Science.gov

Sample records for accurately recording beam

  1. Beam Profile Monitor With Accurate Horizontal And Vertical Beam Profiles

    DOEpatents

    Havener, Charles C [Knoxville, TN; Al-Rejoub, Riad [Oak Ridge, TN

    2005-12-26

    A widely used scanner device that rotates a single helically shaped wire probe in and out of a particle beam at different beamline positions to give a pair of mutually perpendicular beam profiles is modified by the addition of a second wire probe. As a result, a pair of mutually perpendicular beam profiles is obtained at a first beamline position, and a second pair of mutually perpendicular beam profiles is obtained at a second beamline position. The simple modification not only provides more accurate beam profiles, but also provides a measurement of the beam divergence and quality in a single compact device.

  2. Accurate Method for Determining Adhesion of Cantilever Beams

    SciTech Connect

    Michalske, T.A.; de Boer, M.P.

    1999-01-08

    Using surface micromachined samples, we demonstrate the accurate measurement of cantilever beam adhesion by using test structures which are adhered over long attachment lengths. We show that this configuration has a deep energy well, such that a fracture equilibrium is easily reached. When compared to the commonly used method of determining the shortest attached beam, the present method is much less sensitive to variations in surface topography or to details of capillary drying.

  3. Accurate Position Sensing of Defocused Beams Using Simulated Beam Templates

    SciTech Connect

    Awwal, A; Candy, J; Haynam, C; Widmayer, C; Bliss, E; Burkhart, S

    2004-09-29

    In position detection using matched filtering one is faced with the challenge of determining the best position in the presence of distortions such as defocus and diffraction noise. This work evaluates the performance of simulated defocused images as the template against the real defocused beam. It was found that an amplitude modulated phase-only filter is better equipped to deal with real defocused images that suffer from diffraction noise effects resulting in a textured spot intensity pattern. It is shown that the there is a tradeoff of performance dependent upon the type and size of the defocused image. A novel automated system was developed that can automatically select the right template type and size. Results of this automation for real defocused images are presented.

  4. Device accurately measures and records low gas-flow rates

    NASA Technical Reports Server (NTRS)

    Branum, L. W.

    1966-01-01

    Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

  5. Pink-Beam, Highly-Accurate Compact Water Cooled Slits

    SciTech Connect

    Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard; Waterman, Dave; Caletka, Dave; Steadman, Paul; Dhesi, Sarnjeet

    2007-01-19

    Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Element Analysis of the system are presented.

  6. 36 CFR 1202.26 - Who will make sure that my record is accurate?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... RECORDS ADMINISTRATION GENERAL RULES REGULATIONS IMPLEMENTING THE PRIVACY ACT OF 1974 Collecting Information § 1202.26 Who will make sure that my record is accurate? The system manager ensures that...

  7. Do foraminifera accurately record seawater neodymium isotope composition?

    NASA Astrophysics Data System (ADS)

    Scrivner, Adam; Skinner, Luke; Vance, Derek

    2010-05-01

    Palaeoclimate studies involving the reconstruction of past Atlantic meridional overturning circulation increasingly employ isotopes of neodymium (Nd), measured on a variety of sample media (Frank, 2002). In the open ocean, Nd isotopes are a conservative tracer of water mass mixing and are unaffected by biological and low-temperature fractionation processes (Piepgras and Wasserburg, 1987; Lacan and Jeandel, 2005). For decades, benthic foraminifera have been widely utilised in stable isotope and geochemical studies, but have only recently begun to be exploited as a widely distributed, high-resolution Nd isotope archive (Klevenz et al., 2008), potentially circumventing the difficulties associated with other methods used to recover past deep-water Nd isotopes (Klevenz et al., 2008; Rutberg et al., 2000; Tachikawa et al., 2004). Thus far, a single pilot study (Klevenz et al., 2008) has indicated that core-top sedimentary benthic foraminifera record a Nd isotope composition in agreement with the nearest available bottom seawater data, and has suggested that this archive is potentially useful on both millennial and million-year timescales. Here we present seawater and proximal core-top foraminifer Nd isotope data for samples recovered during the 2008 "RETRO" cruise of the Marion Dufresne. The foraminifer samples comprise a depth-transect spanning 3000m of the water column in the Angola Basin and permit a direct comparison between high-resolution water column and core-top foraminiferal Nd isotope data. We use these data to assess the reliability of both planktonic and benthic foraminifera as recorders of water column neodymium isotope composition. Frank, M., 2002. Radiogenic isotopes: Tracers of past ocean circulation and erosional input, Rev. Geophys., 40 (1), 1001, doi:10.1029/2000RG000094. Klevenz, V., Vance, D., Schmidt, D.N., and Mezger, K., 2008. Neodymium isotopes in benthic foraminifera: Core-top systematics and a down-core record from the Neogene south Atlantic

  8. Accurate model of electron beam profiles with emittance effects for pierce guns

    NASA Astrophysics Data System (ADS)

    Zeng, Peng; Wang, Guangqiang; Wang, Jianguo; Wang, Dongyang; Li, Shuang

    2016-09-01

    Accurate prediction of electron beam profile is one of the key objectives of electron optics, and the basis for design of the practical electron gun. In this paper, an improved model describing electron beam in Pierce gun with both space charge effects and emittance effects is proposed. The theory developed by Cutler and Hines is still applied for the accelerating region of the Pierce gun, while the motion equations of the electron beams in the anode aperture and drift tunnel are improved by modifying electron optics theory with emittance. As a result, a more universal and accurate formula of the focal length of the lens for the electron beam with both effects is derived for the anode aperture with finite dimension, and a modified universal spread curve considering beam emittance is introduced in drift tunnel region. Based on these improved motion equations of the electron beam, beam profiles with space charge effects and emittance effects can be theoretically predicted, which are subsequently approved to agree well with the experimentally measured ones. The developed model here is helpful to design more applicable Pierce guns at high frequencies.

  9. [Accurate 3D free-form registration between fan-beam CT and cone-beam CT].

    PubMed

    Liang, Yueqiang; Xu, Hongbing; Li, Baosheng; Li, Hongsheng; Yang, Fujun

    2012-06-01

    Because the X-ray scatters, the CT numbers in cone-beam CT cannot exactly correspond to the electron densities. This, therefore, results in registration error when the intensity-based registration algorithm is used to register planning fan-beam CT and cone-beam CT. In order to reduce the registration error, we have developed an accurate gradient-based registration algorithm. The gradient-based deformable registration problem is described as a minimization of energy functional. Through the calculus of variations and Gauss-Seidel finite difference method, we derived the iterative formula of the deformable registration. The algorithm was implemented by GPU through OpenCL framework, with which the registration time was greatly reduced. Our experimental results showed that the proposed gradient-based registration algorithm could register more accurately the clinical cone-beam CT and fan-beam CT images compared with the intensity-based algorithm. The GPU-accelerated algorithm meets the real-time requirement in the online adaptive radiotherapy.

  10. Are In-Bed Electronic Weights Recorded in the Medical Record Accurate?

    PubMed

    Gerl, Heather; Miko, Alexandra; Nelson, Mandy; Godaire, Lori

    2016-01-01

    This study found large discrepancies between in-bed weights recorded in the medical record and carefully obtained standing weights with a calibrated, electronic bedside scale. This discrepancy appears to be related to inadequate bed calibration before patient admission and having excessive linen, clothing, and/or equipment on the bed during weighing by caregivers.

  11. Evaluating the capability of time-of-flight cameras for accurately imaging a cyclically loaded beam

    NASA Astrophysics Data System (ADS)

    Lahamy, Hervé; Lichti, Derek; El-Badry, Mamdouh; Qi, Xiaojuan; Detchev, Ivan; Steward, Jeremy; Moravvej, Mohammad

    2015-05-01

    Time-of-flight cameras are used for diverse applications ranging from human-machine interfaces and gaming to robotics and earth topography. This paper aims at evaluating the capability of the Mesa Imaging SR4000 and the Microsoft Kinect 2.0 time-of-flight cameras for accurately imaging the top surface of a concrete beam subjected to fatigue loading in laboratory conditions. Whereas previous work has demonstrated the success of such sensors for measuring the response at point locations, the aim here is to measure the entire beam surface in support of the overall objective of evaluating the effectiveness of concrete beam reinforcement with steel fibre reinforced polymer sheets. After applying corrections for lens distortions to the data and differencing images over time to remove systematic errors due to internal scattering, the periodic deflections experienced by the beam have been estimated for the entire top surface of the beam and at witness plates attached. The results have been assessed by comparison with measurements from highly-accurate laser displacement transducers. This study concludes that both the Microsoft Kinect 2.0 and the Mesa Imaging SR4000s are capable of sensing a moving surface with sub-millimeter accuracy once the image distortions have been modeled and removed.

  12. Using transient waveform recorders to measure and store beam parameters

    SciTech Connect

    Stege, R.E. Jr.; Jobe, R.K.; Ross, M.

    1993-05-01

    Transient waveform digitizers are used to measure the tunes in the Stanford Liner Collider (SLC) damping rings. Since the beam injection and extraction from these rings occurs at a high rate (120 Hz) and because of the stringent extracted beam stability requirements, simpler asynchronous resonant excitation spectrum analyzer measurements are not possible. The beam position monitor signals are processed, digitized, and a Fast Fourier Transform (FFT) is applied to find the tunes. The coherent beam motion at injection, even though it damps quickly, is large enough to provide a strong tune signal. Recently, this technique has also been applied to several longitudinal signals. The results from these monitors are recorded at six-minute intervals in the SLC control system history buffers. This paper will describe the hardware setup and the software used to process the data, and will present some of the results.

  13. MASS MEASUREMENTS BY AN ACCURATE AND SENSITIVE SELECTED ION RECORDING TECHNIQUE

    EPA Science Inventory

    Trace-level components of mixtures were successfully identified or confirmed by mass spectrometric accurate mass measurements, made at high resolution with selected ion recording, using GC and LC sample introduction. Measurements were made at 20 000 or 10 000 resolution, respecti...

  14. Recording PEP2 Ring Beam Losses at SLAC

    SciTech Connect

    Zelazny, M.; Gromme, T.; Himel, T.; Hendrickson, L.; Krauter, K.; /SLAC

    2005-09-30

    The PEP2 (e+)(e-) storage rings contain many complex interrelated systems. When the beam aborts, examining a record of the orbit from the time just before the abort can help identify the root cause. At the Stanford Linear Accelerator Center (SLAC) a system has been developed to continuously record beam orbits from Beam Position Monitors (BPMS) into a circular buffer. When the beam is aborted the buffers are frozen and their contents are stored for later analysis. BPM orbits are saved on a turn by turn basis for 2800 turns in both the high energy ring (HER) and the low energy ring (LER). Each BPM Processor (BPMP) can either monitor the HER or the LER, but not both as the readout of the two rings is multiplexed into a single readout channel. Tools exist as part of the SLAC Control Program (SCP) to collect, display, and save the data. A physicist or operator can choose a few BPMS in which to view all 2800 turns to identify the turn in which the beam went awry; then ask for that specific orbit from all of the BPMS in the storage ring to determine the root cause of the abort.

  15. Accurately modeling Gaussian beam propagation in the context of Monte Carlo techniques

    NASA Astrophysics Data System (ADS)

    Hokr, Brett H.; Winblad, Aidan; Bixler, Joel N.; Elpers, Gabriel; Zollars, Byron; Scully, Marlan O.; Yakovlev, Vladislav V.; Thomas, Robert J.

    2016-03-01

    Monte Carlo simulations are widely considered to be the gold standard for studying the propagation of light in turbid media. However, traditional Monte Carlo methods fail to account for diffraction because they treat light as a particle. This results in converging beams focusing to a point instead of a diffraction limited spot, greatly effecting the accuracy of Monte Carlo simulations near the focal plane. Here, we present a technique capable of simulating a focusing beam in accordance to the rules of Gaussian optics, resulting in a diffraction limited focal spot. This technique can be easily implemented into any traditional Monte Carlo simulation allowing existing models to be converted to include accurate focusing geometries with minimal effort. We will present results for a focusing beam in a layered tissue model, demonstrating that for different scenarios the region of highest intensity, thus the greatest heating, can change from the surface to the focus. The ability to simulate accurate focusing geometries will greatly enhance the usefulness of Monte Carlo for countless applications, including studying laser tissue interactions in medical applications and light propagation through turbid media.

  16. Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy

    SciTech Connect

    Ding, George X.; Duggan, Dennis M.; Coffey, Charles W.

    2008-03-15

    The increased utilization of x-ray imaging in image-guided radiotherapy has dramatically improved the radiation treatment and the lives of cancer patients. Daily imaging procedures, such as cone-beam computed tomography (CBCT), for patient setup may significantly increase the dose to the patient's normal tissues. This study investigates the dosimetry from a kilovoltage (kV) CBCT for real patient geometries. Monte Carlo simulations were used to study the kV beams from a Varian on-board imager integrated into the Trilogy accelerator. The Monte Carlo calculated results were benchmarked against measurements and good agreement was obtained. The authors developed a novel method to calibrate Monte Carlo simulated beams with measurements using an ionization chamber in which the air-kerma calibration factors are obtained from an Accredited Dosimetry Calibration Laboratory. The authors have introduced a new Monte Carlo calibration factor, f{sub MCcal}, which is determined from the calibration procedure. The accuracy of the new method was validated by experiment. When a Monte Carlo simulated beam has been calibrated, the simulated beam can be used to accurately predict absolute dose distributions in the irradiated media. Using this method the authors calculated dose distributions to patient anatomies from a typical CBCT acquisition for different treatment sites, such as head and neck, lung, and pelvis. Their results have shown that, from a typical head and neck CBCT, doses to soft tissues, such as eye, spinal cord, and brain can be up to 8, 6, and 5 cGy, respectively. The dose to the bone, due to the photoelectric effect, can be as much as 25 cGy, about three times the dose to the soft tissue. The study provides detailed information on the additional doses to the normal tissues of a patient from a typical kV CBCT acquisition. The methodology of the Monte Carlo beam calibration developed and introduced in this study allows the user to calculate both relative and absolute

  17. Ocean Lidar Measurements of Beam Attenuation and a Roadmap to Accurate Phytoplankton Biomass Estimates

    NASA Astrophysics Data System (ADS)

    Hu, Yongxiang; Behrenfeld, Mike; Hostetler, Chris; Pelon, Jacques; Trepte, Charles; Hair, John; Slade, Wayne; Cetinic, Ivona; Vaughan, Mark; Lu, Xiaomei; Zhai, Pengwang; Weimer, Carl; Winker, David; Verhappen, Carolus C.; Butler, Carolyn; Liu, Zhaoyan; Hunt, Bill; Omar, Ali; Rodier, Sharon; Lifermann, Anne; Josset, Damien; Hou, Weilin; MacDonnell, David; Rhew, Ray

    2016-06-01

    Beam attenuation coefficient, c, provides an important optical index of plankton standing stocks, such as phytoplankton biomass and total particulate carbon concentration. Unfortunately, c has proven difficult to quantify through remote sensing. Here, we introduce an innovative approach for estimating c using lidar depolarization measurements and diffuse attenuation coefficients from ocean color products or lidar measurements of Brillouin scattering. The new approach is based on a theoretical formula established from Monte Carlo simulations that links the depolarization ratio of sea water to the ratio of diffuse attenuation Kd and beam attenuation C (i.e., a multiple scattering factor). On July 17, 2014, the CALIPSO satellite was tilted 30° off-nadir for one nighttime orbit in order to minimize ocean surface backscatter and demonstrate the lidar ocean subsurface measurement concept from space. Depolarization ratios of ocean subsurface backscatter are measured accurately. Beam attenuation coefficients computed from the depolarization ratio measurements compare well with empirical estimates from ocean color measurements. We further verify the beam attenuation coefficient retrievals using aircraft-based high spectral resolution lidar (HSRL) data that are collocated with in-water optical measurements.

  18. Automatic identification and accurate temporal detection of inhalations in asthma inhaler recordings.

    PubMed

    Holmes, Martin S; Le Menn, Marine; D'Arcy, Shona; Rapcan, Viliam; MacHale, Elaine; Costello, Richard W; Reilly, Richard B

    2012-01-01

    Asthma is chronic airways disease characterized by recurrent attacks of breathlessness and wheezing. Adherence to medication regimes is a common failing for asthmatic patients and there exists a requirement to monitor such patients' adherence. The detection of inhalations from recordings of inhaler use can provide empirical evidence about patients' adherence to their asthma medication regime. Manually listening to recordings of inhaler use is a tedious and time consuming process and thus an algorithm which can automatically and accurately carry out this task would be of great value. This study employs a recording device attached to a commonly used dry powder inhaler to record the acoustic signals of patients taking their prescribed medication. An algorithm was developed to automatically detect and accurately demarcate inhalations from the acoustic signals. This algorithm was tested on a dataset of 255 separate recordings of inhaler use in real world environments. The dataset was obtained from 12 asthma outpatients who attended a respiratory clinic over a three month period. Evaluation of the algorithm on this dataset achieved sensitivity of 95%, specificity of 94% and an accuracy of 89% in detecting inhalations compared to manual inhalation detection.

  19. Electron beam tomography of magnetic recording head fields

    NASA Astrophysics Data System (ADS)

    Ferrier, R. P.; Liu, Y.; Martin, J. L.; Arnoldussen, T. C.

    1995-09-01

    The quantitative evaluation of the 3D form of the magnetic field from a thin film recording head has been achieved by electron beam tomography. The data sets for tomographic reconstruction were obtained using the differential phase contrast mode of Lorentz electron microscopy applied in a 200 kV (scanning) transmission instrument. The high accelerating voltage and a novel method of mounting the head in the microscope offer advantages over previous experiments. The two reconstruction algorithms, which have been used previously, have been implemented and the results of their application are compared for theoretical data derived from a model head field and for data obtained experimentally from a production recording head.

  20. Clarification of Employer's Continuing Obligation To Make and Maintain an Accurate Record of Each Recordable Injury and Illness. Final rule.

    PubMed

    2016-12-19

    OSHA is amending its recordkeeping regulations to clarify that the duty to make and maintain accurate records of work-related injuries and illnesses is an ongoing obligation. The duty to record an injury or illness continues for as long as the employer must keep records of the recordable injury or illness; the duty does not expire just because the employer fails to create the necessary records when first required to do so. The amendments consist of revisions to the titles of some existing sections and subparts and changes to the text of some existing provisions. The amendments add no new compliance obligations and do not require employers to make records of any injuries or illnesses for which records are not currently required to be made. The amendments in this rule are adopted in response to a decision of the United States Court of Appeals for the District of Columbia Circuit. In that case, a majority held that the Occupational Safety and Health Act does not permit OSHA to impose a continuing recordkeeping obligation on employers. One judge filed a concurring opinion disagreeing with this reading of the statute, but finding that the text of OSHA's recordkeeping regulations did not impose continuing recordkeeping duties. OSHA disagrees with the majority's reading of the law, but agrees that its recordkeeping regulations were not clear with respect to the continuing nature of employers' recordkeeping obligations. This final rule is designed to clarify the regulations in advance of possible future federal court litigation that could further develop the law on the statutory issues addressed in the D.C. Circuit's decision.

  1. A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections

    PubMed Central

    Jia, Xun; Yan, Hao; Cerviño, Laura; Folkerts, Michael; Jiang, Steve B.

    2012-01-01

    Purpose: Simulation of x-ray projection images plays an important role in cone beam CT (CBCT) related research projects, such as the design of reconstruction algorithms or scanners. A projection image contains primary signal, scatter signal, and noise. It is computationally demanding to perform accurate and realistic computations for all of these components. In this work, the authors develop a package on graphics processing unit (GPU), called gDRR, for the accurate and efficient computations of x-ray projection images in CBCT under clinically realistic conditions. Methods: The primary signal is computed by a trilinear ray-tracing algorithm. A Monte Carlo (MC) simulation is then performed, yielding the primary signal and the scatter signal, both with noise. A denoising process specifically designed for Poisson noise removal is applied to obtain a smooth scatter signal. The noise component is then obtained by combining the difference between the MC primary and the ray-tracing primary signals, and the difference between the MC simulated scatter and the denoised scatter signals. Finally, a calibration step converts the calculated noise signal into a realistic one by scaling its amplitude according to a specified mAs level. The computations of gDRR include a number of realistic features, e.g., a bowtie filter, a polyenergetic spectrum, and detector response. The implementation is fine-tuned for a GPU platform to yield high computational efficiency. Results: For a typical CBCT projection with a polyenergetic spectrum, the calculation time for the primary signal using the ray-tracing algorithms is 1.2–2.3 s, while the MC simulations take 28.1–95.3 s, depending on the voxel size. Computation time for all other steps is negligible. The ray-tracing primary signal matches well with the primary part of the MC simulation result. The MC simulated scatter signal using gDRR is in agreement with EGSnrc results with a relative difference of 3.8%. A noise calibration process is

  2. Recording/reproduction simulation of holographic memory using three-dimensional beam propagation method

    NASA Astrophysics Data System (ADS)

    Ohori, Tomohiro; Yoshida, Shuhei; Yamamoto, Manabu

    2010-05-01

    The rapid progress in computer performance and widespread use of broadband networks has facilitated the transmission of huge quantities of digital information, thus increasing the need for high-speed, large-capacity storage devices and leading to studies on holographic data storage (HDS). Compared with laser disks where the recording density is limited by optical diffraction, HDS provides ultrahigh capacity with multiplex recording and high-speed transfer greater than 1 Gbps; it has excellent potential for optical memory systems of the future [1]. To develop HDS, a design theory for element technologies such as signal processing, recording materials and optical systems is required. Therefore, this study examines technology for simulating the recording and reproduction for HDS. In simulations thus far, the medium for the recording process has usually been approximated as laminated layers of holographic thin films. This method is suitable for systematic evaluation because the computational cost is low and it allows simulation in the true form of data, that is, in two-dimensional digital data patterns. However, it is difficult to accurately examine the influence of film thickness with a two-dimensional lamination simulation. Therefore, in this study, a technique for analyzing thick-film holograms is examined using the beam propagation method. The results of a two-dimensional simulation assuming laminated, holographic thin films and a three-dimensional simulation using the beam propagation method are compared for cases where the medium need not be treated as a thick film.

  3. Production of pure quasi-monochromatic 11C beams for accurate radiation therapy and dose delivery verification

    NASA Astrophysics Data System (ADS)

    Lazzeroni, Marta; Brahme, Anders

    2015-09-01

    In the present study we develop a new technique for the production of clean quasi-monochromatic 11C positron emitter beams for accurate radiation therapy and PET-CT dose delivery imaging and treatment verification. The 11C ion beam is produced by projectile fragmentation using a primary 12C ion beam. The practical elimination of the energy spread of the secondary 11C fragments and other beam contaminating fragments is described. Monte Carlo calculation with the SHIELD-HIT10+ code and analytical methods for the transport of the ions in matter are used in the analysis. Production yields, as well as energy, velocity and magnetic rigidity distributions of the fragments generated in a cylindrical target are scored as a function of the depth within 1 cm thick slices for an optimal target consisting of a fixed 20 cm section of liquid hydrogen followed by a variable thickness section of polyethylene. The wide energy and magnetic rigidity spread of the 11C ion beam can be reduced to values around 1% by using a variable monochromatizing wedge-shaped degrader in the beam line. Finally, magnetic rigidity and particle species selection, as well as discrimination of the particle velocity through a combined Time of Flight and Radio Frequency-driven Velocity filter purify the beam from similar magnetic rigidity contaminating fragments (mainly 7Be and 3He fragments). A beam purity of about 99% is expected by the combined method.

  4. Highly Accurate Beam Torsion Solutions Using the p-Version Finite Element Method

    NASA Technical Reports Server (NTRS)

    Smith, James P.

    1996-01-01

    A new treatment of the classical beam torsion boundary value problem is applied. Using the p-version finite element method with shape functions based on Legendre polynomials, torsion solutions for generic cross-sections comprised of isotropic materials are developed. Element shape functions for quadrilateral and triangular elements are discussed, and numerical examples are provided.

  5. Beam rider for an Articulated Robot Manipulator (ARM) accurate positioning of long flexible manipulators

    NASA Technical Reports Server (NTRS)

    Malachowski, M. J.

    1990-01-01

    Laser beam positioning and beam rider modules were incorporated into the long hollow flexible segment of an articulated robot manipulator (ARM). Using a single laser beam, the system determined the position of the distal ARM endtip, with millimetric precision, in six degrees of freedom, at distances of up to 10 meters. Preliminary designs, using space rated technology for the critical systems, of a two segmented physical ARM, with a single and a dual degree of freedom articulation, were developed, prototyped, and tested. To control the positioning of the physical ARM, an indirect adaptive controller, which used the mismatch between the position of the laser beam under static and dynamic conditions, was devised. To predict the behavior of the system and test the concept, a computer simulation model was constructed. A hierarchical artificially intelligent real time ADA operating system program structure was created. The software was designed for implementation on a dedicated VME bus based Intel 80386 administered parallel processing multi-tasking computer system.

  6. Ultrafast Optical Beam Deflection in a Planar Waveguide for High Dynamic Range Recording at Picosecond Resolution

    SciTech Connect

    Sarantos, C H; Heebner, J E

    2008-07-02

    We report the latest performance of an ultrafast, all-optical beam deflector based on a prism array imprinted in a planar waveguide. The deflector enables single-shot, high dynamic range optical recording with picosecond resolution.

  7. Lake sedimentary DNA accurately records 20(th) Century introductions of exotic conifers in Scotland.

    PubMed

    Sjögren, Per; Edwards, Mary E; Gielly, Ludovic; Langdon, Catherine T; Croudace, Ian W; Merkel, Marie Kristine Føreid; Fonville, Thierry; Alsos, Inger Greve

    2017-01-01

    Sedimentary DNA (sedDNA) has recently emerged as a new proxy for reconstructing past vegetation, but its taphonomy, source area and representation biases need better assessment. We investigated how sedDNA in recent sediments of two small Scottish lakes reflects a major vegetation change, using well-documented 20(th) Century plantations of exotic conifers as an experimental system. We used next-generation sequencing to barcode sedDNA retrieved from subrecent lake sediments. For comparison, pollen was analysed from the same samples. The sedDNA record contains 73 taxa (mainly genus or species), all but one of which are present in the study area. Pollen and sedDNA shared 35% of taxa, which partly reflects a difference in source area. More aquatic taxa were recorded in sedDNA, whereas taxa assumed to be of regional rather than local origin were recorded only as pollen. The chronology of the sediments and planting records are well aligned, and sedDNA of exotic conifers appears in high quantities with the establishment of plantations around the lakes. SedDNA recorded other changes in local vegetation that accompanied afforestation. There were no signs of DNA leaching in the sediments or DNA originating from pollen.

  8. Accurate and Fast Localization of Prostate for External Beam Radiation Therapy

    DTIC Science & Technology

    2009-03-01

    reconstruction for CBCT using edge- preserving prior”, Medical Physics, vol. 36, pp. 252-260, 2009 3. L. Zhu, J. Wang, and L. Xing, “Noise suppression...1. J. Wang, A. Chai, L. Xing, “Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT ”, poster...presentation in 2009 SPIE Medical Imaging conference, Orlando, FL 2. J. Wang, T. Li, and L. Xing, “Low-dose CBCT Imaging for External Beam Radiotherapy

  9. Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis.

    PubMed

    Bespamyatnov, Igor O; Rowan, William L; Granetz, Robert S

    2008-10-01

    Charge exchange recombination spectroscopy on Alcator C-Mod relies on the use of the diagnostic neutral beam injector as a source of neutral particles which penetrate deep into the plasma. It employs the emission resulting from the interaction of the beam atoms with fully ionized impurity ions. To interpret the emission from a given point in the plasma as the density of emitting impurity ions, the density of beam atoms must be known. Here, an analysis of beam propagation is described which yields the beam density profile throughout the beam trajectory from the neutral beam injector to the core of the plasma. The analysis includes the effects of beam formation, attenuation in the neutral gas surrounding the plasma, and attenuation in the plasma. In the course of this work, a numerical simulation and an analytical approximation for beam divergence are developed. The description is made sufficiently compact to yield accurate results in a time consistent with between-shot analysis.

  10. Accurate determination of electronic transport properties of silicon wafers by nonlinear photocarrier radiometry with multiple pump beam sizes

    SciTech Connect

    Wang, Qian; Li, Bincheng

    2015-12-07

    In this paper, photocarrier radiometry (PCR) technique with multiple pump beam sizes is employed to determine simultaneously the electronic transport parameters (the carrier lifetime, the carrier diffusion coefficient, and the front surface recombination velocity) of silicon wafers. By employing the multiple pump beam sizes, the influence of instrumental frequency response on the multi-parameter estimation is totally eliminated. A nonlinear PCR model is developed to interpret the PCR signal. Theoretical simulations are performed to investigate the uncertainties of the estimated parameter values by investigating the dependence of a mean square variance on the corresponding transport parameters and compared to that obtained by the conventional frequency-scan method, in which only the frequency dependences of the PCR amplitude and phase are recorded at single pump beam size. Simulation results show that the proposed multiple-pump-beam-size method can improve significantly the accuracy of the determination of the electronic transport parameters. Comparative experiments with a p-type silicon wafer with resistivity 0.1–0.2 Ω·cm are performed, and the electronic transport properties are determined simultaneously. The estimated uncertainties of the carrier lifetime, diffusion coefficient, and front surface recombination velocity are approximately ±10.7%, ±8.6%, and ±35.4% by the proposed multiple-pump-beam-size method, which is much improved than ±15.9%, ±29.1%, and >±50% by the conventional frequency-scan method. The transport parameters determined by the proposed multiple-pump-beam-size PCR method are in good agreement with that obtained by a steady-state PCR imaging technique.

  11. Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners.

    PubMed

    Ji, Changguo; van der Have, Frans; Gratama van Andel, Hugo; Ramakers, Ruud; Beekman, Freek

    2010-01-01

    Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers during animal scanning. Methods. Transferable animal beds were developed with an accurate mounting interface. Simple calibration phantoms make it possible to obtain both the spatial transformation matrix for stitching multiple CT scans of different parts of the animal and to register SPECT and CT. The spatial transformation for image coregistration is calculated once using Horn's matching algorithm. Animal images can then be coregistered without using markers. Results. For mouse-sized objects, average coregistration errors between SPECT and CT in X, Y, and Z directions are within 0.04 mm, 0.10 mm, and 0.19 mm, respectively. For rat-sized objects, these numbers are 0.22 mm, 0.14 mm, and 0.28 mm. Average 3D coregistration errors were within 0.24 mm and 0.42 mm for mouse and rat imaging, respectively. Conclusion. Extending the field-of-view of cone-beam CT by stitching is improved by prior registration of the CT volumes. The accuracy of registration between SPECT and CT is typically better than the image resolution of current ultra-high-resolution SPECT.

  12. An accurate heart beat detection method in the EKG recorded in fMRI system.

    PubMed

    Oh, Sung Suk; Chung, Jun-Young; Yoon, Hyo Woon; Park, HyunWook

    2007-01-01

    The simultaneous recording of functional magnetic resonance imaging (fMRI) and electroencephalogram (EEG) provides an efficient signal for the high spatiotemporal brain mapping because each modality provides complementary information. The peak detection in the EEG signal measured in the MR scanner is necessary for removal of the ballistocardiac artifact. Especially, it would be affected by the quality of the EKG signal and the variation of the heart beat rate. Therefore, we propose the peak detection method using a K-teager energy operator (K-TEO) as well as further refinement processes in order to detect precise peaks. We applied this technique to the analysis of simulation waves with random noise and abrupt heat beat changes.

  13. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

    SciTech Connect

    Yan, Hao; Folkerts, Michael; Jiang, Steve B. E-mail: steve.jiang@UTSouthwestern.edu; Jia, Xun E-mail: steve.jiang@UTSouthwestern.edu; Zhen, Xin; Li, Yongbao; Pan, Tinsu; Cervino, Laura

    2014-07-15

    Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase

  14. “Stepping Up” Activity Poststroke: Ankle-Positioned Accelerometer Can Accurately Record Steps During Slow Walking

    PubMed Central

    Klassen, Tara D.; Simpson, Lisa A.; Lim, Shannon B.; Louie, Dennis R.; Parappilly, Beena; Sakakibara, Brodie M.; Zbogar, Dominik

    2016-01-01

    Background As physical activity in people poststroke is low, devices that monitor and provide feedback of walking activity provide motivation to engage in exercise and may assist rehabilitation professionals in auditing walking activity. However, most feedback devices are not accurate at slow walking speeds. Objective This study assessed the accuracy of one accelerometer to measure walking steps of community-dwelling individuals poststroke. Design This was a cross-sectional study. Methods Two accelerometers were positioned on the nonparetic waist and ankle of participants (N=43), and walking steps from these devices were recorded at 7 speeds (0.3–0.9 m/s) and compared with video recordings (gold standard). Results When positioned at the waist, the accelerometer had more than 10% error at all speeds, except 0.8 and 0.9 m/s, and numerous participants recorded zero steps at 0.3 to 0.5 m/s. The device had 10% or less error when positioned at the ankle for all speeds between 0.4 and 0.9 m/s. Limitations Some participants were unable to complete the faster walking speeds due to their walking impairments and inability to maintain the requested walking speed. Conclusions Although not recommended by the manufacturer, positioning the accelerometer at the ankle (compared with the waist) may fill a long-standing need for a readily available device that provides accurate feedback for the altered and slow walking patterns that occur with stroke. PMID:26251478

  15. Sustained accurate recording of intracellular acidification in living tissues with a photo-controllable bioluminescent protein.

    PubMed

    Hattori, Mitsuru; Haga, Sanae; Takakura, Hideo; Ozaki, Michitaka; Ozawa, Takeaki

    2013-06-04

    Regulation of an intracellular acidic environment plays a pivotal role in biological processes and functions. However, spatiotemporal analysis of the acidification in complex tissues of living subjects persists as an important challenge. We developed a photo-inactivatable bioluminescent indicator, based on a combination of luciferase-fragment complementation and a photoreaction of a light, oxygen, and voltage domain from Avena sativa Phototropin1 (LOV2), to visualize temporally dynamic acidification in living tissue samples. Bioluminescence of the indicator diminished upon light irradiation and it recovered gradually in the dark state thereafter. The recovery rate was remarkably sensitive to pH changes but unsusceptible to fluctuation of luciferin or ATP concentrations. Bioluminescence imaging, taken as an index of the recovery rates, enabled long-time recording of acidification in apoptotic and autophagous processes in a cell population and an ischemic condition in living mice. This technology using the indicator is widely applicable to sense organelle-specific acidic changes in target biological tissues.

  16. Sustained accurate recording of intracellular acidification in living tissues with a photo-controllable bioluminescent protein

    PubMed Central

    Hattori, Mitsuru; Haga, Sanae; Takakura, Hideo; Ozaki, Michitaka; Ozawa, Takeaki

    2013-01-01

    Regulation of an intracellular acidic environment plays a pivotal role in biological processes and functions. However, spatiotemporal analysis of the acidification in complex tissues of living subjects persists as an important challenge. We developed a photo-inactivatable bioluminescent indicator, based on a combination of luciferase-fragment complementation and a photoreaction of a light, oxygen, and voltage domain from Avena sativa Phototropin1 (LOV2), to visualize temporally dynamic acidification in living tissue samples. Bioluminescence of the indicator diminished upon light irradiation and it recovered gradually in the dark state thereafter. The recovery rate was remarkably sensitive to pH changes but unsusceptible to fluctuation of luciferin or ATP concentrations. Bioluminescence imaging, taken as an index of the recovery rates, enabled long-time recording of acidification in apoptotic and autophagous processes in a cell population and an ischemic condition in living mice. This technology using the indicator is widely applicable to sense organelle-specific acidic changes in target biological tissues. PMID:23690604

  17. A fast experimental beam hardening correction method for accurate bone mineral measurements in 3D μCT imaging system.

    PubMed

    Koubar, Khodor; Bekaert, Virgile; Brasse, David; Laquerriere, Patrice

    2015-06-01

    Bone mineral density plays an important role in the determination of bone strength and fracture risks. Consequently, it is very important to obtain accurate bone mineral density measurements. The microcomputerized tomography system provides 3D information about the architectural properties of bone. Quantitative analysis accuracy is decreased by the presence of artefacts in the reconstructed images, mainly due to beam hardening artefacts (such as cupping artefacts). In this paper, we introduced a new beam hardening correction method based on a postreconstruction technique performed with the use of off-line water and bone linearization curves experimentally calculated aiming to take into account the nonhomogeneity in the scanned animal. In order to evaluate the mass correction rate, calibration line has been carried out to convert the reconstructed linear attenuation coefficient into bone masses. The presented correction method was then applied on a multimaterial cylindrical phantom and on mouse skeleton images. Mass correction rate up to 18% between uncorrected and corrected images were obtained as well as a remarkable improvement of a calculated mouse femur mass has been noticed. Results were also compared to those obtained when using the simple water linearization technique which does not take into account the nonhomogeneity in the object.

  18. Thermomagnetic recording and magneto-optic playback system having constant intensity laser beam control

    NASA Technical Reports Server (NTRS)

    Lewicki, G. W.; Guisinger, J. E. (Inventor)

    1973-01-01

    A system is developed for maintaining the intensity of a laser beam at a constant level in a thermomagnetic recording and magneto-optic playback system in which an isotropic film is heated along a continuous path by the laser beam for recording. As each successive area of the path is heated locally to the vicinity of its Curie point in the presence of a controlled magnetic field, a magneto-optic density is produced proportional to the amplitude of the controlled magnetic field. To play back the recorded signal, the intensity of the laser beam is reduced and a Faraday or Kerr effect analyzer is used, with a photodetector, as a transducer for producing an output signal.

  19. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy

    PubMed Central

    Ding, Aiping; Xing, Lei; Han, Bin

    2015-01-01

    chamber measurements. The average discrepancy between EPID and ion chamber/film measurements was 0.81% ± 0.60% (SD) and 1.34% ± 0.75%, respectively. For the three clinical cases, the difference in output between the EPID- and ion chamber array measured values was found to be 1.13% ± 0.11%, 0.54% ± 0.10%, and 0.74% ± 0.11%, respectively. Furthermore, the γ-index analysis showed an excellent agreement between the EPID- and ion chamber array measured dose distributions: 100% of the pixels passed the criteria of 3%/3 mm. When the γ-index was set to be 2%/2 mm, the pass rate was found to be 99.0% ± 0.07%, 98.2% ± 0.14%, and 100% for the three cases. Conclusions: The EPID dosimetry system developed in this work provides an accurate and reliable tool for routine output measurement and dosimetric verification of electron beam therapy. Coupled with its portability and ease of use, the proposed system promises to replace the current film-based approach for fast and reliable assessment of small and irregular electron field dosimetry. PMID:26133618

  20. Phase-change recording medium that enables ultrahigh-density electron-beam data storage

    NASA Astrophysics Data System (ADS)

    Gibson, G. A.; Chaiken, A.; Nauka, K.; Yang, C. C.; Davidson, R.; Holden, A.; Bicknell, R.; Yeh, B. S.; Chen, J.; Liao, H.; Subramanian, S.; Schut, D.; Jasinski, J.; Liliental-Weber, Z.

    2005-01-01

    An ultrahigh-density electron-beam-based data storage medium is described that consists of a diode formed by growing an InSe/GaSe phase-change bilayer film epitaxially on silicon. Bits are recorded as amorphous regions in the InSe layer and are detected via the current induced in the diode by a scanned electron beam. This signal current is modulated by differences in the electrical properties of the amorphous and crystalline states. The success of this recording scheme results from the remarkable ability of layered III-VI materials, such as InSe, to maintain useful electrical properties at their surfaces after repeated cycles of amorphization and recrystallization.

  1. Holographic recordings with high beam ratios on improved Bayfol® HX photopolymer

    NASA Astrophysics Data System (ADS)

    Berneth, Horst; Bruder, Friedrich-Karl; Fäcke, Thomas; Hagen, Rainer; Hönel, Dennis; Rölle, Thomas; Walze, Günther; Weiser, Marc-Stephan

    2013-05-01

    Bayfol® HX film is a new class of recording materials for volume holography. It was commercialized in 2010 and is offering the advantages for full-color recording and moisture resistance without any chemical or thermal processing, combined with low shrinkage and detuning. These photopolymers are based on the two-chemistry concept in which the writing chemistry is dissolved in a preformed polymeric network. This network provides the necessary mechanical stability to the material prior to recording. In addition to the well-known security and imaging applications, Bayfol® HX film also offers a new opportunity for the manufacturing of volume Holographic Optical Elements (vHOEs) in new optical and optoelectronic applications. For the implementation of holographic recording layouts and associated exposure schedules for these HOEs detailed understanding of the photopolymer material properties and the knowledge how to achieve the optical requirements of dedicated holographic applications are necessary. In this paper we extend the application of our simulation method for the writing mechanism for the Bayfol® HX photopolymer film. Different photopolymer product variations, including development of photopolymer grades with improved bleaching properties and increased dynamical range, which enable simultaneous multi-color recording, while maintaining a high diffraction efficiency of the recorded holograms are covered. The model is investigated experimentally by recording and evaluation of specifically designed directional diffuser vHOEs as they would be used e.g. for light shaping or light management purposes. One important observation is the capability of Bayfol® HX film type photopolymers to form highly efficient diffraction gratings even at very high intensity ratios of the reference beam versus the object beam.

  2. Dynamics of the C(1D)+D2 reaction: a comparison of crossed molecular-beam experiments with quasiclassical trajectory and accurate statistical calculations.

    PubMed

    Balucani, Nadia; Capozza, Giovanni; Segoloni, Enrico; Russo, Andrea; Bobbenkamp, Rolf; Casavecchia, Piergiorgio; Gonzalez-Lezana, Tomas; Rackham, Edward J; Bañares, Luis; Aoiz, F Javier

    2005-06-15

    In this paper we report a combined experimental and theoretical study on the dynamics of the insertion reaction C((1)D)+D(2) at 15.5 kJ mol(-1) collision energy. Product angular and velocity distributions have been obtained in crossed beam experiments and quasiclassical trajectory (QCT) and rigorous statistical calculations have been performed on the recent and accurate ab initio potential energy surface of Bussery-Honvault, Honvault, and Launay at the energy of the experiment. The molecular-beam results have been simulated using the theoretical calculations. Good agreement between experiment and both QCT and statistical predictions is found.

  3. Fabrication and characterization of focused-ion-beam trimmed write heads for perpendicular magnetic recording

    NASA Astrophysics Data System (ADS)

    Clinton, T. W.; van der Heijden, P. A. A.; Karns, D. C.; Yu, J.; Park, C. M.; Batra, S.

    2002-05-01

    A focused ion beam (FIB) has been used to trim write heads for perpendicular magnetic recording using untrimmed HGA-level longitudinal heads. The ion-beam imaging of the write head during FIB processing was minimized to limit exposure of the active magnetic material at the ABS to a 30 keV Ga+ ion dose of less than 1014Ga+/cm2 (≈10-13 C/μm2) (the GMR reader was never exposed), which is significantly below levels where magnetic properties have been observed to degrade [W. M. Kaminsky et al., Appl. Phys. Lett. 78, 1589 (2001)]. The corresponding recording characteristics and spatial profiles of written tracks have been measured on a spin stand and a magnetic force microscope (MFM). Recording performance, such as SNR, and pulse shape of transitions, for example, as a function of head design and FIB processing is discussed, which compares very favorably to the performance of untrimmed heads. The MFM images reveal curvature in the magnetic transitions (transition smile) when writing with a single-pole writer with a straight trailing edge. Conversely, we demonstrate straight transitions using a single-pole writer with a curved trailing edge. Our results demonstrate the robustness of FIB-trimmed heads down to sub-100-nm length scales.

  4. Fast, accurate photon beam accelerator modeling using BEAMnrc: a systematic investigation of efficiency enhancing methods and cross-section data.

    PubMed

    Fragoso, Margarida; Kawrakow, Iwan; Faddegon, Bruce A; Solberg, Timothy D; Chetty, Indrin J

    2009-12-01

    In this work, an investigation of efficiency enhancing methods and cross-section data in the BEAMnrc Monte Carlo (MC) code system is presented. Additionally, BEAMnrc was compared with VMC++, another special-purpose MC code system that has recently been enhanced for the simulation of the entire treatment head. BEAMnrc and VMC++ were used to simulate a 6 MV photon beam from a Siemens Primus linear accelerator (linac) and phase space (PHSP) files were generated at 100 cm source-to-surface distance for the 10 x 10 and 40 x 40 cm2 field sizes. The BEAMnrc parameters/techniques under investigation were grouped by (i) photon and bremsstrahlung cross sections, (ii) approximate efficiency improving techniques (AEITs), (iii) variance reduction techniques (VRTs), and (iv) a VRT (bremsstrahlung photon splitting) in combination with an AEIT (charged particle range rejection). The BEAMnrc PHSP file obtained without the efficiency enhancing techniques under study or, when not possible, with their default values (e.g., EXACT algorithm for the boundary crossing algorithm) and with the default cross-section data (PEGS4 and Bethe-Heitler) was used as the "base line" for accuracy verification of the PHSP files generated from the different groups described previously. Subsequently, a selection of the PHSP files was used as input for DOSXYZnrc-based water phantom dose calculations, which were verified against measurements. The performance of the different VRTs and AEITs available in BEAMnrc and of VMC++ was specified by the relative efficiency, i.e., by the efficiency of the MC simulation relative to that of the BEAMnrc base-line calculation. The highest relative efficiencies were approximately 935 (approximately 111 min on a single 2.6 GHz processor) and approximately 200 (approximately 45 min on a single processor) for the 10 x 10 field size with 50 million histories and 40 x 40 cm2 field size with 100 million histories, respectively, using the VRT directional bremsstrahlung splitting

  5. Phase Space Tomography: A Simple, Portable and Accurate Technique to Map Phase Spaces of Beams with Space Charge

    SciTech Connect

    Stratakis, D.; Kishek, R. A.; Bernal, S.; Walter, M.; Haber, I.; Fiorito, R.; Thangaraj, J. C. T.; Quinn, B.; Reiser, M.; O'Shea, P. G.; Li, H.

    2006-11-27

    In order to understand the charged particle dynamics, e.g. the halo formation, emittance growth, x-y energy transfer and coupling, knowledge of the actual phase space is needed. Other the past decade there is an increasing number of articles who use tomography to map the beam phase space and measure the beam emittance. These studies where performed at high energy facilities where the effect of space charge was neglible and therefore not considered in the analysis. This work extends the tomography technique to beams with space charge. In order to simplify the analysis linear forces where assumed. By carefully modeling the tomography process using the particle-in-cell code WARP we test the validity of our assumptions and the accuracy of the reconstructed phase space. Finally, we report experimental results of phase space mapping at the University of Maryland Electron Ring (UMER) using tomography.

  6. Sub-100-nm trackwidth development by e-beam lithography for advanced magnetic recording heads

    NASA Astrophysics Data System (ADS)

    Chang, Jei-Wei; Chen, Chao-Peng

    2006-03-01

    Although semiconductor industry ramps the products with 90 nm much quicker than anticipated [1], magnetic recording head manufacturers still have difficulties in producing sub-100 nm read/write trackwidth. Patterning for high-aspectratio writer requires much higher depth of focus (DOF) than most advanced optical lithography, including immersion technique developed recently [2]. Self-aligning reader with its stabilized bias requires a bi-layer lift-off structure where the underlayer is narrower than the top image layer. As the reader's trackwidth is below 100nm, the underlayer becomes very difficult to control. Among available approaches, e-beam lithography remains the most promising one to overcome the challenge of progressive miniaturization. In this communication, the authors discussed several approaches using ebeam lithography to achieve sub-100 nm read/write trackwidth. Our studies indicated the suspended resist bridge design can not only widen the process window for lift-off process but also makes 65 nm trackwidth feasible to manufacture. Necked dog-bone structure seems to be the best design in this application due to less proximity effects from adjacent structures and minimum blockages for ion beam etching. The trackwidth smaller than 65 nm can be fabricated via the combination of e-beam lithography with auxiliary slimming and/or trimming. However, deposit overspray through undercut becomes dominated in such a small dimension. To minimize the overspray, the effects of underlayer thickness need to be further studied.

  7. Accurate Iterative Analysis Solution of theKapchinskij-Vladimirskij Equations for the Case of a Matched Beam

    SciTech Connect

    Anderson, O.A.

    2007-01-31

    The well-known Kapchinskij-Vladimirskij (KV) equations are difficult to solve in general, but the problem is simplified for the matched-beam case with sufficient symmetry. They show that the interdependence of the two KV equations is eliminated, so that only one needs to be solved--a great simplification. They present an iterative method of solution which can potentially yield any desired level of accuracy. The lowest level, the well-known smooth approximation, yields simple, explicit results with good accuracy for weak or moderate focusing fields. The next level improves the accuracy for high fields; they previously showed [Part. Accel. 52, 133 (1996)] how to maintain a simple explicit format for the results. That paper used expansion in a small parameter to obtain results of second-level accuracy. The present paper, using straightforward iteration, obtains equations of first, second, and third levels of accuracy. For a periodic lattice with beam matched to lattice, they use the lattice and beam parameters as input and solve for phase advances and envelope functions. They find excellent agreement with numerical solutions over a wide range of beam emittances and intensities.

  8. Accurate iterative analytic solution of theKapchinskij-Vladimirskij equations for the case of a matched beam

    SciTech Connect

    Anderson, Oscar A.

    2006-08-06

    The well-known Kapchinskij-Vladimirskij (KV) equations are difficult to solve in general, but the problem is simplified for the matched-beam case with sufficient symmetry. They show that the interdependence of the two KV equations is eliminated, so that only one needs to be solved--a great simplification. They present an iterative method of solution which can potentially yield any desired level of accuracy. The lowest level, the well-known smooth approximation, yields simple, explicit results with good accuracy for weak or moderate focusing fields. The next level improves the accuracy for high fields; they previously showed how to maintain a simple explicit format for the results. That paper used expansion in a small parameter to obtain the second level. The present paper, using straightforward iteration, obtains equations of first, second, and third levels of accuracy. For a periodic lattice with beam matched to lattice, they use the lattice and beam parameters as input and solve for phase advances and envelope waveforms. They find excellent agreement with numerical solutions over a wide range of beam emittances and intensities.

