Sana, Theodore R; Roark, Joseph C; Li, Xiangdong; Waddell, Keith; Fischer, Steven M
2008-09-01
In an effort to simplify and streamline compound identification from metabolomics data generated by liquid chromatography time-of-flight mass spectrometry, we have created software for constructing Personalized Metabolite Databases with content from over 15,000 compounds pulled from the public METLIN database (http://metlin.scripps.edu/). Moreover, we have added extra functionalities to the database that (a) permit the addition of user-defined retention times as an orthogonal searchable parameter to complement accurate mass data; and (b) allow interfacing to separate software, a Molecular Formula Generator (MFG), that facilitates reliable interpretation of any database matches from the accurate mass spectral data. To test the utility of this identification strategy, we added retention times to a subset of masses in this database, representing a mixture of 78 synthetic urine standards. The synthetic mixture was analyzed and screened against this METLIN urine database, resulting in 46 accurate mass and retention time matches. Human urine samples were subsequently analyzed under the same analytical conditions and screened against this database. A total of 1387 ions were detected in human urine; 16 of these ions matched both accurate mass and retention time parameters for the 78 urine standards in the database. Another 374 had only an accurate mass match to the database, with 163 of those masses also having the highest MFG score. Furthermore, MFG calculated a formula for a further 849 ions that had no match to the database. Taken together, these results suggest that the METLIN Personal Metabolite database and MFG software offer a robust strategy for confirming the formula of database matches. In the event of no database match, it also suggests possible formulas that may be helpful in interpreting the experimental results.
Liu, Yan-Chun; Xiao, Sa; Yang, Kun; Ling, Li; Sun, Zhi-Liang; Liu, Zhao-Ying
2017-06-01
This study reports an applicable analytical strategy of comprehensive identification and structure characterization of target components from Gelsemium elegans by using high-performance liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QqTOF MS) based on the use of accurate mass databases combined with MS/MS spectra. The databases created included accurate masses and elemental compositions of 204 components from Gelsemium and their structural data. The accurate MS and MS/MS spectra were acquired through data-dependent auto MS/MS mode followed by an extraction of the potential compounds from the LC-QqTOF MS raw data of the sample. The same was matched using the databases to search for targeted components in the sample. The structures for detected components were tentatively characterized by manually interpreting the accurate MS/MS spectra for the first time. A total of 57 components have been successfully detected and structurally characterized from the crude extracts of G. elegans, but has failed to differentiate some isomers. This analytical strategy is generic and efficient, avoids isolation and purification procedures, enables a comprehensive structure characterization of target components of Gelsemium and would be widely applicable for complicated mixtures that are derived from Gelsemium preparations. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Liao, Wenta; Draper, William M
2013-02-21
The mass-to-structure or MTS Search Engine is an Access 2010 database containing theoretical molecular mass information for 19,438 compounds assembled from common sources such as the Merck Index, pesticide and pharmaceutical compilations, and chemical catalogues. This database, which contains no experimental mass spectral data, was developed as an aid to identification of compounds in atmospheric pressure ionization (API)-LC-MS. This paper describes a powerful upgrade to this database, a fully integrated utility for filtering or ranking candidates based on isotope ratios and patterns. The new MTS Search Engine is applied here to the identification of volatile and semivolatile compounds including pesticides, nitrosoamines and other pollutants. Methane and isobutane chemical ionization (CI) GC-MS spectra were obtained from unit mass resolution mass spectrometers to determine MH(+) masses and isotope ratios. Isotopes were measured accurately with errors of <4% and <6%, respectively, for A + 1 and A + 2 peaks. Deconvolution of interfering isotope clusters (e.g., M(+) and [M - H](+)) was required for accurate determination of the A + 1 isotope in halogenated compounds. Integrating the isotope data greatly improved the speed and accuracy of the database identifications. The database accurately identified unknowns from isobutane CI spectra in 100% of cases where as many as 40 candidates satisfied the mass tolerance. The paper describes the development and basic operation of the new MTS Search Engine and details performance testing with over 50 model compounds.
Building phytochemical mass spec identification protocols and database libraries
USDA-ARS?s Scientific Manuscript database
An optimized single LC-MS evaluation that would accurately determine the elemental composition of as many compounds present in an extract would greatly aid in the evaluation of plant tissues. For phytochemicals, we have used accurate mass analysis to quickly characterize the potential chemical formu...
Seng, Piseth; Drancourt, Michel; Gouriet, Frédérique; La Scola, Bernard; Fournier, Pierre-Edouard; Rolain, Jean Marc; Raoult, Didier
2009-08-15
Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry accurately identifies both selected bacteria and bacteria in select clinical situations. It has not been evaluated for routine use in the clinic. We prospectively analyzed routine MALDI-TOF mass spectrometry identification in parallel with conventional phenotypic identification of bacteria regardless of phylum or source of isolation. Discrepancies were resolved by 16S ribosomal RNA and rpoB gene sequence-based molecular identification. Colonies (4 spots per isolate directly deposited on the MALDI-TOF plate) were analyzed using an Autoflex II Bruker Daltonik mass spectrometer. Peptidic spectra were compared with the Bruker BioTyper database, version 2.0, and the identification score was noted. Delays and costs of identification were measured. Of 1660 bacterial isolates analyzed, 95.4% were correctly identified by MALDI-TOF mass spectrometry; 84.1% were identified at the species level, and 11.3% were identified at the genus level. In most cases, absence of identification (2.8% of isolates) and erroneous identification (1.7% of isolates) were due to improper database entries. Accurate MALDI-TOF mass spectrometry identification was significantly correlated with having 10 reference spectra in the database (P=.01). The mean time required for MALDI-TOF mass spectrometry identification of 1 isolate was 6 minutes for an estimated 22%-32% cost of current methods of identification. MALDI-TOF mass spectrometry is a cost-effective, accurate method for routine identification of bacterial isolates in <1 h using a database comprising > or =10 reference spectra per bacterial species and a 1.9 identification score (Brucker system). It may replace Gram staining and biochemical identification in the near future.
Application of the accurate mass and time tag approach in studies of the human blood lipidome
Ding, Jie; Sorensen, Christina M.; Jaitly, Navdeep; Jiang, Hongliang; Orton, Daniel J.; Monroe, Matthew E.; Moore, Ronald J.; Smith, Richard D.; Metz, Thomas O.
2008-01-01
We report a preliminary demonstration of the accurate mass and time (AMT) tag approach for lipidomics. Initial data-dependent LC-MS/MS analyses of human plasma, erythrocyte, and lymphocyte lipids were performed in order to identify lipid molecular species in conjunction with complementary accurate mass and isotopic distribution information. Identified lipids were used to populate initial lipid AMT tag databases containing 250 and 45 entries for those species detected in positive and negative electrospray ionization (ESI) modes, respectively. The positive ESI database was then utilized to identify human plasma, erythrocyte, and lymphocyte lipids in high-throughput LC-MS analyses based on the AMT tag approach. We were able to define the lipid profiles of human plasma, erythrocytes, and lymphocytes based on qualitative and quantitative differences in lipid abundance. PMID:18502191
Identification of "Known Unknowns" Utilizing Accurate Mass Data and ChemSpider
NASA Astrophysics Data System (ADS)
Little, James L.; Williams, Antony J.; Pshenichnov, Alexey; Tkachenko, Valery
2012-01-01
In many cases, an unknown to an investigator is actually known in the chemical literature, a reference database, or an internet resource. We refer to these types of compounds as "known unknowns." ChemSpider is a very valuable internet database of known compounds useful in the identification of these types of compounds in commercial, environmental, forensic, and natural product samples. The database contains over 26 million entries from hundreds of data sources and is provided as a free resource to the community. Accurate mass mass spectrometry data is used to query the database by either elemental composition or a monoisotopic mass. Searching by elemental composition is the preferred approach. However, it is often difficult to determine a unique elemental composition for compounds with molecular weights greater than 600 Da. In these cases, searching by the monoisotopic mass is advantageous. In either case, the search results are refined by sorting the number of references associated with each compound in descending order. This raises the most useful candidates to the top of the list for further evaluation. These approaches were shown to be successful in identifying "known unknowns" noted in our laboratory and for compounds of interest to others.
Peptide Mass Fingerprinting of Egg White Proteins
ERIC Educational Resources Information Center
Alty, Lisa T.; LaRiviere, Frederick J.
2016-01-01
Use of advanced mass spectrometry techniques in the undergraduate setting has burgeoned in the past decade. However, relatively few undergraduate experiments examine the proteomics tools of protein digestion, peptide accurate mass determination, and database searching, also known as peptide mass fingerprinting. In this experiment, biochemistry…
Meng, Xianshuang; Bai, Hua; Guo, Teng; Niu, Zengyuan; Ma, Qiang
2017-12-15
Comprehensive identification and quantitation of 100 multi-class regulated ingredients in cosmetics was achieved using ultra-high-performance liquid chromatography (UHPLC) coupled with hybrid quadrupole-Orbitrap high-resolution mass spectrometry (Q-Orbitrap HRMS). A simple, efficient, and inexpensive sample pretreatment protocol was developed using ultrasound-assisted extraction (UAE), followed by dispersive solid-phase extraction (dSPE). The cosmetic samples were analyzed by UHPLC-Q-Orbitrap HRMS under synchronous full-scan MS and data-dependent MS/MS (full-scan MS 1 /dd-MS 2 ) acquisition mode. The mass resolution was set to 70,000 FWHM (full width at half maximum) for full-scan MS 1 and 17,500 FWHM for dd-MS 2 stage with the experimentally measured mass deviations of less than 2ppm (parts per million) for quasi-molecular ions and 5ppm for characteristic fragment ions for each individual analyte. An accurate-mass database and a mass spectral library were built in house for searching the 100 target compounds. Broad screening was conducted by comparing the experimentally measured exact mass of precursor and fragment ions, retention time, isotopic pattern, and ionic ratio with the accurate-mass database and by matching the acquired MS/MS spectra against the mass spectral library. The developed methodology was evaluated and validated in terms of limits of detection (LODs), limits of quantitation (LOQs), linearity, stability, accuracy, and matrix effect. The UHPLC-Q-Orbitrap HRMS approach was applied for the analysis of 100 target illicit ingredients in 123 genuine cosmetic samples, and exhibited great potential for high-throughput, sensitive, and reliable screening of multi-class illicit compounds in cosmetics. Copyright © 2017 Elsevier B.V. All rights reserved.
FlavonoidSearch: A system for comprehensive flavonoid annotation by mass spectrometry.
Akimoto, Nayumi; Ara, Takeshi; Nakajima, Daisuke; Suda, Kunihiro; Ikeda, Chiaki; Takahashi, Shingo; Muneto, Reiko; Yamada, Manabu; Suzuki, Hideyuki; Shibata, Daisuke; Sakurai, Nozomu
2017-04-28
Currently, in mass spectrometry-based metabolomics, limited reference mass spectra are available for flavonoid identification. In the present study, a database of probable mass fragments for 6,867 known flavonoids (FsDatabase) was manually constructed based on new structure- and fragmentation-related rules using new heuristics to overcome flavonoid complexity. We developed the FlavonoidSearch system for flavonoid annotation, which consists of the FsDatabase and a computational tool (FsTool) to automatically search the FsDatabase using the mass spectra of metabolite peaks as queries. This system showed the highest identification accuracy for the flavonoid aglycone when compared to existing tools and revealed accurate discrimination between the flavonoid aglycone and other compounds. Sixteen new flavonoids were found from parsley, and the diversity of the flavonoid aglycone among different fruits and vegetables was investigated.
Broecker, Sebastian; Herre, Sieglinde; Wüst, Bernhard; Zweigenbaum, Jerry; Pragst, Fritz
2011-04-01
A library of collision-induced dissociation (CID) accurate mass spectra has been developed for efficient use of liquid chromatography in combination with hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) as a tool in systematic toxicological analysis. The mass spectra (Δm < 3 ppm) of more than 2,500 illegal and therapeutic drugs, pesticides, alkaloids, other toxic chemicals and metabolites were measured, by use of an Agilent 6530 instrument, by flow-injection of 1 ng of the pure substances in aqueous ammonium formate-formic acid-methanol, with positive and negative electrospray-ionization (ESI), selection of the protonated or deprotonated molecules [M+H](+) or [M-H](-) by the quadrupole, and collision induced dissociation (CID) with nitrogen as collision gas at CID energies of 10, 20, and 40 eV. The fragment mass spectra were controlled for structural plausibility, corrected by recalculation to the theoretical fragment masses and added to a database of accurate mass data and molecular formulas of more than 7,500 toxicologically relevant substances to form the "database and library of toxic compounds". For practical evaluation, blood and urine samples were spiked with a mixture of 33 drugs at seven concentrations between 0.5 and 500 ng mL(-1), prepared by dichloromethane extraction or protein precipitation, and analyzed by LC-QTOF-MS in data-dependent acquisition mode. Unambiguous identification by library search was possible for typical basic drugs down to 0.5-2 ng mL(-1) and for benzodiazepines down to 2-20 ng mL(-1). The efficiency of the method was also demonstrated by re-analysis of venous blood samples from 50 death cases and comparison with previous results. In conclusion, LC-QTOF-MS in data-dependent acquisition mode combined with an accurate mass database and CID spectra library seemed to be one of the most efficient tools for systematic toxicological analysis.
Liu, Ken H; Walker, Douglas I; Uppal, Karan; Tran, ViLinh; Rohrbeck, Patricia; Mallon, Timothy M; Jones, Dean P
2016-08-01
The aim of this study was to maximize detection of serum metabolites with high-resolution metabolomics (HRM). Department of Defense Serum Repository (DoDSR) samples were analyzed using ultrahigh resolution mass spectrometry with three complementary chromatographic phases and four ionization modes. Chemical coverage was evaluated by number of ions detected and accurate mass matches to a human metabolomics database. Individual HRM platforms provided accurate mass matches for up to 58% of the KEGG metabolite database. Combining two analytical methods increased matches to 72% and included metabolites in most major human metabolic pathways and chemical classes. Detection and feature quality varied by analytical configuration. Dual chromatography HRM with positive and negative electrospray ionization provides an effective generalized method for metabolic assessment of military personnel.
Liu, Ken H.; Walker, Douglas I.; Uppal, Karan; Tran, ViLinh; Rohrbeck, Patricia; Mallon, Timothy M.; Jones, Dean P.
2016-01-01
Objective To maximize detection of serum metabolites with high-resolution metabolomics (HRM). Methods Department of Defense Serum Repository (DoDSR) samples were analyzed using ultra-high resolution mass spectrometry with three complementary chromatographic phases and four ionization modes. Chemical coverage was evaluated by number of ions detected and accurate mass matches to a human metabolomics database. Results Individual HRM platforms provided accurate mass matches for up to 58% of the KEGG metabolite database. Combining two analytical methods increased matches to 72%, and included metabolites in most major human metabolic pathways and chemical classes. Detection and feature quality varied by analytical configuration. Conclusions Dual chromatography HRM with positive and negative electrospray ionization provides an effective generalized method for metabolic assessment of military personnel. PMID:27501105
Li, Jian-Xun; Li, Xiao-Ying; Chang, Qiao-Ying; Li, Yan; Jin, Ling-He; Pang, Guo-Fang; Fan, Chun-Lin
2018-05-03
Because of its unique characteristics of accurate mass full-spectrum acquisition, high resolution, and fast acquisition rates, GC-quadrupole-time-of-flight MS (GC-Q-TOF/MS) has become a powerful tool for pesticide residue analysis. In this study, a TOF accurate mass database and Q-TOF spectrum library of 439 pesticides were established, and the parameters of the TOF database were optimized. Through solid-phase extraction (SPE), whereby pesticides are extracted from fruit and vegetable substrates by using 40 mL 1% acetic acid in acetonitrile (v/v), purified by the Carbon/NH₂ SPE cartridge, and finally detected by GC-Q-TOF/MS, the rapid analysis of 439 pesticides in fruits and vegetables can be achieved. The methodology verification results show that more than 70 and 91% of pesticides, spiked in fruits and vegetables with concentrations of 10 and 100 μg/kg, respectively, saw recoveries that conform to the European Commission's criterion of between 70 and 120% with RSD ≤20%. Eighty-one percent of pesticides have screening detection limits lower than 10 μg/kg, which makes this a reliable analysis technology for the monitoring of pesticide residues in fruits and vegetables. This technology was further validated for its characteristics of high precision, high speed, and high throughput through successful detection of 9817 samples during 2013-2015.
Agustini, Bruna Carla; Silva, Luciano Paulino; Bloch, Carlos; Bonfim, Tania M B; da Silva, Gildo Almeida
2014-06-01
Yeast identification using traditional methods which employ morphological, physiological, and biochemical characteristics can be considered a hard task as it requires experienced microbiologists and a rigorous control in culture conditions that could implicate in different outcomes. Considering clinical or industrial applications, the fast and accurate identification of microorganisms is a crescent demand. Hence, molecular biology approaches has been extensively used and, more recently, protein profiling using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has proved to be an even more efficient tool for taxonomic purposes. Nonetheless, concerning to mass spectrometry, data available for the differentiation of yeast species for industrial purpose is limited and reference databases commercially available comprise almost exclusively clinical microorganisms. In this context, studies focusing on environmental isolates are required to extend the existing databases. The development of a supplementary database and the assessment of a commercial database for taxonomic identifications of environmental yeast are the aims of this study. We challenge MALDI-TOF MS to create protein profiles for 845 yeast strains isolated from grape must and 67.7 % of the strains were successfully identified according to previously available manufacturer database. The remaining 32.3 % strains were not identified due to the absence of a reference spectrum. After matching the correct taxon for these strains by using molecular biology approaches, the spectra concerning the missing species were added in a supplementary database. This new library was able to accurately predict unidentified species at first instance by MALDI-TOF MS, proving it is a powerful tool for the identification of environmental yeasts.
Lee, Hyeyoung; Cuthbertson, Daniel J; Otter, Don E; Barile, Daniela
2016-08-17
A bovine milk oligosaccharide (BMO) library, prepared from cow colostrum, with 34 structures was generated and used to rapidly screen oligosaccharides in domestic animal milks and a whey permeate powder. The novel library was entered into a custom Personal Compound Database and Library (PCDL) and included accurate mass, retention time, and tandem mass spectra. Oligosaccharides in minute-sized samples were separated using nanoliquid chromatography (nanoLC) coupled to a high resolution and sensitive quadrupole-Time of Flight (Q-ToF) MS system. Using the PCDL, 18 oligosaccharides were found in a BMO-enriched product obtained from whey permeate processing. The usefulness of the analytical system and BMO library was further validated using milks from domestic sheep and buffaloes. Through BMO PCDL searching, 15 and 13 oligosaccharides in the BMO library were assigned in sheep and buffalo milks, respectively, thus demonstrating significant overlap between oligosaccharides in bovine (cow and buffalo) and ovine (sheep) milks. This method was shown to be an efficient, reliable, and rapid tool to identify oligosaccharide structures using automated spectral matching.
Lee, Hyeyoung; Cuthbertson, Daniel J.; Otter, Don E.; Barile, Daniela
2018-01-01
A bovine milk oligosaccharide (BMO) library, prepared from cow colostrum, with 34 structures was generated and used to rapidly screen oligosaccharides in domestic animal milks and a whey permeate powder. The novel library was entered into a custom Personal Compound Database and Library (PCDL) and included accurate mass, retention time, and tandem mass spectra. Oligosaccharides in minute-sized samples were separated using nanoliquid chromatography (nanoLC) coupled to a high resolution and sensitive quadrupole-Time of Flight (Q-ToF) MS system. Using the PCDL, 18 oligosaccharides were found in a BMO-enriched product obtained from whey permeate processing. The usefulness of the analytical system and BMO library was further validated using milks from domestic sheep and buffaloes. Through BMO PCDL searching, 15 and 13 oligosaccharides in the BMO library were assigned in sheep and buffalo milks, respectively, thus demonstrating significant overlap between oligosaccharides in bovine (cow and buffalo) and ovine (sheep) milks. This method was shown to be an efficient, reliable, and rapid tool to identify oligosaccharide structures using automated spectral matching. PMID:27428379
Rafiei, Atefeh; Sleno, Lekha
2015-01-15
Data analysis is a key step in mass spectrometry based untargeted metabolomics, starting with the generation of generic peak lists from raw liquid chromatography/mass spectrometry (LC/MS) data. Due to the use of various algorithms by different workflows, the results of different peak-picking strategies often differ widely. Raw LC/HRMS data from two types of biological samples (bile and urine), as well as a standard mixture of 84 metabolites, were processed with four peak-picking softwares: Peakview®, Markerview™, MetabolitePilot™ and XCMS Online. The overlaps between the results of each peak-generating method were then investigated. To gauge the relevance of peak lists, a database search using the METLIN online database was performed to determine which features had accurate masses matching known metabolites as well as a secondary filtering based on MS/MS spectral matching. In this study, only a small proportion of all peaks (less than 10%) were common to all four software programs. Comparison of database searching results showed peaks found uniquely by one workflow have less chance of being found in the METLIN metabolomics database and are even less likely to be confirmed by MS/MS. It was shown that the performance of peak-generating workflows has a direct impact on untargeted metabolomics results. As it was demonstrated that the peaks found in more than one peak detection workflow have higher potential to be identified by accurate mass as well as MS/MS spectrum matching, it is suggested to use the overlap of different peak-picking workflows as preliminary peak lists for more rugged statistical analysis in global metabolomics investigations. Copyright © 2014 John Wiley & Sons, Ltd.
Draper, John; Enot, David P; Parker, David; Beckmann, Manfred; Snowdon, Stuart; Lin, Wanchang; Zubair, Hassan
2009-01-01
Background Metabolomics experiments using Mass Spectrometry (MS) technology measure the mass to charge ratio (m/z) and intensity of ionised molecules in crude extracts of complex biological samples to generate high dimensional metabolite 'fingerprint' or metabolite 'profile' data. High resolution MS instruments perform routinely with a mass accuracy of < 5 ppm (parts per million) thus providing potentially a direct method for signal putative annotation using databases containing metabolite mass information. Most database interfaces support only simple queries with the default assumption that molecules either gain or lose a single proton when ionised. In reality the annotation process is confounded by the fact that many ionisation products will be not only molecular isotopes but also salt/solvent adducts and neutral loss fragments of original metabolites. This report describes an annotation strategy that will allow searching based on all potential ionisation products predicted to form during electrospray ionisation (ESI). Results Metabolite 'structures' harvested from publicly accessible databases were converted into a common format to generate a comprehensive archive in MZedDB. 'Rules' were derived from chemical information that allowed MZedDB to generate a list of adducts and neutral loss fragments putatively able to form for each structure and calculate, on the fly, the exact molecular weight of every potential ionisation product to provide targets for annotation searches based on accurate mass. We demonstrate that data matrices representing populations of ionisation products generated from different biological matrices contain a large proportion (sometimes > 50%) of molecular isotopes, salt adducts and neutral loss fragments. Correlation analysis of ESI-MS data features confirmed the predicted relationships of m/z signals. An integrated isotope enumerator in MZedDB allowed verification of exact isotopic pattern distributions to corroborate experimental data. Conclusion We conclude that although ultra-high accurate mass instruments provide major insight into the chemical diversity of biological extracts, the facile annotation of a large proportion of signals is not possible by simple, automated query of current databases using computed molecular formulae. Parameterising MZedDB to take into account predicted ionisation behaviour and the biological source of any sample improves greatly both the frequency and accuracy of potential annotation 'hits' in ESI-MS data. PMID:19622150
NASA Astrophysics Data System (ADS)
Kern, Sara E.; Lin, Lora A.; Fricke, Frederick L.
2014-08-01
U.S. food imports have been increasing steadily for decades, intensifying the need for a rapid and sensitive screening technique. A method has been developed that uses foam disks to sample the surface of incoming produce. This work provides complimentary information to the extensive amount of published pesticide fragmentation data collected using LCMS systems (Sack et al. Journal of Agricultural and Food Chemistry, 59, 6383-6411, 2011; Mol et al. Analytical and Bioanalytical Chemistry, 403, 2891-2908, 2012). The disks are directly analyzed using transmission-mode direct analysis in real time (DART) ambient pressure desorption ionization coupled to a high resolution accurate mass-mass spectrometer (HRAM-MS). In order to provide more certainty in the identification of the pesticides detected, a library of accurate mass fragments and isotopes of the protonated parent molecular ion (the [M+H]+) has been developed. The HRAM-MS is equipped with a quadrupole mass filter, providing the capability of "data-dependent" fragmentation, as opposed to "all -ion" fragmentation (where all of the ions enter a collision chamber and are fragmented at once). A temperature gradient for the DART helium stream and multiple collision energies were employed to detect and fragment 164 pesticides of varying chemical classes, sizes, and polarities. The accurate mass information of precursor ([M+H]+ ion) and fragment ions is essential in correctly identifying chemical contaminants on the surface of imported produce. Additionally, the inclusion of isotopes of the [M+H]+ in the database adds another metric to the confirmation process. The fragmentation data were collected using a Q-Exactive mass spectrometer and were added to a database used to process data collected with an Exactive mass spectrometer, an instrument that is more readily available for this screening application. The commodities investigated range from smooth-skinned produce such as apples to rougher surfaces like broccoli. The minimal sample preparation and absence of chromatography has shortened the analysis time to about 15 min per sample, and the simplicity and robustness of the technique make it ideal for rapid screening.
Critical heat flux in subcooled flow boiling
NASA Astrophysics Data System (ADS)
Hall, David Douglas
The critical heat flux (CHF) phenomenon was investigated for water flow in tubes with particular emphasis on the development of methods for predicting CHF in the subcooled flow boiling regime. The Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) CHF database for water flow in a uniformly heated tube was compiled from the world literature dating back to 1949 and represents the largest CHF database ever assembled with 32,544 data points from over 100 sources. The superiority of this database was proven via a detailed examination of previous databases. The PU-BTPFL CHF database is an invaluable tool for the development of CHF correlations and mechanistic models that are superior to existing ones developed with smaller, less comprehensive CHF databases. In response to the many inaccurate and inordinately complex correlations, two nondimensional, subcooled CHF correlations were formulated, containing only five adjustable constants and whose unique functional forms were determined without using a statistical analysis but rather using the parametric trends observed in less than 10% of the subcooled CHF data. The correlation based on inlet conditions (diameter, heated length, mass velocity, pressure, inlet quality) was by far the most accurate of all known subcooled CHF correlations, having mean absolute and root-mean-square (RMS) errors of 10.3% and 14.3%, respectively. The outlet (local) conditions correlation was the most accurate correlation based on local CHF conditions (diameter, mass velocity, pressure, outlet quality) and may be used with a nonuniform axial heat flux. Both correlations proved more accurate than a recent CHF look-up table commonly employed in nuclear reactor thermal hydraulic computer codes. An interfacial lift-off, subcooled CHF model was developed from a consideration of the instability of the vapor-liquid interface and the fraction of heat required for liquid-vapor conversion as opposed to that for bulk liquid heating. Severe vapor effusion in an upstream wetting front lifts the vapor-liquid interface off the surface, triggering CHF. Since the model is entirely based on physical observations, it has the potential to accurately predict CHF for other fluids and flow geometries which are beyond the conditions for which it was validated.
Matsuda, Fumio; Shinbo, Yoko; Oikawa, Akira; Hirai, Masami Yokota; Fiehn, Oliver; Kanaya, Shigehiko; Saito, Kazuki
2009-01-01
Background In metabolomics researches using mass spectrometry (MS), systematic searching of high-resolution mass data against compound databases is often the first step of metabolite annotation to determine elemental compositions possessing similar theoretical mass numbers. However, incorrect hits derived from errors in mass analyses will be included in the results of elemental composition searches. To assess the quality of peak annotation information, a novel methodology for false discovery rates (FDR) evaluation is presented in this study. Based on the FDR analyses, several aspects of an elemental composition search, including setting a threshold, estimating FDR, and the types of elemental composition databases most reliable for searching are discussed. Methodology/Principal Findings The FDR can be determined from one measured value (i.e., the hit rate for search queries) and four parameters determined by Monte Carlo simulation. The results indicate that relatively high FDR values (30–50%) were obtained when searching time-of-flight (TOF)/MS data using the KNApSAcK and KEGG databases. In addition, searches against large all-in-one databases (e.g., PubChem) always produced unacceptable results (FDR >70%). The estimated FDRs suggest that the quality of search results can be improved not only by performing more accurate mass analysis but also by modifying the properties of the compound database. A theoretical analysis indicates that FDR could be improved by using compound database with smaller but higher completeness entries. Conclusions/Significance High accuracy mass analysis, such as Fourier transform (FT)-MS, is needed for reliable annotation (FDR <10%). In addition, a small, customized compound database is preferable for high-quality annotation of metabolome data. PMID:19847304
Onghena, Matthias; Van Hoeck, Els; Van Loco, Joris; Ibáñez, María; Cherta, Laura; Portolés, Tania; Pitarch, Elena; Hernandéz, Félix; Lemière, Filip; Covaci, Adrian
2015-11-01
This work presents a strategy for elucidation of unknown migrants from plastic food contact materials (baby bottles) using a combination of analytical techniques in an untargeted approach. First, gas chromatography (GC) coupled to mass spectrometry (MS) in electron ionisation mode was used to identify migrants through spectral library matching. When no acceptable match was obtained, a second analysis by GC-(electron ionisation) high resolution mass spectrometry time of flight (TOF) was applied to obtain accurate mass fragmentation spectra and isotopic patterns. Databases were then searched to find a possible elemental composition for the unknown compounds. Finally, a GC hybrid quadrupole-TOF-MS with an atmospheric pressure chemical ionisation source was used to obtain the molecular ion or the protonated molecule. Accurate mass data also provided additional information on the fragmentation behaviour as two acquisition functions with different collision energies were available (MS(E) approach). In the low-energy function, limited fragmentation took place, whereas for the high-energy function, fragmentation was enhanced. For less volatile unknowns, ultra-high pressure liquid chromatography-quadrupole-TOF-MS was additionally applied. Using a home-made database containing common migrating compounds and plastic additives, tentative identification was made for several positive findings based on accurate mass of the (de)protonated molecule, product ion fragments and characteristic isotopic ions. Six illustrative examples are shown to demonstrate the modus operandi and the difficulties encountered during identification. The combination of these techniques was proven to be a powerful tool for the elucidation of unknown migrating compounds from plastic baby bottles. Copyright © 2015 John Wiley & Sons, Ltd.
Thurman, E Michael; Ferrer, Imma; Zavitsanos, Paul; Zweigenbaum, Jerry A
2013-09-15
Imidacloprid is a potent and widely used insecticide on vegetable crops, such as onion (Allium cepa L.). Because of possible toxicity to beneficial insects, imidacloprid and several metabolites have raised safety concerns for pollenating insects, such as honey bees. Thus, imidacloprid metabolites continue to be an important subject for new methods that better understand its dissipation and fate in plants, such as onions. One month after a single addition of imidacloprid to soil containing onion plants, imidacloprid and its metabolites were extracted from pulverized onion with a methanol/water-buffer mixture and analyzed by liquid chromatography/quadrupole time-of-flight mass spectrometry (LC/QTOF-MS) using a labeled imidacloprid internal standard and tandem mass spectrometric (MS/MS) analysis. Accurate mass tools were developed and applied to detect seven new metabolites of imidacloprid with the goal to better understand its fate in onion. The accurate mass tools include: database searching, diagnostic ions, chlorine mass filters, Mass Profiler software, and manual use of metabolic analogy. The new metabolites discovered included an amine reduction product (m/z 226.0854), and its methylated analogue (m/z 240.1010), and five other metabolites, all of unknown toxicity to insects. The accurate mass tools were combined with LC/QTOF-MS and were able to detect both known and new metabolites of imidacloprid using fragmentation studies of both parent and labeled standards. New metabolites and their structures were inferred from these MS/MS studies with accurate mass, which makes it possible to better understand imidacloprid metabolism in onion as well as new metabolite targets for toxicity studies. Copyright © 2013 John Wiley & Sons, Ltd.
Magnette, Amandine; Huang, Te-Din; Renzi, Francesco; Bogaerts, Pierre; Cornelis, Guy R; Glupczynski, Youri
2016-01-01
Capnocytophaga canimorsus and Capnocytophaga cynodegmi can be transmitted from dogs or cats and cause serious human infections. We aimed to evaluate the ability of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) to identify these two Capnocytophaga species. Ninety-four C. canimorsus and 10 C. cynodegmi isolates identified by 16S rRNA gene sequencing were analyzed. Using the MALDI BioTyper database, correct identification was achieved for only 16 of 94 (17%) C. canimorsus and all 10 C. cynodegmi strains, according to the manufacturer's log score specifications. Following the establishment of a complementary homemade reference database by addition of 51 C. canimorsus and 8 C. cynodegmi mass spectra, MALDI-TOF MS provided reliable identification to the species level for 100% of the 45 blind-coded Capnocytophaga isolates tested. MALDI-TOF MS can accurately identify C. canimorsus and C. cynodegmi using an enriched database and thus constitutes a valuable diagnostic tool in the clinical laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.
Sakurai, Nozomu; Ara, Takeshi; Kanaya, Shigehiko; Nakamura, Yukiko; Iijima, Yoko; Enomoto, Mitsuo; Motegi, Takeshi; Aoki, Koh; Suzuki, Hideyuki; Shibata, Daisuke
2013-01-15
High-accuracy mass values detected by high-resolution mass spectrometry analysis enable prediction of elemental compositions, and thus are used for metabolite annotations in metabolomic studies. Here, we report an application of a relational database to significantly improve the rate of elemental composition predictions. By searching a database of pre-calculated elemental compositions with fixed kinds and numbers of atoms, the approach eliminates redundant evaluations of the same formula that occur in repeated calculations with other tools. When our approach is compared with HR2, which is one of the fastest tools available, our database search times were at least 109 times shorter than those of HR2. When a solid-state drive (SSD) was applied, the search time was 488 times shorter at 5 ppm mass tolerance and 1833 times at 0.1 ppm. Even if the search by HR2 was performed with 8 threads in a high-spec Windows 7 PC, the database search times were at least 26 and 115 times shorter without and with the SSD. These improvements were enhanced in a low spec Windows XP PC. We constructed a web service 'MFSearcher' to query the database in a RESTful manner. Available for free at http://webs2.kazusa.or.jp/mfsearcher. The web service is implemented in Java, MySQL, Apache and Tomcat, with all major browsers supported. sakurai@kazusa.or.jp Supplementary data are available at Bioinformatics online.
McMullen, Allison R; Wallace, Meghan A; Pincus, David H; Wilkey, Kathy; Burnham, C A
2016-08-01
Invasive fungal infections have a high rate of morbidity and mortality, and accurate identification is necessary to guide appropriate antifungal therapy. With the increasing incidence of invasive disease attributed to filamentous fungi, rapid and accurate species-level identification of these pathogens is necessary. Traditional methods for identification of filamentous fungi can be slow and may lack resolution. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for identification of bacteria and yeasts, but a paucity of data exists on the performance characteristics of this method for identification of filamentous fungi. The objective of our study was to evaluate the accuracy of the Vitek MS for mold identification. A total of 319 mold isolates representing 43 genera recovered from clinical specimens were evaluated. Of these isolates, 213 (66.8%) were correctly identified using the Vitek MS Knowledge Base, version 3.0 database. When a modified SARAMIS (Spectral Archive and Microbial Identification System) database was used to augment the version 3.0 Knowledge Base, 245 (76.8%) isolates were correctly identified. Unidentified isolates were subcultured for repeat testing; 71/319 (22.3%) remained unidentified. Of the unidentified isolates, 69 were not in the database. Only 3 (0.9%) isolates were misidentified by MALDI-TOF MS (including Aspergillus amoenus [n = 2] and Aspergillus calidoustus [n = 1]) although 10 (3.1%) of the original phenotypic identifications were not correct. In addition, this methodology was able to accurately identify 133/144 (93.6%) Aspergillus sp. isolates to the species level. MALDI-TOF MS has the potential to expedite mold identification, and misidentifications are rare. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Ojima-Kato, Teruyo; Yamamoto, Naomi; Nagai, Satomi; Shima, Keisuke; Akiyama, Yumi; Ota, Junji; Tamura, Hiroto
2017-12-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based microbial identification is a popular analytical method. Strain Solution proteotyping software available for MALDI-TOF MS has great potential for the precise and detailed discrimination of microorganisms at serotype- or strain-level, beyond the conventional mass fingerprinting approaches. Here, we constructed a theoretically calculated mass database of Salmonella enterica subspecies enterica consisting of 12 biomarker proteins: ribosomal proteins S8, L15, L17, L21, L25, and S7, Mn-cofactor-containing superoxide dismutase (SodA), peptidyl-prolyl cis-trans isomerase C (PPIase C), and protein Gns, and uncharacterized proteins YibT, YaiA, and YciF, that can allow serotyping of Salmonella. Strain Solution ver. 2 software with the novel database constructed in this study demonstrated that 109 strains (94%), including the major outbreak-associated serotypes, Enteritidis, Typhimurium, and Infantis, could be correctly identified from others by colony-directed MALDI-TOF MS using 116 strains belonging to 23 kinds of typed and untyped serotypes of S. enterica from culture collections, patients, and foods. We conclude that Strain Solution ver. 2 software integrated with the accurate mass database will be useful for the bacterial proteotyping by MALDI-TOF MS-based microbial classification in the clinical and food safety fields.
Månsson, Viktor; Gilsdorf, Janet R; Kahlmeter, Gunnar; Kilian, Mogens; Kroll, J Simon; Riesbeck, Kristian; Resman, Fredrik
2018-03-01
Encapsulated Haemophilus influenzae strains belong to type-specific genetic lineages. Reliable capsule typing requires PCR, but a more efficient method would be useful. We evaluated capsule typing by using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Isolates of all capsule types (a-f and nontypeable; n = 258) and isogenic capsule transformants (types a-d) were investigated. Principal component and biomarker analyses of mass spectra showed clustering, and mass peaks correlated with capsule type-specific genetic lineages. We used 31 selected isolates to construct a capsule typing database. Validation with the remaining isolates (n = 227) showed 100% sensitivity and 92.2% specificity for encapsulated strains (a-f; n = 61). Blinded validation of a supplemented database (n = 50) using clinical isolates (n = 126) showed 100% sensitivity and 100% specificity for encapsulated strains (b, e, and f; n = 28). MALDI-TOF mass spectrometry is an accurate method for capsule typing of H. influenzae.
Tsanas, Athanasios; Clifford, Gari D
2015-01-01
Sleep spindles are critical in characterizing sleep and have been associated with cognitive function and pathophysiological assessment. Typically, their detection relies on the subjective and time-consuming visual examination of electroencephalogram (EEG) signal(s) by experts, and has led to large inter-rater variability as a result of poor definition of sleep spindle characteristics. Hitherto, many algorithmic spindle detectors inherently make signal stationarity assumptions (e.g., Fourier transform-based approaches) which are inappropriate for EEG signals, and frequently rely on additional information which may not be readily available in many practical settings (e.g., more than one EEG channels, or prior hypnogram assessment). This study proposes a novel signal processing methodology relying solely on a single EEG channel, and provides objective, accurate means toward probabilistically assessing the presence of sleep spindles in EEG signals. We use the intuitively appealing continuous wavelet transform (CWT) with a Morlet basis function, identifying regions of interest where the power of the CWT coefficients corresponding to the frequencies of spindles (11-16 Hz) is large. The potential for assessing the signal segment as a spindle is refined using local weighted smoothing techniques. We evaluate our findings on two databases: the MASS database comprising 19 healthy controls and the DREAMS sleep spindle database comprising eight participants diagnosed with various sleep pathologies. We demonstrate that we can replicate the experts' sleep spindles assessment accurately in both databases (MASS database: sensitivity: 84%, specificity: 90%, false discovery rate 83%, DREAMS database: sensitivity: 76%, specificity: 92%, false discovery rate: 67%), outperforming six competing automatic sleep spindle detection algorithms in terms of correctly replicating the experts' assessment of detected spindles.
Gugiu, Gabriel B
2017-01-01
Lipidomics refers to the large-scale study of lipids in biological systems (Wenk, Nat Rev Drug Discov 4(7):594-610, 2005; Rolim et al., Gene 554(2):131-139, 2015). From a mass spectrometric point of view, by lipidomics we understand targeted or untargeted mass spectrometric analysis of lipids using either liquid chromatography (LC) (Castro-Perez et al., J Proteome Res 9(5):2377-2389, 2010) or shotgun (Han and Gross, Mass Spectrom Rev 24(3):367-412, 2005) approaches coupled with tandem mass spectrometry. This chapter describes the former methodology, which is becoming rapidly the preferred method for lipid identification owing to similarities with established omics workflows, such as proteomics (Washburn et al., Nat Biotechnol 19(3):242-247, 2001) or genomics (Yadav, J Biomol Tech: JBT 18(5):277, 2007). The workflow described consists in lipid extraction using a modified Bligh and Dyer method (Bligh and Dyer, Can J Biochem Physiol 37(8):911-917, 1959), ultra high pressure liquid chromatography fractionation of lipid samples on a reverse phase C18 column, followed by tandem mass spectrometric analysis and in silico database search for lipid identification based on MSMS spectrum matching (Kind et al., Nat Methods 10(8):755-758, 2013; Yamada et al., J Chromatogr A 1292:211-218, 2013; Taguchi and Ishikawa, J Chromatogr A 1217(25):4229-4239, 2010; Peake et al., Thermoscientifices 1-3, 2015) and accurate mass of parent ion (Sud et al., Nucleic Acids Res 35(database issue):D527-D532, 2007; Wishart et al., Nucleic Acids Res 35(database):D521-D526, 2007).
Zhao, Xinjie; Zeng, Zhongda; Chen, Aiming; Lu, Xin; Zhao, Chunxia; Hu, Chunxiu; Zhou, Lina; Liu, Xinyu; Wang, Xiaolin; Hou, Xiaoli; Ye, Yaorui; Xu, Guowang
2018-05-29
Identification of the metabolites is an essential step in metabolomics study to interpret regulatory mechanism of pathological and physiological processes. However, it is still a big headache in LC-MSn-based studies because of the complexity of mass spectrometry, chemical diversity of metabolites, and deficiency of standards database. In this work, a comprehensive strategy is developed for accurate and batch metabolite identification in non-targeted metabolomics studies. First, a well defined procedure was applied to generate reliable and standard LC-MS2 data including tR, MS1 and MS2 information at a standard operational procedure (SOP). An in-house database including about 2000 metabolites was constructed and used to identify the metabolites in non-targeted metabolic profiling by retention time calibration using internal standards, precursor ion alignment and ion fusion, auto-MS2 information extraction and selection, and database batch searching and scoring. As an application example, a pooled serum sample was analyzed to deliver the strategy, 202 metabolites were identified in the positive ion mode. It shows our strategy is useful for LC-MSn-based non-targeted metabolomics study.
Pang, Guo-Fang; Fan, Chun-Lin; Chang, Qiao-Ying; Li, Jian-Xun; Kang, Jian; Lu, Mei-Ling
2018-03-22
This paper uses the LC-quadrupole-time-of-flight MS technique to evaluate the behavioral characteristics of MSof 485 pesticides under different conditions and has developed an accurate mass database and spectra library. A high-throughput screening and confirmation method has been developed for the 485 pesticides in fruits and vegetables. Through the optimization of parameters such as accurate mass number, time of retention window, ionization forms, etc., the method has improved the accuracy of pesticide screening, thus avoiding the occurrence of false-positive and false-negative results. The method features a full scan of fragments, with 80% of pesticide qualitative points over 10, which helps increase pesticide qualitative accuracy. The abundant differences of fragment categories help realize the effective separation and qualitative identification of isomer pesticides. Four different fruits and vegetables-apples, grapes, celery, and tomatoes-were chosen to evaluate the efficiency of the method at three fortification levels of 5, 10, and 20 μg/kg, and satisfactory results were obtained. With this method, a national survey of pesticide residues was conducted between 2012 and 2015 for 12 551 samples of 146 different fruits and vegetables collected from 638 sampling points in 284 counties across 31 provincial capitals/cities directly under the central government, which provided scientific data backup for ensuring pesticide residue safety of the fruits and vegetables consumed daily by the public. Meanwhile, the big data statistical analysis of the new technique also further proves it to be of high speed, high throughput, high accuracy, high reliability, and high informatization.
Stanley, Jeffrey R.; Adkins, Joshua N.; Slysz, Gordon W.; Monroe, Matthew E.; Purvine, Samuel O.; Karpievitch, Yuliya V.; Anderson, Gordon A.; Smith, Richard D.; Dabney, Alan R.
2011-01-01
Current algorithms for quantifying peptide identification confidence in the accurate mass and time (AMT) tag approach assume that the AMT tags themselves have been correctly identified. However, there is uncertainty in the identification of AMT tags, as this is based on matching LC-MS/MS fragmentation spectra to peptide sequences. In this paper, we incorporate confidence measures for the AMT tag identifications into the calculation of probabilities for correct matches to an AMT tag database, resulting in a more accurate overall measure of identification confidence for the AMT tag approach. The method is referred to as Statistical Tools for AMT tag Confidence (STAC). STAC additionally provides a Uniqueness Probability (UP) to help distinguish between multiple matches to an AMT tag and a method to calculate an overall false discovery rate (FDR). STAC is freely available for download as both a command line and a Windows graphical application. PMID:21692516
Thurman, E Michael; Ferrer, Imma; Blotevogel, Jens; Borch, Thomas
2014-10-07
Two series of ethylene oxide (EO) surfactants, polyethylene glycols (PEGs from EO3 to EO33) and linear alkyl ethoxylates (LAEs C-9 to C-15 with EO3-EO28), were identified in hydraulic fracturing flowback and produced water using a new application of the Kendrick mass defect and liquid chromatography/quadrupole-time-of-flight mass spectrometry. The Kendrick mass defect differentiates the proton, ammonium, and sodium adducts in both singly and doubly charged forms. A structural model of adduct formation is presented, and binding constants are calculated, which is based on a spherical cagelike conformation, where the central cation (NH4(+) or Na(+)) is coordinated with ether oxygens. A major purpose of the study was the identification of the ethylene oxide (EO) surfactants and the construction of a database with accurate masses and retention times in order to unravel the mass spectral complexity of surfactant mixtures used in hydraulic fracturing fluids. For example, over 500 accurate mass assignments are made in a few seconds of computer time, which then is used as a fingerprint chromatogram of the water samples. This technique is applied to a series of flowback and produced water samples to illustrate the usefulness of ethoxylate "fingerprinting", in a first application to monitor water quality that results from fluids used in hydraulic fracturing.
Wang, Jian; Chow, Willis; Chang, James; Wong, Jon W
2017-01-18
A semiautomated qualitative method for target screening of 448 pesticide residues in fruits and vegetables was developed and validated using ultrahigh-performance liquid chromatography coupled with electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap). The Q-Orbitrap Full MS/dd-MS 2 (data dependent acquisition) was used to acquire product-ion spectra of individual pesticides to build a compound database or an MS library, while its Full MS/DIA (data independent acquisition) was utilized for sample data acquisition from fruit and vegetable matrices fortified with pesticides at 10 and 100 μg/kg for target screening purpose. Accurate mass, retention time and response threshold were three key parameters in a compound database that were used to detect incurred pesticide residues in samples. The concepts and practical aspects of in-spectrum mass correction or solvent background lock-mass correction, retention time alignment and response threshold adjustment are discussed while building a functional and working compound database for target screening. The validated target screening method is capable of screening at least 94% and 99% of 448 pesticides at 10 and 100 μg/kg, respectively, in fruits and vegetables without having to evaluate every compound manually during data processing, which significantly reduced the workload in routine practice.
Hjelmeland, Anna K; Zweigenbaum, Jerry; Ebeler, Susan E
2015-08-05
In this work we present a novel approach for the identification of plant metabolites using ultrahigh performance liquid chromatography coupled to accurate mass time-of-flight mass spectrometry. The workflow involves developing an in-house compound database consisting of exact masses of previously identified as well as putative compounds. The database is used to screen accurate mass spectrometry (MS) data to identify possible compound matches. Subsequent tandem MS data is acquired for possible matches and used for structural elucidation. The methodology is applied to profile monoterpene glycosides in Vitis vinifera cv. Muscat of Alexandria grape berries over three developmental stages. Monoterpenes are a subclass of terpenes, the largest class of plant secondary metabolites, and are found in two major forms in the plant, "bound" to one or more sugar moieties or "free" of said sugar moieties. In the free form, monoterpenes are noted for their fragrance and play important roles in plant defense and as attractants for pollinators. However, glycoconjugation renders these compounds odorless, and it is this form that the plant uses for monoterpene storage. In order to gain insight into monoterpene biochemistry and their fate in the plant an analysis of intact glycosides is essential. Eighteen monoterpene glycosides were identified including a monoterpene trisaccharide glycoside, which is tentatively identified here for this first time in any plant. Additionally, while previous studies have identified monoterpene malonylated glucosides in other grapevine tissue, we tentatively identify them for the first time in grape berries. This analytical approach can be readily applied to other plants and the workflow approach can also be used for other classes of compounds. This approach, in general, provides researchers with data to support the identification of putative compounds, which is especially useful when no standard is available. Copyright © 2015 Elsevier B.V. All rights reserved.
MASSCLEANage—Stellar Cluster Ages from Integrated Colors
NASA Astrophysics Data System (ADS)
Popescu, Bogdan; Hanson, M. M.
2010-11-01
We present the recently updated and expanded MASSCLEANcolors, a database of 70 million Monte Carlo models selected to match the properties (metallicity, ages, and masses) of stellar clusters found in the Large Magellanic Cloud (LMC). This database shows the rather extreme and non-Gaussian distribution of integrated colors and magnitudes expected with different cluster age and mass and the enormous age degeneracy of integrated colors when mass is unknown. This degeneracy could lead to catastrophic failures in estimating age with standard simple stellar population models, particularly if most of the clusters are of intermediate or low mass, like in the LMC. Utilizing the MASSCLEANcolors database, we have developed MASSCLEANage, a statistical inference package which assigns the most likely age and mass (solved simultaneously) to a cluster based only on its integrated broadband photometric properties. Finally, we use MASSCLEANage to derive the age and mass of LMC clusters based on integrated photometry alone. First, we compare our cluster ages against those obtained for the same seven clusters using more accurate integrated spectroscopy. We find improved agreement with the integrated spectroscopy ages over the original photometric ages. A close examination of our results demonstrates the necessity of solving simultaneously for mass and age to reduce degeneracies in the cluster ages derived via integrated colors. We then selected an additional subset of 30 photometric clusters with previously well-constrained ages and independently derive their age using the MASSCLEANage with the same photometry with very good agreement. The MASSCLEANage program is freely available under GNU General Public License.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb-Robertson, Bobbie-Jo M.
Accurate identification of peptides is a current challenge in mass spectrometry (MS) based proteomics. The standard approach uses a search routine to compare tandem mass spectra to a database of peptides associated with the target organism. These database search routines yield multiple metrics associated with the quality of the mapping of the experimental spectrum to the theoretical spectrum of a peptide. The structure of these results make separating correct from false identifications difficult and has created a false identification problem. Statistical confidence scores are an approach to battle this false positive problem that has led to significant improvements in peptidemore » identification. We have shown that machine learning, specifically support vector machine (SVM), is an effective approach to separating true peptide identifications from false ones. The SVM-based peptide statistical scoring method transforms a peptide into a vector representation based on database search metrics to train and validate the SVM. In practice, following the database search routine, a peptides is denoted in its vector representation and the SVM generates a single statistical score that is then used to classify presence or absence in the sample« less
Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang
2016-09-06
Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madar, Inamul Hasan; Ko, Seung-Ik; Kim, Hokeun
Mass spectrometry (MS)-based proteomics, which uses high-resolution hybrid mass spectrometers such as the quadrupole-orbitrap mass spectrometer, can yield tens of thousands of tandem mass (MS/MS) spectra of high resolution during a routine bottom-up experiment. Despite being a fundamental and key step in MS-based proteomics, the accurate determination and assignment of precursor monoisotopic masses to the MS/MS spectra remains difficult. The difficulties stem from imperfect isotopic envelopes of precursor ions, inaccurate charge states for precursor ions, and cofragmentation. We describe a composite method of utilizing MS data to assign accurate monoisotopic masses to MS/MS spectra, including those subject to cofragmentation. Themore » method, “multiplexed post-experiment monoisotopic mass refinement” (mPE-MMR), consists of the following: multiplexing of precursor masses to assign multiple monoisotopic masses of cofragmented peptides to the corresponding multiplexed MS/MS spectra, multiplexing of charge states to assign correct charges to the precursor ions of MS/ MS spectra with no charge information, and mass correction for inaccurate monoisotopic peak picking. When combined with MS-GF+, a database search algorithm based on fragment mass difference, mPE-MMR effectively increases both sensitivity and accuracy in peptide identification from complex high-throughput proteomics data compared to conventional methods.« less
Mathis, Alexander; Depaquit, Jérôme; Dvořák, Vit; Tuten, Holly; Bañuls, Anne-Laure; Halada, Petr; Zapata, Sonia; Lehrter, Véronique; Hlavačková, Kristýna; Prudhomme, Jorian; Volf, Petr; Sereno, Denis; Kaufmann, Christian; Pflüger, Valentin; Schaffner, Francis
2015-05-10
Rapid, accurate and high-throughput identification of vector arthropods is of paramount importance in surveillance programmes that are becoming more common due to the changing geographic occurrence and extent of many arthropod-borne diseases. Protein profiling by MALDI-TOF mass spectrometry fulfils these requirements for identification, and reference databases have recently been established for several vector taxa, mostly with specimens from laboratory colonies. We established and validated a reference database containing 20 phlebotomine sand fly (Diptera: Psychodidae, Phlebotominae) species by using specimens from colonies or field-collections that had been stored for various periods of time. Identical biomarker mass patterns ('superspectra') were obtained with colony- or field-derived specimens of the same species. In the validation study, high quality spectra (i.e. more than 30 evaluable masses) were obtained with all fresh insects from colonies, and with 55/59 insects deep-frozen (liquid nitrogen/-80 °C) for up to 25 years. In contrast, only 36/52 specimens stored in ethanol could be identified. This resulted in an overall sensitivity of 87 % (140/161); specificity was 100 %. Duration of storage impaired data counts in the high mass range, and thus cluster analyses of closely related specimens might reflect their storage conditions rather than phenotypic distinctness. A major drawback of MALDI-TOF MS is the restricted availability of in-house databases and the fact that mass spectrometers from 2 companies (Bruker, Shimadzu) are widely being used. We have analysed fingerprints of phlebotomine sand flies obtained by automatic routine procedure on a Bruker instrument by using our database and the software established on a Shimadzu system. The sensitivity with 312 specimens from 8 sand fly species from laboratory colonies when evaluating only high quality spectra was 98.3 %; the specificity was 100 %. The corresponding diagnostic values with 55 field-collected specimens from 4 species were 94.7 % and 97.4 %, respectively. A centralized high-quality database (created by expert taxonomists and experienced users of mass spectrometers) that is easily amenable to customer-oriented identification services is a highly desirable resource. As shown in the present work, spectra obtained from different specimens with different instruments can be analysed using a centralized database, which should be available in the near future via an online platform in a cost-efficient manner.
Das, Arpita; Bhattacharya, Mahua
2011-01-01
In the present work, authors have developed a treatment planning system implementing genetic based neuro-fuzzy approaches for accurate analysis of shape and margin of tumor masses appearing in breast using digital mammogram. It is obvious that a complicated structure invites the problem of over learning and misclassification. In proposed methodology, genetic algorithm (GA) has been used for searching of effective input feature vectors combined with adaptive neuro-fuzzy model for final classification of different boundaries of tumor masses. The study involves 200 digitized mammograms from MIAS and other databases and has shown 86% correct classification rate.
MASSCLEANage-STELLAR CLUSTER AGES FROM INTEGRATED COLORS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popescu, Bogdan; Hanson, M. M., E-mail: popescb@mail.uc.ed, E-mail: margaret.hanson@uc.ed
2010-11-20
We present the recently updated and expanded MASSCLEANcolors, a database of 70 million Monte Carlo models selected to match the properties (metallicity, ages, and masses) of stellar clusters found in the Large Magellanic Cloud (LMC). This database shows the rather extreme and non-Gaussian distribution of integrated colors and magnitudes expected with different cluster age and mass and the enormous age degeneracy of integrated colors when mass is unknown. This degeneracy could lead to catastrophic failures in estimating age with standard simple stellar population models, particularly if most of the clusters are of intermediate or low mass, like in the LMC.more » Utilizing the MASSCLEANcolors database, we have developed MASSCLEANage, a statistical inference package which assigns the most likely age and mass (solved simultaneously) to a cluster based only on its integrated broadband photometric properties. Finally, we use MASSCLEANage to derive the age and mass of LMC clusters based on integrated photometry alone. First, we compare our cluster ages against those obtained for the same seven clusters using more accurate integrated spectroscopy. We find improved agreement with the integrated spectroscopy ages over the original photometric ages. A close examination of our results demonstrates the necessity of solving simultaneously for mass and age to reduce degeneracies in the cluster ages derived via integrated colors. We then selected an additional subset of 30 photometric clusters with previously well-constrained ages and independently derive their age using the MASSCLEANage with the same photometry with very good agreement. The MASSCLEANage program is freely available under GNU General Public License.« less
NASA Technical Reports Server (NTRS)
Morelli, E. A.; Proffitt, M. S.
1999-01-01
The data for longitudinal non-dimensional, aerodynamic coefficients in the High Speed Research Cycle 2B aerodynamic database were modeled using polynomial expressions identified with an orthogonal function modeling technique. The discrepancy between the tabular aerodynamic data and the polynomial models was tested and shown to be less than 15 percent for drag, lift, and pitching moment coefficients over the entire flight envelope. Most of this discrepancy was traced to smoothing local measurement noise and to the omission of mass case 5 data in the modeling process. A simulation check case showed that the polynomial models provided a compact and accurate representation of the nonlinear aerodynamic dependencies contained in the HSR Cycle 2B tabular aerodynamic database.
Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael
2018-04-20
The suitability of dispersive liquid-liquid microextraction (DLLME) and gas chromatography accurate mass spectrometry (GC-MS), based on a time-of-flight (TOF) MS analyzer and using electron ionization (EI), for the characterization of volatile and semi-volatile profiles of grape marc distillates (grappa) are evaluated. DLLME conditions are optimized with a selection of compounds, from different chemical families, present in the distillate spirit. Under final working conditions, 2.5 mL of sample and 0.5 mL of organic solvents are consumed in the sample preparation process. The absolute extraction efficiencies ranged from 30 to 100%, depending on the compound. For the same sample volume, DLLME provided higher responses than solid-phase microextraction (SPME) for most of the model compounds. The GC-EI-TOF-MS records of grappa samples were processed using a data mining non-targeted search algorithm. In this way, chromatographic peaks and accurate EI-MS spectra of sample components were linked. The identities of more than 140 of these components are proposed from comparison of their accurate spectra with those in a low resolution EI-MS database, accurate masses of most intense fragment ions of known structure, and available chromatographic retention index. The use of chromatographic and spectral data, associated to the set of components mined from different grappa samples, for multivariate analysis purposes is also illustrated in the study. Copyright © 2018 Elsevier B.V. All rights reserved.
A new, high-resolution global mass coral bleaching database
Rickbeil, Gregory J. M.; Heron, Scott F.
2017-01-01
Episodes of mass coral bleaching have been reported in recent decades and have raised concerns about the future of coral reefs on a warming planet. Despite the efforts to enhance and coordinate coral reef monitoring within and across countries, our knowledge of the geographic extent of mass coral bleaching over the past few decades is incomplete. Existing databases, like ReefBase, are limited by the voluntary nature of contributions, geographical biases in data collection, and the variations in the spatial scale of bleaching reports. In this study, we have developed the first-ever gridded, global-scale historical coral bleaching database. First, we conducted a targeted search for bleaching reports not included in ReefBase by personally contacting scientists and divers conducting monitoring in under-reported locations and by extracting data from the literature. This search increased the number of observed bleaching reports by 79%, from 4146 to 7429. Second, we employed spatial interpolation techniques to develop annual 0.04° × 0.04° latitude-longitude global maps of the probability that bleaching occurred for 1985 through 2010. Initial results indicate that the area of coral reefs with a more likely than not (>50%) or likely (>66%) probability of bleaching was eight times higher in the second half of the assessed time period, after the 1997/1998 El Niño. The results also indicate that annual maximum Degree Heating Weeks, a measure of thermal stress, for coral reefs with a high probability of bleaching increased over time. The database will help the scientific community more accurately assess the change in the frequency of mass coral bleaching events, validate methods of predicting mass coral bleaching, and test whether coral reefs are adjusting to rising ocean temperatures. PMID:28445534
A new, high-resolution global mass coral bleaching database.
Donner, Simon D; Rickbeil, Gregory J M; Heron, Scott F
2017-01-01
Episodes of mass coral bleaching have been reported in recent decades and have raised concerns about the future of coral reefs on a warming planet. Despite the efforts to enhance and coordinate coral reef monitoring within and across countries, our knowledge of the geographic extent of mass coral bleaching over the past few decades is incomplete. Existing databases, like ReefBase, are limited by the voluntary nature of contributions, geographical biases in data collection, and the variations in the spatial scale of bleaching reports. In this study, we have developed the first-ever gridded, global-scale historical coral bleaching database. First, we conducted a targeted search for bleaching reports not included in ReefBase by personally contacting scientists and divers conducting monitoring in under-reported locations and by extracting data from the literature. This search increased the number of observed bleaching reports by 79%, from 4146 to 7429. Second, we employed spatial interpolation techniques to develop annual 0.04° × 0.04° latitude-longitude global maps of the probability that bleaching occurred for 1985 through 2010. Initial results indicate that the area of coral reefs with a more likely than not (>50%) or likely (>66%) probability of bleaching was eight times higher in the second half of the assessed time period, after the 1997/1998 El Niño. The results also indicate that annual maximum Degree Heating Weeks, a measure of thermal stress, for coral reefs with a high probability of bleaching increased over time. The database will help the scientific community more accurately assess the change in the frequency of mass coral bleaching events, validate methods of predicting mass coral bleaching, and test whether coral reefs are adjusting to rising ocean temperatures.
1988-06-01
DETAILED PROBLEM STATEM ENT ......................................................... 23 A . INTRODUCTION...assorted information about the world land masses. When this is done, the problem of storage, manipulation, and display of realistic, dense, and accurate...elevation data becomes a problem of paramount importance. If the data which is stored can be utilized to recreate specific information about certain
Jeffryes, James G.; Colastani, Ricardo L.; Elbadawi-Sidhu, Mona; ...
2015-08-28
Metabolomics have proven difficult to execute in an untargeted and generalizable manner. Liquid chromatography–mass spectrometry (LC–MS) has made it possible to gather data on thousands of cellular metabolites. However, matching metabolites to their spectral features continues to be a bottleneck, meaning that much of the collected information remains uninterpreted and that new metabolites are seldom discovered in untargeted studies. These challenges require new approaches that consider compounds beyond those available in curated biochemistry databases. Here we present Metabolic In silico Network Expansions (MINEs), an extension of known metabolite databases to include molecules that have not been observed, but are likelymore » to occur based on known metabolites and common biochemical reactions. We utilize an algorithm called the Biochemical Network Integrated Computational Explorer (BNICE) and expert-curated reaction rules based on the Enzyme Commission classification system to propose the novel chemical structures and reactions that comprise MINE databases. Starting from the Kyoto Encyclopedia of Genes and Genomes (KEGG) COMPOUND database, the MINE contains over 571,000 compounds, of which 93% are not present in the PubChem database. However, these MINE compounds have on average higher structural similarity to natural products than compounds from KEGG or PubChem. MINE databases were able to propose annotations for 98.6% of a set of 667 MassBank spectra, 14% more than KEGG alone and equivalent to PubChem while returning far fewer candidates per spectra than PubChem (46 vs. 1715 median candidates). Application of MINEs to LC–MS accurate mass data enabled the identity of an unknown peak to be confidently predicted. MINE databases are freely accessible for non-commercial use via user-friendly web-tools at http://minedatabase.mcs.anl.gov and developer-friendly APIs. MINEs improve metabolomics peak identification as compared to general chemical databases whose results include irrelevant synthetic compounds. MINEs complement and expand on previous in silico generated compound databases that focus on human metabolism. We are actively developing the database; future versions of this resource will incorporate transformation rules for spontaneous chemical reactions and more advanced filtering and prioritization of candidate structures.« less
Detection of alternative splice variants at the proteome level in Aspergillus flavus.
Chang, Kung-Yen; Georgianna, D Ryan; Heber, Steffen; Payne, Gary A; Muddiman, David C
2010-03-05
Identification of proteins from proteolytic peptides or intact proteins plays an essential role in proteomics. Researchers use search engines to match the acquired peptide sequences to the target proteins. However, search engines depend on protein databases to provide candidates for consideration. Alternative splicing (AS), the mechanism where the exon of pre-mRNAs can be spliced and rearranged to generate distinct mRNA and therefore protein variants, enable higher eukaryotic organisms, with only a limited number of genes, to have the requisite complexity and diversity at the proteome level. Multiple alternative isoforms from one gene often share common segments of sequences. However, many protein databases only include a limited number of isoforms to keep minimal redundancy. As a result, the database search might not identify a target protein even with high quality tandem MS data and accurate intact precursor ion mass. We computationally predicted an exhaustive list of putative isoforms of Aspergillus flavus proteins from 20 371 expressed sequence tags to investigate whether an alternative splicing protein database can assign a greater proportion of mass spectrometry data. The newly constructed AS database provided 9807 new alternatively spliced variants in addition to 12 832 previously annotated proteins. The searches of the existing tandem MS spectra data set using the AS database identified 29 new proteins encoded by 26 genes. Nine fungal genes appeared to have multiple protein isoforms. In addition to the discovery of splice variants, AS database also showed potential to improve genome annotation. In summary, the introduction of an alternative splicing database helps identify more proteins and unveils more information about a proteome.
Jeffryes, James G; Colastani, Ricardo L; Elbadawi-Sidhu, Mona; Kind, Tobias; Niehaus, Thomas D; Broadbelt, Linda J; Hanson, Andrew D; Fiehn, Oliver; Tyo, Keith E J; Henry, Christopher S
2015-01-01
In spite of its great promise, metabolomics has proven difficult to execute in an untargeted and generalizable manner. Liquid chromatography-mass spectrometry (LC-MS) has made it possible to gather data on thousands of cellular metabolites. However, matching metabolites to their spectral features continues to be a bottleneck, meaning that much of the collected information remains uninterpreted and that new metabolites are seldom discovered in untargeted studies. These challenges require new approaches that consider compounds beyond those available in curated biochemistry databases. Here we present Metabolic In silico Network Expansions (MINEs), an extension of known metabolite databases to include molecules that have not been observed, but are likely to occur based on known metabolites and common biochemical reactions. We utilize an algorithm called the Biochemical Network Integrated Computational Explorer (BNICE) and expert-curated reaction rules based on the Enzyme Commission classification system to propose the novel chemical structures and reactions that comprise MINE databases. Starting from the Kyoto Encyclopedia of Genes and Genomes (KEGG) COMPOUND database, the MINE contains over 571,000 compounds, of which 93% are not present in the PubChem database. However, these MINE compounds have on average higher structural similarity to natural products than compounds from KEGG or PubChem. MINE databases were able to propose annotations for 98.6% of a set of 667 MassBank spectra, 14% more than KEGG alone and equivalent to PubChem while returning far fewer candidates per spectra than PubChem (46 vs. 1715 median candidates). Application of MINEs to LC-MS accurate mass data enabled the identity of an unknown peak to be confidently predicted. MINE databases are freely accessible for non-commercial use via user-friendly web-tools at http://minedatabase.mcs.anl.gov and developer-friendly APIs. MINEs improve metabolomics peak identification as compared to general chemical databases whose results include irrelevant synthetic compounds. Furthermore, MINEs complement and expand on previous in silico generated compound databases that focus on human metabolism. We are actively developing the database; future versions of this resource will incorporate transformation rules for spontaneous chemical reactions and more advanced filtering and prioritization of candidate structures. Graphical abstractMINE database construction and access methods. The process of constructing a MINE database from the curated source databases is depicted on the left. The methods for accessing the database are shown on the right.
Nakamura, Sayaka; Sato, Hiroaki; Tanaka, Reiko; Yaguchi, Takashi
2016-01-01
We have previously proposed a rapid identification method for bacterial strains based on the profiles of their ribosomal subunit proteins (RSPs), observed using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This method can perform phylogenetic characterization based on the mass of housekeeping RSP biomarkers, ideally calculated from amino acid sequence information registered in public protein databases. With the aim of extending its field of application to medical mycology, this study investigates the actual state of information of RSPs of eukaryotic fungi registered in public protein databases through the characterization of ribosomal protein fractions extracted from genome-sequenced Aspergillus fumigatus strains Af293 and A1163 as a model. In this process, we have found that the public protein databases harbor problems. The RSP names are in confusion, so we have provisionally unified them using the yeast naming system. The most serious problem is that many incorrect sequences are registered in the public protein databases. Surprisingly, more than half of the sequences are incorrect, due chiefly to mis-annotation of exon/intron structures. These errors could be corrected by a combination of in silico inspection by sequence homology analysis and MALDI-TOF MS measurements. We were also able to confirm conserved post-translational modifications in eleven RSPs. After these verifications, the masses of 31 expressed RSPs under 20,000 Da could be accurately confirmed. These RSPs have a potential to be useful biomarkers for identifying clinical isolates of A. fumigatus .
Barnes, Brian B.; Wilson, Michael B.; Carr, Peter W.; Vitha, Mark F.; Broeckling, Corey D.; Heuberger, Adam L.; Prenni, Jessica; Janis, Gregory C.; Corcoran, Henry; Snow, Nicholas H.; Chopra, Shilpi; Dhandapani, Ramkumar; Tawfall, Amanda; Sumner, Lloyd W.; Boswell, Paul G.
2014-01-01
Gas chromatography-mass spectrometry (GC-MS) is a primary tool used to identify compounds in complex samples. Both mass spectra and GC retention times are matched to those of standards, but it is often impractical to have standards on hand for every compound of interest, so we must rely on shared databases of MS data and GC retention information. Unfortunately, retention databases (e.g. linear retention index libraries) are experimentally restrictive, notoriously unreliable, and strongly instrument dependent, relegating GC retention information to a minor, often negligible role in compound identification despite its potential power. A new methodology called “retention projection” has great potential to overcome the limitations of shared chromatographic databases. In this work, we tested the reliability of the methodology in five independent laboratories. We found that even when each lab ran nominally the same method, the methodology was 3-fold more accurate than retention indexing because it properly accounted for unintentional differences between the GC-MS systems. When the labs used different methods of their own choosing, retention projections were 4- to 165-fold more accurate. More importantly, the distribution of error in the retention projections was predictable across different methods and labs, thus enabling automatic calculation of retention time tolerance windows. Tolerance windows at 99% confidence were generally narrower than those widely used even when physical standards are on hand to measure their retention. With its high accuracy and reliability, the new retention projection methodology makes GC retention a reliable, precise tool for compound identification, even when standards are not available to the user. PMID:24205931
Alanio, A; Beretti, J-L; Dauphin, B; Mellado, E; Quesne, G; Lacroix, C; Amara, A; Berche, P; Nassif, X; Bougnoux, M-E
2011-05-01
New Aspergillus species have recently been described with the use of multilocus sequencing in refractory cases of invasive aspergillosis. The classical phenotypic identification methods routinely used in clinical laboratories failed to identify them adequately. Some of these Aspergillus species have specific patterns of susceptibility to antifungal agents, and misidentification may lead to inappropriate therapy. We developed a matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS)-based strategy to adequately identify Aspergillus species to the species level. A database including the reference spectra of 28 clinically relevant species from seven Aspergillus sections (five common and 23 unusual species) was engineered. The profiles of young and mature colonies were analysed for each reference strain, and species-specific spectral fingerprints were identified. The performance of the database was then tested on 124 clinical and 16 environmental isolates previously characterized by partial sequencing of the β-tubulin and calmodulin genes. One hundred and thirty-eight isolates of 140 (98.6%) were correctly identified. Two atypical isolates could not be identified, but no isolate was misidentified (specificity: 100%). The database, including species-specific spectral fingerprints of young and mature colonies of the reference strains, allowed identification regardless of the maturity of the clinical isolate. These results indicate that MALDI-TOF MS is a powerful tool for rapid and accurate identification of both common and unusual species of Aspergillus. It can give better results than morphological identification in clinical laboratories. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.
