transport prediction. A Donnan-induced phenomenon, affecting pH in both retentate and permeate streams, was identified and quantified. PMID:25058737

  2. Degree of Vertical Integration Between the Undergraduate Program and Clinical Internship With Respect to Cervical and Cranial Diagnostic and Therapeutic Procedures Taught at the Canadian Memorial Chiropractic College

    PubMed Central

    Leppington, Charmody; Gleberzon, Brian; Fortunato, Lisa; Doucet, Nicolea; Vandervalk, Kyle

    2012-01-01

    Objective: The purpose of this study was to determine if diagnostic and therapeutic procedures for the cervical and cranial spine taught to students during the undergraduate program at Canadian Memorial Chiropractic College are required to be used during their internship by their supervising clinicians and, if so, to what extent these procedures are used. Methods: Course manuals and course syllabi from the Applied Chiropractic and Clinical Diagnosis faculty of the undergraduate chiropractic program for the academic year 2009–2010 were consulted and a list of all diagnostic and therapeutic procedures for the cranial and cervical spine was compiled. This survey asked clinicians to indicate if they themselves used or if they required the students they were supervising to use each procedure listed and, if so, to what extent each procedure was used. Demographic information of each clinician was also obtained. Results: In general, most diagnostic procedures of the head and neck were seldom used, with the exception of postural observation and palpation. By contrast, most cervical orthopaedic tests were often used, with the exception of tests for vertigo. Most therapeutic procedures were used frequently with the exception of prone cervical and “muscle” adjustments. Conclusion: There was a low degree of vertical integration for cranial procedures as compared to a much higher degree of vertical integration for cervical procedures between the undergraduate and clinical internship programs taught. Vertical integration is an important element of curricular planning and these results may be helpful to aid educators to more appropriately allocate classroom instruction PMID:22778531

  3. Evaluation of diagnostic procedures for subclinical mastitis in meat-producing sheep.

    PubMed

    Clements, Archie C A; Taylor, David J; Fitzpatrick, Julie L

    2003-05-01

    Samples of foremilk were collected from 261 clinically normal glands of 150 ewes, and tested using the California mastitis test (CMT). Further samples were collected from 195 of these glands for determination of automated somatic cell counts (SCC), and from 60 of these glands for bacteriological assessment. The sensitivity and specificity of CMT for detecting samples with SCC above different threshold levels and for CMT and SCC in determining bacteriological status were evaluated using two-graph receiver operating characteristics (TG-ROC). Milk samples were obtained subsequently from ten CMT positive, and five CMT negative first- and second-lactation ewes. Samples were cultured using a variety of media, incubation temperatures and atmospheric conditions, immediately after collection, and 1 week after storage at 4 degrees C and -21 degrees C. Results suggested that CMT is best used as a diagnostic test for ovine subclinical mastitis (SCM) with a cut-off of 3 (distinct gel formation), and that automated SCC thresholds of > 1200 x 10(3) cells/ml are appropriate, especially where low prevalences are expected (e.g. < 5%). Additionally, this study showed that routine bacteriological methods were appropriate for isolation of most species of pathogen responsible for ovine SCM, but storage of samples prior to culture, either at 4 degrees C or -21 degrees C, was detrimental to the isolation of several of these organisms. PMID:12800867

  4. Smart on-board diagnostic decision trees for quantitative aviation equipment and safety procedures validation

    NASA Astrophysics Data System (ADS)

    Ali, Ali H.; Markarian, Garik; Tarter, Alex; Kölle, Rainer

    2010-04-01

    The current trend in high-accuracy aircraft navigation systems is towards using data from one or more inertial navigation subsystem and one or more navigational reference subsystems. The enhancement in fault diagnosis and detection is achieved via computing the minimum mean square estimate of the aircraft states using, for instance, Kalman filter method. However, this enhancement might degrade if the cause of a subsystem fault has some effect on other subsystems that are calculating the same measurement. One instance of such case is the tragic incident of Air France Flight 447 in June, 2009 where message transmissions in the last moment before the crash indicated inconsistencies in measured airspeed as reported by Airbus. In this research, we propose the use of mathematical aircraft model to work out the current states of the airplane and in turn, using these states to validate the readings of the navigation equipment throughout smart diagnostic decision tree network. Various simulated equipment failures have been introduced in a controlled environment to proof the concept of operation. The results have showed successful detection of the failing equipment in all cases.

  5. Frequency of use of diagnostic and manual therapeutic procedures of the spine currently taught at the Canadian Memorial Chiropractic College: A preliminary survey of Ontario chiropractors. Part 2 – procedure usage rates

    PubMed Central

    Gleberzon, Brian; Stuber, Kent

    2013-01-01

    Objective: The purpose of this study was to determine which diagnostic and therapeutic procedures of the spine are most commonly utilized by chiropractors practicing in Ontario, based on a list of currently taught procedures at CMCC. In Part 1 of this study (published previously), the demographics and practice patterns of the respondents were presented. Part 2 of this study (presented here) reports on the utilization rates of spinal diagnostic and therapeutic procedures by the respondents. Methods: The study consisted of a paper-based survey that was sent to 500 randomly selected Ontario chiropractors who responded confidentially. Survey questions inquired into demographic and practice style characteristics as well as the frequency with which spinal diagnostic and therapeutic procedures were performed. Results: There were 108 respondents to the survey, giving a response rate of 22.4%. Frequency of use of diagnostic procedures fell into three broad categories: (i) those tests that are almost always performed, (ii) those tests that are almost always performed by two-thirds to one-half of patients, and (iii) those tests that are virtually never used. By comparison, respondents utilized the same therapeutic procedures for patients care less consistently. Conclusions: Despite a low response rate, respondents reported mostly relying on static and motion palpation, joint play, neurological tests, and ranges of motion when assessing their patients. Due to a low response rate, the results of this study may not be generalizable to all Ontario chiropractors. PMID:23754862

  6. [Quality of diagnostic procedures and frequency of endoscopically defined diseases of the upper gastrointestinal tract].

    PubMed

    Bartels, F; Hahn, H-J; Stolte, M; Schmidt-Wilcke, H A

    2003-04-01

    (diagnosis histologically confirmed) were found with the same ratio of the diffuse type and the intestinal type. In 18 patients a carcinoma could be detected in the neighbouring area of gastric ulcers. The endoscopic findings in this investigation do not differ significantly from the results found in literature. It is important that there are more gastric ulcers than duodenal ulcers. This can be explained by the frequent use of PPIs which are prescribed additionally to NSARs and ASS. The deficits of histological diagnostics on Barett's oesophagus and gastritis were remarkable. An improvement of the endoscopic and histologic assessment quality by valid standards systematically applied should be aimed at in future. Furthermore it could be helpful to use the same nomenclature for pathologic findings to intensify the co-operation between the physicians in hospitals and the practitioners. PMID:12695936

  7. Pulmonary infiltrates in non-HIV immunocompromised patients: a diagnostic approach using non-invasive and bronchoscopic procedures

    PubMed Central

    Rano, A; Agusti, C; Jimenez, P; Angrill, J; Benito, N; Danes, C; Gonzalez, J; Rovira, M; Pumarola, T; Moreno, A; Torres, A

    2001-01-01

    %); and TBAS 35/55 (65%). Bronchoscopic techniques led to the diagnosis of pulmonary infiltrates in 59% of the cases in which they were used: FBAS 16/28 (57%), BAL 68/135 (51%), and PSB 30/125 (24%). The results obtained with the different techniques led to a change in antibiotic treatment in 93 cases (46%). Although changes in treatment did not have an impact on the overall mortality, patients with pulmonary infiltrates of an infectious aetiology in whom the change was made during the first 7 days had a better outcome (29% mortality) than those in whom treatment was changed later (71% mortality; p=0.001).
CONCLUSIONS—Non-invasive and bronchoscopic procedures are useful techniques for the diagnosis of pulmonary infiltrates in immunocompromised patients. Bronchial aspirates (FBAS and TBAS) and BAL have the highest diagnostic yield and impact on therapeutic decisions.

 PMID:11312407

  8. National decline in invasive prenatal diagnostic procedures in association with uptake of combined first trimester and cell-free DNA aneuploidy screening.

    PubMed

    Robson, Stephen J; Hui, Lisa

    2015-10-01

    In late 2012, a new screening test for fetal aneuploidy based on circulating cell-free DNA (cfDNA) became available to Australian women. The introduction of this technology in the United States has led to a reduction in invasive diagnostic procedures. Analysis of the number of amniocentesis and chorionic villus sampling (CVS) procedures performed in Australia from 1994 to 2014 shows that the introduction of cfDNA testing has been associated with the most rapid decline in invasive procedures in the last 20 years. This change has important implications for training in, and maintenance of, the procedural skills of amniocentesis and CVS. PMID:26259499

  9. Cotton-based diagnostic devices.

    PubMed

    Lin, Shang-Chi; Hsu, Min-Yen; Kuan, Chen-Meng; Wang, Hsi-Kai; Chang, Chia-Ling; Tseng, Fan-Gang; Cheng, Chao-Min

    2014-01-01

    A good diagnostic procedure avoids wasting medical resources, is easy to use, resists contamination, and provides accurate information quickly to allow for rapid follow-up therapies. We developed a novel diagnostic procedure using a "cotton-based diagnostic device" capable of real-time detection, i.e., in vitro diagnostics (IVD), which avoids reagent contamination problems common to existing biomedical devices and achieves the abovementioned goals of economy, efficiency, ease of use, and speed. Our research reinforces the advantages of an easy-to-use, highly accurate diagnostic device created from an inexpensive and readily available U.S. FDA-approved material (i.e., cotton as flow channel and chromatography paper as reaction zone) that adopts a standard calibration curve method in a buffer system (i.e., nitrite, BSA, urobilinogen and uric acid assays) to accurately obtain semi-quantitative information and limit the cross-contamination common to multiple-use tools. Our system, which specifically targets urinalysis diagnostics and employs a multiple biomarker approach, requires no electricity, no professional training, and is exceptionally portable for use in remote or home settings. This could be particularly useful in less industrialized areas. PMID:25393975

  10. Diagnostic Tests and Procedures

    MedlinePlus

    ... your heart with a stethoscope. This is called auscultation, which means the study of heart sounds. Doctors ... diagnose some types of heart valve disease by listening to any abnormal heart sounds that they hear ...

  11. [Patient compliance and efficacy of diagnostic procedures in the surveillance of colorectal cancer: experience from a cancer center].

    PubMed

    Riedl, S; Lux, T; Abel, U; Theuer, D

    2005-04-01

    Postoperative surveillance is an important part of the curative therapy of colorectal cancer patients. The effort and effectiveness of these surveillance programs are controversially discussed. We analyzed the practiced follow-up of patients who had undergone a curative resection of colorectal cancer to demonstrate the difficulty to validate the performed surveillance program and to point out possible improvements. For a follow-up period of 37 months (median) we included 530 patients with at least one postoperative examination. 70 patients ended the follow-up prematurely - out of these 56 % quit the surveillance during the first 18 months. Another 68 patients died during the follow-up period. Cancer recurred in 28 % of the patients (n = 109 metastasis, n = 26 local recurrences, 18 patients developed a secondary cancer). 90 % of these recurrences occurred within the first three years. 3525 follow-up examinations took place within 79 months. Patient histories and physical examinations were not helpful for the diagnosis of local recurrences; neither were laboratory routine screenings meaningful. Carcinoembryonic antigen (CEA) and CA 19 - 9 tests, ultrasonographic studies, chest XD-rays and colonoscopic procedures had a higher diagnostic value on the other hand. We demonstrated the problematic nature of the evaluation of different follow-up tests concerning their validity as they were part of a complex postoperative surveillance program. It is also important to point out that the success of the postoperative surveillance depends strongly on the compliance of the patients. To increase this compliance we suggest that the follow-up of patients should be more strongly oriented towards the incidence of recurrences. PMID:15830301

  12. Evaluation of triple stage mass spectrometry as a robust and accurate diagnostic tool for determination of free cordycepin in designer egg.

    PubMed

    Chen, Yi Hsin; Lim, Chee Wei; Chan, Sheot Harn

    2014-05-01

    Direct determination of free cordycepin in designer egg using a highly selective mass spectrometric (MS) technique aided by a rapid and efficient dilute-and-shoot workflow would enhance their application as diagnostic tools in food fraud control. Here, triple stage mass spectrometry (MS(3)) demonstrated excellent analyte selectivity capability even when incomplete chromatographic separation was performed. Method validation was performed at six concentration levels of 100, 200, 400, 800, 1200 and 1600ngg(-1). Spiking experiments were examined at three concentration levels of 200, 400, and 1200ngg(-1) in individual egg white and egg yolk, measured over 2days. MS(3) enabled ion chromatograms with zero-background interference to be made in egg extracts. MS(3) eliminated severe over recovery (p<0.05) observed in all fortified samples, a challenge that MRM-transition could not address in a single step. Matrix-matched calibrants were needed to compensate for over recovery observed under MRM-transition mode. PMID:24360442

  13. A procedure for accurate calibration of the orientation of the three sensors in a vector magnetometer. [at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Mcpherron, R. L.

    1977-01-01

    Procedures are described for the calibration of a vector magnetometer of high absolute accuracy. It is assumed that the calibration will be performed in the magnetic test facility of Goddard Space Flight Center (GSFC). The first main section of the report describes the test equipment and facility calibrations required. The second presents procedures for calibrating individual sensors. The third discusses the calibration of the sensor assembly. In a final section recommendations are made to GSFC for modification of the test facility required to carry out the calibration procedures.

  14. Nuclear medicine practices in the 1950s through the mid-1970s and occupational radiation doses to technologists from diagnostic radioisotope procedures.

    PubMed

    Drozdovitch, Vladimir; Brill, Aaron B; Mettler, Fred A; Beckner, William M; Goldsmith, Stanley J; Gross, Milton D; Hays, Marguerite T; Kirchner, Peter T; Langan, James K; Reba, Richard C; Smith, Gary T; Bouville, André; Linet, Martha S; Melo, Dunstana R; Lee, Choonsik; Simon, Steven L

    2014-10-01

    Data on occupational radiation exposure from nuclear medicine procedures for the time period of the 1950s through the 1970s is important for retrospective health risk studies of medical personnel who conducted those activities. However, limited information is available on occupational exposure received by physicians and technologists who performed nuclear medicine procedures during those years. To better understand and characterize historical radiation exposures to technologists, the authors collected information on nuclear medicine practices in the 1950s, 1960s, and 1970s. To collect historical data needed to reconstruct doses to technologists, a focus group interview was held with experts who began using radioisotopes in medicine in the 1950s and the 1960s. Typical protocols and descriptions of clinical practices of diagnostic radioisotope procedures were defined by the focus group and were used to estimate occupational doses received by personnel, per nuclear medicine procedure, conducted in the 1950s to 1960s using radiopharmaceuticals available at that time. The radionuclide activities in the organs of the reference patient were calculated using the biokinetic models described in ICRP Publication 53. Air kerma rates as a function of distance from a reference patient were calculated by Monte Carlo radiation transport calculations using a hybrid computational phantom. Estimates of occupational doses to nuclear medicine technologists per procedure were found to vary from less than 0.01 μSv (thyroid scan with 1.85 MBq of administered I-iodide) to 0.4 μSv (brain scan with 26 MBq of Hg-chlormerodin). Occupational doses for the same diagnostic procedures starting in the mid-1960s but using Tc were also estimated. The doses estimated in this study show that the introduction of Tc resulted in an increase in occupational doses per procedure. PMID:25162420

  15. NUCLEAR MEDICINE PRACTICES IN THE 1950s THROUGH THE mid-1970s AND OCCUPATIONAL RADIATION DOSES TO TECHNOLOGISTS FROM DIAGNOSTIC RADIOISOTOPE PROCEDURES

    PubMed Central

    Drozdovitch, Vladimir; Brill, Aaron B.; Mettler, Fred A.; Beckner, William M.; Goldsmith, Stanley J.; Gross, Milton D.; Hays, Marguerite T.; Kirchner, Peter T.; Langan, James K.; Reba, Richard C.; Smith, Gary T.; Bouville, André; Linet, Martha S.; Melo, Dunstana R.; Lee, Choonsik; Simon, Steven L.

    2014-01-01

    Data on occupational radiation exposure from nuclear medicine procedures for the time period of the 1950s through the 1970s is important for retrospective health risk studies of medical personnel who conducted those activities. However, limited information is available on occupational exposure received by physicians and technologists who performed nuclear medicine procedures during those years. To better understand and characterize historical radiation exposures to technologists, we collected information on nuclear medicine practices in the 1950s, 1960s, and 1970s. To collect historical data needed to reconstruct doses to technologists, a focus group interview was held with experts who began using radioisotopes in medicine in the 1950s and the 1960s. Typical protocols and descriptions of clinical practices of diagnostic radioisotope procedures were defined by the focus group and were used to estimate occupational doses received by personnel, per nuclear medicine procedure, conducted in the 1950s-1960s using radiopharmaceuticals available at that time. The radionuclide activities in the organs of the reference patient were calculated using the biokinetic models described in ICRP Publication 53. Air kerma rates as a function of distance from a reference patient were calculated by Monte Carlo radiation transport calculations using a hybrid computational phantom. Estimates of occupational doses to nuclear medicine technologists per procedure were found to vary from less than 0.01 μSv (thyroid scan with 1.85 MBq of administered 131I-iodide) to 0.4 μSv (brain scan with 26 MBq of 203Hg-chlormerodin). Occupational doses for the same diagnostic procedures starting in the mid-1960s but using 99mTc were also estimated. The doses estimated in this study show that the introduction of 99mTc resulted in an increase in occupational doses per procedure. PMID:25162420

  16. Degree of Vertical Integration Between the Undergraduate Program and Clinical Internship with Respect to Lumbopelvic Diagnostic and Therapeutic Procedures Taught at the Canadian Memorial Chiropractic College

    PubMed Central

    Vermet, Shannon; McGinnis, Karen; Boodham, Melissa; Gleberzon, Brian J.

    2010-01-01

    Purpose: The objective of this study was to determine to what extent the diagnostic and therapeutic procedures taught in the undergraduate program used for patients with lumbopelvic conditions are expected to be utilized by students during their clinical internship program at Canadian Memorial Chiropractic College or are being used by the clinical faculty. Methods: A confidential survey was distributed to clinical faculty at the college. It consisted of a list of diagnostic and therapeutic procedures used for lumbopelvic conditions taught at that college. Clinicians were asked to indicate the frequency with which they performed or they required students to perform each item. Results: Seventeen of 23 clinicians responded. The following procedures were most likely required to be performed by clinicians: posture; ranges of motion; lower limb sensory, motor, and reflex testing; and core orthopedic tests. The following were less likely to be required to be performed: Waddell testing, Schober's test, Gillet tests, and abdominal palpation. Students were expected to perform (or clinicians performed) most of the mobilization (in particular, iliocostal, iliotransverse, and iliofemoral) and spinal manipulative therapies (in particular, the procedures referred to as the lumbar roll, lumbar pull/hook, and upper sacroiliac) taught at the college. Conclusion: This study suggests that there was considerable, but not complete, vertical integration between the undergraduate and clinical education program at this college. PMID:20480014

  17. Impact of the phlebotomy training based on CLSI/NCCLS H03-A6 - procedures for the collection of diagnostic blood specimens by venipuncture.

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Introduction: The activities involving phlebotomy, a critical task for obtaining diagnostic blood samples, are poorly studied as regards the major sources of errors and the procedures related to laboratory quality control. The aim of this study was to verify the compliance with CLSI documents of clinical laboratories from South America and to assess whether teaching phlebotomists to follow the exact procedure for blood collection by venipuncture from CLSI/NCCLS H03-A6 - Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture might improve the quality of the process. Materials and methods: A survey was sent by mail to 3674 laboratories from South America to verify the use of CLSI documents. Thirty skilled phlebotomists were trained with the CLSI H03-A6 document to perform venipuncture procedures for a period of 20 consecutive working days. The overall performances of the phlebotomists were further compared before and after the training program. Results: 2622 from 2781 laboratories that did answer our survey used CLSI documents to standardize their procedures and process. The phlebotomists’ training for 20 days before our evaluation completely eliminated non-conformity procedures for: i) incorrect friction of the forearm, during the cleaning of the venipuncture site to ease vein location; ii) incorrect sequence of vacuum tubes collection; and iii) inadequate mixing of the blood in primary vacuum tubes containing anticoagulants or clot activators. Unfortunately the CLSI H03-A6 document does not caution against both unsuitable tourniquet application time (i.e., for more than one minute) and inappropriate request to clench the fist repeatedly. These inadequate procedures were observed for all phlebotomists. Conclusion: We showed that strict observance of the CLSI H03-A6 document can remarkably improve quality, although the various steps for collecting diagnostic blood specimens are not a gold standard, since they may still permit errors. Tourniquet

  18. Frequency Scale Factors for Some Double-Hybrid Density Functional Theory Procedures: Accurate Thermochemical Components for High-Level Composite Protocols.

    PubMed

    Chan, Bun; Radom, Leo

    2016-08-01

    In the present study, we have obtained geometries and frequency scale factors for a number of double-hybrid density functional theory (DH-DFT) procedures. We have evaluated their performance for obtaining thermochemical quantities [zero-point vibrational energies (ZPVE) and thermal corrections for 298 K enthalpies (ΔH298) and 298 K entropies (S298)] to be used within high-level composite protocols (using the W2X procedure as a probe). We find that, in comparison with the previously prescribed protocol for optimization and frequency calculations (B3-LYP/cc-pVTZ+d), the use of contemporary DH-DFT methods such as DuT-D3 and DSD-type procedures leads to a slight overall improved performance compared with B3-LYP. A major strength of this approach, however, lies in the better robustness of the DH-DFT methods in that the largest deviations are notably smaller than those for B3-LYP. In general, the specific choices of the DH-DFT procedure and the associated basis set do not drastically change the performance. Nonetheless, we find that the DSD-PBE-P86/aug'-cc-pVTZ+d combination has a very slight edge over the others that we have examined, and we recommend its general use for geometry optimization and vibrational frequency calculations, in particular within high-level composite methods such as the higher-level members of the WnX series of protocols. The scale factors determined for DSD-PBE-P86/aug'-cc-pVTZ+d are 0.9830 (ZPVE), 0.9876 (ΔH298), and 0.9923 (S298). PMID:27471908

  19. Interrelation of Evaluation and Self-Evaluation in the Diagnostic Procedures to Assess Teachers' Readiness for Innovation

    ERIC Educational Resources Information Center

    Tyunnikov, Yurii S.

    2016-01-01

    The paper solves the problem of the relationship of external diagnosis and self-diagnosis of readiness of teachers to innovative activity. It highlights major disadvantages of measurement tools that are used to this process. The author demonstrates an alternative approach to harmonizing the diagnosis, based on a modular diagnostic model, general…

  20. Reliability and Validity of a Procedure To Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    Preliminary psychometric data assessing the reliability and validity of a method used to measure the diagnostic reasoning and problem-solving skills of predoctoral students in orthodontia are described. The measurement approach consisted of sets of patient demographic data and dental photos and x-rays, accompanied by a set of 33 multiple-choice…

  1. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  2. General design and implementation procedure for sensor-based electrical diagnostic systems for mining machinery. Report of investigation/1993

    SciTech Connect

    Kohler, J.L.; Sottile, J.

    1993-01-01

    The objective of the research was to develop a sensor-based diagnostic system for generic application to mining machinery, using a KBES implementation. The efficacy of the system was to be evaluated by constructing a prototype and installing it on an actual mining machine. A Joy 14CM continuous mining machine was to be used for the prototype development.

  3. Changes in Racial Differences in Use of Medical Procedures and Diagnostic Tests Among Elderly Persons: 1986–1997

    PubMed Central

    Escarce, José J.; McGuire, Thomas G.

    2004-01-01

    Objectives. We used 1997 Medicare data to replicate an earlier study that used data from 1986 to examine racial differences in usage of specific medical procedures or tests among elderly persons. Methods. We used 1997 physician claims data to obtain a random sample of 5% of Medicare beneficiaries aged 65 years and older. We used this sample to study 30 procedures and tests that were analyzed in the 1986 study, as well as several new procedures that became more widely used in the early 1990s. Results. Racial differences remain in the rates of use of these procedures; in general, Blacks have lower rates of use than do Whites. Between 1986 and 1997, the ratio of White to Black use moved in favor of Blacks for all but 4 of the established procedures studied. Conclusions. The White–Black gap in health care use under Medicare is narrowing. PMID:15451752

  4. An update on radiation absorbed dose to patients from diagnostic nuclear medicine procedures in Tehran: A study on four academic centers

    PubMed Central

    Motazedian, Motahareh; Tabeie, F; Vatankhah, P; Shafiei, B; Amoui, M; Atefi, M; Ansari, M; Asli, I Neshandar

    2016-01-01

    Purpose: Use of radiopharmaceuticals for diagnostic nuclear medicine procedures is one of the main sources of radiation exposure. We performed this study with respect to the rapid growth in nuclear medicine in Iran and lack of updated statistics. Materials and Methods: The data were obtained for all active Nuclear Medicine Centers affiliated to Shahid Beheshti University of Medical Sciences during 2009 and 2010. Results: The most frequently performed procedures were bone (30.16%), cardiac (28.96%), renal (17.97%), and thyroid (7.93%) scans. There was a significant decrease in the number of thyroid scintigraphies with 131I and 99mTc-sulfur colloid liver/spleen scans and tremendous increase in the frequencies of cardiac and bone scintigraphies compared to one decade ago. Conclusion: Compared to previous studies, there were striking changes in trends of diagnostic nuclear medicine procedures in Tehran. This field is still evolving in the country, and this trend will further change with the introduction of positron emission tomography scanners in future. PMID:27095860

  5. Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures: Update 2016.

    PubMed

    Coté, Charles J; Wilson, Stephen

    2016-01-01

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical/dental supervision, careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications, appropriate fasting for elective procedures and a balance between the depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure, a focused airway examination for large (kissing) tonsils or anatomic airway abnormalities that might increase the potential for airway obstruction, a clear understanding of the medication's pharmacokinetic and pharmacodynamic effects and drug interactions, appropriate training and skills in airway management to allow rescue of the patient, age- and size-appropriate equipment for airway management and venous access, appropriate medications and reversal agents, sufficient numbers of staff to both carry out the procedure and monitor the patient, appropriate physiologic monitoring during and after the procedure, a properly equipped and staffed recovery area, recovery to the presedation level of consciousness before discharge from medical/dental supervision, and appropriate discharge instructions. This report was developed through a collaborative effort of the American Academy of Pediatrics and the American Academy of Pediatric Dentistry to offer pediatric providers updated information and guidance in delivering safe sedation to children. PMID:27557912

  6. Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures: Update 2016.

    PubMed

    Coté, Charles J; Wilson, Stephen

    2016-07-01

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical/dental supervision, careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications, appropriate fasting for elective procedures and a balance between the depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure, a focused airway examination for large (kissing) tonsils or anatomic airway abnormalities that might increase the potential for airway obstruction, a clear understanding of the medication's pharmacokinetic and pharmacodynamic effects and drug interactions, appropriate training and skills in airway management to allow rescue of the patient, age- and size-appropriate equipment for airway management and venous access, appropriate medications and reversal agents, sufficient numbers of staff to both carry out the procedure and monitor the patient, appropriate physiologic monitoring during and after the procedure, a properly equipped and staffed recovery area, recovery to the presedation level of consciousness before discharge from medical/dental supervision, and appropriate discharge instructions. This report was developed through a collaborative effort of the American Academy of Pediatrics and the American Academy of Pediatric Dentistry to offer pediatric providers updated information and guidance in delivering safe sedation to children. PMID:27354454

  7. Guideline for monitoring and management of pediatric patients during and after sedation for diagnostic and therapeutic procedures.

    PubMed

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical supervision, careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications, appropriate fasting for elective procedures and a balance between depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure, a focused airway examination for large tonsils or anatomic airway abnormalities that might increase the potential for airway obstruction, a clear understanding of the pharmacokinetic and pharmacodynamic effects of the medications used for sedation as well as an appreciation for drug interactions, appropriate training and skills in airway management to allow rescue of the patient, age- and size-appropriate equipment for airway management and venous access, appropriate medications and reversal agents, sufficient numbers of people to both carry out the procedure and monitor the patient, appropriate physiologic monitoring during and after the procedure, a properly equipped and staffed recovery area, recovery to presedation level of consciousness before discharge from medical supervision, and appropriate discharge instructions. PMID:19216414

  8. Entonox® inhalation to reduce pain in common diagnostic and therapeutic outpatient urological procedures: a review of the evidence

    PubMed Central

    Young, A; Ismail, M; Papatsoris, AG; Barua, JM; Calleary, JG; Masood, J

    2012-01-01

    INTRODUCTION Entonox® (50% nitrous oxide and 50% oxygen; BOC Healthcare, Manchester, UK) is an analgesic and anxiolytic agent that is used to successfully reduce pain and anxiety during dental, paediatric and emergency department procedures. In this article we review the application and efficacy of Entonox® in painful local anaesthesia urological procedures by performing a systematic review of the literature. METHODS A MEDLINE® search was performed using the terms ‘nitrous oxide’, ‘Entonox’, ‘prostate biopsy’, ‘flexible cystoscopy’ and ‘extracorporeal shock wave lithotripsy’. English language publications of randomised studies were identified and reviewed. RESULTS The search yielded five randomised studies that investigated the clinical efficacy of Entonox® as an analgesic for day case urological procedures. Three randomised controlled trials (RCTs) investigated Entonox® in transrectal ultrasonography guided prostate biopsy. All three reported significant reductions in pain score in the Entonox® versus control groups. One RCT reported significant reduction in pain during male flexible cystoscopy in the Entonox® group compared with the control group. One RCT, which examined the use of Entonox® during extracorporeal shock wave lithotripsy, found its use significantly decreased the pain score compared with the control group and this was comparable to intravenous pethidine. CONCLUSIONS Evidence from varied adult and paediatric procedures has shown Entonox® to be an effective, safe and patient acceptable form of analgesia. All published studies of its use in urological day case procedures have found it to significantly reduce procedural pain. There is huge potential to use this cheap, safe, effective analgesic in our current practice. PMID:22524905

  9. Puumala Hantavirus-Induced Hemorrhagic Fever with Renal Syndrome Must Be Considered across the Borders of Nephrology to Avoid Unnecessary Diagnostic Procedures

    PubMed Central

    Kitterer, Daniel; Segerer, Stephan; Alscher, M. Dominik; Braun, Niko; Latus, Joerg

    2015-01-01

    Background Nephropathia epidemica (NE), a milder form of hemorrhagic fever with renal syndrome, is caused by Puumala virus and is characterized by acute kidney injury and thrombocytopenia. Methods A cross-sectional prospective survey of 456 adult patients with serologically confirmed NE was performed. Results Of the 456 investigated patients, 335 had received inpatient treatment. At time of admission to hospital, 72% of the patients had still an AKI and thrombocytopenia was present in 64% of the patients. The 335 patients were treated in 29 different hospitals and 6 of which had nephrology departments. 10 out of 335 patients received treatment in university hospitals and 63% of patients admitted themselves to hospital. Initially, the patients were admitted to 12 different clinical departments (29% of the patients were referred to a nephrology department) and during the course of the disease, 8% of the patients were transferred to another department in the same hospital and 3% were transferred to a nephrology department at another hospital. Regarding diagnostic procedures, in 28% of the inpatients computed tomography to exclude pulmonary embolism or due to severe gastrointestinal symptoms, lumbar puncture to exclude meningitis, magnetic resonance tomography of the brain owing to suspected stroke because of visual disorders, gastroscopy, or colonoscopy due to gastrointestinal symptoms was performed at time of admission to hospital. Conclusions NE must be considered by physicians across the borders of nephrology to avoid unnecessary diagnostic procedures especially in areas where NE is endemic. PMID:26650941

  10. Characteristics of gastrointestinal stromal tumours, diagnostic procedure and therapeutic management and main directions of nursing practice in gastrointestinal stromal tumours

    PubMed Central

    Głuszek, Stanisław; Kozieł, Dorota

    2014-01-01

    Gastrointestinal stromal tumours (GIST) constitute a separate group of mesenchymal neoplasms of the gastrointestinal tract. They have been commonly recognized for a few years, they have created a new problem in medical practice. GIST are more often centred in the stomach. They equally affect female and male patients and occur mainly in patients older than 50 years of age. The clinical picture of the tumour is non-specific. Radical surgical treatment and molecularly targeted therapy with tyrosine kinase inhibitors are used in GIST treatment. Nursing practice with reference to GIST danger is connected with biopsychosocial interventions of perioperative, oncological and palliative procedures and involves the area of health education mainly oriented towards shaping preventive procedures which favour early disease detection and support therapy and recovery. PMID:25784835

  11. Recorded gonorrhoea rates in Denmark, 1900–2010: the impact of clinical testing activity and laboratory diagnostic procedures

    PubMed Central

    Lind, Inga; Hoffmann, Steen

    2015-01-01

    Objectives Assessment of the relations between recorded gonorrhoea rates and clinical testing activity and disposable diagnostic tests. Methods In Denmark, two sources of information on the epidemiology of gonorrhoea are available: (1) a mandatory clinical notification system (since 1867) comprising summary information about geographic distribution, season, age group and gender; in 1994, more detailed anonymous individualised epidemiological information was included; (2) a voluntary countrywide laboratory surveillance system for culture-confirmed cases (since 1957) comprising information about patient's age and gender, infected anatomical sites and medical setting attended. Results Both surveillance systems showed marked simultaneous changes in gonorrhoea rates, although periodically considerable under-reporting or under-diagnosing was demonstrated. The annual incidence of notified cases peaked in 1919 (474/100 000), in 1944 (583/100 000) and in 1972 (344/100 000). Since 1995, the incidence has been at a low endemic level (1.5–10/100 000) and the total male/female incidence ratios were from 3 to 7 times higher than previously recorded. Among approximately 2 million persons tested during 1974–1988 78 213 men and 63 143 women with culture-confirmed gonorrhoea were identified. During this period, pharyngeal sampling was performed in 36% of men and 25% of women with gonorrhoea; pharyngeal gonorrhoea was found in 10% and 16%, respectively; 40% and 30% of these patients had no concomitant urogenital gonorrhoea. Among men with gonorrhoea, 34% were sampled from the rectum; 9% had rectal gonorrhoea, among whom the rectum was the only infected site in 67%. Conclusions Crucial factors for case finding are clinical sampling tradition and appropriate laboratory diagnostic facilities. When case finding is insufficient, a reservoir of asymptomatic rectal or pharyngeal gonorrhoea remains unrecognised. PMID:26621510

  12. Follow-up study of persons who had iodine-131 and other diagnostic procedures during childhood and adolescence

    SciTech Connect

    Hamilton, P.M.; Chiacchierini, R.P.; Kaczmarek, R.G.

    1989-08-01

    A prospective study of 3,503 children and adolescents who received diagnostic doses of iodine-131 was conducted to evaluate the risk of radiation-induced thyroid neoplasia. The exposed group was followed for a total of 93,442 person-years. Thyroid doses received by the exposed group ranged from less than 10 rads to slightly more than 2,000 rads. The majority received less than 100 rads. A group of 2,594 children and adolescents who were not exposed to radioactive iodine comprised the control group for the study. Members of the control group were followed for a total of 66,797 person-years. An elevated risk of malignant thyroid tumors was observed in the exposed group. An increased risk of benign thyroid conditions was also noted in the exposed group. The results described above failed to fulfill the requirements for statistical significance because of the small number of cases but are suggestive of a radiation effect.

  13. NASPE expert consensus document: use of i.v. (conscious) sedation/analgesia by nonanesthesia personnel in patients undergoing arrhythmia specific diagnostic, therapeutic, and surgical procedures.

    PubMed

    Bubien, R S; Fisher, J D; Gentzel, J A; Murphy, E K; Irwin, M E; Shea, J B; Dick, M; Ching, E; Wilkoff, B L; Benditt, D G

    1998-02-01

    Use of IV (Conscious) Sedation/Analgesia by Nonanesthesia Personnel in Patients Undergoing Arrhythmia Specific Diagnostic, Therapeutic, and Surgical Procedures. This article is intended to inform practitioners, payers, and other interested parties of the opinion of the North American Society of Pacing and Electrophysiology (NASPE) concerning evolving areas of clinical practice or technologies or both, that are widely available or are new to the practice community. Expert consensus documents are so designated because the evidence base and experience with the technology or clinical practice are not yet sufficiently well developed, or rigorously controlled trials are not yet available that would support a more definitive statement. This article has been endorsed by the American College of Cardiology, October 1997. PMID:9507538

  14. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    SciTech Connect

    D'Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  15. [Diagnostic and therapeutic procedure for two popular but quite distinct adverse reactions to food - fructose malabsorption and histamine intolerance].

    PubMed

    Reese, I

    2012-04-01

    Claiming to suffer from adverse food reactions is popular. In contrast to the classical food allergy, there are some pathomechanisms which are evidently dose-dependent. Thus the procedure in diagnosis and therapy must undoubtedly differ from the practice when food allergy is suspected or proven. Nevertheless many patients suffering from dose-dependent adverse reactions to food are given strict elimination diets, which is neither necessary nor helpful and decreases their quality of life broadly. This holds especially true for fructose malabsorption and histamine intolerance. For the latter, the term adverse reaction to ingested histamine is preferred, because histamine intolerance implies that symptoms are caused entirely by an enzyme defect. Why this is not very likely to be the only reason is discussed in this article. Both adverse reactions require an individual approach especially with regard to nutrition therapy. Therefore the task of diagnosis should be to establish an individual profile of tolerated and not tolerated foods taking into account that tolerance can greatly vary by meal composition, frequency and individual triggering factors. In view of this, therapeutic recommendations should not be based on the absolute quantities of the eliciting substance to be eliminated but on a feasible transfer into daily life. Thereby food restriction can be minimized and a high quality of life will be maintained. PMID:22477662

  16. Diagnostic Performance of Endoscopic and Microscopic Procedures for Identifying Different Middle Ear Structures and Remaining Disease in Patients with Chronic Otitis Media: A Prospective Cohort Study

    PubMed Central

    Farahani, Farhad; Shariatpanahi, Elnaz; Jahanshahi, Javane; Poorolajal, Jalal

    2015-01-01

    Background The diagnostic performance of endoscopic and microscopic procedures for detecting diseases of the middle ear in patients with chronic otitis media (COM) has rarely been investigated. This study was conducted to compare the performance of these procedures for identifying middle ear structures and their associated diseases in COM patients. Methods In this prospective cohort study, 58 patients with chronic COM, who were candidates for tympanoplasty with or without a mastoidectomy, were enrolled. Before the surgical intervention, the middle ear was examined via an operating microscope and then through an endoscope to identify the middle ear structures as well as diseases associated with the middle ear. Results The patients were 15 years of age or older. The anatomical parts of the middle ear – the epitympanic, posterior mesotympanic, and hypotympanic structures – were more visible through an endoscope than through a microscope. In addition, the various segments of the mesotympanum, oval window, round window, and Eustachian tube were more visible via endoscopy. The post-operative endoscopic reevaluation of the middle ear revealed that a cholesteatoma had remained in four of 13 patients after surgery. Conclusion According to the results of this study, in cases in which there is poor visibility with the operating microscope or the surgeon suspects remaining disease within the middle ear, endoscopy could be utilized to improve the evaluation of more hidden middle ear pits and structures, particularly if there is a potentially recrudescent pathology. PMID:26167935

  17. Fetal infection from rubeovirus or cytomegalovirus: correlation among maternal serological profiles, invasive diagnostic procedures, and long-term follow-up.