  9. Characterizing and Mapping Ice Sheet Surface Topography Using a Medium-Footprint, Multi- Beam, Waveform-Recording Lidar

    NASA Astrophysics Data System (ADS)

    Hofton, M. A.; Blair, J. B.; Rabine, D. L.; Luthcke, S. B.

    2007-12-01

    Lidar surveys of the Greenland ice sheet have been used to study mass-balance changes since the early 1990's. Sensors include NASA's ATM system (e.g., Krabill et al., 2000), and the ICESat (Schutz et al., 2002), a large- footprint, spaceborne system launched in 2003 for monitoring long-term trends in ice mass balance. To complement these data sets and prepare for the next-generation of spaceborne measurements, the Laser Vegetation Imaging Sensor (LVIS) was flown onboard the NASA P-3 aircraft over Greenland in September 2007. LVIS is an airborne, medium- footprint (25m diameter), full waveform-recording, airborne, scanning lidar system that has been used extensively for mapping forest structure, habitat, carbon and natural hazards. The system digitally records the shape of the returning laser echo, or waveform, after its interaction with the various reflecting surfaces of the earth, providing a true 3-dimensional record of the surface structure. Data collected included ground elevation and vertical extent measurements for each laser footprint, as well as the vertical distribution of intercepted surfaces (the return waveform) from which surface slope, roughness and other metrics can be extracted. During the mission, data were collected along ICESat repeat ground-track "corridors" that encompass a variety of terrain types (e.g., inland ice, crevasses, ponds, sastrugi, ice/rock margins, and bare earth), over sea- ice in northern Greenland, and at Jakobshavn Isbrae, a fast-flowing outlet glacier where discharge rates have increased in recent years. Data from this mission will be used to assess the ability of 25m-footprint, waveform lidar to precisely and accurately characterize and monitor the surface of the Greenland ice sheet and its margins. The data will also be used to assess the effects of across-track slope corrections currently being used on the ICESat data. The study will highlight the complimentary measurement science that can be achieved using a multi-beam

  10. An approach to an accurate determination of the energy spectrum of high-energy electron beams using magnetic spectrometry

    NASA Astrophysics Data System (ADS)

    Renner, F.; Schwab, A.; Kapsch, R.-P.; Makowski, Ch; Jannek, D.

    2014-03-01

    At the national metrology institute of Germany, the Physikalisch-Technische Bundesanstalt, a research accelerator for dosimetry in radiation therapy has been installed. Magnetic spectrometry is used to determine the spectrum of high-energy electrons generated by this accelerator. Regarding the intended experiments at the accelerator, a high accuracy for the energy determination of the electron beam is required. For this purpose, an experimental setup is used that has a number of additional devices assembled around the spectrometer to determine geometric characteristics of the electron beam, which influence the energy analysis. For the analysis of the acquired data, a software was developed which meets specific needs. One important aspect is that the software is based on an algorithm for energy determination which considers the measured magnetic flux density of the spectrometer and geometric details of the beam and the spectrometer. The software also meets the demand that it can be used to estimate the uncertainty assigned to the energy. This paper covers the experimental and analytical background of magnetic spectrometry at the high-energy beamline of PTB's research accelerator. A comparison of results calculated with the specific algorithm for energy determination which was developed for this experimental setup and with well-known algorithms is given to show the advantage of the specific method. Results of measurements and their analysis with the algorithm are presented as well.

  11. Identification of fidgety movements and prediction of CP by the use of computer-based video analysis is more accurate when based on two video recordings.

    PubMed

    Adde, Lars; Helbostad, Jorunn; Jensenius, Alexander R; Langaas, Mette; Støen, Ragnhild

    2013-08-01

    This study evaluates the role of postterm age at assessment and the use of one or two video recordings for the detection of fidgety movements (FMs) and prediction of cerebral palsy (CP) using computer vision software. Recordings between 9 and 17 weeks postterm age from 52 preterm and term infants (24 boys, 28 girls; 26 born preterm) were used. Recordings were analyzed using computer vision software. Movement variables, derived from differences between subsequent video frames, were used for quantitative analysis. Sensitivities, specificities, and area under curve were estimated for the first and second recording, or a mean of both. FMs were classified based on the Prechtl approach of general movement assessment. CP status was reported at 2 years. Nine children developed CP of whom all recordings had absent FMs. The mean variability of the centroid of motion (CSD) from two recordings was more accurate than using only one recording, and identified all children who were diagnosed with CP at 2 years. Age at assessment did not influence the detection of FMs or prediction of CP. The accuracy of computer vision techniques in identifying FMs and predicting CP based on two recordings should be confirmed in future studies.

  12. Fluorescence of Supported Phospholipid Bilayers Recorded in a Conventional Horizontal-Beam Spectrofluorometer.

    PubMed

    Kovrigina, Elizaveta A; Kovrigin, Evgenii L

    2016-03-01

    Supported phospholipid bilayers are a convenient model of cellular membranes in studies of membrane biophysics and protein-lipid interactions. Traditionally, supported lipid bilayers are formed on a flat surface of a glass slide to be observed through fluorescence microscopes. This paper describes a method to enable fluorescence detection from the supported lipid bilayers using standard horizontal-beam spectrofluorometers instead of the microscopes. In the proposed approach, the supported lipid bilayers are formed on the inner optical surfaces of the standard fluorescence microcell. To enable observation of the bilayer absorbed on the cell wall, the microcell is placed in a standard fluorometer cell holder and specifically oriented to expose the inner cell walls to both excitation and emission channels with a help of the custom cell adaptor. The signal intensity from supported bilayers doped with 1 % (mol) of rhodamine-labeled lipid in the standard 3-mm optical microcell was equivalent to fluorescence of the 70-80 nM reference solution of rhodamine recorded in a commercial microcell adaptor. Because no modifications to the instruments are required in this method, a variety of steady-state and time-domain fluorescence measurements of the supported phospholipid bilayers may be performed with the spectral resolution using standard horizontal-beam spectrofluorometers.

  13. The readout of the LHC beam luminosity monitor: Accurate shower energy measurements at a 40 MHz repetition rate

    SciTech Connect

    Manfredi, P.F.; Ratti, L.; Speziali, V.; Traversi, G.; Manghisoni, M.; Re, V.; Denes, P.; Placidi, M.; Ratti, A.; Turner, W.C.; Datte, P.S.; Millaud, J.E.

    2003-05-10

    The LHC beam luminosity monitor is based on the following principle. The neutrals that originate in LHC at every PP interaction create showers in the absorbers placed in front of the cryogenic separation dipoles. The shower energy, as it can be measured by suitable detectors in the absorbers is proportional to the number of neutral particles and, therefore, to the luminosity. This principle lends itself to a luminosity measurement on a bunch-by-bunch basis. However, detector and front-end electronics must comply with extremely stringent requirements. To make the bunch-by-bunch measurement feasible, their speed of operation must match the 40 MHz bunch repetition rate of LHC. Besides, in the actual operation the detector must stand extremely high radiation doses. The front-end electronics, to survive, must be located at some distance from the region of high radiation field, which means that a properly terminated, low-noise, cable connection is needed between detector and front-end electronics. After briefly reviewing the solutions that have been adopted for the detector and the front-end electronics and the results that have been obtained so far in tests on the beam, the latest version of the instrument in describe in detail. It will be shown how a clever detector design, a suitable front-end conception based on the use of a ''cold resistance'' cable termination and a careful low-noise design, along with the use of an effective deconvolution algorithm, make the luminosity measurement possible on a bunch-by-bunch basis at the LHC bunch repetition rates.

  14. Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: What level is achievable?

    SciTech Connect

    Battum, L. J. van; Hoffmans, D.; Piersma, H.; Heukelom, S.

    2008-02-15

    This paper focuses on the accuracy, in absolute dose measurements, with GafChromic EBT film achievable in water for a 6 MV photon beam up to a dose of 2.3 Gy. Motivation is to get an absolute dose detection system to measure up dose distributions in a (water) phantom, to check dose calculations. An Epson 1680 color (red green blue) transmission flatbed scanner has been used as film scanning system, where the response in the red color channel has been extracted and used for the analyses. The influence of the flatbed film scanner on the film based dose detection process was investigated. The scan procedure has been optimized; i.e. for instance a lateral correction curve was derived to correct the scan value, up to 10%, as a function of optical density and lateral position. Sensitometric curves of different film batches were evaluated in portrait and landscape scan mode. Between various batches important variations in sensitometric curve were observed. Energy dependence of the film is negligible, while a slight variation in dose response is observed for very large angles between film surface and incident photon beam. Improved accuracy in absolute dose detection can be obtained by repetition of a film measurement to tackle at least the inherent presence of film inhomogeneous construction. We state that the overall uncertainty is random in absolute EBT film dose detection and of the order of 1.3% (1 SD) under the condition that the film is scanned in a limited centered area on the scanner and at least two films have been applied. At last we advise to check a new film batch on its characteristics compared to available information, before using that batch for absolute dose measurements.

  15. SU-E-T-273: Do Task Group External Beam QA Recommendations Guarantee Accurate Treatment Plan Dose Delivery?

    SciTech Connect

    Templeton, A; Liao, Y; Redler, G; Zhen, H

    2015-06-15

    Purpose: AAPM task groups 40/142 have provided an invaluable set of goals for physicists designing QA programs, attempting to standardize what would otherwise likely be a highly variable phenomenon across institutions. However, with the complexity of modalities such as VMAT, we hypothesize that following these guidelines to the letter might still allow unacceptable dose discrepancies. To explore this hypothesis we simulated machines bordering on QA acceptability, and calculated the effect on patient plans. Methods: Two errant machines were simulated in Aria/Eclipse, each just within task group criteria for output, percent depth dose, beam profile, gantry and collimator rotations, and jaw and MLC positions. One machine minimized dose to the PTV (machine A) and the other maximized dose to the OARs (machine B). Clinical treatment plans (3-phase prostate, n=3; hypofractionated lung, n=1) were calculated on these machines and the dose distributions compared. A prostate case was examined for contribution of error sources and evaluated using delivery QA data. Results: The prostate plans showed mean decreases in target D95 of 9.9% of prescription dose on machine A. On machine B, The rectal and bladder V70Gy each increased by 7.1 percentage points, while their V45Gy increased by 16.2% and 15.0% respectively. In the lung plan, the target D95 decreased by 12.8% and the bronchial tree Dmax increased by 21% of prescription dose, on machines A and B. One prostate plan showed target dose errors of 3.8% from MLC changes, 2% from output, ∼3% from energy and ∼0.5% from other factors. This plan achieved an 88.4% gamma passing rate using 3%/3mm using ArcCHECK. Conclusion: In the unlikely event that a machine exhibits all maximum errors allowed by TG 40/142, unacceptably large changes in dose delivered are possible especially in highly modulated VMAT plans, despite the machine passing routine QA.

  16. Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

    PubMed

    Meganck, Jeffrey A; Kozloff, Kenneth M; Thornton, Michael M; Broski, Stephen M; Goldstein, Steven A

    2009-12-01

    Bone mineral density (BMD) measurements are critical in many research studies investigating skeletal integrity. For pre-clinical research, micro-computed tomography (microCT) has become an essential tool in these studies. However, the ability to measure the BMD directly from microCT images can be biased by artifacts, such as beam hardening, in the image. This three-part study was designed to understand how the image acquisition process can affect the resulting BMD measurements and to verify that the BMD measurements are accurate. In the first part of this study, the effect of beam hardening-induced cupping artifacts on BMD measurements was examined. In the second part of this study, the number of bones in the X-ray path and the sampling process during scanning was examined. In the third part of this study, microCT-based BMD measurements were compared with ash weights to verify the accuracy of the measurements. The results indicate that beam hardening artifacts of up to 32.6% can occur in sample sizes of interest in studies investigating mineralized tissue and affect mineral density measurements. Beam filtration can be used to minimize these artifacts. The results also indicate that, for murine femora, the scan setup can impact densitometry measurements for both cortical and trabecular bone and morphologic measurements of trabecular bone. Last, when a scan setup that minimized all of these artifacts was used, the microCT-based measurements correlated well with ash weight measurements (R(2)=0.983 when air was excluded), indicating that microCT can be an accurate tool for murine bone densitometry.

  17. Close Range Uav Accurate Recording and Modeling of St-Pierre Neo-Romanesque Church in Strasbourg (france)

    NASA Astrophysics Data System (ADS)

    Murtiyoso, A.; Grussenmeyer, P.; Freville, T.

    2017-02-01

    Close-range photogrammetry is an image-based technique which has often been used for the 3D documentation of heritage objects. Recently, advances in the field of image processing and UAVs (Unmanned Aerial Vehicles) have resulted in a renewed interest in this technique. However, commercially ready-to-use UAVs are often equipped with smaller sensors in order to minimize payload and the quality of the documentation is still an issue. In this research, two commercial UAVs (the Sensefly Albris and DJI Phantom 3 Professional) were setup to record the 19th century St-Pierre-le-Jeune church in Strasbourg, France. Several software solutions (commercial and open source) were used to compare both UAVs' images in terms of calibration, accuracy of external orientation, as well as dense matching. Results show some instability in regards to the calibration of Phantom 3, while the Albris had issues regarding its aerotriangulation results. Despite these shortcomings, both UAVs succeeded in producing dense point clouds of up to a few centimeters in accuracy, which is largely sufficient for the purposes of a city 3D GIS (Geographical Information System). The acquisition of close range images using UAVs also provides greater LoD flexibility in processing. These advantages over other methods such as the TLS (Terrestrial Laser Scanning) or terrestrial close range photogrammetry can be exploited in order for these techniques to complement each other.

  18. Making Accurate Topographic Maps of the Schoolyard Using Ideas and Techniques Learned and Adapted from Multi-beam Sonar Mapping of the Arctic Ocean

    NASA Astrophysics Data System (ADS)

    Fuerst, S. I.; Roberts, J. D.

    2010-12-01

    Having participated in a University of Rhode Island Project Armada expedition to join the University of New Hampshire Center for Coastal and Oceanographic Studies in making multi-beam sonar contour maps of the Arctic Ocean floor, I was able to bring the principles learned from this trip to my earth science high school students and create a project in our "mapping the earth" unit. Students learn basic surveying techniques and create authentic, accurately detailed topographic maps of the schoolyard. Models of their maps are then constructed of either Styrofoam or wood which enables them to make the transition from a 2-dimensional map to a 3-dimensional representation. Even though our maps are created using sticks, line levels, compasses and GPS, the scientific concepts of using location and elevation data to draw contour lines are identical to those used in underwater mapping. Once the students understand the science in mapping and creating contour maps to scale on graph paper by hand, they are able to easily relate this knowledge to what I was doing onboard ship using multi-beam sonar and computer mapping programs. We would like to share with you the lab and techniques that we have developed to make this activity possible with minimal materials and simple technology. As a background extension, it is also possible to replicate sonar measurements using an aquarium, food coloring, and a surface grid to map the topography of a teacher created landscape on the aquarium bottom. Earth Science students using simple tools to accurately map the topography of the school grounds

  19. Accurate tuning of emission of GaInAsP/InP heterostructures in multiwafer gas-source molecular-beam epitaxy

    NASA Astrophysics Data System (ADS)

    Lelarge, F.; Gaborit, F.; Gentner, J. L.

    2005-03-01

    Photoluminescence wavelength emission of Ga xIn 1-xAs yP 1-y/InP heterostructures grown in multiwafer gas-source molecular-beam epitaxy (GSMBE) is studied in detail for both bulk and multiple quantum well (MQWs) heterostructures. Excellent photoluminescence wavelength uniformity is reported in 4×2-in. configuration, demonstrating the compatibility of GSMBE process with large-scale 1.55 μm telecom laser production. A strong dependence of wavelength uniformity on group-V/group-III flux ratio is reported and analyzed quantitatively. An empirical model based on the interplay between group-V elements incorporation and gas distribution is proposed to predict the influence of AsH 3 and PH 3 fluxes on As content in the solid. This understanding opens the way to an accurate tuning of wavelength dispersion of Ga xIn 1-xAs yP 1-y/InP MQWs grown in multiwafer GSMBE system.

  20. Self-monitoring of dietary intake by young women: online food records completed on computer or smartphone are as accurate as paper-based food records but more acceptable.

    PubMed

    Hutchesson, Melinda J; Rollo, Megan E; Callister, Robin; Collins, Clare E

    2015-01-01

    Adherence and accuracy of self-monitoring of dietary intake influences success in weight management interventions. Information technologies such as computers and smartphones have the potential to improve adherence and accuracy by reducing the burden associated with monitoring dietary intake using traditional paper-based food records. We evaluated the acceptability and accuracy of three different 7-day food record methods (online accessed via computer, online accessed via smartphone, and paper-based). Young women (N=18; aged 23.4±2.9 years; body mass index 24.0±2.2) completed the three 7-day food records in random order with 7-day washout periods between each method. Total energy expenditure (TEE) was derived from resting energy expenditure (REE) measured by indirect calorimetry and physical activity level (PAL) derived from accelerometers (TEE=REE×PAL). Accuracy of the three methods was assessed by calculating absolute (energy intake [EI]-TEE) and percentage difference (EI/TEE×100) between self-reported EI and TEE. Acceptability was assessed via questionnaire. Mean±standard deviation TEE was 2,185±302 kcal/day and EI was 1,729±249 kcal/day, 1,675±287kcal/day, and 1,682±352 kcal/day for computer, smartphone, and paper records, respectively. There were no significant differences between absolute and percentage differences between EI and TEE for the three methods: computer, -510±389 kcal/day (78%); smartphone, -456±372 kcal/day (80%); and paper, -503±513 kcal/day (79%). Half of participants (n=9) preferred computer recording, 44.4% preferred smartphone, and 5.6% preferred paper-based records. Most participants (89%) least preferred the paper-based record. Because online food records completed on either computer or smartphone were as accurate as paper-based records but more acceptable to young women, they should be considered when self-monitoring of intake is recommended to young women.

  1. Diurnal patterns of salivary cortisol and DHEA using a novel collection device: Electronic monitoring confirms accurate recording of collection time using this device

    PubMed Central

    Laudenslager, Mark L.; Calderone, Jacqueline; Philips, Sam; Natvig, Crystal; Carlson, Nichole E.

    2013-01-01

    The accurate indication of saliva collection time is important for defining the diurnal decline in salivary cortisol as well as characterizing the cortisol awakening response.. We tested a convenient and novel collection device for collecting saliva on strips of filter paper in a specially constructed booklet for determination of both cortisol and DHEA. In the present study, 31 healthy adults (mean age 43.5 yrs.) collected saliva samples four times a day on three consecutive days using filter paper collection devices (Saliva Procurement and Integrated Testing (SPIT) booklet) which were maintained during the collection period in a large plastic bottle with an electronic monitoring cap. Subjects were asked to collect saliva samples at awakening, 30 min. after awakening, before lunch and 600 min. after awakening. The time of awakening and the time of collection before lunch were allowed to vary by each subjects’ schedule. A reliable relationship was observed between the time recorded by the subject directly on the booklet and the time recorded by electronic collection device (n = 286 observations; r2 = 0.98). However, subjects did not consistently collect the saliva samples at the two specific times requested, 30 and 600 min. after awakening. Both cortisol and DHEA revealed diurnal declines.. In spite of variance in collection times at 30 min. and 600 min. after awakening, the slope of the diurnal decline in both salivary cortisol and DHEA were similar when we compared collection tolerances of ± 7.5 and ± 15 min. for each steroid.. These unique collection booklets proved to be a reliable method for recording collection times by subjects as well as for estimating diurnal salivary cortisol and DHEA patterns. PMID:23490073

  2. Cosmogenic Beryllium Production from Ocean Sediment Sequences Help to Construct Accurate Records of the Geodynamo Variation at the Millennial to Million Year Scale

    NASA Astrophysics Data System (ADS)

    Thouveny, N.; Ménabréaz, L.; Bourles, D. L.; Demory, F.; Guillou, V.; Arnold, M.; Vidal, L.

    2013-12-01

    The possible contribution of the axial precession to the energy of the geodynamo was recently reintroduced by theoretical and experimental studies. It is supported by relative paleointensity stacks and deep sea floor magnetization records documenting series of geomagnetic dipole lows (GDL) with recurrence at periods ranging from 30 to 120 kyr, and intriguing phase relationships with obliquity variations and δ18O records (e.g. Fuller, 2006; Thouveny et al. 2008). Yet, these time-series are presently not precise and complete enough to validate this fundamental and debated relationship. The MAG-ORB project funded by the French "Agence nationale de la Recherche" aims at reconstructing the series of GDL over the last Ma, by coupling -on the very same sedimentary sequences- the reconstructions of paleomagnetic variations, cosmogenic10Be production variations and δ18O isotope variations. Recent results (e.g. Ménabréaz et al., 2012, 2013) demonstrate that 10Be overproduction events are systematically induced by the GDL linked with excursions and reversals -as awaited from the theoretical and empirical non linear inverse relationship established between the magnetic moment value and the penetration rate of cosmic rays and particles. The calibration of the authigenic 10Be/9Be ratio signals using absolute Virtual (axial) Dipole Moment values allowed us to construct 10Be-derived Geomagnetic Dipole Moment records over the last millennium, the last 60 ka and the last Ma, allowing to assess the robustness of the GDL series by a method completely independent from rock and paleo-magnetic methods. These records are comparable with individuals RPI records obtained from the same cores, and with global RPI stacks (e.g. GLOPIS, SINT 800 and PISO-1500). Since the Beryllium atoms are adsorbed on the settling silicate particles, the measured 10Be/9Be ratio signatures of cosmogenic isotope overproductions accurately indicate the exact stratigraphic position of the GDL in the sedimentary

  3. Electron-Beam Detection of Bits Reversibly Recorded on Epitaxial InSe/GaSe/Si Phase-Change Diodes

    NASA Astrophysics Data System (ADS)

    Chaiken, Alison; Gibson, Gary A.; Chen, John; Yeh, Bao S.; Jasinski, J. B.; Liliental‑Weber, Z.; Nauka, K.; Yang, C. C.; Lindig, D. D.; Subramanian, S.

    2006-04-01

    We demonstrate a data read-back scheme based on electron-beam induced current in a data storage device that utilizes thermal recording onto a phase-change medium. The phase-change medium is part of a heterojunction diode whose local charge-collection efficiency depends on the crystalline or amorphous state of a bit. Current gains up to 65 at 2 keV electron beam energy have been demonstrated using InSe/GaSe/Si epitaxial diodes. Fifteen write-erase cycles are obtained without loss of signal contrast by using a protective cap layer and short write pulses. 100 write-erase cycles have been achieved with some loss of contrast. Erasure times for the bits are longer than in similar polycrystalline In-Se media films. Possible reasons for the long erasure times are discussed in terms of a nucleation- or growth-dominated recrystallization. Prospects for extension to smaller bit sizes using electron-beam writing are considered.

  4. Accurate wavelength measurements and modeling of FeXV to FeXIX spectra recorded in high density plasmas between 13.5 to 17 A.

    SciTech Connect

    May, M; Beiersdorfer, P; Dunn, J; Jordan, N; Osterheld, A; Faenov, A; Pikuz, T; Skobelev, I; Fora, F; Bollanti, S; Lazzaro, P D; Murra, D; Reale, A; Reale, L; Tomassetti, G; Ritucci, A; Francucci, M; Martellucci, S; Petrocelli, G

    2004-09-28

    Iron spectra have been recorded from plasmas created at three different laser plasma facilities, the Tor Vergata University laser in Rome (Italy), the Hercules laser at ENEA in Frascati (Italy), and the Compact Multipulse Terawatt (COMET) laser at LLNL in California (USA). The measurements provide a means of identifying dielectronic satellite lines from FeXVI and FeXV in the vicinity of the strong 2p {yields} 3d transitions of FeXVII. About 80 {Delta}n {ge} 1 lines of FeXV (Mg-like) to FeXIX (O-like) were recorded between 13.8 to 17.1 {angstrom} with a high spectral resolution ({lambda}/{Delta}{lambda} {approx} 4000), about thirty of these lines are from FeXVI and FeXV. The laser produced plasmas had electron temperatures between 100 to 500 eV and electron densities between 10{sup 20} to 10{sup 22} cm{sup -3}. The Hebrew University Lawrence Livermore Atomic Code (HULLAC) was used to calculate the atomic structure and atomic rates for FeXV to FeXIX. HULLAC was used to calculate synthetic line intensities at T{sub e} = 200 eV and n{sub e} = 10{sup 21}cm{sup -3} for three different conditions to illustrate the role of opacity: optically thin plasmas with no excitation-autoionization/dielectronic recombination (EA/DR) contributions to the line intensities, optically thin plasmas that included EA/DR contributions to the line intensities, and optically thick plasmas (optical depth {approx} 200 {micro}m) that included EA/DR contributions to the line intensities. The optically thick simulation best reproduced the recorded spectrum from the Hercules laser. However some discrepancies between the modeling and the recorded spectra remain.

  5. Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.

    PubMed

    Regidor, Ignacio; de Blas, Gema; Barrios, Carlos; Burgos, Jesús; Montes, Elena; García-Urquiza, Sergio; Hevia, Edurado

    2011-10-01

    This study was aimed at evaluating the sensitivity and safety of a new technique to record triggered EMG thresholds from axillary chest wall electrodes when inserting pedicle screws in the upper thoracic spine (T2-T6). A total of 248 (36.6%) of a total of 677 thoracic screws were placed at the T2-T6 levels in 92 patients with adolescent idiopathic scoliosis. A single electrode placed at the axillary midline was able to record potentials during surgery from all T2-T6 myotomes at each side. Eleven screws were removed during surgery because of malposition according to intraoperative fluoroscopic views. Screw position was evaluated after surgery in the remaining 237 screws using a CT scan. Malposition was detected in 35 pedicle screws (14.7%). Pedicle medial cortex was breached in 24 (10.1%). Six screws (2.5%) were located inside the spinal canal. Mean EMG threshold was 24.44 ± 11.30 mA in well-positioned screws, 17.98 ± 8.24 mA (p < 0.01) in screws violating the pedicle medial cortex, and 10.38 ± 3.33 mA (p < 0.005) in screws located inside the spinal canal. Below a threshold of 12 mA, 33.4% of the screws (10/30) were malpositioned. Furthermore, 36% of the pedicle screws with t-EMG stimulation thresholds within the range 6-12 mA were malpositioned. In conclusion, assessment of upper thoracic pedicle screw placement by recording tEMG at a single axillary electrode was highly reliable. Thresholds below 12 mA should alert surgeons to suspect screw malposition. This technique simplifies tEMG potential recording to facilitate safe placement of pedicle screws at upper thoracic levels.

  6. Accurate IMRT fluence verification for prostate cancer patients using ‘in-vivo’ measured EPID images and in-room acquired kilovoltage cone-beam CT scans

    PubMed Central

    2013-01-01

    Background To investigate for prostate cancer patients the comparison of ‘in-vivo’ measured portal dose images (PDIs) with predictions based on a kilovoltage cone-beam CT scan (CBCT), acquired during the same treatment fraction, as an alternative for pre-treatment verification. For evaluation purposes, predictions were also performed using the patients’ planning CTs (pCT). Methods To get reliable CBCT electron densities for PDI predictions, Hounsfield units from the pCT were mapped onto the CBCT, while accounting for non-rigidity in patient anatomy in an approximate way. PDI prediction accuracy was first validated for an anatomical phantom, using IMRT treatment plans of ten prostate cancer patients. Clinical performance was studied using data acquired for 50 prostate cancer patients. For each patient, 4–5 CBCTs were available, resulting in a total of 1413 evaluated images. Measured and predicted PDIs were compared using γ-analyses with 3% global dose difference and 3 mm distance to agreement as reference criteria. Moreover, the pass rate for automated PDI comparison was assessed. To quantify improvements in IMRT fluence verification accuracy results from multiple fractions were combined by generating a γ-image with values halfway the minimum and median γ values, pixel by pixel. Results For patients, CBCT-based PDI predictions showed a high agreement with measurements, with an average percentage of rejected pixels of 1.41% only. In spite of possible intra-fraction motion and anatomy changes, this was only slightly larger than for phantom measurements (0.86%). For pCT-based predictions, the agreement deteriorated (average percentage of rejected pixels 2.98%), due to an enhanced impact of anatomy variations. For predictions based on CBCT, combination of the first 2 fractions yielded gamma results in close agreement with pre-treatment analyses (average percentage of rejected pixels 0.63% versus 0.35%, percentage of rejected beams 0.6% versus 0%). For the p

  7. Large magnetic to electric field contrast in azimuthally polarized vortex beams generated by a metasurface (Presentation Recording)

    NASA Astrophysics Data System (ADS)

    Veysi, Mehdi; Guclu, Caner; Capolino, Filippo

    2015-09-01

    We investigate azimuthally E-polarized vortex beams with enhanced longitudinal magnetic field. Ideally, such beams possess strong longitudinal magnetic field on the beam axis where there is no electric field. First we formulate the electric field vector and the longitudinal magnetic field of an azimuthally E-polarized beam as an interference of right- and left-hand circularly polarized Laguerre Gaussian (LG) beams carrying the orbital angular momentum (OAM) states of -1 and +1, respectively. Then we propose a metasurface design that is capable of converting a linearly polarized Gaussian beam into an azimuthally E-polarized vortex beam with longitudinal magnetic field. The metasurface is composed of a rectangular array of double-layer double split-ring slot elements, though other geometries could be adopted as well. The element is specifically designed to have nearly a 180° transmission phase difference between the two polarization components along two orthogonal axes, similar to the optical axes of a half-wave plate. By locally rotating the optical axes of each metasurface element, the transmission phase profile of the circularly polarized waves over the metasurface can be tailored. Upon focusing of the generated vortex beam through a lens with a numerical aperture of 0.7, a 41-fold enhancement of the magnetic to electric field ratio is achieved on the beam axis with respect to that of a plane wave. Generation of beams with large magnetic field to electric field contrast can find applications in future spectroscopy systems based on magnetic dipole transitions, which are usually much weaker than electric dipole transitions.

  8. Lake sediment multi-taxon DNA from North Greenland records early post-glacial appearance of vascular plants and accurately tracks environmental changes

    NASA Astrophysics Data System (ADS)

    Epp, L. S.; Gussarova, G.; Boessenkool, S.; Olsen, J.; Haile, J.; Schrøder-Nielsen, A.; Ludikova, A.; Hassel, K.; Stenøien, H. K.; Funder, S.; Willerslev, E.; Kjær, K.; Brochmann, C.

    2015-06-01

    High Arctic environments are particularly sensitive to climate changes, but retrieval of paleoecological data is challenging due to low productivity and biomass. At the same time, Arctic soils and sediments have proven exceptional for long-term DNA preservation due to their constantly low temperatures. Lake sediments contain DNA paleorecords of the surrounding ecosystems and can be used to retrieve a variety of organismal groups from a single sample. In this study, we analyzed vascular plant, bryophyte, algal (in particular diatom) and copepod DNA retrieved from a sediment core spanning the Holocene, taken from Bliss Lake on the northernmost coast of Greenland. A previous multi-proxy study including microscopic diatom analyses showed that this lake experienced changes between marine and lacustrine conditions. We inferred the same environmental changes from algal DNA preserved in the sediment core. Our DNA record was stratigraphically coherent, with no indication of leaching between layers, and our cross-taxon comparisons were in accordance with previously inferred local ecosystem changes. Authentic ancient plant DNA was retrieved from nearly all layers, both from the marine and the limnic phases, and distinct temporal changes in plant presence were recovered. The plant DNA was mostly in agreement with expected vegetation history, but very early occurrences of vascular plants, including the woody Empetrum nigrum, document terrestrial vegetation very shortly after glacial retreat. Our study shows that multi-taxon metabarcoding of sedimentary ancient DNA from lake cores is a valuable tool both for terrestrial and aquatic paleoecology, even in low-productivity ecosystems such as the High Arctic.

  9. Optical trapping of nanoparticles with significantly reduced laser powers by using counter-propagating beams (Presentation Recording)

    NASA Astrophysics Data System (ADS)

    Zhao, Chenglong; LeBrun, Thomas W.

    2015-08-01

    Gold nanoparticles (GNP) have wide applications ranging from nanoscale heating to cancer therapy and biological sensing. Optical trapping of GNPs as small as 18 nm has been successfully achieved with laser power as high as 855 mW, but such high powers can damage trapped particles (particularly biological systems) as well heat the fluid, thereby destabilizing the trap. In this article, we show that counter propagating beams (CPB) can successfully trap GNP with laser powers reduced by a factor of 50 compared to that with a single beam. The trapping position of a GNP inside a counter-propagating trap can be easily modulated by either changing the relative power or position of the two beams. Furthermore, we find that under our conditions while a single-beam most stably traps a single particle, the counter-propagating beam can more easily trap multiple particles. This (CPB) trap is compatible with the feedback control system we recently demonstrated to increase the trapping lifetimes of nanoparticles by more than an order of magnitude. Thus, we believe that the future development of advanced trapping techniques combining counter-propagating traps together with control systems should significantly extend the capabilities of optical manipulation of nanoparticles for prototyping and testing 3D nanodevices and bio-sensing.

  10. SU-E-J-100: The Combination of Deformable Image Registration and Regions-Of-Interest Mapping Technique to Accomplish Accurate Dose Calculation On Cone Beam Computed Tomography for Esophageal Cancer

    SciTech Connect

    Huang, B-T; Lu, J-Y

    2015-06-15

    Purpose: We introduce a new method combined with the deformable image registration (DIR) and regions-of-interest mapping (ROIM) technique to accurately calculate dose on daily CBCT for esophageal cancer. Methods: Patients suffered from esophageal cancer were enrolled in the study. Prescription was set to 66 Gy/30 F and 54 Gy/30 F to the primary tumor (PTV66) and subclinical disease (PTV54) . Planning CT (pCT) were segmented into 8 substructures in terms of their differences in physical density, such as gross target volume (GTV), venae cava superior (SVC), aorta, heart, spinal cord, lung, muscle and bones. The pCT and its substructures were transferred to the MIM software to readout their mean HU values. Afterwards, a deformable planning CT to daily KV-CBCT image registration method was then utilized to acquire a new structure set on CBCT. The newly generated structures on CBCT were then transferred back to the treatment planning system (TPS) and its HU information were overridden manually with mean HU values obtained from pCT. Finally, the treatment plan was projected onto the CBCT images with the same beam arrangements and monitor units (MUs) to accomplish dose calculation. Planning target volume (PTV) and organs at risk (OARs) from both of the pCT and CBCT were compared to evaluate the dose calculation accuracy. Results: It was found that the dose distribution in the CBCT showed little differences compared to the pCT, regardless of whether PTV or OARs were concerned. Specifically, dose variation in GTV, PTV54, PTV66, SVC, lung and heart were within 0.1%. The maximum dose variation was presented in the spinal cord, which was up to 2.7% dose difference. Conclusion: The proposed method combined with DIR and ROIM technique to accurately calculate dose distribution on CBCT for esophageal cancer is feasible.

  11. High-Density Electron-Beam Recording of Circumferentially Aligned Dots by Using Substrates with Low Atomic Numbers

    NASA Astrophysics Data System (ADS)

    Okada, Takeru; Aida, Makoto; Fujimori, Jiro; Katsumura, Masahiro; Iida, Tetsuya

    2012-01-01

    Reducing proximity effects is a key factor for achieving a higher resolution in electron-beam lithography and realizing the mastering of patterned media. The effect of substrate materials on backscattering electrons was investigated by simulation and experiment, and resolution enhancement was demonstrated. In Monte Carlo simulations with 100 keV incident electrons, the intensity of backscattering electrons decreased with decreasing atomic number of substrates. On the other hand, both the density of substrates and the existence of 10 nm thin films had negligible effects on the intensity of backscattering electrons. The measured exposure distributions from line-scanned electron beams supported the results of simulations. The intensity of backscattering electrons was reduced by using a carbon substrate, and circumferentially aligned high-density patterns of 878 Gbit/in.2 were resolved.

  12. Apparatus and Method for Focusing a Light Beam in a Three-Dimensional Recording Medium by a Dynamic Holographic Device

    NASA Technical Reports Server (NTRS)

    Juday, Richard D. (Inventor)

    1998-01-01

    An apparatus is disclosed for reading and/or writing information or to from an optical recording medium having a plurality of information storage layers. The apparatus includes a dynamic holographic optical element configured to focus light on the optical recording medium. a control circuit arranged to supply a drive signal to the holographic optical element, and a storage device in communication with the control circuit and storing at least a first drive signal and a second drive signal. The holographic optical element focusses light on a first one of the plurality of information storage layers when driven by the first drive signal on a second one of the plurality of information storage layers when driven by the second drive signal. An optical switch is also disclosed for connecting at least one light source in a source array to at least one light receiver in a receiver array. The switch includes a dynamic holographic optical element configured to receive light from the source array and to transmit light to the receiver array, a control circuit arranged to supply a drive signal to the holographic optical element, and a storage device in communication with the control circuit and storing at least a first drive signal and a second drive signal. The holographic optical element connects a first light source in the source array to a first light receiver in the receiver array when driven by the first drive signal and the holographic optical element connects the first light source with the first light receiver and a second light receiver when driven by the second drive signal.

  13. Pyramid beam splitter

    DOEpatents

    McKeown, Mark H.; Beason, Steven C.; Fairer, George

    1992-01-01

    The apparatus of the present invention provides means for obtaining accurate, dependable, measurement of bearings and directions for geologic mapping in subterranean shafts, such as, for example, nuclear waste storage investigations. In operation, a laser beam is projected along a reference bearing. A pyramid is mounted such that the laser beam is parallel to the pyramid axis and can impinge on the apex of the pyramid thus splitting the beam several ways into several beams at right angles to each other and at right angles to the reference beam. The pyramid is also translatable and rotatable in a plane perpendicular to the reference beam.

  14. Characteristics of microdomains and microdomain patterns recorded by electron beam irradiation on Y-cut LiNbO3 crystals

    NASA Astrophysics Data System (ADS)

    Kokhanchik, L. S.; Gainutdinov, R. V.; Lavrov, S. D.; Volk, T. R.

    2015-08-01

    We present the results of investigations of planar domain patterns (isolated domains and domain gratings) fabricated by irradiation of the nonpolar Y-surface of LiNbO3 crystals by an electron beam (EB) incident normally onto the surface. The EB recorded domains were investigated using atomic force microscopy, confocal second harmonic generation microscopy, and chemical etching as an auxiliary method. The dependence of the domain characteristics on irradiation conditions (acceleration voltage U, EB current I, and irradiation time tirr) were determined. The length Ld of both isolated domains and domain gratings along the polar axis Z grows linearly with tirr (at U, I = const) with no tending to saturation. The plots Ld(tirr) obtained for U = 10 and 15 kV are practically identical, whereas the values of Ld for U = 5 kV are essentially lower. The domain thickness Td along the Y-direction, i.e., the depth of the switched layer grows with acceleration voltage U. These results are discussed in terms of space-charge fields formation arising under EB irradiation of insulators. The linearity of Ld(tirr) is accounted for by the frontal domain growth via the viscous friction law. The experimental dependence of Td on U supports the suggestion that the domain thickness is determined by the penetration depth Re of primary electrons, which in turn is governed by U. The difference in Ld(tirr) plots for different U is accounted for by different electron emission σ. Indirect evidences of a defect structure modification in a thin surface layer with respect to the crystal bulk are obtained.

  15. On numerically accurate finite element

    NASA Technical Reports Server (NTRS)

    Nagtegaal, J. C.; Parks, D. M.; Rice, J. R.

    1974-01-01

    A general criterion for testing a mesh with topologically similar repeat units is given, and the analysis shows that only a few conventional element types and arrangements are, or can be made suitable for computations in the fully plastic range. Further, a new variational principle, which can easily and simply be incorporated into an existing finite element program, is presented. This allows accurate computations to be made even for element designs that would not normally be suitable. Numerical results are given for three plane strain problems, namely pure bending of a beam, a thick-walled tube under pressure, and a deep double edge cracked tensile specimen. The effects of various element designs and of the new variational procedure are illustrated. Elastic-plastic computation at finite strain are discussed.

  16. Beam/seam alignment control for electron beam welding

    DOEpatents

    Burkhardt, Jr., James H.; Henry, J. James; Davenport, Clyde M.

    1980-01-01

    This invention relates to a dynamic beam/seam alignment control system for electron beam welds utilizing video apparatus. The system includes automatic control of workpiece illumination, near infrared illumination of the workpiece to limit the range of illumination and camera sensitivity adjustment, curve fitting of seam position data to obtain an accurate measure of beam/seam alignment, and automatic beam detection and calculation of the threshold beam level from the peak beam level of the preceding video line to locate the beam or seam edges.

  17. The FLUKA Code: An Accurate Simulation Tool for Particle Therapy

    PubMed Central

    Battistoni, Giuseppe; Bauer, Julia; Boehlen, Till T.; Cerutti, Francesco; Chin, Mary P. W.; Dos Santos Augusto, Ricardo; Ferrari, Alfredo; Ortega, Pablo G.; Kozłowska, Wioletta; Magro, Giuseppe; Mairani, Andrea; Parodi, Katia; Sala, Paola R.; Schoofs, Philippe; Tessonnier, Thomas; Vlachoudis, Vasilis

    2016-01-01

    Monte Carlo (MC) codes are increasingly spreading in the hadrontherapy community due to their detailed description of radiation transport and interaction with matter. The suitability of a MC code for application to hadrontherapy demands accurate and reliable physical models capable of handling all components of the expected radiation field. This becomes extremely important for correctly performing not only physical but also biologically based dose calculations, especially in cases where ions heavier than protons are involved. In addition, accurate prediction of emerging secondary radiation is of utmost importance in innovative areas of research aiming at in vivo treatment verification. This contribution will address the recent developments of the FLUKA MC code and its practical applications in this field. Refinements of the FLUKA nuclear models in the therapeutic energy interval lead to an improved description of the mixed radiation field as shown in the presented benchmarks against experimental data with both 4He and 12C ion beams. Accurate description of ionization energy losses and of particle scattering and interactions lead to the excellent agreement of calculated depth–dose profiles with those measured at leading European hadron therapy centers, both with proton and ion beams. In order to support the application of FLUKA in hospital-based environments, Flair, the FLUKA graphical interface, has been enhanced with the capability of translating CT DICOM images into voxel-based computational phantoms in a fast and well-structured way. The interface is capable of importing also radiotherapy treatment data described in DICOM RT standard. In addition, the interface is equipped with an intuitive PET scanner geometry generator and automatic recording of coincidence events. Clinically, similar cases will be presented both in terms of absorbed dose and biological dose calculations describing the various available features. PMID:27242956

  18. The FLUKA Code: An Accurate Simulation Tool for Particle Therapy.

    PubMed

    Battistoni, Giuseppe; Bauer, Julia; Boehlen, Till T; Cerutti, Francesco; Chin, Mary P W; Dos Santos Augusto, Ricardo; Ferrari, Alfredo; Ortega, Pablo G; Kozłowska, Wioletta; Magro, Giuseppe; Mairani, Andrea; Parodi, Katia; Sala, Paola R; Schoofs, Philippe; Tessonnier, Thomas; Vlachoudis, Vasilis

    2016-01-01

    Monte Carlo (MC) codes are increasingly spreading in the hadrontherapy community due to their detailed description of radiation transport and interaction with matter. The suitability of a MC code for application to hadrontherapy demands accurate and reliable physical models capable of handling all components of the expected radiation field. This becomes extremely important for correctly performing not only physical but also biologically based dose calculations, especially in cases where ions heavier than protons are involved. In addition, accurate prediction of emerging secondary radiation is of utmost importance in innovative areas of research aiming at in vivo treatment verification. This contribution will address the recent developments of the FLUKA MC code and its practical applications in this field. Refinements of the FLUKA nuclear models in the therapeutic energy interval lead to an improved description of the mixed radiation field as shown in the presented benchmarks against experimental data with both (4)He and (12)C ion beams. Accurate description of ionization energy losses and of particle scattering and interactions lead to the excellent agreement of calculated depth-dose profiles with those measured at leading European hadron therapy centers, both with proton and ion beams. In order to support the application of FLUKA in hospital-based environments, Flair, the FLUKA graphical interface, has been enhanced with the capability of translating CT DICOM images into voxel-based computational phantoms in a fast and well-structured way. The interface is capable of importing also radiotherapy treatment data described in DICOM RT standard. In addition, the interface is equipped with an intuitive PET scanner geometry generator and automatic recording of coincidence events. Clinically, similar cases will be presented both in terms of absorbed dose and biological dose calculations describing the various available features.

  19. Accurate determination of optical bandgap and lattice parameters of Zn{sub 1-x}Mg{sub x}O epitaxial films (0{<=}x{<=}0.3) grown by plasma-assisted molecular beam epitaxy on a-plane sapphire

    SciTech Connect

    Laumer, Bernhard; Schuster, Fabian; Stutzmann, Martin; Bergmaier, Andreas; Dollinger, Guenther; Eickhoff, Martin

    2013-06-21

    Zn{sub 1-x}Mg{sub x}O epitaxial films with Mg concentrations 0{<=}x{<=}0.3 were grown by plasma-assisted molecular beam epitaxy on a-plane sapphire substrates. Precise determination of the Mg concentration x was performed by elastic recoil detection analysis. The bandgap energy was extracted from absorption measurements with high accuracy taking electron-hole interaction and exciton-phonon complexes into account. From these results a linear relationship between bandgap energy and Mg concentration is established for x{<=}0.3. Due to alloy disorder, the increase of the photoluminescence emission energy with Mg concentration is less pronounced. An analysis of the lattice parameters reveals that the epitaxial films grow biaxially strained on a-plane sapphire.

  20. Accurate Alignment of Plasma Channels Based on Laser Centroid Oscillations

    SciTech Connect

    Gonsalves, Anthony; Nakamura, Kei; Lin, Chen; Osterhoff, Jens; Shiraishi, Satomi; Schroeder, Carl; Geddes, Cameron; Toth, Csaba; Esarey, Eric; Leemans, Wim

    2011-03-23

    A technique has been developed to accurately align a laser beam through a plasma channel by minimizing the shift in laser centroid and angle at the channel outptut. If only the shift in centroid or angle is measured, then accurate alignment is provided by minimizing laser centroid motion at the channel exit as the channel properties are scanned. The improvement in alignment accuracy provided by this technique is important for minimizing electron beam pointing errors in laser plasma accelerators.

  1. BEAM-BEAM 2003 SUMMARY.

    SciTech Connect

    FISCHER,W.SEN,T.

    2003-05-19

    This paper summarizes the presentations and discussions of the Beam-Beam'03 workshop, held in Montauk, Long Island, from May 19 to 23, 2003. Presentations and discussions focused on halo generation from beam-beam interactions; beam-beam limits, especially coherent limits and their effects on existing and future hadron colliders; beam-beam compensation techniques, particularly for long-range interactions; and beam-beam study tools in theory, simulation, and experiment.

  2. An Accurate, Simplified Model Intrabeam Scattering

    SciTech Connect

    Bane, Karl LF

    2002-05-23

    Beginning with the general Bjorken-Mtingwa solution for intrabeam scattering (IBS) we derive an accurate, greatly simplified model of IBS, valid for high energy beams in normal storage ring lattices. In addition, we show that, under the same conditions, a modified version of Piwinski's IBS formulation (where {eta}{sub x,y}{sup 2}/{beta}{sub x,y} has been replaced by {Eta}{sub x,y}) asymptotically approaches the result of Bjorken-Mtingwa.

  3. Statistical analysis of accurate prediction of local atmospheric optical attenuation with a new model according to weather together with beam wandering compensation system: a season-wise experimental investigation

    NASA Astrophysics Data System (ADS)

    Arockia Bazil Raj, A.; Padmavathi, S.

    2016-07-01

    Atmospheric parameters strongly affect the performance of Free Space Optical Communication (FSOC) system when the optical wave is propagating through the inhomogeneous turbulent medium. Developing a model to get an accurate prediction of optical attenuation according to meteorological parameters becomes significant to understand the behaviour of FSOC channel during different seasons. A dedicated free space optical link experimental set-up is developed for the range of 0.5 km at an altitude of 15.25 m. The diurnal profile of received power and corresponding meteorological parameters are continuously measured using the developed optoelectronic assembly and weather station, respectively, and stored in a data logging computer. Measured meteorological parameters (as input factors) and optical attenuation (as response factor) of size [177147 × 4] are used for linear regression analysis and to design the mathematical model that is more suitable to predict the atmospheric optical attenuation at our test field. A model that exhibits the R2 value of 98.76% and average percentage deviation of 1.59% is considered for practical implementation. The prediction accuracy of the proposed model is investigated along with the comparative results obtained from some of the existing models in terms of Root Mean Square Error (RMSE) during different local seasons in one-year period. The average RMSE value of 0.043-dB/km is obtained in the longer range dynamic of meteorological parameters variations.

  4. Accurate Finite Difference Algorithms

    NASA Technical Reports Server (NTRS)

    Goodrich, John W.

    1996-01-01

    Two families of finite difference algorithms for computational aeroacoustics are presented and compared. All of the algorithms are single step explicit methods, they have the same order of accuracy in both space and time, with examples up to eleventh order, and they have multidimensional extensions. One of the algorithm families has spectral like high resolution. Propagation with high order and high resolution algorithms can produce accurate results after O(10(exp 6)) periods of propagation with eight grid points per wavelength.

  5. Accurate monotone cubic interpolation

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1991-01-01

    Monotone piecewise cubic interpolants are simple and effective. They are generally third-order accurate, except near strict local extrema where accuracy degenerates to second-order due to the monotonicity constraint. Algorithms for piecewise cubic interpolants, which preserve monotonicity as well as uniform third and fourth-order accuracy are presented. The gain of accuracy is obtained by relaxing the monotonicity constraint in a geometric framework in which the median function plays a crucial role.

  6. Computerized mega code recording.

    PubMed

    Burt, T W; Bock, H C

    1988-04-01

    A system has been developed to facilitate recording of advanced cardiac life support mega code testing scenarios. By scanning a paper "keyboard" using a bar code wand attached to a portable microcomputer, the person assigned to record the scenario can easily generate an accurate, complete, timed, and typewritten record of the given situations and the obtained responses.

  7. Beam-beam simulations for separated beams

    SciTech Connect

    Furman, Miguel A.