Fiehn, Oliver
2016-01-01
Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small molecular metabolites (<650 daltons), including small acids, alcohols, hydroxyl acids, amino acids, sugars, fatty acids, sterols, catecholamines, drugs, and toxins, often using chemical derivatization to make these compounds volatile enough for gas chromatography. This unit shows that on GC-MS- based metabolomics easily allows integrating targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated, standardized standard operating procedures, GC-MS can identify and semi-quantify over 200 compounds per study in human body fluids (e.g., plasma, urine or stool) samples. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to liquid chromatography-MS untargeted profiling (LC-MS). Hence, GC-MS is a mature technology that not only uses classic detectors (‘quadrupole’) but also target mass spectrometers (‘triple quadrupole’) and accurate mass instruments (‘quadrupole-time of flight’). This unit covers the following aspects of GC-MS-based metabolomics: (i) sample preparation from mammalian samples, (ii) acquisition of data, (iii) quality control, and (iv) data processing. PMID:27038389
Lamy, Brigitte; Kodjo, Angeli; Laurent, Frédéric
2011-09-01
We evaluated the accuracy of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for identifying aeromonads with an extraction procedure. Genus-level accuracy was 100%. Compared to rpoB gene sequencing, species-level accuracy was 90.6% (29/32) for type and reference strains and 91.4% for a collection of 139 clinical and environmental isolates, making this system one of the most accurate and rapid methods for phenotypic identification. The reliability of this technique was very promising, although some improvements in database composition, taxonomy, and discriminatory power are needed. Copyright © 2011 Elsevier Inc. All rights reserved.
Zhu, Zhikai; Su, Xiaomeng; Go, Eden P; Desaire, Heather
2014-09-16
Glycoproteins are biologically significant large molecules that participate in numerous cellular activities. In order to obtain site-specific protein glycosylation information, intact glycopeptides, with the glycan attached to the peptide sequence, are characterized by tandem mass spectrometry (MS/MS) methods such as collision-induced dissociation (CID) and electron transfer dissociation (ETD). While several emerging automated tools are developed, no consensus is present in the field about the best way to determine the reliability of the tools and/or provide the false discovery rate (FDR). A common approach to calculate FDRs for glycopeptide analysis, adopted from the target-decoy strategy in proteomics, employs a decoy database that is created based on the target protein sequence database. Nonetheless, this approach is not optimal in measuring the confidence of N-linked glycopeptide matches, because the glycopeptide data set is considerably smaller compared to that of peptides, and the requirement of a consensus sequence for N-glycosylation further limits the number of possible decoy glycopeptides tested in a database search. To address the need to accurately determine FDRs for automated glycopeptide assignments, we developed GlycoPep Evaluator (GPE), a tool that helps to measure FDRs in identifying glycopeptides without using a decoy database. GPE generates decoy glycopeptides de novo for every target glycopeptide, in a 1:20 target-to-decoy ratio. The decoys, along with target glycopeptides, are scored against the ETD data, from which FDRs can be calculated accurately based on the number of decoy matches and the ratio of the number of targets to decoys, for small data sets. GPE is freely accessible for download and can work with any search engine that interprets ETD data of N-linked glycopeptides. The software is provided at https://desairegroup.ku.edu/research.
Bruderer, Tobias; Varesio, Emmanuel; Hidasi, Anita O; Duchoslav, Eva; Burton, Lyle; Bonner, Ron; Hopfgartner, Gérard
2018-03-01
High-quality mass spectral libraries have become crucial in mass spectrometry-based metabolomics. Here, we investigate a workflow to generate accurate mass discrete and composite spectral libraries for metabolite identification and for SWATH mass spectrometry data processing. Discrete collision energy (5-100 eV) accurate mass spectra were collected for 532 metabolites from the human metabolome database (HMDB) by flow injection analysis and compiled into composite spectra over a large collision energy range (e.g., 10-70 eV). Full scan response factors were also calculated. Software tools based on accurate mass and predictive fragmentation were specially developed and found to be essential for construction and quality control of the spectral library. First, elemental compositions constrained by the elemental composition of the precursor ion were calculated for all fragments. Secondly, all possible fragments were generated from the compound structure and were filtered based on their elemental compositions. From the discrete spectra, it was possible to analyze the specific fragment form at each collision energy and it was found that a relatively large collision energy range (10-70 eV) gives informative MS/MS spectra for library searches. From the composite spectra, it was possible to characterize specific neutral losses as radical losses using in silico fragmentation. Radical losses (generating radical cations) were found to be more prominent than expected. From 532 metabolites, 489 provided a signal in positive mode [M+H] + and 483 in negative mode [M-H] - . MS/MS spectra were obtained for 399 compounds in positive mode and for 462 in negative mode; 329 metabolites generated suitable spectra in both modes. Using the spectral library, LC retention time, response factors to analyze data-independent LC-SWATH-MS data allowed the identification of 39 (positive mode) and 72 (negative mode) metabolites in a plasma pool sample (total 92 metabolites) where 81 previously were reported in HMDB to be found in plasma. Graphical abstract Library generation workflow for LC-SWATH MS, using collision energy spread, accurate mass, and fragment annotation.
2010-01-01
Background Accurate identification is necessary to discriminate harmless environmental Yersinia species from the food-borne pathogens Yersinia enterocolitica and Yersinia pseudotuberculosis and from the group A bioterrorism plague agent Yersinia pestis. In order to circumvent the limitations of current phenotypic and PCR-based identification methods, we aimed to assess the usefulness of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) protein profiling for accurate and rapid identification of Yersinia species. As a first step, we built a database of 39 different Yersinia strains representing 12 different Yersinia species, including 13 Y. pestis isolates representative of the Antiqua, Medievalis and Orientalis biotypes. The organisms were deposited on the MALDI-TOF plate after appropriate ethanol-based inactivation, and a protein profile was obtained within 6 minutes for each of the Yersinia species. Results When compared with a 3,025-profile database, every Yersinia species yielded a unique protein profile and was unambiguously identified. In the second step of analysis, environmental and clinical isolates of Y. pestis (n = 2) and Y. enterocolitica (n = 11) were compared to the database and correctly identified. In particular, Y. pestis was unambiguously identified at the species level, and MALDI-TOF was able to successfully differentiate the three biotypes. Conclusion These data indicate that MALDI-TOF can be used as a rapid and accurate first-line method for the identification of Yersinia isolates. PMID:21073689
Ayyadurai, Saravanan; Flaudrops, Christophe; Raoult, Didier; Drancourt, Michel
2010-11-12
Accurate identification is necessary to discriminate harmless environmental Yersinia species from the food-borne pathogens Yersinia enterocolitica and Yersinia pseudotuberculosis and from the group A bioterrorism plague agent Yersinia pestis. In order to circumvent the limitations of current phenotypic and PCR-based identification methods, we aimed to assess the usefulness of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) protein profiling for accurate and rapid identification of Yersinia species. As a first step, we built a database of 39 different Yersinia strains representing 12 different Yersinia species, including 13 Y. pestis isolates representative of the Antiqua, Medievalis and Orientalis biotypes. The organisms were deposited on the MALDI-TOF plate after appropriate ethanol-based inactivation, and a protein profile was obtained within 6 minutes for each of the Yersinia species. When compared with a 3,025-profile database, every Yersinia species yielded a unique protein profile and was unambiguously identified. In the second step of analysis, environmental and clinical isolates of Y. pestis (n = 2) and Y. enterocolitica (n = 11) were compared to the database and correctly identified. In particular, Y. pestis was unambiguously identified at the species level, and MALDI-TOF was able to successfully differentiate the three biotypes. These data indicate that MALDI-TOF can be used as a rapid and accurate first-line method for the identification of Yersinia isolates.
Mass spectrometry-based protein identification with accurate statistical significance assignment.
Alves, Gelio; Yu, Yi-Kuo
2015-03-01
Assigning statistical significance accurately has become increasingly important as metadata of many types, often assembled in hierarchies, are constructed and combined for further biological analyses. Statistical inaccuracy of metadata at any level may propagate to downstream analyses, undermining the validity of scientific conclusions thus drawn. From the perspective of mass spectrometry-based proteomics, even though accurate statistics for peptide identification can now be achieved, accurate protein level statistics remain challenging. We have constructed a protein ID method that combines peptide evidences of a candidate protein based on a rigorous formula derived earlier; in this formula the database P-value of every peptide is weighted, prior to the final combination, according to the number of proteins it maps to. We have also shown that this protein ID method provides accurate protein level E-value, eliminating the need of using empirical post-processing methods for type-I error control. Using a known protein mixture, we find that this protein ID method, when combined with the Sorić formula, yields accurate values for the proportion of false discoveries. In terms of retrieval efficacy, the results from our method are comparable with other methods tested. The source code, implemented in C++ on a linux system, is available for download at ftp://ftp.ncbi.nlm.nih.gov/pub/qmbp/qmbp_ms/RAId/RAId_Linux_64Bit. Published by Oxford University Press 2014. This work is written by US Government employees and is in the public domain in the US.
Xu, Zhenzhen; Li, Jianzhong; Chen, Ailiang; Ma, Xin; Yang, Shuming
2018-05-03
The retrospectivity (the ability to retrospect to a previously unknown compound in raw data) is very meaningful for food safety and risk assessment when facing new emerging drugs. Accurate mass and retention time based screening may lead false positive and false negative results so new retrospective, reliable platform is desirable. Different concentration levels of standards with and without matrix were analyzed using ion mobility (IM)-quadrupole-time-of-flight (Q-TOF) for collecting retrospective accurate mass, retention time, drift time and tandem MS evidence for identification in a single experiment. The isomer separation ability of IM and the four-dimensional (4D) feature abundance quantification abilities were evaluated for veterinary drugs for the first time. The sensitivity of the IM-Q-TOF workflow was obviously higher than that of the traditional database searching algorithm [find by formula (FbF) function] for Q-TOF. In addition, the IM-Q-TOF workflow contained most of the results from FbF and removed the false positive results. Some isomers were separated by IM and the 4D feature abundance quantitation removed interference with similar accurate mass and showed good linearity. A new retrospective, multi-evidence platform was built for veterinary drug screening in a single experiment. The sensitivity was significantly improved and the data can be used for quantification. The platform showed its potential to be used for food safety and risk assessment. This article is protected by copyright. All rights reserved.
Ferro, Myriam; Brugière, Sabine; Salvi, Daniel; Seigneurin-Berny, Daphné; Court, Magali; Moyet, Lucas; Ramus, Claire; Miras, Stéphane; Mellal, Mourad; Le Gall, Sophie; Kieffer-Jaquinod, Sylvie; Bruley, Christophe; Garin, Jérôme; Joyard, Jacques; Masselon, Christophe; Rolland, Norbert
2010-06-01
Recent advances in the proteomics field have allowed a series of high throughput experiments to be conducted on chloroplast samples, and the data are available in several public databases. However, the accurate localization of many chloroplast proteins often remains hypothetical. This is especially true for envelope proteins. We went a step further into the knowledge of the chloroplast proteome by focusing, in the same set of experiments, on the localization of proteins in the stroma, the thylakoids, and envelope membranes. LC-MS/MS-based analyses first allowed building the AT_CHLORO database (http://www.grenoble.prabi.fr/protehome/grenoble-plant-proteomics/), a comprehensive repertoire of the 1323 proteins, identified by 10,654 unique peptide sequences, present in highly purified chloroplasts and their subfractions prepared from Arabidopsis thaliana leaves. This database also provides extensive proteomics information (peptide sequences and molecular weight, chromatographic retention times, MS/MS spectra, and spectral count) for a unique chloroplast protein accurate mass and time tag database gathering identified peptides with their respective and precise analytical coordinates, molecular weight, and retention time. We assessed the partitioning of each protein in the three chloroplast compartments by using a semiquantitative proteomics approach (spectral count). These data together with an in-depth investigation of the literature were compiled to provide accurate subplastidial localization of previously known and newly identified proteins. A unique knowledge base containing extensive information on the proteins identified in envelope fractions was thus obtained, allowing new insights into this membrane system to be revealed. Altogether, the data we obtained provide unexpected information about plastidial or subplastidial localization of some proteins that were not suspected to be associated to this membrane system. The spectral counting-based strategy was further validated as the compartmentation of well known pathways (for instance, photosynthesis and amino acid, fatty acid, or glycerolipid biosynthesis) within chloroplasts could be dissected. It also allowed revisiting the compartmentation of the chloroplast metabolism and functions.
Gapped Spectral Dictionaries and Their Applications for Database Searches of Tandem Mass Spectra*
Jeong, Kyowon; Kim, Sangtae; Bandeira, Nuno; Pevzner, Pavel A.
2011-01-01
Generating all plausible de novo interpretations of a peptide tandem mass (MS/MS) spectrum (Spectral Dictionary) and quickly matching them against the database represent a recently emerged alternative approach to peptide identification. However, the sizes of the Spectral Dictionaries quickly grow with the peptide length making their generation impractical for long peptides. We introduce Gapped Spectral Dictionaries (all plausible de novo interpretations with gaps) that can be easily generated for any peptide length thus addressing the limitation of the Spectral Dictionary approach. We show that Gapped Spectral Dictionaries are small thus opening a possibility of using them to speed-up MS/MS searches. Our MS-GappedDictionary algorithm (based on Gapped Spectral Dictionaries) enables proteogenomics applications (such as searches in the six-frame translation of the human genome) that are prohibitively time consuming with existing approaches. MS-GappedDictionary generates gapped peptides that occupy a niche between accurate but short peptide sequence tags and long but inaccurate full length peptide reconstructions. We show that, contrary to conventional wisdom, some high-quality spectra do not have good peptide sequence tags and introduce gapped tags that have advantages over the conventional peptide sequence tags in MS/MS database searches. PMID:21444829
Nakamura, Sayaka; Sato, Hiroaki; Tanaka, Reiko; Yaguchi, Takashi
2016-01-01
We have previously proposed a rapid identification method for bacterial strains based on the profiles of their ribosomal subunit proteins (RSPs), observed using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This method can perform phylogenetic characterization based on the mass of housekeeping RSP biomarkers, ideally calculated from amino acid sequence information registered in public protein databases. With the aim of extending its field of application to medical mycology, this study investigates the actual state of information of RSPs of eukaryotic fungi registered in public protein databases through the characterization of ribosomal protein fractions extracted from genome-sequenced Aspergillus fumigatus strains Af293 and A1163 as a model. In this process, we have found that the public protein databases harbor problems. The RSP names are in confusion, so we have provisionally unified them using the yeast naming system. The most serious problem is that many incorrect sequences are registered in the public protein databases. Surprisingly, more than half of the sequences are incorrect, due chiefly to mis-annotation of exon/intron structures. These errors could be corrected by a combination of in silico inspection by sequence homology analysis and MALDI-TOF MS measurements. We were also able to confirm conserved post-translational modifications in eleven RSPs. After these verifications, the masses of 31 expressed RSPs under 20,000 Da could be accurately confirmed. These RSPs have a potential to be useful biomarkers for identifying clinical isolates of A. fumigatus. PMID:27843740
2014-01-01
Despite recent advances in analytical and computational chemistry, lipid identification remains a significant challenge in lipidomics. Ion-mobility spectrometry provides an accurate measure of the molecules’ rotationally averaged collision cross-section (CCS) in the gas phase and is thus related to ionic shape. Here, we investigate the use of CCS as a highly specific molecular descriptor for identifying lipids in biological samples. Using traveling wave ion mobility mass spectrometry (MS), we measured the CCS values of over 200 lipids within multiple chemical classes. CCS values derived from ion mobility were not affected by instrument settings or chromatographic conditions, and they were highly reproducible on instruments located in independent laboratories (interlaboratory RSD < 3% for 98% of molecules). CCS values were used as additional molecular descriptors to identify brain lipids using a variety of traditional lipidomic approaches. The addition of CCS improved the reproducibility of analysis in a liquid chromatography-MS workflow and maximized the separation of isobaric species and the signal-to-noise ratio in direct-MS analyses (e.g., “shotgun” lipidomics and MS imaging). These results indicate that adding CCS to databases and lipidomics workflows increases the specificity and selectivity of analysis, thus improving the confidence in lipid identification compared to traditional analytical approaches. The CCS/accurate-mass database described here is made publicly available. PMID:25495617
Wang, Xiupin; Peng, Qingzhi; Li, Peiwu; Zhang, Qi; Ding, Xiaoxia; Zhang, Wen; Zhang, Liangxiao
2016-10-12
High complexity of identification for non-target triacylglycerols (TAGs) is a major challenge in lipidomics analysis. To identify non-target TAGs, a powerful tool named accurate MS(n) spectrometry generating so-called ion trees is used. In this paper, we presented a technique for efficient structural elucidation of TAGs on MS(n) spectral trees produced by LTQ Orbitrap MS(n), which was implemented as an open source software package, or TIT. The TIT software was used to support automatic annotation of non-target TAGs on MS(n) ion trees from a self-built fragment ion database. This database includes 19108 simulate TAG molecules from a random combination of fatty acids and corresponding 500582 self-built multistage fragment ions (MS ≤ 3). Our software can identify TAGs using a "stage-by-stage elimination" strategy. By utilizing the MS(1) accurate mass and referenced RKMD, the TIT software can discriminate unique elemental composition candidates. The regiospecific isomers of fatty acyl chains will be distinguished using MS(2) and MS(3) fragment spectra. We applied the algorithm to the selection of 45 TAG standards and demonstrated that the molecular ions could be 100% correctly assigned. Therefore, the TIT software could be applied to TAG identification in complex biological samples such as mouse plasma extracts. Copyright © 2016 Elsevier B.V. All rights reserved.
What Is New in Clinical Microbiology—Microbial Identification by MALDI-TOF Mass Spectrometry
Murray, Patrick R.
2012-01-01
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) offers the possibility of accurate, rapid, inexpensive identification of bacteria, fungi, and mycobacteria isolated in clinical microbiology laboratories. The procedures for preanalytic processing of organisms and analysis by MALDI-TOF MS are technically simple and reproducible, and commercial databases and interpretive algorithms are available for the identification of a wide spectrum of clinically significant organisms. Although only limited work has been reported on the use of this technique to identify molds, perform strain typing, or determine antibiotic susceptibility results, these are fruitful areas of promising research. As experience is gained with MALDI-TOF MS, it is expected that the databases will be expanded to resolve many of the current inadequate identifications (eg, no identification, genus-level identification) and algorithms for potential misidentification will be developed. The current lack of Food and Drug Administration approval of any MALDI-TOF MS system for organism identification limits widespread use in the United States. PMID:22795961
Kind, Tobias; Fiehn, Oliver
2007-01-01
Background Structure elucidation of unknown small molecules by mass spectrometry is a challenge despite advances in instrumentation. The first crucial step is to obtain correct elemental compositions. In order to automatically constrain the thousands of possible candidate structures, rules need to be developed to select the most likely and chemically correct molecular formulas. Results An algorithm for filtering molecular formulas is derived from seven heuristic rules: (1) restrictions for the number of elements, (2) LEWIS and SENIOR chemical rules, (3) isotopic patterns, (4) hydrogen/carbon ratios, (5) element ratio of nitrogen, oxygen, phosphor, and sulphur versus carbon, (6) element ratio probabilities and (7) presence of trimethylsilylated compounds. Formulas are ranked according to their isotopic patterns and subsequently constrained by presence in public chemical databases. The seven rules were developed on 68,237 existing molecular formulas and were validated in four experiments. First, 432,968 formulas covering five million PubChem database entries were checked for consistency. Only 0.6% of these compounds did not pass all rules. Next, the rules were shown to effectively reducing the complement all eight billion theoretically possible C, H, N, S, O, P-formulas up to 2000 Da to only 623 million most probable elemental compositions. Thirdly 6,000 pharmaceutical, toxic and natural compounds were selected from DrugBank, TSCA and DNP databases. The correct formulas were retrieved as top hit at 80–99% probability when assuming data acquisition with complete resolution of unique compounds and 5% absolute isotope ratio deviation and 3 ppm mass accuracy. Last, some exemplary compounds were analyzed by Fourier transform ion cyclotron resonance mass spectrometry and by gas chromatography-time of flight mass spectrometry. In each case, the correct formula was ranked as top hit when combining the seven rules with database queries. Conclusion The seven rules enable an automatic exclusion of molecular formulas which are either wrong or which contain unlikely high or low number of elements. The correct molecular formula is assigned with a probability of 98% if the formula exists in a compound database. For truly novel compounds that are not present in databases, the correct formula is found in the first three hits with a probability of 65–81%. Corresponding software and supplemental data are available for downloads from the authors' website. PMID:17389044
Total choline and choline-containing moieties of commercially available pulses.
Lewis, Erin D; Kosik, Sarah J; Zhao, Yuan-Yuan; Jacobs, René L; Curtis, Jonathan M; Field, Catherine J
2014-06-01
Estimating dietary choline intake can be challenging due to missing foods in the current United States Department of Agriculture (USDA) database. The objectives of the study were to quantify the choline-containing moieties and the total choline content of a variety of pulses available in North America and use the expanded compositional database to determine the potential contribution of pulses to dietary choline intake. Commonly consumed pulses (n = 32) were analyzed by hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC LC-MS/MS) and compared to the current USDA database. Cooking was found to reduce the relative percent from free choline and increased the contribution of phosphatidylcholine to total choline for most pulses (P < 0.05). Using the expanded database to estimate choline content of recipes using pulses as meat alternatives, resulted in a different estimation of choline content per serving (±30%), compared to the USDA database. These results suggest that when pulses are a large part of a meal or diet, the use of accurate food composition data should be used.
Shteynberg, David; Deutsch, Eric W.; Lam, Henry; Eng, Jimmy K.; Sun, Zhi; Tasman, Natalie; Mendoza, Luis; Moritz, Robert L.; Aebersold, Ruedi; Nesvizhskii, Alexey I.
2011-01-01
The combination of tandem mass spectrometry and sequence database searching is the method of choice for the identification of peptides and the mapping of proteomes. Over the last several years, the volume of data generated in proteomic studies has increased dramatically, which challenges the computational approaches previously developed for these data. Furthermore, a multitude of search engines have been developed that identify different, overlapping subsets of the sample peptides from a particular set of tandem mass spectrometry spectra. We present iProphet, the new addition to the widely used open-source suite of proteomic data analysis tools Trans-Proteomics Pipeline. Applied in tandem with PeptideProphet, it provides more accurate representation of the multilevel nature of shotgun proteomic data. iProphet combines the evidence from multiple identifications of the same peptide sequences across different spectra, experiments, precursor ion charge states, and modified states. It also allows accurate and effective integration of the results from multiple database search engines applied to the same data. The use of iProphet in the Trans-Proteomics Pipeline increases the number of correctly identified peptides at a constant false discovery rate as compared with both PeptideProphet and another state-of-the-art tool Percolator. As the main outcome, iProphet permits the calculation of accurate posterior probabilities and false discovery rate estimates at the level of sequence identical peptide identifications, which in turn leads to more accurate probability estimates at the protein level. Fully integrated with the Trans-Proteomics Pipeline, it supports all commonly used MS instruments, search engines, and computer platforms. The performance of iProphet is demonstrated on two publicly available data sets: data from a human whole cell lysate proteome profiling experiment representative of typical proteomic data sets, and from a set of Streptococcus pyogenes experiments more representative of organism-specific composite data sets. PMID:21876204
Accurately Mapping M31's Microlensing Population
NASA Astrophysics Data System (ADS)
Crotts, Arlin
2004-07-01
We propose to augment an existing microlensing survey of M31 with source identifications provided by a modest amount of ACS {and WFPC2 parallel} observations to yield an accurate measurement of the masses responsible for microlensing in M31, and presumably much of its dark matter. The main benefit of these data is the determination of the physical {or "einstein"} timescale of each microlensing event, rather than an effective {"FWHM"} timescale, allowing masses to be determined more than twice as accurately as without HST data. The einstein timescale is the ratio of the lensing cross-sectional radius and relative velocities. Velocities are known from kinematics, and the cross-section is directly proportional to the {unknown} lensing mass. We cannot easily measure these quantities without knowing the amplification, hence the baseline magnitude, which requires the resolution of HST to find the source star. This makes a crucial difference because M31 lens m ass determinations can be more accurate than those towards the Magellanic Clouds through our Galaxy's halo {for the same number of microlensing events} due to the better constrained geometry in the M31 microlensing situation. Furthermore, our larger survey, just completed, should yield at least 100 M31 microlensing events, more than any Magellanic survey. A small amount of ACS+WFPC2 imaging will deliver the potential of this large database {about 350 nights}. For the whole survey {and a delta-function mass distribution} the mass error should approach only about 15%, or about 6% error in slope for a power-law distribution. These results will better allow us to pinpoint the lens halo fraction, and the shape of the halo lens spatial distribution, and allow generalization/comparison of the nature of halo dark matter in spiral galaxies. In addition, we will be able to establish the baseline magnitude for about 50, 000 variable stars, as well as measure an unprecedentedly deta iled color-magnitude diagram and luminosity function over much of M31.
Linking high resolution mass spectrometry data with exposure ...
There is a growing need in the field of exposure science for monitoring methods that rapidly screen environmental media for suspect contaminants. Measurement and analysis platforms, based on high resolution mass spectrometry (HRMS), now exist to meet this need. Here we describe results of a study that links HRMS data with exposure predictions from the U.S. EPA's ExpoCast™ program and in vitro bioassay data from the U.S. interagency Tox21 consortium. Vacuum dust samples were collected from 56 households across the U.S. as part of the American Healthy Homes Survey (AHHS). Sample extracts were analyzed using liquid chromatography time-of-flight mass spectrometry (LC–TOF/MS) with electrospray ionization. On average, approximately 2000 molecular features were identified per sample (based on accurate mass) in negative ion mode, and 3000 in positive ion mode. Exact mass, isotope distribution, and isotope spacing were used to match molecular features with a unique listing of chemical formulas extracted from EPA's Distributed Structure-Searchable Toxicity (DSSTox) database. A total of 978 DSSTox formulas were consistent with the dust LC–TOF/molecular feature data (match score ≥ 90); these formulas mapped to 3228 possible chemicals in the database. Correct assignment of a unique chemical to a given formula required additional validation steps. Each suspect chemical was prioritized for follow-up confirmation using abundance and detection frequency results, along wi
There is a growing need in the field of exposure science for monitoring methods that rapidly screen environmental media for suspect contaminants. Measurement and analysis platforms, based on high resolution mass spectrometry (HRMS), now exist to meet this need. Here we describe results of a study that links HRMS data with exposure predictions from the U.S. EPA's ExpoCast? program and in vitro bioassay data from the U.S. interagency Tox21 consortium. Vacuum dust samples were collected from 56 households across the U.S. as part of the American Healthy Homes Survey (AHHS). Sample extracts were analyzed using liquid chromatography time-of-flight mass spectrometry (LC??TOF/MS) with electrospray ionization. On average, approximately 2000 molecular features were identified per sample (based on accurate mass) in negative ion mode, and 3000 in positive ion mode. Exact mass, isotope distribution, and isotope spacing were used to match molecular features with a unique listing of chemical formulas extracted from EPA's Distributed Structure-Searchable Toxicity (DSSTox) database. A total of 978 DSSTox formulas were consistent with the dust LC??TOF/molecular feature data (match score ? 90); these formulas mapped to 3228 possible chemicals in the database. Correct assignment of a unique chemical to a given formula required additional validation steps. Each suspect chemical was prioritized for follow-up confirmation using abundance and detection frequency results, along with exp
Cao, Mingshu; Fraser, Karl; Rasmussen, Susanne
2013-10-31
Mass spectrometry coupled with chromatography has become the major technical platform in metabolomics. Aided by peak detection algorithms, the detected signals are characterized by mass-over-charge ratio (m/z) and retention time. Chemical identities often remain elusive for the majority of the signals. Multi-stage mass spectrometry based on electrospray ionization (ESI) allows collision-induced dissociation (CID) fragmentation of selected precursor ions. These fragment ions can assist in structural inference for metabolites of low molecular weight. Computational investigations of fragmentation spectra have increasingly received attention in metabolomics and various public databases house such data. We have developed an R package "iontree" that can capture, store and analyze MS2 and MS3 mass spectral data from high throughput metabolomics experiments. The package includes functions for ion tree construction, an algorithm (distMS2) for MS2 spectral comparison, and tools for building platform-independent ion tree (MS2/MS3) libraries. We have demonstrated the utilization of the package for the systematic analysis and annotation of fragmentation spectra collected in various metabolomics platforms, including direct infusion mass spectrometry, and liquid chromatography coupled with either low resolution or high resolution mass spectrometry. Assisted by the developed computational tools, we have demonstrated that spectral trees can provide informative evidence complementary to retention time and accurate mass to aid with annotating unknown peaks. These experimental spectral trees once subjected to a quality control process, can be used for querying public MS2 databases or de novo interpretation. The putatively annotated spectral trees can be readily incorporated into reference libraries for routine identification of metabolites.
de Almeida, João N; Sztajnbok, Jaques; da Silva, Afonso Rafael; Vieira, Vinicius Adriano; Galastri, Anne Layze; Bissoli, Leandro; Litvinov, Nadia; Del Negro, Gilda Maria Barbaro; Motta, Adriana Lopes; Rossi, Flávia; Benard, Gil
2016-11-01
Moulds and arthroconidial yeasts are potential life-threatening agents of fungemia in immunocompromised patients. Fast and accurate identification (ID) of these pathogens hastens initiation of targeted antifungal therapy, thereby improving the patients' prognosis. We describe a new strategy that enabled the identification of moulds and arthroconidial yeasts directly from positive blood cultures by MALDI-TOF mass spectrometry (MS). Positive blood cultures (BCs) with Gram staining showing hyphae and/or arthroconidia were prospectively selected and submitted to an in-house protein extraction protocol. Mass spectra were obtained by Vitek MS™ system, and identifications were carried out with in the research use only (RUO) mode with an extended database (SARAMIS™ [v.4.12] plus in-house database). Fusarium solani, Fusarium verticillioides, Exophiala dermatitidis, Saprochaete clavata, and Trichosporon asahii had correct species ID by MALDI-TOF MS analysis of positive BCs. All cases were related to critically ill patients with high mortality fungemia and direct ID from positive BCs was helpful for rapid administration of targeted antifungal therapy. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Characterization of Proteoforms with Unknown Post-translational Modifications Using the MIScore
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kou, Qiang; Zhu, Binhai; Wu, Si
Various proteoforms may be generated from a single gene due to primary structure alterations (PSAs) such as genetic variations, alternative splicing, and post-translational modifications (PTMs). Top-down mass spectrometry is capable of analyzing intact proteins and identifying patterns of multiple PSAs, making it the method of choice for studying complex proteoforms. In top-down proteomics, proteoform identification is often performed by searching tandem mass spectra against a protein sequence database that contains only one reference protein sequence for each gene or transcript variant in a proteome. Because of the incompleteness of the protein database, an identified proteoform may contain unknown PSAs comparedmore » with the reference sequence. Proteoform characterization is to identify and localize PSAs in a proteoform. Although many software tools have been proposed for proteoform identification by top-down mass spectrometry, the characterization of proteoforms in identified proteoform-spectrum matches still relies mainly on manual annotation. We propose to use the Modification Identification Score (MIScore), which is based on Bayesian models, to automatically identify and localize PTMs in proteoforms. Experiments showed that the MIScore is accurate in identifying and localizing one or two modifications.« less
HST Proper Motions of Distant Globular Clusters: Constraining the Formation & Mass of the Milky Way
NASA Astrophysics Data System (ADS)
Sohn, S. Tony; van der Marel, Roeland P.; Deason, Alis; Bellini, Andrea; Besla, Gurtina; Watkins, Laura
2018-04-01
Proper motions (PMs) are required to calculate accurate orbits of globular clusters (GCs) in the Milky Way (MW) halo. We present our HST program to create a PM database for 20 GCs at distances of R GC = 10-100 kpc. Targets are discussed along with PM measurement methods. We also describe how our PM results can be used for Gaia as an external check, and discuss the synergy between HST and Gaia as astrometric instruments in the coming years.
Lasch, Peter; Wahab, Tara; Weil, Sandra; Pályi, Bernadett; Tomaso, Herbert; Zange, Sabine; Kiland Granerud, Beathe; Drevinek, Michal; Kokotovic, Branko; Wittwer, Matthias; Pflüger, Valentin; Di Caro, Antonino; Stämmler, Maren; Grunow, Roland
2015-01-01
In the case of a release of highly pathogenic bacteria (HPB), there is an urgent need for rapid, accurate, and reliable diagnostics. MALDI-TOF mass spectrometry is a rapid, accurate, and relatively inexpensive technique that is becoming increasingly important in microbiological diagnostics to complement classical microbiology, PCR, and genotyping of HPB. In the present study, the results of a joint exercise with 11 partner institutions from nine European countries are presented. In this exercise, 10 distinct microbial samples, among them five HPB, Bacillus anthracis, Brucella canis, Burkholderia mallei, Burkholderia pseudomallei, and Yersinia pestis, were characterized under blinded conditions. Microbial strains were inactivated by high-dose gamma irradiation before shipment. Preparatory investigations ensured that this type of inactivation induced only subtle spectral changes with negligible influence on the quality of the diagnosis. Furthermore, pilot tests on nonpathogenic strains were systematically conducted to ensure the suitability of sample preparation and to optimize and standardize the workflow for microbial identification. The analysis of the microbial mass spectra was carried out by the individual laboratories on the basis of spectral libraries available on site. All mass spectra were also tested against an in-house HPB library at the Robert Koch Institute (RKI). The averaged identification accuracy was 77% in the first case and improved to >93% when the spectral diagnoses were obtained on the basis of the RKI library. The compilation of complete and comprehensive databases with spectra from a broad strain collection is therefore considered of paramount importance for accurate microbial identification. PMID:26063856
Classification of Ancient Mammal Individuals Using Dental Pulp MALDI-TOF MS Peptide Profiling
Tran, Thi-Nguyen-Ny; Aboudharam, Gérard; Gardeisen, Armelle; Davoust, Bernard; Bocquet-Appel, Jean-Pierre; Flaudrops, Christophe; Belghazi, Maya; Raoult, Didier; Drancourt, Michel
2011-01-01
Background The classification of ancient animal corpses at the species level remains a challenging task for forensic scientists and anthropologists. Severe damage and mixed, tiny pieces originating from several skeletons may render morphological classification virtually impossible. Standard approaches are based on sequencing mitochondrial and nuclear targets. Methodology/Principal Findings We present a method that can accurately classify mammalian species using dental pulp and mass spectrometry peptide profiling. Our work was organized into three successive steps. First, after extracting proteins from the dental pulp collected from 37 modern individuals representing 13 mammalian species, trypsin-digested peptides were used for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis. The resulting peptide profiles accurately classified every individual at the species level in agreement with parallel cytochrome b gene sequencing gold standard. Second, using a 279–modern spectrum database, we blindly classified 33 of 37 teeth collected in 37 modern individuals (89.1%). Third, we classified 10 of 18 teeth (56%) collected in 15 ancient individuals representing five mammal species including human, from five burial sites dating back 8,500 years. Further comparison with an upgraded database comprising ancient specimen profiles yielded 100% classification in ancient teeth. Peptide sequencing yield 4 and 16 different non-keratin proteins including collagen (alpha-1 type I and alpha-2 type I) in human ancient and modern dental pulp, respectively. Conclusions/Significance Mass spectrometry peptide profiling of the dental pulp is a new approach that can be added to the arsenal of species classification tools for forensics and anthropology as a complementary method to DNA sequencing. The dental pulp is a new source for collagen and other proteins for the species classification of modern and ancient mammal individuals. PMID:21364886
He, Min; Wu, Hai; Nie, Juan; Yan, Pan; Yang, Tian-Biao; Yang, Zhi-Yu; Pei, Rui
2017-11-30
In this study, Liquid Chromatography (LC) separation combined with quadrupole-Time-Of-Flight Mass Spectrometry (qTOF-MS) detection was used to analyze the characteristic ions of the flavonoids from Liang-wai Gan Cao (Radix Glycyrrhizae uralensis). First, accurate mass measurement and isotope curve optimization could provide reliable molecular prediction after noise deduction, baseline calibration and "ghost peak recognition". Thus, some spectral features in the LC-MS data could be clearly explained. Secondly, the chemical structure of flavonoids was deduced by MS/MS fragment ions, and the in-silico spectra by MS-FINDER program provided strong support for overcoming the bottleneck of phytochemical identification. For a predicted formula and experimental MS/MS spectrum, the MS-FINDER program could sort the candidate compounds in the public database based on a comprehensive weighted score, and we took the first 20 reliable compounds to seek the target compound in an in-house database. Certainly, those fragmentation pathways could also be deduced and described as Retro-Diels-Alder (RDA) fragmentation reaction, losses of C 4 H 8 , C 5 H 8 , CH 3 , CO, CO 2 and others. Accordingly, 63 flavonoids were identified, and their in-silico bioactivity were clearly disclosed by some bioinformatics tools. In this experiment, the flavonoids obtained by the four extraction processes were tested by LC-qTOF-MS. We looked for possible Q-markers from these data matrices and then quantified them; their similarities/differences were also described. The results also indicated that the Macroporous Adsorption Resins (MARs) purification is a low cost, environmentally friendly and effective approach. Copyright © 2017 Elsevier B.V. All rights reserved.
Ojima-Kato, Teruyo; Yamamoto, Naomi; Takahashi, Hajime; Tamura, Hiroto
2016-01-01
The genetic lineages of Listeria monocytogenes and other species of the genus Listeria are correlated with pathogenesis in humans. Although matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has become a prevailing tool for rapid and reliable microbial identification, the precise discrimination of Listeria species and lineages remains a crucial issue in clinical settings and for food safety. In this study, we constructed an accurate and reliable MS database to discriminate the lineages of L. monocytogenes and the species of Listeria (L. monocytogenes, L. innocua, L. welshimeri, L. seeligeri, L. ivanovii, L. grayi, and L. rocourtiae) based on the S10-spc-alpha operon gene encoded ribosomal protein mass spectrum (S10-GERMS) proteotyping method, which relies on both genetic information (genomics) and observed MS peaks in MALDI-TOF MS (proteomics). The specific set of eight biomarkers (ribosomal proteins L24, L6, L18, L15, S11, S9, L31 type B, and S16) yielded characteristic MS patterns for the lineages of L. monocytogenes and the different species of Listeria, and led to the construction of a MS database that was successful in discriminating between these organisms in MALDI-TOF MS fingerprinting analysis followed by advanced proteotyping software Strain Solution analysis. We also confirmed the constructed database on the proteotyping software Strain Solution by using 23 Listeria strains collected from natural sources.
Yamamoto, Naomi; Takahashi, Hajime; Tamura, Hiroto
2016-01-01
The genetic lineages of Listeria monocytogenes and other species of the genus Listeria are correlated with pathogenesis in humans. Although matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has become a prevailing tool for rapid and reliable microbial identification, the precise discrimination of Listeria species and lineages remains a crucial issue in clinical settings and for food safety. In this study, we constructed an accurate and reliable MS database to discriminate the lineages of L. monocytogenes and the species of Listeria (L. monocytogenes, L. innocua, L. welshimeri, L. seeligeri, L. ivanovii, L. grayi, and L. rocourtiae) based on the S10-spc-alpha operon gene encoded ribosomal protein mass spectrum (S10-GERMS) proteotyping method, which relies on both genetic information (genomics) and observed MS peaks in MALDI-TOF MS (proteomics). The specific set of eight biomarkers (ribosomal proteins L24, L6, L18, L15, S11, S9, L31 type B, and S16) yielded characteristic MS patterns for the lineages of L. monocytogenes and the different species of Listeria, and led to the construction of a MS database that was successful in discriminating between these organisms in MALDI-TOF MS fingerprinting analysis followed by advanced proteotyping software Strain Solution analysis. We also confirmed the constructed database on the proteotyping software Strain Solution by using 23 Listeria strains collected from natural sources. PMID:27442502
Raharimalala, F N; Andrianinarivomanana, T M; Rakotondrasoa, A; Collard, J M; Boyer, S
2017-09-01
Arthropod-borne diseases are important causes of morbidity and mortality. The identification of vector species relies mainly on morphological features and/or molecular biology tools. The first method requires specific technical skills and may result in misidentifications, and the second method is time-consuming and expensive. The aim of the present study is to assess the usefulness and accuracy of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) as a supplementary tool with which to identify mosquito vector species and to invest in the creation of an international database. A total of 89 specimens belonging to 10 mosquito species were selected for the extraction of proteins from legs and for the establishment of a reference database. A blind test with 123 mosquitoes was performed to validate the MS method. Results showed that: (a) the spectra obtained in the study with a given species differed from the spectra of the same species collected in another country, which highlights the need for an international database; (b) MALDI-TOF MS is an accurate method for the rapid identification of mosquito species that are referenced in a database; (c) MALDI-TOF MS allows the separation of groups or complex species, and (d) laboratory specimens undergo a loss of proteins compared with those isolated in the field. In conclusion, MALDI-TOF MS is a useful supplementary tool for mosquito identification and can help inform vector control. © 2017 The Royal Entomological Society.
O'Reilly, Christian; Gosselin, Nadia; Carrier, Julie; Nielsen, Tore
2014-12-01
Manual processing of sleep recordings is extremely time-consuming. Efforts to automate this process have shown promising results, but automatic systems are generally evaluated on private databases, not allowing accurate cross-validation with other systems. In lacking a common benchmark, the relative performances of different systems are not compared easily and advances are compromised. To address this fundamental methodological impediment to sleep study, we propose an open-access database of polysomnographic biosignals. To build this database, whole-night recordings from 200 participants [97 males (aged 42.9 ± 19.8 years) and 103 females (aged 38.3 ± 18.9 years); age range: 18-76 years] were pooled from eight different research protocols performed in three different hospital-based sleep laboratories. All recordings feature a sampling frequency of 256 Hz and an electroencephalography (EEG) montage of 4-20 channels plus standard electro-oculography (EOG), electromyography (EMG), electrocardiography (ECG) and respiratory signals. Access to the database can be obtained through the Montreal Archive of Sleep Studies (MASS) website (http://www.ceams-carsm.ca/en/MASS), and requires only affiliation with a research institution and prior approval by the applicant's local ethical review board. Providing the research community with access to this free and open sleep database is expected to facilitate the development and cross-validation of sleep analysis automation systems. It is also expected that such a shared resource will be a catalyst for cross-centre collaborations on difficult topics such as improving inter-rater agreement on sleep stage scoring. © 2014 European Sleep Research Society.
He, Ying; Chang, Tsung C; Li, Haijing; Shi, Gongyi; Tang, Yi-Wei
2011-07-01
More than 20 species of Legionella have been identified in relation to human infections. Rapid detection and identification of Legionella isolates is clinically useful to differentiate between infection and contamination and to determine treatment regimens. We explored the use of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) Biotyper system (Bruker Daltonik GmbH, Bremen, Germany) for the identification of Legionella species. The MALDI MS spectra were generated and compared with the Biotyper database, which includes 25 Legionella strains covering 22 species and four Legionella pneumophila serogroups. A total of 83 blind-coded Legionella strains, consisting of 54 reference and 29 clinical strains, were analyzed in the study. Overall, the Biotyper system correctly identified 51 (61.4%) of all strains and isolates to the species level. For species included in the Biotyper database, the method identified 51 (86.4%) strains out of 59 Legionella strains to the correct species level, including 24 (100%) L. pneumophila and 27 (77.1%) non-L. pneumophila strains. The remaining 24 Legionella strains, belonging to species not covered by the Biotyper database, were either identified to the Legionella genus level or had no reliable identification. The Biotyper system produces constant and reproducible MALDI MS spectra for Legionella strains and can be used for rapid and accurate Legionella identification. More Legionella strains, especially the non-L. pneumophila strains, need to be included in the current Biotyper database to cover varieties of Legionella species and to increase identification accuracy.
Taverna, Constanza Giselle; Mazza, Mariana; Bueno, Nadia Soledad; Alvarez, Christian; Amigot, Susana; Andreani, Mariana; Azula, Natalia; Barrios, Rubén; Fernández, Norma; Fox, Barbara; Guelfand, Liliana; Maldonado, Ivana; Murisengo, Omar Alejandro; Relloso, Silvia; Vivot, Matias; Davel, Graciela
2018-05-11
Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has revolutionized the identification of microorganisms in clinical laboratories because it is rapid, relatively simple to use, accurate, and can be used for a wide number of microorganisms. Several studies have demonstrated the utility of this technique in the identification of yeasts; however, its performance is usually improved by the extension of the database. Here we developed an in-house database of 143 strains belonging to 42 yeast species in the MALDI Biotyper platform, and we validated the extended database with 388 regional strains and 15 reference strains belonging to 55 yeast species. We also performed an intra- and interlaboratory study to assess reproducibility and analyzed the use of the cutoff values of 1.700 and 2.000 to correctly identify at species level. The creation of an in-house database that extended the manufacturer's database was successful in view of no incorrect identification was introduced. The best performance was observed by using the extended database and a cutoff value of 1.700 with a sensitivity of .94 and specificity of .96. A reproducibility study showed utility to detect deviations and could be used for external quality control. The extended database was able to differentiate closely related species and it has potential in distinguishing the molecular genotypes of Cryptococcus neoformans and Cryptococcus gattii.
Besil, Natalia; Uclés, Samanta; Mezcúa, Milagros; Heinzen, Horacio; Fernández-Alba, Amadeo R
2015-08-01
Gas chromatography coupled to high resolution hybrid quadrupole time-of-flight mass spectrometry (GC-QTOF MS), operating in negative chemical ionization (NCI) mode and combining full scan with MSMS experiments using accurate mass analysis, has been explored for the automated determination of pesticide residues in fruit and vegetables. Seventy compounds were included in this approach where 50 % of them are not approved by the EU legislation. A global 76 % of the analytes could be identified at 1 μg kg(-1). Recovery studies were developed at three concentration levels (1, 5, and 10 μg kg(-1)). Seventy-seven percent of the detected pesticides at the lowest level yielded recoveries within the 70 %-120 % range, whereas 94 % could be quantified at 5 μg kg(-1), and the 100 % were determined at 10 μg kg(-1). Good repeatability, expressed as relative standard deviation (RSD <20 %), was obtained for all compounds. The main drawback of the method was the limited dynamic range that was observed for some analytes that can be overcome either diluting the sample or lowering the injection volume. A home-made database was developed and applied to an automatic accurate mass data processing. Measured mass accuracies of the generated ions were mainly less than 5 ppm for at least one diagnostic ion. When only one ion was obtained in the single-stage NCI-MS, a representative product ion from MSMS experiments was used as identification criterion. A total of 30 real samples were analyzed and 67 % of the samples were positive for 12 different pesticides in the range 1.0-1321.3 μg kg(-1).
López-Hernández, Y; Patiño-Rodríguez, O; García-Orta, S T; Pinos-Rodríguez, J M
2016-12-01
An adequate and effective tuberculosis (TB) diagnosis system has been identified by the World Health Organization as a priority in the fight against this disease. Over the years, several methods have been developed to identify the bacillus, but bacterial culture remains one of the most affordable methods for most countries. For rapid and accurate identification, however, it is more feasible to implement molecular techniques, taking advantage of the availability of public databases containing protein sequences. Mass spectrometry (MS) has become an interesting technique for the identification of TB. Here, we review some of the most widely employed methods for identifying Mycobacterium tuberculosis and present an update on MS applied for the identification of mycobacterial species. © 2016 The Society for Applied Microbiology.
Allen, Felicity; Pon, Allison; Greiner, Russ; Wishart, David
2016-08-02
We describe a tool, competitive fragmentation modeling for electron ionization (CFM-EI) that, given a chemical structure (e.g., in SMILES or InChI format), computationally predicts an electron ionization mass spectrum (EI-MS) (i.e., the type of mass spectrum commonly generated by gas chromatography mass spectrometry). The predicted spectra produced by this tool can be used for putative compound identification, complementing measured spectra in reference databases by expanding the range of compounds able to be considered when availability of measured spectra is limited. The tool extends CFM-ESI, a recently developed method for computational prediction of electrospray tandem mass spectra (ESI-MS/MS), but unlike CFM-ESI, CFM-EI can handle odd-electron ions and isotopes and incorporates an artificial neural network. Tests on EI-MS data from the NIST database demonstrate that CFM-EI is able to model fragmentation likelihoods in low-resolution EI-MS data, producing predicted spectra whose dot product scores are significantly better than full enumeration "bar-code" spectra. CFM-EI also outperformed previously reported results for MetFrag, MOLGEN-MS, and Mass Frontier on one compound identification task. It also outperformed MetFrag in a range of other compound identification tasks involving a much larger data set, containing both derivatized and nonderivatized compounds. While replicate EI-MS measurements of chemical standards are still a more accurate point of comparison, CFM-EI's predictions provide a much-needed alternative when no reference standard is available for measurement. CFM-EI is available at https://sourceforge.net/projects/cfm-id/ for download and http://cfmid.wishartlab.com as a web service.
Analysis of framelets for breast cancer diagnosis.
Thivya, K S; Sakthivel, P; Venkata Sai, P M
2016-01-01
Breast cancer is the second threatening tumor among the women. The effective way of reducing breast cancer is its early detection which helps to improve the diagnosing process. Digital mammography plays a significant role in mammogram screening at earlier stage of breast carcinoma. Even though, it is very difficult to find accurate abnormality in prevalent screening by radiologists. But the possibility of precise breast cancer screening is encouraged by predicting the accurate type of abnormality through Computer Aided Diagnosis (CAD) systems. The two most important indicators of breast malignancy are microcalcifications and masses. In this study, framelet transform, a multiresolutional analysis is investigated for the classification of the above mentioned two indicators. The statistical and co-occurrence features are extracted from the framelet decomposed mammograms with different resolution levels and support vector machine is employed for classification with k-fold cross validation. This system achieves 94.82% and 100% accuracy in normal/abnormal classification (stage I) and benign/malignant classification (stage II) of mass classification system and 98.57% and 100% for microcalcification system when using the MIAS database.
Fine-structure resolved rotational transitions and database for CN+H2 collisions
NASA Astrophysics Data System (ADS)
Burton, Hannah; Mysliwiec, Ryan; Forrey, Robert C.; Yang, B. H.; Stancil, P. C.; Balakrishnan, N.
2018-06-01
Cross sections and rate coefficients for CN+H2 collisions are calculated using the coupled states (CS) approximation. The calculations are benchmarked against more accurate close-coupling (CC) calculations for transitions between low-lying rotational states. Comparisons are made between the two formulations for collision energies greater than 10 cm-1. The CS approximation is used to construct a database which includes highly excited rotational states that are beyond the practical limitations of the CC method. The database includes fine-structure resolved rotational quenching transitions for v = 0 and j ≤ 40, where v and j are the vibrational and rotational quantum numbers of the initial state of the CN molecule. Rate coefficients are computed for both para-H2 and ortho-H2 colliders. The results are shown to be in good agreement with previous calculations, however, the rates are substantially different from mass-scaled CN+He rates that are often used in astrophysical models.
Zampieri, Dávila; Santos, Vanessa G; Braga, Patrícia A C; Ferreira, Christina R; Ballottin, Daniela; Tasic, Ljubica; Basso, Andréa C; Sanches, Bruno V; Pontes, José H F; da Silva, Bárbara Pereira; Garboggini, Fabiana Fantinatti; Eberlin, Marcos N; Tata, Alessandra
2013-09-01
Commercial cattle breeders produce their own herd offspring for the dairy and beef market using artificial insemination. The procedure involves sanitary risks associated with the collection and commercialization of the germplasm, and the in vitro production and transfer of the bovine embryos must be monitored by strict health surveillance. To avoid the spreading of infectious diseases, one must rely on using controlled and monitored germplasm, media, and reagents that are guaranteed free of pathogens. In this article, we investigated the use of a new mass spectrometric approach for fast and accurate identification of bacteria and fungi in bovine semen and in culture media employed in the embryo in vitro production process. The microorganisms isolated from samples obtained in a commercial bovine embryo IVP setting were identified in a few minutes by their conserved peptide/protein profile, obtained applying matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS), matched against a commercial database. The successful microorganisms MS identification has been confirmed by DNA amplification and sequencing. Therefore, the MS technique seems to offer a powerful tool for rapid and accurate microorganism identification in semen and culture media samples. Copyright © 2013 Elsevier Inc. All rights reserved.
The BDNYC database of low-mass stars, brown dwarfs, and planetary mass companions
NASA Astrophysics Data System (ADS)
Cruz, Kelle; Rodriguez, David; Filippazzo, Joseph; Gonzales, Eileen; Faherty, Jacqueline K.; Rice, Emily; BDNYC
2018-01-01
We present a web-interface to a database of low-mass stars, brown dwarfs, and planetary mass companions. Users can send SELECT SQL queries to the database, perform searches by coordinates or name, check the database inventory on specified objects, and even plot spectra interactively. The initial version of this database contains information for 198 objects and version 2 will contain over 1000 objects. The database currently includes photometric data from 2MASS, WISE, and Spitzer and version 2 will include a significant portion of the publicly available optical and NIR spectra for brown dwarfs. The database is maintained and curated by the BDNYC research group and we welcome contributions from other researchers via GitHub.
Suttisunhakul, Vichaya; Pumpuang, Apinya; Ekchariyawat, Peeraya; Wuthiekanun, Vanaporn; Elrod, Mindy G.; Turner, Paul; Currie, Bart J.; Phetsouvanh, Rattanaphone; Dance, David A. B.; Limmathurotsakul, Direk; Peacock, Sharon J.
2017-01-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is increasingly used for rapid bacterial identification. Studies of Burkholderia pseudomallei identification have involved small isolate numbers drawn from a restricted geographic region. There is a need to expand the reference database and evaluate B. pseudomallei from a wider geographic distribution that more fully captures the extensive genetic diversity of this species. Here, we describe the evaluation of over 650 isolates. Main spectral profiles (MSP) for 26 isolates of B. pseudomallei (N = 5) and other Burkholderia species (N = 21) were added to the Biotyper database. MALDI-TOF MS was then performed on 581 B. pseudomallei, 19 B. mallei, 6 B. thailandensis and 23 isolates representing a range of other bacterial species. B. pseudomallei originated from northeast and east Thailand (N = 524), Laos (N = 12), Cambodia (N = 14), Hong Kong (N = 4) and Australia (N = 27). All 581 B. pseudomallei were correctly identified, with 100% sensitivity and specificity. Accurate identification required a minimum inoculum of 5 x 107 CFU/ml, and identification could be performed on spiked blood cultures after 24 hours of incubation. Comparison between a dendrogram constructed from MALDI-TOF MS main spectrum profiles and a phylogenetic tree based on recA gene sequencing demonstrated that MALDI-TOF MS distinguished between B. pseudomallei and B. mallei, while the recA tree did not. MALDI-TOF MS is an accurate method for the identification of B. pseudomallei, and discriminates between this and other related Burkholderia species. PMID:28384252
Wide-range screening of psychoactive substances by FIA-HRMS: identification strategies.
Alechaga, Élida; Moyano, Encarnación; Galceran, Maria Teresa
2015-06-01
Recreational drugs (illicit drugs, human and veterinary medicines, legal highs, etc.) often contain lacing agents and adulterants which are not related to the main active ingredient. Serious side effects and even the death of the consumer have been related to the consumption of mixtures of psychoactive substances and/or adulterants, so it is important to know the actual composition of recreational drugs. In this work, a method based on flow injection analysis (FIA) coupled with high-resolution mass spectrometry (HRMS) is proposed for the fast identification of psychoactive substances in recreational drugs and legal highs. The FIA and HRMS working conditions were optimized in order to detect a wide range of psychoactive compounds. As most of the psychoactive substances are acid-base compounds, methanol-0.1 % aqueous formic acid (1:1 v/v) as a carrier solvent and electrospray in both positive ion mode and negative ion mode were used. Two data acquisition modes, full scan at high mass resolution (HRMS) and data-dependent tandem mass spectrometry (ddMS/HRMS) with a quadrupole-Orbitrap mass analyzer were used, resulting in sufficient selectivity for identification of the components of the samples. A custom-made database containing over 450 substances, including psychoactive compounds and common adulterants, was built to perform a high-throughput target and suspect screening. Moreover, online accurate mass databases and mass fragmenter software were used to identify unknowns. Some examples, selected among the analyzed samples of recreational drugs and legal highs using the FIA-HRMS(ddMS/HRMS) method developed, are discussed to illustrate the screening strategy used in this study. The results showed that many of the analyzed samples were adulterated, and in some cases the sample composition did not match that of the supposed marketed substance.
Alves, Gelio; Yu, Yi-Kuo
2016-09-01
There is a growing trend for biomedical researchers to extract evidence and draw conclusions from mass spectrometry based proteomics experiments, the cornerstone of which is peptide identification. Inaccurate assignments of peptide identification confidence thus may have far-reaching and adverse consequences. Although some peptide identification methods report accurate statistics, they have been limited to certain types of scoring function. The extreme value statistics based method, while more general in the scoring functions it allows, demands accurate parameter estimates and requires, at least in its original design, excessive computational resources. Improving the parameter estimate accuracy and reducing the computational cost for this method has two advantages: it provides another feasible route to accurate significance assessment, and it could provide reliable statistics for scoring functions yet to be developed. We have formulated and implemented an efficient algorithm for calculating the extreme value statistics for peptide identification applicable to various scoring functions, bypassing the need for searching large random databases. The source code, implemented in C ++ on a linux system, is available for download at ftp://ftp.ncbi.nlm.nih.gov/pub/qmbp/qmbp_ms/RAId/RAId_Linux_64Bit yyu@ncbi.nlm.nih.gov Supplementary data are available at Bioinformatics online. Published by Oxford University Press 2016. This work is written by US Government employees and is in the public domain in the US.
SwePep, a database designed for endogenous peptides and mass spectrometry.
Fälth, Maria; Sköld, Karl; Norrman, Mathias; Svensson, Marcus; Fenyö, David; Andren, Per E
2006-06-01
A new database, SwePep, specifically designed for endogenous peptides, has been constructed to significantly speed up the identification process from complex tissue samples utilizing mass spectrometry. In the identification process the experimental peptide masses are compared with the peptide masses stored in the database both with and without possible post-translational modifications. This intermediate identification step is fast and singles out peptides that are potential endogenous peptides and can later be confirmed with tandem mass spectrometry data. Successful applications of this methodology are presented. The SwePep database is a relational database developed using MySql and Java. The database contains 4180 annotated endogenous peptides from different tissues originating from 394 different species as well as 50 novel peptides from brain tissue identified in our laboratory. Information about the peptides, including mass, isoelectric point, sequence, and precursor protein, is also stored in the database. This new approach holds great potential for removing the bottleneck that occurs during the identification process in the field of peptidomics. The SwePep database is available to the public.
NASA Astrophysics Data System (ADS)
Collins, J.; Edwards, B. R.; Fredricks, H. F.; Van Mooy, B. A.
2016-02-01
The lipids of marine plankton encompass a diversity of biochemical functions and chemotaxonomic specificities that make them ideal molecular biomarkers in living biomass. While core, nonpolar lipids such as free fatty acids (FFA) have formed the basis for many biomarker studies in fresh biomass, methods that enable the simultaneous profiling of core lipids and intact polar lipids (IPL) have opened new avenues for characterization of environmental stressors. We demonstrate the application of a novel, rules-based lipidomics data analysis pipeline to putatively identify a broad range of intact polar lipids, intact oxidized lipids (ox-lipids) and oxylipins in accurate-mass HPLC-ESI-MS data. Using mass spectra from a lipid peroxidation experiment conducted under the natural, ultraviolet-enriched light field in West Antarctica, we use the pipeline to identify ox-lipid and oxylipin biomarkers that might serve as indicators of photooxidative stress in phytoplankton. The lipidomics pipeline derives much of its functionality from two boutique lipid-oxylipin databases, which together contain entries for more than 60,000 candidate lipid biomarkers. These databases and all scripts required by the pipeline will be publicly available online to other users.
The establishment and use of the point source catalog database of the 2MASS near infrared survey
NASA Astrophysics Data System (ADS)
Gao, Y. F.; Shan, H. G.; Cheng, D.
2003-02-01
The 2MASS near infrared survey project is introduced briefly. The 2MASS point sources catalog (2MASS PSC) database and the network query system are established by using the PHP Hypertext Preprocessor and MySQL database server. By using the system, one can not only query information of sources listed in the catalog, but also draw the plots related. Moreover, after the 2MASS data are diagnosed , some research fields which can be benefited from this database are suggested.
Recent Advances in Targeted and Untargeted Metabolomics by NMR and MS/NMR Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bingol, Kerem
Metabolomics has made significant progress in multiple fronts in the last 18 months. This minireview aimed to give an overview of these advancements in the light of their contribution to targeted and untargeted metabolomics. New computational approaches have emerged to overcome manual absolute quantitation step of metabolites in 1D 1H NMR spectra. This provides more consistency between inter-laboratory comparisons. Integration of 2D NMR metabolomics databases under a unified web server allowed very accurate identification of the metabolites that have been catalogued in these databases. For the remaining uncatalogued and unknown metabolites, new cheminformatics approaches have been developed by combining NMRmore » and mass spectrometry. These hybrid NMR/MS approaches accelerated the identification of unknowns in untargeted studies, and now they are allowing to profile ever larger number of metabolites in application studies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salumbides, E. J.; Khramov, A.; Wolf, A. L.
2008-11-28
Two distinct high-accuracy laboratory spectroscopic investigations of the H{sub 2} molecule are reported. Anchor lines in the EF{sup 1}{sigma}{sub g}{sup +}-X{sup 1}{sigma}{sub g}{sup +} system are calibrated by two-photon deep-UV Doppler-free spectroscopy, while independent Fourier-transform spectroscopic measurements are performed that yield accurate spacings in the B{sup 1}{sigma}{sub u}{sup +}-EF{sup 1}{sigma}{sub g}{sup +} and I{sup 1}{pi}{sub g}-C{sup 1}{pi}{sub u} systems. From combination differences accurate transition wavelengths for the B-X Lyman and the C-X Werner lines can be determined with accuracies better than {approx}5x10{sup -9}, representing a major improvement over existing values. This metrology provides a practically exact database to extract amore » possible variation of the proton-to-electron mass ratio based on H{sub 2} lines in high-redshift objects. Moreover, it forms a rationale for equipping a future class of telescopes, carrying 30-40 m dishes, with novel spectrometers of higher resolving powers.« less
Structure Elucidation of Unknown Metabolites in Metabolomics by Combined NMR and MS/MS Prediction
Boiteau, Rene M.; Hoyt, David W.; Nicora, Carrie D.; ...
2018-01-17
Here, we introduce a cheminformatics approach that combines highly selective and orthogonal structure elucidation parameters; accurate mass, MS/MS (MS 2), and NMR in a single analysis platform to accurately identify unknown metabolites in untargeted studies. The approach starts with an unknown LC-MS feature, and then combines the experimental MS/MS and NMR information of the unknown to effectively filter the false positive candidate structures based on their predicted MS/MS and NMR spectra. We demonstrate the approach on a model mixture and then we identify an uncatalogued secondary metabolite in Arabidopsis thaliana. The NMR/MS 2 approach is well suited for discovery ofmore » new metabolites in plant extracts, microbes, soils, dissolved organic matter, food extracts, biofuels, and biomedical samples, facilitating the identification of metabolites that are not present in experimental NMR and MS metabolomics databases.« less
Structure Elucidation of Unknown Metabolites in Metabolomics by Combined NMR and MS/MS Prediction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boiteau, Rene M.; Hoyt, David W.; Nicora, Carrie D.
Here, we introduce a cheminformatics approach that combines highly selective and orthogonal structure elucidation parameters; accurate mass, MS/MS (MS 2), and NMR in a single analysis platform to accurately identify unknown metabolites in untargeted studies. The approach starts with an unknown LC-MS feature, and then combines the experimental MS/MS and NMR information of the unknown to effectively filter the false positive candidate structures based on their predicted MS/MS and NMR spectra. We demonstrate the approach on a model mixture and then we identify an uncatalogued secondary metabolite in Arabidopsis thaliana. The NMR/MS 2 approach is well suited for discovery ofmore » new metabolites in plant extracts, microbes, soils, dissolved organic matter, food extracts, biofuels, and biomedical samples, facilitating the identification of metabolites that are not present in experimental NMR and MS metabolomics databases.« less
Structure Elucidation of Unknown Metabolites in Metabolomics by Combined NMR and MS/MS Prediction
Hoyt, David W.; Nicora, Carrie D.; Kinmonth-Schultz, Hannah A.; Ward, Joy K.
2018-01-01
We introduce a cheminformatics approach that combines highly selective and orthogonal structure elucidation parameters; accurate mass, MS/MS (MS2), and NMR into a single analysis platform to accurately identify unknown metabolites in untargeted studies. The approach starts with an unknown LC-MS feature, and then combines the experimental MS/MS and NMR information of the unknown to effectively filter out the false positive candidate structures based on their predicted MS/MS and NMR spectra. We demonstrate the approach on a model mixture, and then we identify an uncatalogued secondary metabolite in Arabidopsis thaliana. The NMR/MS2 approach is well suited to the discovery of new metabolites in plant extracts, microbes, soils, dissolved organic matter, food extracts, biofuels, and biomedical samples, facilitating the identification of metabolites that are not present in experimental NMR and MS metabolomics databases. PMID:29342073
msBiodat analysis tool, big data analysis for high-throughput experiments.
Muñoz-Torres, Pau M; Rokć, Filip; Belužic, Robert; Grbeša, Ivana; Vugrek, Oliver
2016-01-01
Mass spectrometry (MS) are a group of a high-throughput techniques used to increase knowledge about biomolecules. They produce a large amount of data which is presented as a list of hundreds or thousands of proteins. Filtering those data efficiently is the first step for extracting biologically relevant information. The filtering may increase interest by merging previous data with the data obtained from public databases, resulting in an accurate list of proteins which meet the predetermined conditions. In this article we present msBiodat Analysis Tool, a web-based application thought to approach proteomics to the big data analysis. With this tool, researchers can easily select the most relevant information from their MS experiments using an easy-to-use web interface. An interesting feature of msBiodat analysis tool is the possibility of selecting proteins by its annotation on Gene Ontology using its Gene Id, ensembl or UniProt codes. The msBiodat analysis tool is a web-based application that allows researchers with any programming experience to deal with efficient database querying advantages. Its versatility and user-friendly interface makes easy to perform fast and accurate data screening by using complex queries. Once the analysis is finished, the result is delivered by e-mail. msBiodat analysis tool is freely available at http://msbiodata.irb.hr.
GLS-Finder: A Platform for Fast Profiling of Glucosinolates in Brassica Vegetables.
Sun, Jianghao; Zhang, Mengliang; Chen, Pei
2016-06-01
Mass spectrometry combined with related tandem techniques has become the most popular method for plant secondary metabolite characterization. We introduce a new strategy based on in-database searching, mass fragmentation behavior study, formula predicting for fast profiling of glucosinolates, a class of important compounds in brassica vegetables. A MATLAB script-based expert system computer program, "GLS-Finder", was developed. It is capable of qualitative and semi-quantitative analyses of glucosinolates in samples using data generated by ultrahigh-performance liquid chromatography-high-resolution accurate mass with multi-stage mass fragmentation (UHPLC-HRAM/MS(n)). A suite of bioinformatic tools was integrated into the "GLS-Finder" to perform raw data deconvolution, peak alignment, glucosinolate putative assignments, semi-quantitation, and unsupervised principal component analysis (PCA). GLS-Finder was successfully applied to identify intact glucosinolates in 49 commonly consumed Brassica vegetable samples in the United States. It is believed that this work introduces a new way of fast data processing and interpretation for qualitative and quantitative analyses of glucosinolates, where great efficacy was improved in comparison to identification manually.
Guo, Kevin; Bamforth, Fiona; Li, Liang
2011-02-01
Metabolome analysis of human cerebrospinal fluid (CSF) is challenging because of low abundance of metabolites present in a small volume of sample. We describe and apply a sensitive isotope labeling LC-MS technique for qualitative analysis of the CSF metabolome. After a CSF sample is divided into two aliquots, they are labeled by (13)C-dansyl and (12)C-dansyl chloride, respectively. The differentially labeled aliquots are then mixed and subjected to LC-MS using Fourier-transform ion cyclotron resonance mass spectrometry (FTICR MS). Dansylation offers significant improvement in the performance of chromatography separation and detection sensitivity. Moreover, peaks detected in the mass spectra can be readily analyzed for ion pair recognition and database search based on accurate mass and/or retention time information. It is shown that about 14,000 features can be detected in a 25-min LC-FTICR MS run of a dansyl-labeled CSF sample, from which about 500 metabolites can be profiled. Results from four CSF samples are compared to gauge the detectability of metabolites by this method. About 261 metabolites are commonly detected in replicate runs of four samples. In total, 1132 unique metabolite ion pairs are detected and 347 pairs (31%) matched with at least one metabolite in the Human Metabolome Database. We also report a dansylation library of 220 standard compounds and, using this library, about 85 metabolites can be positively identified. Among them, 21 metabolites have never been reported to be associated with CSF. These results illustrate that the dansylation LC-FTICR MS method can be used to analyze the CSF metabolome in a more comprehensive manner. © American Society for Mass Spectrometry, 2011
An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Chaochao; Monroe, Matthew E.; Xu, Zhe
2015-12-26
Comprehensive MS analysis of peptidome, the intracellular and intercellular products of protein degradation, has the potential to provide novel insights on endogenous proteolytic processing and their utility in disease diagnosis and prognosis. Along with the advances in MS instrumentation, a plethora of proteomics data analysis tools have been applied for direct use in peptidomics; however an evaluation of the currently available informatics pipelines for peptidomics data analysis has yet to be reported. In this study, we set off by evaluating the results of several popular MS/MS database search engines including MS-GF+, SEQUEST and MS-Align+ for peptidomics data analysis, followed bymore » identification and label-free quantification using the well-established accurate mass and time (AMT) tag and newly developed informed quantification (IQ) approaches, both based on direct LC-MS analysis. Our result demonstrated that MS-GF+ outperformed both SEQUEST and MS-Align+ in identifying peptidome peptides. Using a database established from the MS-GF+ peptide identifications, both the AMT tag and IQ approaches provided significantly deeper peptidome coverage and less missing value for each individual data set than the MS/MS methods, while achieving robust label-free quantification. Besides having an excellent correlation with the AMT tag quantification results, IQ also provided slightly higher peptidome coverage than AMT. Taken together, we propose an optimal informatics pipeline combining MS-GF+ for initial database searching with IQ (or AMT) for identification and label-free quantification for high-throughput, comprehensive and quantitative peptidomics analysis.« less
NASA Astrophysics Data System (ADS)
Liu, S.; Wei, Y.; Post, W. M.; Cook, R. B.; Schaefer, K.; Thornton, M. M.