    PubMed

    Noia, G; Masini, L; De Santis, M; Scavo, M; Pomini, F; Grillo, R; Cattani, P; Ranno, O; Caruso, A; Mancuso, S

    1998-01-01

    Different variables influence the possibility that maternal viral infection may be transmitted to the fetus, although not all fetal infections result in fetal "illness" with consequent fetopathy. As concerns the fetus, prenatal diagnosis includes invasive techniques necessary for fetal tissue sampling. These techniques carry some risks. The fetal infectious risk, as determined by maternal clinico-serological profile and according to sonographic investigation, always should be weighed against the risks and benefits of invasive diagnostic procedures. The present study re-elaborates the criteria necessary for defining fetal risk as related to the maternal serological profile. In the 26 mothers with rubeola infection, the incidence of fetal mortality was 7.7%. Fetal prognosis worsens with the precocity of eruption. In these cases the esantema is the most reliable prognostic element as an indication to perform the invasive procedure. In the 15 patients with cytomegalovirus infection, no fetal or postnatal losses occurred. Morbidity occurred in 13.3% of cases, and the two ill fetuses were classified in the same risk group. In this group of patients, the maternal serological profile is a significant predictor of fetal morbidity. PMID:9502669

  18. NNLOPS accurate associated HW production

    NASA Astrophysics Data System (ADS)

    Astill, William; Bizon, Wojciech; Re, Emanuele; Zanderighi, Giulia

    2016-06-01

    We present a next-to-next-to-leading order accurate description of associated HW production consistently matched to a parton shower. The method is based on reweighting events obtained with the HW plus one jet NLO accurate calculation implemented in POWHEG, extended with the MiNLO procedure, to reproduce NNLO accurate Born distributions. Since the Born kinematics is more complex than the cases treated before, we use a parametrization of the Collins-Soper angles to reduce the number of variables required for the reweighting. We present phenomenological results at 13 TeV, with cuts suggested by the Higgs Cross section Working Group.

  19. Neurological Diagnostic Tests and Procedures

    MedlinePlus

    ... than an hour. Magnetic resonance imaging (MRI) uses computer-generated radio waves and a powerful magnetic field ... signal at different angles within the body. A computer processes this resonance into either a three-dimensional ...

  20. Population radiation dose from diagnostic nuclear medicine procedures in the Tehran population in 1999-2003: striking changes in only one decade.

    PubMed

    Tabeie, Faraj; Mohammadi, Hooshang; Asli, Isa Neshandar

    2013-02-01

    Use of unsealed radiopharmaceuticals in Iran's nuclear medicine centers has expanded rapidly in the last decade. As part of a nationwide survey, this study was undertaken to estimate the radiation risk due to the diagnostic nuclear medicine procedures performed in Tehran in 1999-2003. During the five years of the study, the data of 101,540 yearly examinations of diagnostic nuclear medicine were obtained for 34 (out of 40) active nuclear medicine centers in Tehran. The patients studied were aged 1 y, 5 y, 10 y, 15 y, and adults (>15 y). Compared to an earlier investigation in 1989 (which was published in 1995), striking changes were found to be occurring in the trends of nuclear medicine in Tehran in a matter of a decade. The frequency of cardiac examinations increased from less than 1% in 1989 to 43.2% (mean of 5 y) in 2003; thyroid examinations, with the relative frequency of higher than 80% in 1989, decreased to 26.7% in the current investigation (averaged for 2001); and the number of overall examinations per 1,000 population of Tehran increased from 1.9 in 1989 to 8.8 in this study (about fourfold). The decrease in relative frequency of thyroid examinations could be attributed to the lower referral policy (mainly by specialists), decreased incidence of goiter due to implementation of programs for iodine enrichment diets, introduction of fine needle aspiration (FNA), and sonography techniques for diagnosis of thyroid disease. The large increase in relative frequency of cardiac examinations could be due to the increase in the number of single photon emission computerized tomography (SPECT) systems in recent years as compared to 1989 in Tehran. The collective effective dose increased from 400 (person-Sv) in 1999 to 529 (person-Sv) in 2003, and the effective dose per capita increased from 34.80 μSv in 1999 to 44.06 μSv in 2003 (average, 35.60 μSv). PMID:23274814

  1. Diagnostic imaging.

    PubMed

    Morris, Peter; Perkins, Alan

    2012-04-21

    Physical techniques have always had a key role in medicine, and the second half of the 20th century in particular saw a revolution in medical diagnostic techniques with the development of key imaging instruments: x-ray imaging and emission tomography (nuclear imaging and PET), MRI, and ultrasound. These techniques use the full width of the electromagnetic spectrum, from gamma rays to radio waves, and sound. In most cases, the development of a medical imaging device was opportunistic; many scientists in physics laboratories were experimenting with simple x-ray images within the first year of the discovery of such rays, the development of the cyclotron and later nuclear reactors created the opportunity for nuclear medicine, and one of the co-inventors of MRI was initially attempting to develop an alternative to x-ray diffraction for the analysis of crystal structures. What all these techniques have in common is the brilliant insight of a few pioneering physical scientists and engineers who had the tenacity to develop their inventions, followed by a series of technical innovations that enabled the full diagnostic potential of these instruments to be realised. In this report, we focus on the key part played by these scientists and engineers and the new imaging instruments and diagnostic procedures that they developed. By bringing the key developments and applications together we hope to show the true legacy of physics and engineering in diagnostic medicine. PMID:22516558

  2. [Have Case Loads of Radical Surgery for Prostate Cancer Been Concentrated in Hospitals with Robotic Equipment ?--Analyses with Questionnaire Survey and Diagnostic Procedure Combination (DPC) Data].

    PubMed

    Tsukamoto, Taiji; Tanaka, Shigeru

    2016-04-01

    We investigated whether installation of robot-assisted surgical equipment in hospitals resulted in concentration of the case loads of radical prostatectomy. We selected 11 areas with populations of around 1 million or more where there were one or more hospitals with robotic equipment and 4 or more without it. In addition, annual changes of case loads for prostatectomy over 4 years from 2010 to 2013 were clearly determined in these areas. The case loads were determined based on the results of a questionnaire survey for the hospitals with robots and on the Diagnostic Procedures Combination data provided by the Ministry of Health, Labor and Wealth for those without such equipment. The concentration of the case loads was principally defined as when hospitals with robots had more predominant proportion of cases than those without them in the comparison between case loads prior to instillation of robots (or in the initial year of the study) and those in the final years. The 11 selected areas included 44 hospitals with robots and 156 without them. Concentration of case loads was found in 5 areas. In 4 areas, installation of robots did not have a specific relation to the distribution pattern s of case loads in hospitals with or without the equipment. The remaining 2 areas tended to have a weak but not definite concentration of case loads. In the areas in which installation did not influence case loads the further analysis revealed that their case loads had already been concentrated in the initial year (2010) of the study. Although the current results were found in a single department of the hospital, robotic installation may result in concentration of prostatectomy case loads for such hospitals in some areas. The current results are intriguing when we consider the future roles of acute care hospitals and beds in our country where the number of aged patients having chronic diseases will increase. In conclusion, installation of robotic equipment may result in concentration

  3. Diagnostics of bearings in presence of strong operating conditions non-stationarity—A procedure of load-dependent features processing with application to wind turbine bearings

    NASA Astrophysics Data System (ADS)

    Zimroz, Radoslaw; Bartelmus, Walter; Barszcz, Tomasz; Urbanek, Jacek

    2014-05-01

    Condition monitoring of bearings used in Wind Turbines (WT) is an important issue. In general, bearings diagnostics is a well recognized field of research; however, it is not the case for machines operating under non-stationary load. In the case of varying load/speed, vibration signal generated by rolling element bearings is affected by operation factors, and makes the diagnosis relatively difficult. These difficulties come from the variation of vibration-based diagnostic features caused mostly by load/speed variation (operation factors), low energy of sought-after features, and low signal-to-noise levels. Analysis of the signal from the main bearing is even more difficult due to a very low rotational speed of the main shaft. In the paper, a novel diagnostic approach is proposed for bearings used in wind turbines. As an input data we use parameters obtained from commercial diagnostic system (peak-to-peak and root mean square (RMS) of vibration acceleration, and generator power that is related to the operating conditions). The received data cover the period of several months.

  4. Diagnostics for pulmonary tuberculosis.

    PubMed

    Cudahy, Patrick; Shenoi, Sheela V

    2016-04-01

    Tuberculosis (TB) remains a leading cause of human suffering and mortality despite decades of effective treatment being available. Accurate and timely diagnosis remains an unmet goal. The HIV epidemic has also led to new challenges in the diagnosis of TB. Several new developments in TB diagnostics have the potential to positively influence the global campaign against TB. We aim to review the performance of both established as well as new diagnostics for pulmonary TB in adults, and discuss the ongoing challenges. PMID:27005271

  5. Diagnostics for pulmonary tuberculosis

    PubMed Central

    Cudahy, Patrick

    2016-01-01

    Tuberculosis (TB) remains a leading cause of human suffering and mortality despite decades of effective treatment being available. Accurate and timely diagnosis remains an unmet goal. The HIV epidemic has also led to new challenges in the diagnosis of TB. Several new developments in TB diagnostics have the potential to positively influence the global campaign against TB. We aim to review the performance of both established as well as new diagnostics for pulmonary TB in adults, and discuss the ongoing challenges. PMID:27005271

  6. Frequency of use of diagnostic and manual therapeutic procedures of the spine taught at the Canadian Memorial Chiropractic College: A preliminary survey of Ontario chiropractors. Part 1 – practice characteristics and demographic profiles

    PubMed Central

    Gleberzon, Brian; Stuber, Kent

    2013-01-01

    Background: Students learn a plethora of physical examination and manual therapy procedures over the course of their chiropractic education. However, it is uncertain to what extent they continue to use these procedures in practice after graduation. Objective: The purpose of this study was to determine which diagnostic and therapeutic procedures of the spine are most commonly utilized by chiropractors practicing in Ontario. In Part 1 of this study (presented here), the demographics and practice patterns of the respondents are presented. Part 2 of this study will present the results of the utilization rates of diagnostic and therapeutic procedures used by respondents. Methods: The study consisted of a paper-based survey that was sent to 500 pseudo-randomly selected Ontario chiropractors who responded confidentially. Survey questions inquired into demographic and practice style characteristics. Results: There were 108 respondents to the survey, giving a response rate of 22.4%. Many chiropractors self-identified themselves with more than one practice style characteristic such as 72.4% of the self-described pain-based chiropractors who also described themselves as evidence-based, compared with 51.9% of subluxation-based chiropractors who also described themselves as evidence-based. Diversified technique was the most commonly employed technique used by 90.7% of respondents, followed by trigger point therapy indicated by 57.4% of respondents. Conclusions: Despite a low response rate, respondents reported practice characteristics in this study that were similar to practice characteristics previously published, particularly in terms of professional demographics and techniques employed. While Diversified was the most commonly used technique, respondents reported higher levels of use of proprietary soft tissue techniques systems and upper cervical techniques than have been previously reported. PMID:23482716

  7. Accurate and Accidental Empathy.

    ERIC Educational Resources Information Center

    Chandler, Michael

    The author offers two controversial criticisms of what are rapidly becoming standard assessment procedures for the measurement of empathic skill. First, he asserts that assessment procedures which attend exclusively to the accuracy with which subjects are able to characterize other people's feelings provide little or no useful information about…

  8. Grading More Accurately

    ERIC Educational Resources Information Center

    Rom, Mark Carl

    2011-01-01

    Grades matter. College grading systems, however, are often ad hoc and prone to mistakes. This essay focuses on one factor that contributes to high-quality grading systems: grading accuracy (or "efficiency"). I proceed in several steps. First, I discuss the elements of "efficient" (i.e., accurate) grading. Next, I present analytical results…

  9. Accurate monotone cubic interpolation

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1991-01-01

    Monotone piecewise cubic interpolants are simple and effective. They are generally third-order accurate, except near strict local extrema where accuracy degenerates to second-order due to the monotonicity constraint. Algorithms for piecewise cubic interpolants, which preserve monotonicity as well as uniform third and fourth-order accuracy are presented. The gain of accuracy is obtained by relaxing the monotonicity constraint in a geometric framework in which the median function plays a crucial role.

  10. Accurate Finite Difference Algorithms

    NASA Technical Reports Server (NTRS)

    Goodrich, John W.

    1996-01-01

    Two families of finite difference algorithms for computational aeroacoustics are presented and compared. All of the algorithms are single step explicit methods, they have the same order of accuracy in both space and time, with examples up to eleventh order, and they have multidimensional extensions. One of the algorithm families has spectral like high resolution. Propagation with high order and high resolution algorithms can produce accurate results after O(10(exp 6)) periods of propagation with eight grid points per wavelength.

  11. Integrated diagnostics

    NASA Technical Reports Server (NTRS)

    Hunthausen, Roger J.

    1988-01-01

    Recently completed projects in which advanced diagnostic concepts were explored and/or demonstrated are summarized. The projects begin with the design of integrated diagnostics for the Army's new gas turbine engines, and advance to the application of integrated diagnostics to other aircraft subsystems. Finally, a recent project is discussed which ties together subsystem fault monitoring and diagnostics with a more complete picture of flight domain knowledge.

  12. ROM Plus®: accurate point-of-care detection of ruptured fetal membranes

    PubMed Central

    McQuivey, Ross W; Block, Jon E

    2016-01-01

    Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article. PMID:27274316

  13. ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes.

    PubMed

    McQuivey, Ross W; Block, Jon E

    2016-01-01

    Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article. PMID:27274316

  14. Transbronchial needle aspiration. An underused diagnostic technique.

    PubMed

    Dasgupta, A; Mehta, A C

    1999-03-01

    (by watching video) Review pathology slides Acquisition of skills with cytology needles should precede the use of the histology needle. Increasing education and experience can also increase diagnostic yields. Transbronchial needle aspiration has been proven to be accurate in staging lung cancers, identifying inoperable carcinomas, and diagnosing a variety of lung diseases. Few complications have been encountered and the technique is less invasive and less costly than surgical procedures. Drawing on evidence from published literature, we suggest the following guidelines for TBNA: All patients presenting with mediastinal or hilar adenopathy or both, should have 22-ga and/or 19-ga TBNA as the initial procedure. These procedures would help diagnose malignant and nonmalignant diseases, and stage lung cancers. All patients with evidence of submucosal and peribronchial disease should have 22-ga needle cytology sampling. In patients with visible endobronchial disease, 22-ga TBNA should be optional. In the presence of a necrotic or a hemorrhagic tumor, or in a patient with a bleeding diathesis, TBNA would be helpful. In all patients with Type III and IV peripheral nodules, TBNA should be the initial diagnostic procedure. There remains no doubt about the diagnostic usefulness of TBNA. Guidelines must be developed to ensure that pulmonary fellows are adequately trained in this procedure. Regional workshops with hands-on experience targeted to practicing pulmonologists organized by the ACCP would help popularize the procedure. Initial low yields should not discourage pulmonologists from using the procedure. Collaboration between thoracic surgeons, oncologists, and pulmonary physicians is essential to set up TBNA programs within institutions. With time, as more and more pulmonologists attain expertise in TBNA, the full potential of this nonsurgical, cost-effective, and safe procedure will be realized. PMID:10205716

  15. Diagnostic peritoneal lavage - series (image)

    MedlinePlus

    ... abdominal injury has occurred in a blunt trauma victim. In many cases, the decision about when to ... One procedure used to determine whether blunt trauma victims require surgery is diagnostic peritoneal lavage (DPL). DPL ...

  16. Integrated diagnostics: proceedings from the 9th biennial symposium of the International Society for Strategic Studies in Radiology.

    PubMed

    Krestin, G P; Grenier, P A; Hricak, H; Jackson, V P; Khong, P L; Miller, J C; Muellner, A; Schwaiger, M; Thrall, J H

    2012-11-01

    The International Society for Strategic Studies in Radiology held its 9th biennial meeting in August 2011. The focus of the programme was integrated diagnostics and massive computing. Participants discussed the opportunities, challenges, and consequences for the discipline of radiology that will likely arise from the integration of diagnostic technologies. Diagnostic technologies are increasing in scope, including advanced imaging techniques, new molecular imaging agents, and sophisticated point-of-use devices. Advanced information technology (IT), which is increasingly influencing the practice of medicine, will aid clinical communication and the development of "population images" that represent the phenotype of particular diseases, which will aid the development of diagnostic algorithms. Integrated diagnostics offer increased operational efficiency and benefits to patients through quicker and more accurate diagnoses. As physicians with the most expertise in IT, radiologists are well placed to take the lead in introducing IT solutions and cloud computing to promote integrated diagnostics. To achieve this, radiologists must adapt to include quantitative data on biomarkers in their reports. Radiologists must also increase their role as participating physicians, collaborating with other medical specialties, not only to avoid being sidelined by other specialties but also to better prepare as leaders in the selection and sequence of diagnostic procedures. Key Points • New diagnostic technologies are yielding unprecedented amounts of diagnostic information.• Advanced IT/cloud computing will aid integration and analysis of diagnostic data.• Better diagnostic algorithms will lead to faster diagnosis and more rapid treatment. PMID:22699871

  17. Accurate measurement of time

    NASA Astrophysics Data System (ADS)

    Itano, Wayne M.; Ramsey, Norman F.

    1993-07-01

    The paper discusses current methods for accurate measurements of time by conventional atomic clocks, with particular attention given to the principles of operation of atomic-beam frequency standards, atomic hydrogen masers, and atomic fountain and to the potential use of strings of trapped mercury ions as a time device more stable than conventional atomic clocks. The areas of application of the ultraprecise and ultrastable time-measuring devices that tax the capacity of modern atomic clocks include radio astronomy and tests of relativity. The paper also discusses practical applications of ultraprecise clocks, such as navigation of space vehicles and pinpointing the exact position of ships and other objects on earth using the GPS.

  18. Accurate quantum chemical calculations

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Langhoff, Stephen R.; Taylor, Peter R.

    1989-01-01

    An important goal of quantum chemical calculations is to provide an understanding of chemical bonding and molecular electronic structure. A second goal, the prediction of energy differences to chemical accuracy, has been much harder to attain. First, the computational resources required to achieve such accuracy are very large, and second, it is not straightforward to demonstrate that an apparently accurate result, in terms of agreement with experiment, does not result from a cancellation of errors. Recent advances in electronic structure methodology, coupled with the power of vector supercomputers, have made it possible to solve a number of electronic structure problems exactly using the full configuration interaction (FCI) method within a subspace of the complete Hilbert space. These exact results can be used to benchmark approximate techniques that are applicable to a wider range of chemical and physical problems. The methodology of many-electron quantum chemistry is reviewed. Methods are considered in detail for performing FCI calculations. The application of FCI methods to several three-electron problems in molecular physics are discussed. A number of benchmark applications of FCI wave functions are described. Atomic basis sets and the development of improved methods for handling very large basis sets are discussed: these are then applied to a number of chemical and spectroscopic problems; to transition metals; and to problems involving potential energy surfaces. Although the experiences described give considerable grounds for optimism about the general ability to perform accurate calculations, there are several problems that have proved less tractable, at least with current computer resources, and these and possible solutions are discussed.

  19. Beamlet laser diagnostics

    SciTech Connect

    Burkhart, S.C.; Behrendt, W.C.; Smith, I.

    1996-06-01

    Beamlet is instrumented extensively to monitor the performance of the overall laser system and many of its subsystems. Beam diagnostics, installed in key locations, are used to fully characterize the beam during its propagation through the multipass cavity and the laser`s output section. This article describes the diagnostics stations located on Beamlet and discusses the design, calibration, and performance of the Beamlet calorimeters. The authors used Nova`s diagnostics packages to develop the Beamlet design to determine beam energy, spatial profile, temporal profile, and other beam parameters. Technologic improvements within the last several years in controls, charge-coupled device (CCD) cameras, and fast oscilloscopes have allowed the authors to obtain more accurate measurements on the Beamlet laser system. They briefly cover some of these techniques, including a description of their LabVIEW based data acquisition system.

  20. Faster and More Accurate Transport Procedures for HZETRN

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Blattnig, Steve R.; Badavi, Francis F.

    2010-01-01

    Several aspects of code verification are examined for HZETRN. First, a detailed derivation of the numerical marching algorithms is given. Next, a new numerical method for light particle transport is presented, and improvements to the heavy ion transport algorithm are discussed. A summary of various coding errors is also given, and the impact of these errors on exposure quantities is shown. Finally, a coupled convergence study is conducted. From this study, it is shown that past efforts in quantifying the numerical error in HZETRN were hindered by single precision calculations and computational resources. It is also determined that almost all of the discretization error in HZETRN is caused by charged target fragments below 50 AMeV. Total discretization errors are given for the old and new algorithms, and the improved accuracy of the new numerical methods is demonstrated. Run time comparisons are given for three applications in which HZETRN is commonly used. The new algorithms are found to be almost 100 times faster for solar particle event simulations and almost 10 times faster for galactic cosmic ray simulations.

  1. Faster and more accurate transport procedures for HZETRN

    SciTech Connect

    Slaba, T.C.; Blattnig, S.R.; Badavi, F.F.

    2010-12-10

    The deterministic transport code HZETRN was developed for research scientists and design engineers studying the effects of space radiation on astronauts and instrumentation protected by various shielding materials and structures. In this work, several aspects of code verification are examined. First, a detailed derivation of the light particle (A {<=} 4) and heavy ion (A > 4) numerical marching algorithms used in HZETRN is given. References are given for components of the derivation that already exist in the literature, and discussions are given for details that may have been absent in the past. The present paper provides a complete description of the numerical methods currently used in the code and is identified as a key component of the verification process. Next, a new numerical method for light particle transport is presented, and improvements to the heavy ion transport algorithm are discussed. A summary of round-off error is also given, and the impact of this error on previously predicted exposure quantities is shown. Finally, a coupled convergence study is conducted by refining the discretization parameters (step-size and energy grid-size). From this study, it is shown that past efforts in quantifying the numerical error in HZETRN were hindered by single precision calculations and computational resources. It is determined that almost all of the discretization error in HZETRN is caused by the use of discretization parameters that violate a numerical convergence criterion related to charged target fragments below 50 AMeV. Total discretization errors are given for the old and new algorithms to 100 g/cm{sup 2} in aluminum and water, and the improved accuracy of the new numerical methods is demonstrated. Run time comparisons between the old and new algorithms are given for one, two, and three layer slabs of 100 g/cm{sup 2} of aluminum, polyethylene, and water. The new algorithms are found to be almost 100 times faster for solar particle event simulations and almost 10 times faster for galactic cosmic ray simulations.

  2. Nursing Procedures. NAVMED P-5066.

    ERIC Educational Resources Information Center

    Bureau of Medicine and Surgery (Navy), Washington, DC.

    The revised manual of nursing procedures covers fundamental nursing care, admission and discharge of the patient, assisting with therapeutic measures, pre- and postoperative care, diagnostic tests and procedures, and isolation technique. Each of the over 300 topics includes the purpose, equipment, and procedure to be used and, where relevant, such…

  3. New Diagnostic Aides for Melanoma

    PubMed Central

    Ferris, Laura K.; Harris, Ryan J.

    2012-01-01

    Synopsis Detection of melanoma at an early stage is crucial to improving survival rates in melanoma. Accurate diagnosis by current techniques including dermatoscopy remains difficult, and new tools are needed to improve our diagnostic abilities. This article discusses recent advances in diagnostic techniques including confocal scanning laser microscopy, MelaFind, Siascopy, noninvasive genomic detection, as well as other future possibilities to aid in diagnosing melanoma. Advantages and barriers to implementation of the various technologies are discussed as well. PMID:22800557

  4. Diagnostic procedures in cardiology: A clinician's guide

    SciTech Connect

    Warren, J.V.; Lewis, R.P.

    1985-01-01

    This book contains 31 papers. Some of the titles are: Cardiovascular radiology; Nuclear cardiology; echocardiography; The use and conduct of exercise tests; Lipid studies in cardiology; and The practice of cardiology in an era of high technology.

  5. Recent advances in salivary cancer diagnostics enabled by biosensors and bioelectronics.

    PubMed

    Mishra, Saswat; Saadat, Darius; Kwon, Ohjin; Lee, Yongkuk; Choi, Woon-Seop; Kim, Jong-Hoon; Yeo, Woon-Hong

    2016-07-15

    There is a high demand for a non-invasive, rapid, and highly accurate tool for disease diagnostics. Recently, saliva based diagnostics for the detection of specific biomarkers has drawn significant attention since the sample extraction is simple, cost-effective, and precise. Compared to blood, saliva contains a similar variety of DNA, RNA, proteins, metabolites, and microbiota that can be compiled into a multiplex of cancer detection markers. The salivary diagnostic method holds great potential for early-stage cancer diagnostics without any complicated and expensive procedures. Here, we review various cancer biomarkers in saliva and compare the biomarkers efficacy with traditional diagnostics and state-of-the-art bioelectronics. We summarize biomarkers in four major groups: genomics, transcriptomics, proteomics, and metabolomics/microbiota. Representative bioelectronic systems for each group are summarized based on various stages of a cancer. Systematic study of oxidative stress establishes the relationship between macromolecules and cancer biomarkers in saliva. We also introduce the most recent examples of salivary diagnostic electronics based on nanotechnologies that can offer rapid, yet highly accurate detection of biomarkers. A concluding section highlights areas of opportunity in the further development and applications of these technologies. PMID:26946257

  6. Diagnostic Imaging

    MedlinePlus

    Diagnostic imaging lets doctors look inside your body for clues about a medical condition. A variety of machines and ... and activities inside your body. The type of imaging your doctor uses depends on your symptoms and ...

  7. Diagnostic radiology

    SciTech Connect

    Leeds, N.E.; Jacobson, H.G.

    1986-10-17

    Developments in the burgeoning field of diagnostic radiology have continued apace. Four areas that represent either subspecialities or technological advances in diagnostic radiology will be considered in this report: ultrasonography, interventional radiology, nuclear radiology, and magnetic resonance. In no sense is the exclusion of other subdisciplines and modalities (eg, pediatric radiology, computed tomography) and indication of their of importance or their failure to include innovative concepts.

  8. Salivary biomarkers: toward future clinical and diagnostic utilities.

    PubMed

    Yoshizawa, Janice M; Schafer, Christopher A; Schafer, Jason J; Farrell, James J; Paster, Bruce J; Wong, David T W

    2013-10-01

    The pursuit of timely, cost-effective, accurate, and noninvasive diagnostic methodologies is an endeavor of urgency among clinicians and scientists alike. Detecting pathologies at their earliest stages can significantly affect patient discomfort, prognosis, therapeutic intervention, survival rates, and recurrence. Diagnosis and monitoring often require painful invasive procedures such as biopsies and repeated blood draws, adding undue stress to an already unpleasant experience. The discovery of saliva-based microbial, immunologic, and molecular biomarkers offers unique opportunities to bypass these measures by utilizing oral fluids to evaluate the condition of both healthy and diseased individuals. Here we discuss saliva and its significance as a source of indicators for local, systemic, and infectious disorders. We highlight contemporary innovations and explore recent discoveries that deem saliva a mediator of the body's physiological condition. Additionally, we examine the current state of salivary diagnostics and its associated technologies, future aspirations, and potential as the preferred route of disease detection, monitoring, and prognosis. PMID:24092855

  9. Salivary Biomarkers: Toward Future Clinical and Diagnostic Utilities

    PubMed Central

    Yoshizawa, Janice M.; Schafer, Christopher A.; Schafer, Jason J.; Farrell, James J.; Paster, Bruce J.

    2013-01-01

    SUMMARY The pursuit of timely, cost-effective, accurate, and noninvasive diagnostic methodologies is an endeavor of urgency among clinicians and scientists alike. Detecting pathologies at their earliest stages can significantly affect patient discomfort, prognosis, therapeutic intervention, survival rates, and recurrence. Diagnosis and monitoring often require painful invasive procedures such as biopsies and repeated blood draws, adding undue stress to an already unpleasant experience. The discovery of saliva-based microbial, immunologic, and molecular biomarkers offers unique opportunities to bypass these measures by utilizing oral fluids to evaluate the condition of both healthy and diseased individuals. Here we discuss saliva and its significance as a source of indicators for local, systemic, and infectious disorders. We highlight contemporary innovations and explore recent discoveries that deem saliva a mediator of the body's physiological condition. Additionally, we examine the current state of salivary diagnostics and its associated technologies, future aspirations, and potential as the preferred route of disease detection, monitoring, and prognosis. PMID:24092855

  10. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic

  11. Fungal Diagnostics

    PubMed Central

    Kozel, Thomas R.; Wickes, Brian

    2014-01-01

    Early diagnosis of fungal infection is critical to effective treatment. There are many impediments to diagnosis such as a diminishing number of clinical mycologists, cost, time to result, and requirements for sensitivity and specificity. In addition, fungal diagnostics must meet the contrasting needs presented by the increasing diversity of fungi found in association with the use of immunosuppressive agents in countries with high levels of medical care and the need for diagnostics in resource-limited countries where large numbers of opportunistic infections occur in patients with AIDS. Traditional approaches to diagnosis include direct microscopic examination of clinical samples, histopathology, culture, and serology. Emerging technologies include molecular diagnostics and antigen detection in clinical samples. Innovative new technologies that use molecular and immunoassay platforms have the potential to meet the needs of both resource-rich and resource-limited clinical environments. PMID:24692193

  12. DIAGNOSTICS OF BNL ERL

    SciTech Connect

    POZDEYEV,E.; BEN-ZVI, I.; CAMERON, P.; GASSNER, D.; KAYRAN, D.; ET AL.

    2007-06-25

    The ERL Prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high-intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high-current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This paper outlines requirements on the ERL diagnostics and describes its setup and modes of operation.

  13. Diagnostic imaging in pediatric emergencies

    SciTech Connect

    Heller, R.M.; Coulam, C.M.; Allen, J.H.; Fleischer, A.; Lee, G.S.; Kirchner, S.G.; James A.E. Jr.

    1980-07-01

    Evaluation of pediatric emergencies by diagnostic imaging technics can involve both invasive and noninvasive procedures. Nuclear medicine, conventional radiography, ultrasound, computerized axial tomography, and xeroradiography are the major nonangiographic diagnostic technics available for patient evaluation. We will emphasize the use of computerized axial tomography, nuclear medicine, xeroradiography, and ultrasound in the evaluation of emergencies in the pediatric age group. Since the radiologist is the primary consultant with regard to diagnostic imaging, his knowledge of these modulities can greatly influence patient care and clinical results.

  14. How safe is diagnostic ultrasonography?

    PubMed Central

    Brown, B S

    1984-01-01

    Health care workers and patients alike are concerned about the safety of diagnostic ultrasonography in clinical practice. Evidence published to date on the immediate and possible long-term biologic effects of exposure to ultrasound in diagnostic procedures is reviewed in this paper. No harmful effect in the human fetus, child or adult following the diagnostic use of pulsed ultrasound has been reported. However, the question of long-term biologic effects cannot yet be answered. Continued vigilance and further research are required. PMID:6378349

  15. Knowledge based jet engine diagnostics

    NASA Technical Reports Server (NTRS)

    Jellison, Timothy G.; Dehoff, Ronald L.

    1987-01-01

    A fielded expert system automates equipment fault isolation and recommends corrective maintenance action for Air Force jet engines. The knowledge based diagnostics tool was developed as an expert system interface to the Comprehensive Engine Management System, Increment IV (CEMS IV), the standard Air Force base level maintenance decision support system. XMAM (trademark), the Expert Maintenance Tool, automates procedures for troubleshooting equipment faults, provides a facility for interactive user training, and fits within a diagnostics information feedback loop to improve the troubleshooting and equipment maintenance processes. The application of expert diagnostics to the Air Force A-10A aircraft TF-34 engine equipped with the Turbine Engine Monitoring System (TEMS) is presented.

  16. A novel, non-invasive diagnostic clinical procedure for the determination of an oxygenation status of chronic lower leg ulcers using peri-ulceral transcutaneous oxygen partial pressure measurements: Results of its application in chronic venous insufficiency (CVI)

    PubMed Central

    Barnikol, Wolfgang K. R.; Pötzschke, Harald

    2012-01-01

    wounds. The hypoxia grades found in all of the chronic wounds was seen to be evenly distributed with values ranging from 0 to 40 mmHg, and therefore extremely inhomogeneous. In terms of oxygenation, chronic wounds are therefore inhomogeneous in two respects: (1) within the wound itself (intra-individual wound inhomogeneity) and (2) between different wounds (inter-individual wound inhomogeneity). Due to the extreme oxygen inhomogeneity, single measurements are not diagnostically useful. In healthy individuals the oxygen inhalation challenge (see above) results in synchronised tcPO2 oscillations occurring at minute rhythms, which are not seen in CVI wounds. These oscillations can be interpreted as a sign of a functioning arterial vasomotor system. The new procedure is suitable for the routine characterisation of chronic wounds in terms of their oxygen status, and correspondingly, their metabolically determining (and limiting) potential for healing and regeneration. The oxygen characteristic K-PO2 can furthermore be used as a warning of impending ulceration, since the oxygen provision worsens over time prior to the demise of the ulcerated tissue, thus making a controlled prophylaxis possible. PMID:22737104

  17. Follow-up of Wilms tumor: comparison of CT with other imaging procedures

    SciTech Connect

    Brasch, R.C.; Randel, S.B.; Gould, R.G.

    1981-11-01

    In a retrospective review, computed tomography (CT) was compared to a ''routine'' combination of other diagnostic imaging procedures used for follow-up evaluations of 13 children being treated for Wilms tumor. The examined variables were diagnostic accuracy, expense, and duration of examination. Results from 13 patients indicated that CT most accurately answers diagnostic queries pertinent to follow-up evaluation of Wilms tumors: the presence and extent of bilateral renal tumors, local recurrence, contralateral renal hypertrophy, and metastasis to liver or lungs. For diagnosing pulmonary metastases, CT was superior to conventional chest radiography both in sensitivity (4/4 vs. 2/4) and specificity (9/9 vs. 6/9). In depiction of liver metastases, CT (3/3) was superior to liver scintigraphy (2/3). The extent of bilateral Wilms tumors was better defined by CT than by urography. In no instances were the alternative diagnostic imaging studies found to be more accurate than CT for the detection of recurrent tumor. Average cost for a CT examination ($344) is considerably less than the cost for a routine combination of the other imaging studies ($594). Examination time and diagnostic radiation doses are also reduced using CT. Pending larger comparison studies, CT is recommended as the primary diagnostic method for follow-up evaluation of patients with Wilms tumor.

  18. The optimal diagnostic workup for children with suspected food allergy.

    PubMed

    Berni Canani, Roberto; Di Costanzo, Mara; Troncone, Riccardo

    2011-10-01

    Food allergy is defined as an abnormal immunologic reaction to food proteins that causes an adverse clinical reaction. In addition to well-known acute allergic reactions and anaphylaxis triggered by immunoglobulin E antibody-mediated immune responses to food proteins, there is an increasing recognition of cell-mediated disorders such as eosinophilic esophagitis and food protein-induced enterocolitis syndrome. More than 90% of food allergies in childhood are caused by eight foods: cow's milk, hen's egg, soy, peanuts, tree nuts, wheat, fish, and shellfish. The diagnostic workup for a child with suspected food allergy includes a detailed medical history, physical examination, food allergy screening tests, and responses to an elimination diet and an oral food challenge. None of the screening tests, alone or in combination, can definitely diagnose or exclude a food allergy. Novel diagnostic methods including those that focus on immune responses to specific food proteins or epitopes of specific proteins are under active study. Unconventional diagnostic methods are increasingly used, but they lack scientific rationale, standardization, and reproducibility. In selected cases, such as eosinophilic esophageal gastroenteropathies or food protein-induced gastroesophageal reflux disease, invasive procedures are mandatory for an accurate diagnosis. Properly done, an oral food challenge is still the gold standard in the diagnostic workup. An incorrect diagnosis is likely to result in unnecessary dietary restrictions, which, if prolonged, may adversely affect the child's nutritional status and growth. PMID:21907896

  19. FEL-accelerator related diagnostics

    SciTech Connect

    Kevin Jordan; David Douglas; Stephen V. Benson; Pavel Evtuschenko

    2007-08-02

    Free Electron Lasers (FEL) present a unique set of beam parameters to the diagnostics suite. The FEL requires characterization of the full six dimensional phase space of the electron beam at the wiggler and accurate alignment of the electron beam to the optical mode of the laser. In addition to the FEL requirements on the diagnostics suite, the Jefferson Lab FEL is operated as an Energy Recovered Linac (ERL) which imposes additional requirements on the diagnostics. The ERL aspect of the Jefferson Lab FEL requires that diagnostics operate over a unique dynamic range and operate with simultaneous transport of the accelerated and energy recovered beams. This talk will present how these challenges are addressed at the Jefferson Lab FEL.

  20. Rapid diagnostic tests for malaria

    PubMed Central

    Daily, Jennifer; Hotte, Nora; Dolkart, Caitlin; Cunningham, Jane; Yadav, Prashant

    2015-01-01

    Abstract Maintaining quality, competitiveness and innovation in global health technology is a constant challenge for manufacturers, while affordability, access and equity are challenges for governments and international agencies. In this paper we discuss these issues with reference to rapid diagnostic tests for malaria. Strategies to control and eliminate malaria depend on early and accurate diagnosis. Rapid diagnostic tests for malaria require little training and equipment and can be performed by non-specialists in remote settings. Use of these tests has expanded significantly over the last few years, following recommendations to test all suspected malaria cases before treatment and the implementation of an evaluation programme to assess the performance of the malaria rapid diagnostic tests. Despite these gains, challenges exist that, if not addressed, could jeopardize the progress made to date. We discuss recent developments in rapid diagnostic tests for malaria, highlight some of the challenges and provide suggestions to address them. PMID:26668438

  1. Are Kohn-Sham conductances accurate?

    PubMed

    Mera, H; Niquet, Y M

    2010-11-19

    We use Fermi-liquid relations to address the accuracy of conductances calculated from the single-particle states of exact Kohn-Sham (KS) density functional theory. We demonstrate a systematic failure of this procedure for the calculation of the conductance, and show how it originates from the lack of renormalization in the KS spectral function. In certain limits this failure can lead to a large overestimation of the true conductance. We also show, however, that the KS conductances can be accurate for single-channel molecular junctions and systems where direct Coulomb interactions are strongly dominant. PMID:21231333

  2. Diagnostic laparoscopy

    MedlinePlus

    ... an accident to see if there is any injury to the abdomen. Laparoscopy may be done before procedures to treat ... of the ovary Pelvic inflammatory disease Signs of injury Spread of cancer Tumors Uterine fibroids

  3. How to accurately bypass damage

    PubMed Central

    Broyde, Suse; Patel, Dinshaw J.

    2016-01-01

    Ultraviolet radiation can cause cancer through DNA damage — specifically, by linking adjacent thymine bases. Crystal structures show how the enzyme DNA polymerase η accurately bypasses such lesions, offering protection. PMID:20577203

  4. Accurate Evaluation of Quantum Integrals

    NASA Technical Reports Server (NTRS)

    Galant, David C.; Goorvitch, D.

    1994-01-01

    Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schr\\"{o}dinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

  5. [Imaging and Laboratory Diagnostics for Tuberculosis].