    2000-04-10

    We present beam-beam simulation results from a strong-strong gaussian code for separated beams for the LHC and RHIC. The frequency spectrum produced by the beam-beam collisions is readily obtained and offers a good opportunity for experimental comparisons. Although our results for the emittance blowup are preliminary, we conclude that, for nominal parameter values, there is no significant difference between separated beams and center-on-center collisions.

  8. Quantitative high dynamic range beam profiling for fluorescence microscopy

    SciTech Connect

    Mitchell, T. J. Saunter, C. D.; O’Nions, W.; Girkin, J. M.; Love, G. D.

    2014-10-15

    Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

  9. Accurate quantum chemical calculations

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Langhoff, Stephen R.; Taylor, Peter R.

    1989-01-01

    An important goal of quantum chemical calculations is to provide an understanding of chemical bonding and molecular electronic structure. A second goal, the prediction of energy differences to chemical accuracy, has been much harder to attain. First, the computational resources required to achieve such accuracy are very large, and second, it is not straightforward to demonstrate that an apparently accurate result, in terms of agreement with experiment, does not result from a cancellation of errors. Recent advances in electronic structure methodology, coupled with the power of vector supercomputers, have made it possible to solve a number of electronic structure problems exactly using the full configuration interaction (FCI) method within a subspace of the complete Hilbert space. These exact results can be used to benchmark approximate techniques that are applicable to a wider range of chemical and physical problems. The methodology of many-electron quantum chemistry is reviewed. Methods are considered in detail for performing FCI calculations. The application of FCI methods to several three-electron problems in molecular physics are discussed. A number of benchmark applications of FCI wave functions are described. Atomic basis sets and the development of improved methods for handling very large basis sets are discussed: these are then applied to a number of chemical and spectroscopic problems; to transition metals; and to problems involving potential energy surfaces. Although the experiences described give considerable grounds for optimism about the general ability to perform accurate calculations, there are several problems that have proved less tractable, at least with current computer resources, and these and possible solutions are discussed.

  10. BEAM LIFETIME AND EMITTANCE GROWTH MEASUREMENTS OF GOLD BEAMS IN RHIC AT STORAGE.

    SciTech Connect

    FISCHER,W.; DREES,A.; BRENNAN,J.M.; CONNOLLY,R.; FLILLER,R.; TEPIKIAN,S.; VAN ZEIJTS,J.

    2001-06-18

    During stores of gold beams, longitudinal and transverse beam sizes were recorded. Longitudinal profiles were obtained with a wall current monitor. Transverse profiles were reconstructed from gold-gold collision rates at various relative transverse beam positions. The total beam lifetime was measured with a beam current transformer, the bunched beam lifetime with the wall current monitor. Diffusion rates in the beam halo were determined from the change in the loss rate when a scraper is retracted. The measurements are used to determine the lifetime limiting effects. Beam growth measurements are compared with computations of beam-growth times from intra-beam scattering.

  11. Characterization of electron-beam recorded microdomain patterns on the nonpolar surface of LiNbO3 crystal by nondestructive methods

    NASA Astrophysics Data System (ADS)

    Kokhanchik, L. S.; Gainutdinov, R. V.; Mishina, E. D.; Lavrov, S. D.; Volk, T. R.

    2014-10-01

    We report on characterization of the electron-beam fabricated planar domain gratings on the nonpolar (Y-) surface of LiNbO3 crystals performed with the use of AFM and confocal second harmonic generation (SHG) microscopy. The dependence of domain formation on the irradiation conditions was investigated. The relation of domain thicknesses to the electron penetration depth is experimentally proved. In particular, the possibility of controlling the thickness of planar domains by varying acceleration electron-beam voltages is demonstrated. The observed specificity of SHG is analyzed in the framework of the Kleinman-Boyd theory [G. D. Boyd and D. A. Kleinman, J. Appl. Phys. 39, 3597 (1968)] and Uesu approach [Kaneshiro et al., J. Appl. Phys. 104, 054112 (2008); Kaneshiro et al., J. Opt. Soc. Am. B 27, 888 (2010)] extended in our case to reflection geometry. The calculations performed predict the dependence of SHG conversion efficiency η on the domain thickness, which is in a qualitative agreement with the experiment. It is shown that planar domains on top of the nonpolar surface always enhance the value of η as compared with the bare surface.

  12. BIOACCESSIBILITY TESTS ACCURATELY ESTIMATE ...

    EPA Pesticide Factsheets

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from five Pb-contaminated Superfund sites had relative bioavailabilities from 33%-63%, with a mean of about 50%. Treatment of two of the soils with P significantly reduced the bioavailability of Pb. The bioaccessibility of the Pb in the test soils was then measured in six in vitro tests and regressed on bioavailability. They were: the “Relative Bioavailability Leaching Procedure” (RBALP) at pH 1.5, the same test conducted at pH 2.5, the “Ohio State University In vitro Gastrointestinal” method (OSU IVG), the “Urban Soil Bioaccessible Lead Test”, the modified “Physiologically Based Extraction Test” and the “Waterfowl Physiologically Based Extraction Test.” All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the RBALP pH 2.5 and OSU IVG tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter 24%, or present as Pb sulfate 18%. Ad

  13. Accurate spectral color measurements

    NASA Astrophysics Data System (ADS)

    Hiltunen, Jouni; Jaeaeskelaeinen, Timo; Parkkinen, Jussi P. S.

    1999-08-01

    Surface color measurement is of importance in a very wide range of industrial applications including paint, paper, printing, photography, textiles, plastics and so on. For a demanding color measurements spectral approach is often needed. One can measure a color spectrum with a spectrophotometer using calibrated standard samples as a reference. Because it is impossible to define absolute color values of a sample, we always work with approximations. The human eye can perceive color difference as small as 0.5 CIELAB units and thus distinguish millions of colors. This 0.5 unit difference should be a goal for the precise color measurements. This limit is not a problem if we only want to measure the color difference of two samples, but if we want to know in a same time exact color coordinate values accuracy problems arise. The values of two instruments can be astonishingly different. The accuracy of the instrument used in color measurement may depend on various errors such as photometric non-linearity, wavelength error, integrating sphere dark level error, integrating sphere error in both specular included and specular excluded modes. Thus the correction formulas should be used to get more accurate results. Another question is how many channels i.e. wavelengths we are using to measure a spectrum. It is obvious that the sampling interval should be short to get more precise results. Furthermore, the result we get is always compromise of measuring time, conditions and cost. Sometimes we have to use portable syste or the shape and the size of samples makes it impossible to use sensitive equipment. In this study a small set of calibrated color tiles measured with the Perkin Elmer Lamda 18 and the Minolta CM-2002 spectrophotometers are compared. In the paper we explain the typical error sources of spectral color measurements, and show which are the accuracy demands a good colorimeter should have.

  14. FAS 33: accurately recording effects of changing prices.

    PubMed

    Sage, L G

    1987-02-01

    FAS 33 addresses the problem of distortion in conventional historical cost financial statements because of changing prices. It requires 1300 business enterprises to report selected changing price data on a supplementary basis. It has been demonstrated that it is also feasible and beneficial for hospitals to present price disclosures as supplementary information to their financial statements. The possible application of FAS 33 is supported on the basis that the accounting and reporting methods of healthcare institutions are similar to the accounting and reporting practices of profit-seeking entities.

  15. Cartesian beams.

    PubMed

    Bandres, Miguel A; Gutiérrez-Vega, Julio C

    2007-12-01

    A new and very general beam solution of the paraxial wave equation in Cartesian coordinates is presented. We call such a field a Cartesian beam. The complex amplitude of the Cartesian beams is described by either the parabolic cylinder functions or the confluent hypergeometric functions, and the beams are characterized by three parameters that are complex in the most general situation. The propagation through complex ABCD optical systems and the conditions for square integration are studied in detail. Applying the general expression of the Cartesian beams, we also derive two new and meaningful beam structures that, to our knowledge, have not yet been reported in the literature. Special cases of the Cartesian beams are the standard, elegant, and generalized Hermite-Gauss beams, the cosine-Gauss beams, the Lorentz beams, and the fractional order beams.

  16. The compensation of the PC beam of the scattered beam by a foam target with FWM for beam steering

    NASA Astrophysics Data System (ADS)

    Kameyama, Nobukazu; Yoshida, Hiroki

    2012-10-01

    It is necessary for the direct IFE to irradiate a target with laser beams. The laser beams have to be steered for accurate laser irradiation since the target is injected at several hundreds meters per second. The method of beam steering with phase conjugate mirrors is one of the candidates. In the method, probe beams whose energies are low enough not to damage it and expanded larger than the target radius are illuminated the target. The scattered beam enters into the phase conjugate mirrors and the phase conjugate beam is generated in the opposite direction of it. The phase conjugate beam retraces the same path for the property and irradiated the target. As the target has moved several hundreds micrometers for the high speed when the phase conjugate beam comes back, it is necessary for the phase conjugate beam to compensate for accurate irradiation. Four wave mixing is used as the compensation way. The interaction of two counter-propagating pump beams and a seed beam generates a phase conjugate beam in four wave mixing. The phase conjugate beam is adjustable by setting the angle between two pump beams. The compensation with a scattered beam by a foam target as a seed beam is reported.

  17. Thermographic calorimetry of the neutral beam injectors heating beams at TJ-II

    SciTech Connect

    Fuentes, C.; Liniers, M.; Guasp, J.; Doncel, J.; Botija, J.; Wolfers, G.; Alonso, J.; Acedo, M.; Sanchez, E.; Marcon, G.; Weber, M.; Carrasco, R.; Sarasola, X.; Zurro, B.; Tera, J.

    2006-10-15

    A new beam diagnostic based on infrared thermography has been developed for the neutral beam injectors of the stellarator TJ-II. A highly anisotropic movable target intercepts the beam at its entrance into the stellarator. The thermal print of the beam is captured with a high resolution infrared camera. The infrared images of the target can be translated, with the appropriate analysis, into power density patterns of the beam. The system is calibrated in situ with two thermocouples adiabatically mounted in the target. The two-dimensional beam power density distribution can be accurately characterized allowing beam optimization with respect to the different parameters involved in the beam formation and transport.

  18. Dual-beam mastering for advanced formats

    NASA Astrophysics Data System (ADS)

    Verhaart, Gerarous J.; Stockx, Harry; Wijn, Josephus M.; Yoon, Du-Seop

    1996-09-01

    A dual beam recorder for high density format has been developed. The recorder features remote control of size and mutual distance of both recording spots, a special beam pointing control system, and a high accuracy, laser interferometer controlled, radial drive. The recorder can switch between very dissimilar formats without intermediate alignment. The performance of the recorder has been shown for DVD, MO, and even higher density formats. Track pitches down to 0.7 micrometers have been realized.

  19. Recent advances of strong-strong beam-beam simulation

    SciTech Connect

    Qiang, Ji; Furman, Miguel A.; Ryne, Robert D.; Fischer, Wolfram; Ohmi,Kazuhito

    2004-09-15

    In this paper, we report on recent advances in strong-strong beam-beam simulation. Numerical methods used in the calculation of the beam-beam forces are reviewed. A new computational method to solve the Poisson equation on nonuniform grid is presented. This method reduces the computational cost by a half compared with the standard FFT based method on uniform grid. It is also more accurate than the standard method for a colliding beam with low transverse aspect ratio. In applications, we present the study of coherent modes with multi-bunch, multi-collision beam-beam interactions at RHIC. We also present the strong-strong simulation of the luminosity evolution at KEKB with and without finite crossing angle.

  20. Algorithm for X-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam CT.

    PubMed

    Maltz, Jonathan S; Gangadharan, Bijumon; Bose, Supratik; Hristov, Dimitre H; Faddegon, Bruce A; Paidi, Ajay; Bani-Hashemi, Ali R

    2008-12-01

    Quantitative reconstruction of cone beam X-ray computed tomography (CT) datasets requires accurate modeling of scatter, beam-hardening, beam profile, and detector response. Typically, commercial imaging systems use fast empirical corrections that are designed to reduce visible artifacts due to incomplete modeling of the image formation process. In contrast, Monte Carlo (MC) methods are much more accurate but are relatively slow. Scatter kernel superposition (SKS) methods offer a balance between accuracy and computational practicality. We show how a single SKS algorithm can be employed to correct both kilovoltage (kV) energy (diagnostic) and megavoltage (MV) energy (treatment) X-ray images. Using MC models of kV and MV imaging systems, we map intensities recorded on an amorphous silicon flat panel detector to water-equivalent thicknesses (WETs). Scattergrams are derived from acquired projection images using scatter kernels indexed by the local WET values and are then iteratively refined using a scatter magnitude bounding scheme that allows the algorithm to accommodate the very high scatter-to-primary ratios encountered in kV imaging. The algorithm recovers radiological thicknesses to within 9% of the true value at both kV and megavolt energies. Nonuniformity in CT reconstructions of homogeneous phantoms is reduced by an average of 76% over a wide range of beam energies and phantom geometries.

  1. Differential equation based method for accurate approximations in optimization

    NASA Technical Reports Server (NTRS)

    Pritchard, Jocelyn I.; Adelman, Howard M.

    1990-01-01

    A method to efficiently and accurately approximate the effect of design changes on structural response is described. The key to this method is to interpret sensitivity equations as differential equations that may be solved explicitly for closed form approximations, hence, the method is denoted the Differential Equation Based (DEB) method. Approximations were developed for vibration frequencies, mode shapes and static displacements. The DEB approximation method was applied to a cantilever beam and results compared with the commonly-used linear Taylor series approximations and exact solutions. The test calculations involved perturbing the height, width, cross-sectional area, tip mass, and bending inertia of the beam. The DEB method proved to be very accurate, and in most cases, was more accurate than the linear Taylor series approximation. The method is applicable to simultaneous perturbation of several design variables. Also, the approximations may be used to calculate other system response quantities. For example, the approximations for displacements are used to approximate bending stresses.

  2. High power beam analysis

    NASA Astrophysics Data System (ADS)

    Aharon, Oren

    2014-02-01

    In various modern scientific and industrial laser applications, beam-shaping optics manipulates the laser spot size and its intensity distribution. However the designed laser spot frequently deviates from the design goal due to real life imperfections and effects, such as: input laser distortions, optical distortion, heating, overall instabilities, and non-linear effects. Lasers provide the ability to accurately deliver large amounts of energy to a target area with very high accuracy. Thus monitoring beam size power and beam location is of high importance for high quality results and repeatability. Depending on the combination of wavelength, beam size and pulse duration , laser energy is absorbed by the material surface, yielding into processes such as cutting, welding, surface treatment, brazing and many other applications. This article will cover the aspect of laser beam measurements, especially at the focal point where it matters the most. A brief introduction to the material processing interactions will be covered, followed by fundamentals of laser beam propagation, novel measurement techniques, actual measurement and brief conclusions.

  3. Accurate Evaluation of Quantum Integrals

    NASA Technical Reports Server (NTRS)

    Galant, D. C.; Goorvitch, D.; Witteborn, Fred C. (Technical Monitor)

    1995-01-01

    Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schrodinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

  4. Beam diagnostics

    SciTech Connect

    Bogaty, J.; Clifft, B.E.; Zinkann, G.P.; Pardo, R.C.

    1995-08-01

    The ECR-PII injector beam line is operated at a fixed ion velocity. The platform high voltage is chosen so that all ions have a velocity of 0.0085c at the PII entrance. If a previous tune configuration for the linac is to be used, the beam arrival time must be matched to the previous tune as well. A nondestructive beam-phase pickup detector was developed and installed at the entrance to the PII linac. This device provides continuous phase and beam current information and allows quick optimization of the beam injected into PII. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum interface where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam-induced radiofrequency signals are summed against an offset frequency generated by our master oscillator. The resulting kilohertz difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop which stabilizes phase readings if beam is unstable. The other channel uses a linear full wave active rectifier circuit which converts kilohertz sine wave signal amplitude to a D.C. voltage representing beam current. A prototype set of electronics is now in use with the detector and we began to use the system in operation to set the arrival beam phase. A permanent version of the electronics system for the phase detector is now under construction. Additional nondestructive beam intensity and phase monitors at the {open_quotes}Booster{close_quotes} and {open_quotes}ATLAS{close_quotes} linac sections are planned as well as on some of the high-energy beam lines. Such a monitor will be particularly useful for FMA experiments where the primary beam hits one of the electric deflector plates.

  5. Verification procedure for isocentric alignment of proton beams.

    PubMed

    Ciangaru, George; Yang, James N; Oliver, Patrick J; Bues, Martin; Zhu, Mengping; Nakagawa, Fumio; Chiba, Hitoshi; Nakamura, Shin; Yoshino, Hirofumi; Umezawa, Mosumi; Smith, Alfred R

    2007-10-24

    We present a technique--based on the Lutz, Winston, and Maleki test used in stereotactic linear accelerator radiosurgery--for verifying whether proton beams are being delivered within the required spatial coincidence with the gantry mechanical isocenter. Our procedure uses a proton beam that is collimated by a circular aperture at its central axis and is then intercepted by a small steel sphere rigidly supported by the patient couch. A laser tracker measurement system and a correction algorithm for couch position assures precise positioning of the steel sphere at the mechanical isocenter of the gantry. A film-based radiation dosimetry technique, chosen for the good spatial resolution it achieves, records the proton dose distribution for optical image analysis. The optical image obtained presents a circular high-dose region surrounding a lower-dose area corresponding to the proton beam absorption by the steel sphere, thereby providing a measure of the beam alignment with the mechanical isocenter. We found the self-developing Gafchromic EBT film (International Specialty Products, Wayne, NJ) and commercial Epson 10000 XL flatbed scanner (Epson America, Long Beach, CA) to be accurate and efficient tools. The positions of the gantry mechanical and proton beam isocenters, as recorded on film, were clearly identifiable within the scanning resolution used for routine alignment testing (0.17 mm per pixel). The mean displacement of the collimated proton beam from the gantry mechanical isocenter was 0.22 +/- 0.1 mm for the gantry positions tested, which was well within the maximum deviation of 0.50 mm accepted at the Proton Therapy Center in Houston.

  6. 21 CFR 812.140 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Records. 812.140 Section 812.140 Food and Drugs... INVESTIGATIONAL DEVICE EXEMPTIONS Records and Reports § 812.140 Records. (a) Investigator records. A participating investigator shall maintain the following accurate, complete, and current records relating to the...

  7. 21 CFR 812.140 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Records. 812.140 Section 812.140 Food and Drugs... INVESTIGATIONAL DEVICE EXEMPTIONS Records and Reports § 812.140 Records. (a) Investigator records. A participating investigator shall maintain the following accurate, complete, and current records relating to the...

  8. Vectorial complex-source vortex beams

    NASA Astrophysics Data System (ADS)

    Orlov, S.; Banzer, P.

    2014-08-01

    The scalar complex source vortex model is an accurate description of highly focused scalar vortices. We use it to construct a variety of vectorial solutions of Maxwell's equations describing highly focused and variously polarized vector vortex beams accurately. Three different families of optical vector vortex beams are presented and studied in detail. In this model, optical vortices derived within Cartesian symmetry correspond to circularly and linearly polarized highly focused vortex beams in the focus of a high numerical aperture focusing system. In addition, we report on vortical complex-source beams derived within cylindrical and spherical symmetries which exhibit very special and intriguing properties.

  9. How accurate are antenatal weight measurements? A survey of hospital and community clinics in a South Thames Region NHS Trust.

    PubMed

    Harris, H E; Ellison, G T; Holliday, M; Nickson, C

    1998-04-01

    The accuracy of antenatal weight data recorded in obstetric notes was investigated in the 45 hospital and community antenatal clinics within a South Thames Region NHS Trust. In order to assess the reliability and validity of all 60 clinic scales triplicate measurements of body weight for low- and high-weight subjects were recorded on each clinical scale and on a calibrated standard scale. The quality of weighing practice during antenatal care was investigated by means of semi-structured interviews conducted with all 33 midwives who currently provide antenatal care within the Trust. Beam balances had the highest reliability and validity, whereas scales with spring mechanisms were the least accurate. Only 40% of the clinics surveyed had access to beam balances, yet most of the maternal weight measurements recorded during antenatal care are likely to be out by no more than 1-1.5% of body weight. Weighing practice was generally inconsistent, and serial measurements of maternal body weight collected during pregnancy are probably too imprecise to provide a sensitive screen for conditions associated with unusual weight gain and too inaccurate to assess compliance with guidelines for weight gain.

  10. Cine recording ophthalmoscope

    NASA Technical Reports Server (NTRS)

    Fitzgerald, J. W.

    1972-01-01

    Camera system provides accurate photographic recording during acceleration of centrifuge and permits immediate observation of dynamic changes in retinal circulation by a closed-circuit television loop. System consists of main camera, remote control unit, and strobe power supply unit, and is used for fluorescein studies and dynamometry sequences.

  11. Accurate measurement method of Fabry-Perot cavity parameters via optical transfer function

    SciTech Connect

    Bondu, Francois; Debieu, Olivier

    2007-05-10

    It is shown how the transfer function from frequency noise to a Pound-Drever-Hall signal for a Fabry-Perot cavity can be used to accurately measure cavity length, cavity linewidth, mirror curvature, misalignments, laser beam shape mismatching with resonant beam shape, and cavity impedance mismatching with respect to vacuum.

  12. Beam characteristics of megavoltage beams at low monitor unit settings.

    PubMed

    Kemikler, G; Acun, H

    2011-10-01

    Beam characteristics of a linear accelerator are of great importance for intensity-modulated radiation therapy (IMRT) to ensure precise and accurate dose delivery to patients. In step-and-shoot IMRT, each beam is delivered through a series of small, segmented fields at low monitor unit (MU) settings. In this study, the beam characteristics of both static (ST) and segmental intensity-modulated (IM) beams were investigated at various dose rates for 6 and 18 MV at low MU settings. Dose linearity was investigated for both the ST and the IM beams. For the ST beams, standard 10 × 10 cm(2) fields were irradiated with MU values ranging from 1 to 100. For the IM beams, 10 × 10 cm(2) and 15 × 15 cm(2) fields were used as subfields. The normalized dose (ND)/MU was obtained. Beam flatness and symmetry for 2 and 10 MU was measured by in-plane (G-T) and cross-plane (R-L) profiles using Kodak XV films. The largest dose/MU discrepancies were observed for 1 MU. For the ST beams, the beam output decreased up to 4.5% for 1 MU at the high dose rates of 6 and 18 MV. Dose variations were less than 1% for doses above 5 MU. No significant variation was observed in the beam profiles of the ST and the IM groups. Beam flatness and symmetry were close to 3% and 2% for 6 and 18 MV, respectively. Our results showed that dose linearity and delivery errors were close to 1% for doses above 5 MU, which is considered acceptable for both 6- and 18-MV ST and IM therapy.

  13. Beam-energy inequality in the beam-beam interaction

    SciTech Connect

    Krishnagopal, S.; Siemann, R. )

    1990-03-01

    Conditions for energy transparency,'' unequal-energy beams having the same beam-beam behavior, are derived for round beams from a Hamiltonian model of the beam-beam interaction. These conditions are equal fractional betatron tunes, equal synchrotron tunes, equal beam-beam strength parameters, equal nominal sizes, equal {beta}{sup *}'s and equal bunch lengths. With these conditions the only way to compensate for unequal energies is with the number of particles per bunch.

  14. 7 CFR 982.471 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE HAZELNUTS GROWN IN OREGON AND... accurate records showing the receipt, shipment and sale of all hazelnuts handled, used or otherwise... also maintain a current record of all hazelnuts held in inventory....

  15. 7 CFR 982.471 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE HAZELNUTS GROWN IN OREGON AND... accurate records showing the receipt, shipment and sale of all hazelnuts handled, used or otherwise... also maintain a current record of all hazelnuts held in inventory....

  16. Magnetic Recording.

    ERIC Educational Resources Information Center

    Lowman, Charles E.

    A guide to the technology of magnetic recorders used in such fields as audio recording, broadcast and closed-circuit television, instrumentation recording, and computer data systems is presented. Included are discussions of applications, advantages, and limitations of magnetic recording, its basic principles and theory of operation, and its…

  17. Note: Fast, small, accurate 90° rotator for a polarizer.

    PubMed

    Shelton, David P; O'Donnell, William M; Norton, James L

    2011-03-01

    A permanent magnet stepper motor is modified to hold a dichroic polarizer inside the motor. Rotation of the polarizer by 90° ± 0.04° is accomplished within 80 ms. This device is used for measurements of the intensity ratio for two orthogonal linear polarized components of a light beam. The two selected polarizations can be rapidly alternated to allow for signal drift compensation, and the two selected polarizations are accurately orthogonal.

  18. Digital optical recorder-reproducer system

    NASA Technical Reports Server (NTRS)

    Reddersen, Brad R. (Inventor); Zech, Richard G. (Inventor); Roberts, Howard N. (Inventor)

    1980-01-01

    A mass archival optical recording and reproduction system includes a recording light source such as a laser beam focussed and directed upon an acousto-optic linear modulator array (or page composer) that receives parallel blocks of data converted from a serial stream of digital data to be stored. The page composer imparts to the laser beam modulation representative of a plurality of parallel channels of data and through focussing optics downstream of the page composer parallel arrays of optical spots are recorded upon a suitable recording medium such as a photographic film floppy disc. The recording medium may be substantially frictionlessly and stably positioned for recording at a record/read station by an air-bearing platen arrangement which is preferably thermodynamically non-throttling so that the recording film may be positioned in the path of the information-carrying light beam in a static or dynamic mode. During readout, the page composer is bypassed and a readout light beam is focussed directly upon the recording medium containing an array of previously recorded digital spots, a sync bit, data positioning bits, and a tracking band. The readout beam which has been directed through the recording medium is then imaged upon a photodetector array, the output of which may be coupled to suitable electronic processing circuitry, such as a digital multiplexer, whereby the parallel spot array is converted back into the original serial data stream.

  19. Infrared Risley beam pointer

    NASA Astrophysics Data System (ADS)

    Harford, Steven T.; Gutierrez, Homero; Newman, Michael; Pierce, Robert; Quakenbush, Tim; Wallace, John; Bornstein, Michael

    2014-03-01

    Ball Aerospace & Technologies Corp. (BATC) has developed a Risley Beam Pointer (RBP) mechanism capable of agile slewing, accurate pointing and high bandwidth. The RBP is comprised of two wedged prisms that offer a wide Field of Regard (FOR) and may be manufactured and operated with diffraction limited optical quality. The tightly packaged mechanism is capable of steering a 4 inch beam over a 60° half angle cone with better than 60 μrad precision. Absolute accuracy of the beam steering is better than 1 mrad. The conformal nature of the RBP makes it an ideal mechanism for use on low altitude aircraft and unmanned aerial vehicles. Unique aspects of the opto-mechanical design include i) thermal compliance to maintain bearing preload and optical figure over a wide temperature range; and ii) packaging of a remote infrared sensor that periodically reports the temperature of both prisms for accurate determination of the index of refraction. The pointing control system operates each prism independently and employs an inner rate loop nested within an outer position loop. Mathematics for the transformation between line-of-sight coordinates and prism rotation are hosted on a 200 MHz microcontroller with just 516 KB of RAM.

  20. Beam tuning

    SciTech Connect

    Pardo, R.C.; Zinkann, G.P.

    1995-08-01

    A program for configuring the linac, based on previously run configurations for any desired beam was used during the past year. This program uses only a small number of empirical tunes to scale resonator fields to properly accelerate a beam with a different charge-to-mass (q/A) ratio from the original tune configuration. The program worked very well for the PII linac section where we can easily match a new beam`s arrival phase and velocity to the tuned value. It was also fairly successful for the Booster and ATLAS sections of the linac, but not as successful as for the PII linac. Most of the problems are associated with setting the beam arrival time correctly for each major linac section. This problem is being addressed with the development of the capacitive pickup beam phase monitor discussed above. During the next year we expect to improve our ability to quickly configure the linac for new beams and reduce the time required for linac tuning. Already the time required for linac tuning as a percentage of research hours has decreased from 22% in FY 1993 to 15% in the first quarter of FY 1995.

  1. Cylindrical diffractive lenses recorded on PVA/AA photopolymers

    NASA Astrophysics Data System (ADS)

    Fernández, R.; Gallego, S.; Márquez, A.; Navarro-Fuster, V.; Francés, J.; Neipp, C.; Beléndez, A.; Pascual, I.

    2016-04-01

    Photopolymers are optical recording materials appealing for many different applications such as holography, data storage, interconnectors, solar concentrations, or wave-guides fabrication. Recently the capacity of photopolymers to record diffractive optical elements (DOE's) has been investigated. Different authors have reported proposes to record DOE like fork gratings, photonics structures, lenses, sinusoidal, blazed or fork gratings. In these experiments there are different experimental set-ups and different photopolymers. In this work due to the improvement in the spatial light modulation technology together with the photopolymer science we propose a recording experimental system of DOE using a Liquid Cristal based on Silicon (LCoS) display as a master to store complex DOE like cylindrical lenses. This technology permits us an accurate control of the phase and the amplitude of the recording beam, with a very small pixel size. The main advantage of this display is that permit us to modify the DOE automatically, we use the software of the LCoS to send the voltage to each pixel In this work we use a photopolymer composed by acrylamide (AA) as polymerizable monomer and polyvinyl alcohol (PVA). We use a coverplated and index matched photopolymer to avoid the influence of the thickness variation on the transmitted light. In order to reproduce the material behaviour during polymerization, we have designed our model to simulate cylindrical lenses and used Fresnel propagation to simulate the light propagation through the DOE and analyze the focal plane and the properties of the recorded lenses.

  2. Complex source beam: A tool to describe highly focused vector beams analytically

    SciTech Connect

    Orlov, S.; Peschel, U.

    2010-12-15

    The scalar-complex-source model is used to develop an accurate description of highly focused radially, azimuthally, linearly, and circularly polarized monochromatic vector beams. We investigate the power and full beam widths at half maximum of vigorous Maxwell equation solutions. The analytical expressions are employed to compare the vector complex source beams with the real beams produced by various high-numerical-aperture (NA) focusing systems. We find a parameter set for which the spatial extents of the analytical beams are the same as those of experimentally realized ones. We ensure the same shape of the considered beams by investigating an overlap of the complex source beams with high-NA beams. We demonstrate that the analytical expressions are good approximations for realistic highly focused beams.

  3. 7 CFR 989.176 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Records. 989.176 Section 989.176 Agriculture... CALIFORNIA Administrative Rules and Regulations Reports and Records § 989.176 Records. Each handler shall maintain complete, accurate, and current records of all of his business affairs concerning which he...

  4. 27 CFR 22.161 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Records. 22.161 Section 22... TREASURY LIQUORS DISTRIBUTION AND USE OF TAX-FREE ALCOHOL Records of Transactions § 22.161 Records. (a) General. All persons qualified under this part shall keep accurate records of all receipts,...

  5. 27 CFR 22.161 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Records. 22.161 Section 22... TREASURY ALCOHOL DISTRIBUTION AND USE OF TAX-FREE ALCOHOL Records of Transactions § 22.161 Records. (a) General. All persons qualified under this part shall keep accurate records of all receipts,...

  6. 27 CFR 53.24 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2013-04-01 2013-04-01 false Records. 53.24 Section 53... Miscellaneous Provisions § 53.24 Records. (a) In general—(1) Form of records. The records required by the regulations in this part shall be kept accurately, but no particular form is required for keeping the...

  7. 7 CFR 989.176 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Records. 989.176 Section 989.176 Agriculture... CALIFORNIA Administrative Rules and Regulations Reports and Records § 989.176 Records. Each handler shall maintain complete, accurate, and current records of all of his business affairs concerning which he...

  8. 27 CFR 22.161 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Records. 22.161 Section 22... TREASURY LIQUORS DISTRIBUTION AND USE OF TAX-FREE ALCOHOL Records of Transactions § 22.161 Records. (a) General. All persons qualified under this part shall keep accurate records of all receipts,...

  9. 14 CFR 141.101 - Training records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Training records. 141.101 Section 141.101... OTHER CERTIFICATED AGENCIES PILOT SCHOOLS Records § 141.101 Training records. (a) Each holder of a pilot... accurate record of the participation of each student enrolled in an approved course of training...

  10. Foldable beam

    NASA Technical Reports Server (NTRS)

    Hedgepeth, J. M.; Coyner, J. V.; Crawford, R. F.

    1981-01-01

    A foldable beam possessing superior qualities of light weight, compactness for transportation, quick deployment with minimum use of force, and high strength is described. These qualities are achieved through the use of a series of longitudinally rigid segments, hinged along one side and threaded by one or two cables along the opposite side. Tightening the cables holds the beam extended. Loosening the cables permits the segments to fold away from the threaded side. In one embodiment the segments are connected by canted hinges with the result that the beam may be folded in a helix-like configuration around a cylinder. In another embodiment the segments themselves may be hinged to fold flat laterally as the beam is folded, resulting in a configuration that may be helixed around a shorter cylinder.

  11. Beam-beam deflection and signature curves for elliptic beams

    SciTech Connect

    Ziemann, V.

    1990-10-22

    In this note we will present closed expressions for the beam-beam deflection angle for arbitrary elliptic beams including tilt. From these expressions signature curves, i.e., systematic deviations from the round beam deflection curve due to ellipticity or tilt are derived. In the course of the presentation we will prove that it is generally impossible to infer individual beam sizes from beam-beam deflection scans. 3 refs., 2 figs.

  12. Beam position monitor system of J-PARC RCS

    NASA Astrophysics Data System (ADS)

    Hayashi, N.; Kawase, M.; Hatakeyama, S.; Hiroki, S.; Saeki, R.; Takahashi, H.; Teruyama, Y.; Toyokawa, R.; Arakawa, D.; Hiramatsu, S.; Lee, S.; Satou, K.; Tejima, M.; Toyama, T.

    2012-06-01

    The J-PARC RCS is a 25 Hz Rapid-Cycling proton Synchrotron and its designed beam power is 1 MW. The beam position monitor (BPM) system at J-PARC RCS is described in this paper. The pre-defined diameter of the BPM detectors is larger than 250 mm, however, the system has to measure the beam position very accurately. In addition, it is necessary to have a large dynamic range. The system should work not only for the high intensity but also for low intensity, such as during beam commissioning, when the intensity is below 1% of the design intensity. There are 54 BPM detectors around the ring and most of them are placed inside steering magnets because of quite limited space. The BPM detector is an electro-static type and it has four electrodes, and a pair of electrodes gives a good linear response with a diagonal cut shape to detect the charge center precisely. The signal processing units, which are equipped with 14-bit 40 MS/s ADC and 600 MHz DSP, have been developed. They are accessed via shared memory space and controlled by EPICS. Such a processing unit is capable of recording the full 25 Hz pulse data for the so-called "COD mode" (averaged beam position calculation) and it can also store the whole waveform data for further analysis, like turn-by-turn position calculation. The resolution was estimated to be 20 μm for "COD mode" and to be 0.3 mm for the turn-by-turn mode with relatively low intensity of 8×1011 ppp. The position accuracy is estimated to be about 0.5 mm using a newly developed Beam Based Alignment (BBA) method.

  13. A Self-Instructional Device for Conditioning Accurate Prosody.

    ERIC Educational Resources Information Center

    Buiten, Roger; Lane, Harlan

    1965-01-01

    A self-instructional device for conditioning accurate prosody in second-language learning is described in this article. The Speech Auto-Instructional Device (SAID) is electro-mechanical and performs three functions: SAID (1) presents to the student tape-recorded pattern sentences that are considered standards in prosodic performance; (2) processes…

  14. Quantifying Accurate Calorie Estimation Using the "Think Aloud" Method

    ERIC Educational Resources Information Center

    Holmstrup, Michael E.; Stearns-Bruening, Kay; Rozelle, Jeffrey

    2013-01-01

    Objective: Clients often have limited time in a nutrition education setting. An improved understanding of the strategies used to accurately estimate calories may help to identify areas of focused instruction to improve nutrition knowledge. Methods: A "Think Aloud" exercise was recorded during the estimation of calories in a standard dinner meal…

  15. Accurate Cross Sections for Microanalysis

    PubMed Central

    Rez, Peter

    2002-01-01

    To calculate the intensity of x-ray emission in electron beam microanalysis requires a knowledge of the energy distribution of the electrons in the solid, the energy variation of the ionization cross section of the relevant subshell, the fraction of ionizations events producing x rays of interest and the absorption coefficient of the x rays on the path to the detector. The theoretical predictions and experimental data available for ionization cross sections are limited mainly to K shells of a few elements. Results of systematic plane wave Born approximation calculations with exchange for K, L, and M shell ionization cross sections over the range of electron energies used in microanalysis are presented. Comparisons are made with experimental measurement for selected K shells and it is shown that the plane wave theory is not appropriate for overvoltages less than 2.5 V. PMID:27446747

  16. Double-shearing interferometer for accurate test of laser wavefront

    NASA Astrophysics Data System (ADS)

    Luan, Zhu; Liu, Liren; Zu, Jifeng; Teng, Shuyun

    2004-01-01

    Inter-satellite laser communications require nearly diffraction-limited laser beam, correspondingly an accurate test of laser wavefront is necessary. In this paper, an aperture-divided double lateral-shearing interferometer is developed which can be used for wavefront analysis ranged nearly from 0.1λ to λ with a simple structure and no alignment needed. The interferometer includes two Jamin plane parallel plates and four slightly wedge-shaped plates of the same size. The four wedged plates are combined into two pairs of different wedges, which are separately placed in the arms of the Jamin interferometer. The thickness of a plate leads to a beam shift, and the wedge a beam inclination, so that there appears two shearing interferogram of different background fringes in a divided aperture. Plane wavefront, perfect spherical wavefront and some types of aberration including primary spherical aberration, primary coma are simulated. It is concluded that the measurable wavefront height of laser beam reaches to better than 0.1λ. Note that the interference is from the beams of equal optical distance thus suitable for semiconductor lasers for the space application, which may be with the coherent length of millimeters.

  17. Accurate thermoplasmonic simulation of metallic nanoparticles

    NASA Astrophysics Data System (ADS)

    Yu, Da-Miao; Liu, Yan-Nan; Tian, Fa-Lin; Pan, Xiao-Min; Sheng, Xin-Qing

    2017-01-01

    Thermoplasmonics leads to enhanced heat generation due to the localized surface plasmon resonances. The measurement of heat generation is fundamentally a complicated task, which necessitates the development of theoretical simulation techniques. In this paper, an efficient and accurate numerical scheme is proposed for applications with complex metallic nanostructures. Light absorption and temperature increase are, respectively, obtained by solving the volume integral equation (VIE) and the steady-state heat diffusion equation through the method of moments (MoM). Previously, methods based on surface integral equations (SIEs) were utilized to obtain light absorption. However, computing light absorption from the equivalent current is as expensive as O(NsNv), where Ns and Nv, respectively, denote the number of surface and volumetric unknowns. Our approach reduces the cost to O(Nv) by using VIE. The accuracy, efficiency and capability of the proposed scheme are validated by multiple simulations. The simulations show that our proposed method is more efficient than the approach based on SIEs under comparable accuracy, especially for the case where many incidents are of interest. The simulations also indicate that the temperature profile can be tuned by several factors, such as the geometry configuration of array, beam direction, and light wavelength.

  18. Accurate Fission Data for Nuclear Safety

    NASA Astrophysics Data System (ADS)

    Solders, A.; Gorelov, D.; Jokinen, A.; Kolhinen, V. S.; Lantz, M.; Mattera, A.; Penttilä, H.; Pomp, S.; Rakopoulos, V.; Rinta-Antila, S.

    2014-05-01

    The Accurate fission data for nuclear safety (AlFONS) project aims at high precision measurements of fission yields, using the renewed IGISOL mass separator facility in combination with a new high current light ion cyclotron at the University of Jyväskylä. The 30 MeV proton beam will be used to create fast and thermal neutron spectra for the study of neutron induced fission yields. Thanks to a series of mass separating elements, culminating with the JYFLTRAP Penning trap, it is possible to achieve a mass resolving power in the order of a few hundred thousands. In this paper we present the experimental setup and the design of a neutron converter target for IGISOL. The goal is to have a flexible design. For studies of exotic nuclei far from stability a high neutron flux (1012 neutrons/s) at energies 1 - 30 MeV is desired while for reactor applications neutron spectra that resembles those of thermal and fast nuclear reactors are preferred. It is also desirable to be able to produce (semi-)monoenergetic neutrons for benchmarking and to study the energy dependence of fission yields. The scientific program is extensive and is planed to start in 2013 with a measurement of isomeric yield ratios of proton induced fission in uranium. This will be followed by studies of independent yields of thermal and fast neutron induced fission of various actinides.

  19. Composite box beam analysis - Theory and experiments

    NASA Technical Reports Server (NTRS)

    Bauchau, O. A.; Coffenberry, B. S.; Rehfield, L. W.

    1987-01-01

    Beam theory is widely used as a first approximation in numerous structural applications. When applied to composite beams, the accuracy of beam theory becomes questionable because (1) the shearing and warping deformations become significant, as the shearing stiffness of composite laminates is often very low, and (2) several elastic couplings can occur that strongly influence the behavior of composite beams. The torsional behavior of thin-walled composite beams has important implications for aeronautical structures and is deeply modified by the above nonclassical effects. This paper presents two comprehensive analysis methodologies for composite beams and describes experimental results obtained from a thin-walled, rectangular cross-sectional beam. The theoretical predictions are found in good agreement with the observed twist and strain distributions. Out-of-plane torsional warping of the cross-section is found to be the key factor for an accurate modeling of the torsional behavior of such structures.

  20. Virtual mask digital electron beam lithography

    DOEpatents

    Baylor, Larry R.; Thomas, Clarence E.; Voelkl, Edgar; Moore, James A.; Simpson, Michael L.; Paulus, Michael J.

    1999-01-01

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.

  1. Virtual mask digital electron beam lithography

    DOEpatents

    Baylor, L.R.; Thomas, C.E.; Voelkl, E.; Moore, J.A.; Simpson, M.L.; Paulus, M.J.

    1999-04-06

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made. 5 figs.

  2. Coherent beam-beam interaction with four colliding beams

    NASA Astrophysics Data System (ADS)

    Podobedov, B.; Siemann, R. H.

    1995-09-01

    The coherent beam-beam interaction in the absence of Landau damping is studied with a computer simulation of four space-charge-compensated colliding beams. Results are presented for the modes, phase space structures, widths, and growth rates of coherent beam-beam resonances. These results are compared with solutions of the Vlasov equation, and with measurements made at the Dispositif de Collisions dans l'Igloo (DCI) storage ring in Orsay, France, which operated with space-charge-compensated colliding beams.

  3. High Density Mastering Using Electron Beam

    NASA Astrophysics Data System (ADS)

    Kojima, Yoshiaki; Kitahara, Hiroaki; Kasono, Osamu; Katsumura, Masahiro; Wada, Yasumitsu

    1998-04-01

    A mastering system for the next-generation digital versatile disk (DVD) is required to have a higher resolution compared with the conventional mastering systems. We have developed an electron beam mastering machine which features a thermal field emitter and a vacuum sealed air spindle motor. Beam displacement caused by magnetic fluctuation with spindle rotation was about 60 nm(p-p) in both the radial and tangential directions. Considering the servo gain of a read-out system, it has little influence on the read-out signal in terms of tracking errors and jitters. The disk performance was evaluated by recording either the 8/16 modulation signal or a groove on the disk. The electron beam recording showed better jitter values from the disk playback than those from a laser beam recorder. The deviation of track pitch was 44 nm(p-p). We also confirmed the high density recording with a capacity reaching 30 GB.

  4. BEAM-BEAM SIMULATIONS FOR DOUBLE-GAUSSIAN BEAMS.

    SciTech Connect

    MONTAG, C.; MALITSKY, N.; BEN-ZVI, I.; LITVINENKO, V.

    2005-05-16

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-gaussian beams. Here we report the effect of low-frequency random tune modulations on diffusion in double-gaussian beams and compare the effects to those in beam-beam interactions with regular gaussian beams and identical tune shift parameters.

  5. Accurate ab Initio Spin Densities.

    PubMed

    Boguslawski, Katharina; Marti, Konrad H; Legeza, Ors; Reiher, Markus

    2012-06-12

    We present an approach for the calculation of spin density distributions for molecules that require very large active spaces for a qualitatively correct description of their electronic structure. Our approach is based on the density-matrix renormalization group (DMRG) algorithm to calculate the spin density matrix elements as a basic quantity for the spatially resolved spin density distribution. The spin density matrix elements are directly determined from the second-quantized elementary operators optimized by the DMRG algorithm. As an analytic convergence criterion for the spin density distribution, we employ our recently developed sampling-reconstruction scheme [J. Chem. Phys.2011, 134, 224101] to build an accurate complete-active-space configuration-interaction (CASCI) wave function from the optimized matrix product states. The spin density matrix elements can then also be determined as an expectation value employing the reconstructed wave function expansion. Furthermore, the explicit reconstruction of a CASCI-type wave function provides insight into chemically interesting features of the molecule under study such as the distribution of α and β electrons in terms of Slater determinants, CI coefficients, and natural orbitals. The methodology is applied to an iron nitrosyl complex which we have identified as a challenging system for standard approaches [J. Chem. Theory Comput.2011, 7, 2740].

  6. A Refined Zigzag Beam Theory for Composite and Sandwich Beams

    NASA Technical Reports Server (NTRS)

    Tessler, Alexander; Sciuva, Marco Di; Gherlone, Marco

    2009-01-01

    A new refined theory for laminated composite and sandwich beams that contains the kinematics of the Timoshenko Beam Theory as a proper baseline subset is presented. This variationally consistent theory is derived from the virtual work principle and employs a novel piecewise linear zigzag function that provides a more realistic representation of the deformation states of transverse-shear flexible beams than other similar theories. This new zigzag function is unique in that it vanishes at the top and bottom bounding surfaces of a beam. The formulation does not enforce continuity of the transverse shear stress across the beam s cross-section, yet is robust. Two major shortcomings that are inherent in the previous zigzag theories, shear-force inconsistency and difficulties in simulating clamped boundary conditions, and that have greatly limited the utility of these previous theories are discussed in detail. An approach that has successfully resolved these shortcomings is presented herein. Exact solutions for simply supported and cantilevered beams subjected to static loads are derived and the improved modelling capability of the new zigzag beam theory is demonstrated. In particular, extensive results for thick beams with highly heterogeneous material lay-ups are discussed and compared with corresponding results obtained from elasticity solutions, two other zigzag theories, and high-fidelity finite element analyses. Comparisons with the baseline Timoshenko Beam Theory are also presented. The comparisons clearly show the improved accuracy of the new, refined zigzag theory presented herein over similar existing theories. This new theory can be readily extended to plate and shell structures, and should be useful for obtaining relatively low-cost, accurate estimates of structural response needed to design an important class of high-performance aerospace structures.

  7. Differential equation based method for accurate approximations in optimization

    NASA Technical Reports Server (NTRS)

    Pritchard, Jocelyn I.; Adelman, Howard M.

    1990-01-01

    This paper describes a method to efficiently and accurately approximate the effect of design changes on structural response. The key to this new method is to interpret sensitivity equations as differential equations that may be solved explicitly for closed form approximations, hence, the method is denoted the Differential Equation Based (DEB) method. Approximations were developed for vibration frequencies, mode shapes and static displacements. The DEB approximation method was applied to a cantilever beam and results compared with the commonly-used linear Taylor series approximations and exact solutions. The test calculations involved perturbing the height, width, cross-sectional area, tip mass, and bending inertia of the beam. The DEB method proved to be very accurate, and in msot cases, was more accurate than the linear Taylor series approximation. The method is applicable to simultaneous perturbation of several design variables. Also, the approximations may be used to calculate other system response quantities. For example, the approximations for displacement are used to approximate bending stresses.

  8. Absolute calibration and beam background of the Squid Polarimeter

    SciTech Connect

    Blaskiewicz, M.M.; Cameron, P.R.; Shea, T.J.

    1996-12-31

    The problem of beam background in Squid Polarimetry is not without residual benefits. The authors may deliberately generate beam background by gently kicking the beam at the spin tune frequency. This signal may be used to accomplish a simple and accurate absolute calibration of the polarimeter. The authors present details of beam background calculations and their application to polarimeter calibration, and suggest a simple proof-of-principle accelerator experiment.

  9. Sea Beam Operator Manual.

    DTIC Science & Technology

    1983-05-12

    there is any skipping increase pen advantages for certain applications. The ballpoint , with pressure. Retrace line by reversing direction. a very fine...have returned The ballpoint pen uses replaceable elements available in to the initial starting point having drawn a red, blue, green and black. The fibre...Check 5.5 Depth - Horizontal Distance Printout 5.6 Beam (Mode 1) Display in Modes 2 and 3 5.7 Changing Pens 5.8 Changing Paper 5.9 UGR Monitor Recorder

  10. Keeping electronic records secure.

    PubMed

    Easton, David

    2013-10-01

    Are electronic engineering maintenance records relating to the hospital estate or a medical device as important as electronic patient records? Computer maintenance management systems (CMMS) are increasingly being used to manage all-round maintenance activities. However, the accuracy of the data held on them, and a level of security that prevents tampering with records, or other unauthorised changes to them to 'cover' poor practice, are both essential, so that, should an individual be injured or killed on hospital grounds, and a law suit follow, the estates team can be confident that it has accurate data to prove it has fulfilled its duty of care. Here David Easton MSc CEng FIHEEM MIET, director of Zener Engineering Services, and chair of IHEEM's Medical Devices Advisory Group, discusses the issues around maintenance databases, and the security and integrity of maintenance data.

  11. Coherent beam-beam effects, theory & observations

    SciTech Connect

    Yuri I Alexahin

    2003-07-16

    Current theoretical understanding of the coherent beam-beam effect as well as its experimental observations are discussed: conditions under which the coherent beambeam modes may appear, possibility of their resonant interaction (coherent resonances), stability of beam-beam oscillations in the presence of external impedances. A special attention is given to the coherent beam-beam modes of finite length bunches: the synchro-betatron coupling is shown to provide reduction in the coherent tuneshift and--at the synchrotron tune values smaller than the beam-beam parameter--Landau damping by overlapping synchrotron satellites.

