  1. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    PubMed Central

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-01-01

    Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150

  2. The Divergence of Wear Propagation and Stress at Steep Acetabular Cup Positions Using Ceramic Heads and Sequentially Cross-Linked Polyethylene Liners.

    PubMed

    Zietz, Carmen; Fabry, Christian; Baum, Felix; Bader, Rainer; Kluess, Daniel

    2015-08-01

    The aim of the present wear simulator study was to assess the effect of steep acetabular cup positions on the wear propagation of highly cross-linked-PE (HX-PE) liners. Furthermore, a finite element analysis (FEA) was performed in order to calculate the stress within the HX-PE material in case of steep cup positions under physiological loadings. The higher stress in the HX-PE at a steep acetabular cup position did not result in increased wear in the present wear simulator study. The gravimetrical wear rates at normal (45°) and steep cup inclinations (75°) showed wear amounts of 3.15±0.27mg and 2.18±0.31mg per million cycles (p=0.028), respectively. However, FEA revealed clear increase in stress at the HX-PE liners with respect to steep cup positions.

  3. The importance of acetabular component position in total hip arthroplasty.

    PubMed

    Daines, Brian K; Dennis, Douglas A

    2012-11-01

    Correct acetabular cup position is critical to successful total hip replacement. Unfortunately, malposition of acetabular cups is common and leads to increased rates of dislocation, wear, and ion toxicity. Despite the popularity of Lewinnek's safe zone, the exact target of acetabular abduction and version remains elusive. Differences in functional pelvic position, surgical approach, and femoral anteversion affect the optimal cup position for individual patients. Surgeons need to be aware of pelvic position changes from the supine to lateral decubitus position.

  4. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups.

    PubMed

    Smith, S L; Ash, H E; Unsworth, A

    2000-01-01

    A novel design of polyurethane compliant layer acetabular cup has been developed through a series of friction, creep and wear tests. Friction tests were initially conducted on ABG standard form, polyurethane acetabular cups and an ABG standard form, UHMWPE acetabular cup for comparison. The polyurethane cups showed lower friction than the UHMWPE cup with maximum friction factors between 0. 008 and 0.02 compared with 0.035 for the UHMWPE cup. This indicated that, in the polyurethane cups, more of the load across the joint was carried by the fluid entrapped in the joint space rather than with asperity contact, compared with the UHMWPE cup. The inherent compliance of the polyurethane is used to promote elasto-hydrodynamic lubrication. However, this compliance raised concerns over excessive creep, which may in turn adversely affect tribological performance. Therefore, creep tests were undertaken on the ABG standard form, polyurethane acetabular cups followed by further friction tests. Small amounts of creep occurred in the polyurethane cups at ambient temperature, which reduced the friction slightly (maximum friction factors of 0.009) due to increased conformity between the head and the cup. However, at 37 degrees C, greater creep occurred causing pinching of the femoral head by the acetabular cup resulting in lubricant starvation and higher friction (maximum friction factors of 0.035). The design of the polyurethane cups was subsequently modified to incorporate a flared rim to eliminate the possibility of fluid starvation through pinching. Creep in polyurethane acetabular cups is also affected by the method of fixation of the cups, due to the conformity with and the stiffness of the cup backing. Hence, a one-million-cycle wear test was performed on five ABG flared form, polyurethane acetabular cups on the Mk. I Durham Hip Joint Wear Simulator to evaluate the best method of fixation for the polyurethane cups. The smallest amount of penetration, due to creep and wear

  5. [Ceramic acetabular cups for hip endoprostheses. 7: How do position of the center of rotation and the CCD angle of the shaft modify range of motion and impingement?].

    PubMed

    Bader, R; Willmann, G

    1999-12-01

    The range of motion (ROM) of total hip prostheses is influenced by a number of parameters. An insufficient ROM may cause impingement, which may result in subluxation, dislocation or material failure of the prostheses. In a three-dimensional CAD simulation, the position of the centre of rotation and the CCD angle of the stem were investigated. Displacement of the centre of rotation of the femoral head may be due to wear (PE cups) or to the design of the prosthesis (ceramic cups). Stems of widely differing design have been developed and implanted. The results of the present study demonstrate that the ROM is clearly reduced by increasing penetration of the femoral head. At an inclination angle of 45 degrees, a depth of penetration of 2 mm restricts flexion by about 15 degrees, and a depth of penetration of 3 mm by about 30 degrees. At smaller angles of inclination the ROM is reduced and flexion and abduction are associated with an increased risk of impingement. With steeper acetabular cup inclinations, the risk of impingement decreases, but dislocation, the risk of rim fractures (ceramic cups), and wear and penetration rates (PE cups) increase. The CCD angle of the stem should be oriented to the anatomical situation. At high CCD angles (> 135 degrees), flexion is clearly limited, in particular when there is penetration of the femoral head. For modern total hip arthroplasty, prosthetic systems characterised by precise positioning of components, minimum wear, slightly recessed inserts, and appropriate CCD angles should be used.

  6. Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology.

    PubMed

    Peters, Frank M; Greeff, Richard; Goldstein, Neal; Frey, Chris T

    2012-08-01

    Acetabular cup placement in total hip arthroplasty is often difficult to assess, especially in the lateral position and using the posterior approach. Conventional techniques and computer-assisted surgery are the 2 most popular methods for proper placement of the acetabular cup in Lewinnek's safe zone of orientation (anteversion 15° ± 10° and lateral inclination 40° ± 10°). We developed a system that uses the accelerometer and camera function of the iPhone. A level indicator application and protractor application were downloaded to the iPhone and used to improve acetabular cup placement. This system has proven to be accurate and quick. Our series of 50 prospective cases showed good results with all our acetabular cups being placed within a narrow range in the safe zone and with less than 5% difference between the preoperative, intraoperative, and postoperative acetabular inclinations.

  7. Analysis of version in the acetabular cup.

    PubMed

    Seradge, H; Nagle, K R; Miller, R J

    1982-06-01

    To determine the amount of anteversion or retroversion of the acetabular component of the implanted total hip prosthesis, two anteroposterior radiographs of the hip are obtained, with the contralateral hip flexed to compensate for the possible existing flexion contracture. The X-ray beam is centered on the implanted total hip in one radiograph, and moved away from it toward the contralateral hip in the second radiograph. If the cup is anteverted, the opening will seem wider in the second radiograph. To calculate the angle, the location of the center of the X-ray beam on the X-ray plate must be know. The center of the X-ray beam can be marked on the radiograph by putting a metalic cross on the patient, over the centering cross of the X-ray light source. If the distance of the signature of the X-ray's center beam is less than 8 mm for the center of the cup on the X-ray film, the cup version can be calculated from the arcsin of the shortest to the largest diameter of the cup. If the central ray's signature is farther away, correction is necessary for this calculation. Also, the variable parameters, e.g., cup size, and magnification rate, should be considered in the calculations. The anteroposterior radiographs of the implanted total hip, obtained with the central beam being marked on the X-ray plate, not only are useful for evaluation of the implant but also can be used to calculate the version angle with an accuracy of +/-2 degrees. The necessary calculation is tabulated for cups with an outside diameter of 44-56 mm.

  8. A simplified method to determine acetabular cup anteversion from plain radiographs.

    PubMed

    Widmer, Karl-Heinz

    2004-04-01

    Plain radiographs are the most important diagnostic means for determining the indication and following up on total hip arthroplasty. The acetabular cup position can be easily determined by applying trigonometric functions. This report presents an even simpler method. The short axis of the projected ellipse is measured and related to the total cross-section of the projected cup along the short axis. This relationship correlates with acetabular cup anteversion angles and represents an inverse sinus function. A close linear correlation is seen within the most common interval from 10 degrees to 30 degrees. Anteversion is between 23 degrees to 24 degrees when the ellipse bisects the total acetabular cross-section. This means that simply measuring the length of the short ellipse axis and the total length of the projected cross-section along the short axis provides the radiographic acetabular anteversion. Nonorthogonal projected radiographs should be corrected first.

  9. Comparison of flanged and unflanged acetabular cup design

    PubMed Central

    2010-01-01

    Background and purpose Adequate depth of cement penetration and cement mantle thickness is important for the durability of cemented cups. A flanged cup, as opposed to unflanged, has been suggested to give a more uniform cement mantle and superior cement pressurization, thus improving the depth of cement penetration. This hypothesis was tested experimentally. Materials and methods The same cup design with and without flange (both without cement spacers) was investigated regarding intraacetabular pressure, cement mantle thickness, and depth of cement penetration. With machine control, the cups were inserted into open-pore ceramic acetabular models (10 flanged, 10 unflanged) and into paired cadaver acetabuli (10 flanged, 10 unflanged) with prior pressurization of the cement. Results No differences in intraacetabular pressures during cup insertion were found, but unflanged cups tended to migrate more towards the acetabular pole. Flanged cups resulted in thicker cement mantles because of less bottoming out, whereas no differences in cement penetration into the bone were observed. Interpretation Flanged cups do not generate higher cementation pressure or better cement penetration than unflanged cups. A possible advantage of the flange, however, may be to protect the cup from bottoming out, and there is possibly better closure of the periphery around the cup, sealing off the cement-bone interface. PMID:20860522

  10. Navigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty

    PubMed Central

    Yoon, Jung-Ro; Yu, Jung Jin; Seo, Hyo-Sung

    2014-01-01

    Purpose To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. Materials and Methods This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation and radiographic data to determine whether the acetabular cup was located within the safe zone or not. To evaluate the clinical outcomes, preoperative and last follow-up Harris hip scores were checked, and the occurrence of complications was evaluated. Results According to the navigation data, the mean inclination and anteversion were 38.5°±4.7°(range, 32°-50°) and 16.6°±4.0°(range, 8°-23°), respectively. According to the radiographic data the mean inclination and anteversion were 40.5°±4.6°(range, 32°-50°) and 19.4°±4.2°(range, 8°-25°), respectively. In both cases, all values were within the safe zone. Harris hip score was improved in all patients from preoperative 52.3±14.4 points (range, 29-87 points) to 88.0±9.0 points (range, 65-99 points) at the last follow-up. There was no dislocation or loosening of both cases. Conclusion Navigated acetabular cup fixation is a useful technique for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty because it prevents the malposition and related complications. PMID:27536573

  11. A novel method to assess primary stability of press-fit acetabular cups.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2014-11-01

    Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stability using a novel method for measuring acetabular cup micromotion. A press-fit cup was inserted into Sawbones(®) foam blocks having different densities to simulate normal and osteoporotic bone variations and different acetabular geometries. The stability of the cup was assessed in two ways: (a) measurement of micromotion of the cup in 6 degrees of freedom under physiological loading and (b) uniaxial push-out tests. The results indicate that changes in bone substrate density and acetabular geometry affect the stability of press-fit acetabular cups. They also suggest that cups implanted into weaker, for example, osteoporotic, bone are subjected to higher levels of micromotion and are therefore more prone to loosening. The decrease in stability of the cup in the physiological model suggests that using simplified spherical cavities to model the acetabulum over-estimates the initial stability of press-fit cups. This novel testing method should provide the basis for a more representative protocol for future pre-clinical evaluation of new acetabular cup designs.

  12. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant.

    PubMed

    Bigsby, R J; Hardaker, C S; Fisher, J

    1997-01-01

    The Leeds physiological anatomical (PA) hip joint simulator was developed to apply three axes of loading and a complex three-dimensional motion so that the forces and motions can reproduce exactly the walking cycles defined by Paul. This paper presents the results of a study using the Leeds PA hip joint simulator to determine the wear of 32 mm ultra-high molecular weight polyethylene (UHMWPE) acetabular cups against stainless steel and zirconia ceramic heads, using bovine serum as lubricant. These results have been compared with the results of a previous study that used water as the lubricant, which led to UHMWPE transfer film being formed on the stainless steel head. Comparisons are also made with clinical results and results from other simulators. The study indicates that it is preferable to use bovine serum in simulator studies. In addition, the results indicate that if the surface roughness of the metallic and femoral heads are similar, and they remain undamaged during the tests, the wear rates of the UHMWPE cups are likely to be similar.

  13. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  14. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    PubMed

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  15. Cavitary acetabular defects treated with morselized cancellous bone graft and cementless cups

    PubMed Central

    Pereira, G. C.T.; Kubiak, E. N.; Levine, B.; Chen, F. S.

    2006-01-01

    The use of impacted morselized cancellous bone grafts in conjunction with cementless hemispherical acetabular cups for treatment of AAOS type II acetabular cavitary deficiencies was evaluated in a retrospective study of 23 primary and 24 revision total hip arthroplasties, at a mean follow-up of 7.9 and 8.1 years, respectively. All primary hips received autografts, while all revision hips received allografts. Modified Harris Hip Scores for primary and revision hip replacements increased from a pre-operative mean of 37 and 47 to a postoperative mean of 90 and 86, respectively. All 23 autografts and 23 out of 24 cancellous allografts were radiographically incorporated without evidence of resorption. There were no instances of infection, component migration, or cases requiring subsequent acetabular revision. We conclude that impacted morselized cancellous bone-graft augmentation of cementless cups is a viable surgical option for AAOS type II cavitary acetabular defects. PMID:16988799

  16. Trabecular metal cup without augments for acetabular revision in case of extensive bone loss and low bone-prosthesis contact.

    PubMed

    Pierannunzii, L; Mambretti, A; D'Imporzano, M

    2011-01-01

    Current evidences in revision hip arthroplasty suggest to treat severe acetabular bone loss with dedicated implants, such as anti-protrusio cages, stemmed cups, modular systems supplied with iliac flanges and obturatory hook. However recent literature is reporting satisfactory outcomes with simple elliptical Trabecular Metal cups. Purpose of the study was to evaluate mid-term results of such a surgical procedure. All hip revisions performed from 2008 to 2009 with implantation of a TMT multi-hole acetabular cup without augmentations were retrospectively reviewed. The cases with low-degree acetabular bone loss (stage I and II according to GIR classification), with surgical report poorly describing the bone defect, with inadequate pre- and post-operative x-rays were ruled out. Twenty-five cases were identified, but four were lost to follow-up. The twenty-one patients were 71 year-old on average (from 60 to 82), with stage IV bone loss in 6 cases and stage III bone loss in 15 cases. Mean interval from surgery to evaluation was 20.9 months (from 13 to 30). The evaluation included bone-prosthesis contact estimation, component position, survivorship, complications, final Harris Hip Score, presence of periprosthetic radiolucencies. Host bone-prosthesis contact was estimated to be about 35%. Only three implant were subsequently reoperated (for infection, early migration, recurrent dislocation). The HHS among non-reoperated 18 patients was 81.96 on average (from 63.44 to 95.82). Six cases showed thin radiolucencies in one of the three Charnley zones, while three cases showed radiolucencies in two. None of these images was evolutive, thus they were not considered signs of loosening. The mid-term results of this series confirm the hypothesis that a porous tantalum acetabular cup is an effective option to deal with difficult acetabular revisions. Although no extra-acetabular fixation device is available, the very high surface friction guaranteed by the material and the

  17. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.

    PubMed

    McKellop, H; Shen, F W; DiMaio, W; Lancaster, J G

    1999-12-01

    Crosslinking of ultrahigh molecular weight polyethylene has been shown to markedly improve its wear resistance in clinical studies and laboratory tests using hip joint simulators. However, because most of the laboratory studies have been done under clean conditions using prosthesis-quality, highly polished counterfaces, there is concern regarding how well an intentionally crosslinked polyethylene acetabular cup will resist abrasion by a femoral ball that has been damaged by third-body abrasion in vivo. To investigate this, conventional and radiation crosslinked-remelted acetabular cups of ultra-high molecular weight polyethylene were tested in a hip joint simulator bearing against smooth femoral balls and against balls with moderate and severe roughening. Cups were tested with and without aging to accelerate any oxidative degradation. The crosslinked cups were produced by exposing extruded GUR 4150 bar stock of ultrahigh molecular weight polyethylene to 5 Mrad gamma radiation under a partial vacuum and then the bars were remelted to extinguish residual free radicals. Artificial aging at 70 degrees C under 5 atm oxygen for 14 days induced negligible oxidation in the crosslinked and remelted material. Against smooth balls, the wear of the crosslinked cups, with or without aging, averaged approximately 15% of that of the conventional cups. Against the moderately rough balls, the wear rate of the conventional cups was unchanged, whereas the wear rate increased slightly for the nonaged and aged crosslinked cups, but was still only 26% and 20% of that of the conventional cups, respectively. Against extremely rough balls, the mean wear rates increased markedly for each material such that during the final 1 million cycle interval, the average wear rates of the nonaged and the aged crosslinked cups were 72% and 47% of that of the conventional cups, respectively. That is, the crosslinked polyethylene showed substantially better wear resistance than conventional polyethylene

  18. Revisions of Extensive Acetabular Defects with Impaction Grafting and a Cement Cup

    PubMed Central

    van Egmond, Nienke; De Kam, Daniel C. J.; Gardeniers, Jean W. M.

    2010-01-01

    Background Loosening of acetabular components often leads to bony defects. Management of extensive acetabular bone loss in hip revision arthroplasty can be a tremendous challenge. Questions/purposes We asked whether a reconstruction with impacted bone grafts will provide a durable and pain-free function in extensive acetabular defects. We specifically determined the (1) survival rates with the end point of revision for any reason, aseptic revision, and radiographic loosening; (2) visual analog scale (VAS) pain score, Harris hip score (HHS), and the Oxford Hip Questionnaire score (OHQS); (3) number of repeat revisions; (4) complications; and (5) radiographic loosening, wear, and radiolucencies. Patients and Methods We retrospectively followed 25 patients (27 hips) with extensive acetabular defects. No patient was lost to followup. Two patients died during followup. Minimum followup was 3 years (mean, 8.8 years; range, 3–14.1 years). Results Three patients (three hips) underwent repeat revision surgery and another two patients (two hips) had radiographically loose hips. The 10-year survival rate was 88% (95% confidence interval, 74.2%–100%) with the end point acetabular revision for any reason and 95% (95% confidence interval, 86.0%–100%) with the end point acetabular revision for aseptic loosening. The mean HHSs were 55 points before surgery and 72 points postoperatively. Conclusions Acetabular reconstruction with impaction bone grafting and a cemented cup is a reliable technique with a 10-year survival rate of 88% in patients with extensive acetabular deficiencies. Level of Evidence Level IV, case series. See the Guidelines for Authors for a complete description of levels of evidence. PMID:20931308

  19. Vibrational spectroscopy study of the oxidation of Hylamer UHMWPE explanted acetabular cups sterilized differently

    NASA Astrophysics Data System (ADS)

    Reggiani, Matteo; Tinti, Anna; Visentin, Manuela; Stea, Susanna; Erani, Paolo; Fagnano, Concezio

    2007-05-01

    Ultra-high-molecular-weight polyethylene (UHMWPE) has been used for over 40 years for acetabular cups in total hip joint prosthesis. Hylamer is a hot isostatically pressed material with high crystallinity. Early loosening due to extensive oxidation and phase transformation has been observed for this material. To analyze the reasons for its high tendency to oxidize, we have examined by FT-IR spectroscopy explanted acetabular cups γ-sterilized in different ways. The oxidation and wear rate observed were: Hylamer cups γ-sterilized in air with a long shelf life > Hylamer cups γ-sterilized in air with short shelf life ⩾ Hylamer cups γ-sterilized in nitrogen. Our data indicate the important role of the shelf life on the oxidation of the cups: the samples γ-sterilized in air characterized by a shelf life greater than 3 years showed severe oxidation, a high wear rate, and marked debris production with delamination and the formation of a brittle zone in the more oxidated regions. In these regions we observed an increase in crystallinity, which was probably due to the decrease in the molecular weight of PE. The high oxidation was probably due to the modifications induced by the material treatment.

  20. The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation.

    PubMed

    Dickinson, A S; Taylor, A C; Browne, M

    2012-02-23

    Acetabular cup loosening is a late failure mode of total hip replacements, and peri-prosthetic bone deterioration may promote earlier failure. Preservation of supporting bone quality is a goal for implant design and materials selection, to avoid stress shielding and bone resorption. Advanced polymer composite materials have closer stiffness to bone than metals, ceramics or polymers, and have been hypothesised to promote less adverse bone adaptation. Computer simulations have supported this hypothesis, and the present study aimed to verify this experimentally. A composite hemi-pelvis was implanted with Cobalt Chromium (CoCr), polyethylene (UHMWPE) and MOTIS(®)carbon-fibre-reinforced polyether etherketone (CFR-PEEK) acetabular cups. In each case, load was applied to the implanted pelvis and Digital Image Correlation (DIC) was used for surface strain measurement. The test was repeated for an intact hemi-pelvis. Trends in implanted vs. intact bone principal strains were inspected to assess the average principal strain magnitude change, allowing comparison of the potential bone responses to implantation with the three cups. The CFR-PEEK cup was observed to produce the closest bone strain to the intact hip in the main load path, the superior peri-acetabular cortex (+12% on average, R(2)=0.84), in comparison to CoCr (+40%, R(2)=0.91) and UHWMPE cups (-26%, R(2)=0.94). Clinical observations have indicated that increased periacetabular cortex loading may result in reduced polar cancellous bone loading, leading to longer term losses in periprosthetic bone mineral density. This study provides experimental evidence to verify previous computational studies, indicating that cups produced using materials with stiffness closer to cortical bone recreate physiological cortical bone strains more closely and could, therefore, potentially promote less adverse bone adaptation than stiffer press-fitted implants in current use.

  1. The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation.

    PubMed

    Phillips, A T M; Pankaj; Usmani, A S; Howie, C R

    2004-01-01

    The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup.

  2. Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System.

    PubMed

    Kurosaka, Kenji; Fukunishi, Shigeo; Fukui, Tomokazu; Nishio, Shoji; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Daimon, Takashi; Yoshiya, Shinichi

    2016-07-01

    Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.].

  3. Long-term Radiographic Assessment of Cemented Polyethylene Acetabular Cups

    PubMed Central

    Isaac, Graham; Porter, Neil; Fisher, John; Older, John

    2008-01-01

    In vitro studies demonstrating excessive wear in polyethylene cups sterilized using gamma irradiation and stored in air led to the abandonment of this sterilization technique. We evaluated the clinical wear performance of a metal femoral component on a polyethylene cup in a hip prosthesis from a selected subset of implants in a group of patients followed for at least 20 years and assessed the time dependency of variation in penetration rates. We measured penetration in 33 polyethylene cups in 25 patients who had a Charnley low-friction arthroplasty between 1982 and 1984. All patients had Charnley Ogee® cups implanted for more than 20 years and sterilized using the gamma irradiation in air technique. If degradation occurred over time in vivo, it was not reflected by an increased penetration rate with increasing time in vivo; even after 20 years of implantation, the degree of wear remained low. This suggests gamma irradiation affects wear on ultra-high-molecular-weight polyethylene by reducing wear secondary to the crosslinking, by increasing wear as shown through in vitro studies of heavily oxidized samples, or by oxidation resulting from prolonged shelf life. The effect of progressive oxidation in vivo does not appear to affect wear in vivo. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196419

  4. Effectiveness of an Acetabular Positioning Device in Primary Total Hip Arthroplasty

    PubMed Central

    Hendrix, Stephen L.; Mologne, Timothy S.; Peterson, Drew A.; Holley, Keith A.

    2005-01-01

    To evaluate the efficacy of a commercially available acetabular positioning device, we performed a prospective evaluation of 40 consecutive patients undergoing primary total hip arthroplasty. All surgery was performed by the same surgeon, in the same operating room, and on the same operating table. The acetabular positioning device was designed to place the component in 45° of abduction. At 6 weeks, all radiographs were evaluated by 3 investigators not involved with the surgery. Each radiograph was evaluated by each reviewer on 3 separate occasions, blinded to the findings of the other reviewer to assess interobserver and intraobserver variability. The mean cup abduction angle was 42.1°, with a range from 23° to 57° (SD 8.3°). Intraobserver and interobserver variability were 0.2 and 0.3°, respectively. The findings of this study demonstrate a wide variability in acetabular cup placement in primary total hip arthroplasty. We believe this is due to movement of the pelvis, which may occur during preparation, draping, and retracting during surgery. We feel surgeons should not rely solely on positioning devices when implanting the acetabular component in total hip arthroplasty. Identification of bone landmarks and determination of superolateral implant coverage noted on preoperative templating is advocated to improve the precision of component position. PMID:18751812

  5. What is the Fate of Total Hip Arthroplasty (THA) Acetabular Component Orientation When Evaluated in the Standing Position?

    PubMed

    Tiberi, John V; Antoci, Valentin; Malchau, Henrik; Rubash, Harry E; Freiberg, Andrew A; Kwon, Young-Min

    2015-09-01

    This retrospective study measured the change of the acetabular component orientation between supine and standing radiographs in 113 THA patients and identified the associated anatomical parameters that may help direct pre-operative planning. The mean change of the acetabular component inclination and version from supine to standing was 4.6° and 5.9° respectively (P<0.0001), with 49 (43%) hips showing inclination change >5° and 69 (53%) hips showing version change >5°. Twelve (43%) of 28 'malpositioned' cups became 'well-positioned' and 26 (31%) of 85 'well-positioned' cups became 'malpositioned' upon standing. Changes in inclination were associated with leg length discrepancy and pelvic obliquity; and changes in version were associated with pelvic tilt and pelvic incidence. Standing position and patient factors should be considered when defining "optimal" acetabular orientation.

  6. Effects of screw eccentricity on the initial stability of the acetabular cup in artificial foam bone of different qualities.

    PubMed

    Hsu, Jui-Ting; Lin, Dan-Jae

    2010-01-01

    Acetabular cup loosening is one of the major failure models of total hip replacement (THR), which is mostly due to insufficient initial stability of the cup. Previous studies have demonstrated that cup stability is affected by the quality of the host bone and the surgical skill when inserting screws. The purpose of this study was to determine the effects on the initial stability of the acetabular cup of eccentric screws in bone of different qualities. In this study, hemispherical cups were fixed into bone specimens constructed from artificial foam with three elastic moduli using one to three screws. The effects of two types of screw eccentricity (offset and angular) on the stability of the acetabular cup were also evaluated. The experimental results indicate that in the presence of ideal screwing, the cup was stable in bone specimens constructed from foam with the highest elastic modulus. In addition, increasing the number of ideal screws enhanced the cup stability, especially in bone specimens constructed from soft foam. Moreover, the cup stability was most affected by offset eccentric screw(s) in the hard-foam bone specimens and by angular eccentric screw(s) in the soft-foam bone specimens. The reported results indicate that the presence of screw eccentricity affects the initial stability of the acetabular cup. Surgeons should keep this in mind when performing screw insertions in THR. However, care is necessary when translating these results to the intraoperative situation due to the experiments being conducted under laboratory conditions, and hence, future studies should attempt to replicate the results reported here in vivo.

  7. The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups – finite element simulations and experimental tests

    PubMed Central

    Korhonen, Rami K; Koistinen, Arto; Konttinen, Yrjö T; Santavirta, Seppo S; Lappalainen, Reijo

    2005-01-01

    Background Contact pressure of UHMWPE acetabular cup has been shown to correlate with wear in total hip replacement (THR). The aim of the present study was to test the hypotheses that the cup geometry, abduction angle, thickness and clearance can modify the stresses in cemented polyethylene cups. Methods Acetabular cups with different geometries (Link®: IP and Lubinus eccentric) were tested cyclically in a simulator at 45° and 60° abduction angles. Finite element (FE) meshes were generated and two additional designs were reconstructed to test the effects of the cup clearance and thickness. Contact pressures at cup-head and cup-cement interfaces were calculated as a function of loading force at 45°, 60° and 80° abduction angles. Results At the cup-head interface, IP experienced lower contact pressures than the Lubinus eccentric at low loading forces. However, at higher loading forces, much higher contact pressures were produced on the surface of IP cup. An increase in the abduction angle increased contact pressure in the IP model, but this did not occur to any major extent with the Lubinus eccentric model. At the cup-cement interface, IP experienced lower contact pressures. Increased clearance between cup and head increased contact pressure both at cup-head and cup-cement interfaces, whereas a decreased thickness of polyethylene layer increased contact pressure only at the cup-cement interface. FE results were consistent with experimental tests and acetabular cup deformations. Conclusion FE analyses showed that geometrical design, thickness and abduction angle of the acetabular cup, as well as the clearance between the cup and head do change significantly the mechanical stresses experienced by a cemented UHMWPE acetabular cup. These factors should be taken into account in future development of THR prostheses. FE technique is a useful tool with which to address these issues. PMID:15904521

  8. Ultra high molecular weight polyethylene and polydimethylsiloxane blend as acetabular cup material.

    PubMed

    Khorasani, M T; Zaghiyan, M; Mirzadeh, H

    2005-03-25

    An acetabular cup shock absorber implant is formed from a composite of polymer materials. The cup consists of three zones such as the articulating surface of the implant is 100% ultra high molecular weight polyethylene (UHMWPE) (zone 1) and shock absorber of the cup contains of polydimethylsiloxane (PDMS) (zone 3). Zone 2 which is designed for better adhesion between zone 1 and zone 2 consists of a blend of UHMWPE and PDMS is a cushion that from one side adheres to zone 1 and the other side to zone 2. PDMS and UHMWPE have been blended under conditions of shear and elevated temperature in order to form uniform, thermoplastic blends. When blends compared to pure UHMWPE, the blends show lowered tensile modulus and lowered mixing energies. The UHMWPE crystals are increased in quantity or else become more regular, even 50% blend shows no rubbery stage. The morphology and dynamic mechanical behavior of the blends were studied using scanning electron microscopy (SEM) and dynamic mechanic thermal analysis (DMTA). In this study, the biocompatibility have evaluated in vitro the interaction of UHMWPE, silicone and PDMS/UHMWPE blends with L929 fibroblast cells.

  9. Al-Cu-Fe quasicrystal/ultra-high molecular weight polyethylene composites as biomaterials for acetabular cup prosthetics.

    PubMed

    Anderson, Brian C; Bloom, Paul D; Baikerikar, K G; Sheares, Valerie V; Mallapragada, Surya K

    2002-04-01

    Polymer composites of Al-Cu-Fe quasicrystals and ultra-high molecular weight polyethylene (UHMWPE) were investigated for use in acetabular cup prosthetics. The wear properties of the Al-Cu-Fe/UHMWPE samples and a 440 steel ball counterface were measured. The mechanical strength of the Al-Cu-Fe/UHMWPE composites was compared to UHMWPE and alumina/UHMWPE. The biocompatibility of the composite material was tested using a direct contact cytotoxicity assay. Al-Cu-Fe/UHMWPE demonstrated lower volume loss after wear and higher mechanical strength than UHMWPE. This composite material also showed no increase in counterface wear or cytotoxicity relative to UHMWPE. These combined results demonstrate that Al-Cu-Fe/UHMWPE composites are promising candidate materials for acetabular cup prosthetics.

  10. The use of a "rim cutter" device and a flanged cup for improving the mantle of the acetabular component of a cemented Exeter total hip arthroplasty.

    PubMed

    Fernández-Valencia, Jenaro Ángel; Gallart, Xavier; Bori, Guillem; Rodríguez-Roiz, Juan Miguel; Combalia, Andreu

    2016-12-01

    A retrospective study was performed to evaluate the cement mantle in two groups of patients treated with the acetabular components of cemented Exeter total hip arthroplasties (THAs). Two groups of 20 patients were compared: Group 1 received non-flanged acetabular cemented cups (Contemporary, Stryker) and Group 2 received flanged acetabular cemented cups (X3 Rim Fit, Stryker). Cups in Group 2 were implanted after using a rim cutter device. Group 2 showed better penetration of cement in zone 1 (10.76 mm compared with 2.93 mm; p = 0.008) and a thicker cement mantle in zone 1 (3.57 mm compared with 2.89 mm; p = 0.04). More cups in Group 2 had a cement mantle thickness less than 3 mm (30 % in Group 1 compared with 70 % in Group 2; p = 0.0039). No other radiological differences were observed. These results favor the use of a rim cutter device and flanged cup to improve the cement mantle for the acetabular components of cemented Exeter THAs. However, the improvements were less than expected. In view of the results of previous studies, further research is therefore needed to assess the value of this approach in improving the acetabular cement mantle.

  11. Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study

    PubMed Central

    Michel, Adrien; Bosc, Romain; Meningaud, Jean-Paul; Hernigou, Philippe; Haiat, Guillaume

    2016-01-01

    Background The primary stability of the acetabular cup (AC) implant is an important determinant for the long term success of cementless hip surgery. However, it remains difficult to assess the AC implant stability due to the complex nature of the bone-implant interface. A compromise should be found when inserting the AC implant in order to obtain a sufficient implant stability without risking bone fracture. The aim of this study is to evaluate the potential of impact signals analyses to assess the primary stability of AC implants inserted in cadaveric specimens. Methods AC implants with various sizes were inserted in 12 cadaveric hips following the same protocol as the one employed in the clinic, leading to 86 different configurations. A hammer instrumented with a piezoelectric force sensor was then used to measure the variation of the force as a function of time produced during the impact between the hammer and the ancillary. Then, an indicator I was determined for each impact based on the impact momentum. For each configuration, twelve impacts were realized with the hammer, the value of the maximum amplitude being comprised between 2500 and 4500 N, which allows to determine an averaged value IM of the indicator for each configuration. The pull-out force F was measured using a tangential pull-out biomechanical test. Results A significant correlation (R2 = 0.69) was found between IM and F when pooling all data, which indicates that information related to the AC implant biomechanical stability can be retrieved from the analysis of impact signals obtained in cadavers. Conclusion These results open new paths in the development of a medical device that could be used in the future in the operative room to help orthopedic surgeons adapt the surgical protocol in a patient specific manner. PMID:27893757

  12. [Evaluation of acetabular cup placement precision in Stryker computer-assisted navigated total hip arthroplasty].

    PubMed

    Shang, Peng; Bai, Xueling; Shi, Dufang

    2012-09-01

    To contrast the methodology of measuring cup placement precision utilizing Mimics and Matlab programming, based on clinical CT images of primary THA cases with computer assisted navigated surgery (CANS) and with the traditional manual method (MANS). The method was applied and analyzed to measure cup anteversion, cup abduction of 50 clinical cases with CANS and MANSThe results show that, cup placement precision differences exits between primary THA cases with CANS and MANS; more cases with CANS are within the safe zone contrasting MANS, and there was less variation and less placement error in CANS cases. CANS can improve cup placement precision and reduce the chance of dislocation efficiently.

  13. Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator.

    PubMed

    Taddei, Paola; Affatato, Saverio; Fagnano, Concezio; Toni, Aldo

    2006-06-01

    This study was aimed at comparing the oxidative degradation of commercial acetabular cups made of cross-linked polyethylene (XLPE) and conventional ultrahigh molecular weight polyethylene (UHMWPE). After testing against deliberately scratched CoCrMo femoral heads in a hip joint simulator, the cups, microtomed parallel to the articulating surface, were analyzed by IR spectroscopy. Due to the potential for artifacts caused by absorbed contaminants, the IR spectra were compared only after hexane extraction; actually, XLPE was found to absorb more serum than UHMWPE. The two sets of unworn acetabular cups showed different oxidation patterns with consequently different distributions of carbonyl species; unworn XLPE was characterized by lower contents of carbonyl species and hydrogen-bonded alcohols and higher contents of trans-vinylene species than unworn UHMWPE. Upon simulator testing, UHMWPE showed more significant changes in oxidation indexes and distribution of carbonyl compounds than XLPE, confirming a better wear behavior for XLPE under the adopted testing conditions.

  14. Cementless acetabular revision arthroplasty

    PubMed Central

    Jain, Rina; Schemitsch, Emil H.; Waddell, James P.

    2000-01-01

    Objective To evaluate the effects of clinical factors on outcome after acetabular revision with a cementless beaded cup. Design Retrospective case series. Setting Tertiary care referral centre. Patients Forty-one patients who underwent acetabular revision with a cementless cup were followed up for a mean of 3.4 years. Interventions Acetabular revision with a beaded cementless cup in all patients. A morcellized allograft was used in 10 patients. Outcome measures A modified Harris hip score (range of motion measurement omitted), the SF-36 health survey, and the Western Ontario McMaster (WOMAC) osteoarthritis index. Multivariate analysis was used to evaluate the effects of age, gender, morcellized allografting, time to revision from the previous operation, acetabular screw fixation and concurrent femoral revision on outcome. Results Gender accounted for a significant portion of the variation seen in the SF-36 physical component scores (r = 0.36, p = 0.02), with women tending to have worse results. Increasing age was associated with lower WOMAC index function scores (r = 0.36, p = 0.03), whereas concurrent femoral revision tended to have a positive effect on WOMAC index function (r = 0.39, p = 0.01). None of the potential clinical predictors had any significant effect on the SF-36 mental component scores, or WOMAC index pain and stiffness scores. Conclusions In cementless acetabular revision arthroplasty, physical function, as measured by generic and limb-specific scales, may be affected by gender, age and the presence of a concurrent femoral revision. Time to revision from the previous operation, morcellized allografting and screw fixation of the acetabulum did not affect outcomes. This information may provide some prognostic value for patients’ expectations. PMID:10948687

  15. Structural profile of ultra-high molecular weight polyethylene in acetabular cups worn on hip simulators characterized by confocal Raman spectroscopy.