    PubMed

    Bauer, C M; Schmähl, A; Kreuter, M

    2016-05-01

    Diagnosis of tuberculosis (TB) is difficult, since symptoms are often very unspecific or lacking. However active, prompt and accurate diagnosis is the key element in the public health response to tuberculosis and the cornerstone of tuberculosis control. Different diagnostic methods for an assured diagnosis of TB are necessary. Chest radiography is a useful keystone to identify tuberculosis, but diagnosis of tuberculosis cannot be established by radiography alone. CT scanning is used in patients without pathological chest radiography but clinically suspected active TB and to differentiate TB from other diseases. Radiological appearance is primarily determined by the immune status of patients and caverns and disseminated disease foci are often observed. Laboratory diagnostic methods include microscopic identification of acid-fast mycobacteria from any body fluid (especially sputum), as well as isolation and characterisation of mycobacteria in culture. It is then possible to type the pathogens by the shape of their colony, their growth behavior and their biochemical characteristics. These methods are regarded as the gold standard in diagnosis of active TB. In patients who are highly suspected of having TB, but whose sputum specimens tested negative for mycobacteria, a nucleic acid amplification test is additionally performed. Moreover, sensitivity testing with first and second line antitubercular drugs is applied as standard. Laboratory diagnostic testing of cellular immunity against pathogenic mycobacteria employs the tuberculin skin test (TST, Mantoux tuberculin test) or the more specific interferon γ test to determine γ interferon released by T lymphocytes stimulated in vitro. The new ELISA and ELISPOT procedures exhibit higher test specificity and less cross reactivity to NTM (non-tuberculosis mycobacteria), are independent of BCG-vaccination status and correlate better with the degree of exposure than does the TST. PMID:27187878

  6. SDQ: discriminative validity and diagnostic potential

    PubMed Central

    Silva, Thaysa B. F.; Osório, Flávia L.; Loureiro, Sonia R.

    2015-01-01

    The Strengths and Difficulties Questionnaire (SDQ) was designed to screen for behavioral problems in youths based on cutoff points that favor the instrument's diagnostic sensitivity. The present study aimed to analyze the discriminative validity of the SDQ to identify behavioral difficulties and prosocial resources in school-age children compared with the diagnostic data collected by the corresponding sections of the Development and Well-being Assessment (DAWBA). In addition, new cutoff points that value specificity were defined for the SDQ scales, exploring its diagnostic potential. This study was conducted in Brazil and assessed a community convenience sample that consisted of 120 children aged 6–12 years who were not under psychological/psychiatric treatment. The mothers of the participants also completed a sociodemographic questionnaire. Descriptive statistics were used to clinically characterize the sample. A ROC curve was used to assess the discriminant validity of the SDQ, and new cutoff points were established to maximize the instrument's specificity. The new cutoff points enabled a significant increase in specificity without a significant loss of sensitivity, which favors approaches based on measures of screening and diagnosis yet does not damage the instrument's screening capacity. The following increases were observed: 100% for the depressive disorder scale (cutoff point = 7), 95.1% for the generalized anxiety disorder scale (cutoff point = 7), 46.6% for the conduct disorder scale (cutoff point = 6), 19.2% for the hyperactive disorder scale (cutoff point = 8), and 27.6% for the antisocial personality disorder scale (cutoff point = 6). A cutoff point of 8 was applied to the prosocial behavior scale, which exhibited a 62.1% increase in specificity. The use of more specific cutoff points generated more accurate results and favored SDQ's use, particularly in contexts of care that require more precise and faster procedures for identification of problems

  7. SDQ: discriminative validity and diagnostic potential.

    PubMed

    Silva, Thaysa B F; Osório, Flávia L; Loureiro, Sonia R

    2015-01-01

    The Strengths and Difficulties Questionnaire (SDQ) was designed to screen for behavioral problems in youths based on cutoff points that favor the instrument's diagnostic sensitivity. The present study aimed to analyze the discriminative validity of the SDQ to identify behavioral difficulties and prosocial resources in school-age children compared with the diagnostic data collected by the corresponding sections of the Development and Well-being Assessment (DAWBA). In addition, new cutoff points that value specificity were defined for the SDQ scales, exploring its diagnostic potential. This study was conducted in Brazil and assessed a community convenience sample that consisted of 120 children aged 6-12 years who were not under psychological/psychiatric treatment. The mothers of the participants also completed a sociodemographic questionnaire. Descriptive statistics were used to clinically characterize the sample. A ROC curve was used to assess the discriminant validity of the SDQ, and new cutoff points were established to maximize the instrument's specificity. The new cutoff points enabled a significant increase in specificity without a significant loss of sensitivity, which favors approaches based on measures of screening and diagnosis yet does not damage the instrument's screening capacity. The following increases were observed: 100% for the depressive disorder scale (cutoff point = 7), 95.1% for the generalized anxiety disorder scale (cutoff point = 7), 46.6% for the conduct disorder scale (cutoff point = 6), 19.2% for the hyperactive disorder scale (cutoff point = 8), and 27.6% for the antisocial personality disorder scale (cutoff point = 6). A cutoff point of 8 was applied to the prosocial behavior scale, which exhibited a 62.1% increase in specificity. The use of more specific cutoff points generated more accurate results and favored SDQ's use, particularly in contexts of care that require more precise and faster procedures for identification of problems. PMID

  8. High Frequency QRS ECG Accurately Detects Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian; Poulin, Gregory; Moser, Daniel R.; Delgado, Reynolds

    2005-01-01

    High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing

  9. Diagnostic Laparoscopy

    MedlinePlus

    ... during the same procedure, correct the problem. Abdominal mass. A patient may have a lump (mass or tumor), which can be felt by the ... to your physician to look directly at the mass and obtain tissue to discover the diagnosis. Ascites. ...

  10. 40 CFR 1060.505 - Other procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equivalent to allowed procedures or are more accurate or more precise than allowed procedures. See 40 CFR... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test...

  11. 40 CFR 1060.505 - Other procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equivalent to allowed procedures or are more accurate or more precise than allowed procedures. See 40 CFR... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test...

  12. 40 CFR 1060.505 - Other procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equivalent to allowed procedures or are more accurate or more precise than allowed procedures. See 40 CFR... CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY EQUIPMENT Test...

  13. PROcess Based Diagnostics PROBE

    NASA Technical Reports Server (NTRS)

    Clune, T.; Schmidt, G.; Kuo, K.; Bauer, M.; Oloso, H.

    2013-01-01

    Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

  14. Rotorcraft Diagnostics

    NASA Technical Reports Server (NTRS)

    Haste, Deepak; Azam, Mohammad; Ghoshal, Sudipto; Monte, James

    2012-01-01

    Health management (HM) in any engineering systems requires adequate understanding about the system s functioning; a sufficient amount of monitored data; the capability to extract, analyze, and collate information; and the capability to combine understanding and information for HM-related estimation and decision-making. Rotorcraft systems are, in general, highly complex. Obtaining adequate understanding about functioning of such systems is quite difficult, because of the proprietary (restricted access) nature of their designs and dynamic models. Development of an EIM (exact inverse map) solution for rotorcraft requires a process that can overcome the abovementioned difficulties and maximally utilize monitored information for HM facilitation via employing advanced analytic techniques. The goal was to develop a versatile HM solution for rotorcraft for facilitation of the Condition Based Maintenance Plus (CBM+) capabilities. The effort was geared towards developing analytic and reasoning techniques, and proving the ability to embed the required capabilities on a rotorcraft platform, paving the way for implementing the solution on an aircraft-level system for consolidation and reporting. The solution for rotorcraft can he used offboard or embedded directly onto a rotorcraft system. The envisioned solution utilizes available monitored and archived data for real-time fault detection and identification, failure precursor identification, and offline fault detection and diagnostics, health condition forecasting, optimal guided troubleshooting, and maintenance decision support. A variant of the onboard version is a self-contained hardware and software (HW+SW) package that can be embedded on rotorcraft systems. The HM solution comprises components that gather/ingest data and information, perform information/feature extraction, analyze information in conjunction with the dependency/diagnostic model of the target system, facilitate optimal guided troubleshooting, and offer

  15. Diagnostic Potential of Pulsed Arterial Spin Labeling in Alzheimer's Disease

    PubMed Central

    Trebeschi, Stefano; Riederer, Isabelle; Preibisch, Christine; Bohn, Karl P.; Förster, Stefan; Alexopoulos, Panagiotis; Zimmer, Claus; Kirschke, Jan S.; Valentinitsch, Alexander

    2016-01-01

    Alzheimers disease (AD) is the most common cause of dementia. Although the underlying pathology is still not completely understood, several diagnostic methods are available. Frequently, the most accurate methods are also the most invasive. The present work investigates the diagnostic potential of Pulsed Arterial Spin Labeling (PASL) for AD: a non-invasive, MRI-based technique for the quantification of regional cerebral blood flow (rCBF). In particular, we propose a pilot computer aided diagnostic (CAD) procedure able to discriminate between healthy and diseased subjects, and at the same time, providing visual informative results. This method encompasses the creation of a healthy model, the computation of a voxel-wise likelihood function as comparison between the healthy model and the subject under examination, and the correction of the likelihood function via prior distributions. The discriminant analysis is carried out to maximize the accuracy of the classification. The algorithm has been trained on a dataset of 81 subjects and achieved a sensitivity of 0.750 and a specificity of 0.875. Moreover, in accordance with the current pathological knowledge, the parietal lobe, and limbic system are shown to be the main discriminant factors. PMID:27147946

  16. AB017. Interstitial lung disease patient diagnostic journey (intensity)

    PubMed Central

    Lederer, David J.; Bianchi, Pauline; Loboda, Jeanne; Danese, Sherry; Cosgrove, Gregory P.

    2016-01-01

    Background Interstitial lung disease (ILD) is complicated to diagnose because its signs and symptoms mimic a wide range of common medical conditions. The objective of the INTENSITY survey was to advance the understanding of respondents’ diagnostic experiences with ILDs, including idiopathic pulmonary fibrosis (IPF). The survey was designed to trace the path that respondents took to diagnosis, identify obstacles they faced, and gauge the emotional impact of their journey. Results from the INTENSITY survey will help us more fully understand respondents’ diagnostic experiences so we can further our efforts to improve timely diagnosis and treatment of ILDs. Methods We administered a 25-minute quantitative online survey from August 14–26, 2015. Of the 1,152 respondents screened to ensure they were US residents, and had been diagnosed with an interstitial lung disease, 600 met criteria and completed the survey. Recruitment was accomplished through two channels: email invitations sent to 16,000 Pulmonary Fibrosis Foundation (PFF) members and an open invitation to participate through the pulmonary fibrosis community website Results Shortness of breath (77%) and cough (53%) were the most common early symptoms in ILD patients. Twenty-five percent of respondents saw their primary care physician once before being referred to a specialist, however 61% of respondents saw their primary care physician >2 times before referral to a pulmonologist. Misdiagnosis occurred in 55% of respondents. The median time from symptom onset to correct diagnosis was 11 months, however 49% of respondents carried an incorrect diagnosis for 1 to 10 years. Thirty-eight percent were misdiagnosed more than twice, most frequently with asthma, pneumonia, bronchitis, and allergies. An accurate diagnosis was achieved after a median of 6 months and a median of 3 physician visits. The majority underwent an invasive diagnostic procedure. Fourteen percent of respondents saw more than 6 physicians before

  17. Accurate Telescope Mount Positioning with MEMS Accelerometers

    NASA Astrophysics Data System (ADS)

    Mészáros, L.; Jaskó, A.; Pál, A.; Csépány, G.

    2014-08-01

    This paper describes the advantages and challenges of applying microelectromechanical accelerometer systems (MEMS accelerometers) in order to attain precise, accurate, and stateless positioning of telescope mounts. This provides a completely independent method from other forms of electronic, optical, mechanical or magnetic feedback or real-time astrometry. Our goal is to reach the subarcminute range which is considerably smaller than the field-of-view of conventional imaging telescope systems. Here we present how this subarcminute accuracy can be achieved with very cheap MEMS sensors and we also detail how our procedures can be extended in order to attain even finer measurements. In addition, our paper discusses how can a complete system design be implemented in order to be a part of a telescope control system.

  18. The diagnostic utility of bone marrow aspiration and biopsy in patients with acquired immunodeficiency syndrome.

    PubMed Central

    Gluckman, R. J.; Rosner, F.; Guarneri, J. J.

    1989-01-01

    Diagnostic bone marrow aspiration, biopsy, and culture are useful procedures in the evaluation of patients with suspected or proven acquired immunodeficiency syndrome (AIDS) who are febrile. In as many as one fourth of these patients, the information provided by the bone marrow examination may establish a diagnosis of a disseminated opportunistic infection when other studies are not informative. We have also discovered a previously unreported association between thrombocytopenia and the presence of bone marrow granulomas in our patients with AIDS and suggest that thrombocytopenia may be a clue to enable the clinician to predict a positive bone marrow result more accurately. The explanation for this apparent association remains to be elucidated. PMID:2733050

  19. Instrumentation and diagnostics

    SciTech Connect

    Nakaishi, C.V.; Bedick, R.C.

    1990-12-01

    This Technology Status Report describes research and accomplishments for the Instrumentation and Diagnostics (I D) Projects within the Advanced Research and Technology Development (AR TD) Program of the United States Department of Energy (DOE) Office of Fossil Energy (FE). Process understanding and control can be improved through the development of advanced instrumentation and diagnostics. The thrust of the I D Projects is to further develop existing measurement and control techniques for application to advanced coal-based technologies. Project highlights are: an inductively coupled plasma (ICP) instrument has been developed to analyze trace elements in gasification and combustion process streams. An in situ two-color Mie scattering technique with LSS can simultaneously measure the size, velocity, and elemental composition of coal particles during combustion. A high-temperature, fluorescence thermometry technique has accurately measured gas temperatures during field testing in combustion and gasification environments. Expert systems have been developed to improve the control of advanced coal-based processes. Capacitance flowmeters were developed to determine the mass flowrate, solid volume fraction, and particle velocities of coal slurries. 32 refs., 9 figs.

  20. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  1. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (These... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights,...

  2. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (These... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights,...

  3. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (These... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights,...

  4. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (These... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights,...

  5. 9 CFR 442.3 - Scale requirements for accurate weights, repairs, adjustments, and replacements after inspection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (These... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Scale requirements for accurate... PROCEDURES AND REQUIREMENTS FOR ACCURATE WEIGHTS § 442.3 Scale requirements for accurate weights,...

  6. Bovine Staphylococcus aureus: diagnostic properties of specific media.

    PubMed

    Graber, H U; Pfister, S; Burgener, P; Boss, R; Meylan, M; Hummerjohann, J

    2013-08-01

    As accurate discrimination between Staphylococcus (S.) aureus and NSA (non-S. aureus staphylococci) involved in bovine mastitis is essential in terms of clinical prognosis and outcome, the aim of this study was to reevaluate the classical bacteriological procedures to identify these agents. Various media and the coagulase tube test were investigated using 116 strains of S. aureus and 115 of NSA, all isolated from cows with spontaneous intramammary infections (IMI). Furthermore, 25 NSA reference strains were analyzed. The study demonstrated that a few media were appropriate for differentiating S. aureus from NSA, provided that the staphylococci were isolated from bovine IMI. Evaluation of hemolysis further revealed that double or incomplete hemolysis are specific for S. aureus and are, therefore, a decisive diagnostic criterion. For strains showing complete hemolysis, maximal discrimination between S. aureus and NSA was observed by subculturing them on CHROMagar Staph. aureus. PMID:23548479

  7. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  8. Introduction to DNA-Based Genetic Diagnostics

    PubMed Central

    Glickman, Richard M.; Phillips, M. Ann; Glickman, Barry W.

    1988-01-01

    Molecular biology and recombinant DNA technology are beginning to have an effect on the medical health care field, particularly in the area of clinical genetics. Dramatic improvements in the prerequisite technology are in the process of being transferred from the research lab to routine clinical laboratories. The general practitioner, along with his genetic diagnostic colleagues, can soon expect to have access to accurate and reliable diagnostic assays for a wide variety of genetic disorders. This article introduces the basic technologies involved in genetic diagnostics and provides an indication both of their limitations and their future potential. PMID:21253094

  9. Chronic Meningitis: Simplifying a Diagnostic Challenge.

    PubMed

    Baldwin, Kelly; Whiting, Chris

    2016-03-01

    Chronic meningitis can be a diagnostic dilemma for even the most experienced clinician. Many times, the differential diagnosis is broad and encompasses autoimmune, neoplastic, and infectious etiologies. This review will focus on a general approach to chronic meningitis to simplify the diagnostic challenges many clinicians face. The article will also review the most common etiologies of chronic meningitis in some detail including clinical presentation, diagnostic testing, treatment, and outcomes. By using a case-based approach, we will focus on the key elements of clinical presentation and laboratory analysis that will yield the most rapid and accurate diagnosis in these complicated cases. PMID:26888190

  10. Rapid infectious diseases diagnostics using Smartphones

    PubMed Central

    Bates, Matthew

    2015-01-01

    The “Smartphone” is an almost universal possession in high-income populations, and is rapidly becoming so in lower-income regions, particularly among urban populations, and serves social networking and a quest for information and knowledge. The field of infectious disease diagnostics is at a potential watershed moment, with the essential building blocks for the development of diagnostic assays being ever more available and affordable, which is leading to creative innovative approaches to developing much-needed accurate and simple point-of-care (POC) diagnostic tools for high disease burden, low-income settings. We review the importance and implications of a paper published in Science Translational Medicine on the development of a smartphone-powered and -controlled multiplex immunological assay that tests for HIV and syphilis simultaneously. This is reviewed in the context of other prototype smartphone-enabled/assisted diagnostic devices, and how such developments might shape the future of the POC diagnostics field. PMID:26488011

  11. [Examination procedures].

    PubMed

    Vassault, A; Arnaud, J; Szymanovicz, A

    2010-12-01

    Examination procedures have to be written for each examination according to the standard requirements. Using CE marked devices, technical inserts can be used, but because of their lack of homogeneity, it could be easier to document their use as a standard procedure. Document control policy applies for those procedures, the content of which could be as provided in this document. Electronic manuals can be used as well. PMID:21613016

  12. Predict amine solution properties accurately

    SciTech Connect

    Cheng, S.; Meisen, A.; Chakma, A.

    1996-02-01

    Improved process design begins with using accurate physical property data. Especially in the preliminary design stage, physical property data such as density viscosity, thermal conductivity and specific heat can affect the overall performance of absorbers, heat exchangers, reboilers and pump. These properties can also influence temperature profiles in heat transfer equipment and thus control or affect the rate of amine breakdown. Aqueous-amine solution physical property data are available in graphical form. However, it is not convenient to use with computer-based calculations. Developed equations allow improved correlations of derived physical property estimates with published data. Expressions are given which can be used to estimate physical properties of methyldiethanolamine (MDEA), monoethanolamine (MEA) and diglycolamine (DGA) solutions.

  13. Accurate thickness measurement of graphene

    NASA Astrophysics Data System (ADS)

    Shearer, Cameron J.; Slattery, Ashley D.; Stapleton, Andrew J.; Shapter, Joseph G.; Gibson, Christopher T.

    2016-03-01

    Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1-1.3 nm to 0.1-0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials.

  14. Tomographic diagnostics of nonthermal plasmas

    NASA Astrophysics Data System (ADS)

    Denisova, Natalia

    2009-10-01

    In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.

  15. Quantified diagnostic work-up casts: applications for interdisciplinary treatment planning.

    PubMed

    Solow, Roger A

    2016-01-01

    Diagnostic casts that accurately replicate a patient's occlusion are essential for planning comprehensive care and interdisciplinary treatment. These casts can reveal the actual problem in the spatial relationship between the maxilla and the mandible, which may not be apparent on intraoral examination. Duplicate casts can be altered and measured to quantify the extent of the correction necessary for a predictable result. Treatment planning for interdisciplinary cases requires thorough evaluation of the entire problem and solution set as well as coordination of all procedures. Severe problems and invasive treatments require precise treatment planning. This case report illustrates these principles through multiple applications of quantified diagnostic work-up casts for a patient requiring orthognathic surgery, orthodontics, and occlusal adjustment after a mandibular subcondylar fracture. PMID:27148655

  16. Musculoskeletal Aspiration Procedures

    PubMed Central

    Hansford, Barry Glenn; Stacy, Gregory Scott

    2012-01-01

    With advances in imaging technology, there has been a significant increase in the number and range of interventional musculoskeletal image-guided procedures. One of the most commonly performed image-guided musculoskeletal interventions is the diagnostic and therapeutic percutaneous aspiration and drainage of multiple types of intra-articular, juxta-articular, and intramuscular pathologic fluid collections. These procedures may be performed under fluoroscopic, ultrasound, computed tomography, or even magnetic resonance guidance depending on the location to be accessed, type of pathology, patient characteristics, and operator preference. Musculoskeletal image-guided aspiration and drainage procedures are minimally invasive and generally very safe while offering valuable diagnostic information as well as therapeutic benefit. This article focuses on the appropriate indications, contraindications, and general technique for accessing the major joints via imaging guidance. For each joint, we discuss pertinent anatomy, appropriate imaging modalities, and preferred approaches to gaining intra-articular access. Additionally, the article discusses some of the more frequently encountered juxta-articular and intramuscular fluid collections that can be accessed and aspirated via percutaneous intervention, with mention of the importance of recognizing extremity sarcomas that can mimic these benign collections. PMID:24293800

  17. Accurate simulation of optical properties in dyes.

    PubMed

    Jacquemin, Denis; Perpète, Eric A; Ciofini, Ilaria; Adamo, Carlo

    2009-02-17

    Since Antiquity, humans have produced and commercialized dyes. To this day, extraction of natural dyes often requires lengthy and costly procedures. In the 19th century, global markets and new industrial products drove a significant effort to synthesize artificial dyes, characterized by low production costs, huge quantities, and new optical properties (colors). Dyes that encompass classes of molecules absorbing in the UV-visible part of the electromagnetic spectrum now have a wider range of applications, including coloring (textiles, food, paintings), energy production (photovoltaic cells, OLEDs), or pharmaceuticals (diagnostics, drugs). Parallel to the growth in dye applications, researchers have increased their efforts to design and synthesize new dyes to customize absorption and emission properties. In particular, dyes containing one or more metallic centers allow for the construction of fairly sophisticated systems capable of selectively reacting to light of a given wavelength and behaving as molecular devices (photochemical molecular devices, PMDs).Theoretical tools able to predict and interpret the excited-state properties of organic and inorganic dyes allow for an efficient screening of photochemical centers. In this Account, we report recent developments defining a quantitative ab initio protocol (based on time-dependent density functional theory) for modeling dye spectral properties. In particular, we discuss the importance of several parameters, such as the methods used for electronic structure calculations, solvent effects, and statistical treatments. In addition, we illustrate the performance of such simulation tools through case studies. We also comment on current weak points of these methods and ways to improve them. PMID:19113946

  18. Procedural learning and dyslexia.

    PubMed

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken. PMID:20680991

  19. PHOTOCHEMICAL URBAN AIRSHED MODELING USING DIAGNOSTIC AND DYNAMIC METEOROLOGICAL FIELDS

    EPA Science Inventory

    Spatial pollutant patterns and peak concentrations are strongly influenced by meteorological parameters. herefore, accurate hourly, gridded meteorological data sets are crucial inputs for photochemical modeling. n effort has been underway to apply both diagnostic and dynamic mete...

  20. Echocardiographic Imaging of Procedural Complications During Balloon-Expandable Transcatheter Aortic Valve Replacement

    PubMed Central

    Hahn, Rebecca T.; Kodali, Susheel; Tuzcu, E. Murat; Leon, Martin B.; Kapadia, Samir; Gopal, Deepika; Lerakis, Stamatios; Lindman, Brian R.; Wang, Zuyue; Webb, John; Thourani, Vinod H.; Douglas, Pamela S.

    2015-01-01

    Transcatheter aortic valve replacement (TAVR) using a balloon-expandable valve is an accepted alternative to surgical replacement for severe, symptomatic aortic stenosis in high risk or inoperable patients. Intraprocedural transesophageal echocardiography (TEE) offers real-time imaging guidance throughout the procedure and allows for rapid and accurate assessment of complications and procedural results. The value of intraprocedural TEE for TAVR will likely increase in the future as this procedure is performed in lower surgical risk patients, who also have lower risk for general anesthesia, but a greater expectation of optimal results with lower morbidity and mortality. This imaging compendium from the PARTNER (Placement of Aortic Transcatheter Valves) trials is intended to be a comprehensive compilation of intraprocedural complications imaged by intraprocedural TEE and diagnostic tools to anticipate and/or prevent their occurrence. PMID:25772835

  1. Accurate ab Initio Spin Densities

    PubMed Central

    2012-01-01

    We present an approach for the calculation of spin density distributions for molecules that require very large active spaces for a qualitatively correct description of their electronic structure. Our approach is based on the density-matrix renormalization group (DMRG) algorithm to calculate the spin density matrix elements as a basic quantity for the spatially resolved spin density distribution. The spin density matrix elements are directly determined from the second-quantized elementary operators optimized by the DMRG algorithm. As an analytic convergence criterion for the spin density distribution, we employ our recently developed sampling-reconstruction scheme [J. Chem. Phys.2011, 134, 224101] to build an accurate complete-active-space configuration-interaction (CASCI) wave function from the optimized matrix product states. The spin density matrix elements can then also be determined as an expectation value employing the reconstructed wave function expansion. Furthermore, the explicit reconstruction of a CASCI-type wave function provides insight into chemically interesting features of the molecule under study such as the distribution of α and β electrons in terms of Slater determinants, CI coefficients, and natural orbitals. The methodology is applied to an iron nitrosyl complex which we have identified as a challenging system for standard approaches [J. Chem. Theory Comput.2011, 7, 2740]. PMID:22707921

  2. 40 CFR 1060.505 - Other procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equivalent to allowed procedures or are more accurate or more precise than allowed procedures. See 40 CFR... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Other procedures. 1060.505 Section 1060.505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION...

  3. Quantitative MRI as a diagnostic tool of intervertebral disc matrix composition and integrity

    PubMed Central

    Mwale, Fackson; Iatridis, James C.

    2008-01-01

    Degenerative disc disease has been implicated as a major component of spine pathology. The current major clinical procedures for treating disc degeneration have been disappointing, because of altered spinal mechanics leading to subsequent degeneration at adjacent disc levels. Disc pathology treatment is shifting toward prevention and treatment of underlying etiologic processes at the level of the disc matrix composition and integrity and the biomechanics of the disc. The ability to perform such treatment relies on one’s ability to accurately and objectively assess the state of the matrix and the effectiveness of treatment by a non-invasive technique. In this review, we will summarize our advances in efforts to develop an objective, accurate, non-invasive diagnostic tool (quantitative MRI) in the detection and quantification of matrix composition and integrity and of biomechanical changes in early intervertebral disc degeneration. PMID:19005703

  4. Huntington Disease: Molecular Diagnostics Approach.

    PubMed

    Bastepe, Murat; Xin, Winnie

    2015-01-01

    Huntington disease (HD) is caused by expansion of a CAG trinucleotide repeat in the first exon of the Huntingtin (HTT) gene. Molecular testing of Huntington disease for diagnostic confirmation and disease prediction requires detection of the CAG repeat expansion. There are three main types of HD genetic testing: (1) diagnostic testing to confirm or rule out disease, (2) presymptomatic testing to determine whether an at-risk individual inherited the expanded allele, and (3) prenatal testing to determine whether the fetus has inherited the expanded allele. This unit includes protocols that describe the complementary use of polymerase chain reactions (PCR) and Southern blot hybridization to accurately measure the CAG trinucleotide repeat size and interpret the test results. In addition, an indirect linkage analysis that does not reveal the unwanted parental HD status in a prenatal testing will also be discussed. PMID:26439718

  5. Nucleic acid probes in diagnostic medicine

    NASA Technical Reports Server (NTRS)

    Oberry, Phillip A.

    1991-01-01

    The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.

  6. Single molecule detection for in vitro diagnostics

    NASA Astrophysics Data System (ADS)

    Kirner, Thomas; Ackermann, Jörg; Mathis, Harald P.; Greiner, Benjamin; Tonn, Thomas; Tschachojan, David; Kukoc-Zivojnov, Natasa; Giehring, Sebastian

    2008-02-01

    In this paper we present a novel highly sensitive detection system for diagnostic applications. The system is designed to meet the needs of medical diagnostics for reliable measurements of pathogens and biomarkers in the low concentration regime. It consists of a confocal detection unit, micro-structured sampling cells, and a "Virtual lab" analysis software. The detection unit works with laser induced fluorescence and is designed to provide accurate and highly sensitive measurement at the single molecule level. Various sampling cells are micro-structured in glass, silicon or polymers to enable measurements under flow and nonflow conditions. Sampling volume is below one microliter. The "Virtual lab" software analyzes the light intensity online according to the patent pending "Accurate Stochastic Fluorescence Spectroscopy" (ASFS) developed by FluIT Biosystems GmbH. Tools for simulation and experiment optimization are included as well. Experimental results for various applications with relevance for in vitro diagnostics will be presented.

  7. A Framework to Debug Diagnostic Matrices

    NASA Technical Reports Server (NTRS)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  8. MEMS accelerometers in accurate mount positioning systems

    NASA Astrophysics Data System (ADS)

    Mészáros, László; Pál, András.; Jaskó, Attila

    2014-07-01

    In order to attain precise, accurate and stateless positioning of telescope mounts we apply microelectromechanical accelerometer systems (also known as MEMS accelerometers). In common practice, feedback from the mount position is provided by electronic, optical or magneto-mechanical systems or via real-time astrometric solution based on the acquired images. Hence, MEMS-based systems are completely independent from these mechanisms. Our goal is to investigate the advantages and challenges of applying such devices and to reach the sub-arcminute range { that is well smaller than the field-of-view of conventional imaging telescope systems. We present how this sub-arcminute accuracy can be achieved with very cheap MEMS sensors. Basically, these sensors yield raw output within an accuracy of a few degrees. We show what kind of calibration procedures could exploit spherical and cylindrical constraints between accelerometer output channels in order to achieve the previously mentioned accuracy level. We also demonstrate how can our implementation be inserted in a telescope control system. Although this attainable precision is less than both the resolution of telescope mount drive mechanics and the accuracy of astrometric solutions, the independent nature of attitude determination could significantly increase the reliability of autonomous or remotely operated astronomical observations.

  9. Optical Diagnostics in Medicine

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor

    2003-03-01

    Light has a unique potential for non-invasive tissue diagnosis. The relatively short wavelength of light allows imaging of tissue at the resolution of histopathology. While strong multiple scattering of light in tissue makes attainment of this resolution difficult for thick tissues, most pathology emanates from epithelial surfaces. Therefore, high-resolution diagnosis of many important diseases may be achieved by transmitting light to the surface of interest. The recent fiber-optic implementation of technologies that reject multiple scattering, such as confocal microscopy and optical low coherence interferometry, have brought us one step closer to realizing non-invasive imaging of architectural and cellular features of tissue. Optical coherence tomography (OCT) can produce high-resolution cross-sectional images of biological structures. Clinical OCT studies conducted in the gastrointestinal tract and cardiovascular system have shown that OCT is capable of providing images of the architectural (> 20 µm) microanatomy of a variety of epithelial tissues, including the layered structure of squamous epithelium and arterial vessels. Fine Needle Aspiration- Low Coherence Interferometry (FNA-LCI) is another optical diagnostics technique, which is a suitable solution to increase the effectiveness of the FNA procedures. LCI is capable of measuring depth resolved (axial, z) tissue structure, birefringence, flow (Doppler shift), and spectra at a resolution of several microns. Since LCI systems are fiber-optic based, LCI probes may easily fit within the bore of a fine gauge needle, allowing diagnostic information to be obtained directly from the FNA biopsy site. Fiber optic spectrally encoded confocal microscopy (SECM) is a new confocal microscopy method, which eliminates the need for rapid beam scanning within the optical probe. This advance enables confocal microscopy to be performed through small diameter probes and will allow assessment of internal human tissues in vivo at

  10. Medical thoracoscopy: Analysis on diagnostic yield through 30 years of experience

    PubMed Central

    Valsecchi, Alberto; Arondi, Sabrina; Marchetti, Giampietro

    2016-01-01

    BACKGROUND: Medical thoracoscopy (MT) or pleuroscopy is a procedure performed to diagnose and treat malignant and benign pleural diseases. Totally 2752 pleuroscopies executed in 1984–2013 in our center were considered in this study. METHODS: A retrospective observational study was performed. Observational time was divided into six series of 5 years. We calculated MT diagnostic yield and analyzed trends of main diseases diagnosed along the time. RESULTS: Along the 30 years population became progressively older. Number of pleuroscopies firstly increased, then stabilized and decreased in the last 5 years. The overall diagnostic yield of MT was 71%, increasing from 57% to 79%. The diagnostic yield was significantly higher in the presence of monolateral pleural effusion. Cancer represented more than half of diagnosis; tuberculosis was the most common nonneoplastic disease. The frequency of all cancers, mesothelioma, and lung cancer increased through the time; tuberculosis first decreased and then increased. All specimens resulted appropriate during the last 25 years. CONCLUSION: MT has a great diagnostic yield that can be improved by practice, permitting to achieve a specific histological diagnosis in about 80% of patients. Our experience demonstrates that the accurate selection of the patients undergoing to MT is very important to reach these results. PMID:27512506

  11. Gonorrhoea diagnostics: An update.

    PubMed

    Verma, R; Sood, S

    2016-01-01

    Diagnosis of gonorrhoea is an ongoing challenge. The organism is fastidious requiring meticulous collection and transport for successful cultivation. Asymptomatic infections are common which go undetected by conventional methods thereby leading to continued transmission and the risk of complications. The nucleic acid amplification tests, now increasingly used in developed countries, offer improved sensitivity compared to bacterial culture. However, these continue to suffer sequence related problems leading to false positive and false negative results. Further, these cannot be used for generation of data on antibiotic susceptibility because genetic markers of antibiotic resistance to recommended therapies have not been fully characterised. They are unaffordable in a setting like ours where reliance is placed on syndromic approach for sexually transmitted infection (STI) management. The use of syndromic approach has resulted in a considerable decline in the number of Neisseria gonorrhoeae isolates that have been cultured for diagnostic purposes. Many laboratories formerly doing so are no longer performing culture for gonococci, and the basic skills have been lost. There is a need to not only revive this skill but also adopt newer technologies that can aid in accurate diagnosis in a cost-effective manner. There is room for innovation that can facilitate the development of a point-of-care test for this bacterial STI. PMID:27080763

  12. Multigrid time-accurate integration of Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Arnone, Andrea; Liou, Meng-Sing; Povinelli, Louis A.

    1993-01-01

    Efficient acceleration techniques typical of explicit steady-state solvers are extended to time-accurate calculations. Stability restrictions are greatly reduced by means of a fully implicit time discretization. A four-stage Runge-Kutta scheme with local time stepping, residual smoothing, and multigridding is used instead of traditional time-expensive factorizations. Some applications to natural and forced unsteady viscous flows show the capability of the procedure.

  13. Surgical Procedures. Second Edition. Teacher Edition.

    ERIC Educational Resources Information Center

    Baker, Beverly; And Others

    This teacher's guide contains 13 units of instruction for a course that will prepare students with the entry-level competencies needed by a surgical technologist. The course covers the following topics: introduction to surgical procedures; diagnostic procedures; general surgery; gastrointestinal surgery; obstetrics and gynecological surgery;…

  14. Optoelectronic pantography diagnostics of temporomandibular disorders in patients with bruxism.

    PubMed

    Mehulić, Ketij; Gospić, Renata Kevilj; Dundjer, Alenko; Skrinjarić, Tomislav; Stefancić, Sanja; Vojvodić, Denis; Perinić, Margareta

    2009-09-01

    Temporomandibular disorders (TMD) is a joint term that encompasses a number of clinical symptoms that involve the teeth, masticatory musculature and temporomandibular joints (TMJ). They are a frequent cause of orofacial medical conditions. The aetiology of disorders is complex and individual etiologic factors are not sufficiently defined. Bruxism, in its centric or eccentric form, is becoming a frequent problem for dentists. The purpose of this study is to show factors of the condyle leading in patients with bruxism by optoelectronic pantography, and to establish the possibility of using optoelectronic pantography in the diagnostic procedure of TMD. Patients were selected (N = 42), with incomplete sets of teeth, without prosthodontic appliances and with traces and symptoms of TMD. After completing the history questionnaire a clinical check up and plaster cast analysis patients with bruxism were selected (N = 22) and without bruxism (N = 20). During the study optoelectronic String-condylocomp LR3, Dentron, D-Höchberg (software JAWS 30) was used. This study showed the possibility of applying optoelectronic pantography in TMD diagnostics and compares history, clinical and condylographic parameters in TMD patients with and without bruxism. Optoelectronic pantography enables us, by using relatively easy methods, to determine a more accurate diagnosis, highly important when choosing therapeutic methods and control of the aforementioned disorders. PMID:19860114

  15. Production Pathways and Separation Procedures for High-Diagnostic-Value Activation Species, Fission Products, and Actinides Required for Preparation of Realistic Synthetic Post-Detonation Nuclear Debris: Status Report and FY16 Project Plan

    SciTech Connect

    Faye, S. A.; Shaughnessy, D. A.

    2015-08-19

    The objective of this project is to provide a comprehensive study on the production routes and chemical separation requirements for activation products, fission products, and actinides required for the creation of realistic post-detonation surrogate debris. Isotopes that have been prioritized by debris diagnosticians will be examined for their ability to be produced at existing irradiation sources, production rates, and availability of target materials, and chemical separation procedures required to rapidly remove the products from the bulk target matrix for subsequent addition into synthetic debris samples. The characteristics and implications of the irradiation facilities on the isotopes of interest will be addressed in addition to a summary of the isotopes that are already regularly produced. This is a planning document only.

  16. R&D ERL: Diagnostics

    SciTech Connect

    Gassner, D.

    2010-01-01

    The Energy Recovery Linac (ERL) prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This report outlines requirements on the ERL diagnostics and describes its setup and modes of operation. The BNL Prototype ERL is an R&D effort aimed at reducing risks and costs associated with the proposed RHIC II electron cooler and eRHIC collider. The ERL will serve as a test bed for developing and testing instrumentation and studying physics and technological issues relevant to very high current ERL's. The prototype ERL, mated to a high current SRF gun, is expected to demonstrate production and energy recovery of high intensity, low emittance beams with a current of up to a few hundred milliamps. To successfully accomplish this task the ERL will include beam diagnostics required to characterize and tune beam parameters, as well as for machine protection. A preliminary diagnostics plan was presented in earlier publications. In this report, we describe the diagnostics presently planned to provide the data needed to meet these goals.

  17. Application of Statistics in Establishing Diagnostic Certainty

    PubMed Central

    Denegar, Craig R.; Cordova, Mitchell L.

    2012-01-01

    The examination and assessment of injured and ill patients leads to the establishment of a diagnosis. However, the tests and procedures used in health care, including procedures performed by certified athletic trainers, are individually and collectively imperfect in confirming or ruling out a condition of concern. Thus, research into the utility of diagnostic tests is needed to identify the procedures that are most helpful and to indicate the confidence one should place in the results of the test. The purpose of this report is to provide an overview of selected statistical procedures and the interpretation of data appropriate for assessing the utility of diagnostic tests with dichotomous (positive or negative) outcomes, with particular attention to the interpretation of sensitivity and specificity estimates and the reporting of confidence intervals around likelihood ratio estimates. PMID:22488292

  18. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  19. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  20. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  1. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  2. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  3. Dental Procedures.