  12. 12 CFR 609.945 - Records retention.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Records retention. 609.945 Section 609.945 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ELECTRONIC COMMERCE Standards for Boards and Management § 609.945 Records retention. Records stored electronically must be accurate,...

  13. 7 CFR 982.471 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false Records. 982.471 Section 982.471 Agriculture... WASHINGTON Administrative Rules and Regulations § 982.471 Records. Each handler shall maintain complete and accurate records showing the receipt, shipment and sale of all hazelnuts handled, used or...

  14. 7 CFR 982.471 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Records. 982.471 Section 982.471 Agriculture... WASHINGTON Administrative Rules and Regulations § 982.471 Records. Each handler shall maintain complete and accurate records showing the receipt, shipment and sale of all hazelnuts handled, used or...

  15. 42 CFR 60.56 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Records. 60.56 Section 60.56 Public Health PUBLIC... The School § 60.56 Records. (a) In addition to complying with the requirements of section 739(b) of the Act, each school must maintain an accurate, complete, and easily retrievable record with...

  16. 42 CFR 60.56 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Records. 60.56 Section 60.56 Public Health PUBLIC... The School § 60.56 Records. (a) In addition to complying with the requirements of section 739(b) of the Act, each school must maintain an accurate, complete, and easily retrievable record with...

  17. 7 CFR 982.471 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Records. 982.471 Section 982.471 Agriculture... WASHINGTON Administrative Rules and Regulations § 982.471 Records. Each handler shall maintain complete and accurate records showing the receipt, shipment and sale of all hazelnuts handled, used or...

  18. 7 CFR 20.9 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 1 2014-01-01 2014-01-01 false Records. 20.9 Section 20.9 Agriculture Office of the Secretary of Agriculture EXPORT SALES REPORTING REQUIREMENTS § 20.9 Records. Each reporting exporter shall establish and maintain accurate records as to all export sales of commodities subject to these...

  19. 12 CFR 609.945 - Records retention.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 7 2013-01-01 2013-01-01 false Records retention. 609.945 Section 609.945 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ELECTRONIC COMMERCE Standards for Boards and Management § 609.945 Records retention. Records stored electronically must be accurate,...

  20. 12 CFR 609.945 - Records retention.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 7 2012-01-01 2012-01-01 false Records retention. 609.945 Section 609.945 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ELECTRONIC COMMERCE Standards for Boards and Management § 609.945 Records retention. Records stored electronically must be accurate,...

  1. 12 CFR 609.945 - Records retention.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 6 2011-01-01 2011-01-01 false Records retention. 609.945 Section 609.945 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ELECTRONIC COMMERCE Standards for Boards and Management § 609.945 Records retention. Records stored electronically must be accurate,...

  2. 12 CFR 609.945 - Records retention.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 7 2014-01-01 2014-01-01 false Records retention. 609.945 Section 609.945 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ELECTRONIC COMMERCE Standards for Boards and Management § 609.945 Records retention. Records stored electronically must be accurate,...

  3. 30 CFR 250.1619 - Well records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Well records. 250.1619 Section 250.1619 Mineral... OPERATIONS IN THE OUTER CONTINENTAL SHELF Sulphur Operations § 250.1619 Well records. (a) Complete and accurate records for each well and all well operations shall be retained for a period of 2 years at...

  4. 30 CFR 250.1619 - Well records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Well records. 250.1619 Section 250.1619 Mineral... Well records. (a) Complete and accurate records for each well and all well operations shall be retained... if cored and analyzed; the kind, weight, size, grade, and setting depth of casing; all well logs...

  5. Logbook Language Characteristics and Recordation Requirement

    ERIC Educational Resources Information Center

    Huang, Gang; Shen, Jiang

    2011-01-01

    With a view of the deficiency irregular phenomena existing in logbook recordation among Chinese crew members, this paper analyzed the language characteristics and recording requirement of logbook, expounded how to employ accurate, concise and precise words to record logbook, listed out matters to be paid attention to in the process of recording…

  6. High speed holographic digital recorder.

    PubMed

    Roberts, H N; Watkins, J W; Johnson, R H

    1974-04-01

    Concepts, feasibility experiments, and key component developments are described for a holographic digital record/reproduce system with the potential for 1.0 Gbit/sec rates and higher. Record rates of 500 Mbits/sec have been demonstrated with a ten-channel acoustooptic modulator array and a mode-locked, cavity-dumped argon-ion laser. Acoustooptic device technology has been advanced notably during the development of mode lockers, cavity dumpers, beam deflectors, and multichannel modulator arrays. The development of high speed multichannel photodetector arrays for the readout subsystem requires special attention. The feasibility of 1.0 Gbits/sec record rates has been demonstrated.

  7. Accurate measurement of the helical twisting power of chiral dopants

    NASA Astrophysics Data System (ADS)

    Kosa, Tamas; Bodnar, Volodymyr; Taheri, Bahman; Palffy-Muhoray, Peter

    2002-03-01

    We propose a method for the accurate determination of the helical twisting power (HTP) of chiral dopants. In the usual Cano-wedge method, the wedge angle is determined from the far-field separation of laser beams reflected from the windows of the test cell. Here we propose to use an optical fiber based spectrometer to accurately measure the cell thickness. Knowing the cell thickness at the positions of the disclination lines allows determination of the HTP. We show that this extension of the Cano-wedge method greatly increases the accuracy with which the HTP is determined. We show the usefulness of this method by determining the HTP of ZLI811 in a variety of hosts with negative dielectric anisotropy.

  8. Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system.

    PubMed

    Alaei, Parham; Spezi, Emiliano

    2012-11-08

    The feasibility of accounting of the dose from kilovoltage cone-beam CT in treatment planning has been discussed previously for a single cone-beam CT (CBCT) beam from one manufacturer. Modeling the beams and computing the dose from the full set of beams produced by a kilovoltage cone-beam CT system requires extensive beam data collection and verification, and is the purpose of this work. The beams generated by Elekta X-ray volume imaging (XVI) kilovoltage CBCT (kV CBCT) system for various cassettes and filters have been modeled in the Philips Pinnacle treatment planning system (TPS) and used to compute dose to stack and anthropomorphic phantoms. The results were then compared to measurements made using thermoluminescent dosimeters (TLDs) and Monte Carlo (MC) simulations. The agreement between modeled and measured depth-dose and cross profiles is within 2% at depths beyond 1 cm for depth-dose curves, and for regions within the beam (excluding penumbra) for cross profiles. The agreements between TPS-calculated doses, TLD measurements, and Monte Carlo simulations are generally within 5% in the stack phantom and 10% in the anthropomorphic phantom, with larger variations observed for some of the measurement/calculation points. Dose computation using modeled beams is reasonably accurate, except for regions that include bony anatomy. Inclusion of this dose in treatment plans can lead to more accurate dose prediction, especially when the doses to organs at risk are of importance.

  9. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  10. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  11. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  12. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  13. 38 CFR 4.46 - Accurate measurement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect...

  14. High resolution beam profile monitors in the SLC

    SciTech Connect

    Ross, M.C.; Seeman, J.T.; Jobe, R.K.; Sheppard, J.C.; Stiening, R.F.

    1985-04-01

    In the SLC linac, low emittance beams with typical transverse dimensions less than 0.2 mm must be accelerated without effective emittance growth. In order to monitor this we have installed a high resolution beam profile monitor system which consists of an aluminum target covered with a fine-grained phosphor, a magnifying optical system, a television camera and video signal recording electronics. The image formed when the beam strikes the phosphor screen is viewed on a CRT monitor at the console and selected horizontal and vertical slices of the beam spot intensity are recorded. A 20 MHz transient waveform recorder is used to sample and digitize the raw video signal along the selected slice. The beam width is determined by fitting the background subtracted data to a Gaussian. Beam spots less than 6 x 3 mm can be viewed. Beam spot sizes sigma/sub x,y/ < 80 ..mu..m have been measured. 9 refs., 4 figs.

  15. Generation of low-divergence laser beams

    DOEpatents

    Kronberg, James W.

    1993-01-01

    Apparatus for transforming a conventional beam of coherent light, having a Gaussian energy distribution and relatively high divergence, into a beam in which the energy distribution approximates a single, non-zero-order Bessel function and which therefore has much lower divergence. The apparatus comprises a zone plate having transmitting and reflecting zones defined by the pattern of light interference produced by the combination of a beam of coherent light with a Gaussian energy distribution and one having such a Bessel distribution. The interference pattern between the two beams is a concentric array of multiple annuli, and is preferably recorded as a hologram. The hologram is then used to form the transmitting and reflecting zones by photo-etching portions of a reflecting layer deposited on a plate made of a transmitting material. A Bessel beam, containing approximately 50% of the energy of the incident beam, is produced by passing a Gaussian beam through such a Bessel zone plate. The reflected beam, also containing approximately 50% of the incident beam energy and having a Bessel energy distribution, can be redirected in the same direction and parallel to the transmitted beam. Alternatively, a filter similar to the Bessel zone plate can be placed within the resonator cavity of a conventional laser system having a front mirror and a rear mirror, preferably axially aligned with the mirrors and just inside the front mirror to generate Bessel energy distribution light beams at the laser source.

  16. Generation of low-divergence laser beams

    DOEpatents

    Kronberg, J.W.

    1993-09-14

    Apparatus for transforming a conventional beam of coherent light, having a Gaussian energy distribution and relatively high divergence, into a beam in which the energy distribution approximates a single, non-zero-order Bessel function and which therefore has much lower divergence. The apparatus comprises a zone plate having transmitting and reflecting zones defined by the pattern of light interference produced by the combination of a beam of coherent light with a Gaussian energy distribution and one having such a Bessel distribution. The interference pattern between the two beams is a concentric array of multiple annuli, and is preferably recorded as a hologram. The hologram is then used to form the transmitting and reflecting zones by photo-etching portions of a reflecting layer deposited on a plate made of a transmitting material. A Bessel beam, containing approximately 50% of the energy of the incident beam, is produced by passing a Gaussian beam through such a Bessel zone plate. The reflected beam, also containing approximately 50% of the incident beam energy and having a Bessel energy distribution, can be redirected in the same direction and parallel to the transmitted beam. Alternatively, a filter similar to the Bessel zone plate can be placed within the resonator cavity of a conventional laser system having a front mirror and a rear mirror, preferably axially aligned with the mirrors and just inside the front mirror to generate Bessel energy distribution light beams at the laser source. 11 figures.

  17. Further evidence of antibunching of two coherent beams of fermions

    SciTech Connect

    Iannuzzi, M.; Messi, R.; Moricciani, D.; Orecchini, A.; Sacchetti, F.; Facchi, P.; Pascazio, S.

    2011-07-15

    We describe an experiment confirming the evidence of the antibunching effect on a beam of noninteracting thermal neutrons. The comparison between the results recorded with a high-energy-resolution source of neutrons and those recorded with a broad-energy-resolution source enables us to clarify the role played by the beam coherence in the occurrence of the antibunching effect.

  18. Beam Breakup Effects in Dielectric Based Accelerators

    SciTech Connect

    Schoessow, P.; Kanareykin, A.; Jing, C.; Kustov, A.; Altmark, A.; Power, J. G.; Gai, W.

    2009-01-22

    The dynamics of the beam in structure-based wakefield accelerators leads to beam stability issues not ordinarily found in other machines. In particular, the high current drive beam in an efficient wakefield accelerator loses a large fraction of its energy in the decelerator structure, resulting in physical emittance growth, increased energy spread, and the possibility of head-tail instability for an off axis beam, all of which can lead to severe reduction of beam intensity. Beam breakup (BBU) effects resulting from parasitic wakefields provide a potentially serious limitation to the performance of dielectric structure based wakefield accelerators as well. We report on experimental and numerical investigation of BBU and its mitigation. The experimental program focuses on BBU measurements at the AWA facility in a number of high gradient and high transformer ratio wakefield devices. New pickup-based beam diagnostics will provide methods for studying parasitic wakefields that are currently unavailable. The numerical part of this research is based on a particle-Green's function beam breakup code we are developing that allows rapid, efficient simulation of beam breakup effects in advanced linear accelerators. The goal of this work is to be able to compare the results of detailed experimental measurements with the accurate numerical results and to design an external FODO channel for the control of the beam in the presence of strong transverse wakefields.

  19. Helium-neon laser: thermal high-resolution recording.

    PubMed

    Carlson, C O; Stone, E; Bernstein, H L; Tomita, W K; Myers, W C

    1966-12-23

    Scan-line recording by means of a moving laser spot has been achieved on metallic and organic thin films Recording rates of the order of one million spots per second were obtained with a laser beam power of 38 milliwatts at the recording surface. Typical recorded line widths were of the order of 2 microns.

  20. Beam geometry selection using sequential beam addition

    SciTech Connect

    Popple, Richard A. Brezovich, Ivan A.; Fiveash, John B.

    2014-05-15

    Purpose: The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. Methods: The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. Results: In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. Conclusions: For situations in which beam geometry has a significant effect on the objective function, SBA can identify

  1. Accurate paleointensities - the multi-method approach

    NASA Astrophysics Data System (ADS)

    de Groot, Lennart

    2016-04-01

    The accuracy of models describing rapid changes in the geomagnetic field over the past millennia critically depends on the availability of reliable paleointensity estimates. Over the past decade methods to derive paleointensities from lavas (the only recorder of the geomagnetic field that is available all over the globe and through geologic times) have seen significant improvements and various alternative techniques were proposed. The 'classical' Thellier-style approach was optimized and selection criteria were defined in the 'Standard Paleointensity Definitions' (Paterson et al, 2014). The Multispecimen approach was validated and the importance of additional tests and criteria to assess Multispecimen results must be emphasized. Recently, a non-heating, relative paleointensity technique was proposed -the pseudo-Thellier protocol- which shows great potential in both accuracy and efficiency, but currently lacks a solid theoretical underpinning. Here I present work using all three of the aforementioned paleointensity methods on suites of young lavas taken from the volcanic islands of Hawaii, La Palma, Gran Canaria, Tenerife, and Terceira. Many of the sampled cooling units are <100 years old, the actual field strength at the time of cooling is therefore reasonably well known. Rather intuitively, flows that produce coherent results from two or more different paleointensity methods yield the most accurate estimates of the paleofield. Furthermore, the results for some flows pass the selection criteria for one method, but fail in other techniques. Scrutinizing and combing all acceptable results yielded reliable paleointensity estimates for 60-70% of all sampled cooling units - an exceptionally high success rate. This 'multi-method paleointensity approach' therefore has high potential to provide the much-needed paleointensities to improve geomagnetic field models for the Holocene.

  2. Accurate Biomass Estimation via Bayesian Adaptive Sampling

    NASA Astrophysics Data System (ADS)

    Wheeler, K.; Knuth, K.; Castle, P.

    2005-12-01

    Typical estimates of standing wood derived from remote sensing sources take advantage of aggregate measurements of canopy heights (e.g. LIDAR) and canopy diameters (segmentation of IKONOS imagery) to obtain a wood volume estimate by assuming homogeneous species and a fixed function that returns volume. The validation of such techniques use manually measured diameter at breast height records (DBH). Our goal is to improve the accuracy and applicability of biomass estimation methods to heterogeneous forests and transitional areas. We are developing estimates with quantifiable uncertainty using a new form of estimation function, active sampling, and volumetric reconstruction image rendering for species specific mass truth. Initially we are developing a Bayesian adaptive sampling method for BRDF associated with the MISR Rahman model with respect to categorical biomes. This involves characterizing the probability distributions of the 3 free parameters of the Rahman model for the 6 categories of biomes used by MISR. Subsequently, these distributions can be used to determine the optimal sampling methodology to distinguish biomes during acquisition. We have a remotely controlled semi-autonomous helicopter that has stereo imaging, lidar, differential GPS, and spectrometers covering wavelengths from visible to NIR. We intend to automatically vary the way points of the flight path via the Bayesian adaptive sampling method. The second critical part of this work is in automating the validation of biomass estimates via using machine vision techniques. This involves taking 2-D pictures of trees of known species, and then via Bayesian techniques, reconstructing 3-D models of the trees to estimate the distribution moments associated with wood volume. Similar techniques have been developed by the medical imaging community. This then provides probability distributions conditional upon species. The final part of this work is in relating the BRDF actively sampled measurements to species

  3. An infrastructure for accurate characterization of single-event transients in digital circuits☆

    PubMed Central

    Savulimedu Veeravalli, Varadan; Polzer, Thomas; Schmid, Ulrich; Steininger, Andreas; Hofbauer, Michael; Schweiger, Kurt; Dietrich, Horst; Schneider-Hornstein, Kerstin; Zimmermann, Horst; Voss, Kay-Obbe; Merk, Bruno; Hajek, Michael

    2013-01-01

    We present the architecture and a detailed pre-fabrication analysis of a digital measurement ASIC facilitating long-term irradiation experiments of basic asynchronous circuits, which also demonstrates the suitability of the general approach for obtaining accurate radiation failure models developed in our FATAL project. Our ASIC design combines radiation targets like Muller C-elements and elastic pipelines as well as standard combinational gates and flip-flops with an elaborate on-chip measurement infrastructure. Major architectural challenges result from the fact that the latter must operate reliably under the same radiation conditions the target circuits are exposed to, without wasting precious die area for a rad-hard design. A measurement architecture based on multiple non-rad-hard counters is used, which we show to be resilient against double faults, as well as many triple and even higher-multiplicity faults. The design evaluation is done by means of comprehensive fault injection experiments, which are based on detailed Spice models of the target circuits in conjunction with a standard double-exponential current injection model for single-event transients (SET). To be as accurate as possible, the parameters of this current model have been aligned with results obtained from 3D device simulation models, which have in turn been validated and calibrated using micro-beam radiation experiments at the GSI in Darmstadt, Germany. For the latter, target circuits instrumented with high-speed sense amplifiers have been used for analog SET recording. Together with a probabilistic analysis of the sustainable particle flow rates, based on a detailed area analysis and experimental cross-section data, we can conclude that the proposed architecture will indeed sustain significant target hit rates, without exceeding the resilience bound of the measurement infrastructure. PMID:24748694

  4. An infrastructure for accurate characterization of single-event transients in digital circuits.

    PubMed

    Savulimedu Veeravalli, Varadan; Polzer, Thomas; Schmid, Ulrich; Steininger, Andreas; Hofbauer, Michael; Schweiger, Kurt; Dietrich, Horst; Schneider-Hornstein, Kerstin; Zimmermann, Horst; Voss, Kay-Obbe; Merk, Bruno; Hajek, Michael

    2013-11-01

    We present the architecture and a detailed pre-fabrication analysis of a digital measurement ASIC facilitating long-term irradiation experiments of basic asynchronous circuits, which also demonstrates the suitability of the general approach for obtaining accurate radiation failure models developed in our FATAL project. Our ASIC design combines radiation targets like Muller C-elements and elastic pipelines as well as standard combinational gates and flip-flops with an elaborate on-chip measurement infrastructure. Major architectural challenges result from the fact that the latter must operate reliably under the same radiation conditions the target circuits are exposed to, without wasting precious die area for a rad-hard design. A measurement architecture based on multiple non-rad-hard counters is used, which we show to be resilient against double faults, as well as many triple and even higher-multiplicity faults. The design evaluation is done by means of comprehensive fault injection experiments, which are based on detailed Spice models of the target circuits in conjunction with a standard double-exponential current injection model for single-event transients (SET). To be as accurate as possible, the parameters of this current model have been aligned with results obtained from 3D device simulation models, which have in turn been validated and calibrated using micro-beam radiation experiments at the GSI in Darmstadt, Germany. For the latter, target circuits instrumented with high-speed sense amplifiers have been used for analog SET recording. Together with a probabilistic analysis of the sustainable particle flow rates, based on a detailed area analysis and experimental cross-section data, we can conclude that the proposed architecture will indeed sustain significant target hit rates, without exceeding the resilience bound of the measurement infrastructure.

  5. Electron Microprobe Analysis Techniques for Accurate Measurements of Apatite

    NASA Astrophysics Data System (ADS)

    Goldoff, B. A.; Webster, J. D.; Harlov, D. E.

    2010-12-01

    Apatite [Ca5(PO4)3(F, Cl, OH)] is a ubiquitous accessory mineral in igneous, metamorphic, and sedimentary rocks. The mineral contains halogens and hydroxyl ions, which can provide important constraints on fugacities of volatile components in fluids and other phases in igneous and metamorphic environments in which apatite has equilibrated. Accurate measurements of these components in apatite are therefore necessary. Analyzing apatite by electron microprobe (EMPA), which is a commonly used geochemical analytical technique, has often been found to be problematic and previous studies have identified sources of error. For example, Stormer et al. (1993) demonstrated that the orientation of an apatite grain relative to the incident electron beam could significantly affect the concentration results. In this study, a variety of alternative EMPA operating conditions for apatite analysis were investigated: a range of electron beam settings, count times, crystal grain orientations, and calibration standards were tested. Twenty synthetic anhydrous apatite samples that span the fluorapatite-chlorapatite solid solution series, and whose halogen concentrations were determined by wet chemistry, were analyzed. Accurate measurements of these samples were obtained with many EMPA techniques. One effective method includes setting a static electron beam to 10-15nA, 15kV, and 10 microns in diameter. Additionally, the apatite sample is oriented with the crystal’s c-axis parallel to the slide surface and the count times are moderate. Importantly, the F and Cl EMPA concentrations are in extremely good agreement with the wet-chemical data. We also present EMPA operating conditions and techniques that are problematic and should be avoided. J.C. Stormer, Jr. et al., Am. Mineral. 78 (1993) 641-648.

  6. 21 CFR 111.605 - What requirements apply to the records that you make and keep?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN..., microfiche, or other accurate reproductions of the original records), or as electronic records. (c)...

  7. 7 CFR 989.77 - Verification of reports and rec-ords.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PRODUCED FROM GRAPES GROWN IN CALIFORNIA Order Regulating Handling Reports and Records § 989.77... facilitate inspection, and shall maintain storage records which will permit accurate identification...

  8. An etched fiber optic vibration sensor to monitor the simply supported beam

    NASA Astrophysics Data System (ADS)

    Putha, Kishore; Dinakar, Dantala; Rao, Pachava V.; Sengupta, Dipankar; Srimannarayana, K.; Sai Shankar, M.

    2012-04-01

    A single mode fiber optic vibration senor is designed and demonstrated to monitor the vibration of a simply supported beam. A rectangular beam (length 30.8 cm, width 2.5cm and thickness 0.5mm) made of spring-steel is arranged as simply supported beam and is made to vibrate periodically. To sense the vibrations a telecommunication fiber is chemically etched such that its diameter reaches 50μm and is glued using an epoxy at the centre of the beam. A broadband light (1550nm) is launched into Fiber Bragg Grating (FBG) through a circulator. The light reflected by the FBG (1540.32nm) is coupled into the centre etched fibre through the circulator and is detected by photodiode connected to a transimpedance amplifier. The electrical signal is logged into the computer through NI-6016 DAQ. The sensor works on transmission power loss due to the mode volume mismatch and flexural strain (field strength) of the fiber due to the bending in the fiber with respect to the bending of the spring-steel beam. The beam is made to vibrate and the corresponding intensity of light is recorded. Fast Fourier transform (FFT) technique is used to measure the frequencies of vibration. The results show that this sensor can sense vibration of low frequency accurately and repeatability is high. The sensor has high linear response to axial displacement of about 0.8 mm with sensitivity of 32mV/10μm strain. This lowcost sensor may find a place in industry to monitor the vibrations of the beam structures and bridges.

  9. Molecular-beam scattering

    SciTech Connect

    Vernon, M.F.

    1983-07-01

    The molecular-beam technique has been used in three different experimental arrangements to study a wide range of inter-atomic and molecular forces. Chapter 1 reports results of a low-energy (0.2 kcal/mole) elastic-scattering study of the He-Ar pair potential. The purpose of the study was to accurately characterize the shape of the potential in the well region, by scattering slow He atoms produced by expanding a mixture of He in N/sub 2/ from a cooled nozzle. Chapter 2 contains measurements of the vibrational predissociation spectra and product translational energy for clusters of water, benzene, and ammonia. The experiments show that most of the product energy remains in the internal molecular motions. Chapter 3 presents measurements of the reaction Na + HCl ..-->.. NaCl + H at collision energies of 5.38 and 19.4 kcal/mole. This is the first study to resolve both scattering angle and velocity for the reaction of a short lived (16 nsec) electronic excited state. Descriptions are given of computer programs written to analyze molecular-beam expansions to extract information characterizing their velocity distributions, and to calculate accurate laboratory elastic-scattering differential cross sections accounting for the finite apparatus resolution. Experimental results which attempted to determine the efficiency of optically pumping the Li(2/sup 2/P/sub 3/2/) and Na(3/sup 2/P/sub 3/2/) excited states are given. A simple three-level model for predicting the steady-state fraction of atoms in the excited state is included.

  10. Wide spectral band beam analysis

    NASA Astrophysics Data System (ADS)

    Aharon, Oren

    2015-03-01

    The reality in laser beam profiling is that measurements are performed over a wide spectrum of wavelengths and power ranges. Many applications use multiple laser wavelengths with very different power levels, a fact which dictates a need for a better measuring tool. Rapid progress in the fiber laser area has increased the demand for lasers in the wavelength range of 900 - 1030 nm, while the telecommunication market has increased the demand for wavelength range of 1300nm - 1600 nm, on the other hand the silicone chip manufacturing and mass production requirements tend to lower the laser wavelength towards the 190nm region. In many cases there is a need to combine several lasers together in order to perform a specific task. A typical application is to combine one visible laser for pointing, with a different laser for material processing with a very different wavelength and power level. The visible laser enables accurate pointing before the second laser is operated. The beam profile of the intensity distribution is an important parameter that indicates how a laser beam will behave in an application. Currently a lab, where many different lasers are used, will find itself using various laser beam profilers from several vendors with different specifications and accuracies. It is the propose of this article to present a technological breakthrough in the area of detectors, electronics and optics allowing intricate measurements of lasers with different wavelength and with power levels that vary many orders of magnitude by a single beam profiler.

  11. Student Records

    ERIC Educational Resources Information Center

    Fields, Cheryl

    2005-01-01

    Another topic involving privacy has attracted considerable attention in recent months--the "student unit record" issue. The U.S. Department of Education concluded in March that it would be feasible to help address lawmakers' concerns about accountability in higher education by constructing a database capable of tracking students from institution…

  12. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    SciTech Connect

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  13. 9 CFR 121.17 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... and characteristics (e.g., strain designation, GenBank Accession number, etc.); (ii) The quantity... records and databases created under this part are accurate, have controlled access, and that...

  14. Pulsed laser beam intensity monitor

    SciTech Connect

    Cason, C.M.; Jones, R.W.

    1982-07-13

    A pulsed laser beam intensity monitor measures the peak power within a selectable cross section of a test laser beam and measures integrated energy of the beam during the pulse period of a test laser. A continuous wave laser and a pulsed ruby laser are coaxially arranged for simultaneously transmitting optical output energy through a crystal flat during the time a test laser pulse is transmitted through the flat. Due to stress birefringence in the crystal, the ruby laser pulse transmitted through the flat is recorded and analyzed to provide peak power information about the test laser output pulse, and the continuous wave laser output reflected from the crystal flat provides a measurement of energy during the test laser pulse.

  15. In vivo dosimetry in external beam radiotherapy

    SciTech Connect

    Mijnheer, Ben; Beddar, Sam; Izewska, Joanna; Reft, Chester

    2013-07-15

    In vivo dosimetry (IVD) is in use in external beam radiotherapy (EBRT) to detect major errors, to assess clinically relevant differences between planned and delivered dose, to record dose received by individual patients, and to fulfill legal requirements. After discussing briefly the main characteristics of the most commonly applied IVD systems, the clinical experience of IVD during EBRT will be summarized. Advancement of the traditional aspects of in vivo dosimetry as well as the development of currently available and newly emerging noninterventional technologies are required for large-scale implementation of IVD in EBRT. These new technologies include the development of electronic portal imaging devices for 2D and 3D patient dosimetry during advanced treatment techniques, such as IMRT and VMAT, and the use of IVD in proton and ion radiotherapy by measuring the decay of radiation-induced radionuclides. In the final analysis, we will show in this Vision 20/20 paper that in addition to regulatory compliance and reimbursement issues, the rationale for in vivo measurements is to provide an accurate and independent verification of the overall treatment procedure. It will enable the identification of potential errors in dose calculation, data transfer, dose delivery, patient setup, and changes in patient anatomy. It is the authors' opinion that all treatments with curative intent should be verified through in vivo dose measurements in combination with pretreatment checks.

  16. Experience with a double-compensating beam calorimeter

    SciTech Connect

    Jarmie, N.; Brown, R.E.; Hardekopf, R.A.; Martinez, R.

    1982-01-01

    In an experiment to measure the D(t,..cap alpha..)n cross section at beam energies of 10 to 120 keV, we have developed a double-compensating beam calorimeter, based on a Swiss design to measure the partical beam intensity. A Faraday cup is not useful because of considerable charge exchange in the target gas at such low beam energies. We calibrated the calorimeter both with 10- and 3-MeV protons (comparing with a Faraday-cup measurement of the beam flux) and with the heat generated in a precision resistor. Both methods agree and give a calibration accurate to +- 0.08% over a range of 10 to 800 mW beam power. Beam powers as low as 5 mW may be used, but with less accuracy. The beam energy must be known in order to calculate the particle intensity. Some difficulties with and peculiarities of the device are discussed.

  17. Initial alignment method for free space optics laser beam

    NASA Astrophysics Data System (ADS)

    Shimada, Yuta; Tashiro, Yuki; Izumi, Kiyotaka; Yoshida, Koichi; Tsujimura, Takeshi

    2016-08-01

    The authors have newly proposed and constructed an active free space optics transmission system. It is equipped with a motor driven laser emitting mechanism and positioning photodiodes, and it transmits a collimated thin laser beam and accurately steers the laser beam direction. It is necessary to introduce the laser beam within sensible range of the receiver in advance of laser beam tracking control. This paper studies an estimation method of laser reaching point for initial laser beam alignment. Distributed photodiodes detect laser luminescence at respective position, and the optical axis of laser beam is analytically presumed based on the Gaussian beam optics. Computer simulation evaluates the accuracy of the proposed estimation methods, and results disclose that the methods help us to guide the laser beam to a distant receiver.

  18. Electron Beam Welding of Gear Wheels by Splitted Beam

    NASA Astrophysics Data System (ADS)

    Dřímal, Daniel

    2014-06-01

    This contribution deals with the issue of electron beam welding of high-accurate gear wheels composed of a spur gearing and fluted shaft joined with a face weld for automotive industry. Both parts made of the high-strength low-alloy steel are welded in the condition after final machining and heat treatment, performed by case hardening, whereas it is required that the run-out in the critical point of weldment after welding, i. e. after the final operation, would be 0.04 mm max.. In case of common welding procedure, cracks were formed in the weld, initiated by spiking in the weld root. Crack formation was prevented by the use of an interlocking joint with a rounded recess and suitable welding parameters, eliminating crack initiation by spiking in the weld root. Minimisation of the welding distortions was achieved by the application of tack welding with simultaneous splitting of one beam into two parts in the opposite sections of circumferential face weld attained on the principle of a new system of controlled deflection with digital scanning of the beam. This welding procedure assured that the weldment temperature after welding would not be higher than 400 °C. Thus, this procedure allowed achieving the final run-outs in the critical point of gearwheels within the maximum range up to 0.04 mm, which is acceptable for the given application. Accurate optical measurements did not reveal any changes in the teeth dimensions.

  19. Novel digital optical tape recorder

    NASA Astrophysics Data System (ADS)

    Oakley, William S.

    1996-01-01

    A novel very high performance digital optical tape recorder is described. Linear tape motion at 4.2 meters per second and simultaneous writing of about 80 parallel bit tracks with a data density of three bits per micron per track enables a data rate of 1,000 Megabits per second, sufficient for a data rate of 100 megabytes per second with error correction. One micron track to track spacing gives a data capacity of one Terabyte (1,000 GB) in a single '3480' style tape cartridge shell. A single beam from a frequency doubled, laser diode pumped, solid state (2X- LDP-SS) laser is split into a multiplicity of like beams, each of which is then independently modulated at 12.5 MHz for recording.

  20. Practical Teaching about Electron Beams

    ERIC Educational Resources Information Center

    Strawson, R. J.

    2009-01-01

    If you have seen tubes like the ones we describe here in the back of a cupboard but have been reluctant to use them, now is the time to get them out. The aim of this article is to record the history of teaching about electron beams, particularly with Teltron equipment, and in doing so encourage those schools that are equipped with these tubes to…

  1. Extracting Time-Accurate Acceleration Vectors From Nontrivial Accelerometer Arrangements.

    PubMed

    Franck, Jennifer A; Blume, Janet; Crisco, Joseph J; Franck, Christian

    2015-09-01

    Sports-related concussions are of significant concern in many impact sports, and their detection relies on accurate measurements of the head kinematics during impact. Among the most prevalent recording technologies are videography, and more recently, the use of single-axis accelerometers mounted in a helmet, such as the HIT system. Successful extraction of the linear and angular impact accelerations depends on an accurate analysis methodology governed by the equations of motion. Current algorithms are able to estimate the magnitude of acceleration and hit location, but make assumptions about the hit orientation and are often limited in the position and/or orientation of the accelerometers. The newly formulated algorithm presented in this manuscript accurately extracts the full linear and rotational acceleration vectors from a broad arrangement of six single-axis accelerometers directly from the governing set of kinematic equations. The new formulation linearizes the nonlinear centripetal acceleration term with a finite-difference approximation and provides a fast and accurate solution for all six components of acceleration over long time periods (>250 ms). The approximation of the nonlinear centripetal acceleration term provides an accurate computation of the rotational velocity as a function of time and allows for reconstruction of a multiple-impact signal. Furthermore, the algorithm determines the impact location and orientation and can distinguish between glancing, high rotational velocity impacts, or direct impacts through the center of mass. Results are shown for ten simulated impact locations on a headform geometry computed with three different accelerometer configurations in varying degrees of signal noise. Since the algorithm does not require simplifications of the actual impacted geometry, the impact vector, or a specific arrangement of accelerometer orientations, it can be easily applied to many impact investigations in which accurate kinematics need to

  2. Relativistic electron beam generator

    DOEpatents

    Mooney, L.J.; Hyatt, H.M.

    1975-11-11

    A relativistic electron beam generator for laser media excitation is described. The device employs a diode type relativistic electron beam source having a cathode shape which provides a rectangular output beam with uniform current density.

  3. Laser beam monitoring system

    DOEpatents

    Weil, Bradley S.; Wetherington, Jr., Grady R.

    1985-01-01

    Laser beam monitoring systems include laser-transparent plates set at an angle to the laser beam passing therethrough and light sensor for detecting light reflected from an object on which the laser beam impinges.

  4. Beam imaging sensor

    DOEpatents

    McAninch, Michael D.; Root, Jeffrey J.

    2016-07-05

    The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature.

  5. Tunable beam displacer

    SciTech Connect

    Salazar-Serrano, Luis José; Valencia, Alejandra; Torres, Juan P.

    2015-03-15

    We report the implementation of a tunable beam displacer, composed of a polarizing beam splitter (PBS) and two mirrors, that divides an initially polarized beam into two parallel beams whose separation can be continuously tuned. The two output beams are linearly polarized with either vertical or horizontal polarization and no optical path difference is introduced between them. The wavelength dependence of the device as well as the maximum separation between the beams achievable is limited mainly by the PBS characteristics.

  6. Thermal modeling of head disk interface system in heat assisted magnetic recording

    SciTech Connect

    Vemuri, Sesha Hari; Seung Chung, Pil; Jhon, Myung S.; Min Kim, Hyung

    2014-05-07

    A thorough understanding of the temperature profiles introduced by the heat assisted magnetic recording is required to maintain the hotspot at the desired location on the disk with minimal heat damage to other components. Here, we implement a transient mesoscale modeling methodology termed lattice Boltzmann method (LBM) for phonons (which are primary carriers of energy) in the thermal modeling of the head disk interface (HDI) components, namely, carbon overcoat (COC). The LBM can provide more accurate results compared to conventional Fourier methodology by capturing the nanoscale phenomena due to ballistic heat transfer. We examine the in-plane and out-of-plane heat transfer in the COC via analyzing the temperature profiles with a continuously focused and pulsed laser beam on a moving disk. Larger in-plane hotspot widening is observed in continuously focused laser beam compared to a pulsed laser. A pulsed laser surface develops steeper temperature gradients compared to continuous hotspot. Furthermore, out-of-plane heat transfer from the COC to the media is enhanced with a continuous laser beam then a pulsed laser, while the temperature takes around 140 fs to reach the bottom surface of the COC. Our study can lead to a realistic thermal model describing novel HDI material design criteria for the next generation of hard disk drives with ultra high recording densities.

  7. BEAM INSTRUMENTATION FOR HIGH POWER HADRON BEAMS

    SciTech Connect

    Aleksandrov, Alexander V

    2013-01-01

    This presentation will describe developments in the beam diagnostics which support the understanding and operation of high power hadron accelerators. These include the measurement of large dynamic range transverse and longitudinal beam profiles, beam loss detection, and non-interceptive diagnostics.

  8. Propagation-invariant beams with quantum pendulum spectra: from Bessel beams to Gaussian beam-beams.

    PubMed

    Dennis, Mark R; Ring, James D

    2013-09-01

    We describe a new class of propagation-invariant light beams with Fourier transform given by an eigenfunction of the quantum mechanical pendulum. These beams, whose spectra (restricted to a circle) are doubly periodic Mathieu functions in azimuth, depend on a field strength parameter. When the parameter is zero, pendulum beams are Bessel beams, and as the parameter approaches infinity, they resemble transversely propagating one-dimensional Gaussian wave packets (Gaussian beam-beams). Pendulum beams are the eigenfunctions of an operator that interpolates between the squared angular momentum operator and the linear momentum operator. The analysis reveals connections with Mathieu beams, and insight into the paraxial approximation.

  9. Characterisation of electron beams from laser-driven particle accelerators

    SciTech Connect

    Brunetti, E.; Manahan, G. G.; Shanks, R. P.; Islam, M. R.; Ersfeld, B.; Anania, M. P.; Cipiccia, S.; Issac, R. C.; Vieux, G.; Welsh, G. H.; Wiggins, S. M.; Jaroszynski, D. A.

    2012-12-21

    The development, understanding and application of laser-driven particle accelerators require accurate measurements of the beam properties, in particular emittance, energy spread and bunch length. Here we report measurements and simulations showing that laser wakefield accelerators can produce beams of quality comparable to conventional linear accelerators.

  10. Dual beam translator for use in Laser Doppler anemometry

    DOEpatents

    Brudnoy, D.M.

    1984-04-12

    A method and apparatus for selectively translating the path of at least one pair of light beams in a Laser Doppler anemometry device whereby the light paths are translated in a direction parallel to the original beam paths so as to enable attainment of spacial coincidence of the two intersection volumes and permit accurate measurements of Reynolds shear stress.

  11. Laser beaming demonstrations at the Starfire Optical Range

    SciTech Connect

    Lipinski, R.J.; Meister, D.C.; Tucker, S.; Leatherman, P.; Fugate, R.Q.; Maes, C.; Lange, W.J.; Cowan, W.

    1995-03-01

    The ability to acquire, track, and accurately direct a laser beam to a satellite is crucial for power-beaming and laser-communications. To assess the state of the art in this area, a team consisting of Air Force Phillips Laboratory, Sandia National Laboratories, and COMSAT Corporation personnel performed some laser beaming demonstrations to various satellites. A ruby laser and a frequency-doubled YAG laser were used with the Phillips Lab Starfire Optical Range (SOR) beam director for this activity. The ruby laser projected 20 J in 6 ms out the telescope with a beam divergence that increased from 1.4 to 4 times the diffraction limit during that time. The doubled YAG projected 0.09 J in 10 ns at 20 Hz. The SOR team demonstrated the ability to move rapidly to a satellite, center it in the telescope, then lock onto it with the tracker, and establish illumination. Several low-earth-orbit satellites with corner-cube retro-reflectors were illuminated at ranges from 1000 to 6000 km with a beam divergence estimated to be about 20 {mu}radians. The return signal from the ruby laser was collected in a 15-cm telescope, detected by a photomultiplier tube, and recorded at 400 kHz. Rapid variations in intensity (as short at 15 {mu}s) were noted, which may be due to speckles caused by phase interference from light reflected from different retro-reflectors on the satellite. The return light from the YAG was collected by a 35-cm telescope and detected by an intensified CCD camera. The satellite brightened by about a factor of 30 in the sunlight when the laser was turned on, and dimmed back to normal when the 50-{mu}radian point-ahead was turned off. The satellite was illuminated at 1 Hz as it entered the earth`s shadow and followed for about 10 seconds in the shadow. In another demonstration, four neighboring GEO satellites were located and centered in succession with a 3.5-m telescope at a rate of about 16 seconds per satellite.

  12. 45 CFR 1180.60 - Records related to compliance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Which Must Be Met by a Grantee Records § 1180.60 Records related to compliance. A grantee shall, in accordance with applicable OMB circulars, keep accurate and full records to show its compliance with specific... 45 Public Welfare 3 2014-10-01 2014-10-01 false Records related to compliance. 1180.60...

  13. 45 CFR 1180.60 - Records related to compliance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Which Must Be Met by a Grantee Records § 1180.60 Records related to compliance. A grantee shall, in accordance with applicable OMB circulars, keep accurate and full records to show its compliance with specific... 45 Public Welfare 3 2012-10-01 2012-10-01 false Records related to compliance. 1180.60...

  14. 31 CFR 501.601 - Records and recordkeeping requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... chapter shall keep a full and accurate record of such property, and such record shall be available for... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Records and recordkeeping requirements... REGULATIONS Reports § 501.601 Records and recordkeeping requirements. Except as otherwise provided,...

  15. 45 CFR 1180.60 - Records related to compliance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Which Must Be Met by a Grantee Records § 1180.60 Records related to compliance. A grantee shall, in accordance with applicable OMB circulars, keep accurate and full records to show its compliance with specific... 45 Public Welfare 3 2010-10-01 2010-10-01 false Records related to compliance. 1180.60...

  16. 45 CFR 1180.60 - Records related to compliance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Which Must Be Met by a Grantee Records § 1180.60 Records related to compliance. A grantee shall, in accordance with applicable OMB circulars, keep accurate and full records to show its compliance with specific... 45 Public Welfare 3 2011-10-01 2011-10-01 false Records related to compliance. 1180.60...

  17. 31 CFR 501.601 - Records and recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... chapter shall keep a full and accurate record of such property, and such record shall be available for... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Records and recordkeeping requirements... REGULATIONS Reports § 501.601 Records and recordkeeping requirements. Except as otherwise provided,...

  18. 45 CFR 1180.60 - Records related to compliance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Which Must Be Met by a Grantee Records § 1180.60 Records related to compliance. A grantee shall, in accordance with applicable OMB circulars, keep accurate and full records to show its compliance with specific... 45 Public Welfare 3 2013-10-01 2013-10-01 false Records related to compliance. 1180.60...

  19. Experimental Testing of Dynamically Optimized Photoelectron Beams

    SciTech Connect

    Rosenzweig, J. B.; Cook, A. M.; Dunning, M.; England, R. J.; Musumeci, P.; Bellaveglia, M.; Boscolo, M.; Catani, L.; Cianchi, A.; Di Pirro, G.; Ferrario, M.; Fillipetto, D.; Gatti, G.; Palumbo, L.; Vicario, C.; Serafini, L.; Jones, S.

    2006-11-27

    We discuss the design of and initial results from an experiment in space-charge dominated beam dynamics which explores a new regime of high-brightness electron beam generation at the SPARC photoinjector. The scheme under study employs the tendency of intense electron beams to rearrange to produce uniform density, giving a nearly ideal beam from the viewpoint of space charge-induced emittance. The experiments are aimed at testing the marriage of this idea with a related concept, emittance compensation. We show that this new regime of operating photoinjector may be the preferred method of obtaining highest brightness beams with lower energy spread. We discuss the design of the experiment, including developing of a novel time-dependent, aerogel-based imaging system. This system has been installed at SPARC, and first evidence for nearly uniformly filled ellipsoidal charge distributions recorded.

  20. Experimental Testing of Dynamically Optimized Photoelectron Beams

    NASA Astrophysics Data System (ADS)

    Rosenzweig, J. B.; Cook, A. M.; Dunning, M.; England, R. J.; Musumeci, P.; Bellaveglia, M.; Boscolo, M.; Catani, L.; Cianchi, A.; Di Pirro, G.; Ferrario, M.; Fillipetto, D.; Gatti, G.; Palumbo, L.; Serafini, L.; Vicario, C.; Jones, S.

    2006-11-01

    We discuss the design of and initial results from an experiment in space-charge dominated beam dynamics which explores a new regime of high-brightness electron beam generation at the SPARC photoinjector. The scheme under study employs the tendency of intense electron beams to rearrange to produce uniform density, giving a nearly ideal beam from the viewpoint of space charge-induced emittance. The experiments are aimed at testing the marriage of this idea with a related concept, emittance compensation. We show that this new regime of operating photoinjector may be the preferred method of obtaining highest brightness beams with lower energy spread. We discuss the design of the experiment, including developing of a novel time-dependent, aerogel-based imaging system. This system has been installed at SPARC, and first evidence for nearly uniformly filled ellipsoidal charge distributions recorded.

  1. Antenna Beam Coverage Concepts

    NASA Technical Reports Server (NTRS)

    Estabrook, Polly; Motamedi, Masoud

    1990-01-01

    The strawman Personal Access Satellite System (PASS) design calls for the use of a CONUS beam for transmission between the supplier and the satellite and for fixed beams for transmission between the basic personal terminal and the satellite. The satellite uses a 3 m main reflector for transmission at 20 GHz and a 2 m main reflector for reception at 30 GHz. There are several types of spot beams under consideration for the PASS system besides fixed beams. The beam pattern of a CONUS coverage switched beam is shown along with that of a scanning beam. A switched beam refers to one in which the signal from the satellite is connected alternatively to various feed horns. Scanning beams are taken to mean beams whose footprints are moved between contiguous regions in the beam's coverage area. The advantages and disadvantages of switched and/or scanning beams relative to fixed beams. The consequences of using switched/scanning in lieu of fixed beams in the PASS design and attempts are made to evaluate the listed advantages and disadvantages. Two uses of switched/scanning beams are examined. To illustrate the implications of switched beams use on PASS system design, operation at two beam scan rates is explored.

  2. LRSP resonance enhanced spatial and angular Goos-Hanchen shift and Imbert-Fedorov shift for Gaussian beam, Laguerre-Gaussian beam and Bessel beam

    NASA Astrophysics Data System (ADS)

    Swain, Prasad Kumar; Goswami, Nabamita; Saha, Ardhendu

    2017-01-01

    A new theoretical approach towards the composite effect of spatial and angular Goos-Hanchen (GH) shift and Imbert-Fedorov (IF) shift for the Gaussian beam, Laguerre-Gaussian beam and Bessel beam with long range surface plasmon (LRSP) resonance is observed, designed and simulated through the variation of incident angle at a wavelength of 1550 nm where the four layered Kreschmann-Rather geometry comprises a ZnSe prism, a liquid crystal layer of E44 and two metal layers of silver. To the best of our knowledge several articles have been devoted, separately considering the Gaussian beam, Laguerre-Gaussian beam and Bessel beam without considering the effect of spatial and angular GH shift and IF shift whereas the exact output beam position can only be identified with the composite effect of these shifts. The investigation of these spatial and angular shifts for Gaussian beam and different orders of Laguerre-Gaussian beam are calculated and represented where these lateral shifts increase with the increment of the modes and further these lateral shifts for Bessel beam have also been analyzed. With this new approach various avenues expedite the way of futuristic applications in the field of fine tuning in optical switching with the accurate beam position using different beams.

  3. 42 CFR 60.56 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS HEALTH EDUCATION ASSISTANCE LOAN PROGRAM The School § 60.56 Records. (a) In addition to complying with the requirements of section 739(b) of the Act, each school must maintain an accurate, complete, and easily retrievable record with...

  4. 42 CFR 60.56 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS HEALTH EDUCATION ASSISTANCE LOAN PROGRAM The School § 60.56 Records. (a) In addition to complying with the requirements of section 739(b) of the Act, each school must maintain an accurate, complete, and easily retrievable record with...

  5. 12 CFR 347.205 - Record maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... English language that accurately reflects the business transactions of the insured branch on a daily basis... INTERNATIONAL BANKING Foreign Banks § 347.205 Record maintenance. The records of each insured branch shall be... operations of the head office, other branches or agencies of the foreign bank and its subsidiaries...

  6. 7 CFR 989.176 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false Records. 989.176 Section 989.176 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... maintain complete, accurate, and current records of all of his business affairs concerning which he...

  7. 7 CFR 989.176 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Records. 989.176 Section 989.176 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... maintain complete, accurate, and current records of all of his business affairs concerning which he...

  8. 7 CFR 989.176 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Records. 989.176 Section 989.176 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... maintain complete, accurate, and current records of all of his business affairs concerning which he...

  9. 50 CFR 20.82 - Records required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PLANTS (CONTINUED) MIGRATORY BIRD HUNTING Migratory Bird Preservation Facilities § 20.82 Records required. (a) No migratory bird preservation facility shall: (1) Receive or have in custody any migratory game bird unless accurate records are maintained which can identify each bird received by, or in the...

  10. 50 CFR 20.82 - Records required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PLANTS (CONTINUED) MIGRATORY BIRD HUNTING Migratory Bird Preservation Facilities § 20.82 Records required. (a) No migratory bird preservation facility shall: (1) Receive or have in custody any migratory game bird unless accurate records are maintained which can identify each bird received by, or in the...

  11. 50 CFR 20.82 - Records required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PLANTS (CONTINUED) MIGRATORY BIRD HUNTING Migratory Bird Preservation Facilities § 20.82 Records required. (a) No migratory bird preservation facility shall: (1) Receive or have in custody any migratory game bird unless accurate records are maintained which can identify each bird received by, or in the...

  12. 50 CFR 20.82 - Records required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PLANTS (CONTINUED) MIGRATORY BIRD HUNTING Migratory Bird Preservation Facilities § 20.82 Records required. (a) No migratory bird preservation facility shall: (1) Receive or have in custody any migratory game bird unless accurate records are maintained which can identify each bird received by, or in the...