2013-05-01
The Unified North American Soil Map (UNASM) was developed to provide more accurate regional soil information for terrestrial biosphere modeling. The UNASM combines information from state-of-the-art US STATSGO2 and Soil Landscape of Canada (SLCs) databases. The area not covered by these datasets is filled by using the Harmonized World Soil Database version 1.21 (HWSD1.21). The UNASM contains maximum soil depth derived from the data source as well as seven soil attributes (including sand, silt, and clay content, gravel content, organic carbon content, pH, and bulk density) for the topsoil layer (0-30 cm) and the subsoil layer (30-100 cm), respectively, of the spatial resolution of 0.25 degrees in latitude and longitude. There are pronounced differences in the spatial distributions of soil properties and soil organic carbon between UNASM and HWSD, but the UNASM overall provides more detailed and higher-quality information particularly in Alaska and central Canada. To provide more accurate and up-to-date estimate of soil organic carbon stock in North America, we incorporated Northern Circumpolar Soil Carbon Database (NCSCD) into the UNASM. The estimate of total soil organic carbon mass in the upper 100 cm soil profile based on the improved UNASM is 365.96 Pg, of which 23.1% is under trees, 14.1% is in shrubland, and 4.6% is in grassland and cropland. This UNASM data will provide a resource for use in terrestrial ecosystem modeling both for input of soil characteristics and for benchmarking model output.
NASA Astrophysics Data System (ADS)
Liu, S.; Wei, Y.; Post, W. M.; Cook, R. B.; Schaefer, K.; Thornton, M. M.
2012-10-01
The Unified North American Soil Map (UNASM) was developed to provide more accurate regional soil information for terrestrial biosphere modeling. The UNASM combines information from state-of-the-art US STATSGO2 and Soil Landscape of Canada (SLCs) databases. The area not covered by these datasets is filled with the Harmonized World Soil Database version 1.1 (HWSD1.1). The UNASM contains maximum soil depth derived from the data source as well as seven soil attributes (including sand, silt, and clay content, gravel content, organic carbon content, pH, and bulk density) for the top soil layer (0-30 cm) and the sub soil layer (30-100 cm) respectively, of the spatial resolution of 0.25° in latitude and longitude. There are pronounced differences in the spatial distributions of soil properties and soil organic carbon between UNASM and HWSD, but the UNASM overall provides more detailed and higher-quality information particularly in Alaska and Central Canada. To provide more accurate and up-to-date estimate of soil organic carbon stock in North America, we incorporated Northern Circumpolar Soil Carbon Database (NCSCD) into the UNASM. The estimate of total soil organic carbon mass in the upper 100 cm soil profile based on the improved UNASM is 347.70 Pg, of which 24.7% is under trees, 14.2% is under shrubs, and 1.3% is under grasses and 3.8% under crops. This UNASM data will provide a resource for use in land surface and terrestrial biogeochemistry modeling both for input of soil characteristics and for benchmarking model output.
Libraries of Peptide Fragmentation Mass Spectra Database
National Institute of Standards and Technology Data Gateway
SRD 1C NIST Libraries of Peptide Fragmentation Mass Spectra Database (Web, free access) The purpose of the library is to provide peptide reference data for laboratories employing mass spectrometry-based proteomics methods for protein analysis. Mass spectral libraries identify these compounds in a more sensitive and robust manner than alternative methods. These databases are freely available for testing and development of new applications.
Park, Hae-Min; Park, Ju-Hyeong; Kim, Yoon-Woo; Kim, Kyoung-Jin; Jeong, Hee-Jin; Jang, Kyoung-Soon; Kim, Byung-Gee; Kim, Yun-Gon
2013-11-15
In recent years, the improvement of mass spectrometry-based glycomics techniques (i.e. highly sensitive, quantitative and high-throughput analytical tools) has enabled us to obtain a large dataset of glycans. Here we present a database named Xeno-glycomics database (XDB) that contains cell- or tissue-specific pig glycomes analyzed with mass spectrometry-based techniques, including a comprehensive pig glycan information on chemical structures, mass values, types and relative quantities. It was designed as a user-friendly web-based interface that allows users to query the database according to pig tissue/cell types or glycan masses. This database will contribute in providing qualitative and quantitative information on glycomes characterized from various pig cells/organs in xenotransplantation and might eventually provide new targets in the α1,3-galactosyltransferase gene-knock out pigs era. The database can be accessed on the web at http://bioinformatics.snu.ac.kr/xdb.
Shao, Zhecheng; Wyatt, Mark F; Stein, Bridget K; Brenton, A Gareth
2010-10-30
A method for the accurate mass measurement of negative radical ions by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) is described. This is an extension to our previously described method for the accurate mass measurement of positive radical ions (Griffiths NW, Wyatt MF, Kean SD, Graham AE, Stein BK, Brenton AG. Rapid Commun. Mass Spectrom. 2010; 24: 1629). The porphyrin standard reference materials (SRMs) developed for positive mode measurements cannot be observed in negative ion mode, so fullerene and fluorinated porphyrin compounds were identified as effective SRMs. The method is of immediate practical use for the accurate mass measurement of functionalised fullerenes, for which negative ion MALDI-TOFMS is the principal mass spectrometry characterisation technique. This was demonstrated by the accurate mass measurement of six functionalised C(60) compounds. Copyright © 2010 John Wiley & Sons, Ltd.
Steinmann, I C; Pflüger, V; Schaffner, F; Mathis, A; Kaufmann, C
2013-03-01
Matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) was evaluated for the rapid identification of ceratopogonid larvae. Optimal sample preparation as evaluated with laboratory-reared biting midges Culicoides nubeculosus was the homogenization of gut-less larvae in 10% formic acid, and analysis of 0.2 mg/ml crude protein homogenate mixed with SA matrix at a ratio of 1:1.5. Using 5 larvae each of 4 ceratopogonid species (C. nubeculosus, C. obsoletus, C. decor, and Dasyhelea sp.) and of 2 culicid species (Aedes aegypti, Ae. japonicus), biomarker mass sets between 27 and 33 masses were determined. In a validation study, 67 larvae belonging to the target species were correctly identified by automated database-based identification (91%) or manual full comparison (9%). Four specimens of non-target species did not yield identification. As anticipated for holometabolous insects, the biomarker mass sets of adults cannot be used for the identification of larvae, and vice versa, because they share only very few similar masses as shown for C. nubeculosus, C. obsoletus, and Ae. japonicus. Thus, protein profiling by MALDI-TOF as a quick, inexpensive and accurate alternative tool is applicable to identify insect larvae of vector species collected in the field.
Schrödl, Wieland; Heydel, Tilo; Schwartze, Volker U; Hoffmann, Kerstin; Grosse-Herrenthey, Anke; Walther, Grit; Alastruey-Izquierdo, Ana; Rodriguez-Tudela, Juan Luis; Olias, Philipp; Jacobsen, Ilse D; de Hoog, G Sybren; Voigt, Kerstin
2012-02-01
Zygomycetes of the order Mucorales can cause life-threatening infections in humans. These mucormycoses are emerging and associated with a rapid tissue destruction and high mortality. The resistance of Mucorales to antimycotic substances varies between and within clinically important genera such as Mucor, Rhizopus, and Lichtheimia. Thus, an accurate diagnosis before onset of antimycotic therapy is recommended. Matrix-assisted laser desorption ionization (MALDI)-time of flight (TOF) mass spectrometry (MS) is a potentially powerful tool to rapidly identify infectious agents on the species level. We investigated the potential of MALDI-TOF MS to differentiate Lichtheimia species, one of the most important agents of mucormycoses. Using the Bruker Daltonics FlexAnalysis (version 3.0) software package, a spectral database library with m/z ratios of 2,000 to 20,000 Da was created for 19 type and reference strains of clinically relevant Zygomycetes of the order Mucorales (12 species in 7 genera). The database was tested for accuracy by use of 34 clinical and environmental isolates of Lichtheimia comprising a total of five species. Our data demonstrate that MALDI-TOF MS can be used to clearly discriminate Lichtheimia species from other pathogenic species of the Mucorales. Furthermore, the method is suitable to discriminate species within the genus. The reliability and robustness of the MALDI-TOF-based identification are evidenced by high score values (above 2.3) for the designation to a certain species and by moderate score values (below 2.0) for the discrimination between clinically relevant (Lichtheimia corymbifera, L. ramosa, and L. ornata) and irrelevant (L. hyalospora and L. sphaerocystis) species. In total, all 34 strains were unequivocally identified by MALDI-TOF MS with score values of >1.8 down to the generic level, 32 out of 34 of the Lichtheimia isolates (except CNM-CM 5399 and FSU 10566) were identified accurately with score values of >2 (probable species identification), and 25 of 34 isolates were identified to the species level with score values of >2.3 (highly probable species identification). The MALDI-TOF MS-based method reported here was found to be reproducible and accurate, with low consumable costs and minimal preparation time.
78 FR 60861 - Native American Tribal Insignia Database
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... Database ACTION: Proposed collection; comment request. SUMMARY: The United States Patent and Trademark... the report was that the USPTO create and maintain an accurate and comprehensive database containing... this recommendation, the Senate Committee on Appropriations directed the USPTO to create this database...
Remote Sensing Estimates of Glacier Mass Balance Changes in the Himalayas of Nepal
NASA Astrophysics Data System (ADS)
Ambinakudige, S.; Joshi, K.
2011-12-01
Mass balance changes of glaciers are important indicators of climate change. There are only 30 'reference' glaciers in the world that have continuous mass balance data with world glacier monitoring service since 1976. Especially, Himalayan glaciers are conspicuously absent from global mass balance records. This shows the urgent need for mass balance data for glaciers throughout the world. In this study, we estimated mass balance of some major glaciers in the Sagarmatha National Park (SNP) in Nepal using remote sensing applications. The SNP is one of the densest glaciated regions in the Himalayan range consisting approximately 296 glacial lakes. The region has experienced several glacial lake outburst floods (GLOFs) in recent years, causing extensive damage to local infrastructure and loss of human life. In general, mass balance is determined at seasonal or yearly intervals. Because of the rugged and difficult terrain of the Himalayan region, there are only a few field based measurements of mass balance available. Moreover, there are only few cases where the applications of remote sensing methods were used to calculate mass balance of the Himalayan glaciers due to the lack of accurate elevation data. Studies have shown that estimations of mass balance using remote sensing applications were within the range of field-based mass balance measurements from the same period. This study used ASTER VNIR, 3N (nadir view) and 3B (backward view) bands to generate Digital Elevation Models (DEMs) for the SNP area. 3N and 3B bands generate an along track stereo pair with a base-to-height (B/H) ratio of about 0.6. Accurate measurement of ground control points (GCPs), their numbers and distribution are important inputs in creating accurate DEMs. Because of the availability of topographic maps for this area, we were able to provide very accurate GCPs, in sufficient numbers and distribution. We created DEMs for the years 2002, 2003, 2004 and 2005 using ENVI DEM extraction tool. Bands 3N and 3B were used as left and right images respectively in the process of creating the DEM. Minimum elevation in these images was 1500m and maximum elevation was 8550m. Coordinates and elevation values from topographic maps in the non-glaciated region were used as GCPs while creating absolute DEMs. Considering the high terrain of the study area, we used large number of GCPs, tie points, higher windows search area, and high terrain parameters to improve DEM accuracy. Since these images were acquired in September, the accumulation area was clearly visible. The Global land ice measurement (GLIMS) database which is maintained at the National Snow and Ice Data Center (NSIDC) was used to delineate glacier boundaries. The differences between the elevations in consecutive years in the accumulation area were calculated using raster calculator. The total elevation differences were then multiplied by the area to estimate the change in volume. Density of ice used in mass balance calculation was 900kg per sq. meters. The result indicated that while there was a decrease in mass balance of some glaciers, some showed an increase in mass balance during the study period. The study helped to develop a data on mass balance change in some major glaciers in the Himalayas.
78 FR 39290 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-01
... project, known as the ``National Mortgage Database,'' which is a joint effort of FHFA and the Consumer... a database of timely and otherwise unavailable residential mortgage market information to be made... Mortgage Database. The key purpose of the National Mortgage Database is to make accessible accurate...
A comprehensive and scalable database search system for metaproteomics.
Chatterjee, Sandip; Stupp, Gregory S; Park, Sung Kyu Robin; Ducom, Jean-Christophe; Yates, John R; Su, Andrew I; Wolan, Dennis W
2016-08-16
Mass spectrometry-based shotgun proteomics experiments rely on accurate matching of experimental spectra against a database of protein sequences. Existing computational analysis methods are limited in the size of their sequence databases, which severely restricts the proteomic sequencing depth and functional analysis of highly complex samples. The growing amount of public high-throughput sequencing data will only exacerbate this problem. We designed a broadly applicable metaproteomic analysis method (ComPIL) that addresses protein database size limitations. Our approach to overcome this significant limitation in metaproteomics was to design a scalable set of sequence databases assembled for optimal library querying speeds. ComPIL was integrated with a modified version of the search engine ProLuCID (termed "Blazmass") to permit rapid matching of experimental spectra. Proof-of-principle analysis of human HEK293 lysate with a ComPIL database derived from high-quality genomic libraries was able to detect nearly all of the same peptides as a search with a human database (~500x fewer peptides in the database), with a small reduction in sensitivity. We were also able to detect proteins from the adenovirus used to immortalize these cells. We applied our method to a set of healthy human gut microbiome proteomic samples and showed a substantial increase in the number of identified peptides and proteins compared to previous metaproteomic analyses, while retaining a high degree of protein identification accuracy and allowing for a more in-depth characterization of the functional landscape of the samples. The combination of ComPIL with Blazmass allows proteomic searches to be performed with database sizes much larger than previously possible. These large database searches can be applied to complex meta-samples with unknown composition or proteomic samples where unexpected proteins may be identified. The protein database, proteomic search engine, and the proteomic data files for the 5 microbiome samples characterized and discussed herein are open source and available for use and additional analysis.
SimPhospho: a software tool enabling confident phosphosite assignment.
Suni, Veronika; Suomi, Tomi; Tsubosaka, Tomoya; Imanishi, Susumu Y; Elo, Laura L; Corthals, Garry L
2018-03-27
Mass spectrometry combined with enrichment strategies for phosphorylated peptides has been successfully employed for two decades to identify sites of phosphorylation. However, unambiguous phosphosite assignment is considered challenging. Given that site-specific phosphorylation events function as different molecular switches, validation of phosphorylation sites is of utmost importance. In our earlier study we developed a method based on simulated phosphopeptide spectral libraries, which enables highly sensitive and accurate phosphosite assignments. To promote more widespread use of this method, we here introduce a software implementation with improved usability and performance. We present SimPhospho, a fast and user-friendly tool for accurate simulation of phosphopeptide tandem mass spectra. Simulated phosphopeptide spectral libraries are used to validate and supplement database search results, with a goal to improve reliable phosphoproteome identification and reporting. The presented program can be easily used together with the Trans-Proteomic Pipeline and integrated in a phosphoproteomics data analysis workflow. SimPhospho is available for Windows, Linux and Mac operating systems at https://sourceforge.net/projects/simphospho/. It is open source and implemented in C ++. A user's manual with detailed description of data analysis using SimPhospho as well as test data can be found as supplementary material of this article. Supplementary data are available at https://www.btk.fi/research/ computational-biomedicine/software/.
Identification of bacteria isolated from veterinary clinical specimens using MALDI-TOF MS.
Pavlovic, Melanie; Wudy, Corinna; Zeller-Peronnet, Veronique; Maggipinto, Marzena; Zimmermann, Pia; Straubinger, Alix; Iwobi, Azuka; Märtlbauer, Erwin; Busch, Ulrich; Huber, Ingrid
2015-01-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has recently emerged as a rapid and accurate identification method for bacterial species. Although it has been successfully applied for the identification of human pathogens, it has so far not been well evaluated for routine identification of veterinary bacterial isolates. This study was performed to compare and evaluate the performance of MALDI-TOF MS based identification of veterinary bacterial isolates with commercially available conventional test systems. Discrepancies of both methods were resolved by sequencing 16S rDNA and, if necessary, the infB gene for Actinobacillus isolates. A total of 375 consecutively isolated veterinary samples were collected. Among the 357 isolates (95.2%) correctly identified at the genus level by MALDI-TOF MS, 338 of them (90.1% of the total isolates) were also correctly identified at the species level. Conventional methods offered correct species identification for 319 isolates (85.1%). MALDI-TOF identification therefore offered more accurate identification of veterinary bacterial isolates. An update of the in-house mass spectra database with additional reference spectra clearly improved the identification results. In conclusion, the presented data suggest that MALDI-TOF MS is an appropriate platform for classification and identification of veterinary bacterial isolates.
Juin, Camille; Bonnet, Antoine; Nicolau, Elodie; Bérard, Jean-Baptiste; Devillers, Romain; Thiéry, Valérie; Cadoret, Jean-Paul; Picot, Laurent
2015-01-01
A fast and high-resolution UPLC-MSE analysis was used to identify phytoplankton pigments in an ethanol extract of Porphyridium purpureum (Pp) devoid of phycobiliproteins. In a first step, 22 standard pigments were analyzed by UPLC-MSE to build a database including retention time and accurate masses of parent and fragment ions. Using this database, seven pigments or derivatives previously reported in Pp were unequivocally identified: β,β-carotene, chlorophyll a, zeaxanthin, chlorophyllide a, pheophorbide a, pheophytin a, and cryptoxanthin. Minor amounts of Divinyl chlorophyll a, a chemotaxonomic pigment marker for prochlorophytes, were also unequivocally identified using the database. Additional analysis of ionization and fragmentation patterns indicated the presence of ions that could correspond to hydroxylated derivatives of chlorophyll a and pheophytin a, produced during the ethanolic extraction, as well as previously described galactosyldiacylglycerols, the thylakoid coenzyme plastoquinone, and gracilamide B, a molecule previously reported in the red seaweed Gracillaria asiatica. These data point to UPLC-MSE as an efficient technique to identify phytoplankton pigments for which standards are available, and demonstrate its major interest as a complementary method for the structural elucidation of ionizable marine molecules. PMID:25913708
NASA Astrophysics Data System (ADS)
Guo, Kevin; Bamforth, Fiona; Li, Liang
2011-02-01
Metabolome analysis of human cerebrospinal fluid (CSF) is challenging because of low abundance of metabolites present in a small volume of sample. We describe and apply a sensitive isotope labeling LC-MS technique for qualitative analysis of the CSF metabolome. After a CSF sample is divided into two aliquots, they are labeled by 13C-dansyl and 12C-dansyl chloride, respectively. The differentially labeled aliquots are then mixed and subjected to LC-MS using Fourier-transform ion cyclotron resonance mass spectrometry (FTICR MS). Dansylation offers significant improvement in the performance of chromatography separation and detection sensitivity. Moreover, peaks detected in the mass spectra can be readily analyzed for ion pair recognition and database search based on accurate mass and/or retention time information. It is shown that about 14,000 features can be detected in a 25-min LC-FTICR MS run of a dansyl-labeled CSF sample, from which about 500 metabolites can be profiled. Results from four CSF samples are compared to gauge the detectability of metabolites by this method. About 261 metabolites are commonly detected in replicate runs of four samples. In total, 1132 unique metabolite ion pairs are detected and 347 pairs (31%) matched with at least one metabolite in the Human Metabolome Database. We also report a dansylation library of 220 standard compounds and, using this library, about 85 metabolites can be positively identified. Among them, 21 metabolites have never been reported to be associated with CSF. These results illustrate that the dansylation LC-FTICR MS method can be used to analyze the CSF metabolome in a more comprehensive manner.
Becker, Pierre T; de Bel, Annelies; Martiny, Delphine; Ranque, Stéphane; Piarroux, Renaud; Cassagne, Carole; Detandt, Monique; Hendrickx, Marijke
2014-11-01
The identification of filamentous fungi by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) relies mainly on a robust and extensive database of reference spectra. To this end, a large in-house library containing 760 strains and representing 472 species was built and evaluated on 390 clinical isolates by comparing MALDI-TOF MS with the classical identification method based on morphological observations. The use of MALDI-TOF MS resulted in the correct identification of 95.4% of the isolates at species level, without considering LogScore values. Taking into account the Brukers' cutoff value for reliability (LogScore >1.70), 85.6% of the isolates were correctly identified. For a number of isolates, microscopic identification was limited to the genus, resulting in only 61.5% of the isolates correctly identified at species level while the correctness reached 94.6% at genus level. Using this extended in-house database, MALDI-TOF MS thus appears superior to morphology in order to obtain a robust and accurate identification of filamentous fungi. A continuous extension of the library is however necessary to further improve its reliability. Indeed, 15 isolates were still not represented while an additional three isolates were not recognized, probably because of a lack of intraspecific variability of the corresponding species in the database. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Approximating the near-edge mass absorption coefficients for Ni using an ultra-thin bimetal foil
Alkire, Randall W.
2016-11-01
In an effort to improve the characteristics of a fluorescing metal-foil-based beam position monitor, a new bimetal ultra-thin (0.98/0.67 µm) Ti–Ni foil was introduced to replace an existing single-element ultra-thin 0.5 µm thick Cr foil. During characterization it was determined that absorption measurements on the bimetal foil could be used to fit the Ni mass absorption coefficients accurately in the vicinity of the NiKedge. Comparison with experimental results from the literature demonstrated that the fitting procedure produced coefficients with uncertainties of the order of ±1%. Once determined, these fit coefficients allowed the thickness of an independently mounted 8 µm thickmore » Ni foil to be computed from absorption measurements instead of relying on a tool-based measurement of the foil thickness. Using the 8 µm thick foil, a continuous map of Ni mass absorption coefficients was produced at 1 eV resolution throughout the near-edge region. Lastly, this high-resolution map marks a significant improvement over the existing NIST XCOM or FFAST database mass absorption coefficients, which have estimated errors of 10–20% for the near-edge region.« less
Achieving high confidence protein annotations in a sea of unknowns
NASA Astrophysics Data System (ADS)
Timmins-Schiffman, E.; May, D. H.; Noble, W. S.; Nunn, B. L.; Mikan, M.; Harvey, H. R.
2016-02-01
Increased sensitivity of mass spectrometry (MS) technology allows deep and broad insight into community functional analyses. Metaproteomics holds the promise to reveal functional responses of natural microbial communities, whereas metagenomics alone can only hint at potential functions. The complex datasets resulting from ocean MS have the potential to inform diverse realms of the biological, chemical, and physical ocean sciences, yet the extent of bacterial functional diversity and redundancy has not been fully explored. To take advantage of these impressive datasets, we need a clear bioinformatics pipeline for metaproteomics peptide identification and annotation with a database that can provide confident identifications. Researchers must consider whether it is sufficient to leverage the vast quantities of available ocean sequence data or if they must invest in site-specific metagenomic sequencing. We have sequenced, to our knowledge, the first western arctic metagenomes from the Bering Strait and the Chukchi Sea. We have addressed the long standing question: Is a metagenome required to accurately complete metaproteomics and assess the biological distribution of metabolic functions controlling nutrient acquisition in the ocean? Two different protein databases were constructed from 1) a site-specific metagenome and 2) subarctic/arctic groups available in NCBI's non-redundant database. Multiple proteomic search strategies were employed, against each individual database and against both databases combined, to determine the algorithm and approach that yielded the balance of high sensitivity and confident identification. Results yielded over 8200 confidently identified proteins. Our comparison of these results allows us to quantify the utility of investing resources in a metagenome versus using the constantly expanding and immediately available public databases for metaproteomic studies.
Al-Masni, Mohammed A; Al-Antari, Mugahed A; Park, Jeong-Min; Gi, Geon; Kim, Tae-Yeon; Rivera, Patricio; Valarezo, Edwin; Choi, Mun-Taek; Han, Seung-Moo; Kim, Tae-Seong
2018-04-01
Automatic detection and classification of the masses in mammograms are still a big challenge and play a crucial role to assist radiologists for accurate diagnosis. In this paper, we propose a novel Computer-Aided Diagnosis (CAD) system based on one of the regional deep learning techniques, a ROI-based Convolutional Neural Network (CNN) which is called You Only Look Once (YOLO). Although most previous studies only deal with classification of masses, our proposed YOLO-based CAD system can handle detection and classification simultaneously in one framework. The proposed CAD system contains four main stages: preprocessing of mammograms, feature extraction utilizing deep convolutional networks, mass detection with confidence, and finally mass classification using Fully Connected Neural Networks (FC-NNs). In this study, we utilized original 600 mammograms from Digital Database for Screening Mammography (DDSM) and their augmented mammograms of 2,400 with the information of the masses and their types in training and testing our CAD. The trained YOLO-based CAD system detects the masses and then classifies their types into benign or malignant. Our results with five-fold cross validation tests show that the proposed CAD system detects the mass location with an overall accuracy of 99.7%. The system also distinguishes between benign and malignant lesions with an overall accuracy of 97%. Our proposed system even works on some challenging breast cancer cases where the masses exist over the pectoral muscles or dense regions. Copyright © 2018 Elsevier B.V. All rights reserved.
Choosing an Optimal Database for Protein Identification from Tandem Mass Spectrometry Data.
Kumar, Dhirendra; Yadav, Amit Kumar; Dash, Debasis
2017-01-01
Database searching is the preferred method for protein identification from digital spectra of mass to charge ratios (m/z) detected for protein samples through mass spectrometers. The search database is one of the major influencing factors in discovering proteins present in the sample and thus in deriving biological conclusions. In most cases the choice of search database is arbitrary. Here we describe common search databases used in proteomic studies and their impact on final list of identified proteins. We also elaborate upon factors like composition and size of the search database that can influence the protein identification process. In conclusion, we suggest that choice of the database depends on the type of inferences to be derived from proteomics data. However, making additional efforts to build a compact and concise database for a targeted question should generally be rewarding in achieving confident protein identifications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Shishi; Wei, Yaxing; Post, Wilfred M
2013-01-01
The Unified North American Soil Map (UNASM) was developed to provide more accurate regional soil information for terrestrial biosphere modeling. The UNASM combines information from state-of-the-art U.S. STATSGO2 and Soil Landscape of Canada (SLCs) databases. The area not covered by these datasets is filled with the Harmonized World Soil Database version 1.1 (HWSD1.1). The UNASM contains maximum soil depth derived from the data source as well as seven soil attributes (including sand, silt, and clay content, gravel content, organic carbon content, pH, and bulk density) for the top soil layer (0-30 cm) and the sub soil layer (30-100 cm) respectively,more » of the spatial resolution of 0.25 degrees in latitude and longitude. There are pronounced differences in the spatial distributions of soil properties and soil organic carbon between UNASM and HWSD, but the UNASM overall provides more detailed and higher-quality information particularly in Alaska and central Canada. To provide more accurate and up-to-date estimate of soil organic carbon stock in North America, we incorporated Northern Circumpolar Soil Carbon Database (NCSCD) into the UNASM. The estimate of total soil organic carbon mass in the upper 100 cm soil profile based on the improved UNASM is 347.70 Pg, of which 24.7% is under trees, 14.2% is under shrubs, and 1.3% is under grasses and 3.8% under crops. This UNASM data will provide a resource for use in land surface and terrestrial biogeochemistry modeling both for input of soil characteristics and for benchmarking model output.« less
NASA Astrophysics Data System (ADS)
Wei, Y.; Liu, S.; Huntzinger, D. N.; Michalak, A. M.; Post, W. M.; Cook, R. B.; Schaefer, K. M.; Thornton, M.
2014-12-01
The Unified North American Soil Map (UNASM) was developed by Multi-scale Synthesis and Terrestrial Model Intercomparison Project (MsTMIP) to provide more accurate regional soil information for terrestrial biosphere modeling. The UNASM combines information from state-of-the-art US STATSGO2 and Soil Landscape of Canada (SLCs) databases. The area not covered by these datasets is filled by using the Harmonized World Soil Database version 1.21 (HWSD1.21). The UNASM contains maximum soil depth derived from the data source as well as seven soil attributes (including sand, silt, and clay content, gravel content, organic carbon content, pH, and bulk density) for the topsoil layer (0-30 cm) and the subsoil layer (30-100 cm), respectively, of the spatial resolution of 0.25 degrees in latitude and longitude. There are pronounced differences in the spatial distributions of soil properties and soil organic carbon between UNASM and HWSD, but the UNASM overall provides more detailed and higher-quality information particularly in Alaska and central Canada. To provide more accurate and up-to-date estimate of soil organic carbon stock in North America, we incorporated Northern Circumpolar Soil Carbon Database (NCSCD) into the UNASM. The estimate of total soil organic carbon mass in the upper 100 cm soil profile based on the improved UNASM is 365.96 Pg, of which 23.1% is under trees, 14.1% is in shrubland, and 4.6% is in grassland and cropland. This UNASM data has been provided as a resource for use in terrestrial ecosystem modeling of MsTMIP both for input of soil characteristics and for benchmarking model output.
Accurate mass measurement: terminology and treatment of data.
Brenton, A Gareth; Godfrey, A Ruth
2010-11-01
High-resolution mass spectrometry has become ever more accessible with improvements in instrumentation, such as modern FT-ICR and Orbitrap mass spectrometers. This has resulted in an increase in the number of articles submitted for publication quoting accurate mass data. There is a plethora of terms related to accurate mass analysis that are in current usage, many employed incorrectly or inconsistently. This article is based on a set of notes prepared by the authors for research students and staff in our laboratories as a guide to the correct terminology and basic statistical procedures to apply in relation to mass measurement, particularly for accurate mass measurement. It elaborates on the editorial by Gross in 1994 regarding the use of accurate masses for structure confirmation. We have presented and defined the main terms in use with reference to the International Union of Pure and Applied Chemistry (IUPAC) recommendations for nomenclature and symbolism for mass spectrometry. The correct use of statistics and treatment of data is illustrated as a guide to new and existing mass spectrometry users with a series of examples as well as statistical methods to compare different experimental methods and datasets. Copyright © 2010. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Sohn, S. Tony; Van Der Marel, Roeland P.; Deason, Alis J.; Bellini, Andrea; Besla, Gurtina; Watkins, Laura
2016-06-01
The globular cluster (GC) system of the Milky Way (MW) provides important information on the MW's present structure and past evolution. GCs in the halo are particularly useful tracers; because of their long dynamical timescales, their orbits retain imprints of their origin or accretion history. Full 3D motions are required to calculate past orbits. While most GCs have known line of sight velocities, accurate proper motion (PM) measurements are currently available for only a few halo GCs. Our goal is to create the first high-quality PM database for halo GCs. We have identified suitable 1st-epoch data in the HST Archive for 20 halo GCs at 10-100 kpc from the Galactic Center. We are in the process of obtaining the necessary 2nd-epoch data to determine absolute PMs of the target GCs through our HST program GO-14235. We will use the same advanced astrometric techniques that allowed us to measure the PMs of M31 and Leo I. Previous studies of the halo GC system based on e.g., stellar populations, metallicities, RR Lyrae properties, and structural properties have revealed a dichotomy between old and young halo GCs. This may reflect distinct formation scenarios (in situ vs. accreted). Orbit calculations based on our PMs will directly test this. The PMs will also yield the best handle yet on the velocity anisotropy profile of any tracer population in the halo. This will resolve the mass-anisotropy degeneracy to provide an improved estimate of the MW mass, which is at present poorly known. In summary, our project will deliver the first accurate PMs for halo GCs, and will significantly increase our understanding of the formation, evolution, and mass of the MW.
Sanchis, Yovana; Coscollà, Clara; Roca, Marta; Yusà, Vicent
2015-06-01
An analytical strategy including both the quantitative target analysis of 8 regulated primary aromatic amines (PAAs), as well as a comprehensive post-run target screening of 77 migrating substances, was developed for nylon utensils, using liquid chromatography-orbitrap-high resolution mass spectrometry (LC-HRMS) operating in full scan mode. The accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), and by alternating two acquisition events, ESI+ with and without fragmentation. The target method was validated after statistical optimization of the main ionization and fragmentation parameters. The quantitative method presented appropriate performance to be used in official monitoring with recoveries ranging from 78% to 112%, precision in terms of Relative Standard Deviation (RSD) was less than 15%, and the limits of quantification were between 2 and 2.5 µg kg(-1). For post-target screening, a customized theoretical database was built for food contact material migrants, including bisphenols, phthalates, and other amines. For identification purposes, accurate exact mass (<5 ppm) and some diagnostic ions including fragments were used. The strategy was applied to 10 real samples collected from different retailers in the Valencian Region (Spain) during 2014. Six out of eight target PAAs were detected in at least one sample in the target analysis. The most frequently detected compounds were 4,4'-methylenedianiline and aniline, with concentrations ranging from 2.4 to 19,715 µg kg(-1) and 2.5 to 283 µg kg(-1), respectively. Two phthalates were identified and confirmed in the post-run target screening analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Verheggen, Kenneth; Raeder, Helge; Berven, Frode S; Martens, Lennart; Barsnes, Harald; Vaudel, Marc
2017-09-13
Sequence database search engines are bioinformatics algorithms that identify peptides from tandem mass spectra using a reference protein sequence database. Two decades of development, notably driven by advances in mass spectrometry, have provided scientists with more than 30 published search engines, each with its own properties. In this review, we present the common paradigm behind the different implementations, and its limitations for modern mass spectrometry datasets. We also detail how the search engines attempt to alleviate these limitations, and provide an overview of the different software frameworks available to the researcher. Finally, we highlight alternative approaches for the identification of proteomic mass spectrometry datasets, either as a replacement for, or as a complement to, sequence database search engines. © 2017 Wiley Periodicals, Inc.
Lotz, Aurélie; Ferroni, Agnès; Beretti, Jean-Luc; Dauphin, Brunhilde; Carbonnelle, Etienne; Guet-Revillet, Hélène; Veziris, Nicolas; Heym, Béate; Jarlier, Vincent; Gaillard, Jean-Louis; Pierre-Audigier, Catherine; Frapy, Eric; Berche, Patrick; Nassif, Xavier; Bille, Emmanuelle
2010-01-01
Mycobacterial identification is based on several methods: conventional biochemical tests that require several weeks for accurate identification, and molecular tools that are now routinely used. However, these techniques are expensive and time-consuming. In this study, an alternative method was developed using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). This approach allows a characteristic mass spectral fingerprint to be obtained from whole inactivated mycobacterial cells. We engineered a strategy based on specific profiles in order to identify the most clinically relevant species of mycobacteria. To validate the mycobacterial database, a total of 311 strains belonging to 31 distinct species and 4 species complexes grown in Löwenstein-Jensen (LJ) and liquid (mycobacterium growth indicator tube [MGIT]) media were analyzed. No extraction step was required. Correct identifications were obtained for 97% of strains from LJ and 77% from MGIT media. No misidentification was noted. Our results, based on a very simple protocol, suggest that this system may represent a serious alternative for clinical laboratories to identify mycobacterial species. PMID:20943874
Díaz, Ramon; Pozo, Oscar J; Sancho, Juan V; Hernández, Félix
2014-08-15
In this work, hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) coupled to ultra high performance liquid chromatography (UHPLC) has been used for biomarkers identification for correct authentication of Valencia (Spain) oranges. Differentiation from foreign Argentinean, Brazilian and South African oranges has been carried out using XCMS application and multivariate analysis to UHPLC-(Q)TOF MS data acquired in both, positive and negative ionisation modes. Several markers have been found and corroborated by analysing two seasons samples. A seasonal independent marker was found and its structure elucidated using accurate mass data and MS(E) fragmentation spectrum information. Empirical formula was searched in Reaxys database applying sub-structure filtering from the fragments obtained. Three possible structures were found and citrusin D, a compound present in sweet oranges, has been identified as the most plausible as it fits better with the product ion scan performed for this compound. As a result of data obtained in this work, citrusin D is suggested as a potential marker to distinguish the geographic origin of oranges. Copyright © 2014 Elsevier Ltd. All rights reserved.
Martin, Billie-Jean; Chen, Guanmin; Graham, Michelle; Quan, Hude
2014-02-13
Obesity is a pervasive problem and a popular subject of academic assessment. The ability to take advantage of existing data, such as administrative databases, to study obesity is appealing. The objective of our study was to assess the validity of obesity coding in an administrative database and compare the association between obesity and outcomes in an administrative database versus registry. This study was conducted using a coronary catheterization registry and an administrative database (Discharge Abstract Database (DAD)). A Body Mass Index (BMI) ≥30 kg/m2 within the registry defined obesity. In the DAD obesity was defined by diagnosis codes E65-E68 (ICD-10). The sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of an obesity diagnosis in the DAD was determined using obesity diagnosis in the registry as the referent. The association between obesity and outcomes was assessed. The study population of 17380 subjects was largely male (68.8%) with a mean BMI of 27.0 kg/m2. Obesity prevalence was lower in the DAD than registry (2.4% vs. 20.3%). A diagnosis of obesity in the DAD had a sensitivity 7.75%, specificity 98.98%, NPV 80.84% and PPV 65.94%. Obesity was associated with decreased risk of death or re-hospitalization, though non-significantly within the DAD. Obesity was significantly associated with an increased risk of cardiac procedure in both databases. Overall, obesity was poorly coded in the DAD. However, when coded, it was coded accurately. Administrative databases are not an optimal datasource for obesity prevalence and incidence surveillance but could be used to define obese cohorts for follow-up.
Specific identification of Bacillus anthracis strains
NASA Astrophysics Data System (ADS)
Krishnamurthy, Thaiya; Deshpande, Samir; Hewel, Johannes; Liu, Hongbin; Wick, Charles H.; Yates, John R., III
2007-01-01
Accurate identification of human pathogens is the initial vital step in treating the civilian terrorism victims and military personnel afflicted in biological threat situations. We have applied a powerful multi-dimensional protein identification technology (MudPIT) along with newly generated software termed Profiler to identify the sequences of specific proteins observed for few strains of Bacillus anthracis, a human pathogen. Software termed Profiler was created to initially screen the MudPIT data of B. anthracis strains and establish the observed proteins specific for its strains. A database was also generated using Profiler containing marker proteins of B. anthracis and its strains, which in turn could be used for detecting the organism and its corresponding strains in samples. Analysis of the unknowns by our methodology, combining MudPIT and Profiler, led to the accurate identification of the anthracis strains present in samples. Thus, a new approach for the identification of B. anthracis strains in unknown samples, based on the molecular mass and sequences of marker proteins, has been ascertained.
Lenobel, R; Sebela, M; Frébort, I
2005-01-01
The amino acid sequence of methylamine oxidase (MeAO) from the fungus Aspergillus niger was analyzed using mass spectrometry (MS). First, MeAO was characterized by an accurate molar mass of 72.4 kDa of the monomer measured using MALDI-TOF-MS and by a pI value of 5.8 determined by isoelectric focusing. MALDI-TOF-MS revealed a clear peptide mass fingerprint after tryptic digestion, which did not provide any relevant hit when searched against a nonredundant protein database and was different from that of A. niger amine oxidase AO-I. Tandem mass spectrometry with electrospray ionization coupled to liquid chromatography allowed unambiguous reading of six peptide sequences (11-19 amino acids) and seven sequence tags (4-15 amino acids), which were used for MS BLAST homology searching. MeAO was found to be largely homologous to a hypothetical protein AN7641.2 (EMBL/GenBank protein-accession code EAA61827) from Aspergillus nidulans FGSC A4 with a theoretical molar mass of 76.46 kDa and pI 6.14, which belongs to the superfamily of copper amine oxidases. The protein AN7641.2 is only little homologous to the amine oxidase AO-I (32% identity, 49 % similarity).
Knowns and unknowns in metabolomics identified by multidimensional NMR and hybrid MS/NMR methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bingol, Kerem; Brüschweiler, Rafael
Metabolomics continues to make rapid progress through the development of new and better methods and their applications to gain insight into the metabolism of a wide range of different biological systems from a systems biology perspective. Customization of NMR databases and search tools allows the faster and more accurate identification of known metabolites, whereas the identification of unknowns, without a need for extensive purification, requires new strategies to integrate NMR with mass spectrometry, cheminformatics, and computational methods. For some applications, the use of covalent and non-covalent attachments in the form of labeled tags or nanoparticles can significantly reduce the complexitymore » of these tasks.« less
A Web-based Tool for SDSS and 2MASS Database Searches
NASA Astrophysics Data System (ADS)
Hendrickson, M. A.; Uomoto, A.; Golimowski, D. A.
We have developed a web site using HTML, Php, Python, and MySQL that extracts, processes, and displays data from the Sloan Digital Sky Survey (SDSS) and the Two-Micron All-Sky Survey (2MASS). The goal is to locate brown dwarf candidates in the SDSS database by looking at color cuts; however, this site could also be useful for targeted searches of other databases as well. MySQL databases are created from broad searches of SDSS and 2MASS data. Broad queries on the SDSS and 2MASS database servers are run weekly so that observers have the most up-to-date information from which to select candidates for observation. Observers can look at detailed information about specific objects including finding charts, images, and available spectra. In addition, updates from previous observations can be added by any collaborators; this format makes observational collaboration simple. Observers can also restrict the database search, just before or during an observing run, to select objects of special interest.
Tandem Mass Spectrum Sequencing: An Alternative to Database Search Engines in Shotgun Proteomics.
Muth, Thilo; Rapp, Erdmann; Berven, Frode S; Barsnes, Harald; Vaudel, Marc
2016-01-01
Protein identification via database searches has become the gold standard in mass spectrometry based shotgun proteomics. However, as the quality of tandem mass spectra improves, direct mass spectrum sequencing gains interest as a database-independent alternative. In this chapter, the general principle of this so-called de novo sequencing is introduced along with pitfalls and challenges of the technique. The main tools available are presented with a focus on user friendly open source software which can be directly applied in everyday proteomic workflows.
Amick, G D
1999-01-01
A database containing names of mass spectral data files generated in a forensic toxicology laboratory and two Microsoft Visual Basic programs to maintain and search this database is described. The data files (approximately 0.5 KB/each) were collected from six mass spectrometers during routine casework. Data files were archived on 650 MB (74 min) recordable CD-ROMs. Each recordable CD-ROM was given a unique name, and its list of data file names was placed into the database. The present manuscript describes the use of search and maintenance programs for searching and routine upkeep of the database and creation of CD-ROMs for archiving of data files.
Identification of beer spoilage microorganisms using the MALDI Biotyper platform.
Turvey, Michelle Elizabeth; Weiland, Florian; Meneses, Jon; Sterenberg, Nick; Hoffmann, Peter
2016-03-01
Beer spoilage microorganisms present a major risk for the brewing industry and can lead to cost-intensive recall of contaminated products and damage to brand reputation. The applicability of molecular profiling using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) in combination with Biotyper software was investigated for the identification of beer spoilage microorganisms from routine brewery quality control samples. Reference mass spectrum profiles for three of the most common bacterial beer spoilage microorganisms (Lactobacillus lindneri, Lactobacillus brevis and Pediococcus damnosus), four commercially available brewing yeast strains (top- and bottom-fermenting) and Dekkera/Brettanomyces bruxellensis wild yeast were established, incorporated into the Biotyper reference library and validated by successful identification after inoculation into beer. Each bacterial species could be accurately identified and distinguished from one another and from over 5600 other microorganisms present in the Biotyper database. In addition, wild yeast contaminations were rapidly detected and distinguished from top- and bottom-fermenting brewing strains. The applicability and integration of mass spectrometry profiling using the Biotyper platform into existing brewery quality assurance practices within industry were assessed by analysing routine microbiology control samples from a local brewery, where contaminating microorganisms could be reliably identified. Brewery-isolated microorganisms not present in the Biotyper database were further analysed for identification using LC-MS/MS methods. This renders the Biotyper platform a promising candidate for biological quality control testing within the brewing industry as a more rapid, high-throughput and cost-effective technology that can be tailored for the detection of brewery-specific spoilage organisms from the local environment.
Causanilles, Ana; Kinyua, Juliet; Ruttkies, Christoph; van Nuijs, Alexander L N; Emke, Erik; Covaci, Adrian; de Voogt, Pim
2017-10-01
The inclusion of new psychoactive substances (NPS) in the wastewater-based epidemiology approach presents challenges, such as the reduced number of users that translates into low concentrations of residues and the limited pharmacokinetics information available, which renders the choice of target biomarker difficult. The sampling during special social settings, the analysis with improved analytical techniques, and data processing with specific workflow to narrow the search, are required approaches for a successful monitoring. This work presents the application of a qualitative screening technique to wastewater samples collected during a city festival, where likely users of recreational substances gather and consequently higher residual concentrations of used NPS are expected. The analysis was performed using liquid chromatography coupled to high-resolution mass spectrometry. Data were processed using an algorithm that involves the extraction of accurate masses (calculated based on molecular formula) of expected m/z from an in-house database containing about 2,000 entries, including NPS and transformation products. We positively identified eight NPS belonging to the classes of synthetic cathinones, phenethylamines and opioids. In addition, the presence of benzodiazepine analogues, classical drugs and other licit substances with potential for abuse was confirmed. The screening workflow based on a database search was useful in the identification of NPS biomarkers in wastewater. The findings highlight the specific classical drugs and low NPS use in the Netherlands. Additionally, meta-chlorophenylpiperazine (mCPP), 2,5-dimethoxy-4-bromophenethylamine (2C-B), and 4-fluoroamphetamine (FA) were identified in wastewater for the first time. Copyright © 2017 Elsevier Ltd. All rights reserved.
Clustering and Filtering Tandem Mass Spectra Acquired in Data-Independent Mode
NASA Astrophysics Data System (ADS)
Pak, Huisong; Nikitin, Frederic; Gluck, Florent; Lisacek, Frederique; Scherl, Alexander; Muller, Markus
2013-12-01
Data-independent mass spectrometry activates all ion species isolated within a given mass-to-charge window ( m/z) regardless of their abundance. This acquisition strategy overcomes the traditional data-dependent ion selection boosting data reproducibility and sensitivity. However, several tandem mass (MS/MS) spectra of the same precursor ion are acquired during chromatographic elution resulting in large data redundancy. Also, the significant number of chimeric spectra and the absence of accurate precursor ion masses hamper peptide identification. Here, we describe an algorithm to preprocess data-independent MS/MS spectra by filtering out noise peaks and clustering the spectra according to both the chromatographic elution profiles and the spectral similarity. In addition, we developed an approach to estimate the m/z value of precursor ions from clustered MS/MS spectra in order to improve database search performance. Data acquired using a small 3 m/z units precursor mass window and multiple injections to cover a m/z range of 400-1400 was processed with our algorithm. It showed an improvement in the number of both peptide and protein identifications by 8 % while reducing the number of submitted spectra by 18 % and the number of peaks by 55 %. We conclude that our clustering method is a valid approach for data analysis of these data-independent fragmentation spectra. The software including the source code is available for the scientific community.
Chang, Shu Fang; Yang, Rong Sen
2014-09-01
To examine the cut-off point of the osteoporosis self-assessment tool, age, weight and body mass index for osteoporosis among young adult Taiwanese women, using a large-scale health examination database containing bone mineral density tests. The cut-off points of osteoporosis risk factors identified earlier focus on menopausal or senior Caucasian and Asian women. However, young adult Asian women have seldom been identified. A retrospective historical cohort study. Using the 2009-2011 health examination database of a large-scale medical centre in northern Taiwan, this study investigated young adult Asian women (i.e. range in age from 30-49 years) in Taiwan who had received dual-energy X-ray absorptiometry test. This study also explored the cut-off point, sensitivity, specificity and diagnostic accuracy of receiver operating characteristics of osteoporosis among young adult females in Taiwan. This study collected 2454 young adult Asian women in Taiwan. Cochran-Armitage analysis results indicated that the prevalence of osteoporosis increased with decreasing weight, body mass index and osteoporosis self-assessment method quartiles. According to the results of receiver operating characteristics, weight, body mass index and osteoporosis self-assessment tool approaches can generally be used as indicators to predict osteoporosis among young adult Asian women. Results of this study demonstrate that Taiwanese women contracting osteoporosis tend to be young and underweight, as well as having a low body mass index and osteoporosis self-assessment scores. Those results further suggest that the assessment indicators for cut-off points are appropriately suitable for young adult women in Taiwan. Early detection is the only available means of preventing osteoporosis. Professional nurses should apply convenient and accurate assessment procedures to help young adult women to adopt preventive strategies against osteoporosis early, thus eliminating the probability of osteoporotic fracture. © 2013 John Wiley & Sons Ltd.
Ubukata, Masaaki; Jobst, Karl J; Reiner, Eric J; Reichenbach, Stephen E; Tao, Qingping; Hang, Jiliang; Wu, Zhanpin; Dane, A John; Cody, Robert B
2015-05-22
Comprehensive two-dimensional gas chromatography (GC×GC) and high-resolution mass spectrometry (HRMS) offer the best possible separation of their respective techniques. Recent commercialization of combined GC×GC-HRMS systems offers new possibilities for the analysis of complex mixtures. However, such experiments yield enormous data sets that require new informatics tools to facilitate the interpretation of the rich information content. This study reports on the analysis of dust obtained from an electronics recycling facility by using GC×GC in combination with a new high-resolution time-of-flight (TOF) mass spectrometer. New software tools for (non-traditional) Kendrick mass defect analysis were developed in this research and greatly aided in the identification of compounds containing chlorine and bromine, elements that feature in most persistent organic pollutants (POPs). In essence, the mass defect plot serves as a visual aid from which halogenated compounds are recognizable on the basis of their mass defect and isotope patterns. Mass chromatograms were generated based on specific ions identified in the plots as well as region of the plot predominantly occupied by halogenated contaminants. Tentative identification was aided by database searches, complementary electron-capture negative ionization experiments and elemental composition determinations from the exact mass data. These included known and emerging flame retardants, such as polybrominated diphenyl ethers (PBDEs), hexabromobenzene, tetrabromo bisphenol A and tris (1-chloro-2-propyl) phosphate (TCPP), as well as other legacy contaminants such as polychlorinated biphenyls (PCBs) and polychlorinated terphenyls (PCTs). Copyright © 2015 Elsevier B.V. All rights reserved.
Savige, Judy; Dagher, Hayat; Povey, Sue
2014-07-01
This study examined whether gene-specific DNA variant databases for inherited diseases of the kidney fulfilled the Human Variome Project recommendations of being complete, accurate, clinically relevant and freely available. A recent review identified 60 inherited renal diseases caused by mutations in 132 genes. The disease name, MIM number, gene name, together with "mutation" or "database," were used to identify web-based databases. Fifty-nine diseases (98%) due to mutations in 128 genes had a variant database. Altogether there were 349 databases (a median of 3 per gene, range 0-6), but no gene had two databases with the same number of variants, and 165 (50%) databases included fewer than 10 variants. About half the databases (180, 54%) had been updated in the previous year. Few (77, 23%) were curated by "experts" but these included nine of the 11 with the most variants. Even fewer databases (41, 12%) included clinical features apart from the name of the associated disease. Most (223, 67%) could be accessed without charge, including those for 50 genes (40%) with the maximum number of variants. Future efforts should focus on encouraging experts to collaborate on a single database for each gene affected in inherited renal disease, including both unpublished variants, and clinical phenotypes. © 2014 WILEY PERIODICALS, INC.
Database Search Engines: Paradigms, Challenges and Solutions.
Verheggen, Kenneth; Martens, Lennart; Berven, Frode S; Barsnes, Harald; Vaudel, Marc
2016-01-01
The first step in identifying proteins from mass spectrometry based shotgun proteomics data is to infer peptides from tandem mass spectra, a task generally achieved using database search engines. In this chapter, the basic principles of database search engines are introduced with a focus on open source software, and the use of database search engines is demonstrated using the freely available SearchGUI interface. This chapter also discusses how to tackle general issues related to sequence database searching and shows how to minimize their impact.
2013-01-01
Background A large-scale, highly accurate, machine-understandable drug-disease treatment relationship knowledge base is important for computational approaches to drug repurposing. The large body of published biomedical research articles and clinical case reports available on MEDLINE is a rich source of FDA-approved drug-disease indication as well as drug-repurposing knowledge that is crucial for applying FDA-approved drugs for new diseases. However, much of this information is buried in free text and not captured in any existing databases. The goal of this study is to extract a large number of accurate drug-disease treatment pairs from published literature. Results In this study, we developed a simple but highly accurate pattern-learning approach to extract treatment-specific drug-disease pairs from 20 million biomedical abstracts available on MEDLINE. We extracted a total of 34,305 unique drug-disease treatment pairs, the majority of which are not included in existing structured databases. Our algorithm achieved a precision of 0.904 and a recall of 0.131 in extracting all pairs, and a precision of 0.904 and a recall of 0.842 in extracting frequent pairs. In addition, we have shown that the extracted pairs strongly correlate with both drug target genes and therapeutic classes, therefore may have high potential in drug discovery. Conclusions We demonstrated that our simple pattern-learning relationship extraction algorithm is able to accurately extract many drug-disease pairs from the free text of biomedical literature that are not captured in structured databases. The large-scale, accurate, machine-understandable drug-disease treatment knowledge base that is resultant of our study, in combination with pairs from structured databases, will have high potential in computational drug repurposing tasks. PMID:23742147
Wang, Cheng; He, Lidong; Li, Da-Wei; Bruschweiler-Li, Lei; Marshall, Alan G; Brüschweiler, Rafael
2017-10-06
Metabolite identification in metabolomics samples is a key step that critically impacts downstream analysis. We recently introduced the SUMMIT NMR/mass spectrometry (MS) hybrid approach for the identification of the molecular structure of unknown metabolites based on the combination of NMR, MS, and combinatorial cheminformatics. Here, we demonstrate the feasibility of the approach for an untargeted analysis of both a model mixture and E. coli cell lysate based on 2D/3D NMR experiments in combination with Fourier transform ion cyclotron resonance MS and MS/MS data. For 19 of the 25 model metabolites, SUMMIT yielded complete structures that matched those in the mixture independent of database information. Of those, seven top-ranked structures matched those in the mixture, and four of those were further validated by positive ion MS/MS. For five metabolites, not part of the 19 metabolites, correct molecular structural motifs could be identified. For E. coli, SUMMIT MS/NMR identified 20 previously known metabolites with three or more 1 H spins independent of database information. Moreover, for 15 unknown metabolites, molecular structural fragments were determined consistent with their spin systems and chemical shifts. By providing structural information for entire metabolites or molecular fragments, SUMMIT MS/NMR greatly assists the targeted or untargeted analysis of complex mixtures of unknown compounds.
Chen, Xi; Cheng, Lei; Qu, Shichao; Huang, Daliang; Liu, Jiacheng; Cui, Han; Jia, Yanbo; Ji, Mingshan
2015-10-01
A method for rapid screening and confirmation of 205 pesticide residues in rice was developed by combining QuEChERS and high performance liquid chromatography-triple quadrupole-linear ion trap mass spectrometry (LC-Q-TRAP/MS). The rice samples were extracted with acetonitrile, and then cleaned up with primary secondary amine (PSA), anhydrous magnesium sulfate (MgSO4) and C18 adsorbent. Finally, the samples were detected by LC-Q-TRAP/MS in multiple reaction monitoring with information-dependent acquisition of enhanced product ion (MRM-IDA-EPI) mode followed with database searching. A total of 205 pesticide residues were confirmed by retention times, ion pairs and the database searching using EPI library, and quantified by external standard method. All the pesticides showed good linearities with linear correlation coefficients all above 0.995. The limits of quantification (LOQs) for the 205 pesticides were 0.5-10.0 μg/kg. The average recoveries of the 205 pesticides ranged from 62.4% to 127.1% with the relative standard deviations (RSDs) of 1.0% - 20.0% at spiked levels of 10 μg/kg and 50 μg/kg, and only 20 min were needed for the analysis of an actual rice sample. In brief, the method is fast, accurate and highly sensitive, and is suitable for the screening and confirmation of pesticide residues in rice.
MIDAS: a database-searching algorithm for metabolite identification in metabolomics.
Wang, Yingfeng; Kora, Guruprasad; Bowen, Benjamin P; Pan, Chongle
2014-10-07
A database searching approach can be used for metabolite identification in metabolomics by matching measured tandem mass spectra (MS/MS) against the predicted fragments of metabolites in a database. Here, we present the open-source MIDAS algorithm (Metabolite Identification via Database Searching). To evaluate a metabolite-spectrum match (MSM), MIDAS first enumerates possible fragments from a metabolite by systematic bond dissociation, then calculates the plausibility of the fragments based on their fragmentation pathways, and finally scores the MSM to assess how well the experimental MS/MS spectrum from collision-induced dissociation (CID) is explained by the metabolite's predicted CID MS/MS spectrum. MIDAS was designed to search high-resolution tandem mass spectra acquired on time-of-flight or Orbitrap mass spectrometer against a metabolite database in an automated and high-throughput manner. The accuracy of metabolite identification by MIDAS was benchmarked using four sets of standard tandem mass spectra from MassBank. On average, for 77% of original spectra and 84% of composite spectra, MIDAS correctly ranked the true compounds as the first MSMs out of all MetaCyc metabolites as decoys. MIDAS correctly identified 46% more original spectra and 59% more composite spectra at the first MSMs than an existing database-searching algorithm, MetFrag. MIDAS was showcased by searching a published real-world measurement of a metabolome from Synechococcus sp. PCC 7002 against the MetaCyc metabolite database. MIDAS identified many metabolites missed in the previous study. MIDAS identifications should be considered only as candidate metabolites, which need to be confirmed using standard compounds. To facilitate manual validation, MIDAS provides annotated spectra for MSMs and labels observed mass spectral peaks with predicted fragments. The database searching and manual validation can be performed online at http://midas.omicsbio.org.
MALDI-TOF MS as a tool to identify foodborne yeasts and yeast-like fungi.
Quintilla, Raquel; Kolecka, Anna; Casaregola, Serge; Daniel, Heide M; Houbraken, Jos; Kostrzewa, Markus; Boekhout, Teun; Groenewald, Marizeth
2018-02-02
Since food spoilage by yeasts causes high economic losses, fast and accurate identifications of yeasts associated with food and food-related products are important for the food industry. In this study the efficiency of the matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) to identify food related yeasts was evaluated. A CBS in-house MALDI-TOF MS database was created and later challenged with a blinded test set of 146 yeast strains obtained from food and food related products. Ninety eight percent of the strains were correctly identified with log score values>1.7. One strain, Mrakia frigida, gained a correct identification with a score value<1.7. Two strains could not be identified at first as they represented a mix of two different species. These mixes were Rhodotorula babjevae with Meyerozyma caribbica and Clavispora lusitaniae with Debaryomyces hansenii. After separation, all four species could be correctly identified with scores>1.7. Ambiguous identifications were observed due to two incorrect reference mass spectra's found in the commercial database BDAL v.4.0, namely Candida sake DSM 70763 which was re-identified as Candida oleophila, and Candida inconspicua DSM 70631 which was re-identified as Pichia membranifaciens. MALDI-TOF MS can distinguish between most of the species, but for some species complexes, such as the Kazachstania telluris and Mrakia frigida complexes, MALDI-TOF MS showed limited resolution and identification of sibling species was sometimes problematic. Despite this, we showed that the MALDI-TOF MS is applicable for routine identification and validation of foodborne yeasts, but a further update of the commercial reference databases is needed. Copyright © 2017 Elsevier B.V. All rights reserved.
De Carolis, E; Posteraro, B; Lass-Flörl, C; Vella, A; Florio, A R; Torelli, R; Girmenia, C; Colozza, C; Tortorano, A M; Sanguinetti, M; Fadda, G
2012-05-01
Accurate species discrimination of filamentous fungi is essential, because some species have specific antifungal susceptibility patterns, and misidentification may result in inappropriate therapy. We evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for species identification through direct surface analysis of the fungal culture. By use of culture collection strains representing 55 species of Aspergillus, Fusarium and Mucorales, a reference database was established for MALDI-TOF MS-based species identification according to the manufacturer's recommendations for microflex measurements and MALDI BioTyper 2.0 software. The profiles of young and mature colonies were analysed for each of the reference strains, and species-specific spectral fingerprints were obtained. To evaluate the database, 103 blind-coded fungal isolates collected in the routine clinical microbiology laboratory were tested. As a reference method for species designation, multilocus sequencing was used. Eighty-five isolates were unequivocally identified to the species level (≥99% sequence similarity); 18 isolates producing ambiguous results at this threshold were initially rated as identified to the genus level only. Further molecular analysis definitively assigned these isolates to the species Aspergillus oryzae (17 isolates) and Aspergillus flavus (one isolate), concordant with the MALDI-TOF MS results. Excluding nine isolates that belong to the fungal species not included in our reference database, 91 (96.8%) of 94 isolates were identified by MALDI-TOF MS to the species level, in agreement with the results of the reference method; three isolates were identified to the genus level. In conclusion, MALDI-TOF MS is suitable for the routine identification of filamentous fungi in a medical microbiology laboratory. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.
Mo, Fan; Hong, Xu; Gao, Feng; Du, Lin; Wang, Jun; Omenn, Gilbert S; Lin, Biaoyang
2008-12-16
Alternative splicing is an important gene regulation mechanism. It is estimated that about 74% of multi-exon human genes have alternative splicing. High throughput tandem (MS/MS) mass spectrometry provides valuable information for rapidly identifying potentially novel alternatively-spliced protein products from experimental datasets. However, the ability to identify alternative splicing events through tandem mass spectrometry depends on the database against which the spectra are searched. We wrote scripts in perl, Bioperl, mysql and Ensembl API and built a theoretical exon-exon junction protein database to account for all possible combinations of exons for a gene while keeping the frame of translation (i.e., keeping only in-phase exon-exon combinations) from the Ensembl Core Database. Using our liver cancer MS/MS dataset, we identified a total of 488 non-redundant peptides that represent putative exon skipping events. Our exon-exon junction database provides the scientific community with an efficient means to identify novel alternatively spliced (exon skipping) protein isoforms using mass spectrometry data. This database will be useful in annotating genome structures using rapidly accumulating proteomics data.
An Accessible Proteogenomics Informatics Resource for Cancer Researchers.
Chambers, Matthew C; Jagtap, Pratik D; Johnson, James E; McGowan, Thomas; Kumar, Praveen; Onsongo, Getiria; Guerrero, Candace R; Barsnes, Harald; Vaudel, Marc; Martens, Lennart; Grüning, Björn; Cooke, Ira R; Heydarian, Mohammad; Reddy, Karen L; Griffin, Timothy J
2017-11-01
Proteogenomics has emerged as a valuable approach in cancer research, which integrates genomic and transcriptomic data with mass spectrometry-based proteomics data to directly identify expressed, variant protein sequences that may have functional roles in cancer. This approach is computationally intensive, requiring integration of disparate software tools into sophisticated workflows, challenging its adoption by nonexpert, bench scientists. To address this need, we have developed an extensible, Galaxy-based resource aimed at providing more researchers access to, and training in, proteogenomic informatics. Our resource brings together software from several leading research groups to address two foundational aspects of proteogenomics: (i) generation of customized, annotated protein sequence databases from RNA-Seq data; and (ii) accurate matching of tandem mass spectrometry data to putative variants, followed by filtering to confirm their novelty. Directions for accessing software tools and workflows, along with instructional documentation, can be found at z.umn.edu/canresgithub. Cancer Res; 77(21); e43-46. ©2017 AACR . ©2017 American Association for Cancer Research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umar, Arzu; Kang, Hyuk; Timmermans, A. M.
2009-06-01
Tamoxifen-resistance is a major cause of death in patients with recurrent breast cancer. Current clinical factors can correctly predict therapy response in only half of the treated patients. Identification of proteins that associate with tamoxifen-resistance is a first step towards better response prediction and tailored treatment of patients. In the present study we intended to identify putative protein biomarkers indicative of tamoxifen therapy-resistance in breast cancer, using nanoLC coupled with FTICR MS. Comparative proteome analysis was performed on ~5,500 pooled tumor cells (corresponding to ~550 ng protein lysate/analysis) obtained through laser capture microdissection (LCM) from two independently processed data setsmore » (n=24 and n=27) containing both tamoxifen therapy-sensitive and therapy-resistant tumors. Peptides and proteins were identified by matching mass and elution time of newly acquired LC-MS features to information in previously generated accurate mass and time tag (AMT) reference databases.« less
Natsios, Georgios; Pastaka, Chaido; Vavougios, Georgios; Zarogiannis, Sotirios G; Tsolaki, Vasiliki; Dimoulis, Andreas; Seitanidis, Georgios; Gourgoulianis, Konstantinos I
2016-02-01
A growing body of evidence links obstructive sleep apnea (OSA) with hypertension. The authors performed a retrospective cohort study using the University Hospital of Larissa Sleep Apnea Database (1501 patients) to determine predictors of in-laboratory diagnosed OSA for development of hypertension. Differences in continuous variables were assessed via independent samples t test, whereas discrete variables were compared by Pearson's chi-square test. Multivariate analysis was performed via discriminant function analysis. There were several significant differences between hypertensive and normotensive patients. Age, body mass index, comorbidity, daytime oxygen saturation, and indices of hypoxia during sleep were deemed the most accurate predictors of hypertension, whereas apnea-hypopnea index and desaturation index were not. The single derived discriminant function was statistically significant (Wilk's lambda=0.771, χ(2) =289.070, P<.0001). Daytime and nocturnal hypoxia as consequences of chronic intermittent hypoxia play a central role in OSA-related hypertension and should be further evaluated as possible severity markers in OSA. ©2015 Wiley Periodicals, Inc.
Schrödl, Wieland; Heydel, Tilo; Schwartze, Volker U.; Hoffmann, Kerstin; Große-Herrenthey, Anke; Walther, Grit; Alastruey-Izquierdo, Ana; Rodriguez-Tudela, Juan Luis; Olias, Philipp; Jacobsen, Ilse D.; de Hoog, G. Sybren
2012-01-01
Zygomycetes of the order Mucorales can cause life-threatening infections in humans. These mucormycoses are emerging and associated with a rapid tissue destruction and high mortality. The resistance of Mucorales to antimycotic substances varies between and within clinically important genera such as Mucor, Rhizopus, and Lichtheimia. Thus, an accurate diagnosis before onset of antimycotic therapy is recommended. Matrix-assisted laser desorption ionization (MALDI)–time of flight (TOF) mass spectrometry (MS) is a potentially powerful tool to rapidly identify infectious agents on the species level. We investigated the potential of MALDI-TOF MS to differentiate Lichtheimia species, one of the most important agents of mucormycoses. Using the Bruker Daltonics FlexAnalysis (version 3.0) software package, a spectral database library with m/z ratios of 2,000 to 20,000 Da was created for 19 type and reference strains of clinically relevant Zygomycetes of the order Mucorales (12 species in 7 genera). The database was tested for accuracy by use of 34 clinical and environmental isolates of Lichtheimia comprising a total of five species. Our data demonstrate that MALDI-TOF MS can be used to clearly discriminate Lichtheimia species from other pathogenic species of the Mucorales. Furthermore, the method is suitable to discriminate species within the genus. The reliability and robustness of the MALDI-TOF-based identification are evidenced by high score values (above 2.3) for the designation to a certain species and by moderate score values (below 2.0) for the discrimination between clinically relevant (Lichtheimia corymbifera, L. ramosa, and L. ornata) and irrelevant (L. hyalospora and L. sphaerocystis) species. In total, all 34 strains were unequivocally identified by MALDI-TOF MS with score values of >1.8 down to the generic level, 32 out of 34 of the Lichtheimia isolates (except CNM-CM 5399 and FSU 10566) were identified accurately with score values of >2 (probable species identification), and 25 of 34 isolates were identified to the species level with score values of >2.3 (highly probable species identification). The MALDI-TOF MS-based method reported here was found to be reproducible and accurate, with low consumable costs and minimal preparation time. PMID:22135259
Zhang, Jiyang; Ma, Jie; Dou, Lei; Wu, Songfeng; Qian, Xiaohong; Xie, Hongwei; Zhu, Yunping; He, Fuchu
2009-02-01
The hybrid linear trap quadrupole Fourier-transform (LTQ-FT) ion cyclotron resonance mass spectrometer, an instrument with high accuracy and resolution, is widely used in the identification and quantification of peptides and proteins. However, time-dependent errors in the system may lead to deterioration of the accuracy of these instruments, negatively influencing the determination of the mass error tolerance (MET) in database searches. Here, a comprehensive discussion of LTQ/FT precursor ion mass error is provided. On the basis of an investigation of the mass error distribution, we propose an improved recalibration formula and introduce a new tool, FTDR (Fourier-transform data recalibration), that employs a graphic user interface (GUI) for automatic calibration. It was found that the calibration could adjust the mass error distribution to more closely approximate a normal distribution and reduce the standard deviation (SD). Consequently, we present a new strategy, LDSF (Large MET database search and small MET filtration), for database search MET specification and validation of database search results. As the name implies, a large-MET database search is conducted and the search results are then filtered using the statistical MET estimated from high-confidence results. By applying this strategy to a standard protein data set and a complex data set, we demonstrate the LDSF can significantly improve the sensitivity of the result validation procedure.
Development and applications of the EntomopathogenID MLSA database for use in agricultural systems
USDA-ARS?s Scientific Manuscript database
The current study reports the development and application of a publicly accessible, curated database of Hypocrealean entomopathogenic fungi sequence data. The goal was to provide a platform for users to easily access sequence data from reference strains. The database can be used to accurately identi...
Taoka, Masato; Yamauchi, Yoshio; Nobe, Yuko; Masaki, Shunpei; Nakayama, Hiroshi; Ishikawa, Hideaki; Takahashi, Nobuhiro; Isobe, Toshiaki
2009-11-01
We describe here a mass spectrometry (MS)-based analytical platform of RNA, which combines direct nano-flow reversed-phase liquid chromatography (RPLC) on a spray tip column and a high-resolution LTQ-Orbitrap mass spectrometer. Operating RPLC under a very low flow rate with volatile solvents and MS in the negative mode, we could estimate highly accurate mass values sufficient to predict the nucleotide composition of a approximately 21-nucleotide small interfering RNA, detect post-transcriptional modifications in yeast tRNA, and perform collision-induced dissociation/tandem MS-based structural analysis of nucleolytic fragments of RNA at a sub-femtomole level. Importantly, the method allowed the identification and chemical analysis of small RNAs in ribonucleoprotein (RNP) complex, such as the pre-spliceosomal RNP complex, which was pulled down from cultured cells with a tagged protein cofactor as bait. We have recently developed a unique genome-oriented database search engine, Ariadne, which allows tandem MS-based identification of RNAs in biological samples. Thus, the method presented here has broad potential for automated analysis of RNA; it complements conventional molecular biology-based techniques and is particularly suited for simultaneous analysis of the composition, structure, interaction, and dynamics of RNA and protein components in various cellular RNP complexes.
Contreras, María Del Mar; Bribi, Noureddine; Gómez-Caravaca, Ana María; Gálvez, Julio; Segura-Carretero, Antonio
2017-01-01
Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata . The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market.
Bribi, Noureddine; Gómez-Caravaca, Ana María
2017-01-01
Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata. The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market. PMID:29348751
Bristow, Tony; Constantine, Jill; Harrison, Mark; Cavoit, Fabien
2008-04-01
Orthogonal-acceleration quadrupole time-of-flight (oa-QTOF) mass spectrometers, employed for accurate mass measurement, have been commercially available for well over a decade. A limitation of the early instruments of this type was the narrow ion abundance range over which accurate mass measurements could be made with a high degree of certainty. Recently, a new generation of oa-QTOF mass spectrometers has been developed and these allow accurate mass measurements to be recorded over a much greater range of ion abundances. This development has resulted from new ion detection technology and improved electronic stability or by accurate control of the number of ions reaching the detector. In this report we describe the results from experiments performed to evaluate the mass measurement performance of the Bruker micrOTOF-Q, a member of the new-generation oa-QTOFs. The relationship between mass accuracy and ion abundance has been extensively evaluated and mass measurement accuracy remained stable (+/-1.5 m m/z units) over approximately 3-4 orders of magnitude of ion abundance. The second feature of the Bruker micrOTOF-Q that was evaluated was the SigmaFit function of the software. This isotope pattern-matching algorithm provides an exact numerical comparison of the theoretical and measured isotope patterns as an additional identification tool to accurate mass measurement. The smaller the value, the closer the match between theoretical and measured isotope patterns. This information is then employed to reduce the number of potential elemental formulae produced from the mass measurements. A relationship between the SigmaFit value and ion abundance has been established. The results from the study for both mass accuracy and SigmaFit were employed to define the performance criteria for the micrOTOF-Q. This provided increased confidence in the selection of elemental formulae resulting from accurate mass measurements.