    PubMed

    Ramponi, Denise R

    2016-01-01

    Dental problems are a common complaint in emergency departments in the United States. There are a wide variety of dental issues addressed in emergency department visits such as dental caries, loose teeth, dental trauma, gingival infections, and dry socket syndrome. Review of the most common dental blocks and dental procedures will allow the practitioner the opportunity to make the patient more comfortable and reduce the amount of analgesia the patient will need upon discharge. Familiarity with the dental equipment, tooth, and mouth anatomy will help prepare the practitioner for to perform these dental procedures. PMID:27482994

  4. Evaluating a Dental Diagnostic Terminology in an Electronic Health Record

    PubMed Central

    White, Joel M.; Kalenderian, Elsbeth; Stark, Paul C.; Ramoni, Rachel L.; Vaderhobli, Ram; Walji, Muhammad F.

    2011-01-01

    Standardized treatment procedure codes and terms are routinely used in dentistry. Utilization of a diagnostic terminology is common in medicine, but there is not a satisfactory or commonly standardized dental diagnostic terminology available at this time. Recent advances in dental informatics have provided an opportunity for inclusion of diagnostic codes and terms as part of treatment planning and documentation in the patient treatment history. This article reports the results of the use of a diagnostic coding system in a large dental school’s predoctoral clinical practice. A list of diagnostic codes and terms, called Z codes, was developed by dental faculty members. The diagnostic codes and terms were implemented into an electronic health record (EHR) for use in a predoctoral dental clinic. The utilization of diagnostic terms was quantified. The validity of Z code entry was evaluated by comparing the diagnostic term entered to the procedure performed, where valid diagnosis-procedure associations were determined by consensus among three calibrated academically based dentists. A total of 115,004 dental procedures were entered into the EHR during the year sampled. Of those, 43,053 were excluded from this analysis because they represent diagnosis or other procedures unrelated to treatments. Among the 71,951 treatment procedures, 27,973 had diagnoses assigned to them with an overall utilization of 38.9 percent. Of the 147 available Z codes, ninety-three were used (63.3 percent). There were 335 unique procedures provided and 2,127 procedure/diagnosis pairs captured in the EHR. Overall, 76.7 percent of the diagnoses entered were valid. We conclude that dental diagnostic terminology can be incorporated within an electronic health record and utilized in an academic clinical environment. Challenges remain in the development of terms and implementation and ease of use that, if resolved, would improve the utilization. PMID:21546594

  5. Diagnostic Algorithm Benchmarking

    NASA Technical Reports Server (NTRS)

    Poll, Scott

    2011-01-01

    A poster for the NASA Aviation Safety Program Annual Technical Meeting. It describes empirical benchmarking on diagnostic algorithms using data from the ADAPT Electrical Power System testbed and a diagnostic software framework.

  6. Tissue resonance interaction accurately detects colon lesions: A double-blind pilot study

    PubMed Central

    Dore, Maria P; Tufano, Marcello O; Pes, Giovanni M; Cuccu, Marianna; Farina, Valentina; Manca, Alessandra; Graham, David Y

    2015-01-01

    AIM: To investigated the performance of the tissue resonance interaction method (TRIM) for the non-invasive detection of colon lesions. METHODS: We performed a prospective single-center blinded pilot study of consecutive adults undergoing colonoscopy at the University Hospital in Sassari, Italy. Before patients underwent colonoscopy, they were examined by the TRIMprobe which detects differences in electromagnetic properties between pathological and normal tissues. All patients had completed the polyethylene glycol-containing bowel prep for the colonoscopy procedure before being screened. During the procedure the subjects remained fully dressed. A hand-held probe was moved over the abdomen and variations in electromagnetic signals were recorded for 3 spectral lines (462-465 MHz, 930 MHz, and 1395 MHz). A single investigator, blind to any clinical information, performed the test using the TRIMprob system. Abnormal signals were identified and recorded as malignant or benign (adenoma or hyperplastic polyps). Findings were compared with those from colonoscopy with histologic confirmation. Statistical analysis was performed by χ2 test. RESULTS: A total of 305 consecutive patients fulfilling the inclusion criteria were enrolled over a period of 12 months. The most frequent indication for colonoscopy was abdominal pain (33%). The TRIMprob was well accepted by all patients; none spontaneously complained about the procedure, and no adverse effects were observed. TRIM proved inaccurate for polyp detection in patients with inflammatory bowel disease (IBD) and they were excluded leaving 281 subjects (mean age 59 ± 13 years; 107 males). The TRIM detected and accurately characterized all 12 adenocarcinomas and 135/137 polyps (98.5%) including 64 adenomatous (100%) found. The method identified cancers and polyps with 98.7% sensitivity, 96.2% specificity, and 97.5% diagnostic accuracy, compared to colonoscopy and histology analyses. The positive predictive value was 96.7% and the

  7. ISHM-oriented adaptive fault diagnostics for avionics based on a distributed intelligent agent system

    NASA Astrophysics Data System (ADS)

    Xu, Jiuping; Zhong, Zhengqiang; Xu, Lei

    2015-10-01

    In this paper, an integrated system health management-oriented adaptive fault diagnostics and model for avionics is proposed. With avionics becoming increasingly complicated, precise and comprehensive avionics fault diagnostics has become an extremely complicated task. For the proposed fault diagnostic system, specific approaches, such as the artificial immune system, the intelligent agents system and the Dempster-Shafer evidence theory, are used to conduct deep fault avionics diagnostics. Through this proposed fault diagnostic system, efficient and accurate diagnostics can be achieved. A numerical example is conducted to apply the proposed hybrid diagnostics to a set of radar transmitters on an avionics system and to illustrate that the proposed system and model have the ability to achieve efficient and accurate fault diagnostics. By analyzing the diagnostic system's feasibility and pragmatics, the advantages of this system are demonstrated.

  8. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Service Act, as implemented by 21 CFR part 900, subpart B. (d) Diagnostic laboratory tests—(1) Who may... required throughout the performance of the test. (i) General supervision means the procedure is furnished... material relevant to the medical necessity of the specific test(s), taking into consideration current...

  9. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... implemented by 21 CFR part 900, subpart B. (d) Diagnostic laboratory tests—(1) Who may furnish services... performance of the test. (i) General supervision means the procedure is furnished under the physician's... necessity of the specific test(s), taking into consideration current rules and regulations on...

  10. Automatic beamline calibration procedures

    SciTech Connect

    Corbett, W.J.; Lee, M.J.; Zambre, Y.

    1992-03-01

    Recent experience with the SLC and SPEAR accelerators have led to a well-defined set of procedures for calibration of the beamline model using the orbit fitting program, RESOLVE. Difference orbit analysis is used to calibrate quadrupole strengths, BPM sensitivities, corrector strengths, focusing effects from insertion devices, and to determine the source of dispersion and coupling errors. Absolute orbit analysis is used to locate quadrupole misalignments, BPM offsets, or beam loss. For light source applications, the photon beam source coordinates can be found. The result is an accurate model of the accelerator which can be used for machine control. In this paper, automatable beamline calibration procedures are outlined and illustrated with recent examples. 5 refs.

  11. Target Diagnostics Supports NIF's Path to Ignition

    SciTech Connect

    Shelton, R

    2011-12-07

    The physics requirements derived from the National Ignition Facility (NIF) experimental campaigns are leading to a wide variety of target diagnostics. Software development for the control and analysis of these diagnostics is included in the NIF Integrated Computer Control System, Diagnostic Control System and Data Visualization. These projects implement the configuration, controls, data analysis and visual representation of most of these diagnostics. To date, over 40 target diagnostics have been developed to support NIF experiments. In 2011 diagnostics were developed or enhanced to measure Ignition performance in a high neutron yield environment. Performance is optimized around four key variables: Adiabat (a) which is the strength and timing of four shocks delivered to the target, Velocity (V) of the imploding target, Mix (M) is the uniformity of the burn, and the Shape (S) of the imploding Deuterium Tritium (DT) hot spot. The diagnostics used to measure each of these parameters is shown in figure 1. Adiabat is measured using the Velocity Interferometer System for Any Reflector (VISAR) diagnostic consisting of three streak cameras. To provide for more accurate adiabat measurements the VISAR streak cameras were enhanced in FY11 with a ten comb fiducial signal controller to allow for post shot correction of the streak camera sweep non-linearity. Mix is measured by the Neutron Time of Flight (NTOF) and Radiochemical Analysis of Gaseous Samples (RAGS) diagnostics. To accommodate high neutron yield shots, NTOF diagnostic controls are being modified to use Mach Zehnder interferometer signals to allow the digitizers to be moved from near the target chamber to the neutron shielded diagnostic mezzanine. In December 2011 the first phase of RAGS diagnostic commissioning will be completed. This diagnostic will analyze the tracers that are added to NIF target capsules that undergo nuclear reactions during the shot. These gases are collected and purified for nuclear counting by

  12. Ultrasound-Guided Peripheral Nerve Procedures.

    PubMed

    Strakowski, Jeffrey A

    2016-08-01

    Ultrasound guidance allows real-time visualization of the needle in peripheral nerve procedures, improving accuracy and safety. Sonographic visualization of the peripheral nerve and surrounding anatomy can provide valuable information for diagnostic purposes and procedure enhancement. Common procedures discussed are the suprascapular nerve at the suprascapular notch, deep branch of the radial nerve at the supinator, median nerve at the pronator teres and carpal tunnel, lateral cutaneous nerve of the thigh, superficial fibular nerve at the leg, tibial nerve at the ankle, and interdigital neuroma. For each procedure, the indications, relevant anatomy, preprocedural scanning technique, and injection procedure itself are detailed. PMID:27468673

  13. High Energy Laser Diagnostic Sensors

    NASA Astrophysics Data System (ADS)

    Luke, James R.; Goddard, Douglas N.; Lewis, Jay; Thomas, David

    2010-10-01

    Recent advancements in high energy laser (HEL) sources have outpaced diagnostic tools capable of accurately quantifying system performance. Diagnostic tools are needed that allow system developers to measure the parameters that define HEL effectiveness. The two critical parameters for quantifying HEL effectiveness are the irradiance on target and resultant rise in target temperature. Off-board sensing has its limitations, including unpredictable changes in the reflectivity of the target, smoke and outgassing, and atmospheric distortion. On-board sensors overcome the limitations of off-board techniques but must survive high irradiance levels and extreme temperatures. We have developed sensors for on-target diagnostics of high energy laser beams and for the measurement of the thermal response of the target. The conformal sensors consist of an array of quantum dot photodetectors and resistive temperature detectors. The sensor arrays are lithographically fabricated on flexible substrates and can be attached to a variety of laser targets. We have developed a nanoparticle adhesive process that provides good thermal contact with the target and that ensures the sensor remains attached to the target for as long as the target survives. We have calibrated the temperature and irradiance sensors and demonstrated them in a HEL environment.

  14. Diagnostics for Fast Ignition Science

    SciTech Connect

    MacPhee, A; Akli, K; Beg, F; Chen, C; Chen, H; Clarke, R; Hey, D; Freeman, R; Kemp, A; Key, M; King, J; LePape, S; Link, A; Ma, T; Nakamura, N; Offermann, D; Ovchinnikov, V; Patel, P; Phillips, T; Stephens, R; Town, R; Wei, M; VanWoerkom, L; Mackinnon, A

    2008-05-06

    The concept for Electron Fast Ignition Inertial Confinement Fusion demands sufficient laser energy be transferred from the ignitor pulse to the assembled fuel core via {approx}MeV electrons. We have assembled a suite of diagnostics to characterize such transfer. Recent experiments have simultaneously fielded absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256eV; spherically bent crystal imagers at 4 and 8keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung and electron and proton spectrometers (along the same line of sight); nuclear activation samples and a picosecond optical probe based interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following laser-plasma interactions at extremely high intensities in both planar and conical targets. Augmented with accurate on-shot laser focal spot and pre-pulse characterization, these measurements are yielding new insight into energy coupling and are providing critical data for validating numerical PIC and hybrid PIC simulation codes in an area that is crucial for many applications, particularly fast ignition. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultra high intensity laser plasma interactions are discussed, together with implications for full-scale fast ignition experiments.

  15. Accurate orbit propagation with planetary close encounters

    NASA Astrophysics Data System (ADS)

    Baù, Giulio; Milani Comparetti, Andrea; Guerra, Francesca

    2015-08-01

    We tackle the problem of accurately propagating the motion of those small bodies that undergo close approaches with a planet. The literature is lacking on this topic and the reliability of the numerical results is not sufficiently discussed. The high-frequency components of the perturbation generated by a close encounter makes the propagation particularly challenging both from the point of view of the dynamical stability of the formulation and the numerical stability of the integrator. In our approach a fixed step-size and order multistep integrator is combined with a regularized formulation of the perturbed two-body problem. When the propagated object enters the region of influence of a celestial body, the latter becomes the new primary body of attraction. Moreover, the formulation and the step-size will also be changed if necessary. We present: 1) the restarter procedure applied to the multistep integrator whenever the primary body is changed; 2) new analytical formulae for setting the step-size (given the order of the multistep, formulation and initial osculating orbit) in order to control the accumulation of the local truncation error and guarantee the numerical stability during the propagation; 3) a new definition of the region of influence in the phase space. We test the propagator with some real asteroids subject to the gravitational attraction of the planets, the Yarkovsky and relativistic perturbations. Our goal is to show that the proposed approach improves the performance of both the propagator implemented in the OrbFit software package (which is currently used by the NEODyS service) and of the propagator represented by a variable step-size and order multistep method combined with Cowell's formulation (i.e. direct integration of position and velocity in either the physical or a fictitious time).

  16. Writer's Guide for technical procedures

    SciTech Connect

    Not Available

    1991-09-01

    A primary objective throughout the Department of Energy (DOE) complex is that operations be conducted in a deliberate and controlled manner with emphasis upon recognition and maintenance of the facility-specific safety envelope. One critical element of maintaining the safety envelope is procedures. DOE is providing guidance through this and other writer's guides to assist procedure writers across the DOE complex in producing accurate, complete, and usable procedures that promote safe and efficient operations in keeping with such DOE Orders as 5480.19, Conduct of Operations for DOE Facilities'', 5480.5, Safety of Nuclear facilities'', and 5480.6, Safety of Department of Energy-Owned Nuclear Reactors''. This Writer's Guide addresses the content, format, and style of technical procedures (procedures that prescribe production, operation of equipment and facilities, and maintenance activities) and is intended to be applied in a manner appropriate to the individual facility, 15 refs.

  17. Procedural simulation.

    PubMed

    Patel, Aalpen A; Glaiberman, Craig; Gould, Derek A

    2007-06-01

    In the past few decades, medicine has started to look at the potential use of simulators in medical education. Procedural medicine lends itself well to the use of simulators. Efforts are under way to establish national agendas to change the way medical education is approached and thereby improve patient safety. Universities, credentialing organizations, and hospitals are investing large sums of money to build and use simulation centers for undergraduate and graduate medical education. PMID:17574195

  18. Microfluidic diagnostic technologies for global public health

    NASA Astrophysics Data System (ADS)

    Yager, Paul; Edwards, Thayne; Fu, Elain; Helton, Kristen; Nelson, Kjell; Tam, Milton R.; Weigl, Bernhard H.

    2006-07-01

    The developing world does not have access to many of the best medical diagnostic technologies; they were designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. Microfluidic systems allow miniaturization and integration of complex functions, which could move sophisticated diagnostic tools out of the developed-world laboratory. These systems must be inexpensive, but also accurate, reliable, rugged and well suited to the medical and social contexts of the developing world.

  19. School Before Six: A Diagnostic Approach. Volume I (Revised Edition).

    ERIC Educational Resources Information Center

    Hodgden, Laurel; And Others

    Specific procedures for assessing young children's strengths and learning needs are described in this first volume of a 2-volume manual which describes a diagnostic method of teaching preschool children. An overall introduction to the manual is followed by Chapter 2, which presents the philosophical framework of the diagnostic approach and…

  20. Endoscopic diagnostic of chronic pancreatitis.

    PubMed

    Cubranić, Aleksandar; Dintinjana, Renata Dobrila; Vanis, Nenad

    2014-12-01

    Chronic pancreatitis is defined as a continuous inflammatory pancreatic disease, one characterized by irreversible morphological changes, often associates with pain and sometimes with the loss of endocrine and exocrine function. As a histological confirmation of chronic pancreatitis is often unavailable, the diagnosis is traditionally based on imaging methods such as computerized tomography (CT) or endoscopic retrograde cholangiopancreatography (ERCP), and recently magnetic resonance cholangiopancreatography (MRCP) as a noninvasive alternative to ERCP. Developments in the classification system of CP include the Marseille classification of 1963 which offered histopathologic criteria for CP, the Cambridge classification of 1984 which introduced imaging features of computed tomography (CT), transabdominal ultrasound (TUS) and endoscopic retrograde cholangiopancreatography (ERCP) for classification of CP as well as Rosemont classification system of 2007 which presented the endoscopic ultrasonography diagnosis of CP. Endoscopic ultra-sonography (EUS) was first introduced as a diagnostic method for evaluation of pancreatic disease in 1986. It has experienced significant improvements since then and allowed for an alternative approach in diagnosing patients with pancreatic diseases. In patients with suspected pancreatic masses EUS-guided fine needle aspiration (EUS-FNA) is the best method for obtaining tissue diagnosis and differentiating CP from pancreatic carcinoma. The recent studies indicate that EUS is the method of choice when compared with other imaging methods such as ERCP because it frequently provides more accurate diagnostics. The aim of this review is to discuss the findings in endoscopic diagnostics up to the present moment and to indicate advantages, limitations and possible complications along with the current recommendations in CP diagnostics. PMID:25842773

  1. Accurate and Precise Zinc Isotope Ratio Measurements in Urban Aerosols

    NASA Astrophysics Data System (ADS)

    Weiss, D.; Gioia, S. M. C. L.; Coles, B.; Arnold, T.; Babinski, M.

    2009-04-01

    We developed an analytical method and constrained procedural boundary conditions that enable accurate and precise Zn isotope ratio measurements in urban aerosols. We also demonstrate the potential of this new isotope system for air pollutant source tracing. The procedural blank is around 5 ng and significantly lower than published methods due to a tailored ion chromatographic separation. Accurate mass bias correction using external correction with Cu is limited to Zn sample content of approximately 50 ng due to the combined effect of blank contribution of Cu and Zn from the ion exchange procedure and the need to maintain a Cu/Zn ratio of approximately 1. Mass bias is corrected for by applying the common analyte internal standardization method approach. Comparison with other mass bias correction methods demonstrates the accuracy of the method. The average precision of δ66Zn determinations in aerosols is around 0.05 per mil per atomic mass unit. The method was tested on aerosols collected in Sao Paulo City, Brazil. The measurements reveal significant variations in δ66Zn ranging between -0.96 and -0.37 per mil in coarse and between -1.04 and 0.02 per mil in fine particular matter. This variability suggests that Zn isotopic compositions distinguish atmospheric sources. The isotopic light signature suggests traffic as the main source.

  2. Genetic Diagnostic Methods for Inherited Eye Diseases

    PubMed Central

    Gabriel, Luis A. R.; Traboulsi, Elias I.

    2011-01-01

    Accurate molecular diagnosis of genetic eye diseases has proven to be of great importance because of the prognostic and therapeutic value of an accurate ascertainment of the underlying genetic mutation. Efforts continue in diagnostic laboratories to develop strategies that allow the discovery of responsible gene/mutations in the individual patient using the least number of assays and economizing on the expenses and time involved in the process. Once the ophthalmologist has made the best possible clinical diagnosis, blood samples are obtained for genetic testing. In this paper we will review the basic laboratory methods utilized to identify the chromosomal or mutational etiology of genetic diseases that affect the eye. PMID:21572730

  3. TFTR diagnostic vacuum controller

    SciTech Connect

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  4. Diagnostic Development on NSTX

    SciTech Connect

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-12-16

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted.

  5. What Is Diagnostic Testing?

    MedlinePlus

    ... Primary care providers Specialists Getting covered Research Basic science research Research in people ... screening Diagnostic testing Direct-to-consumer genetic testing Newborn screening Pharmacogenomic testing ...

  6. [Diagnostic Errors in Medicine].

    PubMed

    Buser, Claudia; Bankova, Andriyana

    2015-12-01

    The recognition of diagnostic errors in everyday practice can help improve patient safety. The most common diagnostic errors are the cognitive errors, followed by system-related errors and no fault errors. The cognitive errors often result from mental shortcuts, known as heuristics. The rate of cognitive errors can be reduced by a better understanding of heuristics and the use of checklists. The autopsy as a retrospective quality assessment of clinical diagnosis has a crucial role in learning from diagnostic errors. Diagnostic errors occur more often in primary care in comparison to hospital settings. On the other hand, the inpatient errors are more severe than the outpatient errors. PMID:26649954

  7. BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

    SciTech Connect

    R. C. York; X. Wu; Q. Zhao

    2011-12-21

    End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

  8. Bone marrow lesions: A systematic diagnostic approach

    PubMed Central

    Grande, Filippo Del; Farahani, Sahar J; Carrino, John A; Chhabra, Avneesh

    2014-01-01

    Bone marrow lesions on magnetic resonance (MR) imaging are common and may be seen with various pathologies. The authors outline a systematic diagnostic approach with proposed categorization of various etiologies of bone marrow lesions. Utilization of typical imaging features on conventional MR imaging techniques and other problem-solving techniques, such as chemical shift imaging and diffusion-weighted imaging (DWI), to achieve accurate final diagnosis has been highlighted. PMID:25114392

  9. Procedural knowledge

    NASA Technical Reports Server (NTRS)

    Georgeff, Michael P.; Lansky, Amy L.

    1986-01-01

    Much of commonsense knowledge about the real world is in the form of procedures or sequences of actions for achieving particular goals. In this paper, a formalism is presented for representing such knowledge using the notion of process. A declarative semantics for the representation is given, which allows a user to state facts about the effects of doing things in the problem domain of interest. An operational semantics is also provided, which shows how this knowledge can be used to achieve particular goals or to form intentions regarding their achievement. Given both semantics, the formalism additionally serves as an executable specification language suitable for constructing complex systems. A system based on this formalism is described, and examples involving control of an autonomous robot and fault diagnosis for NASA's Space Shuttle are provided.

  10. TFTR diagnostic control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Sauthoff, N. R.; Daniels, R. E.

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  11. TFTR diagnostic control and data acquisition system

    SciTech Connect

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  12. A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome® system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions

    PubMed Central

    Povoski, Stephen P; Jimenez, Rafael E

    2007-01-01

    Background Minimally invasive breast biopsy technology is now considered a standard of care for the diagnostic evaluation of suspicious breast lesions. The aim of the current study was to present a comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome® system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions. Methods A retrospective analysis was conducted of a series of 304 consecutive 8-gauge Mammotome® procedures that were performed under ultrasound guidance by a single surgeon from March 2004 to December 2006. Multiple variables, including patient demographics, characteristics of the breast lesion (based on ultrasound and mammography), procedural and histopathology variables, and interval follow-up variables (based on ultrasound and mammography), were evaluated. Results Among 304 procedures, 235 (77%) were performed with the presumption of complete excision of the ultrasound lesion during Mammotome® core acquisition, while 69 (23%) were performed with only partial excision of the ultrasound lesion during Mammotome® core acquisition (diagnostic tissue sampling only). 100% of all ultrasound lesions were accurately diagnosed, demonstrating no apparent false-negative results among the 256 patients that were compliant with follow-up at a median interval follow-up duration of 11 months (range 1 to 37). Likewise, 89% of all appropriately selected ultrasound lesions were completely excised, as demonstrated on interval follow-up ultrasound at a median time of 6 months (range, 3 to 16). There were no independent predictors of successful complete excision of any given appropriately selected ultrasound lesion by the ultrasound-guided 8-gauge Mammotome® biopsy technique. Conclusion The 8-gauge vacuum-assisted Mammotome® system is highly accurate for ultrasound-guided diagnostic biopsy of suspicious breast lesions and is highly successful for complete excision of appropriately selected presumed benign breast lesions. This

  13. Fast and accurate automated cell boundary determination for fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Arce, Stephen Hugo; Wu, Pei-Hsun; Tseng, Yiider

    2013-07-01

    Detailed measurement of cell phenotype information from digital fluorescence images has the potential to greatly advance biomedicine in various disciplines such as patient diagnostics or drug screening. Yet, the complexity of cell conformations presents a major barrier preventing effective determination of cell boundaries, and introduces measurement error that propagates throughout subsequent assessment of cellular parameters and statistical analysis. State-of-the-art image segmentation techniques that require user-interaction, prolonged computation time and specialized training cannot adequately provide the support for high content platforms, which often sacrifice resolution to foster the speedy collection of massive amounts of cellular data. This work introduces a strategy that allows us to rapidly obtain accurate cell boundaries from digital fluorescent images in an automated format. Hence, this new method has broad applicability to promote biotechnology.

  14. MITG test procedure and results

    SciTech Connect

    Eck, M.B.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper.

  15. Assessment of building diagnostics

    NASA Astrophysics Data System (ADS)

    Courville, G. E.

    1981-07-01

    The building diagnostics requirements for in-situ or field measurements on energy consumption in conditioned spaces and on heat gain and loss in residential and nonresidential buildings are evaluated. Energy audit programs, energy performance monitoring, energy flow in buildings, and use of computer technology are considered. A diagnostics program is outlined.

  16. Automotive Diagnostic Technologies.

    ERIC Educational Resources Information Center

    Columbus State Community Coll., OH.

    This document contains materials developed for and about the automotive diagnostic technologies tech prep program of the South-Western City Schools in Ohio. Part 1 begins with a map of the program, which begins with an automotive/diagnostic technologies program in grades 11 and 12 that leads to entry-level employment or a 2-year automotive…

  17. An overview of control strategy and diagnostic technology for foot-and-mouth disease in China.

    PubMed

    Ding, Yao-Zhong; Chen, Hao-Tai; Zhang, Jie; Zhou, Jian-Hua; Ma, Li-Na; Zhang, Liang; Gu, Yuanxin; Liu, Yong-Sheng

    2013-01-01

    Foot-and-mouth disease (FMD) is one of most contagious animal diseases. It affects millions of cloven-hoofed animals and causes huge economic losses in many countries of the world. There are seven serotypes of which three (O, A and Asia 1) are endemic in China. Efficient control of FMD in China is crucial for the prevention and control of FMD in Asia and throughout the world. For the control of FMD, a powerful veterinary administration, a well-trained veterinary staff, a system of rapid and accurate diagnostic procedures and, in many countries, compulsory vaccination of susceptible animals are indispensable. This article strives to outline the Chinese animal disease control and prevention system, in particular for FMD, with the emphasis on diagnostic procedures applied in Chinese laboratories. In addition, new technologies for FMD diagnosis, which are currently in the phase of development or in the process of validation in Chinese laboratories, are described, such as lateral flow devices (LFD), Mab-based ELISAs, reverse transcription loop-mediated isothermal amplification (RT-LAMP) and gold nanopariticle immuno-PCR (GNP-IPCR). PMID:23497282

  18. [Diagnostic reference levels in interventional radiology].

    PubMed

    Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I

    2013-12-01

    This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. PMID:24211195

  19. Rayleigh Scattering Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard (Compiler)

    1996-01-01

    The Rayleigh Scattering Diagnostics Workshop was held July 25-26, 1995 at the NASA Lewis Research Center in Cleveland, Ohio. The purpose of the workshop was to foster timely exchange of information and expertise acquired by researchers and users of laser based Rayleigh scattering diagnostics for aerospace flow facilities and other applications. This Conference Publication includes the 12 technical presentations and transcriptions of the two panel discussions. The first panel was made up of 'users' of optical diagnostics, mainly in aerospace test facilities, and its purpose was to assess areas of potential applications of Rayleigh scattering diagnostics. The second panel was made up of active researchers in Rayleigh scattering diagnostics, and its purpose was to discuss the direction of future work.

  20. Acquiring, Representing, and Evaluating a Competence Model of Diagnostic Strategy.

    ERIC Educational Resources Information Center

    Clancey, William J.

    This paper describes NEOMYCIN, a computer program that models one physician's diagnostic reasoning within a limited area of medicine. NEOMYCIN's knowledge base and reasoning procedure constitute a model of how human knowledge is organized and how it is used in diagnosis. The hypothesis is tested that such a procedure can be used to simulate both…

  1. Mill profiler machines soft materials accurately

    NASA Technical Reports Server (NTRS)

    Rauschl, J. A.

    1966-01-01

    Mill profiler machines bevels, slots, and grooves in soft materials, such as styrofoam phenolic-filled cores, to any desired thickness. A single operator can accurately control cutting depths in contour or straight line work.

  2. Remote balance weighs accurately amid high radiation

    NASA Technical Reports Server (NTRS)

    Eggenberger, D. N.; Shuck, A. B.

    1969-01-01

    Commercial beam-type balance, modified and outfitted with electronic controls and digital readout, can be remotely controlled for use in high radiation environments. This allows accurate weighing of breeder-reactor fuel pieces when they are radioactively hot.

  3. Interviewing Children Versus Tossing Coins: Accurately Assessing the Diagnosticity of Children’s Disclosures of Abuse

    PubMed Central

    LYON, THOMAS D.; AHERN, ELIZABETH C.; SCURICH, NICHOLAS

    2014-01-01

    We describe a Bayesian approach to evaluating children’s abuse disclosures and review research demonstrating that children’s disclosure of genital touch can be highly probative of sexual abuse, with the probative value depending on disclosure spontaneity and children’s age. We discuss how some commentators understate the probative value of children’s disclosures by: confusing the probability of abuse given disclosure with the probability of disclosure given abuse, assuming that children formally questioned about sexual abuse have a low prior probability of sexual abuse, misstating the probative value of abuse disclosure, and confusing the distinction between disclosure and nondisclosure with the distinction between true and false disclosures. We review interviewing methods that increase the probative value of disclosures, including interview instructions, narrative practice, noncontingent reinforcement, and questions about perpetrator/caregiver statements and children’s reactions to the alleged abuse. PMID:22339423

  4. Interviewing Children versus Tossing Coins: Accurately Assessing the Diagnosticity of Children's Disclosures of Abuse

    ERIC Educational Resources Information Center

    Lyon, Thomas D.; Ahern, Elizabeth C.; Scurich, Nicholas

    2012-01-01

    We describe a Bayesian approach to evaluating children's abuse disclosures and review research demonstrating that children's disclosure of genital touch can be highly probative of sexual abuse, with the probative value depending on disclosure spontaneity and children's age. We discuss how some commentators understate the probative value of…

  5. National NIF Diagnostic Program Interim Management Plan

    SciTech Connect

    Warner, B

    2002-04-25

    The National Ignition Facility (NIF) has the mission of supporting Stockpile Stewardship and Basic Science research in high-energy-density plasmas. To execute those missions, the facility must provide diagnostic instrumentation capable of observing and resolving in time events and radiation emissions characteristic of the plasmas of interest. The diagnostic instrumentation must conform to high standards of operability and reliability within the NIF environment. These exacting standards, together with the facility mission of supporting a diverse user base, has led to the need for a central organization charged with delivering diagnostic capability to the NIF. The National NIF Diagnostics Program (NNDP) has been set up under the aegis of the NIF Director to provide that organization authority and accountability to the wide user community for NIF. The funds necessary to perform the work of developing diagnostics for NIF will be allocated from the National NIF Diagnostics Program to the participating laboratories and organizations. The participating laboratories and organizations will design, build, and commission the diagnostics for NIF. Restricted availability of funding has had an adverse impact, unforeseen at the time of the original decision to projectize NIF Core Diagnostics Systems and Cryogenic Target Handing Systems, on the planning and initiation of these efforts. The purpose of this document is to provide an interim project management plan describing the organizational structure and management processes currently in place for NIF Core Diagnostics Systems. Preparation of a Program Execution Plan for NIF Core Diagnostics Systems has been initiated and a current draft is provided as Attachment 1 to this document. The National NIF Diagnostics Program Interim Management Plan provides a summary of primary design criteria and functional requirements, current organizational structure, tracking and reporting procedures, and current planning estimates of project scope

  6. A biopsymeter to support the diagnostic procedure of skin samples

    NASA Astrophysics Data System (ADS)

    Fioravanti, Valeria; Chandrashekar, Shailendra; Brandhoff, Lukas; Pucciarelli, Daniela; van den Driesche, Sander; Breiteneder, Heimo; Hafner, Christine; Vellekoop, Michael J.

    2015-06-01

    We present an infrared biopsymeter to assist pathologists in the diagnosis of melanoma presence in skin biopsies. The designed and realized system combines the features of visual inspection and physical sensing to reduce false positives and false negatives occurring during standard histopathological analyses. The biopsymeter determines the CH2-stretch ratio by infrared absorbance measurements of skin biopsies. Investigations conducted with the biopsymeter shows that malignant melanomas and melanoma metastases have higher CH2-stretch ratio values compared to healthy skin tissues.

  7. 40 CFR 85.2222 - Onboard diagnostic test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Mode $01, PID $01 request in accordance with 40 CFR 86.1806 to determine the OBD evaluation status. The... evaluation for applicable monitors in accordance with the requirements and specifications in 40 CFR 86.1806... with 40 CFR 86.1806 to determine the stored DTCs. The system shall repeat this cycle until the...

  8. Patient dose measurements in diagnostic radiology procedures in Korea.

    PubMed

    Kim, You-hyun; Choi, Jong-hak; Kim, Chang-kyun; Kim, Jung-min; Kim, Sung-soo; Oh, Yu-whan; Lee, Chang-yeap; Kang, Dae-hyun; Lee, Young-bae; Cho, Pyong-kon; Kim, Hyung-chul; Kim, Chel-min

    2007-01-01

    This study is the first nationwide investigation aimed at estimating the patient dose for radiographic examinations in Korea including gastrointestinal studies, computed tomography and mammography. The survey data from 161 hospitals and the dose data from 32 hospitals were analysed. The third quartile entrance surface dose, dose area product (DAP), weighted CT dose index (CTDIw) and mean glandular dose (MGD) were reported. All the estimated doses were less than the stated International Atomic Energy Agency (IAEA) reference levels for radiographic examinations. However, DAPs for the fluoroscopic examinations had higher dose values than the IAEA reference levels. In addition, the CTDIw and MGD were lower than the IAEA reference levels. PMID:17223642

  9. Diagnostic and therapeutic-restorative procedures for masticatory dysfunctions

    PubMed Central

    Freesmeyer, Wolfgang B.; Fussnegger, M. R.; Ahlers, M. O.

    2005-01-01

    Temporomandibular disorders (TMD) or craniomandibular disorders, respectively, involve diseases of the teeth and periodontia as well as the masticatory muscles, temporomandibular joints and associated structures. It has been shown in recent years that psychological, social and general medical influences are of enormous importance in the etiology of TMD in addition to anatomical, physiological, parafunctional and other biological causes. This signifies that therapists confronted with TMD should already include at an early stage other specialists such as pain therapists, neurologists, ENT physicians, psychotherapists and physiotherapists. Patients need to be referred to dentists specializing in TMD when ENT examinations yield no pathological findings. The treatment of TMD is subdivided into the following steps that are always related to underlying diagnoses: informing patients, self-observation, relaxation therapy, behavioral therapy, physiotherapy, drug therapy, therapeutic local anesthesia, splint therapy, and, if necessary, prosthetic and/or orthodontic therapy to restore a stable occlusion. PMID:22073067

  10. Understanding the Code: keeping accurate records.

    PubMed

    Griffith, Richard

    2015-10-01

    In his continuing series looking at the legal and professional implications of the Nursing and Midwifery Council's revised Code of Conduct, Richard Griffith discusses the elements of accurate record keeping under Standard 10 of the Code. This article considers the importance of accurate record keeping for the safety of patients and protection of district nurses. The legal implications of records are explained along with how district nurses should write records to ensure these legal requirements are met. PMID:26418404

  11. Reusable, robust, and accurate laser-generated photonic nanosensor.

    PubMed

    Yetisen, Ali K; Montelongo, Yunuen; da Cruz Vasconcellos, Fernando; Martinez-Hurtado, J L; Neupane, Sankalpa; Butt, Haider; Qasim, Malik M; Blyth, Jeffrey; Burling, Keith; Carmody, J Bryan; Evans, Mark; Wilkinson, Timothy D; Kubota, Lauro T; Monteiro, Michael J; Lowe, Christopher R

    2014-06-11

    Developing noninvasive and accurate diagnostics that are easily manufactured, robust, and reusable will provide monitoring of high-risk individuals in any clinical or point-of-care environment. We have developed a clinically relevant optical glucose nanosensor that can be reused at least 400 times without a compromise in accuracy. The use of a single 6 ns laser (λ = 532 nm, 200 mJ) pulse rapidly produced off-axis Bragg diffraction gratings consisting of ordered silver nanoparticles embedded within a phenylboronic acid-functionalized hydrogel. This sensor exhibited reversible large wavelength shifts and diffracted the spectrum of narrow-band light over the wavelength range λpeak ≈ 510-1100 nm. The experimental sensitivity of the sensor permits diagnosis of glucosuria in the urine samples of diabetic patients with an improved performance compared to commercial high-throughput urinalysis devices. The sensor response was achieved within 5 min, reset to baseline in ∼10 s. It is anticipated that this sensing platform will have implications for the development of reusable, equipment-free colorimetric point-of-care diagnostic devices for diabetes screening. PMID:24844116

  12. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  13. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  14. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  15. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  16. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  17. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    NASA Astrophysics Data System (ADS)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-01

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ-ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  18. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    SciTech Connect

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-21

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  19. Cable Diagnostic Focused Initiative

    SciTech Connect

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  20. TARA diagnostic set

    SciTech Connect

    Sevillano, E.; Brau, K.; Goodrich, P.; Irby, J.; Mauel, M.; Post, R.S.; Smith, D.K.; Sullivan, J.

    1985-05-01

    The TARA Tandem Mirror Experiment has recently begun operation. The set of diagnostics available at this time is discussed. The following diagnostics are now in use: diamagnetic loops, a multichord microwave interferometer, Langmuir and emissive probes, pick-up loops, and secondary-emission detectors. End-loss diagnostics include net current detector arrays, Faraday cup arrays, swept particle analyzer arrays, and calorimetry. Light-emission measurements are made in the visible and VUV regions. A multichord fiber-optic array for plasma position detection is also used. In addition, a three-channel charge exchange analyzer, a hard x-ray system, and fast pressure gauges are available.

  1. Melioidosis Diagnostic Workshop, 20131

    PubMed Central

    AuCoin, David; Baccam, Prasith; Baggett, Henry C.; Baird, Rob; Bhengsri, Saithip; Blaney, David D.; Brett, Paul J.; Brooks, Timothy J.G.; Brown, Katherine A.; Chantratita, Narisara; Cheng, Allen C.; Dance, David A.B.; Decuypere, Saskia; Defenbaugh, Dawn; Gee, Jay E.; Houghton, Raymond; Jorakate, Possawat; Lertmemongkolchai, Ganjana; Limmathurotsakul, Direk; Merlin, Toby L.; Mukhopadhyay, Chiranjay; Norton, Robert; Peacock, Sharon J.; Rolim, Dionne B.; Simpson, Andrew J.; Steinmetz, Ivo; Stoddard, Robyn A.; Stokes, Martha M.; Sue, David; Tuanyok, Apichai; Whistler, Toni; Wuthiekanun, Vanaporn; Walke, Henry T.

    2015-01-01

    Melioidosis is a severe disease that can be difficult to diagnose because of its diverse clinical manifestations and a lack of adequate diagnostic capabilities for suspected cases. There is broad interest in improving detection and diagnosis of this disease not only in melioidosis-endemic regions but also outside these regions because melioidosis may be underreported and poses a potential bioterrorism challenge for public health authorities. Therefore, a workshop of academic, government, and private sector personnel from around the world was convened to discuss the current state of melioidosis diagnostics, diagnostic needs, and future directions. PMID:25626057

  2. Fiber diffraction of skin and nails provides an accurate diagnosis of malignancies

    SciTech Connect

    James, Veronica J.