  13. 50 CFR 20.82 - Records required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PLANTS (CONTINUED) MIGRATORY BIRD HUNTING Migratory Bird Preservation Facilities § 20.82 Records required. (a) No migratory bird preservation facility shall: (1) Receive or have in custody any migratory game bird unless accurate records are maintained which can identify each bird received by, or in the...

  14. 50 CFR 37.52 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... WILDLIFE REFUGE, ALASKA Reporting and Data Management § 37.52 Records. The permittee shall keep accurate and complete records relating to its exploratory activities and to all data and information, including, but not limited to, raw, processed, reprocessed, analyzed and interpreted data and...

  15. 50 CFR 37.52 - Records.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... WILDLIFE REFUGE, ALASKA Reporting and Data Management § 37.52 Records. The permittee shall keep accurate and complete records relating to its exploratory activities and to all data and information, including, but not limited to, raw, processed, reprocessed, analyzed and interpreted data and...

  16. 50 CFR 37.52 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... WILDLIFE REFUGE, ALASKA Reporting and Data Management § 37.52 Records. The permittee shall keep accurate and complete records relating to its exploratory activities and to all data and information, including, but not limited to, raw, processed, reprocessed, analyzed and interpreted data and...

  17. 50 CFR 37.52 - Records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... WILDLIFE REFUGE, ALASKA Reporting and Data Management § 37.52 Records. The permittee shall keep accurate and complete records relating to its exploratory activities and to all data and information, including, but not limited to, raw, processed, reprocessed, analyzed and interpreted data and...

  18. 50 CFR 37.52 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... WILDLIFE REFUGE, ALASKA Reporting and Data Management § 37.52 Records. The permittee shall keep accurate and complete records relating to its exploratory activities and to all data and information, including, but not limited to, raw, processed, reprocessed, analyzed and interpreted data and...

  19. 27 CFR 19.829 - Daily records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Production of Vinegar by the Vaporizing Process Records § 19.829 Daily records. Each manufacturer of vinegar by the vaporizing process shall keep accurate... spirits used in the manufacture of vinegar; (e) The wine gallons of vinegar produced; and (f) The...

  20. A symplectic coherent beam-beam model

    SciTech Connect

    Furman, M.A.

    1989-05-01

    We consider a simple one-dimensional model to study the effects of the beam-beam force on the coherent dynamics of colliding beams. The key ingredient is a linearized beam-beam kick. We study only the quadrupole modes, with the dynamical variables being the 2nd-order moments of the canonical variables q, p. Our model is self-consistent in the sense that no higher order moments are generated by the linearized beam-beam kicks, and that the only source of violation of symplecticity is the radiation. We discuss the round beam case only, in which vertical and horizontal quantities are assumed to be equal (though they may be different in the two beams). Depending on the values of the tune and beam intensity, we observe steady states in which otherwise identical bunches have sizes that are equal, or unequal, or periodic, or behave chaotically from turn to turn. Possible implications of luminosity saturation with increasing beam intensity are discussed. Finally, we present some preliminary applications to an asymmetric collider. 8 refs., 8 figs.

  1. Accurate oscillator strengths for interstellar ultraviolet lines of Cl I

    NASA Technical Reports Server (NTRS)

    Schectman, R. M.; Federman, S. R.; Beideck, D. J.; Ellis, D. J.

    1993-01-01

    Analyses on the abundance of interstellar chlorine rely on accurate oscillator strengths for ultraviolet transitions. Beam-foil spectroscopy was used to obtain f-values for the astrophysically important lines of Cl I at 1088, 1097, and 1347 A. In addition, the line at 1363 A was studied. Our f-values for 1088, 1097 A represent the first laboratory measurements for these lines; the values are f(1088)=0.081 +/- 0.007 (1 sigma) and f(1097) = 0.0088 +/- 0.0013 (1 sigma). These results resolve the issue regarding the relative strengths for 1088, 1097 A in favor of those suggested by astronomical measurements. For the other lines, our results of f(1347) = 0.153 +/- 0.011 (1 sigma) and f(1363) = 0.055 +/- 0.004 (1 sigma) are the most precisely measured values available. The f-values are somewhat greater than previous experimental and theoretical determinations.

  2. Mill profiler machines soft materials accurately

    NASA Technical Reports Server (NTRS)

    Rauschl, J. A.

    1966-01-01

    Mill profiler machines bevels, slots, and grooves in soft materials, such as styrofoam phenolic-filled cores, to any desired thickness. A single operator can accurately control cutting depths in contour or straight line work.

  3. Telecommunication using muon beams

    DOEpatents

    Arnold, Richard C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location.

  4. LANSCE beam current limiter

    SciTech Connect

    Gallegos, F.R.

    1996-06-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. Active instrumentation, such as the Beam Current Limiter, is a component of the RSS. The current limiter is designed to limit the average current in a beam line below a specific level, thus minimizing the maximum current available for a beam spill accident. The beam current limiter is a self-contained, electrically isolated toroidal beam transformer which continuously monitors beam current. It is designed as fail-safe instrumentation. The design philosophy, hardware design, operation, and limitations of the device are described.

  5. Accurate Measurement of Bone Density with QCT

    NASA Technical Reports Server (NTRS)

    Cleek, Tammy M.; Beaupre, Gary S.; Matsubara, Miki; Whalen, Robert T.; Dalton, Bonnie P. (Technical Monitor)

    2002-01-01

    The objective of this study was to determine the accuracy of bone density measurement with a new OCT technology. A phantom was fabricated using two materials, a water-equivalent compound and hydroxyapatite (HA), combined in precise proportions (QRM GrnbH, Germany). The phantom was designed to have the approximate physical size and range in bone density as a human calcaneus, with regions of 0, 50, 100, 200, 400, and 800 mg/cc HA. The phantom was scanned at 80, 120 and 140 KVp with a GE CT/i HiSpeed Advantage scanner. A ring of highly attenuating material (polyvinyl chloride or teflon) was slipped over the phantom to alter the image by introducing non-axi-symmetric beam hardening. Images were corrected with a new OCT technology using an estimate of the effective X-ray beam spectrum to eliminate beam hardening artifacts. The algorithm computes the volume fraction of HA and water-equivalent matrix in each voxel. We found excellent agreement between expected and computed HA volume fractions. Results were insensitive to beam hardening ring material, HA concentration, and scan voltage settings. Data from all 3 voltages with a best fit linear regression are displays.

  6. Beam characterization of FLASH from beam profile measurement by intensity transport equation and reconstruction of the Wigner distribution function

    NASA Astrophysics Data System (ADS)

    Schäfer, Bernd; Mey, Tobias; Mann, Klaus; Keitel, Barbara; Kreis, Svea; Kuhlmann, Marion; Plönjes, Elke; Tiedtke, Kai

    2013-05-01

    Beam parameters of the free-electron laser FLASH @13.5 nm in two different operation modes were determined from beam profile measurements and subsequent reconstruction of the Wigner distribution function behind the ellipsoidal focusing mirror at beamline BL2. 40 two-dimensional single pulse intensity distributions were recorded at each of 65 axial positions around the waist of the FEL beam with a magnifying EUV sensitized CCD camera. From these beam profile data the Wigner distribution function based on different levels of averaging could be reconstructed by an inverse Radon transform. For separable beams this yields the complete Wigner distribution, and for beams with zero twist the information is still sufficient for wavefront determination and beam propagation through stigmatic systems. The obtained results are compared to wavefront reconstructions based on the transport of intensity equation. A future setup for Wigner distribution measurements of general beams is discussed.

  7. 21 CFR 312.57 - Recordkeeping and record retention.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... batch or code mark of each such shipment. (b) A sponsor shall maintain complete and accurate records... complete and accurate records concerning all other financial interests of investigators subject to part 54... after a marketing application is approved for the drug; or, if an application is not approved for...

  8. 77 FR 49859 - Proposed Traffic Records Program Assessment Advisory

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-17

    ... inform highway and traffic safety decision-making. States need timely, accurate, complete, and uniform.... SUPPLEMENTARY INFORMATION: Timely, accurate, complete, and uniform traffic records data is needed to identify... strengths and weaknesses of each component of the State's traffic records systems and provide the State...

  9. SUMMARY OF BEAM BEAM OBSERVATIONS DURING STORES IN RHIC.

    SciTech Connect

    FISCHER,W.

    2003-05-19

    During stores, the beam-beam interaction has a significant impact on the beam and luminosity lifetimes in RHIC. This was observed in heavy ion, and even more pronounced in proton collisions. Observations include measurements of beam-beam induced tune shifts, lifetime and emittance growth measurements with and without beam-beam interaction, and background rates as a function of tunes. In addition, RHIC is currently the only hadron collider in which strong-strong beam-beam effects can be seen. Coherent beam-beam modes were observed, and suppressed by tune changes. In this article we summarize the most important beam-beam observations made during stores so far.

  10. Quadrant-division technique for differential sensitivity optical beam measurement

    NASA Astrophysics Data System (ADS)

    Hii, K. U.

    2016-11-01

    A novel method for optical beam collimation measurement is presented. The collimating lens is utilized in four parts of quadrants with the beam aligned onto the first quadrant and configured to pass the subsequent quadrants. This allows the test beam to pass the collimating lens for four times. Subsequently, the test beam is reversed to achieve a total number of eight passes. Hence, for a defocus introduced, the collimation state of the test beam can be evaluated at the amplification of eight. The evaluation of the test beam is performed based on the approach of collimation testing using lateral shearing interferometer. The proposed technique provides a differential collimation sensitivity for accurate setting of a highly collimated beam.

  11. Formation of buffer-gas-trap based positron beams

    SciTech Connect

    Natisin, M. R. Danielson, J. R. Surko, C. M.

    2015-03-15

    Presented here are experimental measurements, analytic expressions, and simulation results for pulsed, magnetically guided positron beams formed using a Penning-Malmberg style buffer gas trap. In the relevant limit, particle motion can be separated into motion along the magnetic field and gyro-motion in the plane perpendicular to the field. Analytic expressions are developed which describe the evolution of the beam energy distributions, both parallel and perpendicular to the magnetic field, as the beam propagates through regions of varying magnetic field. Simulations of the beam formation process are presented, with the parameters chosen to accurately replicate experimental conditions. The initial conditions and ejection parameters are varied systematically in both experiment and simulation, allowing the relevant processes involved in beam formation to be explored. These studies provide new insights into the underlying physics, including significant adiabatic cooling, due to the time-dependent beam-formation potential. Methods to improve the beam energy and temporal resolution are discussed.

  12. Partially coherent nonparaxial beams.

    PubMed

    Duan, Kailiang; Lü, Baida

    2004-04-15

    The concept of a partially coherent nonparaxial beam is proposed. A closed-form expression for the propagation of nonparaxial Gaussian Schell model (GSM) beams in free space is derived and applied to study the propagation properties of nonparaxial GSM beams. It is shown that for partially coherent nonparaxial beams a new parameter f(sigma) has to be introduced, which together with the parameter f, determines the beam nonparaxiality.

  13. Automated beam builder

    NASA Technical Reports Server (NTRS)

    Muench, W. K.

    1980-01-01

    Requirements for the space fabrication of large space structures are considered with emphasis on the design, development, manufacture, and testing of a machine which automatically produces a basic building block aluminum beam. Particular problems discussed include those associated with beam cap forming; brace storage, dispensing, and transporting; beam component fastening; and beam cut-off. Various critical process tests conducted to develop technology for a machine to produce composite beams are also discussed.

  14. A ray-tracing backprojection algorithm for cone beam CT

    NASA Astrophysics Data System (ADS)

    Lu, Jun; Pan, Tinsu

    2007-03-01

    We have developed a ray-tracing backprojection (RTB) to back-project all the detector pixels into the image domain of cone beam CT (CBCT). The underlying mathematic framework is the FDK reconstruction. In this method, every ray recorded by the flat panel detector is traced back into the image space. In each voxel of the imaging domain, all the rays contributing to the formation of the CT image are summed together weighted by each rays' intersection length with the voxel. The RTB is similar to a reverse process of x-ray transmission imaging, as opposed to the conventional voxel-driven backprojection (VDB). In the RTB, we avoided interpolation and pixel binning approximations, achieved better spatial resolution and eliminated some image artifacts. We have successfully applied the RTB in phantom studies on the Varian On Board Imager CBCT. The images of the Catphan CTP404 module show more accurate representation of the oblique ramps in the measurement of slice thickness, and more accurate determination of slice thickness with the RTB than with VDB. The RTB also shows higher spatial resolution than the VDB in the studies of a high contrast resolution phantom.

  15. Vibration of beams and plate strips with three-dimensional flexibility

    NASA Technical Reports Server (NTRS)

    Stein, Manuel

    1989-01-01

    Studies making use of higher vibration modes and frequencies have indicated a need for a more accurate beam theory. Equations of motion are developed here that give a more accurate representation of the dynamic behavior of a beam than conventional beam theory. Results are obtained using these equations for the natural vibrations of simply-supported aluminum beams of rectangular cross-sections. These results are compared to results from conventional beam theory, and they are examined to identify where various effects are important.

  16. RTbox: a device for highly accurate response time measurements.

    PubMed

    Li, Xiangrui; Liang, Zhen; Kleiner, Mario; Lu, Zhong-Lin

    2010-02-01

    Although computer keyboards and mice are frequently used in measuring response times (RTs), the accuracy of these measurements is quite low. Specialized RT collection devices must be used to obtain more accurate measurements. However, all the existing devices have some shortcomings. We have developed and implemented a new, commercially available device, the RTbox, for highly accurate RT measurements. The RTbox has its own microprocessor and high-resolution clock. It can record the identities and timing of button events with high accuracy, unaffected by potential timing uncertainty or biases during data transmission and processing in the host computer. It stores button events until the host computer chooses to retrieve them. The asynchronous storage greatly simplifies the design of user programs. The RTbox can also receive and record external signals as triggers and can measure RTs with respect to external events. The internal clock of the RTbox can be synchronized with the computer clock, so the device can be used without external triggers. A simple USB connection is sufficient to integrate the RTbox with any standard computer and operating system.

  17. Discrete sensors distribution for accurate plantar pressure analyses.

    PubMed

    Claverie, Laetitia; Ille, Anne; Moretto, Pierre

    2016-12-01

    The aim of this study was to determine the distribution of discrete sensors under the footprint for accurate plantar pressure analyses. For this purpose, two different sensor layouts have been tested and compared, to determine which was the most accurate to monitor plantar pressure with wireless devices in research and/or clinical practice. Ten healthy volunteers participated in the study (age range: 23-58 years). The barycenter of pressures (BoP) determined from the plantar pressure system (W-inshoe®) was compared to the center of pressures (CoP) determined from a force platform (AMTI) in the medial-lateral (ML) and anterior-posterior (AP) directions. Then, the vertical ground reaction force (vGRF) obtained from both W-inshoe® and force platform was compared for both layouts for each subject. The BoP and vGRF determined from the plantar pressure system data showed good correlation (SCC) with those determined from the force platform data, notably for the second sensor organization (ML SCC= 0.95; AP SCC=0.99; vGRF SCC=0.91). The study demonstrates that an adjusted placement of removable sensors is key to accurate plantar pressure analyses. These results are promising for a plantar pressure recording outside clinical or laboratory settings, for long time monitoring, real time feedback or for whatever activity requiring a low-cost system.

  18. Accurately measuring volcanic plume velocity with multiple UV spectrometers

    USGS Publications Warehouse

    Williams-Jones, Glyn; Horton, Keith A.; Elias, Tamar; Garbeil, Harold; Mouginis-Mark, Peter J; Sutton, A. Jeff; Harris, Andrew J. L.

    2006-01-01

    A fundamental problem with all ground-based remotely sensed measurements of volcanic gas flux is the difficulty in accurately measuring the velocity of the gas plume. Since a representative wind speed and direction are used as proxies for the actual plume velocity, there can be considerable uncertainty in reported gas flux values. Here we present a method that uses at least two time-synchronized simultaneously recording UV spectrometers (FLYSPECs) placed a known distance apart. By analyzing the time varying structure of SO2 concentration signals at each instrument, the plume velocity can accurately be determined. Experiments were conducted on Kīlauea (USA) and Masaya (Nicaragua) volcanoes in March and August 2003 at plume velocities between 1 and 10 m s−1. Concurrent ground-based anemometer measurements differed from FLYSPEC-measured plume speeds by up to 320%. This multi-spectrometer method allows for the accurate remote measurement of plume velocity and can therefore greatly improve the precision of volcanic or industrial gas flux measurements.

  19. Accurate Feeding of Nanoantenna by Singular Optics for Nanoscale Translational and Rotational Displacement Sensing

    NASA Astrophysics Data System (ADS)

    Xi, Zheng; Wei, Lei; Adam, A. J. L.; Urbach, H. P.; Du, Luping

    2016-09-01

    Identifying subwavelength objects and displacements is of crucial importance in optical nanometrology. We show in this Letter that nanoantennas with subwavelength structures can be excited precisely by incident beams with singularity. This accurate feeding beyond the diffraction limit can lead to dynamic control of the unidirectional scattering in the far field. The combination of the field discontinuity of the incoming singular beam with the rapid phase variation near the antenna leads to remarkable sensitivity of the far-field scattering to the displacement at a scale much smaller than the wavelength. This Letter introduces a far-field deep subwavelength position detection method based on the interaction of singular optics with nanoantennas.

  20. Tevatron beam-beam compensation project progress

    SciTech Connect

    Shiltsev, V.; Zhang, X.L.; Kuznetsov, G.; Pfeffer, H.; Saewert, G.; Zimmermann, F.; Tiunov, M.; Bishofberger, K.; Bogdanov, I.; Kashtanov, E.; Kozub, S.; Sytnik, V.; Tkachenko, L.; /Serpukhov, IHEP

    2005-05-01

    In this paper, we report the progress of the Tevatron Beam-Beam Compensation (BBC) project [1]. Electron beam induced proton and antiproton tuneshifts have been reported in [2], suppression of an antiproton emittance growth has been observed, too [1]. Currently, the first electron lens (TEL1) is in operational use as the Tevatron DC beam cleaner. We have made a lot of the upgrades to improve its stability [3]. The 2nd Tevatron electron lens (TEL2) is under the final phase of development and preparation for installation in the Tevatron.

  1. Large Deformation Dynamic Bending of Composite Beams

    NASA Technical Reports Server (NTRS)

    Derian, E. J.; Hyer, M. W.

    1986-01-01

    Studies were conducted on the large deformation response of composite beams subjected to a dynamic axial load. The beams were loaded with a moderate eccentricity to promote bending. The study was primarily experimental but some finite element results were obtained. Both the deformation and the failure of the beams were of interest. The static response of the beams was also studied to determine potential differences between the static and dynamic failure. Twelve different laminate types were tested. The beams tested were 23 in. by 2 in. and generally 30 plies thick. The beams were loaded dynamically with a gravity-driven impactor traveling at 19.6 ft/sec and quasi-static tests were conducted on identical beams in a displacement controlled manner. For laminates of practical interest, the failure modes under static and dynamic loadings were identical. Failure in most of the laminate types occurred in a single event involving 40% to 50% of the plies. However, failure in laminates with 300 or 150 off-axis plies occurred in several events. All laminates exhibited bimodular elastic properties. The compressive flexural moduli in some laminates was measured to be 1/2 the tensile flexural modulus. No simple relationship could be found among the measured ultimate failure strains of the different laminate types. Using empirically determined flexural properties, a finite element analysis was reasonably accurate in predicting the static and dynamic deformation response.

  2. Medical records and access thereto.

    PubMed

    McQuoid-Mason, D

    1996-01-01

    Medical records are essential tools in the practice of medicine. They are important in the planning and monitoring of patient care and for the protection of the legal interests of patients, hospitals and doctors. There is a legal duty on doctors to maintain confidentiality and failure to do so may result in an action for invasion of privacy, defamation or even breach of contract. There are, however, exceptions to this rule. There are procedural remedies available to obtain access to medical records where they are relevant to civil or criminal proceedings. There are also constitutional provisions under the Interim and Working Draft Constitutions which may allow such access. The former only applies to records held by the state while the latter applies to both state and privately held records. Ownership of medical records usually vests in the doctor or institution treating the patient, but such ownership is custodial rather than absolute. Patient records should be accurate, objective and contemporaneous. The international trend is to allow patients to inspect their records and to allow them to make copies thereof. It is submitted that given the provisions of the Interim and Working Draft Constitutions the same should apply in South Africa.

  3. Non-uniform beam vibration using Differential Transform Method

    NASA Astrophysics Data System (ADS)

    Shali, S.; Nagaraja, S. R.; Jafarali, P.

    2016-09-01

    The paper focuses on the vibration characteristics of non-uniform Euler- Bernoulli beam using Differential Transform Method (DTM). DTM is a numerical method to solve differential equations where the governing equations are reduced into a set of polynomials. Non-uniformity is considered corresponding to linear variation in breadth and height of the beam. The effect of taper ratio on the fundamental frequency of tapered beams is also analysed. The method has proved to be accurate, simple and effective for eigenvalue analysis. For the two cases of non-uniform beam analysed, the frequency computed by the method of differential transform is found to be comparable with the previously available results.

  4. Segmented ionization chambers for beam monitoring in hadrontherapy

    NASA Astrophysics Data System (ADS)

    Braccini, Saverio; Cirio, Roberto; Donetti, Marco; Marchetto, Flavio; Pittà, Giuseppe; Lavagno, Marco; La Rosa, Vanessa

    2015-05-01

    Segmented ionization chambers represent a good solution to monitor the position, the intensity and the shape of ion beams in hadrontherapy. Pixel and strip chambers have been developed for both passive scattering and active scanning dose delivery systems. In particular, strip chambers are optimal for pencil beam scanning, allowing for spatial and time resolutions below 0.1 mm and 1 ms, respectively. The MATRIX pixel and the Strip Accurate Monitor for Beam Applications (SAMBA) detectors are described in this paper together with the results of several beam tests and industrial developments based on these prototypes.

  5. Beam position monitor

    DOEpatents

    Alkire, Randy W.; Rosenbaum, Gerold; Evans, Gwyndaf

    2003-07-22

    An apparatus for determining the position of an x-ray beam relative to a desired beam axis. Where the apparatus is positioned along the beam path so that a thin metal foil target intersects the x-ray beam generating fluorescent radiation. A PIN diode array is positioned so that a portion of the fluorescent radiation is intercepted by the array resulting in an a series of electrical signals from the PIN diodes making up the array. The signals are then analyzed and the position of the x-ray beam is determined relative to the desired beam path.

  6. LANSCE beam current limiter

    SciTech Connect

    Gallegos, F.R.

    1997-01-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. Active instrumentation, such as the beam current limiter, is a component of the RSS. The current limiter is designed to limit the average current in a beamline below a specific level, thus minimizing the maximum current available for a beam spill accident. The beam current limiter is a self-contained, electrically isolated toroidal beam transformer which continuously monitors beam current. It is designed as fail-safe instrumentation. The design philosophy, hardware design, operation, and limitations of the device are described. {copyright} {ital 1997 American Institute of Physics.}

  7. Beam position monitor

    SciTech Connect

    Alkire, Randy W.; Rosenbaum, Gerold; Evans, Gwyndaf

    2000-09-21

    An apparatus for determining the position of an x-ray beam relative to a desired beam axis where the apparatus is positioned along the beam path so that a thin metal foil target intersects the x-ray beam generating fluorescent radiation. A PIN diode array is positioned so that a portion of the fluorescent radiation is intercepted by the array resulting in a series of electrical signals from the PIN diodes making up the array. The signals are then analyzed and the position of the x-ray beam is determined relative to the desired beam path.

  8. Thermomagnetic recording and magnetic-optic playback system

    NASA Technical Reports Server (NTRS)

    Lewicki, G. W.; Guisinger, J. E. (Inventor)

    1971-01-01

    A magnetic recording and magneto-optic playback system is disclosed wherein thermomagnetic recording is employed. A transparent isotropic film is heated along a continuous path by a focused laser beam. As each successive area of the path is heated locally to the vicinity of its Curie point in the presence of an applied magnetic field, a magneto-optic density is established proportional to the magnetic field and fixed in place as the area cools once the laser beam moves on to an adjacent area. To play back the recorded data, the intensity of the laser beam is reduced to avoid reaching the vicinity of the Curie point of the film as it is scanned by the laser beam in the same manner as for recording. A Faraday effect analyzer and photo detector are employed as a transducer for producing an output signal.

  9. Accurate pointing of tungsten welding electrodes

    NASA Technical Reports Server (NTRS)

    Ziegelmeier, P.

    1971-01-01

    Thoriated-tungsten is pointed accurately and quickly by using sodium nitrite. Point produced is smooth and no effort is necessary to hold the tungsten rod concentric. The chemically produced point can be used several times longer than ground points. This method reduces time and cost of preparing tungsten electrodes.

  10. Beam-beam issues in asymmetric colliders

    SciTech Connect

    Furman, M.A.

    1992-07-01

    We discuss generic beam-beam issues for proposed asymmetric e{sup +}- e{sup -} colliders. We illustrate the issues by choosing, as examples, the proposals by Cornell University (CESR-B), KEK, and SLAC/LBL/LLNL (PEP-II).

  11. Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission

    SciTech Connect

    Chrystal, C.; Burrell, K. H.; Pace, D. C.; Grierson, B. A.

    2015-10-15

    Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.

  12. Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission.

    PubMed

    Chrystal, C; Burrell, K H; Grierson, B A; Pace, D C

    2015-10-01

    Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.

  13. Beam angle selection incorporation of anatomical heterogeneities for pencil beam scanning charged-particle therapy

    NASA Astrophysics Data System (ADS)

    Toramatsu, Chie; Inaniwa, Taku

    2016-12-01

    In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. The sensitivity of a PBS plan to lateral tissue heterogeneities can be reduced by selecting appropriate beam angles. The purpose of this study is to develop a fast and accurate method of beam angle selection for PBS. The lateral tissue heterogeneity surrounding the path of the pencil beams at a given angle was quantified with the heterogeneity number representing the variation of the Bragg peak depth across the cross section of the beams using the stopping power ratio of body tissues with respect to water. To shorten the computation time, one-dimensional dose optimization was conducted along the central axis of the pencil beams as they were directed by the scanning magnets. The heterogeneity numbers were derived for all possible beam angles for treatment. The angles leading to the minimum mean heterogeneity number were selected as the optimal beam angle. Three clinical cases of head and neck cancer were used to evaluate the developed method. Dose distributions and their robustness to setup and range errors were evaluated for all tested angles, and their relation to the heterogeneity numbers was investigated. The mean heterogeneity number varied from 1.2 mm-10.6 mm in the evaluated cases. By selecting a field with a low mean heterogeneity number, target dose coverage and robustness against setup and range errors were improved. The developed method is simple, fast, accurate and applicable for beam angle selection in charged particle therapy with PBS.

  14. BEAMS3D Neutral Beam Injection Model

    SciTech Connect

    Lazerson, Samuel

    2014-04-14

    With the advent of applied 3D fi elds in Tokamaks and modern high performance stellarators, a need has arisen to address non-axisymmetric effects on neutral beam heating and fueling. We report on the development of a fully 3D neutral beam injection (NBI) model, BEAMS3D, which addresses this need by coupling 3D equilibria to a guiding center code capable of modeling neutral and charged particle trajectories across the separatrix and into the plasma core. Ionization, neutralization, charge-exchange, viscous velocity reduction, and pitch angle scattering are modeled with the ADAS atomic physics database [1]. Benchmark calculations are presented to validate the collisionless particle orbits, neutral beam injection model, frictional drag, and pitch angle scattering effects. A calculation of neutral beam heating in the NCSX device is performed, highlighting the capability of the code to handle 3D magnetic fields.

  15. Successful Beam-Beam Tuneshift Compensation

    SciTech Connect

    Bishofberger, Kip Aaron

    2005-01-01

    The performance of synchrotron colliders has been limited by the beam-beam limit, a maximum tuneshift that colliding bunches could sustain. Due to bunch-to-bunch tune variation and intra-bunch tune spread, larger tuneshifts produce severe emittance growth. Breaking through this constraint has been viewed as impossible for several decades. This dissertation introduces the physics of ultra-relativistic synchrotrons and low-energy electron beams, with emphasis placed on the limits of the Tevatron and the needs of a tuneshift-compensation device. A detailed analysis of the Tevatron Electron Lens (TEL) is given, comparing theoretical models to experimental data whenever possible. Finally, results of Tevatron operations with inclusion of the TEL are presented and analyzed. It is shown that the TEL provides a way to shatter the previously inescapable beam-beam limit.

  16. Simulation of transition radiation based beam imaging from tilted targets

    NASA Astrophysics Data System (ADS)

    Sukhikh, L. G.; Kube, G.; Potylitsyn, A. P.

    2017-03-01

    Transverse beam profile diagnostics in linear electron accelerators is usually based on direct imaging of a beam spot via visible transition radiation. In this case the fundamental resolution limit is determined by radiation diffraction in the optical system. A method to measure beam sizes beyond the diffraction limit is to perform imaging dominated by a single-particle function (SPF), i.e. when the recorded image is dominated not by the transverse beam profile but by the image function of a point source (single electron). Knowledge of the SPF for an experimental setup allows one to extract the transverse beam size from an SPF dominated image. This paper presents an approach that allows one to calculate two-dimensional SPF dominated beam images, taking into account the target inclination angle and the depth-of-field effect. In conclusion, a simple fit function for beam size determination in the case under consideration is proposed and its applicability is tested under various conditions.

  17. The Photographic Recording of Small Motions

    NASA Technical Reports Server (NTRS)

    Norton, F H

    1920-01-01

    Methods and equipment for recording small and sometimes rapid motions by photographic means are described, and the efficacy of photographic recording in such instances is evaluated. The optical system consisting of the light source, the mirror or prism for transmitting motion to the emergent beam, and a means of bringing the rays into focus on the film are discussed. Attention is given to the critical issue of mirror mounting. The film holder and the driving motor for the recording drum are described in detail. The authors conclude that the optical methods they describe are far more satisfactory than the recording pen, in compactness, in high natural period, and in elimination of friction. Costs are similar to mechanical methods. The development and reproduction of the record is an added complication, but the ease of duplicating the records is a decided advantage.

  18. Final Report for "Accurate Numerical Models of the Secondary Electron Yield from Grazing-incidence Collisions".

    SciTech Connect

    Seth A Veitzer

    2008-10-21

    Effects of stray electrons are a main factor limiting performance of many accelerators. Because heavy-ion fusion (HIF) accelerators will operate in regimes of higher current and with walls much closer to the beam than accelerators operating today, stray electrons might have a large, detrimental effect on the performance of an HIF accelerator. A primary source of stray electrons is electrons generated when halo ions strike the beam pipe walls. There is some research on these types of secondary electrons for the HIF community to draw upon, but this work is missing one crucial ingredient: the effect of grazing incidence. The overall goal of this project was to develop the numerical tools necessary to accurately model the effect of grazing incidence on the behavior of halo ions in a HIF accelerator, and further, to provide accurate models of heavy ion stopping powers with applications to ICF, WDM, and HEDP experiments.

  19. Electron Beam Freeform Fabrication

    NASA Video Gallery

    Electron Beam Freeform Fabrication (EBF3) is a process by which NASA hopes to build metal parts in zero gravity environments. It's a layer-additive process that uses an electron beam and a solid wi...

  20. High energy beam lines

    NASA Astrophysics Data System (ADS)

    Marchetto, M.; Laxdal, R. E.

    2014-01-01

    The ISAC post accelerator comprises an RFQ, DTL and SC-linac. The high energy beam lines connect the linear accelerators as well as deliver the accelerated beams to two different experimental areas. The medium energy beam transport (MEBT) line connects the RFQ to the DTL. The high energy beam transport (HEBT) line connects the DTL to the ISAC-I experimental stations (DRAGON, TUDA-I, GPS). The DTL to superconducting beam (DSB) transport line connects the ISAC-I and ISAC-II linacs. The superconducting energy beam transport (SEBT) line connects the SC linac to the ISAC-II experimental station (TUDA-II, HERACLES, TIGRESS, EMMA and GPS). All these lines have the function of transporting and matching the beams to the downstream sections by manipulating the transverse and longitudinal phase space. They also contain diagnostic devices to measure the beam properties.

  1. Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

    SciTech Connect

    Wu, Vincent W.C.; Yang Zhining; Zhang Wuzhe; Wu Lili; Lin Zhixiong

    2012-07-01

    This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

  2. Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma.

    PubMed

    Wu, Vincent W C; Yang, Zhi-Ning; Zhang, Wu-Zhe; Wu, Li-li; Lin, Zhi-xiong

    2012-01-01

    This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

  3. Electron beam focusing system

    SciTech Connect

    Dikansky, N.; Nagaitsev, S.; Parkhomchuk, V.

    1997-09-01

    The high energy electron cooling requires a very cold electron beam. Thus, the electron beam focusing system is very important for the performance of electron cooling. A system with and without longitudinal magnetic field is presented for discussion. Interaction of electron beam with the vacuum chamber as well as with the background ions and stored antiprotons can cause the coherent electron beam instabilities. Focusing system requirements needed to suppress these instabilities are presented.

  4. PARTICLE BEAM TRACKING CIRCUIT

    DOEpatents

    Anderson, O.A.

    1959-05-01

    >A particle-beam tracking and correcting circuit is described. Beam induction electrodes are placed on either side of the beam, and potentials induced by the beam are compared in a voltage comparator or discriminator. This comparison produces an error signal which modifies the fm curve at the voltage applied to the drift tube, thereby returning the orbit to the preferred position. The arrangement serves also to synchronize accelerating frequency and magnetic field growth. (T.R.H.)

  5. Beam Dynamics for ARIA

    SciTech Connect

    Ekdahl, Carl August Jr.

    2014-10-14

    Beam dynamics issues are assessed for a new linear induction electron accelerator being designed for flash radiography of large explosively driven hydrodynamic experiments. Special attention is paid to equilibrium beam transport, possible emittance growth, and beam stability. It is concluded that a radiographic quality beam will be produced possible if engineering standards and construction details are equivalent to those on the present radiography accelerators at Los Alamos.

  6. Feedback about More Accurate versus Less Accurate Trials: Differential Effects on Self-Confidence and Activation

    ERIC Educational Resources Information Center

    Badami, Rokhsareh; VaezMousavi, Mohammad; Wulf, Gabriele; Namazizadeh, Mahdi

    2012-01-01

    One purpose of the present study was to examine whether self-confidence or anxiety would be differentially affected by feedback from more accurate rather than less accurate trials. The second purpose was to determine whether arousal variations (activation) would predict performance. On Day 1, participants performed a golf putting task under one of…

  7. Beam commissioning for a superconducting proton linac

    NASA Astrophysics Data System (ADS)

    Wang, Zhi-Jun; He, Yuan; Jia, Huan; Dou, Wei-ping; Chen, Wei-long; Zhang, X. L.; Liu, Shu-hui; Feng, Chi; Tao, Yue; Wang, Wang-sheng; Wu, Jian-qiang; Zhang, Sheng-hu; Zhao, Hong-Wei

    2016-12-01

    To develop the next generation of safe and cleaner nuclear energy, the accelerator-driven subcritical (ADS) system emerges as one of the most attractive technologies. It will be able to transmute the long-lived transuranic radionuclides produced in the reactors of today's nuclear power plants into shorter-lived ones, and also it will provide positive energy output at the same time. The prototype of the Chinese ADS (C-ADS) proton accelerator comprises two injectors and a 1.5 GeV, 10 mA continuous wave (CW) superconducting main linac. The injector scheme II at the C-ADS demo facility inside the Institute of Modern Physics is a 10 MeV CW superconducting linac with a designed beam current of 10 mA, which includes an ECR ion source, a low-energy beam transport line, a 162.5 MHz radio frequency quadrupole accelerator, a medium-energy beam transport line, and a superconducting half wave resonator accelerator section. This demo facility has been successfully operating with an 11 mA, 2.7 MeV CW beam and a 3.9 mA, 4.3 MeV CW beam at different times and conditions since June 2014. The beam power has reached 28 kW, which is the highest record for the same type of linear accelerators. In this paper, the parameters of the test injector II and the progress of the beam commissioning are reported.

  8. Study of beam-beam effects in eRHIC

    SciTech Connect

    Hao, Y.; Litvinenko, V.; Ptitsyn, V.

    2010-05-23

    Beam-beam effects in eRHIC have a number of unique features, which distinguish them from both hadron and lepton colliders. Due to beam-beam interaction, both electron and hadron beams would suffer quality degradation or beam loss from without proper treatments. Those features need novel study and dedicate countermeasures. We study the beam dynamics and resulting luminosity of the characteristics, including mismatch, disruption and pinch effects on electron beam, in additional to their consequences on the opposing beam as a wake field and other incoherent effects of hadron beam. We also carry out countermeasures to prevent beam quality degrade and coherent instability.

  9. Accurate stochastic reconstruction of heterogeneous microstructures by limited x-ray tomographic projections.

    PubMed

    Li, Hechao; Kaira, Shashank; Mertens, James; Chawla, Nikhilesh; Jiao, Yang

    2016-12-01

    An accurate knowledge of the complex microstructure of a heterogeneous material is crucial for its performance prediction, prognosis and optimization. X-ray tomography has provided a nondestructive means for microstructure characterization in 3D and 4D (i.e. structural evolution over time), in which a material is typically reconstructed from a large number of tomographic projections using filtered-back-projection (FBP) method or algebraic reconstruction techniques (ART). Here, we present in detail a stochastic optimization procedure that enables one to accurately reconstruct material microstructure from a small number of absorption contrast x-ray tomographic projections. This discrete tomography reconstruction procedure is in contrast to the commonly used FBP and ART, which usually requires thousands of projections for accurate microstructure rendition. The utility of our stochastic procedure is first demonstrated by reconstructing a wide class of two-phase heterogeneous materials including sandstone and hard-particle packing from simulated limited-angle projections in both cone-beam and parallel beam projection geometry. It is then applied to reconstruct tailored Sn-sphere-clay-matrix systems from limited-angle cone-beam data obtained via a lab-scale tomography facility at Arizona State University and parallel-beam synchrotron data obtained at Advanced Photon Source, Argonne National Laboratory. In addition, we examine the information content of tomography data by successively incorporating larger number of projections and quantifying the accuracy of the reconstructions. We show that only a small number of projections (e.g. 20-40, depending on the complexity of the microstructure of interest and desired resolution) are necessary for accurate material reconstructions via our stochastic procedure, which indicates its high efficiency in using limited structural information. The ramifications of the stochastic reconstruction procedure in 4D materials science are also

  10. Dual beam optical interferometer

    NASA Technical Reports Server (NTRS)

    Gutierrez, Roman C. (Inventor)

    2003-01-01

    A dual beam interferometer device is disclosed that enables moving an optics module in a direction, which changes the path lengths of two beams of light. The two beams reflect off a surface of an object and generate different speckle patterns detected by an element, such as a camera. The camera detects a characteristic of the surface.

  11. Cooling of Stored Beams

    SciTech Connect

    Mills, F.

    1986-06-10

    Beam cooling methods developed for the accumulation of antiprotons are being employed to assist in the performance of experiments in Nuclear and Particle Physics with ion beams stored in storage rings. The physics of beam cooling, and the ranges of utility of stochastic and electron cooling are discussed in this paper.

  12. Electromagnetic nonuniformly correlated beams.

    PubMed

    Tong, Zhisong; Korotkova, Olga

    2012-10-01

    A class of electromagnetic sources with nonuniformly distributed field correlations is introduced. The conditions on source parameters guaranteeing that the source generates a physical beam are derived. It is shown that the new sources are capable of producing beams with polarization properties that evolve on propagation in a manner much more complex compared to the well-known electromagnetic Gaussian Schell-model beams.

  13. Electron beam device

    DOEpatents

    Beckner, E.H.; Clauser, M.J.

    1975-08-12

    This patent pertains to an electron beam device in which a hollow target is symmetrically irradiated by a high energy, pulsed electron beam about its periphery and wherein the outer portion of the target has a thickness slightly greater than required to absorb the electron beam pulse energy. (auth)

  14. Beam injection into RHIC

    SciTech Connect

    Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

    1997-07-01

    During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

  15. ATA beam director experiment

    SciTech Connect

    Lee, E.P.; Younger, F.C.; Cruz, G.E.; Nolting, E.

    1986-06-23

    This report describes beam director elements for an experiment at the Advanced Test Accelerator. The elements described include a vernier magnet for beam aiming, an achromat magnet, and an isolation system for the beam interface. These components are built at small scale for concept testing. (JDH)

  16. Accurate Guitar Tuning by Cochlear Implant Musicians

    PubMed Central

    Lu, Thomas; Huang, Juan; Zeng, Fan-Gang

    2014-01-01

    Modern cochlear implant (CI) users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task. PMID:24651081

  17. New model accurately predicts reformate composition

    SciTech Connect

    Ancheyta-Juarez, J.; Aguilar-Rodriguez, E. )

    1994-01-31

    Although naphtha reforming is a well-known process, the evolution of catalyst formulation, as well as new trends in gasoline specifications, have led to rapid evolution of the process, including: reactor design, regeneration mode, and operating conditions. Mathematical modeling of the reforming process is an increasingly important tool. It is fundamental to the proper design of new reactors and revamp of existing ones. Modeling can be used to optimize operating conditions, analyze the effects of process variables, and enhance unit performance. Instituto Mexicano del Petroleo has developed a model of the catalytic reforming process that accurately predicts reformate composition at the higher-severity conditions at which new reformers are being designed. The new AA model is more accurate than previous proposals because it takes into account the effects of temperature and pressure on the rate constants of each chemical reaction.

  18. Accurate colorimetric feedback for RGB LED clusters

    NASA Astrophysics Data System (ADS)

    Man, Kwong; Ashdown, Ian

    2006-08-01

    We present an empirical model of LED emission spectra that is applicable to both InGaN and AlInGaP high-flux LEDs, and which accurately predicts their relative spectral power distributions over a wide range of LED junction temperatures. We further demonstrate with laboratory measurements that changes in LED spectral power distribution with temperature can be accurately predicted with first- or second-order equations. This provides the basis for a real-time colorimetric feedback system for RGB LED clusters that can maintain the chromaticity of white light at constant intensity to within +/-0.003 Δuv over a range of 45 degrees Celsius, and to within 0.01 Δuv when dimmed over an intensity range of 10:1.

  19. Accurate guitar tuning by cochlear implant musicians.

    PubMed

    Lu, Thomas; Huang, Juan; Zeng, Fan-Gang

    2014-01-01

    Modern cochlear implant (CI) users understand speech but find difficulty in music appreciation due to poor pitch perception. Still, some deaf musicians continue to perform with their CI. Here we show unexpected results that CI musicians can reliably tune a guitar by CI alone and, under controlled conditions, match simultaneously presented tones to <0.5 Hz. One subject had normal contralateral hearing and produced more accurate tuning with CI than his normal ear. To understand these counterintuitive findings, we presented tones sequentially and found that tuning error was larger at ∼ 30 Hz for both subjects. A third subject, a non-musician CI user with normal contralateral hearing, showed similar trends in performance between CI and normal hearing ears but with less precision. This difference, along with electric analysis, showed that accurate tuning was achieved by listening to beats rather than discriminating pitch, effectively turning a spectral task into a temporal discrimination task.

  20. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures.

    PubMed

    Brahme, Anders; Nyman, Peter; Skatt, Björn

    2008-05-01

    A four-dimensional (4D) laser camera (LC) has been developed for accurate patient imaging in diagnostic and therapeutic radiology. A complementary metal-oxide semiconductor camera images the intersection of a scanned fan shaped laser beam with the surface of the patient and allows real time recording of movements in a three-dimensional (3D) or four-dimensional (4D) format (3D +time). The LC system was first designed as an accurate patient setup tool during diagnostic and therapeutic applications but was found to be of much wider applicability as a general 4D photon "tag" for the surface of the patient in different clinical procedures. It is presently used as a 3D or 4D optical benchmark or tag for accurate delineation of the patient surface as demonstrated for patient auto setup, breathing and heart motion detection. Furthermore, its future potential applications in gating, adaptive therapy, 3D or 4D image fusion between most imaging modalities and image processing are discussed. It is shown that the LC system has a geometrical resolution of about 0, 1 mm and that the rigid body repositioning accuracy is about 0, 5 mm below 20 mm displacements, 1 mm below 40 mm and better than 2 mm at 70 mm. This indicates a slight need for repeated repositioning when the initial error is larger than about 50 mm. The positioning accuracy with standard patient setup procedures for prostate cancer at Karolinska was found to be about 5-6 mm when independently measured using the LC system. The system was found valuable for positron emission tomography-computed tomography (PET-CT) in vivo tumor and dose delivery imaging where it potentially may allow effective correction for breathing artifacts in 4D PET-CT and image fusion with lymph node atlases for accurate target volume definition in oncology. With a LC system in all imaging and radiation therapy rooms, auto setup during repeated diagnostic and therapeutic procedures may save around 5 min per session, increase accuracy and allow

  1. Beam-beam interaction working group summary

    SciTech Connect

    Siemann, R.H.

    1995-03-01

    The limit in hadron colliders is understood phenomenologically. The beam-beam interaction produces nonlinear resonances and makes the transverse tunes amplitude dependent. Tune spreads result from the latter, and as long as these tune spreads do not overlap low order resonances, the lifetime and performance is acceptable. Experience is that tenth and sometimes twelfth order resonances must be avoided, and the hadron collider limit corresponds roughly to the space available between resonances of that and lower order when operating near the coupling resonance. The beam-beam interaction in e{sup +}e{sup {minus}} colliders is not understood well. This affects the performance of existing colliders and could lead to surprises in new ones. For example. a substantial amount of operator tuning is usually required to reach the performance limit given above, and this tuning has to be repeated after each major shutdown. The usual interpretation is that colliding beam performance is sensitive to small lattice errors, and these are being reduced during tuning. It is natural to ask what these errors are, how can a lattice be characterized to minimize tuning time, and what aspects of a lattice should receive particular attention when a new collider is being designed. The answers to this type of question are not known, and developing ideas for calculations, simulations and experiments that could illuminate the details of the beam-beam interaction was the primary working group activity.

  2. An accurate registration technique for distorted images

    NASA Technical Reports Server (NTRS)

    Delapena, Michele; Shaw, Richard A.; Linde, Peter; Dravins, Dainis

    1990-01-01

    Accurate registration of International Ultraviolet Explorer (IUE) images is crucial because the variability of the geometrical distortions that are introduced by the SEC-Vidicon cameras ensures that raw science images are never perfectly aligned with the Intensity Transfer Functions (ITFs) (i.e., graded floodlamp exposures that are used to linearize and normalize the camera response). A technique for precisely registering IUE images which uses a cross correlation of the fixed pattern that exists in all raw IUE images is described.

  3. On accurate determination of contact angle

    NASA Technical Reports Server (NTRS)

    Concus, P.; Finn, R.

    1992-01-01

    Methods are proposed that exploit a microgravity environment to obtain highly accurate measurement of contact angle. These methods, which are based on our earlier mathematical results, do not require detailed measurement of a liquid free-surface, as they incorporate discontinuous or nearly-discontinuous behavior of the liquid bulk in certain container geometries. Physical testing is planned in the forthcoming IML-2 space flight and in related preparatory ground-based experiments.

  4. 13 CFR 123.12 - Are books and records required?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 13 Business Credit and Assistance 1 2011-01-01 2011-01-01 false Are books and records required... PROGRAM Overview § 123.12 Are books and records required? You must retain complete records of all... disaster business or economic injury loan, you must also maintain current and accurate books of...

  5. 13 CFR 123.12 - Are books and records required?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 13 Business Credit and Assistance 1 2013-01-01 2013-01-01 false Are books and records required... PROGRAM Overview § 123.12 Are books and records required? You must retain complete records of all... disaster business or economic injury loan, you must also maintain current and accurate books of...

  6. 13 CFR 123.12 - Are books and records required?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 13 Business Credit and Assistance 1 2012-01-01 2012-01-01 false Are books and records required... PROGRAM Overview § 123.12 Are books and records required? You must retain complete records of all... disaster business or economic injury loan, you must also maintain current and accurate books of...

  7. 13 CFR 123.12 - Are books and records required?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 13 Business Credit and Assistance 1 2014-01-01 2014-01-01 false Are books and records required... PROGRAM Overview § 123.12 Are books and records required? You must retain complete records of all... disaster business or economic injury loan, you must also maintain current and accurate books of...

  8. Accuracy of Step Recording in Free-Living Adults

    ERIC Educational Resources Information Center

    Behrens, Timothy K.; Dinger, Mary K.; Vesely, Sara K.; Fields, David A.

    2007-01-01

    The purpose of this study was to investigate how accurately free-living adults record their pedometer steps on step logs. Researchers used three different methods to examine the accuracy of participant-recorded steps: tests of equivalence, correlation coefficients, and Bland-Altman plots. Findings indicate that participant-recorded steps…

  9. 49 CFR 1220.3 - Preservation of records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a person having personal knowledge of the facts indicating the type of data included within the... if the type of data included in the multiple records is common to all such records. The records shall..., modification, or erasure of the underlying data and will enable production of an accurate and unaltered...

  10. 25 CFR 226.32 - Well records and reports.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... keep accurate and complete records of the drilling, redrilling, deepening, repairing, treating... cement record of casing used in drilling each well; the record of drill-stem and other bottom hole pressure or fluid sample surveys, temperature surveys, directional surveys, and the like; the materials...

  11. 24 CFR 982.158 - Program accounts and records.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Program accounts and records. 982... Contract and PHA Administration of Program § 982.158 Program accounts and records. (a) The PHA must maintain complete and accurate accounts and other records for the program in accordance with...

  12. 10 CFR 221.36 - Records and reports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... from the date of full compliance with such order or directive accurate and complete records of crude... 10 Energy 3 2013-01-01 2013-01-01 false Records and reports. 221.36 Section 221.36 Energy... UNDER THE DEFENSE PRODUCTION ACT Administrative Procedures and Sanctions § 221.36 Records and...

  13. 13 CFR 123.12 - Are books and records required?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Are books and records required... PROGRAM Overview § 123.12 Are books and records required? You must retain complete records of all... disaster business or economic injury loan, you must also maintain current and accurate books of...