Curation accuracy of model organism databases
Keseler, Ingrid M.; Skrzypek, Marek; Weerasinghe, Deepika; Chen, Albert Y.; Fulcher, Carol; Li, Gene-Wei; Lemmer, Kimberly C.; Mladinich, Katherine M.; Chow, Edmond D.; Sherlock, Gavin; Karp, Peter D.
2014-01-01
Manual extraction of information from the biomedical literature—or biocuration—is the central methodology used to construct many biological databases. For example, the UniProt protein database, the EcoCyc Escherichia coli database and the Candida Genome Database (CGD) are all based on biocuration. Biological databases are used extensively by life science researchers, as online encyclopedias, as aids in the interpretation of new experimental data and as golden standards for the development of new bioinformatics algorithms. Although manual curation has been assumed to be highly accurate, we are aware of only one previous study of biocuration accuracy. We assessed the accuracy of EcoCyc and CGD by manually selecting curated assertions within randomly chosen EcoCyc and CGD gene pages and by then validating that the data found in the referenced publications supported those assertions. A database assertion is considered to be in error if that assertion could not be found in the publication cited for that assertion. We identified 10 errors in the 633 facts that we validated across the two databases, for an overall error rate of 1.58%, and individual error rates of 1.82% for CGD and 1.40% for EcoCyc. These data suggest that manual curation of the experimental literature by Ph.D-level scientists is highly accurate. Database URL: http://ecocyc.org/, http://www.candidagenome.org// PMID:24923819
Integrated database for rapid mass movements in Norway
NASA Astrophysics Data System (ADS)
Jaedicke, C.; Lied, K.; Kronholm, K.
2009-03-01
Rapid gravitational slope mass movements include all kinds of short term relocation of geological material, snow or ice. Traditionally, information about such events is collected separately in different databases covering selected geographical regions and types of movement. In Norway the terrain is susceptible to all types of rapid gravitational slope mass movements ranging from single rocks hitting roads and houses to large snow avalanches and rock slides where entire mountainsides collapse into fjords creating flood waves and endangering large areas. In addition, quick clay slides occur in desalinated marine sediments in South Eastern and Mid Norway. For the authorities and inhabitants of endangered areas, the type of threat is of minor importance and mitigation measures have to consider several types of rapid mass movements simultaneously. An integrated national database for all types of rapid mass movements built around individual events has been established. Only three data entries are mandatory: time, location and type of movement. The remaining optional parameters enable recording of detailed information about the terrain, materials involved and damages caused. Pictures, movies and other documentation can be uploaded into the database. A web-based graphical user interface has been developed allowing new events to be entered, as well as editing and querying for all events. An integration of the database into a GIS system is currently under development. Datasets from various national sources like the road authorities and the Geological Survey of Norway were imported into the database. Today, the database contains 33 000 rapid mass movement events from the last five hundred years covering the entire country. A first analysis of the data shows that the most frequent type of recorded rapid mass movement is rock slides and snow avalanches followed by debris slides in third place. Most events are recorded in the steep fjord terrain of the Norwegian west coast, but major events are recorded all over the country. Snow avalanches account for most fatalities, while large rock slides causing flood waves and huge quick clay slides are the most damaging individual events in terms of damage to infrastructure and property and for causing multiple fatalities. The quality of the data is strongly influenced by the personal engagement of local observers and varying observation routines. This database is a unique source for statistical analysis including, risk analysis and the relation between rapid mass movements and climate. The database of rapid mass movement events will also facilitate validation of national hazard and risk maps.
Anomaly detection applied to a materials control and accounting database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whiteson, R.; Spanks, L.; Yarbro, T.
An important component of the national mission of reducing the nuclear danger includes accurate recording of the processing and transportation of nuclear materials. Nuclear material storage facilities, nuclear chemical processing plants, and nuclear fuel fabrication facilities collect and store large amounts of data describing transactions that involve nuclear materials. To maintain confidence in the integrity of these data, it is essential to identify anomalies in the databases. Anomalous data could indicate error, theft, or diversion of material. Yet, because of the complex and diverse nature of the data, analysis and evaluation are extremely tedious. This paper describes the authors workmore » in the development of analysis tools to automate the anomaly detection process for the Material Accountability and Safeguards System (MASS) that tracks and records the activities associated with accountable quantities of nuclear material at Los Alamos National Laboratory. Using existing guidelines that describe valid transactions, the authors have created an expert system that identifies transactions that do not conform to the guidelines. Thus, this expert system can be used to focus the attention of the expert or inspector directly on significant phenomena.« less
Wen, Bo; Xu, Shaohang; Sheynkman, Gloria M; Feng, Qiang; Lin, Liang; Wang, Quanhui; Xu, Xun; Wang, Jun; Liu, Siqi
2014-11-01
Single nucleotide variations (SNVs) located within a reading frame can result in single amino acid polymorphisms (SAPs), leading to alteration of the corresponding amino acid sequence as well as function of a protein. Accurate detection of SAPs is an important issue in proteomic analysis at the experimental and bioinformatic level. Herein, we present sapFinder, an R software package, for detection of the variant peptides based on tandem mass spectrometry (MS/MS)-based proteomics data. This package automates the construction of variation-associated databases from public SNV repositories or sample-specific next-generation sequencing (NGS) data and the identification of SAPs through database searching, post-processing and generation of HTML-based report with visualized interface. sapFinder is implemented as a Bioconductor package in R. The package and the vignette can be downloaded at http://bioconductor.org/packages/devel/bioc/html/sapFinder.html and are provided under a GPL-2 license. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Rhinoplasty perioperative database using a personal digital assistant.
Kotler, Howard S
2004-01-01
To construct a reliable, accurate, and easy-to-use handheld computer database that facilitates the point-of-care acquisition of perioperative text and image data specific to rhinoplasty. A user-modified database (Pendragon Forms [v.3.2]; Pendragon Software Corporation, Libertyville, Ill) and graphic image program (Tealpaint [v.4.87]; Tealpaint Software, San Rafael, Calif) were used to capture text and image data, respectively, on a Palm OS (v.4.11) handheld operating with 8 megabytes of memory. The handheld and desktop databases were maintained secure using PDASecure (v.2.0) and GoldSecure (v.3.0) (Trust Digital LLC, Fairfax, Va). The handheld data were then uploaded to a desktop database of either FileMaker Pro 5.0 (v.1) (FileMaker Inc, Santa Clara, Calif) or Microsoft Access 2000 (Microsoft Corp, Redmond, Wash). Patient data were collected from 15 patients undergoing rhinoplasty in a private practice outpatient ambulatory setting. Data integrity was assessed after 6 months' disk and hard drive storage. The handheld database was able to facilitate data collection and accurately record, transfer, and reliably maintain perioperative rhinoplasty data. Query capability allowed rapid search using a multitude of keyword search terms specific to the operative maneuvers performed in rhinoplasty. Handheld computer technology provides a method of reliably recording and storing perioperative rhinoplasty information. The handheld computer facilitates the reliable and accurate storage and query of perioperative data, assisting the retrospective review of one's own results and enhancement of surgical skills.
NASA Astrophysics Data System (ADS)
Medzihradszky, Katalin F.; Trinidad, Jonathan C.
2012-04-01
During collision-induced dissociation (CID)-, phosphoserine- and phosphothreonine-containing peptides frequently undergo neutral loss of phosphoric acid. Subsequent amide bond cleavage N-terminal to the site of phosphorylation results in a y ion with a mass 18 Da lower than the corresponding unmodified y fragment. We report here that when the phosphoserine or phosphothreonine is directly preceded by a proline, an unusual fragment with a mass 10 Da higher than the corresponding unmodified y ion is frequently observed. Accurate mass measurements are consistent with elimination of the phosphoric acid followed by fragmentation between the α carbon and the carbonyl group of the proline residue. We propose a cyclic oxazoline structure for this fragment. Our observation may be explained by the charge-directed SN2 neighboring group participation reaction proposed for the phosphoric acid elimination by Palumbo et al. [Palumbo, A. M., Tepe, J. J., Reid, G. E. Mechanistic Insights into the Multistage Gas-Phase Fragmentation Behavior of Phosphoserine- and Phosphothreonine-Containing Peptides. J. Protein Res. 7(2), 771-779 (2008)]. Considering such specific fragment ions for confirmation purposes after regular database searches may boost the confidence of peptide identifications as well as phosphorylation site assignments.
Fang, Lian-xiang; Xiong, Ai-zhen; Wang, Rui; Ji, Shen; Yang, Li; Wang, Zheng-tao
2013-09-01
The objective of this study was to develop an effective strategy for screening and identifying mycotoxins in herbal medicine (HM). Here, Imperatae Rhizoma, a commonly used Chinese herb, was selected as a model HM. A crude drug contaminated with fungi was analyzed by comparing with uncontaminated ones. Ultra-performance LC coupled to tandem quadrupole TOF-MS (UPLC-Q-TOF-MS) with collision energy function was applied to analyze different samples from Imperatae Rhizoma. Then, MarkerLynx(TM) software was employed to screen the excess components in analytes, compared with control samples, and those selected markers were likely to be the metabolites of fungi. Furthermore, each of the accurate masses of the markers obtained from MarkerLynx(TM) was then searched in a mycotoxins/fungal metabolites database established in advance. The molecular formulas with relative mass error between the measured and theoretical mass within 5 ppm were chosen and then applied to MassFragment(TM) analysis for further confirmation of their structures. With the use of this approach, five mycotoxins that have never been reported in HM were identified in contaminated Imperatae Rhizoma. The results demonstrate the potential of UPLC-Q-TOF-MS coupled with the MarkerLynx(TM) software and MassFragment(TM) tool as an efficient and convenient method to screen and identify mycotoxins in herbal materials and aid in the quality control of HM. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Elnasir, Selma; Shamsuddin, Siti Mariyam; Farokhi, Sajad
2015-01-01
Palm vein recognition (PVR) is a promising new biometric that has been applied successfully as a method of access control by many organizations, which has even further potential in the field of forensics. The palm vein pattern has highly discriminative features that are difficult to forge because of its subcutaneous position in the palm. Despite considerable progress and a few practical issues, providing accurate palm vein readings has remained an unsolved issue in biometrics. We propose a robust and more accurate PVR method based on the combination of wavelet scattering (WS) with spectral regression kernel discriminant analysis (SRKDA). As the dimension of WS generated features is quite large, SRKDA is required to reduce the extracted features to enhance the discrimination. The results based on two public databases-PolyU Hyper Spectral Palmprint public database and PolyU Multi Spectral Palmprint-show the high performance of the proposed scheme in comparison with state-of-the-art methods. The proposed approach scored a 99.44% identification rate and a 99.90% verification rate [equal error rate (EER)=0.1%] for the hyperspectral database and a 99.97% identification rate and a 99.98% verification rate (EER=0.019%) for the multispectral database.
ERIC Educational Resources Information Center
Albright, Jessica C.; Dassenko, David J.; Mohamed, Essa A.; Beussman, Douglas J.
2009-01-01
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important bioanalytical technique in drug discovery, proteomics, and research at the biology-chemistry interface. This is an especially powerful tool when combined with gel separation of proteins and database mining using the mass spectral data. Currently, few hands-on…
MASS MEASUREMENTS BY AN ACCURATE AND SENSITIVE SELECTED ION RECORDING TECHNIQUE
Trace-level components of mixtures were successfully identified or confirmed by mass spectrometric accurate mass measurements, made at high resolution with selected ion recording, using GC and LC sample introduction. Measurements were made at 20 000 or 10 000 resolution, respecti...
Garner, O; Mochon, A; Branda, J; Burnham, C-A; Bythrow, M; Ferraro, M; Ginocchio, C; Jennemann, R; Manji, R; Procop, G W; Richter, S; Rychert, J; Sercia, L; Westblade, L; Lewinski, M
2014-04-01
Accurate and timely identification of anaerobic bacteria is critical to successful treatment. Classic phenotypic methods for identification require long turnaround times and can exhibit poor species level identification. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an identification method that can provide rapid identification of anaerobes. We present a multi-centre study assessing the clinical performance of the VITEK(®) MS in the identification of anaerobic bacteria. Five different test sites analysed a collection of 651 unique anaerobic isolates comprising 11 different genera. Multiple species were included for several of the genera. Briefly, anaerobic isolates were applied directly to a well of a target plate. Matrix solution (α-cyano-4-hydroxycinnamic acid) was added and allowed to dry. Mass spectra results were generated with the VITEK(®) MS, and the comparative spectral analysis and organism identification were determined using the VITEK(®) MS database 2.0. Results were confirmed by 16S rRNA gene sequencing. Of the 651 isolates analysed, 91.2% (594/651) exhibited the correct species identification. An additional eight isolates were correctly identified to genus level, raising the rate of identification to 92.5%. Genus-level identification consisted of Actinomyces, Bacteroides and Prevotella species. Fusobacterium nucleatum, Actinomyces neuii and Bacteroides uniformis were notable for an increased percentage of no-identification results compared with the other anaerobes tested. VITEK(®) MS identification of clinically relevant anaerobes is highly accurate and represents a dramatic improvement over other phenotypic methods in accuracy and turnaround time. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.
A general analytical platform and strategy in search for illegal drugs.
Johansson, Monika; Fransson, Dick; Rundlöf, Torgny; Huynh, Ngoc-Hang; Arvidsson, Torbjörn
2014-11-01
An effective screening procedure to identify and quantify active pharmaceutical substances in suspected illegal medicinal products is described. The analytical platform, consisting of accurate mass determination with liquid chromatography time-of-flight mass spectrometry (LC-QTOF-MS) in combination with nuclear magnetic resonance (NMR) spectroscopy provides an excellent analytical tool to screen for unknowns in medicinal products, food supplements and herbal formulations. This analytical approach has been successfully applied to analyze thousands of samples. The general screening method usually starts with a methanol extraction of tablets/capsules followed by liquid chromatographic separation on a Halo Phenyl-Hexyl column (2.7μm; 100mm×2.1mm) using an acetonitrile/0.1% formic acid gradient as eluent. The accurate mass of peaks of interest was recorded and a search made against an in-house database containing approximately 4200 substances, mostly pharmaceutical compounds. The search could be general or tailored against different classes of compounds. Hits were confirmed by analyzing a reference substance and/or by NMR. Quantification was normally performed with quantitative NMR (qNMR) spectroscopy. Applications for weight-loss substances like sibutramine and orlistat, sexual potency enhancement (PDE-5 inhibitors), and analgesic drugs are presented in this study. We have also identified prostaglandin analogues in eyelash growth serum, exemplified by isopropyl cloprostenate and bimatoprost. For creams and ointments, matrix solid-phase dispersion (MSPD) was found to give a clean extracts with high recovery prior to LC-MS analyses. The structural elucidation of cetilistat, a new weight-loss substance recently found in illegal medicines purchased over the Internet, is also presented. Copyright © 2014 Elsevier B.V. All rights reserved.
Roca, M; Leon, N; Pastor, A; Yusà, V
2014-12-29
In this study we propose an analytical strategy that combines a target approach for the quantitative analysis of contemporary pesticide metabolites with a comprehensive post-target screening for the identification of biomarkers of exposure to environmental contaminants in urine using liquid chromatography coupled to high-resolution mass spectrometry (LC–HRMS). The quantitative method for the target analysis of 29 urinary metabolites of organophosphate (OP) insecticides, synthetic pyrethroids, herbicides and fungicides was validated after a previous statistical optimization of the main factors governing the ion source ionization and a fragmentation study using the high energy collision dissociation (HCD) cell. The full scan accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), in both ESI+ and ESI− modes, and with and without HCD-fragmentation. The method – LOQ was lower than 3.2 μg L−1 for the majority of the analytes. For post-target screening a customized theoretical database was built, for the identification of 60 metabolites including pesticides, PAHs, phenols, and other metabolites of environmental pollutants. For identification purposes, accurate exact mass with less than 5 ppm, and diagnostic ions including isotopes and/or fragments were used. The analytical strategy was applied to 20 urine sample collected from children living in Valencia Region. Eleven target metabolites were detected with concentrations ranging from 1.18 to 131 μg L−1. Likewise, several compounds were tentatively identified in the post-target analysis belonging to the families of phthalates, phenols and parabenes. The proposed strategy is suitable for the determination of target pesticide biomarkers in urine in the framework of biomonitoring studies, and appropriate for the identification of other non-target metabolites.
van Walraven, Carl; Austin, Peter C; Manuel, Douglas; Knoll, Greg; Jennings, Allison; Forster, Alan J
2010-12-01
Administrative databases commonly use codes to indicate diagnoses. These codes alone are often inadequate to accurately identify patients with particular conditions. In this study, we determined whether we could quantify the probability that a person has a particular disease-in this case renal failure-using other routinely collected information available in an administrative data set. This would allow the accurate identification of a disease cohort in an administrative database. We determined whether patients in a randomly selected 100,000 hospitalizations had kidney disease (defined as two or more sequential serum creatinines or the single admission creatinine indicating a calculated glomerular filtration rate less than 60 mL/min/1.73 m²). The independent association of patient- and hospitalization-level variables with renal failure was measured using a multivariate logistic regression model in a random 50% sample of the patients. The model was validated in the remaining patients. Twenty thousand seven hundred thirteen patients had kidney disease (20.7%). A diagnostic code of kidney disease was strongly associated with kidney disease (relative risk: 34.4), but the accuracy of the code was poor (sensitivity: 37.9%; specificity: 98.9%). Twenty-nine patient- and hospitalization-level variables entered the kidney disease model. This model had excellent discrimination (c-statistic: 90.1%) and accurately predicted the probability of true renal failure. The probability threshold that maximized sensitivity and specificity for the identification of true kidney disease was 21.3% (sensitivity: 80.0%; specificity: 82.2%). Multiple variables available in administrative databases can be combined to quantify the probability that a person has a particular disease. This process permits accurate identification of a disease cohort in an administrative database. These methods may be extended to other diagnoses or procedures and could both facilitate and clarify the use of administrative databases for research and quality improvement. Copyright © 2010 Elsevier Inc. All rights reserved.
Operative record using intraoperative digital data in neurosurgery.
Houkin, K; Kuroda, S; Abe, H
2000-01-01
The purpose of this study was to develop a new method for more efficient and accurate operative records using intra-operative digital data in neurosurgery, including macroscopic procedures and microscopic procedures under an operating microscope. Macroscopic procedures were recorded using a digital camera and microscopic procedures were also recorded using a microdigital camera attached to an operating microscope. Operative records were then recorded digitally and filed in a computer using image retouch software and database base software. The time necessary for editing of the digital data and completing the record was less than 30 minutes. Once these operative records are digitally filed, they are easily transferred and used as database. Using digital operative records along with digital photography, neurosurgeons can document their procedures more accurately and efficiently than by the conventional method (handwriting). A complete digital operative record is not only accurate but also time saving. Construction of a database, data transfer and desktop publishing can be achieved using the intra-operative data, including intra-operative photographs.
Nakayama, Hiroshi; Akiyama, Misaki; Taoka, Masato; Yamauchi, Yoshio; Nobe, Yuko; Ishikawa, Hideaki; Takahashi, Nobuhiro; Isobe, Toshiaki
2009-04-01
We present here a method to correlate tandem mass spectra of sample RNA nucleolytic fragments with an RNA nucleotide sequence in a DNA/RNA sequence database, thereby allowing tandem mass spectrometry (MS/MS)-based identification of RNA in biological samples. Ariadne, a unique web-based database search engine, identifies RNA by two probability-based evaluation steps of MS/MS data. In the first step, the software evaluates the matches between the masses of product ions generated by MS/MS of an RNase digest of sample RNA and those calculated from a candidate nucleotide sequence in a DNA/RNA sequence database, which then predicts the nucleotide sequences of these RNase fragments. In the second step, the candidate sequences are mapped for all RNA entries in the database, and each entry is scored for a function of occurrences of the candidate sequences to identify a particular RNA. Ariadne can also predict post-transcriptional modifications of RNA, such as methylation of nucleotide bases and/or ribose, by estimating mass shifts from the theoretical mass values. The method was validated with MS/MS data of RNase T1 digests of in vitro transcripts. It was applied successfully to identify an unknown RNA component in a tRNA mixture and to analyze post-transcriptional modification in yeast tRNA(Phe-1).
Content Is King: Databases Preserve the Collective Information of Science.
Yates, John R
2018-04-01
Databases store sequence information experimentally gathered to create resources that further science. In the last 20 years databases have become critical components of fields like proteomics where they provide the basis for large-scale and high-throughput proteomic informatics. Amos Bairoch, winner of the Association of Biomolecular Resource Facilities Frederick Sanger Award, has created some of the important databases proteomic research depends upon for accurate interpretation of data.
NASA Astrophysics Data System (ADS)
Yin, Lucy; Andrews, Jennifer; Heaton, Thomas
2018-05-01
Earthquake parameter estimations using nearest neighbor searching among a large database of observations can lead to reliable prediction results. However, in the real-time application of Earthquake Early Warning (EEW) systems, the accurate prediction using a large database is penalized by a significant delay in the processing time. We propose to use a multidimensional binary search tree (KD tree) data structure to organize large seismic databases to reduce the processing time in nearest neighbor search for predictions. We evaluated the performance of KD tree on the Gutenberg Algorithm, a database-searching algorithm for EEW. We constructed an offline test to predict peak ground motions using a database with feature sets of waveform filter-bank characteristics, and compare the results with the observed seismic parameters. We concluded that large database provides more accurate predictions of the ground motion information, such as peak ground acceleration, velocity, and displacement (PGA, PGV, PGD), than source parameters, such as hypocenter distance. Application of the KD tree search to organize the database reduced the average searching process by 85% time cost of the exhaustive method, allowing the method to be feasible for real-time implementation. The algorithm is straightforward and the results will reduce the overall time of warning delivery for EEW.
Chow, Ian; Alghoul, Mohammed S; Khavanin, Nima; Hanwright, Philip J; Mayer, Kristen E; Hume, Keith M; Murphy, Robert X; Gutowski, Karol A; Kim, John Y S
2015-09-01
No concrete data exist to support a specific volume at which liposuction becomes unsafe; surgeons rely on their own estimates, professional organization advisories, or institutional or government-imposed restrictions. This study represents the first attempt to quantify the comprehensive risk associated with varying liposuction volumes and its interaction with body mass index. Suction-assisted lipectomies were identified from the Tracking Operations and Outcomes for Plastic Surgeons database. Multivariate regression models incorporating the interaction between liposuction volume and body mass index were used to assess the influence of liposuction volume on complications and to develop a tool that returns a single adjusted odds ratio for any combination of body mass index and liposuction volume. Recursive partitioning was used to determine whether exceeding a threshold in liposuction volume per body mass index unit significantly increased complications. Sixty-nine of 4534 patients (1.5 percent) meeting inclusion criteria experienced a postoperative complication. Liposuction volume and body mass index were significant independent risk factors for complications. With progressively higher volumes, increasing body mass index reduced risk (OR, 0.99; 95 percent CI, 0.98 to 0.99; p = 0.007). Liposuction volumes in excess of 100 ml per unit of body mass index were an independent predictor of complications (OR, 4.58; 95 percent CI, 2.60 to 8.05; p < 0.001). Liposuction by board-certified plastic surgeons is safe, with a low risk of life-threatening complications. Traditional liposuction volume thresholds do not accurately convey individualized risk. The authors' risk assessment model demonstrates that volumes in excess of 100 ml per unit of body mass index confer an increased risk of complications. Therapeutic, III.
Conversational high resolution mass spectrographic data reduction
NASA Technical Reports Server (NTRS)
Romiez, M. P.
1973-01-01
A FORTRAN 4 program is described which reduces the data obtained from a high resolution mass spectrograph. The program (1) calculates an accurate mass for each line on the photoplate, and (2) assigns elemental compositions to each accurate mass. The program is intended for use in a time-shared computing environment and makes use of the conversational aspects of time-sharing operating systems.
Breast mass segmentation in mammography using plane fitting and dynamic programming.
Song, Enmin; Jiang, Luan; Jin, Renchao; Zhang, Lin; Yuan, Yuan; Li, Qiang
2009-07-01
Segmentation is an important and challenging task in a computer-aided diagnosis (CAD) system. Accurate segmentation could improve the accuracy in lesion detection and characterization. The objective of this study is to develop and test a new segmentation method that aims at improving the performance level of breast mass segmentation in mammography, which could be used to provide accurate features for classification. This automated segmentation method consists of two main steps and combines the edge gradient, the pixel intensity, as well as the shape characteristics of the lesions to achieve good segmentation results. First, a plane fitting method was applied to a background-trend corrected region-of-interest (ROI) of a mass to obtain the edge candidate points. Second, dynamic programming technique was used to find the "optimal" contour of the mass from the edge candidate points. Area-based similarity measures based on the radiologist's manually marked annotation and the segmented region were employed as criteria to evaluate the performance level of the segmentation method. With the evaluation criteria, the new method was compared with 1) the dynamic programming method developed by Timp and Karssemeijer, and 2) the normalized cut segmentation method, based on 337 ROIs extracted from a publicly available image database. The experimental results indicate that our segmentation method can achieve a higher performance level than the other two methods, and the improvements in segmentation performance level were statistically significant. For instance, the mean overlap percentage for the new algorithm was 0.71, whereas those for Timp's dynamic programming method and the normalized cut segmentation method were 0.63 (P < .001) and 0.61 (P < .001), respectively. We developed a new segmentation method by use of plane fitting and dynamic programming, which achieved a relatively high performance level. The new segmentation method would be useful for improving the accuracy of computerized detection and classification of breast cancer in mammography.
Neighborhood Structural Similarity Mapping for the Classification of Masses in Mammograms.
Rabidas, Rinku; Midya, Abhishek; Chakraborty, Jayasree
2018-05-01
In this paper, two novel feature extraction methods, using neighborhood structural similarity (NSS), are proposed for the characterization of mammographic masses as benign or malignant. Since gray-level distribution of pixels is different in benign and malignant masses, more regular and homogeneous patterns are visible in benign masses compared to malignant masses; the proposed method exploits the similarity between neighboring regions of masses by designing two new features, namely, NSS-I and NSS-II, which capture global similarity at different scales. Complementary to these global features, uniform local binary patterns are computed to enhance the classification efficiency by combining with the proposed features. The performance of the features are evaluated using the images from the mini-mammographic image analysis society (mini-MIAS) and digital database for screening mammography (DDSM) databases, where a tenfold cross-validation technique is incorporated with Fisher linear discriminant analysis, after selecting the optimal set of features using stepwise logistic regression method. The best area under the receiver operating characteristic curve of 0.98 with an accuracy of is achieved with the mini-MIAS database, while the same for the DDSM database is 0.93 with accuracy .
Peptide Identification by Database Search of Mixture Tandem Mass Spectra*
Wang, Jian; Bourne, Philip E.; Bandeira, Nuno
2011-01-01
In high-throughput proteomics the development of computational methods and novel experimental strategies often rely on each other. In certain areas, mass spectrometry methods for data acquisition are ahead of computational methods to interpret the resulting tandem mass spectra. Particularly, although there are numerous situations in which a mixture tandem mass spectrum can contain fragment ions from two or more peptides, nearly all database search tools still make the assumption that each tandem mass spectrum comes from one peptide. Common examples include mixture spectra from co-eluting peptides in complex samples, spectra generated from data-independent acquisition methods, and spectra from peptides with complex post-translational modifications. We propose a new database search tool (MixDB) that is able to identify mixture tandem mass spectra from more than one peptide. We show that peptides can be reliably identified with up to 95% accuracy from mixture spectra while considering only a 0.01% of all possible peptide pairs (four orders of magnitude speedup). Comparison with current database search methods indicates that our approach has better or comparable sensitivity and precision at identifying single-peptide spectra while simultaneously being able to identify 38% more peptides from mixture spectra at significantly higher precision. PMID:21862760
Code of Federal Regulations, 2013 CFR
2013-04-01
..., section, or portion of this part: Accurate mass flow meter. A mass flow meter for making volume determinations of bulk distilled spirits. A mass flow meter used for tax determination of bulk spirits must be certified by the manufacturer of the meter or other qualified person as accurate within a tolerance of plus...
Code of Federal Regulations, 2012 CFR
2012-04-01
..., section, or portion of this part: Accurate mass flow meter. A mass flow meter for making volume determinations of bulk distilled spirits. A mass flow meter used for tax determination of bulk spirits must be certified by the manufacturer of the meter or other qualified person as accurate within a tolerance of plus...
Code of Federal Regulations, 2014 CFR
2014-04-01
..., section, or portion of this part: Accurate mass flow meter. A mass flow meter for making volume determinations of bulk distilled spirits. A mass flow meter used for tax determination of bulk spirits must be certified by the manufacturer of the meter or other qualified person as accurate within a tolerance of plus...
Code of Federal Regulations, 2011 CFR
2011-04-01
..., section, or portion of this part: Accurate mass flow meter. A mass flow meter for making volume determinations of bulk distilled spirits. A mass flow meter used for tax determination of bulk spirits must be certified by the manufacturer of the meter or other qualified person as accurate within a tolerance of plus...
MEASURING THE MASS OF SOLAR SYSTEM PLANETS USING PULSAR TIMING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Champion, D. J.; Hobbs, G. B.; Manchester, R. N.
High-precision pulsar timing relies on a solar system ephemeris in order to convert times of arrival (TOAs) of pulses measured at an observatory to the solar system barycenter. Any error in the conversion to the barycentric TOAs leads to a systematic variation in the observed timing residuals; specifically, an incorrect planetary mass leads to a predominantly sinusoidal variation having a period and phase associated with the planet's orbital motion about the Sun. By using an array of pulsars (PSRs J0437-4715, J1744-1134, J1857+0943, J1909-3744), the masses of the planetary systems from Mercury to Saturn have been determined. These masses are consistentmore » with the best-known masses determined by spacecraft observations, with the mass of the Jovian system, 9.547921(2) x10{sup -4} M {sub sun}, being significantly more accurate than the mass determined from the Pioneer and Voyager spacecraft, and consistent with but less accurate than the value from the Galileo spacecraft. While spacecraft are likely to produce the most accurate measurements for individual solar system bodies, the pulsar technique is sensitive to planetary system masses and has the potential to provide the most accurate values of these masses for some planets.« less
Targeted Quantification of Isoforms of a Thylakoid-Bound Protein: MRM Method Development.
Bru-Martínez, Roque; Martínez-Márquez, Ascensión; Morante-Carriel, Jaime; Sellés-Marchart, Susana; Martínez-Esteso, María José; Pineda-Lucas, José Luis; Luque, Ignacio
2018-01-01
Targeted mass spectrometric methods such as selected/multiple reaction monitoring (SRM/MRM) have found intense application in protein detection and quantification which competes with classical immunoaffinity techniques. It provides a universal procedure to develop a fast, highly specific, sensitive, accurate, and cheap methodology for targeted detection and quantification of proteins based on the direct analysis of their surrogate peptides typically generated by tryptic digestion. This methodology can be advantageously applied in the field of plant proteomics and particularly for non-model species since immunoreagents are scarcely available. Here, we describe the issues to take into consideration in order to develop a MRM method to detect and quantify isoforms of the thylakoid-bound protein polyphenol oxidase from the non-model and database underrepresented species Eriobotrya japonica Lindl.
NASA Technical Reports Server (NTRS)
Downward, James G.
1992-01-01
This document represents the final report for the View Generated Database (VGD) project, NAS7-1066. It documents the work done on the project up to the point at which all project work was terminated due to lack of project funds. The VGD was to provide the capability to accurately represent any real-world object or scene as a computer model. Such models include both an accurate spatial/geometric representation of surfaces of the object or scene, as well as any surface detail present on the object. Applications of such models are numerous, including acquisition and maintenance of work models for tele-autonomous systems, generation of accurate 3-D geometric/photometric models for various 3-D vision systems, and graphical models for realistic rendering of 3-D scenes via computer graphics.
Matsuda, Fumio; Nakabayashi, Ryo; Sawada, Yuji; Suzuki, Makoto; Hirai, Masami Y.; Kanaya, Shigehiko; Saito, Kazuki
2011-01-01
A novel framework for automated elucidation of metabolite structures in liquid chromatography–mass spectrometer metabolome data was constructed by integrating databases. High-resolution tandem mass spectra data automatically acquired from each metabolite signal were used for database searches. Three distinct databases, KNApSAcK, ReSpect, and the PRIMe standard compound database, were employed for the structural elucidation. The outputs were retrieved using the CAS metabolite identifier for identification and putative annotation. A simple metabolite ontology system was also introduced to attain putative characterization of the metabolite signals. The automated method was applied for the metabolome data sets obtained from the rosette leaves of 20 Arabidopsis accessions. Phenotypic variations in novel Arabidopsis metabolites among these accessions could be investigated using this method. PMID:22645535
Curtis, Matthew E; Jones, Patrick R; Sparkman, O David; Cody, Robert B
2009-11-01
Based on the concern about the presence of sulfur materials being in drywall (wallboard), a quick and reliable test to confirm the presence or absence of these materials using direct analysis in real time (DART) mass spectrometry in conjunction with an accurate-mass time-of-flight (TOF) mass spectrometer has been developed and is described here.
Schoch, Conrad L; Robbertse, Barbara; Robert, Vincent; Vu, Duong; Cardinali, Gianluigi; Irinyi, Laszlo; Meyer, Wieland; Nilsson, R Henrik; Hughes, Karen; Miller, Andrew N; Kirk, Paul M; Abarenkov, Kessy; Aime, M Catherine; Ariyawansa, Hiran A; Bidartondo, Martin; Boekhout, Teun; Buyck, Bart; Cai, Qing; Chen, Jie; Crespo, Ana; Crous, Pedro W; Damm, Ulrike; De Beer, Z Wilhelm; Dentinger, Bryn T M; Divakar, Pradeep K; Dueñas, Margarita; Feau, Nicolas; Fliegerova, Katerina; García, Miguel A; Ge, Zai-Wei; Griffith, Gareth W; Groenewald, Johannes Z; Groenewald, Marizeth; Grube, Martin; Gryzenhout, Marieka; Gueidan, Cécile; Guo, Liangdong; Hambleton, Sarah; Hamelin, Richard; Hansen, Karen; Hofstetter, Valérie; Hong, Seung-Beom; Houbraken, Jos; Hyde, Kevin D; Inderbitzin, Patrik; Johnston, Peter R; Karunarathna, Samantha C; Kõljalg, Urmas; Kovács, Gábor M; Kraichak, Ekaphan; Krizsan, Krisztina; Kurtzman, Cletus P; Larsson, Karl-Henrik; Leavitt, Steven; Letcher, Peter M; Liimatainen, Kare; Liu, Jian-Kui; Lodge, D Jean; Luangsa-ard, Janet Jennifer; Lumbsch, H Thorsten; Maharachchikumbura, Sajeewa S N; Manamgoda, Dimuthu; Martín, María P; Minnis, Andrew M; Moncalvo, Jean-Marc; Mulè, Giuseppina; Nakasone, Karen K; Niskanen, Tuula; Olariaga, Ibai; Papp, Tamás; Petkovits, Tamás; Pino-Bodas, Raquel; Powell, Martha J; Raja, Huzefa A; Redecker, Dirk; Sarmiento-Ramirez, J M; Seifert, Keith A; Shrestha, Bhushan; Stenroos, Soili; Stielow, Benjamin; Suh, Sung-Oui; Tanaka, Kazuaki; Tedersoo, Leho; Telleria, M Teresa; Udayanga, Dhanushka; Untereiner, Wendy A; Diéguez Uribeondo, Javier; Subbarao, Krishna V; Vágvölgyi, Csaba; Visagie, Cobus; Voigt, Kerstin; Walker, Donald M; Weir, Bevan S; Weiß, Michael; Wijayawardene, Nalin N; Wingfield, Michael J; Xu, J P; Yang, Zhu L; Zhang, Ning; Zhuang, Wen-Ying; Federhen, Scott
2014-01-01
DNA phylogenetic comparisons have shown that morphology-based species recognition often underestimates fungal diversity. Therefore, the need for accurate DNA sequence data, tied to both correct taxonomic names and clearly annotated specimen data, has never been greater. Furthermore, the growing number of molecular ecology and microbiome projects using high-throughput sequencing require fast and effective methods for en masse species assignments. In this article, we focus on selecting and re-annotating a set of marker reference sequences that represent each currently accepted order of Fungi. The particular focus is on sequences from the internal transcribed spacer region in the nuclear ribosomal cistron, derived from type specimens and/or ex-type cultures. Re-annotated and verified sequences were deposited in a curated public database at the National Center for Biotechnology Information (NCBI), namely the RefSeq Targeted Loci (RTL) database, and will be visible during routine sequence similarity searches with NR_prefixed accession numbers. A set of standards and protocols is proposed to improve the data quality of new sequences, and we suggest how type and other reference sequences can be used to improve identification of Fungi. Database URL: http://www.ncbi.nlm.nih.gov/bioproject/PRJNA177353. Published by Oxford University Press 2013. This work is written by US Government employees and is in the public domain in the US.
Jia, Zhixin; Wu, Caisheng; Jin, Hongtao; Zhang, Jinlan
2014-11-15
Saussurea involucrata is a rare traditional Chinese medicine (TCM) that displays anti-fatigue, anti-inflammatory and anti-tumor effects. In this paper, the different chemical components of Saussurea involucrata were characterized and identified over a wide dynamic range by high-performance liquid chromatography coupled with high-resolution hybrid mass spectrometry (HPLC/HRMS/MS(n)) and the mass spectral trees similarity filter (MTSF) technique. The aerial parts of Saussurea involucrata were extracted with 75% ethanol. The partial extract was separated on a chromatography column to concentrate the low-concentration compounds. Mass data were acquired using full-scan mass analysis (resolving power 50,000) with data-dependent incorporation of dynamic exclusion analysis. The identified compounds were used as templates to construct a database of mass spectral trees. Data for the unknown compounds were matched with those templates and matching candidate structures were obtained. The detected compounds were characterized based on matching to candidate structures by the MTSF technique and were further identified by their accurate mass weight, multiple-stage analysis and fragmentation patterns and through comparison with literature data. A total of 38 compounds were identified including 19 flavones, 11 phenylpropanoids and 8 sphingolipids. Among them, 7 flavonoids, 8 phenylpropanoids and 8 sphingolipids were identified for the first time in Saussurea involucrata. HPLC/HRMS/MS(n) combined with MTSF was successfully used to discover and identify the chemical compounds in Saussurea involucrata. The results indicated that this combined technique was extremely useful for the rapid detection and identification of the chemical components in TCMs. Copyright © 2014 John Wiley & Sons, Ltd.
NATIONAL URBAN DATABASE AND ACCESS PROTAL TOOL
Current mesoscale weather prediction and microscale dispersion models are limited in their ability to perform accurate assessments in urban areas. A project called the National Urban Database with Access Portal Tool (NUDAPT) is beginning to provide urban data and improve the para...
Advances in computational metabolomics and databases deepen the understanding of metabolisms.
Tsugawa, Hiroshi
2018-01-29
Mass spectrometry (MS)-based metabolomics is the popular platform for metabolome analyses. Computational techniques for the processing of MS raw data, for example, feature detection, peak alignment, and the exclusion of false-positive peaks, have been established. The next stage of untargeted metabolomics would be to decipher the mass fragmentation of small molecules for the global identification of human-, animal-, plant-, and microbiota metabolomes, resulting in a deeper understanding of metabolisms. This review is an update on the latest computational metabolomics including known/expected structure databases, chemical ontology classifications, and mass spectrometry cheminformatics for the interpretation of mass fragmentations and for the elucidation of unknown metabolites. The importance of metabolome 'databases' and 'repositories' is also discussed because novel biological discoveries are often attributable to the accumulation of data, to relational databases, and to their statistics. Lastly, a practical guide for metabolite annotations is presented as the summary of this review. Copyright © 2018 Elsevier Ltd. All rights reserved.
Empirical cost models for estimating power and energy consumption in database servers
NASA Astrophysics Data System (ADS)
Valdivia Garcia, Harold Dwight
The explosive growth in the size of data centers, coupled with the widespread use of virtualization technology has brought power and energy consumption as major concerns for data center administrators. Provisioning decisions must take into consideration not only target application performance but also the power demands and total energy consumption incurred by the hardware and software to be deployed at the data center. Failure to do so will result in damaged equipment, power outages, and inefficient operation. Since database servers comprise one of the most popular and important server applications deployed in such facilities, it becomes necessary to have accurate cost models that can predict the power and energy demands that each database workloads will impose in the system. In this work we present an empirical methodology to estimate the power and energy cost of database operations. Our methodology uses multiple-linear regression to derive accurate cost models that depend only on readily available statistics such as selectivity factors, tuple size, numbers columns and relational cardinality. Moreover, our method does not need measurement of individual hardware components, but rather total power and energy consumption measured at a server. We have implemented our methodology, and ran experiments with several server configurations. Our experiments indicate that we can predict power and energy more accurately than alternative methods found in the literature.
Dhanasekaran, A Ranjitha; Pearson, Jon L; Ganesan, Balasubramanian; Weimer, Bart C
2015-02-25
Mass spectrometric analysis of microbial metabolism provides a long list of possible compounds. Restricting the identification of the possible compounds to those produced by the specific organism would benefit the identification process. Currently, identification of mass spectrometry (MS) data is commonly done using empirically derived compound databases. Unfortunately, most databases contain relatively few compounds, leaving long lists of unidentified molecules. Incorporating genome-encoded metabolism enables MS output identification that may not be included in databases. Using an organism's genome as a database restricts metabolite identification to only those compounds that the organism can produce. To address the challenge of metabolomic analysis from MS data, a web-based application to directly search genome-constructed metabolic databases was developed. The user query returns a genome-restricted list of possible compound identifications along with the putative metabolic pathways based on the name, formula, SMILES structure, and the compound mass as defined by the user. Multiple queries can be done simultaneously by submitting a text file created by the user or obtained from the MS analysis software. The user can also provide parameters specific to the experiment's MS analysis conditions, such as mass deviation, adducts, and detection mode during the query so as to provide additional levels of evidence to produce the tentative identification. The query results are provided as an HTML page and downloadable text file of possible compounds that are restricted to a specific genome. Hyperlinks provided in the HTML file connect the user to the curated metabolic databases housed in ProCyc, a Pathway Tools platform, as well as the KEGG Pathway database for visualization and metabolic pathway analysis. Metabolome Searcher, a web-based tool, facilitates putative compound identification of MS output based on genome-restricted metabolic capability. This enables researchers to rapidly extend the possible identifications of large data sets for metabolites that are not in compound databases. Putative compound names with their associated metabolic pathways from metabolomics data sets are returned to the user for additional biological interpretation and visualization. This novel approach enables compound identification by restricting the possible masses to those encoded in the genome.
Hnatyshyn, S.; Reily, M.; Shipkova, P.; McClure, T.; Sanders, M.; Peake, D.
2011-01-01
Robust biomarkers of target engagement and efficacy are required in different stages of drug discovery. Liquid chromatography coupled to high resolution mass spectrometry provides sensitivity, accuracy and wide dynamic range required for identification of endogenous metabolites in biological matrices. LCMS is widely-used tool for biomarker identification and validation. Typical high resolution LCMS profiles from biological samples may contain greater than a million mass spectral peaks corresponding to several thousand endogenous metabolites. Reduction of the total number of peaks, component identification and statistical comparison across sample groups remains to be a difficult and time consuming challenge. Blood samples from four groups of rats (male vs. female, fully satiated and food deprived) were analyzed using high resolution accurate mass (HRAM) LCMS. All samples were separated using a 15 minute reversed-phase C18 LC gradient and analyzed in both positive and negative ion modes. Data was acquired using 15K resolution and 5ppm mass measurement accuracy. The entire data set was analyzed using software developed in collaboration between Bristol Meyers Squibb and Thermo Fisher Scientific to determine the metabolic effects of food deprivation on rats. Metabolomic LC-MS data files are extraordinarily complex and appropriate reduction of the number of spectral peaks via identification of related peaks and background removal is essential. A single component such as hippuric acid generates more than 20 related peaks including isotopic clusters, adducts and dimers. Plasma and urine may contain 500-1500 unique quantifiable metabolites. Noise filtering approaches including blank subtraction were used to reduce the number of irrelevant peaks. By grouping related signals such as isotopic peaks and alkali adducts, data processing was greatly simplified by reducing the total number of components by 10-fold. The software processes 48 samples in under 60minutes. Principle Component Analysis showed substantial differences in endogenous metabolites levels between the animal groups. Annotation of components was accomplished via searching the ChemSpider database. Tentative assignments made using accurate mass need further verification by comparison with the retention time of authentic standards.
NASA Astrophysics Data System (ADS)
Schenk, A. F.; Csatho, B. M.; van den Broeke, M.; Kuipers Munneke, P.
2015-12-01
This paper reports about important upgrades of the Greenland Ice Sheet (GrIS) surface elevation and elevation-change database obtained with our Surface Elevation And Change detection (SERAC) software suite. We have developed SERAC to derive information from laser altimetry data, particularly time series of elevation changes and their partitioning into changes caused by ice dynamics. This allows direct investigation of ice dynamic processes that is much needed for improving the predictive power of ice sheet models. SERAC is different from most other change detection methods. It is based on detecting changes of surface patches, about 1 km by 1 km in size, rather than deriving elevation changes from individual laser points. The current database consists of ~100,000 time series with satellite laser altimetry data from ICESat, airborne laser observations obtained by NASA's Airborne Topographic Mapper (ATM) and the Land, Vegetation and Ice Sensor (LVIS). The upgrade is significant, because not only new observations from 2013 and 2014 have been added but also a number of improvements lead to a more comprehensive and consistent record of elevation-changes. First, we used the model that gives in addition to ice sheet also information about ice caps and glaciers (Rastner et al., 2012) for deciding if a laser point is on the ice sheet or ice cap. Then we added small gaps that exist in the ICESat GLA12 data set because the ice sheet mask is not wide enough. The new database is now more complete and will facilitate more accurate comparisons of mass balance studies obtained from the Gravity Recovery and Climate Experiment system (GRACE). For determining the part of a time series caused by ice dynamics we used the new firn compaction model and Surface Mass Balance (SMB) estimates from RACMO2.3. The new database spans the time period from 1993 to 2014. Adding new observations amounts to a spatial densification of the old record and at the same time extends the time domain by two years. Our presentation will show the improvement of the reconstruction of the total changes, those caused by SMB and ice dynamic during the ICESat mission (2003-2009). Moreover we will review changes on scales from individual outlet glaciers to drainage basins and the entire ice sheet.
Young, Mariel; Johannesdottir, Fjola; Poole, Ken; Shaw, Colin; Stock, J T
2018-02-01
Femoral head diameter is commonly used to estimate body mass from the skeleton. The three most frequently employed methods, designed by Ruff, Grine, and McHenry, were developed using different populations to address different research questions. They were not specifically designed for application to female remains, and their accuracy for this purpose has rarely been assessed or compared in living populations. This study analyzes the accuracy of these methods using a sample of modern British women through the use of pelvic CT scans (n = 97) and corresponding information about the individuals' known height and weight. Results showed that all methods provided reasonably accurate body mass estimates (average percent prediction errors under 20%) for the normal weight and overweight subsamples, but were inaccurate for the obese and underweight subsamples (average percent prediction errors over 20%). When women of all body mass categories were combined, the methods provided reasonable estimates (average percent prediction errors between 16 and 18%). The results demonstrate that different methods provide more accurate results within specific body mass index (BMI) ranges. The McHenry Equation provided the most accurate estimation for women of small body size, while the original Ruff Equation is most likely to be accurate if the individual was obese or severely obese. The refined Ruff Equation was the most accurate predictor of body mass on average for the entire sample, indicating that it should be utilized when there is no knowledge of the individual's body size or if the individual is assumed to be of a normal body size. The study also revealed a correlation between pubis length and body mass, and an equation for body mass estimation using pubis length was accurate in a dummy sample, suggesting that pubis length can also be used to acquire reliable body mass estimates. This has implications for how we interpret body mass in fossil hominins and has particular relevance to the interpretation of the long pubic ramus that is characteristic of Neandertals. Copyright © 2017 Elsevier Ltd. All rights reserved.
A literature search tool for intelligent extraction of disease-associated genes.
Jung, Jae-Yoon; DeLuca, Todd F; Nelson, Tristan H; Wall, Dennis P
2014-01-01
To extract disorder-associated genes from the scientific literature in PubMed with greater sensitivity for literature-based support than existing methods. We developed a PubMed query to retrieve disorder-related, original research articles. Then we applied a rule-based text-mining algorithm with keyword matching to extract target disorders, genes with significant results, and the type of study described by the article. We compared our resulting candidate disorder genes and supporting references with existing databases. We demonstrated that our candidate gene set covers nearly all genes in manually curated databases, and that the references supporting the disorder-gene link are more extensive and accurate than other general purpose gene-to-disorder association databases. We implemented a novel publication search tool to find target articles, specifically focused on links between disorders and genotypes. Through comparison against gold-standard manually updated gene-disorder databases and comparison with automated databases of similar functionality we show that our tool can search through the entirety of PubMed to extract the main gene findings for human diseases rapidly and accurately.
Wyatt, Mark F; Stein, Bridget K; Brenton, A Gareth
2006-05-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been shown to be an effective technique for the characterization of organometallic, coordination, and highly conjugated compounds. The preferred matrix is 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), with radical ions observed. However, MALDI-TOFMS is generally not favored for accurate mass measurement. A specific method had to be developed for such compounds to assure the quality of our accurate mass results. Therefore, in this preliminary study, two methods of data acquisition, and both even-electron (EE+) ion and odd-electron (OE+.) radical ion mass calibration standards, have been investigated to establish the basic measurement technique. The benefit of this technique is demonstrated for a copper compound for which ions were observed by MALDI, but not by electrospray (ESI) or liquid secondary ion mass spectrometry (LSIMS); a mean mass accuracy error of -1.2 ppm was obtained.
NASA Technical Reports Server (NTRS)
Campbell, William J.; Short, Nicholas M., Jr.; Roelofs, Larry H.; Dorfman, Erik
1991-01-01
A methodology for optimizing organization of data obtained by NASA earth and space missions is discussed. The methodology uses a concept based on semantic data modeling techniques implemented in a hierarchical storage model. The modeling is used to organize objects in mass storage devices, relational database systems, and object-oriented databases. The semantic data modeling at the metadata record level is examined, including the simulation of a knowledge base and semantic metadata storage issues. The semantic data model hierarchy and its application for efficient data storage is addressed, as is the mapping of the application structure to the mass storage.
The Knowledge-Integrated Network Biomarkers Discovery for Major Adverse Cardiac Events
Jin, Guangxu; Zhou, Xiaobo; Wang, Honghui; Zhao, Hong; Cui, Kemi; Zhang, Xiang-Sun; Chen, Luonan; Hazen, Stanley L.; Li, King; Wong, Stephen T. C.
2010-01-01
The mass spectrometry (MS) technology in clinical proteomics is very promising for discovery of new biomarkers for diseases management. To overcome the obstacles of data noises in MS analysis, we proposed a new approach of knowledge-integrated biomarker discovery using data from Major Adverse Cardiac Events (MACE) patients. We first built up a cardiovascular-related network based on protein information coming from protein annotations in Uniprot, protein–protein interaction (PPI), and signal transduction database. Distinct from the previous machine learning methods in MS data processing, we then used statistical methods to discover biomarkers in cardiovascular-related network. Through the tradeoff between known protein information and data noises in mass spectrometry data, we finally could firmly identify those high-confident biomarkers. Most importantly, aided by protein–protein interaction network, that is, cardiovascular-related network, we proposed a new type of biomarkers, that is, network biomarkers, composed of a set of proteins and the interactions among them. The candidate network biomarkers can classify the two groups of patients more accurately than current single ones without consideration of biological molecular interaction. PMID:18665624
Nikolić, Dejan; Gödecke, Tanja; Chen, Shao-Nong; White, Jerry; Lankin, David C.; Pauli, Guido F.; van Breemen, Richard B.
2011-01-01
Black cohosh preparations are popular dietary supplements among women seeking alternative treatments for menopausal complaints. For decades, triterpene glycosides and phenolic acids have dominated the phytochemical and biomedical research on this plant. In this study, we provide evidence that black cohosh contains an unexpected and highly diverse group of secondary nitrogenous metabolites previously unknown to exist in this plant. Using a dereplication approach that combines accurate mass measurements, database searches and general knowledge of biosynthetic pathways of natural products, we identified or tentatively identified 73 nitrogen-containing metabolites, many of which are new natural products. The identified compounds belong to several structural groups including alkaloids, amides or esters of hydroxycinnamic acids and betains. Among the alkaloids, several classes such as guanidino alkaloids, isoquinolines and β-carbolines were identified. Fragmentation patterns for major compound classes are discussed, which provides a framework for the discovery of these compounds from other sources. Identification of alkaloids as a well-known group of bioactive natural products represents an important advance in better understanding of the pharmacological profile of black cohosh. PMID:22178683
Progesterone potentially degrades to potent androgens in surface waters.
Ojoghoro, Jasper O; Chaudhary, Abdul J; Campo, Pablo; Sumpter, John P; Scrimshaw, Mark D
2017-02-01
Progesterone is a natural hormone, excreted in higher concentrations than estrogens, and has been detected in the aqueous environment. As with other compounds, it is transformed during wastewater treatment processes and in the environment. However, minor modifications to the structure may result in transformation products which still exhibit biological activity, so understanding what transformation products are formed is of importance. The current study was undertaken to identify putative transformation products resulting from spiking river water with progesterone in a laboratory-based degradation study and hence to follow the metabolic breakdown pathways. On the basis of literature reports and predictions from the EAWAG Biocatalysis/biodegradation database, target putative transformation products were initially monitored under unit resolution mass spectrometry. The identity of these transformation products was confirmed by using accurate-mass quadrupole time-of-flight. The study results highlight that transformation of progesterone can potentially create other classes of steroids, some of which may still be potent, and possess other types of biological activity. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Rudrik, James T; Soehnlen, Marty K; Perry, Michael J; Sullivan, Maureen M; Reiter-Kintz, Wanda; Lee, Philip A; Pettit, Denise; Tran, Anthony; Swaney, Erin
2017-12-01
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) sample preparation methods, including the direct, on-plate formic acid, and ethanol/formic acid tube extraction methods, were evaluated for their ability to render highly pathogenic organisms nonviable and safe for handling in a biosafety level 2 laboratory. Of these, the tube extraction procedure was the most successful, with none of the tested strains surviving this sample preparation method. Tube extracts from several agents of bioterrorism and their near neighbors were analyzed in an eight-laboratory study to examine the utility of the Bruker Biotyper and Vitek MS MALDI-TOF MS systems and their in vitro diagnostic (IVD), research-use-only, and Security-Relevant databases, as applicable, to accurately identify these agents. Forty-six distinct strains of Bacillus anthracis , Yersinia pestis , Francisella tularensis , Burkholderia mallei , Burkholderia pseudomallei , Clostridium botulinum , Brucella melitensis , Brucella abortus , Brucella suis , and Brucella canis were extracted and distributed to participating laboratories for analysis. A total of 35 near-neighbor isolates were also analyzed. Copyright © 2017 Rudrik et al.
Würtinger, Philipp; Oberacher, Herbert
2012-01-01
MSforID represents a database of tandem mass spectral data obtained from (quasi-)molecular ions produced by atmospheric pressure ionization methods. At the current stage of development the library contains 12 122 spectra of 1208 small (bio-)organic molecules. The present work was aimed to evaluate the performance of the MSforID library in terms of accuracy and transferability with a collection of fragment ion mass spectra from various compounds acquired on multiple instruments. A literature survey was conducted to collect the set of sample spectra. A total number of 554 spectra covering 291 compounds were extracted from 109 publications. The majority of spectra originated from publications on applications of LC/MS/MS in drug monitoring, pharmacokinetics, environmental analysis, forensic analysis as well as food analysis. Almost all types of tandem mass spectrometric instruments distributed by the five most important instrument vendors were included in the study. The overall sensitivity of library search was found to be 96.4%, which clearly proves that the MSforID library can successfully handle data from a huge variety of mass spectrometric instruments to allow accurate compound identification. Only for spectra containing three or more fragment ions, however, the rate of classified matches (= matches with a relative average match probability (ramp) score > 40.0) was 95%. Ambiguous or unclassified results were mainly obtained for searches with single precursor-to-fragment ion transitions due to the insufficient specificity of such a low amount of structural information to unequivocally define a single compound. Copyright © 2011 John Wiley & Sons, Ltd.
A Generic Nonlinear Aerodynamic Model for Aircraft
NASA Technical Reports Server (NTRS)
Grauer, Jared A.; Morelli, Eugene A.
2014-01-01
A generic model of the aerodynamic coefficients was developed using wind tunnel databases for eight different aircraft and multivariate orthogonal functions. For each database and each coefficient, models were determined using polynomials expanded about the state and control variables, and an othgonalization procedure. A predicted squared-error criterion was used to automatically select the model terms. Modeling terms picked in at least half of the analyses, which totalled 45 terms, were retained to form the generic nonlinear aerodynamic (GNA) model. Least squares was then used to estimate the model parameters and associated uncertainty that best fit the GNA model to each database. Nonlinear flight simulations were used to demonstrate that the GNA model produces accurate trim solutions, local behavior (modal frequencies and damping ratios), and global dynamic behavior (91% accurate state histories and 80% accurate aerodynamic coefficient histories) under large-amplitude excitation. This compact aerodynamics model can be used to decrease on-board memory storage requirements, quickly change conceptual aircraft models, provide smooth analytical functions for control and optimization applications, and facilitate real-time parametric system identification.
Van Berkel, Gary J.; Kertesz, Vilmos
2016-11-15
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.; Kertesz, Vilmos
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
NASA Astrophysics Data System (ADS)
Saslow, Wayne M.
2014-04-01
Three common approaches to F→=ma→ are: (1) as an exactly true definition of force F→ in terms of measured inertial mass m and measured acceleration a→; (2) as an exactly true axiom relating measured values of a→, F→ and m; and (3) as an imperfect but accurately true physical law relating measured a→ to measured F→, with m an experimentally determined, matter-dependent constant, in the spirit of the resistance R in Ohm's law. In the third case, the natural units are those of a→ and F→, where a→ is normally specified using distance and time as standard units, and F→ from a spring scale as a standard unit; thus mass units are derived from force, distance, and time units such as newtons, meters, and seconds. The present work develops the third approach when one includes a second physical law (again, imperfect but accurate)—that balance-scale weight W is proportional to m—and the fact that balance-scale measurements of relative weight are more accurate than those of absolute force. When distance and time also are more accurately measurable than absolute force, this second physical law permits a shift to standards of mass, distance, and time units, such as kilograms, meters, and seconds, with the unit of force—the newton—a derived unit. However, were force and distance more accurately measurable than time (e.g., time measured with an hourglass), this second physical law would permit a shift to standards of force, mass, and distance units such as newtons, kilograms, and meters, with the unit of time—the second—a derived unit. Therefore, the choice of the most accurate standard units depends both on what is most accurately measurable and on the accuracy of physical law.
Cameron, M; Perry, J; Middleton, J R; Chaffer, M; Lewis, J; Keefe, G P
2018-01-01
This study evaluated MALDI-TOF mass spectrometry and a custom reference spectra expanded database for the identification of bovine-associated coagulase-negative staphylococci (CNS). A total of 861 CNS isolates were used in the study, covering 21 different CNS species. The majority of the isolates were previously identified by rpoB gene sequencing (n = 804) and the remainder were identified by sequencing of hsp60 (n = 56) and tuf (n = 1). The genotypic identification was considered the gold standard identification. Using a direct transfer protocol and the existing commercial database, MALDI-TOF mass spectrometry showed a typeability of 96.5% (831/861) and an accuracy of 99.2% (824/831). Using a custom reference spectra expanded database, which included an additional 13 in-house created reference spectra, isolates were identified by MALDI-TOF mass spectrometry with 99.2% (854/861) typeability and 99.4% (849/854) accuracy. Overall, MALDI-TOF mass spectrometry using the direct transfer method was shown to be a highly reliable tool for the identification of bovine-associated CNS. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NIST Libraries of Peptide Fragmentation Mass Spectra Databass
National Institute of Standards and Technology Data Gateway
SRD 4 NIST Libraries of Peptide Fragmentation Mass Spectra Databass (PC database for purchase) Interactive computer program for predicting thermodynamic and transport properties of pure fluids and fluid mixtures containing up to 20 components. The components are selected from a database of 196 components, mostly hydrocarbons.
Accurate and precise determination of isotopic ratios by MC-ICP-MS: a review.
Yang, Lu
2009-01-01
For many decades the accurate and precise determination of isotope ratios has remained a very strong interest to many researchers due to its important applications in earth, environmental, biological, archeological, and medical sciences. Traditionally, thermal ionization mass spectrometry (TIMS) has been the technique of choice for achieving the highest accuracy and precision. However, recent developments in multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) have brought a new dimension to this field. In addition to its simple and robust sample introduction, high sample throughput, and high mass resolution, the flat-topped peaks generated by this technique provide for accurate and precise determination of isotope ratios with precision reaching 0.001%, comparable to that achieved with TIMS. These features, in combination with the ability of the ICP source to ionize nearly all elements in the periodic table, have resulted in an increased use of MC-ICP-MS for such measurements in various sample matrices. To determine accurate and precise isotope ratios with MC-ICP-MS, utmost care must be exercised during sample preparation, optimization of the instrument, and mass bias corrections. Unfortunately, there are inconsistencies and errors evident in many MC-ICP-MS publications, including errors in mass bias correction models. This review examines "state-of-the-art" methodologies presented in the literature for achievement of precise and accurate determinations of isotope ratios by MC-ICP-MS. Some general rules for such accurate and precise measurements are suggested, and calculations of combined uncertainty of the data using a few common mass bias correction models are outlined.
Selby, Luke V; Sjoberg, Daniel D; Cassella, Danielle; Sovel, Mindy; Weiser, Martin R; Sepkowitz, Kent; Jones, David R; Strong, Vivian E
2015-06-15
Surgical quality improvement requires accurate tracking and benchmarking of postoperative adverse events. We track surgical site infections (SSIs) with two systems; our in-house surgical secondary events (SSE) database and the National Surgical Quality Improvement Project (NSQIP). The SSE database, a modification of the Clavien-Dindo classification, categorizes SSIs by their anatomic site, whereas NSQIP categorizes by their level. Our aim was to directly compare these different definitions. NSQIP and the SSE database entries for all surgeries performed in 2011 and 2012 were compared. To match NSQIP definitions, and while blinded to NSQIP results, entries in the SSE database were categorized as either incisional (superficial or deep) or organ space infections. These categorizations were compared with NSQIP records; agreement was assessed with Cohen kappa. The 5028 patients in our cohort had a 6.5% SSI in the SSE database and a 4% rate in NSQIP, with an overall agreement of 95% (kappa = 0.48, P < 0.0001). The rates of categorized infections were similarly well matched; incisional rates of 4.1% and 2.7% for the SSE database and NSQIP and organ space rates of 2.6% and 1.5%. Overall agreements were 96% (kappa = 0.36, P < 0.0001) and 98% (kappa = 0.55, P < 0.0001), respectively. Over 80% of cases recorded by the SSE database but not NSQIP did not meet NSQIP criteria. The SSE database is an accurate, real-time record of postoperative SSIs. Institutional databases that capture all surgical cases can be used in conjunction with NSQIP with excellent concordance. Copyright © 2015 Elsevier Inc. All rights reserved.
Ultra-precise single-ion atomic mass measurements on deuterium and helium-3
NASA Astrophysics Data System (ADS)
Zafonte, S. L.; Van Dyck, R. S., Jr.
2015-04-01
The former University of Washington Penning Trap Mass Spectrometer (UW-PTMS), now located at the Max Planck Institute for Nuclear Physics in Heidelberg, Germany, was used in the decade before the move to determine new values for the deuteron atomic mass, M (2H+) = 2.013 553 212 745(40) u, and the deuterium atomic mass, M (2H) = 2.014 101 778 052(40) u, both of which are now more than an order-of-magnitude more accurate than the previous best 1994-MIT measurements of these quantities. The new value for the deuteron’s mass can then be used with the accepted 2010-CODATA proton mass and the most recent 1999-measurement of the 2.2 MeV gamma-ray binding energy of the deuteron to refine the neutron’s mass to mn = 1.008 664 916 018(435) u which has about half the uncertainty relative to the value computed using that previous 1994-MIT deuterium measurement. As a result, further improvements of mn must now come from a more accurate determination of the wavelength of this gamma ray. In this same period of time, this spectrometer has also been used to determine new values for the helion atomic mass, M (3He2+) = 3.014 932 246 668(43) u, and the neutral helium-3 atomic mass, M (3He) = 3.016 029 321 675(43) u, which are both about 60 times more accurate than the 2006-SMILETRAP measurements, but disagree with the 4.4-times less-accurate 2015-Florida-State measurements by 0.76 nu. It is expected that these helium-3 results will be used in the future 3H/3He mass ratio (to be determined by the Heidelberg, Germany version of the old UW-PTMS) in order to generate a more accurate value for the tritium atomic mass.
Entomopathogen ID: a curated sequence resource for entomopathogenic fungi
USDA-ARS?s Scientific Manuscript database
We report the development of a publicly accessible, curated database of Hypocrealean entomopathogenic fungi sequence data. The goal is to provide a platform for users to easily access sequence data from reference strains. The database can be used to accurately identify unknown entomopathogenic fungi...
Floden, Evan W; Tommaso, Paolo D; Chatzou, Maria; Magis, Cedrik; Notredame, Cedric; Chang, Jia-Ming
2016-07-08
The PSI/TM-Coffee web server performs multiple sequence alignment (MSA) of proteins by combining homology extension with a consistency based alignment approach. Homology extension is performed with Position Specific Iterative (PSI) BLAST searches against a choice of redundant and non-redundant databases. The main novelty of this server is to allow databases of reduced complexity to rapidly perform homology extension. This server also gives the possibility to use transmembrane proteins (TMPs) reference databases to allow even faster homology extension on this important category of proteins. Aside from an MSA, the server also outputs topological prediction of TMPs using the HMMTOP algorithm. Previous benchmarking of the method has shown this approach outperforms the most accurate alignment methods such as MSAProbs, Kalign, PROMALS, MAFFT, ProbCons and PRALINE™. The web server is available at http://tcoffee.crg.cat/tmcoffee. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.
NASA Astrophysics Data System (ADS)
Samsing, Johan; Askar, Abbas; Giersz, Mirek
2018-03-01
We estimate the population of eccentric gravitational wave (GW) binary black hole (BBH) mergers forming during binary–single interactions in globular clusters (GCs), using ∼800 GC models that were evolved using the MOCCA code for star cluster simulations as part of the MOCCA-Survey Database I project. By re-simulating BH binary–single interactions extracted from this set of GC models using an N-body code that includes GW emission at the 2.5 post-Newtonian level, we find that ∼10% of all the BBHs assembled in our GC models that merge at present time form during chaotic binary–single interactions, and that about half of this sample have an eccentricity >0.1 at 10 Hz. We explicitly show that this derived rate of eccentric mergers is ∼100 times higher than one would find with a purely Newtonian N-body code. Furthermore, we demonstrate that the eccentric fraction can be accurately estimated using a simple analytical formalism when the interacting BHs are of similar mass, a result that serves as the first successful analytical description of eccentric GW mergers forming during three-body interactions in realistic GCs.
Gogaert, Stefan; Vande Veegaete, Axel; Scholliers, Annelies; Vandekerckhove, Philippe
2016-10-01
First aid (FA) services are provisioned on-site as a preventive measure at most public events. In Flanders, Belgium, the Belgian Red Cross-Flanders (BRCF) is the major provider of these FA services with volunteers being deployed at approximately 10,000 public events annually. The BRCF has systematically registered information on the patients being treated in FA posts at major events and mass gatherings during the last 10 years. This information has been collected in a web-based client server system called "MedTRIS" (Medical Triage and Registration Informatics System). MedTRIS contains data on more than 200,000 patients at 335 mass events. This report describes the MedTRIS architecture, the data collected, and how the system operates in the field. This database consolidates different types of information with regards to FA interventions in a standardized way for a variety of public events. MedTRIS allows close monitoring in "real time" of the situation at mass gatherings and immediate intervention, when necessary; allows more accurate prediction of resources needed; allows to validate conceptual and predictive models for medical resources at (mass) public events; and can contribute to the definition of a standardized minimum data set (MDS) for mass-gathering health research and evaluation. Gogaert S , Vande veegaete A , Scholliers A , Vandekerckhove P . "MedTRIS" (Medical Triage and Registration Informatics System): a web-based client server system for the registration of patients being treated in first aid posts at public events and mass gatherings. Prehosp Disaster Med. 2016;31(5):557-562.
Chen, Ying-Sheng; Liu, Yen-Hung; Teng, Shih-Hua; Liao, Chun-Hsing; Hung, Chien-Ching; Sheng, Wang-Huei; Teng, Lee-Jene; Hsueh, Po-Ren
2015-01-01
We evaluated the performance of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS), the MALDI Bruker Biotyper system (microflex LT; Bruker Daltonik GmbH, Bremen, Germany), on the identification of 50 isolates of clinically encountered molds, including Penicillium marneffei (n = 28), Paecilomyces species (n = 12), Fusarium solani (n = 6), Rhizopus species (n = 3), and Pseudallescheria boydii (n = 1). The isolates were identified to species levels by sequence analysis of the internal transcribed spacer (ITS) regions using primers ITS1 and ITS4. None of the 28 genetically well characterized isolates of P. marneffei were identified as P. marneffei by MALDI-TOF MS, because P. marneffei was not present in either Bruker general library (DB 5627) or Bruker filamentous fungi library V1.0. However, the rate of accurate identification as P. marneffei (score value ≥ 2.000) was 85.7% based on newly created database from one P. marneffei strain (NTUH-3370) by MALDI Biotyper system. Sequencing analysis of these 22 non-P. marneffei isolates of molds revealed seven Paecilomyces variotii, six F. solani, four Paecilomyces lilacinus, and one each of Paecilomyces sinensis, Rhizopus arrhizus, R. oryzae, R. microspores, and P. boydii. Although all the seven P. variotii isolates, four of the six F. solani, two of the four P. lilacinus, and two of the three isolates of Rhizopus species, and the P. boydii isolate had concordant identification results between MALDI-TOF MS and sequencing analysis, the score values of these isolates were all of <1.700. This study indicated that the MALDI Bruker Biotyper is ineffective for identifying P. marneffei and other unusual molds because of the current database limitations. Therefore, it is necessary to continuously update the MALDI-TOF MS databases. PMID:26217315
Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge
2017-05-04
Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures) were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA), Simultaneous Thermal analysis (STA), Laser Flash analysis (LFA), and Fourier Transform Infrared (FTIR) analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D) model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper). The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering.
ERIC Educational Resources Information Center
Mills, Myron L.
1988-01-01
A system developed for more efficient evaluation of graduate medical students' progress uses numerical scoring and a microcomputer database management system as an alternative to manual methods to produce accurate, objective, and meaningful summaries of resident evaluations. (Author/MSE)
THE ART OF DATA MINING THE MINEFIELDS OF TOXICITY DATABASES TO LINK CHEMISTRY TO BIOLOGY
Toxicity databases have a special role in predictive toxicology, providing ready access to historical information throughout the workflow of discovery, development, and product safety processes in drug development as well as in review by regulatory agencies. To provide accurate i...
WFPC2 Observations of Astrophysically Important Visual Binaries
NASA Astrophysics Data System (ADS)
Bond, Howard
1997-07-01
We recently used WFPC2 images of Procyon A and B to measure an extremely accurate separation of the bright F star and its much fainter white-dwarf companion. Combined with ground-based astrometry of the bright star, our observation significantly revises downward the derived masses, and brings Procyon A into excellent agreement with theoretical evolutionary tracks for the first time. We now propose to begin a modest but long-term program of WFPC2 measurements of astrophysically important visual binaries, working in a regime of large magnitude differences and/or faint stars where ground-based speckle interferometry cannot compete. We have selected three systems: Procyon {P=40 yr}, for which continued monitoring will even further refine the very accurate masses; Mu Cas {P=21 yr}, a famous metal-deficient G dwarf for which accurate masses will lead to the star's helium content with cosmological implications; and G 107-70, a close double white dwarf {P=18 yr} that promises to add two accurate masses to the tiny handful of white-dwarf masses that are directly known from dynamical measurements.