    2009-10-21

    An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatory test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.

  3. ECE diagnostic of high temperature ECRH heated plasmas on FTU

    SciTech Connect

    Zerbini, M; Buratti, P; Tudisco, O; Giruzzi, G; Bruschi, A; Cirant, S; Granucci, G; Simonetto, A; Sozzi, C; Gandini, F; Pacella, D; Fournier, K B; Finkenthal, M

    2000-01-31

    The Electron Cyclotron Emission (ECE) diagnostic on FTU tokamak is routinely performed with a Michelson interferometer with spectral range extending up to 1300 GHz. The diagnostic allowed accurate electron temperature measurements during the recent 140 Ghz Electron Cyclotron Resonance Heating (ECRH) experiments on FTU. Very accurate measurements have been performed on a wide range of electron temperatures and profile peaking. The ECE measurements have been compared with Thomson Scattering and with observations of X-ray spectra from highly stripped molybdenum ions. The suprathermal emission in these conditions has been studied.

  4. Accurate projector calibration method by using an optical coaxial camera.

    PubMed

    Huang, Shujun; Xie, Lili; Wang, Zhangying; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian

    2015-02-01

    Digital light processing (DLP) projectors have been widely utilized to project digital structured-light patterns in 3D imaging systems. In order to obtain accurate 3D shape data, it is important to calibrate DLP projectors to obtain the internal parameters. The existing projector calibration methods have complicated procedures or low accuracy of the obtained parameters. This paper presents a novel method to accurately calibrate a DLP projector by using an optical coaxial camera. The optical coaxial geometry is realized by a plate beam splitter, so the DLP projector can be treated as a true inverse camera. A plate having discrete markers on the surface is used to calibrate the projector. The corresponding projector pixel coordinate of each marker on the plate is determined by projecting vertical and horizontal sinusoidal fringe patterns on the plate surface and calculating the absolute phase. The internal parameters of the DLP projector are obtained by the corresponding point pair between the projector pixel coordinate and the world coordinate of discrete markers. Experimental results show that the proposed method can accurately calibrate the internal parameters of a DLP projector. PMID:25967789

  5. Video integrated measurement system. [Diagnostic display devices

    SciTech Connect

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  6. [Gastroparesis. Definition, diagnostics, and therapy].

    PubMed

    von Arnim, U

    2015-06-01

    Gastroparesis is characterized by a constellation of upper gastrointestinal symptoms in association with delayed gastric emptying in the absence of mechanical outlet obstruction from the stomach. Major symptoms are nausea, vomiting, early satiety or postprandial fullness, bloating, and abdominal or epigastric pain. Idiopathic, diabetic, and postsurgical causes represent the most common etiologies. Diagnostic procedures for the evaluation of gastroparesis comprise gastric emptying scintigraphy (gold standard), (13)C-octanoate breath testing, and a wireless motility capsule. Management of gastroparesis includes normalization of nutritional state, relief of symptoms, glycemic control, and improvement of gastric emptying. Medical treatment entails use of prokinetic drugs, which are currently the first-line therapy. Nausea and vomiting might be positively influenced by antiemetic drugs. Gastric electronic stimulation and surgical interventions should be used in well-defined patients and represent a therapeutic option in tertiary centers. PMID:25940143

  7. Invasive diagnostic techniques in idiopathic interstitial pneumonias.

    PubMed

    Poletti, Venerino; Ravaglia, Claudia; Gurioli, Carlo; Piciucchi, Sara; Dubini, Alessandra; Cavazza, Alberto; Chilosi, Marco; Rossi, Andrea; Tomassetti, Sara

    2016-01-01

    Fibrosing interstitial lung diseases (f-ILDs) represent a heterogeneous group of disorders in which the aetiology may be identified or, not infrequently, remain unknown. Establishing a correct diagnosis of a distinct f-ILD requires a multidisciplinary approach, integrating clinical profile, physiological and laboratory data, radiological appearance and, when appropriate, histological findings. Surgical lung biopsy is still considered the most important diagnostic tool as it is able to provide lung samples large enough for identification of complex patterns such as usual interstitial pneumonitis (UIP) and nonspecific interstitial pneumonitis. However, this procedure is accompanied by significant morbidity and mortality. Bronchoalveolar lavage is still a popular diagnostic tool allowing identification of alternative diagnoses in patients with suspected idiopathic pulmonary fibrosis (IPF) when an increase in lymphocytes is detected. Conventional transbronchial lung biopsy has a very low sensitivity in detecting the UIP pattern and its role in this clinical-radiological context is marginal. The introduction of less invasive methods such as transbronchial cryobiopsy show great promise to clinical practice as they can be used to obtain samples large enough to morphologically support a diagnosis of IPF or other idiopathic interstitial pneumonias, along with fewer complications. Recent advances in the field suggest that less invasive methods of lung sampling, without significant side effects, in combination with other diagnostic methods could replace the need for surgical lung biopsy in the future. Indeed, these new multidisciplinary procedures may become the main diagnostic work-up method for patients with suspected idiopathic interstitial pneumonia. PMID:26682637

  8. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    SciTech Connect

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  9. Pediatric diagnostic imaging

    SciTech Connect

    Gyll, C.; Blake, N.S.

    1986-01-01

    This book treats the practical problems of pediatric radiography and radiological procedures. Written jointly by a radiographer and a radiologist, it covers pediatric positioning and procedures. An extended chapter covers neonatal radiography and radiology.

  10. Patient Radiation Doses in Interventional Cardiology Procedures

    PubMed Central

    Pantos, Ioannis; Patatoukas, Georgios; Katritsis, Demosthenes G; Efstathopoulos, Efstathios

    2009-01-01

    Interventional cardiology procedures result in substantial patient radiation doses due to prolonged fluoroscopy time and radiographic exposure. The procedures that are most frequently performed are coronary angiography, percutaneous coronary interventions, diagnostic electrophysiology studies and radiofrequency catheter ablation. Patient radiation dose in these procedures can be assessed either by measurements on a series of patients in real clinical practice or measurements using patient-equivalent phantoms. In this article we review the derived doses at non-pediatric patients from 72 relevant studies published during the last 22 years in international scientific literature. Published results indicate that patient radiation doses vary widely among the different interventional cardiology procedures but also among equivalent studies. Discrepancies of the derived results are patient-, procedure-, physician-, and fluoroscopic equipmentrelated. Nevertheless, interventional cardiology procedures can subject patients to considerable radiation doses. Efforts to minimize patient exposure should always be undertaken. PMID:20066141

  11. Radioactive diagnostic agent

    SciTech Connect

    Shigematsu, A.; Aihara, M.; Matsuda, M.; Suzuki, A.; Tsuya, A.

    1984-02-07

    A radioactive diagnostic agent for renal cortex, adrenal cortex, myocardium, brain stem, spinal nerve, etc., which comprises as an essential component monoiodoacetic acid wherein the iodine atom is radioactive.

  12. Multiple Procedure Payment Reduction: Health Policy Update.

    PubMed

    Rehani, B; Hirsch, J A; Dillon, W P; González, R G; Lev, M H; Schaefer, P W

    2015-11-01

    Multiple Procedure Payment Reduction currently applies to multiple diagnostic imaging services administered to the same patient during the same day and entails a 50% decrease in the technical component and a 25% decrease in the professional component reimbursement. This might change with time due to further legislation, so it is important to be up-to-date on these health policy developments. PMID:26381559

  13. 9 CFR 98.17 - Procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Disease Exists § 98.17 Procedures. (a) Housing of the donor dam. (1) Beginning at least 24 hours before a... region of origin; and (ii) A high prevalence or an increase in the incidence of a communicable disease in... pooled, frozen in liquid nitrogen, and sent to the Foreign Animal Disease Diagnostic Laboratory...

  14. Manual of diagnostic imaging

    SciTech Connect

    Gaylord, G.; Baker, S.; Davis, L.

    1988-01-01

    This book is on ordering and understanding the results of radiologic studies. Main sections are (I) Diagnostic Radiology serves as a basic introduction; (II) Diagnostic Modalities dedicates a chapter to each imaging modality in a clinical context, with a brief technical description and patient preparation guidelines; and (III) Organ System Imaging contains a chapter on each major organ system, covering the abilities and limitations of each modality to image a specific organ system and the significance of anatomic, physiologic, and general pathologic information.

  15. A highly accurate interatomic potential for argon

    NASA Astrophysics Data System (ADS)

    Aziz, Ronald A.

    1993-09-01

    A modified potential based on the individually damped model of Douketis, Scoles, Marchetti, Zen, and Thakkar [J. Chem. Phys. 76, 3057 (1982)] is presented which fits, within experimental error, the accurate ultraviolet (UV) vibration-rotation spectrum of argon determined by UV laser absorption spectroscopy by Herman, LaRocque, and Stoicheff [J. Chem. Phys. 89, 4535 (1988)]. Other literature potentials fail to do so. The potential also is shown to predict a large number of other properties and is probably the most accurate characterization of the argon interaction constructed to date.

  16. Accurate Molecular Dimensions from Stearic Acid Monolayers.

    ERIC Educational Resources Information Center

    Lane, Charles A.; And Others

    1984-01-01

    Discusses modifications in the fatty acid monolayer experiment to reduce the inaccurate moleculary data students usually obtain. Copies of the experimental procedure used and a Pascal computer program to work up the data are available from the authors. (JN)

  17. Writer`s guide for technical procedures

    SciTech Connect

    1998-12-01

    A primary objective of operations conducted in the US Department of Energy (DOE) complex is safety. Procedures are a critical element of maintaining a safety envelope to ensure safe facility operation. This DOE Writer`s Guide for Technical Procedures addresses the content, format, and style of technical procedures that prescribe production, operation of equipment and facilities, and maintenance activities. The DOE Writer`s Guide for Management Control Procedures and DOE Writer`s Guide for Emergency and Alarm Response Procedures are being developed to assist writers in developing nontechnical procedures. DOE is providing this guide to assist writers across the DOE complex in producing accurate, complete, and usable procedures that promote safe and efficient operations that comply with DOE orders, including DOE Order 5480.19, Conduct of Operations for DOE Facilities, and 5480.6, Safety of Department of Energy-Owned Nuclear Reactors.

  18. Hemoptysis with diagnostic dilemma.

    PubMed

    Pramanik, Bimalendu

    2013-02-01

    Hemoptysis is a common symptom. Although initial diagnostic workup, including a chest radiograph, often gives a clue to the cause, it provides no diagnostic hints in 3.0-42.2% of episodes of hemoptysis. To describe those cases with no diagnostic hints at initial investigations, experts have used different terms, including unexplained hemoptysis, idiopathic hemoptysis, cryptogenic hemoptysis and hemoptysis with normal chest radiographs. As hemoptysis is a common symptom of bronchogenic carcinoma, there is a concern of having underlying malignancy. Physicians value high-resolution computed tomography and fiberoptic bronchoscopy as the next investigations to establish diagnosis. These investigations however are expensive and nonspecific results are common in those cases of hemoptysis where initial diagnostic workup gives no clues to the cause. As a result, controversies exist with regard to their use. In this article, the author has proposed diagnostic approaches to evaluate those cases of hemoptysis with no diagnostic hints at initial investigation, after extensive review of published articles related to the case scenario. PMID:23362818

  19. [Diagnostics in osteology].

    PubMed

    Jakob, F; Genest, F; Seefried, L; Tsourdi, E; Lapa, C; Hofbauer, L C

    2016-07-01

    Clinical diagnostics in metabolic bone diseases cover a broad spectrum of conventional and state of the art methods ranging from the medical history and clinical examination to molecular imaging. Patient treatment is carried out in an interdisciplinary team due to the multiple interactions of bone with other organ systems. Diagnosis of osteoporosis is supported by high level national guidelines. A paradigm shift concerning the clinical relevance of bone mineral density measurement renders this now to be a strong risk factor rather than a diagnostic parameter, while strengthening the value of other clinical factors for risk assessment. The impact of parameters for muscle mass, structure and function is steadily increasing in all age groups. In order to identify underlying diseases that influence bone metabolism a panel of general laboratory diagnostic parameters is recommended. Markers for bone formation and resorption and specific parameters for the regulation of calcium and phosphate metabolism should be evaluated by specialists because they require diligence in preanalytics and experience in interpretation. Genetic diagnosis is well established for rare bone diseases while diagnostic panels are not yet available for routine diagnostics in polygenetic diseases such as osteoporosis. Conventional radiology is still very important to identify, e. g. fractures, osteolytic and osteoblastic lesions and extraosseous calcifications; however tomography-based methods which combine, e. g. scintigraphy or positron emission technologies with anatomical imaging are of increasing significance. Clinical diagnostics in osteology require profound knowledge and are subject to a dynamic evolution. PMID:27307159

  20. Face-off: A new identification procedure for child eyewitnesses.

    PubMed

    Price, Heather L; Fitzgerald, Ryan J

    2016-09-01

    In 2 experiments, we introduce a new "face-off" procedure for child eyewitness identifications. The new procedure, which is premised on reducing the stimulus set size, was compared with the showup and simultaneous procedures in Experiment 1 and with modified versions of the simultaneous and elimination procedures in Experiment 2. Several benefits of the face-off procedure were observed: it was significantly more diagnostic than the showup procedure; it led to significantly more correct rejections of target-absent lineups than the simultaneous procedures in both experiments, and it led to greater information gain than the modified elimination and simultaneous procedures. The face-off procedure led to consistently more conservative responding than the simultaneous procedures in both experiments. Given the commonly cited concern that children are too lenient in their decision criteria for identification tasks, the face-off procedure may offer a concrete technique to reduce children's high choosing rates. (PsycINFO Database Record PMID:27608069

  1. A robust and accurate formulation of molecular and colloidal electrostatics.

    PubMed

    Sun, Qiang; Klaseboer, Evert; Chan, Derek Y C

    2016-08-01

    This paper presents a re-formulation of the boundary integral method for the Debye-Hückel model of molecular and colloidal electrostatics that removes the mathematical singularities that have to date been accepted as an intrinsic part of the conventional boundary integral equation method. The essence of the present boundary regularized integral equation formulation consists of subtracting a known solution from the conventional boundary integral method in such a way as to cancel out the singularities associated with the Green's function. This approach better reflects the non-singular physical behavior of the systems on boundaries with the benefits of the following: (i) the surface integrals can be evaluated accurately using quadrature without any need to devise special numerical integration procedures, (ii) being able to use quadratic or spline function surface elements to represent the surface more accurately and the variation of the functions within each element is represented to a consistent level of precision by appropriate interpolation functions, (iii) being able to calculate electric fields, even at boundaries, accurately and directly from the potential without having to solve hypersingular integral equations and this imparts high precision in calculating the Maxwell stress tensor and consequently, intermolecular or colloidal forces, (iv) a reliable way to handle geometric configurations in which different parts of the boundary can be very close together without being affected by numerical instabilities, therefore potentials, fields, and forces between surfaces can be found accurately at surface separations down to near contact, and (v) having the simplicity of a formulation that does not require complex algorithms to handle singularities will result in significant savings in coding effort and in the reduction of opportunities for coding errors. These advantages are illustrated using examples drawn from molecular and colloidal electrostatics. PMID:27497538

  2. Accurate equilibrium structures of fluoro- and chloroderivatives of methane

    NASA Astrophysics Data System (ADS)

    Vogt, Natalja; Demaison, Jean; Rudolph, Heinz Dieter

    2014-11-01

    This work is a systematic study of molecular structure of fluoro-, chloro-, and fluorochloromethanes. For the first time, the accurate ab initio structure is computed for 10 molecules (CF4, CClF3, CCl2F2, CCl3F, CHClF2, CHCl2F, CH2F2, CH2ClF, CH2Cl2, and CCl4) at the coupled cluster level of electronic structure theory including single and double excitations augmented by a perturbational estimate of the effects of connected triple excitations [CCSD(T)] with all electrons being correlated and Gaussian basis sets of at least quadruple-ζ quality. Furthermore, when possible, namely for the molecules CH2F2, CH2Cl2, CH2ClF, CHClF2, and CCl2F2, accurate semi-experimental equilibrium (rSEe) structure has also been determined. This is achieved through a least-squares structural refinement procedure based on the equilibrium rotational constants of all available isotopomers, determined by correcting the experimental ground-state rotational constants with computed ab initio vibration-rotation interaction constants and electronic g-factors. The computed and semi-experimental equilibrium structures are in excellent agreement with each other, but the rSEe structure is generally more accurate, in particular for the CF and CCl bond lengths. The carbon-halogen bond length is discussed within the framework of the ligand close-packing model as a function of the atomic charges. For this purpose, the accurate equilibrium structures of some other molecules with alternative ligands, such as CH3Li, CF3CCH, and CF3CN, are also computed.

  3. A robust and accurate formulation of molecular and colloidal electrostatics

    NASA Astrophysics Data System (ADS)

    Sun, Qiang; Klaseboer, Evert; Chan, Derek Y. C.

    2016-08-01

    This paper presents a re-formulation of the boundary integral method for the Debye-Hückel model of molecular and colloidal electrostatics that removes the mathematical singularities that have to date been accepted as an intrinsic part of the conventional boundary integral equation method. The essence of the present boundary regularized integral equation formulation consists of subtracting a known solution from the conventional boundary integral method in such a way as to cancel out the singularities associated with the Green's function. This approach better reflects the non-singular physical behavior of the systems on boundaries with the benefits of the following: (i) the surface integrals can be evaluated accurately using quadrature without any need to devise special numerical integration procedures, (ii) being able to use quadratic or spline function surface elements to represent the surface more accurately and the variation of the functions within each element is represented to a consistent level of precision by appropriate interpolation functions, (iii) being able to calculate electric fields, even at boundaries, accurately and directly from the potential without having to solve hypersingular integral equations and this imparts high precision in calculating the Maxwell stress tensor and consequently, intermolecular or colloidal forces, (iv) a reliable way to handle geometric configurations in which different parts of the boundary can be very close together without being affected by numerical instabilities, therefore potentials, fields, and forces between surfaces can be found accurately at surface separations down to near contact, and (v) having the simplicity of a formulation that does not require complex algorithms to handle singularities will result in significant savings in coding effort and in the reduction of opportunities for coding errors. These advantages are illustrated using examples drawn from molecular and colloidal electrostatics.

  4. Early diagnostic of concurrent gear degradation processes progressing under time-varying loads

    NASA Astrophysics Data System (ADS)

    Guilbault, Raynald; Lalonde, Sébastien

    2016-08-01

    This study develops a gear diagnostic procedure for the detection of multi- and concurrent degradation processes evolving under time-varying loads. Instead of a conventional comparison between a descriptor and an alarm level, this procedure bases its detection strategy on a descriptor evolution tracking; a lasting descriptor increase denotes the presence of ongoing degradation mechanisms. The procedure works from time domain residual signals prepared in the frequency domain, and accepts any gear conditions as reference signature. To extract the load fluctuation repercussions, the procedure integrates a scaling factor. The investigation first examines a simplification assuming a linear connection between the load and the dynamic response amplitudes. However, while generally valuable, the precision losses associated with large load variations may mask the contribution of tiny flaws. To better reflect the real non-linear relation, the paper reformulates the scaling factor; a power law with an exponent value of 0.85 produces noticeable improvements of the load effect extraction. To reduce the consequences of remaining oscillations, the procedure also includes a filtering phase. During the validation program, a synthetic wear progression assuming a commensurate relation between the wear depth and friction assured controlled evolutions of the surface degradation influence, whereas the fillet crack growth remained entirely determined by the operation conditions. Globally, the tested conditions attest that the final strategy provides accurate monitoring of coexisting isolated damages and general surface deterioration, and that its tracking-detection capacities are unaffected by severe time variations of external loads. The procedure promptly detects the presence of evolving abnormal phenomena. The tests show that the descriptor curve shapes virtually describe the constant wear progression superimposed on the crack length evolution. At the tooth fracture, the mean values of

  5. Accurate pointing of tungsten welding electrodes

    NASA Technical Reports Server (NTRS)

    Ziegelmeier, P.

    1971-01-01

    Thoriated-tungsten is pointed accurately and quickly by using sodium nitrite. Point produced is smooth and no effort is necessary to hold the tungsten rod concentric. The chemically produced point can be used several times longer than ground points. This method reduces time and cost of preparing tungsten electrodes.

  6. Equilibrium gas flow computations. I - Accurate and efficient calculation of equilibrium gas properties

    NASA Technical Reports Server (NTRS)

    Liu, Yen; Vinokur, Marcel

    1989-01-01

    This paper treats the accurate and efficient calculation of thermodynamic properties of arbitrary gas mixtures for equilibrium flow computations. New improvements in the Stupochenko-Jaffe model for the calculation of thermodynamic properties of diatomic molecules are presented. A unified formulation of equilibrium calculations for gas mixtures in terms of irreversible entropy is given. Using a highly accurate thermo-chemical data base, a new, efficient and vectorizable search algorithm is used to construct piecewise interpolation procedures with generate accurate thermodynamic variable and their derivatives required by modern computational algorithms. Results are presented for equilibrium air, and compared with those given by the Srinivasan program.

  7. Advanced smile diagnostics using CAD/CAM mock-ups.

    PubMed

    Sancho-Puchades, Manuel; Fehmer, Vincent; Hämmerle, Christoph; Sailer, Irena

    2015-01-01

    Diagnostics are essential for predictable restorative dentistry. Both patient and clinician must agree on a treatment goal before the final restorations are delivered to avoid future disappointments. However, fully understanding the patient's desires is difficult. A useful tool to overcome this problem is the diagnostic wax-up and mock-up. A potential treatment outcome is modeled in wax prior to treatment and transferred into the patient's mouth using silicon indexes and autopolymerizing resin to obtain the patient's approval. Yet, this time-consuming procedure only produces a single version of the possible treatment outcome, which can be unsatisfactory for both the patient and the restorative team. Contemporary digital technologies may provide advantageous features to aid in this diagnostic treatment step. This article reviews opportunities digital technologies offer in the diagnostic phase, and presents clinical cases to illustrate the procedures. PMID:26171442

  8. Advances in three-dimensional diagnostic radiology

    PubMed Central

    TER HAAR ROMENY, BART M.; ZUIDERVELD, KAREL J.; VAN WAES, PAUL F. G. M.; VAN WALSUM, THEO; VAN DER WEIJDEN, REMKO; WEICKERT, JOACHIM; STOKKING, RIK; WINK, ONNO; KALITZIN, STILIYAN; MAINTZ, TWAN; ZONNEVELD, FRANS; VIERGEVER, MAX A.

    1998-01-01

    The maturity of current 3D rendering software in combination with recent developments in computer vision techniques enable an exciting range of applications for the visualisation, measurement and interactive manipulation of volumetric data, relevant both for diagnostic imaging and for anatomy. This paper reviews recent work in this area from the Image Sciences Institute at Utrecht University. The processes that yield a useful visual presentation are sequential. After acquisition and before any visualisation, an essential step is to prepare the data properly: this field is known as ‘image processing’ or ‘computer vision’ in analogy with the processing in human vision. Examples will be discussed of modern image enhancement and denoising techniques, and the complex process of automatically finding the objects or regions of interest, i.e. segmentation. One of the newer and promising methodologies for image analysis is based on a mathematical analysis of the human (cortical) visual processing: multiscale image analysis. After preprocessing the 3D rendering can be acquired by simulating the ‘ray casting’ in the computer. New possibilities are presented, such as the integrated visualisation in one image of (accurately registered) datasets of the same patient acquired in different modality scanners. Other examples include colour coding of functional data such as SPECT brain perfusion or functional magnetic resonance (MR) data and even metric data such as skull thickness on the rendered 3D anatomy from MR or computed tomography (CT). Optimal use and perception of 3D visualisation in radiology requires fast display and truly interactive manipulation facilities. Modern and increasingly cheaper workstations (<$10000) allow this to be a reality. It is now possible to manipulate 3D images of 2563 at 15 frames per second interactively, placing virtual reality within reach. The possibilities of modern workstations become increasingly more sophisticated and versatile

  9. Usefulness of intra-procedural cone-beam computed tomography in modified balloon-occluded retrograde transvenous obliteration of gastric varices

    PubMed Central

    Lee, Edward Wolfgang; So, Naomi; Chapman, Ryan; McWilliams, Justin P; Loh, Christopher T; Busuttil, Ronald W; Kee, Stephen T

    2016-01-01

    AIM: To evaluate whether intra-procedural cone-beam computed tomography (CBCT) performed during modified balloon-occluded retrograde transvenous obliteration (mBRTO) can accurately determine technical success of complete variceal obliteration. METHODS: From June 2012 to December 2014, 15 patients who received CBCT during mBRTO for treatment of portal hypertensive gastric variceal bleeding were retrospectively evaluated. Three-dimensional (3D) CBCT images were performed and evaluated prior to the end of the procedure, and these were further analyzed and compared to the pre-procedure contrast-enhanced computed tomography to determine the technical success of mBRTO including: Complete occlusion/obliteration of: (1) gastrorenal shunt (GRS); (2) gastric varices; and (3) afferent feeding veins. Post-mBRTO contrast-enhanced CT was used to confirm the accuracy and diagnostic value of CBCT within 2-3 d. RESULTS: Intra-procedural 3D-CBCT images were 100% accurate in determining the technical success of mBRTO in all 15 cases. CBCT demonstrated complete occlusion/obliteration of GRS, gastric varices, collaterals and afferent feeding veins during mBRTO, which was confirmed with post-mBRTO CT. Two patients showed incomplete obliteration of gastric varices and feeding veins on CBCT, which therefore required additional gelfoam injections to complete the procedure. No patient required additional procedures or other interventions during their follow-up period (684 ± 279 d). CONCLUSION: CBCT during mBRTO appears to accurately and immediately determine the technical success of mBRTO. This may improve the technical and clinical success/outcome of mBRTO and reduce additional procedure time in the future. PMID:27158425

  10. MJO Simulation Diagnostics

    SciTech Connect

    Waliser, D; Sperber, K; Hendon, H; Kim, D; Maloney, E; Wheeler, M; Weickmann, K; Zhang, C; Donner, L; Gottschalck, J; Higgins, W; Kang, I; Legler, D; Moncrieff, M; Schubert, S; Stern, W; Vitart, F; Wang, B; Wang, W; Woolnough, S

    2008-06-02

    The Madden-Julian Oscillation (MJO) interacts with, and influences, a wide range of weather and climate phenomena (e.g., monsoons, ENSO, tropical storms, mid-latitude weather), and represents an important, and as yet unexploited, source of predictability at the subseasonal time scale. Despite the important role of the MJO in our climate and weather systems, current global circulation models (GCMs) exhibit considerable shortcomings in representing this phenomenon. These shortcomings have been documented in a number of multi-model comparison studies over the last decade. However, diagnosis of model performance has been challenging, and model progress has been difficult to track, due to the lack of a coherent and standardized set of MJO diagnostics. One of the chief objectives of the US CLIVAR MJO Working Group is the development of observation-based diagnostics for objectively evaluating global model simulations of the MJO in a consistent framework. Motivation for this activity is reviewed, and the intent and justification for a set of diagnostics is provided, along with specification for their calculation, and illustrations of their application. The diagnostics range from relatively simple analyses of variance and correlation, to more sophisticated space-time spectral and empirical orthogonal function analyses. These diagnostic techniques are used to detect MJO signals, to construct composite life-cycles, to identify associations of MJO activity with the mean state, and to describe interannual variability of the MJO.

  11. Development of Companion Diagnostics

    PubMed Central

    Mankoff, David A.; Edmonds, Christine E.; Farwell, Michael D.; Pryma, Daniel A.

    2016-01-01

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient’s cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has “hit” the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2–targeted therapy. The review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic. PMID:26687857

  12. Revisiting Tversky's diagnosticity principle.

    PubMed

    Evers, Ellen R K; Lakens, Daniël

    2014-01-01

    Similarity is a fundamental concept in cognition. In 1977, Amos Tversky published a highly influential feature-based model of how people judge the similarity between objects. The model highlights the context-dependence of similarity judgments, and challenged geometric models of similarity. One of the context-dependent effects Tversky describes is the diagnosticity principle. The diagnosticity principle determines which features are used to cluster multiple objects into subgroups. Perceived similarity between items within clusters is expected to increase, while similarity between items in different clusters decreases. Here, we present two pre-registered replications of the studies on the diagnosticity effect reported in Tversky (1977). Additionally, one alternative mechanism that has been proposed to play a role in the original studies, an increase in the choice for distractor items (a substitution effect, see Medin et al., 1995), is examined. Our results replicate those found by Tversky (1977), revealing an average diagnosticity-effect of 4.75%. However, when we eliminate the possibility of substitution effects confounding the results, a meta-analysis of the data provides no indication of any remaining effect of diagnosticity. PMID:25161638

  13. Revisiting Tversky's diagnosticity principle

    PubMed Central

    Evers, Ellen R. K.; Lakens, Daniël

    2013-01-01

    Similarity is a fundamental concept in cognition. In 1977, Amos Tversky published a highly influential feature-based model of how people judge the similarity between objects. The model highlights the context-dependence of similarity judgments, and challenged geometric models of similarity. One of the context-dependent effects Tversky describes is the diagnosticity principle. The diagnosticity principle determines which features are used to cluster multiple objects into subgroups. Perceived similarity between items within clusters is expected to increase, while similarity between items in different clusters decreases. Here, we present two pre-registered replications of the studies on the diagnosticity effect reported in Tversky (1977). Additionally, one alternative mechanism that has been proposed to play a role in the original studies, an increase in the choice for distractor items (a substitution effect, see Medin et al., 1995), is examined. Our results replicate those found by Tversky (1977), revealing an average diagnosticity-effect of 4.75%. However, when we eliminate the possibility of substitution effects confounding the results, a meta-analysis of the data provides no indication of any remaining effect of diagnosticity. PMID:25161638

  14. Feedback about More Accurate versus Less Accurate Trials: Differential Effects on Self-Confidence and Activation

    ERIC Educational Resources Information Center

    Badami, Rokhsareh; VaezMousavi, Mohammad; Wulf, Gabriele; Namazizadeh, Mahdi

    2012-01-01

    One purpose of the present study was to examine whether self-confidence or anxiety would be differentially affected by feedback from more accurate rather than less accurate trials. The second purpose was to determine whether arousal variations (activation) would predict performance. On Day 1, participants performed a golf putting task under one of…

  15. Design and evaluation of a unique RT-qPCR assay for diagnostic quality control assessment that is applicable to pathogen detection in three species of salmonid fish

    PubMed Central

    2013-01-01

    Background The detection of pathogens at early stages of infection is a key point for disease control in aquaculture. Therefore, accurate diagnostic procedures are a must. Real-time PCR has been a mainstay in diagnostics over the years due to its speed, specificity, sensitivity, reproducibility and throughput; as such, real-time PCR is a target for improvement. Nevertheless, to validate a novel diagnostic tool, correct setup of the assay, including proper endogenous controls to evaluate the quantity and quality of the samples and to detect possible sample degradation, is compulsory. This work aims to design a unique RT-qPCR assay for pathogen detection in the three salmonid species reared in Chile. The assay uses elongation factor 1 alpha as the single endogenous control, thus avoiding the need for multiple endogenous controls, as well as multiple validations and non-comparable quality control parameters. Results The in vivo and in vitro analyses of samples from Salmo salar, Oncorhynchus mykiss and Oncorhynchus kisutch showed that when primers were accurately selected to target conserved regions of the elongation factor 1 alpha (ELF1α) gene, a single novel RT-qPCR assay yielding similar and reproducible Ct values between the three species could be designed. The opposite occurred when an assay originally designed for Salmo salar was tested in samples from the two species of the genus Oncorhynchus. Conclusions Here, we report the design and evaluation of an accurate trans-species RT-qPCR assay that uses the elongation factor 1 alpha (ELF1α) gene as an endogenous control and is applicable for diagnostic purposes in samples obtained from the three salmonid species reared in Chile. PMID:24040749

  16. Recent improvements of the JET lithium beam diagnostic

    SciTech Connect

    Brix, M.; Morgan, P.; Stamp, M.; Zastrow, K.-D.; Dunai, D.; Meszaros, B.; Petravich, G.; Refy, D. I.; Szabolics, T.; Zoletnik, S.; Lupelli, I.; Marsen, S.; Melson, T. F.; Silva, C. [EURATOM Collaboration: JET-EFDA Contributors

    2012-10-15

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  17. Adaptive Analytic Mapping Procedures for Simple and Accurate Calculation of Scattering Lengths and Photoassociation Absorption Intensities

    NASA Astrophysics Data System (ADS)

    Le Roy, Robert J.; Meshkov, Vladimir V.; Stolyarov, Andrej V.

    2009-06-01

    We have shown that one and two-parameter analytical mapping functions such as r(y;bar{r}, α)=bar{r}[1 + {1}/{α} tan(π y/2)] and r(y;bar{r})=bar{r} [ {1+ y}/{1-y} ] transform the conventional radial Schrödinger equation into equivalent alternate forms {d^2φ(y)}/{dy^2} = [{π^2}/{4}+({2μ}/ {hbar^2} ) g^2(y) [E - U(r(y))

  18. Algorithm for Video Summarization of Bronchoscopy Procedures

    PubMed Central

    2011-01-01

    Background The duration of bronchoscopy examinations varies considerably depending on the diagnostic and therapeutic procedures used. It can last more than 20 minutes if a complex diagnostic work-up is included. With wide access to videobronchoscopy, the whole procedure can be recorded as a video sequence. Common practice relies on an active attitude of the bronchoscopist who initiates the recording process and usually chooses to archive only selected views and sequences. However, it may be important to record the full bronchoscopy procedure as documentation when liability issues are at stake. Furthermore, an automatic recording of the whole procedure enables the bronchoscopist to focus solely on the performed procedures. Video recordings registered during bronchoscopies include a considerable number of frames of poor quality due to blurry or unfocused images. It seems that such frames are unavoidable due to the relatively tight endobronchial space, rapid movements of the respiratory tract due to breathing or coughing, and secretions which occur commonly in the bronchi, especially in patients suffering from pulmonary disorders. Methods The use of recorded bronchoscopy video sequences for diagnostic, reference and educational purposes could be considerably extended with efficient, flexible summarization algorithms. Thus, the authors developed a prototype system to create shortcuts (called summaries or abstracts) of bronchoscopy video recordings. Such a system, based on models described in previously published papers, employs image analysis methods to exclude frames or sequences of limited diagnostic or education value. Results The algorithm for the selection or exclusion of specific frames or shots from video sequences recorded during bronchoscopy procedures is based on several criteria, including automatic detection of "non-informative", frames showing the branching of the airways and frames including pathological lesions. Conclusions The paper focuses on the

  19. Feedback about more accurate versus less accurate trials: differential effects on self-confidence and activation.

    PubMed

    Badami, Rokhsareh; VaezMousavi, Mohammad; Wulf, Gabriele; Namazizadeh, Mahdi

    2012-06-01

    One purpose of the present study was to examine whether self-confidence or anxiety would be differentially affected byfeedback from more accurate rather than less accurate trials. The second purpose was to determine whether arousal variations (activation) would predict performance. On day 1, participants performed a golf putting task under one of two conditions: one group received feedback on the most accurate trials, whereas another group received feedback on the least accurate trials. On day 2, participants completed an anxiety questionnaire and performed a retention test. Shin conductance level, as a measure of arousal, was determined. The results indicated that feedback about more accurate trials resulted in more effective learning as well as increased self-confidence. Also, activation was a predictor of performance. PMID:22808705

  20. MR Neurography: Diagnostic Imaging in the PNS.

    PubMed

    Kollmer, J; Bendszus, M; Pham, M

    2015-10-01

    The diagnostic work-up of peripheral neuropathies is often challenging and is mainly based on a combination of clinical and electrophysiological examinations. One of the most important difficulties is the accurate determination of the lesion site (lesion localization), lesion extension, and spatial lesion dispersion, which all represent essential diagnostic information crucial for finding the correct diagnosis and hence an adequate therapeutic approach. A typical pitfall in the conventional diagnostic reasoning is the differentiation between a distal, complete cross-sectional nerve lesion and a more proximally located, fascicular nerve lesion. Magnetic resonance neurography (MRN) has been proven to be capable of improving the diagnostic accuracy by providing direct, noninvasive visualization of nerve injury with high structural resolution even reaching the anatomical level of single nerve fascicles (fascicular imaging) and at the same time with large anatomical coverage. It is also feasible to detect structural nerve damage earlier and with higher sensitivity than gold-standard nerve conduction studies. The purpose of this study is to review the literature for current developments and advances in MRN for the precise spatial detection of nerve lesions in focal and non-focal disorders of the peripheral nervous system. PMID:26070607

  1. Anatomical Brain Images Alone Can Accurately Diagnose Chronic Neuropsychiatric Illnesses

    PubMed Central

    Bansal, Ravi; Staib, Lawrence H.; Laine, Andrew F.; Hao, Xuejun; Xu, Dongrong; Liu, Jun; Weissman, Myrna; Peterson, Bradley S.

    2012-01-01

    Objective Diagnoses using imaging-based measures alone offer the hope of improving the accuracy of clinical diagnosis, thereby reducing the costs associated with incorrect treatments. Previous attempts to use brain imaging for diagnosis, however, have had only limited success in diagnosing patients who are independent of the samples used to derive the diagnostic algorithms. We aimed to develop a classification algorithm that can accurately diagnose chronic, well-characterized neuropsychiatric illness in single individuals, given the availability of sufficiently precise delineations of brain regions across several neural systems in anatomical MR images of the brain. Methods We have developed an automated method to diagnose individuals as having one of various neuropsychiatric illnesses using only anatomical MRI scans. The method employs a semi-supervised learning algorithm that discovers natural groupings of brains based on the spatial patterns of variation in the morphology of the cerebral cortex and other brain regions. We used split-half and leave-one-out cross-validation analyses in large MRI datasets to assess the reproducibility and diagnostic accuracy of those groupings. Results In MRI datasets from persons with Attention-Deficit/Hyperactivity Disorder, Schizophrenia, Tourette Syndrome, Bipolar Disorder, or persons at high or low familial risk for Major Depressive Disorder, our method discriminated with high specificity and nearly perfect sensitivity the brains of persons who had one specific neuropsychiatric disorder from the brains of healthy participants and the brains of persons who had a different neuropsychiatric disorder. Conclusions Although the classification algorithm presupposes the availability of precisely delineated brain regions, our findings suggest that patterns of morphological variation across brain surfaces, extracted from MRI scans alone, can successfully diagnose the presence of chronic neuropsychiatric disorders. Extensions of these

  2. New model accurately predicts reformate composition

    SciTech Connect

    Ancheyta-Juarez, J.; Aguilar-Rodriguez, E. )

    1994-01-31

    Although naphtha reforming is a well-known process, the evolution of catalyst formulation, as well as new trends in gasoline specifications, have led to rapid evolution of the process, including: reactor design, regeneration mode, and operating conditions. Mathematical modeling of the reforming process is an increasingly important tool. It is fundamental to the proper design of new reactors and revamp of existing ones. Modeling can be used to optimize operating conditions, analyze the effects of process variables, and enhance unit performance. Instituto Mexicano del Petroleo has developed a model of the catalytic reforming process that accurately predicts reformate composition at the higher-severity conditions at which new reformers are being designed. The new AA model is more accurate than previous proposals because it takes into account the effects of temperature and pressure on the rate constants of each chemical reaction.