    PubMed

    Puppulin, Leonardo; Kumakura, Tsuyoshi; Yamamoto, Kengo; Pezzotti, Giuseppe

    2011-06-01

    We applied a Raman confocal spectroscopic technique to quantitatively assess the structural features of two kinds of acetabular cups made of ultra-high molecular weight polyethylene. We wanted to know whether polyethylene cups belonging to different generations, and thus manufactured by different procedures, possess different molecular structures and how those differences affected their wear resistance. Emphasis was placed on oxidation profiles developed along the cross-sectional depth of the cups in the main wear zone developed during testing in a hip simulator. The micrometric lateral resolution of the laser beam, focused at surface or sub-surface sectional planes, enabled the visualization of highly resolved microstructural property profiles, including crystalline and amorphous phase fractions. Oxidation profiles retrieved from polyethylene cups belonging to different generations greatly differed after wear testing. The highly cross-linked polyethylene showed a lower degree of crystallinity and oxidation at an appreciably slower rate as compared to that belonging to an earlier generation.

  16. Importance of maintaining the basic stress pathway above the acetabular dome during acetabular reconstruction.

    PubMed

    Nie, Yong; Pei, Fuxing; Shen, Bin; Kang, Pengde; Li, Zongming

    2016-01-01

    The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in press-fit acetabular reconstruction of total hip arthroplasty. However, information on the basic stress pathway and its impact factors remains unclear. The objective of this study was to investigate the effects of the orientations and positions of the acetabular component on the basic stress pathway. The basic stress pathway above the acetabular dome was defined as two parts: 3D basic trabecular bone stress distribution and quantified basic cortical bone stress level, using two subject-specific finite element normal hip models. The effects were then analysed by generating 32 reconstructed acetabular cases with different cup abduction and anteversion angles within a range of 35-50° and 10-25°, respectively, and 12 cases with different hip centre heights within a range of 0-15 mm above the acetabular dome. The 3D trabecular stress distribution decreased remarkably in all cases, while the 80% of the basic cortical bone stress level was maintained in cases when the acetabular component was positioned at 10° or 15° anteversion and 40° or 45° abduction angles. The basic stress pathway above the acetabular dome was disturbed when the superior displacement of the hip centre exceeded 5 mm above the anatomical hip centre. Positioning the acetabular component correctly contributes to maintain the stress balance between the acetabular cup and the bone during acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants.

  17. Comparison of Head Center Position and Screw Fixation Options Between a Jumbo Cup and an Offset Center of Rotation Cup in Revision Total Hip Arthroplasty: A Computer Simulation Study.

    PubMed

    Faizan, Ahmad; Black, Brandon J; Fay, Brian D; Heffernan, Christopher D; Ries, Michael D

    2016-01-01

    Jumbo acetabular cups are commonly used in revision total hip arthroplasty (THA). A straightforward reaming technique is used which is similar to primary THA. However, jumbo cups may also be associated with hip center elevation, limited screw fixation options, and anterior soft tissue impingement. A partially truncated hemispherical shell was designed with an offset center of rotation, thick superior rim, and beveled anterior and superior rims as an alternative to a conventional jumbo cup. A three dimensional computer simulation was used to assess head center position and safe screw trajectories. Results of this in vitro study indicate that a modified hemispherical implant geometry can reduce head center elevation while permitting favorable screw fixation trajectories into the pelvis in comparison to a conventional jumbo cup.

  18. Radiostereometric Analysis Study of Tantalum Compared with Titanium Acetabular Cups and Highly Cross-Linked Compared with Conventional Liners in Young Patients Undergoing Total Hip Replacement

    PubMed Central

    Ayers, David C.; Greene, Meridith; Snyder, Benjamin; Aubin, Michelle; Drew, Jacob; Bragdon, Charles

    2015-01-01

    Background: Radiostereometric analysis provides highly precise measurements of component micromotion relative to the bone that is otherwise undetectable by routine radiographs. This study compared, at a minimum of five years following surgery, the micromotion of tantalum and titanium acetabular cups and femoral head penetration in highly cross-linked polyethylene liners and conventional (ultra-high molecular weight polyethylene) liners in active patients who had undergone total hip replacement. Methods: This institutional review board-approved prospective, randomized, blinded study involved forty-six patients. Patients were randomized into one of four cohorts according to both acetabular cup and polyethylene liner. Patients received either a cementless cup with a titanium mesh surface or a tantalum trabecular surface and either a highly cross-linked polyethylene liner or an ultra-high molecular weight polyethylene liner. Radiostereometric analysis examinations and Short Form-36 Physical Component Summary, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), University of California Los Angeles (UCLA) activity, and Harris hip scores were obtained preoperatively, postoperatively, at six months, and annually thereafter. Results: All patients had significant improvement (p < 0.05) in Short Form-36 Physical Component Summary, WOMAC, UCLA activity, and Harris hip scores postoperatively. On radiostereometric analysis examination, highly cross-linked polyethylene liners showed significantly less median femoral head penetration at five years (p < 0.05). Steady-state wear rates from one year to five years were 0.04 mm per year for ultra-high molecular weight polyethylene liners and 0.004 mm per year for highly cross-linked polyethylene liners. At the five-year follow-up, the median migration (and standard error) was 0.05 ± 0.20 mm proximally for titanium cups and 0.21 ± 0.05 mm for tantalum cups. Conclusions: In this young population who had undergone

  19. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head.

    PubMed

    Scholes, S C; Inman, I A; Unsworth, A; Jones, E

    2008-04-01

    New material combinations have been introduced as the bearing surfaces of hip prostheses in an attempt to prolong their life by overcoming the problems of failure due to wear-particle-induced osteolysis. This will hopefully reduce the need for revision surgery. The study detailed here used a hip simulator to assess the volumetric wear rates of large-diameter carbon-fibre-reinforced pitch-based poly(ether-ether-ketone) (CFR-PEEK) acetabular cups articulating against alumina femoral heads. The joints were tested for 25 x 10(6) cycles. Friction tests were also performed on these joints to determine the lubrication regime under which they operate. The average volumetric wear rate of the CFR-PEEK acetabular component of 54 mm diameter was 1.16 mm(3)/10(6) cycles, compared with 38.6 mm(3)/10(6) cycles for an ultra-high-molecular-weight polyethylene acetabular component of 28 mm diameter worn against a ceramic head. This extremely low wear rate was sustained over 25 x 10(6) cycles (the equivalent of up to approximately 25 years in vivo). The frictional studies showed that the joints worked under the mixed-boundary lubrication regime. The low wear produced by these joints showed that this novel joint couple offers low wear rates and therefore may be an alternative material choice for the reduction of osteolysis.

  20. Works in progress #7. Clinical experience with the Accu-Path threaded acetabular cup. A preliminary report.

    PubMed

    Harwin, S F; Stern, R E; Kulick, R G

    1991-10-01

    Clinical experience with the Accu-Path threaded titanium hemispheric cup is presented. A series of 62 cases was followed for an average of 28.1 months (range, 6 to 48). Primary surgery was performed in 50 cases and revision surgery in 12. The surgical technique is described in detail. Preoperative Harris scores improved from 28 to 93 in primary cases and from 24 to 84 in revision cases. Complications included 3.2% dislocation, 3.2% loss of cup position, and 1.6% recurrent subluxation. The overall reoperation rate was 8% (8% in primary surgery and 8.3% in revision surgery). Roentgenographic analysis is discussed. The importance of preservation of the subchondral plate and a rim fit in the use of this implant is stressed. It is not indicated in those with loss of the plate due either to prior surgery (as in revision) or in aggressive over-reaming in primary cases. Although the overall results were encouraging, caution was recommended--especially in revision surgery or in the patient with severe osteopenia.

  1. Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup.

    PubMed

    Eddine, T A; Migaud, H; Chantelot, C; Cotten, A; Fontaine, C; Duquennoy, A

    2001-01-01

    The position of the acetabular implant plays a dominant role in the displacement of a total hip prosthesis. CT allows precise measurement of the position of the cup, but the influence of pelvic rotation on this measurement is unknown. The aim of this study was to determine, in a group of healthy subjects, whether a pelvic equilibrium exists specific to each individual, and whether this is constant over time on the one hand and between the standing and lying positions on the other. The study concerned 15 men and 9 women with a mean age of 31 years. Each subject had strictly lateral radiographs of the pelvis, lying and standing, repeated at two different times. Pelvic version was measured in these radiographs. Each individual had a pelvic position constant over time, both in the lying and standing positions. However, there were important variations of the position of the pelvis during passage from the lying to the standing position: 22 patients had retroversion of the pelvis by a mean of 7 degrees (2-18 degrees) and 2 others had an anteversion of 3 degrees. These major variations of the pelvic position between the standing and lying positions explain why CT studies made in the lying position do not allow for the anteversion of the cup in the standing position, which is close to the dynamic situation during which displacement may occur. Thus, an excessive anteversion of the cup may be masked when the scan is made in the lying position, since in this position the anteversion of the pelvis leads to retroversion of the cup. The error may reach 20 degrees, so that we recommend that CT measurements made without allowing for the position of the pelvis should be interpreted with caution.

  2. The effects of irradiation and EtO-treatment on ultrahigh molecular weight polyethylene acetabular cups following accelerated aging: Degradation of mechanical properties and morphology changes during hip simulator tests

    NASA Astrophysics Data System (ADS)

    Taddei, Paola; Affatato, Saverio; Rocchi, Mirko; Fagnano, Concezio; Viceconti, Marco

    2008-03-01

    The present study was aimed at investigating the effects of the sterilization method and accelerated aging on the wear and morphology of ultrahigh molecular weight polyethylene. In a first test, gamma- and EtO-sterilized acetabular cups were tested in a hip joint simulator for two million cycles. After the test, the cups underwent an accelerated aging treatment (80 °C, 4 weeks in air furnace) and were newly tested for another three million cycles. Wear was evaluated by gravimetric measurements, morphology by micro-Raman spectroscopy. During the first test, the EtO-sterilized cups underwent a significantly higher wear than the gamma-sterilized ones (62 and 30 mg/million cycles, respectively). No significant crystallinity changes were observed. Upon accelerated aging, the crystallinity increase of the gamma-sterilized cups was more pronounced than for the EtO-sterilized cups, due to chain scission and oxygen incorporation. In the second test, the wear rate of EtO-sterilized cups decreased to 38 mg/million cycles, while for gamma-irradiated cups it increased to 84 mg/million cycles. At the same time, the latter cups underwent significant increases in temperature and crystallinity, due to the higher friction. For the EtO-sterilized cups a significant decrease in crystallinity was observed, due to the occurrence of an orthorhombic → monoclinic phase transformation.

  3. Management of neglected acetabular fractures.

    PubMed

    Veerappa, L A; Tripathy, S K; Sen, R K

    2015-08-01

    Management of neglected acetabular fractures is a difficult task. Osteosynthesis in such cases may not be an ideal solution because of the femoral head damage due to pressure by the fractured acetabular edge, avascular necrosis, difficulty in mobilizing the fragments due to callus formation, difficulty in indirect reduction of the fracture fragments and macerated acetabular fragments all contributing to inadequate fracture reduction. Majority of such fractures are now treated with total hip replacement. While treating such fractures with THR, problems associated with neglected acetabular fractures such as fracture non-union, hip dislocation, protrusio, cavitary bone defect or peripheral bone defect must be considered. 3D computed tomography scan provides a clear view about the acetabular and periacetabular bony anatomy. Impaction grafting and antiprotrusio cage or ring with a cemented acetabular cup can address most of the hip protrusio and cavitary bone defects. Segmental bone defect needs cortical strut-bone graft fixation and subsequent implantation of a cemented or uncemented acetabular cup implantation. Fracture non-union needs approximate reduction and fixation with plates followed by bone grafting and implantation of an acetabular cup. Despite these efforts, the outcome of THR in neglected acetabular fracture is considerable worse than after conventional hip replacement.

  4. Measuring acetabular component position on lateral radiographs - ischio-lateral method.

    PubMed

    Pulos, Nicholas; Tiberi Iii, John V; Schmalzried, Thomas P

    2011-01-01

    The standard method for the evaluation of arthritis and postoperative assessment of arthroplasty treatment is observation and measurement from plain films, using the flm edge for orientation. A more recent employment of an anatomical landmark, the ischial tuberosity, has come into use as orientation for evaluation and is called the ischio-lateral method. In this study, the use of this method was evaluated as a first report to the literature on acetabular component measurement using a skeletal reference with lateral radiographs. Postoperative radiographs of 52 hips, with at least three true lateral radiographs taken at different time periods, were analyzed. Component position was measured with the historical method (using the flm edge for orientation) and with the new method using the ischio-lateral method. The mean standard deviation (SD) for the historical approach was 3.7° and for the ischio-lateral method, 2.2° (p < 0.001). With the historical method, 19 (36.5%) hips had a SD greater than ± 4°, compared to six hips (11.5%) with the ischio-lateral method. By using a skeletal reference, the ischio-lateral method provides a more consistent measurement of acetabular component position. The high intra-class correlation coefficients for both intra- and inter-observer reliability indicate that the angle measured with this simple method, which employs no further technology, increased time, or cost, is consistent and reproducible for multiple observers.

  5. Acquisition of cup drinking using previously refused foods as positive and negative reinforcement.

    PubMed

    Kelley, Michael E; Piazza, Cathleen C; Fisher, Wayne W; Oberdorff, Amanda J

    2003-01-01

    We used previously refused foods as positive and negative reinforcement in the acquisition of cup drinking. Cup drinking increased with positive and negative reinforcement, both alone and in combination (without escape extinction), indicating that treatment of food refusal can establish some foods as appetitive stimuli whereas others remain aversive.

  6. [Analysis of migration of screwed acetabular components following revision arthroplasty of the hip joint. Results of single-image roentgen analysis].

    PubMed

    Dihlmann, S W; Ochsner, P E; Pfister, A; Mayrhofer, P

    1994-01-01

    Out of 57 revised acetabular components, which were regularly checked, 47 had been replaced by a cemented Müller's acetabular reinforcement ring resp. a cementless Müller's Sl-shell with flange. Both types of cups are anchored in the acetabular roof with cancellous bone screws (tab. 1). 42 cases with radiograph series permitted a detailed analysis with the EBRA-method, a computer aided method for the evaluation of acetabular spatial migration based on standard radiographs of the pelvis. The clinical results were very satisfying (tab. 6). The screwed acetabular components migrated little, although, some essential displacements of the center of rotation (in relation to the anatomical position) had to be accepted. As was recognizable with today's inaccurate methods of measuring the center of the head, the displacement too far towards cranial influenced the migration tendency less than an excessive lateralisation. Especially satisfying is the fact, that no increased migration was observed after reconstruction bone grafting of severe acetabular defects, provided that at least a partly direct contact between the acetabular component and the original bone stock was obtained. For the first time EBRA shall be introduced here as a method which shows the migration and the spatial inclination of the acetabular cup in a vector chart.

  7. Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims

    PubMed Central

    Wada, Hiroshi; Mishima, Hajime; Yoshizawa, Tomohiro; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    Background In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible because of direct palpation using a pointer. Imageless navigation using the ACA usually targets patients with normal acetabular morphology. The aim of this study was to investigate the accuracy of imageless navigation using the ACA instead of the APP in patients with normal or deformed acetabular rims. Methods The intraoperative cup position was compared with that obtained from the postoperative computed tomography (CT) images in 18 cases. Results The inclination angle derived from the navigation system was 3.4 ± 5.3 degrees smaller and the anteversion angle was 1.4 ± 3.1 degrees larger than those derived from the CT images. Conclusion The inclination cup angle of the navigation system was significantly inferior to the true value, particularly in cases with large anterior osteophytes. PMID:27073586

  8. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    PubMed Central

    Nakashima, Yasuharu; Nakamura, Tetsuro; Ito, Yoshihiro; Hara, Toshihiko

    2017-01-01

    Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups) in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months). The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE) angle and the bone coverage index (BCI) from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3%) and the minimum cup-CE angle was −9.2° (BCI: 48.8%). Thin radiolucent lines were observed in 5 hips (2.3%), which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50%) was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%). PMID:28299327

  9. Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis.

    PubMed

    Berthonnaud, E; Hilmi, R; Dimnet, J

    2012-01-01

    The goal of this paper is to access to pelvis position and morphology in standing posture and to determine the relative locations of their articular surfaces. This is obtained from coupling biplanar radiography and bone modeling. The technique involves different successive steps. Punctual landmarks are first reconstructed, in space, from their projected images, identified on two orthogonal standing X-rays. Geometric models, of global pelvis and articular surfaces, are determined from punctual landmarks. The global pelvis is represented as a triangle of summits: the two femoral head centers and the sacral plateau center. The two acetabular cavities are modeled as hemispheres. The anterior sacral plateau edge is represented by an hemi-ellipsis. The modeled articular surfaces are projected on each X-ray. Their optimal location is obtained when the projected contours of their models best fit real outlines identified from landmark images. Linear and angular parameters characterizing the position of global pelvis and articular surfaces are calculated from the corresponding sets of axis. Relative positions of sacral plateau, and acetabular cavities, are then calculated. Two hundred standing pelvis, of subjects and scoliotic patients, have been studied. Examples are presented. They focus upon pelvis orientations, relative positions of articular surfaces, and pelvis asymmetries.

  10. A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial.

    PubMed

    Troelsen, Anders; Greene, Meridith E; Ayers, David C; Bragdon, Charles R; Malchau, Henrik

    2015-12-01

    Conventional radiostereometric analysis (RSA) for wear is not possible in patients with tantalum cups. We propose a novel method for wear analysis in tantalum cups. Wear was assessed by gold standard RSA and the novel method in total hip arthroplasty patients enrolled in a randomized controlled trial receiving either titanium or tantalum cups (n=46). The novel method estimated the center of the head using a model based on identification of two proximal markers on the stem and knowledge of the stem/head configuration. The novel method was able to demonstrate a pattern of wear that was similar to the gold standard in titanium cups. The novel method offered accurate assessment and is a viable solution for assessment of wear in studies with tantalum cups.

  11. Dilemmas in imaging for peri-acetabular osteotomy: the influence of patient position and imaging technique on the radiological features of hip dysplasia.

    PubMed

    Kosuge, D; Cordier, T; Solomon, L B; Howie, D W

    2014-09-01

    Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam.

  12. Transfer of metallic debris from the metal surface of an acetabular cup to artificial femoral heads by scraping: comparison between alumina and cobalt-chrome heads.

    PubMed

    Chang, Chong Bum; Yoo, Jeong Joon; Song, Won Seok; Kim, Deug Joong; Koo, Kyung-Hoi; Kim, Hee Joong

    2008-04-01

    We aimed to investigate the transfer of metal to both ceramic (alumina) and metal (cobalt-chrome) heads that were scraped by a titanium alloy surface under different load conditions. The ceramic and metal heads for total hip arthroplasties were scraped by an acetabular metal shell under various loads using a creep tester. Microstructural changes in the scraped area were visualized with a scanning electron microscope, and chemical element changes were assessed using an energy dispersive X-ray spectrometry. Changes in the roughness of the scraped surface were evaluated by a three-dimensional surface profiling system. Metal transfer to the ceramic and metal heads began to be detectable at a 10 kg load, which could be exerted by one-handed force. The surface roughness values significantly increased with increasing test loads in both heads. When the contact force increased, scratching of the head surface occurred in addition to the transfer of metal. The results documented that metallic debris was transferred from the titanium alloy acetabular shell to both ceramic and metal heads by minor scraping. This study suggests that the greatest possible effort should be made to protect femoral heads, regardless of material, from contact with metallic surfaces during total hip arthroplasty.

  13. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    PubMed Central

    Bollini, Gérard; Legaye, Jean; Tardieu, Christine; Prat-Pradal, Dominique; Chabrol, Brigitte; Jouve, Jean-Luc; Duval-Beaupère, Ginette; Pélissier, Jacques

    2014-01-01

    Acetabular cup orientation (inclination and anteversion) is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter) emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter) could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society) providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter) could determine the safe range of pelvis tilt (positional parameter) for an individual and not a group. PMID:25006461

  14. Optimization of acetabular component orientation using DOE

    NASA Astrophysics Data System (ADS)

    Krepelka, Mircea; Toth-Taşcǎu, Mirela

    2012-09-01

    Stress shielding is increasingly recognized as an important cause of acetabular component failure. Several studies have been focused on improving the acetabular component placement to reduce the risk of dislocation, impingement and range of motion but little is known of its influence on implant-bone interface pressures. This study employs experimental design, 3D reconstruction and FE simulation to identify the most significant factors for acetabular component behavior and predict the best configuration of acetabular spatial orientation angles within the constraints of the Lewinnek's safe zone in order to minimize peak contact pressures. Data analysis by response surface method revealed that the magnitude of periacetabular pressures was significantly reduced by the anteversion angle at its lowest value as well as the abduction angle located at the central point value, which corresponded to a 40° abduction and 5° anteversion of cup orientation.

  15. Analysis of wear of polyethylene hip joint cup related to its positioning in patient's body.

    PubMed

    Rońda, Jacek; Wojnarowski, Paweł

    2013-01-01

    Polyethylene parts of endoprosthesis are the weakest parts of each medical implant. They can be worn out within several years. During this period, a patient can enjoy good physical efficiency until the wear of polyethylene part limits his/her mobility. Then the reoperation is necessary and positioning of all parts of endoprosthesis has an effect on future patient's mobility and durability of implant. Elements of endoprosthesis during exploitation are heavily loaded both by normal and tangential forces and moments. In this paper, the dependence of wear of polyethylene cup on its positioning in pelvis is the major problem. Wear of the cup is determined by two measures: the depth and volume of a material rubbed off from the contact surface. The sensitivity of the depth of rubbing off is evaluated relative to two angles of anteversion and abduction, and radii of the cup. Numerical results are obtained by using Abaqus FE system with data related to patient's activity identified on the basis of medical reports.

  16. Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study

    PubMed Central

    Huang, De-Yong; Zhang, Liang; Zhou, Yi-Xin; Zhang, Chun-Yu; Xu, Hui; Huang, Yong

    2016-01-01

    Background: Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures, and good results have been reported with the use of these cups; however, the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear. This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures. Methods: A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012. Among these patients, two were lost to follow-up. Therefore, 39 patients (39 hips) were finally included in this study. The Harris hip score before and after the surgery, satisfaction level of the patients, and radiographic results were assessed. Results: The mean Harris hip score increased from 34 (range, 8–52) before surgery to 91 (range, 22–100) at the latest follow-up examination (P < 0.001). The results were excellent for 28 hips, good for six, fair for three, and poor for two. Among the 39 patients, 25 (64%) and 10 (26%) were very satisfied and somewhat satisfied, respectively. All cups were found to be fully incorporated, and no evidence of cup migration or periacetabular osteolysis was noted. Conclusions: Despite the technically demanding nature of the procedure, THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures. PMID:27064033

  17. Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature

    PubMed Central

    Figueras, Guillem; Planell, Ramón Vives; Fernàndez, Ramón Serra; Biayna, Joan Camí

    2016-01-01

    Background: As a consequence of use of metal-on-metal hip arthroplasties some patients have precised revision for pain or metal hipersensivity reactions among other causes. We propose to salvage monoblock acetabular component and femoral component using a dual-mobility head and perform a lower morbidity operation in young patients preserving host bone stock in cases with well fixed and positioned components. Objective: (1) What clinical problems have been reported in patients with Metal-on-metal hip arthroplasties? (2) Could the tribocorrosion potentially cause a fracture of neck femoral component? (3) Can be the dual-mobility head a recourse in metal-on-metal hip revision? Methods: Ten patients were revised for pain or/and raised Cobalt/Chromium levels between August 2012 and December 2015. In three cases femoral neck component was fractured and femoral revision was necessary. In four hips, acetabular and femoral components could be maintained. Age, body index mass, ion levels, acetabular position, size of acetabular component and femoral head, approach, blood transfunsion and time of hospitalization were analized. Results: At a mean follow-up of 25,6 months (6 to 45) the mean postoperative HHS was 92. It was not statistically significant because several patients were low sintomatic before surgery, but had raised Cobalt/Chromium levels in the blood. All patients had near-normal levels of Cobalt/Chromium during the first 6 months after revision surgery. No relevant complications were reported. Conclusion: The use of dual-mobility head can be an acceptable option to revise metal-on-metal arthroplasties correctly oriented with abscence of loosening or infection signs and keeping bone stock in young patients. PMID:27857822

  18. Acetabular component deformation with press-fit fixation.

    PubMed

    Squire, Matthew; Griffin, William L; Mason, J Bohannon; Peindl, Richard D; Odum, Susan

    2006-09-01

    Acetabular component deformation secondary to forces encountered during insertion is a potential consequence of the press-fit technique. This study characterized the stiffness of Pinnacle 100 cups (DePuy, Warsaw, Ind) via mechanical testing and used this information with intraoperative measurements of cup deformation to calculate the in vivo forces acting on cups inserted during hip arthroplasty in 21 patients. We found that 90.5% of cups had measurable compression deformity, averaging 0.16 +/- 0.16 mm. The corresponding forces acting on these cups averaged 414 +/- 421 N. For hard-on-hard bearing surfaces, such in vivo deformation of acetabular shells may result in negative clinical consequences such as equatorial loading with increased wear and potential seizing of components, chipping of ceramic inserts, or locking mechanism damage.

  19. Clinical and Radiological Results over the Medium Term of Isolated Acetabular Revision

    PubMed Central

    Andreani, Lorenzo; Bonicoli, Enrico; Niccolai, Francesco; Lisanti, Michele

    2014-01-01

    Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results. PMID:25610894

  20. Fixation strength analysis of cup to bone material using finite element simulation

    NASA Astrophysics Data System (ADS)

    Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; van der Heide, Emile

    2016-04-01

    Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw inside of cup is effective; however, it has little effect in whole fixation. Therefore, an acetabular cup with good fixation, easy manufacture and easy installation is required. This paper is aiming at evaluating and proposing a new cup fixation design. To prove the strength of the present cup fixation design, the finite element simulation of three dimensional cup with new fixation design was performed. The present cup design was examined with twist axial and radial rotation. Results showed that the proposed cup design was better than the general version.

  1. Outcomes of polyethylene liner cementation into a fixed metal acetabular shell with minimum follow-up of 7 years.

    PubMed

    Park, Myung-Sik; Yoon, Sun-Jung; Lee, Ju Rang

    2015-01-01

    Cementation of a polyethylene liner into the well-fixed shell is a convenient option for revision total hip arthroplasty. We retrospectively reviewed 45 patients who had liner cementation to investigate the risk factors which gave rise to major complications and reoperation. Patients were observed for a minimum of 7 years (range 7.8-14 years). Relevant risk factors (age, BMI, surgical approach, previous cup size and position, types of coated surface) were assessed with Cox regression analysis. The mean Harris Hip Score was improved from 62.5 (range 57-68) preoperatively to 87.1 (range 70-97). A total of 7 hips (15.5%) had acetabular component loosening that was treated with reoperation. Prevalence of acetabular component loosening was statistically significantly higher in hydroxyapatite-coated group (5 of 13) than in the Ti-coated group (2 of 32, p = 0.015). All recurrent dislocations occurred in patients treated with a posterior approach. Diameter of the previous metal shell of below 54 mm showed a lower 10-year survival rate than those greater than 54 mm in diameter. PE liner cementation in stable metal cup is a useful alternative option for carefully selected patients. Pre-existing HA-coated cups as well as small sized cups were indicative of poor outcomes.

  2. Relationship between cup position and obturator externus muscle in total hip arthroplasty

    PubMed Central

    2010-01-01

    Background It is often challenging to find the causes for postoperative pain syndromes after total hip replacement, since they can be very allotropic. One possible cause is the muscular impingement syndrome. The most commonly known impingement syndrome is the psoas impingement. Another recently described impingement syndrome is the obturator externus muscle impingement. The aim of this study is to analyze pathological conditions of the Obturator externus and to show possible causes. Methods 40 patients who had undergone a total hip replacement were subjected to clinical and MRI examinations 12 months after the surgery. The Harris Hip Score (HHS) was used to analyze pain and function. Additionally, a satisfaction score and a pain score (VAS) were determined. The MRI allowed for the assessment of the spatial relation between the obturator externus muscle and the acetabulum. Also measured were the acetabular inclination angle as well as the volume and cross-sectional area of the obturator externus muscle. Results The patients were assigned to 3 groups in accordance with their MRI results. Group 1 patients (n = 18) showed no contact between the obturator externus and the acetabulum. Group 2 (n = 13) showed contact, and group 3 (n = 9) an additional clear displacement of the muscle in its course. It was not possible to establish a connection between the imaging findings, the HHS, the VAS, and patient satisfaction. What was striking, however, was a significant difference between the median inclination angle in group 1 (40° ± 5.4°) and group 3 (49° ± 4.7°) (p < 0.05), and the corresponding image-morphological pathology. The average inclination angle in group 2 was 43.3° ± 3.8° Conclusion Contact between the obturator externus muscle and the caudal acetabula border occurs frequently, but is only rarely accompanied by a painful muscular impingement. The position of the acetabula must be seen as one of the main risk factors for contact between the acetabula border

  3. A longitudinal analysis of start position and the outcome of World Cup cross-country mountain bike racing.

    PubMed

    Macdermid, Paul W; Morton, R Hugh

    2012-01-01

    For any athlete competing at the highest level it is vital to understand the components that lead to successful performance. World cup cross-country mountain biking is a complex sport involving large numbers of athletes (100-200) competing for positional advantage over varied off-road terrain. The start has been deemed a major part of performance outcome in such races. The purpose of the present study was to establish the relationship between start and finish position in cross-country mountain bike World Cup events over a 10 year (1997-2007) period and to make comparisons with a model manipulating start position based on predicted athletic capabilities. Data collection and comparisons included results from World Cup events from 1997 to 2007 (males and females), and modelled race data based on potential performance capabilities over the same period. Analyses involved the association of annual plus pooled start and finish position (Kendall's tau) along with banded mean, standard deviation for number of changes in position, while non-constrained linear regression enabled comparison between seasons. Actual race data showed significant positive correlations between starting position and finishing position (P < 0.01) in all cases but less than the model. A mean 57.4% (s = 5.6) of males changed < 15 positions, while 62.9% (s = 9.1) of females changed < 10 positions compared with modelled data (83.6%, s = 0.8 and 91.6%, s = 1.5 for males and females respectively). Individual season comparisons show general patterns to be identical (P > 0.05) for both males and females. In conclusion, finishing position is highly dependent on start position and strategies need to be devised for competing athletes to progress in the sport.

  4. Dynamic virtual simulation of the occurrence and severity of edge loading in hip replacements associated with variation in the rotational and translational surgical position.

    PubMed

    Leng, Joanna; Al-Hajjar, Mazen; Wilcox, Ruth; Jones, Alison; Barton, David; Fisher, John

    2017-04-01

    Variation in the surgical positioning of total hip replacement can result in edge loading of the femoral head on the rim of the acetabular cup. Previous work has reported the effect of edge loading on the wear of hip replacement bearings with a fixed level of dynamic biomechanical hip separation. Variations in both rotational and translational surgical positioning of the hip joint replacement combine to influence both the biomechanics and the tribology including the severity of edge loading, the amount of dynamic separation, the force acting on the rim of the cup and the resultant wear and torque acting on the cup. In this study, a virtual model of a hip joint simulator has been developed to predict the effect of variations in some surgical positioning (inclination and medial-lateral offset) on the level of dynamic separation and the contact force of the head acting on the rim as a measure of severity of edge loading. The level of dynamic separation and force acting on the rim increased with increased translational mismatch between the centres of the femoral head and the acetabular cup from 0 to 4 mm and with increased cup inclination angle from 45° to 65°. The virtual model closely replicated the dynamics of the experimental hip simulator previously reported, which showed similar dynamic biomechanical trends, with the highest level of separation being found with a mismatch of 4 mm between the centres of the femoral head and acetabular cup and 65° cup inclination angle.

  5. A technique to remove a stable all-polyethylene cemented acetabular liner in revision hip arthroplasty: A case report

    PubMed Central

    Judas, Fernando M.; Lucas, Francisco M.; Fonseca, Ruben L.

    2015-01-01

    Introduction The removal of a well-fixed acetabular component in a total hip arthroplasty can cause bone fractures, excessive bleeding, as well as extended bone loss. The reimplantation of a new acetabular component may be compromised. Presentation of case We report a technique using 2 cork-screws for removal a stable cemented acetabular component for the treatment of a recurrent dislocation of a cemented total hip arthroplasty, due to acetabular malposition. Discussion A diversity of approaches and tools has been used for extraction of the acetabular prosthesis. Using 2 cork-screws it is possible to create fissures and fractures into the cement mantle, and greater manual control is obtained facilitating the manipulation of the acetabular component in different directions. The cup-cemented bond can be disrupted, the host bone is preserved and the risks of complications are minimized. Conclusion This technique is simple, available in any environment, reproducible, non-costly, non-timing consuming and safe. PMID:25725330

  6. The influence of friction and interference on the seating of a hemispherical press-fit cup: a finite element investigation.

    PubMed

    Spears, I R; Morlock, M M; Pfleiderer, M; Schneider, E; Hille, E

    1999-11-01

    The formation of gaps in the polar region of acetabular cups is seen as a drawback of press-fit fixation of non-cemented acetabular cups. Recent findings indicate a link between long-term polar gaps and the gaps present directly after implantation. In this study the process of press-fitting is simulated with a linear-elastic two-dimensional axisymmetric finite-element model. The aim of this paper is to investigate the possible importance of friction and interference on the formation of these gaps. A range of cup-bone friction coefficients (mu = 0.1-0.5) is assigned to the cup-bone interface in order to represent the unknown amount of friction occurring during press-fitting. The cup is modeled with a radius of 27 mm, whereas the radius of the cavity is varied between 26.50 and 26.75 mm, thus, creating 0.50 and 0.25 mm radial interference fits. The difference in cavity radius represents the discrepancy between the radius of the last-reamer-used and radius of the cavity it creates. The subchondral plate is considered as being completely removed during reaming. The effects of impact blows via the surgeon's mallet during surgery are modeled as a series of four load pulses, in which peak force is gradually increased from 0.5 to 4.0 kN. The effects of load removal as well as those of load application are investigated. On load application, the cup penetrates into the cavity, and on load removal, the cup rebounds. Depending on the friction, interference and load applied, the position of the cup after the load pulse is somewhere between its position at peak force and its position at the beginning of the pulse. Although the simplifications and conditions involved in the creation of the model necessitate caution when interpreting the results for all clinical cases, it is found that the seating of hemispherical cups in trabecular bone could be more satisfactory for intermediate values of friction (mu = 0.2-0.3) and smaller interference fits (0.25 mm).

  7. The Harris-Galante cementless acetabular component: results in 190 cases with at least 3 years follow-up.

    PubMed

    Claus, B; Van Innis, B; De Witte, E; Van Overschelde, J; Magotteaux, B; Fatemi, F; Vandepaer, F

    1993-01-01

    The results of 190 primary total hip arthroplasties with a Harris-Galante cementless acetabular cup were reviewed. All patients had a minimum follow-up of 3 years (range, 3 to 5.5 years, mean 46 months). Clinical and radiographical analysis was performed. Inguinal pain was recorded in five cases. We noted a fracture of a screw in four cases without further implications. There was no evidence of acetabular loosening. There was no migration of the acetabular cup. No acetabular component showed measurable wear of the polyethylene liner. Non-progressive radiolucent lines were recorded in 14% of the patients: among these patients, radiolucent lines were noted in zone 1 in 46%, in zone 2 in 4% and in zone 3 in 86%. Two socket revisions became necessary. One patient suffered a deep-seated infection. Another revision was necessary because of recurrent dislocation.

  8. Quantification of clearance and creep in acetabular wear measurements

    PubMed Central

    Gregory, Thomas; Vandenbussche, Eric

    2016-01-01

    Background This study aimed to measure femoral head penetration before occurrence of real wear, and to quantify the portions attributable respectively to clearance and plastic deformations in various acetabular designs. Methods We analyzed CT scans from 15 patients at ‘day five’ after total hip arthroplasty (THA). All patients received Exafit® femoral stems and 28 mm heads: 5 patients had cemented Durasul® all-PE cups, 5 patients had un-cemented Allofit® metal-backed cups, and 5 patients had un-cemented Stafit® dual-mobility cups. We also analyzed CT scans of samples of the three head-cup combinations to compare in vivo and in vitro measurements. Results The mean femoral head penetration measured on ‘day five’ was lower for all-PE cups (0.196 mm) than for metal-backed cups (0.551 mm) and dual-mobility cups (0.634 mm). Conclusions The present study indicates that isolated measurements of femoral head penetration include 0.15–0.46 mm of radial clearance and 0.05–0.27 mm of creep, and confirms that the majority of so-called bedding-in observed in the first post-operative months is not entirely due to wear. PMID:27162781

  9. Current concept in dysplastic hip arthroplasty: Techniques for acetabular and femoral reconstruction

    PubMed Central

    Bicanic, Goran; Barbaric, Katarina; Bohacek, Ivan; Aljinovic, Ana; Delimar, Domagoj

    2014-01-01

    Adult patients with developmental dysplasia of the hip develop secondary osteoarthritis and eventually end up with total hip arthroplasty (THA) at younger age. Because of altered anatomy of dysplastic hips, THA in these patients represents technically demanding procedure. Distorted anatomy of the acetabulum and proximal femur together with conjoined leg length discrepancy present major challenges during performing THA in patients with developmental dysplasia of the hip. In addition, most patients are at younger age, therefore, soft tissue balance is of great importance (especially the need to preserve the continuity of abductors) to maximise postoperative functional result. In this paper we present a variety of surgical techniques available for THA in dysplastic hips, their advantages and disadvantages. For acetabular reconstruction following techniques are described: Standard metal augments (prefabricated), Custom made acetabular augments (3D printing), Roof reconstruction with vascularized fibula, Roof reconstruction with pedicled iliac graft, Roof reconstruction with autologous bone graft, Roof reconstruction with homologous bone graft, Roof reconstruction with auto/homologous spongious bone, Reinforcement ring with the hook in combination with autologous graft augmentation, Cranial positioning of the acetabulum, Medial protrusion technique (cotyloplasty) with chisel, Medial protrusion technique (cotyloplasty) with reaming, Cotyloplasty without spongioplasty. For femoral reconstruction following techniques were described: Distraction with external fixator, Femoral shortening through a modified lateral approach, Transtrochanteric osteotomies, Paavilainen osteotomy, Lesser trochanter osteotomy, Double-chevron osteotomy, Subtrochanteric osteotomies, Diaphyseal osteotomies, Distal femoral osteotomies. At the end we present author’s treatment method of choice: for acetabulum we perform cotyloplasty leaving only paper-thin medial wall, which we break during

  10. Fixed-angle screws vs standard screws in acetabular prosthesis fixation: a cadaveric biomechanical study.

    PubMed

    Hugate, Ronald R; Dickey, Ian D; Chen, Qingshan; Wood, Christina M; Sim, Franklin H; Rock, Michael G

    2009-08-01

    Secure fixation of acetabular components in total hip arthroplasty can be challenging. The purpose of this study was to perform biomechanical analysis of cup fixation strength using fixed-angle vs standard screw fixation. Multihole, porous-backed acetabular prostheses were implanted in both acetabuli of 8 cadaveric pelves using standard press-fit techniques. Fixed-angle screws were used on the left side, and standard cancellous screws were used in the right. The use of fixed-angle screws enhanced acetabular fixation substantially under subfailure cyclic loading conditions and load-to-failure. The triradiate screw configuration increases the bending moment required to fail the specimens as well. Fixed-angle screws may be useful for achieving rigid fixation of acetabular prostheses in challenging clinical scenarios.