WFPC2 Observations of Astrophysically Important Visual Binaries - Continued
NASA Astrophysics Data System (ADS)
Bond, Howard
1999-07-01
We recently used WFPC2 images of Procyon A and B to measure an extremely accurate separation of the bright F star and its much fainter white-dwarf companion. Combined with ground-based astrometry of the bright star, our observation significantly revises downward the derived masses, and brings Procyon A into excellent agreement with theoretical evolutionary tracks for the first time. We now propose to begin a modest but long-term program of WFPC2 measurements of astrophysically important visual binaries, working in a regime of large magnitude differences and/or faint stars where ground-based speckle interferometry cannot compete. We have selected three systems: Procyon {P=40 yr}, for which continued monitoring will even further refine the very accurate masses; Mu Cas {P=21 yr}, a famous metal-deficient G dwarf for which accurate masses will lead to the star's helium content with cosmological implications; and G 107-70, a close double white dwarf {P=18 yr} that promises to add two accurate masses to the tiny handful of white-dwarf masses that are directly known from dynamical measurements.
Neutron induced fission of 237Np - status, challenges and opportunities
NASA Astrophysics Data System (ADS)
Ruskov, Ivan; Goverdovski, Andrei; Furman, Walter; Kopatch, Yury; Shcherbakov, Oleg; Hambsch, Franz-Josef; Oberstedt, Stephan; Oberstedt, Andreas
2018-03-01
Nowadays, there is an increased interest in a complete study of the neutron-induced fission of 237Np. This is due to the need of accurate and reliable nuclear data for nuclear science and technology. 237Np is generated (and accumulated) in the nuclear reactor core during reactor operation. As one of the most abundant long-lived isotopes in spent fuel ("waste"), the incineration of 237Np becomes an important issue. One scenario for burning of 237Np and other radio-toxic minor actinides suggests they are to be mixed into the fuel of future fast-neutron reactors, employing the so-called transmutation and partitioning technology. For testing present fission models, which are at the basis of new generation nuclear reactor developments, highly accurate and detailed neutron-induced nuclear reaction data is needed. However, the EXFOR nuclear database for 237Np on neutron-induced capture cross-section, σγ, and fission cross-section, σf, as well as on the characteristics of capture and fission resonance parameters (Γγ, Γf, σoΓf, fragments mass-energy yield distributions, multiplicities of neutrons vn and γ-rays vγ), has not been updated for decades.
NASA Astrophysics Data System (ADS)
Kawai, Soshi; Terashima, Hiroshi; Negishi, Hideyo
2015-11-01
This paper addresses issues in high-fidelity numerical simulations of transcritical turbulent flows at supercritical pressure. The proposed strategy builds on a tabulated look-up table method based on REFPROP database for an accurate estimation of non-linear behaviors of thermodynamic and fluid transport properties at the transcritical conditions. Based on the look-up table method we propose a numerical method that satisfies high-order spatial accuracy, spurious-oscillation-free property, and capability of capturing the abrupt variation in thermodynamic properties across the transcritical contact surface. The method introduces artificial mass diffusivity to the continuity and momentum equations in a physically-consistent manner in order to capture the steep transcritical thermodynamic variations robustly while maintaining spurious-oscillation-free property in the velocity field. The pressure evolution equation is derived from the full compressible Navier-Stokes equations and solved instead of solving the total energy equation to achieve the spurious pressure oscillation free property with an arbitrary equation of state including the present look-up table method. Flow problems with and without physical diffusion are employed for the numerical tests to validate the robustness, accuracy, and consistency of the proposed approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawai, Soshi, E-mail: kawai@cfd.mech.tohoku.ac.jp; Terashima, Hiroshi; Negishi, Hideyo
2015-11-01
This paper addresses issues in high-fidelity numerical simulations of transcritical turbulent flows at supercritical pressure. The proposed strategy builds on a tabulated look-up table method based on REFPROP database for an accurate estimation of non-linear behaviors of thermodynamic and fluid transport properties at the transcritical conditions. Based on the look-up table method we propose a numerical method that satisfies high-order spatial accuracy, spurious-oscillation-free property, and capability of capturing the abrupt variation in thermodynamic properties across the transcritical contact surface. The method introduces artificial mass diffusivity to the continuity and momentum equations in a physically-consistent manner in order to capture themore » steep transcritical thermodynamic variations robustly while maintaining spurious-oscillation-free property in the velocity field. The pressure evolution equation is derived from the full compressible Navier–Stokes equations and solved instead of solving the total energy equation to achieve the spurious pressure oscillation free property with an arbitrary equation of state including the present look-up table method. Flow problems with and without physical diffusion are employed for the numerical tests to validate the robustness, accuracy, and consistency of the proposed approach.« less
High-throughput non-targeted analyses (NTA) rely on chemical reference databases for tentative identification of observed chemical features. Many of these databases and online resources incorporate chemical structure data not in a form that is readily observed by mass spectromet...
Arc Jet Facility Test Condition Predictions Using the ADSI Code
NASA Technical Reports Server (NTRS)
Palmer, Grant; Prabhu, Dinesh; Terrazas-Salinas, Imelda
2015-01-01
The Aerothermal Design Space Interpolation (ADSI) tool is used to interpolate databases of previously computed computational fluid dynamic solutions for test articles in a NASA Ames arc jet facility. The arc jet databases are generated using an Navier-Stokes flow solver using previously determined best practices. The arc jet mass flow rates and arc currents used to discretize the database are chosen to span the operating conditions possible in the arc jet, and are based on previous arc jet experimental conditions where possible. The ADSI code is a database interpolation, manipulation, and examination tool that can be used to estimate the stagnation point pressure and heating rate for user-specified values of arc jet mass flow rate and arc current. The interpolation is performed in the other direction (predicting mass flow and current to achieve a desired stagnation point pressure and heating rate). ADSI is also used to generate 2-D response surfaces of stagnation point pressure and heating rate as a function of mass flow rate and arc current (or vice versa). Arc jet test data is used to assess the predictive capability of the ADSI code.
High-Order Methods for Computational Physics
1999-03-01
computation is running in 278 Ronald D. Henderson parallel. Instead we use the concept of a voxel database (VDB) of geometric positions in the mesh [85...processor 0 Fig. 4.19. Connectivity and communications axe established by building a voxel database (VDB) of positions. A VDB maps each position to a...studies such as the highly accurate stability computations considered help expand the database for this benchmark problem. The two-dimensional linear
Takahashi, Arata; Kumamaru, Hiraku; Tomotaki, Ai; Matsumura, Goki; Fukuchi, Eriko; Hirata, Yasutaka; Murakami, Arata; Hashimoto, Hideki; Ono, Minoru; Miyata, Hiroaki
2018-03-01
Japan Congenital Cardiovascluar Surgical Database (JCCVSD) is a nationwide registry whose data are used for health quality assessment and clinical research in Japan. We evaluated the completeness of case registration and the accuracy of recorded data components including postprocedural mortality and complications in the database via on-site data adjudication. We validated the records from JCCVSD 2010 to 2012 containing congenital cardiovascular surgery data performed in 111 facilities throughout Japan. We randomly chose nine facilities for site visit by the auditor team and conducted on-site data adjudication. We assessed whether the records in JCCVSD matched the data in the source materials. We identified 1,928 cases of eligible surgeries performed at the facilities, of which 1,910 were registered (99.1% completeness), with 6 cases of duplication and 1 inappropriate case registration. Data components including gender, age, and surgery time (hours) were highly accurate with 98% to 100% concordance. Mortality at discharge and at 30 and 90 postoperative days was 100% accurate. Among the five complications studied, reoperation was the most frequently observed, with 16 and 21 cases recorded in the database and source materials, respectively, having a sensitivity of 0.67 and a specificity of 0.99. Validation of JCCVSD database showed high registration completeness and high accuracy especially in the categorical data components. Adjudicated mortality was 100% accurate. While limited in numbers, the recorded cases of postoperative complications all had high specificities but had lower sensitivity (0.67-1.00). Continued activities for data quality improvement and assessment are necessary for optimizing the utility of these registries.
Advanced Mass Spectrometric Methods for the Rapid and Quantitative Characterization of Proteomes
Smith, Richard D.
2002-01-01
Progress is reviewedmore » towards the development of a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness and throughput of proteomic measurements based upon the use of high performance separations and mass spectrometry. The approach uses high accuracy mass measurements from Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate peptide ‘accurate mass tags’ (AMTs) produced by global protein enzymatic digestions for a specific organism, tissue or cell type from ‘potential mass tags’ tentatively identified using conventional tandem mass spectrometry (MS/MS). This provides the basis for subsequent measurements without the need for MS/ MS. High resolution capillary liquid chromatography separations combined with high sensitivity, and high resolution accurate FTICR measurements are shown to be capable of characterizing peptide mixtures of more than 10 5 components. The strategy has been initially demonstrated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, high sensitivity, and the capability for stableisotope labeling methods for precise relative protein abundance measurements. Abbreviations : LC, liquid chromatography; FTICR, Fourier transform ion cyclotron resonance; AMT, accurate mass tag; PMT, potential mass tag; MMA, mass measurement accuracy; MS, mass spectrometry; MS/MS, tandem mass spectrometry; ppm, parts per million.« less
Van Berkel, Gary J; Kertesz, Vilmos
2017-02-15
An "Open Access"-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendor-provided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. Using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. This work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.
Tan, Maxine; Pu, Jiantao; Zheng, Bin
2014-01-01
Purpose: Improving radiologists’ performance in classification between malignant and benign breast lesions is important to increase cancer detection sensitivity and reduce false-positive recalls. For this purpose, developing computer-aided diagnosis (CAD) schemes has been attracting research interest in recent years. In this study, we investigated a new feature selection method for the task of breast mass classification. Methods: We initially computed 181 image features based on mass shape, spiculation, contrast, presence of fat or calcifications, texture, isodensity, and other morphological features. From this large image feature pool, we used a sequential forward floating selection (SFFS)-based feature selection method to select relevant features, and analyzed their performance using a support vector machine (SVM) model trained for the classification task. On a database of 600 benign and 600 malignant mass regions of interest (ROIs), we performed the study using a ten-fold cross-validation method. Feature selection and optimization of the SVM parameters were conducted on the training subsets only. Results: The area under the receiver operating characteristic curve (AUC) = 0.805±0.012 was obtained for the classification task. The results also showed that the most frequently-selected features by the SFFS-based algorithm in 10-fold iterations were those related to mass shape, isodensity and presence of fat, which are consistent with the image features frequently used by radiologists in the clinical environment for mass classification. The study also indicated that accurately computing mass spiculation features from the projection mammograms was difficult, and failed to perform well for the mass classification task due to tissue overlap within the benign mass regions. Conclusions: In conclusion, this comprehensive feature analysis study provided new and valuable information for optimizing computerized mass classification schemes that may have potential to be useful as a “second reader” in future clinical practice. PMID:24664267
NASA Astrophysics Data System (ADS)
Ilavajhala, S.; Davies, D.; Schmaltz, J. E.; Wong, M.; Murphy, K. J.
2013-12-01
The NASA Fire Information for Resource Management System (FIRMS) is at the forefront of providing global near real-time (NRT) MODIS thermal anomalies / hotspot location data to end-users . FIRMS serves the data via an interactive Web GIS named Web Fire Mapper, downloads of NRT active fire, archive data downloads for MODIS hotspots dating back to 1999 and a hotspot email alert system The FIRMS Email Alerts system has been successfully alerting users of fires in their area of interest in near real-time and/or via daily and weekly email summaries, with an option to receive MODIS hotspot data as a text file (CSV) attachment. Currently, there are more than 7000 email alert subscriptions from more than 100 countries. Specifically, the email alerts system is designed to generate and send an email alert for any region or area on the globe, with a special focus on providing alerts for protected areas worldwide. For many protected areas, email alerts are particularly useful for early fire detection, monitoring on going fires, as well as allocating resources to protect wildlife and natural resources of particular value. For protected areas, FIRMS uses the World Database on Protected Areas (WDPA) supplied by United Nations Environment Program - World Conservation Monitoring Centre (UNEP-WCMC). Maintaining the most up-to-date, accurate boundary geometry for the protected areas for the email alerts is a challenge as the WDPA is continuously updated due to changing boundaries, merging or delisting of certain protected areas. Because of this dynamic nature of the protected areas database, the FIRMS protected areas database is frequently out-of-date with the most current version of WDPA database. To maintain the most up-to-date boundary information for protected areas and to be in compliance with the WDPA terms and conditions, FIRMS needs to constantly update its database of protected areas. Currently, FIRMS strives to keep its database up to date by downloading the most recent WDPA database at regular intervals, processing it, and ingesting it into the FIRMS spatial database. However, due to the large size of database, the process to download, process and ingest the database is quite time consuming. The FIRMS team is currently working on developing a method to update the protected areas database via web at regular intervals or on-demand. Using such a solution, FIRMS will be able access the most up-to-date extents of any protected area and the corresponding spatial geometries in real time. As such, FIRMS can utilize such a service to access the protected areas and their associated geometries to keep users' protected area boundaries in sync with those of the most recent WDPA database, and thus serve a more accurate email alert to the users. Furthermore, any client accessing the WDPA protected areas database could potentially use the solution of real-time access to the protected areas database. This talk primarily focuses on the challenges for FIRMS in sending accurate email alerts for protected areas, along with the solution the FIRMS team is developing. This talk also introduces the FIRMS fire information system and its components, with a special emphasis on the FIRMS email alerts system.
The volatile compound BinBase mass spectral database.
Skogerson, Kirsten; Wohlgemuth, Gert; Barupal, Dinesh K; Fiehn, Oliver
2011-08-04
Volatile compounds comprise diverse chemical groups with wide-ranging sources and functions. These compounds originate from major pathways of secondary metabolism in many organisms and play essential roles in chemical ecology in both plant and animal kingdoms. In past decades, sampling methods and instrumentation for the analysis of complex volatile mixtures have improved; however, design and implementation of database tools to process and store the complex datasets have lagged behind. The volatile compound BinBase (vocBinBase) is an automated peak annotation and database system developed for the analysis of GC-TOF-MS data derived from complex volatile mixtures. The vocBinBase DB is an extension of the previously reported metabolite BinBase software developed to track and identify derivatized metabolites. The BinBase algorithm uses deconvoluted spectra and peak metadata (retention index, unique ion, spectral similarity, peak signal-to-noise ratio, and peak purity) from the Leco ChromaTOF software, and annotates peaks using a multi-tiered filtering system with stringent thresholds. The vocBinBase algorithm assigns the identity of compounds existing in the database. Volatile compound assignments are supported by the Adams mass spectral-retention index library, which contains over 2,000 plant-derived volatile compounds. Novel molecules that are not found within vocBinBase are automatically added using strict mass spectral and experimental criteria. Users obtain fully annotated data sheets with quantitative information for all volatile compounds for studies that may consist of thousands of chromatograms. The vocBinBase database may also be queried across different studies, comprising currently 1,537 unique mass spectra generated from 1.7 million deconvoluted mass spectra of 3,435 samples (18 species). Mass spectra with retention indices and volatile profiles are available as free download under the CC-BY agreement (http://vocbinbase.fiehnlab.ucdavis.edu). The BinBase database algorithms have been successfully modified to allow for tracking and identification of volatile compounds in complex mixtures. The database is capable of annotating large datasets (hundreds to thousands of samples) and is well-suited for between-study comparisons such as chemotaxonomy investigations. This novel volatile compound database tool is applicable to research fields spanning chemical ecology to human health. The BinBase source code is freely available at http://binbase.sourceforge.net/ under the LGPL 2.0 license agreement.
The volatile compound BinBase mass spectral database
2011-01-01
Background Volatile compounds comprise diverse chemical groups with wide-ranging sources and functions. These compounds originate from major pathways of secondary metabolism in many organisms and play essential roles in chemical ecology in both plant and animal kingdoms. In past decades, sampling methods and instrumentation for the analysis of complex volatile mixtures have improved; however, design and implementation of database tools to process and store the complex datasets have lagged behind. Description The volatile compound BinBase (vocBinBase) is an automated peak annotation and database system developed for the analysis of GC-TOF-MS data derived from complex volatile mixtures. The vocBinBase DB is an extension of the previously reported metabolite BinBase software developed to track and identify derivatized metabolites. The BinBase algorithm uses deconvoluted spectra and peak metadata (retention index, unique ion, spectral similarity, peak signal-to-noise ratio, and peak purity) from the Leco ChromaTOF software, and annotates peaks using a multi-tiered filtering system with stringent thresholds. The vocBinBase algorithm assigns the identity of compounds existing in the database. Volatile compound assignments are supported by the Adams mass spectral-retention index library, which contains over 2,000 plant-derived volatile compounds. Novel molecules that are not found within vocBinBase are automatically added using strict mass spectral and experimental criteria. Users obtain fully annotated data sheets with quantitative information for all volatile compounds for studies that may consist of thousands of chromatograms. The vocBinBase database may also be queried across different studies, comprising currently 1,537 unique mass spectra generated from 1.7 million deconvoluted mass spectra of 3,435 samples (18 species). Mass spectra with retention indices and volatile profiles are available as free download under the CC-BY agreement (http://vocbinbase.fiehnlab.ucdavis.edu). Conclusions The BinBase database algorithms have been successfully modified to allow for tracking and identification of volatile compounds in complex mixtures. The database is capable of annotating large datasets (hundreds to thousands of samples) and is well-suited for between-study comparisons such as chemotaxonomy investigations. This novel volatile compound database tool is applicable to research fields spanning chemical ecology to human health. The BinBase source code is freely available at http://binbase.sourceforge.net/ under the LGPL 2.0 license agreement. PMID:21816034
USDA-ARS?s Scientific Manuscript database
Because less than one-third of clinically relevant fusaria can be accurately identified to species level using phenotypic data (i.e., morphological species recognition), we constructed a three-locus DNA sequence database to facilitate molecular identification of the 69 Fusarium species associated wi...
Omasits, Ulrich; Varadarajan, Adithi R; Schmid, Michael; Goetze, Sandra; Melidis, Damianos; Bourqui, Marc; Nikolayeva, Olga; Québatte, Maxime; Patrignani, Andrea; Dehio, Christoph; Frey, Juerg E; Robinson, Mark D; Wollscheid, Bernd; Ahrens, Christian H
2017-12-01
Accurate annotation of all protein-coding sequences (CDSs) is an essential prerequisite to fully exploit the rapidly growing repertoire of completely sequenced prokaryotic genomes. However, large discrepancies among the number of CDSs annotated by different resources, missed functional short open reading frames (sORFs), and overprediction of spurious ORFs represent serious limitations. Our strategy toward accurate and complete genome annotation consolidates CDSs from multiple reference annotation resources, ab initio gene prediction algorithms and in silico ORFs (a modified six-frame translation considering alternative start codons) in an integrated proteogenomics database (iPtgxDB) that covers the entire protein-coding potential of a prokaryotic genome. By extending the PeptideClassifier concept of unambiguous peptides for prokaryotes, close to 95% of the identifiable peptides imply one distinct protein, largely simplifying downstream analysis. Searching a comprehensive Bartonella henselae proteomics data set against such an iPtgxDB allowed us to unambiguously identify novel ORFs uniquely predicted by each resource, including lipoproteins, differentially expressed and membrane-localized proteins, novel start sites and wrongly annotated pseudogenes. Most novelties were confirmed by targeted, parallel reaction monitoring mass spectrometry, including unique ORFs and single amino acid variations (SAAVs) identified in a re-sequenced laboratory strain that are not present in its reference genome. We demonstrate the general applicability of our strategy for genomes with varying GC content and distinct taxonomic origin. We release iPtgxDBs for B. henselae , Bradyrhizobium diazoefficiens and Escherichia coli and the software to generate both proteogenomics search databases and integrated annotation files that can be viewed in a genome browser for any prokaryote. © 2017 Omasits et al.; Published by Cold Spring Harbor Laboratory Press.
MALDI-TOF MS versus VITEK 2 ANC card for identification of anaerobic bacteria.
Li, Yang; Gu, Bing; Liu, Genyan; Xia, Wenying; Fan, Kun; Mei, Yaning; Huang, Peijun; Pan, Shiyang
2014-05-01
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an accurate, rapid and inexpensive technique that has initiated a revolution in the clinical microbiology laboratory for identification of pathogens. The Vitek 2 anaerobe and Corynebacterium (ANC) identification card is a newly developed method for identification of corynebacteria and anaerobic species. The aim of this study was to evaluate the effectiveness of the ANC card and MALDI-TOF MS techniques for identification of clinical anaerobic isolates. Five reference strains and a total of 50 anaerobic bacteria clinical isolates comprising ten different genera and 14 species were identified and analyzed by the ANC card together with Vitek 2 identification system and Vitek MS together with version 2.0 database respectively. 16S rRNA gene sequencing was used as reference method for accuracy in the identification. Vitek 2 ANC card and Vitek MS provided comparable results at species level for the five reference strains. Of 50 clinical strains, the Vitek MS provided identification for 46 strains (92%) to the species level, 47 (94%) to genus level, one (2%) low discrimination, two (4%) no identification and one (2%) misidentification. The Vitek 2 ANC card provided identification for 43 strains (86%) correct to the species level, 47 (94%) correct to the genus level, three (6%) low discrimination, three (6%) no identification and one (2%) misidentification. Both Vitek MS and Vitek 2 ANC card can be used for accurate routine clinical anaerobe identification. Comparing to the Vitek 2 ANC card, Vitek MS is easier, faster and more economic for each test. The databases currently available for both systems should be updated and further developed to enhance performance.
Martínez Bueno, María Jesús; Díaz-Galiano, Francisco José; Rajski, Łukasz; Cutillas, Víctor; Fernández-Alba, Amadeo R
2018-04-20
In the last decade, the consumption trend of organic food has increased dramatically worldwide. However, the lack of reliable chemical markers to discriminate between organic and conventional products makes this market susceptible to food fraud in products labeled as "organic". Metabolomic fingerprinting approach has been demonstrated as the best option for a full characterization of metabolome occurring in plants, since their pattern may reflect the impact of both endogenous and exogenous factors. In the present study, advanced technologies based on high performance liquid chromatography-high-resolution accurate mass spectrometry (HPLC-HRAMS) has been used for marker search in organic and conventional tomatoes grown in greenhouse under controlled agronomic conditions. The screening of unknown compounds comprised the retrospective analysis of all tomato samples throughout the studied period and data processing using databases (mzCloud, ChemSpider and PubChem). In addition, stable nitrogen isotope analysis (δ 15 N) was assessed as a possible indicator to support discrimination between both production systems using crop/fertilizer correlations. Pesticide residue analyses were also applied as a well-established way to evaluate the organic production. Finally, the evaluation by combined chemometric analysis of high-resolution accurate mass spectrometry (HRAMS) and δ 15 N data provided a robust classification model in accordance with the agricultural practices. Principal component analysis (PCA) showed a sample clustering according to farming systems and significant differences in the sample profile was observed for six bioactive components (L-tyrosyl-L-isoleucyl-L-threonyl-L-threonine, trilobatin, phloridzin, tomatine, phloretin and echinenone). Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Topping, David; Allan, James; Alfarra, Rami; Aumont, Bernard
2017-04-01
Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA) formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS) are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and O:C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof of concept study, the ability to train supervised methods to predict electron impact ionisation (EI) mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS), is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m/z) channels are fit as a function of molecular structure before the relative peak height for each channel is similarly fit using a range of regression methods. The widely-used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Initial results suggest the generic public 'MACCS' fingerprints provide the most accurate trained model when combined with both decision trees and random forests with median cosine angles of 0.94-.0.97 between modelled and measured spectra. There is some sensitivity to choice of fingerprint, but most sensitivity is in choice of regression technique. Support Vector Machines perform the worst, with median values of 0.78-0.85 and lower ranges approaching 0.4 depending on the fingerprint used. More detailed analysis of modelled versus mass spectra demonstrates important composition dependent sensitivities on a compound-by-compound basis. This is further demonstrated when we apply the trained methods to a model α-pinene SOA system, using output from the GECKO-A model. This shows that use of a generic fingerprint referred to as 'FP4' and one designed for vapour pressure predictions ('Nanoolal') give plausible mass spectra, whilst the use of the MACCS keys perform poorly in this application, demonstrating the need for evaluating model performance against other SOA systems rather than existing laboratory databases on single compounds.
Application of kernel functions for accurate similarity search in large chemical databases.
Wang, Xiaohong; Huan, Jun; Smalter, Aaron; Lushington, Gerald H
2010-04-29
Similarity search in chemical structure databases is an important problem with many applications in chemical genomics, drug design, and efficient chemical probe screening among others. It is widely believed that structure based methods provide an efficient way to do the query. Recently various graph kernel functions have been designed to capture the intrinsic similarity of graphs. Though successful in constructing accurate predictive and classification models, graph kernel functions can not be applied to large chemical compound database due to the high computational complexity and the difficulties in indexing similarity search for large databases. To bridge graph kernel function and similarity search in chemical databases, we applied a novel kernel-based similarity measurement, developed in our team, to measure similarity of graph represented chemicals. In our method, we utilize a hash table to support new graph kernel function definition, efficient storage and fast search. We have applied our method, named G-hash, to large chemical databases. Our results show that the G-hash method achieves state-of-the-art performance for k-nearest neighbor (k-NN) classification. Moreover, the similarity measurement and the index structure is scalable to large chemical databases with smaller indexing size, and faster query processing time as compared to state-of-the-art indexing methods such as Daylight fingerprints, C-tree and GraphGrep. Efficient similarity query processing method for large chemical databases is challenging since we need to balance running time efficiency and similarity search accuracy. Our previous similarity search method, G-hash, provides a new way to perform similarity search in chemical databases. Experimental study validates the utility of G-hash in chemical databases.
Liu, Zhao-Ying; Huang, Ling-Li; Chen, Dong-Mei; Dai, Meng-Hong; Tao, Yan-Fei; Wang, Yu-Lian; Yuan, Zong-Hui
2010-02-01
The application of electrospray ionization hybrid ion trap/time-of-flight mass spectrometry coupled with high-performance liquid chromatography (LC/MS-IT-TOF) in the rapid characterization of in vitro metabolites of quinocetone was developed. Metabolites formed in rat liver microsomes were separated using a VP-ODS column with gradient elution. Multiple scans of metabolites in MS and MS(2) modes and accurate mass measurements were automatically performed simultaneously through data-dependent acquisition in only a 30-min analysis. Most measured mass errors were less than 10 ppm for both protonated molecules and fragment ions using external mass calibration. The elemental compositions of all fragment ions of quinocetone and its metabolites could be rapidly assigned based upon the known compositional elements of protonated molecules. The structure of metabolites were elucidated based on the combination of three techniques: agreement between their proposed structure, the accurate masses, and the elemental composition of ions in their mass spectra; comparison of their changes in accurate molecular masses and fragment ions with those of parent drug or metabolite; and the elemental compositions of lost mass numbers in proposed fragmentation pathways. Twenty-seven phase I metabolites were identified as 11 reduction metabolites, three direct hydroxylation metabolites, and 13 metabolites with a combination of reduction and hydroxylation. All metabolites except the N-oxide reduction metabolite M6 are new metabolites of quinocetone, which were not previously reported. The ability to conduct expected biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurement, all in a single experimental run, is one of the most attractive features of this methodology. The results demonstrate the use of LC/MS-IT-TOF approach appears to be rapid, efficient, and reliable in structural characterization of drug metabolites.
A review of automatic mass detection and segmentation in mammographic images.
Oliver, Arnau; Freixenet, Jordi; Martí, Joan; Pérez, Elsa; Pont, Josep; Denton, Erika R E; Zwiggelaar, Reyer
2010-04-01
The aim of this paper is to review existing approaches to the automatic detection and segmentation of masses in mammographic images, highlighting the key-points and main differences between the used strategies. The key objective is to point out the advantages and disadvantages of the various approaches. In contrast with other reviews which only describe and compare different approaches qualitatively, this review also provides a quantitative comparison. The performance of seven mass detection methods is compared using two different mammographic databases: a public digitised database and a local full-field digital database. The results are given in terms of Receiver Operating Characteristic (ROC) and Free-response Receiver Operating Characteristic (FROC) analysis. Copyright 2009 Elsevier B.V. All rights reserved.
Design and Implementation of an Intelligence Database.
1984-12-01
In designing SDM, many database aplications were analyzed in order to determine the structures that cc. i:r and recur in them...automatically, nor is it even known which relations can be converted to Di./NF. In spite of this, DK/NF can be exceedingly useful for practical database...goal of any design process is to produce qn output design, Sout, to accurately represent Sin. Further . all the relations in Sout must satisfy
Opportune Landing Site CBR and Low-Density Laboratory Database
2008-05-01
Program Opportune Landing Site CBR and Low- Density Laboratory Database Larry S. Danyluk, Sally A. Shoop, Rosa T. Affleck, and Wendy L. Wieder...Opportune Landing Site Program ERDC/CRREL TR-08-9 May 2008 Opportune Landing Site CBR and Low- Density Laboratory Database Larry S. Danyluk, Sally A...reproduce in-situ density , moisture, and CBR values and therefore do not accurately repre- sent the complete range of these values measured in the field
Wieme, Anneleen D; Spitaels, Freek; Aerts, Maarten; De Bruyne, Katrien; Van Landschoot, Anita; Vandamme, Peter
2014-08-18
Applicability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identification of beer-spoilage bacteria was examined. To achieve this, an extensive identification database was constructed comprising more than 4200 mass spectra, including biological and technical replicates derived from 273 acetic acid bacteria (AAB) and lactic acid bacteria (LAB), covering a total of 52 species, grown on at least three growth media. Sequence analysis of protein coding genes was used to verify aberrant MALDI-TOF MS identification results and confirmed the earlier misidentification of 34 AAB and LAB strains. In total, 348 isolates were collected from culture media inoculated with 14 spoiled beer and brewery samples. Peak-based numerical analysis of MALDI-TOF MS spectra allowed a straightforward species identification of 327 (94.0%) isolates. The remaining isolates clustered separately and were assigned through sequence analysis of protein coding genes either to species not known as beer-spoilage bacteria, and thus not present in the database, or to novel AAB species. An alternative, classifier-based approach for the identification of spoilage bacteria was evaluated by combining the identification results obtained through peak-based cluster analysis and sequence analysis of protein coding genes as a standard. In total, 263 out of 348 isolates (75.6%) were correctly identified at species level and 24 isolates (6.9%) were misidentified. In addition, the identification results of 50 isolates (14.4%) were considered unreliable, and 11 isolates (3.2%) could not be identified. The present study demonstrated that MALDI-TOF MS is well-suited for the rapid, high-throughput and accurate identification of bacteria isolated from spoiled beer and brewery samples, which makes the technique appropriate for routine microbial quality control in the brewing industry. Copyright © 2014 Elsevier B.V. All rights reserved.
Measuring Intermediate-Mass Black-Hole Binaries with Advanced Gravitational Wave Detectors.
Veitch, John; Pürrer, Michael; Mandel, Ilya
2015-10-02
We perform a systematic study to explore the accuracy with which the parameters of intermediate-mass black-hole binary systems can be measured from their gravitational wave (GW) signatures using second-generation GW detectors. We make use of the most recent reduced-order models containing inspiral, merger, and ringdown signals of aligned-spin effective-one-body waveforms to significantly speed up the calculations. We explore the phenomenology of the measurement accuracies for binaries with total masses between 50M(⊙) and 500M(⊙) and mass ratios between 0.1 and 1. We find that (i) at total masses below ∼200M(⊙), where the signal-to-noise ratio is dominated by the inspiral portion of the signal, the chirp mass parameter can be accurately measured; (ii) at higher masses, the information content is dominated by the ringdown, and total mass is measured more accurately; (iii) the mass of the lower-mass companion is poorly estimated, especially at high total mass and more extreme mass ratios; and (iv) spin cannot be accurately measured for our injection set with nonspinning components. Most importantly, we find that for binaries with nonspinning components at all values of the mass ratio in the considered range and at a network signal-to-noise ratio of 15, analyzed with spin-aligned templates, the presence of an intermediate-mass black hole with mass >100M(⊙) can be confirmed with 95% confidence in any binary that includes a component with a mass of 130M(⊙) or greater.
Changes in body composition of neonatal piglets during growth
USDA-ARS?s Scientific Manuscript database
During studies of neonatal piglet growth it is important to be able to accurately assess changes in body composition. Previous studies have demonstrated that quantitative magnetic resonance (QMR) provides precise and accurate measurements of total body fat mass, lean mass and total body water in non...
Griffiths, Nia W; Wyatt, Mark F; Kean, Suzanna D; Graham, Andrew E; Stein, Bridget K; Brenton, A Gareth
2010-06-15
A method for the accurate mass measurement of positive radical ions by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) is described. Initial use of a conjugated oligomeric calibration material was rejected in favour of a series of meso-tetraalkyl/tetraalkylaryl-functionalised porphyrins, from which the two calibrants required for a particular accurate mass measurement were chosen. While all measurements of monoisotopic species were within +/-5 ppm, and the method was rigorously validated using chemometrics, mean values of five measurements were used for extra confidence in the generation of potential elemental formulae. Potential difficulties encountered when measuring compounds containing multi-isotopic elements are discussed, where the monoisotopic peak is no longer the lowest mass peak, and a simple mass-correction solution can be applied. The method requires no significant expertise to implement, but care and attention is required to obtain valid measurements. The method is operationally simple and will prove useful to the analytical chemistry community. Copyright (c) 2010 John Wiley & Sons, Ltd.
Antarctic mass balance changes from GRACE
NASA Astrophysics Data System (ADS)
Kallenberg, B.; Tregoning, P.
2012-04-01
The Antarctic ice sheet contains ~30 million km3 of ice and constitutes a significant component of the global water balance with enough freshwater to raise global sea level by ~60 m. Altimetry measurements and climate models suggest variable behaviour across the Antarctic ice sheet, with thickening occurring in a vast area of East Antarctica and substantial thinning in West Antarctica caused by increased temperature gradients in the surrounding ocean. However, the rate at which the polar ice cap is melting is still poorly constrained. To calculate the mass loss of an ice sheet it is necessary to separate present day mass balance changes from glacial isostatic adjustment (GIA), the response of the Earth's crust to mass loss, wherefore it is essential to undertake sufficient geological and geomorphological sampling. As there is only a limited possibility for this in Antarctica, all models (i.e. geological, hydrological as well as atmospheric) are very poorly constrained. Therefore, space-geodetic observations play an important role in detecting changes in mass and spatial variations in the Earth's gravity field. The Gravity Recovery And Climate Experiment (GRACE) observed spatial variations in the Earth's gravity field over the past ten years. The satellite detects mass variations in the Earth system including geophysical, hydrological and atmospheric shifts. GRACE itself is not able to separate the GIA from mass balance changes and, due to the insufficient geological and geomorphological database, it is not possible to model the GIA effect accurately for Antarctica. However, the results from GRACE can be compared with other scientific results, coming from other geodetic observations such as satellite altimetry and GPS or by the use of geological observations. In our contribution we compare the GRACE data with recorded precipitation patterns and mass anomalies over East Antarctica to separate the observed GRACE signal into its two components: GIA as a result of mass loss and present day surface load changes due to possible snow/ice accumulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baer, M.R.; Hobbs, M.L.; McGee, B.C.
Exponential-13,6 (EXP-13,6) potential pammeters for 750 gases composed of 48 elements were determined and assembled in a database, referred to as the JCZS database, for use with the Jacobs Cowperthwaite Zwisler equation of state (JCZ3-EOS)~l) The EXP- 13,6 force constants were obtained by using literature values of Lennard-Jones (LJ) potential functions, by using corresponding states (CS) theory, by matching pure liquid shock Hugoniot data, and by using molecular volume to determine the approach radii with the well depth estimated from high-pressure isen- tropes. The JCZS database was used to accurately predict detonation velocity, pressure, and temperature for 50 dif- 3more » Accurate predictions were also ferent explosives with initial densities ranging from 0.25 glcm3 to 1.97 g/cm . obtained for pure liquid shock Hugoniots, static properties of nitrogen, and gas detonations at high initial pressures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borghesi, Giulio; Bellan, Josette, E-mail: josette.bellan@jpl.nasa.gov; Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109-8099
2015-03-15
A Direct Numerical Simulation (DNS) database was created representing mixing of species under high-pressure conditions. The configuration considered is that of a temporally evolving mixing layer. The database was examined and analyzed for the purpose of modeling some of the unclosed terms that appear in the Large Eddy Simulation (LES) equations. Several metrics are used to understand the LES modeling requirements. First, a statistical analysis of the DNS-database large-scale flow structures was performed to provide a metric for probing the accuracy of the proposed LES models as the flow fields obtained from accurate LESs should contain structures of morphology statisticallymore » similar to those observed in the filtered-and-coarsened DNS (FC-DNS) fields. To characterize the morphology of the large-scales structures, the Minkowski functionals of the iso-surfaces were evaluated for two different fields: the second-invariant of the rate of deformation tensor and the irreversible entropy production rate. To remove the presence of the small flow scales, both of these fields were computed using the FC-DNS solutions. It was found that the large-scale structures of the irreversible entropy production rate exhibit higher morphological complexity than those of the second invariant of the rate of deformation tensor, indicating that the burden of modeling will be on recovering the thermodynamic fields. Second, to evaluate the physical effects which must be modeled at the subfilter scale, an a priori analysis was conducted. This a priori analysis, conducted in the coarse-grid LES regime, revealed that standard closures for the filtered pressure, the filtered heat flux, and the filtered species mass fluxes, in which a filtered function of a variable is equal to the function of the filtered variable, may no longer be valid for the high-pressure flows considered in this study. The terms requiring modeling are the filtered pressure, the filtered heat flux, the filtered pressure work, and the filtered species mass fluxes. Improved models were developed based on a scale-similarity approach and were found to perform considerably better than the classical ones. These improved models were also assessed in an a posteriori study. Different combinations of the standard models and the improved ones were tested. At the relatively small Reynolds numbers achievable in DNS and at the relatively small filter widths used here, the standard models for the filtered pressure, the filtered heat flux, and the filtered species fluxes were found to yield accurate results for the morphology of the large-scale structures present in the flow. Analysis of the temporal evolution of several volume-averaged quantities representative of the mixing layer growth, and of the cross-stream variation of homogeneous-plane averages and second-order correlations, as well as of visualizations, indicated that the models performed equivalently for the conditions of the simulations. The expectation is that at the much larger Reynolds numbers and much larger filter widths used in practical applications, the improved models will have much more accurate performance than the standard one.« less
Proteomic Identification of Monoclonal Antibodies from Serum
2015-01-01
Characterizing the in vivo dynamics of the polyclonal antibody repertoire in serum, such as that which might arise in response to stimulation with an antigen, is difficult due to the presence of many highly similar immunoglobulin proteins, each specified by distinct B lymphocytes. These challenges have precluded the use of conventional mass spectrometry for antibody identification based on peptide mass spectral matches to a genomic reference database. Recently, progress has been made using bottom-up analysis of serum antibodies by nanoflow liquid chromatography/high-resolution tandem mass spectrometry combined with a sample-specific antibody sequence database generated by high-throughput sequencing of individual B cell immunoglobulin variable domains (V genes). Here, we describe how intrinsic features of antibody primary structure, most notably the interspersed segments of variable and conserved amino acid sequences, generate recurring patterns in the corresponding peptide mass spectra of V gene peptides, greatly complicating the assignment of correct sequences to mass spectral data. We show that the standard method of decoy-based error modeling fails to account for the error introduced by these highly similar sequences, leading to a significant underestimation of the false discovery rate. Because of these effects, antibody-derived peptide mass spectra require increased stringency in their interpretation. The use of filters based on the mean precursor ion mass accuracy of peptide-spectrum matches is shown to be particularly effective in distinguishing between “true” and “false” identifications. These findings highlight important caveats associated with the use of standard database search and error-modeling methods with nonstandard data sets and custom sequence databases. PMID:24684310
NASA Technical Reports Server (NTRS)
Steck, Daniel
2009-01-01
This report documents the generation of an outbound Earth to Moon transfer preliminary database consisting of four cases calculated twice a day for a 19 year period. The database was desired as the first step in order for NASA to rapidly generate Earth to Moon trajectories for the Constellation Program using the Mission Assessment Post Processor. The completed database was created running a flight trajectory and optimization program, called Copernicus, in batch mode with the use of newly created Matlab functions. The database is accurate and has high data resolution. The techniques and scripts developed to generate the trajectory information will also be directly used in generating a comprehensive database.
Fast and accurate mock catalogue generation for low-mass galaxies
NASA Astrophysics Data System (ADS)
Koda, Jun; Blake, Chris; Beutler, Florian; Kazin, Eyal; Marin, Felipe
2016-06-01
We present an accurate and fast framework for generating mock catalogues including low-mass haloes, based on an implementation of the COmoving Lagrangian Acceleration (COLA) technique. Multiple realisations of mock catalogues are crucial for analyses of large-scale structure, but conventional N-body simulations are too computationally expensive for the production of thousands of realizations. We show that COLA simulations can produce accurate mock catalogues with a moderate computation resource for low- to intermediate-mass galaxies in 1012 M⊙ haloes, both in real and redshift space. COLA simulations have accurate peculiar velocities, without systematic errors in the velocity power spectra for k ≤ 0.15 h Mpc-1, and with only 3-per cent error for k ≤ 0.2 h Mpc-1. We use COLA with 10 time steps and a Halo Occupation Distribution to produce 600 mock galaxy catalogues of the WiggleZ Dark Energy Survey. Our parallelized code for efficient generation of accurate halo catalogues is publicly available at github.com/junkoda/cola_halo.
Yu, Xiaoxue; Zhang, Yafeng; Wang, Dongmei; Jiang, Lin; Xu, Xinjun
2018-01-01
Background: Citri Reticulatae Pericarpium is the dried mature pericarp of Citrus reticulata Blanco which can be divided into “Chenpi” and “Guangchenpi.” “Guangchenpi” is the genuine Chinese medicinal material in Xinhui, Guangdong province; based on the greatest quality and least amount, it is most expensive among others. Hesperidin is used as the marker to identify Citri Reticulatae Pericarpium described in the Chinese Pharmacopoeia 2010. However, both “Chenpi” and “Guangchenpi” contain hesperidin so that it is impossible to differentiate them by measuring hesperidin. Objective: Our study aims to develop an efficient and accurate method to separate and identify “Guangchenpi” from other Citri Reticulatae Pericarpium. Materials and Methods: The genomic deoxyribonucleic acid (DNA) of all the materials was extracted and then the internal transcribed spacer 2 was amplified, sequenced, aligned, and analyzed. The secondary structures were created in terms of the database and website established by Jörg Schultz et al. High-performance liquid chromatography-diode array detection-electrospray Ionization/mass spectrometry (HPLC-DAD-ESI-MS)/MS coupled with chemometric analysis was applied to compare the differences in chemical profiles of the three kinds of Citri Reticulatae Pericarpium. Results: A total of 22 samples were classified into three groups. The results of DNA barcoding were in accordance with principal component analysis and hierarchical cluster analysis. Eight compounds were deduced from HPLC-DAD-ESI-MS/MS. Conclusions: This method is a reliable and effective tool to differentiate the three Citri Reticulatae Pericarpium. SUMMARY The internal transcribed spacer 2 regions and the secondary structure among three kinds of Citri Reticulatae Pericarpium varied considerablyAll the 22 samples were analyzed by high-performance liquid chromatography (HPLC) to obtain the chemical profilesPrincipal component analysis and hierarchical cluster analysis were used in the chemometric analysisdeoxyribonucleic acid barcoding and HPLC-diode array detection-electrospray ionization/mass spectrometry/MS coupled with chemometric analysis provided an accurate and strong proof to identify these three herbs. Abbreviations used: CTAB: Hexadecyltrimethylammonium bromide, DNA: Deoxyribonucleic acid, ITS2: Internal transcribed spacer 2, PCR: Polymerase chain reaction. PMID:29576703
Dhiman, Neelam; Hall, Leslie; Wohlfiel, Sherri L; Buckwalter, Seanne P; Wengenack, Nancy L
2011-04-01
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry was compared to phenotypic testing for yeast identification. MALDI-TOF mass spectrometry yielded 96.3% and 84.5% accurate species level identifications (spectral scores, ≥ 1.8) for 138 common and 103 archived strains of yeast. MALDI-TOF mass spectrometry is accurate, rapid (5.1 min of hands-on time/identification), and cost-effective ($0.50/sample) for yeast identification in the clinical laboratory.
al-Owais, A.; al-Suwaidi, K.; Amiri, N.; Carter, A. O.; Hossain, M. M.; Sheek-Hussein, M. M.
2000-01-01
INTRODUCTION: Hepatitis B is of major public health importance. Accurate information on its occurrence, with particular reference to the prevalence of immunity and chronic infection (marked by the presence of hepatitis B core antibody and surface antigen, respectively, in serum), is essential for planning public health programmes for the control of the disease. The generation of marker prevalence data through serological surveys is costly and time-consuming. The present study in Al Ain Medical District, United Arab Emirates, investigated the possibility of obtaining sufficiently accurate marker prevalence estimates from existing data to plan public health programmes. METHODS: Two antenatal screening databases, one student serological survey database, one immunization programme database and one pre-marriage screening database containing information on marker prevalence were identified. Epidemiological data were abstracted from these databases and analysed. RESULTS: The data showed that the prevalence of hepatitis B surface antigen and the prevalence of core antibody in young citizens in 1998 were approximately 2% and 14% respectively, that any immunization campaign aimed at citizens of the United Arab Emirates should target teenagers as they had the highest risk of acquiring the disease, and that pre-immunization screening of young adults would be wasteful. However, the data did not yield information on the prevalence of hepatitis B surface antigen and core antibody in other population subgroups of public health significance. DISCUSSION: While data generated by the study are sufficient to support a hepatitis B immunization programme targeted at teenaged citizens, more accurate data, generated by a well-designed serological survey, would be essential for optimal public health planning. PMID:11143192
Rapid Identification of Sequences for Orphan Enzymes to Power Accurate Protein Annotation
Ojha, Sunil; Watson, Douglas S.; Bomar, Martha G.; Galande, Amit K.; Shearer, Alexander G.
2013-01-01
The power of genome sequencing depends on the ability to understand what those genes and their proteins products actually do. The automated methods used to assign functions to putative proteins in newly sequenced organisms are limited by the size of our library of proteins with both known function and sequence. Unfortunately this library grows slowly, lagging well behind the rapid increase in novel protein sequences produced by modern genome sequencing methods. One potential source for rapidly expanding this functional library is the “back catalog” of enzymology – “orphan enzymes,” those enzymes that have been characterized and yet lack any associated sequence. There are hundreds of orphan enzymes in the Enzyme Commission (EC) database alone. In this study, we demonstrate how this orphan enzyme “back catalog” is a fertile source for rapidly advancing the state of protein annotation. Starting from three orphan enzyme samples, we applied mass-spectrometry based analysis and computational methods (including sequence similarity networks, sequence and structural alignments, and operon context analysis) to rapidly identify the specific sequence for each orphan while avoiding the most time- and labor-intensive aspects of typical sequence identifications. We then used these three new sequences to more accurately predict the catalytic function of 385 previously uncharacterized or misannotated proteins. We expect that this kind of rapid sequence identification could be efficiently applied on a larger scale to make enzymology’s “back catalog” another powerful tool to drive accurate genome annotation. PMID:24386392
Rapid identification of sequences for orphan enzymes to power accurate protein annotation.
Ramkissoon, Kevin R; Miller, Jennifer K; Ojha, Sunil; Watson, Douglas S; Bomar, Martha G; Galande, Amit K; Shearer, Alexander G
2013-01-01
The power of genome sequencing depends on the ability to understand what those genes and their proteins products actually do. The automated methods used to assign functions to putative proteins in newly sequenced organisms are limited by the size of our library of proteins with both known function and sequence. Unfortunately this library grows slowly, lagging well behind the rapid increase in novel protein sequences produced by modern genome sequencing methods. One potential source for rapidly expanding this functional library is the "back catalog" of enzymology--"orphan enzymes," those enzymes that have been characterized and yet lack any associated sequence. There are hundreds of orphan enzymes in the Enzyme Commission (EC) database alone. In this study, we demonstrate how this orphan enzyme "back catalog" is a fertile source for rapidly advancing the state of protein annotation. Starting from three orphan enzyme samples, we applied mass-spectrometry based analysis and computational methods (including sequence similarity networks, sequence and structural alignments, and operon context analysis) to rapidly identify the specific sequence for each orphan while avoiding the most time- and labor-intensive aspects of typical sequence identifications. We then used these three new sequences to more accurately predict the catalytic function of 385 previously uncharacterized or misannotated proteins. We expect that this kind of rapid sequence identification could be efficiently applied on a larger scale to make enzymology's "back catalog" another powerful tool to drive accurate genome annotation.
Practice databases and their uses in clinical research.
Tierney, W M; McDonald, C J
1991-04-01
A few large clinical information databases have been established within larger medical information systems. Although they are smaller than claims databases, these clinical databases offer several advantages: accurate and timely data, rich clinical detail, and continuous parameters (for example, vital signs and laboratory results). However, the nature of the data vary considerably, which affects the kinds of secondary analyses that can be performed. These databases have been used to investigate clinical epidemiology, risk assessment, post-marketing surveillance of drugs, practice variation, resource use, quality assurance, and decision analysis. In addition, practice databases can be used to identify subjects for prospective studies. Further methodologic developments are necessary to deal with the prevalent problems of missing data and various forms of bias if such databases are to grow and contribute valuable clinical information.
Probabilistic liquefaction triggering based on the cone penetration test
Moss, R.E.S.; Seed, R.B.; Kayen, R.E.; Stewart, J.P.; Tokimatsu, K.
2005-01-01
Performance-based earthquake engineering requires a probabilistic treatment of potential failure modes in order to accurately quantify the overall stability of the system. This paper is a summary of the application portions of the probabilistic liquefaction triggering correlations proposed recently proposed by Moss and co-workers. To enable probabilistic treatment of liquefaction triggering, the variables comprising the seismic load and the liquefaction resistance were treated as inherently uncertain. Supporting data from an extensive Cone Penetration Test (CPT)-based liquefaction case history database were used to develop a probabilistic correlation. The methods used to measure the uncertainty of the load and resistance variables, how the interactions of these variables were treated using Bayesian updating, and how reliability analysis was applied to produce curves of equal probability of liquefaction are presented. The normalization for effective overburden stress, the magnitude correlated duration weighting factor, and the non-linear shear mass participation factor used are also discussed.
Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge
2017-01-01
Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures) were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA), Simultaneous Thermal analysis (STA), Laser Flash analysis (LFA), and Fourier Transform Infrared (FTIR) analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D) model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper). The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering. PMID:28772854
Unraveling different chemical fingerprints between a champagne wine and its aerosols.
Liger-Belair, Gérard; Cilindre, Clara; Gougeon, Régis D; Lucio, Marianna; Gebefügi, Istvan; Jeandet, Philippe; Schmitt-Kopplin, Philippe
2009-09-29
As champagne or sparkling wine is poured into a glass, the myriad of ascending bubbles collapse and radiate a multitude of tiny droplets above the free surface into the form of very characteristic and refreshing aerosols. Ultrahigh-resolution MS was used as a nontargeted approach to discriminate hundreds of surface active compounds that are preferentially partitioning in champagne aerosols; thus, unraveling different chemical fingerprints between the champagne bulk and its aerosols. Based on accurate exact mass analysis and database search, tens of these compounds overconcentrating in champagne aerosols were unambiguously discriminated and assigned to compounds showing organoleptic interest or being aromas precursors. By drawing a parallel between the fizz of the ocean and the fizz in Champagne wines, our results closely link bursting bubbles and flavor release; thus, supporting the idea that rising and collapsing bubbles act as a continuous paternoster lift for aromas in every glass of champagne.
Bringing modeling to the masses: A web based system to predict potential species distributions
Graham, Jim; Newman, Greg; Kumar, Sunil; Jarnevich, Catherine S.; Young, Nick; Crall, Alycia W.; Stohlgren, Thomas J.; Evangelista, Paul
2010-01-01
Predicting current and potential species distributions and abundance is critical for managing invasive species, preserving threatened and endangered species, and conserving native species and habitats. Accurate predictive models are needed at local, regional, and national scales to guide field surveys, improve monitoring, and set priorities for conservation and restoration. Modeling capabilities, however, are often limited by access to software and environmental data required for predictions. To address these needs, we built a comprehensive web-based system that: (1) maintains a large database of field data; (2) provides access to field data and a wealth of environmental data; (3) accesses values in rasters representing environmental characteristics; (4) runs statistical spatial models; and (5) creates maps that predict the potential species distribution. The system is available online at www.niiss.org, and provides web-based tools for stakeholders to create potential species distribution models and maps under current and future climate scenarios.
Unraveling different chemical fingerprints between a champagne wine and its aerosols
Liger-Belair, Gérard; Cilindre, Clara; Gougeon, Régis D.; Lucio, Marianna; Gebefügi, Istvan; Jeandet, Philippe; Schmitt-Kopplin, Philippe
2009-01-01
As champagne or sparkling wine is poured into a glass, the myriad of ascending bubbles collapse and radiate a multitude of tiny droplets above the free surface into the form of very characteristic and refreshing aerosols. Ultrahigh-resolution MS was used as a nontargeted approach to discriminate hundreds of surface active compounds that are preferentially partitioning in champagne aerosols; thus, unraveling different chemical fingerprints between the champagne bulk and its aerosols. Based on accurate exact mass analysis and database search, tens of these compounds overconcentrating in champagne aerosols were unambiguously discriminated and assigned to compounds showing organoleptic interest or being aromas precursors. By drawing a parallel between the fizz of the ocean and the fizz in Champagne wines, our results closely link bursting bubbles and flavor release; thus, supporting the idea that rising and collapsing bubbles act as a continuous paternoster lift for aromas in every glass of champagne. PMID:19805335
Massire, Christian; Buelow, Daelynn R.; Zhang, Sean X.; Lovari, Robert; Matthews, Heather E.; Toleno, Donna M.; Ranken, Raymond R.; Hall, Thomas A.; Metzgar, David; Sampath, Rangarajan; Blyn, Lawrence B.; Ecker, David J.; Gu, Zhengming; Walsh, Thomas J.
2013-01-01
Invasive fungal infections are a significant cause of morbidity and mortality among immunocompromised patients. Early and accurate identification of these pathogens is central to direct therapy and to improve overall outcome. PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS) was evaluated as a novel means for identification of fungal pathogens. Using a database grounded by 60 ATCC reference strains, a total of 394 clinical fungal isolates (264 molds and 130 yeasts) were analyzed by PCR/ESI-MS; results were compared to phenotypic identification, and discrepant results were sequence confirmed. PCR/ESI-MS identified 81.4% of molds to either the genus or species level, with concordance rates of 89.7% and 87.4%, respectively, to phenotypic identification. Likewise, PCR/ESI-MS was able to identify 98.4% of yeasts to either the genus or species level, agreeing with 100% of phenotypic results at both the genus and species level. PCR/ESI-MS performed best with Aspergillus and Candida isolates, generating species-level identification in 94.4% and 99.2% of isolates, respectively. PCR/ESI-MS is a promising new technology for broad-range detection and identification of medically important fungal pathogens that cause invasive mycoses. PMID:23303501
Lommen, Arjen
2009-04-15
Hyphenated full-scan MS technology creates large amounts of data. A versatile easy to handle automation tool aiding in the data analysis is very important in handling such a data stream. MetAlign softwareas described in this manuscripthandles a broad range of accurate mass and nominal mass GC/MS and LC/MS data. It is capable of automatic format conversions, accurate mass calculations, baseline corrections, peak-picking, saturation and mass-peak artifact filtering, as well as alignment of up to 1000 data sets. A 100 to 1000-fold data reduction is achieved. MetAlign software output is compatible with most multivariate statistics programs.
Titulaer, Mark K; Siccama, Ivar; Dekker, Lennard J; van Rijswijk, Angelique LCT; Heeren, Ron MA; Sillevis Smitt, Peter A; Luider, Theo M
2006-01-01
Background Statistical comparison of peptide profiles in biomarker discovery requires fast, user-friendly software for high throughput data analysis. Important features are flexibility in changing input variables and statistical analysis of peptides that are differentially expressed between patient and control groups. In addition, integration the mass spectrometry data with the results of other experiments, such as microarray analysis, and information from other databases requires a central storage of the profile matrix, where protein id's can be added to peptide masses of interest. Results A new database application is presented, to detect and identify significantly differentially expressed peptides in peptide profiles obtained from body fluids of patient and control groups. The presented modular software is capable of central storage of mass spectra and results in fast analysis. The software architecture consists of 4 pillars, 1) a Graphical User Interface written in Java, 2) a MySQL database, which contains all metadata, such as experiment numbers and sample codes, 3) a FTP (File Transport Protocol) server to store all raw mass spectrometry files and processed data, and 4) the software package R, which is used for modular statistical calculations, such as the Wilcoxon-Mann-Whitney rank sum test. Statistic analysis by the Wilcoxon-Mann-Whitney test in R demonstrates that peptide-profiles of two patient groups 1) breast cancer patients with leptomeningeal metastases and 2) prostate cancer patients in end stage disease can be distinguished from those of control groups. Conclusion The database application is capable to distinguish patient Matrix Assisted Laser Desorption Ionization (MALDI-TOF) peptide profiles from control groups using large size datasets. The modular architecture of the application makes it possible to adapt the application to handle also large sized data from MS/MS- and Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry experiments. It is expected that the higher resolution and mass accuracy of the FT-ICR mass spectrometry prevents the clustering of peaks of different peptides and allows the identification of differentially expressed proteins from the peptide profiles. PMID:16953879
Titulaer, Mark K; Siccama, Ivar; Dekker, Lennard J; van Rijswijk, Angelique L C T; Heeren, Ron M A; Sillevis Smitt, Peter A; Luider, Theo M
2006-09-05
Statistical comparison of peptide profiles in biomarker discovery requires fast, user-friendly software for high throughput data analysis. Important features are flexibility in changing input variables and statistical analysis of peptides that are differentially expressed between patient and control groups. In addition, integration the mass spectrometry data with the results of other experiments, such as microarray analysis, and information from other databases requires a central storage of the profile matrix, where protein id's can be added to peptide masses of interest. A new database application is presented, to detect and identify significantly differentially expressed peptides in peptide profiles obtained from body fluids of patient and control groups. The presented modular software is capable of central storage of mass spectra and results in fast analysis. The software architecture consists of 4 pillars, 1) a Graphical User Interface written in Java, 2) a MySQL database, which contains all metadata, such as experiment numbers and sample codes, 3) a FTP (File Transport Protocol) server to store all raw mass spectrometry files and processed data, and 4) the software package R, which is used for modular statistical calculations, such as the Wilcoxon-Mann-Whitney rank sum test. Statistic analysis by the Wilcoxon-Mann-Whitney test in R demonstrates that peptide-profiles of two patient groups 1) breast cancer patients with leptomeningeal metastases and 2) prostate cancer patients in end stage disease can be distinguished from those of control groups. The database application is capable to distinguish patient Matrix Assisted Laser Desorption Ionization (MALDI-TOF) peptide profiles from control groups using large size datasets. The modular architecture of the application makes it possible to adapt the application to handle also large sized data from MS/MS- and Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry experiments. It is expected that the higher resolution and mass accuracy of the FT-ICR mass spectrometry prevents the clustering of peaks of different peptides and allows the identification of differentially expressed proteins from the peptide profiles.
Härtig, Claus
2008-01-04
A multidimensional approach for the identification of fatty acid methyl esters (FAME) based on GC/MS analysis is described. Mass spectra and retention data of more than 130 FAME from various sources (chain lengths in the range from 4 to 24 carbon atoms) were collected in a database. Hints for the interpretation of FAME mass spectra are given and relevant diagnostic marker ions are deduced indicating specific groups of fatty acids. To verify the identity of single species and to ensure an optimized chromatographic resolution, the database was compiled with retention data libraries acquired on columns of different polarity (HP-5, DB-23, and HP-88). For a combined use of mass spectra and retention data standardized methods of measurement for each of these columns are required. Such master methods were developed and always applied under the conditions of retention time locking (RTL) which allowed an excellent reproducibility and comparability of absolute retention times. Moreover, as a relative retention index system, equivalent chain lengths (ECL) of FAME were determined by linear interpolation. To compare and to predict ECL values by means of structural features, fractional chain lengths (FCL) were calculated and fitted as well. As shown in an example, the use of retention data and mass spectral information together in a database search leads to an improved and reliable identification of FAME (including positional and geometrical isomers) without further derivatizations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.
Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometrymore » and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.« less
da Cunha, Keith C; Riat, Arnaud; Normand, Anne-Cecile; Bosshard, Philipp P; de Almeida, Margarete T G; Piarroux, Renaud; Schrenzel, Jacques; Fontao, Lionel
2018-05-15
Dermatophytes cause human infections limited to keratinized tissues. We showed that the direct transfer method allows reliable identification of non-dermatophytes mould and yeast by MALDI-TOF/MS. We aimed at assessing whether the direct transfer method can be used for dermatophytes and whether an own mass spectra library would be superior to the Bruker library. We used the Bruker Biotyper to build a dermatophyte mass spectra library and assessed its performance by 1/ testing a panel of mass spectrum produced with strains genotypically identified and, 2/ comparing MALDI-TOF/MS identification to morphology-based methods. Identification of dermatophytes using the Bruker library is poor. Our library provided 97% concordance between ITS sequencing and MALDI-TOF/MS analysis with a panel of 1104 spectra corresponding to 276 strains. Direct transfer method using unpolished target plates allowed proper identification of 85% of dermatophytes clinical isolates most of which were common dermatophytes. A homemade dermatophyte MSP library is a prerequisite for accurate identification of species absent in the Bruker library but it also improves identification of species already listed in the database. The direct deposit method can be used to identify the most commonly found dermatophytes such as T. rubrum and T. interdigitale/mentagrophytes by MALDI-TOF/MS. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Quifer-Rada, Paola; Choy, Ying Yng; Calvert, Christopher C; Waterhouse, Andrew L; Lamuela-Raventos, Rosa M
2016-10-01
This work aims to evaluate changes in the fecal metabolomic profile due to grape seed extract (GSE) intake by untargeted and targeted analysis using high resolution mass spectrometry in conjunction with multivariate statistics. An intervention study with six crossbred female pigs was performed. The pigs followed a standard diet for 3 days, then they were fed with a supplemented diet containing 1% (w/w) of MegaNatural® Gold grape seed extract for 6 days. Fresh pig fecal samples were collected daily. A combination of untargeted high resolution mass spectrometry, multivariate analysis (PLS-DA), data-dependent MS/MS scan, and accurate mass database matching was used to measure the effect of the treatment on fecal composition. The resultant PLS-DA models showed a good discrimination among classes with great robustness and predictability. A total of 14 metabolites related to the GSE consumption were identified including biliary acid, dicarboxylic fatty acid, cholesterol metabolites, purine metabolites, and eicosanoid metabolites among others. Moreover, targeted metabolomics using GC-MS showed that cholesterol and its metabolites fecal excretion was increased due to the proanthocyanidins from grape seed extract. The results show that oligomeric procyanidins from GSE modifies bile acid and steroid excretion, which could exert a hypocholesterolemic effect. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
pyQms enables universal and accurate quantification of mass spectrometry data.
Leufken, Johannes; Niehues, Anna; Sarin, L Peter; Wessel, Florian; Hippler, Michael; Leidel, Sebastian A; Fufezan, Christian
2017-10-01
Quantitative mass spectrometry (MS) is a key technique in many research areas (1), including proteomics, metabolomics, glycomics, and lipidomics. Because all of the corresponding molecules can be described by chemical formulas, universal quantification tools are highly desirable. Here, we present pyQms, an open-source software for accurate quantification of all types of molecules measurable by MS. pyQms uses isotope pattern matching that offers an accurate quality assessment of all quantifications and the ability to directly incorporate mass spectrometer accuracy. pyQms is, due to its universal design, applicable to every research field, labeling strategy, and acquisition technique. This opens ultimate flexibility for researchers to design experiments employing innovative and hitherto unexplored labeling strategies. Importantly, pyQms performs very well to accurately quantify partially labeled proteomes in large scale and high throughput, the most challenging task for a quantification algorithm. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.
USDA-ARS?s Scientific Manuscript database
An optimized single run evaluation that would accurately determine the elemental composition of as many compounds present in an extract would greatly aid in the evaluation of plant tissues. For phytochemicals, we have used accurate mass analysis to quickly characterize the potential chemical formula...
NASA Astrophysics Data System (ADS)
Prata, F.; Stebel, K.
2013-12-01
Over the last few years there has been a recognition of the utility of satellite measurements to identify and track volcanic emissions that present a natural hazard to human populations. Mitigation of the volcanic hazard to life and the environment requires understanding of the properties of volcanic emissions, identifying the hazard in near real-time and being able to provide timely and accurate forecasts to affected areas. Amongst the many ways to measure volcanic emissions, satellite remote sensing is capable of providing global quantitative retrievals of important microphysical parameters such as ash mass loading, ash particle effective radius, infrared optical depth, SO2 partial and total column abundance, plume altitude, aerosol optical depth and aerosol absorbing index. The eruption of Eyjafjallajokull in April-May, 2010 led to increased research and measurement programs to better characterize properties of volcanic ash and the need to establish a data-base in which to store and access these data was confirmed. The European Space Agency (ESA) has recognized the importance of having a quality controlled data-base of satellite retrievals and has funded an activity (VAST) to develop novel remote sensing retrieval schemes and a data-base, initially focused on several recent hazardous volcanic eruptions. As a first step, satellite retrievals for the eruptions of Eyjafjallajokull, Grimsvotn, Puyhue-Cordon Caulle, Nabro, Merapi, Okmok, Kasatochi and Sarychev Peak are being considered. Here we describe the data, retrievals and methods being developed for the data-base. Three important applications of the data-base are illustrated related to the ash/aviation problem, to the impact of the Merapi volcanic eruption on the local population, and to estimate SO2 fluxes from active volcanoes-as a means to diagnose future unrest. Dispersion model simulations are also being included in the data-base. In time, data from conventional in situ sampling instruments, airborne and ground-based remote sensing platforms and other meta-data (bulk ash and gas properties, volcanic setting, volcanic eruption chronologies, hazards and impacts etc.) will be added. The data-base has the potential to provide the natural hazards community with the first dynamic atmospheric volcanic hazards map and will be a valuable tool particularly for global transport.
Soetens, Oriane; De Bel, Annelies; Echahidi, Fedoua; Vancutsem, Ellen; Vandoorslaer, Kristof; Piérard, Denis
2012-01-01
The performance of matrix-assisted laser desorption–ionization time of flight mass spectrometry (MALDI-TOF MS) for species identification of Prevotella was evaluated and compared with 16S rRNA gene sequencing. Using a Bruker database, 62.7% of the 102 clinical isolates were identified to the species level and 73.5% to the genus level. Extension of the commercial database improved these figures to, respectively, 83.3% and 89.2%. MALDI-TOF MS identification of Prevotella is reliable but needs a more extensive database. PMID:22301022
Tian, Ji-Xin; Peng, Can; Xu, Lei; Tian, Yuan; Zhang, Zun-Jian
2013-06-01
In this report, the in vitro metabolism of Strychnos alkaloids was investigated using liquid chromatography/high-resolution mass spectrometry for the first time. Strychnine and brucine were selected as model compounds to determine the universal biotransformations of the Strychnos alkaloids in rat liver microsomes. The incubation mixtures were separated by a bidentate-C18 column, and then analyzed by on-line ion trap/time-of-flight mass spectrometry. With the assistance of mass defect filtering technique, full-scan accurate mass datasets were processed for the discovery of the related metabolites. The structural elucidations of these metabolites were achieved by comparing the changes in accurate molecular masses, calculating chemical component using Formula Predictor software and defining sites of biotransformation based upon accurate MS(n) spectral information. As a result, 31 metabolites were identified, of which 26 metabolites were reported for the first time. These biotransformations included hydroxylation, N-oxidation, epoxidation, methylation, dehydrogenation, de-methoxylation, O-demethylation, as well as hydrolysis reactions. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Morelli, Eugene A.; Cunningham, Kevin; Hill, Melissa A.
2013-01-01
Flight test and modeling techniques were developed for efficiently identifying global aerodynamic models that can be used to accurately simulate stall, upset, and recovery on large transport airplanes. The techniques were developed and validated in a high-fidelity fixed-base flight simulator using a wind-tunnel aerodynamic database, realistic sensor characteristics, and a realistic flight deck representative of a large transport aircraft. Results demonstrated that aerodynamic models for stall, upset, and recovery can be identified rapidly and accurately using relatively simple piloted flight test maneuvers. Stall maneuver predictions and comparisons of identified aerodynamic models with data from the underlying simulation aerodynamic database were used to validate the techniques.
Bogdán, István A.; Rivers, Jenny; Beynon, Robert J.; Coca, Daniel
2008-01-01
Motivation: Peptide mass fingerprinting (PMF) is a method for protein identification in which a protein is fragmented by a defined cleavage protocol (usually proteolysis with trypsin), and the masses of these products constitute a ‘fingerprint’ that can be searched against theoretical fingerprints of all known proteins. In the first stage of PMF, the raw mass spectrometric data are processed to generate a peptide mass list. In the second stage this protein fingerprint is used to search a database of known proteins for the best protein match. Although current software solutions can typically deliver a match in a relatively short time, a system that can find a match in real time could change the way in which PMF is deployed and presented. In a paper published earlier we presented a hardware design of a raw mass spectra processor that, when implemented in Field Programmable Gate Array (FPGA) hardware, achieves almost 170-fold speed gain relative to a conventional software implementation running on a dual processor server. In this article we present a complementary hardware realization of a parallel database search engine that, when running on a Xilinx Virtex 2 FPGA at 100 MHz, delivers 1800-fold speed-up compared with an equivalent C software routine, running on a 3.06 GHz Xeon workstation. The inherent scalability of the design means that processing speed can be multiplied by deploying the design on multiple FPGAs. The database search processor and the mass spectra processor, running on a reconfigurable computing platform, provide a complete real-time PMF protein identification solution. Contact: d.coca@sheffield.ac.uk PMID:18453553
Structure for Storing Properties of Particles (PoP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, N. R.; Mattoon, C. M.; Beck, B. R.
2014-06-01
Some evaluated nuclear databases are critical for applications such as nuclear energy, nuclear medicine, homeland security, and stockpile stewardship. Particle masses, nuclear excitation levels, and other “Properties of Particles” are essential for making evaluated nuclear databases. Currently, these properties are obtained from various databases that are stored in outdated formats. Moreover, the “Properties of Particles” (PoP) structure is being designed that will allow storing all information for one or more particles in a single place, so that each evaluation, simulation, model calculation, etc. can link to the same data. Information provided in PoP will include properties of nuclei, gammas andmore » electrons (along with other particles such as pions, as evaluations extend to higher energies). Presently, PoP includes masses from the Atomic Mass Evaluation version 2003 (AME2003), and level schemes and gamma decays from the Reference Input Parameter Library (RIPL-3). The data are stored in a hierarchical structure. An example of how PoP stores nuclear masses and energy levels will be presented here.« less
Structure for Storing Properties of Particles (PoP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, N.R., E-mail: infinidhi@llnl.gov; Mattoon, C.M.; Beck, B.R.