  3. Accurate colorimetric feedback for RGB LED clusters

    NASA Astrophysics Data System (ADS)

    Man, Kwong; Ashdown, Ian

    2006-08-01

    We present an empirical model of LED emission spectra that is applicable to both InGaN and AlInGaP high-flux LEDs, and which accurately predicts their relative spectral power distributions over a wide range of LED junction temperatures. We further demonstrate with laboratory measurements that changes in LED spectral power distribution with temperature can be accurately predicted with first- or second-order equations. This provides the basis for a real-time colorimetric feedback system for RGB LED clusters that can maintain the chromaticity of white light at constant intensity to within +/-0.003 Δuv over a range of 45 degrees Celsius, and to within 0.01 Δuv when dimmed over an intensity range of 10:1.

  4. Accurate mask model for advanced nodes

    NASA Astrophysics Data System (ADS)

    Zine El Abidine, Nacer; Sundermann, Frank; Yesilada, Emek; Ndiaye, El Hadji Omar; Mishra, Kushlendra; Paninjath, Sankaranarayanan; Bork, Ingo; Buck, Peter; Toublan, Olivier; Schanen, Isabelle

    2014-07-01

    Standard OPC models consist of a physical optical model and an empirical resist model. The resist model compensates the optical model imprecision on top of modeling resist development. The optical model imprecision may result from mask topography effects and real mask information including mask ebeam writing and mask process contributions. For advanced technology nodes, significant progress has been made to model mask topography to improve optical model accuracy. However, mask information is difficult to decorrelate from standard OPC model. Our goal is to establish an accurate mask model through a dedicated calibration exercise. In this paper, we present a flow to calibrate an accurate mask enabling its implementation. The study covers the different effects that should be embedded in the mask model as well as the experiment required to model them.

  5. Accurate guitar tuning by cochlear implant musicians.

    PubMed

    Lu, Thomas; Huang, Juan; Zeng, Fan-Gang

    2014-01-01

    Modern cochlear implant (CI) users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼ 30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task. PMID:24651081

  6. Two highly accurate methods for pitch calibration

    NASA Astrophysics Data System (ADS)

    Kniel, K.; Härtig, F.; Osawa, S.; Sato, O.

    2009-11-01

    Among profiles, helix and tooth thickness pitch is one of the most important parameters of an involute gear measurement evaluation. In principle, coordinate measuring machines (CMM) and CNC-controlled gear measuring machines as a variant of a CMM are suited for these kinds of gear measurements. Now the Japan National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) and the German national metrology institute the Physikalisch-Technische Bundesanstalt (PTB) have each developed independently highly accurate pitch calibration methods applicable to CMM or gear measuring machines. Both calibration methods are based on the so-called closure technique which allows the separation of the systematic errors of the measurement device and the errors of the gear. For the verification of both calibration methods, NMIJ/AIST and PTB performed measurements on a specially designed pitch artifact. The comparison of the results shows that both methods can be used for highly accurate calibrations of pitch standards.

  7. Accurate modeling of parallel scientific computations

    NASA Technical Reports Server (NTRS)

    Nicol, David M.; Townsend, James C.

    1988-01-01

    Scientific codes are usually parallelized by partitioning a grid among processors. To achieve top performance it is necessary to partition the grid so as to balance workload and minimize communication/synchronization costs. This problem is particularly acute when the grid is irregular, changes over the course of the computation, and is not known until load time. Critical mapping and remapping decisions rest on the ability to accurately predict performance, given a description of a grid and its partition. This paper discusses one approach to this problem, and illustrates its use on a one-dimensional fluids code. The models constructed are shown to be accurate, and are used to find optimal remapping schedules.

  8. Accurate Guitar Tuning by Cochlear Implant Musicians

    PubMed Central

    Lu, Thomas; Huang, Juan; Zeng, Fan-Gang

    2014-01-01

    Modern cochlear implant (CI) users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task. PMID:24651081

  9. ORION laser target diagnostics

    SciTech Connect

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.; and others

    2012-10-15

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  10. ORION laser target diagnostics.

    PubMed

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics. PMID:23126904

  11. An accurate registration technique for distorted images

    NASA Technical Reports Server (NTRS)

    Delapena, Michele; Shaw, Richard A.; Linde, Peter; Dravins, Dainis

    1990-01-01

    Accurate registration of International Ultraviolet Explorer (IUE) images is crucial because the variability of the geometrical distortions that are introduced by the SEC-Vidicon cameras ensures that raw science images are never perfectly aligned with the Intensity Transfer Functions (ITFs) (i.e., graded floodlamp exposures that are used to linearize and normalize the camera response). A technique for precisely registering IUE images which uses a cross correlation of the fixed pattern that exists in all raw IUE images is described.

  12. Accurate maser positions for MALT-45

    NASA Astrophysics Data System (ADS)

    Jordan, Christopher; Bains, Indra; Voronkov, Maxim; Lo, Nadia; Jones, Paul; Muller, Erik; Cunningham, Maria; Burton, Michael; Brooks, Kate; Green, James; Fuller, Gary; Barnes, Peter; Ellingsen, Simon; Urquhart, James; Morgan, Larry; Rowell, Gavin; Walsh, Andrew; Loenen, Edo; Baan, Willem; Hill, Tracey; Purcell, Cormac; Breen, Shari; Peretto, Nicolas; Jackson, James; Lowe, Vicki; Longmore, Steven

    2013-10-01

    MALT-45 is an untargeted survey, mapping the Galactic plane in CS (1-0), Class I methanol masers, SiO masers and thermal emission, and high frequency continuum emission. After obtaining images from the survey, a number of masers were detected, but without accurate positions. This project seeks to resolve each maser and its environment, with the ultimate goal of placing the Class I methanol maser into a timeline of high mass star formation.

  13. LEDA and APT beam diagnostics instrumentation

    SciTech Connect

    Gilpatrick, J.D.; Johnson, K.F.; Hodapp, T.R.

    1997-10-01

    A 20-MeV 100-mA-cw proton-accelerator, Low Energy Demonstration Accelerator (LEDA), is presently being developed, fabricated, and tested at Los Alamos National Laboratory (LANL). The beam diagnostic instrumentation for LEDA and the final 1700-GeV Accelerator Production of Tritium (APT) are classified into two categories: operation and characterization instrumentation. The operational instrumentation does not intercept or minimally-intercepts the beam and are sufficiently prompt and robust to provide accurate information to the operators and commissioners during full-current cw beam operation. The characterization instrumentation, primarily utilized during commissioning project-phases, operates under more traditional 100-mA-peak and approximately 0.1-mA-average beam-current conditions. This paper will review some of the LEDA and APT operational beam diagnostic instrumentation.

  14. Diagnostics For Recirculating And Energy Recovered Linacs

    SciTech Connect

    Geoffrey A. Krafft; Jean-Claude Denard

    2002-12-18

    In this paper, the electron beam diagnostics developed for recirculating electron accelerators will be reviewed. The main novelties in dealing with such accelerators are: to have sufficient information and control possibilities for the longitudinal phase space, to have means to accurately set the recirculation path length, and to have a means to distinguish the beam passes on measurements of position in the linac proper. The solutions to these problems obtained at Jefferson Laboratory and elsewhere will be discussed. In addition, more standard instrumentation (profiling and emittance measurements) will be reviewed in the context of recirculating linacs. Finally, and looking forward, electron beam diagnostics for applications to high current energy recovered linacs will be discussed.

  15. Accurate phase-shift velocimetry in rock.

    PubMed

    Shukla, Matsyendra Nath; Vallatos, Antoine; Phoenix, Vernon R; Holmes, William M

    2016-06-01

    Spatially resolved Pulsed Field Gradient (PFG) velocimetry techniques can provide precious information concerning flow through opaque systems, including rocks. This velocimetry data is used to enhance flow models in a wide range of systems, from oil behaviour in reservoir rocks to contaminant transport in aquifers. Phase-shift velocimetry is the fastest way to produce velocity maps but critical issues have been reported when studying flow through rocks and porous media, leading to inaccurate results. Combining PFG measurements for flow through Bentheimer sandstone with simulations, we demonstrate that asymmetries in the molecular displacement distributions within each voxel are the main source of phase-shift velocimetry errors. We show that when flow-related average molecular displacements are negligible compared to self-diffusion ones, symmetric displacement distributions can be obtained while phase measurement noise is minimised. We elaborate a complete method for the production of accurate phase-shift velocimetry maps in rocks and low porosity media and demonstrate its validity for a range of flow rates. This development of accurate phase-shift velocimetry now enables more rapid and accurate velocity analysis, potentially helping to inform both industrial applications and theoretical models. PMID:27111139

  16. Accurate Molecular Polarizabilities Based on Continuum Electrostatics

    PubMed Central

    Truchon, Jean-François; Nicholls, Anthony; Iftimie, Radu I.; Roux, Benoît; Bayly, Christopher I.

    2013-01-01

    A novel approach for representing the intramolecular polarizability as a continuum dielectric is introduced to account for molecular electronic polarization. It is shown, using a finite-difference solution to the Poisson equation, that the Electronic Polarization from Internal Continuum (EPIC) model yields accurate gas-phase molecular polarizability tensors for a test set of 98 challenging molecules composed of heteroaromatics, alkanes and diatomics. The electronic polarization originates from a high intramolecular dielectric that produces polarizabilities consistent with B3LYP/aug-cc-pVTZ and experimental values when surrounded by vacuum dielectric. In contrast to other approaches to model electronic polarization, this simple model avoids the polarizability catastrophe and accurately calculates molecular anisotropy with the use of very few fitted parameters and without resorting to auxiliary sites or anisotropic atomic centers. On average, the unsigned error in the average polarizability and anisotropy compared to B3LYP are 2% and 5%, respectively. The correlation between the polarizability components from B3LYP and this approach lead to a R2 of 0.990 and a slope of 0.999. Even the F2 anisotropy, shown to be a difficult case for existing polarizability models, can be reproduced within 2% error. In addition to providing new parameters for a rapid method directly applicable to the calculation of polarizabilities, this work extends the widely used Poisson equation to areas where accurate molecular polarizabilities matter. PMID:23646034

  17. Accurate phase-shift velocimetry in rock

    NASA Astrophysics Data System (ADS)

    Shukla, Matsyendra Nath; Vallatos, Antoine; Phoenix, Vernon R.; Holmes, William M.

    2016-06-01

    Spatially resolved Pulsed Field Gradient (PFG) velocimetry techniques can provide precious information concerning flow through opaque systems, including rocks. This velocimetry data is used to enhance flow models in a wide range of systems, from oil behaviour in reservoir rocks to contaminant transport in aquifers. Phase-shift velocimetry is the fastest way to produce velocity maps but critical issues have been reported when studying flow through rocks and porous media, leading to inaccurate results. Combining PFG measurements for flow through Bentheimer sandstone with simulations, we demonstrate that asymmetries in the molecular displacement distributions within each voxel are the main source of phase-shift velocimetry errors. We show that when flow-related average molecular displacements are negligible compared to self-diffusion ones, symmetric displacement distributions can be obtained while phase measurement noise is minimised. We elaborate a complete method for the production of accurate phase-shift velocimetry maps in rocks and low porosity media and demonstrate its validity for a range of flow rates. This development of accurate phase-shift velocimetry now enables more rapid and accurate velocity analysis, potentially helping to inform both industrial applications and theoretical models.

  18. Enhancing ADHD and LD Diagnostic Accuracy Using Career Instruments

    ERIC Educational Resources Information Center

    Dipeolu, Abiola; Hargrave, Stephanie; Storlie, Cassandra A.

    2015-01-01

    Individuals diagnosed with mental health disorders may have work-related difficulties that impact functioning in all life domains. With limited research on the integration of career and mental health counseling, authors used a discriminant function analysis to assess the predictability of accurately identifying diagnostic categories among 258…

  19. Training in Structured Diagnostic Assessment Using DSM-IV Criteria

    ERIC Educational Resources Information Center

    Ponniah, Kathryn; Weissman, Myrna M.; Bledsoe, Sarah E.; Verdeli, Helen; Gameroff, Marc J.; Mufson, Laura; Fitterling, Heidi; Wickramaratne, Priya

    2011-01-01

    Objectives: Determining a patient's psychiatric diagnosis is an important first step for the selection of empirically supported treatments and a critical component of evidence-based practice. Structured diagnostic assessment covers the range of psychiatric diagnoses and is usually more complete and accurate than unstructured assessment. Method: We…

  20. Viral diagnostics: will new technology save the day

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Technology for infectious agent detection continues to evolve, particularly molecular methods which first emerged in the mid-1970’s. The goals of new technology in diagnostics are to achieve the highest sensitivity and specificity possible to accurately identify the infection status of an individua...

  1. Accurate Anisotropic Fast Marching for Diffusion-Based Geodesic Tractography

    PubMed Central

    Jbabdi, S.; Bellec, P.; Toro, R.; Daunizeau, J.; Pélégrini-Issac, M.; Benali, H.

    2008-01-01

    Using geodesics for inferring white matter fibre tracts from diffusion-weighted MR data is an attractive method for at least two reasons: (i) the method optimises a global criterion, and hence is less sensitive to local perturbations such as noise or partial volume effects, and (ii) the method is fast, allowing to infer on a large number of connexions in a reasonable computational time. Here, we propose an improved fast marching algorithm to infer on geodesic paths. Specifically, this procedure is designed to achieve accurate front propagation in an anisotropic elliptic medium, such as DTI data. We evaluate the numerical performance of this approach on simulated datasets, as well as its robustness to local perturbation induced by fiber crossing. On real data, we demonstrate the feasibility of extracting geodesics to connect an extended set of brain regions. PMID:18299703

  2. A BPM calibration procedure using TBT data

    SciTech Connect

    Yang, M.J.; Crisp, J.; Prieto, P.; /Fermilab

    2007-06-01

    Accurate BPM calibration is crucial for lattice analysis. It is also reassuring when the calibration can be independently verified. This paper outlines a procedure that can extract BPM calibration information from TBT orbit data. The procedure is developed as an extension to the Turn-By-Turn lattice analysis [1]. Its application to data from both Recycler Ring and Main Injector (MI) at Fermilab have produced very encouraging results. Some specifics in hardware design will be mentioned to contrast that of analysis results.

  3. Diagnostic Value of Transthoracic Echocardiography in Patients With Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery.

    PubMed

    Li, Rong-Juan; Sun, Zhonghua; Yang, Jiao; Yang, Ya; Li, Yi-Jia; Leng, Zhao-Ting; Liu, Guo-Wen; Pu, Li-Hong

    2016-04-01

    Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality associated with early infant mortality and sudden death in adults. Transthoracic echocardiography (TTE) plays an important role in early detection and diagnosis of ALCAPA as a noninvasive modality. However, its diagnostic value is not well studied. The purpose of this study is to determine the performance of TTE in the diagnostic assessment of ALCAPA as compared with coronary CT and invasive coronary angiography.A total of 22 patients (13 women and 9 men, mean age, 12.9 ± 19.5 years) with ALCAPA who underwent echocardiographic examination for clinical diagnosis were retrospectively reviewed and analyzed. Transthoracic echocardiographic features of ALCAPA were analyzed and its diagnostic value was compared with invasive coronary angiography and coronary CT angiography (CTA) with surgical findings serving as the gold standard. Surgery was performed in all of the patients to establish the dual coronary artery system. Five underwent the Takeuchi procedure and 17 had re-implantation of the anomalous left coronary artery. Of 20 patients, echocardiographic diagnoses were in good agreement with findings at surgery, resulting in the diagnostic accuracy of 90.9%. Two cases were misdiagnosed-one as the right coronary artery to pulmonary artery fistula and the other as rheumatic heart disease. The echocardiographic features of these patients with ALCAPA included: abnormal left coronary ostium arising from the pulmonary trunk with retrograde coronary artery flow in 20 patients; enlargement of the right coronary artery in 17 patients; abundant intercoronary septal collaterals in 17 patients; and moderate and significant mitral regurgitation in 14 patients. The diagnostic accuracy of invasive coronary angiography (in 17 patients) and coronary CTA (in 9 patients) was 100%.This study shows that TTE is an accurate, noninvasive imaging modality for displaying

  4. Diagnostic Value of Transthoracic Echocardiography in Patients With Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery

    PubMed Central

    Li, Rong-Juan; Sun, Zhonghua; Yang, Jiao; Yang, Ya; Li, Yi-Jia; Leng, Zhao-Ting; Liu, Guo-Wen; Pu, Li-Hong

    2016-01-01

    Abstract Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality associated with early infant mortality and sudden death in adults. Transthoracic echocardiography (TTE) plays an important role in early detection and diagnosis of ALCAPA as a noninvasive modality. However, its diagnostic value is not well studied. The purpose of this study is to determine the performance of TTE in the diagnostic assessment of ALCAPA as compared with coronary CT and invasive coronary angiography. A total of 22 patients (13 women and 9 men, mean age, 12.9 ± 19.5 years) with ALCAPA who underwent echocardiographic examination for clinical diagnosis were retrospectively reviewed and analyzed. Transthoracic echocardiographic features of ALCAPA were analyzed and its diagnostic value was compared with invasive coronary angiography and coronary CT angiography (CTA) with surgical findings serving as the gold standard. Surgery was performed in all of the patients to establish the dual coronary artery system. Five underwent the Takeuchi procedure and 17 had re-implantation of the anomalous left coronary artery. Of 20 patients, echocardiographic diagnoses were in good agreement with findings at surgery, resulting in the diagnostic accuracy of 90.9%. Two cases were misdiagnosed—one as the right coronary artery to pulmonary artery fistula and the other as rheumatic heart disease. The echocardiographic features of these patients with ALCAPA included: abnormal left coronary ostium arising from the pulmonary trunk with retrograde coronary artery flow in 20 patients; enlargement of the right coronary artery in 17 patients; abundant intercoronary septal collaterals in 17 patients; and moderate and significant mitral regurgitation in 14 patients. The diagnostic accuracy of invasive coronary angiography (in 17 patients) and coronary CTA (in 9 patients) was 100%. This study shows that TTE is an accurate, noninvasive imaging modality

  5. Diagnostic discography: what is the clinical utility?

    PubMed

    Provenzano, David A

    2012-02-01

    The diagnosis and treatment of discogenic back pain is challenging. Provocation discography, an invasive spinal procedure, has been suggested as a diagnostic test for internal disc disruption to provide information on disc morphology and reproduction of symptoms. Current applications consist of the evaluation of persistent spinal pain in individuals, including postoperative patients, as well as providing a guide for patient selection for spinal fusion surgery and minimally invasive interventional pain procedures. While the validity of discography has been questioned by multiple scientific studies, technical refinements have addressed many of the initial limitations. An updated review on the safety and utility of discography will be provided, covering key areas of debate including false-positive rates, technical parameters, clinical utility, and risk of discography procedural-related intervertebral disc damage. PMID:22147277

  6. Accurate skin dose measurements using radiochromic film in clinical applications

    SciTech Connect

    Devic, S.; Seuntjens, J.; Abdel-Rahman, W.; Evans, M.; Olivares, M.; Podgorsak, E.B.; Vuong, Te; Soares, Christopher G.

    2006-04-15

    Megavoltage x-ray beams exhibit the well-known phenomena of dose buildup within the first few millimeters of the incident phantom surface, or the skin. Results of the surface dose measurements, however, depend vastly on the measurement technique employed. Our goal in this study was to determine a correction procedure in order to obtain an accurate skin dose estimate at the clinically relevant depth based on radiochromic film measurements. To illustrate this correction, we have used as a reference point a depth of 70 {mu}. We used the new GAFCHROMIC[reg] dosimetry films (HS, XR-T, and EBT) that have effective points of measurement at depths slightly larger than 70 {mu}. In addition to films, we also used an Attix parallel-plate chamber and a home-built extrapolation chamber to cover tissue-equivalent depths in the range from 4 {mu} to 1 mm of water-equivalent depth. Our measurements suggest that within the first millimeter of the skin region, the PDD for a 6 MV photon beam and field size of 10x10 cm{sup 2} increases from 14% to 43%. For the three GAFCHROMIC[reg] dosimetry film models, the 6 MV beam entrance skin dose measurement corrections due to their effective point of measurement are as follows: 15% for the EBT, 15% for the HS, and 16% for the XR-T model GAFCHROMIC[reg] films. The correction factors for the exit skin dose due to the build-down region are negligible. There is a small field size dependence for the entrance skin dose correction factor when using the EBT GAFCHROMIC[reg] film model. Finally, a procedure that uses EBT model GAFCHROMIC[reg] film for an accurate measurement of the skin dose in a parallel-opposed pair 6 MV photon beam arrangement is described.

  7. Glycan-based diagnostic devices: current progress, challenges and perspectives.

    PubMed

    Wang, Sheng-Kai; Cheng, Chao-Min

    2015-12-01

    Diagnosis is an essential launching point for accurate medical treatment, and rapid and accurate diagnostic approaches have become the increasingly vital goal inspiring developments in a variety of analytical methods. With increasing attention in the area of glycosciences, the roles that carbohydrates play in many diseases have been elucidated, and the use of carbohydrates as disease biomarkers has become an emerging diagnostics strategy. This review article does not intend to comprehensively include all carbohydrate-related diagnostics studies. We do, however, wish to describe carbohydrate recognition and the design of sensitive detecting devices, especially those developed recently, so that readers might better grasp the principles behind such devices and relevant detection strategies, particularly those favoring inexpensive, rapid, and point-of-care (POC) approaches. PMID:26421872

  8. An Approach for Balancing Diagnostic Image Quality with Cancer Risk: Application to Pediatric Diagnostic Imaging of 99mTc-Dimercaptosuccinic Acid

    PubMed Central

    Sgouros, George; Frey, Eric C.; Bolch, Wesley E.; Wayson, Michael B.; Abadia, Andres F.; Treves, S. Ted

    2012-01-01

    A recent survey of pediatric hospitals showed a large variability in the activity administered for diagnostic nuclear medicine imaging of children. Imaging guidelines, especially for pediatric patients, must balance the risks associated with radiation exposure with the need to obtain the high-quality images necessary to derive the benefits of an accurate clinical diagnosis. Methods Pharmacokinetic modeling and a pediatric series of nonuniform rational B-spline–based phantoms have been used to simulate 99mTc-dimercaptosuccinic acid SPECT images. Images were generated for several different administered activities and for several lesions with different target-to-background activity concentration ratios; the phantoms were also used to calculate organ S values for 99mTc. Channelized Hotelling observer methodology was used in a receiver-operating-characteristic analysis of the diagnostic quality of images with different modeled administered activities (i.e., count densities) for anthropomorphic reference phantoms representing two 10-y-old girls with equal weights but different body morphometry. S value–based dosimetry was used to calculate the mean organ-absorbed doses to the 2 pediatric patients. Using BEIR VII age- and sex-specific risk factors, we converted absorbed doses to excess risk of cancer incidence and used them to directly assess the risk of the procedure. Results Combined, these data provided information about the tradeoff between cancer risk and diagnostic image quality for 2 phantoms having the same weight but different body morphometry. The tradeoff was different for the 2 phantoms, illustrating that weight alone may not be sufficient for optimally scaling administered activity in pediatric patients. Conclusion The study illustrates implementation of a rigorous approach for balancing the benefits of adequate image quality against the radiation risks and also demonstrates that weight-based adjustment to the administered activity is suboptimal

  9. [Basic principles of selection and use of diagnostic tests: analysis of the results of diagnostic studies].

    PubMed

    Carneiro, A V

    2001-11-01

    In clinical practice, in order to design and implement a specific therapeutic plan, as well as communicating an appropriate prognosis, the doctor needs to establish a precise diagnosis of the condition. Sometimes all one needs is a clinical impression. More often, however, the definition of an accurate diagnosis will need the interpretation of specific diagnostic tests as well. The rational use of diagnostic tests in cardiology--whether laboratorial or imagiologic--should be based on three factors: 1) validity of the study results about the test; 2) diagnostic properties of the test and 3) applicability of the test in the clinical setting. The rational use and correct interpretation of diagnostic tests are based on these three factors. In this article we present the basic principles concerning the validity of the results from the study that defined the specific test, and what level of evidence that constitutes. Other articles will address diagnostic properties of tests (sensitivity, specificity, positive and negative predictive values, likelihood ratios) as well as the applicability of the test in clinical practice. PMID:11826705

  10. Basic principles on selection and use of diagnostic tests: properties of diagnostic tests.

    PubMed

    Carneiro, A V

    2001-12-01

    In clinical practice, in order to design and implement a specific therapeutic plan, as well as communicating an appropriate prognosis, the doctor needs to establish a precise diagnosis of the condition. Sometimes all one needs is a clinical impression. More often, however, the definition of an accurate diagnosis will mandate the interpretation of specific diagnostic tests as well. The rational use of diagnostic tests in cardiology--whether laboratorial or imaging--should be based on three factors: 1) validity of results of studies on the test; 2) diagnostic properties of the test; and 3) applicability of the test in the clinical setting. The rational use and the correct interpretation of diagnostic tests are based on these three factors. In a previous article we presented the basic principles concerning the validity of the results from the study that defined the specific test, and what level of evidence that constitutes. In this article we present the diagnostic properties of tests (sensitivity, specificity, positive and negative predictive values, likelihood ratios, odds). Finally, in a forthcoming paper we will discuss the applicability of the test in clinical cardiological practice. PMID:11865687

  11. Coding and reimbursement of primary care debridement and excision procedures.

    PubMed

    Zuber, T J; Purvis, J R

    1992-12-01

    Current medical practice requires physicians to accurately report services provided to patients. Patient billing for debridement and excision procedures involves the selection of specific 1992 Physicians' Current Procedural Terminology codes. Although a site-specific surgical procedure code often yields higher reimbursement than a general procedure code, physicians should select the code that most accurately reflects the procedure performed. This review identifies the codes used to report destruction and excision procedures performed by primary care physicians. Included in this review are skin debridement, burn debridement, excision of benign and malignant lesions of the skin and subcutaneous tissue, cyst and ganglion excision, nail excision, anorectal lesion excision, shave, paring, and skin tag excision procedures, and foreign body removal. The Health Care Financing Administration's relative value units and one state's published Medicaid payment rates are included for each procedure code. Instructions are provided for selecting between multiple coding options when more than one code describes the service provided. PMID:1453151

  12. A time-accurate implicit method for chemical non-equilibrium flows at all speeds

    NASA Technical Reports Server (NTRS)

    Shuen, Jian-Shun

    1992-01-01

    A new time accurate coupled solution procedure for solving the chemical non-equilibrium Navier-Stokes equations over a wide range of Mach numbers is described. The scheme is shown to be very efficient and robust for flows with velocities ranging from M less than or equal to 10(exp -10) to supersonic speeds.

  13. 31 CFR 205.22 - How are accurate clearance patterns maintained?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false How are accurate clearance patterns maintained? 205.22 Section 205.22 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE, DEPARTMENT OF THE TREASURY FINANCIAL MANAGEMENT SERVICE RULES AND PROCEDURES FOR EFFICIENT FEDERAL-STATE...

  14. Studies and analyses of the Space Shuttle Main Engine: SSME failure data review, diagnostic survey and SSME diagnostic evaluation

    NASA Technical Reports Server (NTRS)

    Glover, R. C.; Kelley, B. A.; Tischer, A. E.

    1986-01-01

    The results of a review of the Space Shuttle Main Engine (SSME) failure data for the period 1980 through 1983 are presented. The data was collected, evaluated, and ranked according to procedures established during this study. A number of conclusions and recommendations are made based upon this failure data review. The results of a state-of-the-art diagnostic survey are also presented. This survey covered a broad range of diagnostic sensors and techniques and the findings were evaluated for application to the SSME. Finally, a discussion of the initial activities for the on-going SSME diagnostic evaluation is included.

  15. Heterodyne laser diagnostic system

    DOEpatents

    Globig, Michael A.; Johnson, Michael A.; Wyeth, Richard W.

    1990-01-01

    The heterodyne laser diagnostic system includes, in one embodiment, an average power pulsed laser optical spectrum analyzer for determining the average power of the pulsed laser. In another embodiment, the system includes a pulsed laser instantaneous optical frequency measurement for determining the instantaneous optical frequency of the pulsed laser.

  16. Flowfield modeling and diagnostics

    SciTech Connect

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques.

  17. Beam Diagnostics for FACET

    SciTech Connect

    Li, S.Z.; Hogan, M.J.; /SLAC

    2011-08-19

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

  18. Diagnostics for induction accelerators

    SciTech Connect

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960`s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore`s Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail.

  19. Tele diagnostic by web

    NASA Astrophysics Data System (ADS)

    Sugiyama, Shigeki

    2006-03-01

    Because of the development of multimedia technologies like Web and Internet, it now becomes possible to think about Tele Medicine and Tele Diagnostic for a distant place where no doctors and no nurses are situated at or are available. And also some kind of intelligence can be added onto them, which makes possible to give certain kind of medical treatment assistance or suggestions for a patient from a computer diagnostic base through the Internetworking. For doing this, here considers about a basic system of "Tele Diagnostic for a remote place" where it dose not have a doctor and a medical assistance. In order to implement the system, JAVA, VRML, HTML, and CORTONA are used as a basic language and a viewer. And also in order to add a kind of intelligence, Augmented Knowledge In Agent (AKIA) by using Back Propagation Neural Networks (BPNN) is used. And by this study, here can introduce the system that has the following basic mechanisms; By inputting physical data like temperature or blood pressure, the system would show a diagnostic assistance by TEXT. And also the bad place of body would be shown graphically if there were any. The system can be put onto Web, so that anybody could have this assistance at any place ubiquitously only if a person has Internetworking access.

  20. Molecular Beacons in Diagnostics

    PubMed Central

    Kramer, Fred Russell

    2012-01-01

    Recent technical advances have begun to realize the potential of molecular beacons to test for diverse infections in clinical diagnostic laboratories. These include the ability to test for, and quantify, multiple pathogens in the same clinical sample, and to detect antibiotic resistant strains within hours. The design principles of molecular beacons have also spawned a variety of allied technologies. PMID:22619695

  1. Equivalent Diagnostic Classification Models

    ERIC Educational Resources Information Center

    Maris, Gunter; Bechger, Timo

    2009-01-01

    Rupp and Templin (2008) do a good job at describing the ever expanding landscape of Diagnostic Classification Models (DCM). In many ways, their review article clearly points to some of the questions that need to be answered before DCMs can become part of the psychometric practitioners toolkit. Apart from the issues mentioned in this article that…

  2. Diagnosing Diagnostic Language Assessment

    ERIC Educational Resources Information Center

    Lee, Yong-Won

    2015-01-01

    Diagnostic language assessment (DLA) is gaining a lot of attention from language teachers, testers, and applied linguists. With a recent surge of interest in DLA, there seems to be an urgent need to assess where the field of DLA stands at the moment and develop a general sense of where it should be moving in the future. The current article, as the…

  3. Sexual Addiction: Diagnostic Problems

    ERIC Educational Resources Information Center

    Giugliano, John R.

    2009-01-01

    In recent years clinicians report a great deal of concern about definition, diagnostic assessment, and treatment modalities when dealing with what might be called out-of-control sexual behavior. Many terms have been used to describe the phenomenon of problematic sexual behavior. Many of these concepts overlap, some are no longer popular, and some…

  4. Rocket Engine Oscillation Diagnostics

    NASA Technical Reports Server (NTRS)

    Nesman, Tom; Turner, James E. (Technical Monitor)

    2002-01-01

    Rocket engine oscillating data can reveal many physical phenomena ranging from unsteady flow and acoustics to rotordynamics and structural dynamics. Because of this, engine diagnostics based on oscillation data should employ both signal analysis and physical modeling. This paper describes an approach to rocket engine oscillation diagnostics, types of problems encountered, and example problems solved. Determination of design guidelines and environments (or loads) from oscillating phenomena is required during initial stages of rocket engine design, while the additional tasks of health monitoring, incipient failure detection, and anomaly diagnostics occur during engine development and operation. Oscillations in rocket engines are typically related to flow driven acoustics, flow excited structures, or rotational forces. Additional sources of oscillatory energy are combustion and cavitation. Included in the example problems is a sampling of signal analysis tools employed in diagnostics. The rocket engine hardware includes combustion devices, valves, turbopumps, and ducts. Simple models of an oscillating fluid system or structure can be constructed to estimate pertinent dynamic parameters governing the unsteady behavior of engine systems or components. In the example problems it is shown that simple physical modeling when combined with signal analysis can be successfully employed to diagnose complex rocket engine oscillatory phenomena.

  5. Diagnostic Lessons as Assessment.

    ERIC Educational Resources Information Center

    Walker, Barbara J.

    Embedded in a sensitive instructional context rather than a stifling testing atmosphere, diagnostic lessons provide assessment that is reliable, practical, valid, and efficient. In this type of assessment, there are several determiners of instructional placement: (1) students' propensity to adapt strategies as a result of specified instruction,…

  6. Reducing Diagnostic Bias.

    ERIC Educational Resources Information Center

    McLaughlin, Jerry E.

    2002-01-01

    Skill using the American Psychiatric Association's 2000 "Diagnostic and Statistical Manual of Mental Disorders, Text Revision" is essential for increased professional credibility, career marketability, and third-party reimbursement of professional counselors. This article focuses on how to improve counselors' skill with the manual, by providing…

  7. Diagnostic du vertige

    PubMed Central

    Monday, Louise A.

    1981-01-01

    In cases of vertigo, the history is the most important diagnostic element. Questioning must be directed towards obtaining the most pertinent and precise answers possible. A classification based on the duration of vertigo, together with the physiopathology, is suggested. PMID:21289799

  8. Beamlet focal plane diagnostic

    SciTech Connect

    Caird, J.A.; Nielsen, N.D.; Patton, H.G.; Seppala, L.G.; Thompson, C.E.; Wegner, P.J.

    1996-12-01

    This paper describes the major optical and mechanical design features of the Beamlet Focal Plane Diagnostic system as well as measurements of the system performance, and typical data obtained to date. We also discuss the NIF requirements on the focal spot that we are interested in measuring, and some of our plans for future work using this system.

  9. Diagnostics and data fusion of robotic sensors

    SciTech Connect

    Dhar, M.; Bardsley, S; Cowper, L.; Hamm, R.; Jammu, V.; Wagner, J.

    1996-12-31

    Robotic systems for remediation of hazardous waste sites must be highly reliable to avoid equipment failures and subsequent possible exposure of personnel to hazardous environments. Safe, efficient cleanup operations also require accurate, complete knowledge of the task space. This paper presents progress made on a 18 month program to meet these needs. To enhance robot reliability, a conceptual design of a monitoring and diagnostic system is being developed to predict the onset of mechanical failure modes, provide maximum lead time to make operational changes or repairs, and minimize the occurrence of on-site breakdowns. To ensure safe operation, a comprehensive software package is being developed that will fuse data from multiple surface mapping sensors and poses so as to reduce the error effects in individual data points and provide accurate 3-D maps of a work space.

  10. Objective pain diagnostics: clinical neurophysiology.

    PubMed

    Garcia-Larrea, L

    2012-06-01

    Neurophysiological techniques help in diagnosis, prognosis and treatment of chronic pain, and are particularly useful to determine its neuropathic origin. According to current standards, the diagnosis of definite neuropathic pain (NP) needs objective confirmation of a lesion or disease of somatosensory systems, which can be provided by neurophysiological testing. Lesions causing NP mostly concern the pain-temperature pathways, and therefore neurophysiological procedures allowing the specific testing of these pathways (i.e., A-delta and C-fibres, spino-thalamo-cortical tracts) are essential for objective diagnosis. Different techniques to stimulate selectively pain-temperature pathways are discussed. Of these, laser-evoked potentials (LEPs) appear as the easiest and most reliable neurophysiological method of assessing nociceptive function, and their coupling with autonomic responses (e.g., galvanic skin response) and psychophysics (quantitative sensory testing - QST) can still enhance their diagnostic yield. Neurophysiological techniques not exploring specifically nociception, such as standard nerve conduction velocities (NCV) and SEPs to non-noxious stimulation, should be associated to the exploration of nociceptive systems, not only because both may be simultaneously affected to different degrees, but also because some specific painful symptoms, such as paroxysmal discharges, may depend on specific alteration of highly myelinated A-beta fibres. The choice of techniques is determined after anamnesis and clinical exam, and tries to answer a number of questions: (a) is the pain-related to injury of somatosensory pathways?; (b) to what extent are different subsystems affected?; (c) are mechanisms and lesion site in accordance with imaging data?; (d) are results of use for diagnostic or therapeutic follow-up? Neuropathic pain (NP) affects more than 15 million people in Western countries, and its belated diagnosis leads to insufficient or delayed therapy. The use of

  11. Accurately Mapping M31's Microlensing Population

    NASA Astrophysics Data System (ADS)

    Crotts, Arlin

    2004-07-01

    We propose to augment an existing microlensing survey of M31 with source identifications provided by a modest amount of ACS {and WFPC2 parallel} observations to yield an accurate measurement of the masses responsible for microlensing in M31, and presumably much of its dark matter. The main benefit of these data is the determination of the physical {or "einstein"} timescale of each microlensing event, rather than an effective {"FWHM"} timescale, allowing masses to be determined more than twice as accurately as without HST data. The einstein timescale is the ratio of the lensing cross-sectional radius and relative velocities. Velocities are known from kinematics, and the cross-section is directly proportional to the {unknown} lensing mass. We cannot easily measure these quantities without knowing the amplification, hence the baseline magnitude, which requires the resolution of HST to find the source star. This makes a crucial difference because M31 lens m ass determinations can be more accurate than those towards the Magellanic Clouds through our Galaxy's halo {for the same number of microlensing events} due to the better constrained geometry in the M31 microlensing situation. Furthermore, our larger survey, just completed, should yield at least 100 M31 microlensing events, more than any Magellanic survey. A small amount of ACS+WFPC2 imaging will deliver the potential of this large database {about 350 nights}. For the whole survey {and a delta-function mass distribution} the mass error should approach only about 15%, or about 6% error in slope for a power-law distribution. These results will better allow us to pinpoint the lens halo fraction, and the shape of the halo lens spatial distribution, and allow generalization/comparison of the nature of halo dark matter in spiral galaxies. In addition, we will be able to establish the baseline magnitude for about 50, 000 variable stars, as well as measure an unprecedentedly deta iled color-magnitude diagram and luminosity

  12. Accurate measurement of unsteady state fluid temperature

    NASA Astrophysics Data System (ADS)

    Jaremkiewicz, Magdalena

    2016-07-01

    In this paper, two accurate methods for determining the transient fluid temperature were presented. Measurements were conducted for boiling water since its temperature is known. At the beginning the thermometers are at the ambient temperature and next they are immediately immersed into saturated water. The measurements were carried out with two thermometers of different construction but with the same housing outer diameter equal to 15 mm. One of them is a K-type industrial thermometer widely available commercially. The temperature indicated by the thermometer was corrected considering the thermometers as the first or second order inertia devices. The new design of a thermometer was proposed and also used to measure the temperature of boiling water. Its characteristic feature is a cylinder-shaped housing with the sheath thermocouple located in its center. The temperature of the fluid was determined based on measurements taken in the axis of the solid cylindrical element (housing) using the inverse space marching method. Measurements of the transient temperature of the air flowing through the wind tunnel using the same thermometers were also carried out. The proposed measurement technique provides more accurate results compared with measurements using industrial thermometers in conjunction with simple temperature correction using the inertial thermometer model of the first or second order. By comparing the results, it was demonstrated that the new thermometer allows obtaining the fluid temperature much faster and with higher accuracy in comparison to the industrial thermometer. Accurate measurements of the fast changing fluid temperature are possible due to the low inertia thermometer and fast space marching method applied for solving the inverse heat conduction problem.