  14. Halo formation from mismatched beam-beam interactions

    SciTech Connect

    Qiang, Ji

    2003-05-23

    In this paper, we report on the halo formation and emittance growth driven by a parametric resonance during mismatched beam-beam collisions. In the regime of the weak-strong beam-beam interaction, if two beams have the same machine tunes, on-axis head-on collisions between a mismatched strong beam and a weak beam will not cause the formation of halo. However, if the two beams collide with an initial offset, the beam-beam force from the mismatched strong beam can cause halo formation and emittance growth in the weak beam. Meanwhile, if two beams have different machine tunes, for opposite charged colliding beams, when the machine tune of the weak beam is smaller than that of strong beam, there is emittance growth in the weak beam. When the machine tune of the weak beam is larger than that of the strong beam, there is little emittance growth. In the regime of strong-strong beam-beam interaction, halo is formed in both beams even when the two beams collide head-on on the axis with equal machine tunes. This puts a strong requirement for a good beam match during the injection to colliders in order to avoid the emittance growth.

  15. The oldest accurate record of Scenopinidae in the Lowermost Eocene amber of France (Diptera: Brachycera).

    PubMed

    Garrouste, Romain; Azar, Dany; Nel, Andre

    2016-03-22

    Eocenotrichia magnifica gen. et sp. nov. (Diptera: Scenopinidae: Metatrichini) is described and illustrated from the Lowermost Eocene amber of Oise (France) and represents the oldest definitive window fly fossil. The present discovery in the Earliest Eocene supports the Late Cretaceous-Paleocene age currently proposed for the emergence of Metatrichini.

  16. Large Deformation Dynamic Bending of Composite Beams

    NASA Technical Reports Server (NTRS)

    Derian, E. J.; Hyer, M. W.

    1986-01-01

    Studies were conducted on the large deformation response of composite beams subjected to a dynamic axial load. The beams were loaded with a moderate eccentricity to promote bending. The study was primarily experimental but some finite element results were obtained. Both the deformation and the failure of the beams were of interest. The static response of the beams was also studied to determine potential differences between the static and dynamic failure. Twelve different laminate types were tested. The beams were loaded dynamically with a gravity driven impactor traveling at 19.6 ft/sec and quasi-static tests were conducted on identical beams in a displacement controlled manner. For laminates of practical interest, the failure modes under static and dynamic loadings were identical. Failure in most of the laminate types occurred in a single event involving 40% to 50% of the plies. However, failure in laminates with 30 deg or 15 deg off-axis plies occured in several events. All laminates exhibited bimodular elastic properties. Using empirically determined flexural properties, a finite element analysis was reasonably accurate in predicting the static and dynamic deformation response.

  17. Apparatus and method for laser beam diagnosis

    DOEpatents

    Salmon, Jr., Joseph T.

    1991-01-01

    An apparatus and method is disclosed for accurate, real time monitoring of the wavefront curvature of a coherent laser beam. Knowing the curvature, it can be quickly determined whether the laser beam is collimated, or focusing (converging), or de-focusing (diverging). The apparatus includes a lateral interferometer for forming an interference pattern of the laser beam to be diagnosed. The interference pattern is imaged to a spatial light modulator (SLM), whose output is a coherent laser beam having an image of the interference pattern impressed on it. The SLM output is focused to obtain the far-field diffraction pattern. A video camera, such as CCD, monitors the far-field diffraction pattern, and provides an electrical output indicative of the shape of the far-field pattern. Specifically, the far-field pattern comprises a central lobe and side lobes, whose relative positions are indicative of the radius of curvature of the beam. The video camera's electrical output may be provided to a computer which analyzes the data to determine the wavefront curvature of the laser beam.

  18. Apparatus and method for laser beam diagnosis

    DOEpatents

    Salmon, J.T. Jr.

    1991-08-27

    An apparatus and method are disclosed for accurate, real time monitoring of the wavefront curvature of a coherent laser beam. Knowing the curvature, it can be quickly determined whether the laser beam is collimated, or focusing (converging), or de-focusing (diverging). The apparatus includes a lateral interferometer for forming an interference pattern of the laser beam to be diagnosed. The interference pattern is imaged to a spatial light modulator (SLM), whose output is a coherent laser beam having an image of the interference pattern impressed on it. The SLM output is focused to obtain the far-field diffraction pattern. A video camera, such as CCD, monitors the far-field diffraction pattern, and provides an electrical output indicative of the shape of the far-field pattern. Specifically, the far-field pattern comprises a central lobe and side lobes, whose relative positions are indicative of the radius of curvature of the beam. The video camera's electrical output may be provided to a computer which analyzes the data to determine the wavefront curvature of the laser beam. 11 figures.

  19. High Frequency QRS ECG Accurately Detects Cardiomyopathy

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd T.; Arenare, Brian; Poulin, Gregory; Moser, Daniel R.; Delgado, Reynolds

    2005-01-01

    High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing

  20. Phase rainbow refractometry for accurate droplet variation characterization.

    PubMed

    Wu, Yingchun; Promvongsa, Jantarat; Saengkaew, Sawitree; Wu, Xuecheng; Chen, Jia; Gréhan, Gérard

    2016-10-15

    We developed a one-dimensional phase rainbow refractometer for the accurate trans-dimensional measurements of droplet size on the micrometer scale as well as the tiny droplet diameter variations at the nanoscale. The dependence of the phase shift of the rainbow ripple structures on the droplet variations is revealed. The phase-shifting rainbow image is recorded by a telecentric one-dimensional rainbow imaging system. Experiments on the evaporating monodispersed droplet stream show that the phase rainbow refractometer can measure the tiny droplet diameter changes down to tens of nanometers. This one-dimensional phase rainbow refractometer is capable of measuring the droplet refractive index and diameter, as well as variations.

  1. A fast and accurate FPGA based QRS detection system.

    PubMed

    Shukla, Ashish; Macchiarulo, Luca

    2008-01-01

    An accurate Field Programmable Gate Array (FPGA) based ECG Analysis system is described in this paper. The design, based on a popular software based QRS detection algorithm, calculates the threshold value for the next peak detection cycle, from the median of eight previously detected peaks. The hardware design has accuracy in excess of 96% in detecting the beats correctly when tested with a subset of five 30 minute data records obtained from the MIT-BIH Arrhythmia database. The design, implemented using a proprietary design tool (System Generator), is an extension of our previous work and uses 76% resources available in a small-sized FPGA device (Xilinx Spartan xc3s500), has a higher detection accuracy as compared to our previous design and takes almost half the analysis time in comparison to software based approach.

  2. Accurate superimposition of perimetry data onto fundus photographs.

    PubMed

    Bek, T; Lund-Andersen, H

    1990-02-01

    A technique for accurate superimposition of computerized perimetry data onto the corresponding retinal locations seen on fundus photographs was developed. The technique was designed to take into account: 1) that the photographic field of view of the fundus camera varies with ametropia-dependent camera focusing 2) possible distortion by the fundus camera, and 3) that corrective lenses employed during perimetry magnify or minify the visual field. The technique allowed an overlay of perimetry data of the central 60 degrees of the visual field onto fundus photographs with an accuracy of 0.5 degree. The correlation of localized retinal morphology to localized retinal function was therefore limited by the spatial resolution of the computerized perimetry, which was 2.5 degrees in the Dicon AP-2500 perimeter employed for this study. The theoretical assumptions of the technique were confirmed by comparing visual field records to fundus photographs from patients with morphologically well-defined non-functioning lesions in the retina.

  3. Accurate measurement of the pulse wave delay with imaging photoplethysmography

    PubMed Central

    Kamshilin, Alexei A.; Sidorov, Igor S.; Babayan, Laura; Volynsky, Maxim A.; Giniatullin, Rashid; Mamontov, Oleg V.

    2016-01-01

    Assessment of the cardiovascular parameters using noncontact video-based or imaging photoplethysmography (IPPG) is usually considered as inaccurate because of strong influence of motion artefacts. To optimize this technique we performed a simultaneous recording of electrocardiogram and video frames of the face for 36 healthy volunteers. We found that signal disturbances originate mainly from the stochastically enhanced dichroic notch caused by endogenous cardiovascular mechanisms, with smaller contribution of the motion artefacts. Our properly designed algorithm allowed us to increase accuracy of the pulse-transit-time measurement and visualize propagation of the pulse wave in the facial region. Thus, the accurate measurement of the pulse wave parameters with this technique suggests a sensitive approach to assess local regulation of microcirculation in various physiological and pathological states. PMID:28018731

  4. BEAM CONTROL PROBE

    DOEpatents

    Chesterman, A.W.

    1959-03-17

    A probe is described for intercepting a desired portion of a beam of charged particles and for indicating the spatial disposition of the beam. The disclosed probe assembly includes a pair of pivotally mounted vanes moveable into a single plane with adjacent edges joining and a calibrated mechanical arrangement for pivoting the vancs apart. When the probe is disposed in the path of a charged particle beam, the vanes may be adjusted according to the beam current received in each vane to ascertain the dimension of the beam.

  5. How accurate are Scottish cancer registration data?

    PubMed Central

    Brewster, D.; Crichton, J.; Muir, C.

    1994-01-01

    In order to assess the accuracy of Scottish cancer registration data, a random sample of 2,200 registrations, attributed to the year 1990, was generated. Relevant medical records were available for review in 2,021 (92%) cases. Registration details were reabstracted from available records and compared with data in the registry. Discrepancies in identifying items of data (surname, forename, sex and date of birth) were found in 3.5% of cases. Most were trivial and would not disturb record linkage. Discrepancy rates of 7.1% in post code of residence at the time of diagnosis (excluding differences arising through boundary changes), 11.0% in anniversary date (excluding differences of 6 weeks or less), 7.7% in histological verification status, 5.4% in ICD-9 site codes (the first three digits) and 14.5% in ICD-O morphology codes (excluding 'inferred' morphology codes) were recorded. Overall, serious discrepancies were judged to have occurred in 2.8% of cases. In many respects, therefore, Scottish cancer registration data show a high level of accuracy that compares favourably to the reported accuracy of the few other cancer registries undertaking such analyses. PMID:7947104

  6. Accurate Automated Apnea Analysis in Preterm Infants

    PubMed Central

    Vergales, Brooke D.; Paget-Brown, Alix O.; Lee, Hoshik; Guin, Lauren E.; Smoot, Terri J.; Rusin, Craig G.; Clark, Matthew T.; Delos, John B.; Fairchild, Karen D.; Lake, Douglas E.; Moorman, Randall; Kattwinkel, John

    2017-01-01

    Objective In 2006 the apnea of prematurity (AOP) consensus group identified inaccurate counting of apnea episodes as a major barrier to progress in AOP research. We compare nursing records of AOP to events detected by a clinically validated computer algorithm that detects apnea from standard bedside monitors. Study Design Waveform, vital sign, and alarm data were collected continuously from all very low-birth-weight infants admitted over a 25-month period, analyzed for central apnea, bradycardia, and desaturation (ABD) events, and compared with nursing documentation collected from charts. Our algorithm defined apnea as > 10 seconds if accompanied by bradycardia and desaturation. Results Of the 3,019 nurse-recorded events, only 68% had any algorithm-detected ABD event. Of the 5,275 algorithm-detected prolonged apnea events > 30 seconds, only 26% had nurse-recorded documentation within 1 hour. Monitor alarms sounded in only 74% of events of algorithm-detected prolonged apnea events > 10 seconds. There were 8,190,418 monitor alarms of any description throughout the neonatal intensive care unit during the 747 days analyzed, or one alarm every 2 to 3 minutes per nurse. Conclusion An automated computer algorithm for continuous ABD quantitation is a far more reliable tool than the medical record to address the important research questions identified by the 2006 AOP consensus group. PMID:23592319

  7. Modified algesimeter provides accurate depth measurements

    NASA Technical Reports Server (NTRS)

    Turner, D. P.

    1966-01-01

    Algesimeter which incorporates a standard sensory needle with a sensitive micrometer, measures needle point depth penetration in pain tolerance research. This algesimeter provides an inexpensive, precise instrument with assured validity of recordings in those biomedical areas with a requirement for repeated pain detection or ascertaining pain sensitivity.

  8. Enhanced Photoacoustic Beam Profiling of Pulsed Lasers

    NASA Astrophysics Data System (ADS)

    González, M.; Santiago, G.; Paz, M.; Slezak, V.; Peuriot, A.

    2013-09-01

    An improved version of a photoacoustic beam profiler of pulsed lasers is presented. The new model resorts to high-bandwidth condenser microphones to register higher-order, excited acoustic modes, thus enabling more accurate profiling. In addition, Xe was used as a buffer gas since its high atomic weight further reduces the eigenfrequencies. Furthermore, a new gas-handling system makes up for some deficiencies found in the first model. The system was calibrated using the Airy pattern generated with a pinhole illuminated by a frequency-doubled Nd:YAG laser that excited traces. Once calibrated, the beam profile of a TEA laser was obtained, using ethylene as the absorbing species. This profiler returns more accurate profiles than thermal paper.

  9. ATOMIC BEAM STUDIES IN THE RHIC H-JET POLARIMETER.

    SciTech Connect

    MAKDISI,Y.; ZELENSKI,A.; GRAHAM,D.; KOKHANOVSKI,S.; MAHLER,G.; NASS,A.; RITTER,J.; ZUBETS,V.; ET AL.

    2005-01-28

    The results of atomic beam production studies are presented. Improved cooling of the atoms before jet formation in the dissociator cold nozzle apparently reduces the atomic beam velocity spread and improves beam focusing conditions. A carefully designed sextupole separating (and focusing) magnet system takes advantage of the high brightness source. As a result a record beam intensity of a 12.4 {center_dot} 10{sup 16} atoms/s was obtained within 10 mm acceptance at the collision point. The results of the polarization dilution factor measurements (by the hydrogen molecules at the collision point) are also presented.

  10. Phase Space Generation for Proton and Carbon Ion Beams for External Users’ Applications at the Heidelberg Ion Therapy Center

    PubMed Central

    Tessonnier, Thomas; Marcelos, Tiago; Mairani, Andrea; Brons, Stephan; Parodi, Katia

    2016-01-01

    In the field of radiation therapy, accurate and robust dose calculation is required. For this purpose, precise modeling of the irradiation system and reliable computational platforms are needed. At the Heidelberg Ion Therapy Center (HIT), the beamline has been already modeled in the FLUKA Monte Carlo (MC) code. However, this model was kept confidential for disclosure reasons and was not available for any external team. The main goal of this study was to create efficiently phase space (PS) files for proton and carbon ion beams, for all energies and foci available at HIT. PSs are representing the characteristics of each particle recorded (charge, mass, energy, coordinates, direction cosines, generation) at a certain position along the beam path. In order to achieve this goal, keeping a reasonable data size but maintaining the requested accuracy for the calculation, we developed a new approach of beam PS generation with the MC code FLUKA. The generated PSs were obtained using an infinitely narrow beam and recording the desired quantities after the last element of the beamline, with a discrimination of primaries or secondaries. In this way, a unique PS can be used for each energy to accommodate the different foci by combining the narrow-beam scenario with a random sampling of its theoretical Gaussian beam in vacuum. PS can also reproduce the different patterns from the delivery system, when properly combined with the beam scanning information. MC simulations using PS have been compared to simulations, including the full beamline geometry and have been found in very good agreement for several cases (depth dose distributions, lateral dose profiles), with relative dose differences below 0.5%. This approach has also been compared with measured data of ion beams with different energies and foci, resulting in a very satisfactory agreement. Hence, the proposed approach was able to fulfill the different requirements and has demonstrated its capability for application to

  11. Novel dispersion tolerant interferometry method for accurate measurements of displacement

    NASA Astrophysics Data System (ADS)

    Bradu, Adrian; Maria, Michael; Leick, Lasse; Podoleanu, Adrian G.

    2015-05-01

    We demonstrate that the recently proposed master-slave interferometry method is able to provide true dispersion free depth profiles in a spectrometer-based set-up that can be used for accurate displacement measurements in sensing and optical coherence tomography. The proposed technique is based on correlating the channelled spectra produced by the linear camera in the spectrometer with previously recorded masks. As such technique is not based on Fourier transformations (FT), it does not require any resampling of data and is immune to any amounts of dispersion left unbalanced in the system. In order to prove the tolerance of technique to dispersion, different lengths of optical fiber are used in the interferometer to introduce dispersion and it is demonstrated that neither the sensitivity profile versus optical path difference (OPD) nor the depth resolution are affected. In opposition, it is shown that the classical FT based methods using calibrated data provide less accurate optical path length measurements and exhibit a quicker decays of sensitivity with OPD.

  12. Beam-beam experience in RHIC

    SciTech Connect

    Montag, C.; Heimerle, M.

    2010-07-29

    The Relativistic Heavy Ion Collider RHIC consists of two superconducting storage rings that intersect at six locations around the ring circumference. Two of these interaction regions are currently equipped with experiment detectors, namely STAR at the “6 o’clock” interaction point (IP), and PHENIX at “8 o’clock”. The two beams collide only at these two interaction regions, while they are vertically separated by typically 6-10mm at the other IPs. Together with the separator dipoles located at roughly 10m from the IP, and a distance between bunches of 30m, this avoids any parasitic beam-beam collisions. RHIC is capable of colliding any ion species at magnetic rigidities up to B × r = 830T × m , corresponding to 250 GeV for proton beams, or 100 GeV/n for fully stripped gold ions.

  13. Beam envelope matching for beam guidance systems

    SciTech Connect

    Brown, K.L.

    1980-08-01

    Ray optics and phase ellipse optics are developed as tools for designing charged particle beam guidance systems. Specific examples of basic optical systems and of phase ellipse matching are presented as illustrations of these mathematical techniques.

  14. Refractive beam shapers for focused laser beams

    NASA Astrophysics Data System (ADS)

    Laskin, Alexander; Laskin, Vadim; Ostrun, Aleksei

    2016-09-01

    Focusing of laser radiation is most often used approach in various industrial micromachining applications like scribing, PCB drilling, and is important in scientific researches like laser heating in geophysics experiments with diamond anvil cells (DAC). Control of intensity distribution in focal spot is important task since optimum intensity profiles are rather flat-top, doughnut or "inverse-Gauss" than typical for lasers Gaussian profile. Because of high intensity of modern CW and pulsed lasers it is advisable to use refractive beam shaping optics with smooth optical surfaces providing high radiation resistance. Workable optical solutions can be built on the base of diffraction theory conclusion that flat-top intensity profile in focal plane of a lens is created when input beam has Airy-disk intensity distribution. It is suggested to apply refractive beam shapers converting, with minimum wavefront deformation, Gaussian profile of TEM00 beam to a beam with Airy disk intensity distribution, thereby optimizing conditions of interference near the focal plane of a lens after the beam shaper and providing flat-top, doughnut, "inverse-Gauss" profiles. This approach allows operation with CW and ultra-short pulse lasers, using F-theta lenses and objectives, mirror scanners, provides extended depth of field similar to Rayleigh length of comparable TEM00 beam, easy integration in industrial equipment, simple adjustment procedure and switching between profiles, telescope and collimator implementations. There will be considered design basics of beam shapers, analysis of profile behaviour near focal plane, examples of implementations in micromachining systems and experimental DAC setups, results of profile measurements and material processing.

  15. Integrals for IBS and Beam Cooling

    SciTech Connect

    Burov, A.

    2005-06-08

    Simulation of beam cooling usually requires performing certain integral transformations every time step or so, which is a significant burden on the CPU. Examples are the dispersion integrals (Hilbert transforms) in the stochastic cooling, wake fields and IBS integrals. An original method is suggested for fast and sufficiently accurate computation of the integrals. This method is applied for the dispersion integral. Some methodical aspects of the IBS analysis are discussed.

  16. Cone beam computed tomography use in orthodontics.

    PubMed

    Nervina, J M

    2012-03-01

    Cone beam computed tomography (CBCT) is widely used by orthodontists to obtain three-dimensional (3-D) images of their patients. This is of value as malocclusion results from discrepancies in three planes of space. This review tracks the use of CBCT in orthodontics, from its validation as an accurate and reliable tool, to its use in diagnosing and treatment planning, and in assessing treatment outcomes in orthodontics.

  17. Integrals for IBS and beam cooling

    SciTech Connect

    Burov, A.; /Fermilab

    2005-01-01

    Simulation of beam cooling usually requires performing certain integral transformations every time step or so, which is a significant burden on the CPU. Examples are the dispersion integrals (Hilbert transforms) in the stochastic cooling, wake fields and IBS integrals. An original method is suggested for fast and sufficiently accurate computation of the integrals. This method is applied for the dispersion integral. Some methodical aspects of the IBS analysis are discussed.

  18. Accurate upwind methods for the Euler equations

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1993-01-01

    A new class of piecewise linear methods for the numerical solution of the one-dimensional Euler equations of gas dynamics is presented. These methods are uniformly second-order accurate, and can be considered as extensions of Godunov's scheme. With an appropriate definition of monotonicity preservation for the case of linear convection, it can be shown that they preserve monotonicity. Similar to Van Leer's MUSCL scheme, they consist of two key steps: a reconstruction step followed by an upwind step. For the reconstruction step, a monotonicity constraint that preserves uniform second-order accuracy is introduced. Computational efficiency is enhanced by devising a criterion that detects the 'smooth' part of the data where the constraint is redundant. The concept and coding of the constraint are simplified by the use of the median function. A slope steepening technique, which has no effect at smooth regions and can resolve a contact discontinuity in four cells, is described. As for the upwind step, existing and new methods are applied in a manner slightly different from those in the literature. These methods are derived by approximating the Euler equations via linearization and diagonalization. At a 'smooth' interface, Harten, Lax, and Van Leer's one intermediate state model is employed. A modification for this model that can resolve contact discontinuities is presented. Near a discontinuity, either this modified model or a more accurate one, namely, Roe's flux-difference splitting. is used. The current presentation of Roe's method, via the conceptually simple flux-vector splitting, not only establishes a connection between the two splittings, but also leads to an admissibility correction with no conditional statement, and an efficient approximation to Osher's approximate Riemann solver. These reconstruction and upwind steps result in schemes that are uniformly second-order accurate and economical at smooth regions, and yield high resolution at discontinuities.

  19. Accurate measurement of unsteady state fluid temperature

    NASA Astrophysics Data System (ADS)

    Jaremkiewicz, Magdalena

    2017-03-01

    In this paper, two accurate methods for determining the transient fluid temperature were presented. Measurements were conducted for boiling water since its temperature is known. At the beginning the thermometers are at the ambient temperature and next they are immediately immersed into saturated water. The measurements were carried out with two thermometers of different construction but with the same housing outer diameter equal to 15 mm. One of them is a K-type industrial thermometer widely available commercially. The temperature indicated by the thermometer was corrected considering the thermometers as the first or second order inertia devices. The new design of a thermometer was proposed and also used to measure the temperature of boiling water. Its characteristic feature is a cylinder-shaped housing with the sheath thermocouple located in its center. The temperature of the fluid was determined based on measurements taken in the axis of the solid cylindrical element (housing) using the inverse space marching method. Measurements of the transient temperature of the air flowing through the wind tunnel using the same thermometers were also carried out. The proposed measurement technique provides more accurate results compared with measurements using industrial thermometers in conjunction with simple temperature correction using the inertial thermometer model of the first or second order. By comparing the results, it was demonstrated that the new thermometer allows obtaining the fluid temperature much faster and with higher accuracy in comparison to the industrial thermometer. Accurate measurements of the fast changing fluid temperature are possible due to the low inertia thermometer and fast space marching method applied for solving the inverse heat conduction problem.

  20. Direct design of laser-beam shapers, zoom-beam expanders, and combinations thereof

    NASA Astrophysics Data System (ADS)

    Duerr, Fabian; Thienpont, Hugo

    2016-10-01

    Laser sources have become indispensable for industrial materials processing applications like surface treatment, cutting or welding to name a few examples. Many of these applications pose different requirements on the delivered laser irradiance distribution. Some applications might not only favor a specific irradiance distribution (e.g. a at-top) but can additionally benefit from time-varying distributions. We present an overview of a recently developed design approach that allows direct calculation of virtually any refractive or reflective laser beam shaping system. The derived analytic solution is fully described by few initial parameters and does allow an increasingly accurate calculation of all optical surfaces. Unlike other existing direct design methods for laser beam shaping, there is almost no limitation in the number of surfaces that can be calculated with this approach. This is of particular importance for optical designs of dynamic systems such as variable optical beam expanders that require four (or more) optical surfaces. Besides conventional static beam shapers, we present direct designs of zoom beam expanders, and as a novelty, a class of dynamic systems that shape and expand the input beam simultaneously. Such dynamic zoom beam shapers consist of a minimal number of optical elements and provide a much more compact solution, yet achieving excellent overall optical performance throughout the full range of zoom positions.

  1. Fifty-five years of molecular beams

    SciTech Connect

    Ramsey, N.F.

    1993-05-01

    The history of molecular beams since the invention of molecular beam magnetic resonance is discussed. Rabi`s 1937 theoretical paper on resonance transitions led Rabi, Zacharias, Millman and Kusch to measure various nuclear magnetic moments by magnetic resonance. Kellogg, Rabi, Ramsey and Zacharias found a multiple line radio frequency spectrum in H{sub 2}, D{sub 2}, and HD which enabled them to measure not only the nuclear magnetic moments but also internal molecular interactions including that of the deuteron electric quadrupole moment. The method was successfully extended to atoms. In 1947 Nafe, Nelson and Rabi found that the observed hyperfine separations in atomic hydrogen and deuterium differed from theoretical predictions and Lamb and Retherford soon thereafter observed the large Lamb shift in the atomic fine structures; these two discoveries were the principal incentives for the development of QED, which was confirmed by Kusch`s measurement of the electron magnetic moment. Ramsey`s separated oscillatory field method increased the accuracy and frequency range of the resonance method and provided the basis for accurate atomic clocks. Townes and his associates used a molecular beam for the first Maser as did Goldenberg, Klepper and Ramsey for the atomic hydrogen maser. Many nuclear, atomic and molecular properties have been measured with the molecular beam magnetic resonance. Van der Waal`s molecules and highly excited Rydberg atoms have been examined. Laser spectroscopy has been extensively studied with atomic beams and lasers have been used for state selection and excitation. Wieman and others used atomic beams to study parity and time reversal symmetry. Atomic beams have been slowed by laser cooling and Phillips and others have shown that the atoms can be cooled to about one micro-Kelvin, well below the Doppler limit. Collision experiments between two beams, often from jet sources, provided extensive and detailed information about molecular interactions.

  2. Using an Educational Electronic Documentation System to Help Nursing Students Accurately Identify Nursing Diagnoses

    ERIC Educational Resources Information Center

    Pobocik, Tamara J.

    2013-01-01

    The use of technology and electronic medical records in healthcare has exponentially increased. This quantitative research project used a pretest/posttest design, and reviewed how an educational electronic documentation system helped nursing students to identify the accurate related to statement of the nursing diagnosis for the patient in the case…

  3. The first accurate description of an aurora

    NASA Astrophysics Data System (ADS)

    Schröder, Wilfried

    2006-12-01

    As technology has advanced, the scientific study of auroral phenomena has increased by leaps and bounds. A look back at the earliest descriptions of aurorae offers an interesting look into how medieval scholars viewed the subjects that we study.Although there are earlier fragmentary references in the literature, the first accurate description of the aurora borealis appears to be that published by the German Catholic scholar Konrad von Megenberg (1309-1374) in his book Das Buch der Natur (The Book of Nature). The book was written between 1349 and 1350.

  4. Determining accurate distances to nearby galaxies

    NASA Astrophysics Data System (ADS)

    Bonanos, Alceste Zoe

    2005-11-01

    Determining accurate distances to nearby or distant galaxies is a very simple conceptually, yet complicated in practice, task. Presently, distances to nearby galaxies are only known to an accuracy of 10-15%. The current anchor galaxy of the extragalactic distance scale is the Large Magellanic Cloud, which has large (10-15%) systematic uncertainties associated with it, because of its morphology, its non-uniform reddening and the unknown metallicity dependence of the Cepheid period-luminosity relation. This work aims to determine accurate distances to some nearby galaxies, and subsequently help reduce the error in the extragalactic distance scale and the Hubble constant H 0 . In particular, this work presents the first distance determination of the DIRECT Project to M33 with detached eclipsing binaries. DIRECT aims to obtain a new anchor galaxy for the extragalactic distance scale by measuring direct, accurate (to 5%) distances to two Local Group galaxies, M31 and M33, with detached eclipsing binaries. It involves a massive variability survey of these galaxies and subsequent photometric and spectroscopic follow-up of the detached binaries discovered. In this work, I also present a catalog of variable stars discovered in one of the DIRECT fields, M31Y, which includes 41 eclipsing binaries. Additionally, we derive the distance to the Draco Dwarf Spheroidal galaxy, with ~100 RR Lyrae found in our first CCD variability study of this galaxy. A "hybrid" method of discovering Cepheids with ground-based telescopes is described next. It involves applying the image subtraction technique on the images obtained from ground-based telescopes and then following them up with the Hubble Space Telescope to derive Cepheid period-luminosity distances. By re-analyzing ESO Very Large Telescope data on M83 (NGC 5236), we demonstrate that this method is much more powerful for detecting variability, especially in crowded fields. I finally present photometry for the Wolf-Rayet binary WR 20a

  5. New law requires 'medically accurate' lesson plans.

    PubMed

    1999-09-17

    The California Legislature has passed a bill requiring all textbooks and materials used to teach about AIDS be medically accurate and objective. Statements made within the curriculum must be supported by research conducted in compliance with scientific methods, and published in peer-reviewed journals. Some of the current lesson plans were found to contain scientifically unsupported and biased information. In addition, the bill requires material to be "free of racial, ethnic, or gender biases." The legislation is supported by a wide range of interests, but opposed by the California Right to Life Education Fund, because they believe it discredits abstinence-only material.

  6. ACCURATE KAP METER CALIBRATION AS A PREREQUISITE FOR OPTIMISATION IN PROJECTION RADIOGRAPHY.

    PubMed

    Malusek, A; Sandborg, M; Carlsson, G Alm

    2016-06-01

    Modern X-ray units register the air kerma-area product, PKA, with a built-in KAP meter. Some KAP meters show an energy-dependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to achieve an uncertainty of <7 % as recommended by IAEA. A computational model of the reference KAP meter is used to calculate beam quality correction factors for transfer of the calibration coefficient at the standards laboratory, Q0, to any beam quality, Q, in the clinic. Alternatively, beam quality corrections are measured with an energy-independent dosemeter via a reference beam quality in the clinic, Q1, to beam quality, Q Biases up to 35 % of built-in KAP meter readings were noted. Energy-dependent calibration factors are needed for unbiased PKA Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography.

  7. OPTICAL RECORDING AND COMMUNICATION: Optical recording of transient spatial structures in saturable three-level centres

    NASA Astrophysics Data System (ADS)

    Kucherenko, M. G.; Rusinov, A. P.

    2004-08-01

    Optical recording and decay of transient spatial structures is analysed in a system with a nonlinear response caused by incoherent saturation of three-level centres. The main attention is devoted to the thermal mechanism of phase recording in media with the temperature-independent heat conductivity. The relaxation of an inhomogeneous temperature field and the diffraction of a probe beam from the transient structure are studied.

  8. VIZIR: The SEP high resolution laser beam recorder

    NASA Technical Reports Server (NTRS)

    Salter, M. L.; Maincent, M. G.

    1977-01-01

    A means for high density archiving of meteorological data on a photographic film is described. The data are stored on-line under a form accessible to interpretation. The VIZIR thus forms the final link of the receiving system of a ground station.

  9. Bolt beam propagation analysis

    NASA Astrophysics Data System (ADS)

    Shokair, I. R.

    BOLT (Beam on Laser Technology) is a rocket experiment to demonstrate electron beam propagation on a laser ionized plasma channel across the geomagnetic field in the ion focused regime (IFR). The beam parameters for BOLT are: beam current I(sub b) = 100 Amps, beam energy of 1--1.5 MeV (gamma =3-4), and a Gaussian beam and channel of radii r(sub b) = r(sub c) = 1.5 cm. The N+1 ionization scheme is used to ionize atomic oxygen in the upper atmosphere. This scheme utilizes 130 nm light plus three IR lasers to excite and then ionize atomic oxygen. The limiting factor for the channel strength is the energy of the 130 nm laser, which is assumed to be 1.6 mJ for BOLT. At a fixed laser energy and altitude (fixing the density of atomic oxygen), the range can be varied by adjusting the laser tuning, resulting in a neutralization fraction axial profile of the form: f(z) = f(sub 0) e(exp minus z)/R, where R is the range. In this paper we consider the propagation of the BOLT beam and calculate the range of the electron beam taking into account the fact that the erosion rates (magnetic and inductive) vary with beam length as the beam and channel dynamically respond to sausage and hose instabilities.

  10. Accurate taxonomic assignment of short pyrosequencing reads.

    PubMed

    Clemente, José C; Jansson, Jesper; Valiente, Gabriel

    2010-01-01

    Ambiguities in the taxonomy dependent assignment of pyrosequencing reads are usually resolved by mapping each read to the lowest common ancestor in a reference taxonomy of all those sequences that match the read. This conservative approach has the drawback of mapping a read to a possibly large clade that may also contain many sequences not matching the read. A more accurate taxonomic assignment of short reads can be made by mapping each read to the node in the reference taxonomy that provides the best precision and recall. We show that given a suffix array for the sequences in the reference taxonomy, a short read can be mapped to the node of the reference taxonomy with the best combined value of precision and recall in time linear in the size of the taxonomy subtree rooted at the lowest common ancestor of the matching sequences. An accurate taxonomic assignment of short reads can thus be made with about the same efficiency as when mapping each read to the lowest common ancestor of all matching sequences in a reference taxonomy. We demonstrate the effectiveness of our approach on several metagenomic datasets of marine and gut microbiota.

  11. Accurate shear measurement with faint sources

    SciTech Connect

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao E-mail: walt@shao.ac.cn

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys.

  12. Accurate pose estimation for forensic identification

    NASA Astrophysics Data System (ADS)

    Merckx, Gert; Hermans, Jeroen; Vandermeulen, Dirk

    2010-04-01

    In forensic authentication, one aims to identify the perpetrator among a series of suspects or distractors. A fundamental problem in any recognition system that aims for identification of subjects in a natural scene is the lack of constrains on viewing and imaging conditions. In forensic applications, identification proves even more challenging, since most surveillance footage is of abysmal quality. In this context, robust methods for pose estimation are paramount. In this paper we will therefore present a new pose estimation strategy for very low quality footage. Our approach uses 3D-2D registration of a textured 3D face model with the surveillance image to obtain accurate far field pose alignment. Starting from an inaccurate initial estimate, the technique uses novel similarity measures based on the monogenic signal to guide a pose optimization process. We will illustrate the descriptive strength of the introduced similarity measures by using them directly as a recognition metric. Through validation, using both real and synthetic surveillance footage, our pose estimation method is shown to be accurate, and robust to lighting changes and image degradation.

  13. Sparse and accurate high resolution SAR imaging

    NASA Astrophysics Data System (ADS)

    Vu, Duc; Zhao, Kexin; Rowe, William; Li, Jian

    2012-05-01

    We investigate the usage of an adaptive method, the Iterative Adaptive Approach (IAA), in combination with a maximum a posteriori (MAP) estimate to reconstruct high resolution SAR images that are both sparse and accurate. IAA is a nonparametric weighted least squares algorithm that is robust and user parameter-free. IAA has been shown to reconstruct SAR images with excellent side lobes suppression and high resolution enhancement. We first reconstruct the SAR images using IAA, and then we enforce sparsity by using MAP with a sparsity inducing prior. By coupling these two methods, we can produce a sparse and accurate high resolution image that are conducive for feature extractions and target classification applications. In addition, we show how IAA can be made computationally efficient without sacrificing accuracies, a desirable property for SAR applications where the size of the problems is quite large. We demonstrate the success of our approach using the Air Force Research Lab's "Gotcha Volumetric SAR Data Set Version 1.0" challenge dataset. Via the widely used FFT, individual vehicles contained in the scene are barely recognizable due to the poor resolution and high side lobe nature of FFT. However with our approach clear edges, boundaries, and textures of the vehicles are obtained.

  14. Accurate basis set truncation for wavefunction embedding

    NASA Astrophysics Data System (ADS)

    Barnes, Taylor A.; Goodpaster, Jason D.; Manby, Frederick R.; Miller, Thomas F.

    2013-07-01

    Density functional theory (DFT) provides a formally exact framework for performing embedded subsystem electronic structure calculations, including DFT-in-DFT and wavefunction theory-in-DFT descriptions. In the interest of efficiency, it is desirable to truncate the atomic orbital basis set in which the subsystem calculation is performed, thus avoiding high-order scaling with respect to the size of the MO virtual space. In this study, we extend a recently introduced projection-based embedding method [F. R. Manby, M. Stella, J. D. Goodpaster, and T. F. Miller III, J. Chem. Theory Comput. 8, 2564 (2012)], 10.1021/ct300544e to allow for the systematic and accurate truncation of the embedded subsystem basis set. The approach is applied to both covalently and non-covalently bound test cases, including water clusters and polypeptide chains, and it is demonstrated that errors associated with basis set truncation are controllable to well within chemical accuracy. Furthermore, we show that this approach allows for switching between accurate projection-based embedding and DFT embedding with approximate kinetic energy (KE) functionals; in this sense, the approach provides a means of systematically improving upon the use of approximate KE functionals in DFT embedding.

  15. Study of multiple hologram recording in lithium niobate

    NASA Technical Reports Server (NTRS)

    Gaylord, T. K.; Callen, W. R.

    1974-01-01

    The results of detailed experimental and theoretical considerations relating to multiple hologram recording in lithium niobate are reported. The following problem areas are identified and discussed: (1) the angular selectivity of the stored holograms, (2) interference effects due to the crystal surfaces, (3) beam divergence effects, (4) material recording sensitivity, and (5) scattered light from material inhomogeneities.

  16. Laser image recording on detonation nanodiamond films

    NASA Astrophysics Data System (ADS)

    Mikheev, G. M.; Mikheev, K. G.; Mogileva, T. N.; Puzyr, A. P.; Bondar, V. S.

    2014-01-01

    A focused He - Ne laser beam is shown to cause local blackening of semitransparent detonation nanodiamond (DND) films at incident power densities above 600 W cm-2. Data obtained with a Raman spectrometer and low-power 632.8-nm laser source indicate that the blackening is accompanied by a decrease in broadband background luminescence and emergence of sharp Raman peaks corresponding to the structures of nanodiamond and sp2 carbon. The feasibility of image recording on DND films by a focused He - Ne laser beam is demonstrated.

  17. [City and County Records.

    ERIC Educational Resources Information Center

    Combs, Judith O.; And Others

    Six papers presented at the Institute were concerned with city and county records. They are: "EWEB and Its Records," which discusses the history, laws and records of the Eugene Water and Electric Board (EWEB);""Police Records: Eugene, Oregon," classifies police records, other than administrative, into three general…

  18. Craft Stick Beams

    NASA Technical Reports Server (NTRS)

    Karplus, Alan K.

    1996-01-01

    The objective of this exercise is to provide a phenomenological 'hands-on' experience that shows how geometry can affect the load carrying capacity of a material used in construction, how different materials have different failure characteristics, and how construction affects the performance of a composite material. This will be accomplished by building beams of a single material and composite beams of a mixture of materials (popsicle sticks, fiberboard sheets, and tongue depressors); testing these layered beams to determine how and where they fail; and based on the failure analysis, designing a layered beam that will fail in a predicted manner. The students will learn the effects of lamination, adhesion, and geometry in layered beam construction on beam strength and failure location.

  19. Particle beam injection system

    DOEpatents

    Jassby, Daniel L.; Kulsrud, Russell M.

    1977-01-01

    This invention provides a poloidal divertor for stacking counterstreaming ion beams to provide high intensity colliding beams. To this end, method and apparatus are provided that inject high energy, high velocity, ordered, atomic deuterium and tritium beams into a lower energy, toroidal, thermal equilibrium, neutral, target plasma column that is magnetically confined along an endless magnetic axis in a strong restoring force magnetic field having helical field lines to produce counterstreaming deuteron and triton beams that are received bent, stacked and transported along the endless axis, while a poloidal divertor removes thermal ions and electrons all along the axis to increase the density of the counterstreaming ion beams and the reaction products resulting therefrom. By balancing the stacking and removal, colliding, strong focused particle beams, reaction products and reactions are produced that convert one form of energy into another form of energy.

  20. Focused Bessel beams

    SciTech Connect

    Adamson, P V

    2000-04-30

    The diffraction broadening of a focused beam with a Bessel amplitude distribution is examined. Calculations are reported not only of the traditional differential characteristics (radial distributions of the electric-energy densities and of the axial total electromagnetic energy flux in the beam), but also of integral quantities characterising the degree of transverse localisation of the radiation in a tube of specified radius within the beam. It is shown that in a large-aperture Bessel beam only a very small fraction of the total beam power is concentrated in its central core and that a focal point is also observed on intense focusing of the Bessel beam. This spot is not in the geometric-optical focal plane but is displaced from the latter by a certain distance. (laser applications and other topics in quantum electronics)

  1. A Nonlinear Finite Element Framework for Viscoelastic Beams Based on the High-Order Reddy Beam Theory

    DTIC Science & Technology

    2012-06-09

    employed theories are the Euler-Bernoulli beam theory (EBT) and the Timoshenko beam theory ( TBT ). The major deficiency associated with the EBT is failure to...account for defor- mations associated with shearing. The TBT relaxes the normality assumption of the EBT and admits a constant state of shear strain...on a given cross-section. As a result, the TBT necessitates the use of shear correction coefficients in order to accurately predict transverse

  2. Electromagnetic ion beam instabilities

    NASA Technical Reports Server (NTRS)

    Gary, S. P.; Foosland, D. W.; Smith, C. W.; Lee, M. A.; Goldstein, M. L.

    1984-01-01

    The linear theory of electromagnetic instabilities driven by an energetic ion beam streaming parallel to a magnetic field in a homogeneous Vlasov plasma is considered. Numerical solutions of the full dispersion equation are presented. At propagation parallel to the magnetic field, there are four distinct instabilities. A sufficiently energetic beam gives rise to two unstable modes with right-hand polarization, one resonant with the beam, the other nonresonant. A beam with sufficiently large T (perpendicular to B)/T (parallel to B) gives rise to the left-hand ion cyclotron anisotropy instability at relatively small beam velocities, and a sufficiently hot beam drives unstable a left-hand beam resonant mode. The parametric dependences of the growth rates for the three high beam velocity instabilities are presented here. In addition, some properties at oblique propagation are examined. It is demonstrated that, as the beam drift velocity is increased, relative maxima in growth rates can arise at harmonics of the ion cyclotron resonance for both right and left elliptically polarized modes.

  3. Pulsed ion beam source

    DOEpatents

    Greenly, John B.

    1996-01-01

    An improved magnetically-confined anode plasma pulsed ion beam source. Beam rotation effects and power efficiency are improved by a magnetic design which places the separatrix between the fast field flux structure and the slow field structure near the anode of the ion beam source, by a gas port design which localizes the gas delivery into the gap between the fast coil and the anode, by a pre-ionizer ringing circuit connected to the fast coil, and by a bias field means which optimally adjusts the plasma formation position in the ion beam source.

  4. Power beaming options

    NASA Technical Reports Server (NTRS)

    Rather, John D. G.

    1989-01-01

    Some large scale power beaming applications are proposed for the purpose of stimulating research. The first proposal is for a combination of large phased arrays on the ground near power stations and passive reflectors in geostationary orbit. The systems would beam excess electrical power in microwave form to areas in need of electrical power. Another proposal is to build solar arrays in deserts and beam the energy around the world. Another proposal is to use lasers to beam energy from earth to orbiting spacecraft.

  5. Plasma Beam Measurements

    DTIC Science & Technology

    1991-08-01

    GUN PLASMA BEAM / ,I 21 cm diameter = 0 GLASS DRIFT TUBE 50 cm diameter MCP CAMERA CLASS CROSSES (a) Gun muzzle /"- PLASA BEAM / TAROT z = 10 m MCP...discusses some of the hydrodynamic issues related to the calcula- tions. The reader may well wonder why hydrodynamics should be an issue in a 116 WL-TR-90...answer is yes for the slow beam cases and no for the fast beam cases. This is explained further. 118 WL-TR-90-83 The reader will recall the

  6. Broad beam ion implanter

    DOEpatents

    Leung, K.N.

    1996-10-08

    An ion implantation device for creating a large diameter, homogeneous, ion beam is described, as well as a method for creating same, wherein the device is characterized by extraction of a diverging ion beam and its conversion by ion beam optics to an essentially parallel ion beam. The device comprises a plasma or ion source, an anode and exit aperture, an extraction electrode, a divergence-limiting electrode and an acceleration electrode, as well as the means for connecting a voltage supply to the electrodes. 6 figs.

  7. Broad beam ion implanter

    DOEpatents

    Leung, Ka-Ngo

    1996-01-01

    An ion implantation device for creating a large diameter, homogeneous, ion beam is described, as well as a method for creating same, wherein the device is characterized by extraction of a diverging ion beam and its conversion by ion beam optics to an essentially parallel ion beam. The device comprises a plasma or ion source, an anode and exit aperture, an extraction electrode, a divergence-limiting electrode and an acceleration electrode, as well as the means for connecting a voltage supply to the electrodes.

  8. Magnetic beam position monitor

    SciTech Connect

    Varfolomeev, A.A.; Ivanchenkov, S.N.; Khlebnikov, A.S.

    1995-12-31

    Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for the conditions adequate to the FOM-FEM project.

  9. (Pulsed electron beam precharger)

    SciTech Connect

    Finney, W.C.; Shelton, W.N.

    1990-01-01

    This report discusses the following topics on electron beam guns: Precharger Modification; Installation of Charge vs. Radius Apparatus; High Concentration Aerosol Generation; and Data Acquisition and Analysis System.

  10. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  11. Apparatus for accurately measuring high temperatures

    DOEpatents

    Smith, Douglas D.

    1985-01-01

    The present invention is a thermometer used for measuring furnace temperaes in the range of about 1800.degree. to 2700.degree. C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  12. LSM: perceptually accurate line segment merging

    NASA Astrophysics Data System (ADS)

    Hamid, Naila; Khan, Nazar

    2016-11-01

    Existing line segment detectors tend to break up perceptually distinct line segments into multiple segments. We propose an algorithm for merging such broken segments to recover the original perceptually accurate line segments. The algorithm proceeds by grouping line segments on the basis of angular and spatial proximity. Then those line segment pairs within each group that satisfy unique, adaptive mergeability criteria are successively merged to form a single line segment. This process is repeated until no more line segments can be merged. We also propose a method for quantitative comparison of line segment detection algorithms. Results on the York Urban dataset show that our merged line segments are closer to human-marked ground-truth line segments compared to state-of-the-art line segment detection algorithms.

  13. Highly accurate articulated coordinate measuring machine

    DOEpatents

    Bieg, Lothar F.; Jokiel, Jr., Bernhard; Ensz, Mark T.; Watson, Robert D.

    2003-12-30

    Disclosed is a highly accurate articulated coordinate measuring machine, comprising a revolute joint, comprising a circular encoder wheel, having an axis of rotation; a plurality of marks disposed around at least a portion of the circumference of the encoder wheel; bearing means for supporting the encoder wheel, while permitting free rotation of the encoder wheel about the wheel's axis of rotation; and a sensor, rigidly attached to the bearing means, for detecting the motion of at least some of the marks as the encoder wheel rotates; a probe arm, having a proximal end rigidly attached to the encoder wheel, and having a distal end with a probe tip attached thereto; and coordinate processing means, operatively connected to the sensor, for converting the output of the sensor into a set of cylindrical coordinates representing the position of the probe tip relative to a reference cylindrical coordinate system.

  14. Practical aspects of spatially high accurate methods

    NASA Technical Reports Server (NTRS)

    Godfrey, Andrew G.; Mitchell, Curtis R.; Walters, Robert W.

    1992-01-01

    The computational qualities of high order spatially accurate methods for the finite volume solution of the Euler equations are presented. Two dimensional essentially non-oscillatory (ENO), k-exact, and 'dimension by dimension' ENO reconstruction operators are discussed and compared in terms of reconstruction and solution accuracy, computational cost and oscillatory behavior in supersonic flows with shocks. Inherent steady state convergence difficulties are demonstrated for adaptive stencil algorithms. An exact solution to the heat equation is used to determine reconstruction error, and the computational intensity is reflected in operation counts. Standard MUSCL differencing is included for comparison. Numerical experiments presented include the Ringleb flow for numerical accuracy and a shock reflection problem. A vortex-shock interaction demonstrates the ability of the ENO scheme to excel in simulating unsteady high-frequency flow physics.

  15. Toward Accurate and Quantitative Comparative Metagenomics

    PubMed Central

    Nayfach, Stephen; Pollard, Katherine S.

    2016-01-01

    Shotgun metagenomics and computational analysis are used to compare the taxonomic and functional profiles of microbial communities. Leveraging this approach to understand roles of microbes in human biology and other environments requires quantitative data summaries whose values are comparable across samples and studies. Comparability is currently hampered by the use of abundance statistics that do not estimate a meaningful parameter of the microbial community and biases introduced by experimental protocols and data-cleaning approaches. Addressing these challenges, along with improving study design, data access, metadata standardization, and analysis tools, will enable accurate comparative metagenomics. We envision a future in which microbiome studies are replicable and new metagenomes are easily and rapidly integrated with existing data. Only then can the potential of metagenomics for predictive ecological modeling, well-powered association studies, and effective microbiome medicine be fully realized. PMID:27565341

  16. Obtaining accurate translations from expressed sequence tags.

    PubMed

    Wasmuth, James; Blaxter, Mark

    2009-01-01

    The genomes of an increasing number of species are being investigated through the generation of expressed sequence tags (ESTs). However, ESTs are prone to sequencing errors and typically define incomplete transcripts, making downstream annotation difficult. Annotation would be greatly improved with robust polypeptide translations. Many current solutions for EST translation require a large number of full-length gene sequences for training purposes, a resource that is not available for the majority of EST projects. As part of our ongoing EST programs investigating these "neglected" genomes, we have developed a polypeptide prediction pipeline, prot4EST. It incorporates freely available software to produce final translations that are more accurate than those derived from any single method. We describe how this integrated approach goes a long way to overcoming the deficit in training data.