2014-06-15
Evaluated nuclear databases are critical for applications such as nuclear energy, nuclear medicine, homeland security, and stockpile stewardship. Particle masses, nuclear excitation levels, and other “Properties of Particles” are essential for making evaluated nuclear databases. Currently, these properties are obtained from various databases that are stored in outdated formats. A “Properties of Particles” (PoP) structure is being designed that will allow storing all information for one or more particles in a single place, so that each evaluation, simulation, model calculation, etc. can link to the same data. Information provided in PoP will include properties of nuclei, gammas and electrons (alongmore » with other particles such as pions, as evaluations extend to higher energies). Presently, PoP includes masses from the Atomic Mass Evaluation version 2003 (AME2003), and level schemes and gamma decays from the Reference Input Parameter Library (RIPL-3). The data are stored in a hierarchical structure. An example of how PoP stores nuclear masses and energy levels will be presented here.« less
Environmental Chemistry Compound Identification Using High ...
There is a growing need for rapid chemical screening and prioritization to inform regulatory decision-making on thousands of chemicals in the environment. We have previously used high-resolution mass spectrometry to examine household vacuum dust samples using liquid chromatography time-of-flight mass spectrometry (LC-TOF/MS). Using a combination of exact mass, isotope distribution, and isotope spacing, molecular features were matched with a list of chemical formulas from the EPA’s Distributed Structure-Searchable Toxicity (DSSTox) database. This has further developed our understanding of how openly available chemical databases, together with the appropriate searches, could be used for the purpose of compound identification. We report here on the utility of the EPA’s iCSS Chemistry Dashboard for the purpose of compound identification using searches against a database of over 720,000 chemicals. We also examine the benefits of QSAR prediction for the purpose of retention time prediction to allow for alignment of both chromatographic and mass spectral properties. This abstract does not reflect U.S. EPA policy presentation at the Eastern Analytical Symposium.
Nonparametric Bayesian Modeling for Automated Database Schema Matching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferragut, Erik M; Laska, Jason A
2015-01-01
The problem of merging databases arises in many government and commercial applications. Schema matching, a common first step, identifies equivalent fields between databases. We introduce a schema matching framework that builds nonparametric Bayesian models for each field and compares them by computing the probability that a single model could have generated both fields. Our experiments show that our method is more accurate and faster than the existing instance-based matching algorithms in part because of the use of nonparametric Bayesian models.
Application of furniture images selection based on neural network
NASA Astrophysics Data System (ADS)
Wang, Yong; Gao, Wenwen; Wang, Ying
2018-05-01
In the construction of 2 million furniture image databases, aiming at the problem of low quality of database, a combination of CNN and Metric learning algorithm is proposed, which makes it possible to quickly and accurately remove duplicate and irrelevant samples in the furniture image database. Solve problems that images screening method is complex, the accuracy is not high, time-consuming is long. Deep learning algorithm achieve excellent image matching ability in actual furniture retrieval applications after improving data quality.
THE ART OF DATA MINING THE MINEFIELDS OF TOXICITY ...
Toxicity databases have a special role in predictive toxicology, providing ready access to historical information throughout the workflow of discovery, development, and product safety processes in drug development as well as in review by regulatory agencies. To provide accurate information within a hypothesesbuilding environment, the content of the databases needs to be rigorously modeled using standards and controlled vocabulary. The utilitarian purposes of databases widely vary, ranging from a source for (Q)SAR datasets for modelers to a basis for
Algorithm for detection the QRS complexes based on support vector machine
NASA Astrophysics Data System (ADS)
Van, G. V.; Podmasteryev, K. V.
2017-11-01
The efficiency of computer ECG analysis depends on the accurate detection of QRS-complexes. This paper presents an algorithm for QRS complex detection based of support vector machine (SVM). The proposed algorithm is evaluated on annotated standard databases such as MIT-BIH Arrhythmia database. The QRS detector obtained a sensitivity Se = 98.32% and specificity Sp = 95.46% for MIT-BIH Arrhythmia database. This algorithm can be used as the basis for the software to diagnose electrical activity of the heart.
Sitterlé, E; Giraud, S; Leto, J; Bouchara, J P; Rougeron, A; Morio, F; Dauphin, B; Angebault, C; Quesne, G; Beretti, J L; Hassouni, N; Nassif, X; Bougnoux, M E
2014-09-01
An increasing number of infections due to Pseudallescheria/Scedosporium species has been reported during the past decades, both in immunocompromised and immunocompetent patients. Additionally, these fungi are now recognized worldwide as common agents of fungal colonization of the airways in cystic fibrosis patients, which represents a risk factor for disseminated infections after lung transplantation. Currently six species are described within the Pseudallescheria/Scedosporium genus, including Scedosporium prolificans and species of the Pseudallescheria/Scedosporium apiospermum complex (i.e. S. apiospermum sensu stricto, Pseudallescheria boydii, Scedosporium aurantiacum, Pseudallescheria minutispora and Scedosporium dehoogii). Precise identification of clinical isolates at the species level is required because these species differ in their antifungal drug susceptibility patterns. Matrix-assisted laser desorption ionization (MALDI)-time of flight (TOF)/mass spectrometry (MS) is a powerful tool to rapidly identify moulds at the species level. We investigated the potential of this technology to discriminate Pseudallescheria/Scedosporium species. Forty-seven reference strains were used to build a reference database library. Profiles from 3-, 5- and 7-day-old cultures of each reference strain were analysed to identify species-specific discriminating profiles. The database was tested for accuracy using a set of 64 clinical or environmental isolates previously identified by multilocus sequencing. All isolates were unequivocally identified at the species level by MALDI-TOF/MS. Our results, obtained using a simple protocol, without prior protein extraction or standardization of the culture, demonstrate that MALDI-TOF/MS is a powerful tool for rapid identification of Pseudallescheria/Scedosporium species that cannot be currently identified by morphological examination in the clinical setting. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.
The selective determination of sulfates, sulfonates and phosphates in urine by CE-MS.
Bunz, Svenja-Catharina; Weinmann, Wolfgang; Neusüss, Christian
2010-04-01
Metabolite identification and metabolite profiling are of major importance in the pharmaceutical and clinical context. However, highly polar and ionic substances are rarely included as analytical tools are missing. In this study, we present a new method for the determination of urinary sulfates, sulfonates, phosphates and other anions of strong acids. The method comprises a CE separation using an acidic BGE (pH
NASA Astrophysics Data System (ADS)
Land, Walker H., Jr.; Lewis, Michael; Sadik, Omowunmi; Wong, Lut; Wanekaya, Adam; Gonzalez, Richard J.; Balan, Arun
2004-04-01
This paper extends the classification approaches described in reference [1] in the following way: (1.) developing and evaluating a new method for evolving organophosphate nerve agent Support Vector Machine (SVM) classifiers using Evolutionary Programming, (2.) conducting research experiments using a larger database of organophosphate nerve agents, and (3.) upgrading the architecture to an object-based grid system for evaluating the classification of EP derived SVMs. Due to the increased threats of chemical and biological weapons of mass destruction (WMD) by international terrorist organizations, a significant effort is underway to develop tools that can be used to detect and effectively combat biochemical warfare. This paper reports the integration of multi-array sensors with Support Vector Machines (SVMs) for the detection of organophosphates nerve agents using a grid computing system called Legion. Grid computing is the use of large collections of heterogeneous, distributed resources (including machines, databases, devices, and users) to support large-scale computations and wide-area data access. Finally, preliminary results using EP derived support vector machines designed to operate on distributed systems have provided accurate classification results. In addition, distributed training time architectures are 50 times faster when compared to standard iterative training time methods.
NASA Astrophysics Data System (ADS)
Xu, Xiaojiang; Rioux, Timothy P.; MacLeod, Tynan; Patel, Tejash; Rome, Maxwell N.; Potter, Adam W.
2017-03-01
The purpose of this paper is to develop a database of tissue composition, distribution, volume, surface area, and skin thickness from anatomically correct human models, the virtual family. These models were based on high-resolution magnetic resonance imaging (MRI) of human volunteers, including two adults (male and female) and two children (boy and girl). In the segmented image dataset, each voxel is associated with a label which refers to a tissue type that occupies up that specific cubic millimeter of the body. The tissue volume was calculated from the number of the voxels with the same label. Volumes of 24 organs in body and volumes of 7 tissues in 10 specific body regions were calculated. Surface area was calculated from the collection of voxels that are touching the exterior air. Skin thicknesses were estimated from its volume and surface area. The differences between the calculated and original masses were about 3 % or less for tissues or organs that are important to thermoregulatory modeling, e.g., muscle, skin, and fat. This accurate database of body tissue distributions and geometry is essential for the development of human thermoregulatory models. Data derived from medical imaging provide new effective tools to enhance thermal physiology research and gain deeper insight into the mechanisms of how the human body maintains heat balance.
NASA Technical Reports Server (NTRS)
Walls, Laurie K.; Kirk, Daniel; deLuis, Kavier; Haberbusch, Mark S.
2011-01-01
As space programs increasingly investigate various options for long duration space missions the accurate prediction of propellant behavior over long periods of time in microgravity environment has become increasingly imperative. This has driven the development of a detailed, physics-based understanding of slosh behavior of cryogenic propellants over a range of conditions and environments that are relevant for rocket and space storage applications. Recent advancements in computational fluid dynamics (CFD) models and hardware capabilities have enabled the modeling of complex fluid behavior in microgravity environment. Historically, launch vehicles with moderate duration upper stage coast periods have contained very limited instrumentation to quantify propellant stratification and boil-off in these environments, thus the ability to benchmark these complex computational models is of great consequence. To benchmark enhanced CFD models, recent work focuses on establishing an extensive experimental database of liquid slosh under a wide range of relevant conditions. In addition, a mass gauging system specifically designed to provide high fidelity measurements for both liquid stratification and liquid/ullage position in a micro-gravity environment has been developed. This pUblication will summarize the various experimental programs established to produce this comprehensive database and unique flight measurement techniques.
Ojanperä, Ilkka; Kolmonen, Marjo; Pelander, Anna
2012-05-01
Clinical and forensic toxicology and doping control deal with hundreds or thousands of drugs that may cause poisoning or are abused, are illicit, or are prohibited in sports. Rapid and reliable screening for all these compounds of different chemical and pharmaceutical nature, preferably in a single analytical method, is a substantial effort for analytical toxicologists. Combined chromatography-mass spectrometry techniques with standardised reference libraries have been most commonly used for the purpose. In the last ten years, the focus has shifted from gas chromatography-mass spectrometry to liquid chromatography-mass spectrometry, because of progress in instrument technology and partly because of the polarity and low volatility of many new relevant substances. High-resolution mass spectrometry (HRMS), which enables accurate mass measurement at high resolving power, has recently evolved to the stage that is rapidly causing a shift from unit-resolution, quadrupole-dominated instrumentation. The main HRMS techniques today are time-of-flight mass spectrometry and Orbitrap Fourier-transform mass spectrometry. Both techniques enable a range of different drug-screening strategies that essentially rely on measuring a compound's or a fragment's mass with sufficiently high accuracy that its elemental composition can be determined directly. Accurate mass and isotopic pattern acts as a filter for confirming the identity of a compound or even identification of an unknown. High mass resolution is essential for improving confidence in accurate mass results in the analysis of complex biological samples. This review discusses recent applications of HRMS in analytical toxicology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petyuk, Vladislav A.; Mayampurath, Anoop M.; Monroe, Matthew E.
2009-12-16
Hybrid two-stage mass spectrometers capable of both highly accurate mass measurement and MS/MS fragmentation have become widely available in recent years and have allowed for sig-nificantly better discrimination between true and false MS/MS pep-tide identifications by applying relatively narrow windows for maxi-mum allowable deviations for parent ion mass measurements. To fully gain the advantage of highly accurate parent ion mass meas-urements, it is important to limit systematic mass measurement errors. The DtaRefinery software tool can correct systematic errors in parent ion masses by reading a set of fragmentation spectra, searching for MS/MS peptide identifications, then fitting a model that canmore » estimate systematic errors, and removing them. This results in a new fragmentation spectrum file with updated parent ion masses.« less
Contaminant screening of wastewater with HPLC-IM-qTOF-MS and LC+LC-IM-qTOF-MS using a CCS database.
Stephan, Susanne; Hippler, Joerg; Köhler, Timo; Deeb, Ahmad A; Schmidt, Torsten C; Schmitz, Oliver J
2016-09-01
Non-target analysis has become an important tool in the field of water analysis since a broad variety of pollutants from different sources are released to the water cycle. For identification of compounds in such complex samples, liquid chromatography coupled to high resolution mass spectrometry are often used. The introduction of ion mobility spectrometry provides an additional separation dimension and allows determining collision cross sections (CCS) of the analytes as a further physicochemical constant supporting the identification. A CCS database with more than 500 standard substances including drug-like compounds and pesticides was used for CCS data base search in this work. A non-target analysis of a wastewater sample was initially performed with high performance liquid chromatography (HPLC) coupled to an ion mobility-quadrupole-time of flight mass spectrometer (IM-qTOF-MS). A database search including exact mass (±5 ppm) and CCS (±1 %) delivered 22 different compounds. Furthermore, the same sample was analyzed with a two-dimensional LC method, called LC+LC, developed in our group for the coupling to IM-qTOF-MS. This four dimensional separation platform revealed 53 different compounds, identified over exact mass and CCS, in the examined wastewater sample. It is demonstrated that the CCS database can also help to distinguish between isobaric structures exemplified for cyclophosphamide and ifosfamide. Graphical Abstract Scheme of sample analysis and database screening.
Towards unsupervised polyaromatic hydrocarbons structural assignment from SA-TIMS-FTMS data.
Benigni, Paolo; Marin, Rebecca; Fernandez-Lima, Francisco
2015-10-01
With the advent of high resolution ion mobility analyzers and their coupling to ultrahigh resolution mass spectrometers, there is a need to further develop a theoretical workflow capable of correlating experimental accurate mass and mobility measurements with tridimensional candidate structures. In the present work, a general workflow is described for unsupervised tridimensional structural assignment based on accurate mass measurements, mobility measurements, in silico 2D-3D structure generation, and theoretical mobility calculations. In particular, the potential of this workflow will be shown for the analysis of polyaromatic hydrocarbons from Coal Tar SRM 1597a using selected accumulation - trapped ion mobility spectrometry (SA-TIMS) coupled to Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). The proposed workflow can be adapted to different IMS scenarios, can utilize different collisional cross-section calculators and has the potential to include MS n and IMS n measurements for faster and more accurate tridimensional structural assignment.
Colangelo, Christopher M.; Shifman, Mark; Cheung, Kei-Hoi; Stone, Kathryn L.; Carriero, Nicholas J.; Gulcicek, Erol E.; Lam, TuKiet T.; Wu, Terence; Bjornson, Robert D.; Bruce, Can; Nairn, Angus C.; Rinehart, Jesse; Miller, Perry L.; Williams, Kenneth R.
2015-01-01
We report a significantly-enhanced bioinformatics suite and database for proteomics research called Yale Protein Expression Database (YPED) that is used by investigators at more than 300 institutions worldwide. YPED meets the data management, archival, and analysis needs of a high-throughput mass spectrometry-based proteomics research ranging from a single laboratory, group of laboratories within and beyond an institution, to the entire proteomics community. The current version is a significant improvement over the first version in that it contains new modules for liquid chromatography–tandem mass spectrometry (LC–MS/MS) database search results, label and label-free quantitative proteomic analysis, and several scoring outputs for phosphopeptide site localization. In addition, we have added both peptide and protein comparative analysis tools to enable pairwise analysis of distinct peptides/proteins in each sample and of overlapping peptides/proteins between all samples in multiple datasets. We have also implemented a targeted proteomics module for automated multiple reaction monitoring (MRM)/selective reaction monitoring (SRM) assay development. We have linked YPED’s database search results and both label-based and label-free fold-change analysis to the Skyline Panorama repository for online spectra visualization. In addition, we have built enhanced functionality to curate peptide identifications into an MS/MS peptide spectral library for all of our protein database search identification results. PMID:25712262
Colangelo, Christopher M; Shifman, Mark; Cheung, Kei-Hoi; Stone, Kathryn L; Carriero, Nicholas J; Gulcicek, Erol E; Lam, TuKiet T; Wu, Terence; Bjornson, Robert D; Bruce, Can; Nairn, Angus C; Rinehart, Jesse; Miller, Perry L; Williams, Kenneth R
2015-02-01
We report a significantly-enhanced bioinformatics suite and database for proteomics research called Yale Protein Expression Database (YPED) that is used by investigators at more than 300 institutions worldwide. YPED meets the data management, archival, and analysis needs of a high-throughput mass spectrometry-based proteomics research ranging from a single laboratory, group of laboratories within and beyond an institution, to the entire proteomics community. The current version is a significant improvement over the first version in that it contains new modules for liquid chromatography-tandem mass spectrometry (LC-MS/MS) database search results, label and label-free quantitative proteomic analysis, and several scoring outputs for phosphopeptide site localization. In addition, we have added both peptide and protein comparative analysis tools to enable pairwise analysis of distinct peptides/proteins in each sample and of overlapping peptides/proteins between all samples in multiple datasets. We have also implemented a targeted proteomics module for automated multiple reaction monitoring (MRM)/selective reaction monitoring (SRM) assay development. We have linked YPED's database search results and both label-based and label-free fold-change analysis to the Skyline Panorama repository for online spectra visualization. In addition, we have built enhanced functionality to curate peptide identifications into an MS/MS peptide spectral library for all of our protein database search identification results. Copyright © 2015 The Authors. Production and hosting by Elsevier Ltd.. All rights reserved.
David W. MacFarlane
2015-01-01
Accurately assessing forest biomass potential is contingent upon having accurate tree biomass models to translate data from forest inventories. Building generality into these models is especially important when they are to be applied over large spatial domains, such as regional, national and international scales. Here, new, generalized whole-tree mass / volume...
Lo, Cheikh I.; Fall, Bécaye; Sambe-Ba, Bissoume; Diawara, Silman; Gueye, Mamadou W.; Mediannikov, Oleg; Sokhna, Cheikh; Faye, Ngor; Diemé, Yaya; Wade, Boubacar; Raoult, Didier; Fenollar, Florence
2015-01-01
Our team in Europe has developed the routine clinical laboratory identification of microorganisms by matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS). To evaluate the utility of MALDI-TOF MS in tropical Africa in collaboration with local teams, we installed an apparatus in the Hôpital Principal de Dakar (Senegal), performed routine identification of isolates, and confirmed or completed their identification in France. In the case of discordance or a lack of identification, molecular biology was performed. Overall, 153/191 (80.1%) and 174/191 (91.1%) isolates yielded an accurate and concordant identification for the species and genus, respectively, with the 2 different MALDI-TOF MSs in Dakar and Marseille. The 10 most common bacteria, representing 94.2% of all bacteria routinely identified in the laboratory in Dakar (Escherichia coli, Klebsiella pneumoniae, Streptococcus agalactiae, Acinetobacter baumannii, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus haemolyticus, Enterobacter cloacae, Enterococcus faecalis, and Staphylococcus epidermidis) were accurately identified with the MALDI-TOF MS in Dakar. The most frequent misidentification in Dakar was at the species level for Achromobacter xylosoxidans, which was inaccurately identified as Achromobacter denitrificans, and the bacteria absent from the database, such as Exiguobacterium aurientacum or Kytococcus schroeteri, could not be identified. A few difficulties were observed with MALDI-TOF MS for Bacillus sp. or oral streptococci. 16S rRNA sequencing identified a novel bacterium, “Necropsobacter massiliensis.” The robust identification of microorganisms by MALDI-TOF MS in Dakar and Marseille demonstrates that MALDI-TOF MS can be used as a first-line tool in clinical microbiology laboratories in tropical countries. PMID:26716681
Using regression methods to estimate stream phosphorus loads at the Illinois River, Arkansas
Haggard, B.E.; Soerens, T.S.; Green, W.R.; Richards, R.P.
2003-01-01
The development of total maximum daily loads (TMDLs) requires evaluating existing constituent loads in streams. Accurate estimates of constituent loads are needed to calibrate watershed and reservoir models for TMDL development. The best approach to estimate constituent loads is high frequency sampling, particularly during storm events, and mass integration of constituents passing a point in a stream. Most often, resources are limited and discrete water quality samples are collected on fixed intervals and sometimes supplemented with directed sampling during storm events. When resources are limited, mass integration is not an accurate means to determine constituent loads and other load estimation techniques such as regression models are used. The objective of this work was to determine a minimum number of water-quality samples needed to provide constituent concentration data adequate to estimate constituent loads at a large stream. Twenty sets of water quality samples with and without supplemental storm samples were randomly selected at various fixed intervals from a database at the Illinois River, northwest Arkansas. The random sets were used to estimate total phosphorus (TP) loads using regression models. The regression-based annual TP loads were compared to the integrated annual TP load estimated using all the data. At a minimum, monthly sampling plus supplemental storm samples (six samples per year) was needed to produce a root mean square error of less than 15%. Water quality samples should be collected at least semi-monthly (every 15 days) in studies less than two years if seasonal time factors are to be used in the regression models. Annual TP loads estimated from independently collected discrete water quality samples further demonstrated the utility of using regression models to estimate annual TP loads in this stream system.
Frequency-Magnitude relationships for Underwater Landslides of the Mediterranean Sea
NASA Astrophysics Data System (ADS)
Urgeles, R.; Gràcia, E.; Lo Iacono, C.; Sànchez-Serra, C.; Løvholt, F.
2017-12-01
An updated version of the submarine landslide database of the Mediterranean Sea contains 955 MTDs and 2608 failure scars showing that submarine landslides are ubiquitous features along Mediterranean continental margins. Their distribution reveals that major deltaic wedges display the larger submarine landslides, while seismically active margins are characterized by relatively small failures. In all regions, landslide size distributions display power law scaling for landslides > 1 km3. We find consistent differences on the exponent of the power law depending on the geodynamic setting. Active margins present steep slopes of the frequency-magnitude relationship whereas passive margins tend to display gentler slopes. This pattern likely responds to the common view that tectonically active margins have numerous but small failures, while passive margins have larger but fewer failures. Available age information suggests that failures exceeding 1000 km3 are infrequent and may recur every 40 kyr. Smaller failures that can still cause significant damage might be relatively frequent, with failures > 1 km3 likely recurring every 40 years. The database highlights that our knowledge of submarine landslide activity with time is limited to a few tens of thousand years. Available data suggest that submarine landslides may preferentially occur during lowstand periods, but no firm conclusion can be made on this respect, as only 149 landslides (out of 955 included in the database) have relatively accurate age determinations. The timing and regional changes in the frequency-magnitude distribution suggest that sedimentation patterns and pore pressure development have had a major role in triggering slope failures and control the sediment flux from mass wasting to the deep basin.
Accessing the SEED genome databases via Web services API: tools for programmers.
Disz, Terry; Akhter, Sajia; Cuevas, Daniel; Olson, Robert; Overbeek, Ross; Vonstein, Veronika; Stevens, Rick; Edwards, Robert A
2010-06-14
The SEED integrates many publicly available genome sequences into a single resource. The database contains accurate and up-to-date annotations based on the subsystems concept that leverages clustering between genomes and other clues to accurately and efficiently annotate microbial genomes. The backend is used as the foundation for many genome annotation tools, such as the Rapid Annotation using Subsystems Technology (RAST) server for whole genome annotation, the metagenomics RAST server for random community genome annotations, and the annotation clearinghouse for exchanging annotations from different resources. In addition to a web user interface, the SEED also provides Web services based API for programmatic access to the data in the SEED, allowing the development of third-party tools and mash-ups. The currently exposed Web services encompass over forty different methods for accessing data related to microbial genome annotations. The Web services provide comprehensive access to the database back end, allowing any programmer access to the most consistent and accurate genome annotations available. The Web services are deployed using a platform independent service-oriented approach that allows the user to choose the most suitable programming platform for their application. Example code demonstrate that Web services can be used to access the SEED using common bioinformatics programming languages such as Perl, Python, and Java. We present a novel approach to access the SEED database. Using Web services, a robust API for access to genomics data is provided, without requiring large volume downloads all at once. The API ensures timely access to the most current datasets available, including the new genomes as soon as they come online.
Hand-held computer operating system program for collection of resident experience data.
Malan, T K; Haffner, W H; Armstrong, A Y; Satin, A J
2000-11-01
To describe a system for recording resident experience involving hand-held computers with the Palm Operating System (3 Com, Inc., Santa Clara, CA). Hand-held personal computers (PCs) are popular, easy to use, inexpensive, portable, and can share data among other operating systems. Residents in our program carry individual hand-held database computers to record Residency Review Committee (RRC) reportable patient encounters. Each resident's data is transferred to a single central relational database compatible with Microsoft Access (Microsoft Corporation, Redmond, WA). Patient data entry and subsequent transfer to a central database is accomplished with commercially available software that requires minimal computer expertise to implement and maintain. The central database can then be used for statistical analysis or to create required RRC resident experience reports. As a result, the data collection and transfer process takes less time for residents and program director alike, than paper-based or central computer-based systems. The system of collecting resident encounter data using hand-held computers with the Palm Operating System is easy to use, relatively inexpensive, accurate, and secure. The user-friendly system provides prompt, complete, and accurate data, enhancing the education of residents while facilitating the job of the program director.
Turnipseed, Sherri B; Clark, Susan B; Storey, Joseph M; Carr, Justin R
2012-05-09
A liquid chromatography quadrupole time-of-flight (Q-TOF) mass spectrometry method was developed to analyze veterinary drug residues in frog legs and other aquacultured species. Samples were extracted using a procedure based on a method developed for the analysis of fluoroquinolones (FQs) in fish. Briefly, the tissue was extracted with dilute acetic acid and acetonitrile with added sodium chloride. After centrifugation, the extracts were evaporated and reconstituted in mobile phase. A molecular weight cutoff filter was used to clean up the final extract. A set of target compounds, including trimethoprim, sulfamethoxazole, chloramphenicol, quinolones, and FQs, was used to validate the method. Screening of residues was accomplished by collecting TOF (MS¹) data and comparing the accurate mass and retention times of compounds to a database containing information for veterinary drugs. An evaluation of the MS data in fortified frog legs indicated that the target compounds could be consistently detected at the level of concern. The linearity and recoveries from matrix were evaluated for these analytes to estimate the amount of residue present. MS/MS data were also generated from precursor ions, and the mass accuracy of the product ions for each compound was compared to theoretical values. When the method was used to analyze imported frog legs, many of these residues were found in the samples, often in combination and at relatively high concentrations (>10 ng/g). The data from these samples were also evaluated for nontarget analytes such as residue metabolites and other chemotherapeutics.
Direct hydrocarbon identification using AVO analysis in the Malay Basin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lye, Y.C.; Yaacob, M.R.; Birkett, N.E.
1994-07-01
Esso Production Malaysia Inc. and Petronas Carigali Sdn. Bhd. have been conducting AVO (amplitude versus offset) processing and interpretation since April 1991 in an attempt to identify hydrocarbon fluids predrill. The major part of this effort was in the PM-5, PM-8, and PM-9 contract areas where an extensive exploration program is underway. To date, more than 1000 km of seismic data have been analyzed using the AVO technique, and the results were used to support the drilling of more than 50 exploration and delineation wells. Gather modeling of well data was used to calibrate and predict the presence of hydrocarbonmore » in proposed well locations. In order to generate accurate gather models, a geophysical properties and AVO database was needed, and great effort was spent in producing an accurate and complete database. This database is continuously being updated so that an experience file can be built to further improve the reliability of the AVO prediction.« less
Matthiesen, Rune; Kirpekar, Finn
2009-01-01
The idea of identifying or characterizing an RNA molecule based on a mass spectrum of specifically generated RNA fragments has been used in various forms for well over a decade. We have developed software—named RRM for ‘RNA mass mapping’—which can search whole prokaryotic genomes or RNA FASTA sequence databases to identify the origin of a given RNA based on a mass spectrum of RNA fragments. As input, the program uses the masses of specific RNase cleavage of the RNA under investigation. RNase T1 digestion is used here as a demonstration of the usability of the method for RNA identification. The concept for identification is that the masses of the digestion products constitute a specific fingerprint, which characterize the given RNA. The search algorithm is based on the same principles as those used in peptide mass fingerprinting, but has here been extended to work for both RNA sequence databases and for genome searches. A simple and powerful probability model for ranking RNA matches is proposed. We demonstrate viability of the entire setup by identifying the DNA template of a series of RNAs of biological and of in vitro transcriptional origin in complete microbial genomes and by identifying authentic 16S ribosomal RNAs in a ‘small ribosomal subunit RNA’ database. Thus, we present a new tool for a rapid identification of unknown RNAs using only a few picomoles of starting material. PMID:19264806
Using PHP/MySQL to Manage Potential Mass Impacts
NASA Technical Reports Server (NTRS)
Hager, Benjamin I.
2010-01-01
This paper presents a new application using commercially available software to manage mass properties for spaceflight vehicles. PHP/MySQL(PHP: Hypertext Preprocessor and My Structured Query Language) are a web scripting language and a database language commonly used in concert with each other. They open up new opportunities to develop cutting edge mass properties tools, and in particular, tools for the management of potential mass impacts (threats and opportunities). The paper begins by providing an overview of the functions and capabilities of PHP/MySQL. The focus of this paper is on how PHP/MySQL are being used to develop an advanced "web accessible" database system for identifying and managing mass impacts on NASA's Ares I Upper Stage program, managed by the Marshall Space Flight Center. To fully describe this application, examples of the data, search functions, and views are provided to promote, not only the function, but the security, ease of use, simplicity, and eye-appeal of this new application. This paper concludes with an overview of the other potential mass properties applications and tools that could be developed using PHP/MySQL. The premise behind this paper is that PHP/MySQL are software tools that are easy to use and readily available for the development of cutting edge mass properties applications. These tools are capable of providing "real-time" searching and status of an active database, automated report generation, and other capabilities to streamline and enhance mass properties management application. By using PHP/MySQL, proven existing methods for managing mass properties can be adapted to present-day information technology to accelerate mass properties data gathering, analysis, and reporting, allowing mass property management to keep pace with today's fast-pace design and development processes.
Thurman, E.M.; Ferrer, I.; Parry, R.
2002-01-01
Degradates of acetochlor and alachlor (ethanesulfonic acids, ESAs) were analyzed in both standards and in a groundwater sample using high-performance liquid chromatography-time-of-flight mass spectrometry with electrospray ionization. The negative pseudomolecular ion of the secondary amide of acetochlor ESA and alachlor ESA gave average masses of 256.0750??0.0049 amu and 270.0786??0.0064 amu respectively. Acetochlor and alachlor ESA gave similar masses of 314.1098??0.0061 amu and 314.1153??0.0048 amu; however, they could not be distinguished by accurate mass because they have the same empirical formula. On the other hand, they may be distinguished using positive-ion electrospray because of different fragmentation spectra, which did not occur using negative-ion electrospray.
Thurman, E.M.; Ferrer, Imma; Parry, R.
2002-01-01
Degradates of acetochlor and alachlor (ethanesulfonic acids, ESAs) were analyzed in both standards and in a groundwater sample using high-performance liquid chromatography-time-of-flight mass spectrometry with electrospray ionization. The negative pseudomolecular ion of the secondary amide of acetochlor ESA and alachlor ESA gave average masses of 256.0750+/-0.0049 amu and 270.0786+/-0.0064 amu respectively. Acetochlor and alachlor ESA gave similar masses of 314.1098+/-0.0061 amu and 314.1153+/-0.0048 amu; however, they could not be distinguished by accurate mass because they have the same empirical formula. On the other hand, they may be distinguished using positive-ion electrospray because of different fragmentation spectra, which did not occur using negative-ion electrospray.
Li, Ming; Josephs, Ralf D; Daireaux, Adeline; Choteau, Tiphaine; Westwood, Steven; Wielgosz, Robert I; Li, Hongmei
2018-06-04
Peptides are an increasingly important group of biomarkers and pharmaceuticals. The accurate purity characterization of peptide calibrators is critical for the development of reference measurement systems for laboratory medicine and quality control of pharmaceuticals. The peptides used for these purposes are increasingly produced through peptide synthesis. Various approaches (for example mass balance, amino acid analysis, qNMR, and nitrogen determination) can be applied to accurately value assign the purity of peptide calibrators. However, all purity assessment approaches require a correction for structurally related peptide impurities in order to avoid biases. Liquid chromatography coupled to high resolution mass spectrometry (LC-hrMS) has become the key technique for the identification and accurate quantification of structurally related peptide impurities in intact peptide calibrator materials. In this study, LC-hrMS-based methods were developed and validated in-house for the identification and quantification of structurally related peptide impurities in a synthetic human C-peptide (hCP) material, which served as a study material for an international comparison looking at the competencies of laboratories to perform peptide purity mass fraction assignments. More than 65 impurities were identified, confirmed, and accurately quantified by using LC-hrMS. The total mass fraction of all structurally related peptide impurities in the hCP study material was estimated to be 83.3 mg/g with an associated expanded uncertainty of 3.0 mg/g (k = 2). The calibration hierarchy concept used for the quantification of individual impurities is described in detail. Graphical abstract ᅟ.
Unsupervised Indoor Localization Based on Smartphone Sensors, iBeacon and Wi-Fi.
Chen, Jing; Zhang, Yi; Xue, Wei
2018-04-28
In this paper, we propose UILoc, an unsupervised indoor localization scheme that uses a combination of smartphone sensors, iBeacons and Wi-Fi fingerprints for reliable and accurate indoor localization with zero labor cost. Firstly, compared with the fingerprint-based method, the UILoc system can build a fingerprint database automatically without any site survey and the database will be applied in the fingerprint localization algorithm. Secondly, since the initial position is vital to the system, UILoc will provide the basic location estimation through the pedestrian dead reckoning (PDR) method. To provide accurate initial localization, this paper proposes an initial localization module, a weighted fusion algorithm combined with a k-nearest neighbors (KNN) algorithm and a least squares algorithm. In UILoc, we have also designed a reliable model to reduce the landmark correction error. Experimental results show that the UILoc can provide accurate positioning, the average localization error is about 1.1 m in the steady state, and the maximum error is 2.77 m.
Simpkins, D.G.; Hubert, W.A.; Martinez Del Rio, C.; Rule, D.C.
2003-01-01
Abstract: We assessed changes in proximate body composition, wet mass, and the occurrence of mortality among sedentary and actively swimming (15 cm/s) juvenile rainbow trout (Oncorhynchus mykiss) (120-142 mm total length) that were held at 4.0, 7.5, or 15.0 ??C and fasted for 140 days. Warmer water temperatures and swimming activity accentuated declines in lipid mass, but they did not similarly affect lean mass and wet mass. Swimming fish conserved lean mass independent of water temperature. Because lean mass exceeded lipid mass, wet mass was not affected substantially by decreases in lipid mass. Consequently, wet mass did not accurately reflect the effects that water temperature and swimming activity had on mortality of fasted rainbow trout. Rather, lipid mass was more accurate in predicting death from starvation. Juvenile rainbow trout survived long periods without food, and fish that died of starvation appeared to have similar body composition. It appears that the ability of fish to endure periods without food depends on the degree to which lipid mass and lean mass can be utilized as energy sources.
Fei, Lin; Zhao, Jing; Leng, Jiahao; Zhang, Shujian
2017-10-12
The ALIPORC full-text database is targeted at a specific full-text database of acupuncture literature in the Republic of China. Starting in 2015, till now, the database has been getting completed, focusing on books relevant with acupuncture, articles and advertising documents, accomplished or published in the Republic of China. The construction of this database aims to achieve the source sharing of acupuncture medical literature in the Republic of China through the retrieval approaches to diversity and accurate content presentation, contributes to the exchange of scholars, reduces the paper damage caused by paging and simplify the retrieval of the rare literature. The writers have made the explanation of the database in light of sources, characteristics and current situation of construction; and have discussed on improving the efficiency and integrity of the database and deepening the development of acupuncture literature in the Republic of China.
A global, open-source database of flood protection standards
NASA Astrophysics Data System (ADS)
Scussolini, Paolo; Aerts, Jeroen; Jongman, Brenden; Bouwer, Laurens; Winsemius, Hessel; de Moel, Hans; Ward, Philip
2016-04-01
Accurate flood risk estimation is pivotal in that it enables risk-informed policies in disaster risk reduction, as emphasized in the recent Sendai framework for Disaster Risk Reduction. To improve our understanding of flood risk, models are now capable to provide actionable risk information on the (sub)global scale. Still the accuracy of their results is greatly limited by the lack of information on standards of protection to flood that are actually in place; and researchers thus take large assumptions on the extent of protection. With our work we propose a first global, open-source database of FLOod PROtection Standards, FLOPROS, covering a range of spatial scales. FLOPROS is structured in three layers of information, and merges them into one consistent database: 1) the Design layer contains empirical information about the standard of protection presently in place; 2) the Policy layer contains intended protection standards from normative documents; 3) the Model layer uses a validated numerical approach to calculate protection standards for areas not covered in the other layers. The FLOPROS database can be used for more accurate risk assessment exercises across scales. As the database should be continually updated to reflect new interventions, we invite researchers and practitioners to contribute information. Further, we look for partners within the risk community to participate in additional strategies to implement the amount and accuracy of information contained in this first version of FLOPROS.
Wong, Diane K.; Lee, Bai-Yu; Horwitz, Marcus A.; Gibson, Bradford W.
1999-01-01
Iron plays a critical role in the pathophysiology of Mycobacterium tuberculosis. To gain a better understanding of iron regulation by this organism, we have used two-dimensional (2-D) gel electrophoresis, mass spectrometry, and database searching to study protein expression in M. tuberculosis under conditions of high and low iron concentration. Proteins in cellular extracts from M. tuberculosis Erdman strain grown under low-iron (1 μM) and high-iron (70 μM) conditions were separated by 2-D polyacrylamide gel electrophoresis, which allowed high-resolution separation of several hundred proteins, as visualized by Coomassie staining. The expression of at least 15 proteins was induced, and the expression of at least 12 proteins was decreased under low-iron conditions. In-gel trypsin digestion was performed on these differentially expressed proteins, and the digestion mixtures were analyzed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry to determine the molecular masses of the resulting tryptic peptides. Partial sequence data on some of the peptides were obtained by using after source decay and/or collision-induced dissociation. The fragmentation data were used to search computerized peptide mass and protein sequence databases for known proteins. Ten iron-regulated proteins were identified, including Fur and aconitase proteins, both of which are known to be regulated by iron in other bacterial systems. Our study shows that, where large protein sequence databases are available from genomic studies, the combined use of 2-D gel electrophoresis, mass spectrometry, and database searching to analyze proteins expressed under defined environmental conditions is a powerful tool for identifying expressed proteins and their physiologic relevance. PMID:9864233
A prototypic small molecule database for bronchoalveolar lavage-based metabolomics
NASA Astrophysics Data System (ADS)
Walmsley, Scott; Cruickshank-Quinn, Charmion; Quinn, Kevin; Zhang, Xing; Petrache, Irina; Bowler, Russell P.; Reisdorph, Richard; Reisdorph, Nichole
2018-04-01
The analysis of bronchoalveolar lavage fluid (BALF) using mass spectrometry-based metabolomics can provide insight into lung diseases, such as asthma. However, the important step of compound identification is hindered by the lack of a small molecule database that is specific for BALF. Here we describe prototypic, small molecule databases derived from human BALF samples (n=117). Human BALF was extracted into lipid and aqueous fractions and analyzed using liquid chromatography mass spectrometry. Following filtering to reduce contaminants and artifacts, the resulting BALF databases (BALF-DBs) contain 11,736 lipid and 658 aqueous compounds. Over 10% of these were found in 100% of samples. Testing the BALF-DBs using nested test sets produced a 99% match rate for lipids and 47% match rate for aqueous molecules. Searching an independent dataset resulted in 45% matching to the lipid BALF-DB compared to<25% when general databases are searched. The BALF-DBs are available for download from MetaboLights. Overall, the BALF-DBs can reduce false positives and improve confidence in compound identification compared to when general databases are used.
Padliya, Neerav D; Garrett, Wesley M; Campbell, Kimberly B; Tabb, David L; Cooper, Bret
2007-11-01
LC-MS/MS has demonstrated potential for detecting plant pathogens. Unlike PCR or ELISA, LC-MS/MS does not require pathogen-specific reagents for the detection of pathogen-specific proteins and peptides. However, the MS/MS approach we and others have explored does require a protein sequence reference database and database-search software to interpret tandem mass spectra. To evaluate the limitations of database composition on pathogen identification, we analyzed proteins from cultured Ustilago maydis, Phytophthora sojae, Fusarium graminearum, and Rhizoctonia solani by LC-MS/MS. When the search database did not contain sequences for a target pathogen, or contained sequences to related pathogens, target pathogen spectra were reliably matched to protein sequences from nontarget organisms, giving an illusion that proteins from nontarget organisms were identified. Our analysis demonstrates that when database-search software is used as part of the identification process, a paradox exists whereby additional sequences needed to detect a wide variety of possible organisms may lead to more cross-species protein matches and misidentification of pathogens.
Mass and Reliability Source (MaRS) Database
NASA Technical Reports Server (NTRS)
Valdenegro, Wladimir
2017-01-01
The Mass and Reliability Source (MaRS) Database consolidates components mass and reliability data for all Oribital Replacement Units (ORU) on the International Space Station (ISS) into a single database. It was created to help engineers develop a parametric model that relates hardware mass and reliability. MaRS supplies relevant failure data at the lowest possible component level while providing support for risk, reliability, and logistics analysis. Random-failure data is usually linked to the ORU assembly. MaRS uses this data to identify and display the lowest possible component failure level. As seen in Figure 1, the failure point is identified to the lowest level: Component 2.1. This is useful for efficient planning of spare supplies, supporting long duration crewed missions, allowing quicker trade studies, and streamlining diagnostic processes. MaRS is composed of information from various databases: MADS (operating hours), VMDB (indentured part lists), and ISS PART (failure data). This information is organized in Microsoft Excel and accessed through a program made in Microsoft Access (Figure 2). The focus of the Fall 2017 internship tour was to identify the components that were the root cause of failure from the given random-failure data, develop a taxonomy for the database, and attach material headings to the component list. Secondary objectives included verifying the integrity of the data in MaRS, eliminating any part discrepancies, and generating documentation for future reference. Due to the nature of the random-failure data, data mining had to be done manually without the assistance of an automated program to ensure positive identification.
Droit, Arnaud; Hunter, Joanna M; Rouleau, Michèle; Ethier, Chantal; Picard-Cloutier, Aude; Bourgais, David; Poirier, Guy G
2007-01-01
Background In the "post-genome" era, mass spectrometry (MS) has become an important method for the analysis of proteins and the rapid advancement of this technique, in combination with other proteomics methods, results in an increasing amount of proteome data. This data must be archived and analysed using specialized bioinformatics tools. Description We herein describe "PARPs database," a data analysis and management pipeline for liquid chromatography tandem mass spectrometry (LC-MS/MS) proteomics. PARPs database is a web-based tool whose features include experiment annotation, protein database searching, protein sequence management, as well as data-mining of the peptides and proteins identified. Conclusion Using this pipeline, we have successfully identified several interactions of biological significance between PARP-1 and other proteins, namely RFC-1, 2, 3, 4 and 5. PMID:18093328
NASA Astrophysics Data System (ADS)
Larson, Evan A.; Hutchinson, Carolyn P.; Lee, Young Jin
2018-06-01
Dopant-assisted atmospheric pressure chemical ionization (dAPCI) is a soft ionization method rarely used for gas chromatography-mass spectrometry (GC-MS). The current study combines GC-dAPCI with tandem mass spectrometry (MS/MS) for analysis of a complex mixture such as lignin pyrolysis analysis. To identify the structures of volatile lignin pyrolysis products, collision-induced dissociation (CID) MS/MS using a quadrupole time-of-flight mass spectrometer (QTOFMS) and pseudo MS/MS through in-source collision-induced dissociation (ISCID) using a single stage TOFMS are utilized. To overcome the lack of MS/MS database, Compound Structure Identification (CSI):FingerID is used to interpret CID spectra and predict best matched structures from PubChem library. With this approach, a total of 59 compounds were positively identified in comparison to only 22 in NIST database search of GC-EI-MS dataset. This study demonstrates the effectiveness of GC-dAPCI-MS/MS to overcome the limitations of traditional GC-EI-MS analysis when EI-MS database is not sufficient. [Figure not available: see fulltext.
RADS Version 4: An Efficient Way to Analyse the Multi-Mission Altimeter Database
NASA Astrophysics Data System (ADS)
Scharroo, Remko; Leuliette, Eric; Naeije, Marc; Martin-Puig, Cristina; Pires, Nelson
2016-08-01
The Radar Altimeter Database System (RADS) has grown to become a mature altimeter database. Over the last 18 years it is continuously being developed, first at Delft University of Technology, now also at the National Oceanic and Atmospheric Administration (NOAA) and the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT).RADS now serves as a fundamental Climate Data Record for sea level. Because of the multiple users involved in vetting the data and the regular updates to the database, RADS is one of the most accurate and complete databases of satellite altimeter data around.RADS version 4 is a major change from the previous version. While the database is compatible with both software versions, the new software provides new tools, allows easier expansion, and has a better and more standardised interface.
Imaging with Mass Spectrometry of Bacteria on the Exoskeleton of Fungus-Growing Ants.
Gemperline, Erin; Horn, Heidi A; DeLaney, Kellen; Currie, Cameron R; Li, Lingjun
2017-08-18
Mass spectrometry imaging is a powerful analytical technique for detecting and determining spatial distributions of molecules within a sample. Typically, mass spectrometry imaging is limited to the analysis of thin tissue sections taken from the middle of a sample. In this work, we present a mass spectrometry imaging method for the detection of compounds produced by bacteria on the outside surface of ant exoskeletons in response to pathogen exposure. Fungus-growing ants have a specialized mutualism with Pseudonocardia, a bacterium that lives on the ants' exoskeletons and helps protect their fungal garden food source from harmful pathogens. The developed method allows for visualization of bacterial-derived compounds on the ant exoskeleton. This method demonstrates the capability to detect compounds that are specifically localized to the bacterial patch on ant exoskeletons, shows good reproducibility across individual ants, and achieves accurate mass measurements within 5 ppm error when using a high-resolution, accurate-mass mass spectrometer.
A Circular Dichroism Reference Database for Membrane Proteins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace,B.; Wien, F.; Stone, T.
2006-01-01
Membrane proteins are a major product of most genomes and the target of a large number of current pharmaceuticals, yet little information exists on their structures because of the difficulty of crystallising them; hence for the most part they have been excluded from structural genomics programme targets. Furthermore, even methods such as circular dichroism (CD) spectroscopy which seek to define secondary structure have not been fully exploited because of technical limitations to their interpretation for membrane embedded proteins. Empirical analyses of circular dichroism (CD) spectra are valuable for providing information on secondary structures of proteins. However, the accuracy of themore » results depends on the appropriateness of the reference databases used in the analyses. Membrane proteins have different spectral characteristics than do soluble proteins as a result of the low dielectric constants of membrane bilayers relative to those of aqueous solutions (Chen & Wallace (1997) Biophys. Chem. 65:65-74). To date, no CD reference database exists exclusively for the analysis of membrane proteins, and hence empirical analyses based on current reference databases derived from soluble proteins are not adequate for accurate analyses of membrane protein secondary structures (Wallace et al (2003) Prot. Sci. 12:875-884). We have therefore created a new reference database of CD spectra of integral membrane proteins whose crystal structures have been determined. To date it contains more than 20 proteins, and spans the range of secondary structures from mostly helical to mostly sheet proteins. This reference database should enable more accurate secondary structure determinations of membrane embedded proteins and will become one of the reference database options in the CD calculation server DICHROWEB (Whitmore & Wallace (2004) NAR 32:W668-673).« less
DETERMINING ION COMPOSITIONS USING AN ACCURATE MASS, TRIPLE QUADRUPOLE MASS SPECTROMETER
For the past decade, we have used double focusing mass spectrometers to determine
compositions of ions observed in mass spectra produced from compounds introduced by GC
based on measured exact masses of the ions and their +1 and +2 isotopic profiles arising from atoms of ...
Accurate mass measurements and their appropriate use for reliable analyte identification.
Godfrey, A Ruth; Brenton, A Gareth
2012-09-01
Accurate mass instrumentation is becoming increasingly available to non-expert users. This data can be mis-used, particularly for analyte identification. Current best practice in assigning potential elemental formula for reliable analyte identification has been described with modern informatic approaches to analyte elucidation, including chemometric characterisation, data processing and searching using facilities such as the Chemical Abstracts Service (CAS) Registry and Chemspider.
The white dwarf mass-radius relation with Gaia, Hubble and FUSE
NASA Astrophysics Data System (ADS)
Joyce, Simon R. G.; Barstow, Martin A.; Casewell, Sarah L.; Holberg, Jay B.; Bond, Howard E.
2018-04-01
White dwarfs are becoming useful tools for many areas of astronomy. They can be used as accurate chronometers over Gyr timescales. They are also clues to the history of star formation in our galaxy. Many of these studies require accurate estimates of the mass of the white dwarf. The theoretical mass-radius relation is often invoked to provide these mass estimates. While the theoretical mass-radius relation is well developed, observational tests of this relation show a much larger scatter in the results than expected. High precision observational tests to confirm this relation are required. Gaia is providing distance measurements which will remove one of the main source of uncertainty affecting most previous observations. We combine Gaia distances with spectra from the Hubble and FUSE satelites to make precise tests of the white dwarf mass-radius relation.
Invited article: Time accurate mass flow measurements of solid-fueled systems.
Olliges, Jordan D; Lilly, Taylor C; Joslyn, Thomas B; Ketsdever, Andrew D
2008-10-01
A novel diagnostic method is described that utilizes a thrust stand mass balance (TSMB) to directly measure time-accurate mass flow from a solid-fuel thruster. The accuracy of the TSMB mass flow measurement technique was demonstrated in three ways including the use of an idealized numerical simulation, verifying a fluid mass calibration with high-speed digital photography, and by measuring mass loss in more than 30 hybrid rocket motor firings. Dynamic response of the mass balance was assessed through weight calibration and used to derive spring, damping, and mass moment of inertia coefficients for the TSMB. These dynamic coefficients were used to determine the mass flow rate and total mass loss within an acrylic and gaseous oxygen hybrid rocket motor firing. Intentional variations in the oxygen flow rate resulted in corresponding variations in the total propellant mass flow as expected. The TSMB was optimized to determine mass losses of up to 2.5 g and measured total mass loss to within 2.5% of that calculated by a NIST-calibrated digital scale. Using this method, a mass flow resolution of 0.0011 g/s or 2% of the average mass flow in this study has been achieved.
Invited Article: Time accurate mass flow measurements of solid-fueled systems
NASA Astrophysics Data System (ADS)
Olliges, Jordan D.; Lilly, Taylor C.; Joslyn, Thomas B.; Ketsdever, Andrew D.
2008-10-01
A novel diagnostic method is described that utilizes a thrust stand mass balance (TSMB) to directly measure time-accurate mass flow from a solid-fuel thruster. The accuracy of the TSMB mass flow measurement technique was demonstrated in three ways including the use of an idealized numerical simulation, verifying a fluid mass calibration with high-speed digital photography, and by measuring mass loss in more than 30 hybrid rocket motor firings. Dynamic response of the mass balance was assessed through weight calibration and used to derive spring, damping, and mass moment of inertia coefficients for the TSMB. These dynamic coefficients were used to determine the mass flow rate and total mass loss within an acrylic and gaseous oxygen hybrid rocket motor firing. Intentional variations in the oxygen flow rate resulted in corresponding variations in the total propellant mass flow as expected. The TSMB was optimized to determine mass losses of up to 2.5 g and measured total mass loss to within 2.5% of that calculated by a NIST-calibrated digital scale. Using this method, a mass flow resolution of 0.0011 g/s or 2% of the average mass flow in this study has been achieved.
Optical measurements of paintings and the creation of an artwork database for authenticity
Hwang, Seonhee; Song, Hyerin; Cho, Soon-Woo; Kim, Chang Eun; Kim, Chang-Seok; Kim, Kyujung
2017-01-01
Paintings have high cultural and commercial value, so that needs to be preserved. Many techniques have been attempted to analyze properties of paintings, including X-ray analysis and optical coherence tomography (OCT) methods, and enable conservation of paintings from forgeries. In this paper, we suggest a simple and accurate optical analysis system to protect them from counterfeit which is comprised of fiber optics reflectance spectroscopy (FORS) and line laser-based topographic analysis. The system is designed to fully cover the whole area of paintings regardless of its size for the accurate analysis. For additional assessments, a line laser-based high resolved OCT was utilized. Some forgeries were created by the experts from the three different styles of genuine paintings for the experiments. After measuring surface properties of paintings, we could observe the results from the genuine works and the forgeries have the distinctive characteristics. The forgeries could be distinguished maximally 76.5% with obtained RGB spectra by FORS and 100% by topographic analysis. Through the several executions, the reliability of the system was confirmed. We could verify that the measurement system is worthwhile for the conservation of the valuable paintings. To store the surface information of the paintings in micron scale, we created a numerical database. Consequently, we secured the databases of three different famous Korean paintings for accurate authenticity. PMID:28151981
Optical measurements of paintings and the creation of an artwork database for authenticity.
Hwang, Seonhee; Song, Hyerin; Cho, Soon-Woo; Kim, Chang Eun; Kim, Chang-Seok; Kim, Kyujung
2017-01-01
Paintings have high cultural and commercial value, so that needs to be preserved. Many techniques have been attempted to analyze properties of paintings, including X-ray analysis and optical coherence tomography (OCT) methods, and enable conservation of paintings from forgeries. In this paper, we suggest a simple and accurate optical analysis system to protect them from counterfeit which is comprised of fiber optics reflectance spectroscopy (FORS) and line laser-based topographic analysis. The system is designed to fully cover the whole area of paintings regardless of its size for the accurate analysis. For additional assessments, a line laser-based high resolved OCT was utilized. Some forgeries were created by the experts from the three different styles of genuine paintings for the experiments. After measuring surface properties of paintings, we could observe the results from the genuine works and the forgeries have the distinctive characteristics. The forgeries could be distinguished maximally 76.5% with obtained RGB spectra by FORS and 100% by topographic analysis. Through the several executions, the reliability of the system was confirmed. We could verify that the measurement system is worthwhile for the conservation of the valuable paintings. To store the surface information of the paintings in micron scale, we created a numerical database. Consequently, we secured the databases of three different famous Korean paintings for accurate authenticity.
Tourassi, Georgia D; Harrawood, Brian; Singh, Swatee; Lo, Joseph Y; Floyd, Carey E
2007-01-01
The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tourassi, Georgia D.; Harrawood, Brian; Singh, Swatee
The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrievalmore » precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.« less
Cheng, Keding; Chui, Huixia; Domish, Larissa; Sloan, Angela; Hernandez, Drexler; McCorrister, Stuart; Robinson, Alyssia; Walker, Matthew; Peterson, Lorea A M; Majcher, Miles; Ratnam, Sam; Haldane, David J M; Bekal, Sadjia; Wylie, John; Chui, Linda; Tyler, Shaun; Xu, Bianli; Reimer, Aleisha; Nadon, Celine; Knox, J David; Wang, Gehua
2016-08-01
Mass spectrometry-based phenotypic H-antigen typing (MS-H) combined with whole-genome-sequencing-based genetic identification of H antigens, O antigens, and toxins (WGS-HOT) was used to type 60 clinical Escherichia coli isolates, 43 of which were previously identified as nonmotile, H type undetermined, or O rough by serotyping or having shown discordant MS-H and serotyping results. Whole-genome sequencing confirmed that MS-H was able to provide more accurate data regarding H antigen expression than serotyping. Further, enhanced and more confident O antigen identification resulted from gene cluster based typing in combination with conventional typing based on the gene pair comprising wzx and wzy and that comprising wzm and wzt The O antigen was identified in 94.6% of the isolates when the two genetic O typing approaches (gene pair and gene cluster) were used in conjunction, in comparison to 78.6% when the gene pair database was used alone. In addition, 98.2% of the isolates showed the existence of genes for various toxins and/or virulence factors, among which verotoxins (Shiga toxin 1 and/or Shiga toxin 2) were 100% concordant with conventional PCR based testing results. With more applications of mass spectrometry and whole-genome sequencing in clinical microbiology laboratories, this combined phenotypic and genetic typing platform (MS-H plus WGS-HOT) should be ideal for pathogenic E. coli typing. Copyright © 2016 Cheng et al.
Zhang, Jialing; Rector, John; Lin, John Q.; Young, Jonathan H.; Sans, Marta; Katta, Nitesh; Giese, Noah; Yu, Wendong; Nagi, Chandandeep; Suliburk, James; Liu, Jinsong; Bensussan, Alena; DeHoog, Rachel J.; Garza, Kyana Y.; Ludolph, Benjamin; Sorace, Anna G.; Syed, Anum; Zahedivash, Aydin; Milner, Thomas E.; Eberlin, Livia S.
2018-01-01
Conventional methods for histopathologic tissue diagnosis are labor- and time-intensive and can delay decision-making during diagnostic and therapeutic procedures. We report the development of an automated and biocompatible handheld mass spectrometry device for rapid and nondestructive diagnosis of human cancer tissues. The device, named MasSpec Pen, enables controlled and automated delivery of a discrete water droplet to a tissue surface for efficient extraction of biomolecules. We used the MasSpec Pen for ex vivo molecular analysis of 20 human cancer thin tissue sections and 253 human patient tissue samples including normal and cancerous tissues from breast, lung, thyroid, and ovary. The mass spectra obtained presented rich molecular profiles characterized by a variety of potential cancer biomarkers identified as metabolites, lipids, and proteins. Statistical classifiers built from the histologically validated molecular database allowed cancer prediction with high sensitivity (96.4%), specificity (96.2%), and overall accuracy (96.3%), as well as prediction of benign and malignant thyroid tumors and different histologic subtypes of lung cancer. Notably, our classifier allowed accurate diagnosis of cancer in marginal tumor regions presenting mixed histologic composition. Last, we demonstrate that the MasSpec Pen is suited for in vivo cancer diagnosis during surgery performed in tumor-bearing mouse models, without causing any observable tissue harm or stress to the animal. Our results provide evidence that the MasSpec Pen could potentially be used as a clinical and intraoperative technology for ex vivo and in vivo cancer diagnosis. PMID:28878011
He, Qiqi; Wang, Hanzhang; Kenyon, Jonathan; Liu, Guiming; Yang, Li; Tian, Junqiang; Yue, Zhongjin; Wang, Zhiping
2015-01-01
To use meta-analysis to determine the accuracy of percutaneous core needle biopsy in the diagnosis of small renal masses (SMRs ≤ 4.0 cm). Studies were identified by searching PubMed, Embase, and the Cochrane Library database up to March 2013. Two of the authors independently assessed the study quality using QUADAS-2 tool and extracted data that met the inclusion criteria. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and also summary receiver operating characteristic (SROC) curve were investigated and draw. Deek's funnel plot was used to evaluate the publication bias. A total of 9 studies with 788 patients (803 biopsies) were included. Failed biopsies without repeated or aborted from follow-up/surgery result were excluded (232 patients and 353 biopsies). For all cases, the pooled sensitivity was 94.0% (95% CI: 91.0%, 95.0%), the pooled positive likelihood was 22.57 (95 % CI: 9.20-55.34), the pooled negative likelihood was 0.09 (95 % CI: 0.06-0.13), the pooled DOR was 296.52(95 % CI: 99. 42-884.38). The area under the curve of SROC analysis was 0.959 ± 0.0254. Imaging-guided percutaneous core needle biopsy of small renal masses (SMRs ≤ 4.0 cm) is highly accurate to malignant tumor diagnosis with unknown metastatic status and could be offered to some patients after clinic judgment prior to surgical intervention consideration.
Wang, Jian; Anania, Veronica G.; Knott, Jeff; Rush, John; Lill, Jennie R.; Bourne, Philip E.; Bandeira, Nuno
2014-01-01
The combination of chemical cross-linking and mass spectrometry has recently been shown to constitute a powerful tool for studying protein–protein interactions and elucidating the structure of large protein complexes. However, computational methods for interpreting the complex MS/MS spectra from linked peptides are still in their infancy, making the high-throughput application of this approach largely impractical. Because of the lack of large annotated datasets, most current approaches do not capture the specific fragmentation patterns of linked peptides and therefore are not optimal for the identification of cross-linked peptides. Here we propose a generic approach to address this problem and demonstrate it using disulfide-bridged peptide libraries to (i) efficiently generate large mass spectral reference data for linked peptides at a low cost and (ii) automatically train an algorithm that can efficiently and accurately identify linked peptides from MS/MS spectra. We show that using this approach we were able to identify thousands of MS/MS spectra from disulfide-bridged peptides through comparison with proteome-scale sequence databases and significantly improve the sensitivity of cross-linked peptide identification. This allowed us to identify 60% more direct pairwise interactions between the protein subunits in the 20S proteasome complex than existing tools on cross-linking studies of the proteasome complexes. The basic framework of this approach and the MS/MS reference dataset generated should be valuable resources for the future development of new tools for the identification of linked peptides. PMID:24493012
[Genetic mutation databases: stakes and perspectives for orphan genetic diseases].
Humbertclaude, V; Tuffery-Giraud, S; Bareil, C; Thèze, C; Paulet, D; Desmet, F-O; Hamroun, D; Baux, D; Girardet, A; Collod-Béroud, G; Khau Van Kien, P; Roux, A-F; des Georges, M; Béroud, C; Claustres, M
2010-10-01
New technologies, which constantly become available for mutation detection and gene analysis, have contributed to an exponential rate of discovery of disease genes and variation in the human genome. The task of collecting and documenting this enormous amount of data in genetic databases represents a major challenge for the future of biological and medical science. The Locus Specific Databases (LSDBs) are so far the most efficient mutation databases. This review presents the main types of databases available for the analysis of mutations responsible for genetic disorders, as well as open perspectives for new therapeutic research or challenges for future medicine. Accurate and exhaustive collection of variations in human genomes will be crucial for research and personalized delivery of healthcare. Copyright © 2009 Elsevier Masson SAS. All rights reserved.
Montskó, Gergely; Tarjányi, Zita; Mezősi, Emese; Kovács, Gábor L
2014-04-01
Blood cortisol level is routinely analysed in laboratory medicine, but the immunoassays in widespread use have the disadvantage of cross-reactivity with some commonly used steroid drugs. Mass spectrometry has become a method of increasing importance for cortisol estimation. However, current methods do not offer the option of accurate mass identification. Our objective was to develop a mass spectrometry method to analyse salivary, serum total, and serum free cortisol via accurate mass identification. The analysis was performed on a Bruker micrOTOF high-resolution mass spectrometer. Sample preparation involved protein precipitation, serum ultrafiltration, and solid-phase extraction. Limit of quantification was 12.5 nmol L(-1) for total cortisol, 440 pmol L(-1) for serum ultrafiltrate, and 600 pmol L(-1) for saliva. Average intra-assay variation was 4.7%, and inter-assay variation was 6.6%. Mass accuracy was <2.5 ppm. Serum total cortisol levels were in the range 35.6-1088 nmol L(-1), and serum free cortisol levels were in the range 0.5-12.4 nmol L(-1). Salivary cortisol levels were in the range 0.7-10.4 nmol L(-1). Mass accuracy was equal to or below 2.5 ppm, resulting in a mass error less than 1 mDa and thus providing high specificity. We did not observe any interference with routinely used steroidal drugs. The method is capable of specific cortisol quantification in different matrices on the basis of accurate mass identification.
ION COMPOSITION ELUCIDATION (ICE)
Ion Composition Elucidation (ICE) utilizes selected ion recording with a double focusing mass spectrometer to simultaneously determine exact masses and relative isotopic abundances from mass peak profiles. These can be determined more accurately and at higher sensitivity ...
Allmer, Jens; Kuhlgert, Sebastian; Hippler, Michael
2008-07-07
The amount of information stemming from proteomics experiments involving (multi dimensional) separation techniques, mass spectrometric analysis, and computational analysis is ever-increasing. Data from such an experimental workflow needs to be captured, related and analyzed. Biological experiments within this scope produce heterogenic data ranging from pictures of one or two-dimensional protein maps and spectra recorded by tandem mass spectrometry to text-based identifications made by algorithms which analyze these spectra. Additionally, peptide and corresponding protein information needs to be displayed. In order to handle the large amount of data from computational processing of mass spectrometric experiments, automatic import scripts are available and the necessity for manual input to the database has been minimized. Information is in a generic format which abstracts from specific software tools typically used in such an experimental workflow. The software is therefore capable of storing and cross analysing results from many algorithms. A novel feature and a focus of this database is to facilitate protein identification by using peptides identified from mass spectrometry and link this information directly to respective protein maps. Additionally, our application employs spectral counting for quantitative presentation of the data. All information can be linked to hot spots on images to place the results into an experimental context. A summary of identified proteins, containing all relevant information per hot spot, is automatically generated, usually upon either a change in the underlying protein models or due to newly imported identifications. The supporting information for this report can be accessed in multiple ways using the user interface provided by the application. We present a proteomics database which aims to greatly reduce evaluation time of results from mass spectrometric experiments and enhance result quality by allowing consistent data handling. Import functionality, automatic protein detection, and summary creation act together to facilitate data analysis. In addition, supporting information for these findings is readily accessible via the graphical user interface provided. The database schema and the implementation, which can easily be installed on virtually any server, can be downloaded in the form of a compressed file from our project webpage.
Habachi, A El; Conil, E; Hadjem, A; Vazquez, E; Wong, M F; Gati, A; Fleury, G; Wiart, J
2010-04-07
In this paper, we propose identification of the morphological factors that may impact the whole-body averaged specific absorption rate (WBSAR). This study is conducted for the case of exposure to a front plane wave at a 2100 MHz frequency carrier. This study is based on the development of different regression models for estimating the WBSAR as a function of morphological factors. For this purpose, a database of 12 anatomical human models (phantoms) has been considered. Also, 18 supplementary phantoms obtained using the morphing technique were generated to build the required relation. This paper presents three models based on external morphological factors such as the body surface area, the body mass index or the body mass. These models show good results in estimating the WBSAR (<10%) for families obtained by the morphing technique, but these are still less accurate (30%) when applied to different original phantoms. This study stresses the importance of the internal morphological factors such as muscle and fat proportions in characterization of the WBSAR. The regression models are then improved using internal morphological factors with an estimation error of approximately 10% on the WBSAR. Finally, this study is suitable for establishing the statistical distribution of the WBSAR for a given population characterized by its morphology.
NASA Astrophysics Data System (ADS)
El Habachi, A.; Conil, E.; Hadjem, A.; Vazquez, E.; Wong, M. F.; Gati, A.; Fleury, G.; Wiart, J.
2010-04-01
In this paper, we propose identification of the morphological factors that may impact the whole-body averaged specific absorption rate (WBSAR). This study is conducted for the case of exposure to a front plane wave at a 2100 MHz frequency carrier. This study is based on the development of different regression models for estimating the WBSAR as a function of morphological factors. For this purpose, a database of 12 anatomical human models (phantoms) has been considered. Also, 18 supplementary phantoms obtained using the morphing technique were generated to build the required relation. This paper presents three models based on external morphological factors such as the body surface area, the body mass index or the body mass. These models show good results in estimating the WBSAR (<10%) for families obtained by the morphing technique, but these are still less accurate (30%) when applied to different original phantoms. This study stresses the importance of the internal morphological factors such as muscle and fat proportions in characterization of the WBSAR. The regression models are then improved using internal morphological factors with an estimation error of approximately 10% on the WBSAR. Finally, this study is suitable for establishing the statistical distribution of the WBSAR for a given population characterized by its morphology.
Popping, Bert; De Dominicis, Emiliano; Dante, Mario; Nocetti, Marco
2017-02-16
Parmigiano Reggiano is an Italian product with a protected designation of origin (P.D.O.). It is an aged hard cheese made from raw milk. P.D.O. products are protected by European regulations. Approximately 3 million wheels are produced each year, and the product attracts a relevant premium price due to its quality and all around the world well known typicity. Due to the high demand that exceeds the production, several fraudulent products can be found on the market. The rate of fraud is estimated between 20% and 40%, the latter predominantly in the grated form. We have developed a non-target method based on Liquid Chomatography-High Resolution Mass Spectrometry (LC-HRMS) that allows the discrimination of Parmigiano Reggiano from non-authentic products with milk from different geographical origins or products, where other aspects of the production process do not comply with the rules laid down in the production specifications for Parmeggiano Reggiano. Based on a database created with authentic samples provided by the Consortium of Parmigiano Reggiano Cheese, a reliable classification model was built. The overall classification capabilities of this non-targeted method was verified on 32 grated cheese samples. The classification was 87.5% accurate.
Mahieu, Nathaniel G; Patti, Gary J
2017-10-03
When using liquid chromatography/mass spectrometry (LC/MS) to perform untargeted metabolomics, it is now routine to detect tens of thousands of features from biological samples. Poor understanding of the data, however, has complicated interpretation and masked the number of unique metabolites actually being measured in an experiment. Here we place an upper bound on the number of unique metabolites detected in Escherichia coli samples analyzed with one untargeted metabolomics method. We first group multiple features arising from the same analyte, which we call "degenerate features", using a context-driven annotation approach. Surprisingly, this analysis revealed thousands of previously unreported degeneracies that reduced the number of unique analytes to ∼2961. We then applied an orthogonal approach to remove nonbiological features from the data using the 13 C-based credentialing technology. This further reduced the number of unique analytes to less than 1000. Our 90% reduction in data is 5-fold greater than previously published studies. On the basis of the results, we propose an alternative approach to untargeted metabolomics that relies on thoroughly annotated reference data sets. To this end, we introduce the creDBle database ( http://creDBle.wustl.edu ), which contains accurate mass, retention time, and MS/MS fragmentation data as well as annotations of all credentialed features.
The development of an annotated library of neutral human milk oligosaccharides
Wu, Shuai; Tao, Nannan; German, J. Bruce; Grimm, Rudolf; Lebrilla, Carlito B.
2010-01-01
Human milk oligosaccharides (HMOs)a perform a number of functions including serving as prebiotics to stimulate the growth of beneficial intestinal bacteria, as receptor analogs to inhibit binding of pathogens, and as substances that promote postnatal brain development. There is further evidence that HMOs participate in modulating the human immune system. Because the absorption, catabolism and biological function of oligosaccharides (OS) have strong correlations with their structures, structure elucidation is key to advancing this research. Oligosaccharides are produced by competing enzymes that provide the large structural diversity and heterogeneity that characterizes this class of compounds. Unlike the proteome, there is no template for oligosaccharides making it difficult to rapidly identify oligosaccharide structures. In this research, the annotation of the neutral free oligosaccharides in milk is performed to develop a database for the rapid identification of oligosaccharide structures. Our strategy incorporates high performance nanoflow liquid chromatography and mass spectrometry for characterizing HMO structures. HPLC-Chip/TOF MS provides a sensitive and quantitative method for sample profiling. The reproducible retention time and accurate mass can be used to rapidly identify the OS structures in HMO samples. A library with 45 neutral OS structures has been constructed. The structures include information regarding the epitopes such as Lewis type as well as information regarding the secretor status. PMID:20578730
Yates, John R
2015-11-01
Advances in computer technology and software have driven developments in mass spectrometry over the last 50 years. Computers and software have been impactful in three areas: the automation of difficult calculations to aid interpretation, the collection of data and control of instruments, and data interpretation. As the power of computers has grown, so too has the utility and impact on mass spectrometers and their capabilities. This has been particularly evident in the use of tandem mass spectrometry data to search protein and nucleotide sequence databases to identify peptide and protein sequences. This capability has driven the development of many new approaches to study biological systems, including the use of "bottom-up shotgun proteomics" to directly analyze protein mixtures. Graphical Abstract ᅟ.
Code of Federal Regulations, 2011 CFR
2011-01-01
... granted access approval by the Administrator or the HHS Secretary; (4) Information about all entries into... records and databases created under this part are accurate, have controlled access, and that their...