  13. Accurate upwind methods for the Euler equations

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1993-01-01

    A new class of piecewise linear methods for the numerical solution of the one-dimensional Euler equations of gas dynamics is presented. These methods are uniformly second-order accurate, and can be considered as extensions of Godunov's scheme. With an appropriate definition of monotonicity preservation for the case of linear convection, it can be shown that they preserve monotonicity. Similar to Van Leer's MUSCL scheme, they consist of two key steps: a reconstruction step followed by an upwind step. For the reconstruction step, a monotonicity constraint that preserves uniform second-order accuracy is introduced. Computational efficiency is enhanced by devising a criterion that detects the 'smooth' part of the data where the constraint is redundant. The concept and coding of the constraint are simplified by the use of the median function. A slope steepening technique, which has no effect at smooth regions and can resolve a contact discontinuity in four cells, is described. As for the upwind step, existing and new methods are applied in a manner slightly different from those in the literature. These methods are derived by approximating the Euler equations via linearization and diagonalization. At a 'smooth' interface, Harten, Lax, and Van Leer's one intermediate state model is employed. A modification for this model that can resolve contact discontinuities is presented. Near a discontinuity, either this modified model or a more accurate one, namely, Roe's flux-difference splitting. is used. The current presentation of Roe's method, via the conceptually simple flux-vector splitting, not only establishes a connection between the two splittings, but also leads to an admissibility correction with no conditional statement, and an efficient approximation to Osher's approximate Riemann solver. These reconstruction and upwind steps result in schemes that are uniformly second-order accurate and economical at smooth regions, and yield high resolution at discontinuities.

  14. The first accurate description of an aurora

    NASA Astrophysics Data System (ADS)

    Schröder, Wilfried

    2006-12-01

    As technology has advanced, the scientific study of auroral phenomena has increased by leaps and bounds. A look back at the earliest descriptions of aurorae offers an interesting look into how medieval scholars viewed the subjects that we study.Although there are earlier fragmentary references in the literature, the first accurate description of the aurora borealis appears to be that published by the German Catholic scholar Konrad von Megenberg (1309-1374) in his book Das Buch der Natur (The Book of Nature). The book was written between 1349 and 1350.

  15. Accurate density functional thermochemistry for larger molecules.

    SciTech Connect

    Raghavachari, K.; Stefanov, B. B.; Curtiss, L. A.; Lucent Tech.

    1997-06-20

    Density functional methods are combined with isodesmic bond separation reaction energies to yield accurate thermochemistry for larger molecules. Seven different density functionals are assessed for the evaluation of heats of formation, Delta H 0 (298 K), for a test set of 40 molecules composed of H, C, O and N. The use of bond separation energies results in a dramatic improvement in the accuracy of all the density functionals. The B3-LYP functional has the smallest mean absolute deviation from experiment (1.5 kcal mol/f).

  16. New law requires 'medically accurate' lesson plans.

    PubMed

    1999-09-17

    The California Legislature has passed a bill requiring all textbooks and materials used to teach about AIDS be medically accurate and objective. Statements made within the curriculum must be supported by research conducted in compliance with scientific methods, and published in peer-reviewed journals. Some of the current lesson plans were found to contain scientifically unsupported and biased information. In addition, the bill requires material to be "free of racial, ethnic, or gender biases." The legislation is supported by a wide range of interests, but opposed by the California Right to Life Education Fund, because they believe it discredits abstinence-only material. PMID:11366835

  17. Current developments in salivary diagnostics

    PubMed Central

    Foley, Joseph D; Bailey, Alison L; Campell, Charles L; Humphries, Roger L; Christodoulides, Nicolaos; Floriano, Pierre N; Simmons, Glennon; Bhagwandin, Bryon; Jacobson, James W; Redding, Spencer W; Ebersole, Jeffrey L; McDevitt, John T

    2010-01-01

    Salivary diagnostics is an emerging field that has progressed through several important developments in the past decade, including the publication of the human salivary proteome and the infusion of federal funds to integrate nanotechnologies and microfluidic engineering concepts into developing compact point-of-care devices for rapid analysis of this secretion. In this article, we discuss some of these developments and their relevance to the prognosis, diagnosis and management of periodontitis, as an oral target, and cardiovascular disease, as a systemic example for the potential of these biodiagnostics. Our findings suggest that several biomarkers are associated with distinct biological stages of these diseases and demonstrate promise as practical biomarkers in identifying and managing periodontal disease, and acute myocardial infarction. The majority of these studies have progressed through biomarker discovery, with the identified molecules requiring more robust clinical studies to enable substantive validation for disease diagnosis. It is predicted that with continued advances in this field the use of a combination of biomarkers in multiplex panels is likely to yield accurate screening tools for these diagnoses in the near future. PMID:20387312

  18. Current developments in salivary diagnostics.

    PubMed

    Miller, Craig S; Foley, Joseph D; Bailey, Alison L; Campell, Charles L; Humphries, Roger L; Christodoulides, Nicolaos; Floriano, Pierre N; Simmons, Glennon; Bhagwandin, Bryon; Jacobson, James W; Redding, Spencer W; Ebersole, Jeffrey L; McDevitt, John T

    2010-02-01

    Salivary diagnostics is an emerging field that has progressed through several important developments in the past decade, including the publication of the human salivary proteome and the infusion of federal funds to integrate nanotechnologies and microfluidic engineering concepts into developing compact point-of-care devices for rapid analysis of this secretion. In this article, we discuss some of these developments and their relevance to the prognosis, diagnosis and management of periodontitis, as an oral target, and cardiovascular disease, as a systemic example for the potential of these biodiagnostics. Our findings suggest that several biomarkers are associated with distinct biological stages of these diseases and demonstrate promise as practical biomarkers in identifying and managing periodontal disease, and acute myocardial infarction. The majority of these studies have progressed through biomarker discovery, with the identified molecules requiring more robust clinical studies to enable substantive validation for disease diagnosis. It is predicted that with continued advances in this field the use of a combination of biomarkers in multiplex panels is likely to yield accurate screening tools for these diagnoses in the near future. PMID:20387312

  19. Accurate Detection of Rifampicin-Resistant Mycobacterium Tuberculosis Strains.

    PubMed

    Song, Keum-Soo; Nimse, Satish Balasaheb; Kim, Hee Jin; Yang, Jeongseong; Kim, Taisun

    2016-01-01

    In 2013 alone, the death rate among the 9.0 million people infected with Mycobacterium tuberculosis (TB) worldwide was around 14%, which is unacceptably high. An empiric treatment of patients infected with TB or drug-resistant Mycobacterium tuberculosis (MDR-TB) strain can also result in the spread of MDR-TB. The diagnostic tools which are rapid, reliable, and have simple experimental protocols can significantly help in decreasing the prevalence rate of MDR-TB strain. We report the evaluation of the 9G technology based 9G DNAChips that allow accurate detection and discrimination of TB and MDR-TB-RIF. One hundred and thirteen known cultured samples were used to evaluate the ability of 9G DNAChip in the detection and discrimination of TB and MDR-TB-RIF strains. Hybridization of immobilized probes with the PCR products of TB and MDR-TB-RIF strains allow their detection and discrimination. The accuracy of 9G DNAChip was determined by comparing its results with sequencing analysis and drug susceptibility testing. Sequencing analysis showed 100% agreement with the results of 9G DNAChip. The 9G DNAChip showed very high sensitivity (95.4%) and specificity (100%). PMID:26999135

  20. Accurate Detection of Rifampicin-Resistant Mycobacterium Tuberculosis Strains

    PubMed Central

    Song, Keum-Soo; Nimse, Satish Balasaheb; Kim, Hee Jin; Yang, Jeongseong; Kim, Taisun

    2016-01-01

    In 2013 alone, the death rate among the 9.0 million people infected with Mycobacterium tuberculosis (TB) worldwide was around 14%, which is unacceptably high. An empiric treatment of patients infected with TB or drug-resistant Mycobacterium tuberculosis (MDR-TB) strain can also result in the spread of MDR-TB. The diagnostic tools which are rapid, reliable, and have simple experimental protocols can significantly help in decreasing the prevalence rate of MDR-TB strain. We report the evaluation of the 9G technology based 9G DNAChips that allow accurate detection and discrimination of TB and MDR-TB-RIF. One hundred and thirteen known cultured samples were used to evaluate the ability of 9G DNAChip in the detection and discrimination of TB and MDR-TB-RIF strains. Hybridization of immobilized probes with the PCR products of TB and MDR-TB-RIF strains allow their detection and discrimination. The accuracy of 9G DNAChip was determined by comparing its results with sequencing analysis and drug susceptibility testing. Sequencing analysis showed 100% agreement with the results of 9G DNAChip. The 9G DNAChip showed very high sensitivity (95.4%) and specificity (100%). PMID:26999135

  1. Informatics-based, highly accurate, noninvasive prenatal paternity testing

    PubMed Central

    Ryan, Allison; Baner, Johan; Demko, Zachary; Hill, Matthew; Sigurjonsson, Styrmir; Baird, Michael L.; Rabinowitz, Matthew

    2013-01-01

    Purpose: The aim of the study was to evaluate the diagnostic accuracy of an informatics-based, noninvasive, prenatal paternity test using array-based single-nucleotide polymorphism measurements of cell-free DNA isolated from maternal plasma. Methods: Blood samples were taken from 21 adult pregnant women (with gestational ages between 6 and 21 weeks), and a genetic sample was taken from the corresponding biological fathers. Paternity was confirmed by genetic testing of the infant, products of conception, control of fertilization, and/or preimplantation genetic diagnosis during in vitro fertilization. Parental DNA samples and maternal plasma cell-free DNA were amplified and analyzed using a HumanCytoSNP-12 array. An informatics-based method measured single-nucleotide polymorphism data, confirming or rejecting paternity. Each plasma sample with a sufficient fetal cell-free DNA fraction was independently tested against the confirmed father and 1,820 random, unrelated males. Results: One of the 21 samples had insufficient fetal cell-free DNA. The test correctly confirmed paternity for the remaining 20 samples (100%) when tested against the biological father, with P values of <10−4. For the 36,400 tests using an unrelated male as the alleged father, 99.95% (36,382) correctly excluded paternity and 0.05% (18) were indeterminate. There were no miscalls. Conclusion: A noninvasive paternity test using informatics-based analysis of single-nucleotide polymorphism array measurements accurately determined paternity early in pregnancy. PMID:23258349

  2. Multifocal Nodular Fatty Infiltration of the Liver: A Case Report of a Challenging Diagnostic Problem

    PubMed Central

    Tebala, Giovanni Domenico; Jwad, Anees; Khan, Abdul Quyyum; Long, Ervine; Sissons, Guy

    2016-01-01

    Patient: Female, 59 Final Diagnosis: Multifocal nodular fatty infiltration of the liver Symptoms: None Medication: — Clinical Procedure: Laparoscopy Specialty: Surgery Objective: Rare disease Background: Fatty infiltration of the liver usually has a diffuse pattern, but in very rare cases it presents as multiple focal lesions of the liver, mimicking metastases. A correct diagnosis is crucial to address prognosis and eventual treatment. Case Report: We present the case of a completely fit and asymptomatic patient referred for multiple bilateral liver metastases of unknown origin. She had no previous history of malignancy. She was extensively investigated with all locally available methods, including ultrasound scan, computed tomography, magnetic resonance imaging, upper and lower gastrointestinal endoscopy, and diagnostic laparoscopy. Imaging-guided biopsy and laparoscopic biopsy confirmed the diagnosis of multifocal fatty infiltration of the liver. Conclusions: The diagnosis of this condition can be challenging and an accurate initial clinical history must be part of a thorough clinical examination. Multimodal imaging is mandatory, but diagnostic laparoscopy with direct macrobiopsy may be necessary to clear all doubts. PMID:27017525

  3. Testing for cattle allergy: modified diagnostic cutoff levels improve sensitivity in symptomatic claw trimmers

    PubMed Central

    Dik, Natalja; Hallier, Ernst; Zuberbier, Torsten; Bergmann, Karl-Christian

    2010-01-01

    Background The diagnosis of cattle-related sensitization is complicated by the variability and complexity of cattle allergen extracts. Objective To evaluate a modified diagnostic procedure leading to more accurate results especially in the early phase of sensitization. Methods We tested 27 claw trimmers with and 65 without cattle-related symptoms using two commercially available cattle allergen extracts. We also used a self-prepared cattle allergen mix designed to represent the full spectrum of cattle allergens from a typical agricultural workplace. Results More than 50% of symptomatic claw trimmers showed negative test results with commercial extracts and a sensitization cutoff point of 0.35 kU/l. In contrast, with the self-prepared cattle allergen mix, positive results were observed for almost all of them. Evaluating the results of the commercial test kits at different cutoff levels, we found an ideal cutoff point to improve the sensitivity at 0.2 kU/l. Conclusion Additional tests with self-made cattle hair extracts can help to bridge the diagnostic gap seen in patients showing cattle-related symptoms, but negative results in commercially available tests. For early-stage sensitization screening, we propose to lower the cutoff level indicating sensitization to 0.2 kU/l. PMID:20658147

  4. General considerations and updates in pediatric gastrointestinal diagnostic endoscopy

    PubMed Central

    2010-01-01

    Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review. PMID:21189965

  5. Authentication Procedures - The Procedures and Integration Working Group

    SciTech Connect

    Kouzes, Richard T.; Bratcher, Leigh; Gosnell, Tom; Langner, Diana; MacArthur, D.; Mihalczo, John T.; Pura, Carolyn; Riedy, Alex; Rexroth, Paul; Scott, Mary; Springarn, Jay

    2001-05-31

    Authentication is how we establish trust in monitoring systems and measurements to verify compliance with, for example, the storage of nuclear weapons material. Authentication helps assure the monitoring party that accurate and reliable information is provided by any measurement system and that any irregularities are detected. The U.S. is developing its point of view on the procedures for authentication of monitoring systems now planned or contemplated for arms reduction and control applications. The authentication of a system utilizes a set of approaches, including: functional testing using trusted calibration sources, evaluation of documentation, evaluation of software, evaluation of hardware, random selection of hardware and software, tamper-indicating devices, and operational procedures. Authentication of measurement systems should occur throughout their lifecycles, starting with the elements of design, and moving to off-site authentication, on-siste authentication, and continuing with authentication following repair. The most important of these is the initial design of systems. Hardware and software design criteria and procurement decisions can make future authentication relatively straightforward or conversely very difficult. Facility decisions can likewise ease the procedures for authentication since reliable and effective monitoring systems and tampering indicating devices can help provide the assurance needed in the integrity of such items as measurement systems, spare equipment, and reference sources. This paper will summarize the results of the U.S. Authentication Task Force discussion on the role of procedures in authentication.

  6. Optical diagnostics in the oral cavity: an overview

    PubMed Central

    Wilder-Smith, P; Holtzman, J; Epstein, J; Le, A

    2014-01-01

    As the emphasis shifts from damage mitigation to disease prevention or reversal of early disease in the oral cavity, the need for sensitive and accurate detection and diagnostic tools become more important. Many novel and emergent optical diagnostic modalities for the oral cavity are becoming available to clinicians with a variety of desirable attributes including: (i) non-invasiveness, (ii) absence of ionizing radiation, (iii) patient-friendliness, (iv) real-time information (v) repeatability, and (vi) high-resolution surface and subsurface images. In this article, the principles behind optical diagnostic approaches, their feasibility and applicability for imaging soft and hard tissues, and their potential usefulness as a tool in the diagnosis of oral mucosal lesions, dental pathologies, and other dental applications will be reviewed. The clinical applications of light-based imaging technologies in the oral cavity and of their derivative devices will be discussed to provide the reader with a comprehensive understanding of emergent diagnostic modalities. PMID:20561224

  7. Merits and Pitfalls of Currently Used Diagnostic Tools in Mycetoma

    PubMed Central

    van de Sande, Wendy W. J.; Fahal, Ahmed H.; Goodfellow, Michael; Mahgoub, El Sheikh; Welsh, Oliverio; Zijlstra, Ed E.

    2014-01-01

    Treatment of mycetoma depends on the causative organism and since many organisms, both actinomycetes (actinomycetoma) and fungi (eumycetoma), are capable of producing mycetoma, an accurate diagnosis is crucial. Currently, multiple diagnostic tools are used to determine the extent of infections and to identify the causative agents of mycetoma. These include various imaging, cytological, histopathological, serological, and culture techniques; phenotypic characterisation; and molecular diagnostics. In this review, we summarize these techniques and identify their merits and pitfalls in the identification of the causative agents of mycetoma and the extent of the disease. We also emphasize the fact that there is no ideal diagnostic tool available to identify the causative agents and that future research should focus on the development of new and reliable diagnostic tools. PMID:24992636

  8. Particles and microfluidics merged: perspectives of highly sensitive diagnostic detection

    PubMed Central

    Bale, Shyam Sundhar; Bhushan, Abhinav; Shen, Keyue; Seker, Erkin; Polyak, Boris

    2014-01-01

    There is a growing need for diagnostic technologies that provide laboratories with solutions that improve quality, enhance laboratory system productivity, and provide accurate detection of a broad range of infectious diseases and cancers. Recent advances in micro- and nanoscience and engineering, in particular in the areas of particles and microfluidic technologies, have advanced the “lab-on-a-chip” concept towards the development of a new generation of point-of-care diagnostic devices that could significantly enhance test sensitivity and speed. In this review, we will discuss many of the recent advances in microfluidics and particle technologies with an eye towards merging these two technologies for application in medical diagnostics. Although the potential diagnostic applications are virtually unlimited, the most important applications are foreseen in the areas of biomarker research, cancer diagnosis, and detection of infectious microorganisms. PMID:25378716

  9. Accurate basis set truncation for wavefunction embedding

    NASA Astrophysics Data System (ADS)

    Barnes, Taylor A.; Goodpaster, Jason D.; Manby, Frederick R.; Miller, Thomas F.

    2013-07-01

    Density functional theory (DFT) provides a formally exact framework for performing embedded subsystem electronic structure calculations, including DFT-in-DFT and wavefunction theory-in-DFT descriptions. In the interest of efficiency, it is desirable to truncate the atomic orbital basis set in which the subsystem calculation is performed, thus avoiding high-order scaling with respect to the size of the MO virtual space. In this study, we extend a recently introduced projection-based embedding method [F. R. Manby, M. Stella, J. D. Goodpaster, and T. F. Miller III, J. Chem. Theory Comput. 8, 2564 (2012)], 10.1021/ct300544e to allow for the systematic and accurate truncation of the embedded subsystem basis set. The approach is applied to both covalently and non-covalently bound test cases, including water clusters and polypeptide chains, and it is demonstrated that errors associated with basis set truncation are controllable to well within chemical accuracy. Furthermore, we show that this approach allows for switching between accurate projection-based embedding and DFT embedding with approximate kinetic energy (KE) functionals; in this sense, the approach provides a means of systematically improving upon the use of approximate KE functionals in DFT embedding.

  10. Accurate radiative transfer calculations for layered media.

    PubMed

    Selden, Adrian C

    2016-07-01

    Simple yet accurate results for radiative transfer in layered media with discontinuous refractive index are obtained by the method of K-integrals. These are certain weighted integrals applied to the angular intensity distribution at the refracting boundaries. The radiative intensity is expressed as the sum of the asymptotic angular intensity distribution valid in the depth of the scattering medium and a transient term valid near the boundary. Integrated boundary equations are obtained, yielding simple linear equations for the intensity coefficients, enabling the angular emission intensity and the diffuse reflectance (albedo) and transmittance of the scattering layer to be calculated without solving the radiative transfer equation directly. Examples are given of half-space, slab, interface, and double-layer calculations, and extensions to multilayer systems are indicated. The K-integral method is orders of magnitude more accurate than diffusion theory and can be applied to layered scattering media with a wide range of scattering albedos, with potential applications to biomedical and ocean optics. PMID:27409700

  11. Fast and accurate propagation of coherent light

    PubMed Central

    Lewis, R. D.; Beylkin, G.; Monzón, L.

    2013-01-01

    We describe a fast algorithm to propagate, for any user-specified accuracy, a time-harmonic electromagnetic field between two parallel planes separated by a linear, isotropic and homogeneous medium. The analytical formulation of this problem (ca 1897) requires the evaluation of the so-called Rayleigh–Sommerfeld integral. If the distance between the planes is small, this integral can be accurately evaluated in the Fourier domain; if the distance is very large, it can be accurately approximated by asymptotic methods. In the large intermediate region of practical interest, where the oscillatory Rayleigh–Sommerfeld kernel must be applied directly, current numerical methods can be highly inaccurate without indicating this fact to the user. In our approach, for any user-specified accuracy ϵ>0, we approximate the kernel by a short sum of Gaussians with complex-valued exponents, and then efficiently apply the result to the input data using the unequally spaced fast Fourier transform. The resulting algorithm has computational complexity , where we evaluate the solution on an N×N grid of output points given an M×M grid of input samples. Our algorithm maintains its accuracy throughout the computational domain. PMID:24204184

  12. How Accurately can we Calculate Thermal Systems?

    SciTech Connect

    Cullen, D; Blomquist, R N; Dean, C; Heinrichs, D; Kalugin, M A; Lee, M; Lee, Y; MacFarlan, R; Nagaya, Y; Trkov, A

    2004-04-20

    I would like to determine how accurately a variety of neutron transport code packages (code and cross section libraries) can calculate simple integral parameters, such as K{sub eff}, for systems that are sensitive to thermal neutron scattering. Since we will only consider theoretical systems, we cannot really determine absolute accuracy compared to any real system. Therefore rather than accuracy, it would be more precise to say that I would like to determine the spread in answers that we obtain from a variety of code packages. This spread should serve as an excellent indicator of how accurately we can really model and calculate such systems today. Hopefully, eventually this will lead to improvements in both our codes and the thermal scattering models that they use in the future. In order to accomplish this I propose a number of extremely simple systems that involve thermal neutron scattering that can be easily modeled and calculated by a variety of neutron transport codes. These are theoretical systems designed to emphasize the effects of thermal scattering, since that is what we are interested in studying. I have attempted to keep these systems very simple, and yet at the same time they include most, if not all, of the important thermal scattering effects encountered in a large, water-moderated, uranium fueled thermal system, i.e., our typical thermal reactors.

  13. Accurate shear measurement with faint sources

    SciTech Connect

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao E-mail: walt@shao.ac.cn

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys.

  14. Accurate pose estimation for forensic identification

    NASA Astrophysics Data System (ADS)

    Merckx, Gert; Hermans, Jeroen; Vandermeulen, Dirk

    2010-04-01

    In forensic authentication, one aims to identify the perpetrator among a series of suspects or distractors. A fundamental problem in any recognition system that aims for identification of subjects in a natural scene is the lack of constrains on viewing and imaging conditions. In forensic applications, identification proves even more challenging, since most surveillance footage is of abysmal quality. In this context, robust methods for pose estimation are paramount. In this paper we will therefore present a new pose estimation strategy for very low quality footage. Our approach uses 3D-2D registration of a textured 3D face model with the surveillance image to obtain accurate far field pose alignment. Starting from an inaccurate initial estimate, the technique uses novel similarity measures based on the monogenic signal to guide a pose optimization process. We will illustrate the descriptive strength of the introduced similarity measures by using them directly as a recognition metric. Through validation, using both real and synthetic surveillance footage, our pose estimation method is shown to be accurate, and robust to lighting changes and image degradation.

  15. Accurate determination of characteristic relative permeability curves

    NASA Astrophysics Data System (ADS)

    Krause, Michael H.; Benson, Sally M.

    2015-09-01

    A recently developed technique to accurately characterize sub-core scale heterogeneity is applied to investigate the factors responsible for flowrate-dependent effective relative permeability curves measured on core samples in the laboratory. The dependency of laboratory measured relative permeability on flowrate has long been both supported and challenged by a number of investigators. Studies have shown that this apparent flowrate dependency is a result of both sub-core scale heterogeneity and outlet boundary effects. However this has only been demonstrated numerically for highly simplified models of porous media. In this paper, flowrate dependency of effective relative permeability is demonstrated using two rock cores, a Berea Sandstone and a heterogeneous sandstone from the Otway Basin Pilot Project in Australia. Numerical simulations of steady-state coreflooding experiments are conducted at a number of injection rates using a single set of input characteristic relative permeability curves. Effective relative permeability is then calculated from the simulation data using standard interpretation methods for calculating relative permeability from steady-state tests. Results show that simplified approaches may be used to determine flowrate-independent characteristic relative permeability provided flow rate is sufficiently high, and the core heterogeneity is relatively low. It is also shown that characteristic relative permeability can be determined at any typical flowrate, and even for geologically complex models, when using accurate three-dimensional models.

  16. Environmental Education: River Policy and Procedures.

    ERIC Educational Resources Information Center

    Snyder, Glenn; And Others

    Accurate as of October 1975, the guidebook establishes detailed procedures and policies to be used by all persons engaged in white water rafting trips involving students from Jefferson County (Colorado) Public Schools, and provides a general guide and set of instructions for anyone planning and carrying out such a trip. The guidelines are drawn…

  17. Accurate definition of brain regions position through the functional landmark approach.

    PubMed

    Thirion, Bertrand; Varoquaux, Gaël; Poline, Jean-Baptiste

    2010-01-01

    In many application of functional Magnetic Resonance Imaging (fMRI), including clinical or pharmacological studies, the definition of the location of the functional activity between subjects is crucial. While current acquisition and normalization procedures improve the accuracy of the functional signal localization, it is also important to ensure that functional foci detection yields accurate results, and reflects between-subject variability. Here we introduce a fast functional landmark detection procedure, that explicitly models the spatial variability of activation foci in the observed population. We compare this detection approach to standard statistical maps peak extraction procedures: we show that it yields more accurate results on simulations, and more reproducible results on a large cohort of subjects. These results demonstrate that explicit functional landmark modeling approaches are more effective than standard statistical mapping for brain functional focus detection. PMID:20879321

  18. Barriers to clinical translation with diagnostic drugs.

    PubMed

    Josephson, Lee; Rudin, Markus

    2013-03-01

    Radioactive imaging agents, like diagnostic drugs generally, undergo a drug development process that parallels that of therapeutic agents, with similar development times but substantially lower development costs and substantially smaller postapproval markets. Although rapid advances in genetic and expression profiling are furthering the development of expensive pharmacotherapies targeted to small patient populations, the commercial development of imaging agents for small patient populations is blocked by the limited revenues available with current per-dose pricing and the relatively small numbers of imaging procedures that would be performed. A wide-ranging discussion on the best approaches to allow new diagnostic imaging agents to become part of the health-care system, and benefit the patient, is needed. PMID:23359658

  19. Region of interest identification and diagnostic agreement in breast pathology.

    PubMed

    Nagarkar, Dilip B; Mercan, Ezgi; Weaver, Donald L; Brunyé, Tad T; Carney, Patricia A; Rendi, Mara H; Beck, Andrew H; Frederick, Paul D; Shapiro, Linda G; Elmore, Joann G

    2016-09-01

    A pathologist's accurate interpretation relies on identifying relevant histopathological features. Little is known about the precise relationship between feature identification and diagnostic decision making. We hypothesized that greater overlap between a pathologist's selected diagnostic region of interest (ROI) and a consensus derived ROI is associated with higher diagnostic accuracy. We developed breast biopsy test cases that included atypical ductal hyperplasia (n=80); ductal carcinoma in situ (n=78); and invasive breast cancer (n=22). Benign cases were excluded due to the absence of specific abnormalities. Three experienced breast pathologists conducted an independent review of the 180 digital whole slide images, established a reference consensus diagnosis and marked one or more diagnostic ROIs for each case. Forty-four participating pathologists independently diagnosed and marked ROIs on the images. Participant diagnoses and ROI were compared with consensus reference diagnoses and ROI. Regression models tested whether percent overlap between participant ROI and consensus reference ROI predicted diagnostic accuracy. Each of the 44 participants interpreted 39-50 cases for a total of 1972 individual diagnoses. Percent ROI overlap with the expert reference ROI was higher in pathologists who self-reported academic affiliation (69 vs 65%, P=0.002). Percent overlap between participants' ROI and consensus reference ROI was then classified into ordinal categories: 0, 1-33, 34-65, 66-99 and 100% overlap. For each incremental change in the ordinal percent ROI overlap, diagnostic agreement increased by 60% (OR 1.6, 95% CI (1.5-1.7), P<0.001) and the association remained significant even after adjustment for other covariates. The magnitude of the association between ROI overlap and diagnostic agreement increased with increasing diagnostic severity. The findings indicate that pathologists are more likely to converge with an expert reference diagnosis when they identify an

  20. Diagnostics and structure

    NASA Technical Reports Server (NTRS)

    Vial, J. C.

    1986-01-01

    The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation.

  1. Cardiovascular modeling and diagnostics

    SciTech Connect

    Kangas, L.J.; Keller, P.E.; Hashem, S.; Kouzes, R.T.

    1995-12-31

    In this paper, a novel approach to modeling and diagnosing the cardiovascular system is introduced. A model exhibits a subset of the dynamics of the cardiovascular behavior of an individual by using a recurrent artificial neural network. Potentially, a model will be incorporated into a cardiovascular diagnostic system. This approach is unique in that each cardiovascular model is developed from physiological measurements of an individual. Any differences between the modeled variables and the variables of an individual at a given time are used for diagnosis. This approach also exploits sensor fusion to optimize the utilization of biomedical sensors. The advantage of sensor fusion has been demonstrated in applications including control and diagnostics of mechanical and chemical processes.

  2. Nanodevices in diagnostics

    PubMed Central

    Hu, Ye; Fine, Daniel H.; Tasciotti, Ennio; Bouamrani, Ali; Ferrari, Mauro

    2010-01-01

    The real-time, personalized and highly sensitive early-stage diagnosis of disease remains an important challenge in modern medicine. With the ability to interact with matter at the nanoscale, the development of nanotechnology architectures and materials could potentially extend subcellular and molecular detection beyond the limits of conventional diagnostic modalities. At the very least, nanotechnology should be able to dramatically accelerate biomarker discovery, as well as facilitate disease monitoring, especially of maladies presenting a high degree of molecular and compositional heterogeneity. This article gives an overview of several of the most promising nanodevices and nanomaterials along with their applications in clinical practice. Significant work to adapt nanoscale materials and devices to clinical applications involving large interdisciplinary collaborations is already underway with the potential for nanotechnology to become an important enabling diagnostic technology. PMID:20229595

  3. Molecular diagnostics for tuberculosis.

    PubMed

    Noor, K M; Shephard, L; Bastian, I

    2015-04-01

    The phenotypic methods of smear microscopy, culture and indirect drug susceptibility testing (DST) remain the 'gold standard' diagnostics for tuberculosis (TB) in 2015. However, this review demonstrates that genotypic methods are in the ascendancy. Current-generation nucleic acid amplification tests (NAATs) are important supplementary tests for the rapid direct detection of (multidrug-resistant) TB in specific clinical settings. Genotypic detection is already the preferred method of detecting rifampicin and pyrazinamide resistance. Next-generation NAATs able to detect about 10 colony forming units/mL of sputum could replace culture as the initial test for detecting TB. Whole genome sequencing could also plausibly replace phenotypic DST but much work is required in method standardisation, database development and elucidation of all resistance gene determinants. The challenge then will be to rollout these increasingly complex and expensive diagnostics in the low-income countries where TB is prevalent. PMID:25719854

  4. Viral Hemorrhagic Fever Diagnostics.

    PubMed

    Racsa, Lori D; Kraft, Colleen S; Olinger, Gene G; Hensley, Lisa E

    2016-01-15

    There are 4 families of viruses that cause viral hemorrhagic fever (VHF), including Filoviridae. Ebola virus is one virus within the family Filoviridae and the cause of the current outbreak of VHF in West Africa. VHF-endemic areas are found throughout the world, yet traditional diagnosis of VHF has been performed in large reference laboratories centered in Europe and the United States. The large amount of capital needed, as well as highly trained and skilled personnel, has limited the availability of diagnostics in endemic areas except in conjunction with governmental and nongovernmental entities. However, rapid diagnosis of VHF is essential to efforts that will limit outbreaks. In addition, increased global travel suggests VHF diagnoses may be made outside of the endemic areas. Thus, understanding how to diagnose VHF is imperative for laboratories worldwide. This article reviews traditional and current diagnostic modalities for VHF. PMID:26354968

  5. TB diagnostic tests: how do we figure out their costs?

    PubMed

    Sohn, Hojoon; Minion, Jessica; Albert, Heidi; Dheda, Keertan; Pai, Madhukar

    2009-08-01

    Tuberculosis continues to be a major global health problem. Lack of accurate, rapid and cost-effective diagnostic tests poses a huge obstacle to global TB control. While several new diagnostic tools are being developed and evaluated for TB, it is important that new tools are introduced for widespread use only after careful validation of accuracy, impact as well as cost-effectiveness in real-world settings. While there are large numbers of studies on the accuracy of TB diagnostic tests, there are few studies that are focused on cost and cost-effectiveness. There are currently no widely accepted standards on how to evaluate costs of a TB test. In this review, we describe the basic approach for computing the costs of TB diagnostic tests, and provide templates for various data elements and parameters that go into the costing analysis. We hope this will pave the way for a standardized methodology for costing of TB diagnostic tests. Such a tool would enable improved and more generalizable costing analyses that can provide a strong foundation for more sophisticated economic analyses that evaluate the full economic and epidemiological impact resulting from the implementation and routine use of performance-verified new and innovative diagnostic tools. This, in turn, will facilitate evidence-based adoption and use of new diagnostics, especially in resource-limited settings. PMID:19681700

  6. Accurate Thermal Stresses for Beams: Normal Stress

    NASA Technical Reports Server (NTRS)

    Johnson, Theodore F.; Pilkey, Walter D.

    2003-01-01

    Formulations for a general theory of thermoelasticity to generate accurate thermal stresses for structural members of aeronautical vehicles were developed in 1954 by Boley. The formulation also provides three normal stresses and a shear stress along the entire length of the beam. The Poisson effect of the lateral and transverse normal stresses on a thermally loaded beam is taken into account in this theory by employing an Airy stress function. The Airy stress function enables the reduction of the three-dimensional thermal stress problem to a two-dimensional one. Numerical results from the general theory of thermoelasticity are compared to those obtained from strength of materials. It is concluded that the theory of thermoelasticity for prismatic beams proposed in this paper can be used instead of strength of materials when precise stress results are desired.

  7. Accurate Thermal Stresses for Beams: Normal Stress

    NASA Technical Reports Server (NTRS)

    Johnson, Theodore F.; Pilkey, Walter D.

    2002-01-01

    Formulations for a general theory of thermoelasticity to generate accurate thermal stresses for structural members of aeronautical vehicles were developed in 1954 by Boley. The formulation also provides three normal stresses and a shear stress along the entire length of the beam. The Poisson effect of the lateral and transverse normal stresses on a thermally loaded beam is taken into account in this theory by employing an Airy stress function. The Airy stress function enables the reduction of the three-dimensional thermal stress problem to a two-dimensional one. Numerical results from the general theory of thermoelasticity are compared to those obtained from strength of materials. It is concluded that the theory of thermoelasticity for prismatic beams proposed in this paper can be used instead of strength of materials when precise stress results are desired.

  8. Highly accurate articulated coordinate measuring machine

    DOEpatents

    Bieg, Lothar F.; Jokiel, Jr., Bernhard; Ensz, Mark T.; Watson, Robert D.

    2003-12-30

    Disclosed is a highly accurate articulated coordinate measuring machine, comprising a revolute joint, comprising a circular encoder wheel, having an axis of rotation; a plurality of marks disposed around at least a portion of the circumference of the encoder wheel; bearing means for supporting the encoder wheel, while permitting free rotation of the encoder wheel about the wheel's axis of rotation; and a sensor, rigidly attached to the bearing means, for detecting the motion of at least some of the marks as the encoder wheel rotates; a probe arm, having a proximal end rigidly attached to the encoder wheel, and having a distal end with a probe tip attached thereto; and coordinate processing means, operatively connected to the sensor, for converting the output of the sensor into a set of cylindrical coordinates representing the position of the probe tip relative to a reference cylindrical coordinate system.

  9. Practical aspects of spatially high accurate methods

    NASA Technical Reports Server (NTRS)

    Godfrey, Andrew G.; Mitchell, Curtis R.; Walters, Robert W.

    1992-01-01

    The computational qualities of high order spatially accurate methods for the finite volume solution of the Euler equations are presented. Two dimensional essentially non-oscillatory (ENO), k-exact, and 'dimension by dimension' ENO reconstruction operators are discussed and compared in terms of reconstruction and solution accuracy, computational cost and oscillatory behavior in supersonic flows with shocks. Inherent steady state convergence difficulties are demonstrated for adaptive stencil algorithms. An exact solution to the heat equation is used to determine reconstruction error, and the computational intensity is reflected in operation counts. Standard MUSCL differencing is included for comparison. Numerical experiments presented include the Ringleb flow for numerical accuracy and a shock reflection problem. A vortex-shock interaction demonstrates the ability of the ENO scheme to excel in simulating unsteady high-frequency flow physics.

  10. The thermodynamic cost of accurate sensory adaptation

    NASA Astrophysics Data System (ADS)

    Tu, Yuhai

    2015-03-01

    Living organisms need to obtain and process environment information accurately in order to make decisions critical for their survival. Much progress have been made in identifying key components responsible for various biological functions, however, major challenges remain to understand system-level behaviors from the molecular-level knowledge of biology and to unravel possible physical principles for the underlying biochemical circuits. In this talk, we will present some recent works in understanding the chemical sensory system of E. coli by combining theoretical approaches with quantitative experiments. We focus on addressing the questions on how cells process chemical information and adapt to varying environment, and what are the thermodynamic limits of key regulatory functions, such as adaptation.

  11. Accurate numerical solutions of conservative nonlinear oscillators

    NASA Astrophysics Data System (ADS)

    Khan, Najeeb Alam; Nasir Uddin, Khan; Nadeem Alam, Khan

    2014-12-01

    The objective of this paper is to present an investigation to analyze the vibration of a conservative nonlinear oscillator in the form u" + lambda u + u^(2n-1) + (1 + epsilon^2 u^(4m))^(1/2) = 0 for any arbitrary power of n and m. This method converts the differential equation to sets of algebraic equations and solve numerically. We have presented for three different cases: a higher order Duffing equation, an equation with irrational restoring force and a plasma physics equation. It is also found that the method is valid for any arbitrary order of n and m. Comparisons have been made with the results found in the literature the method gives accurate results.

  12. Accurate metacognition for visual sensory memory representations.

    PubMed

    Vandenbroucke, Annelinde R E; Sligte, Ilja G; Barrett, Adam B; Seth, Anil K; Fahrenfort, Johannes J; Lamme, Victor A F

    2014-04-01

    The capacity to attend to multiple objects in the visual field is limited. However, introspectively, people feel that they see the whole visual world at once. Some scholars suggest that this introspective feeling is based on short-lived sensory memory representations, whereas others argue that the feeling of seeing more than can be attended to is illusory. Here, we investigated this phenomenon by combining objective memory performance with subjective confidence ratings during a change-detection task. This allowed us to compute a measure of metacognition--the degree of knowledge that subjects have about the correctness of their decisions--for different stages of memory. We show that subjects store more objects in sensory memory than they can attend to but, at the same time, have similar metacognition for sensory memory and working memory representations. This suggests that these subjective impressions are not an illusion but accurate reflections of the richness of visual perception. PMID:24549293

  13. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, Douglas D.