  17. Micron Accurate Absolute Ranging System: Range Extension

    NASA Technical Reports Server (NTRS)

    Smalley, Larry L.; Smith, Kely L.

    1999-01-01

    The purpose of this research is to investigate Fresnel diffraction as a means of obtaining absolute distance measurements with micron or greater accuracy. It is believed that such a system would prove useful to the Next Generation Space Telescope (NGST) as a non-intrusive, non-contact measuring system for use with secondary concentrator station-keeping systems. The present research attempts to validate past experiments and develop ways to apply the phenomena of Fresnel diffraction to micron accurate measurement. This report discusses past research on the phenomena, and the basis of the use Fresnel diffraction distance metrology. The apparatus used in the recent investigations, experimental procedures used, preliminary results are discussed in detail. Continued research and equipment requirements on the extension of the effective range of the Fresnel diffraction systems is also described.

  18. Accurate radio positions with the Tidbinbilla interferometer

    NASA Technical Reports Server (NTRS)

    Batty, M. J.; Gulkis, S.; Jauncey, D. L.; Rayner, P. T.

    1979-01-01

    The Tidbinbilla interferometer (Batty et al., 1977) is designed specifically to provide accurate radio position measurements of compact radio sources in the Southern Hemisphere with high sensitivity. The interferometer uses the 26-m and 64-m antennas of the Deep Space Network at Tidbinbilla, near Canberra. The two antennas are separated by 200 m on a north-south baseline. By utilizing the existing antennas and the low-noise traveling-wave masers at 2.29 GHz, it has been possible to produce a high-sensitivity instrument with a minimum of capital expenditure. The north-south baseline ensures that a good range of UV coverage is obtained, so that sources lying in the declination range between about -80 and +30 deg may be observed with nearly orthogonal projected baselines of no less than about 1000 lambda. The instrument also provides high-accuracy flux density measurements for compact radio sources.

  19. Magnetic ranging tool accurately guides replacement well

    SciTech Connect

    Lane, J.B.; Wesson, J.P. )

    1992-12-21

    This paper reports on magnetic ranging surveys and directional drilling technology which accurately guided a replacement well bore to intersect a leaking gas storage well with casing damage. The second well bore was then used to pump cement into the original leaking casing shoe. The repair well bore kicked off from the surface hole, bypassed casing damage in the middle of the well, and intersected the damaged well near the casing shoe. The repair well was subsequently completed in the gas storage zone near the original well bore, salvaging the valuable bottom hole location in the reservoir. This method would prevent the loss of storage gas, and it would prevent a potential underground blowout that could permanently damage the integrity of the storage field.

  20. More on analyzing the reflection of a laser beam by a deformed highly reflective volume Bragg grating using iteration of the beam propagation method.

    PubMed

    Shu, Hong; Mokhov, Sergiy; Zeldovich, Boris Ya; Bass, Michael

    2009-01-01

    A further extension of the iteration method for beam propagation calculation is presented that can be applied for volume Bragg gratings (VBGs) with extremely large grating strength. A reformulation of the beam propagation formulation is presented for analyzing the reflection of a laser beam by a deformed VBG. These methods will be shown to be very accurate and efficient. A VBG with generic z-dependent distortion has been analyzed using these methods.

  1. The high cost of accurate knowledge.

    PubMed

    Sutcliffe, Kathleen M; Weber, Klaus

    2003-05-01

    Many business thinkers believe it's the role of senior managers to scan the external environment to monitor contingencies and constraints, and to use that precise knowledge to modify the company's strategy and design. As these thinkers see it, managers need accurate and abundant information to carry out that role. According to that logic, it makes sense to invest heavily in systems for collecting and organizing competitive information. Another school of pundits contends that, since today's complex information often isn't precise anyway, it's not worth going overboard with such investments. In other words, it's not the accuracy and abundance of information that should matter most to top executives--rather, it's how that information is interpreted. After all, the role of senior managers isn't just to make decisions; it's to set direction and motivate others in the face of ambiguities and conflicting demands. Top executives must interpret information and communicate those interpretations--they must manage meaning more than they must manage information. So which of these competing views is the right one? Research conducted by academics Sutcliffe and Weber found that how accurate senior executives are about their competitive environments is indeed less important for strategy and corresponding organizational changes than the way in which they interpret information about their environments. Investments in shaping those interpretations, therefore, may create a more durable competitive advantage than investments in obtaining and organizing more information. And what kinds of interpretations are most closely linked with high performance? Their research suggests that high performers respond positively to opportunities, yet they aren't overconfident in their abilities to take advantage of those opportunities.

  2. Your Medical Records

    MedlinePlus

    ... sometimes, but many health care providers now keep electronic records. You might hear medical people call these EHRs — short for electronic health records . Electronic records make it easier for ...

  3. 42 CFR 73.17 - Records.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... AND TOXINS § 73.17 Records. (a) An individual or entity required to register under this part must... appropriate disposition); (3) Accurate, current inventory for each toxin held, including: (i) The name and..., milliliters, grams, etc.), (iv) The toxin used and purpose of use, quantity, date(s) of the use and by...

  4. 42 CFR 73.17 - Records.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... AND TOXINS § 73.17 Records. (a) An individual or entity required to register under this part must... appropriate disposition); (3) Accurate, current inventory for each toxin held, including: (i) The name and..., milliliters, grams, etc.), (iv) The toxin used and purpose of use, quantity, date(s) of the use and by...

  5. Approaching system equilibrium with accurate or not accurate feedback information in a two-route system

    NASA Astrophysics Data System (ADS)

    Zhao, Xiao-mei; Xie, Dong-fan; Li, Qi

    2015-02-01

    With the development of intelligent transport system, advanced information feedback strategies have been developed to reduce traffic congestion and enhance the capacity. However, previous strategies provide accurate information to travelers and our simulation results show that accurate information brings negative effects, especially in delay case. Because travelers prefer to the best condition route with accurate information, and delayed information cannot reflect current traffic condition but past. Then travelers make wrong routing decisions, causing the decrease of the capacity and the increase of oscillations and the system deviating from the equilibrium. To avoid the negative effect, bounded rationality is taken into account by introducing a boundedly rational threshold BR. When difference between two routes is less than the BR, routes have equal probability to be chosen. The bounded rationality is helpful to improve the efficiency in terms of capacity, oscillation and the gap deviating from the system equilibrium.

  6. Keeping the Records Straight.

    ERIC Educational Resources Information Center

    Clift, Phil; Keynes, Milton

    1982-01-01

    Guidelines are given regarding keeping and using educational records for exceptional children in Great Britain. Procedures related to anecdotal records, observation inventories, and rating scales are delineated. (CL)

  7. Recording and Scanning Advances in Cartographic EBR Systems.

    DTIC Science & Technology

    1981-06-01

    34Cartographic Electron Beam Recording," 2nd Annual William T. Pecora Memorial Symposium on Mapping and Remote Sensing Data, Sponsored ASP, USGS, NASA...using the experimental Cartographic EBR System. These were: (a) GAF Electrostatic Film - toner processed (b) GAF Direct Recording Materials - no...processing required (c) Kodak Direct Recording ESR-l - no processing required (d) GAF Electrostatic Films - color toner processed (e) Kodak S0214

  8. 7 CFR 82.13 - Records and accounts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) EXPORT AND DOMESTIC CONSUMPTION... this program must keep accurate records and accounts showing the details relative to the...

  9. 21 CFR 312.62 - Investigator recordkeeping and record retention.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... investigator is required to prepare and maintain adequate and accurate case histories that record all... under this part for a period of 2 years following the date a marketing application is approved for...

  10. Improved antenna pattern recorder provides visual display of RF power

    NASA Technical Reports Server (NTRS)

    Lipin, R., Jr.

    1970-01-01

    Antenna pattern recording system has a discretionary signal level monitor which senses a specified minimum level occurring between sampling intervals. This enables RF power and percent coverage to be calculated more accurately.

  11. Higher order accurate partial implicitization: An unconditionally stable fourth-order-accurate explicit numerical technique

    NASA Technical Reports Server (NTRS)

    Graves, R. A., Jr.

    1975-01-01

    The previously obtained second-order-accurate partial implicitization numerical technique used in the solution of fluid dynamic problems was modified with little complication to achieve fourth-order accuracy. The Von Neumann stability analysis demonstrated the unconditional linear stability of the technique. The order of the truncation error was deduced from the Taylor series expansions of the linearized difference equations and was verified by numerical solutions to Burger's equation. For comparison, results were also obtained for Burger's equation using a second-order-accurate partial-implicitization scheme, as well as the fourth-order scheme of Kreiss.

  12. A new beamstop for microfocus X-ray capillary beams

    PubMed Central

    Englich, Ulrich; Revesz, Peter; Miller, William

    2011-01-01

    In order to accurately measure the photon flux and to assist in aligning the beam, we have designed a modified beam stop device based on a photo diode integrated with the beam stop. The beam stop contains a small CdWO4 crystal that completely stops the X-rays and at the same time produces photoluminescence proportional to the X-ray flux. The light is then guided to a photosensitive diode, using a flexible light pipe, to monitor the flux. With this device we achieve the goal of stopping the primary X-ray beam and simultaneously monitoring the X-ray intensity, thus eliminating the need for integrating ion-chambers into the capillary or collimator mount. PMID:21822345

  13. Phoenix's Laser Beam in Action on Mars

    NASA Technical Reports Server (NTRS)

    2008-01-01

    [figure removed for brevity, see original site] Click on image to view the animation

    The Surface Stereo Imager camera aboard NASA's Phoenix Mars Lander acquired a series of images of the laser beam in the Martian night sky. Bright spots in the beam are reflections from ice crystals in the low level ice-fog. The brighter area at the top of the beam is due to enhanced scattering of the laser light in a cloud. The Canadian-built lidar instrument emits pulses of laser light and records what is scattered back.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  14. Fast and accurate computation of system matrix for area integral model-based algebraic reconstruction technique

    NASA Astrophysics Data System (ADS)

    Zhang, Shunli; Zhang, Dinghua; Gong, Hao; Ghasemalizadeh, Omid; Wang, Ge; Cao, Guohua

    2014-11-01

    Iterative algorithms, such as the algebraic reconstruction technique (ART), are popular for image reconstruction. For iterative reconstruction, the area integral model (AIM) is more accurate for better reconstruction quality than the line integral model (LIM). However, the computation of the system matrix for AIM is more complex and time-consuming than that for LIM. Here, we propose a fast and accurate method to compute the system matrix for AIM. First, we calculate the intersection of each boundary line of a narrow fan-beam with pixels in a recursive and efficient manner. Then, by grouping the beam-pixel intersection area into six types according to the slopes of the two boundary lines, we analytically compute the intersection area of the narrow fan-beam with the pixels in a simple algebraic fashion. Overall, experimental results show that our method is about three times faster than the Siddon algorithm and about two times faster than the distance-driven model (DDM) in computation of the system matrix. The reconstruction speed of our AIM-based ART is also faster than the LIM-based ART that uses the Siddon algorithm and DDM-based ART, for one iteration. The fast reconstruction speed of our method was accomplished without compromising the image quality.

  15. Recording multiple spatially-heterodyned direct to digital holograms in one digital image

    DOEpatents

    Hanson, Gregory R.; Bingham, Philip R.

    2008-03-25

    Systems and methods are described for recording multiple spatially-heterodyned direct to digital holograms in one digital image. A method includes digitally recording, at a first reference beam-object beam angle, a first spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; Fourier analyzing the recorded first spatially-heterodyned hologram by shifting a first original origin of the recorded first spatially-heterodyned hologram to sit on top of a first spatial-heterodyne carrier frequency defined by the first reference beam-object beam angle; digitally recording, at a second reference beam-object beam angle, a second spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; Fourier analyzing the recorded second spatially-heterodyned hologram by shifting a second original origin of the recorded second spatially-heterodyned hologram to sit on top of a second spatial-heterodyne carrier frequency defined by the second reference beam-object beam angle; applying a first digital filter to cut off signals around the first original origin and define a first result; performing a first inverse Fourier transform on the first result; applying a second digital filter to cut off signals around the second original origin and define a second result; and performing a second inverse Fourier transform on the second result, wherein the first reference beam-object beam angle is not equal to the second reference beam-object beam angle and a single digital image includes both the first spatially-heterodyned hologram and the second spatially-heterodyned hologram.

  16. Stabilization system for holographic recording of volume Bragg gratings using a corner cube retroreflector.

    PubMed

    Ott, Daniel B; Divliansky, Ivan B; Segall, Marc A; Glebov, Leonid B

    2014-02-20

    Volume Bragg gratings serve an important role in laser development as devices that are able to manipulate both the wavelength and angular spectrum of light. A common method for producing gratings is holographic recording of a two collimated beam interference pattern in a photosensitive material. This process requires stability of the recording system at a level of a fraction of the recording wavelength. A new method for measuring and stabilizing the phase of the recording beams is presented that is extremely flexible and simple to integrate into an existing holographic recording setup and independent of the type of recording media. It is shown that the presented method increases visibility of an interference pattern and for photo-thermo-refractive glass enables enhancement of the spatial refractive index modulation. The use of this technique allows for longer recording times that can lead to the use of expanded recording beams for large aperture gratings.

  17. Analysis of laminated beams with a layer-wise constant shear theory

    NASA Astrophysics Data System (ADS)

    Davalos, Julio F.; Kim, Youngchan; Barbero, Ever J.

    Based on generalized laminate plate theory, the formulation of a one-dimensional beam finite element with layer-wise constant shear (BLCS) is presented. The linear layer-wise representation of in-plane displacements permit accurate computation of normal stresses and transverse shear stresses on each layer for laminated beams with dissimilar ply stiffnesses. The BLCS formulation is equivalent to a first-order shear deformation beam theory (Timoshenko beam theory) on each layer. For the accurate computation of interlaminar shear stresses, the layer-wise constant shear stresses obtained from constitutive relations are transformed into parabolic shear stress distributions in a post-processing operation described in detail. The accuracy of the BLCS element is demonstrated by solving several numerical examples reported in the literature. While retaining the simplicity of a laminated beam theory, the element predicts results as accurate as much more complex elasticity analyses, and it is suitable to model frame-type structures.

  18. Picosecond beam monitor

    DOEpatents

    Schutt, D.W.; Beck, G.O.

    1974-01-01

    The current in the beam of a particle accelerator is monitored with picosecond resolution by causing the beam to impinge upon the center conductor of a coaxial line, generating a pulse of electromagnetic energy in response thereto. This pulse is detected by means such as a sampling oscilloscope. (Official Gazette)

  19. Ion Beam Propulsion Study

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Ion Beam Propulsion Study was a joint high-level study between the Applied Physics Laboratory operated by NASA and ASRC Aerospace at Kennedy Space Center, Florida, and Berkeley Scientific, Berkeley, California. The results were promising and suggested that work should continue if future funding becomes available. The application of ion thrusters for spacecraft propulsion is limited to quite modest ion sources with similarly modest ion beam parameters because of the mass penalty associated with the ion source and its power supply system. Also, the ion source technology has not been able to provide very high-power ion beams. Small ion beam propulsion systems were used with considerable success. Ion propulsion systems brought into practice use an onboard ion source to form an energetic ion beam, typically Xe+ ions, as the propellant. Such systems were used for steering and correction of telecommunication satellites and as the main thruster for the Deep Space 1 demonstration mission. In recent years, "giant" ion sources were developed for the controlled-fusion research effort worldwide, with beam parameters many orders of magnitude greater than the tiny ones of conventional space thruster application. The advent of such huge ion beam sources and the need for advanced propulsion systems for exploration of the solar system suggest a fresh look at ion beam propulsion, now with the giant fusion sources in mind.

  20. Beam Injection into RHIC

    NASA Astrophysics Data System (ADS)

    Fischer, W.; Hahn, H.; Mackay, W. W.; Tsoupas, N.

    1997-05-01

    During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. We describe the injection zone and its bottlenecks, the application program to steer the beam and the injection kickers. We report on the commissioning of the injection systems and on measurements of the kickers.

  1. Laser beam generating apparatus

    DOEpatents

    Warner, B.E.; Duncan, D.B.

    1994-02-15

    Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus is described. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 7 figures.

  2. Experiments with isomeric beams

    NASA Astrophysics Data System (ADS)

    Pfützner, M.; Grzywacz, R.; Lewitowicz, M.; Rykaczewski, K.

    1997-02-01

    The results of the search for μs-isomers performed with 112Sn and 86Kr beams at 60 MeV/nucleon with the LISE3 spectrometer at GANIL are summarized. Planned extension of these studies to high energy fragmentation reactions with the FRS separator at GSI is described. Some perspectives for experiments with isomeric beams at GSI are mentioned.

  3. Beam Diagnostics for FACET

    SciTech Connect

    Li, S.Z.; Hogan, M.J.; /SLAC

    2011-08-19

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

  4. Laser beam generating apparatus

    DOEpatents

    Warner, B.E.; Duncan, D.B.

    1993-12-28

    Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 11 figures.

  5. A Investigation of Radiotherapy Electron Beams Using Monte Carlo Techniques

    NASA Astrophysics Data System (ADS)

    Ding, George X.

    1995-01-01

    Radiotherapy electron beams are more complicated than photon beams due to variations in the beam production, the scattering of low-energy electrons, and the presence contaminant photons. The detailed knowledge of a radiotherapy beam is essential to an accurate calculation of dose distribution for a treatment planning system. This investigation aims to enhance our understanding of radiotherapy beams by focusing on electron beams used in radiotherapy. It starts with a description of the Monte Carlo simulation code, BEAM, and a detailed simulation of an accelerator head to obtain realistic radiotherapy beams. The simulation covers electron beams from various accelerators, including the NRC research accelerator, the NPL (UK), accelerator, A Varian Clinac 2100C, a Philips SL75-20, a Siemens KD2, an AECL Therac 20, and a Scanditronix MM50. The beam energies range from 4 to 50 MeV. The EGS4 user code, BEAM, is extensively benchmarked against experiment by comparing calculated dose distributions with measured dose distributions in water. The simulated beams are analyzed to obtain the characteristics of various electron beams from a variety of accelerators. The simulated beams are also used as inputs to calculate the following parameters: the mean electron energy, the most probable energy, the energy-range relationships, the depth-scaling factor to convert depths in plastic to water-equivalent depths, the water-to-air stopping-power ratios, and the electron fluence correction factors used to convert dose measured in plastics to dose in water. These parameters are essential for electron beam dosimetry. The results from this study can be applied in cancer clinics to improve the accuracy of the absolute dosimetry. The simulation also provides information about the backscatter into the beam monitor chamber, and predicts the influence on the beam output factors. This investigation presents comprehensive data on the clinical electron beams, and answers many questions which could

  6. HAWC2 and BeamDyn: Comparison Between Beam Structural Models for Aero-Servo-Elastic Frameworks: Preprint

    SciTech Connect

    Pavese, Christian; Kim, Taeseong; Wang, Qi; Jonkman, Jason; Sprague, Michael A.

    2016-08-01

    This work presents a comparison of two beam codes for aero-servo-elastic frameworks: a new structural model for the aeroelastic code HAWC2 and a new nonlinear beam model, BeamDyn, for the aeroelastic modularization framework FAST v8. The main goal is to establish the suitability of the two approaches to model the structural behaviour of modern wind turbine blades in operation. Through a series of benchmarking structural cases of increasing complexity, the capability of the two codes to simulate highly nonlinear effects is investigated and analyzed. Results show that even though the geometrically exact beam theory can better model effects such as very large deflections, rotations, and structural couplings, an approach based on a multi-body formulation assembled through linear elements is capable of computing accurate solutions for typical nonlinear beam theory benchmarking cases.

  7. HAWC2 and BeamDyn: Comparison Between Beam Structural Models for Aero-Servo-Elastic Frameworks

    SciTech Connect

    Pavese, Christian; Wang, Qi; Kim, Taeseong; Jonkman, Jason; Sprague, Michael A.

    2016-07-01

    This work presents a comparison of two beam codes for aero-servo-elastic frameworks: a new structural model for the aeroelastic code HAWC2 and a new nonlinear beam model, BeamDyn, for the aeroelastic modularization framework FAST v8. The main goal is to establish the suitability of the two approaches to model the structural behaviour of modern wind turbine blades in operation. Through a series of benchmarking structural cases of increasing complexity, the capability of the two codes to simulate highly nonlinear effects is investigated and analyzed. Results show that even though the geometrically exact beam theory can better model effects such as very large deflections, rotations, and structural couplings, an approach based on a multi-body formulation assembled through linear elements is capable of computing accurate solutions for typical nonlinear beam theory benchmarking cases.

  8. Laser beam alignment system

    DOEpatents

    Kasner, William H.; Racki, Daniel J.; Swenson, Clark E.

    1984-01-01

    A plurality of pivotal reflectors direct a high-power laser beam onto a workpiece, and a rotatable reflector is movable to a position wherein it intercepts the beam and deflects a major portion thereof away from its normal path, the remainder of the beam passing to the pivotal reflectors through an aperture in the rotating reflector. A plurality of targets are movable to positions intercepting the path of light traveling to the pivotal reflectors, and a preliminary adjustment of the latter is made by use of a low-power laser beam reflected from the rotating reflector, after which the same targets are used to make a final adjustment of the pivotal reflectors with the portion of the high-power laser beam passed through the rotating reflector.

  9. Entangled vector vortex beams

    NASA Astrophysics Data System (ADS)

    D'Ambrosio, Vincenzo; Carvacho, Gonzalo; Graffitti, Francesco; Vitelli, Chiara; Piccirillo, Bruno; Marrucci, Lorenzo; Sciarrino, Fabio

    2016-09-01

    Light beams having a vectorial field structure, or polarization, that varies over the transverse profile and a central optical singularity are called vector vortex (VV) beams and may exhibit specific properties such as focusing into "light needles" or rotation invariance. VV beams have already found applications in areas ranging from microscopy to metrology, optical trapping, nano-optics, and quantum communication. Individual photons in such beams exhibit a form of single-particle quantum entanglement between different degrees of freedom. On the other hand, the quantum states of two photons can be also entangled with each other. Here, we combine these two concepts and demonstrate the generation of quantum entanglement between two photons that are both in VV states: a form of entanglement between two complex vectorial fields. This result may lead to quantum-enhanced applications of VV beams as well as to quantum information protocols fully exploiting the vectorial features of light.

  10. Multisegment coherent beam combining

    NASA Astrophysics Data System (ADS)

    Neal, Daniel R.; Tucker, Steve D.; Morgan, R.; Smith, Tony G.; Warren, Mial E.; Gruetzner, James K.; Rosenthal, R. R.; Bentley, A. E.

    1995-08-01

    Scaling laser systems to large sizes for power beaming and other applications can sometimes be simplified by combining a number of smaller lasers. However, to fully utilize this scaling, coherent beam combination is necessary. This requires measuring and controlling each beam's pointing and phase relative to adjacent beams using an adaptive optical system. We have built a sub-scale brass-board to evaluate various methods for beam-combining. It includes a segmented adaptive optic and several different specialized wavefront sensors that are fabricated using diffractive optics methods. We have evaluated a number of different phasing algorithms, including hierarchical and matrix methods, and have demonstrated phasing of several elements. The system is currently extended to a large number of segments to evaluate various scaling methodologies.

  11. Beam director design report

    SciTech Connect

    Younger, F.C.

    1986-08-01

    A design and fabrication effort for a beam director is documented. The conceptual design provides for the beam to pass first through a bending and focusing system (or ''achromat''), through a second achromat, through an air-to-vacuum interface (the ''beam window''), and finally through the vernier steering system. Following an initial concept study for a beam director, a prototype permanent magnet 30/sup 0/ beam-bending achromat and prototype vernier steering magnet were designed and built. In volume II, copies are included of the funding instruments, requests for quotations, purchase orders, a complete set of as-built drawings, magnetic measurement reports, the concept design report, and the final report on the design and fabrication project. (LEW)

  12. Distributed processing (DP) based e-beam lithography simulation with long range correction algorithm in e-beam machine

    NASA Astrophysics Data System (ADS)

    Ki, Won-Tai; Choi, Ji-Hyeon; Kim, Byung-Gook; Woo, Sang-Gyun; Cho, Han-Ku

    2008-05-01

    As the design rule with wafer process is getting smaller down below 50nm node, the specification of CDs on a mask is getting more tightened. Therefore, more tight and accurate E-Beam Lithography simulation is highly required in these days. However, in reality most of E-Beam simulation cases, there is a trade-off relationship between the accuracy and the simulation speed. Moreover, the necessity of full chip based simulation has been increasing in order to estimate more accurate mask CDs based on real process condition. Therefore, without consideration of long range correction algorithm such as fogging effect and loading effect correction in E-beam machine, it would be impossible and meaningless to pursue the full chip based simulation. In this paper, we introduce a breakthrough method to overcome the obstacles of E-Beam simulation. In-house E-beam simulator, ELIS (E-beam LIthography Simulator), has been upgraded to solve these problems. First, DP (Distributed Processing) strategy was applied to improve calculation speed. Secondly, the long range correction algorithm of E-beam machine was also applied to compute intensity of exposure on a full chip based (Mask). Finally, ELIS-DP has been evaluated possibility of expecting or analyzing CDs on full chip base.

  13. Does a pneumotach accurately characterize voice function?

    NASA Astrophysics Data System (ADS)

    Walters, Gage; Krane, Michael

    2016-11-01

    A study is presented which addresses how a pneumotach might adversely affect clinical measurements of voice function. A pneumotach is a device, typically a mask, worn over the mouth, in order to measure time-varying glottal volume flow. By measuring the time-varying difference in pressure across a known aerodynamic resistance element in the mask, the glottal volume flow waveform is estimated. Because it adds aerodynamic resistance to the vocal system, there is some concern that using a pneumotach may not accurately portray the behavior of the voice. To test this hypothesis, experiments were performed in a simplified airway model with the principal dimensions of an adult human upper airway. A compliant constriction, fabricated from silicone rubber, modeled the vocal folds. Variations of transglottal pressure, time-averaged volume flow, model vocal fold vibration amplitude, and radiated sound with subglottal pressure were performed, with and without the pneumotach in place, and differences noted. Acknowledge support of NIH Grant 2R01DC005642-10A1.

  14. Accurate method for computing correlated color temperature.

    PubMed

    Li, Changjun; Cui, Guihua; Melgosa, Manuel; Ruan, Xiukai; Zhang, Yaoju; Ma, Long; Xiao, Kaida; Luo, M Ronnier

    2016-06-27

    For the correlated color temperature (CCT) of a light source to be estimated, a nonlinear optimization problem must be solved. In all previous methods available to compute CCT, the objective function has only been approximated, and their predictions have achieved limited accuracy. For example, different unacceptable CCT values have been predicted for light sources located on the same isotemperature line. In this paper, we propose to compute CCT using the Newton method, which requires the first and second derivatives of the objective function. Following the current recommendation by the International Commission on Illumination (CIE) for the computation of tristimulus values (summations at 1 nm steps from 360 nm to 830 nm), the objective function and its first and second derivatives are explicitly given and used in our computations. Comprehensive tests demonstrate that the proposed method, together with an initial estimation of CCT using Robertson's method [J. Opt. Soc. Am. 58, 1528-1535 (1968)], gives highly accurate predictions below 0.0012 K for light sources with CCTs ranging from 500 K to 106 K.

  15. Accurate Theoretical Thermochemistry for Fluoroethyl Radicals.

    PubMed

    Ganyecz, Ádám; Kállay, Mihály; Csontos, József

    2017-02-09

    An accurate coupled-cluster (CC) based model chemistry was applied to calculate reliable thermochemical quantities for hydrofluorocarbon derivatives including radicals 1-fluoroethyl (CH3-CHF), 1,1-difluoroethyl (CH3-CF2), 2-fluoroethyl (CH2F-CH2), 1,2-difluoroethyl (CH2F-CHF), 2,2-difluoroethyl (CHF2-CH2), 2,2,2-trifluoroethyl (CF3-CH2), 1,2,2,2-tetrafluoroethyl (CF3-CHF), and pentafluoroethyl (CF3-CF2). The model chemistry used contains iterative triple and perturbative quadruple excitations in CC theory, as well as scalar relativistic and diagonal Born-Oppenheimer corrections. To obtain heat of formation values with better than chemical accuracy perturbative quadruple excitations and scalar relativistic corrections were inevitable. Their contributions to the heats of formation steadily increase with the number of fluorine atoms in the radical reaching 10 kJ/mol for CF3-CF2. When discrepancies were found between the experimental and our values it was always possible to resolve the issue by recalculating the experimental result with currently recommended auxiliary data. For each radical studied here this study delivers the best heat of formation as well as entropy data.

  16. Accurate, reliable prototype earth horizon sensor head

    NASA Technical Reports Server (NTRS)

    Schwarz, F.; Cohen, H.

    1973-01-01

    The design and performance is described of an accurate and reliable prototype earth sensor head (ARPESH). The ARPESH employs a detection logic 'locator' concept and horizon sensor mechanization which should lead to high accuracy horizon sensing that is minimally degraded by spatial or temporal variations in sensing attitude from a satellite in orbit around the earth at altitudes in the 500 km environ 1,2. An accuracy of horizon location to within 0.7 km has been predicted, independent of meteorological conditions. This corresponds to an error of 0.015 deg-at 500 km altitude. Laboratory evaluation of the sensor indicates that this accuracy is achieved. First, the basic operating principles of ARPESH are described; next, detailed design and construction data is presented and then performance of the sensor under laboratory conditions in which the sensor is installed in a simulator that permits it to scan over a blackbody source against background representing the earth space interface for various equivalent plant temperatures.

  17. Accurate methods for large molecular systems.

    PubMed

    Gordon, Mark S; Mullin, Jonathan M; Pruitt, Spencer R; Roskop, Luke B; Slipchenko, Lyudmila V; Boatz, Jerry A

    2009-07-23

    Three exciting new methods that address the accurate prediction of processes and properties of large molecular systems are discussed. The systematic fragmentation method (SFM) and the fragment molecular orbital (FMO) method both decompose a large molecular system (e.g., protein, liquid, zeolite) into small subunits (fragments) in very different ways that are designed to both retain the high accuracy of the chosen quantum mechanical level of theory while greatly reducing the demands on computational time and resources. Each of these methods is inherently scalable and is therefore eminently capable of taking advantage of massively parallel computer hardware while retaining the accuracy of the corresponding electronic structure method from which it is derived. The effective fragment potential (EFP) method is a sophisticated approach for the prediction of nonbonded and intermolecular interactions. Therefore, the EFP method provides a way to further reduce the computational effort while retaining accuracy by treating the far-field interactions in place of the full electronic structure method. The performance of the methods is demonstrated using applications to several systems, including benzene dimer, small organic species, pieces of the alpha helix, water, and ionic liquids.

  18. Accurate equilibrium structures for piperidine and cyclohexane.

    PubMed

    Demaison, Jean; Craig, Norman C; Groner, Peter; Écija, Patricia; Cocinero, Emilio J; Lesarri, Alberto; Rudolph, Heinz Dieter

    2015-03-05

    Extended and improved microwave (MW) measurements are reported for the isotopologues of piperidine. New ground state (GS) rotational constants are fitted to MW transitions with quartic centrifugal distortion constants taken from ab initio calculations. Predicate values for the geometric parameters of piperidine and cyclohexane are found from a high level of ab initio theory including adjustments for basis set dependence and for correlation of the core electrons. Equilibrium rotational constants are obtained from GS rotational constants corrected for vibration-rotation interactions and electronic contributions. Equilibrium structures for piperidine and cyclohexane are fitted by the mixed estimation method. In this method, structural parameters are fitted concurrently to predicate parameters (with appropriate uncertainties) and moments of inertia (with uncertainties). The new structures are regarded as being accurate to 0.001 Å and 0.2°. Comparisons are made between bond parameters in equatorial piperidine and cyclohexane. Another interesting result of this study is that a structure determination is an effective way to check the accuracy of the ground state experimental rotational constants.

  19. Accurate lineshape spectroscopy and the Boltzmann constant

    PubMed Central

    Truong, G.-W.; Anstie, J. D.; May, E. F.; Stace, T. M.; Luiten, A. N.

    2015-01-01

    Spectroscopy has an illustrious history delivering serendipitous discoveries and providing a stringent testbed for new physical predictions, including applications from trace materials detection, to understanding the atmospheres of stars and planets, and even constraining cosmological models. Reaching fundamental-noise limits permits optimal extraction of spectroscopic information from an absorption measurement. Here, we demonstrate a quantum-limited spectrometer that delivers high-precision measurements of the absorption lineshape. These measurements yield a very accurate measurement of the excited-state (6P1/2) hyperfine splitting in Cs, and reveals a breakdown in the well-known Voigt spectral profile. We develop a theoretical model that accounts for this breakdown, explaining the observations to within the shot-noise limit. Our model enables us to infer the thermal velocity dispersion of the Cs vapour with an uncertainty of 35 p.p.m. within an hour. This allows us to determine a value for Boltzmann's constant with a precision of 6 p.p.m., and an uncertainty of 71 p.p.m. PMID:26465085

  20. Accurate upper body rehabilitation system using kinect.

    PubMed

    Sinha, Sanjana; Bhowmick, Brojeshwar; Chakravarty, Kingshuk; Sinha, Aniruddha; Das, Abhijit

    2016-08-01

    The growing importance of Kinect as a tool for clinical assessment and rehabilitation is due to its portability, low cost and markerless system for human motion capture. However, the accuracy of Kinect in measuring three-dimensional body joint center locations often fails to meet clinical standards of accuracy when compared to marker-based motion capture systems such as Vicon. The length of the body segment connecting any two joints, measured as the distance between three-dimensional Kinect skeleton joint coordinates, has been observed to vary with time. The orientation of the line connecting adjoining Kinect skeletal coordinates has also been seen to differ from the actual orientation of the physical body segment. Hence we have proposed an optimization method that utilizes Kinect Depth and RGB information to search for the joint center location that satisfies constraints on body segment length and as well as orientation. An experimental study have been carried out on ten healthy participants performing upper body range of motion exercises. The results report 72% reduction in body segment length variance and 2° improvement in Range of Motion (ROM) angle hence enabling to more accurate measurements for upper limb exercises.

  1. Noninvasive hemoglobin monitoring: how accurate is enough?

    PubMed

    Rice, Mark J; Gravenstein, Nikolaus; Morey, Timothy E

    2013-10-01

    Evaluating the accuracy of medical devices has traditionally been a blend of statistical analyses, at times without contextualizing the clinical application. There have been a number of recent publications on the accuracy of a continuous noninvasive hemoglobin measurement device, the Masimo Radical-7 Pulse Co-oximeter, focusing on the traditional statistical metrics of bias and precision. In this review, which contains material presented at the Innovations and Applications of Monitoring Perfusion, Oxygenation, and Ventilation (IAMPOV) Symposium at Yale University in 2012, we critically investigated these metrics as applied to the new technology, exploring what is required of a noninvasive hemoglobin monitor and whether the conventional statistics adequately answer our questions about clinical accuracy. We discuss the glucose error grid, well known in the glucose monitoring literature, and describe an analogous version for hemoglobin monitoring. This hemoglobin error grid can be used to evaluate the required clinical accuracy (±g/dL) of a hemoglobin measurement device to provide more conclusive evidence on whether to transfuse an individual patient. The important decision to transfuse a patient usually requires both an accurate hemoglobin measurement and a physiologic reason to elect transfusion. It is our opinion that the published accuracy data of the Masimo Radical-7 is not good enough to make the transfusion decision.

  2. Accurate, reproducible measurement of blood pressure.

    PubMed Central

    Campbell, N R; Chockalingam, A; Fodor, J G; McKay, D W

    1990-01-01

    The diagnosis of mild hypertension and the treatment of hypertension require accurate measurement of blood pressure. Blood pressure readings are altered by various factors that influence the patient, the techniques used and the accuracy of the sphygmomanometer. The variability of readings can be reduced if informed patients prepare in advance by emptying their bladder and bowel, by avoiding over-the-counter vasoactive drugs the day of measurement and by avoiding exposure to cold, caffeine consumption, smoking and physical exertion within half an hour before measurement. The use of standardized techniques to measure blood pressure will help to avoid large systematic errors. Poor technique can account for differences in readings of more than 15 mm Hg and ultimately misdiagnosis. Most of the recommended procedures are simple and, when routinely incorporated into clinical practice, require little additional time. The equipment must be appropriate and in good condition. Physicians should have a suitable selection of cuff sizes readily available; the use of the correct cuff size is essential to minimize systematic errors in blood pressure measurement. Semiannual calibration of aneroid sphygmomanometers and annual inspection of mercury sphygmomanometers and blood pressure cuffs are recommended. We review the methods recommended for measuring blood pressure and discuss the factors known to produce large differences in blood pressure readings. PMID:2192791

  3. Fast and accurate exhaled breath ammonia measurement.

    PubMed

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A; Risby, Terence H

    2014-06-11

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations.

  4. BEAMS3D Neutral Beam Injection Model

    NASA Astrophysics Data System (ADS)

    McMillan, Matthew; Lazerson, Samuel A.

    2014-09-01

    With the advent of applied 3D fields in Tokamaks and modern high performance stellarators, a need has arisen to address non-axisymmetric effects on neutral beam heating and fueling. We report on the development of a fully 3D neutral beam injection (NBI) model, BEAMS3D, which addresses this need by coupling 3D equilibria to a guiding center code capable of modeling neutral and charged particle trajectories across the separatrix and into the plasma core. Ionization, neutralization, charge-exchange, viscous slowing down, and pitch angle scattering are modeled with the ADAS atomic physics database. Elementary benchmark calculations are presented to verify the collisionless particle orbits, NBI model, frictional drag, and pitch angle scattering effects. A calculation of neutral beam heating in the NCSX device is performed, highlighting the capability of the code to handle 3D magnetic fields. Notice: this manuscript has been authored by Princeton University under Contract Number DE-AC02-09CH11466 with the US Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

  5. Accurate in-line CD metrology for nanometer semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Perng, Baw-Ching; Shieh, Jyu-Horng; Jang, S.-M.; Liang, M.-S.; Huang, Renee; Chen, Li-Chien; Hwang, Ruey-Lian; Hsu, Joe; Fong, David

    2006-03-01

    The need for absolute accuracy is increasing as semiconductor-manufacturing technologies advance to sub-65nm nodes, since device sizes are reducing to sub-50nm but offsets ranging from 5nm to 20nm are often encountered. While TEM is well-recognized as the most accurate CD metrology, direct comparison between the TEM data and in-line CD data might be misleading sometimes due to different statistical sampling and interferences from sidewall roughness. In this work we explore the capability of CD-AFM as an accurate in-line CD reference metrology. Being a member of scanning profiling metrology, CD-AFM has the advantages of avoiding e-beam damage and minimum sample damage induced CD changes, in addition to the capability of more statistical sampling than typical cross section metrologies. While AFM has already gained its reputation on the accuracy of depth measurement, not much data was reported on the accuracy of CD-AFM for CD measurement. Our main focus here is to prove the accuracy of CD-AFM and show its measuring capability for semiconductor related materials and patterns. In addition to the typical precision check, we spent an intensive effort on examining the bias performance of this CD metrology, which is defined as the difference between CD-AFM data and the best-known CD value of the prepared samples. We first examine line edge roughness (LER) behavior for line patterns of various materials, including polysilicon, photoresist, and a porous low k material. Based on the LER characteristics of each patterning, a method is proposed to reduce its influence on CD measurement. Application of our method to a VLSI nanoCD standard is then performed, and agreement of less than 1nm bias is achieved between the CD-AFM data and the standard's value. With very careful sample preparations and TEM tool calibration, we also obtained excellent correlation between CD-AFM and TEM for poly-CDs ranging from 70nm to 400nm. CD measurements of poly ADI and low k trenches are also

  6. Laser thermographic technologies for hard copy recording

    NASA Astrophysics Data System (ADS)

    Bessmel'tsev, Viktor P.; Baev, Sergej G.

    1995-04-01

    Methods of hard copies recording based on thermal interaction of the beam from CO2 or YAG lasers with various kinds of films on any substrates have been developed. The recording processes are single-step and require no additional development. Among them are: (1) Laser thermodestruction of thin mask layers or of a material surface on any kinds of substrates. (2) Laser thermochemical reactions of thermal decomposition of metal salts in solid state phase on a surface of various hygroscopic substrates. The laser recording devices using the methods, described above have been developed and are manufactured now; they allow one to record hard copies with a size of up to 27 X 31 inches, a resolution of 4000 dpi.

  7. 17 CFR 146.5 - Disclosure of requested information to individuals; fee for copies of records.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... record or records which shall be complete and accurate in all material aspects. (d) Where the disclosure... Trading Commission, Three Lafayette Centre, 1155 21st Street, NW., Washington, DC 20581. Payment should...

  8. Your Medical Records

    MedlinePlus

    ... Surgery? A Week of Healthy Breakfasts Shyness Your Medical Records KidsHealth > For Teens > Your Medical Records A ... Records? en español Tus historias clínicas What Are Medical Records? Each time you climb up on a ...

  9. Spoken Records. Third Edition.

    ERIC Educational Resources Information Center

    Roach, Helen

    Surveying 75 years of accomplishment in the field of spoken recording, this reference work critically evaluates commercially available recordings selected for excellence of execution, literary or historical merit, interest, and entertainment value. Some types of spoken records included are early recording, documentaries, lectures, interviews,…

  10. Diffraction of a Laser Beam.

    ERIC Educational Resources Information Center

    Jodoin, Ronald E.

    1979-01-01

    Investigates the effect of the nonuniform irradiance across a laser beam on diffraction of the beam, specifically the Fraunhofer diffraction of a laser beam with a Gaussian irradiance profile as it passes through a circular aperture. (GA)

  11. Effect of wavelength change in microholographic recording

    NASA Astrophysics Data System (ADS)

    Katayama, Ryuichi

    2016-09-01

    In microholographic recording, expensive laser diodes having no spectrum broadening (single mode) and no wavelength variation are used. On the other hand, in conventional optical disk systems, cheap laser diodes having spectrum broadening (multimode) and wavelength variation are used. It is a great advantage if the laser diodes for conventional optical disk systems can be used for microholographic recording. Therefore, the effect of wavelength change in microholographic recording was investigated through a numerical simulation. The laser diodes were modeled so that the full width at 1/e2 maximum of the spectrum was 0.8 nm and the center wavelength was 405 nm. The numerical aperture of the objective lenses was 0.85 and the thickness of the recording medium was 300 μm. The diffraction efficiency of the diffracted beam from a microhologram was calculated using the coupled wave theory and the following results were obtained. The diffraction efficiency decreased by three orders of magnitude by replacing single-mode laser diodes with multimode laser diodes, which makes it necessary to enhance the readout signal. The tolerance of the optical path length difference between the signal and reference beams was -50 110 μm, which makes it necessary to adjust the optical path length difference. The tolerance of the wavelength variation was 405 +/- 0.5 nm, which makes it necessary to select the laser diodes. The conclusion was that it is not practical to use the laser diodes for conventional optical disk systems for microholographic recording.

  12. Beam position and total current monitor for heavy ion fusion beams

    SciTech Connect

    Berners, D.; Reginato, L.L.

    1992-10-01

    Heavy Ion Fusion requires moderate currents, 1-10A, for a duration of about 1 {mu}s. For accurate beam transport, the center of charge must be located to within {plus_minus} 100 {mu}m. Beam position and intensity may be excited at frequencies approaching 10 MHz, and the monitoring system must have adequate bandwidth to respond at these frequencies. We have modified the Rogowski technique by using distributed reactance multiturn magnetic loops so that it is suitable for measuring current position as well as amplitude. Four identical stripline coils are wound one per quadrant around a non magnetic core. The sensitivity is similar to that of a lumped coil system, with the added advantage of increased bandwidth. The voltages induced on the four separate coils are compared and suitable signal conditioning is performed to recover beam position and intensity information.

  13. Beam position and total current monitor for heavy ion fusion beams

    SciTech Connect

    Berners, D.; Reginato, L.L.

    1992-10-01

    Heavy Ion Fusion requires moderate currents, 1-10A, for a duration of about 1 [mu]s. For accurate beam transport, the center of charge must be located to within [plus minus] 100 [mu]m. Beam position and intensity may be excited at frequencies approaching 10 MHz, and the monitoring system must have adequate bandwidth to respond at these frequencies. We have modified the Rogowski technique by using distributed reactance multiturn magnetic loops so that it is suitable for measuring current position as well as amplitude. Four identical stripline coils are wound one per quadrant around a non magnetic core. The sensitivity is similar to that of a lumped coil system, with the added advantage of increased bandwidth. The voltages induced on the four separate coils are compared and suitable signal conditioning is performed to recover beam position and intensity information.

  14. Accurate orbit propagation with planetary close encounters

    NASA Astrophysics Data System (ADS)

    Baù, Giulio; Milani Comparetti, Andrea; Guerra, Francesca

    2015-08-01

    We tackle the problem of accurately propagating the motion of those small bodies that undergo close approaches with a planet. The literature is lacking on this topic and the reliability of the numerical results is not sufficiently discussed. The high-frequency components of the perturbation generated by a close encounter makes the propagation particularly challenging both from the point of view of the dynamical stability of the formulation and the numerical stability of the integrator. In our approach a fixed step-size and order multistep integrator is combined with a regularized formulation of the perturbed two-body problem. When the propagated object enters the region of influence of a celestial body, the latter becomes the new primary body of attraction. Moreover, the formulation and the step-size will also be changed if necessary. We present: 1) the restarter procedure applied to the multistep integrator whenever the primary body is changed; 2) new analytical formulae for setting the step-size (given the order of the multistep, formulation and initial osculating orbit) in order to control the accumulation of the local truncation error and guarantee the numerical stability during the propagation; 3) a new definition of the region of influence in the phase space. We test the propagator with some real asteroids subject to the gravitational attraction of the planets, the Yarkovsky and relativistic perturbations. Our goal is to show that the proposed approach improves the performance of both the propagator implemented in the OrbFit software package (which is currently used by the NEODyS service) and of the propagator represented by a variable step-size and order multistep method combined with Cowell's formulation (i.e. direct integration of position and velocity in either the physical or a fictitious time).

  15. Important Nearby Galaxies without Accurate Distances

    NASA Astrophysics Data System (ADS)

    McQuinn, Kristen

    2014-10-01

    The Spitzer Infrared Nearby Galaxies Survey (SINGS) and its offspring programs (e.g., THINGS, HERACLES, KINGFISH) have resulted in a fundamental change in our view of star formation and the ISM in galaxies, and together they represent the most complete multi-wavelength data set yet assembled for a large sample of nearby galaxies. These great investments of observing time have been dedicated to the goal of understanding the interstellar medium, the star formation process, and, more generally, galactic evolution at the present epoch. Nearby galaxies provide the basis for which we interpret the distant universe, and the SINGS sample represents the best studied nearby galaxies.Accurate distances are fundamental to interpreting observations of galaxies. Surprisingly, many of the SINGS spiral galaxies have numerous distance estimates resulting in confusion. We can rectify this situation for 8 of the SINGS spiral galaxies within 10 Mpc at a very low cost through measurements of the tip of the red giant branch. The proposed observations will provide an accuracy of better than 0.1 in distance modulus. Our sample includes such well known galaxies as M51 (the Whirlpool), M63 (the Sunflower), M104 (the Sombrero), and M74 (the archetypal grand design spiral).We are also proposing coordinated parallel WFC3 UV observations of the central regions of the galaxies, rich with high-mass UV-bright stars. As a secondary science goal we will compare the resolved UV stellar populations with integrated UV emission measurements used in calibrating star formation rates. Our observations will complement the growing HST UV atlas of high resolution images of nearby galaxies.

  16. Accurate glucose detection in a small etalon

    NASA Astrophysics Data System (ADS)

    Martini, Joerg; Kuebler, Sebastian; Recht, Michael; Torres, Francisco; Roe, Jeffrey; Kiesel, Peter; Bruce, Richard

    2010-02-01

    We are developing a continuous glucose monitor for subcutaneous long-term implantation. This detector contains a double chamber Fabry-Perot-etalon that measures the differential refractive index (RI) between a reference and a measurement chamber at 850 nm. The etalon chambers have wavelength dependent transmission maxima which dependent linearly on the RI of their contents. An RI difference of ▵n=1.5.10-6 changes the spectral position of a transmission maximum by 1pm in our measurement. By sweeping the wavelength of a single-mode Vertical-Cavity-Surface-Emitting-Laser (VCSEL) linearly in time and detecting the maximum transmission peaks of the etalon we are able to measure the RI of a liquid. We have demonstrated accuracy of ▵n=+/-3.5.10-6 over a ▵n-range of 0 to 1.75.10-4 and an accuracy of 2% over a ▵nrange of 1.75.10-4 to 9.8.10-4. The accuracy is primarily limited by the reference measurement. The RI difference between the etalon chambers is made specific to glucose by the competitive, reversible release of Concanavalin A (ConA) from an immobilized dextran matrix. The matrix and ConA bound to it, is positioned outside the optical detection path. ConA is released from the matrix by reacting with glucose and diffuses into the optical path to change the RI in the etalon. Factors such as temperature affect the RI in measurement and detection chamber equally but do not affect the differential measurement. A typical standard deviation in RI is +/-1.4.10-6 over the range 32°C to 42°C. The detector enables an accurate glucose specific concentration measurement.

  17. How flatbed scanners upset accurate film dosimetry

    NASA Astrophysics Data System (ADS)

    van Battum, L. J.; Huizenga, H.; Verdaasdonk, R. M.; Heukelom, S.

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2-2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red-green-blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film.