Accurate wavelengths for X-ray spectroscopy and the NIST hydrogen-like ion database
NASA Astrophysics Data System (ADS)
Kotochigova, S. A.; Kirby, K. P.; Brickhouse, N. S.; Mohr, P. J.; Tupitsyn, I. I.
2005-06-01
We have developed an ab initio multi-configuration Dirac-Fock-Sturm method for the precise calculation of X-ray emission spectra, including energies, transition wavelengths and transition probabilities. The calculations are based on non-orthogonal basis sets, generated by solving the Dirac-Fock and Dirac-Fock-Sturm equations. Inclusion of Sturm functions into the basis set provides an efficient description of correlation effects in highly charged ions and fast convergence of the configuration interaction procedure. A second part of our study is devoted to developing a theoretical procedure and creating an interactive database to generate energies and transition frequencies for hydrogen-like ions. This procedure is highly accurate and based on current knowledge of the relevant theory, which includes relativistic, quantum electrodynamic, recoil, and nuclear size effects.
New Data Bases and Standards for Gravity Anomalies
NASA Astrophysics Data System (ADS)
Keller, G. R.; Hildenbrand, T. G.; Webring, M. W.; Hinze, W. J.; Ravat, D.; Li, X.
2008-12-01
Ever since the use of high-precision gravimeters emerged in the 1950's, gravity surveys have been an important tool for geologic studies. Recent developments that make geologically useful measurements from airborne and satellite platforms, the ready availability of the Global Positioning System that provides precise vertical and horizontal control, improved global data bases, and the increased availability of processing and modeling software have accelerated the use of the gravity method. As a result, efforts are being made to improve the gravity databases publicly available to the geoscience community by expanding their holdings and increasing the accuracy and precision of the data in them. Specifically the North American Gravity Database as well as the individual databases of Canada, Mexico, and the United States are being revised using new formats and standards to improve their coverage, standardization, and accuracy. An important part of this effort is revision of procedures and standards for calculating gravity anomalies taking into account the enhanced computational power available, modern satellite-based positioning technology, improved terrain databases, and increased interest in more accurately defining the different components of gravity anomalies. The most striking revision is the use of one single internationally accepted reference ellipsoid for the horizontal and vertical datums of gravity stations as well as for the computation of the calculated value of theoretical gravity. The new standards hardly impact the interpretation of local anomalies, but do improve regional anomalies in that long wavelength artifacts are removed. Most importantly, such new standards can be consistently applied to gravity database compilations of nations, continents, and even the entire world. Although many types of gravity anomalies have been described, they fall into three main classes. The primary class incorporates planetary effects, which are analytically prescribed, to derive the predicted or modeled gravity, and thus, anomalies of this class are termed planetary. The most primitive version of a gravity anomaly is simply the difference between the value of gravity predicted by the effect of the reference ellipsoid and the observed gravity anomaly. When the height of the gravity station increases, the ellipsoidal gravity anomaly decreases because of the increased distance of measurement from the anomaly- producing masses. The two primary anomalies in geophysics, which are appropriately classified as planetary anomalies, are the Free-air and Bouguer gravity anomalies. They employ models that account for planetary effects on gravity including the topography of the earth. A second class of anomaly, geological anomalies, includes the modeled gravity effect of known or assumed masses leading to the predicted gravity by using geological data such as densities and crustal thickness. The third class of anomaly, filtered anomalies, removes arbitrary gravity effects of largely unknown sources that are empirically or analytically determined from the nature of the gravity anomalies by filtering.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castillo, Nancy I.; Ibáñez, María; Beltrán, Eduardo
Mold deterioration of historical documents in archives and libraries is a frequent and complex phenomenon that may have important economic and cultural consequences. In addition, exposure to toxic fungal metabolites might produce health problems. In this work, samples of broths of fungal species isolated from the documentary material and from indoor environmental samples of the Archive of Bogotá have been analyzed to investigate the presence of mycotoxins. High resolution mass spectrometry made possible to search for a large number of mycotoxins, even without reference standards available at the laboratory. For this purpose, a screening strategy based on ultra-high pressure liquidmore » chromatography coupled to quadrupole-time of flight mass spectrometry (UHPLC–QTOF MS) under MS{sup E} mode was applied. A customized home-made database containing elemental composition for around 600 mycotoxins was compiled. The presence of the (de)protonated molecule measured at its accurate mass was evaluated in the samples. When a peak was detected, collision induced dissociation fragments and characteristic isotopic ions were also evaluated and used for tentative identification, based on structure compatibility and comparison with literature data (if existing). Up to 44 mycotoxins were tentatively identified by UHPLC–QTOF MS. 34 of these tentative compounds were confirmed by subsequent analysis using a targeted LC–MS/MS method, supporting the strong potential of QTOF MS for identification/elucidation purposes. The presence of mycotoxins in these samples might help to reinforce safety measures for researchers and staff who work on reception, restoration and conservation of archival material, not only at the Archive of Bogotá but worldwide. - Highlights: • Mold deterioration of historical documents is a frequent and complex phenomenon. • Samples of broths of fungal species isolated from Archive of Bogotá analyzed. • UHPLC–QTOF MS (MS{sup E}) applied for mycotoxins screening, without reference standards. • Customized home-made database for around 600 mycotoxins compiled. • 44 mycotoxins tentatively identified, 34 of which confirmed by LC–MS/MS.« less
Li, Guo-Zhong; Vissers, Johannes P C; Silva, Jeffrey C; Golick, Dan; Gorenstein, Marc V; Geromanos, Scott J
2009-03-01
A novel database search algorithm is presented for the qualitative identification of proteins over a wide dynamic range, both in simple and complex biological samples. The algorithm has been designed for the analysis of data originating from data independent acquisitions, whereby multiple precursor ions are fragmented simultaneously. Measurements used by the algorithm include retention time, ion intensities, charge state, and accurate masses on both precursor and product ions from LC-MS data. The search algorithm uses an iterative process whereby each iteration incrementally increases the selectivity, specificity, and sensitivity of the overall strategy. Increased specificity is obtained by utilizing a subset database search approach, whereby for each subsequent stage of the search, only those peptides from securely identified proteins are queried. Tentative peptide and protein identifications are ranked and scored by their relative correlation to a number of models of known and empirically derived physicochemical attributes of proteins and peptides. In addition, the algorithm utilizes decoy database techniques for automatically determining the false positive identification rates. The search algorithm has been tested by comparing the search results from a four-protein mixture, the same four-protein mixture spiked into a complex biological background, and a variety of other "system" type protein digest mixtures. The method was validated independently by data dependent methods, while concurrently relying on replication and selectivity. Comparisons were also performed with other commercially and publicly available peptide fragmentation search algorithms. The presented results demonstrate the ability to correctly identify peptides and proteins from data independent acquisition strategies with high sensitivity and specificity. They also illustrate a more comprehensive analysis of the samples studied; providing approximately 20% more protein identifications, compared to a more conventional data directed approach using the same identification criteria, with a concurrent increase in both sequence coverage and the number of modified peptides.
Most compounds are not found in mass spectral libraries and must be identified by other means. Often, compound identities can be deduced from the compositions of the ions in their mass spectra and review of the chemical literature. Confirmation is provided by mass spectra and r...
Review of Spatial-Database System Usability: Recommendations for the ADDNS Project
2007-12-01
basic GIS background information , with a closer look at spatial databases. A GIS is also a computer- based system designed to capture, manage...foundation for deploying enterprise-wide spatial information systems . According to Oracle® [18], it enables accurate delivery of location- based services...Toronto TR 2007-141 Lanter, D.P. (1991). Design of a lineage- based meta-data base for GIS. Cartography and Geographic Information Systems , 18
A Knowledge Database on Thermal Control in Manufacturing Processes
NASA Astrophysics Data System (ADS)
Hirasawa, Shigeki; Satoh, Isao
A prototype version of a knowledge database on thermal control in manufacturing processes, specifically, molding, semiconductor manufacturing, and micro-scale manufacturing has been developed. The knowledge database has search functions for technical data, evaluated benchmark data, academic papers, and patents. The database also displays trends and future roadmaps for research topics. It has quick-calculation functions for basic design. This paper summarizes present research topics and future research on thermal control in manufacturing engineering to collate the information to the knowledge database. In the molding process, the initial mold and melt temperatures are very important parameters. In addition, thermal control is related to many semiconductor processes, and the main parameter is temperature variation in wafers. Accurate in-situ temperature measurment of wafers is important. And many technologies are being developed to manufacture micro-structures. Accordingly, the knowledge database will help further advance these technologies.
Doubling down on peptide phosphorylation as a variable mass modification
USDA-ARS?s Scientific Manuscript database
Some mass spectrometrists believe that searching for variable post-translational modifications like phosphorylation of serine or threonine when using database-search algorithms to interpret peptide tandem mass spectra will increase false positive rates. The basis for this is the premise that the al...
Brennan, T.M.; Hammons, B.E.; Tsao, J.Y.
1992-12-15
A method for on-line accurate monitoring and precise control of molecular beam epitaxial growth of Groups III-III-V or Groups III-V-V layers in an advanced semiconductor device incorporates reflection mass spectrometry. The reflection mass spectrometry is responsive to intentional perturbations in molecular fluxes incident on a substrate by accurately measuring the molecular fluxes reflected from the substrate. The reflected flux is extremely sensitive to the state of the growing surface and the measurements obtained enable control of newly forming surfaces that are dynamically changing as a result of growth. 3 figs.
Brennan, Thomas M.; Hammons, B. Eugene; Tsao, Jeffrey Y.
1992-01-01
A method for on-line accurate monitoring and precise control of molecular beam epitaxial growth of Groups III-III-V or Groups III-V-V layers in an advanced semiconductor device incorporates reflection mass spectrometry. The reflection mass spectrometry is responsive to intentional perturbations in molecular fluxes incident on a substrate by accurately measuring the molecular fluxes reflected from the substrate. The reflected flux is extremely sensitive to the state of the growing surface and the measurements obtained enable control of newly forming surfaces that are dynamically changing as a result of growth.
Identification and Quantitation of Flavanols and Proanthocyanidins in Foods: How Good are the Datas?
Kelm, Mark A.; Hammerstone, John F.; Schmitz, Harold H.
2005-01-01
Evidence suggesting that dietary polyphenols, flavanols, and proanthocyanidins in particular offer significant cardiovascular health benefits is rapidly increasing. Accordingly, reliable and accurate methods are needed to provide qualitative and quantitative food composition data necessary for high quality epidemiological and clinical research. Measurements for flavonoids and proanthocyanidins have employed a range of analytical techniques, with various colorimetric assays still being popular for estimating total polyphenolic content in foods and other biological samples despite advances made with more sophisticated analyses. More crudely, estimations of polyphenol content as well as antioxidant activity are also reported with values relating to radical scavenging activity. High-performance liquid chromatography (HPLC) is the method of choice for quantitative analysis of individual polyphenols such as flavanols and proanthocyanidins. Qualitative information regarding proanthocyanidin structure has been determined by chemical methods such as thiolysis and by HPLC-mass spectrometry (MS) techniques at present. The lack of appropriate standards is the single most important factor that limits the aforementioned analyses. However, with ever expanding research in the arena of flavanols, proanthocyanidins, and health and the importance of their future inclusion in food composition databases, the need for standards becomes more critical. At present, sufficiently well-characterized standard material is available for selective flavanols and proanthocyanidins, and construction of at least a limited food composition database is feasible. PMID:15712597
Automating Information Discovery Within the Invisible Web
NASA Astrophysics Data System (ADS)
Sweeney, Edwina; Curran, Kevin; Xie, Ermai
A Web crawler or spider crawls through the Web looking for pages to index, and when it locates a new page it passes the page on to an indexer. The indexer identifies links, keywords, and other content and stores these within its database. This database is searched by entering keywords through an interface and suitable Web pages are returned in a results page in the form of hyperlinks accompanied by short descriptions. The Web, however, is increasingly moving away from being a collection of documents to a multidimensional repository for sounds, images, audio, and other formats. This is leading to a situation where certain parts of the Web are invisible or hidden. The term known as the "Deep Web" has emerged to refer to the mass of information that can be accessed via the Web but cannot be indexed by conventional search engines. The concept of the Deep Web makes searches quite complex for search engines. Google states that the claim that conventional search engines cannot find such documents as PDFs, Word, PowerPoint, Excel, or any non-HTML page is not fully accurate and steps have been taken to address this problem by implementing procedures to search items such as academic publications, news, blogs, videos, books, and real-time information. However, Google still only provides access to a fraction of the Deep Web. This chapter explores the Deep Web and the current tools available in accessing it.
Impact of Accurate 30-Day Status on Operative Mortality: Wanted Dead or Alive, Not Unknown.
Ring, W Steves; Edgerton, James R; Herbert, Morley; Prince, Syma; Knoff, Cathy; Jenkins, Kristin M; Jessen, Michael E; Hamman, Baron L
2017-12-01
Risk-adjusted operative mortality is the most important quality metric in cardiac surgery for determining The Society of Thoracic Surgeons (STS) Composite Score for star ratings. Accurate 30-day status is required to determine STS operative mortality. The goal of this study was to determine the effect of unknown or missing 30-day status on risk-adjusted operative mortality in a regional STS Adult Cardiac Surgery Database cooperative and demonstrate the ability to correct these deficiencies by matching with an administrative database. STS Adult Cardiac Surgery Database data were submitted by 27 hospitals from five hospital systems to the Texas Quality Initiative (TQI), a regional quality collaborative. TQI data were matched with a regional hospital claims database to resolve unknown 30-day status. The risk-adjusted operative mortality observed-to-expected (O/E) ratio was determined before and after matching to determine the effect of unknown status on the operative mortality O/E. TQI found an excessive (22%) unknown 30-day status for STS isolated coronary artery bypass grafting cases. Matching the TQI data to the administrative claims database reduced the unknowns to 7%. The STS process of imputing unknown 30-day status as alive underestimates the true operative mortality O/E (1.27 before vs 1.30 after match), while excluding unknowns overestimates the operative mortality O/E (1.57 before vs 1.37 after match) for isolated coronary artery bypass grafting. The current STS algorithm of imputing unknown 30-day status as alive and a strategy of excluding cases with unknown 30-day status both result in erroneous calculation of operative mortality and operative mortality O/E. However, external validation by matching with an administrative database can improve the accuracy of clinical databases such as the STS Adult Cardiac Surgery Database. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
A kind of improved fingerprinting indoor location method based on WiFi
NASA Astrophysics Data System (ADS)
Zeng, Xi; Lin, Wei
2017-08-01
In the prior inventions, because of the complexity of the indoor environment, it is hard to guarantee position precision. In this paper provides an improved method that can be adopted to increase the indoor positioning accuracy of handheld positioning device. This method will be the direction of the handheld device position Angle and number of access points two characteristics to join the fingerprint. The two parameters make our normal fingerprint database more abundant. The positioning test results from comparing the normal fingerprint database with the improved fingerprint database prove the later positioning more accurate.
Researchermap: a tool for visualizing author locations using Google maps.
Rastegar-Mojarad, Majid; Bales, Michael E; Yu, Hong
2013-01-01
We hereby present ResearcherMap, a tool to visualize locations of authors of scholarly papers. In response to a query, the system returns a map of author locations. To develop the system we first populated a database of author locations, geocoding institution locations for all available institutional affiliation data in our database. The database includes all authors of Medline papers from 1990 to 2012. We conducted a formative heuristic usability evaluation of the system and measured the system's accuracy and performance. The accuracy of finding the accurate address is 97.5% in our system.
A rotorcraft flight database for validation of vision-based ranging algorithms
NASA Technical Reports Server (NTRS)
Smith, Phillip N.
1992-01-01
A helicopter flight test experiment was conducted at the NASA Ames Research Center to obtain a database consisting of video imagery and accurate measurements of camera motion, camera calibration parameters, and true range information. The database was developed to allow verification of monocular passive range estimation algorithms for use in the autonomous navigation of rotorcraft during low altitude flight. The helicopter flight experiment is briefly described. Four data sets representative of the different helicopter maneuvers and the visual scenery encountered during the flight test are presented. These data sets will be made available to researchers in the computer vision community.
Realistic simulated MRI and SPECT databases. Application to SPECT/MRI registration evaluation.
Aubert-Broche, Berengere; Grova, Christophe; Reilhac, Anthonin; Evans, Alan C; Collins, D Louis
2006-01-01
This paper describes the construction of simulated SPECT and MRI databases that account for realistic anatomical and functional variability. The data is used as a gold-standard to evaluate four SPECT/MRI similarity-based registration methods. Simulation realism was accounted for using accurate physical models of data generation and acquisition. MRI and SPECT simulations were generated from three subjects to take into account inter-subject anatomical variability. Functional SPECT data were computed from six functional models of brain perfusion. Previous models of normal perfusion and ictal perfusion observed in Mesial Temporal Lobe Epilepsy (MTLE) were considered to generate functional variability. We studied the impact noise and intensity non-uniformity in MRI simulations and SPECT scatter correction may have on registration accuracy. We quantified the amount of registration error caused by anatomical and functional variability. Registration involving ictal data was less accurate than registration involving normal data. MR intensity nonuniformity was the main factor decreasing registration accuracy. The proposed simulated database is promising to evaluate many functional neuroimaging methods, involving MRI and SPECT data.
Basophile: Accurate Fragment Charge State Prediction Improves Peptide Identification Rates
Wang, Dong; Dasari, Surendra; Chambers, Matthew C.; ...
2013-03-07
In shotgun proteomics, database search algorithms rely on fragmentation models to predict fragment ions that should be observed for a given peptide sequence. The most widely used strategy (Naive model) is oversimplified, cleaving all peptide bonds with equal probability to produce fragments of all charges below that of the precursor ion. More accurate models, based on fragmentation simulation, are too computationally intensive for on-the-fly use in database search algorithms. We have created an ordinal-regression-based model called Basophile that takes fragment size and basic residue distribution into account when determining the charge retention during CID/higher-energy collision induced dissociation (HCD) of chargedmore » peptides. This model improves the accuracy of predictions by reducing the number of unnecessary fragments that are routinely predicted for highly-charged precursors. Basophile increased the identification rates by 26% (on average) over the Naive model, when analyzing triply-charged precursors from ion trap data. Basophile achieves simplicity and speed by solving the prediction problem with an ordinal regression equation, which can be incorporated into any database search software for shotgun proteomic identification.« less
Effect of Genetic Database Comprehensiveness on Fractional Proteomics of Escherichia coli O157:H7
2014-01-01
proteins would be observed in the extracellular fraction. 15. SUBJECT TERMS Escherichia coli O157:H7 Liquid chromatography Mass spectrometry...Preparation ...............1 2.2 Liquid Chromatography /Mass Spectrometry Sample Preparation ....................2 2.3 Liquid Chromatography /Mass... Chromatography /Mass Spectrometry Sample Preparation. Samples were prepared for liquid chromatography tandem mass spectrometry (LC-MS/MS) in a similar
Accurate LC peak boundary detection for ¹⁶O/¹⁸O labeled LC-MS data.
Cui, Jian; Petritis, Konstantinos; Tegeler, Tony; Petritis, Brianne; Ma, Xuepo; Jin, Yufang; Gao, Shou-Jiang S J; Zhang, Jianqiu Michelle
2013-01-01
In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements.
Accurate LC Peak Boundary Detection for 16 O/ 18 O Labeled LC-MS Data
Cui, Jian; Petritis, Konstantinos; Tegeler, Tony; Petritis, Brianne; Ma, Xuepo; Jin, Yufang; Gao, Shou-Jiang (SJ); Zhang, Jianqiu (Michelle)
2013-01-01
In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements. PMID:24115998
Kann, Maricel G.; Sheetlin, Sergey L.; Park, Yonil; Bryant, Stephen H.; Spouge, John L.
2007-01-01
The sequencing of complete genomes has created a pressing need for automated annotation of gene function. Because domains are the basic units of protein function and evolution, a gene can be annotated from a domain database by aligning domains to the corresponding protein sequence. Ideally, complete domains are aligned to protein subsequences, in a ‘semi-global alignment’. Local alignment, which aligns pieces of domains to subsequences, is common in high-throughput annotation applications, however. It is a mature technique, with the heuristics and accurate E-values required for screening large databases and evaluating the screening results. Hidden Markov models (HMMs) provide an alternative theoretical framework for semi-global alignment, but their use is limited because they lack heuristic acceleration and accurate E-values. Our new tool, GLOBAL, overcomes some limitations of previous semi-global HMMs: it has accurate E-values and the possibility of the heuristic acceleration required for high-throughput applications. Moreover, according to a standard of truth based on protein structure, two semi-global HMM alignment tools (GLOBAL and HMMer) had comparable performance in identifying complete domains, but distinctly outperformed two tools based on local alignment. When searching for complete protein domains, therefore, GLOBAL avoids disadvantages commonly associated with HMMs, yet maintains their superior retrieval performance. PMID:17596268
MetaPro-IQ: a universal metaproteomic approach to studying human and mouse gut microbiota.
Zhang, Xu; Ning, Zhibin; Mayne, Janice; Moore, Jasmine I; Li, Jennifer; Butcher, James; Deeke, Shelley Ann; Chen, Rui; Chiang, Cheng-Kang; Wen, Ming; Mack, David; Stintzi, Alain; Figeys, Daniel
2016-06-24
The gut microbiota has been shown to be closely associated with human health and disease. While next-generation sequencing can be readily used to profile the microbiota taxonomy and metabolic potential, metaproteomics is better suited for deciphering microbial biological activities. However, the application of gut metaproteomics has largely been limited due to the low efficiency of protein identification. Thus, a high-performance and easy-to-implement gut metaproteomic approach is required. In this study, we developed a high-performance and universal workflow for gut metaproteome identification and quantification (named MetaPro-IQ) by using the close-to-complete human or mouse gut microbial gene catalog as database and an iterative database search strategy. An average of 38 and 33 % of the acquired tandem mass spectrometry (MS) spectra was confidently identified for the studied mouse stool and human mucosal-luminal interface samples, respectively. In total, we accurately quantified 30,749 protein groups for the mouse metaproteome and 19,011 protein groups for the human metaproteome. Moreover, the MetaPro-IQ approach enabled comparable identifications with the matched metagenome database search strategy that is widely used but needs prior metagenomic sequencing. The response of gut microbiota to high-fat diet in mice was then assessed, which showed distinct metaproteome patterns for high-fat-fed mice and identified 849 proteins as significant responders to high-fat feeding in comparison to low-fat feeding. We present MetaPro-IQ, a metaproteomic approach for highly efficient intestinal microbial protein identification and quantification, which functions as a universal workflow for metaproteomic studies, and will thus facilitate the application of metaproteomics for better understanding the functions of gut microbiota in health and disease.
Matajira, Carlos E C; Moreno, Luisa Z; Gomes, Vasco T M; Silva, Ana Paula S; Mesquita, Renan E; Doto, Daniela S; Calderaro, Franco F; de Souza, Fernando N; Christ, Ana Paula G; Sato, Maria Inês Z; Moreno, Andrea M
2017-03-01
Traditional microbiological methods enable genus-level identification of Streptococcus spp. isolates. However, as the species of this genus show broad phenotypic variation, species-level identification or even differentiation within the genus is difficult. Herein we report the evaluation of protein spectra cluster analysis for the identification of Streptococcus species associated with disease in swine by means of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). A total of 250 S. suis-like isolates obtained from pigs with clinical signs of encephalitis, arthritis, pneumonia, metritis, and urinary or septicemic infection were studied. The isolates came from pigs in different Brazilian states from 2001 to 2014. The MALDI-TOF MS analysis identified 86% (215 of 250) as S. suis and 14% (35 of 250) as S. alactolyticus, S. dysgalactiae, S. gallinaceus, S. gallolyticus, S. gordonii, S. henryi, S. hyointestinalis, S. hyovaginalis, S. mitis, S. oralis, S. pluranimalium, and S. sanguinis. The MALDI-TOF MS identification was confirmed in 99.2% of the isolates by 16S rDNA sequencing, with MALDI-TOF MS misidentifying 2 S. pluranimalium as S. hyovaginalis. Isolates were also tested by a biochemical automated system that correctly identified all isolates of 8 of the 10 species in the database. Neither the isolates of the 3 species not in the database ( S. gallinaceus, S. henryi, and S. hyovaginalis) nor the isolates of 2 species that were in the database ( S. oralis and S. pluranimalium) could be identified. The topology of the protein spectra cluster analysis appears to sustain the species phylogenetic similarities, further supporting identification by MALDI-TOF MS examination as a rapid and accurate alternative to 16S rDNA sequencing.
NASA Astrophysics Data System (ADS)
Li, K. Betty; Goovaerts, Pierre; Abriola, Linda M.
2007-06-01
Contaminant mass discharge across a control plane downstream of a dense nonaqueous phase liquid (DNAPL) source zone has great potential to serve as a metric for the assessment of the effectiveness of source zone treatment technologies and for the development of risk-based source-plume remediation strategies. However, too often the uncertainty of mass discharge estimated in the field is not accounted for in the analysis. In this paper, a geostatistical approach is proposed to estimate mass discharge and to quantify its associated uncertainty using multilevel transect measurements of contaminant concentration (C) and hydraulic conductivity (K). The approach adapts the p-field simulation algorithm to propagate and upscale the uncertainty of mass discharge from the local uncertainty models of C and K. Application of this methodology to numerically simulated transects shows that, with a regular sampling pattern, geostatistics can provide an accurate model of uncertainty for the transects that are associated with low levels of source mass removal (i.e., transects that have a large percentage of contaminated area). For high levels of mass removal (i.e., transects with a few hot spots and large areas of near-zero concentration), a total sampling area equivalent to 6˜7% of the transect is required to achieve accurate uncertainty modeling. A comparison of the results for different measurement supports indicates that samples taken with longer screen lengths may lead to less accurate models of mass discharge uncertainty. The quantification of mass discharge uncertainty, in the form of a probability distribution, will facilitate risk assessment associated with various remediation strategies.
NASA Astrophysics Data System (ADS)
Sheynkman, Gloria M.; Shortreed, Michael R.; Cesnik, Anthony J.; Smith, Lloyd M.
2016-06-01
Mass spectrometry-based proteomics has emerged as the leading method for detection, quantification, and characterization of proteins. Nearly all proteomic workflows rely on proteomic databases to identify peptides and proteins, but these databases typically contain a generic set of proteins that lack variations unique to a given sample, precluding their detection. Fortunately, proteogenomics enables the detection of such proteomic variations and can be defined, broadly, as the use of nucleotide sequences to generate candidate protein sequences for mass spectrometry database searching. Proteogenomics is experiencing heightened significance due to two developments: (a) advances in DNA sequencing technologies that have made complete sequencing of human genomes and transcriptomes routine, and (b) the unveiling of the tremendous complexity of the human proteome as expressed at the levels of genes, cells, tissues, individuals, and populations. We review here the field of human proteogenomics, with an emphasis on its history, current implementations, the types of proteomic variations it reveals, and several important applications.
Hydra: a scalable proteomic search engine which utilizes the Hadoop distributed computing framework
2012-01-01
Background For shotgun mass spectrometry based proteomics the most computationally expensive step is in matching the spectra against an increasingly large database of sequences and their post-translational modifications with known masses. Each mass spectrometer can generate data at an astonishingly high rate, and the scope of what is searched for is continually increasing. Therefore solutions for improving our ability to perform these searches are needed. Results We present a sequence database search engine that is specifically designed to run efficiently on the Hadoop MapReduce distributed computing framework. The search engine implements the K-score algorithm, generating comparable output for the same input files as the original implementation. The scalability of the system is shown, and the architecture required for the development of such distributed processing is discussed. Conclusion The software is scalable in its ability to handle a large peptide database, numerous modifications and large numbers of spectra. Performance scales with the number of processors in the cluster, allowing throughput to expand with the available resources. PMID:23216909
Sheynkman, Gloria M.; Shortreed, Michael R.; Cesnik, Anthony J.; Smith, Lloyd M.
2016-01-01
Mass spectrometry–based proteomics has emerged as the leading method for detection, quantification, and characterization of proteins. Nearly all proteomic workflows rely on proteomic databases to identify peptides and proteins, but these databases typically contain a generic set of proteins that lack variations unique to a given sample, precluding their detection. Fortunately, proteogenomics enables the detection of such proteomic variations and can be defined, broadly, as the use of nucleotide sequences to generate candidate protein sequences for mass spectrometry database searching. Proteogenomics is experiencing heightened significance due to two developments: (a) advances in DNA sequencing technologies that have made complete sequencing of human genomes and transcriptomes routine, and (b) the unveiling of the tremendous complexity of the human proteome as expressed at the levels of genes, cells, tissues, individuals, and populations. We review here the field of human proteogenomics, with an emphasis on its history, current implementations, the types of proteomic variations it reveals, and several important applications. PMID:27049631
Hydra: a scalable proteomic search engine which utilizes the Hadoop distributed computing framework.
Lewis, Steven; Csordas, Attila; Killcoyne, Sarah; Hermjakob, Henning; Hoopmann, Michael R; Moritz, Robert L; Deutsch, Eric W; Boyle, John
2012-12-05
For shotgun mass spectrometry based proteomics the most computationally expensive step is in matching the spectra against an increasingly large database of sequences and their post-translational modifications with known masses. Each mass spectrometer can generate data at an astonishingly high rate, and the scope of what is searched for is continually increasing. Therefore solutions for improving our ability to perform these searches are needed. We present a sequence database search engine that is specifically designed to run efficiently on the Hadoop MapReduce distributed computing framework. The search engine implements the K-score algorithm, generating comparable output for the same input files as the original implementation. The scalability of the system is shown, and the architecture required for the development of such distributed processing is discussed. The software is scalable in its ability to handle a large peptide database, numerous modifications and large numbers of spectra. Performance scales with the number of processors in the cluster, allowing throughput to expand with the available resources.
Aiyetan, Paul; Zhang, Bai; Zhang, Zhen; Zhang, Hui
2014-01-01
Mass spectrometry based glycoproteomics has become a major means of identifying and characterizing previously N-linked glycan attached loci (glycosites). In the bottom-up approach, several factors which include but not limited to sample preparation, mass spectrometry analyses, and protein sequence database searches result in previously N-linked peptide spectrum matches (PSMs) of varying lengths. Given that multiple PSM scan map to a glycosite, we reason that identified PSMs are varying length peptide species of a unique set of glycosites. Because associated spectra of these PSMs are typically summed separately, true glycosite associated spectra counts are lost or complicated. Also, these varying length peptide species complicate protein inference as smaller sized peptide sequences are more likely to map to more proteins than larger sized peptides or actual glycosite sequences. Here, we present XGlycScan. XGlycScan maps varying length peptide species to glycosites to facilitate an accurate quantification of glycosite associated spectra counts. We observed that this reduced the variability in reported identifications of mass spectrometry technical replicates of our sample dataset. We also observed that mapping identified peptides to glycosites provided an assessment of search-engine identification. Inherently, XGlycScan reported glycosites reduce the complexity in protein inference. We implemented XGlycScan in the platform independent Java programing language and have made it available as open source. XGlycScan's source code is freely available at https://bitbucket.org/paiyetan/xglycscan/src and its compiled binaries and documentation can be freely downloaded at https://bitbucket.org/paiyetan/xglycscan/downloads. The graphical user interface version can also be found at https://bitbucket.org/paiyetan/xglycscangui/src and https://bitbucket.org/paiyetan/xglycscangui/downloads respectively.
Microorganism Identification Based On MALDI-TOF-MS Fingerprints
NASA Astrophysics Data System (ADS)
Elssner, Thomas; Kostrzewa, Markus; Maier, Thomas; Kruppa, Gary
Advances in MALDI-TOF mass spectrometry have enabled the development of a rapid, accurate and specific method for the identification of bacteria directly from colonies picked from culture plates, which we have named the MALDI Biotyper. The picked colonies are placed on a target plate, a drop of matrix solution is added, and a pattern of protein molecular weights and intensities, "the protein fingerprint" of the bacteria, is produced by the MALDI-TOF mass spectrometer. The obtained protein mass fingerprint representing a molecular signature of the microorganism is then matched against a database containing a library of previously measured protein mass fingerprints, and scores for the match to every library entry are produced. An ID is obtained if a score is returned over a pre-set threshold. The sensitivity of the techniques is such that only approximately 104 bacterial cells are needed, meaning that an overnight culture is sufficient, and the results are obtained in minutes after culture. The improvement in time to result over biochemical methods, and the capability to perform a non-targeted identification of bacteria and spores, potentially makes this method suitable for use in the detect-to-treat timeframe in a bioterrorism event. In the case of white-powder samples, the infectious spore is present in sufficient quantity in the powder so that the MALDI Biotyper result can be obtained directly from the white powder, without the need for culture. While spores produce very different patterns from the vegetative colonies of the corresponding bacteria, this problem is overcome by simply including protein fingerprints of the spores in the library. Results on spores can be returned within minutes, making the method suitable for use in the "detect-to-protect" timeframe.
Khatun, Jainab; Hamlett, Eric; Giddings, Morgan C
2008-03-01
The identification of peptides by tandem mass spectrometry (MS/MS) is a central method of proteomics research, but due to the complexity of MS/MS data and the large databases searched, the accuracy of peptide identification algorithms remains limited. To improve the accuracy of identification we applied a machine-learning approach using a hidden Markov model (HMM) to capture the complex and often subtle links between a peptide sequence and its MS/MS spectrum. Our model, HMM_Score, represents ion types as HMM states and calculates the maximum joint probability for a peptide/spectrum pair using emission probabilities from three factors: the amino acids adjacent to each fragmentation site, the mass dependence of ion types and the intensity dependence of ion types. The Viterbi algorithm is used to calculate the most probable assignment between ion types in a spectrum and a peptide sequence, then a correction factor is added to account for the propensity of the model to favor longer peptides. An expectation value is calculated based on the model score to assess the significance of each peptide/spectrum match. We trained and tested HMM_Score on three data sets generated by two different mass spectrometer types. For a reference data set recently reported in the literature and validated using seven identification algorithms, HMM_Score produced 43% more positive identification results at a 1% false positive rate than the best of two other commonly used algorithms, Mascot and X!Tandem. HMM_Score is a highly accurate platform for peptide identification that works well for a variety of mass spectrometer and biological sample types. The program is freely available on ProteomeCommons via an OpenSource license. See http://bioinfo.unc.edu/downloads/ for the download link.
Methods for the development of a bioregenerative life support system
NASA Technical Reports Server (NTRS)
Goldman, Michelle; Gomez, Shawn; Voorhees, Mike
1990-01-01
Presented here is a rudimentary approach to designing a life support system based on the utilization of plants and animals. The biggest stumbling block in the initial phases of developing a bioregenerative life support system is encountered in collecting and consolidating the data. If a database existed for the systems engineer so that he or she may have accurate data and a better understanding of biological systems in engineering terms, then the design process would be simplified. Also addressed is a means of evaluating the subsystems chosen. These subsystems are unified into a common metric, kilograms of mass, and normalized in relation to the throughput of a few basic elements. The initial integration of these subsystems is based on input/output masses and eventually balanced to a point of operation within the inherent performance ranges of the organisms chosen. At this point, it becomes necessary to go beyond the simplifying assumptions of simple mass relationships and further define for each organism the processes used to manipulate the throughput matter. Mainly considered here is the fact that these organisms perform input/output functions on differing timescales, thus establishing the need for buffer volumes or appropriate subsystem phasing. At each point in a systematic design it is necessary to disturb the system and discern its sensitivity to the disturbance. This can be done either through the introduction of a catastrophic failure or by applying a small perturbation to the system. One example is increasing the crew size. Here the wide range of performance characteristics once again shows that biological systems have an inherent advantage in responding to systemic perturbations. Since the design of any space-based system depends on mass, power, and volume requirements, each subsystem must be evaluated in these terms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brechenmacher, Laurent; Nguyen, Tran H.; Hixson, Kim K.
Root hairs are a terminally differentiated single cell type, mainly involved in water and nutrient uptake from the soil. The soybean root hair cell represents an excellent model for the study of single cell systems biology. In this study, we identified 5702 proteins, with at least two peptides, from soybean root hairs using an accurate mass and time tag approach, establishing the most comprehensive proteome reference map of this single cell type. We also showed that trypsin is the most appropriate enzyme for soybean proteomic studies by performing an in silico digestion of the soybean proteome database using different proteases.more » Although the majority of proteins identified in this study are involved in basal metabolism, the function of others are more related to root hair formation/function and include proteins involved in nutrient uptake (transporters) or vesicular trafficking (cytoskeleton and RAB proteins). Interestingly, some of these proteins appear to be specifically expressed in root hairs and constitute very good candidates for further studies to elucidate unique features of this single cell model.« less
Monte Carlo calculations for reporting patient organ doses from interventional radiology
NASA Astrophysics Data System (ADS)
Huo, Wanli; Feng, Mang; Pi, Yifei; Chen, Zhi; Gao, Yiming; Xu, X. George
2017-09-01
This paper describes a project to generate organ dose data for the purposes of extending VirtualDose software from CT imaging to interventional radiology (IR) applications. A library of 23 mesh-based anthropometric patient phantoms were involved in Monte Carlo simulations for database calculations. Organ doses and effective doses of IR procedures with specific beam projection, filed of view (FOV) and beam quality for all parts of body were obtained. Comparing organ doses for different beam qualities, beam projections, patients' ages and patient's body mass indexes (BMIs) which generated by VirtualDose-IR, significant discrepancies were observed. For relatively long time exposure, IR doses depend on beam quality, beam direction and patient size. Therefore, VirtualDose-IR, which is based on the latest anatomically realistic patient phantoms, can generate accurate doses for IR treatment. It is suitable to apply this software in clinical IR dose management as an effective tool to estimate patient doses and optimize IR treatment plans.
Binary Lenses in OGLE-III EWS Database. Seasons 2002-2003
NASA Astrophysics Data System (ADS)
Jaroszynski, M.; Udalski, A.; Kubiak, M.; Szymanski, M.; Pietrzynski, G.; Soszynski, I.; Zebrun, K.; Szewczyk, O.; Wyrzykowski, L.
2004-06-01
We present 15 binary lens candidates from OGLE-III Early Warning System database for seasons 2002-2003. We also found 15 events interpreted as single mass lensing of double sources. The candidates were selected by visual light curves inspection. Examining the models of binary lenses of this and our previous study (10 caustic crossing events of OGLE-II seasons 1997--1999) we find one case of extreme mass ratio binary (q approx 0.005) and the rest in the range 0.1
Li, Xiaowen; Shen, Baohua; Jiang, Zheng; Huang, Yi; Zhuo, Xianyi
2013-08-09
A novel analytical toxicology method has been developed for the analysis of drugs of abuse in human urine by using a high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS). This method allows for the detection of different drugs of abuse, including amphetamines, cocaine, opiate alkaloids, cannabinoids, hallucinogens and their metabolites. After solid-phase extraction with Oasis HLB cartridges, spiked urine samples were analysed by HPLC/LTQ-Orbitrap-MS using an electrospray interface in positive ionisation mode, with resolving power of 30,000 full width at half maximum (FWHM). Gradient elution off of a Hypersil Gold PFP column (50mm×2.1mm) allowed to resolve 65 target compounds and 3 internal standards in a total chromatographic run time of 20min. Validation of this method consisted of confirmation of identity, selectivity, linearity, limit of detection (LOD), lowest limits of quantification (LLOQ), accuracy, precision, extraction recovery and matrix effect. The regression coefficients (r(2)) for the calibration curves (LLOQ - 100ng/mL) in the study were ≥0.99. The LODs for 65 validated compounds were better than 5ng/ml except for 4 compounds. The relative standard deviation (RSD), which was used to estimate repeatability at three concentrations, was always less than 15%. The recovery of extraction and matrix effects were above 50 and 70%, respectively. Mass accuracy was always better than 2ppm, corresponding to a maximum mass error of 0.8 millimass units (mmu). The accurate masses of characteristic fragments were obtained by collisional experiments for a more reliable identification of the analytes. Automated data analysis and reporting were performed using ToxID software with an exact mass database. This procedure was then successfully applied to analyse drugs of abuse in a real urine sample from subject who was assumed to be drug addict. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.
Vikhe, P S; Thool, V R
2016-04-01
Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.
Mammography status using patient self-reports and computerized radiology database.
Thompson, B; Taylor, V; Goldberg, H; Mullen, M
1999-10-01
This study sought to compare self-reported mammography use of low-income women utilizing an inner-city public hospital with a computerized hospital database for tracking mammography use. A survey of all age-eligible women using the hospital's internal medicine clinic was done; responses were matched with the radiology database. We examined concordance among the two data sources. Concordance between self-report and the database was high (82%) when using "ever had a mammogram at the hospital," but low (58%) when comparing self-reported last mammogram with the information contained in the database. Disagreements existed between self-reports and the database. Because we sought to ensure that women would know exactly what a mammogram entailed by including a picture of a woman having a mammogram, it is possible that women's responses were accurate, leading to concerns that discrepancies might be present in the database. Physicians and staff must ensure that they understand the full history of a woman's experience with mammography before recommending for or against the procedure.
Zero-Point Calibration for AGN Black-Hole Mass Estimates
NASA Technical Reports Server (NTRS)
Peterson, B. M.; Onken, C. A.
2004-01-01
We discuss the measurement and associated uncertainties of AGN reverberation-based black-hole masses, since these provide the zero-point calibration for scaling relationships that allow black-hole mass estimates for quasars. We find that reverberation-based mass estimates appear to be accurate to within a factor of about 3.
Fuel conditioning facility zone-to-zone transfer administrative controls.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pope, C. L.
2000-06-21
The administrative controls associated with transferring containers from one criticality hazard control zone to another in the Argonne National Laboratory (ANL) Fuel Conditioning Facility (FCF) are described. FCF, located at the ANL-West site near Idaho Falls, Idaho, is used to remotely process spent sodium bonded metallic fuel for disposition. The process involves nearly forty widely varying material forms and types, over fifty specific use container types, and over thirty distinct zones where work activities occur. During 1999, over five thousand transfers from one zone to another were conducted. Limits are placed on mass, material form and type, and container typesmore » for each zone. Ml material and containers are tracked using the Mass Tracking System (MTG). The MTG uses an Oracle database and numerous applications to manage the database. The database stores information specific to the process, including material composition and mass, container identification number and mass, transfer history, and the operators involved in each transfer. The process is controlled using written procedures which specify the zone, containers, and material involved in a task. Transferring a container from one zone to another is called a zone-to-zone transfer (ZZT). ZZTs consist of four distinct phases, select, request, identify, and completion.« less
Room temperature linelists for CO2 asymmetric isotopologues with ab initio computed intensities
NASA Astrophysics Data System (ADS)
Zak, Emil J.; Tennyson, Jonathan; Polyansky, Oleg L.; Lodi, Lorenzo; Zobov, Nikolay F.; Tashkun, Sergei A.; Perevalov, Valery I.
2017-12-01
The present paper reports room temperature line lists for six asymmetric isotopologues of carbon dioxide: 16O12C18O (628), 16O12C17O (627), 16O13C18O (638),16O13C17O (637), 17O12C18O (728) and 17O13C18O (738), covering the range 0-8000 cm-1. Variational rotation-vibration wavefunctions and energy levels are computed using the DVR3D software suite and a high quality semi-empirical potential energy surface (PES), followed by computation of intensities using an ab initio dipole moment surface (DMS). A theoretical procedure for quantifying sensitivity of line intensities to minor distortions of the PES/DMS renders our theoretical model as critically evaluated. Several recent high quality measurements and theoretical approaches are discussed to provide a benchmark of our results against the most accurate available data. Indeed, the thesis of transferability of accuracy among different isotopologues with the use of mass-independent PES is supported by several examples. Thereby, we conclude that the majority of line intensities for strong bands are predicted with sub-percent accuracy. Accurate line positions are generated using an effective Hamiltonian, constructed from the latest experiments. This study completes the list of relevant isotopologues of carbon dioxide; these line lists are available to remote sensing studies and inclusion in databases.
2000-07-16
Specifically, the management of the acute situation will set the tone for societal responses. The accurate portrayal of ongoing efforts and successful...their comments and actions. Specifically, the management of the acute situation will set the tone for societal responses. The accurate portrayal of...casualties. In the acute phase, anxiolytics may help acutely anxious individuals who do not respond to reassurance and education. In the chronic phase
Branda, John A; Rychert, Jenna; Burnham, Carey-Ann D; Bythrow, Maureen; Garner, Omai B; Ginocchio, Christine C; Jennemann, Rebecca; Lewinski, Michael A; Manji, Ryhana; Mochon, A Brian; Procop, Gary W; Richter, Sandra S; Sercia, Linda F; Westblade, Lars F; Ferraro, Mary Jane
2014-02-01
The VITEK MS v2.0 MALDI-TOF mass spectrometry system's performance in identifying fastidious gram-negative bacteria was evaluated in a multicenter study. Compared with the reference method (DNA sequencing), the VITEK MS system provided an accurate, species-level identification for 96% of 226 isolates; an additional 1% were accurately identified to the genus level. © 2013.
Prediction of the B{c}{*} mass in full lattice QCD.
Gregory, E B; Davies, C T H; Follana, E; Gamiz, E; Kendall, I D; Lepage, G P; Na, H; Shigemitsu, J; Wong, K Y
2010-01-15
By using the highly improved staggered quark formalism to handle charm, strange, and light valence quarks in full lattice QCD, and NRQCD to handle bottom valence quarks, we are able to determine accurately ratios of the B meson vector-pseudoscalar mass splittings, in particular, [m(B{c}{*})-m(B{c})]/[m(B{s}{*})-m(B{s})]. We find this ratio to be 1.15(15), showing the "light" quark mass dependence of this splitting to be very small. Hence we predict m(B{c}{*})=6.330(7)(2)(6) GeV, where the first two errors are from the lattice calculation and the third from existing experiment. This is the most accurate prediction of a gold-plated hadron mass from lattice QCD to date.
Sabareesh, Varatharajan; Singh, Gurpreet
2013-04-01
Mass Spectrometry based Lipid(ome) Analyzer and Molecular Platform (MS-LAMP) is a new software capable of aiding in interpreting electrospray ionization (ESI) and/or matrix-assisted laser desorption/ionization (MALDI) mass spectrometric data of lipids. The graphical user interface (GUI) of this standalone programme is built using Perl::Tk. Two databases have been developed and constituted within MS-LAMP, on the basis of Mycobacterium tuberculosis (M. tb) lipid database (www.mrl.colostate.edu) and that of Lipid Metabolites and Pathways Strategy Consortium (LIPID MAPS; www.lipidmaps.org). Different types of queries entered through GUI would interrogate with a chosen database. The queries can be molecular mass(es) or mass-to-charge (m/z) value(s) and molecular formula. LIPID MAPS identifier also can be used to search but not for M. tb lipids. Multiple choices have been provided to select diverse ion types and lipids. Satisfying to input parameters, a glimpse of various lipid categories and their population distribution can be viewed in the output. Additionally, molecular structures of lipids in the output can be seen using ChemSketch (www.acdlabs.com), which has been linked to the programme. Furthermore, a version of MS-LAMP for use in Linux operating system is separately available, wherein PyMOL can be used to view molecular structures that result as output from General Lipidome MS-LAMP. The utility of this software is demonstrated using ESI mass spectrometric data of lipid extracts of M. tb grown under two different pH (5.5 and 7.0) conditions. Copyright © 2013 John Wiley & Sons, Ltd.
de Vent, Nathalie R.; Agelink van Rentergem, Joost A.; Schmand, Ben A.; Murre, Jaap M. J.; Huizenga, Hilde M.
2016-01-01
In the Advanced Neuropsychological Diagnostics Infrastructure (ANDI), datasets of several research groups are combined into a single database, containing scores on neuropsychological tests from healthy participants. For most popular neuropsychological tests the quantity, and range of these data surpasses that of traditional normative data, thereby enabling more accurate neuropsychological assessment. Because of the unique structure of the database, it facilitates normative comparison methods that were not feasible before, in particular those in which entire profiles of scores are evaluated. In this article, we describe the steps that were necessary to combine the separate datasets into a single database. These steps involve matching variables from multiple datasets, removing outlying values, determining the influence of demographic variables, and finding appropriate transformations to normality. Also, a brief description of the current contents of the ANDI database is given. PMID:27812340
de Vent, Nathalie R; Agelink van Rentergem, Joost A; Schmand, Ben A; Murre, Jaap M J; Huizenga, Hilde M
2016-01-01
In the Advanced Neuropsychological Diagnostics Infrastructure (ANDI), datasets of several research groups are combined into a single database, containing scores on neuropsychological tests from healthy participants. For most popular neuropsychological tests the quantity, and range of these data surpasses that of traditional normative data, thereby enabling more accurate neuropsychological assessment. Because of the unique structure of the database, it facilitates normative comparison methods that were not feasible before, in particular those in which entire profiles of scores are evaluated. In this article, we describe the steps that were necessary to combine the separate datasets into a single database. These steps involve matching variables from multiple datasets, removing outlying values, determining the influence of demographic variables, and finding appropriate transformations to normality. Also, a brief description of the current contents of the ANDI database is given.
Organizing a breast cancer database: data management.
Yi, Min; Hunt, Kelly K
2016-06-01
Developing and organizing a breast cancer database can provide data and serve as valuable research tools for those interested in the etiology, diagnosis, and treatment of cancer. Depending on the research setting, the quality of the data can be a major issue. Assuring that the data collection process does not contribute inaccuracies can help to assure the overall quality of subsequent analyses. Data management is work that involves the planning, development, implementation, and administration of systems for the acquisition, storage, and retrieval of data while protecting it by implementing high security levels. A properly designed database provides you with access to up-to-date, accurate information. Database design is an important component of application design. If you take the time to design your databases properly, you'll be rewarded with a solid application foundation on which you can build the rest of your application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghezzi, Luan; Johnson, John Asher, E-mail: lghezzi@cfa.harvard.edu
2015-10-20
Characterizing the physical properties of exoplanets and understanding their formation and orbital evolution requires precise and accurate knowledge of their host stars. Accurately measuring stellar masses is particularly important because they likely influence planet occurrence and the architectures of planetary systems. Single main-sequence stars typically have masses estimated from evolutionary tracks, which generally provide accurate results due to their extensive empirical calibration. However, the validity of this method for subgiants and giants has been called into question by recent studies, with suggestions that the masses of these evolved stars could have been overestimated. We investigate these concerns using a samplemore » of 59 benchmark evolved stars with model-independent masses (from binary systems or asteroseismology) obtained from the literature. We find very good agreement between these benchmark masses and the ones estimated using evolutionary tracks. The average fractional difference in the mass interval ∼0.7–4.5 M{sub ⊙} is consistent with zero (−1.30 ± 2.42%), with no significant trends in the residuals relative to the input parameters. A good agreement between model-dependent and -independent radii (−4.81 ± 1.32%) and surface gravities (0.71 ± 0.51%) is also found. The consistency between independently determined ages for members of binary systems adds further support for the accuracy of the method employed to derive the stellar masses. Taken together, our results indicate that determination of masses of evolved stars using grids of evolutionary tracks is not significantly affected by systematic errors, and is thus valid for estimating the masses of isolated stars beyond the main sequence.« less
Wang, Penghao; Wilson, Susan R
2013-01-01
Mass spectrometry-based protein identification is a very challenging task. The main identification approaches include de novo sequencing and database searching. Both approaches have shortcomings, so an integrative approach has been developed. The integrative approach firstly infers partial peptide sequences, known as tags, directly from tandem spectra through de novo sequencing, and then puts these sequences into a database search to see if a close peptide match can be found. However the current implementation of this integrative approach has several limitations. Firstly, simplistic de novo sequencing is applied and only very short sequence tags are used. Secondly, most integrative methods apply an algorithm similar to BLAST to search for exact sequence matches and do not accommodate sequence errors well. Thirdly, by applying these methods the integrated de novo sequencing makes a limited contribution to the scoring model which is still largely based on database searching. We have developed a new integrative protein identification method which can integrate de novo sequencing more efficiently into database searching. Evaluated on large real datasets, our method outperforms popular identification methods.
Prakash, Peralam Yegneswaran; Irinyi, Laszlo; Halliday, Catriona; Chen, Sharon; Robert, Vincent
2017-01-01
ABSTRACT The increase in public online databases dedicated to fungal identification is noteworthy. This can be attributed to improved access to molecular approaches to characterize fungi, as well as to delineate species within specific fungal groups in the last 2 decades, leading to an ever-increasing complexity of taxonomic assortments and nomenclatural reassignments. Thus, well-curated fungal databases with substantial accurate sequence data play a pivotal role for further research and diagnostics in the field of mycology. This minireview aims to provide an overview of currently available online databases for the taxonomy and identification of human and animal-pathogenic fungi and calls for the establishment of a cloud-based dynamic data network platform. PMID:28179406
75 FR 70926 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
...; Title of Information Collection: Medicare/Medicaid Psychiatric Hospital Survey Data; Use: The CMS-724... evaluation and in maintaining an accurate database on providers participating in the psychiatric hospital...
SPECIATE Version 4.5 Database Development Documentation
This product updated SPECIATE 4.4 with new emission profiles to address high priority Agency data gaps and to included new, more accurate emission profiles generated by research underway within and outside the Agency.
The Facility Registry System (FRS) is a centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. FRS creates high-quality, accurate, and authoritative facility identification records through rigorous...
New results in gravity dependent two-phase flow regime mapping
NASA Astrophysics Data System (ADS)
Kurwitz, Cable; Best, Frederick
2002-01-01
Accurate prediction of thermal-hydraulic parameters, such as the spatial gas/liquid orientation or flow regime, is required for implementation of two-phase systems. Although many flow regime transition models exist, accurate determination of both annular and slug regime boundaries is not well defined especially at lower flow rates. Furthermore, models typically indicate the regime as a sharp transition where data may indicate a transition space. Texas A&M has flown in excess of 35 flights aboard the NASA KC-135 aircraft with a unique two-phase package. These flights have produced a significant database of gravity dependent two-phase data including visual observations for flow regime identification. Two-phase flow tests conducted during recent zero-g flights have added to the flow regime database and are shown in this paper with comparisons to selected transition models. .
Tatem, Andrew J; Guerra, Carlos A; Kabaria, Caroline W; Noor, Abdisalan M; Hay, Simon I
2008-10-27
The efficient allocation of financial resources for malaria control and the optimal distribution of appropriate interventions require accurate information on the geographic distribution of malaria risk and of the human populations it affects. Low population densities in rural areas and high population densities in urban areas can influence malaria transmission substantially. Here, the Malaria Atlas Project (MAP) global database of Plasmodium falciparum parasite rate (PfPR) surveys, medical intelligence and contemporary population surfaces are utilized to explore these relationships and other issues involved in combining malaria risk maps with those of human population distribution in order to define populations at risk more accurately. First, an existing population surface was examined to determine if it was sufficiently detailed to be used reliably as a mask to identify areas of very low and very high population density as malaria free regions. Second, the potential of international travel and health guidelines (ITHGs) for identifying malaria free cities was examined. Third, the differences in PfPR values between surveys conducted in author-defined rural and urban areas were examined. Fourth, the ability of various global urban extent maps to reliably discriminate these author-based classifications of urban and rural in the PfPR database was investigated. Finally, the urban map that most accurately replicated the author-based classifications was analysed to examine the effects of urban classifications on PfPR values across the entire MAP database. Masks of zero population density excluded many non-zero PfPR surveys, indicating that the population surface was not detailed enough to define areas of zero transmission resulting from low population densities. In contrast, the ITHGs enabled the identification and mapping of 53 malaria free urban areas within endemic countries. Comparison of PfPR survey results showed significant differences between author-defined 'urban' and 'rural' designations in Africa, but not for the remainder of the malaria endemic world. The Global Rural Urban Mapping Project (GRUMP) urban extent mask proved most accurate for mapping these author-defined rural and urban locations, and further sub-divisions of urban extents into urban and peri-urban classes enabled the effects of high population densities on malaria transmission to be mapped and quantified. The availability of detailed, contemporary census and urban extent data for the construction of coherent and accurate global spatial population databases is often poor. These known sources of uncertainty in population surfaces and urban maps have the potential to be incorporated into future malaria burden estimates. Currently, insufficient spatial information exists globally to identify areas accurately where population density is low enough to impact upon transmission. Medical intelligence does however exist to reliably identify malaria free cities. Moreover, in Africa, urban areas that have a significant effect on malaria transmission can be mapped.
Lee, Howard; Chapiro, Julius; Schernthaner, Rüdiger; Duran, Rafael; Wang, Zhijun; Gorodetski, Boris; Geschwind, Jean-François; Lin, MingDe
2015-04-01
The objective of this study was to demonstrate that an intra-arterial liver therapy clinical research database system is a more workflow efficient and robust tool for clinical research than a spreadsheet storage system. The database system could be used to generate clinical research study populations easily with custom search and retrieval criteria. A questionnaire was designed and distributed to 21 board-certified radiologists to assess current data storage problems and clinician reception to a database management system. Based on the questionnaire findings, a customized database and user interface system were created to perform automatic calculations of clinical scores including staging systems such as the Child-Pugh and Barcelona Clinic Liver Cancer, and facilitates data input and output. Questionnaire participants were favorable to a database system. The interface retrieved study-relevant data accurately and effectively. The database effectively produced easy-to-read study-specific patient populations with custom-defined inclusion/exclusion criteria. The database management system is workflow efficient and robust in retrieving, storing, and analyzing data. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Design and Establishment of Quality Model of Fundamental Geographic Information Database
NASA Astrophysics Data System (ADS)
Ma, W.; Zhang, J.; Zhao, Y.; Zhang, P.; Dang, Y.; Zhao, T.
2018-04-01
In order to make the quality evaluation for the Fundamental Geographic Information Databases(FGIDB) more comprehensive, objective and accurate, this paper studies and establishes a quality model of FGIDB, which formed by the standardization of database construction and quality control, the conformity of data set quality and the functionality of database management system, and also designs the overall principles, contents and methods of the quality evaluation for FGIDB, providing the basis and reference for carry out quality control and quality evaluation for FGIDB. This paper designs the quality elements, evaluation items and properties of the Fundamental Geographic Information Database gradually based on the quality model framework. Connected organically, these quality elements and evaluation items constitute the quality model of the Fundamental Geographic Information Database. This model is the foundation for the quality demand stipulation and quality evaluation of the Fundamental Geographic Information Database, and is of great significance on the quality assurance in the design and development stage, the demand formulation in the testing evaluation stage, and the standard system construction for quality evaluation technology of the Fundamental Geographic Information Database.
Geographic Information System Data Analysis
NASA Technical Reports Server (NTRS)
Billings, Chad; Casad, Christopher; Floriano, Luis G.; Hill, Tracie; Johnson, Rashida K.; Locklear, J. Mark; Penn, Stephen; Rhoulac, Tori; Shay, Adam H.; Taylor, Antone;
1995-01-01
Data was collected in order to further NASA Langley Research Center's Geographic Information System(GIS). Information on LaRC's communication, electrical, and facility configurations was collected. Existing data was corrected through verification, resulting in more accurate databases. In addition, Global Positioning System(GPS) points were used in order to accurately impose buildings on digitized images. Overall, this project will help the Imaging and CADD Technology Team (ICTT) prove GIS to be a valuable resource for LaRC.
Sleiman, Sue; Halliday, Catriona L.; Chapman, Belinda; Brown, Mitchell; Nitschke, Joanne; Lau, Anna F.
2016-01-01
We developed an Australian database for the identification of Aspergillus, Scedosporium, and Fusarium species (n = 28) by matrix-assisted laser desorption ionization−time of flight mass spectrometry (MALDI-TOF MS). In a challenge against 117 isolates, species identification significantly improved when the in-house-built database was combined with the Bruker Filamentous Fungi Library compared with that for the Bruker library alone (Aspergillus, 93% versus 69%; Fusarium, 84% versus 42%; and Scedosporium, 94% versus 18%, respectively). PMID:27252460
Ochiai, Nobuo; Mitsui, Kazuhisa; Sasamoto, Kikuo; Yoshimura, Yuta; David, Frank; Sandra, Pat
2014-09-05
A method is developed for identification of sulfur compounds in tobacco smoke extract. The method is based on large volume injection (LVI) of 10μL of tobacco smoke extract followed by selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography (GC) coupled to a hybrid quadrupole time-of-flight mass spectrometer (Q-TOF-MS) using electron ionization (EI) and positive chemical ionization (PCI), with parallel sulfur chemiluminescence detection (SCD). In order to identify each individual sulfur compound, sequential heart-cuts of 28 sulfur fractions from (1)D GC to (2)D GC were performed with the three MS detection modes (SCD/EI-TOF-MS, SCD/PCI-TOF-MS, and SCD/PCI-Q-TOF-MS). Thirty sulfur compounds were positively identified by MS library search, linear retention indices (LRI), molecular mass determination using PCI accurate mass spectra, formula calculation using EI and PCI accurate mass spectra, and structure elucidation using collision activated dissociation (CAD) of the protonated molecule. Additionally, 11 molecular formulas were obtained for unknown sulfur compounds. The determined values of the identified and unknown sulfur compounds were in the range of 10-740ngmg total particulate matter (TPM) (RSD: 1.2-12%, n=3). Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Venkatesh, Sudhakar K.; Chandan, Vishal; Roberts, Lewis R.
2013-01-01
Liver masses present a relatively common clinical dilemma, particularly with the increasing use of various imaging modalities in the diagnosis of abdominal and other symptoms. The accurate and reliable determination of the nature of the liver mass is critical, not only to reassure individuals with benign lesions but also, and perhaps more importantly, to ensure that malignant lesions are diagnosed correctly. This avoids the devastating consequences of missed diagnosis and the delayed treatment of malignancy or the unnecessary treatment of benign lesions With appropriate interpretation of the clinical history and physical examination, and the judicious use of laboratory and imaging studies, the majority of liver masses can be characterized noninvasively. Accurate characterization of liver masses by cross-sectional imaging is particularly dependent on an understanding of the unique phasic vascular perfusion of the liver and the characteristic behaviors of different lesions during multiphasic contrast imaging. When non-invasive characterization is indeterminate, a liver biopsy may be necessary for definitive diagnosis. Standard histologic examination is usually complemented by immunohistochemical analysis of protein biomarkers. Accurate diagnosis allows the appropriate selection of optimal management, which is frequently reassurance or intermittent follow up for benign masses. For malignant lesions or those at risk of malignant transformation, management depends on the tumor staging, the functional status of the uninvolved liver and technical surgical considerations. Unresectable metastatic masses require oncologic consultation and therapy. The efficient characterization and management of liver masses therefore requires a multidisciplinary collaboration between the gastroenterologist/hepatologist, radiologist, pathologist, hepatobiliary or transplant surgeon, and medical oncologist. PMID:24055987
After a dispersive event, rapid determination of elemental compositions of ions in mass spectra is essential for tentatively identifying compounds. A Direct Analysis in Real Time (DART)® ion source interfaced to a JEOL AccuTOF® mass spectrometer provided exact masses accurate to ...
Accurate Mass Determination of Organotrifluoroborates
Petrillo, Daniel E.; Kohli, Rakesh K.; Molander, Gary A.
2007-01-01
Exact mass measurements were obtained for a variety of potassium- and tetra-n-butylammonium organotrifluoroborates using commercially available organic sulfate salts as internal reference standards. Accuracies were determined within 5 ppm using a sector ESI mass spectrometer operating in the negative ionization mode. PMID:17112738
Zhang, Lin; Vranckx, Katleen; Janssens, Koen; Sandrin, Todd R.
2015-01-01
MALDI-TOF mass spectrometry has been shown to be a rapid and reliable tool for identification of bacteria at the genus and species, and in some cases, strain levels. Commercially available and open source software tools have been developed to facilitate identification; however, no universal/standardized data analysis pipeline has been described in the literature. Here, we provide a comprehensive and detailed demonstration of bacterial identification procedures using a MALDI-TOF mass spectrometer. Mass spectra were collected from 15 diverse bacteria isolated from Kartchner Caverns, AZ, USA, and identified by 16S rDNA sequencing. Databases were constructed in BioNumerics 7.1. Follow-up analyses of mass spectra were performed, including cluster analyses, peak matching, and statistical analyses. Identification was performed using blind-coded samples randomly selected from these 15 bacteria. Two identification methods are presented: similarity coefficient-based and biomarker-based methods. Results show that both identification methods can identify the bacteria to the species level. PMID:25590854
Zhang, Lin; Vranckx, Katleen; Janssens, Koen; Sandrin, Todd R
2015-01-02
MALDI-TOF mass spectrometry has been shown to be a rapid and reliable tool for identification of bacteria at the genus and species, and in some cases, strain levels. Commercially available and open source software tools have been developed to facilitate identification; however, no universal/standardized data analysis pipeline has been described in the literature. Here, we provide a comprehensive and detailed demonstration of bacterial identification procedures using a MALDI-TOF mass spectrometer. Mass spectra were collected from 15 diverse bacteria isolated from Kartchner Caverns, AZ, USA, and identified by 16S rDNA sequencing. Databases were constructed in BioNumerics 7.1. Follow-up analyses of mass spectra were performed, including cluster analyses, peak matching, and statistical analyses. Identification was performed using blind-coded samples randomly selected from these 15 bacteria. Two identification methods are presented: similarity coefficient-based and biomarker-based methods. Results show that both identification methods can identify the bacteria to the species level.
An Aerodynamic Analysis of a Spinning Missile with Dithering Canards
NASA Technical Reports Server (NTRS)
Meakin, Robert L.; Nygaard, Tor A.
2003-01-01
A generic spinning missile with dithering canards is used to demonstrate the utility of an overset structured grid approach for simulating the aerodynamics of rolling airframe missile systems. The approach is used to generate a modest aerodynamic database for the generic missile. The database is populated with solutions to the Euler and Navier-Stokes equations. It is used to evaluate grid resolution requirements for accurate prediction of instantaneous missile loads and the relative aerodynamic significance of angle-of-attack, canard pitching sequence, viscous effects, and roll-rate effects. A novel analytical method for inter- and extrapolation of database results is also given.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Board's information technology infrastructure, including computer systems, networks, databases, and... with information regarding the Safety Board's activities, programs and objectives; supplies the public, the transportation industry and the news media with current, accurate information concerning the work...
Hinke, Jefferson T.; Perryman, Wayne L.; Goebel, Michael E.; LeRoi, Donald J.
2017-01-01
Measurements of body size and mass are fundamental to pinniped population management and research. Manual measurements tend to be accurate but are invasive and logistically challenging to obtain. Ground-based photogrammetric techniques are less invasive, but inherent limitations make them impractical for many field applications. The recent proliferation of unmanned aerial systems (UAS) in wildlife monitoring has provided a promising new platform for the photogrammetry of free-ranging pinnipeds. Leopard seals (Hydrurga leptonyx) are an apex predator in coastal Antarctica whose body condition could be a valuable indicator of ecosystem health. We aerially surveyed leopard seals of known body size and mass to test the precision and accuracy of photogrammetry from a small UAS. Flights were conducted in January and February of 2013 and 2014 and 50 photogrammetric samples were obtained from 15 unrestrained seals. UAS-derived measurements of standard length were accurate to within 2.01 ± 1.06%, and paired comparisons with ground measurements were statistically indistinguishable. An allometric linear mixed effects model predicted leopard seal mass within 19.40 kg (4.4% error for a 440 kg seal). Photogrammetric measurements from a single, vertical image obtained using UAS provide a noninvasive approach for estimating the mass and body condition of pinnipeds that may be widely applicable. PMID:29186134
Krause, Douglas J; Hinke, Jefferson T; Perryman, Wayne L; Goebel, Michael E; LeRoi, Donald J
2017-01-01
Measurements of body size and mass are fundamental to pinniped population management and research. Manual measurements tend to be accurate but are invasive and logistically challenging to obtain. Ground-based photogrammetric techniques are less invasive, but inherent limitations make them impractical for many field applications. The recent proliferation of unmanned aerial systems (UAS) in wildlife monitoring has provided a promising new platform for the photogrammetry of free-ranging pinnipeds. Leopard seals (Hydrurga leptonyx) are an apex predator in coastal Antarctica whose body condition could be a valuable indicator of ecosystem health. We aerially surveyed leopard seals of known body size and mass to test the precision and accuracy of photogrammetry from a small UAS. Flights were conducted in January and February of 2013 and 2014 and 50 photogrammetric samples were obtained from 15 unrestrained seals. UAS-derived measurements of standard length were accurate to within 2.01 ± 1.06%, and paired comparisons with ground measurements were statistically indistinguishable. An allometric linear mixed effects model predicted leopard seal mass within 19.40 kg (4.4% error for a 440 kg seal). Photogrammetric measurements from a single, vertical image obtained using UAS provide a noninvasive approach for estimating the mass and body condition of pinnipeds that may be widely applicable.
This SOP described the method used to automatically parse analytical data generated from gas chromatography/mass spectrometry (GC/MS) analyses into CTEPP summary spreadsheets and electronically import the summary spreadsheets into the CTEPP study database.
USDA-ARS?s Scientific Manuscript database
Vitamin D has been identified as a nutrient of top public health concern because of its role in bone health and its link to other diseases and conditions. However, there are many knowledge gaps in the study of vitamin D, including lack of updated analytical data and accurate intake estimates from na...
Monitoring Earth's reservoir and lake dynamics from space
NASA Astrophysics Data System (ADS)
Donchyts, G.; Eilander, D.; Schellekens, J.; Winsemius, H.; Gorelick, N.; Erickson, T.; Van De Giesen, N.
2016-12-01
Reservoirs and lakes constitute about 90% of the Earth's fresh surface water. They play a major role in the water cycle and are critical for the ever increasing demands of the world's growing population. Water from reservoirs is used for agricultural, industrial, domestic, and other purposes. Current digital databases of lakes and reservoirs are scarce, mainly providing only descriptive and static properties of the reservoirs. The Global Reservoir and Dam (GRanD) database contains almost 7000 entries while OpenStreetMap counts more than 500 000 entries tagged as a reservoir. In the last decade several research efforts already focused on accurate estimates of surface water dynamics, mainly using satellite altimetry, However, currently they are limited only to less than 1000 (mostly large) water bodies. Our approach is based on three main components. Firstly, a novel method, allowing automated and accurate estimation of surface area from (partially) cloud-free optical multispectral or radar satellite imagery. The algorithm uses satellite imagery measured by Landsat, Sentinel and MODIS missions. Secondly, a database to store reservoir static and dynamic parameters. Thirdly, a web-based tool, built on top of Google Earth Engine infrastructure. The tool allows estimation of surface area for lakes and reservoirs at planetary-scale at high spatial and temporal resolution. A prototype version of the method, database, and tool will be presented as well as validation using in-situ measurements.
Strong, Vivian E.; Selby, Luke V.; Sovel, Mindy; Disa, Joseph J.; Hoskins, William; DeMatteo, Ronald; Scardino, Peter; Jaques, David P.