  11. Uncemented porous tantalum acetabular components: early follow-up and failures in 613 primary total hip arthroplasties.

    PubMed

    Noiseux, Nicolas O; Long, William J; Mabry, Tad M; Hanssen, Arlen D; Lewallen, David G

    2014-03-01

    Uncemented tantalum acetabular components were introduced in 1997. The purpose was to determine the 2- to 10-year results with this implant material in primary total hip arthroplasty. Our registry identified all primary total hip cases with porous tantalum cups implanted from 1997 to 2004. Clinical outcomes and radiographs were studied. 613 cases were identified. Seventeen percent of patients were lost to follow-up. Twenty-five reoperations were performed (4.4%). Acetabular cup removal occurred in 6 cases (1.2%). No cups were revised for aseptic loosening. Incomplete radiolucent lines were found on 9.3% of initial postoperative radiographs. At 2 years, 67% had resolved. Zero new radiolucent lines were detected. Two- to 10-year results of porous tantalum acetabular components for primary total hip arthroplasty demonstrate high rates of initial stability and apparent ingrowth.

  12. Porous Tantalum Buttress Augments for Severe Acetabular Posterior Column Deficiency.

    PubMed

    Meneghini, R Michael; Hull, Jason R; Russo, Glenn S; Lieberman, Jay R; Jiranek, William A

    2015-11-01

    In revision total hip arthroplasty (THA), consensus is lacking regarding the optimal method for reconstruction of the most severe acetabular defects. Porous tantalum (TM) buttress augments were designed for the most severe postero-superior defects. The purpose of this study was to report the results of a consecutive series of acetabular reconstructions utilizing TM buttress augments. Eight complex acetabular reconstructions utilizing a TM buttress augment were performed at two centers. All were Paprosky 3A or Paprosky 3B bone loss classification, with severe superior and posterior column deficiency where wedge augments were insufficient for mechanical support. The acetabular cup sizes ranged from 64-78, and a buttress shim was used in 7 of 8 cases. Clinical and radiographic follow-up averaged 16.5 months (range, 10-28) and no cases were lost to follow-up. There were no cases of clinical or radiographic loosening, and no case had required reoperation or revision. All patients except one were ambulating with either no assist device or a single cane at final follow-up. There was one complication of an iliac wing fracture noted incidentally on postoperative x-rays in the lone patient in whom a buttress shim was not used. At short-term follow-up, TM acetabular buttress augments appear to effectively substitute for the use of structural allografts or cages, which would otherwise be used in this challenging setting. The potential for biologic fixation is promising for the durability of these reconstructions; however, longer-term follow-up is required for full evaluation.

  13. Are porous tantalum cups superior to conventional reinforcement rings?

    PubMed

    Brüggemann, Anders; Fredlund, Erik; Mallmin, Hans; Hailer, Nils P

    2017-02-01

    Background and purpose - Porous tantalum cups have been introduced as an alternative to various reinforcement rings in revision hip surgery. We hypothesized that porous tantalum cups would be superior to Müller acetabular roof reinforcement rings (MARRs) in revision hip surgery with re-revision for aseptic loosening as the primary outcome measure. Patients and methods - 207 hips operated with either a porous tantalum cup (TM cup, n = 111) or a MARR (n = 96) at index procedure were identified in our local arthroplasty register. Acetabular defects were classified according to Paprosky. There were 96 men and 111 women with a median age of 71 (35-95) years, presenting acetabular defect size type I in 39 cases, IIA in 22, IIB in 27, IIC in 43, IIIA in 32, and IIIB in 37 cases. Analysis of medical records identified all patients with subsequent re-revision and reasons for re-revisions. Kaplan-Meier survival functions were used to estimate implant survival. Results - With re-revision for aseptic loosening as the endpoint, the 6-year unadjusted cumulative survival was 97% (95% CI: 94-100) for TM cups and 96% (CI: 92-100) for MARR (p = 0.6). Using re-revision for any reason as the endpoint, 6-year survival was 87% (CI: 81-94) for TM cups and 95% (CI: 90-99) for MARR (p = 0.06). The main reason for re-revision in the TM group was dislocation (n = 10), followed by loosening (n = 3), whereas the main reason for re-revision in the MARR group was aseptic loosening (n = 8). Duration of the index procedure and perioperative blood loss were lower in the TM group. Interpretation - Both TM and MARR lead to good 6-year results in acetabular revision surgery. The methods differ in their respective failure mechanisms. We conclude that TM cups are a valuable treatment option in acetabular revision surgery, but the reasons underlying dislocations after the use of TM cups must be analyzed further.

  14. Are porous tantalum cups superior to conventional reinforcement rings?

    PubMed Central

    Brüggemann, Anders; Fredlund, Erik; Mallmin, Hans; Hailer, Nils P

    2017-01-01

    Background and purpose— Porous tantalum cups have been introduced as an alternative to various reinforcement rings in revision hip surgery. We hypothesized that porous tantalum cups would be superior to Müller acetabular roof reinforcement rings (MARRs) in revision hip surgery with re-revision for aseptic loosening as the primary outcome measure. Patients and methods— 207 hips operated with either a porous tantalum cup (TM cup, n = 111) or a MARR (n = 96) at index procedure were identified in our local arthroplasty register. Acetabular defects were classified according to Paprosky. There were 96 men and 111 women with a median age of 71 (35–95) years, presenting acetabular defect size type I in 39 cases, IIA in 22, IIB in 27, IIC in 43, IIIA in 32, and IIIB in 37 cases. Analysis of medical records identified all patients with subsequent re-revision and reasons for re-revisions. Kaplan-Meier survival functions were used to estimate implant survival. Results— With re-revision for aseptic loosening as the endpoint, the 6-year unadjusted cumulative survival was 97% (95% CI: 94–100) for TM cups and 96% (CI: 92–100) for MARR (p = 0.6). Using re-revision for any reason as the endpoint, 6-year survival was 87% (CI: 81–94) for TM cups and 95% (CI: 90–99) for MARR (p = 0.06). The main reason for re-revision in the TM group was dislocation (n = 10), followed by loosening (n = 3), whereas the main reason for re-revision in the MARR group was aseptic loosening (n = 8). Duration of the index procedure and perioperative blood loss were lower in the TM group. Interpretation— Both TM and MARR lead to good 6-year results in acetabular revision surgery. The methods differ in their respective failure mechanisms. We conclude that TM cups are a valuable treatment option in acetabular revision surgery, but the reasons underlying dislocations after the use of TM cups must be analyzed further. PMID:27892748

  15. Use of porous tantalum for acetabular reconstruction in revision hip arthroplasty.

    PubMed

    Issack, Paul S

    2013-11-06

    ➤ Over the past decade, porous tantalum has emerged as a powerful tool for reconstruction of the failed acetabular component.➤ The increased porosity, high coefficient of friction, and favorable elastic modulus of porous tantalum compared with traditional titanium mesh or cobalt chromium acetabular components allow for greater bone ingrowth potential, implant stability, and host bone preservation, respectively, in porous tantalum shells.➤ Several studies have confirmed the excellent early and midterm results of porous tantalum reconstruction for revision hip arthroplasty.➤ Depending on the degree of bone loss, excellent results have been achieved with modular or revision porous tantalum shells, tantalum shells with tantalum augments, and cup-cage constructs.➤ These implants and techniques are greatly changing the approach to acetabular revision surgery and are providing constructs with greater stability and more physiologic biomechanical properties than those achieved through the use of traditional reconstructive methods.

  16. Evaluating the accuracy of wear formulae for acetabular cup liners.

    PubMed

    Wu, James Shih-Shyn; Hsu, Shu-Ling; Chen, Jian-Horng

    2010-02-01

    This study proposes two methods for exploring the wear volume of a worn liner. The first method is a numerical method, in which SolidWorks software is used to create models of the worn out regions of liners at various wear directions and depths. The second method is an experimental one, in which a machining center is used to mill polyoxymethylene to manufacture worn and unworn liner models, then the volumes of the models are measured. The results show that the SolidWorks software is a good tool for presenting the wear pattern and volume of a worn liner. The formula provided by Ilchmann is the most suitable for computing liner volume loss, but is not accurate enough. This study suggests that a more accurate wear formula is required. This is crucial for accurate evaluation of the performance of hip components implanted in patients, as well as for designing new hip components.

  17. Use of jumbo cups for revision of acetabulae with large bony defects.

    PubMed

    Gustke, Kenneth A; Levering, Melissa F; Miranda, Michael A

    2014-01-01

    Several methods of treatment are available for acetabular revision associated with bone loss. Jumbo cups (minimum diameter of 62 mm in women, 66 mm in men, or 10 mm larger than the normal contralateral acetabulum) are often useful for large defects. The purpose of this study is to report a large jumbo cup series with an average 10-year follow-up. A total of 196 jumbo cups in 186 patients with a minimum of 2-year follow-up were available for review. Harris hip score improved from 44 preoperatively to 72 postoperatively. Survivorship was 98% at 4 years and 96% at 16 years. Five revisions and two resection arthroplasties were performed for failure. In conclusion, porous jumbo cup acetabular revision with supplemental screw fixation provides good to excellent intermediate- and long-term outcomes.

  18. Shape variability of the adult human acetabulum and acetabular fossa related to sex and age by geometric morphometrics. Implications for adult age estimation.

    PubMed

    San-Millán, Marta; Rissech, Carme; Turbón, Daniel

    2017-03-01

    This study aims to explore shape variability of the acetabulum during the human adult life span, in relation to sex and age. The human acetabular shape was analysed in 682 os coxae from three different documented skeletal collections from the Iberian Peninsula. Two landmarks and thirty-two sliding semi-landmarks were used for the geometric morphometric procedures and a clock-wise standard was used for orientation. The 180° meridian (6:00) line was positioned over the midpoint of the acetabular notch and 36 reference points in 10° increments along the rim were marked. Data showed that size, sex and age significantly influence acetabular shape variation. Sex differences were significant in individuals younger than 65 years old and were characterised by males exhibiting relatively extended acetabular rim profiles from 10:00 to 1:00, narrower acetabular notches, and reduced acetabular fossae. In addition, three main age-related changes occurred to the acetabular shape in both sexes: outer acetabular profile modification, with extension from 10:00 to 1:00 and reduction from 7:00 to 9:00, acetabular notch narrowing, and acetabular fossa reduction. The age-related changes that were observed are shared by both sexes and seem to be related to bone production associated with age. Specifically, age appears to affect the entire border of the lunate surface: the acetabular rim, both acetabular horns, and the outer edge of the acetabular fossa. Furthermore, shape data confirmed the clover-leaf shape of the acetabular fossa in both males and females. These results improve our understanding of acetabular shape, and assist in refining age-estimation methods and enhancing hip surgery and rehabilitation.

  19. Direct high-resolution ion beam-profile imaging using a position-sensitive Faraday cup array

    SciTech Connect

    Panitzsch, Lauri; Stalder, Michael; Wimmer-Schweingruber, Robert F.

    2009-11-15

    Ion sources have wide-spread use in a multitude of applications. For many, an accurate knowledge, or better, an accurate imaging, of the beam profile and intensity is an important criterion. We are developing an ion source to calibrate instruments for space-based measurements of solar wind and suprathermal particles in the energy range from below 1 keV/nuc to above 200 keV/nuc. In order to establish accurate beam profiles for calibration purposes, we have developed a new method based on an array of very small (diameter = 0.3 mm) Faraday cups. Here, we describe the experimental setup and discuss how to achieve several requirements such as a large thermal load due to the {approx}40W of beam power.

  20. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

    PubMed Central

    2011-01-01

    The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA). One hundred 'and one (94.4%) acetabular components did not show significant migration of more than 1 mm. Six (5.6%) implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration. PMID:21486725

  1. Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population

    PubMed Central

    Xiao, Jian-Lin; Zuo, Jian-Lin; Liu, Peng; Qin, Yan-Guo; Li, Xue-Zhou; Liu, Tong; Gao, Zhong-Li

    2015-01-01

    Background: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. Methods: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. Results: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. Conclusions: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better. PMID:26063357

  2. [Application of three-dimensional printing personalized acetabular wing-plate in treatment of complex acetabular fractures via lateral-rectus approach].

    PubMed

    Mai, J G; Gu, C; Lin, X Z; Li, T; Huang, W Q; Wang, H; Tan, X Y; Lin, H; Wang, Y M; Yang, Y Q; Jin, D D; Fan, S C

    2017-03-01

    Objective: To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach. Methods: From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision. Results: All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month's follow-up, who didn't accept any treatment because the patient didn't feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all

  3. Comparison of vacuum extraction delivery between the conventional metal cup and the new soft rubber cup.

    PubMed

    Srisomboon, J; Piyamongkol, W; Sahapong, V; Mongkolchaipak, S

    1998-07-01

    To compare the effectiveness and complications of vacuum extraction delivery between the conventional metal cup and the silicone rubber cup. A prospective randomized clinical trial of 90 pregnant women requiring assisted vaginal delivery who met the predetermined criteria for vacuum extraction were allocated to delivery by the Malstrom metal cup (46 cases) or the silicone rubber cup (44 cases). The two groups were similar in respect of age, parity gestational age and indications for assisted vaginal delivery. The mean and median numbers of tractions and time from cup application to delivery were not significantly different between the groups. The overall success rate was higher in the metal cup (89.1%) than in the rubber cup (79.5%) but not significantly different. The silicone cup was more likely to fail in cases of occiput posterior position, excessive caput, and severe degree of molding. There were no significant differences between groups in terms of Apgar scores, birth canal injury, and maternal blood loss. Scalp injuries occurred more frequently with the metal than with the rubber cup (P = 0.006). Vacuum extraction delivery with the silicone rubber cup is associated with reduced scalp injuries but has a greater tendency to fail when the fetus presents in occiput posterior position, has excessive caput or severe degree of molding.

  4. Vacuum extraction: a randomized controlled comparison of the New Generation cup with the original Bird cup.

    PubMed

    Carmody, F; Grant, A; Somchiwong, M

    1986-01-01

    A new design of vacuum extractor cup--'the New Generation cup'--has recently been introduced into clinical practice. Its major modification is a traction cord which passes around the rim of the cup for 180 degrees and is free to slide within the rim. Claims that this design 'enables the operator to pull obliquely without causing the cup to tilt' and thereby 'reduces failure rates, reduces the incidence of scalp trauma and increases operator confidence' have been evaluated in a randomized controlled trial. 123 women with singleton pregnancies of 37 completed weeks or more, with a cephalic presentation and for whom a decision to deliver by vacuum extraction had been taken, were randomly allocated to the 'New Generation' cup or BIRD's original vacuum extractor cup; 50 mm anterior and posterior cups were used in both groups as appropriate. The two groups were comparable at entry and delivered by obstetricians of similar status. The two types of cup were similar in respect of number of failures to deliver with the vacuum extractor, correct positioning of the cup, number of pulls required for delivery and time taken to expedite delivery. Cup detachments occurred in nine cases allocated to the 'New Generation' cup compared with four allocated to the original BIRD cup. The babies in the two groups were in similar condition at birth and sustained similar amounts of scalp trauma. Neonatal jaundice, both clinical and biochemical, was more common in babies delivered with the 'New Generation cup' and this was reflected in greater use of phototherapy in this group. Operators were equally divided in their preference of cup.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Early proximal migration of cups is associated with late revision in THA

    PubMed Central

    2012-01-01

    Background and purpose The association between excessive early migration of acetabular cups and late aseptic revision has been scantily reported. We therefore performed 2 parallel systematic reviews and meta-analyses to determine the association between early migration of acetabular cups and late aseptic revision. Methods One review covered early migration data from radiostereometric analysis (RSA) studies, while the other focused on revision rates for aseptic loosening from long-term survival studies. Thresholds for acceptable and unacceptable migration were classified according the Swedish Hip Arthroplasty Register and the Australian National Joint Replacement Registry: < 5% revision at 10 years. Results Following an elaborate literature search, 26 studies (involving 700 cups) were included in the RSA review and 49 studies (involving 38,013 cups) were included in the survival review. For every mm increase in 2-year proximal migration, there was a 10% increase in revision rate, which remained after correction for age, sex, diagnosis, hospital type, continent, and study quality. Consequently, proximal migration of up to 0.2 mm was considered acceptable and proximal migration of 1.0 mm or more was considered unacceptable. Cups with proximal migration of between 0.2 and 1.0 mm were considered to be at risk of having revision rates higher than 5% at 10 years. Interpretation There was a clinically relevant association between early migration of acetabular cups and late revision due to loosening. The proposed migration thresholds can be implemented in a phased evidence-based introduction, since they allow early detection of high-risk cups while exposing a small number of patients. PMID:23126575

  6. Can A Cup Anemometer `Underspeed'?

    NASA Astrophysics Data System (ADS)

    Kristensen, L.

    An analysis of cup-anemometer dynamics has been carried out inorder to determine whether the mean-wind velocity can have anegative bias. This would be contrary to the general belief thatcup anemometers always overspeed. Compared to prior analyses, theeffect of a possible nonlinearity of the calibration function isincluded. The conclusion is that neither longitudinal nor lateralvelocity fluctuations can contribute significantly to a negativebias. However, if a cup anemometer has an angular response thatfalls below the ideal cosine response, there will, as demonstratedin the concluding discussion, be a negative contribution from thevertical velocity fluctuations to the total bias, and thiscontribution may even outbalance the positive contributions fromthe longitudinal velocity fluctuations. Concrete evidence of suchexotic cup anemometer behaviour has not been reported in theliterature.

  7. Clinical and radiological outcome of the cemented Contemporary acetabular component in patients < 50 years of age.

    PubMed

    Schmitz, M W J L; Timmer, C; Rijnen, W H C; Gardeniers, J W M; Schreurs, B W

    2013-12-01

    Despite the worldwide usage of the cemented Contemporary acetabular component (Stryker), no published data are available regarding its use in patients aged < 50 years. We undertook a mid- to long-term follow-up study, including all consecutive patients aged < 50 years who underwent a primary total hip replacement using the Contemporary acetabular component with the Exeter cemented stem between January 1999 and January 2006. There were 152 hips in 126 patients, 61 men and 65 women, mean age at surgery 37.6 years (16 to 49 yrs). One patient was lost to follow-up. Mean clinical follow-up of all implants was 7.6 years (0.9 to 12.0). All clinical questionnaire scores, including Harris hip score, Oxford hip score and several visual analogue scales, were found to have improved. The eight year survivorship of all acetabular components for the endpoints revision for any reason or revision for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2 to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up was complete for 146 implants. The eight year survival for the endpoint radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving implants were considered radiologically loose but were asymptomatic. The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent lines (n = 20, 13.9%) in the 144 surviving cups indicates a need for continued observation in the second decade of follow-up in order to observe their influence on long-term survival. The clinical and radiological data resulting in a ten-year survival rate > 90% in young patients support the use of the Contemporary acetabular component in this specific patient group.

  8. 10-year results of the uncemented Allofit press-fit cup in young patients

    PubMed Central

    Streit, Marcus R; Weiss, Stefan; Andreas, Franziska; Bruckner, Thomas; Walker, Tilman; Kretzer, J Philippe; Ewerbeck, Volker; Merle, Christian

    2014-01-01

    Background and purpose Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. Methods We examined the clinical and radiographic results of our first 121 consecutive cementless THAs using a cementless, grit-blasted, non-porous, titanium alloy press-fit cup (Allofit; Zimmer Inc., Warsaw, IN) without additional screw fixation in 116 patients. Mean age at surgery was 51 (21–60) years. Mean time of follow-up evaluation was 11 (10–12) years. Results At final follow-up, 8 patients had died (8 hips), and 1 patient (1 hip) was lost to follow-up. 3 hips in 3 patients had undergone acetabular revision, 2 for deep infection and 1 for aseptic acetabular loosening. There were no impending revisions at the most recent follow-up. We did not detect periacetabular osteolysis or loosening on plain radiographs in those hips that were evaluated radiographically (n = 90; 83% of the hips available at a minimum of 10 years). Kaplan-Meier survival analysis using revision of the acetabular component for any reason (including isolated inlay revisions) as endpoint estimated the 11-year survival rate at 98% (95% CI: 92–99). Interpretation Uncemented acetabular fixation using the Allofit press-fit cup without additional screws was excellent into early in the second decade in this young and active patient cohort. The rate of complications related to the liner and to osteolysis was low. PMID:24875058

  9. The effect of under-reaming on the cup/bone interface of a press fit hip replacement.

    PubMed

    Zivkovic, I; Gonzalez, M; Amirouche, F

    2010-04-01

    This paper explores the effect of under-reaming on micromotion at the cup/bone interface of a press-fit acetabular cup. A cadaver experiment was performed on 11 acetabuli implanted with a cementless acetabular cup. The loading profile simulated hip impingement at the extremes of motion and subluxation relocation of the hip joint. Micromotion of each cup was measured in a custom made jig with linear variable differential transducers. A CAT scan and DEXA scan of the acetabulum and femoral head respectively were used to construct a three-dimensional patient specific finite element model of the hemi-pelvis. The model predicted cup micromotion under loading conditions and stresses in the acetabulum as a result of cup insertion. Micromotion was then calculated as a function of variable bone density and variable degree of underreaming. Simulated cup insertion with under-reaming of 2 mm or more approached or exceeded the yield strength of bone in acetabula with reduced bone mass density.

  10. Dual mobility cups in total hip arthroplasty

    PubMed Central

    De Martino, Ivan; Triantafyllopoulos, Georgios Konstantinos; Sculco, Peter Keyes; Sculco, Thomas Peter

    2014-01-01

    Total hip arthroplasty (THA) is considered one of the most successful surgical procedures in orthopaedics. With the increase in the number of THAs performed in the world in the next decades, reducing or preventing medical and mechanical complications such as post-operative THA instability will be of paramount importance, particularly in an emerging health care environment based on quality control and patient outcome. Dual mobility acetabular component (also known as unconstrained tripolar implant) was introduced in France at the end of the 1970s as an alternative to standard sockets, to reduce the risk of THA dislocation in patients undergoing primary THA in France. Dual mobility cups have recently gained wider attention in the United States as an alternative option in the prevention and treatment of instability in both primary and revision THA and offer the benefit of increased stability without compromising clinical outcomes and implant longevity. In this article, we review the use of dual mobility cup in total hip arthroplasty in terms of its history, biomechanics, outcomes and complications based on more than 20 years of medical literature. PMID:25035820

  11. The use of a constrained cementless acetabular component for instability in total hip replacement.

    PubMed

    Rady, Ahmad Emad; Asal, Mohammed Kamal; Bassiony, Ayman Abdelaziz

    2010-01-01

    Recurrent dislocation after total hip arthroplasty is a disabling complication that can be difficult to treat. We evaluated the early clinical and radiographic outcome associated with the use of a constrained acetabular component for instability in total hip arthroplasty. Fifteen patients underwent either primary or revision total hip arthroplasty with a cementless constrained acetabular component for different indications. The mean patient age at surgery was 57.4 years and the mean clinical and radiological follow-up period was 26.4 months. Clinical assessment was performed by the Harris hip score and at the latest follow up patients reported outcome using the Oxford hip score questionnaire. All radiographs were evaluated for evidence of loosening. Only one patient experienced redislocation with the constrained prosthesis. The average Harris hip score increased from a preoperative mean of 22 (range, 16 - 36) to a postoperative mean of 85 (range, 66-94). Preoperatively, the mean Oxford Hip Score was 48.6, which decreased to 20.5 at the final examination. All but one of the 15 hips had a well-fixed, stable cup. Femoral component stability with bone ingrowth was achieved in 10 cases. A constrained acetabular component is an effective option for the treatment of hip instability in primary and revision arthroplasty in those at high risk of dislocation. The potential for aseptic loosening requires evaluation by long term studies.

  12. Outcome of porous tantalum acetabular components for Paprosky type 3 and 4 acetabular defects.

    PubMed

    Batuyong, Eldridge D; Brock, Hugh S; Thiruvengadam, Nikhil; Maloney, William J; Goodman, Stuart B; Huddleston, James I

    2014-06-01

    Porous tantalum acetabular implants provide a potential solution for dealing with significant acetabular bone loss. This study reviews 24 acetabular revisions using tantalum implants for Paprosky type 3 and 4 defects. The mean Harris Hip Score improved from 35 ± 19 (range, 4-71) to 88 ± 14 (range, 41-100), p < 0.0001. Postoperative radiographs showed radiolucent lines in 14 hips with a mean width of 1.3 ± 1.0 mm (range, 0.27-4.37 mm). No gaps enlarged and 71% of them disappeared at a mean of 13 ± 10 months (range, 3-29 months). At a mean follow-up of 37 ± 14 months (range, 24-66 months), 22 reconstructions showed radiograpic evidence of osseointegration (92%). The two failures were secondary to septic loosening. When dealing with severe acetabular bone loss, porous tantalum acetabular components show promising short-term results.

  13. Management of an Open Acetabular Fracture in a Skeletally Immature Patient

    PubMed Central

    Clutter, Sarah Y; Morgan, Steven J; Erickson, Mark; Smith, Wade R; Stahel, Philip F

    2007-01-01

    Background: Open acetabular fractures in children are rare, but potentially devastating injuries. Secondary to the low incidence, there is an apparent lack of reports on appropriate management strategies for open pediatric acetabular fractures in the literature. Methods: Description of a case study. Results: A 3 years and ten months-old girl was ejected as a passenger from an all terrain vehicle. She sustained a displaced, grade IIIA open left anterior column acetabular fracture. The injury was treated by extending the open wound to a formal first window of the ilioinguinal approach. After surgical debridement, the anterior column was reduced anatomically and fixed by two lag screws which avoided the tri-radiate cartilage. A vaginal laceration was debrided and repaired. The patient was treated in a spica cast without weight bearing on the left lower extremity for 8 weeks. No perioperative complications occurred. The acetabular fracture healed in an anatomic position within 8 weeks. To avoid premature closure of the tri-radiate cartilage, the patient underwent a physeal bar resection at one year after injury. At two-year follow up, she was walking and running without pain and had a free range of motion of her left hip. Conclusions: Operative management should represent the therapy of choice for open, displaced pediatric acetabular fractures. After fracture healing, a scheduled physeal bar resection may be required for injuries which involve the tri-radiate cartilage. PMID:19461903

  14. Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study

    PubMed Central

    Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin

    2012-01-01

    Background Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Methods Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. Results The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78±8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65±0.29 mm3/MC and 0.89±0.04 mm3/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. Conclusions This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. Clinical Relevance This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care. PMID:23144694

  15. Explicit finite element modelling of the impaction of metal press-fit acetabular components.

    PubMed

    Hothi, H S; Busfield, J J C; Shelton, J C

    2011-03-01

    Metal press-fit cups and shells are widely used in hip resurfacing and total hip replacement procedures. These acetabular components are inserted into a reamed acetabula cavity by either impacting their inner polar surface (shells) or outer rim (cups). Two-dimensional explicit dynamics axisymmetric finite element models were developed to simulate these impaction methods. Greater impact velocities were needed to insert the components when the interference fit was increased; a minimum velocity of 2 m/s was required to fully seat a component with a 2 mm interference between the bone and outer diameter. Changing the component material from cobalt-chromium to titanium alloy resulted in a reduction in the number of impacts on the pole to seat it from 14 to nine. Of greatest significance, it was found that locking a rigid cap to the cup or shell rim resulted in up to nine fewer impactions being necessary to seat it than impacting directly on the polar surface or using a cap free from the rim of the component, as is the case with many commercial resurfacing cup impaction devices currently used. This is important to impactor design and could make insertion easier and also reduce acetabula bone damage.

  16. Acetabular blood flow during total hip arthroplasty

    PubMed Central

    ElMaraghy, Amr W.; Schemitsch, Emil H.; Waddell, James P.

    2000-01-01

    Objective To determine the immediate effect of reaming and insertion of the acetabular component with and without cement on periacetabular blood flow during primary total hip arthroplasty (THA). Design A clinical experimental study. Setting A tertiary referral and teaching hospital in Toronto. Patients Sixteen patients (9 men, 7 women) ranging in age from 30 to 78 years and suffering from arthritis. Intervention Elective primary THA with a cemented (8 patients) and noncemented (8 patients) acetabular component. All procedures were done by a single surgeon who used a posterior approach. Main outcome measure Acetabular bone blood-flow measurements made with a laser Doppler flowmeter before reaming, after reaming and after insertion of the acetabular prosthesis. Results Acetabular blood flow after prosthesis insertion was decreased by 52% in the noncemented group (p < 0.001) and 59% in the cemented group (p < 0.001) compared with baseline (prereaming) values. Conclusion The significance of these changes in periacetabular bone blood flow during THA may relate to the extent of bony ingrowth, periprosthetic remodelling and ultimately the incidence of implant failure because of aseptic loosening. PMID:10851413

  17. Effects of hydroxyapatite coating of cups used in hip revision arthroplasty

    PubMed Central

    2012-01-01

    Background and purpose Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. Methods We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip Arthroplasty Register (SHAR). 2 such cup designs were identified: Harris-Galante and Trilogy, both available either with or without HA coating. These cups had been used as revision components in 1,780 revisions of total hip arthroplasties (THA) between 1986 and 2009. A Cox proportional hazards model including the type of coating, age at index revision, sex, cause of cup revision, cup design, the use of bone graft at the revision procedure, and the type of cup fixation at primary THA were used to calculate adjusted risk ratios (RRs with 95% CI) for re-revision for any reason or due to aseptic loosening. Results 71% of the cups were coated with HA and 29% were uncoated. At a mean follow-up time of 6.9 (0–24) years, 159 (9%) of all 1,780 cups had been re-revised, mostly due to aseptic loosening (5%), dislocation (2%), or deep infection (1%). HA coating had no significant influence on the risk of re-revision of the cup for any reason (RR = 1.4, CI: 0.9–2.0) or due to aseptic loosening (RR = 1.1, 0.6–1.9). In contrast, HA coating was found to be a risk factor for isolated liner re-revision for any reason (RR = 1.8, CI: 1.01–3.3). Age below 60 years at the index cup revision, dislocation as the cause of the index cup revision, uncemented cup fixation at primary THA, and use of the Harris-Galante cup also increased the risk of re-revision of the cup. In separate analyses in which isolated liner revisions were excluded, bone grafting was found to be a risk factor for re-revision of the metal shell due to aseptic loosening (RR = 2.1, CI: 1.05–4.2). Interpretation We found no

  18. Bleeding and cupping.

    PubMed Central

    Turk, J. L.; Allen, E.

    1983-01-01

    Bleeding and cupping have been used in medicine since ancient times in the treatment of fevers and local inflammatory disorders. Local bleeding, by 'wet cupping', was effected by a scarificator or by leeches. John Hunter recommended venesection in moderation but preferred leeches for local bleeding. Bleeding as an accepted therapeutic practice went out of vogue in the middle of the nineteenth century as a result of the introduction of modern scientific methods. Dry cupping and the use of leeches, as counter irritants, persisted until the middle of this century. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:6338802

  19. Acetabular pneumatocyst containing air-fluid level.

    PubMed

    Narváez, J A; Narváez, J; Rodríguez-Mijarro, M; Quintero, J C

    1999-01-01

    The presence of intraosseous gas most commonly occurs in osteomyelitis, vacuum phenomenon, and postsurgery or posttraumatic states. Several cases of subchondral gas-filled lesions, called pneumatocysts, have also been described in the sacroiliac joint and clavicle, none of them with intralesional air-fluid level. These pneumatocysts are innocuous lesions of uncertain origin. We describe one case of acetabular pneumatocyst containing air-fluid level in a 62-year-old man with long-standing ankylosing spondylitis involving hip joint. To our knowledge, this is the first reported case of a pneumatocyst in an acetabular location containing air-fluid level.

  20. The acetabular point: a morphological and ontogenetic study

    PubMed Central

    RISSECH, C.; SAÑUDO, J. R.; MALGOSA, A.

    2001-01-01

    The acetabular point was analysed by studying human pelvic bones from 326 individuals ranging from newborns to age 97 y. The bones were categorised into 3 groups according to the degree of fusion for the 3 elements of the pelvis: nonfused (59), semifused (5) and fused (262). The acetabular point in immature pelvic bones is clearly represented by the point of the fusion lines for each bony element at the level of the acetabular fossa. In adult pelvic bones the acetabular fossa has an irregular clover-leaf shape, the superior lobe being smaller than the anterior and posterior lobes. Cross-sectional analysis of acetabular morphology suggested that the acetabular point in adult pelvic bones is always represented by the indentation between the superior and the anterior lobes of the acetabular fossa. PMID:11465866

  1. Mathematical analysis of the effect of rotor geometry on cup anemometer response.

    PubMed

    Sanz-Andrés, Ángel; Pindado, Santiago; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance.

  2. Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

    PubMed Central

    Sanz-Andrés, Ángel; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance. PMID:25110735

  3. The effect of the Rim Cutter on cement pressurization and penetration on cemented acetabular fixation in total hip arthroplasty: an in vitro study.

    PubMed

    Smith, B N; Lee, A J C; Timperley, A J; Whitehouse, S L; Crawford, R W

    2010-01-01

    The Rim Cutter (Stryker Orthopedics, Mahwah, New Jersey) is a tool designed to cut a ledge inside the rim of the acetabulum, onto which a precisely trimmed, cemented, flanged cup can be fitted. The aim was to investigate the effect of the Rim Cutter on the intra-acetabular cement mantle pressure and the depth of cement penetration during cup insertion. The study had two parts. In the first part, hemi-pelvis models were fitted with pressure sensors. Pressure in the acetabulum was measured on insertion of a conventional cemented flanged cup with and without the use of a Rim Cutter to prepare the rim of the acetabulum. The second part assessed cement penetration when the same cups were inserted into a foam shell model. The shell was mounted in a jig and had holes drilled in it; the distance that cement penetrated into the holes was measured. A significant increase in cement pressure at the apex (p = 0.04) and the rim (p = 0.004) is seen when the Rim Cutter is used. Cement penetration in the Rim Cutter group was significantly increased at the rim of the acetabulum (p = 0.003). Insertion of a flanged cup after the acetabulum is prepared with the Rim Cutter leads to a significant increase in cement pressure and penetration during cup insertion in vitro when compared with conventional flanged cups.

  4. Automated measurement of anterior and posterior acetabular sector angles

    NASA Astrophysics Data System (ADS)

    Ibragimov, Bulat; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2012-03-01

    In this paper, we propose a segmentation algorithm by which anatomical landmarks on the pelvis are extracted from computed tomography (CT) images. The landmarks are used to automatically define the anterior (AASA) and posterior acetabular sector angles (PASA) describing the degree of hip misalignment. The center of each femoral head is obtained by searching for the point at which most intensity gradient vectors defined at edge points intersect. The radius of each femoral head is computed by finding the sphere, positioned at the center of the femoral head, for which the normalized sum of gradient vector magnitudes on the sphere surface is maximal. The anterior and posterior corners of each acetabulum are searched for on a curve representing the acetabulum and defined by dynamic programming. The femoral head centers and anterior and posterior corners are used to calculate the AASA and PASA. The algorithm was applied to CT images of 120 normal subjects and the results were compared to ground truth values obtained by manual segmentation. The mean absolute difference (+/- standard deviation) between the obtained and ground truth values was 1.3 +/- 0.3 mm for the femoral head centers and 2.1 +/- 1.3 degrees for the acetabular angles.