  18. Towards Accurate Application Characterization for Exascale (APEX)

    SciTech Connect

    Hammond, Simon David

    2015-09-01

    Sandia National Laboratories has been engaged in hardware and software codesign activities for a number of years, indeed, it might be argued that prototyping of clusters as far back as the CPLANT machines and many large capability resources including ASCI Red and RedStorm were examples of codesigned solutions. As the research supporting our codesign activities has moved closer to investigating on-node runtime behavior a nature hunger has grown for detailed analysis of both hardware and algorithm performance from the perspective of low-level operations. The Application Characterization for Exascale (APEX) LDRD was a project concieved of addressing some of these concerns. Primarily the research was to intended to focus on generating accurate and reproducible low-level performance metrics using tools that could scale to production-class code bases. Along side this research was an advocacy and analysis role associated with evaluating tools for production use, working with leading industry vendors to develop and refine solutions required by our code teams and to directly engage with production code developers to form a context for the application analysis and a bridge to the research community within Sandia. On each of these accounts significant progress has been made, particularly, as this report will cover, in the low-level analysis of operations for important classes of algorithms. This report summarizes the development of a collection of tools under the APEX research program and leaves to other SAND and L2 milestone reports the description of codesign progress with Sandia’s production users/developers.

  19. How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?

    PubMed Central

    An, Hyun-Sung; Dinkel, Danae M; Noble, John M; Lee, Jung-Min

    2016-01-01

    Background Heart rate (HR) monitors are valuable devices for fitness-orientated individuals. There has been a vast influx of optical sensing blood flow monitors claiming to provide accurate HR during physical activities. These monitors are worn on the arm and wrist to detect HR with photoplethysmography (PPG) techniques. Little is known about the validity of these wearable activity trackers. Aim Validate the Scosche Rhythm (SR), Mio Alpha (MA), Fitbit Charge HR (FH), Basis Peak (BP), Microsoft Band (MB), and TomTom Runner Cardio (TT) wireless HR monitors. Methods 50 volunteers (males: n=32, age 19–43 years; females: n=18, age 19–38 years) participated. All monitors were worn simultaneously in a randomised configuration. The Polar RS400 HR chest strap was the criterion measure. A treadmill protocol of one 30 min bout of continuous walking and running at 3.2, 4.8, 6.4, 8.0, and 9.6 km/h (5 min at each protocol speed) with HR manually recorded every minute was completed. Results For group comparisons, the mean absolute percentage error values were: 3.3%, 3.6%, 4.0%, 4.6%, 4.8% and 6.2% for TT, BP, RH, MA, MB and FH, respectively. Pearson product-moment correlation coefficient (r) was observed: r=0.959 (TT), r=0.956 (MB), r=0.954 (BP), r=0.933 (FH), r=0.930 (RH) and r=0.929 (MA). Results from 95% equivalency testing showed monitors were found to be equivalent to those of the criterion HR (±10% equivalence zone: 98.15–119.96). Conclusions The results demonstrate that the wearable activity trackers provide an accurate measurement of HR during walking and running activities. PMID:27900173

  20. [Introduction of a simple audio recording system to the operating room--experience at a small local hospital].

    PubMed

    Taniguchi, Ayano; Nakamura, Eriko; Yaegashi, Kazuhiro

    2012-10-01

    We developed a simple audio recording system using a small personal computer and free audio recording software that makes voice recordings for use in emergencies, particularly for emergency caesarean sections. The system makes a continuous audio recording while the patient receives medical treatment. The recording provides an accurate record of the anesthesia used during treatment. This audio recording system is useful as an auxiliary means of record keeping during medical emergencies.

  1. Experimental Testing of Dynamically Optimized Photoelectron Beams

    NASA Astrophysics Data System (ADS)

    Rosenzweig, J. B.; Cook, A. M.; Dunning, M.; England, R. J.; Musumeci, P.; Bellaveglia, M.; Boscolo, M.; Catani, L.; Cianchi, A.; Pirro, G. Di; Ferrario, M.; Fillipetto, D.; Gatti, G.; Palumbo, L.; Serafini, L.; Vicario, C.

    2007-09-01

    We discuss the design of and initial results from an experiment in space-charge dominated beam dynamics which explores a new regime of high-brightness electron beam generation at the SPARC (located at INFN-LNF, Frascati) photoinjector. The scheme under study employs the natural tendency in intense electron beams to configure themselves to produce a uniform density, giving a nearly ideal beam from the viewpoint of space charge-induced emittance. The experiments are aimed at testing the marriage of this idea with a related concept, emittance compensation, We show that the existing infrastructure at SPARC is nearly ideal for the proposed tests, and that this new regime of operating photoinjector may be the preferred method of obtaining highest brightness beams with lower energy spread. We discuss the design of the experiment, including developing of a novel time-dependent, aerogel-based imaging system. This system has been installed at SPARC, and first evidence for nearly uniformly filled ellipsoidal charge distributions recorded.

  2. Experimental Testing of Dynamically Optimized Photoelectron Beams

    NASA Astrophysics Data System (ADS)

    Rosenzweig, J. B.; Cook, A. M.; Dunning, M.; England, R. J.; Musumeci, P.; Bellaveglia, M.; Boscolo, M.; Catani, L.; Cianchi, A.; di Pirro, G.; Ferrario, M.; Fillipetto, D.; Gatti, G.; Palumbo, L.; Serafini, L.; Vicario, C.

    We discuss the design of and initial results from an experiment in space-charge dominated beam dynamics which explores a new regime of high-brightness electron beam generation at the SPARC (located at INFN-LNF, Frascati) photoinjector. The scheme under study employs the natural tendency in intense electron beams to configure themselves to produce a uniform density, giving a nearly ideal beam from the viewpoint of space charge-induced emittance. The experiments are aimed at testing the marriage of this idea with a related concept, emittance compensation, We show that the existing infrastructure at SPARC is nearly ideal for the proposed tests, and that this new regime of operating photoinjector may be the preferred method of obtaining highest brightness beams with lower energy spread. We discuss the design of the experiment, including developing of a novel time-dependent, aerogel-based imaging system. This system has been installed at SPARC, and first evidence for nearly uniformly filled ellipsoidal charge distributions recorded.

  3. Computation of beam propagation in turbulent field

    NASA Astrophysics Data System (ADS)

    Yang, Yao; Cen, Zhaofeng; Li, Xiaotong

    2016-10-01

    The split-step Fourier method (SSFM) is introduced to analyze the beam propagation in a relatively large-sized turbulent filed, whose refractive-index profile is already detected. The numerical method is achieved by fast Fourier transform (FFT).To obtain the optimal sampling number, we propose an adaptive spread-spectrum method as an optimization. The SSFM is widely used for solving the nonlinear Schrödinger equation [1].The advantage of the SSFM is apparently its simple formalism and suitability to our situation. The direct numerical solution of the Helmholtz equation, derived from this method, yields detailed information of the spatial and angular properties of the propagation beam. On the other hand, a set of approximations restrict its applicability, the requirements for the accurate application of the method are summarized and a set of formulas is generalized in this paper. The efficiency of the SSFM depends on the sampling number, the adaptive spread-spectrum method yields optimal sampling number to increase the computational efficiency .To testify the accuracy of our algorithm, we use graded-index medium as the turbulent filed, for the reason that the beam propagation in turbulent field with random refractive-index profile is ruleless and has no unified reference. The simulation result testifies our algorithm is tremendously accurate, capable of selecting the optimal N automatically and much more computationally efficient than the original algorithm.

  4. Stability of cooled beams

    NASA Astrophysics Data System (ADS)

    Bosser, J.; Carli, C.; Chanel, M.; Madsen, N.; Maury, S.; Möhl, D.; Tranquille, G.

    2000-02-01

    Because of their high density together with extremely small spreads in betatron frequency and momentum, cooled beams are very vulnerable to incoherent and coherent space-charge effects and instabilities. Moreover, the cooling system itself, i.e. the electron beam in the case of e-cooling, presents large linear and non-linear "impedances" to the circulating ion beam, in addition to the usual beam-environment coupling impedances of the storage ring. Beam blow-up and losses, attributed to such effects, have been observed in virtually all the existing electron cooling rings. The adverse effects seem to be more pronounced in those rings, like CELSIUS, that are equipped with a cooler capable of reaching the presently highest energy (100-300 keV electrons corresponding to 180-560 MeV protons). The stability conditions will be revisited with emphasis on the experience gained at LEAR. It will be argued that for all present coolers, three conditions are necessary (although probably not sufficient) for the stability of intense cold beams: (i) operation below transition energy, (ii) active damping to counteract coherent instability, and (iii) careful control of the e-beam neutralisation. An extrapolation to the future "medium energy coolers", planned to work for (anti)protons of several GeV, will also be attempted.

  5. Accurate sperm morphology assessment predicts sperm function.

    PubMed

    Abu Hassan Abu, D; Franken, D R; Hoffman, B; Henkel, R

    2012-05-01

    Sperm morphology has been associated with in vitro as well as in vivo fertilisation. The study aimed to evaluate the possible relation between the percentage of spermatozoa with normal morphology and the following sperm functional assays: (i) zona-induced acrosome reaction (ZIAR); (ii) DNA integrity; (iii) chromatin condensation; (iv) sperm apoptosis; and (v) fertilisation rates. Regression analysis was employed to calculate the association between morphology and different functional tests. Normal sperm morphology correlated significantly with the percentages of live acrosome-reacted spermatozoa in the ZIAR (r = 0.518; P < 0.0001; n = 92), DNA integrity (r = -0.515; P = 0.0018; n = 34), CMA(3) -positive spermatozoa (r = -0.745; P < 0.0001; n = 92), sperm apoptosis (r = -0.395; P = 0.0206; n = 34) and necrosis (r = -0.545; P = 0.0009; n = 34). Negative correlations existed between for the acrosome reaction, and DNA integrity, while negative associations were recorded with the percentages of CMA(3) -positive spermatozoa, apoptotic and necrotic spermatozoa. Sperm morphology is related to sperm dysfunction such as poor chromatin condensation, acrosome reaction and DNA integrity. Negative and significant correlations existed between normal sperm morphology and chromatin condensation, the percentage of spermatozoa with abnormal DNA and spermatozoa with apoptotic activity. The authors do not regard sperm morphology as the only test for the diagnosis of male fertility, but sperm morphology can serve as a valuable indicator of underlying dysfunction.

  6. CRYSTALLINE BEAMS AT HIGH ENERGIES.

    SciTech Connect

    WEI, J.; OKAMOTO, H.; YURI, Y.; SESSLER, A.; MACHIDA, S.

    2006-06-23

    Previously it was shown that by crystallizing each of the two counter-circulating beams, a much larger beam-beam tune shift can be tolerated during the beam-beam collisions; thus a higher luminosity can be reached for colliding beams [1]. On the other hand, crystalline beams can only be formed at energies below the transition energy ({gamma}{sub T}) of the accelerators [2]. In this paper, we investigate the formation of crystals in a high-{gamma}{sub T} lattice that also satisfies the maintenance condition for a crystalline beam [3].

  7. Beam distributions beyond RMS

    NASA Astrophysics Data System (ADS)

    Decker, F.-J.

    1995-05-01

    The beam is often represented only by its position (mean) and the width (rms=root mean squared) of its distribution. To achieve these beam parameters in a noisy condition with high backgrounds, a Gaussian distribution with offset (4 parameters) is fitted to the measured beam distribution. This gives a very robust answer and is not very sensitive to background subtraction techniques. To get higher moments of the distribution, like skew or kurtosis, a fitting function with one or two more parameters is desired which would model the higher moments. In this paper we will concentrate on an Asymmetric Gaussian and a Super Gaussian function that will give something like the skew and the kurtosis of the distribution. This information is used to quantify special beam distribution. Some are unwanted like beam tails (skew) from transverse wakefields, higher order dispersive aberrations or potential well distortion in a damping ring. A negative kurtosis of a beam distribution describes a more rectangular, compact shape like with an over-compressed beam in z or a closed to double-horned energy distribution, while a positive kurtosis looks more like a ``Christmas tree'' and can quantify a beam mismatch after filamentation. Besides the advantages of the quantification, there are some distributions which need a further investigation like long flat tails which create background particles in a detector. In particle simulations on the other hand a simple rms number might grossly overestimate the effective size (e.g. for producing luminosity) due to a few particles which are far away from the core. This can reduce the practical gain of a big theoretical improvement in the beam size.

  8. Beam distributions beyond RMS

    NASA Astrophysics Data System (ADS)

    Decker, F. J.

    1994-09-01

    The beam is often represented only by its position (mean) and the width (rms = root mean squared) of its distribution. To achieve these beam parameters in a noisy condition with high backgrounds, a Gaussian distribution with offset (4 parameters) is fitted to the measured beam distribution. This gives a very robust answer and is not very sensitive to background subtraction techniques. To get higher moments of the distribution, like skew or kurtosis, a fitting function with one or two more parameters is desired which would model the higher moments. In this paper we will concentrate on an Asymmetric Gaussian and a Super Gaussian function that will give something like the skew and the kurtosis of the distribution. This information is used to quantify special beam distribution. Some are unwanted like beam tails (skew) from transverse wakefields, higher order dispersive aberrations or potential well distortion in a damping ring. A negative kurtosis of a beam distribution describes a more rectangular, compact shape like with an over-compressed beam in z or a closed to double-homed energy distribution, while a positive kurtosis looks more like a 'Christmas tree' and can quantify a beam mismatch after filamentation. Besides the advantages of the quantification, there are some distributions which need a further investigation like long flat tails which create background particles in a detector. In particle simulations on the other hand a simple rms number might grossly overestimate the effective size (e.g. for producing luminosity) due to a few particles which are far away from the core. This can reduce the practical gain of a big theoretical improvement in the beam size.

  9. Beam distributions beyond RMS

    SciTech Connect

    Decker, F.J.

    1994-09-01

    The beam is often represented only by its position (mean) and the width (rms = root mean squared) of its distribution. To achieve these beam parameters in a noisy condition with high backgrounds, a Gaussian distribution with offset (4 parmeters) is fitted to the measured beam distribution. This gives a very robust answer and is not very sensitive to background subtraction techniques. To get higher moments of the distribution, like skew or kurtosis, a fitting function with one or two more parameters is desired which would model the higher moments. In this paper we will concentrate on an Asymmetric Gaussian and a Super Gaussian function that will give something like the skew and the kurtosis of the distribution. This information is used to quantify special beam distribution. Some are unwanted like beam tails (skew) from transverse wakefields, higher order dispersive aberrations or potential well distortion in a damping ring. A negative kurtosis of a beam distribution describes a more rectangular, compact shape like with an over-compressed beam in z or a closed to double-homed energy distribution, while a positive kurtosis looks more like a ``Christmas tree`` and can quantify a beam mismatch after filamentation. Besides the advantages of the quantification, there are some distributions which need a further investigation like long flat tails which create background particles in a detector. In particle simulations on the other hand a simple rms number might grossly overestimate the effective size (e.g. for producing luminosity) due to a few particles which are far away from the core. This can reduce the practical gain of a big theoretical improvement in the beam size.

  10. Heavy ion beam studies and imaging with a multiplane multiwire proportional chamber

    SciTech Connect

    Chu, W.T.; Alonso, J.R.; Tobias, C.A.

    1981-03-01

    A 16-plane multiwire proportional chamber is used to accurately measure intensity profiles of heavy ion beams at the Bevalac. An imaging capability has now been developed for the system, allowing for reconstruction of 3-dimensional representation of radiological objects using heavy ion beams.

  11. Beam Diagnostics Report for the Thermal Test Conducted on 3/9/2016

    SciTech Connect

    Holloway, Michael Andrew; Dalmas, Dale Allen

    2016-08-11

    The thermal test OTR data revealed several issues with the beam focus and the target window itself. The oxidation of the target window and the prominence of a scratch across the center of the window makes it impossible to accurately measure the beam profile and size.

  12. Imaging with a multiplane multiwire proportional chamber using heavy ion beams

    SciTech Connect

    Chu, W.T.; Alonso, J.R.; Tobias, C.A.

    1982-01-01

    A 16-plane multiwire proportional chamber has been developed to accurately map intensity profiles of heavy ion beams at the Bevalac. The imaging capability of the system has been tested for reconstruction of 3-dimensional representation of a canine thorax region using heavy ion beams.

  13. Simulations of beam-beam and beam-wire interactions in RHIC

    SciTech Connect

    Kim, Hyung J.; Sen, Tanaji; Abreu, Natalia P.; Fischer, Wolfram; /Brookhaven

    2009-02-01

    The beam-beam interaction is one of the dominant sources of emittance growth and luminosity lifetime deterioration. A current carrying wire has been proposed to compensate long-range beam-beam effects in the LHC and strong localized long-range beam-beam effects are experimentally investigated in the RHIC collider. Tune shift, beam transfer function, and beam loss rate are measured in dedicated experiments. In this paper, they report on simulations to study the effect of beam-wire interactions based on diffusive apertures, beam loss rates, and beam transfer function using a parallelized weak-strong beam simulation code (BBSIMC). The simulation results are compared with measurements performed in RHIC during 2007 and 2008.

  14. Extension of Ko Straight-Beam Displacement Theory to Deformed Shape Predictions of Slender Curved Structures

    NASA Technical Reports Server (NTRS)

    Ko, William L.; Fleischer, Van Tran

    2011-01-01

    The Ko displacement theory originally developed for shape predictions of straight beams is extended to shape predictions of curved beams. The surface strains needed for shape predictions were analytically generated from finite-element nodal stress outputs. With the aid of finite-element displacement outputs, mathematical functional forms for curvature-effect correction terms are established and incorporated into straight-beam deflection equations for shape predictions of both cantilever and two-point supported curved beams. The newly established deflection equations for cantilever curved beams could provide quite accurate shape predictions for different cantilever curved beams, including the quarter-circle cantilever beam. Furthermore, the newly formulated deflection equations for two-point supported curved beams could provide accurate shape predictions for a range of two-point supported curved beams, including the full-circular ring. Accuracy of the newly developed curved-beam deflection equations is validated through shape prediction analysis of curved beams embedded in the windward shallow spherical shell of a generic crew exploration vehicle. A single-point collocation method for optimization of shape predictions is discussed in detail

  15. Ion beam lithography system

    DOEpatents

    Leung, Ka-Ngo

    2005-08-02

    A maskless plasma-formed ion beam lithography tool provides for patterning of sub-50 nm features on large area flat or curved substrate surfaces. The system is very compact and does not require an accelerator column and electrostatic beam scanning components. The patterns are formed by switching beamlets on or off from a two electrode blanking system with the substrate being scanned mechanically in one dimension. This arrangement can provide a maskless nano-beam lithography tool for economic and high throughput processing.

  16. Ion beam accelerator system

    NASA Technical Reports Server (NTRS)

    Aston, Graeme (Inventor)

    1984-01-01

    A system is described that combines geometrical and electrostatic focusing to provide high ion extraction efficiency and good focusing of an accelerated ion beam. The apparatus includes a pair of curved extraction grids (16, 18) with multiple pairs of aligned holes positioned to direct a group of beamlets (20) along converging paths. The extraction grids are closely spaced and maintained at a moderate potential to efficiently extract beamlets of ions and allow them to combine into a single beam (14). An accelerator electrode device (22) downstream from the extraction grids, is at a much lower potential than the grids to accelerate the combined beam.

  17. Ion beam accelerator system

    NASA Technical Reports Server (NTRS)

    Aston, G. (Inventor)

    1981-01-01

    A system is described that combines geometrical and electrostatic focusing to provide high ion extraction efficiency and good focusing of an accelerated ion beam. The apparatus includes a pair of curved extraction grids with multiple pairs of aligned holes positioned to direct a group of beamlets along converging paths. The extraction grids are closely spaced and maintained at a moderate potential to efficiently extract beamlets of ions and allow them to combine into a single beam. An accelerator electrode device downstream from the extraction grids is at a much lower potential than the grids to accelerate the combined beam. The application of the system to ion implantation is mentioned.

  18. Beam Purification by Photodetachment

    SciTech Connect

    Liu, Yuan; Beene, James R; Havener, Charles C; Galindo-Uribarri, Alfredo {nmn}; Andersson, P.; Lindahl, A. O.; Hanstorp, D.; Forstner, Dr. Oliver; Gottwald, T.; Wendt, K.

    2012-01-01

    Ion beam purity is of crucial importance to many basic and applied studies. Selective photodetachment has been proposed to suppress unwanted species in negative ion beams while preserving the intensity of the species of interest. A highly efficient technique based on photodetachment in a gas-filled radio frequency quadrupole ion cooler has been demonstrated. In off-line experiments with stable ions, up to 104 times suppression of the isobar contaminants in a number of interesting radioactive negative ion beams has been demonstrated. For selected species, this technique promises experimental possibilities in studies on exotic nuclei, accelerator mass spectrometry, and fundamental properties of negative atomic and molecular ions.

  19. Ion beam thruster shield

    NASA Technical Reports Server (NTRS)

    Power, J. L. (Inventor)

    1976-01-01

    An ion thruster beam shield is provided that comprises a cylindrical housing that extends downstream from the ion thruster and a plurality of annular vanes which are spaced along the length of the housing, and extend inwardly from the interior wall of the housing. The shield intercepts and stops all charge exchange and beam ions, neutral propellant, and sputter products formed due to the interaction of beam and shield emanating from the ion thruster outside of a fixed conical angle from the thruster axis. Further, the shield prevents the sputter products formed during the operation of the engine from escaping the interior volume of the shield.

  20. Compact reflection holographic recording system with high angle multiplexing

    NASA Astrophysics Data System (ADS)

    Kanayasu, Mayumi; Yamada, Takehumi; Takekawa, Shunsuke; Akieda, Kensuke; Goto, Akiyo; Yamamoto, Manabu

    2011-02-01

    Holographic memory systems have been widely researched since 1963. However, the size of the drives required and the deterioration of reconstructed data resulting from shrinkage of the medium have made practical use of a hologram memory difficult. In light of this, we propose a novel holographic recording/reconstructing system: a dual-reference beam reflection system that is smaller than conventional systems such as the off-axis or co-axis types, and which is expected to increase the number of multiplexing in angle multiplexed recording. In this multiplex recording system, two laser beams are used as reference beams, and the recorded data are reconstructed stably, even if there is shrinkage of the recording medium. In this paper, a reflection holographic memory system is explained in detail. In addition, the change in angle selectivity resulting from shrinkage of the medium is analyzed using the laminated film three-dimensional simulation method. As a result, we demonstrate that a dual-reference beam multiplex recording system is effective in reducing the influence of medium shrinkage.

  1. Accurate Completion of Medical Report on Diagnosing Death.

    PubMed

    Savić, Slobodan; Alempijević, Djordje; Andjelić, Sladjana

    2015-01-01

    Diagnosing death and issuing a Death Diagnosing Form (DDF) represents an activity that carries a great deal of public responsibility for medical professionals of the Emergency Medical Services (EMS) and is perpetually exposed to the control of the general public. Diagnosing death is necessary so as to confirm true, to exclude apparent death and consequentially to avoid burying a person alive, i.e. apparently dead. These expert-methodological guidelines based on the most up-to-date and medically based evidence have the goal of helping the physicians of the EMS in accurately filling out a medical report on diagnosing death. If the outcome of applied cardiopulmonary resuscitation measures is negative or when the person is found dead, the physician is under obligation to diagnose death and correctly fill out the DDF. It is also recommended to perform electrocardiography (EKG) and record asystole in at least two leads. In the process of diagnostics and treatment, it is a moral obligation of each Belgrade EMS physician to apply all available achievements and knowledge of modern medicine acquired from extensive international studies, which have been indeed the major theoretical basis for the creation of these expert-methodological guidelines. Those acting differently do so in accordance with their conscience and risk professional, and even criminal sanctions.

  2. ELODIE: A spectrograph for accurate radial velocity measurements.

    NASA Astrophysics Data System (ADS)

    Baranne, A.; Queloz, D.; Mayor, M.; Adrianzyk, G.; Knispel, G.; Kohler, D.; Lacroix, D.; Meunier, J.-P.; Rimbaud, G.; Vin, A.

    1996-10-01

    The fibre-fed echelle spectrograph of Observatoire de Haute-Provence, ELODIE, is presented. This instrument has been in operation since the end of 1993 on the 1.93 m telescope. ELODIE is designed as an updated version of the cross-correlation spectrometer CORAVEL, to perform very accurate radial velocity measurements such as needed in the search, by Doppler shift, for brown-dwarfs or giant planets orbiting around nearby stars. In one single exposure a spectrum at a resolution of 42000 (λ/{DELTA}λ) ranging from 3906A to 6811A is recorded on a 1024x1024 CCD. This performance is achieved by using a tanθ=4 echelle grating and a combination of a prism and a grism as cross-disperser. An automatic on-line data treatment reduces all the ELODIE echelle spectra and computes cross-correlation functions. The instrument design and the data reduction algorithms are described in this paper. The efficiency and accuracy of the instrument and its long term instrumental stability allow us to measure radial velocities with an accuracy better than 15m/s for stars up to 9th magnitude in less than 30 minutes exposure time. Observations of 16th magnitude stars are also possible to measure velocities at about 1km/s accuracy. For classic spectroscopic studies (S/N>100) 9th magnitude stars can be observed in one hour exposure time.

  3. Caution -- Beam Crossing Ahead

    SciTech Connect

    Barat, Kenneth L.

    2008-04-02

    There are times when a laser beam needs to cross between tables or even go from one room to another. This presents an interesting traffic-flow and safety challenge to both the laser safety officer and laser user. Fortunately it is a challenge that has several solutions But the simplest solution may not be the best one. For example, the simplest way to get a beam from one optical table to another is just to put a sturdy tube around it. That's a permanent solution, and it completely contains the laser beam. While this is laser safe, there can be egress issues if it blocks a walkway. One comment this author often hears is, 'We can just duck under the tube.' The fire marshal, as well as the laser safety officer, might have issues with this. Especially in the case of a darkened lab, a blocked walkway can present a hazard of its own. One good solution is to transport the beam from Point A to Point B through a fiberoptic cable, when that is possible. One should easily be able to run the fiber up and over any walkway or down through a conduit on the floor. An important concern often overlooked with fibers is a label at the termination end indicating disconnection may expose one to laser radiation. Suppose there's an experiment that is usually confined to a single optical table, but sometimes needs to expand to a second table. It's inconvenient to install a permanent tube between the tables, so some sort of temporary arrangement is desirable. I have often seen people casually lay a beam tube across support arms, and remove it when it's not needed. The problem with this approach is that there's no mechanism to prevent the beam from crossing if somebody's forgotten the tube, or if the tube gets knocked out of place. A better solution is a mechanism that only allows the beam to cross when the beam protection is in place. A swing shutter, or a guillotine and swing arm, are examples (Figures 1 and 2). Another alternative is a sensor, maybe a little microswitch, that activates a

  4. TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

    SciTech Connect

    A, Popescu I; Lobo, J; Sawkey, D; Svatos, M

    2014-06-15

    Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulations in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam

  5. Breakthrough: Record-Setting Cavity

    ScienceCinema

    Ciovati, Gianluigi

    2016-07-12

    Gianluigi "Gigi" Ciovati, a superconducting radiofrequency scientist, discusses how scientists at the U.S. Department of Energy's Jefferson Lab in Newport News, VA, used ARRA funds to fabricate a niobium cavity for superconducting radiofrequency accelerators that has set a world record for energy efficiency. Jefferson Lab's scientists developed a new, super-hot treatment process that could soon make it possible to produce cavities more quickly and at less cost, benefitting research and healthcare around the world. Accelerators are critical to our efforts to study the structure of matter that builds our visible universe. They also are used to produce medical isotopes and particle beams for diagnosing and eradicating disease. And they offer the potential to power future nuclear power plants that produce little or no radioactive waste.around the world. Accelerators are critical to our efforts to study the structure of matter that builds our visible universe. They also are used to produce medical isotopes and particle beams for diagnosing and eradicating disease. And they offer the potential to power future nuclear power plants that produce little or no radioactive waste.

  6. Breakthrough: Record-Setting Cavity

    SciTech Connect

    Ciovati, Gianluigi

    2012-03-01

    Gianluigi "Gigi" Ciovati, a superconducting radiofrequency scientist, discusses how scientists at the U.S. Department of Energy's Jefferson Lab in Newport News, VA, used ARRA funds to fabricate a niobium cavity for superconducting radiofrequency accelerators that has set a world record for energy efficiency. Jefferson Lab's scientists developed a new, super-hot treatment process that could soon make it possible to produce cavities more quickly and at less cost, benefitting research and healthcare around the world. Accelerators are critical to our efforts to study the structure of matter that builds our visible universe. They also are used to produce medical isotopes and particle beams for diagnosing and eradicating disease. And they offer the potential to power future nuclear power plants that produce little or no radioactive waste.around the world. Accelerators are critical to our efforts to study the structure of matter that builds our visible universe. They also are used to produce medical isotopes and particle beams for diagnosing and eradicating disease. And they offer the potential to power future nuclear power plants that produce little or no radioactive waste.

  7. Large energy-spread beam diagnostics through quadrupole scans

    SciTech Connect

    Frederico, Joel; Adli, Erik; Hogan, Mark; Raubenheimer, Tor

    2012-12-21

    The Facility for Advanced Accelerator and Experimental Tests (FACET) is a new user facility at the SLAC National Accelerator Laboratory, servicing next-generation accelerator experiments. The 1.5% RMS energy spread of the FACET beam causes large chromatic aberrations in optics. These aberrations necessitate updated quadrupole scan fits to remain accurate.

  8. Large energy-spread beam diagnostics through quadrupole scans

    SciTech Connect

    Frederico, Joel; Adli, Erik; Hogan, Mark; Raubenheimer, Tor

    2013-01-01

    The Facility for Advanced Accelerator and Experimental Tests (FACET) is a new user facility at the SLAC National Accelerator Laboratory, servicing next-generation accelerator experiments. The 1.5% RMS energy spread of the FACET beam causes large chromatic aberrations in optics. These aberrations necessitate updated quadrupole scan fits to remain accurate.

  9. Dosimetry of small fields for Therac 20 electron beams.

    PubMed

    Sharma, S C; Wilson, D L; Jose, B

    1984-01-01

    The Therac 20 medical linear accelerator produces electron beams of 6, 9, 13, 17, and 20 MeV. We measured depth dose, isodose curves, and output factors for small electron fields using an ionization chamber, film, and thermoluminescent dosimeters. Tables and graphs were generated from these measurements for accurate treatment planning of various blocked and open fields.

  10. LEDA BEAM DIAGNOSTICS INSTRUMENTATION: BEAM POSITION MONITORS

    SciTech Connect

    D. BARR; ET AL

    2000-05-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7-MeV and current of 100-mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS32OC40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  11. Neutral particle beam intensity controller

    DOEpatents

    Dagenhart, W.K.

    1984-05-29

    The neutral beam intensity controller is based on selected magnetic defocusing of the ion beam prior to neutralization. The defocused portion of the beam is dumped onto a beam dump disposed perpendicular to the beam axis. Selective defocusing is accomplished by means of a magnetic field generator disposed about the neutralizer so that the field is transverse to the beam axis. The magnetic field intensity is varied to provide the selected partial beam defocusing of the ions prior to neutralization. The desired focused neutral beam portion passes along the beam path through a defining aperture in the beam dump, thereby controlling the desired fraction of neutral particles transmitted to a utilization device without altering the kinetic energy level of the desired neutral particle fraction. By proper selection of the magnetic field intensity, virtually zero through 100% intensity control of the neutral beam is achieved.

  12. Parametric Modeling of Electron Beam Loss in Synchrotron Light Sources

    SciTech Connect

    Sayyar-Rodsari, B.; Schweiger, C.; Hartman, E.; Corbett, J.; Lee, M.; Lui, P.; Paterson, E.; /SLAC

    2007-11-28

    Synchrotron light is used for a wide variety of scientific disciplines ranging from physical chemistry to molecular biology and industrial applications. As the electron beam circulates, random single-particle collisional processes lead to decay of the beam current in time. We report a simulation study in which a combined neural network (NN) and first-principles (FP) model is used to capture the decay in beam current due to Touschek, Bremsstrahlung, and Coulomb effects. The FP block in the combined model is a parametric description of the beam current decay where model parameters vary as a function of beam operating conditions (e.g. vertical scraper position, RF voltage, number of the bunches, and total beam current). The NN block provides the parameters of the FP model and is trained (through constrained nonlinear optimization) to capture the variation in model parameters as operating condition of the beam changes. Simulation results will be presented to demonstrate that the proposed combined framework accurately models beam decay as well as variation to model parameters without direct access to parameter values in the model.

  13. Transmission beam characteristics of a Risso's dolphin (Grampus griseus).

    PubMed

    Smith, Adam B; Kloepper, Laura N; Yang, Wei-Cheng; Huang, Wan-Hsiu; Jen, I-Fan; Rideout, Brendan P; Nachtigall, Paul E

    2016-01-01

    The echolocation system of the Risso's dolphin (Grampus griseus) remains poorly studied compared to other odontocete species. In this study, echolocation signals were recorded from a stationary Risso's dolphin with an array of 16 hydrophones and the two-dimensional beam shape was explored using frequency-dependent amplitude plots. Click source parameters were similar to those already described for this species. Centroid frequency of click signals increased with increasing sound pressure level, while the beamwidth decreased with increasing center frequency. Analysis revealed primarily single-lobed, and occasionally vertically dual-lobed, beam shapes. Overall beam directivity was found to be greater than that of the harbor porpoise, bottlenose dolphin, and a false killer whale. The relationship between frequency content, beam directivity, and head size for this Risso's dolphin deviated from the trend described for other species. These are the first reported measurements of echolocation beam shape and directivity in G. griseus.

  14. Smoothing of the spectrum of fibre Bragg gratings in the Lloyd-interferometer recording scheme

    SciTech Connect

    Abdullina, S R; Vlasov, Aleksandr A; Babin, Sergei A

    2010-05-26

    The possibility of apodization of fibre Bragg gratings (FBGs) recorded in the region of interference of the two parts of a Gaussian beam in a Lloyd interferometer is considered. The reflection spectra of FBGs are numerically simulated for different parameters of the recording beam and its displacement with respect to the dividing axis in the interferometer. Aconsiderable suppression of sidelobe resonances in the FBG spectrum during the displacement of the beam centre with respect to the dividing axis by half the beam radius is predicted and experimentally demonstrated. It is shown that this is caused by the equating of the mean value of the refractive index in the FBG region. (fibres)

  15. Upgrade of the beam transport lines and the beam-abort system and development of a tune compensator in KEKB

    NASA Astrophysics Data System (ADS)

    Iida, Naoko; Kikuchi, Mitsuo; Mimashi, Toshihiro; Nakayama, Hisayoshi; Sakamoto, Yutaka; Satoh, Kotaro; Takasaki, Seiji; Tawada, Masafumi

    2013-03-01

    The KEKB collider achieved a maximum peak luminosity of 2.1×1034 cm-2 s-1 and an integrated luminosity of 1 ab-1 in its ten-year operation. Behind these glorious records there have been uncountable improvements in every subsystem. This paper describes the improvements in the beam transport line, injection kickers, septum magnets, the beam-abort system, and a newly developed pulsed-quadrupole system in detail.

  16. 21 CFR 211.188 - Batch production and control records.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Batch production and control records. 211.188 Section 211.188 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... production and control of each batch. These records shall include: (a) An accurate reproduction of...

  17. 30 CFR 250.466 - What records must I keep?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations..., legible, and accurate records for each well. You must keep drilling records onsite while drilling activities continue. After completion of drilling activities, you must keep all drilling and other...

  18. 30 CFR 250.466 - What records must I keep?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations..., legible, and accurate records for each well. You must keep drilling records onsite while drilling activities continue. After completion of drilling activities, you must keep all drilling and other...

  19. 30 CFR 250.466 - What records must I keep?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations..., legible, and accurate records for each well. You must keep drilling records onsite while drilling activities continue. After completion of drilling activities, you must keep all drilling and other...

  20. 41 CFR 128-50.101 - Inventory records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Regulations System (Continued) DEPARTMENT OF JUSTICE 50-SEIZED PERSONAL PROPERTY 50.1-Storage and Care of... the case name and number; (c) The location of storage of the property is recorded; (d) A well documented chain of custody is kept; and (e) All information in the inventory records is accurate and current....

  1. 7 CFR 58.139 - Record of tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) GRADING AND INSPECTION, GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General... Milk § 58.139 Record of tests. Accurate records listing the results of quality and drug residue...

  2. Tangent map analysis of the beam-beam interaction

    SciTech Connect

    Lee, S.Y.; Tepikian, S.

    1989-01-01

    We studied the tangent map of the beam-beam interaction and found no evidence of beam-beam instability for /epsilon/ = 0.04. Tracking study with tune modulation shows however large emittance growth due to the sum resonances. The emittance growth is due to the multiple crossing of the sum resonances. 12 refs., 7 figs.

  3. Beam-beam tuneshift during the TEVATRON squeeze

    SciTech Connect

    Mane, S.R.

    1988-11-01

    We calculate the beam-beam tuneshift during the squeeze of the beam in the Tevatron from injection to mini-beta. We find that for the beam emittances typically used, there is little variation of the tuneshift, in either plane, during the squeeze. 7 figs., 2 tabs.

  4. Planar Near-Field Phase Retrieval Using GPUs for Accurate THz Far-Field Prediction

    NASA Astrophysics Data System (ADS)

    Junkin, Gary

    2013-04-01

    With a view to using Phase Retrieval to accurately predict Terahertz antenna far-field from near-field intensity measurements, this paper reports on three fundamental advances that achieve very low algorithmic error penalties. The first is a new Gaussian beam analysis that provides accurate initial complex aperture estimates including defocus and astigmatic phase errors, based only on first and second moment calculations. The second is a powerful noise tolerant near-field Phase Retrieval algorithm that combines Anderson's Plane-to-Plane (PTP) with Fienup's Hybrid-Input-Output (HIO) and Successive Over-Relaxation (SOR) to achieve increased accuracy at reduced scan separations. The third advance employs teraflop Graphical Processing Units (GPUs) to achieve practically real time near-field phase retrieval and to obtain the optimum aperture constraint without any a priori information.

  5. Highly accurate spectral retardance characterization of a liquid crystal retarder including Fabry-Perot interference effects

    SciTech Connect

    Vargas, Asticio; Mar Sánchez-López, María del; García-Martínez, Pascuala; Arias, Julia; Moreno, Ignacio

    2014-01-21

    Multiple-beam Fabry-Perot (FP) interferences occur in liquid crystal retarders (LCR) devoid of an antireflective coating. In this work, a highly accurate method to obtain the spectral retardance of such devices is presented. On the basis of a simple model of the LCR that includes FP effects and by using a voltage transfer function, we show how the FP features in the transmission spectrum can be used to accurately retrieve the ordinary and extraordinary spectral phase delays, and the voltage dependence of the latter. As a consequence, the modulation characteristics of the device are fully determined with high accuracy by means of a few off-state physical parameters which are wavelength-dependent, and a single voltage transfer function that is valid within the spectral range of characterization.

  6. Accurate band-to-band registration of AOTF imaging spectrometer using motion detection technology

    NASA Astrophysics Data System (ADS)

    Zhou, Pengwei; Zhao, Huijie; Jin, Shangzhong; Li, Ningchuan

    2016-05-01

    This paper concerns the problem of platform vibration induced band-to-band misregistration with acousto-optic imaging spectrometer in spaceborne application. Registrating images of different bands formed at different time or different position is difficult, especially for hyperspectral images form acousto-optic tunable filter (AOTF) imaging spectrometer. In this study, a motion detection method is presented using the polychromatic undiffracted beam of AOTF. The factors affecting motion detect accuracy are analyzed theoretically, and calculations show that optical distortion is an easily overlooked factor to achieve accurate band-to-band registration. Hence, a reflective dual-path optical system has been proposed for the first time, with reduction of distortion and chromatic aberration, indicating the potential of higher registration accuracy. Consequently, a spectra restoration experiment using additional motion detect channel is presented for the first time, which shows the accurate spectral image registration capability of this technique.

  7. Beam-foil spectroscopy

    SciTech Connect

    Berry, H.G.; Hass, M.

    1982-01-01

    A brief survey of some applications of beam-foil spectroscopy is presented. Among the topics covered are lifetime and magnetic moment measurements, nuclear alignment, and polarized light production. (AIP)

  8. Bunched beam stochastic cooling

    SciTech Connect

    Wei, Jie.

    1992-01-01

    The scaling laws for bunched-beam stochastic cooling has been derived in terms of the optimum cooling rate and the mixing condition. In the case that particles occupy the entire sinusoidal rf bucket, the optimum cooling rate of the bunched beam is shown to be similar to that predicted from the coasting-beam theory using a beam of the same average density and mixing factor. However, in the case that particles occupy only the center of the bucket, the optimum rate decrease in proportion to the ratio of the bunch area to the bucket area. The cooling efficiency can be significantly improved if the synchrotron side-band spectrum is effectively broadened, e.g. by the transverse tune spread or by using a double rf system.

  9. Bunched beam stochastic cooling

    SciTech Connect

    Wei, Jie

    1992-09-01

    The scaling laws for bunched-beam stochastic cooling has been derived in terms of the optimum cooling rate and the mixing condition. In the case that particles occupy the entire sinusoidal rf bucket, the optimum cooling rate of the bunched beam is shown to be similar to that predicted from the coasting-beam theory using a beam of the same average density and mixing factor. However, in the case that particles occupy only the center of the bucket, the optimum rate decrease in proportion to the ratio of the bunch area to the bucket area. The cooling efficiency can be significantly improved if the synchrotron side-band spectrum is effectively broadened, e.g. by the transverse tune spread or by using a double rf system.

  10. Ion beam texturing

    NASA Technical Reports Server (NTRS)

    Hudson, W. R.

    1976-01-01

    A microscopic surface texture is created by sputter etching a surface while simultaneously sputter depositing a lower sputter yield material onto the surface. A xenon ion beam source has been used to perform this texturing process on samples as large as three centimeters in diameter. Ion beam textured surface structures have been characterized with SEM photomicrographs for a large number of materials including Cu, Al, Si, Ti, Ni, Fe, Stainless steel, Au, and Ag. Surfaces have been textured using a variety of low sputter yield materials - Ta, Mo, Nb, and Ti. The initial stages of the texture creation have been documented, and the technique of ion beam sputter removal of any remaining deposited material has been studied. A number of other texturing parameters have been studied such as the variation of the texture with ion beam power, surface temperature, and the rate of texture growth with sputter etching time.

  11. Pulsed ion beam source

    DOEpatents

    Greenly, John B.

    1997-01-01

    An improved pulsed ion beam source having a new biasing circuit for the fast magnetic field. This circuit provides for an initial negative bias for the field created by the fast coils in the ion beam source which pre-ionize the gas in the source, ionize the gas and deliver the gas to the proper position in the accelerating gap between the anode and cathode assemblies in the ion beam source. The initial negative bias improves the interaction between the location of the nulls in the composite magnetic field in the ion beam source and the position of the gas for pre-ionization and ionization into the plasma as well as final positioning of the plasma in the accelerating gap. Improvements to the construction of the flux excluders in the anode assembly are also accomplished by fabricating them as layered structures with a high melting point, low conductivity material on the outsides with a high conductivity material in the center.

  12. Focused ion beam system

    SciTech Connect

    Leung, K.; Gough, R.A.; Ji, Q.; Lee, Y.Y.

    1999-08-31

    A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.

  13. Final focus test beam

    SciTech Connect

    Not Available

    1991-03-01

    This report discusses the following: the Final Focus Test Beam Project; optical design; magnets; instrumentation; magnetic measurement and BPM calibration; mechanical alignment and stabilization; vacuum system; power supplies; control system; radiation shielding and personnel protection; infrastructure; and administration.

  14. Focused ion beam system

    DOEpatents

    Leung, Ka-Ngo; Gough, Richard A.; Ji, Qing; Lee, Yung-Hee Yvette

    1999-01-01

    A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.

  15. Comparison of PA imaging by narrow beam scanning and one-shot broad beam excitation

    NASA Astrophysics Data System (ADS)

    Xia, Jinjun; Wei, Chen-Wei; Huang, Lingyun; Pelivanov, I. M.; O'Donnell, Matthew

    2011-03-01

    Current systems designed for deep photoacoustic (PA) imaging typically use a low repetition rate, high power pulsed laser to provide a ns-scale pulse illuminating a large tissue volume. Acoustic signals recorded on each laser firing can be used to reconstruct a complete 2-D (3-D) image of sources of heat release within that region. Using broad-beam excitation, the maximum frame rate of the imaging system is restricted by the pulse repetition rate of the laser. An alternate illumination approach is proposed based on fast scanning by a low energy (~ 1 mJ) high repetition rate (up to a few kHz) narrow laser beam (~1 mm) along the tissue surface over a region of interest. A final PA image is produced from the summation of individual PA images reconstructed at each laser beam position. This concept can take advantage of high repetition rate fiber lasers to create PA images with much higher frame rates than current systems, enabling true real-time integration of photoacoustics with ultrasound imaging. As an initial proof of concept, we compare conventional broad beam illumination to a scanned beam approach in a simple model system. Two transparent teflon tubes with diameters of 1.6 mm and 0.8 mm were filled with ink having an absorption coefficient of 5 cm-1. These tubes were buried inside chicken breast tissue acting as an optical scattering medium. They were separated by 3 mm or 10 mm to test spatial and contrast resolution for the two scan formats. The excitation wavelength was 700 nm. The excitation source is a traditional OPO pumped by a Q-switched Nd:YAG laser with doubler. Photoacoustic images were reconstructed using signals from a small, scanned PVDF transducer acting as an acoustic array. Two different illumination schemes were compared: one was 15 mm x 10 mm in cross section and acted as the broad beam; the other was 5 mm x 2 mm in cross section (15 times smaller than the broad beam case) and was scanned over an area equivalent to broad beam illumination

  16. Developing beam phasing on the Nova laser

    SciTech Connect

    Ehrlich, R.B.; Amendt, P.A.; Dixit, S.N.; Hammel, B.A.; Kalantar, D.H.; Pennington, D.M.; Weiland, T.L.

    1997-03-10

    We are presently adding the capability to irradiate indirectly-driven Nova targets with two rings of illumination inside each end of the hohlraum for studies of time-dependent second Legendre (P2) and time- integrated fourth Legendre (P4) flux asymmetry control. The rings will be formed with specially designed kinoform phase plates (KPPs), which will direct each half of each beam into two separate rings that are nearly uniform azimuthally. The timing and temporal pulse shape of the outer rings will be controlled independently from those of the inner rings, allowing for phasing of the pulse shapes to control time dependent asymmetry. Modifications to the incident beam diagnostics (IBDS) will enable us to verify that acceptable levels of power balance among the contributing segments of each ring have been achieved on each shot. Current techniques for precision beam pointing and timing are expected to be sufficiently accurate for these experiments. We present a design for an affordable retrofit to achieve beam phasing on Nova, results of a simplified demonstration, and calculations highlighting the anticipated benefits.

  17. Designing of the low energy beam lines with achromatic condition in the RAON accelerator

    NASA Astrophysics Data System (ADS)

    Jin, Hyunchang; Jang, Ji-Ho; Jeon, Dong-O.

    2017-01-01

    The RAON accelerator has been built to create and accelerate stable heavy-ion beams and rare isotope beams. The stable heavy-ion beams are generated by the superconducting electron cyclotron resonance ion source and accelerated by the low energy superconducting linac SCL1. The beams accelerated by the SCL1 are re-accelerated by the high energy superconducting linac SCL2 for the generation of rare isotope beams by using the in-flight fragmentation system or are put to use in the low energy experimental halls, which include the neutron science facility and the KOrea Broad acceptance Recoil spectrometer and Apparatus after having passed through the low energy beam lines which have long deflecting sections. At the end of each beam line in the low energy experimental halls, the beams should meet the targets of the two facilities with the specific requirements satisfied. Namely, if the beam is to be sent safely and accurately to the targets and simultaneously, satisfy the requirements, an achromatic lattice design needs to be applied in each beam line. In this paper, we will present the lattice design of the low energy beam lines and describe the results of the beam dynamics simulations. In addition, the correction of the beam orbit, which is distorted by machine imperfections, will be discussed.

  18. Space Charge Correction on Emittance Measurement of Low Energy Electron Beams

    SciTech Connect

    Treado, Colleen J.; /Massachusetts U., Amherst

    2012-09-07

    The goal of any particle accelerator is to optimize the transport of a charged particle beam along a set path by confining the beam to a small region close to the design trajectory and directing it accurately along the beamline. To do so in the simplest fashion, accelerators use a system of magnets that exert approximately linear electromagnetic forces on the charged beam. These electromagnets bend the beam along the desired path, in the case of bending magnets, and constrain the beam to the desired area through alternating focusing and defocusing effects, in the case of quadrupole magnets. We can model the transport of such a beam through transfer matrices representing the actions of the various beamline elements. However, space charge effects, produced from self electric fields within the beam, defocus the beam and must be accounted for in the calculation of beam emittance. We present below the preliminary results of a MATLAB code built to model the transport of a charged particle beam through an accelerator and measure the emittance under the influence of space charge effects. We demonstrate the method of correctly calculating the emittance of a beam under space charge effects using a least square fit to determine the initial properties of the beam given the beam size measured at a specific point after transport.

  19. Test beams and polarized fixed target beams at the NLC

    NASA Astrophysics Data System (ADS)

    Keller, Lewis; Pitthan, Rainer; Rokni, Sayed; Thompson, Kathleen; Kolomensky, Yury

    2001-07-01

    A conceptual program to use NLC beams for test beams and fixed target physics is described. Primary undisrupted polarized beams would be the most simple to use, but for NLC, the disrupted beams are of good enough quality that they could also be used, after collimation of the low energy tails, for test beams and fixed target physics. Pertinent issues are: what is the compelling physics, what are the requirements on beams and running time, and what is the impact on colliding beam physics running. A list of physics topics is given; one topic (Mo/ller Scattering) is treated in more depth.

  20. SPIDER beam dump as diagnostic of the particle beam

    NASA Astrophysics Data System (ADS)

    Zaupa, M.; Dalla Palma, M.; Sartori, E.; Brombin, M.; Pasqualotto, R.

    2016-11-01

    The beam power produced by the negative ion source for the production of ion of deuterium extracted from RF plasma is mainly absorbed by the beam dump component which has been designed also for measuring the temperatures on the dumping panels for beam diagnostics. A finite element code has been developed to characterize, by thermo-hydraulic analysis, the sensitivity of the beam dump to the different beam parameters. The results prove the capability of diagnosing the beam divergence and the horizontal misalignment, while the entity of the halo fraction appears hardly detectable without considering the other foreseen diagnostics like tomography and beam emission spectroscopy.