2015-01-01
Background Studying surgical secondary events is an evolving effort with no current established system for database design, standard reporting, or definitions. Using the Clavien-Dindo classification as a guide, in 2001 we developed a Surgical Secondary Events database based on grade of event and required intervention to begin prospectively recording and analyzing all surgical secondary events (SSE). Study Design Events are prospectively entered into the database by attending surgeons, house staff, and research staff. In 2008 we performed a blinded external audit of 1,498 operations that were randomly selected to examine the quality and reliability of the data. Results 1,498 of 4,284 operations during the 3rd quarter of 2008 were audited. 79% (N=1,180) of the operations did not have a secondary event while 21% (N=318) of operations had an identified event. 91% (1,365) of operations were correctly entered into the SSE database. 97% (129/133) of missed secondary events were Grades I and II. Three Grade III (2%) and one Grade IV (1%) secondary event were missed. There were no missed Grade 5 secondary events. Conclusion Grade III – IV events are more accurately collected than Grade I – II events. Robust and accurate secondary events data can be collected by clinicians and research staff and these data can safely be used for quality improvement projects and research. PMID:25319579
Strong, Vivian E; Selby, Luke V; Sovel, Mindy; Disa, Joseph J; Hoskins, William; Dematteo, Ronald; Scardino, Peter; Jaques, David P
2015-04-01
Studying surgical secondary events is an evolving effort with no current established system for database design, standard reporting, or definitions. Using the Clavien-Dindo classification as a guide, in 2001 we developed a Surgical Secondary Events database based on grade of event and required intervention to begin prospectively recording and analyzing all surgical secondary events (SSE). Events are prospectively entered into the database by attending surgeons, house staff, and research staff. In 2008 we performed a blinded external audit of 1,498 operations that were randomly selected to examine the quality and reliability of the data. Of 4,284 operations, 1,498 were audited during the third quarter of 2008. Of these operations, 79 % (N = 1,180) did not have a secondary event while 21 % (N = 318) had an identified event; 91 % of operations (1,365) were correctly entered into the SSE database. Also 97 % (129 of 133) of missed secondary events were grades I and II. There were 3 grade III (2 %) and 1 grade IV (1 %) secondary event that were missed. There were no missed grade 5 secondary events. Grade III-IV events are more accurately collected than grade I-II events. Robust and accurate secondary events data can be collected by clinicians and research staff, and these data can safely be used for quality improvement projects and research.
Dereplication of peptidic natural products through database search of mass spectra
Mohimani, Hosein; Gurevich, Alexey; Mikheenko, Alla; Garg, Neha; Nothias, Louis-Felix; Ninomiya, Akihiro; Takada, Kentaro; Dorrestein, Pieter C.; Pevzner, Pavel A.
2016-01-01
Peptidic Natural Products (PNPs) are widely used compounds that include many antibiotics and a variety of other bioactive peptides. While recent breakthroughs in PNP discovery raised the challenge of developing new algorithms for their analysis, identification of PNPs via database search of tandem mass spectra remains an open problem. To address this problem, natural product researchers utilize dereplication strategies that identify known PNPs and lead to the discovery of new ones even in cases when the reference spectra are not present in existing spectral libraries. DEREPLICATOR is a new dereplication algorithm that enabled high-throughput PNP identification and that is compatible with large-scale mass spectrometry-based screening platforms for natural product discovery. After searching nearly one hundred million tandem mass spectra in the Global Natural Products Social (GNPS) molecular networking infrastructure, DEREPLICATOR identified an order of magnitude more PNPs (and their new variants) than any previous dereplication efforts. PMID:27820803
A knowledge-based T2-statistic to perform pathway analysis for quantitative proteomic data
Chen, Yi-Hau
2017-01-01
Approaches to identify significant pathways from high-throughput quantitative data have been developed in recent years. Still, the analysis of proteomic data stays difficult because of limited sample size. This limitation also leads to the practice of using a competitive null as common approach; which fundamentally implies genes or proteins as independent units. The independent assumption ignores the associations among biomolecules with similar functions or cellular localization, as well as the interactions among them manifested as changes in expression ratios. Consequently, these methods often underestimate the associations among biomolecules and cause false positives in practice. Some studies incorporate the sample covariance matrix into the calculation to address this issue. However, sample covariance may not be a precise estimation if the sample size is very limited, which is usually the case for the data produced by mass spectrometry. In this study, we introduce a multivariate test under a self-contained null to perform pathway analysis for quantitative proteomic data. The covariance matrix used in the test statistic is constructed by the confidence scores retrieved from the STRING database or the HitPredict database. We also design an integrating procedure to retain pathways of sufficient evidence as a pathway group. The performance of the proposed T2-statistic is demonstrated using five published experimental datasets: the T-cell activation, the cAMP/PKA signaling, the myoblast differentiation, and the effect of dasatinib on the BCR-ABL pathway are proteomic datasets produced by mass spectrometry; and the protective effect of myocilin via the MAPK signaling pathway is a gene expression dataset of limited sample size. Compared with other popular statistics, the proposed T2-statistic yields more accurate descriptions in agreement with the discussion of the original publication. We implemented the T2-statistic into an R package T2GA, which is available at https://github.com/roqe/T2GA. PMID:28622336
A knowledge-based T2-statistic to perform pathway analysis for quantitative proteomic data.
Lai, En-Yu; Chen, Yi-Hau; Wu, Kun-Pin
2017-06-01
Approaches to identify significant pathways from high-throughput quantitative data have been developed in recent years. Still, the analysis of proteomic data stays difficult because of limited sample size. This limitation also leads to the practice of using a competitive null as common approach; which fundamentally implies genes or proteins as independent units. The independent assumption ignores the associations among biomolecules with similar functions or cellular localization, as well as the interactions among them manifested as changes in expression ratios. Consequently, these methods often underestimate the associations among biomolecules and cause false positives in practice. Some studies incorporate the sample covariance matrix into the calculation to address this issue. However, sample covariance may not be a precise estimation if the sample size is very limited, which is usually the case for the data produced by mass spectrometry. In this study, we introduce a multivariate test under a self-contained null to perform pathway analysis for quantitative proteomic data. The covariance matrix used in the test statistic is constructed by the confidence scores retrieved from the STRING database or the HitPredict database. We also design an integrating procedure to retain pathways of sufficient evidence as a pathway group. The performance of the proposed T2-statistic is demonstrated using five published experimental datasets: the T-cell activation, the cAMP/PKA signaling, the myoblast differentiation, and the effect of dasatinib on the BCR-ABL pathway are proteomic datasets produced by mass spectrometry; and the protective effect of myocilin via the MAPK signaling pathway is a gene expression dataset of limited sample size. Compared with other popular statistics, the proposed T2-statistic yields more accurate descriptions in agreement with the discussion of the original publication. We implemented the T2-statistic into an R package T2GA, which is available at https://github.com/roqe/T2GA.
Creating databases for biological information: an introduction.
Stein, Lincoln
2013-06-01
The essence of bioinformatics is dealing with large quantities of information. Whether it be sequencing data, microarray data files, mass spectrometric data (e.g., fingerprints), the catalog of strains arising from an insertional mutagenesis project, or even large numbers of PDF files, there inevitably comes a time when the information can simply no longer be managed with files and directories. This is where databases come into play. This unit briefly reviews the characteristics of several database management systems, including flat file, indexed file, relational databases, and NoSQL databases. It compares their strengths and weaknesses and offers some general guidelines for selecting an appropriate database management system. Copyright 2013 by JohnWiley & Sons, Inc.
Development of a Searchable Database of Cryoablation Simulations for Use in Treatment Planning.
Boas, F Edward; Srimathveeravalli, Govindarajan; Durack, Jeremy C; Kaye, Elena A; Erinjeri, Joseph P; Ziv, Etay; Maybody, Majid; Yarmohammadi, Hooman; Solomon, Stephen B
2017-05-01
To create and validate a planning tool for multiple-probe cryoablation, using simulations of ice ball size and shape for various ablation probe configurations, ablation times, and types of tissue ablated. Ice ball size and shape was simulated using the Pennes bioheat equation. Five thousand six hundred and seventy different cryoablation procedures were simulated, using 1-6 cryoablation probes and 1-2 cm spacing between probes. The resulting ice ball was measured along three perpendicular axes and recorded in a database. Simulated ice ball sizes were compared to gel experiments (26 measurements) and clinical cryoablation cases (42 measurements). The clinical cryoablation measurements were obtained from a HIPAA-compliant retrospective review of kidney and liver cryoablation procedures between January 2015 and February 2016. Finally, we created a web-based cryoablation planning tool, which uses the cryoablation simulation database to look up the probe spacing and ablation time that produces the desired ice ball shape and dimensions. Average absolute error between the simulated and experimentally measured ice balls was 1 mm in gel experiments and 4 mm in clinical cryoablation cases. The simulations accurately predicted the degree of synergy in multiple-probe ablations. The cryoablation simulation database covers a wide range of ice ball sizes and shapes up to 9.8 cm. Cryoablation simulations accurately predict the ice ball size in multiple-probe ablations. The cryoablation database can be used to plan ablation procedures: given the desired ice ball size and shape, it will find the number and type of probes, probe configuration and spacing, and ablation time required.
Nakamura, Sayaka; Sato, Hiroaki; Tanaka, Reiko; Kusuya, Yoko; Takahashi, Hiroki; Yaguchi, Takashi
2017-04-26
Accurate identification of Aspergillus species is a very important subject. Mass spectral fingerprinting using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is generally employed for the rapid identification of fungal isolates. However, the results are based on simple mass spectral pattern-matching, with no peak assignment and no taxonomic input. We propose here a ribosomal subunit protein (RSP) typing technique using MALDI-TOF MS for the identification and discrimination of Aspergillus species. The results are concluded to be phylogenetic in that they reflect the molecular evolution of housekeeping RSPs. The amino acid sequences of RSPs of genome-sequenced strains of Aspergillus species were first verified and compared to compile a reliable biomarker list for the identification of Aspergillus species. In this process, we revealed that many amino acid sequences of RSPs (about 10-60%, depending on strain) registered in the public protein databases needed to be corrected or newly added. The verified RSPs were allocated to RSP types based on their mass. Peak assignments of RSPs of each sample strain as observed by MALDI-TOF MS were then performed to set RSP type profiles, which were then further processed by means of cluster analysis. The resulting dendrogram based on RSP types showed a relatively good concordance with the tree based on β-tubulin gene sequences. RSP typing was able to further discriminate the strains belonging to Aspergillus section Fumigati. The RSP typing method could be applied to identify Aspergillus species, even for species within section Fumigati. The discrimination power of RSP typing appears to be comparable to conventional β-tubulin gene analysis. This method would therefore be suitable for species identification and discrimination at the strain to species level. Because RSP typing can characterize the strains within section Fumigati, this method has potential as a powerful and reliable tool in the field of clinical microbiology.
A profile of sphingolipids and related compounds tentatively identified in yak milk.
Qu, S; Barrett-Wilt, G; Fonseca, L M; Rankin, S A
2016-07-01
This work characterized a fraction of constituents in yak milk within the realm of approximately 1,000 to 3,000 Da using matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Eleven samples of yak milk powder from the Sichuan province of China were received by the Department of Food Science, University of Wisconsin-Madison, and stored at room temperature until analysis. Sample preparation involved delipidation and deproteinization of yak milk samples and cold ethanol precipitation. Subsequently, MALDI time-of-flight mass spectrometry was performed in positive ion, reflector mode (AB Sciex TOF/TOF 4800 MALDI; AB Sciex, Foster City, CA). The instrument was first calibrated with the manufacturer's 6-peptide mixture, and each spectrum was internally calibrated using the accurate mass of ACTH Fragment 18-39 standard peptide (protonated mass at m/z 2464.199) present in each sample. Laser power was adjusted for the calibration standards and for each sample so that the signal obtained for the most-abundant ion in each spectrum could be maximized, or kept below ~2×10(4) to preserve spectral quality. Structure and name based on mass were matched using the Metlin metabolite database (https://metlin.scripps.edu/index.php). Results of the current work for yak milk powder showed a large variety of sphingolipid structures with clusters around 1,200, 1,600, and 2,000 Da. The profiling matched several glycosphingolipids, such as gangliosides GA1, GD1a, GD1b, GD3, GM1, GM2, GM3, and GT2 and several other unique moieties, including deaminated neuraminic acid (KDN) oligosaccharides, and fucose containing gangliosides. Matrix preparation and MALDI time-of-flight parameters were important factors established in this work to allow high resolution profiling of complex sphingolipids in yak powder milk. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Nielen, Michel W F; Bovee, Toine F H; van Engelen, Marcel C; Rutgers, Paula; Hamers, Astrid R M; van Rhijn, J Hans A; Hoogenboom, L Ron A P
2006-01-15
New anabolic steroids show up occasionally in sports doping and in veterinary control. The discovery of these designer steroids is facilitated by findings of illicit preparations, thus allowing bioactivity testing, structure elucidation using NMR and mass spectrometry, and final incorporation in urine testing. However, as long as these preparations remain undiscovered, new designer steroids are not screened for in routine sports doping or veterinary control urine tests since the established GC/MS and LC/MS/MS methods are set up for the monitoring of a few selected ions or MS/MS transitions of known substances only. In this study, the feasibility of androgen bioactivity testing and mass spectrometric identification is being investigated for trace analysis of designer steroids in urine. Following enzymatic deconjugation and a generic solid-phase extraction, the samples are analyzed by gradient LC with effluent splitting toward two identical 96-well fraction collectors. One well plate is used for androgen bioactivity detection using a novel robust yeast reporter gene bioassay yielding a biogram featuring a 20-s time resolution. The bioactive wells direct the identification efforts to the corresponding well numbers in the duplicate plate. These are subjected to high-resolution LC using a short column packed with 1.7-microm C18 material and coupled with electrospray quadrupole time-of-flight mass spectrometry (LC/QTOFMS) with accurate mass measurement. Element compositions are calculated and used to interrogate electronic substance databases. The feasibility of this approach for doping control is demonstrated via the screening of human urine samples spiked with the designer anabolic steroid tetrahydrogestrinone. Application of the proposed methodology, complementary to the established targeted urine screening for known anabolics, will increase the chance of finding unknown emerging designer steroids, rather then being solely dependent on findings of the illicit preparations themselves.
NASA Astrophysics Data System (ADS)
Köchy, M.; Hiederer, R.; Freibauer, A.
2014-09-01
The global soil organic carbon (SOC) mass is relevant for the carbon cycle budget. We review current estimates of soil organic carbon stocks (mass/area) and mass (stock × area) in wetlands, permafrost and tropical regions and the world in the upper 1 m of soil. The Harmonized World Soil Database (HWSD) v.1.2 provides one of the most recent and coherent global data sets of SOC, giving a total mass of 2476 Pg. Correcting the HWSD's bulk density of organic soils, especially Histosols, results in a mass of 1062 Pg. The uncertainty of bulk density of Histosols alone introduces a range of -56 to +180 Pg for the estimate of global SOC in the top 1 m, larger than estimates of global soil respiration. We report the spatial distribution of SOC stocks per 0.5 arc minutes, the areal masses of SOC and the quantiles of SOC stocks by continents, wetland types, and permafrost types. Depending on the definition of "wetland", wetland soils contain between 82 and 158 Pg SOC. Incorporating more detailed estimates for permafrost from the Northern Circumpolar Soil Carbon Data Base (496 Pg SOC) and tropical peatland carbon, global soils contain 1324 Pg SOC in the upper 1 m including 421 Pg in tropical soils, whereof 40 Pg occur in tropical wetlands. Global SOC amounts to just under 3000 Pg when estimates for deeper soil layers are included. Variability in estimates is due to variation in definitions of soil units, differences in soil property databases, scarcity of information about soil carbon at depths > 1 m in peatlands, and variation in definitions of "peatland".
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Si; Brown, Joseph N.; Tolic, Nikola
There are several notable challenges inherent to fully characterizing the entirety of the human saliva proteome using bottom-up approaches, including polymorphic isoforms, post-translational modifications, unique splice variants, deletions, and truncations. To address these challenges, we have developed a top-down based liquid chromatography-mass spectrometry (LC-MS) approach, which cataloged 20 major human salivary proteins with a total of 83 proteoforms, containing a broad range of post-translational modifications. Among these proteins, several previously reported disease biomarker proteins were identified at the intact protein level, such as beta-2 microglobulin (B2M). In addition, intact glycosylated proteoforms of several saliva proteins were also characterized, including intactmore » N-glycosylated protein prolactin inducible protein (PIP) and O-glycosylated acidic protein rich protein (aPRP). These characterized proteoforms constitute an intact saliva proteoform database, which was used for quantitative comparison of intact salivary proteoforms among six healthy individuals. Human parotid (PS) and submandibular/sublingual gland (SMSL) secretion samples (2 μg of protein each) from six healthy individuals were compared using RPLC coupled with the 12T FTICR mass spectrometer. Significantly different protein and PTM patterns were resolved with high reproducibility between PS and SMSL glands. The results from this study provide further insight into the potential mechanisms of PTM pathways in oral glandular secretion, expanding our knowledge of this complex yet easily accessible fluid. Intact protein LC-MS approach presented herein can potentially be applied for rapid and accurate identification of biomarkers from only a few microliters of human glandular saliva.« less
Oumeraci, Tonio; Jensen, Vanessa; Talbot, Steven R; Hofmann, Winfried; Kostrzewa, Markus; Schlegelberger, Brigitte; von Neuhoff, Nils; Häussler, Susanne
2015-01-01
Pseudomonas aeruginosa is a gram-negative bacterium that is ubiquitously present in the aerobic biosphere. As an antibiotic-resistant facultative pathogen, it is a major cause of hospital-acquired infections. Its rapid and accurate identification is crucial in clinical and therapeutic environments. In a large-scale MALDI-TOF mass spectrometry-based screen of the Harvard transposon insertion mutant library of P. aeruginosa strain PA14, intact-cell proteome profile spectra of 5547 PA14 transposon mutants exhibiting a plethora of different phenotypes were acquired and analyzed. Of all P. aeruginosa PA14 mutant profiles 99.7% were correctly identified as P. aeruginosa with the Biotyper software on the species level. On the strain level, 99.99% of the profiles were mapped to five different individual P. aeruginosa Biotyper database entries. A principal component analysis-based approach was used to determine the most important discriminatory mass features between these Biotyper groups. Although technical replicas were consistently categorized to specific Biotyper groups in 94.2% of the mutant profiles, biological replicas were not, indicating that the distinct proteotypes are affected by growth conditions. The PA14 mutant profile collection presented here constitutes the largest coherent P. aeruginosa MALDI-TOF spectral dataset publicly available today. Transposon insertions in thousands of different P. aeruginosa genes did not affect species identification from MALDI-TOF mass spectra, clearly demonstrating the robustness of the approach. However, the assignment of the individual spectra to sub-groups proved to be non-consistent in biological replicas, indicating that the differentiation between biotyper groups in this nosocomial pathogen is unassured.
Computation of Calcium Score with Dual Energy CT: A Phantom Study
Kumar, Vidhya; Min, James K.; He, Xin; Raman, Subha V.
2016-01-01
Dual energy computed tomography (DECT) improves material and tissue characterization compared to single energy CT (SECT); we sought to validate coronary calcium quantification in advancing cardiovascular DECT. In an anthropomorphic phantom, agreement between measurements was excellent, and Bland-Altman analysis demonstrated minimal bias. Compared to the known calcium mass for each phantom, calcium mass by DECT was highly accurate. Noncontrast DECT yields accurate calcium measures, and warrants consideration in cardiac protocols for additional tissue characterizations. PMID:27680414
Prakash, Peralam Yegneswaran; Irinyi, Laszlo; Halliday, Catriona; Chen, Sharon; Robert, Vincent; Meyer, Wieland
2017-04-01
The increase in public online databases dedicated to fungal identification is noteworthy. This can be attributed to improved access to molecular approaches to characterize fungi, as well as to delineate species within specific fungal groups in the last 2 decades, leading to an ever-increasing complexity of taxonomic assortments and nomenclatural reassignments. Thus, well-curated fungal databases with substantial accurate sequence data play a pivotal role for further research and diagnostics in the field of mycology. This minireview aims to provide an overview of currently available online databases for the taxonomy and identification of human and animal-pathogenic fungi and calls for the establishment of a cloud-based dynamic data network platform. Copyright © 2017 American Society for Microbiology.
Molar Mass and Second Virial Coefficient of Polyethylene Glycol by Vapor Pressure Osmometry
ERIC Educational Resources Information Center
Schwinefus, Jeffrey J.; Checkal, Caleb; Saksa, Brian; Baka, Nadia; Modi, Kalpit; Rivera, Carlos
2015-01-01
In this laboratory experiment, students determine the number-average molar masses and second virial coefficients of polyethylene glycol (PEG) polymers ranging in molar mass from 200 to 1500 g mol[superscript -1] using vapor pressure osmometry (VPO). Students assess VPO in relation to accurate molar mass calculations of PEG polymers. Additionally,…
Masses of Black Holes in Active Galactic Nuclei
NASA Technical Reports Server (NTRS)
Peterson, Bradley M.
2003-01-01
We present a progress report on a project whose goal is to improve both the precision and accuracy of reverberation-based black-hole masses. Reverberation masses appear to be accurate to a factor of about three, and the black-hole mass/bulge velocity dispersion (M-sigma) relationship appears to be the same in active and quiescent galaxies.
Method for calibrating mass spectrometers
Anderson, Gordon A [Benton City, WA; Brands, Michael D [Richland, WA; Bruce, James E [Schwenksville, PA; Pasa-Tolic, Ljiljana [Richland, WA; Smith, Richard D [Richland, WA
2002-12-24
A method whereby a mass spectra generated by a mass spectrometer is calibrated by shifting the parameters used by the spectrometer to assign masses to the spectra in a manner which reconciles the signal of ions within the spectra having equal mass but differing charge states, or by reconciling ions having known differences in mass to relative values consistent with those known differences. In this manner, the mass spectrometer is calibrated without the need for standards while allowing the generation of a highly accurate mass spectra by the instrument.
Identifying known unknowns using the US EPA's CompTox ...
Chemical features observed using high-resolution mass spectrometry can be tentatively identified using online chemical reference databases by searching molecular formulae and monoisotopic masses and then rank-ordering of the hits using appropriate relevance criteria. The most likely candidate “known unknowns,” which are those chemicals unknown to an investigator but contained within a reference database or literature source, rise to the top of a chemical list when rank-ordered by the number of associated data sources. The U.S. EPA’s CompTox Chemistry Dashboard is a curated and freely available resource for chemistry and computational toxicology research, containing more than 720,000 chemicals of relevance to environmental health science. In this research, the performance of the Dashboard for identifying “known unknowns” was evaluated against that of the online ChemSpider database, one of the primary resources used by mass spectrometrists, using multiple previously studied datasets reported in the peer-reviewed literature totaling 162 chemicals. These chemicals were examined using both applications via molecular formula and monoisotopic mass searches followed by rank-ordering of candidate compounds by associated references or data sources. A greater percentage of chemicals ranked in the top position when using the Dashboard, indicating an advantage of this application over ChemSpider for identifying known unknowns using data source ranking. Addition
Measuring the Mass Distribution in Z is Approximately 0.2 Cluster Lenses with XMM, HST and CFHT
NASA Technical Reports Server (NTRS)
2004-01-01
Being the most massive gravitationally bound objects in the Universe, clusters of galaxies are prime targets for studies of structure formation and evolution. Specifically the comoving space density of virialized clusters of a given mass (or X-ray temperature), but also the frequency and degree of substructure, as well as the shape of the cluster mass profile are quantities whose current values and evolution as a function of lookback time can provide important constraints on the cosmological and physical parameters of structure formation theories. The project funded by NASA grant NAG 5-10041 intended to take such studies to a new level by combining observations of a well-selected cluster sample by three state-of-the-art telescopes: HST, to accurately measure the mass distribution in the cluster core (approx. 0.5 h(sup -1)(sub 50) Mpc) via strong gravitational lensing; CFHT, to measure the large scale mass distribution out to approx. 3 Mpc via weak lensing; and XMM, to measure the gas density and temperature distribution accurately on intermediate scales < 1.5 Mpc. XMM plays a pivotal role in this context as the calibration of X-ray mass measurements through accurate, spatially resolved X-ray temperature measurements (particularly in the cosmologically most sensitive range of kT> 5 keV) is central to the questions outlined above. This set of observations promised to yield the best cluster mass measurements obtained so far for a representative sample, thus allowing us to: 1) Measure the high-mass end of the local cluster mass function; 2) Test predictions of a universal cluster mass profile; 3) calibrate the mass-temperature and temperature-luminosity relations for clusters and the scatter around these relations, which is vital for studies of cluster evolution using the X-ray temperature and X-ray luminosity functions.
Lee, Tai-Fen; Du, Shin-Hei; Teng, Shih-Hua; Liao, Chun-Hsing; Sheng, Wang-Hui; Teng, Lee-Jene
2014-01-01
We evaluated whether the Bruker Biotyper matrix-associated laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) system provides accurate species-level identifications of 147 isolates of aerobically growing Gram-positive rods (GPRs). The bacterial isolates included Nocardia (n = 74), Listeria (n = 39), Kocuria (n = 15), Rhodococcus (n = 10), Gordonia (n = 7), and Tsukamurella (n = 2) species, which had all been identified by conventional methods, molecular methods, or both. In total, 89.7% of Listeria monocytogenes, 80% of Rhodococcus species, 26.7% of Kocuria species, and 14.9% of Nocardia species (n = 11, all N. nova and N. otitidiscaviarum) were correctly identified to the species level (score values, ≥2.0). A clustering analysis of spectra generated by the Bruker Biotyper identified six clusters of Nocardia species, i.e., cluster 1 (N. cyriacigeorgica), cluster 2 (N. brasiliensis), cluster 3 (N. farcinica), cluster 4 (N. puris), cluster 5 (N. asiatica), and cluster 6 (N. beijingensis), based on the six peaks generated by ClinProTools with the genetic algorithm, i.e., m/z 2,774.477 (cluster 1), m/z 5,389.792 (cluster 2), m/z 6,505.720 (cluster 3), m/z 5,428.795 (cluster 4), m/z 6,525.326 (cluster 5), and m/z 16,085.216 (cluster 6). Two clusters of L. monocytogenes spectra were also found according to the five peaks, i.e., m/z 5,594.85, m/z 6,184.39, and m/z 11,187.31, for cluster 1 (serotype 1/2a) and m/z 5,601.21 and m/z 11,199.33 for cluster 2 (serotypes 1/2b and 4b). The Bruker Biotyper system was unable to accurately identify Nocardia (except for N. nova and N. otitidiscaviarum), Tsukamurella, or Gordonia species. Continuous expansion of the MALDI-TOF MS databases to include more GPRs is necessary. PMID:24759706
NASA Astrophysics Data System (ADS)
Jawak, Shridhar D.; Luis, Alvarinho J.
2016-05-01
Digital elevation model (DEM) is indispensable for analysis such as topographic feature extraction, ice sheet melting, slope stability analysis, landscape analysis and so on. Such analysis requires a highly accurate DEM. Available DEMs of Antarctic region compiled by using radar altimetry and the Antarctic digital database indicate elevation variations of up to hundreds of meters, which necessitates the generation of local improved DEM. An improved DEM of the Schirmacher Oasis, East Antarctica has been generated by synergistically fusing satellite-derived laser altimetry data from Geoscience Laser Altimetry System (GLAS), Radarsat Antarctic Mapping Project (RAMP) elevation data and Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) global elevation data (GDEM). This is a characteristic attempt to generate a DEM of any part of Antarctica by fusing multiple elevation datasets, which is essential to model the ice elevation change and address the ice mass balance. We analyzed a suite of interpolation techniques for constructing a DEM from GLAS, RAMP and ASTER DEM-based point elevation datasets, in order to determine the level of confidence with which the interpolation techniques can generate a better interpolated continuous surface, and eventually improve the elevation accuracy of DEM from synergistically fused RAMP, GLAS and ASTER point elevation datasets. The DEM presented in this work has a vertical accuracy (≈ 23 m) better than RAMP DEM (≈ 57 m) and ASTER DEM (≈ 64 m) individually. The RAMP DEM and ASTER DEM elevations were corrected using differential GPS elevations as ground reference data, and the accuracy obtained after fusing multitemporal datasets is found to be improved than that of existing DEMs constructed by using RAMP or ASTER alone. This is our second attempt of fusing multitemporal, multisensory and multisource elevation data to generate a DEM of Antarctica, in order to address the ice elevation change and address the ice mass balance. Our approach focuses on the strengths of each elevation data source to produce an accurate elevation model.
The TW Hydrae association: trigonometric parallaxes and kinematic analysis
NASA Astrophysics Data System (ADS)
Ducourant, C.; Teixeira, R.; Galli, P. A. B.; Le Campion, J. F.; Krone-Martins, A.; Zuckerman, B.; Chauvin, G.; Song, I.
2014-03-01
Context. The nearby TW Hydrae association (TWA) is currently a benchmark for the study of the formation and evolution of young low-mass stars, circumstellar disks, and the imaging detection of planetary companions. For these studies, it is crucial to evaluate the distance to group members in order to access their physical properties. Membership of several stars is strongly debated and age estimates vary from one author to another with doubts about coevality. Aims: We revisit the kinematic properties of the TWA in light of new trigonometric parallaxes and proper motions to derive the dynamical age of the association and physical parameters of kinematic members. Methods: Using observations performed with the New Technology Telescope (NTT) from ESO we measured trigonometric parallaxes and proper motions for 13 stars in TWA. Results: With the convergent point method we identify a co-moving group with 31 TWA stars. We deduce kinematic distances for seven members of the moving group that lack trigonometric parallaxes. A traceback strategy is applied to the stellar space motions of a selection of 16 of the co-moving objects with accurate and reliable data yielding a dynamical age for the association of t ≃ 7.5 ± 0.7 Myr. Using our new parallaxes and photometry available in the literature we derive stellar ages and masses from theoretical evolutionary models. Conclusions: With new parallax and proper motion measurements from this work and current astrometric catalogs we provide an improved and accurate database for TWA stars to be used in kinematical analysis. We conclude that the dynamical age obtained via traceback strategy is consistent with previous age estimates for the TWA, and is also compatible with the average ages derived in the present paper from evolutionary models for pre-main-sequence stars. Based on observations performed at the European Southern Observatory, Chile (79.C-0229, 81.C-0143, 82.C-0103, 83.C-0102, 84.C-0014).
ANALYSIS OF DISCRIMINATING FACTORS IN HUMAN ACTIVITIES THAT AFFECT EXPOSURE
Accurately modeling exposure to particulate matter (PM) and other pollutants ultimately involves the utilization of human location-activity databases to assist in understanding the potential variability of microenvironmental exposures. This paper critically considers and stati...
eQuilibrator--the biochemical thermodynamics calculator.
Flamholz, Avi; Noor, Elad; Bar-Even, Arren; Milo, Ron
2012-01-01
The laws of thermodynamics constrain the action of biochemical systems. However, thermodynamic data on biochemical compounds can be difficult to find and is cumbersome to perform calculations with manually. Even simple thermodynamic questions like 'how much Gibbs energy is released by ATP hydrolysis at pH 5?' are complicated excessively by the search for accurate data. To address this problem, eQuilibrator couples a comprehensive and accurate database of thermodynamic properties of biochemical compounds and reactions with a simple and powerful online search and calculation interface. The web interface to eQuilibrator (http://equilibrator.weizmann.ac.il) enables easy calculation of Gibbs energies of compounds and reactions given arbitrary pH, ionic strength and metabolite concentrations. The eQuilibrator code is open-source and all thermodynamic source data are freely downloadable in standard formats. Here we describe the database characteristics and implementation and demonstrate its use.
eQuilibrator—the biochemical thermodynamics calculator
Flamholz, Avi; Noor, Elad; Bar-Even, Arren; Milo, Ron
2012-01-01
The laws of thermodynamics constrain the action of biochemical systems. However, thermodynamic data on biochemical compounds can be difficult to find and is cumbersome to perform calculations with manually. Even simple thermodynamic questions like ‘how much Gibbs energy is released by ATP hydrolysis at pH 5?’ are complicated excessively by the search for accurate data. To address this problem, eQuilibrator couples a comprehensive and accurate database of thermodynamic properties of biochemical compounds and reactions with a simple and powerful online search and calculation interface. The web interface to eQuilibrator (http://equilibrator.weizmann.ac.il) enables easy calculation of Gibbs energies of compounds and reactions given arbitrary pH, ionic strength and metabolite concentrations. The eQuilibrator code is open-source and all thermodynamic source data are freely downloadable in standard formats. Here we describe the database characteristics and implementation and demonstrate its use. PMID:22064852
[Practical approach to infection control and antimicrobial stewardship by medical technologists].
Komori, Toshiaki; Yamada, Yukiji; Kimura, Takeshi; Kosaka, Tadashi; Nakanishi, Masaki; Fujitomo, Yumiko; Fujita, Naohisa
2013-04-01
Since establishing an antimicrobial management team (AMT) in 2003, we have been promoting both appropriate diagnosis and treatment and improving the prognosis of hospitalized patients with infections. AMT is composed of 4 doctors, 2 nurses, 2 pharmacists and one medical technologist. AMT members meet twice a week and discuss patients with positive blood cultures, with prescribed anti-MRSA drugs and suspected infections. Antimicrobial prescription and clinical laboratory data are obtained from the database of electric medical records and microbiological data from the laboratory database system. The initial step in infection control and antimicrobial stewardship is an accurate diagnosis of infection. Clinical microbiology laboratories play a critical role in infection control and antimicrobial stewardship by reporting accurate and timely results of both bacterial identification and antimicrobial susceptibility tests. Medical technologists are required to develop better competency and proficiency about clinical microbiology in both infection control and antimicrobial stewardship.
Domain Regeneration for Cross-Database Micro-Expression Recognition
NASA Astrophysics Data System (ADS)
Zong, Yuan; Zheng, Wenming; Huang, Xiaohua; Shi, Jingang; Cui, Zhen; Zhao, Guoying
2018-05-01
In this paper, we investigate the cross-database micro-expression recognition problem, where the training and testing samples are from two different micro-expression databases. Under this setting, the training and testing samples would have different feature distributions and hence the performance of most existing micro-expression recognition methods may decrease greatly. To solve this problem, we propose a simple yet effective method called Target Sample Re-Generator (TSRG) in this paper. By using TSRG, we are able to re-generate the samples from target micro-expression database and the re-generated target samples would share same or similar feature distributions with the original source samples. For this reason, we can then use the classifier learned based on the labeled source samples to accurately predict the micro-expression categories of the unlabeled target samples. To evaluate the performance of the proposed TSRG method, extensive cross-database micro-expression recognition experiments designed based on SMIC and CASME II databases are conducted. Compared with recent state-of-the-art cross-database emotion recognition methods, the proposed TSRG achieves more promising results.
Assigning statistical significance to proteotypic peptides via database searches
Alves, Gelio; Ogurtsov, Aleksey Y.; Yu, Yi-Kuo
2011-01-01
Querying MS/MS spectra against a database containing only proteotypic peptides reduces data analysis time due to reduction of database size. Despite the speed advantage, this search strategy is challenged by issues of statistical significance and coverage. The former requires separating systematically significant identifications from less confident identifications, while the latter arises when the underlying peptide is not present, due to single amino acid polymorphisms (SAPs) or post-translational modifications (PTMs), in the proteotypic peptide libraries searched. To address both issues simultaneously, we have extended RAId’s knowledge database to include proteotypic information, utilized RAId’s statistical strategy to assign statistical significance to proteotypic peptides, and modified RAId’s programs to allow for consideration of proteotypic information during database searches. The extended database alleviates the coverage problem since all annotated modifications, even those occurred within proteotypic peptides, may be considered. Taking into account the likelihoods of observation, the statistical strategy of RAId provides accurate E-value assignments regardless whether a candidate peptide is proteotypic or not. The advantage of including proteotypic information is evidenced by its superior retrieval performance when compared to regular database searches. PMID:21055489
Creating databases for biological information: an introduction.
Stein, Lincoln
2002-08-01
The essence of bioinformatics is dealing with large quantities of information. Whether it be sequencing data, microarray data files, mass spectrometric data (e.g., fingerprints), the catalog of strains arising from an insertional mutagenesis project, or even large numbers of PDF files, there inevitably comes a time when the information can simply no longer be managed with files and directories. This is where databases come into play. This unit briefly reviews the characteristics of several database management systems, including flat file, indexed file, and relational databases, as well as ACeDB. It compares their strengths and weaknesses and offers some general guidelines for selecting an appropriate database management system.
Quantitative aspects of inductively coupled plasma mass spectrometry
NASA Astrophysics Data System (ADS)
Bulska, Ewa; Wagner, Barbara
2016-10-01
Accurate determination of elements in various kinds of samples is essential for many areas, including environmental science, medicine, as well as industry. Inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool enabling multi-elemental analysis of numerous matrices with high sensitivity and good precision. Various calibration approaches can be used to perform accurate quantitative measurements by ICP-MS. They include the use of pure standards, matrix-matched standards, or relevant certified reference materials, assuring traceability of the reported results. This review critically evaluates the advantages and limitations of different calibration approaches, which are used in quantitative analyses by ICP-MS. Examples of such analyses are provided. This article is part of the themed issue 'Quantitative mass spectrometry'.
NASA Astrophysics Data System (ADS)
Hong, Pengyu; Sun, Hui; Sha, Long; Pu, Yi; Khatri, Kshitij; Yu, Xiang; Tang, Yang; Lin, Cheng
2017-08-01
A major challenge in glycomics is the characterization of complex glycan structures that are essential for understanding their diverse roles in many biological processes. We present a novel efficient computational approach, named GlycoDeNovo, for accurate elucidation of the glycan topologies from their tandem mass spectra. Given a spectrum, GlycoDeNovo first builds an interpretation-graph specifying how to interpret each peak using preceding interpreted peaks. It then reconstructs the topologies of peaks that contribute to interpreting the precursor ion. We theoretically prove that GlycoDeNovo is highly efficient. A major innovative feature added to GlycoDeNovo is a data-driven IonClassifier which can be used to effectively rank candidate topologies. IonClassifier is automatically learned from experimental spectra of known glycans to distinguish B- and C-type ions from all other ion types. Our results showed that GlycoDeNovo is robust and accurate for topology reconstruction of glycans from their tandem mass spectra. [Figure not available: see fulltext.
Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging
NASA Technical Reports Server (NTRS)
Zimmerli, Gregory A.; Buchanan, David A.; Follo, Jeffrey C.; Vaden, Karl R.; Wagner, James D.; Asipauskas, Marius; Herlacher, Michael D.
2010-01-01
Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank hardware, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank harare, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the
High Temperature, high pressure equation of state density correlations and viscosity correlations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tapriyal, D.; Enick, R.; McHugh, M.
2012-07-31
Global increase in oil demand and depleting reserves has derived a need to find new oil resources. To find these untapped reservoirs, oil companies are exploring various remote and harsh locations such as deep waters in Gulf of Mexico, remote arctic regions, unexplored deep deserts, etc. Further, the depth of new oil/gas wells being drilled has increased considerably to tap these new resources. With the increase in the well depth, the bottomhole temperature and pressure are also increasing to extreme values (i.e. up to 500 F and 35,000 psi). The density and viscosity of natural gas and crude oil atmore » reservoir conditions are critical fundamental properties required for accurate assessment of the amount of recoverable petroleum within a reservoir and the modeling of the flow of these fluids within the porous media. These properties are also used to design appropriate drilling and production equipment such as blow out preventers, risers, etc. With the present state of art, there is no accurate database for these fluid properties at extreme conditions. As we have begun to expand this experimental database it has become apparent that there are neither equations of state for density or transport models for viscosity that can be used to predict these fundamental properties of multi-component hydrocarbon mixtures over a wide range of temperature and pressure. Presently, oil companies are using correlations based on lower temperature and pressure databases that exhibit an unsatisfactory predictive capability at extreme conditions (e.g. as great as {+-} 50%). From the perspective of these oil companies that are committed to safely producing these resources, accurately predicting flow rates, and assuring the integrity of the flow, the absence of an extensive experimental database at extreme conditions and models capable of predicting these properties over an extremely wide range of temperature and pressure (including extreme conditions) makes their task even more daunting.« less
Seliske, Laura; Pickett, William; Bates, Rebecca; Janssen, Ian
2012-01-01
Many studies examining the food retail environment rely on geographic information system (GIS) databases for location information. The purpose of this study was to validate information provided by two GIS databases, comparing the positional accuracy of food service places within a 1 km circular buffer surrounding 34 schools in Ontario, Canada. A commercial database (InfoCanada) and an online database (Yellow Pages) provided the addresses of food service places. Actual locations were measured using a global positioning system (GPS) device. The InfoCanada and Yellow Pages GIS databases provided the locations for 973 and 675 food service places, respectively. Overall, 749 (77.1%) and 595 (88.2%) of these were located in the field. The online database had a higher proportion of food service places found in the field. The GIS locations of 25% of the food service places were located within approximately 15 m of their actual location, 50% were within 25 m, and 75% were within 50 m. This validation study provided a detailed assessment of errors in the measurement of the location of food service places in the two databases. The location information was more accurate for the online database, however, when matching criteria were more conservative, there were no observed differences in error between the databases. PMID:23066385
Seliske, Laura; Pickett, William; Bates, Rebecca; Janssen, Ian
2012-08-01
Many studies examining the food retail environment rely on geographic information system (GIS) databases for location information. The purpose of this study was to validate information provided by two GIS databases, comparing the positional accuracy of food service places within a 1 km circular buffer surrounding 34 schools in Ontario, Canada. A commercial database (InfoCanada) and an online database (Yellow Pages) provided the addresses of food service places. Actual locations were measured using a global positioning system (GPS) device. The InfoCanada and Yellow Pages GIS databases provided the locations for 973 and 675 food service places, respectively. Overall, 749 (77.1%) and 595 (88.2%) of these were located in the field. The online database had a higher proportion of food service places found in the field. The GIS locations of 25% of the food service places were located within approximately 15 m of their actual location, 50% were within 25 m, and 75% were within 50 m. This validation study provided a detailed assessment of errors in the measurement of the location of food service places in the two databases. The location information was more accurate for the online database, however, when matching criteria were more conservative, there were no observed differences in error between the databases.
Collision Cross Section (CCS) Database: An Additional Measure to Characterize Steroids.
Hernández-Mesa, Maykel; Le Bizec, Bruno; Monteau, Fabrice; García-Campaña, Ana M; Dervilly-Pinel, Gaud
2018-04-03
Ion mobility spectrometry enhances the performance characteristics of liquid chromatography-mass spectrometry workflows intended to steroid profiling by providing a new separation dimension and a novel characterization parameter, the so-called collision cross section (CCS). This work proposes the first CCS database for 300 steroids (i.e., endogenous, including phase I and phase II metabolites, and exogenous synthetic compounds), which involves 1080 ions and covers the CCS of 127 androgens, 84 estrogens, 50 corticosteroids, and 39 progestagens. This large database provides information related to all the ionized species identified for each steroid in positive electrospray ionization mode as well as for estrogens in negative ionization mode. CCS values have been measured using nitrogen as drift gas in the ion mobility cell. Generally, direct correlation exists between mass-to-charge ratio ( m/ z) and CCS because both are related parameters. However, several steroids mainly steroid glucuronides and steroid esters have been characterized as more compact or elongated molecules than expected. In such cases, CCS results in additional relevant information to retention time and mass spectral data for the identification of steroids. Moreover, several isomeric steroid pairs (e.g., 5β-androstane-3,17-dione and 5α-androstane-3,17-dione) have been separated based on their CCS differences. These results indicate that adding the CCS to databases in analytical workflows increases selectivity, thus improving the confidence in steroids analysis. Consequences in terms of identification and quantification are discussed. Quality criteria and a construction of an interlaboratory reproducibility approach are also reported for the obtained CCS values. The CCS database described here is made publicly available.
Benitex, Yulia; McNaney, Colleen A; Luchetti, David; Schaeffer, Eric; Olah, Timothy V; Morgan, Daniel G; Drexler, Dieter M
2013-08-30
Research on disorders of the central nervous system (CNS) has shown that an imbalance in the levels of specific endogenous neurotransmitters may underlie certain CNS diseases. These alterations in neurotransmitter levels may provide insight into pathophysiology, but can also serve as disease and pharmacodynamic biomarkers. To measure these potential biomarkers in vivo, the relevant sample matrix is cerebrospinal fluid (CSF), which is in equilibrium with the brain's interstitial fluid and circulates through the ventricular system of the brain and spinal cord. Accurate analysis of these potential biomarkers can be challenging due to low CSF sample volume, low analyte levels, and potential interferences from other endogenous compounds. A protocol has been established for effective method development of bioanalytical assays for endogenous compounds in CSF. Database searches and standard-addition experiments are employed to qualify sample preparation and specificity of the detection thus evaluating accuracy and precision. This protocol was applied to the study of the histaminergic neurotransmitter system and the analysis of histamine and its metabolite 1-methylhistamine in rat CSF. The protocol resulted in a specific and sensitive novel method utilizing pre-column derivatization ultra high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS), which is also capable of separating an endogenous interfering compound, identified as taurine, from the analytes of interest. Copyright © 2013 John Wiley & Sons, Ltd.
Bernfur, Katja; Larsson, Olaf; Larsson, Christer; Gustavsson, Niklas
2013-01-01
Metabolic labeling of proteins with a stable isotope (15N) in intact Arabidopsis plants was used for accurate determination by mass spectrometry of differences in protein abundance between plasma membranes isolated from leaves and roots. In total, 703 proteins were identified, of which 188 were predicted to be integral membrane proteins. Major classes were transporters, receptors, proteins involved in membrane trafficking and cell wall-related proteins. Forty-one of the integral proteins, including nine of the 13 isoforms of the PIP (plasma membrane intrinsic protein) aquaporin subfamily, could be identified by peptides unique to these proteins, which made it possible to determine their relative abundance in leaf and root tissue. In addition, peptides shared between isoforms gave information on the proportions of these isoforms. A comparison between our data for protein levels and corresponding data for mRNA levels in the widely used database Genevestigator showed an agreement for only about two thirds of the proteins. By contrast, localization data available in the literature for 21 of the 41 proteins show a much better agreement with our data, in particular data based on immunostaining of proteins and GUS-staining of promoter activity. Thus, although mRNA levels may provide a useful approximation for protein levels, detection and quantification of isoform-specific peptides by proteomics should generate the most reliable data for the proteome. PMID:23990937
Nontarget approach for environmental monitoring by GC × GC-HRTOFMS in the Tokyo Bay basin.
Zushi, Yasuyuki; Hashimoto, Shunji; Tanabe, Kiyoshi
2016-08-01
In this study, we developed an approach for sequential nontarget and target screening for the rapid and efficient analysis of multiple samples as an environmental monitoring using a comprehensive two-dimensional gas chromatograph coupled to a high resolution time-of-flight mass spectrometer (GC × GC-HRTOFMS). A key feature of the approach was the construction of an accurate mass spectral database learned from the sample via nontarget screening. To enhance the detection power in the nontarget screening, a global spectral deconvolution procedure based on non-negative matrix factorization was applied. The approach was applied to the monitoring of rivers in the Tokyo Bay basin. The majority of the compounds detected by the nontarget screening were alkyl chain-based compounds (55%). In the quantitative target screening based on the output from the nontarget screening, particularly high levels of organophosphorus flame retardants (median concentrations of 31, 116 and 141 ng l(-1) for TDCPP, TCIPP and TBEP, respectively) were observed among the target compounds. Flame retardants used for household furniture and building materials were detected in river basins where buildings and arterial traffic were dominated. The developed GC × GC-HRTOFMS approach was efficient and effective for environmental monitoring and provided valuable new information on various aspects of monitoring in the context of environmental management. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
2005-01-01
Topics covered include: Apparatus Characterizes Transient Voltages in Real Time; Measuring Humidity in Sealed Glass Encasements; Adaptable System for Vehicle Health and Usage Monitoring; Miniature Focusing Time-of-Flight Mass Spectrometer; Cryogenic High-Sensitivity Magnetometer; Wheel Electrometer System; Carbon-Nanotube Conductive Layers for Thin-Film Solar Cells; Patch Antenna Fed via Unequal-Crossed-Arm Aperture; LC Circuits for Diagnosing Embedded Piezoelectric Devices; Nanowire Thermoelectric Devices; Code for Analyzing and Designing Spacecraft Power System Radiators; Decision Support for Emergency Operations Centers; NASA Records Database; Real-Time Principal- Component Analysis; Fuzzy/Neural Software Estimates Costs of Rocket- Engine Tests; Multicomponent, Rare-Earth-Doped Thermal-Barrier Coatings; Reactive Additives for Phenylethynyl-Containing Resins; Improved Gear Shapes for Face Worm Gear Drives; Alternative Way of Shifting Mass to Move a Spherical Robot; Parylene C as a Sacrificial Material for Microfabrication; In Situ Electrochemical Deposition of Microscopic Wires; Improved Method of Manufacturing SiC Devices; Microwave Treatment of Prostate Cancer and Hyperplasia; Ferroelectric Devices Emit Charged Particles and Radiation; Dusty-Plasma Particle Accelerator; Frozen-Plug Technique for Liquid-Oxygen Plumbing; Shock Waves in a Bose-Einstein Condensate; Progress on a Multichannel, Dual-Mixer Stability Analyzer; Development of Carbon- Nanotube/Polymer Composites; Thermal Imaging of Earth for Accurate Pointing of Deep-Space Antennas; Modifications of a Composite-Material Combustion Chamber; Modeling and Diagnostic Software for Liquefying- Fuel Rockets; and Spacecraft Antenna Clusters for High EIRP.
Using CRANID to test the population affinity of known crania.
Kallenberger, Lauren; Pilbrow, Varsha
2012-11-01
CRANID is a statistical program used to infer the source population of a cranium of unknown origin by comparing its cranial dimensions with a worldwide craniometric database. It has great potential for estimating ancestry in archaeological, forensic and repatriation cases. In this paper we test the validity of CRANID in classifying crania of known geographic origin. Twenty-three crania of known geographic origin but unknown sex were selected from the osteological collections of the University of Melbourne. Only 18 crania showed good statistical match with the CRANID database. Without considering accuracy of sex allocation, 11 crania were accurately classified into major geographic regions and nine were correctly classified to geographically closest available reference populations. Four of the five crania with poor statistical match were nonetheless correctly allocated to major geographical regions, although none was accurately assigned to geographically closest reference samples. We conclude that if sex allocations are overlooked, CRANID can accurately assign 39% of specimens to geographically closest matching reference samples and 48% to major geographic regions. Better source population representation may improve goodness of fit, but known sex-differentiated samples are needed to further test the utility of CRANID. © 2012 The Authors Journal of Anatomy © 2012 Anatomical Society.
Advances in structure elucidation of small molecules using mass spectrometry
Fiehn, Oliver
2010-01-01
The structural elucidation of small molecules using mass spectrometry plays an important role in modern life sciences and bioanalytical approaches. This review covers different soft and hard ionization techniques and figures of merit for modern mass spectrometers, such as mass resolving power, mass accuracy, isotopic abundance accuracy, accurate mass multiple-stage MS(n) capability, as well as hybrid mass spectrometric and orthogonal chromatographic approaches. The latter part discusses mass spectral data handling strategies, which includes background and noise subtraction, adduct formation and detection, charge state determination, accurate mass measurements, elemental composition determinations, and complex data-dependent setups with ion maps and ion trees. The importance of mass spectral library search algorithms for tandem mass spectra and multiple-stage MS(n) mass spectra as well as mass spectral tree libraries that combine multiple-stage mass spectra are outlined. The successive chapter discusses mass spectral fragmentation pathways, biotransformation reactions and drug metabolism studies, the mass spectral simulation and generation of in silico mass spectra, expert systems for mass spectral interpretation, and the use of computational chemistry to explain gas-phase phenomena. A single chapter discusses data handling for hyphenated approaches including mass spectral deconvolution for clean mass spectra, cheminformatics approaches and structure retention relationships, and retention index predictions for gas and liquid chromatography. The last section reviews the current state of electronic data sharing of mass spectra and discusses the importance of software development for the advancement of structure elucidation of small molecules. Electronic supplementary material The online version of this article (doi:10.1007/s12566-010-0015-9) contains supplementary material, which is available to authorized users. PMID:21289855
Proteomics: Protein Identification Using Online Databases
ERIC Educational Resources Information Center
Eurich, Chris; Fields, Peter A.; Rice, Elizabeth
2012-01-01
Proteomics is an emerging area of systems biology that allows simultaneous study of thousands of proteins expressed in cells, tissues, or whole organisms. We have developed this activity to enable high school or college students to explore proteomic databases using mass spectrometry data files generated from yeast proteins in a college laboratory…
'Isotopo' a database application for facile analysis and management of mass isotopomer data.
Ahmed, Zeeshan; Zeeshan, Saman; Huber, Claudia; Hensel, Michael; Schomburg, Dietmar; Münch, Richard; Eylert, Eva; Eisenreich, Wolfgang; Dandekar, Thomas
2014-01-01
The composition of stable-isotope labelled isotopologues/isotopomers in metabolic products can be measured by mass spectrometry and supports the analysis of pathways and fluxes. As a prerequisite, the original mass spectra have to be processed, managed and stored to rapidly calculate, analyse and compare isotopomer enrichments to study, for instance, bacterial metabolism in infection. For such applications, we provide here the database application 'Isotopo'. This software package includes (i) a database to store and process isotopomer data, (ii) a parser to upload and translate different data formats for such data and (iii) an improved application to process and convert signal intensities from mass spectra of (13)C-labelled metabolites such as tertbutyldimethylsilyl-derivatives of amino acids. Relative mass intensities and isotopomer distributions are calculated applying a partial least square method with iterative refinement for high precision data. The data output includes formats such as graphs for overall enrichments in amino acids. The package is user-friendly for easy and robust data management of multiple experiments. The 'Isotopo' software is available at the following web link (section Download): http://spp1316.uni-wuerzburg.de/bioinformatics/isotopo/. The package contains three additional files: software executable setup (installer), one data set file (discussed in this article) and one excel file (which can be used to convert data from excel to '.iso' format). The 'Isotopo' software is compatible only with the Microsoft Windows operating system. http://spp1316.uni-wuerzburg.de/bioinformatics/isotopo/. © The Author(s) 2014. Published by Oxford University Press.
NASA Astrophysics Data System (ADS)
Stebel, Kerstin; Prata, Fred; Theys, Nicolas; Tampellini, Lucia; Kamstra, Martijn; Zehner, Claus
2014-05-01
Over the last few years there has been a recognition of the utility of satellite measurements to identify and track volcanic emissions that present a natural hazard to human populations. Mitigation of the volcanic hazard to life and the environment requires understanding of the properties of volcanic emissions, identifying the hazard in near real-time and being able to provide timely and accurate forecasts to affected areas. Amongst the many ways to measure volcanic emissions, satellite remote sensing is capable of providing global quantitative retrievals of important microphysical parameters such as ash mass loading, ash particle effective radius, infrared optical depth, SO2 partial and total column abundance, plume altitude, aerosol optical depth and aerosol absorbing index. The eruption of Eyjafjallajökull in April May, 2010 led to increased research and measurement programs to better characterize properties of volcanic ash and the need to establish a data-base in which to store and access these data was confirmed. The European Space Agency (ESA) has recognized the importance of having a quality controlled data-base of satellite retrievals and has funded an activity called Volcanic Ash Strategic Initiative Team VAST (vast.nilu.no) to develop novel remote sensing retrieval schemes and a data-base, initially focused on several recent hazardous volcanic eruptions. In addition, the data-base will host satellite and validation data sets provided from the ESA projects Support to Aviation Control Service SACS (sacs.aeronomie.be) and Study on an end-to-end system for volcanic ash plume monitoring and prediction SMASH. Starting with data for the eruptions of Eyjafjallajökull, Grímsvötn, and Kasatochi, satellite retrievals for Puyhue-Cordon Caulle, Nabro, Merapi, Okmok, Kasatochi and Sarychev Peak will eventually be ingested. Dispersion model simulations are also being included in the data-base. Several atmospheric dispersion models (FLEXPART, SILAM and WRF-Chem) are used in VAST to simulate the dispersion of volcanic ash and SO2 emitted during an eruption. Source terms and dispersion model results will be given. In time, data from conventional in situ sampling instruments, airborne and ground-based remote sensing platforms and other meta-data (bulk ash and gas properties, volcanic setting, volcanic eruption chronologies, potential impacts etc.) will be added. Important applications of the data-base are illustrated related to the ash/aviation problem and to estimating SO2 fluxes from active volcanoes-as a means to diagnose future unrest. The data-base has the potential to provide the natural hazards community with a dynamic atmospheric volcanic hazards map and will be a valuable tool particularly for aviation.
Sleiman, Sue; Halliday, Catriona L; Chapman, Belinda; Brown, Mitchell; Nitschke, Joanne; Lau, Anna F; Chen, Sharon C-A
2016-08-01
We developed an Australian database for the identification of Aspergillus, Scedosporium, and Fusarium species (n = 28) by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). In a challenge against 117 isolates, species identification significantly improved when the in-house-built database was combined with the Bruker Filamentous Fungi Library compared with that for the Bruker library alone (Aspergillus, 93% versus 69%; Fusarium, 84% versus 42%; and Scedosporium, 94% versus 18%, respectively). Copyright © 2016, American Society for Microbiology. All Rights Reserved.
A Mass Spectrometer Simulator in Your Computer
ERIC Educational Resources Information Center
Gagnon, Michel
2012-01-01
Introduced to study components of ionized gas, the mass spectrometer has evolved into a highly accurate device now used in many undergraduate and research laboratories. Unfortunately, despite their importance in the formation of future scientists, mass spectrometers remain beyond the financial reach of many high schools and colleges. As a result,…
Lum, Kirsten J; Newcomb, Craig W; Roy, Jason A; Carbonari, Dena M; Saine, M Elle; Cardillo, Serena; Bhullar, Harshvinder; Gallagher, Arlene M; Lo Re, Vincent
2017-01-01
The extent to which days' supply data are missing in pharmacoepidemiologic databases and effective methods for estimation is unknown. We determined the percentage of missing days' supply on prescription and patient levels for oral anti-diabetic drugs (OADs) and evaluated three methods for estimating days' supply within the Clinical Practice Research Datalink (CPRD) and The Health Improvement Network (THIN). We estimated the percentage of OAD prescriptions and patients with missing days' supply in each database from 2009 to 2013. Within a random sample of prescriptions with known days' supply, we measured the accuracy of three methods to estimate missing days' supply by imputing the following: (1) 28 days' supply, (2) mode number of tablets/day by drug strength and number of tablets/prescription, and (3) number of tablets/day via a machine learning algorithm. We determined incidence rates (IRs) of acute myocardial infarction (AMI) using each method to evaluate the impact on ascertainment of exposure time and outcomes. Days' supply was missing for 24 % of OAD prescriptions in CPRD and 33 % in THIN (affecting 48 and 57 % of patients, respectively). Methods 2 and 3 were very accurate in estimating days' supply for OADs prescribed at a consistent number of tablets/day. Method 3 was more accurate for OADs prescribed at varying number of tablets/day. IRs of AMI were similar across methods for most OADs. Missing days' supply is a substantial problem in both databases. Method 2 is easy and very accurate for most OADs and results in IRs comparable to those from method 3.
Estimating liver cancer deaths in Thailand based on verbal autopsy study.
Waeto, Salwa; Pipatjaturon, Nattakit; Tongkumchum, Phattrawan; Choonpradub, Chamnein; Saelim, Rattikan; Makaje, Nifatamah
2014-01-01
Liver cancer mortality is high in Thailand but utility of related vital statistics is limited due to national vital registration (VR) data being under reported for specific causes of deaths. Accurate methodologies and reliable supplementary data are needed to provide worthy national vital statistics. This study aimed to model liver cancer deaths based on verbal autopsy (VA) study in 2005 to provide more accurate estimates of liver cancer deaths than those reported. The results were used to estimate number of liver cancer deaths during 2000-2009. A verbal autopsy (VA) was carried out in 2005 based on a sample of 9,644 deaths from nine provinces and it provided reliable information on causes of deaths by gender, age group, location of deaths in or outside hospital, and causes of deaths of the VR database. Logistic regression was used to model liver cancer deaths and other variables. The estimated probabilities from the model were applied to liver cancer deaths in the VR database, 2000-2009. Thus, the more accurately VA-estimated numbers of liver cancer deaths were obtained. The model fits the data quite well with sensitivity 0.64. The confidence intervals from statistical model provide the estimates and their precisions. The VA-estimated numbers of liver cancer deaths were higher than the corresponding VR database with inflation factors 1.56 for males and 1.64 for females. The statistical methods used in this study can be applied to available mortality data in developing countries where their national vital registration data are of low quality and supplementary reliable data are available.
Maximum heat of mass concrete - phase 2.
DOT National Transportation Integrated Search
2016-11-01
The main findings and recommendations from this study are as follows: : (1) The database of adiabatic temperature rise tables which was developed in this study can be used in the DIANA software for the modeling of mass concrete structures. : (2) Clas...
Curating and sharing structures and spectra for the environmental community
The increasing popularity of high mass accuracy non-target mass spectrometry methods has yielded extensive identification efforts based on spectral and chemical compound databases in the environmental community and beyond. Increasingly, new methods are relying on open data resour...
Identifying known unknowns using the US EPA's CompTox Chemistry Dashboard
Chemical features observed using high-resolution mass spectrometry can be tentatively identified using online chemical reference databases by searching molecular formulae and monoisotopic masses and then rank-ordering of the hits using appropriate relevance criteria. The most li...
Zhang, Huifang; Zhang, Yongchan; Gao, Yuan; Xu, Li; Lv, Jing; Wang, Yingtong; Zhang, Jianzhong; Shao, Zhujun
2013-01-01
Nontypable Haemophilus influenzae (NTHi) and Haemophilus haemolyticus exhibit different pathogenicities, but to date, there remains no definitive and reliable strategy for differentiating these strains. In this study, we evaluated matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) as a potential method for differentiating NTHi and H. haemolyticus. The phylogenetic analysis of concatenated 16S rRNA and recombinase A (recA) gene sequences, outer membrane protein P6 gene sequencing and single-gene PCR were used as reference methods. The original reference database (ORD, provided with the Biotyper software) and new reference database (NRD, extended with Chinese strains) were compared for the evaluation of MALDI-TOF MS. Through a search of the ORD, 76.9% of the NTHi (40/52) and none of the H. haemolyticus (0/20) strains were identified at the species level. However, all NTHi and H. haemolyticus strains used for identification were accurately recognized at the species level when searching the NRD. From the dendrogram clustering of the main spectra projections, the Chinese and foreign H. influenzae reference strains were categorized into two distinct groups, and H. influenzae and H. haemolyticus were also separated into two categories. Compared to the existing methods, MALDI-TOF MS has the advantage of integrating high throughput, accuracy and speed. In conclusion, MALDI-TOF MS is an excellent method for differentiating NTHi and H. haemolyticus. This method can be recommended for use in appropriately equipped laboratories. PMID:23457514
Food Composition Database Format and Structure: A User Focused Approach
Clancy, Annabel K.; Woods, Kaitlyn; McMahon, Anne; Probst, Yasmine
2015-01-01
This study aimed to investigate the needs of Australian food composition database user’s regarding database format and relate this to the format of databases available globally. Three semi structured synchronous online focus groups (M = 3, F = 11) and n = 6 female key informant interviews were recorded. Beliefs surrounding the use, training, understanding, benefits and limitations of food composition data and databases were explored. Verbatim transcriptions underwent preliminary coding followed by thematic analysis with NVivo qualitative analysis software to extract the final themes. Schematic analysis was applied to the final themes related to database format. Desktop analysis also examined the format of six key globally available databases. 24 dominant themes were established, of which five related to format; database use, food classification, framework, accessibility and availability, and data derivation. Desktop analysis revealed that food classification systems varied considerably between databases. Microsoft Excel was a common file format used in all databases, and available software varied between countries. User’s also recognised that food composition databases format should ideally be designed specifically for the intended use, have a user-friendly food classification system, incorporate accurate data with clear explanation of data derivation and feature user input. However, such databases are limited by data availability and resources. Further exploration of data sharing options should be considered. Furthermore, user’s understanding of food composition data and databases limitations is inherent to the correct application of non-specific databases. Therefore, further exploration of user FCDB training should also be considered. PMID:26554836
Database citation in full text biomedical articles.
Kafkas, Şenay; Kim, Jee-Hyub; McEntyre, Johanna R
2013-01-01
Molecular biology and literature databases represent essential infrastructure for life science research. Effective integration of these data resources requires that there are structured cross-references at the level of individual articles and biological records. Here, we describe the current patterns of how database entries are cited in research articles, based on analysis of the full text Open Access articles available from Europe PMC. Focusing on citation of entries in the European Nucleotide Archive (ENA), UniProt and Protein Data Bank, Europe (PDBe), we demonstrate that text mining doubles the number of structured annotations of database record citations supplied in journal articles by publishers. Many thousands of new literature-database relationships are found by text mining, since these relationships are also not present in the set of articles cited by database records. We recommend that structured annotation of database records in articles is extended to other databases, such as ArrayExpress and Pfam, entries from which are also cited widely in the literature. The very high precision and high-throughput of this text-mining pipeline makes this activity possible both accurately and at low cost, which will allow the development of new integrated data services.
Database Citation in Full Text Biomedical Articles
Kafkas, Şenay; Kim, Jee-Hyub; McEntyre, Johanna R.
2013-01-01
Molecular biology and literature databases represent essential infrastructure for life science research. Effective integration of these data resources requires that there are structured cross-references at the level of individual articles and biological records. Here, we describe the current patterns of how database entries are cited in research articles, based on analysis of the full text Open Access articles available from Europe PMC. Focusing on citation of entries in the European Nucleotide Archive (ENA), UniProt and Protein Data Bank, Europe (PDBe), we demonstrate that text mining doubles the number of structured annotations of database record citations supplied in journal articles by publishers. Many thousands of new literature-database relationships are found by text mining, since these relationships are also not present in the set of articles cited by database records. We recommend that structured annotation of database records in articles is extended to other databases, such as ArrayExpress and Pfam, entries from which are also cited widely in the literature. The very high precision and high-throughput of this text-mining pipeline makes this activity possible both accurately and at low cost, which will allow the development of new integrated data services. PMID:23734176
NASA Astrophysics Data System (ADS)
Ban, Yunyun; Chen, Tianqin; Yan, Jun; Lei, Tingwu
2017-04-01
The measurement of sediment concentration in water is of great importance in soil erosion research and soil and water loss monitoring systems. The traditional weighing method has long been the foundation of all the other measuring methods and instrument calibration. The development of a new method to replace the traditional oven-drying method is of interest in research and practice for the quick and efficient measurement of sediment concentration, especially field measurements. A new method is advanced in this study for accurately measuring the sediment concentration based on the accurate measurement of the mass of the sediment-water mixture in the confined constant volume container (CVC). A sediment-laden water sample is put into the CVC to determine its mass before the CVC is filled with water and weighed again for the total mass of the water and sediments in the container. The known volume of the CVC, the mass of sediment-laden water, and sediment particle density are used to calculate the mass of water, which is replaced by sediments, therefore sediment concentration of the sample is calculated. The influence of water temperature was corrected by measuring water density to determine the temperature of water before measurements were conducted. The CVC was used to eliminate the surface tension effect so as to obtain the accurate volume of water and sediment mixture. Experimental results showed that the method was capable of measuring the sediment concentration from 0.5 up to 1200 kg m-3. A good liner relationship existed between the designed and measured sediment concentrations with all the coefficients of determination greater than 0.999 and the averaged relative error less than 0.2%. All of these seem to indicate that the new method is capable of measuring a full range of sediment concentration above 0.5 kg m-3 to replace the traditional oven-drying method as a standard method for evaluating and calibrating other methods.
NASA Astrophysics Data System (ADS)
Köchy, M.; Hiederer, R.; Freibauer, A.
2015-04-01
The global soil organic carbon (SOC) mass is relevant for the carbon cycle budget and thus atmospheric carbon concentrations. We review current estimates of SOC stocks and mass (stock × area) in wetlands, permafrost and tropical regions and the world in the upper 1 m of soil. The Harmonized World Soil Database (HWSD) v.1.2 provides one of the most recent and coherent global data sets of SOC, giving a total mass of 2476 Pg when using the original values for bulk density. Adjusting the HWSD's bulk density (BD) of soil high in organic carbon results in a mass of 1230 Pg, and additionally setting the BD of Histosols to 0.1 g cm-3 (typical of peat soils), results in a mass of 1062 Pg. The uncertainty in BD of Histosols alone introduces a range of -56 to +180 Pg C into the estimate of global SOC mass in the top 1 m, larger than estimates of global soil respiration. We report the spatial distribution of SOC stocks per 0.5 arcminutes; the areal masses of SOC; and the quantiles of SOC stocks by continents, wetland types, and permafrost types. Depending on the definition of "wetland", wetland soils contain between 82 and 158 Pg SOC. With more detailed estimates for permafrost from the Northern Circumpolar Soil Carbon Database (496 Pg SOC) and tropical peatland carbon incorporated, global soils contain 1325 Pg SOC in the upper 1 m, including 421 Pg in tropical soils, whereof 40 Pg occurs in tropical wetlands. Global SOC amounts to just under 3000 Pg when estimates for deeper soil layers are included. Variability in estimates is due to variation in definitions of soil units, differences in soil property databases, scarcity of information about soil carbon at depths > 1 m in peatlands, and variation in definitions of "peatland".
Energy balance and mass conservation in reduced order models of fluid flows
NASA Astrophysics Data System (ADS)
Mohebujjaman, Muhammad; Rebholz, Leo G.; Xie, Xuping; Iliescu, Traian
2017-10-01
In this paper, we investigate theoretically and computationally the conservation properties of reduced order models (ROMs) for fluid flows. Specifically, we investigate whether the ROMs satisfy the same (or similar) energy balance and mass conservation as those satisfied by the Navier-Stokes equations. All of our theoretical findings are illustrated and tested in numerical simulations of a 2D flow past a circular cylinder at a Reynolds number Re = 100. First, we investigate the ROM energy balance. We show that using the snapshot average for the centering trajectory (which is a popular treatment of nonhomogeneous boundary conditions in ROMs) yields an incorrect energy balance. Then, we propose a new approach, in which we replace the snapshot average with the Stokes extension. Theoretically, the Stokes extension produces an accurate energy balance. Numerically, the Stokes extension yields more accurate results than the standard snapshot average, especially for longer time intervals. Our second contribution centers around ROM mass conservation. We consider ROMs created using two types of finite elements: the standard Taylor-Hood (TH) element, which satisfies the mass conservation weakly, and the Scott-Vogelius (SV) element, which satisfies the mass conservation pointwise. Theoretically, the error estimates for the SV-ROM are sharper than those for the TH-ROM. Numerically, the SV-ROM yields significantly more accurate results, especially for coarser meshes and longer time intervals.
Scheduled Civil Aircraft Emission Inventories for 1999: Database Development and Analysis
NASA Technical Reports Server (NTRS)
Sutkus, Donald J., Jr.; Baughcum, Steven L.; DuBois, Douglas P.
2001-01-01
This report describes the development of a three-dimensional database of aircraft fuel burn and emissions (NO(x), CO, and hydrocarbons) for the scheduled commercial aircraft fleet for each month of 1999. Global totals of emissions and fuel burn for 1999 are compared to global totals from 1992 and 2015 databases. 1999 fuel burn, departure and distance totals for selected airlines are compared to data reported on DOT Form 41 to evaluate the accuracy of the calculations. DOT Form T-100 data were used to determine typical payloads for freighter aircraft and this information was used to model freighter aircraft more accurately by using more realistic payloads. Differences in the calculation methodology used to create the 1999 fuel burn and emissions database from the methodology used in previous work are described and evaluated.
FreeSolv: A database of experimental and calculated hydration free energies, with input files
Mobley, David L.; Guthrie, J. Peter
2014-01-01
This work provides a curated database of experimental and calculated hydration free energies for small neutral molecules in water, along with molecular structures, input files, references, and annotations. We call this the Free Solvation Database, or FreeSolv. Experimental values were taken from prior literature and will continue to be curated, with updated experimental references and data added as they become available. Calculated values are based on alchemical free energy calculations using molecular dynamics simulations. These used the GAFF small molecule force field in TIP3P water with AM1-BCC charges. Values were calculated with the GROMACS simulation package, with full details given in references cited within the database itself. This database builds in part on a previous, 504-molecule database containing similar information. However, additional curation of both experimental data and calculated values has been done here, and the total number of molecules is now up to 643. Additional information is now included in the database, such as SMILES strings, PubChem compound IDs, accurate reference DOIs, and others. One version of the database is provided in the Supporting Information of this article, but as ongoing updates are envisioned, the database is now versioned and hosted online. In addition to providing the database, this work describes its construction process. The database is available free-of-charge via http://www.escholarship.org/uc/item/6sd403pz. PMID:24928188