  5. Perceptual elements in Penn & Teller's "Cups and Balls" magic trick.

    PubMed

    Rieiro, Hector; Martinez-Conde, Susana; Macknik, Stephen L

    2013-01-01

    Magic illusions provide the perceptual and cognitive scientist with a toolbox of experimental manipulations and testable hypotheses about the building blocks of conscious experience. Here we studied several sleight-of-hand manipulations in the performance of the classic "Cups and Balls" magic trick (where balls appear and disappear inside upside-down opaque cups). We examined a version inspired by the entertainment duo Penn & Teller, conducted with three opaque and subsequently with three transparent cups. Magician Teller used his right hand to load (i.e. introduce surreptitiously) a small ball inside each of two upside-down cups, one at a time, while using his left hand to remove a different ball from the upside-down bottom of the cup. The sleight at the third cup involved one of six manipulations: (a) standard maneuver, (b) standard maneuver without a third ball, (c) ball placed on the table, (d) ball lifted, (e) ball dropped to the floor, and (f) ball stuck to the cup. Seven subjects watched the videos of the performances while reporting, via button press, whenever balls were removed from the cups/table (button "1") or placed inside the cups/on the table (button "2"). Subjects' perception was more accurate with transparent than with opaque cups. Perceptual performance was worse for the conditions where the ball was placed on the table, or stuck to the cup, than for the standard maneuver. The condition in which the ball was lifted displaced the subjects' gaze position the most, whereas the condition in which there was no ball caused the smallest gaze displacement. Training improved the subjects' perceptual performance. Occlusion of the magician's face did not affect the subjects' perception, suggesting that gaze misdirection does not play a strong role in the Cups and Balls illusion. Our results have implications for how to optimize the performance of this classic magic trick, and for the types of hand and object motion that maximize magic misdirection.

  6. Acetabular augmentation induced by extracorporeal shock waves in rabbits.

    PubMed

    Saisu, Takashi; Kamegaya, Makoto; Wada, Yuichi; Takahashi, Kenji; Mitsuhashi, Shigeru; Moriya, Hideshige; Maier, Markus

    2005-05-01

    We conducted this animal study to demonstrate whether exposing the acetabulum in immature rabbits to extracorporeal shock waves induces bone formation in the acetabulum. Five thousand shock waves of 100 MPa each were directed, from outside, at the acetabular roof of eight immature rabbits. At each of two time points (4 and 8 weeks) after treatment, the pelvises of four rabbits were removed and evaluated morphologically. Woven bone formation was observed on the lateral margin of the acetabular roof at 4 weeks after treatment, and the breadth of the acetabular roof in the coronal plane was significantly increased. Eight weeks after treatment, the woven bone disappeared; the breadth of the acetabular roof, however, was significantly increased. These findings demonstrated that extracorporeal shock waves induced acetabular augmentation in rabbits. We conclude that extracorporeal shock waves, perhaps, could be applied clinically for the treatment of acetabular dysplasia.

  7. Meralgia Paresthetica and Femoral Acetabular Impingement: A Possible Association

    PubMed Central

    Ahmed, Aiesha

    2010-01-01

    Meralgia paresthetica consists of pain and dysesthesia in the anterolateral thigh. Etiology is divided into spontaneous and iatrogenic causes. To my knowledge this has never been attributed to femoral acetabular impingement. This case highlights the presence of lateral femoral cutaneous neuropathy in the setting of femoral acetabular impingement syndrome thus raising the possibility of an association. Keywords Femoral acetabular impingement; Lateral femoral cutaneous nerve; Dysesthesia; Nerve conduction studies PMID:22043261

  8. Comparison of Conventional Polyethylene Wear and Signs of Cup Failure in Two Similar Total Hip Designs

    PubMed Central

    Pace, Thomas B.; Keith, Kevin C.; Snider, Rebecca G.; Tanner, Stephanie L.; DesJardins, John D.

    2013-01-01

    Multiple factors have been identified as contributing to polyethylene wear and debris generation of the acetabular lining. Polyethylene wear is the primary limiting factor in the functional behavior and consequent longevity of a total hip arthroplasty (THA). This retrospective study reviewed the clinical and radiographic data of 77 consecutive THAs comparing in vivo polyethylene wear of two similar acetabular cup liners. Minimum follow-up was 7 years (range 7–15). The incidence of measurable wear in a group of machined liners sterilized with ethylene oxide and composed of GUR 1050 stock resin was significantly higher (61%) than the compression-molded, GUR 1020, O2-free gamma irradiation sterilized group (24%) (P = 0.0004). Clinically, at a 9-year average followup, both groups had comparable HHS scores and incidence of thigh or groin pain, though the machined group had an increased incidence of osteolysis and annual linear wear rate. PMID:23662210

  9. Syndrome of symptomatic adult acetabular dysplasia (SAAD syndrome)

    PubMed Central

    Birrell, F; Silman, A; Croft, P; Cooper, C; Hosie, G; Macfarlane, G

    2003-01-01

    Design: Cross sectional analysis of a prospective cohort. Setting: 35 general practices across the UK. Subjects: 195 patients (63 male, 132 female) aged 40 years and over presenting with a new episode of hip pain Results: The prevalence of acetabular dysplasia in this study of new presenters with hip pain was high (32%). There was no significant relationship between acetabular dysplasia and radiographic OA overall. Conclusions: The high prevalence of acetabular dysplasia across all grades of OA severity suggests that dysplasia itself may be an important cause of hip pain ("symptomatic adult acetabular dysplasia"). PMID:12634238

  10. Miniature modified Faraday cup for micro electron beams

    DOEpatents

    Teruya, Alan T.; Elmer, John W.; Palmer, Todd A.; Walton, Chris C.

    2008-05-27

    A micro beam Faraday cup assembly includes a refractory metal layer with an odd number of thin, radially positioned traces in this refractory metal layer. Some of the radially positioned traces are located at the edge of the micro modified Faraday cup body and some of the radially positioned traces are located in the central portion of the micro modified Faraday cup body. Each set of traces is connected to a separate data acquisition channel to form multiple independent diagnostic networks. The data obtained from the two diagnostic networks are combined and inputted into a computed tomography algorithm to reconstruct the beam shape, size, and power density distribution.

  11. Complementary Coffee Cups

    ERIC Educational Resources Information Center

    Banchoff, Thomas

    2006-01-01

    What may have been the birth of a new calculus problem took place when the author noticed that two coffee cups, one convex and one concave, fit nicely together, and he wondered which held more coffee. The fact that their volumes were about equal led to the topic of this article: complementary surfaces of revolution with equal volumes.

  12. The perennial cup anemometer

    NASA Astrophysics Data System (ADS)

    Kristensen, L.

    1999-01-01

    A short version of the history of the cup anemometer precedes a more technical discussion of the special features of this instrument. These include its extremely linear calibration and the non-linearity of its response to wind speed changes. A simple conceptual model by Schrenk is used to demonstrate this and to explain why the cup anemometer is able to start from a zero rotation rate at zero wind to one corresponding to a sudden change in the ambient wind speed to a finite value. The same model is used to show that the cup anemometer should be characterized by a distance constant rather than by a time constant. The bias in the measured mean wind speed due to the random variations in the three velocity components is discussed in terms of standard, semiquantitative turbulence models, and the main thesis is that this bias is overwhelmingly dominated by the fluctuations of the lateral wind velocity component, i.e. the wind component perpendicular to the mean wind direction, and not, as is often assumed, by the longitudinal wind velocity component. It is shown theoretically and tested experimentally that the bias due to lateral wind velocity fluctuations can be significantly reduced by means of a special data processing of the simultaneous signals from a cup anemometer and a wind vane. This means that, with care, the overall overspeeding can be reduced to less than 1%.

  13. Compact rotating cup anemometer

    NASA Technical Reports Server (NTRS)

    Wellman, J. B.

    1968-01-01

    Compact, collapsible rotating cup anemometer is used in remote locations where portability and durability are factors in the choice of equipment. This lightweight instrument has a low wind-velocity threshold, is capable of withstanding large mechanical shocks while in its stowed configuration, and has fast response to wind fluctuations.

  14. Cups and Downs

    ERIC Educational Resources Information Center

    Stewart, Ian

    2012-01-01

    Martin Gardner wrote about a coin-flipping trick, performed by a blindfolded magician. The paper analyses this trick, and compares it with a similar trick using three cups flipped in pairs. Several different methods of analysis are discussed, including a graphical analysis of the state space and a representation in terms of a matrix. These methods…

  15. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    PubMed Central

    DeBuitleir, Cathal; Soden, Philip; O'Donnchadha, Brian; Tansey, Anthony; Abdulkarim, Ali; McMahon, Colm; Hurson, Conor J.

    2017-01-01

    Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D) representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice. PMID:28168060

  16. Does the lumbar spine need to be supported to stabilize the pelvis during total hip arthroplasty in the lateral position?

    PubMed

    Prakash, D; King, R; Hayes, C

    2002-04-01

    Total hip arthroplasty is done commonly with the patient in the lateral position. It has been postulated that the lumbar spine may sag in this position because it forms a mobile link between the rigidly held thoracic spine and the sacrum and may cause the pelvis to tilt in the coronal plane, leading to malpositioning of the acetabular cup. To confirm this hypothesis, 10 consecutive patients seen in the preoperative assessment clinic had 2 anteroposterior radiographs taken in the lateral position. The area of exposure was from the lower thoracic spine to the sacrum. In the first radiograph, the lumbar spine was unsupported, and in the second, it was supported. The radiographs showed that the support did not make any significant difference to the position of the lumbar spine or to the position of the pelvis.

  17. Dual mobility bearings withstand loading from steeper cup-inclinations without substantial wear.

    PubMed

    Loving, LaQuawn; Herrera, Lizeth; Banerjee, Samik; Heffernan, Christopher; Nevelos, Jim; Markel, David C; Mont, Michael A

    2015-03-01

    Steep cup abduction angles with adverse joint loading may increase traditional polyethylene bearing wear in total hip arthroplasties. However, there have been few reports evaluating the effect of cup inclination on the wear of dual-mobility devices. In a hip joint simulation, we compared the short-term wear of two-sizes of modular highly cross-linked dual-mobility bearings (28 mm femoral head diameter/42 mm polyethylene insert outer diameter/54 mm acetabular shell diameter; 22.2 mm femoral head diameter/36 mm polyethylene insert outer diameter/48 mm acetabular shell diameter) at 50 and 65° of cup inclination with modular 28 mm femoral head on 54 mm cup diameter metal-on-highly cross-linked polyethylene bearings. Increasing inclination from 50-65° had no changes in volumetric wear of 28/42/54 mm (mean, 1.7 vs. 1.2 mm3 /million cycles, respectively; p = 0.50) and 22.2/36/48 mm (mean, 1.7 vs. 1.2 mm3/million cycles, respectively; p = 0.48) dual mobility bearings. At 65°, 22.2/36/48 mm dual-mobility bearings had lower volumetric loss (mean, 2.2 vs. 6.3 mm(3) ; p = 0.03) and wear rates (mean, 1.2 vs. 2.7 mm3/million cycles; p = 0.02) compared to metal-on-highly cross-linked polyethylene bearings. Modern-generation dual-mobility designs with highly cross-linked polyethylenes may potentially withstand edge-loading from steeper cup-inclinations without substantial decreases in wear.

  18. [Squeaking as a cause for revision of a composite ceramic cup].

    PubMed

    Schlegel, U J; Bishop, N; Sobottke, R; Perka, C; Eysel, P; Morlock, M M

    2011-09-01

    Squeaking in total hip arthroplasty (THA) has been observed only in hard-on-hard bearings, such as ceramic-on-ceramic or metal-on-metal. We report the case of a patient with a squeaking THA who had undergone multiple femoral head revisions combined with a composite ceramic cup (polyurethane, ceramic). Squeaking started 6 years postoperatively and acetabular revision was necessary to resolve the issue. Secondary deformation of the inlay resulted in clamping of the femoral head and increased friction. This should be considered when assessing and advising patients with squeaking THA when composite ceramic components are involved.

  19. Modified Faraday cup

    DOEpatents

    Elmer, J.W.; Teruya, A.T.; O`Brien, D.W.

    1996-09-10

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams is disclosed. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees from 0{degree} to 360{degree} and the waveforms are recorded by a digitizing storage oscilloscope. Two-dimensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment. 12 figs.

  20. Modified Faraday cup

    DOEpatents

    Elmer, John W.; Teruya, Alan T.; O'Brien, Dennis W.

    1996-01-01

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0.degree. to 360.degree. and the waveforms are recorded by a digitizing storage oscilloscope. Two-din-tensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment.

  1. Medium-term results of cementation of a highly cross-linked polyethylene liner into a well-fixed acetabular shell in revision hip arthroplasty.

    PubMed

    Lim, Seung-Jae; Lee, Keun-Ho; Park, Shin-Hyung; Park, Youn-Soo

    2014-03-01

    The present study was undertaken to document outcomes of cementation of a highly cross-linked polyethylene (PE) liner into a well-fixed acetabular metal shell in 36 hips. All operations were performed by a single surgeon using only one type of liner. Patients were followed for a mean of 6.1 years (range, 3-8 years). Mean Harris hip score improved from 58 points preoperatively to 91 points postoperatively. There were no cases of PE liner dislodgement or progressive osteolysis. 1 hip (2.8%) required revision surgery for acetabular cup loosening with greater trochanteric fracture. Complications included 1 peroneal nerve palsy and 1 dislocation. The results of this study and previous reports demonstrated that cementation of highly cross-linked PE liner into well-fixed metal shell could provide good midterm durability.

  2. Controversies in Treatment of Acetabular Fracture

    PubMed Central

    Grubor, Predrag; Krupic, Ferid; Biscevic, Mirza; Grubor, Milan

    2015-01-01

    Introduction: Acetabular fractures treatment represents a great controversy, challenge and dilemma for an orthopedic surgeon. Aim: The aim of the paper was to present the results of treatment of 96 acetabular fractures in the Clinic of Traumatology Banja Luka, in the period from 2003 to 2013, as well as to raise awareness regarding the controversy in the methods of choice in treating acetabulum fractures. Material and methods: The series consists of 96 patients, 82 males and 14 females, average age 40.5 years. Traffic trauma was the cause of fractures in 79 patients (85%), and in 17 patients (15%) fractures occurred due to falls from height. Polytrauma was present in 31 patients (32%). According to the classification of Judet and Letournel, representation of acetabular fractures was as follows: posterior wall in 32 patients, posterior column in 28, anterior wall in 4, anterior column in 2, transverse fractures in 8, posterior wall and posterior column in 10, anterior and posterior wall in 6, both- column in 4 and transversal fracture and posterior wall in 2 patients. 14 patients were treated with traction, that is, 6 patients with femoral traction and 8 patients with both lateral and femoral traction. 82 patients (86.4%) were surgically treated. Kocher-Langenbeck approach was applied in the treatment of 78 patients. In two patients from the Kocher-Langenbeck’s approach, the Ollier’s approach had to be applied as well. Two acetabular were primarily treated with Ollier’s approach. Extended Smith- Peterson’s approach was applied 4 times, and Emile Letournel’s (ilioinguinal) approach 14 times. Results: Functional outcome (after follow-up of 18 months), according to the Harris hip score of surgical treatment in 82 patients, was as follows: good 46 (56%), satisfactory 32 (39%) and poor 4 (5%). Results of acetabulum fractures treated with traction were: good 8 (57%), satisfactory 4 (28%) and poor 2 (15%). According to the Brook’s classification of heterotopic

  3. ION PRODUCING MECHANISM (CHARGE CUPS)

    DOEpatents

    Brobeck, W.W.

    1959-04-21

    The problems of confining a charge material in a calutron and uniformly distributing heat to the charge is described. The charge is held in a cup of thermally conductive material removably disposed within the charge chamber of the ion source block. A central thermally conducting stem is incorporated within the cup for conducting heat to the central portion of the charge contained within the cup.

  4. Gordon Bennett Airplane Cup

    NASA Technical Reports Server (NTRS)

    Margoulis, W

    1921-01-01

    The characteristics of the airplanes built for the Gordon Bennet Airplane Cup race that took place on September 28, 1920 are described. The airplanes are discussed from a aerodynamical point of view, with a number of new details concerning the French machines. Also discussed is the regulation of future races. The author argues that there should be no limitations on the power of the aircraft engines. He reasons that in the present state of things, liberty with regard to engine power does not lead to a search for the most powerful engine, but for one which is reliable and light, thus leading to progress.

  5. Sampling Bias on Cup Anemometer Mean Winds

    NASA Astrophysics Data System (ADS)

    Kristensen, L.; Hansen, O. F.; Højstrup, J.

    2003-10-01

    The cup anemometer signal can be sampled in several ways to obtain the mean wind speed. Here we discuss the sampling of series of mean wind speeds from consecutive rotor rotations, followed by unweighted and weighted averaging. It is shown that the unweighted averaging creates a positive bias on the long-term mean wind speed, which is at least one order of magnitude larger than the positive bias from the weighted averaging, also known as the sample-and-hold method. For a homogeneous, neutrally stratified flow the first biases are 1%-2%. For comparison the biases due to fluctuations of the three wind velocity components and due to calibration non-linearity are determined under the same conditions. The largest of these is the v-bias from direction fluctuations. The calculations pertain to the Risø P2546A model cup anemometer.

  6. Cup Cylindrical Waveguide Antenna

    NASA Technical Reports Server (NTRS)

    Acosta, Roberto J.; Darby, William G.; Kory, Carol L.; Lambert, Kevin M.; Breen, Daniel P.

    2008-01-01

    The cup cylindrical waveguide antenna (CCWA) is a short backfire microwave antenna capable of simultaneously supporting the transmission or reception of two distinct signals having opposite circular polarizations. Short backfire antennas are widely used in mobile/satellite communications, tracking, telemetry, and wireless local area networks because of their compactness and excellent radiation characteristics. A typical prior short backfire antenna contains a half-wavelength dipole excitation element for linear polarization or crossed half-wavelength dipole elements for circular polarization. In order to achieve simultaneous dual circular polarization, it would be necessary to integrate, into the antenna feed structure, a network of hybrid components, which would introduce significant losses. The CCWA embodies an alternate approach that entails relatively low losses and affords the additional advantage of compactness. The CCWA includes a circular cylindrical cup, a circular disk subreflector, and a circular waveguide that serves as the excitation element. The components that make it possible to obtain simultaneous dual circular polarization are integrated into the circular waveguide. These components are a sixpost polarizer and an orthomode transducer (OMT) with two orthogonal coaxial ports. The overall length of the OMT and polarizer (for the nominal middle design frequency of 2.25 GHz) is about 11 in. (approximately equal to 28 cm), whereas the length of a commercially available OMT and polarizer for the same frequency is about 32 in. (approximately equal to 81 cm).

  7. World Cup Hopes

    NASA Technical Reports Server (NTRS)

    2002-01-01

    From May 31 to June 30 the biggest single-sport event in the world, the 2002 FIFA World Cup (tm), will be taking place in Asia. South Korea and Japan are acting as hosts for the event which is being held in Asia for the first time. This true-color image of the southern Korean peninsula and southern Japan was acquired on May 25, 2002, by the Moderate-resolution Imaging Spectroradiometer (MODIS), flying aboard NASA's Terra satellite. Thirty-two nations are represented at this year's Finals including the 1998 champion France, European powers England and Italy, tournament favorite Argentina, and the United States. The finals are the culmination of a 2-year qualifying process which started with 132 nations competing in regional qualification tournaments. In the round-robin first round of the World Cup, the U.S. team will be competing against teams from Portugal, Poland, and South Korea. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC

  8. Welding torch gas cup extension

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S. (Inventor)

    1988-01-01

    The invention relates to a gas shielded electric arc welding torch having a detachable gas cup extension which may be of any desired configuration or length. The gas cup extension assembly is mounted on a standard electric welding torch gas cup to enable welding in areas with limited access. The gas cup assembly has an upper tubular insert that fits within the gas cup such that its lower portion protrudes thereform and has a lower tubular extension that is screwed into the lower portion. The extension has a rim to define the outer perimeter of the seat edge about its entrance opening so a gasket may be placed to effect an airtight seal between the gas cup and extension. The tubular extension may be made of metal or cermaic material that can be machined. The novelty lies in the use of an extension assembly for a standard gas cup of an electric arc welding torch which extension assembly is detachable permitting the use of a number of extensions which may be of different configurations and materials and yet fit the standard gas cup.

  9. Acetabular Fractures in the Elderly: Treatment Recommendations

    PubMed Central

    Pagenkopf, Eric; Grose, Andrew; Partal, George

    2006-01-01

    Acetabular fractures in the elderly population are marked by a high degree of variability in terms of patient and fracture characteristics. Successful outcomes depend on application of highly individualized management principles by experienced teams. Reviewed are indications and outcomes associated with various management options, including closed treatment, open reduction internal fixation, and acute or staged total hip arthroplasty. Proper initial management choices are critical, as early failures and subsequent salvage surgery can be accompanied by significant morbidity. Clinical results after ORIF closely follow the quality of articular reduction and the ability to maintain a congruent reduction of the hip joint. Fracture characteristics predictive of anatomic articular reduction should be treated with ORIF. Fracture characteristics predictive of early post-traumatic arthritis should be treated with simultaneous ORIF and THA. Presented is one referral institution’s treatment algorithm and management approach. PMID:18751831

  10. Wear of highly crosslinked polyethylene acetabular components

    PubMed Central

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Munn, Zachary; Howie, Donald W

    2015-01-01

    Background and purpose Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). Methods A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). Results 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2–10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. Interpretation This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear. PMID:25301435

  11. Cementation of an acetabular liner into a well-fixed acetabular shell during revision total hip arthroplasty.

    PubMed

    Springer, Bryan D; Hanssen, Arlen D; Lewallen, David G

    2003-10-01

    Cementing a polyethylene liner into a well-fixed acetabular shell during revision hip arthroplasty may be appropriate in select patients. The purpose of this study was to review our early results with this technique. Sixteen patients with >2-year follow-up or who had any complications at <2 years from surgery were identified. Indications for this technique included: failure of the previous locking mechanism, significant polyethylene wear, malposition of the well-fixed metal shell, and previous removal of the liner with a retained acetabular shell. One acetabular shell has been revised at 13 months for multiple dislocations. Hip scores improved an average of 24.2 points. Radiographs revealed no polyethylene dissociation or acetabular loosening. Complications occurred in 7 patients. Initial results appear successful at providing secure fixation, while preventing the bone loss that might occur with removal of a well-fixed component.

  12. Optic atrophy and glaucomatous cupping.

    PubMed

    Radius, R L; Maumenee, A E

    1978-02-01

    We reviewed 170 eyes of 112 patients with optic atrophy from various causes. Special attention was directed towards measured cup:disk ratios as well as presence of glaucomatous-like cupping of the optic nerve head. We observed a small but significant increase in nerve head cupping in eyes with optic atrophy when compared to contralateral eyes, as well as to eyes of 50 diabetic patients. No characteristic glaucomatous disk changes were documented. We evaluated these findings with respect to possible causes of glaucomatous disk and field changes.

  13. On Cup Anemometer Rotor Aerodynamics

    PubMed Central

    Pindado, Santiago; Pérez, Javier; Avila-Sanchez, Sergio

    2012-01-01

    The influence of anemometer rotor shape parameters, such as the cups' front area or their center rotation radius on the anemometer's performance was analyzed. This analysis was based on calibrations performed on two different anemometers (one based on magnet system output signal, and the other one based on an opto-electronic system output signal), tested with 21 different rotors. The results were compared to the ones resulting from classical analytical models. The results clearly showed a linear dependency of both calibration constants, the slope and the offset, on the cups' center rotation radius, the influence of the front area of the cups also being observed. The analytical model of Kondo et al. was proved to be accurate if it is based on precise data related to the aerodynamic behavior of a rotor's cup. PMID:22778638

  14. On cup anemometer rotor aerodynamics.

    PubMed

    Pindado, Santiago; Pérez, Javier; Avila-Sanchez, Sergio

    2012-01-01

    The influence of anemometer rotor shape parameters, such as the cups' front area or their center rotation radius on the anemometer's performance was analyzed. This analysis was based on calibrations performed on two different anemometers (one based on magnet system output signal, and the other one based on an opto-electronic system output signal), tested with 21 different rotors. The results were compared to the ones resulting from classical analytical models. The results clearly showed a linear dependency of both calibration constants, the slope and the offset, on the cups' center rotation radius, the influence of the front area of the cups also being observed. The analytical model of Kondo et al. was proved to be accurate if it is based on precise data related to the aerodynamic behavior of a rotor's cup.

  15. Aerodynamic characteristics of anemometer cups

    NASA Technical Reports Server (NTRS)

    Brevoort, M J; Joyner, U T

    1934-01-01

    The static lift and drag forces on three hemispherical and two conical cups were measured over a range of angles of attack from 0 degrees to 180 degrees and a range of Reynolds Numbers from very small up to 400,000. The problems of supporting the cup for measurement and the effect of turbulence were also studied. The results were compared with those of other investigators.

  16. Comparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty

    PubMed Central

    Jo, Woo-Lam; Im, Jin-Hyung; Kim, Seung-Chan; Kwon, Soon-Yong; Kim, Yong-Sik

    2017-01-01

    Purpose It is challenging procedure to revise acetabular component in acetabulum with severe bone defect or deformity. The jumbo cup is good option for revisional arthroplasty in large bone defect. The purpose of this study is to compare the prognosis of revisional total hip arthroplasty using jumbo cup with peripheral rim fixation and no rim fixation. Materials and Methods We included the patients who had performed acetabular revisional total hip arthroplasty from January 2002 to March 2015 in our institute. Total of 51 hips (51 patients) were included. The mean follow up period was 51 months (range, 12 to 154 months) and mean age was 60.7 years (range, 30 to 81 years). We divided into two groups (peripheral rim fixation group and no rim fixation group) by anteroposterior and lateral plain radiograph. We compared survival rate, hip center change and clinical outcomes between two groups. Results There were 37 patients in peripheral rim fixation group and 14 patients in no rim fixation group. There was one patient who had aseptic loosening necessary to re-revision in rim fixation group and 3 patients in no rim fixation group. And one patient had superficial infection in rim fixation group and one patient had periprosthetic fracture in no rim fixation group. Survival rate was higher in the peripheral rim fixation group (97.3%) than no rim fixation group (78.6%, P=0.028) Conclusion Based on our findings, peripheral rim fixation might be recommended to improve short-term outcome after revision total hip arthroplasty using jumbo cup. PMID:28316959

  17. Preliminary Biomechanical Study of Different Acetabular Reinforcement Devices for Acetabular Reconstruction

    PubMed Central

    Tai, Ching-Lung; Lee, Po-Yi; Hsieh, Pang-Hsing

    2015-01-01

    Background Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct. However, all commercially available ARDs are designed with non-locking fixation. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction. Methods Three types of ARDs were examined to evaluate the postoperative compression and angular stability: i) standard commercial ARDs, ii) standard ARDs modified with monoaxial and iii) standard ARDs modified with polyaxial locking screw mechanisms. All ARDs were implanted into osteomized synthetic pelvis with pelvic discontinuity. Axial compression and torsion tests were then performed using a servohydraulic material testing machine that measured load (angle) versus displacement (torque). Initial stability was compared among the groups. Results Equipping ARDs with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs. In both compression and torsion experiments, the monoaxial interlocking construct demonstrated the highest construct stiffness (672.6 ± 84.1 N/mm in compression and 13.3 ± 1.0 N·m/degree in torsion), whereas the non-locked construct had the lowest construct stiffness (381.4 ± 117.2 N/mm in compression and 6.9 ± 2.1 N·m/degree in torsion) (P < 0.05). Conclusions Our study demonstrates the potential benefit of adding a locking mechanism to an ARD. Polyaxial ARDs provide the surgeon with more flexibility in placing the screws at the cost of reduced mechanical performance. This in vitro study provides a preliminary evaluation of biomechanical performance for ARDs

  18. Arthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note

    PubMed Central

    Park, Jin young; Kim, Che Keun; Huh, Soon Ho; Kim, Se Jin; Jung, Bo Hyun

    2016-01-01

    Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report our case with technical note. PMID:27536654

  19. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip...

  20. Spoon-to-Cup Fading as Treatment for Cup Drinking in a Child with Intestinal Failure

    ERIC Educational Resources Information Center

    Groff, Rebecca A.; Piazza, Cathleen C.; Zeleny, Jason R.; Dempsey, Jack R.

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup. (Contains 2…

  1. Long-Term Outcome of Acetabular Reconstruction Using a Kerboull-Type Acetabular Reinforcement Device with Hydroxyapetite Granule and Structural Autograft for AAOS type II and III Acetabular Defects.

    PubMed

    Kim, Youngwoo; Tanaka, Chiaki; Kanoe, Hiroshi

    2015-10-01

    We evaluated the clinical results of the reconstruction of acetabular bone deficiency using hydroxyapatite (HA) granules and structural autografts supported by a Kerboull-type acetabular reinforcement device at a minimum of 10 years follow-up. Between 1993 and 2003, 40 consecutive THA revisions were performed in 37 patients with a mean age of 66.4 years. The mean follow-up period was 12.8 years. Radiologically, 5 hips failed, of which 2 were revised. The survival rate of the acetabular component at 10 years was 100% in type II defects and 94.9% in the type III defects, using acetabular revision for loosening as the end point. Acetabular reconstruction with HA granules, structural autografts and a Kerboull-type acetabular reinforcement device provided satisfactory clinical and radiological results at 12.8 years postoperatively.

  2. A Novel Approach for Treatment of Acetabular Fractures

    PubMed Central

    Xue, Zichao; Qin, Hui; Ding, Haoliang; An, Zhiquan

    2016-01-01

    Background There is no single approach that provides adequate exposure for treatment of all types of acetabular fractures. We describe our experience with an easier, relatively less invasive pubic symphysis approach (PSA) for the treatment of acetabular fractures. Material/Methods Between March 2011 and March 2012, fifteen patients with acetabular fracture underwent surgery using the PSA technique. Fracture reduction and treatment outcomes were assessed by clinical and radiological examination. Operation time, intraoperative blood loss and postoperative complications were documented. Results Mean operative time was 222±78 minutes. Average blood loss was 993±361 mL. Anatomical reduction was achieved in all patients. Minimum follow-up period was 31 months. Postoperative hypoesthesia in the area of innervation of the lateral femoral cutaneous nerve was reported in one patient, with spontaneous recovery at one month after surgery. No complications were reported during the follow-up period. At the most recent follow up, clinical outcomes were graded as “excellent” in six patients, “good” in eight patients and “fair” in one patient based on the modified Merle d’Aubigné-Postel score. Conclusions PSA appears to be a timesaving and safe approach for treatment of acetabular fractures that affords good visual access and allows for excellent fracture reduction. Our preliminary results revealed a much lower incidence of complications than traditional approaches, suggesting PSA is an alternative for treatment of acetabular fractures. PMID:27734825

  3. World Cup Final

    NASA Technical Reports Server (NTRS)

    2006-01-01

    On July 9, hundreds of millions of fans worldwide will be glued to their television sets watching the final match of the 2006 FIFA World Cup, played in Berlin's Olympic stadium (Olympiastadion). The stadium was originally built for the 1936 Summer Olympics. The Olympic Stadium seats 76,000,; its roof rises 68 meters over the seats and is made up of transparent panels that allow sunlight to stream in during the day.

    With its 14 spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters (about 50 to 300 feet), ASTER images Earth to map and monitor the changing surface of our planet.

    ASTER is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of Economy, Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products.

    The broad spectral coverage and high spectral resolution of ASTER provides scientists in numerous disciplines with critical information for surface mapping, and monitoring of dynamic conditions and temporal change. Example applications are: monitoring glacial advances and retreats; monitoring potentially active volcanoes; identifying crop stress; determining cloud morphology and physical properties; wetlands evaluation; thermal pollution monitoring; coral reef degradation; surface temperature mapping of soils and geology; and measuring surface heat balance.

    The U.S. science team is located at NASA's Jet Propulsion Laboratory, Pasadena, Calif. The Terra mission is part of NASA's Science Mission Directorate.

    Size: 12.1 by 15.9 kilometers (7.5 by 9.5 miles) Location: 52.5 degrees North latitude, 13.3 degrees East longitude Orientation: North at top Image Data: ASTER bands 3, 2, and 1 Original Data Resolution: 15 meters (49.2 feet) Dates Acquired: October 15, 2005

  4. Three Year RSA Evaluation of Vitamin E Diffused Highly Cross-linked Polyethylene Liners and Cup Stability.

    PubMed

    Sillesen, Nanna H; Greene, Meridith E; Nebergall, Audrey K; Nielsen, Poul T; Laursen, Mogens B; Troelsen, Anders; Malchau, Henrik

    2015-07-01

    Vitamin E diffusion into highly cross-linked polyethylene (E-XLPE) is a method for enhancing oxidative stability of acetabular liners. The purpose of this study was to evaluate in vivo penetration of E-XLPE using radiostereometric analysis (RSA). Eighty-four hips were recruited into a prospective 10-year RSA. This is the first evaluation of the multicenter cohort after 3-years. All patients received E-XLPE liners (E1, Biomet) and porous-titanium coated cups (Regenerex, Biomet). There was no difference (P=0.450) in median femoral head penetration into the E-XLPE liners at 3-years comparing cobalt-chrome heads (-0.028mm; inter-quartile range (IQR) - 0.065 to 0.047) with ceramic heads (-0.043mm, IQR - 0.143to0.042). The 3-year follow-up indicates minimal E-XLPE liner penetration regardless of head material and minimal early cup movement.

  5. Tension band stabilisation of acetabular physeal fractures in four kittens.

    PubMed

    Langley-Hobbs, S J; Sissener, T R; Shales, C J

    2007-06-01

    The surgical repair of acetabular physeal fractures in four kittens using a screw and tension band technique is reported. This was an appropriate method for restoring articular congruency and improving pelvic alignment. All cases had an excellent outcome and full limb use following fracture repair. In kittens younger than 12 weeks, there is a possibility of premature fusion of the acetabular bone resulting in development of a deformed, shallow acetabulum and hip subluxation. However, surgery is still justified when there is pelvic canal narrowing to decrease the risk of future defecatory problems. Early implant removal in such young kittens may decrease the severity of deformity caused by premature physeal closure. In kittens of 16 weeks or older, the prognosis is good for normal acetabular development and implant removal is not necessary.

  6. Versatile, high-sensitivity faraday cup array for ion implanters

    DOEpatents

    Musket, Ronald G.; Patterson, Robert G.

    2003-01-01

    An improved Faraday cup array for determining the dose of ions delivered to a substrate during ion implantation and for monitoring the uniformity of the dose delivered to the substrate. The improved Faraday cup array incorporates a variable size ion beam aperture by changing only an insertable plate that defines the aperture without changing the position of the Faraday cups which are positioned for the operation of the largest ion beam aperture. The design enables the dose sensitivity range, typically 10.sup.11 -10.sup.18 ions/cm.sup.2 to be extended to below 10.sup.6 ions/cm.sup.2. The insertable plate/aperture arrangement is structurally simple and enables scaling to aperture areas between <1 cm.sup.2 and >750 cm.sup.2, and enables ultra-high vacuum (UHV) applications by incorporation of UHV-compatible materials.

  7. Development of site-specific locking plates for acetabular fractures.

    PubMed

    Xu, Meng; Zhang, Li-Hai; Zhang, Ying-Ze; He, Chun-Qing; Zhang, Li-Cheng; Wang, Yan; Tang, Pei-Fu

    2013-05-01

    Site-specific locking plates have gained popularity for the treatment of fractures. However, the clinical use of a site-specific locking plate for acetabular fractures remains untested due to production limits. To design a universal site-specific locking plate for acetabular fractures, the 3-dimensional (3D) photographic records of 171 pelvises were retrospectively studied to generate a universal posterior innominate bone surface. Using 3D photographical processing software, the 3D coordinate system was reset according to bony landmarks and was scaled based on the acetabular diameter to allow a direct comparison between surfaces. The measured surface was separated into measurement units. At each measurement unit, the authors calculated the average z-axis values in all samples and obtained the 3D coordinate values of the point cloud that could be reconstructed into the universal surface. A plate was subsequently designed in 3D photographical processing software, and the orientation and distribution of locking screws was included. To manufacture a plate, the data were entered into Unigraphics NX version 6.0 software (Siemens PLM Software, Co, Ltd, Plano, Texas) and a CNC digital milling machine (FANUC Co, Ltd, Yamanashi, Japan). The resulting locking plate fit excellently with the reduced bone surface intraoperatively. Plate contouring was avoided intraoperatively. Universal 3.5-mm locking screws locked successfully into the plate, and their orientations were consistent with the design. No screw yielded to acetabular penetration. This method of designing a site-specific acetabular locking plate is practical, and the plates are suitable for clinical use. These site-specific locking plates may be an option for the treatment of acetabular fractures, particularly in elderly patients.

  8. Surgical treatment of an acetabular fracture and labral tear with suture anchors in a 10-year-old child.

    PubMed

    Mormor, Meir; Matityahu, Amir

    2009-11-01

    This article presents a case of a 10-year-old boy with a right acetabular fracture secondary to a direct blow to the pelvis and back. He sustained a right hip dislocation and transverse with posterior wall acetabular fracture with a nonconcentric hip joint after reduction. The fracture was treated with right labral and articular segment absorbable suture tie-down and relocation of the right hip into an anatomical position. At 32-month follow-up, the patient had returned to activities of daily living, he had a normal and symmetric gait pattern, and no pain on hip adduction, flexion, or internal rotation. This technique reduced the fracture and labrum, relocated the hip joint, and obviated the need for hardware removal that is typically needed in the pediatric population. This case is distinctive due to the patient's young age and treatment method, which has not been described previously for the treatment of this rare pediatric fracture.