    1985-01-01

    The present invention is a thermometer used for measuring furnace temperaes in the range of about 1800.degree. to 2700.degree. C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  14. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  15. Toward Accurate and Quantitative Comparative Metagenomics.

    PubMed

    Nayfach, Stephen; Pollard, Katherine S

    2016-08-25

    Shotgun metagenomics and computational analysis are used to compare the taxonomic and functional profiles of microbial communities. Leveraging this approach to understand roles of microbes in human biology and other environments requires quantitative data summaries whose values are comparable across samples and studies. Comparability is currently hampered by the use of abundance statistics that do not estimate a meaningful parameter of the microbial community and biases introduced by experimental protocols and data-cleaning approaches. Addressing these challenges, along with improving study design, data access, metadata standardization, and analysis tools, will enable accurate comparative metagenomics. We envision a future in which microbiome studies are replicable and new metagenomes are easily and rapidly integrated with existing data. Only then can the potential of metagenomics for predictive ecological modeling, well-powered association studies, and effective microbiome medicine be fully realized. PMID:27565341

  16. PML diagnostic criteria

    PubMed Central

    Aksamit, Allen J.; Clifford, David B.; Davis, Larry; Koralnik, Igor J.; Sejvar, James J.; Bartt, Russell; Major, Eugene O.; Nath, Avindra

    2013-01-01

    Objective: To establish criteria for the diagnosis of progressive multifocal leukoencephalopathy (PML). Methods: We reviewed available literature to identify various diagnostic criteria employed. Several search strategies employing the terms “progressive multifocal leukoencephalopathy” with or without “JC virus” were performed with PubMed, SCOPUS, and EMBASE search engines. The articles were reviewed by a committee of individuals with expertise in the disorder in order to determine the most useful applicable criteria. Results: A consensus statement was developed employing clinical, imaging, pathologic, and virologic evidence in support of the diagnosis of PML. Two separate pathways, histopathologic and clinical, for PML diagnosis are proposed. Diagnostic classification includes certain, probable, possible, and not PML. Conclusion: Definitive diagnosis of PML requires neuropathologic demonstration of the typical histopathologic triad (demyelination, bizarre astrocytes, and enlarged oligodendroglial nuclei) coupled with the techniques to show the presence of JC virus. The presence of clinical and imaging manifestations consistent with the diagnosis and not better explained by other disorders coupled with the demonstration of JC virus by PCR in CSF is also considered diagnostic. Algorithms for establishing the diagnosis have been recommended. PMID:23568998

  17. Upgrading Diagnostic Diagrams

    NASA Astrophysics Data System (ADS)

    Proxauf, B.; Kimeswenger, S.; Öttl, S.

    2014-04-01

    Diagnostic diagrams of forbidden lines have been a useful tool for observers in astrophysics for many decades now. They are used to obtain information on the basic physical properties of thin gaseous nebulae. Moreover they are also the initial tool to derive thermodynamic properties of the plasma from observations to get ionization correction factors and thus to obtain proper abundances of the nebulae. Some diagnostic diagrams are in wavelengths domains which were difficult to take either due to missing wavelength coverage or low resolution of older spectrographs. Thus they were hardly used in the past. An upgrade of this useful tool is necessary because most of the diagrams were calculated using only the species involved as a single atom gas, although several are affected by well-known fluorescence mechanisms as well. Additionally the atomic data have improved up to the present time. The new diagnostic diagrams are calculated by using large grids of parameter space in the photoionization code CLOUDY. For a given basic parameter the input radiation field is varied to find the solutions with cooling-heating-equilibrium. Empirical numerical functions are fitted to provide formulas usable in e.g. data reduction pipelines. The resulting diagrams differ significantly from those used up to now and will improve the thermodynamic calculations.

  18. Verifying Diagnostic Software

    NASA Technical Reports Server (NTRS)

    Lindsey, Tony; Pecheur, Charles

    2004-01-01

    Livingstone PathFinder (LPF) is a simulation-based computer program for verifying autonomous diagnostic software. LPF is designed especially to be applied to NASA s Livingstone computer program, which implements a qualitative-model-based algorithm that diagnoses faults in a complex automated system (e.g., an exploratory robot, spacecraft, or aircraft). LPF forms a software test bed containing a Livingstone diagnosis engine, embedded in a simulated operating environment consisting of a simulator of the system to be diagnosed by Livingstone and a driver program that issues commands and faults according to a nondeterministic scenario provided by the user. LPF runs the test bed through all executions allowed by the scenario, checking for various selectable error conditions after each step. All components of the test bed are instrumented, so that execution can be single-stepped both backward and forward. The architecture of LPF is modular and includes generic interfaces to facilitate substitution of alternative versions of its different parts. Altogether, LPF provides a flexible, extensible framework for simulation-based analysis of diagnostic software; these characteristics also render it amenable to application to diagnostic programs other than Livingstone.

  19. [Acromegaly: reducing diagnostic delay].

    PubMed

    Giustina, Andrea

    2016-08-01

    Diagnostic delay of acromegaly is still very relevant (6-8 years on average) without substantial changes in last twenty years. Clinical impact of this diagnostic delay is significant: tumor growth (2/3 of the patients at diagnosis bear a pituitary macroadenoma), development of irreversible complications (arthropathy, sleep apnea) and in all increased mortality. Reasons for this delay are related to the disease itself (facial and acral changes are very slow and subtle) but also to medical unawareness. Simple tools based on a few sufficiently sensitive and specific signs and symptoms which can trigger the diagnostic suspect would be useful in clinical practice. Global evaluation during follow-up (tumor volume, signs and symptoms, complications, circulating levels of growth hormone and its peripheral mediator IGF-I) has become crucial for the therapeutic decision making. In this regard, tools like SAGIT are now under validation and are expected to improve management of acromegaly. In fact, in the last 30 years there has been a relevant growth of the medical options to treat acromegaly and in the near future there will be an expansion of the medical options. This will greatly help the needed personalization of treatment which necessarily should consider patient convenience and preference and control of complications such as diabetes mellitus. PMID:27571562

  20. Microgravity Combustion Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Santoro, Gilbert J. (Editor); Greenberg, Paul S. (Editor); Piltch, Nancy D. (Editor)

    1988-01-01

    Through the Microgravity Science and Applications Division (MSAD) of the Office of Space Science and Applications (OSSA) at NASA Headquarters, a program entitled, Advanced Technology Development (ATD) was promulgated with the objective of providing advanced technologies that will enable the development of future microgravity science and applications experimental flight hardware. Among the ATD projects one, Microgravity Combustion Diagnostics (MCD), has the objective of developing advanced diagnostic techniques and technologies to provide nonperturbing measurements of combustion characteristics and parameters that will enhance the scientific integrity and quality of microgravity combustion experiments. As part of the approach to this project, a workshop was held on July 28 and 29, 1987, at the NASA Lewis Research Center. A small group of laser combustion diagnosticians met with a group of microgravity combustion experimenters to discuss the science requirements, the state-of-the-art of laser diagnostic technology, and plan the direction for near-, intermediate-, and long-term programs. This publication describes the proceedings of that workshop.

  1. Microsphere based saliva diagnostics

    NASA Astrophysics Data System (ADS)

    Rissin, David M.; DiCesare, Christopher; Hayman, Ryan B.; Blicharz, Timothy M.; Walt, David R.

    2005-11-01

    Saliva presents a minimally invasive alternative medium to blood for performing diagnostics1. Microsphere sensors for ions, small organic molecules, and proteins are currently being developed and optical microarrays containing thousands of these sensors will be used for simultaneous multi-analyte analysis. The fiber bundle platform in use is 1mm in diameter and contains approximately 50,000 individually addressable 3.1μm fibers, each with an etched well capable of housing a single 3.1μm microsphere sensor. Micron-sized bead-based chemistries are produced in house, followed by deposition onto a fiber-optic bundle platform, allowing for multiplexed analysis. The ultimate goal is to develop a universal diagnostic system using saliva as the diagnostic medium. This platform will permit multiplexed analysis of a sample by integrating microfluidics with the optical arrays loaded with sensors capable of detecting relevant biomarkers associated with a wide range of disease states. Disease states that are currently under investigation include end stage renal disease (ESRD) and Sjoegrens Syndrome (SS).

  2. [Spectrum diagnostic of arcjet].

    PubMed

    Zhao, Wen-Hua; Shen, Yan; Chen, Li-Ming

    2004-08-01

    Arcjet is a kind of propulsion device for mechanical operation and control of spacecraft. As its specific impulse is far greater than classical device using chemical propellant, arcjet is playing an increasing role in spacecraft propulsion. To improve our understanding of its working mechanics, the diagnostic method of arcjet is discussed and a set of spectrum diagnostic system is established in this paper. With this system, spectrum diagnostic was executed for Ar propellant at a setting value of flow rate and input current in a vacuum chamber. The result shows that the system has a high signal-to-noise ratio and the data collected can reflect the physical process objectively. Through transaction and analysis of these data, radial distribution of emission coefficient was obtained for different spectral lines, and radial distribution of temperature was also obtained through farther analysis of the emission coefficient. The result shows that under the experiment conditions of this paper, arcjet is in thermodynamic non-equilibrium state, therefore the temperatures obtained by different spectral lines are different. PMID:15766102

  3. ITER Diagnostic First Wal

    SciTech Connect

    G. Douglas Loesser, et. al.

    2012-09-21

    The ITER Diagnostic Division is responsible for designing and procuring the First Wall Blankets that are mounted on the vacuum vessel port plugs at both the upper and equatorial levels This paper will discuss the effects of the diagnostic aperture shape and configuration on the coolant circuit design. The DFW design is driven in large part by the need to conform the coolant arrangement to a wide variety of diagnostic apertures combined with the more severe heating conditions at the surface facing the plasma, the first wall. At the first wall, a radiant heat flux of 35W/cm2 combines with approximate peak volumetric heating rates of 8W/cm3 (equatorial ports) and 5W/cm3 (upper ports). Here at the FW, a fast thermal response is desirable and leads to a thin element between the heat flux and coolant. This requirement is opposed by the wish for a thicker FW element to accommodate surface erosion and other off-normal plasma events.

  4. Alpha Particle Diagnostic

    SciTech Connect

    Fisher, Ray, K.

    2009-05-13

    The study of burning plasmas is the next frontier in fusion energy research, and will be a major objective of the U.S. fusion program through U.S. collaboration with our international partners on the ITER Project. For DT magnetic fusion to be useful for energy production, it is essential that the energetic alpha particles produced by the fusion reactions be confined long enough to deposit a significant fraction of their initial ~3.5 MeV energy in the plasma before they are lost. Development of diagnostics to study the behavior of energetic confined alpha particles is a very important if not essential part of burning plasma research. Despite the clear need for these measurements, development of diagnostics to study confined the fast confined alphas to date has proven extremely difficult, and the available techniques remain for the most part unproven and with significant uncertainties. Research under this grant had the goal of developing diagnostics of fast confined alphas, primarily based on measurements of the neutron and ion tails resulting from alpha particle knock-on collisions with the plasma deuterium and tritium fuel ions. One of the strengths of this approach is the ability to measure the alphas in the hot plasma core where the interesting ignition physics will occur.

  5. The importance of accurate atmospheric modeling

    NASA Astrophysics Data System (ADS)

    Payne, Dylan; Schroeder, John; Liang, Pang

    2014-11-01

    This paper will focus on the effect of atmospheric conditions on EO sensor performance using computer models. We have shown the importance of accurately modeling atmospheric effects for predicting the performance of an EO sensor. A simple example will demonstrated how real conditions for several sites in China will significantly impact on image correction, hyperspectral imaging, and remote sensing. The current state-of-the-art model for computing atmospheric transmission and radiance is, MODTRAN® 5, developed by the US Air Force Research Laboratory and Spectral Science, Inc. Research by the US Air Force, Navy and Army resulted in the public release of LOWTRAN 2 in the early 1970's. Subsequent releases of LOWTRAN and MODTRAN® have continued until the present. Please verify that (1) all pages are present, (2) all figures are correct, (3) all fonts and special characters are correct, and (4) all text and figures fit within the red margin lines shown on this review document. Complete formatting information is available at http://SPIE.org/manuscripts Return to the Manage Active Submissions page at http://spie.org/submissions/tasks.aspx and approve or disapprove this submission. Your manuscript will not be published without this approval. Please contact author_help@spie.org with any questions or concerns. The paper will demonstrate the importance of using validated models and local measured meteorological, atmospheric and aerosol conditions to accurately simulate the atmospheric transmission and radiance. Frequently default conditions are used which can produce errors of as much as 75% in these values. This can have significant impact on remote sensing applications.

  6. The high cost of accurate knowledge.

    PubMed

    Sutcliffe, Kathleen M; Weber, Klaus

    2003-05-01

    Many business thinkers believe it's the role of senior managers to scan the external environment to monitor contingencies and constraints, and to use that precise knowledge to modify the company's strategy and design. As these thinkers see it, managers need accurate and abundant information to carry out that role. According to that logic, it makes sense to invest heavily in systems for collecting and organizing competitive information. Another school of pundits contends that, since today's complex information often isn't precise anyway, it's not worth going overboard with such investments. In other words, it's not the accuracy and abundance of information that should matter most to top executives--rather, it's how that information is interpreted. After all, the role of senior managers isn't just to make decisions; it's to set direction and motivate others in the face of ambiguities and conflicting demands. Top executives must interpret information and communicate those interpretations--they must manage meaning more than they must manage information. So which of these competing views is the right one? Research conducted by academics Sutcliffe and Weber found that how accurate senior executives are about their competitive environments is indeed less important for strategy and corresponding organizational changes than the way in which they interpret information about their environments. Investments in shaping those interpretations, therefore, may create a more durable competitive advantage than investments in obtaining and organizing more information. And what kinds of interpretations are most closely linked with high performance? Their research suggests that high performers respond positively to opportunities, yet they aren't overconfident in their abilities to take advantage of those opportunities. PMID:12747164

  7. Accurate Weather Forecasting for Radio Astronomy

    NASA Astrophysics Data System (ADS)

    Maddalena, Ronald J.

    2010-01-01

    The NRAO Green Bank Telescope routinely observes at wavelengths from 3 mm to 1 m. As with all mm-wave telescopes, observing conditions depend upon the variable atmospheric water content. The site provides over 100 days/yr when opacities are low enough for good observing at 3 mm, but winds on the open-air structure reduce the time suitable for 3-mm observing where pointing is critical. Thus, to maximum productivity the observing wavelength needs to match weather conditions. For 6 years the telescope has used a dynamic scheduling system (recently upgraded; www.gb.nrao.edu/DSS) that requires accurate multi-day forecasts for winds and opacities. Since opacity forecasts are not provided by the National Weather Services (NWS), I have developed an automated system that takes available forecasts, derives forecasted opacities, and deploys the results on the web in user-friendly graphical overviews (www.gb.nrao.edu/ rmaddale/Weather). The system relies on the "North American Mesoscale" models, which are updated by the NWS every 6 hrs, have a 12 km horizontal resolution, 1 hr temporal resolution, run to 84 hrs, and have 60 vertical layers that extend to 20 km. Each forecast consists of a time series of ground conditions, cloud coverage, etc, and, most importantly, temperature, pressure, humidity as a function of height. I use the Liebe's MWP model (Radio Science, 20, 1069, 1985) to determine the absorption in each layer for each hour for 30 observing wavelengths. Radiative transfer provides, for each hour and wavelength, the total opacity and the radio brightness of the atmosphere, which contributes substantially at some wavelengths to Tsys and the observational noise. Comparisons of measured and forecasted Tsys at 22.2 and 44 GHz imply that the forecasted opacities are good to about 0.01 Nepers, which is sufficient for forecasting and accurate calibration. Reliability is high out to 2 days and degrades slowly for longer-range forecasts.

  8. Minimally invasive procedures for neuropathic pain.

    PubMed

    Sdrulla, Andrei; Chen, Grace

    2016-04-01

    Neuropathic pain is "pain arising as a direct consequence of a lesion or disease affecting the somatosensory system". The prevalence of neuropathic pain ranges from 7 to 11% of the population and minimally invasive procedures have been used to both diagnose and treat neuropathic pain. Diagnostic procedures consist of nerve blocks aimed to isolate the peripheral nerve implicated, whereas therapeutic interventions either modify or destroy nerve function. Procedures that modify how nerves function include epidural steroid injections, peripheral nerve blocks and sympathetic nerve blocks. Neuroablative procedures include radiofrequency ablation, cryoanalgesia and neurectomies. Currently, neuromodulation with peripheral nerve stimulators and spinal cord stimulators are the most evidence-based treatments of neuropathic pain. PMID:26988024

  9. Troubleshooting the diagnostic conundrums

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Because so many different clinical presentations can be associated with infection with BVDV, diagnosis based on history, clinical presentation, and postmortem of affected animals is presumptive at best. Accurate and definitive detection of infection with BVDV depends on laboratory diagnosis. While t...

  10. [Priapism: Current diagnostics and therapy].

    PubMed

    Bschleipfer, T; Schwindl, B; Klotz, T

    2015-11-01

    Priapism is characterized by involuntary persistent penile erection after or independent of sexual stimulation. The diagnostic clarification, including patient history, physical findings, duplex ultrasonography and analysis of blood gases is decisive for the underlying pathophysiology and the appropriate therapeutic procedure. Non-hypoxic and non-acidotic blood gas parameters enable a conservative approach, hypoxic, hypercarbic and acidotic parameters may lead to fibrosis of the corpora cavernosa and, in turn, to a loss of penile function. Low-flow or ischemic (veno-occlusive) priapism is an emergency situation and can lead to irreversible erectile dysfunction within 4 h. Treatment consists of blood aspiration and possibly intracavernosal injection of sympathomimetic drugs. A distal shunt is necessary in the case of treatment failure (in rare cases a proximal shunt). Management of recurrent priapism (stuttering) includes self-injection of sympathomimetic drugs and preventive long-term administration of erection inhibitory and erection promoting substances. This concept still needs to be validated. High-flow or non-ischemic priapism does not necessitate immediate treatment measures and should be kept under observation. In cases of a detectable fistula selective artery embolization is often a successful option. PMID:26573674

  11. Obturator hernia: A diagnostic challenge

    PubMed Central

    Tokushima, Midori; Aihara, Hidetoshi; Tago, Masaki; Tomonaga, Motosuke; Sakanishi, Yuta; Yoshioka, Tsuneaki; Hyakutake, Masaki; Kyoraku, Itaru; Sugioka, Takashi; Yamashita, Shu-ichi

    2014-01-01

    Patient: Female, 90 Final Diagnosis: Obturator hernia Symptoms: Epigastric pain • vomiting Medication: — Clinical Procedure: — Specialty: Gastroenterology and Hepatology Objective: Challenging differential diagnosis Background: Obturator hernia (OH) can be difficult to diagnose because it shows only nonspecific signs and symptoms. Although pain in a lower limb caused by compression of the obturator nerve by the hernia in the obturator canal (Howship-Romberg sign) is a characteristic sign, its presence is rather rare. Case Report: We herein describe the case of a 90-year-old woman with an OH that was difficult to diagnose because of her slight abdominal signs and symptoms on admission and subtle abdominal computed tomography (CT) findings. Although the CT images revealed the presence of an OH, this finding was overlooked because it contained only a part of the small intestine wall, which is called the Richter type. Fortunately, her condition improved dramatically with only conservative treatment. Conclusions: Although early diagnosis is essential to reduce morbidity and mortality, OH can be a diagnostic challenge even with abdominal CT. PMID:25006359

  12. Approaching system equilibrium with accurate or not accurate feedback information in a two-route system

    NASA Astrophysics Data System (ADS)

    Zhao, Xiao-mei; Xie, Dong-fan; Li, Qi

    2015-02-01

    With the development of intelligent transport system, advanced information feedback strategies have been developed to reduce traffic congestion and enhance the capacity. However, previous strategies provide accurate information to travelers and our simulation results show that accurate information brings negative effects, especially in delay case. Because travelers prefer to the best condition route with accurate information, and delayed information cannot reflect current traffic condition but past. Then travelers make wrong routing decisions, causing the decrease of the capacity and the increase of oscillations and the system deviating from the equilibrium. To avoid the negative effect, bounded rationality is taken into account by introducing a boundedly rational threshold BR. When difference between two routes is less than the BR, routes have equal probability to be chosen. The bounded rationality is helpful to improve the efficiency in terms of capacity, oscillation and the gap deviating from the system equilibrium.

  13. Diagnostics for fast ignition science (invited)

    SciTech Connect

    MacPhee, A. G.; Chen, C. D.; Chen, H.; Hey, D. S.; Kemp, A. J.; Key, M. H.; Le Pape, S.; Patel, P. K.; Phillips, T. W.; Town, R.; Mackinnon, A. J.; Akli, K. U.; Stephens, R. B.; Beg, F. N.; King, J. A.; Ma, T. Y.; Wei, M. S.; Clarke, R.; Freeman, R. R.; Link, A.

    2008-10-15

    The ignition concept for electron fast ignition inertial confinement fusion requires sufficient energy be transferred from an {approx}20 ps laser pulse to the compressed fuel via approximately MeV electrons. We have assembled a suite of diagnostics to characterize such transfer, simultaneously fielding absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256 eV; spherically bent crystal imagers at 4.5 and 8 keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung, electron and proton spectrometers (along the same line of sight), and a picosecond optical probe interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following the laser-plasma interactions at extremely high intensities in both planar and conical targets. Together with accurate on-shot laser focal spot and prepulse characterization, these measurements are yielding new insights into energy coupling and are providing critical data for validating numerical particle-in-cell (PIC) and hybrid PIC simulation codes in an area crucial for fast ignition and other applications. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultrahigh intensity laser-plasma interactions are discussed.

  14. Microfluidic diagnostics for low-resource settings

    NASA Astrophysics Data System (ADS)

    Hawkins, Kenneth R.; Weigl, Bernhard H.

    2010-02-01

    Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.

  15. Two new diagnostics of dark energy

    SciTech Connect

    Sahni, Varun; Shafieloo, Arman; Starobinsky, Alexei A.

    2008-11-15

    We introduce two new diagnostics of dark energy (DE). The first, Om, is a combination of the Hubble parameter and the cosmological redshift and provides a null test of dark energy being a cosmological constant {lambda}. Namely, if the value of Om(z) is the same at different redshifts, then DE{identical_to}{lambda}, exactly. The slope of Om(z) can differentiate between different models of dark energy even if the value of the matter density is not accurately known. For DE with an unevolving equation of state, a positive slope of Om(z) is suggestive of phantom (w<-1) while a negative slope indicates quintessence (w>-1). The second diagnostic--acceleration probe q--is the mean value of the deceleration parameter over a small redshift range. It can be used to determine the cosmological redshift at which the universe began to accelerate, again without reference to the current value of the matter density. We apply the Om and q diagnostics to the Union data set of type Ia supernovae combined with recent data from the cosmic microwave background (Wilkinson Microwave Anisotropy Probe 5) and baryon acoustic oscillations.

  16. Diagnostics for fast ignition science (invited).

    PubMed

    MacPhee, A G; Akli, K U; Beg, F N; Chen, C D; Chen, H; Clarke, R; Hey, D S; Freeman, R R; Kemp, A J; Key, M H; King, J A; Le Pape, S; Link, A; Ma, T Y; Nakamura, H; Offermann, D T; Ovchinnikov, V M; Patel, P K; Phillips, T W; Stephens, R B; Town, R; Tsui, Y Y; Wei, M S; Van Woerkom, L D; Mackinnon, A J

    2008-10-01

    The ignition concept for electron fast ignition inertial confinement fusion requires sufficient energy be transferred from an approximately 20 ps laser pulse to the compressed fuel via approximately MeV electrons. We have assembled a suite of diagnostics to characterize such transfer, simultaneously fielding absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256 eV; spherically bent crystal imagers at 4.5 and 8 keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung, electron and proton spectrometers (along the same line of sight), and a picosecond optical probe interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following the laser-plasma interactions at extremely high intensities in both planar and conical targets. Together with accurate on-shot laser focal spot and prepulse characterization, these measurements are yielding new insights into energy coupling and are providing critical data for validating numerical particle-in-cell (PIC) and hybrid PIC simulation codes in an area crucial for fast ignition and other applications. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultrahigh intensity laser-plasma interactions are discussed. PMID:19044615

  17. Procedures at NREL for Evaluating Multijunction Concentrator Cells

    SciTech Connect

    Moriarty, T.; Emery, K.

    2000-01-01

    The procedures for evaluating the performance of multijunctiion-concentrator cells at the National Renewable Energy Laboratory are described. The accurate measurement of the performance of multijunction cells requires accurate relative-quantum-efficiency-measurements, "matched" reference cells, and a spectrally adjustable solar simulator.

  18. In vivo diagnostic nuclear medicine. Pediatric experience

    SciTech Connect

    Goetz, W.A.; Hendee, W.R.; Gilday, D.L.

    1983-09-01

    The use of radiopharmaceuticals for diagnostic tests in children is increasing and interest in these is evidenced by the addition of scientific sessions devoted to pediatric medicine at annual meetings of The Society of Nuclear Medicine and by the increase in the literature on pediatric dosimetry. Data presented in this paper describe the actual pediatric nuclear medicine experience from 26 nationally representative U.S. hospitals and provide an overview of the pediatric procedures being performed the types of radiopharmaceuticals being used, and the activity levels being administered.

  19. Diagnostic, treatment, and surgical imaging in epilepsy.

    PubMed

    Nagae, Lidia Mayumi; Lall, Neil; Dahmoush, Hisham; Nyberg, Eric; Mirsky, David; Drees, Cornelia; Honce, Justin M

    2016-01-01

    Dedicated epilepsy centers are growing in hospitals throughout the USA and abroad, with a continuously increasing role of imaging in multidisciplinary meetings. Imaging is paramount in diagnosis, treatment, and surgical decision-making in lesional and nonlesional epileptic disease. Besides being up-to-date with technical developments in imaging that may make an impact in patient care, familiarity with clinical and surgical aspects of epilepsy is fundamental to better understanding of patient management. The present article intends to revisit diagnostic, therapeutic, and surgical imaging in epilepsy. Finally, with the increase in frequency of epilepsy management-related procedures and their hardware, MRI safety issues are discussed. PMID:27317207

  20. Photovoltaic array space power plus diagnostics experiment

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1990-01-01

    The objective is to summarize the five years of hardware development and fabrication represented by the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) Instrument. The original PASP Experiment requirements and background is presented along with the modifications which were requested to transform the PASP Experiment into the PASP Plus Instrument. The PASP Plus hardware and software is described. Test results for components and subsystems are given as well as final system tests. Also included are appendices which describe the major subsystems and present supporting documentation such as block diagrams, schematics, circuit board artwork, drawings, test procedures and test reports.

  1. Problems with diagnostic criteria for depression.

    PubMed

    Carroll, B J

    1984-07-01

    Limitations of the three major psychiatric diagnostic systems are discussed, with particular reference to depression and its subtypes. The lack of demonstrated reliability and validity for standard diagnoses, and the use of these diagnoses as independent variables in clinical research, is criticized. Possible approaches to improving current classification methods include increased specificity and sensitivity of symptoms, differential weighting, and objective recording. Scientific validation procedures should be applied to the classification of depressions, including studies of natural history and course, specific antidepressant drug responses, and the use of laboratory markers such as the dexamethasone suppression test and sleep EEG parameters. PMID:6376481

  2. Higher order accurate partial implicitization: An unconditionally stable fourth-order-accurate explicit numerical technique

    NASA Technical Reports Server (NTRS)

    Graves, R. A., Jr.

    1975-01-01

    The previously obtained second-order-accurate partial implicitization numerical technique used in the solution of fluid dynamic problems was modified with little complication to achieve fourth-order accuracy. The Von Neumann stability analysis demonstrated the unconditional linear stability of the technique. The order of the truncation error was deduced from the Taylor series expansions of the linearized difference equations and was verified by numerical solutions to Burger's equation. For comparison, results were also obtained for Burger's equation using a second-order-accurate partial-implicitization scheme, as well as the fourth-order scheme of Kreiss.

  3. Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua

    2012-01-01

    This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…

  4. Assessing Fit of Cognitive Diagnostic Models: A Case Study

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Almond, Russell G.

    2007-01-01

    A cognitive diagnostic model uses information from educational experts to describe the relationships between item performances and posited proficiencies. When the cognitive relationships can be described using a fully Bayesian model, Bayesian model checking procedures become available. Checking models tied to cognitive theory of the domains…

  5. Diagnostic utility of cholescintigraphy and ultrasonography in acute cholecystitis

    SciTech Connect

    Zeman, R.K.; Burrell, M.I.; Cahow, C.E.; Caride, V.

    1981-04-01

    When faced with a patient with possible acute cholecystitis, technetium-99m-HIDA scintigraphy should be the primary diagnostic procedure performed. If scintigraphy reveals a normal gallbladder, acute cholecystitis is excluded. If the scintigram fails to visualize the gallbladder, ultrasonography is deemed advisable to exclude potential false-positive scintigrams and confirm the presence of cholelithiasis.

  6. RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 2. APPENDICES

    EPA Science Inventory

    The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...

  7. Measurement of patient radiation doses in certain urography procedures.

    PubMed

    Sulieman, A; Barakat, H; Zailae, A; Abuderman, A; Theodorou, K

    2015-07-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urologic procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. PMID:25899610

  8. Accurate Measurement of Organic Solar Cell Efficiency

    SciTech Connect

    Emery, K.; Moriarty, T.

    2008-01-01

    We discuss the measurement and analysis of current vs. voltage (I-V) characteristics of organic and dye-sensitized photovoltaic cells and modules. A brief discussion of the history of photovoltaic efficiency measurements and procedures will be presented. We discuss both the error sources in the measurements and the strategies to minimize their influence. These error sources include the sample area, spectral errors, temperature fluctuations, current and voltage response time, contacting, and degradation during testing. Information that can be extracted from light and dark I-V measurement includes peak power, open-circuit voltage, short-circuit current, series and shunt resistance, diode quality factor, dark current, and photo-current. The quantum efficiency provides information on photo-current nonlinearities, current generation, and recombination mechanisms.

  9. Accurate, fully-automated NMR spectral profiling for metabolomics.

    PubMed

    Ravanbakhsh, Siamak; Liu, Philip; Bjorndahl, Trent C; Bjordahl, Trent C; Mandal, Rupasri; Grant, Jason R; Wilson, Michael; Eisner, Roman; Sinelnikov, Igor; Hu, Xiaoyu; Luchinat, Claudio; Greiner, Russell; Wishart, David S

    2015-01-01

    Many diseases cause significant changes to the concentrations of small molecules (a.k.a. metabolites) that appear in a person's biofluids, which means such diseases can often be readily detected from a person's "metabolic profile"-i.e., the list of concentrations of those metabolites. This information can be extracted from a biofluids Nuclear Magnetic Resonance (NMR) spectrum. However, due to its complexity, NMR spectral profiling has remained manual, resulting in slow, expensive and error-prone procedures that have hindered clinical and industrial adoption of metabolomics via NMR. This paper presents a system, BAYESIL, which can quickly, accurately, and autonomously produce a person's metabolic profile. Given a 1D 1H NMR spectrum of a complex biofluid (specifically serum or cerebrospinal fluid), BAYESIL can automatically determine the metabolic profile. This requires first performing several spectral processing steps, then matching the resulting spectrum against a reference compound library, which contains the "signatures" of each relevant metabolite. BAYESIL views spectral matching as an inference problem within a probabilistic graphical model that rapidly approximates the most probable metabolic profile. Our extensive studies on a diverse set of complex mixtures including real biological samples (serum and CSF), defined mixtures and realistic computer generated spectra; involving > 50 compounds, show that BAYESIL can autonomously find the concentration of NMR-detectable metabolites accurately (~ 90% correct identification and ~ 10% quantification error), in less than 5 minutes on a single CPU. These results demonstrate that BAYESIL is the first fully-automatic publicly-accessible system that provides quantitative NMR spectral profiling effectively-with an accuracy on these biofluids that meets or exceeds the performance of trained experts. We anticipate this tool will usher in high-throughput metabolomics and enable a wealth of new applications of NMR in

  10. Experiences of non-navigated women undergoing breast diagnostic evaluation.

    PubMed

    Harding, Mariann M; McCrone, Susan

    2013-02-01

    During the diagnostic period, women need appropriate, timely information regarding tests and procedures. Nurse navigator programs were developed to combat the negative effects on survival that are caused by delays in the diagnosis of breast cancer and lack of support from the healthcare team. Nurse navigators decreased barriers to care, increased patient satisfaction, and lowered anxiety in women undergoing diagnostic evaluation. However, although patient navigation programs have become a presence in oncology centers, those programs and the accompanying support are not offered at every facility that provides components of diagnostic evaluation. Therefore, the purpose of the current study was to explore the experiences of women who underwent a breast diagnostic evaluation without any accompanying navigation services. PMID:23372108

  11. Diagnostics for studies of novel laser ion acceleration mechanisms

    SciTech Connect

    Senje, Lovisa; Aurand, Bastian; Wahlström, Claes-Göran; Yeung, Mark; Kuschel, Stephan; Rödel, Christian; Wagner, Florian; Roth, Markus; Li, Kun; Neumayer, Paul; Dromey, Brendan; Jung, Daniel; Bagnoud, Vincent; Zepf, Matthew; Kuehl, Thomas

    2014-11-15

    Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.

  12. A mid-infrared absorption diagnostic for acetylene detection

    NASA Astrophysics Data System (ADS)

    KC, Utsav; Nasir, Ehson F.; Farooq, Aamir

    2015-08-01

    Acetylene is an important combustion intermediate and plays a critical role in soot formation. Accurate measurements of trace concentrations of acetylene can be very useful in validating hydrocarbon oxidation and soot formation mechanisms. Strongest vibrational band of acetylene near 13.7 μm is probed here to develop a highly sensitive absorption diagnostic. Experiments are carried out behind reflected shock waves to measure absorption cross sections of acetylene near 730 cm-1 over a wide range of temperatures (1000-2200 K) and pressures (1-5 bar). The diagnostic is demonstrated by measuring acetylene formation during the shock-heated pyrolysis and oxidation of propene.

  13. Surgical procedures for voice restoration

    PubMed Central

    Nawka, Tadeus; Hosemann, Werner

    2005-01-01

    Surgical procedures for voice restoration serve to improve oral communication by better vocal function. They comprise of phonomicrosurgery, with direct and indirect access to the larynx; laryngoplasty; laryngeal injections; and surgical laryngeal reinnervation. The basis for modern surgical techniques for voice disorders is the knowledge about the ultrastructure of the vocal folds and the increasing experience of surgeons in voice surgery, while facing high social and professional demands on the voice. Vocal activity limitation and participation restriction has become more important in the artistic and social areas. A number of surgical methods that have been developed worldwide for this reason, are presented in this article. Functional oriented surgery has to meet high standards. The diagnostics of vocal function has to be multi-dimensional in order to determine the indication and the appropriate surgical intervention. PMID:22073062

  14. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  15. Diagnostic Care: Grade 9. Technology Learning Activity. Teacher Edition. Level 2. Technology Education Series.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This Technology Learning Activity (TLA) on exploring diagnostic care careers for Grade 9 is designed for use in eight class periods. It gives students experience in using standard health care equipment to perform basic diagnostic procedures. This teacher's edition begins with an overview of technology education. The second section describes…

  16. Patient radiation exposure in diagnostic radiology examinations: an overview. Summary report

    SciTech Connect

    Burkhart, R.L.

    1983-08-01

    The report surveys the published data on entrance skin exposure received by patients during diagnostic radiology examinations. It provides a reference source to aid radiology facilities in determining whether the amount of exposure received by their patients is appropriate for the diagnostic procedures employed.

  17. Diagnostic imaging of the diabetic foot. What the clinician expects to know from the radiologist....

    PubMed

    Canadè, Adolfo; Savino, Giancarlo; Porcelli, Alessandra; Troia, Antonio; Cina, Alessandro; Pedicelli, Alessandro; Campioni, Paolo

    2003-01-01

    A case of diabetic foot in a patient with advanced diabetes is presented. The correct diagnostic approach was analyzed based on the reasoned combination of available diagnostic imaging procedures (color-Doppler US, CT-angiography, MR-angiography and digital subtraction angiography) and on the clinician's instances. Angiographic findings contraindicated intravascular treatment. Femorotibial surgical bypass was performed. PMID:15152547

  18. Diagnostic imaging in pediatric renal inflammatory disease

    SciTech Connect

    Sty, J.R.; Wells, R.G.; Schroeder, B.A.; Starshak, R.J.

    1986-08-15

    Some form of imaging procedure should be used to document the presence of infection of the upper urinary tract in troublesome cases in children. During the past several years, sonography, nuclear radiology, and computed tomography (CT) have had a significant influence on renal imaging. The purpose of this article is to reevaluate the noninvasive imaging procedures that can be used to diagnose pediatric renal inflammatory disease and to assess the relative value of each modality in the various types of renal infection. The authors will not discuss the radiologic evaluation of the child who has had a previous renal infection, in whom cortical scarring or reflux nephropathy is a possibility; these are different clinical problems and require different diagnostic evaluation.

  19. Accurate Fission Data for Nuclear Safety

    NASA Astrophysics Data System (ADS)

    Solders, A.; Gorelov, D.; Jokinen, A.; Kolhinen, V. S.; Lantz, M.; Mattera, A.; Penttilä, H.; Pomp, S.; Rakopoulos, V.; Rinta-Antila, S.

    2014-05-01

    The Accurate fission data for nuclear safety (AlFONS) project aims at high precision measurements of fission yields, using the renewed IGISOL mass separator facility in combination with a new high current light ion cyclotron at the University of Jyväskylä. The 30 MeV proton beam will be used to create fast and thermal neutron spectra for the study of neutron induced fission yields. Thanks to a series of mass separating elements, culminating with the JYFLTRAP Penning trap, it is possible to achieve a mass resolving power in the order of a few hundred thousands. In this paper we present the experimental setup and the design of a neutron converter target for IGISOL. The goal is to have a flexible design. For studies of exotic nuclei far from stability a high neutron flux (1012 neutrons/s) at energies 1 - 30 MeV is desired while for reactor applications neutron spectra that resembles those of thermal and fast nuclear reactors are preferred. It is also desirable to be able to produce (semi-)monoenergetic neutrons for benchmarking and to study the energy dependence of fission yields. The scientific program is extensive and is planed to start in 2013 with a measurement of isomeric yield ratios of proton induced fission in uranium. This will be followed by studies of independent yields of thermal and fast neutron induced fission of various actinides.

  20. Fast and Provably Accurate Bilateral Filtering

    NASA Astrophysics Data System (ADS)

    Chaudhury, Kunal N.; Dabhade, Swapnil D.

    2016-06-01

    The bilateral filter is a non-linear filter that uses a range filter along with a spatial filter to perform edge-preserving smoothing of images. A direct computation of the bilateral filter requires $O(S)$ operations per pixel, where $S$ is the size of the support of the spatial filter. In this paper, we present a fast and provably accurate algorithm for approximating the bilateral filter when the range kernel is Gaussian. In particular, for box and Gaussian spatial filters, the proposed algorithm can cut down the complexity to $O(1)$ per pixel for any arbitrary $S$. The algorithm has a simple implementation involving $N+1$ spatial filterings, where $N$ is the approximation order. We give a detailed analysis of the filtering accuracy that can be achieved by the proposed approximation in relation to the target bilateral filter. This allows us to to estimate the order $N$ required to obtain a given accuracy. We also present comprehensive numerical results to demonstrate that the proposed algorithm is competitive with state-of-the-art methods in terms of speed and accuracy.