  9. Canted seating of the Stryker Modular Dual Mobility liner within a Trident hemispherical acetabular shell.

    PubMed

    Eskildsen, Scott M; Olsson, Erik C; Del Gaizo, Daniel J

    2016-03-01

    A 75-year-old woman who suffered a left femoral neck fracture underwent a left total hip arthroplasty using a Stryker Trident (Kalamazoo, MI) hemispherical acetabular shell and Modular Dual Mobility (MDM) metal liner. Post-operative radiographs demonstrated canted seating of the liner. The patient was taken immediately back to the operating room where the acetabular liner appeared well seated superiorly but was in a canted position inferiorly. Removal and replacement was performed and post-operative radiographs demonstrated complete seating. Subsequent follow up at 6 months demonstrated good clinical function with no adverse radiographic findings. Canted seating is a potential complication of the MDM metal liner. Providers should be aware of potential incomplete seating inferiorly despite the superior portion of the liner being well seated.

  10. Aerodynamic Investigation of a Cup Anemometer

    NASA Technical Reports Server (NTRS)

    Hubbard, John D; Brescoll, George P

    1934-01-01

    This thesis presents the results of an investigation wherein the change of the normal force coefficient with Reynolds Number was obtained statically for a 15.5-centimeter hemisphere cup under the following conditions: (1) single cup with no interference; (2) single cup with three-cup interference; (3) four cups. The coefficients found in this research vary with Reynolds Number and are high as compared with those of Eiffel. The effect of interference upon a single cup is to increase the drag and normal force coefficients. The curve resulting from the summation of the coefficients for four cups agrees with the static torque curve of a Robinson type cup anemometer. All tests were carried on in the University of Detroit atmospheric wind tunnel during May 1933.

  11. Dummy Cup Helps Robot-Welder Programmers

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S.

    1990-01-01

    Dummy gas cup used on torch of robotic welder during programming and practice runs. Made of metal or plastic, dummy cup inexpensive and durable. Withstands bumps caused by programming errors, and is sized for special welding jobs within limited clearances. After robot satisfactorily programmed, replaced by ceramic cup of same dimensions for actual welding.

  12. Coffee Cup Atomic Force Microscopy

    ERIC Educational Resources Information Center

    Ashkenaz, David E.; Hall, W. Paige; Haynes, Christy L.; Hicks, Erin M.; McFarland, Adam D.; Sherry, Leif J.; Stuart, Douglas A.; Wheeler, Korin E.; Yonzon, Chanda R.; Zhao, Jing; Godwin, Hilary A.; Van Duyne, Richard P.

    2010-01-01

    In this activity, students use a model created from a coffee cup or cardstock cutout to explore the working principle of an atomic force microscope (AFM). Students manipulate a model of an AFM, using it to examine various objects to retrieve topographic data and then graph and interpret results. The students observe that movement of the AFM…

  13. VALIDATION OF FE MICROMOTIONS AND STRAINS AROUND A PRESS-FIT CUP: INTRODUCING A NEW MICROMOTION MEASURING TECHNIQUE

    PubMed Central

    Clarke, S G; Phillips, A T M; Bull, A M J

    2014-01-01

    Finite element analysis provides a useful tool with which to analyse the potential performance of implantations in a variety of surgical, patient and design scenarios. To enable the use of finite element analysis in the investigation of such implants, models must be experimentally validated. Validation of a pelvic model with an implanted press-fit cup in terms of micromotion and strain is presented here. A new method of micromotion has been introduced to better describe the overall movement of the cup within the pelvis. The method uses a digitizing arm to monitor the relative movement between markers on the cup and the surrounding acetabulum. Finite element analysis was used to replicate an experimental set up using a synthetic hemi-pelvis with a press-fitted all-metal cup was subject to the maximum loading observed during normal walking. The work presented here has confirmed the ability of finite element models to accurately describe the mechanical performance of the press-fitted acetabulum and surrounding bone under typical loading conditions in terms of micromotion and strain distribution, but has demonstrated limitations in its ability to predict numerical micromotion values. A promising digitizing technique for measuring acetabular micromotions has also been introduced. PMID:22350664

  14. Cementless acetabular fixation in patients 50 years and younger at 10 to 18 years of follow-up.

    PubMed

    Teusink, Matthew J; Callaghan, John J; Warth, Lucian C; Goetz, Devon D; Pedersen, Douglas R; Johnston, Richard C

    2012-08-01

    The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.

  15. Lateral acetabular labral length is inversely related to acetabular coverage as measured by lateral center edge angle of Wiberg

    PubMed Central

    Petersen, Brian D.; Wolf, Bryan; Lambert, Jeffrey R.; Clayton, Carolyn W.; Glueck, Deborah H.; Jesse, Mary Kristen; Mei-Dan, Omer

    2016-01-01

    Patients with developmental dysplasia of the hip often have compensatory labral hypertrophy, which presumably lends stability to an unstable joint. Conversely, patients with acetabular overcoverage may have small or ossified labra. The purpose of this study is to explore the interaction of labral length with the degree of acetabular hip coverage. A retrospective cohort of patients with hip pain presenting to a hip preservation center, who had undergone hip magnetic resonance imaging and AP pelvis radiographs were studied. General linear multivariate models were used to assess the association between three measures of labral length (lateral, anterior and anterior inferior locations along the acetabular rim) and the X-ray derived lateral center edge angle (LCEA) of Wiberg. Of the three acetabular labral locations measured, only the lateral labrum was associated with LCEA Wiberg (P = 0.0008). Lateral labral length increases as LCEA of Wiberg decreases. The anterior and anterior inferior labral locations did not show a predictable increase in labral length as LCEA Wiberg decreased. PMID:27583157

  16. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    PubMed

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  17. Experimental Investigation of the Robinson-Type Cup Anemometer

    NASA Technical Reports Server (NTRS)

    Brevoort, M J; Joyner, U T

    1936-01-01

    This report presents the results of wind tunnel tests on a Robinson-type anemometer. The investigation covered force measurements on individual cups, as well as static and dynamic torque measurements and calibrations on complete cup wheels. In the tests on individual cups 5 cup forms were used and in the measurements on complete cup wheels 4 cup wheels with 3 arm lengths for each cup wheel were tested. All the results are presented in graphical form.

  18. Significant and sustaining elevation of blood oxygen induced by Chinese cupping therapy as assessed by near-infrared spectroscopy

    PubMed Central

    Li, Ting; Li, Yaoxian; Lin, Yu; Li, Kai

    2016-01-01

    Cupping therapy has been used in traditional Chinese medicine for thousands of years to relieve muscle pain/tendency/fatigue and to cure or reduce symbols of other diseases. However, its therapeutic effect is sparsely interpreted in the language of modern physiology. To objectively evaluate its therapeutic effect, we focused on dry cupping treatment and utilized near-infrared spectroscopy (NIRS) to assess the concentration change in oxy-hemoglobin ([HbO2]), deoxy-hemoglobin ([Hb]), and blood volume in the course of cupping therapy over 13 volunteers on the infraspinatus muscle, where is usually applied for shoulder pains. Both a prominent drop in [Hb] and a significant elevation in [HbO2] in the tissue surrounding the cupping site were observed during both cupping and post-treatment, manifesting the enhancement of oxygen uptake. This resulting promotion indicates potential positive therapeutic effect of cupping therapy in hemodynamics for facilitating muscular functions. PMID:28101413

  19. Multiobjective optimization of an electrostimulative acetabular revision system.

    PubMed

    Potratz, Carsten; Kluess, Daniel; Ewald, Hartmut; van Rienen, Ursula

    2010-02-01

    In this paper, we present a new approach for the enhancement of the bone proliferation rate by electrostimulation in the acetabular region. Based on the complex tissue structure in this area, the electric field distributions were computed by numerical means using a model based on high-resolution computed tomography scans of the acetabular area. This results in a complex, nonlinear, and discrete optimization problem. Therefore, an adapted algorithm was developed to reduce the computational effort in the order of several magnitudes. We divided the procedure into two stages: data extraction and a subsequent optimization process. The used optimization algorithm utilizes an evolutionary concept and a multidimensional definition of optimality for different, partly contradictive objective functions. Finally, we present first optimization results for different stimulation situations.

  20. Para-acetabular periarthritis calcarea: its radiographic manifestations.

    PubMed

    Kawashima, A; Murayama, S; Ohuchida, T; Russell, W J

    1988-01-01

    On retrospective reviews of radiographs, periarthritis calcarea was distinguished from os acetabula by interval radiographic progression and regression. Among 59 men and 51 women, there were 137 instances of para-acetabular calcifications and ossifications, which were morphologically classified as 58 discrete, 58 amorphous, and 21 segmented types. Correlations with other radiographic abnormalities, symptoms, signs, and laboratory abnormalities were sought, but not established. Out of 93 serially imaged opacities, 90 changed, including 37 of the 40 instances (92.5%) of the discrete type and 53 instances (100%) of the amorphous and segmented types--due to periarthritis calcarea. At least 43 of 90 densities were newly developed. Mean age at first detection was 47.7 years. Three of the discrete densities were unchanged and represented os acetabula. Thus, recognition of para-acetabular periarthritis calcarea is not only of academic importance; it can facilitate proper treatment as well.

  1. Late sciatic nerve axonotmesis following acetabular reconstruction plate.

    PubMed

    Moreta, J; Foruria, X; Labayru, F

    2016-01-01

    Sciatic nerve injuries associated with acetabular fractures can be post-traumatic, perioperative or postoperative. Late postoperative injury is very uncommon and can be due to heterotopic ossifications, muscular scarring, or implant migration. A case is presented of a patient with a previous transverse acetabular fracture treated with a reconstruction plate for the posterior column. After 17 years, she presented with progressive pain and motor deficit in the sciatic territory. Radiological and neurophysiological assessments were performed and the patient underwent surgical decompression of the sciatic nerve. A transection of the nerve was observed that was due to extended compression of one of the screws. At 4 years postoperatively, her pain had substantially diminished and the paresthesias in her leg had resolved. However, her motor symptoms did not improve. This case report could be relevant due to this uncommon delayed sciatic nerve injury due to prolonged hardware impingement.

  2. Acetabular augmentation for the treatment of unstable total hip arthroplasties.

    PubMed Central

    Nicholl, J. E.; Koka, S. R.; Bintcliffe, I. W.; Addison, A. K.

    1999-01-01

    Twenty-eight unstable total hip arthroplasties were treated with an acetabular augmentation wedge. Of the hips, 23 have had no further dislocations at a mean follow-up of 26 months. Five patients continued to dislocate and have needed further surgery. To our knowledge this is the largest reported series of acetabular augmentation with as good results as those of the most successful reported series of this technique, and a success rate comparable to other methods of treating recurrent dislocation. Careful patient selection, and using a thin augmentation wedge to avoid impingement, are important to the success of a technique which is a useful option in the management of recurrent dislocation. Images Figure 1 PMID:10364973

  3. Acetabular revision with freeze-dried irradiated and chemically treated allograft: a minimum 5-year follow-up of 17 cases

    PubMed Central

    Caton, Jacques

    2007-01-01

    We reviewed the results of 17 consecutive revision total hip arthroplasties performed with the use of freeze-dried irradiated bone allograft in 15 patients. These allografts were used in conjunction with five Kerboull rings, two steel meshes and ten cemented isolated cups. All the patients have had a follow-up of at least 5 years. The patients were evaluated clinically and radiographically. No revisions were necessary and X-rays confirmed partial or total ingrowth of the allografts. In acetabular revision surgery, hip reconstruction can be successfully treated by freeze-dried irradiated and chemically treated allografts. Additional studies with longer term follow-up are necessary to confirm this outcome. PMID:17828537

  4. Lamp with a truncated reflector cup

    DOEpatents

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  5. Evaluation of the NexScreen and DrugCheck Waive RT urine drug detection cups.

    PubMed

    Lin, Chia-Ni; Nelson, Gordon J; McMillin, Gwendolyn A

    2013-01-01

    Urine drug testing is an important tool that is commonly used to assess patient compliance with prescription regimens. Point-of-collection immunoassay devices allow for timely availability of laboratory test results to guide therapy during the same office visit. Two waived immunoassay-based urine drug screen cups were evaluated in this study. The NexScreen cup and the DrugCheck Waive RT cup claim to detect 10-12 drug classes of commonly used and/or abused drugs. This study included a sensitivity and precision challenge with 4-6 replicates at concentrations 0-150% of the manufacture's claimed cutoff, using drug-free urine spiked with purified reference standards. The stability of test results was evaluated by reading the results at intervals between five and 1,440 min. Specificity was evaluated by parallel comparison of pooled patients' specimens, representing 56 patients and 41 known drug compounds. When comparing results to validated liquid chromatography-mass spectrometry results, false positives were observed in the NexScreen cups for benzodiazepine, methamphetamine, methadone, opiates and tricyclic antidepressant tests, but there were no false negatives. The DrugCheck Waive RT cups showed false negative results for barbiturates and opiates, but no false positives. Overall, the NexScreen cup demonstrated better sensitivity than claimed, whereas the sensitivity of the DrugCheck Waive RT cup did not meet claims.

  6. The Use of Iliac Stem Prosthesis for Acetabular Defects following Resections for Periacetabular Tumors

    PubMed Central

    De Paolis, Massimiliano; Romagnoli, Carlo; Alì, Nikolin; Giannini, Sandro; Donati, Davide Maria

    2013-01-01

    Introduction. The management of pelvic tumors is a challenge for orthopaedic oncologists due to the complex anatomy of the pelvis and the need to have extensive exposure. Various reconstructive techniques have been proposed with poor functional results and a high percentage of complications. Our purpose is to determine the functional results and the rate of complications of iliac stem prosthesis for acetabular defects following resections for periacetabular tumors. Materials and Methods. Between 1999 and 2012, 45 patients underwent pelvic resections for periacetabular bone tumors followed by reconstruction with stem cup prosthesis. The most common diagnosis was CS (chondrosarcoma, 29 cases), followed by OS (osteosarcoma, 9 cases) and metastasis (3 cases). In 33 cases, this implant was associated with massive bone allografts. Minimum follow-up required to evaluate functional outcome was 2 years. We classified pelvic resections according to Enneking and Dunham's classification and we used MSTS (musculoskeletal tumor system) score to evaluate functional outcomes. Results and Discussion. Sixteen patients died of their disease, three were lost to follow-up, four are alive with disease, and twenty-two are alive with no evidence of disease. Fifteen patients had local recurrence. Sixteen patients had bone or lung metastasis. We have had 6 infections, 2 aseptic loosening, and 2 cases of hip dislocation. Iliac sovracetabular osteotomy was fused in all cases at 10 months from surgery. Functional results were good or excellent in 25 of 31 patients with long-term follow-up (77%), with a percentage similar to that reported in the literature. Conclusion. The use of iliac stem prosthesis is a simple reconstructive technique that reduces operative times and risk of infection. It allows having good results and low rate of complications, but it should be performed in selected cases and centres of reference. PMID:24250275

  7. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  8. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  9. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  10. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  11. Microbiological and physical quality changes in vacuum loader cups associated with the use of various sanitizing compounds.

    PubMed

    Jones, D R

    2010-03-01

    Studies were conducted to determine the effects of various sanitizing compounds on the microbial and physical quality of shell egg processing vacuum loader cups. The sanitizing compounds used were as follows: sterile, distilled water; 200 microL/L of sodium hypochlorite; 200 microL/L of calcium hypochlorite; and 200 microL/L of peracetic acid. In the microbial inoculation study, cups were inoculated with Enterobacter cloacae because it was the most common isolate from a commercial study examining the flora found on vacuum loader cups. In all 3 replicates, aerobic plate counts and Enterobacteriaceae levels were similar for the clean control cups and the cups from the 2 chlorine treatments. Physical quality was measured via serial static compression testing using texture profile analysis. The serial compression mimicked the movement of the vacuum loader cups on the processing line. The strength of the vacuum loader cups was enhanced with exposure to any sanitizer treatment, including distilled water, compared with the controls throughout the 20 applications of the sanitizers. Durometer measurements were not consistent in monitoring vacuum loader cup quality and were determined to not be effective assessments for this application. The use of 200 microL/L of sodium hypochlorite or 200 microL/L of calcium hypochlorite successfully reduced microbial contaminants, had a positive effect on vacuum loader cup physical quality, and should be considered when developing sanitation programs for shell egg processing facilities.

  12. Cheaper Custom Shielding Cups For Arc Welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.

    1992-01-01

    New way of making special-purpose shielding cups for gas/tungsten arc welding from hobby ceramic greatly reduces cost. Pattern machined in plastic. Plaster-of-paris mold made, and liquid ceramic poured into mold. Cost 90 percent less than cup machined from lava rock.

  13. Fourier analysis of the aerodynamic behavior of cup anemometers

    NASA Astrophysics Data System (ADS)

    Pindado, Santiago; Pérez, Imanol; Aguado, Maite

    2013-06-01

    The calibration results (the transfer function) of an anemometer equipped with several cup rotors were analyzed and correlated with the aerodynamic forces measured on the isolated cups in a wind tunnel. The correlation was based on a Fourier analysis of the normal-to-the-cup aerodynamic force. Three different cup shapes were studied: typical conical cups, elliptical cups and porous cups (conical-truncated shape). Results indicated a good correlation between the anemometer factor, K, and the ratio between the first two coefficients in the Fourier series decomposition of the normal-to-the-cup aerodynamic force.

  14. [Protrusio acetabuli. An update on the primary and secondary acetabular protrusion].

    PubMed

    Kindynis, P; Garcia, J

    1990-01-01

    Acetabular protrusion refers to intrapelvic displacement of the medial wall of the acetabulum and is defined as inward movement of the acetabular line so that the distance between this line and the laterally located ilioischial line is 3 mm or more in adult men and 6 mm or more in adult women. As discussed in this article, acetabular protrusion may be found in many bone disorders such as degenerative joint disease, Paget's disease, rheumatoid arthritis, ankylosing spondylitis, osteomalacia, Marfan's disease and as an effect of irradiation. Protrusio acetabuli appearing in absence of any recognizable cause is termed primary acetabular protrusion or Otto pelvis. Primary acetabular protrusion usually affects both hips in young to middle aged women with a history of diminished abduction, rotation and hip pain since puberty. Radiographically one notes a bilateral axial migration of the femoral head without joint space loss and with moderate degenerative changes.

  15. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    PubMed

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction.

  16. Three-dimensional acetabular orientation measurement in a reliable coordinate system among one hundred Chinese

    PubMed Central

    Zhang, Henghui; Wang, Yiping; Ai, Songtao; Chen, Xiaojun; Wang, Liao; Dai, Kerong

    2017-01-01

    Determining three-dimensional (3D) acetabular orientation is important for several orthopaedic scenarios, but the complex geometries of both pelvis and acetabulum make measurements of orientation unreliable. Acetabular orientation may also differ between the sexes or racial groups. We aimed to (1) establish and evaluate a novel method for measuring 3D acetabular orientation, (2) apply this new method to a large population of Chinese subjects, and (3) report relevant characteristics of native acetabular orientation in this population. We obtained computed tomography scans taken for non-orthopaedic indications in 100 Chinese subjects (50 male, 50 female). A novel algorithm tailored to segmentation of the hip joint was used to construct 3D pelvic models from these scans. We developed a surface-based method to establish a reliable 3D pelvic coordinate system and software to semi-automatically measure 3D acetabular orientation. Differences in various acetabular orientations were compared within and between subjects, between male and female subjects, and between our subjects and subjects previously reported by another group. The reported method was reliable (intraclass correlation coefficient >0.999). Acetabular orientations were symmetrical within subjects, but ranged widely between subjects. The sexes differed significantly in acetabular anteversion (average difference, 3.0°; p < 0.001) and inclination (1.5°; p < 0.03). Acetabular anteversion and inclination were substantially smaller among our Chinese subjects than previously reported for American subjects. Thus, our method was reliable and sensitive, and we detected sex differences in 3D acetabular orientation. Awareness of differences between the sexes and races is the first step towards better reconstruction of the hip joint for all individuals and could also be applied to other orthopaedic scenarios. PMID:28207829

  17. Fix and replace; an emerging paradigm for treating acetabular fractures

    PubMed Central

    Murphy, Colin G.; Carrothers, Andrew D.

    2016-01-01

    Summary Although technically challenging even for the experienced surgeon, simultaneous open reduction and internal fixation (ORIF) of acetabular fracture and total hip replacement (THR) have some potential advantages over the more traditional treatment options in specific patient subgroups; theoretically allowing immediate weight bearing and faster rehabilitation, reducing the cost of inpatient stay, and reducing the risks of early and late local complications associated with standard treatment for this type of injury. We review the evolution of the indications and techniques, outline the surgical challenges, and discuss implant options and outcomes for this treatment paradigm. PMID:28228787

  18. Positioning.

    ERIC Educational Resources Information Center

    Conone, Ruth M.

    The key to positioning is the creation of a clear benefit image in the consumer's mind. One positioning strategy is creating in the prospect's mind a position that takes into consideration the company's or agency's strengths and weaknesses as well as those of its competitors. Another strategy is to gain entry into a position ladder owned by…

  19. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture

    PubMed Central

    2016-01-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum. PMID:27550496

  20. Atypical periprosthetic acetabular fracture in long-term alendronate therapy

    PubMed Central

    Marongiu, Giuseppe; Capone, Antonio

    2016-01-01

    Summary Bisphosphonates have been commonly used in the treatment of osteoporosis, demonstrating its efficacy in fracture risk reduction. However, even if are generally safe and well tolerated, concerns have emerged about atypical fractures related to its prolonged use. Although atypical femoral fracture are more common, case reports demonstrated that even other skeletal areas can be involved by unusual pattern of fracture. We report a atypical acetabular periprosthetic fracture in a 83-year-old female patient after prolonged alendronate treatment for osteoporosis and isolated acetabular revision surgery. The patient underwent to clinical, bioumoral and radiological evaluation and all the history cases were fully reported. We believe this periprosthetic fracture, according to the available data, may have similar underlying pathology to atypical femoral fractures. Awareness of symptoms, in addition to a regular radiographic survey may facilitate early diagnosis and possible prevention of spontaneous periprosthetic fractures, in patients receiving bisphosphonate therapy beyond 5 years. The treatment of this atypical periprosthetic fracture should include both surgical than pharmacological therapy to obtained bone healing. PMID:28228784

  1. Enhanced modified faraday cup for determination of power density distribution of electron beams

    DOEpatents

    Elmer, John W.; Teruya, Alan T.

    2001-01-01

    An improved tomographic technique for determining the power distribution of an electron or ion beam using electron beam profile data acquired by an enhanced modified Faraday cup to create an image of the current density in high and low power ion or electron beams. A refractory metal disk with a number of radially extending slits, one slit being about twice the width of the other slits, is placed above a Faraday cup. The electron or ion beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. The enlarged slit enables orientation of the beam profile with respect to the coordinates of the welding chamber. A second disk having slits therein is positioned below the first slit disk and inside of the Faraday cup and provides a shield to eliminate the majority of secondary electrons and ions from leaving the Faraday cup. Also, a ring is located below the second slit disk to help minimize the amount of secondary electrons and ions from being produced. In addition, a beam trap is located in the Faraday cup to provide even more containment of the electron or ion beam when full beam current is being examined through the center hole of the modified Faraday cup.

  2. Total arthroplasty in displaced dysplastic hips with acetabular reconstruction and femoral shortening - technical note.

    PubMed

    Silva, Paulo; de Oliveira, Leandro Alves; Coelho, Danilo Lopes; do Amaral, Rogério Andrade; Rebello, Percival Rosa; de Moraes, Frederico Barra

    2014-01-01

    To describe a new procedure of total hip replacement in patient with severe developmental dysplasia of the left hip, using technique of acetabular reconstruction with autogenous bone grafts and subtrochanteric shortening femoral osteotomy. Total hip replacement done in January of 2003. The Eftekhar's classification was used and included type D, neglected dislocations. Bone graft incorporated in acetabular shelf and femoral osteotomy. Our contribution is the use of an Allis plate to better fix acetabular grafts, avoiding loosening, and cerclage around bone graft in femoral osteotomy site, which diminish pseudoarthrosis risk. This technique shows efficiency, allowing immediately resolution for this case with pain and range of motion of hip improvement. It also allows the acetabular dysplasia reconstruction, equalization of the limb length (without elevated risk of neurovascular lesion) and repairs the normal hip biomechanics due to the correction of the hip's center of rotation.

  3. Long Term Results of Liner Polyethylene Cementation Technique in Revision for Peri-acetabular Osteolysis.

    PubMed

    Rivkin, Gurion; Kandel, Leonid; Qutteineh, Bilal; Liebergall, Meir; Mattan, Yoav

    2015-06-01

    Patients with peri-acetabular osteolysis around a well fixed cementless acetabular component may be treated with liner exchange. When the locking mechanism is unreliable or unavailable, cementing the liner into the fixed acetabular component is a feasible option. The purpose of this study was to evaluate the clinical and radiographic long term results of this technique. Forty hip revisions with liner cementation in 37 patients were performed. The minimum follow up was 10 years. Modified Harris Hip Score and recent x rays were reviewed. Four hips were re-revised. Two patients were diagnosed with exacerbation of osteolysis but refused revision. Dislocation rate was relatively high (16%). Liner cementation technique in revision hip surgery is useful in patients with a well fixed metal backed acetabular component.

  4. Fix and replace: An emerging paradigm for treating acetabular fractures in older patients

    PubMed Central

    Tissingh, Elizabeth K; Johnson, Abigail; Queally, Joseph M; Carrothers, Andrew D

    2017-01-01

    Acetabular fractures in older patients are challenging to manage. The “fix and replace” construct may present a new paradigm for the management of these injuries. We present the current challenge of acetabular fractures in older patients. We present this in the context of the current literature. This invited editorial presents early results from our centre and the ongoing challenges are discussed. PMID:28361014

  5. Retained Sponge: A Rare Complication in Acetabular Osteosinthesis

    PubMed Central

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Moran-Blanco, Luz María; Vaquero-Martín, Javier

    2015-01-01

    Retained sponges after a surgical treatment of polytrauma may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a 35-year-old man transferred from another hospital, that sustained a open acetabular fracture. The fracture was reduced through a limited ilio-inguinal approach. After 4 days, he presented massive wound dehiscence of the surgical approach. An abdominal CT scan showed, lying adjacent to the outer aspect of the left iliac crest, a mass of 10 cm, identified as probable foreign body. The possibility of this rare complication should be in the differential diagnosis of any postoperative patient who presents with pain, infection, or palpable mass. PMID:26312116

  6. Acetabular cartilage defects cause altered hip and knee joint coordination variability during gait

    PubMed Central

    Samaan, Michael A.; Teng, Hsiang-Ling; Kumar, Deepak; Lee, Sonia; Link, Thomas; Majumdar, Sharmila; Souza, Richard B.

    2015-01-01

    Background Patients with acetabular cartilage defects reported increased pain and disability compared to those without acetabular cartilage defects. The specific effects of acetabular cartilage defects on lower extremity coordination patterns are unclear. The purpose of this study was to determine hip and knee joint coordination variability during gait in those with and without acetabular cartilage defects. Methods A combined approach, consisting of a semi-quantitative MRI-based quantification method and vector coding, was used to assess hip and knee joint coordination variability during gait in those with and without acetabular cartilage lesions. Findings The coordination variability of the hip flexion-extension/knee rotation, hip abduction-adduction/knee rotation and hip rotation/knee rotation joint couplings were reduced in the acetabular lesion group compared to the control group during loading response of the gait cycle. The lesion group demonstrated increased variability in the hip flexion-extension/knee rotation and hip abduction-adduction/knee rotation joint couplings, compared to the control group, during the terminal stance/pre-swing phase of gait. Interpretation Reduced variability during loading response in the lesion group may suggest reduced movement strategies and a possible compensation mechanism for lower extremity instability during this phase of the gait cycle. During terminal stance/pre-swing, a larger variability in the lesion group may suggest increased movement strategies and represent a compensation or pain avoidance mechanism caused by the load applied to the hip joint. PMID:26298706

  7. Value of 3-D CT in classifying acetabular fractures during orthopedic residency training.

    PubMed

    Garrett, Jeffrey; Halvorson, Jason; Carroll, Eben; Webb, Lawrence X

    2012-05-01

    The complex anatomy of the pelvis and acetabulum have historically made classification and interpretation of acetabular fractures difficult for orthopedic trainees. The addition of 3-dimensional (3-D) computed tomography (CT) scan has gained popularity in preoperative planning, identification, and education of acetabular fractures given their complexity. Therefore, the authors examined the value of 3-D CT compared with conventional radiography in classifying acetabular fractures at different levels of orthopedic training. Their hypothesis was that 3-D CT would improve correct identification of acetabular fractures compared with conventional radiography.The classic Letournel fracture pattern classification system was presented in quiz format to 57 orthopedic residents and 20 fellowship-trained orthopedic traumatologists. A case consisted of (1) plain radiographs and 2-dimensional axial CT scans or (2) 3-D CT scans. All levels of training showed significant improvement in classifying acetabular fractures with 3-D vs 2-D CT, with the greatest benefit from 3-D CT found in junior residents (postgraduate years 1-3).Three-dimensional CT scans can be an effective educational tool for understanding the complex spatial anatomy of the pelvis, learning acetabular fracture patterns, and correctly applying a widely accepted fracture classification system.

  8. A plasma membrane template for macropinocytic cups

    PubMed Central

    Veltman, Douwe M; Williams, Thomas D; Bloomfield, Gareth; Chen, Bi-Chang; Betzig, Eric; Insall, Robert H; Kay, Robert R

    2016-01-01

    Macropinocytosis is a fundamental mechanism that allows cells to take up extracellular liquid into large vesicles. It critically depends on the formation of a ring of protrusive actin beneath the plasma membrane, which develops into the macropinocytic cup. We show that macropinocytic cups in Dictyostelium are organised around coincident intense patches of PIP3, active Ras and active Rac. These signalling patches are invariably associated with a ring of active SCAR/WAVE at their periphery, as are all examined structures based on PIP3 patches, including phagocytic cups and basal waves. Patch formation does not depend on the enclosing F-actin ring, and patches become enlarged when the RasGAP NF1 is mutated, showing that Ras plays an instructive role. New macropinocytic cups predominantly form by splitting from existing ones. We propose that cup-shaped plasma membrane structures form from self-organizing patches of active Ras/PIP3, which recruit a ring of actin nucleators to their periphery. DOI: http://dx.doi.org/10.7554/eLife.20085.001 PMID:27960076

  9. The capsular ligaments provide more hip rotational restraint than the acetabular labrum and the ligamentum teres

    PubMed Central

    van Arkel, R. J.; Amis, A. A.; Cobb, J. P.; Jeffers, J. R. T.

    2015-01-01

    In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty. Cite this article: Bone Joint J 2015; 97-B:484–91. PMID:25820886

  10. Quantitative Computerized Assessment of the Degree of Acetabular Bone Deficiency: Total radial Acetabular Bone Loss (TrABL)

    PubMed Central

    Gelaude, Frederik; Clijmans, Tim; Delport, Hendrik

    2011-01-01

    A novel quantitative, computerized, and, therefore, highly objective method is presented to assess the degree of total radical acetabular bone loss. The method, which is abbreviated to “TrABL”, makes use of advanced 3D CT-based image processing and effective 3D anatomical reconstruction methodology. The output data consist of a ratio and a graph, which can both be used for direct comparison between specimens. A first dataset of twelve highly deficient hemipelves, mainly Paprosky types IIIB, is used as illustration. Although generalization of the findings will require further investigation on a larger population, it can be assumed that the presented method has the potential to facilitate the preoperative use of existing classifications and related decision schemes for treatment selection in complex revision cases. PMID:22013539

  11. An Updated Review of the Efficacy of Cupping Therapy

    PubMed Central

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Background Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Method Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. Results 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Conclusions Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted. PMID:22389674

  12. Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients.

    PubMed

    Kadar, Thomas; Hallan, Geir; Aamodt, Arild; Indrekvam, Kari; Badawy, Mona; Skredderstuen, Arne; Havelin, Leif Ivar; Stokke, Terje; Haugan, Kristin; Espehaug, Birgitte; Furnes, Ove

    2011-08-01

    This randomized study was performed to compare wear and migration of five different cemented total hip joint articulations in 150 patients. The patients received either a Charnley femoral stem with a 22.2 mm head or a Spectron EF femoral stem with a 28 mm head. The Charnley articulated with a γ-sterilized Charnley Ogee acetabular cup. The Spectron EF was used with either EtO-sterilized non-cross-linked polyethylene (Reflection All-Poly) or highly cross-linked (Reflection All-Poly XLPE) cups, combined with either cobalt chrome (CoCr) or Oxinium femoral heads. The patients were followed with repeated RSA measurements for 2 years. After 2 years, the EtO-sterilized non-cross-linked Reflection All-Poly cups had more than four times higher proximal penetration than its highly cross-linked counterpart. Use of Oxinium femoral heads did not affect penetration at 2 years compared to heads made of CoCr. Further follow-up is needed to evaluate the benefits, if any, of Oxinium femoral heads in the clinical setting. The Charnley Ogee was not outperformed by the more recently introduced implants in our study. We conclude that this prostheses still represents a standard against which new implants can be measured.

  13. Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP)

    PubMed Central

    Sköldenberg, Olof; Rysinska, Agata; Chammout, Ghazi; Salemyr, Mats; Muren, Olle; Bodén, Henrik; Eisler, Thomas

    2016-01-01

    Introduction In vitro, Vitamin-E-diffused, highly cross-linked polyethylene (PE) has been shown to have superior wear resistance and improved mechanical properties when compared to those of standard highly cross-linked PE liners used in total hip arthroplasty (THA). The aim of the study is to evaluate the safety of a new cemented acetabular cup with Vitamin-E-doped PE regarding migration, head penetration and clinical results. Methods and analysis In this single-centre, double-blinded, randomised controlled trial, we will include 50 patients with primary hip osteoarthritis scheduled for THA and randomise them in a 1:1 ratio to a cemented cup with either argon gas-sterilised PE (control group) or Vitamin-E-diffused PE (vitamin-e group). All patients and the assessor of the primary outcome will be blinded and the same uncemented stem will be used for all participants. The primary end point will be proximal migration of the cup at 2 years after surgery measured with radiostereometry. Secondary end points include proximal migration at other follow-ups, total migration, femoral head penetration, clinical outcome scores and hip-related complications. Patients will be followed up at 3 months and at 1, 2, 5 and 10 years postoperatively. Results Results will be analysed using 95% CIs for the effect size. A regression model will also be used to adjust for stratification factors. Ethics and dissemination The ethical committee at Karolinska Institutet has approved the study. The first results from the study will be disseminated to the medical community via presentations and publications in relevant medical journals when the last patient included has been followed up for 2 years. Trial registration number NCT02254980. PMID:27388352

  14. Coffee to Go: Woman "Thinks" First Cup in 15 Years

    MedlinePlus

    ... turn Javascript on. Feature: NIBIB Robotics Coffee to Go: Woman "Thinks" First Cup in 15 Years Past ... Athlete Stands Again…On His Own! / Coffee to Go: Woman "Thinks" First Cup in 15 Years Spring ...

  15. Fast-response cup anemometer features cosine response

    NASA Technical Reports Server (NTRS)

    Frenzen, P.

    1968-01-01

    Six-cup, low-inertia anemometer combines high resolution and fast response with a unique ability to sense only the horizontal component of the winds fluctuating rapidly in three dimensions. Cup assemblies are fabricated of expanded polystyrene plastic.

  16. Improved analytical method to study the cup anemometer performance

    NASA Astrophysics Data System (ADS)

    Pindado, Santiago; Ramos-Cenzano, Alvaro; Cubas, Javier

    2015-10-01

    The cup anemometer rotor aerodynamics is analytically studied based on the aerodynamics of a single cup. The effect of the rotation on the aerodynamic force is included in the analytical model, together with the displacement of the aerodynamic center during one turn of the cup. The model can be fitted to the testing results, indicating the presence of both the aforementioned effects.

  17. Pelvic position and movement during hip replacement.

    PubMed

    Grammatopoulos, G; Pandit, H G; da Assunção, R; Taylor, A; McLardy-Smith, P; De Smet, K A; Murray, D W; Gill, H S

    2014-07-01

    The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient's pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ± 32), obliquity -4° (2sd ± 12), rotation -8° (2sd ± 14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior > lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ± 16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required.

  18. Fast Faraday Cup With High Bandwidth

    DOEpatents

    Deibele, Craig E [Knoxville, TN

    2006-03-14

    A circuit card stripline Fast Faraday cup quantitatively measures the picosecond time structure of a charged particle beam. The stripline configuration maintains signal integrity, and stitching of the stripline increases the bandwidth. A calibration procedure ensures the measurement of the absolute charge and time structure of the charged particle beam.

  19. Recycling disposable cups into paper plastic composites.

    PubMed

    Mitchell, Jonathan; Vandeperre, Luc; Dvorak, Rob; Kosior, Ed; Tarverdi, Karnik; Cheeseman, Christopher

    2014-11-01

    The majority of disposable cups are made from paper plastic laminates (PPL) which consist of high quality cellulose fibre with a thin internal polyethylene coating. There are limited recycling options for PPLs and this has contributed to disposable cups becoming a high profile, problematic waste. In this work disposable cups have been shredded to form PPL flakes and these have been used to reinforce polypropylene to form novel paper plastic composites (PPCs). The PPL flakes and polypropylene were mixed, extruded, pelletised and injection moulded at low temperatures to prevent degradation of the cellulose fibres. The level of PPL flake addition and the use of a maleated polyolefin coupling agent to enhance interfacial adhesion have been investigated. Samples have been characterised using tensile testing, dynamic mechanical analysis (DMA) and thermogravimetric analysis. Use of a coupling agent allows composites containing 40 wt.% of PPL flakes to increase tensile strength of PP by 50% to 30 MPa. The Young modulus also increases from 1 to 2.5 GPa and the work to fracture increases by a factor of 5. The work demonstrates that PPL disposable cups have potential to be beneficially reused as reinforcement in novel polypropylene composites.

  20. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... agent and the user applies it to the teeth to remove debris. (b) Classification. Class I...

  1. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... agent and the user applies it to the teeth to remove debris. (b) Classification. Class I...

  2. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... agent and the user applies it to the teeth to remove debris. (b) Classification. Class I...

  3. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... agent and the user applies it to the teeth to remove debris. (b) Classification. Class I...

  4. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... agent and the user applies it to the teeth to remove debris. (b) Classification. Class I...

  5. Nuclear Physics in a Coffee Cup

    ERIC Educational Resources Information Center

    Higbie, J.

    1974-01-01

    Discusses physical phenomena which can be demonstrated by using a coffee cup, involving the short-range field, alpha-particle scattering, standing waves, and Bohr's closed electron orbits. Indicates that observation of the physics of the classroom in everyday objects can attract student interest in physics learning. (CC)

  6. Femoral Version, Neck-Shaft Angle, and Acetabular Anteversion in Chinese Han Population

    PubMed Central

    Jiang, Nan; Peng, Lin; Al-Qwbani, Mohammed; Xie, Guo-Ping; Yang, Qin-Meng; Chai, Yu; Zhang, Qing; Yu, Bin

    2015-01-01

    Abstract Anatomic data regarding femoral version, neck-shaft angle, and acetabular anteversion are still limited in Chinese Han adult population. The aim of this study was to investigate the effects of age, sex, and body laterality on the 3 important anatomic indicators in Chinese Han healthy adults. Measurements were performed independently by 3 experienced observers using the picture archiving and communication system (PACS) in healthy adults who had received imaging tests of the femur and acetabulum between January 2009 and October 2014. Relevant data were measured and analyzed. A total of 466 adults (353 males and 113 females) were included. The mean femoral version, neck-shaft angle, and acetabular anteversion for all were 10.62, 133.02, and18.79, respectively. Age-based analysis showed that adults younger than 60 years had a significantly higher neck-shaft angle (P < 0.001) but a significantly lower acetabular anteversion (P < 0.001) than those older than 60 years. Sex-based analysis revealed that females had significantly higher values of femoral version (P < 0.001) and acetabular anteversion (P < 0.001) than males. Laterality-based analysis found the left side had a significantly lower acetabular anteversion (P < 0.001) than the right side. Outcomes of multiple linear regression analysis indicated that femoral version may be associated with sex (P < 0.001) but not age (P = 0.076) or laterality (P = 0.430), neck-shaft angle may be associated with age (P < 0.001) but not sex (P = 0.378) or laterality (P = 0.233), and acetabular anteversion may be associated with age (P < 0.001) and sex (P < 0.001) but not laterality (P = 0.060). In this representative Chinese cohort, neck-shaft angle may decrease, whereas acetabular anteversion may increase with age, females may have higher values of femoral version and acetabular anteversion than males, and the right body side may have a higher value of acetabular

  7. Predictors of poor outcome after both column acetabular fractures: a 30-year retrospective cohort study

    PubMed Central

    2013-01-01

    Background and Purpose Acetabular fractures are often combined with associated injuries to the hip joint. Some of these associated injuries seem to be responsible for poor long-term results and these injuries seem to affect the outcome independent of the quality of the acetabular reduction. The aim of our study was to analyze the outcome of both column acetabular fractures and the influence of osseous cofactors such as initial fracture displacement, hip dislocation, femoral head lesions and injuries of the acetabular joint surface. Methods A retrospective cohort study in patients with both column acetabular fractures treated over a 30 year period was performed. Patients with a follow-up of more than two years were invited for a clinical and radiological examination. Displacement was analyzed on initial and postoperative radiographs. Contusion and impaction of the femoral head was grouped. Injuries of the acetabular joint surface consisting of impaction, contusion and comminution were recorded. The Merle d’Aubigné Score was documented and radiographs were analysed for arthritis (Helfet classification), femoral head avascular necrosis (Ficat/Arlet classification) and heterotopic ossifications (Brooker classification). Results 115 patients were included in the follow up examination. Anatomic reduction (malreduction ≤ 1mm) was associated with a significantly better clinical outcome than nonanatomical reduction (p = 0.001). Initial displacement of more than 10mm (p = 0.031) and initial intraarticular fragments (p = 0.041) were associated with worse outcome. Other associated injuries, such as the presence of a femoral head dislocation, femoral head injuries and injuries to the acetabular joint surface showed no significant difference in outcome individually, but in fractures with more than two associated local injuries the risk for joint degeneration was significant higher (p < 0.001) than in cases with less than two of them. In the subgroup of

  8. Biorobotic adhesion in water using suction cups.

    PubMed

    Bandyopadhyay, Promode R; Hrubes, J Dana; Leinhos, Henry A

    2008-03-01

    Echeneid fish, limpets and octopi use suction cups for underwater adhesion. When echeneid fish use suckers to 'hitch a ride' on sharks (which have riblet-patterned skins), the apparent absence of any pump or plumbing may be an advantage over biorobotic suction cups. An intriguing question is: How do they achieve seemingly persistent leak-free contact at low energy cost over rough surfaces? The design features of their suckers are explored in a biorobotic context of adhesion in water over rough surfaces. We have carried out experiments to compare the release force and tenacity of man-made suction cups with those reported for limpets and echeneid fish. Applied tensile and shear release forces were monotonically increased until release. The effects of cup size and type, host surface roughness, curvature and liquid surface tension have been examined. The flow of water in the sharkskin-like host surface roughness has been characterized. The average tenacity is 5.28 N cm(-2) (sigma = 0.53 N cm(-2), N = 37) in the sub-ambient pressure range of 14.6-49.0 kPa, in man-made cups for monotonically increasing applied release force. The tenacity is lower for harmonically oscillating release forces. The dynamic structural interactions between the suction cup and the oscillating applied forcing are discussed. Inspired by the matching of sharkskin riblet topology in echeneid fish suckers, it was found that biorobotic sealed contact over rough surfaces is also feasible when the suction cup makes a negative copy of the rough host surface. However, for protracted, persistent contact, the negative topology would have to be maintained by active means. Energy has to be spent to maintain the negative host roughness topology to minute detail, and protracted hitch-riding on sharks for feeding may not be free for echeneid fish. Further work is needed on the mechanism and efficiency of the densely populated tiny actuators in the fish suckers that maintain leak-proof contact with minimal

  9. Wear of a sequentially annealed polyethylene acetabular liner

    PubMed Central

    Gascoyne, Trevor C; Petrak, Martin J; Turgeon, Thomas R; Bohm, Eric R

    2014-01-01

    Background and purpose We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventional and highly crosslinked polyethylene acetabular liners in the same group of RCT patients, with a minimum of 5 years of postoperative follow-up. Patients and methods Linear penetration of the femoral head into an X3 (Stryker) crosslinked polyethylene (XLPE) liner was measured in 18 patients (19 hips) using radiostereometric analysis (RSA). Femoral head penetration was also measured in 6 patients (6 hips) with a conventional polyethylene liner (CPE), which served as a control group. Results The median proximal femoral head penetration in the XLPE group after 5.5 years was 0.025 mm with a steady-state penetration rate of 0.001 mm/year between year 1 and year 5. The CPE liner showed a median proximal head penetration of 0.274 mm after 7.2 years, at a rate of 0.037 mm/year. Interpretation The Trident X3 sequentially annealed XLPE liner shows excellent in vivo wear resistance compared to non-crosslinked CPE liners at medium-term implantation. The rate of linear head penetration in the XLPE liners after > 5 years of follow-up was 0.001 mm/year, which is in close agreement with the results of previous studies. PMID:25140986

  10. A new predictive indicator by arthrography for future acetabular growth following conservative treatment of developmental dysplasia of the hip.

    PubMed

    Satsuma, Shinichi; Kobayashi, Daisuke; Kinugasa, Maki; Takeoka, Yoshiki; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-05-01

    The aim of this study was to find a new predictive indicator for acetabular growth of developmental dysplasia of the hip. Seventy-three hips that were diagnosed with developmental dysplasia of the hip and treated by conservative reduction were included in our study. In 30 hips with center-edge angle ≤ 10° at age 4, the center-edge of the acetabular limbus angle (CEALA) in the arthrogram was measured. On the basis of the results, CEALA was significantly smaller in the secondary acetabular dysplasia group than in the normal group at maturity. In conclusion, CEALA is a more reliable and accurate predictive indicator for acetabular development than center-edge angle or acetabular index.

  11. Reusable and disposable cups: An energy-based evaluation

    NASA Astrophysics Data System (ADS)

    Hocking, Martin B.

    1994-11-01

    A group of five different types of reusable and disposable hot drink cups have been analyzed in detail with respect to their overall energy costs during fabrication and use. Electricity generating methods and efficiencies have been found to be key factors in the primary energy consumption for the washing of reusable cups and a less important factor in cup fabrication. In Canada or the United States, over 500 or more use cycles, reusable cups are found to have about the same or slightly more energy consumption, use for use, as moulded polystyrene foam cups used once and then discarded. For the same area paper cups used once and discarded are found to consume less fossil fuel energy per use than any of the other cup types examined. Details of this analysis, which could facilitate the comparative assessment of other scenarios, are presented.

  12. Biomechanical Analysis of the Fixation System for T-Shaped Acetabular Fracture

    PubMed Central

    Fan, Yanping; Lei, Jianyin; Zhu, Feng; Li, Zhiqiang; Chen, Weiyi; Liu, Ximing

    2015-01-01

    This study aims to evaluate the biomechanical mechanism of fixation systems in the most frequent T-shaped acetabular fracture using finite element method. The treatment of acetabular fractures was based on extensive clinical experience. Three commonly accepted rigid fixation methods (double column reconstruction plates (P × 2), anterior column plate combined with posterior column screws (P + PS), and anterior column plate combined with quadrilateral area screws (P + QS)) were chosen for evaluation. On the basis of the finite element model, the biomechanics of these fixation systems were assessed through effective stiffness levels, stress distributions, force transfers, and displacements along the fracture lines. All three fixation systems can be used to obtain effective functional outcomes. The third fixation system (P + QS) was the optimal method for T-shaped acetabular fracture. This fixation system may reduce many of the risks and limitations associated with other fixation systems. PMID:26495030

  13. Central acetabular fracture with dislocation treated by minimally invasive plate osteosynthesis.

    PubMed

    2015-06-01

    Central acetabular fractures with dislocation are usually the result of high-energy trauma, resulting in joint incongruity, and are frequently associated with other injuries. Open reduction and internal fixation has been the standard treatment for acetabular fractures, but it is associated with extensive surgical trauma, and complications such as haematoma formation, iatrogenic nerve injury, and heterotopic ossification. We present the case of a 63-year-old female who sustained a central acetabular fracture of the hip with dislocation as a result of an automobile collision. Closed reduction of the dislocation was performed, and the fracture was managed by minimally invasive plate osteosynthesis using a specially prepared plate. At 01 year postoperatively, radiographs showed the fracture to have been well-healed with good congruity of the joint. However, heterotopic ossification of the joint was noted. The technique allowed reduction of the fracture with minimal surgical trauma.

  14. Oxidation and other property changes of retrieved sequentially annealed UHMWPE acetabular and tibial bearings.

    PubMed

    Reinitz, Steven D; Currier, Barbara H; Van Citters, Douglas W; Levine, Rayna A; Collier, John P

    2015-04-01

    This investigation analyzed retrieved sequentially crosslinked and annealed (SXL) ultra-high molecular weight polyethylene bearings to determine whether the material is chemically stable in vivo. A series of retrieved tibial and acetabular components were analyzed for changes in ketone oxidation, crosslink density, and free radical concentration. Oxidation was observed to increase with in vivo duration, and the rate of oxidation in tibial inserts was significantly greater than in acetabular liners. SXL acetabular bearings oxidized at a rate comparable to gamma-sterilized liners, while SXL tibial inserts oxidized at a significantly faster rate than their gamma-sterilized counterparts. A significant decrease in crosslink density with increased mean ketone oxidation index was observed, suggesting that in vivo oxidation may be causing material degradation. Furthermore, a subsurface whitened damage region was also found in a subset of the bearings, indicating the possibility of a clinically relevant decrease in mechanical properties of these components.

  15. Cementation of a polyethylene liner into a metal acetabular shell: a biomechanical study.

    PubMed

    Hofmann, Aaron A; Prince, Edward J; Drake, F Thurston; Hunt, Kenneth J

    2009-08-01

    Cementation of a liner into a well-fixed acetabular shell is common in revision hip arthroplasty. We compare the biomechanical strengths of cemented liners with standard locked liners. Fifty polyethylene liners were inserted into acetabular shells using the standard locking mechanism or 1 of 2 cement types then loaded to failure by torsion or lever-out testing. Lever-out testing showed that all cemented liners failed at similar loads to standard locked liners. With torsion testing, cemented liners failed at significantly higher loads than standard locked liners; roughening the liner increased load to failure. Cementation of an acetabular liner into a metal shell is safe and strong and a good alternative to metal shell replacement. Saw roughening of the polyethylene liner strengthens the poly-cement interface.

  16. Acetabular Fractures in the Elderly: Midterm Outcomes of Column Stabilisation and Primary Arthroplasty

    PubMed Central

    Ortega-Briones, A.; Smith, S.

    2017-01-01

    Background. Interest in arthroplasty techniques for periarticular or intra-articular fractures in the elderly/osteoporotic patient continues to rise, including for geriatric acetabular fractures. In line with this, many acetabular fracture surgeons are now undertaking acute total hip arthroplasty in elderly/osteoporotic patients. Little is known however of the outcomes of this procedure, beyond the first year after surgery. Questions/Purposes. We determined the clinical outcomes of a series of elderly osteoporotic patients (mean age at surgery 77.4 years) treated for acetabular fractures with column fixation and simultaneous total hip arthroplasty, at a mean of 49 months after surgery. Methods. 24 patients (25 hips) were reviewed at a mean of 49 months after surgery. The surgical technique employed has previously been described. Radiographs were obtained, and clinical outcomes were assessed using Harris Hip Scores and the Merle d'Aubigné score. Results. 14 hips were available for assessment (9 deceased, 2 lost to follow-up). No patient suffered any complications beyond the perioperative period, no acetabular components were loose clinically or on latest radiographs, and the mean Harris Hip Score was 92. All but one patient scored good or excellent on the Merle d'Aubigné score. Conclusions. Column fixation and simultaneous total hip arthroplasty are a viable option for complex geriatric acetabular fractures, with encouraging midterm results. We conclude that THR is a viable long-term solution in this situation provided that the acetabular columns are stabilised prior to implantation, but more research is needed to aid in overall management decision making. PMID:28194414

  17. Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro.

    PubMed

    Puente Reyna, Ana Laura; Jäger, Marcus; Floerkemeier, Thilo; Frecher, Sven; Delank, Karl-Stefan; Schilling, Christoph; Grupp, Thomas M

    2016-01-01

    Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination with a rough titanium conical inner surface on the fixation area. A direct comparison between in vitro wear simulator tests (equivalent to 3 years of use) and retrieved liners (average 13.1 months in situ) was done in order to evaluate the backside wear characteristics and behavior of these systems. Similar wear scores between in vitro tested and retrieved liners were observed. The results showed that this locking mechanism did not significantly produce wear marks at the backside of the polyethylene liners due to micromotion. In all the analyzed liners, the most common wear modes observed were small scratches at the cranial fixation zone directly below the rough titanium inner surface of the shell. It was concluded that most of the wear marks were produced during the insertion and removal of the liner, rather than during its time in situ.

  18. Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro

    PubMed Central

    Jäger, Marcus; Floerkemeier, Thilo; Frecher, Sven; Delank, Karl-Stefan

    2016-01-01

    Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination with a rough titanium conical inner surface on the fixation area. A direct comparison between in vitro wear simulator tests (equivalent to 3 years of use) and retrieved liners (average 13.1 months in situ) was done in order to evaluate the backside wear characteristics and behavior of these systems. Similar wear scores between in vitro tested and retrieved liners were observed. The results showed that this locking mechanism did not significantly produce wear marks at the backside of the polyethylene liners due to micromotion. In all the analyzed liners, the most common wear modes observed were small scratches at the cranial fixation zone directly below the rough titanium inner surface of the shell. It was concluded that most of the wear marks were produced during the insertion and removal of the liner, rather than during its time in situ. PMID:27722174

  19. The Importance of Seed Characteristics in the Dispersal of Splash-Cup Plants

    NASA Astrophysics Data System (ADS)

    Eklof, Joel; Pepper, Rachel Pepper; Echternach, Juliana

    2016-11-01

    Splash-cup plants disperse their seeds by exploiting the kinetic energy of raindrops. When raindrops impact the splash-cup, a 3-5 mm vessel that holds seeds, the seeds are projected up to 1 m away from the parent plant. It has been established, using 3D printed models, that a 40°cone angle maximizes dispersal distance when seeds are not present in the cup. We therefore use 40°cups with the addition of different types of seeds to determine the effect that seeds of varying characteristics have on the dispersal and splash dynamics of splash-cup plants. Splash characteristics and dispersal distances of seeds with differing characteristics such as size, shape, texture, density, and hydrophobicity were compared to one another, as well as to the case of having no seeds present. We found that the presence of seeds dramatically decreased dispersal distance and changed splash characteristics (are measured by the angle and velocity of the resulting splash). In addition, different types of seeds yielded splashes with differing dispersal distance and splash characteristics. Splash characteristics and dispersal distances of glass beads of differing hydrophobicity were compared to determine the effect hydrophobicity has on dispersal and splash dynamics. These beads yielded some differences in dispersal distance, but no notable difference in splash dynamics. Models of the conical fruit bodies of the splash-cups were 3D printed and high-speed video was used to find splash characteristics, and dispersal distance was calculated by measuring the distance from the model to the final resting position of the seeds and droplets.

  20. A growing problem: acetabular fractures in the elderly and the combined hip procedure.

    PubMed

    Buller, Leonard T; Lawrie, Charles M; Vilella, Fernando E

    2015-04-01

    Acetabular fractures in the elderly are most frequently the result of low-energy trauma and present unique management challenges to orthopedic surgeons. Evaluation and treatment should be performed in a multidisciplinary fashion with early involvement of internal medicine subspecialists and geriatricians. Distinct fracture patterns and pre-existing osteoarthritis and osteoporosis necessitate careful preoperative planning. The role of total hip arthroplasty should also be considered when surgical treatment is indicated. The outcomes of acetabular fractures in the elderly have improved, but complications remain higher and results less satisfactory than in younger individuals. The lack of randomized controlled trials has limited the ability to establish an evidence-based treatment algorithm.

  1. Acetabular roof stress fracture: a rare cause of hip pain in children

    PubMed Central

    Jlalia, Zied; Bellil, Mehdi; Ghachem, Maher Ben

    2016-01-01

    Stress fracture of acetabular roof is an unusual cause of hip pain. It is considered as an underdiagnosed entity. People who are more susceptible to experience this fracture are athletes, soldiers and dancers. We present the case of an 11 year old girl with a roof acetabular stress fracture for which the diagnosis and follow-ups were possible by the means of MRI. The treatment was keeping the child at a complete rest. Failure to abide with this treatment can cause the stress fracture to evaluate into a complete fracture. PMID:28154643

  2. Analysis of Earing in Deep Drawn Cups

    SciTech Connect

    Aretz, Holger; Aegerter, Johannes; Engler, Olaf

    2010-06-15

    The cup-drawing of a strongly anisotropic sheet metal is simulated using a commercial finite element software along with a user material subroutine. In order to accurately describe the plastic anisotropy of the material the well-known recent yield function 'Yld2004-18p' is extended. Regarding the experimental characterization of the considered material the occurrence of dynamic strain aging lead to an oscillating signal of the width change of the tensile samples, which prevented a reliable determination of plastic strain ratios (r-values). Thus, an improved measurement concept was developed that leads to a very robust and reproducible determination of r-values. Furthermore, a novel plane-strain tensile test sample is presented which is used for the characterization of the plastic anisotropy in biaxial loading states. A quantitative comparison with measured earing profiles of deep drawn cups illustrates the predictive capabilities of the numerical simulation.

  3. Compilation of LLNL CUP-2 Data

    SciTech Connect

    Eppich, G.; Kips, R.; Lindvall, R.

    2016-07-31

    The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results

  4. Autologous Membrane Induced Chondrogenesis (AMIC) for the treatment of acetabular chondral defect

    PubMed Central

    Fontana, Andrea

    2016-01-01

    Summary Background Acetabular chondral defect are very frequently associated to FAI. Treatment options are still questionable. Methods Between 2008 and 2014, 201 patients over 583 have been arthroscopically treated with the AMIC procedure for grade III and/or IV acetabular chondral lesions. Patients age was between 18 and 50 years; acetabular chondral lesion size was between 2 and 4 cm2; radiological Tönnis degree of osteoarthritis was ≤ 2. Results The mean follow up of the entire group of 201 patients was 5 years (from 8 to 2). Significant improvement, as measured by the mHHS, was observed at 6 months in comparison to preoperative levels (80.3 ± 8.3) (p<0.001). Continuous improvement with respect to each previous evaluation time point was seen, reaching the highest improvement level at the three year follow-up (85.5 ± 7.2). The mean mHHS improvement recorded at the five year follow-up compared with preoperative scores was 39.1 ± 5.9. Conclusions AMIC is a valid procedure to repair medium-sized chondral defects on the acetabular side of the hip found during treatment of FAI and lead to long-term favourable outcomes. Level of evidence IV. PMID:28066742

  5. Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements.

    PubMed

    Alshuhri, Abdullah A; Holsgrove, Timothy P; Miles, Anthony W; Cunningham, James L

    2015-08-01

    Current techniques for diagnosing early loosening of a total hip replacement (THR) are ineffective, especially for the acetabular component. Accordingly, new, accurate, and quantifiable methods are required. The aim of this study was to investigate the viability of vibrational analysis for accurately detecting acetabular component loosening. A simplified acetabular model was constructed using a Sawbones(®) foam block. By placing a thin silicone layer between the acetabular component and the Sawbones block, 2- and 4-mm soft tissue membranes were simulated representing different loosening scenarios. A constant amplitude sinusoidal excitation with a sweep range of 100-1500 Hz was used. Output vibration from the model was measured using an accelerometer and an ultrasound probe. Loosening was determined from output signal features such as the number and relative strength of observed harmonic frequencies. Both measurement methods were sufficient to measure the output vibration. Vibrational analysis reliably detected loosening corresponding to both 2 and 4 mm tissue membranes at driving frequencies between 100 and 1000 Hz (p < 0.01) using the accelerometer. In contrast, ultrasound detected 2-mm loosening at a frequency range of 850-1050 Hz (p < 0.01) and 4-mm loosening at 500-950 Hz (p < 0.01).

  6. Double-crush syndrome after acetabular fractures. A sign of poor prognosis.

    PubMed

    Giannoudis, P V; Da Costa, A A; Raman, R; Mohamed, A K; Smith, R M

    2005-03-01

    Injury to the sciatic nerve is one of the more serious complications of acetabular fracture and traumatic dislocation of the hip, both in the short and long term. We have reviewed prospectively patients, treated in our unit, for acetabular fractures who had concomitant injury to the sciatic nerve, with the aim of predicting the functional outcome after these injuries. Of 136 patients who underwent stabilisation of acetabular fractures, there were 27 (19.9%) with neurological injury. At initial presentation, 13 patients had a complete foot-drop, ten had weakness of the foot and four had burning pain and altered sensation over the dorsum of the foot. Serial electromyography (EMG) studies were performed and the degree of functional recovery was monitored using the grading system of the Medical Research Council. In nine patients with a foot-drop, there was evidence of a proximal acetabular (sciatic) and a distal knee (neck of fibula) nerve lesion, the double-crush syndrome. At the final follow-up, clinical examination and EMG studies showed full recovery in five of the ten patients with initial muscle weakness, and complete resolution in all four patients with sensory symptoms (burning pain and hyperaesthesia). There was improvement of functional capacity (motor and sensory) in two patients who presented initially with complete foot-drop. In the remaining 11 with foot-drop at presentation, including all nine with the double-crush lesion, there was no improvement in function at a mean follow-up of 4.3 years.

  7. The Sphere Anemometer - A Fast Alternative to Cup Anemometry

    NASA Astrophysics Data System (ADS)

    Heißelmann, Hendrik; Hölling, Michael; Peinke, Joachim

    The main problem of cup anemometry is the different response time for increasing and decreasing wind velocities due to its moment of inertia. This results in an overestimation of wind speed under turbulent wind conditions, the so-called over-speeding. Additionally, routine calibrations are necessary due to the wear of bearings. Motivated by these problems the sphere anemometer, a new simple and robust sensor for wind velocity measurements without moving parts, was developed at the University of Oldenburg. In contrast to other known thrust-based sensors, the sphere anemometer uses the light pointer principle to detect the deflection of a bending tube caused by the drag force acting on a sphere mounted at its top. This technique allows the simultaneous determination of wind speed and direction via a two-dimensional position sensitive detector.

  8. Aerodynamic Analysis of Cup Anemometers Performance: The Stationary Harmonic Response

    PubMed Central

    Pindado, Santiago; Cubas, Javier; Sanz-Andrés, Ángel

    2013-01-01

    The effect of cup anemometer shape parameters, such as the cups' shape, their size, and their center rotation radius, was experimentally analyzed. This analysis was based on both the calibration constants of the transfer function and the most important harmonic term of the rotor's movement, which due to the cup anemometer design is the third one. This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer's rotor and the mentioned third harmonic term of its movement. PMID:24381512

  9. Aerodynamic analysis of cup anemometers performance: the stationary harmonic response.

    PubMed

    Pindado, Santiago; Cubas, Javier; Sanz-Andrés, Angel

    2013-01-01

    The effect of cup anemometer shape parameters, such as the cups' shape, their size, and their center rotation radius, was experimentally analyzed. This analysis was based on both the calibration constants of the transfer function and the most important harmonic term of the rotor's movement, which due to the cup anemometer design is the third one. This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer's rotor and the mentioned third harmonic term of its movement.

  10. Demonstrated Performance of the Solar Probe Cup

    NASA Astrophysics Data System (ADS)

    Case, A. W.; Kasper, J. C.; Korreck, K. E.; Stevens, M. L.; Daigneau, P.; Freeman, M.; Caldwell, D.; Gauron, T.; Wright, K. H.; Bergner, H.; Cirtain, J. W.; Larson, D.; Brodu, E.; Balat-Pichelin, M.

    2013-12-01

    The Solar Probe Cup (SPC) is a Faraday Cup being developed for the Solar Probe Plus (SPP) mission. SPP will be the first spacecraft to directly measure the solar environment near the Alfven point in the atmosphere of the Sun, approaching to within 10 solar radii of the center of the Sun. In order to make the observations of radially flowing solar wind needed to address questions of coronal and solar wind heating and acceleration, SPC must operate while looking directly at the Sun. As a result, SPC will face a harsh and unprecidented environment, with component temperatures exceeding 1000C at closest approach. SPC is similar in design and operation to the two Faraday Cup instruments on the Wind spacecraft, which have been making stable measurements of the solar wind near Earth for two decades, with two key differences. SPC must survive and operate at extreme temperatures due to the levels of solar flux near the Sun, and it must record the solar wind approximately one thousand times faster than the instruments on Wind to keep up with the rapid variations expected near the Sun. We present results of a demonstration model of SPC operated in laboratory reproductions of the near-Sun environment. In the last year, SPC has been exposed to simulated encounter solar fluxes and resulting temperature profiles using a vaccum chamber and modified IMAX film projectors. In addition, SPC has been exposed to realistic ion beams. We show that SPC can operate in these environments, and make the measurements required for the sucess of the Solar Probe mission. Based on the performance of our prototype, the expected cadence and sensitivity of SPC will be discussed, with a focus on its ability to distinguish between models of heating in the solar corona.

  11. NCI Holds on to Defelice Cup | Poster

    Cancer.gov

    NCI kept the Defelice Cup trophy this year after beating Leidos Biomedical Research, 15 to 9, at the 10th annual Ronald H. Defelice Golf Tournament held on Columbus Day. Sixteen players on each team battled it out at the yearly contractor vs. government tournament held at Rattlewood Golf Course in Mount Airy, Md. NCI leads the series 6–4. “The score was the highest NCI margin of victory in the 10-year series,” said Denny Dougherty, retired senior subcontracts advisor at what was formerly SAIC-Frederick. “The intensity of the annual competition has increased each year and has become...

  12. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    PubMed

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction.

  13. Total arthroplasty in displaced dysplastic hips with acetabular reconstruction and femoral shortening – technical note☆☆☆

    PubMed Central

    Silva, Paulo; de Oliveira, Leandro Alves; Coelho, Danilo Lopes; do Amaral, Rogério Andrade; Rebello, Percival Rosa; de Moraes, Frederico Barra

    2014-01-01

    To describe a new procedure of total hip replacement in patient with severe developmental dysplasia of the left hip, using technique of acetabular reconstruction with autogenous bone grafts and subtrochanteric shortening femoral osteotomy. Total hip replacement done in January of 2003. The Eftekhar's classification was used and included type D, neglected dislocations. Bone graft incorporated in acetabular shelf and femoral osteotomy. Our contribution is the use of an Allis plate to better fix acetabular grafts, avoiding loosening, and cerclage around bone graft in femoral osteotomy site, which diminish pseudoarthrosis risk. This technique shows efficiency, allowing immediately resolution for this case with pain and range of motion of hip improvement. It also allows the acetabular dysplasia reconstruction, equalization of the limb length (without elevated risk of neurovascular lesion) and repairs the normal hip biomechanics due to the correction of the hip's center of rotation. PMID:26229775

  14. Characterization of a nonequilibrium XeCl laser-plasma by a movable Faraday cup

    NASA Astrophysics Data System (ADS)

    Doria, D.; Lorusso, A.; Belloni, F.; Nassisi, V.

    2004-02-01

    In this work the experimental results of a nonequilibrium laser-plasma induced by an ultraviolet 308 nm excimer laser are reported. All measurements were performed fixing the laser energy at 70 mJ. It was concentrated on a 0.0099 cm2 spot by a convergent focal lens of 15 cm focal length. The utilized target was a 99.99% pure Cu disk. An 8 cm in diameter movable Faraday cup was developed in order to detect the plasma flow pulse at different positions along a drift tube. Analyzing the time-of-flight pulse under different cup bias voltage, we were able to distinguish the electron pulse, the suprathermal ions, and the thermal evolution of the plasma. In addition, by applying a breakdown voltage as polarizing cup voltage, we characterized the duration of the neutral component. To determine the system particle production efficiency, the total etched material per pulse, 0.235 μg, and the fractional ionization were measured. The expelled particle flux distribution was measured by an optical transmission analysis of a Cu deposited film on a glass substrate. The plasma flow was detected along its propagation axis, between 6 and 40 cm far from the target. The ablation process expelled particles with an initial velocity of 34 km/s, while the maximum ion concentration was 1 μs after the laser pulse. The plasma created propagates with a mean velocity of about 20 km/s. During the propagation, the longitudinal plasma dimension changed from 2.8 cm, near the target, to 31 cm at the maximum cup distance analyzed. At lowest distances, the cup signal wave forms presented a plateau due to the high dense plasma undergone to the space charge regime governed by the Child-Langmuir law.

  15. [Aseptic, simultaneous and bilateral mobilisation due to an acetabular shell fracture in a 43 year-old patient].

    PubMed

    Ceretti, M; Fanelli, M; Pappalardo, S

    2014-01-01

    The acetabular shell mobilization is the main long-term complication in total hip replacement. Metal-back fracture has also to be considered among the possible causes of shell mobilization. A case is presented of bilateral acetabular shell mobilization due to the trabecular covering de-soldering from the metal-back in a 43 year-old patient, 13-14 years after the first surgery.

  16. Polystyrene cups and containers: styrene migration.

    PubMed

    Tawfik, M S; Huyghebaert, A

    1998-07-01

    The level of styrene migration from polystyrene cups was monitored in different food systems including: water, milk (0.5, 1.55 and 3.6% fat), cold beverages (apple juice, orange juice, carbonated water, cola, beer and chocolate drink), hot beverages (tea, coffee, chocolate and soup (0.0, 0.5, 1, 2, and 3.6% fat), take away foods (yogurt, jelly, pudding and ice-cream), as well as aqueous food simulants (3% acetic acid, 15, 50, and 100% ethanol) and olive oil. Styrene migration was found to be strongly dependent upon the fat content and storage temperature. Drinking water gave migration values considerably lower than all of the fatty foods. Ethanol at 15% showed a migration level equivalent to milk or soup containing 3.6% fat. Maximum observed migration for cold or hot beverages and take-away foods was 0.025% of the total styrene in the cup. Food simulants were responsible for higher migration (0.37% in 100% ethanol). A total of 60 food samples (yogurt, rice with milk, fromage, biogardes, and cheese) packed in polystyrene containers were collected from retail markets in Belgium, Germany, and the Netherlands. The level of styrene detected in the foods was always fat dependent.

  17. Nutrient disorders of 'Evolution' mealy-cup sage

    Technology Transfer Automated Retrieval System (TEKTRAN)

    To produce popular floriculture crops like mealy-cup sage (Salvia farinacea (Benth.)), growers must be equipped with cultural information including the ability to recognize and characterize disorders. Diagnostic criteria of nutrient disorders of mealy-cup sage are absent from the literature. Theref...

  18. A critical comparison of ten disposable cup LCAs

    SciTech Connect

    Harst, Eugenie van der; Potting, José

    2013-11-15

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) also shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches.

  19. Endurance and speed capacity of the Korea republic football national team during the world cup of 2010.

    PubMed

    Duk, Oh Sang; Min, Kim Sung; Kawczyński, Adam; Chmura, Paweł; Mroczek, Dariusz; Chmura, Jan

    2011-12-01

    The aim of the study was to characterize selected indices of endurance and speed of the Korea Republic team with reference to the four best teams during the World Cup of 2010. Five hundred and ninety-nine football players from thirty-two teams participated in the study. All teams played in the 2010 World Cup in South Africa. For the assessment of the players' motor activity during matches common kinematic test results were recorded using the Castrol Performance Index. The following variables were analysed: total distance covered by the team, distance covered by individual players, maximum running speed and average match running speed for the team and individual players, as well as with division with regard to playing position: defenders, midfielders, strikers. In comparison to the four best teams at the football World Cup of 2010, the Korea Republic players achieved the highest running speed (p≤0.05), and similar levels of covered distance and average match running speed.

  20. Pelvic, acetabular and hip fractures: What the surgeon should expect from the radiologist.

    PubMed

    Molière, S; Dosch, J-C; Bierry, G

    2016-01-01

    Pelvic ring fractures when caused by trauma, either violent or in demineralized bone, generally consist of injuries in both the anterior (pubic symphysis and rami) and posterior (iliac wing, sacrum, sacroiliac joint) portions. Injury classifications are based on injury mechanism and pelvic stability, and are used to determine treatment. Acetabular fractures, associated or not to pelvic ring disruption, are classified on the basis of fracture line, into elementary fractures of the acetabular walls, columns and roof, and into complex fractures. Fractures of the proximal end of the femur occur often on demineralized bone following low-energy trauma. The fractures are categorized by anatomic location (neck, trochanter and subtrochanteric region) and degree of displacement. These variables determine the risk of osteonecrosis of the femoral head, which is the main complication of such fractures.

  1. Sex assessment from the acetabular rim by means of image analysis.

    PubMed

    Benazzi, S; Maestri, C; Parisini, S; Vecchi, F; Gruppioni, G

    2008-08-25

    Determining sex from skeletal remains is one of the most important steps in archaeological and forensic anthropology. The present study considers the diagnostic value of the acetabulum based on its planar image and related metric data. For this purpose, 83 adult os coxae of known age were examined. Digital photos of the acetabular area were taken, with each bone in a standardized orientation. Technical drawing software was used to trace the acetabular rim and to measure the related dimensions (area, perimeter, longitudinal and transverse maximum width). The measurements were subjected to SPSS discriminant and classification function analysis. There were significant differences (p

  2. Arthroscopic excision of acetabular osteoid osteoma in a 7-year-old patient.

    PubMed

    Aşık, Mehmet; Erşen, Ali; Polat, Gökhan; Bilgili, Fuat; Tunalı, Onur

    2015-11-01

    The purpose of this study was to present the case report of a 7-year-old patient who was treated with hip arthroscopy for an acetabular osteoid osteoma. A 7-year-old patient was referred to our clinic with hip pain. In the assessment of the patient, an acetabular osteoid osteoma was detected in his right hip; it was adjacent to his triradiate cartilage. An arthroscopic surgery was planned as an alternative to open safe hip dislocation. The osteoid osteoma was completely removed with hip arthroscopy. Postoperative CT scanning and histopathological analysis confirmed the diagnosis. Exposure of the acetabulum can be problematic in paediatric patients due to the potential risks of open safe dislocation. Hip arthroscopy can safely be used for benign hip lesions in paediatric patients. Level of evidence Case report, Level V.

  3. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products.

  4. Revision of complex acetabular defects using cages with the aid of rapid prototyping.

    PubMed

    Li, Huiwu; Wang, Liao; Mao, Yuanqing; Wang, You; Dai, Kerong; Zhu, Zhenan

    2013-12-01

    This study details a method using rapid prototyping (RP) technique to assist in acetabular revision with complex bone defects. Hemi-pelvic RP models were built among 25 patients with complex acetabular bone defects. Each patient was scheduled to undergo revision using either commercially available or customized cages based on individualized RP models. Average follow-up was 4.4 years (range, 1 to 9 years). The average Harris hip score was 36.1 (range, 20 to 58) preoperatively and reached an average of 82.6 (range, 60-96) at the last follow-up. No mechanical failure or loosening was observed. One patient experienced hip dislocation 4 days postoperatively. The resultant findings of this study merit consideration of RP as a helpful clinical complement for dealing with some complex bone defect of acetabulum.

  5. Possibility of a spin cup method

    NASA Astrophysics Data System (ADS)

    Tokimitsu, Terumasa

    1998-09-01

    In reticle manufacturing process, error budget of CD uniformity includes error components caused from material process, exposure system, mask process and measurement technology. We examined error source coming from material process. In the previous paper, the variation of resists thickness was not so dominant to affect CD variation. But it is clear that the variation of resist thickness deeply affects CD linearity. We found that the variation of resists thickness is related to repeatability of fine patterns making such as an OPC structure. Because feature size of OPC patterns are almost as same as the smallest pattern size to be realized by current exposure systems.In this report we will show a method which is called 'spin cup' to achieve the sophisticated design for mask making as a resist coating machine maker. We hope it will be a solution to make mask which has highly accurate resist thickness.

  6. Damage evolution in acetabular replacements under long-term physiological loading conditions.

    PubMed

    Wang, J-Y; Heaton-Adegbile, P; New, A; Hussell, J G; Tong, J

    2009-05-29

    Damage development in cemented acetabular replacements has been studied in bovine pelvic bones under long-term physiological loading conditions, including normal walking, stair climbing and a combined block loading with representative routine activities. The physiological loading conditions were achieved using a specially designed hip simulator for fixation endurance testing. Damage was detected and monitored using micro-CT scanning at regular intervals of the experiments, and verified by microscopic studies post testing. The results show that debonding at the bone-cement interface defined the failure of cement fixation in all cases, and debondings initiated near the dome of the acetabulum in the superior-posterior quadrant, consistent with the high-stress region identified from the finite element analysis of implanted acetabular models Zant, N.P., Heaton-Adegbile, P., Hussell, J.G., Tong, J., 2008b. In-vitro fatigue failure of cemented acetabular replacements-a hip simulator study. Journal of Biomechanical Engineering, Transactions of the ASME, 130, 021019-1-9]; [Tong, J., Zant, N.P., Wang, J-Y., Heaton-Adegbile, P., Hussell, J.G., 2008. Fatigue in cemented acetabulum. International Journal of Fatigue, 30(8), 1366-1375].

  7. The Retroacetabular Angle Determines the Safe Angle for Screw Placement in Posterior Acetabular Fracture Fixation

    PubMed Central

    Tadros, Ayman M. A.; Oxland, Thomas R.; O'Brien, Peter

    2013-01-01

    Introduction. A method for the determination of safe angles for screws placed in the posterior acetabular wall based on preoperative computed tomography (CT) is described. It defines a retroacetabular angle and determines its variation in the population. Methods. The retroacetabular angle is the angle between the retroacetabular surface and the tangent to the posterior acetabular articular surface. Screws placed through the marginal posterior wall at an angle equal to the retroacetabular angle are extraarticular. Medial screws can be placed at larger angles whose difference from the retroacetabular angle is defined as the allowance angles. CT scans of all patients with acetabular fractures treated in our institute between September 2002 to July 2007 were used to measure the retroacetabular angle and tangent. Results. Two hundred thirty one patients were included. The average (range) age was 42 (15–74) years. The average (range) retroacetabular angle was 39 (30–47) degrees. The average (range) retroacetabular tangent was 36 (30–45) mm. Conclusions. Placing the screws at an average (range) angle of 39 (33–47) degrees of anterior inclination with the retroacetabular surface makes them extraarticular. Angles for medial screws are larger. Safe angles can be calculated preoperatively with a computer program. PMID:24959359

  8. Postural correction reduces hip pain in adult with acetabular dysplasia: a case report

    PubMed Central

    Lewis, Cara L.; Khuu, Anne; Marinko, Lee

    2015-01-01

    Developmental dysplasia of the hip is often diagnosed in infancy, but less severe cases of acetabular dysplasia are being detected in young active adults. The purpose of this case report is to present a non-surgical intervention for a 31-year-old female with mild acetabular dysplasia and an anterior acetabular labral tear. The patient presented with right anterior hip and groin pain, and she stood with the trunk swayed posterior to the pelvis (swayback posture). The hip pain was reproduced with the anterior impingement test. During gait, the patient maintained the swayback posture and reported 6/10 hip pain. Following correction of the patient’s posture, the patient’s pain rating was reduced to a 2/10 while walking. The patient was instructed to maintain the improved posture. At the 1 year follow-up, she demonstrated significantly improved posture in standing and walking. She had returned to recreational running and was generally pain-free. The patient demonstrated improvement on self-reported questionnaires for pain, function and activity. These findings suggest that alteration of posture can have an immediate and lasting effect on hip pain in persons with structural abnormality and labral pathology. PMID:25731688

  9. ANALYSIS OF THE SEGMENTAL IMPACTION OF FEMORAL HEAD FOLLOWING AN ACETABULAR FRACTURE SURGICALLY MANAGED

    PubMed Central

    Guimarães, Rodrigo Pereira; Kaleka, Camila Cohen; Cohen, Carina; Daniachi, Daniel; Keiske Ono, Nelson; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Riccioli, Walter

    2015-01-01

    Objective: Correlate the postoperative radiographic evaluation with variables accompanying acetabular fractures in order to determine the predictive factors for segmental impaction of femoral head. Methods: Retrospective analysis of medial files of patients submitted to open reduction surgery with internal acetabular fixation. Within approximately 35 years, 596 patients were treated for acetabular fractures; 267 were followed up for at least two years. The others were excluded either because their follow up was shorter than the minimum time, or as a result of the lack of sufficient data reported on files, or because they had been submitted to non-surgical treatment. The patients were followed up by one of three surgeons of the group using the Merle d'Aubigné and Postel clinical scales as well as radiological studies. Results: Only tow studied variables-age and amount of postoperative reductionshowed statistically significant correlation with femoral head impaction. Conclusions: The quality of reduction-anatomical or with up to 2mm residual deviation-presents a good radiographic evolution, reducing the potential for segmental impaction of the femoral head, a statistically significant finding. PMID:27004191

  10. Articular cartilage friction increases in hip joints after the removal of acetabular labrum.

    PubMed

    Song, Yongnam; Ito, Hiroshi; Kourtis, Lampros; Safran, Marc R; Carter, Dennis R; Giori, Nicholas J

    2012-02-02

    The acetabular labrum is believed to have a sealing function. However, a torn labrum may not effectively prevent joint fluid from escaping a compressed joint, resulting in impaired lubrication. We aimed to understand the role of the acetabular labrum in maintaining a low friction environment in the hip joint. We did this by measuring the resistance to rotation (RTR) of the hip, which reflects the friction of the articular cartilage surface, following focal and complete labrectomy. Five cadaveric hips without evidence of osteoarthritis and impingement were tested. We measured resistance to rotation of the hip joint during 0.5, 1, 2, and 3 times body weight (BW) cyclic loading in the intact hip, and after focal and complete labrectomy. Resistance to rotation, which reflects articular cartilage friction in an intact hip was significantly increased following focal labrectomy at 1-3 BW loading, and following complete labrectomy at all load levels. The acetabular labrum appears to maintain a low friction environment, possibly by sealing the joint from fluid exudation. Even focal labrectomy may result in increased joint friction, a condition that may be detrimental to articular cartilage and lead to osteoarthritis.

  11. The translational regulator Cup controls NMJ presynaptic terminal morphology

    PubMed Central

    Menon, Kaushiki P.; Carrillo, Robert A.; Zinn, Kai

    2015-01-01

    During oogenesis and early embryonic development in Drosophila, translation of proteins from maternally deposited mRNAs is tightly controlled. We and others have previously shown that translational regulatory proteins that function during oogenesis also have essential roles in the nervous system. Here we examine the role of Cup in neuromuscular system development. Maternal Cup controls translation of localized mRNAs encoding the Oskar and Nanos proteins and binds to the general translation initiation factor eIF4E. In this paper, we show that zygotic Cup protein is localized to presynaptic terminals at larval neuromuscular junctions (NMJs). cup mutant NMJs have strong phenotypes characterized by the presence of small clustered boutons called satellite boutons. They also exhibit an increase in the frequency of spontaneous glutamate release events (mEPSPs). Reduction of eIF4E expression synergizes with partial loss of Cup expression to produce satellite bouton phenotypes. The presence of satellite boutons is often associated with increases in retrograde bone morphogenetic protein (BMP) signaling, and we show that synaptic BMP signaling is elevated in cup mutants. cup genetically interacts with four genes (EndoA, WASp, Dap160, and Synj) encoding proteins involved in endocytosis that are also neuronal modulators of the BMP pathway. Endophilin protein, encoded by the EndoA gene, is downregulated in a cup mutant. Our results are consistent with a model in which Cup and eIF4E work together to ensure efficient localization and translation of endocytosis proteins in motor neurons and control the strength of the retrograde BMP signal. PMID:26102195

  12. Cup anemometer calibration: effect of flow velocity distribution

    NASA Astrophysics Data System (ADS)

    Piccato, A.; Spazzini, P. G.; Malvano, R.

    2011-10-01

    The effects of different working conditions and specifically of different velocity profiles on the output of a commercial cup anemometer were analysed experimentally. A simple mathematical model is also presented and provides results in line with the experiments. Results show that a cup anemometer with certain geometrical features can be calibrated through a rotating drag rig by correcting for the bias on the instrument output. The increase in uncertainty caused by this systematic correction was evaluated and applied to the results. The correction was validated by checking the compatibility of calibrations of a cup anemometer at the rotating rig and in a wind tunnel.

  13. Response function of modulated grid Faraday cup plasma instruments

    NASA Technical Reports Server (NTRS)

    Barnett, A.; Olbert, S.

    1986-01-01

    Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager plasma science experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. Multisensor analysis of solar wind data indicates that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.

  14. Structural and Functional Characterization of Pseudomonas aeruginosa CupB Chaperones

    PubMed Central

    Cai, Xun; Wang, Rui; Filloux, Alain; Waksman, Gabriel; Meng, Guoyu

    2011-01-01

    Pseudomonas aeruginosa, an important human pathogen, is estimated to be responsible for ∼10% of nosocomial infections worldwide. The pathogenesis of P. aeruginosa starts from its colonization in the damaged tissue or medical devices (e.g. catheters, prothesis and implanted heart valve etc.) facilitated by several extracellular adhesive factors including fimbrial pili. Several clusters containing fimbrial genes have been previously identified on the P. aeruginosa chromosome and named cup [1]. The assembly of the CupB pili is thought to be coordinated by two chaperones, CupB2 and CupB4. However, due to the lack of structural and biochemical data, their chaperone activities remain speculative. In this study, we report the 2.5 Å crystal structure of P. aeruginosa CupB2. Based on the structure, we further tested the binding specificity of CupB2 and CupB4 towards CupB1 (the presumed major pilus subunit) and CupB6 (the putative adhesin) using limited trypsin digestion and strep-tactin pull-down assay. The structural and biochemical data suggest that CupB2 and CupB4 might play different, but not redundant, roles in CupB secretion. CupB2 is likely to be the chaperone of CupB1, and CupB4 could be the chaperone of CupB4:CupB5:CupB6, in which the interaction of CupB4 and CupB6 might be mediated via CupB5. PMID:21304995

  15. 78 FR 32990 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... the on-water activities associated with the ``Louis Vuitton Cup, Red Bull Youth America's Cup and the... Alcatraz Island. (77 FR 41902) The special local regulation and safety zone regulate the on-water activities associated with the ``Louis Vuitton Cup, Red Bull Youth America's Cup and the 34th America's...

  16. Characterization of Human Anterosuperior Acetabular Depression in Correlation With Labral Tears

    PubMed Central

    Kopydlowski, Nathan J.; Tannenbaum, Eric P.; Smith, Matthew V.; Sekiya, Jon K.

    2014-01-01

    Background: Labral tears often occur in the same quadrant of the acetabulum at a small depression previously referred to as the psoas valley. Understanding the anatomic variations of this depression could help us understand the etiology of labral tears. Purpose: To describe the location and dimensions of the depression located in the anterosuperior acetabular rim. The hypothesis was that the location of this depression would be consistent with the common location of acetabular labral tears described in the literature. Study Design: Controlled laboratory study. Methods: A total of 240 pelvic specimens were divided into 2 groups (n = 120 for each) according to age (younger age group: 21.36 ± 3.12 years [range, 14-24 years]; older age group: 42.30 ± 10.27 years, [range, 25-60 years]).Specimens were also categorized based on sex (mean age: 31.93 ± 12.31 years [male]; 32.08 ± 13.66 years [female]) and race (mean age: 31.45 ± 13.16 years [black]; 32.57 ± 12.82 years [white]). The depth and width of the acetabular depression were measured using a digital caliper, and the location was measured using a goniometer. Results: The psoas valley was observed in every specimen and was located in the anterosuperior quadrant of the acetabulum. Its depth was significantly greater (P < .001) in males (5.35 ± 1.60 mm) than in females (3.95 ± 1.31 mm). The width of the psoas valley was also greater (P < .001) in males (29.39 ± 3.98 mm) than in females (24.49 ± 4.80 mm). There were no differences in size or location of the depression between races or age groups. The psoas valley was located between 3.92 ± 0.42 o’clock anteriorly and 2.12 ± 0.77 o’clock posteriorly. Conclusion: The differences observed in the study data are believed to be a result of the different anatomic morphologies of the pelvis in males and females. This loss of bony support, caused by the depression, could be the underlying cause of weakening of the acetabular labrum as people age. Clinical Relevance

  17. Application of a stereometric structural analysis for an evaluation of surface and for a forecast of the wear of endoprothesis acetabular cups

    SciTech Connect

    Cybo, Jerzy; Maszybrocka, Joanna . E-mail: jmaszybr@us.edu.pl; Cwajna, Jan

    2006-06-15

    To improve the resistance to wear and permanent deformation of polyethylene operating in a polymer/metal friction couple, initial plastic deformation of the polyethylene and its electron irradiation was applied. This contributed to a change of the polymer structure, visible already while machining when the sample surfaces were being prepared for a tribological test. The study shows that the interactions that shape the structure of polyethylene, at the same time cause adequate changes to the stereometric structure of its surface. The parameters of surface microgeometry characterize the future tribological behavior of polyethylene during its operation in a friction couple. It has been shown that an analysis of stereometric parameters may constitute the first projection of polymer wear resistance.

  18. "The Gammage Cup" as Utopian Literature for Children.

    ERIC Educational Resources Information Center

    Russell, David L.

    1993-01-01

    Considers how Carol Kendall's fantasy novel, "The Gammage Cup," can be read as utopian literature for children. Provides a close reading and explication of Kendall's novel. Pronounces Kendall's novel a stimulating success providing hope for young readers. (HB)

  19. Space Coffee Cup: Capillary Flow Driven Fluids in Space

    NASA Video Gallery

    Interested in learning more about how fluids react in Space? In this video, Professor Mark Weislogel, and Dr. Marshall Porterfield will discuss the Space Coffee Cup and Capillary Flow Driven Fluids...

  20. Figuring out the Statistics of the ICC World Cup 2011

    ERIC Educational Resources Information Center

    Shiwalkar, Jyoti P.; Deshpande, M. N.

    2013-01-01

    This paper deals with the analysis of cricket match results from the ICC World Cup 2011. We believe that such data provide good material for interesting classroom exercises. (Contains 7 tables and 1 figure.)

  1. Sound of a cup with and without instant coffee

    NASA Astrophysics Data System (ADS)

    Morrison, Andrew; Rossing, Thomas D.

    2002-05-01

    An empty coffee cup, like an ancient Chinese two-tone bell, emits two distinctly different tones, depending upon where it is tapped. When it is filled with hot water, and some instant coffee is added, however, a whole new set of sounds is heard when the cup is tapped. The pitch rises an octave or more as the foam clears due to the dramatic change in the speed of sound in the bubble-filled liquid. A similar, but smaller, effect was noted in beer by Bragg [The World of Sound (1968)] and in hot chocolate by Crawford [Am. J. Phys. (1982)]. We describe the modes of vibration in a coffee cup and the sound emitted by a coffee cup as filled with instant coffee as the bubble density changes.

  2. Prevalence of disc cupping in non-glaucomatous eyes.

    PubMed

    Chiappe, José Pablo; Nahum, Pablo; Casiraghi, Javier F; Iribarren, Rafael

    2015-01-01

    This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter < 1.0, 1.0-1.5, or > 1.5 times (respectively) the diameter of the ophthalmoscope's selected light spot on the posterior pole. The cupping was classified as the ratio of the vertical cupping diameter and the vertical disc diameter on a relative decimal scale from 0.0 to 1.0.This study included 184 subjects with a mean age of 40.5 ± 9.5 years; 149 (81%) were males. Their mean ocular pressure was 12.4 ± 1.5 mmHg (range 10-17 mmHg). There was a high correlation between optic disc sizes and cupping in the right and left eyes (Pearson Correlation r = 0.866, p < 0.001); therefore, for simplicity only the data for right eyes are presented. According to our definition, the optic discs in these eyes comprised 27 (14.7%) small, 141 (76.6%) medium and 16 (8.7%) large. The small optic discs were rarely cupped, and the large optic discs were always cupped. Optic disc cupping greater than 0.7 was rarely found and should be suspect of glaucoma. Clinical doctors should be aware of this and refer those subjects with abnormal cupping to the specialist.

  3. Space Experiment Concepts: Cup-Burner Flame Extinguishment

    NASA Technical Reports Server (NTRS)

    Takahashi, Fumiaki

    2004-01-01

    Space Fire Suppression Processes & Technology. Space experiment concepts of cup-burner flame extinguishment have been conceived to address to the key issues (i.e., organizing questions) in space fire suppression. Cup-burner flame extinguishment experiment can reveal physical and chemical suppression processes and provide agent effectiveness data useful for technology development of space fire suppression systems in various reduced-gravity platforms.

  4. Collective efficacy at the Rugby World Cup 2015--The role of imagery and observation.

    PubMed

    Shearer, David A

    2015-01-01

    The Rugby World Cup in 2015 will present each competing team with unique psychological challenges not usually encountered in normal international fixtures. In the "pressure-pot" environment of the tournament, teams that have the strongest sense of collective efficacy will most likely perform to their best and respond positively to the outside stressors (e.g., media interest, public expectations). In this review, the importance of collective efficacy to team performance at the World Cup in terms of team resiliency and minimising process losses is discussed. In addition, the relationship between collective efficacy and other psychological factors such as team cohesion is highlighted. From a practical perspective, an introduction to interventions to develop collective efficacy is provided. In particular, the neuroscience evidence for the use of imagery and observation interventions to improve individual collective efficacy perceptions is highlighted. It is emphasised how these interventions are particularly suited to international teams who compete together sporadically. Finally, specific recommendations are made such that practitioners might be able to implement these strategies with their teams before the World Cup.

  5. A Zero-Gravity Cup for Drinking Beverages in Microgravity

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Weislogel, Mark; Concus, Paul; Finn, Robert

    2011-01-01

    To date, the method for astronauts to drink liquids in microgravity or weightless environments is to suck the liquid from a bag or pouch through a straw. A new beverage cup works in microgravity and allows astronauts to drink liquids from a cup in a manner consistent with that on Earth. The cup is capable of holding beverages with an angled channel running along the wall from the bottom to the lip. In microgravity, a beverage is placed into the cup using the galley dispenser. The angled channel acts as an open passage that contains only two sides where capillary forces move the liquid along the channel until it reaches the top lip where the forces reach an equilibrium and the flow stops. When one sips the liquid at the lip of the channel, the capillary force equilibrium is upset and more liquid flows to the lip from the reservoir at the bottom to re-establish the equilibrium. This sipping process can continue until the total liquid contents of the cup is consumed, leaving only a few residual drops about the same quantity as in a ceramic cup when it is drunk dry on Earth.

  6. Splash-cup plants accelerate raindrops to disperse seeds.

    PubMed

    Amador, Guillermo J; Yamada, Yasukuni; McCurley, Matthew; Hu, David L

    2013-02-01

    The conical flowers of splash-cup plants Chrysosplenium and Mazus catch raindrops opportunistically, exploiting the subsequent splash to disperse their seeds. In this combined experimental and theoretical study, we elucidate their mechanism for maximizing dispersal distance. We fabricate conical plant mimics using three-dimensional printing, and use high-speed video to visualize splash profiles and seed travel distance. Drop impacts that strike the cup off-centre achieve the largest dispersal distances of up to 1 m. Such distances are achieved because splash speeds are three to five times faster than incoming drop speeds, and so faster than the traditionally studied splashes occurring upon horizontal surfaces. This anomalous splash speed is because of the superposition of two components of momentum, one associated with a component of the drop's motion parallel to the splash-cup surface, and the other associated with film spreading induced by impact with the splash-cup. Our model incorporating these effects predicts the observed dispersal distance within 6-18% error. According to our experiments, the optimal cone angle for the splash-cup is 40°, a value consistent with the average of five species of splash-cup plants. This optimal angle arises from the competing effects of velocity amplification and projectile launching angle.

  7. The Effect of Chin-cup Therapy in Class III Malocclusion: A Systematic Review

    PubMed Central

    Mousoulea, Sophia; Tsolakis, Ioannis; Ferdianakis, Efstratios; Tsolakis, Apostolos I.

    2016-01-01

    Background: The treatment of Class III malocclusion has been challenging for orthodontists. Among a plethora of treatment modalities, the chin-cup is considered a traditional appliance for early orthopedic intervention. Objective: The present study aims to investigate the current scientific evidence regarding the effectiveness of chin-cup therapy in Class III malocclusion of prognathic growing patients. Method: A systematic review of the literature was conducted using PubMed/Medline and the Cochrane Central Register of Controlled Trials from January 1954 to October 2015. Articles were selected based on established inclusion/ exclusion criteria. Results: The search strategy resulted in 3285 articles.14 studies were selected for the final analysis. They were all CCTs, 13 of retrospective and 1 of prospective design. Methodological quality was evaluated by a risk of bias assessment, as suggested by the Cochrane Risk of Bias Assessment Tool for Non-Randomized Studies on Interventions. The reported evidence presented favorable short-term outcomes both in hard and soft tissues improving the Class III profile, as well as desirable dento-alveolar changes, positively affecting the Class III malocclusion. Conclusion: There is considerable agreement between studies that chin-cup therapy can be considered for the short-term treatment of growing patients with Class III malocclusion, as indicated by favorable changes both in the hard and soft tissues. The existence of considerable risk of bias in all selected studies and the unclear long-term effectiveness of chin-cup therapy highlight the need for further investigation to draw reliable conclusions. PMID:28077971

  8. Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty

    PubMed Central

    Gonzalez, Amanda Inez; Bartolone, Placido; Lubbeke, Anne; Dupuis Lozeron, Elise; Peter, Robin; Hoffmeyer, Pierre; Christofilopoulos, Panayiotis

    2017-01-01

    Background and purpose — Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods — We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25–98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0–128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0–136) months. Results — The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11–1.02) and the adjusted RR was 0.28 (95% CI: 0.09–0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3–1.4). Interpretation — Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months. PMID:27841712

  9. Inversion of the acetabular labrum triggers rapidly destructive osteoarthritis of the hip: representative case report and proposed etiology.

    PubMed

    Fukui, Kiyokazu; Kaneuji, Ayumi; Fukushima, Mana; Matsumoto, Tadami

    2014-12-01

    The pathophysiology of rapidly destructive osteoarthritis (OA) of the hip is unknown. This study documented cases of inversion of the acetabular labrum, which has clinicoradiologic features similar to those of initial-stage rapidly destructive hip OA. Our study was based on a prospective review of data for 9 patients with rapidly destructive hip OA. Intraoperative findings showed that the anterosuperior portion of the acetabular labrum had inverted into the articular space, along with many fragments of articular cartilage, in all patients. Subchondral insufficiency fractures of the femoral heads were seen just under the inverted labra in 8 of the 9 patients. Inversion of the acetabular labrum may be involved in rapid joint-space narrowing and subchondral insufficiency fracture in rapidly destructive hip OA.

  10. MRI findings following metal on metal hip arthroplasty and their relationship with metal ion levels and acetabular inclination angles.

    PubMed

    Fox, Ciara M; Bergin, Karen M; Kelly, Gabrielle E; McCoy, Gerry F; Ryan, Anthony G; Quinlan, John F

    2014-08-01

    Following the global recall of all ASR metal on metal hip products, our aim was to correlate MRI findings with acetabular inclination angles and metal ion levels in patients with these implants. Both cobalt and chromium levels were significantly higher in the presence of a periprosthetic fluid collection. There was no association between the presence of a periprosthetic mass, bone marrow oedema, trochanteric bursitis or greater levels of abductor muscle destruction for cobalt or chromium. There was no association between the level of periprosthetic tissue reaction and the acetabular inclination angle with any of the pathologies identified on MRI. The relationship between MRI pathology, metal ion levels and acetabular inclination angles in patients with ASR implants remains unclear adding to the complexity of managing patients.

  11. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    PubMed

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing.

  12. Fucntional and Radiological Outcome of Surgical Management of Acetabular Fractures in Tertiary Care Hospital

    PubMed Central

    Taufiq, Intikhab; Najjad, Muhammad Kazim Raheem; Khan, Naveed; Zia, Osama Bin

    2016-01-01

    Purpose Acetabular fractures are mainly caused by trauma and the incidence is rising in developing countries. Initially these fractures were managed conservatively, due to lack of specialized and dedicated acetabulum surgery centres. Our aim is to study the radiological and functional outcomes of surgical management of acetabular fractures in tertiary care hospital. Materials and Methods Total 50 patients were enrolled. The patients with acetabular fractures were enrolled between the years 2012 to 2014. Patients were evaluated clinically with Harris hip score (HHS) and radiologically with Matta outcome grading. The factors examined include age, gender, fracture pattern, time between injury and surgery, initial displacement and quality of reduction on the final outcome. Results There were 34 males and 16 females. Mean age was 44.20±11.65 years while mean duration of stay was 9.28±2.36 days. Duration of follow-up was 24 months. Most common mechanism of injury was motor vehicle accident (n=37, 74.0%). Open reduction and internal fixation of fractures were performed using reconstruction plates. Mean HHS at 24 months was 82.36±8.55. The clinical outcome was acceptable (excellent or good) in 35 (70.0%) cases and not acceptable (fair or poor) in 15 (30.0%) cases. The radiological outcome was anatomical in 39 (78.0%) cases, congruent in 5 (10.0%) cases, incongruent in 6 (12.0%) cases. Conclusion Study results indicated that mechanism of injury, time between injury and surgery, initial degree of displacement and quality of reduction had significant effect on functional as well as radiological outcome. PMID:28097111

  13. Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

    PubMed

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Howie, Donald W

    2016-06-30

    A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

  14. Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study.

    PubMed

    Ghosh, Rajesh

    2016-09-01

    The aim of the study is to determine failure of the cemented polyethylene acetabular component, which might occur due to excessive bone resorption, cement-bone interface debonding and fatigue failure of the cement mantle. Three-dimensional finite element models of intact and implanted pelvic bone were developed and bone remodeling algorithm was implemented for present analysis. Soderberg fatigue failure diagram was used for fatigue assessment of the cement mantle. Hoffman failure criterion was considered for prediction of cement-bone interface debonding. Results indicate fatigue failure of the cement mantle and implant-bone interface debonding might not occur due to bone remodeling.

  15. Femoro-acetabular impingement clinical research: is a composite outcome the answer?

    PubMed

    Ayeni, Olufemi R; Sansone, Mikael; de Sa, Darren; Simunovic, Nicole; Bedi, Asheesh; Kelly, Bryan T; Farrokhyar, Forough; Karlsson, Jon

    2016-01-01

    Femoro-acetabular impingement (FAI) is increasingly recognized as an important cause of hip pain in the young adult. However, the methods of evaluating the efficacy of surgical intervention are often not validated and/or inconsistently reported. Important clinical, gait, radiographic and biomarker outcomes are discussed. This article (1) presents the rationale for considering a composite outcome for FAI patients; (2) examines a variety of important end points currently used to evaluate FAI surgery; (3) discusses a strategy to generate a composite outcome by combining these end points; and (4) highlights the challenges and current areas of controversy that such an approach to evaluating symptomatic FAI patients may present.

  16. Dielectric elastomer actuators for octopus inspired suction cups.

    PubMed

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  17. Octopus-like suction cups: from natural to artificial solutions.

    PubMed

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  18. Metal-backed acetabular components with conventional polyethylene: a review of 9113 primary components with a follow-up of 20 years.

    PubMed

    Hallan, G; Dybvik, E; Furnes, O; Havelin, L I

    2010-02-01

    The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncemented metal-backed acetabular components. A total of 9113 primary uncemented acetabular components were implanted in 7937 patients between 1987 and 2007. These were included in a prospective, population-based observational study. All the implants were modular and metal-backed with ultra-high-molecular-weight polyethylene liners. The femoral heads were made of stainless steel, cobalt-chrome (CoCr) alloy or alumina ceramic. In all, seven different designs of acetabular component were evaluated by the Kaplan-Meier survivorship method and Cox regression analysis. Most acetabular components performed well up to seven years. When the endpoint was revision of the acetabular component because of aseptic loosening, the survival ranged between 87% and 100% at ten years. However, when the endpoint was revision for any reason, the survival estimates were 81% to 92% for the same implants at ten years. Aseptic loosening, wear, osteolysis and dislocation were the main reasons for the relatively poor overall performance of the acetabular components. Prostheses with alumina heads performed slightly better than those with stainless steel or CoCr alloy in subgroups. Whereas most acetabular components performed well at seven years, the survivorship declined with longer follow-up. Fixation was generally good. None of the metal-backed uncemented acetabular components with ultra-high-molecular-weight polyethylene liners in our study had satisfactory long-term results because of high rates of wear, osteolysis, aseptic loosening and dislocation.

  19. The influence of the oscillation angle and the neck anteversion of the prosthesis on the cup safe-zone that fulfills the criteria for range of motion in total hip replacements. The required oscillation angle for an acceptable cup safe-zone.

    PubMed

    Yoshimine, Fumihiro

    2005-01-01

    A normal hip joint has more than 120 degrees flexion. The reduced range of motion (ROM) of total hip arthroplast leads to frequent prosthetic impingement, subluxation and dislocation. Prosthetic impingement may be more serious for metal-on-metal and ceramic-on-ceramic total hip prosthesis (THP). A larger oscillation angle of THP (OsA) and proper cup and neck positions make a larger theoretical ROM of a patient's artificial hip joint. But what OsA is required and what range of cup positions is kinetically accepted are not clearly understood. A ROM of more than 120 degrees flexion, 45 degrees internal-rotation at 90 degrees flexion, 30 degrees extension and 40 degrees external-rotation was defined as severe criteria for an acceptable ROM. Theoretical cup safe-zones were created that fulfill the severe criteria of ROM for (OsA=110 degrees , 120 degrees , 135 degrees ) by the mathematical formulas. The size of the cup safe-zone mainly depends on the size of the OsA. There is no cup safe-zone for 110 degrees OsA, an extremely small safe-zone for 120 degrees OsA and an acceptable safe-zone for 135 degrees OsA. Each THP has its own OsA, because OsA is the function of head and neck diameter and cup design. More than 135 degrees OsA enlarges the safe-zone of the prosthetic position, so it extends the acceptable range of error that surgeons cannot avoid completely. However, few THPs with more than 135 degrees OsA are currently clinically available. Both surgeons and manufacturers must realize that OsA is as essential as cup and neck orientations for ROM.

  20. Acetabular Reconstruction with Human and Bovine Freeze- Dried Bone Grafts and a Reinforcement Device

    PubMed Central

    Rosito, Ricardo; Galia, Carlos Roberto; Macedo, Carlos Alberto Souza; Moreira, Luis Fernando; Quaresma, Lourdes Maria Araújo C.; Palma, Humberto Moreira

    2008-01-01

    BACKGROUND This is a cohort trial (1997–2005) of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG) and a reinforcement device. OBJECTIVE To compare clinical/radiographic graft incorporation capability between cancellous bone grafts. PATIENTS/METHODS There were two groups: I (n=26) receiving human grafts and II (n=25) receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d’Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn’s et al. criteria for radiographic bone incorporation. RESULTS No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424). CONCLUSION The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty. PMID:18719763

  1. Preliminary analysis on the MD-4® plasma-sprayed titanium acetabular component☆

    PubMed Central

    de Araújo Loures, Elmano; Simoni, Leandro Furtado; Leite, Isabel Cristina Gonçalves; Loures, Daniel Naya; Loures, Clarice Naya

    2015-01-01

    Objectives To evaluate the short-term performance of a type of implant manufactured in Brazil. Methods This study analyzed a cohort of 60 patients who underwent implantation of MD-4® acetabular components during primary hip arthroplasty procedures performed between January 1, 2010, and August 1, 2012. The patients were studied retrospectively with regard to clinical behavior, stability and radiological osseointegration. The patients were followed up for a minimum of 12 months and a maximum of 42 months (mean: 27) and were evaluated by means of the Harris Hip Score, SF-36 questionnaire and serial conventional radiographs. Results All the components were radiologically stable, without evidence of migration or progressive radiolucency lines. On average, the Harris Hip Score evolved from 36.1 to 92.1 (p < 0.001) and the SF-36 showed significant increases in all its domains (p < 0.001). No differences were observed among patients with osteoarthrosis, osteonecrosis, hip dysplasia or other conditions. Conclusions The short-term results showed clinical and radiological signs of stability and osseointegration of the implants, which may represent a predictive factor regarding medium-term survival of this acetabular component. PMID:26229918

  2. Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear

    PubMed Central

    Looney, R John; Boyd, Allen; Totterman, Saara; Seo, Gwy-Suk; Tamez-Pena, Jose; Campbell, Debbie; Novotny, Leonore; Olcott, Christopher; Martell, John; Hayes, F Ann; O'Keefe, Regis J; Schwarz, Edward M

    2002-01-01

    Osteolysis, which is considered to be a major source of morbidity following total hip joint replacement, has been notoriously difficult to measure accurately, particularly in the acetabular area. In order to study periacetabular osteolysis, specialized software for computerized tomography (CT) scan image analysis has been developed. This software (3D-CT) eliminates metal artifacts, allows three-dimensional segmentation of the CT image, and reconstructs the segmented image to provide an accurate representation and measurement of volume for osteolytic lesions. In the present study, 20 patients underwent periacetabular osteolytic volume determination using 3D-CT, functional assessment (using the Harris Hip Scale, the Western Ontario and McMaster University Osteoarthritis Index, and the short form 36 questionnaire), and two-dimensional analysis of volumetic polyethylene wear using digitalized plain films. Periacetabular osteolysis correlated directly with the polyethylene wear rate (relative risk [RR] = 0.494, P = 0.027). If one patient with an acetabular revision, one patient with recurrent dislocation, and one patient with a Biomet prosthesis are excluded, then the correlation between wear and osteolysis is improved (RR = 0.685, P = 0.002). In summary, the current study demonstrates both the feasibility of CT imaging of periacetabular osteolysis and the correlation between polyethylene wear and osteolytic volume, providing a potential outcome measure for clinical trials that are designed to examine interventions in this complex disease process. PMID:11879538

  3. Fatigue failure in the cement mantle of a simplified acetabular replacement model

    PubMed Central

    Zant, Nikolaus P.; Wong, Charles K.Y.; Tong, Jie

    2007-01-01

    Although the role of fatigue failure in aseptic loosening of cemented total hip replacements has been extensively studied in femoral components, studies of fatigue failure in cement mantle of acetabular replacements have yet to be reported, despite that the long-term failure rate in the latter is about three times that of femoral components. Part of the reason may be that a complex pelvic bone structure does not land itself readily for a 2D representation as that of a femur. In this work, a simple multilayer model has been developed to reproduce the stress distributions in the cement mantle of an acetabular replacement from a plane strain finite element pelvic bone model. The experimental multilayer model was subjected to cyclic loading up to peak hip contact force during normal walking. Radial fatigue cracks were observed in the vicinity of the maximum tangential and compressive stresses, as predicted by the FE models. Typical fatigue striations were also observed on the fracture surfaces post cyclic testing. The results were examined in the context of retrieval studies, 3D FE analysis and in vitro experimental results using full-sized hemi-pelvic bone models. PMID:19330048

  4. Towards the optimal design of an uncemented acetabular component using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Ghosh, Rajesh; Pratihar, Dilip Kumar; Gupta, Sanjay

    2015-12-01

    Aseptic loosening of the acetabular component (hemispherical socket of the pelvic bone) has been mainly attributed to bone resorption and excessive generation of wear particle debris. The aim of this study was to determine optimal design parameters for the acetabular component that would minimize bone resorption and volumetric wear. Three-dimensional finite element models of intact and implanted pelvises were developed using data from computed tomography scans. A multi-objective optimization problem was formulated and solved using a genetic algorithm. A combination of suitable implant material and corresponding set of optimal thicknesses of the component was obtained from the Pareto-optimal front of solutions. The ultra-high-molecular-weight polyethylene (UHMWPE) component generated considerably greater volumetric wear but lower bone density loss compared to carbon-fibre reinforced polyetheretherketone (CFR-PEEK) and ceramic. CFR-PEEK was located in the range between ceramic and UHMWPE. Although ceramic appeared to be a viable alternative to cobalt-chromium-molybdenum alloy, CFR-PEEK seems to be the most promising alternative material.

  5. Urine cup for collection of urine from cows.

    PubMed

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  6. A novel cupping-assisted plasma treatment for skin disinfection

    NASA Astrophysics Data System (ADS)

    Xiong, Zilan; Graves, David B.

    2017-02-01

    A novel plasma treatment method/plasma source called cupping-assisted plasma treatment/source for skin disinfection is introduced. The idea combines ancient Chinese ‘cupping’ technology with plasma sources to generate active plasma inside an isolated, pressure-controlled chamber attached to the skin. Advantages of lower pressure include reducing the threshold voltage for plasma ignition and improving the spatial uniformity of the plasma treatment. In addition, with reduced pressure inside the cup, skin pore permeability might be increased and it improves attachment of the plasma device to the skin. Moreover, at a given pressure, plasma-generated active species are restricted inside the cup, raising local reactive species concentration and enhancing the measured surface disinfection rate. A surface micro-discharge (SMD) device is used as an example of a working plasma source. We report discharge characteristics and disinfection efficiency as a function of pressure and applied voltage.

  7. The response function of modulated grid Faraday cup plasma instruments

    NASA Astrophysics Data System (ADS)

    Barnett, A.; Olbert, S.

    Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager Plasma Science (PLS) experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. The theoretical formulas were tested by multi-sensor analysis of solar wind data. The tests indicate that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.

  8. The response function of modulated grid Faraday cup plasma instruments

    NASA Technical Reports Server (NTRS)

    Barnett, A.; Olbert, S.

    1986-01-01

    Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager Plasma Science (PLS) experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. The theoretical formulas were tested by multi-sensor analysis of solar wind data. The tests indicate that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.

  9. Measuring Mean Cup Depth in the Optic Nerve Head

    PubMed Central

    Johnstone, John K.; Rhodes, Lindsay; Fazio, Massimo; Smith, Brandon; Wang, Lan; Downs, J. Crawford; Owsley, Cynthia; Girkin, Christopher A.

    2016-01-01

    Since the deformation of structures in the optic nerve head (ONH) is associated with glaucoma and other diseases of the optic nerve, measurement of this deformation is of current research interest. This paper considers the computation of cup depth, a measurement of the depth of the internal limiting membrane (ILM). The computation of cup depth requires a reference structure against which to measure the ILM, and the construction of two reference structures is discussed, one based on Bruch's membrane opening (BMO) and the other based on the anterior surface of the peripapillary sclera (AS). A main focus of the paper is the robust computation of mean cup depth, which requires a good sampling of a reconstruction of the ILM surface. To evaluate our algorithm, the construction of synthetic datasets is considered. PMID:27942258

  10. Earliest Directly-Dated Human Skull-Cups

    PubMed Central

    Bello, Silvia M.; Parfitt, Simon A.; Stringer, Chris B.

    2011-01-01

    Background The use of human braincases as drinking cups and containers has extensive historic and ethnographic documentation, but archaeological examples are extremely rare. In the Upper Palaeolithic of western Europe, cut-marked and broken human bones are widespread in the Magdalenian (∼15 to 12,000 years BP) and skull-cup preparation is an element of this tradition. Principal Findings Here we describe the post-mortem processing of human heads at the Upper Palaeolithic site of Gough's Cave (Somerset, England) and identify a range of modifications associated with the production of skull-cups. New analyses of human remains from Gough's Cave demonstrate the skilled post-mortem manipulation of human bodies. Results of the research suggest the processing of cadavers for the consumption of body tissues (bone marrow), accompanied by meticulous shaping of cranial vaults. The distribution of cut-marks and percussion features indicates that the skulls were scrupulously 'cleaned' of any soft tissues, and subsequently modified by controlled removal of the facial region and breakage of the cranial base along a sub-horizontal plane. The vaults were also ‘retouched’, possibly to make the broken edges more regular. This manipulation suggests the shaping of skulls to produce skull-cups. Conclusions Three skull-cups have been identified amongst the human bones from Gough's Cave. New ultrafiltered radiocarbon determinations provide direct dates of about 14,700 cal BP, making these the oldest directly dated skull-cups and the only examples known from the British Isles. PMID:21359211

  11. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  12. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  13. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  14. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  15. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  16. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  17. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  18. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  19. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  20. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  1. Grouped retinae and tapetal cups in some Teleostian fish: occurrence, structure, and function.

    PubMed

    Francke, Mike; Kreysing, Moritz; Mack, Andreas; Engelmann, Jacob; Karl, Anett; Makarov, Felix; Guck, Jochen; Kolle, Mathias; Wolburg, Hartwig; Pusch, Roland; von der Emde, Gerhard; Schuster, Stefan; Wagner, Hans-Joachim; Reichenbach, Andreas

    2014-01-01

    representing the usual environmental conditions of the fish, the outer segments of up to 30 cone cells are placed at the bottom of the cup where light intensity is maximized. Strikingly, however, a large number of rod receptor cells are positioned behind each mirroring cup. This peculiar arrangement (i) allows vision at deep red wavelenghts, (ii) matches the sensitivity of rod and cone photoreceptors, and (iii) facilitates the detection of low-contrast and color-mixed stimuli, within the dim, turbid habitat. Thus, for these fish the grouped retina appears to aid in reliable and quick detection of large, fast moving, biologically relevant stimuli such as predators. Overall, the grouped retina appears as a peculiar type of general retinal specialization in a variety of fish species that is adaptive in particular habitats such as turbid freshwater but also the deep-sea. The authors were prompted to write this review by working on the retina of Gnathonemus petersii; the data resulting from this work (Landsberger et al., 2008; Kreying et al., 2012) are included in the present review.

  2. Calibration and Lag of a Friez Type Cup Anemometer

    NASA Technical Reports Server (NTRS)

    Pinkerton, Robert M

    1930-01-01

    Tests on a Friez type cup anemometer have been made in the variable density wind tunnel of the Langley Memorial Aeronautical Laboratory to calibrate the instrument and to determine its suitability for velocity measurements of wind gusts. The instrument was calibrated against a Pitot-static tube placed directly above the anemometer at air densities corresponding to sea level, and to an altitude of approximately 6000 feet. Air-speed acceleration tests were made to determine the lag in the instrument reading. The calibration results indicate that there should be an altitude correction. It is concluded that the cup anemometer is too sluggish for velocity measurements of wind gusts.

  3. Mode-bifurcation upon pouring water into a cup that depends on the shape of the cup

    NASA Astrophysics Data System (ADS)

    Nakata, Satoshi; Yamada, Akiko; Kitahata, Hiroyuki

    2005-05-01

    Mode-bifurcation that included hysteresis was investigated when water was poured into a cup via a water faucet. Three modes, i.e., accumulation flow (mode I), scattering flow (mode II), and open and shut oscillatory flow (mode III), could be produced by laterally changing the distance between the center of the cup and the landing point of water poured at a constant flow rate. Hysteresis in mode-bifurcation was observed when the distance was changed depending on the initial location of the water poured into the cup. Pendulum flow was also observed when water was poured into a shallow cell. The essential features of this mode-switching were reproduced by a numerical calculation as a function of the landing point of the poured water using two-variable (the size of the water hollow and the pressure on the water surface) differential equations that included the nature of reversed flow.

  4. Effect of methotrexate exposure at middle gestation on the inner plate of the ocular cup and lens in the rat fetus

    PubMed Central

    Zu, Cheng Zhe; Kuroki, Masato; Hirako, Ayano; Takeuchi, Takashi; Furukawa, Satoshi; Sugiyama, Akihiko

    2016-01-01

    Pregnant rats were treated intraperitoneally with a single dose of methotrexate (MTX) 90 mg/kg on gestation day (GD) 13, and fetal eyeballs were examined time-dependently from GD 13.5 to 15.5. Throughout the experimental period, the inner plate of the ocular cup in the MTX group was significantly thinner than that in the control group. In the inner plate of the ocular cup on GD 15 and 15.5, whereas a developed ganglion cell layer was observed in the control group, the ganglion cell layer in the MTX group was undeveloped and indistinguishable. Disturbance of the arrangement of lens fiber cells, narrowing of the hyaloid cavity of the optic cup, and hypoplasia of optic nerve fibers were observed in the MTX group on GD 15 and 15.5. Increase of pyknosis and decrease of mitosis were induced in the optic cup and the lens epithelium of the MTX group. In the inner plate of the optic cup and the lens epithelium of the MTX group, the cleaved caspase-3- and TUNEL-positive rates increased significantly throughout the experimental period. The phospho-histone H3-positive rate in the inner plate of the optic cup decreased significantly from GD 13.5 to 14.5, and it recovered on GD 15. On the other hand, the phospho-histone H3-positive rate in the lens epithelium decreased significantly throughout the experimental period. These results suggested that optic tissue on GD 13 in rats was sensitive to MTX. PMID:27559242

  5. Clinical fracture of cross-linked UHMWPE acetabular liners.

    PubMed

    Furmanski, Jevan; Anderson, Martin; Bal, Sonny; Greenwald, A Seth; Halley, David; Penenberg, Brad; Ries, Michael; Pruitt, Lisa

    2009-10-01

    Highly cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is increasingly used as a bearing material in total hip replacements. Cross-linking of UHMWPE has been shown to increase wear resistance but decrease its fracture resistance. We analyzed the clinical fracture failure of four cross-linked UHMWPE total hip replacement components of four different designs via microscopic observation of the fracture surfaces, and found that in all cases fractures initiated at stress concentrations in an unsupported region of the component (termed the elevated rim). Finite element analyses (FEA) of each individual implant design were then conducted. Results from this analysis demonstrated that the predicted magnitude and orientation of maximum principal stress due to mechanical loading of the elevated rim was sufficient to propagate initiated fatigue cracks in each case. FEA also predicted that cracks may arrest after some amount of growth due to a steep stress gradient near the initiation site. Further, while anatomical positioning of the implant and material properties affect the risk of fracture, we examined whether these failures are strongly related to the notched elevated rim design feature that is common to the four failed cases presented here. We believe that cross-linked UHMWPE remains an excellent bearing material for total hip replacements but that designs employing this material should mitigate stress concentrations or other design features that increase the risk of fracture.

  6. 78 FR 37712 - Safety Zone; Chicago Match Cup Race; Lake Michigan; Chicago, IL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... SECURITY Coast Guard 33 CFR Part 165 Safety Zone; Chicago Match Cup Race; Lake Michigan; Chicago, IL AGENCY... safety zone on Lake Michigan near Chicago, Illinois for the 2013 AWMRT Chicago Match Cup Race. This zone... Chicago Match Cup. During the aforementioned periods, the Coast Guard will enforce restrictions upon,...

  7. 77 FR 7025 - Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zones; America's Cup World Series, East Passage... Bay, Rhode Island, during the America's Cup World Series sailing vessel racing event. This safety zone... and spectators involved with the America's Cup World Series in the vicinity of Newport, RI....

  8. 77 FR 28253 - Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; America's Cup World Series, East Passage... the America's Cup World Series (ACWS) sailing vessel racing event. DATES: This rule is effective June..., we published a notice of proposed rulemaking (NPRM) entitled ``Safety Zones; America's Cup...

  9. 77 FR 54815 - Safety Zone: America's Cup World Series Regattas, San Francisco Bay; San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone: America's Cup World Series Regattas, San... Alcatraz Island. This rule will regulate the on-water activities associated with 2012 America's Cup World... Cup World Series regattas as part of a circuit of sailing events being conducted at other U.S....

  10. 77 FR 60897 - Safety Zone: America's Cup World Series Finish-Line, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone: America's Cup World Series Finish-Line, San... support of the 2012 America's Cup World Series sailing events. This safety zone is established to ensure..., through Sunday, October 7, 2012, for the 2012 America's Cup World Series. The Coast Guard intends...

  11. 78 FR 40396 - Safety Zone; America's Cup Safety Zone and No Loitering Area, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-05

    ...,'' ``Red Bull Youth America's Cup,'' and ``America's Cup Finals Match'' scheduled to occur in July, August... associated with the viewing of the America's Cup in vicinity of buoys ``1'' and ``2'', marking the deep water... will not retaliate against small entities that question or complain about this rule or any policy...

  12. Cup Stacking: Does It Deserve a Place in Physical Education Curricula?

    ERIC Educational Resources Information Center

    Udermann, Brian E.; Murray, Steven R.

    2006-01-01

    Cup stacking has become commonplace in today's physical education nomenclature. Proponents make claims that cup stacking improves cognitive, affective, and psychomotor abilities. At physical education conferences, scores of professional physical educators eagerly watch cup stacking representatives construct and deconstruct a variety of pyramids…

  13. Plastic Straining of Iridium Alloy DOP-26 During Cup Sizing Operations

    SciTech Connect

    Ohriner, Evan Keith; Ulrich, George B; Sabau, Adrian S

    2007-09-01

    DOP-26 iridium alloy cups are used for fuel cladding for radioisotope power systems. The cups are deep drawn and recrystallized prior to final fabrication operations. This study characterizes the plastic deformation of cups during a sizing operation following the recrystallization heat treatment. The purpose of the sizing operation is to achieve the specified roundness, diameter, and radius dimensions of the cup. The operation introduces various levels of plastic strain in the cup. Plastic strain can be a cause of inhomogeneous or abnormal grain growth during subsequent exposure to elevated temperature during the service life of the fueled clad. This is particularly true in the case of cups which have irregularities in the cup walls from the deep drawing operations. Diameter and roundness measurements were made on two cups both before and after sizing. Plastic strain levels were calculated using the ABAQUSTM finite element software. The calculated plastic strain levels in both cups were below 0.025, a value shown to be below the critical strain for abnormal grain growth during a simulated service exposure. The calculated maximum plastic strain was found to increase with increased applied sizing load and was not sensitive to the input value for the clearance between the cup and the sizing die. The calculated geometry of the sized cups was in good agreement with the measurements on the finished cups.

  14. 33 CFR 165.T11-0551 - Safety Zone; America's Cup Sailing Events.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Sailing Events. 165.T11-0551 Section 165.T11-0551 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... § 165.T11-0551 Safety Zone; America's Cup Sailing Events. (a) Definitions—(1) America's Cup Racing... 34th America's Cup sailing events. (2) Patrol Commander. As used in this section, “Patrol Commander”...

  15. 77 FR 22706 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ... the ``America's Cup World Series,'' the ``Louis Vuitton Cup'' challenger selection series, and the ``America's Cup Finals Match'' sailing regattas that may be conducted in the waters of San Francisco Bay... SECURITY Coast Guard 33 CFR Parts 100 and 165 Special Local Regulation and Safety Zone; America's...

  16. 77 FR 46285 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-03

    ... associated with the ``2012 America's Cup World Series'' regatta scheduled for August 21-26, 2012, on the... zone regulate the on-water activities associated with the ``2012 America's Cup World Series'' regatta... published in association with the ``2012 America's Cup World Series'' regattas. This program calendar...

  17. 75 FR 39448 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit... Detroit River during the Detroit APBA Gold Cup. This special local regulation is necessary to protect... rulemaking (NPRM) entitled Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI in...

  18. 75 FR 21191 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-23

    ... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit... vessels from portions of the Detroit River during the Detroit APBA Gold Cup. This special local regulation..., testing and race in conjunction with the Detroit APBA Gold Cup. The powerboat race and associated...

  19. Leidos Reclaims Defelice Cup at Annual Golf Tournament | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer Leidos Biomedical Research reclaimed the Defelice Cup trophy from NCI at the eighth annual Ronald H. Defelice golf tournament, held October 14. The final score was 15–7, with Leidos Biomed tying the series 4 to 4. Fourteen players on each team battled it out at Rattlewood golf course in Mount Airy, Md.

  20. Injuries among World Cup ski and snowboard athletes.

    PubMed

    Flørenes, T W; Nordsletten, L; Heir, S; Bahr, R

    2012-02-01

    There is little information available on injuries to World Cup skiers and snowboarders. The aim of this study was to describe and compare the injury risk to World Cup athletes in alpine skiing, freestyle skiing, snowboarding, ski jumping, Nordic combined and cross country skiing. We performed retrospective interviews with the International Ski Federation (FIS) World Cup athletes from selected nations during the 2006-2007 and 2007-2008 winter seasons and recorded all acute injuries occurring during the seasons. We interviewed 2121 athletes and recorded 705 injuries. There were 520 (72%) time-loss injuries and 196 (28%) severe injuries (absence >28 days). In freestyle skiing, alpine skiing and snowboarding, there were 27.6, 29.8 and 37.8 time-loss and 14.4, 11.3 and 13.8 severe injuries per 100 athletes per season, respectively. In Nordic combined, ski jumping and cross country skiing, there were 15.8, 13.6 and 6.3 time-loss and 3.3, 5.6 and 0.7 severe injuries per 100 athletes per season, respectively. In conclusion about 1/3 of the World Cup alpine, freestyle and snowboard athletes sustain a time-loss injury each season, while the risk is low in the Nordic disciplines. A particular concern was the high proportion of severe injuries observed among alpine, freestyle and snowboard athletes, which is in contrast to most other sports.

  1. Our Everyday Cup of Coffee: The Chemistry behind Its Magic

    ERIC Educational Resources Information Center

    Petracco, Marino

    2005-01-01

    Coffee consumption has spread worldwide and differences in the raw bean consumption, in roasting conditions and in the extraction procedures used to prepare coffee brews result in a great diversity of chemical composition in the final product, the cup of coffee. Hence, beverage preparation is a fundamental step for enjoying the benefits of this…

  2. Microindentation hardness evaluation of iridium alloy clad vent set cups

    NASA Astrophysics Data System (ADS)

    Ulrich, George B.; DeRoos, Larry F.; Stinnette, Samuel E.

    1993-01-01

    An iridium alloy, DOP-26, is used as cladding for 238PuO2 fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  3. Teaching Transport Phenomena around a Cup of Coffee

    ERIC Educational Resources Information Center

    Condoret, Jean Stephane

    2007-01-01

    The very common situation of waiting for the cooling of a cup of coffee is addressed through a conventional engineering approach, where several important concepts of heat and mass transfer are used. A numerical and analytical solution of the differential equations of the problem are proposed, and assessed by comparing to simple experiments.…

  4. Microindentation hardness evaluation of iridium alloy clad vent set cups

    SciTech Connect

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E. )

    1993-01-15

    An iridium alloy, DOP-26, is used as cladding for [sup 238]PuO[sub 2] fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  5. Microindentation hardness evaluation of iridium alloy clad vent set cups

    SciTech Connect

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1992-05-15

    An iridium alloy, DOP-26, is used as cladding for {sup 238}PuO{sup 2} fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration`s Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  6. Microindentation hardness evaluation of iridium alloy clad vent set cups

    SciTech Connect

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1992-05-15

    An iridium alloy, DOP-26, is used as cladding for {sup 238}PuO{sup 2} fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  7. NASCAR Winston Cup Race Results for 1975-2003

    ERIC Educational Resources Information Center

    Winner, Larry

    2006-01-01

    Stock car racing has seen tremendous growth in popularity in recent years. We introduce two datasets containing results from all Winston Cup races between 1975 and 2003, inclusive. Students can use any number of statistical methods and applications of basic probability on the data to answer a wide range of practical questions. Instructors and…

  8. Technology. The Hot Cup Caper. Probing for Scientific Knowledge.

    ERIC Educational Resources Information Center

    Ramondetta, June

    1994-01-01

    Students can explore temperature and heat conductivity by examining materials that make good cups for hot cocoa. Using temperature probes from computer-based science packages, students can measure gradual change in the liquid's temperature, watch as data are plotted on the computer, and explain why they chose a specific material. (SM)

  9. Extremely high fracture rate of a modular acetabular component with a sandwich polyethylene ceramic insertion for THA: a preliminary report.

    PubMed

    Kircher, Jörn; Bader, Rainer; Schroeder, Bettina; Mittelmeier, Wolfram

    2009-09-01

    Improvements of ceramic components and design changes have reduced failure rates over the past 30 years in total hip arthroplasty. We present a series of n = 11 cases with ceramic failure out of n = 113 implantations, from which n = 66 were ceramic-on-ceramic (n = 50 with ceramic insert with sandwich in polyethylene and n = 16 with directly fixed ceramic inlay) and n = 47 ceramic on polyethylene bearings, between 1999 and 2001 after introduction of a new implantation system to the market. The overall fracture rate of ceramic for the whole series (n = 113) was 9.7%. For the combination ceramic head with UHMW-PE (n = 47) the fracture rate was 2.1%. For the combination ceramic with ceramic (n = 66) the fracture rate was 15.2%. For the combination ceramic with ceramic sandwich in PE (n = 50) the failure rate was 18%. Only three patients experienced a trauma. Demography of patients (age, gender, body weight and BMI) was not statistically different between patients with failed ceramics and the rest of the patients making patient-specific risk factors unlikely to be an explanation for the failures. Retrospective X-ray analysis of the cup positioning did not show significant difference between failed and non-failed implants in terms of mean cup inclination and version making also operation-specific factors unlikely to be the only reason of this high failure rate. Therefore, manufacturer-specific factors such as design features may have contributed to this high failure rate. Further analysis of the whole series with biomechanical testing of the retrieved material needs to be performed.

  10. Expression of Pseudomonas aeruginosa CupD Fimbrial Genes Is Antagonistically Controlled by RcsB and the EAL-Containing PvrR Response Regulators

    PubMed Central

    Mikkelsen, Helga; Ball, Geneviève; Giraud, Caroline; Filloux, Alain

    2009-01-01

    Pseudomonas aeruginosa is a gram-negative pathogenic bacterium with a high adaptive potential that allows proliferation in a broad range of hosts or niches. It is also the causative agent of both acute and chronic biofilm-related infections in humans. Three cup gene clusters (cupA-C), involved in the assembly of cell surface fimbriae, have been shown to be involved in biofilm formation by the P. aeruginosa strains PAO1 or PAK. In PA14 isolates, a fourth cluster, named cupD, was identified within a pathogenicity island, PAPI-I, and may contribute to the higher virulence of this strain. Expression of the cupA genes is controlled by the HNS-like protein MvaT, whereas the cupB and cupC genes are under the control of the RocS1A1R two-component system. In this study, we show that cupD gene expression is positively controlled by the response regulator RcsB. As a consequence, CupD fimbriae are assembled on the cell surface, which results in a number of phenotypes such as a small colony morphotype, increased biofilm formation and decreased motility. These behaviors are compatible with the sessile bacterial lifestyle. The balance between planktonic and sessile lifestyles is known to be linked to the intracellular levels of c-di-GMP with high levels favoring biofilm formation. We showed that the EAL domain-containing PvrR response regulator counteracts the activity of RcsB on cupD gene expression. The action of PvrR is likely to involve c-di-GMP degradation through phosphodiesterase activity, confirming the key role of this second messenger in the balance between bacterial lifestyles. The regulatory network between RcsB and PvrR remains to be elucidated, but it stands as a potential model system to study how the equilibrium between the two lifestyles could be influenced by therapeutic agents that favor the planktonic lifestyle. This would render the pathogen accessible for the immune system or conventional antibiotic treatment. PMID:19547710

  11. [Mountainbike injuries in world-cup and recreational athletes].

    PubMed

    Himmelreich, H; Pralle, H; Vogt, L; Banzer, W

    2007-12-01

    This study investigated the incidence and frequency of injuries in mountainbike sports among competitive and recreational athletes. In a retrospective study design mountain-bike athletes were interviewed by means of a standardized questionnaire with regard to sports injuries and damages within the previous two years. The evaluation of time relative injury-rate was carried out under consideration of class and competition discipline. 75 % of the distributed questionnaires returned completed by 106 World-Cup (39 female symbol 67 male symbol, 23.1 y) and 134 recreational athletes (17 female symbol 117 male symbol, 27.4 y). Approximately 80 % of the World-Cup and about 50 % of the recreational athletes reported about at least one severe injury. World-Cup downhill athletes (1.08 injuries/ 1000 h) show a more than doubled time-related injury-rate in comparison with Cross-Country athletes (0.39 injuries/ 1000 h). Injuries of the lower (47 vs. 35 %) and upper extremity (40 vs. 41 %) show comparable prevalence for competitive and recreational cyclists. In the group of recreational athletes open wounds dominate, competitive athletes demonstrate a significant higher fracture-rate (p < 0.01). Within the World-Cup athletes head injuries stand out (n = 40). Although World-Cup participation does not result in essential injury-increase, the downhill discipline is characterized by a higher injury risk. Presumably in view of the performance orientation, there is a higher degree of risk readiness. Despite the riding performance and the obligatory safety equipment a remarkable number of bone and head injuries results.

  12. A confirmed case of toxic shock syndrome associated with the use of a menstrual cup.

    PubMed

    Mitchell, Michael A; Bisch, Steve; Arntfield, Shannon; Hosseini-Moghaddam, Seyed M

    2015-01-01

    Menstrual cups have been reported to be an acceptable substitute for tampons. These flexible cups have also been reported to provide a sustainable solution to menstrual management, with modest cost savings and no significant health risk. The present article documents the first case of toxic shock syndrome associated with the use of a menstrual cup in a woman 37 years of age, using a menstrual cup for the first time. Toxic shock syndrome and the literature on menstrual cups is reviewed and a possible mechanism for the development of toxic shock syndrome in the patient is described.

  13. The acetabular labrum: anatomic and functional characteristics and rationale for surgical intervention.

    PubMed

    Safran, Marc R

    2010-06-01

    The past decade has seen unprecedented growth in the number of hip arthroscopies. Acetabular labral tears are the leading indication for arthroscopy of this joint. However, labral anatomy and function, as well as the effects of labral tears and surgical outcomes, have only recently been studied. Labral tears may cause pain and microinstability of the hip joint. They also may increase friction within the joint, cartilage consolidation, and strain within the articular cartilage, thereby possibly resulting in accelerated degeneration of the joint. Partial labrectomy and labral repair are the current surgical options, and basic science data suggest that labral repairs can heal and subsequently restore function. However, a good, validated outcomes measure to adequately assess active patients with a painful nonarthritic hip is needed to determine the efficacy of such repair and aid in managing patient expectations.

  14. A feasibility study into the use of three-dimensional printer modelling in acetabular fracture surgery.

    PubMed

    Yu, A W; Duncan, J M; Daurka, J S; Lewis, A; Cobb, J

    2015-01-01

    There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient's unique anatomy can only lead to improved outcomes.

  15. Prophylactic radiotherapy against heterotopic ossification following internal fixation of acetabular fractures: a comparative estimate of risk

    PubMed Central

    Nasr, P; Yip, G; Scaife, J E; House, T; Thomas, S J; Harris, F; Owen, P J; Hull, P

    2014-01-01

    Objective: Radiotherapy (RT) is effective in preventing heterotopic ossification (HO) around acetabular fractures requiring surgical reconstruction. We audited outcomes and estimated risks from RT prophylaxis, and alternatives of indometacin or no prophylaxis. Methods: 34 patients underwent reconstruction of acetabular fractures through a posterior approach, followed by a 8-Gy single fraction. The mean age was 44 years. The mean time from surgery to RT was 1.1 days. The major RT risk is radiation-induced fatal cancer. The International Commission on Radiological Protection (ICRP) method was used to estimate risk, and compared with a method (Trott and Kemprad) specifically for estimating RT risk for benign disease. These were compared with risks associated with indometacin and no prophylaxis. Results: 28 patients (82%) developed no HO; 6 developed Brooker Class I; and none developed Class II–IV HO. The ICRP method suggests a risk of fatal cancer in the range of 1 in 1000 to 1 in 10,000; the Trott and Kemprad method suggests 1 in 3000. For younger patients, this may rise to 1 in 2000; and for elderly patients, it may fall to 1 in 6000. The risk of death from gastric bleeding or perforation from indometacin is 1 in 180 to 1 in 900 in older patients. Without prophylaxis risk of death from reoperation to remove HO is 1 in 4000 to 1 in 30,000. Conclusion: These results are encouraging, consistent with much larger series and endorse our multidisciplinary management. Risk estimates can be used in discussion with patients. Advances in knowledge: The risk from RT prophylaxis is small, it is safer than indometacin and substantially overlaps with the range for no prophylaxis. PMID:25089852

  16. Acetabular revision with impaction bone grafting and a cemented polyethylene acetabular component: comparison of the Kaplan-Meier analysis to the competing risk analysis in 62 revisions with 25 to 30 years follow-up.

    PubMed

    Te Stroet, M A J; Keurentjes, J C; Rijnen, W H C; Gardeniers, J W M; Verdonschot, N; Slooff, T J J H; Schreurs, B W

    2015-10-01

    We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). We performed Kaplan-Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint 're-revision for any reason' was 58.0% (95% confidence interval (CI) 38 to 73) and for 're-revision for aseptic loosening' 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years.

  17. An Effective and Feasible Method, “Hammering Technique,” for Percutaneous Fixation of Anterior Column Acetabular Fracture

    PubMed Central

    Zhang, Lihai; Zhang, Wei; Li, Tongtong; Li, Jiantao; Chen, Hua

    2016-01-01

    Objective. The objective of this study was to evaluate the effectiveness and advantages of percutaneous fixation of anterior column acetabular fracture with “hammering technique.” Materials and Methods. We retrospectively reviewed 16 patients with percutaneous fixation of anterior column acetabular fracture with “hammering technique.” There were 11 males and 5 females with an average age of 38.88 years (range: 24–54 years) in our study. Our study included 7 nondisplaced fractures, 6 mild displaced fractures (<2 mm), and 5 displaced fractures (>2 mm). The mean time from injury to surgery was 4.5 days (range: 2–7 days). Results. The average of operation time was 27.56 minutes (range: 15–45 minutes), and the mean blood loss was 55.28 mL (range: 15–100 mL). The mean fluoroscopic time was 54.78 seconds (range: 40–77 seconds). The first pass of the guide wire was acceptable without cortical perforation or intra-articular perforation in 88.89% (16/18) of the procedures, and the second attempt was in 11.11% (2/18). Conclusion. Our study suggested that percutaneous fixation of anterior column acetabular fracture with “hammering technique” acquired satisfying surgical and clinical outcomes. It may be an alternative satisfying treatment for percutaneous fixation of anterior column acetabular fracture by 2D fluoroscopy using a C-arm with less fluoroscopic time. PMID:27493962

  18. Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim

    PubMed Central

    Bonneau, Noémie; Bouhallier, July; Baylac, Michel; Tardieu, Christine; Gagey, Olivier

    2012-01-01

    Understanding the three-dimensional orientation of the coxo-femoral joint remains a challenge as an accurate three-dimensional orientation ensure an efficient bipedal gait and posture. The quantification of the orientation of the acetabulum can be performed using the three-dimensional axis perpendicular to the plane that passes along the edge of the acetabular rim. However, the acetabular rim is not regular as an important indentation in the anterior rim was observed. An innovative cadaver study of the labrum was developed to shed light on the proper quantification of the three-dimensional orientation of the acetabulum. Dissections on 17 non-embalmed corpses were performed. Our results suggest that the acetabular rim is better represented by an anterior plane and a posterior plane rather than a single plane along the entire rim as it is currently assumed. The development of the socket from the Y-shaped cartilage was suggested to explain the different orientations in these anterior and posterior planes. The labrum forms a plane that takes an orientation in between the anterior and posterior parts of the acetabular rim, filling up inequalities of the bony rim. The vectors VL, VA2 and VP, representing the three-dimensional orientation of the labrum, the anterior rim and the posterior rim, are situated in a unique plane that appears biomechanically dependent. The three-dimensional orientation of the acetabulum is a fundamental parameter to understand the hip joint mechanism. Important applications for hip surgery and rehabilitation, as well as for physical anthropology, were discussed. PMID:22360458

  19. Sphere anemometer - a faster alternative solution to cup anemometry

    NASA Astrophysics Data System (ADS)

    Hölling, M.; Schulte, B.; Barth, S.; Peinke, J.

    2007-07-01

    We present an anemometer technique characterized by an instrument in a sealed enclosure without moving parts. Measurements taken with our improved sphere anemometer in comparison to cup anemometer and hot-wire anemometer data subjected to wind gusts are discussed. The hot-wire anemometer serves as a reference with high temporal and spacial resolution. A manually driven "gust generator" produced gusts at low frequencies of about 1Hz. All measurements were carried out in the wind tunnel at the University of Oldenburg.

  20. Epidemiology of injuries and illnesses in America's Cup yacht racing

    PubMed Central

    Neville, V J; Molloy, J; Brooks, J H M; Speedy, D B; Atkinson, G

    2006-01-01

    Objectives To determine the incidence and severity of injuries and illnesses incurred by a professional America's Cup yacht racing crew during the preparation for and participation in the challenge for the 2003 America's Cup. Methods A prospective study design was used over 74 weeks of sailing and training. All injuries and illnesses sustained by the 35 professional male crew members requiring medical treatment were recorded, including the diagnosis, nature, location, and mechanism of injury. The volume of sailing and training were recorded, and the severity of incidents were determined by the number of days absent from both sailing and training. Results In total, 220 injuries and 119 illnesses were recorded, with an overall incidence of 8.8 incidents/1000 sailing and training hours (injuries, 5.7; illnesses, 3.1). The upper limb was the most commonly injured body segment (40%), followed by the spine and neck (30%). The most common injuries were joint/ligament sprains (27%) and tendinopathies (20%). The incidence of injury was significantly higher in training (8.6) than sailing (2.2). The most common activity or mechanism of injury was non‐specific overuse (24%), followed by impact with boat hardware (15%) and weight training (13%). “Grinders” had the highest overall injury incidence (7.7), and “bowmen” had the highest incidence of sailing injuries (3.2). Most of the illnesses were upper respiratory tract infections (40%). Conclusions The data from this study suggest that America's Cup crew members are at a similar risk of injury to athletes in other non‐collision team sports. Prudent allocation of preventive and therapeutic resources, such as comprehensive health and medical care, well designed conditioning and nutritional programmes, and appropriate management of recovery should be adopted by America's Cup teams in order to reduce the risk of injury and illness. PMID:16556783

  1. A new approach for miniaturization of multiple faraday cup collectors.

    SciTech Connect

    Banar, J. C.; Chamberlin, E. P.; Poths, J.; Perrin, R. E.; Chastagner, P.

    2002-01-01

    The mass spectrometry section in CST-7 has been working for several years on a novel so0lution to overcome the size and placement restrictions of multiple Faraday cup collectors. Use of simultaneous collection of multiple isotopes both increases precision in the isotopic measurements and shortens the data collection time. Our application is for the measurement of the isotopic composition of Xe, ionized in a source that produces a large (10{sup -11} amp) but variable ion beam.

  2. From Tonic-cups to Bitter-cups: Kwasi bita beker from Suriname Determination, past and present use of an ancient galenic artefact.

    PubMed

    Odonne, G; Bourdy, G; Beauchêne, J; Houël, E; Stien, D; Chevolot, L; Deharo, E

    2007-03-21

    In the main markets of Paramaribo (Suriname), many stands offer what is locally called "Bitter-cups", or "Kwasi bita beker", small footed-cups, roughly carved from a whitish wood. The use of these cups is strictly medicinal and it seems to be restricted to Suriname, as they are not found in neighbouring countries (Guyana, French Guiana). The aim of this study was to identify the botanical origin of Bitter-cups still in use in the Saramaka traditional medicine (as information from field people was controversial), and document the ethnopharmacology of this original galenical artefact. Microscopic and high performance liquid chromatography (HPLC) analyses were carried out on Bitter-cup, and anatomical criteria (marginal parenchyma band, size of intervessel and vessel-ray pits, rays width and rays composition, vessels clustering, frequency and size of parenchyma pits) together with HPLC profiles of the macerates showed that the wood cup was similar to Quassia amara L. (Simaroubaceae) wood. Ethnopharmacological investigation indicates that the use of these cups is simply due to the pharmacological properties attributed to "bitters", and is strongly linked to tradition and cultural attitudes. This study also emphasizes the long lasting use of these cups, now restricted to Suriname only, with almost no variation over one century.

  3. Temporal and spatial distributions of directional counterface motion at the acetabular bearing surface in total hip arthroplasty.

    PubMed Central

    Pedersen, D. R.; Brown, T. D.; Maxian, T. A.; Callaghan, J. J.

    1998-01-01

    The motions of counterface articulation against the bearing surface of the acetabular liner strongly influence polyethylene wear debris production in contemporary total hip arthroplasty. However, the available body of relevant articular force and motion information is largely confined to resultant load excursions measured relative to instrumented femoral components, and/or to global angular motions (flexion, adduction, endorotation) of the joint. Analytical frameworks are here developed to transform such information into temporal and spatial variations of the resultant load and of the local counterface sliding velocity relative to an ordered set of discrete locations (e.g., finite element nodes) on the acetabular bearing surface. Whole-duty-cycle time histories of acetabular resultant load and counterface velocity distributions are presented for two important practical situations: human level walking gait, and a 23 degrees biaxial rocking hip simulation machine. The local counterface motions occurring in the simulator are characterized by higher velocities, smoother motion patterns, and wider directional variation than those occurring in human gait. PMID:9807707

  4. Development and first experimental tests of Faraday cup array.

    PubMed

    Prokůpek, J; Kaufman, J; Margarone, D; Krůs, M; Velyhan, A; Krása, J; Burris-Mog, T; Busold, S; Deppert, O; Cowan, T E; Korn, G

    2014-01-01

    A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry. This is a unique method for two-dimensional visualisation of ion currents from laser-generated plasmas. A technical description of the new type of Faraday cup is introduced along with an ad hoc data analysis procedure. Experimental results obtained during campaigns at the Petawatt High-Energy Laser for Heavy Ion Experiments (GSI, Darmstadt) and at the Prague Asterix Laser System (AS CR) are presented. Advantages and limitations of the used diagnostic system are discussed.

  5. Oxidative unzipping of stacked nitrogen-doped carbon nanotube cups.

    PubMed

    Dong, Haifeng; Zhao, Yong; Tang, Yifan; Burkert, Seth C; Star, Alexander

    2015-05-27

    We demonstrate a facile synthesis of different nanostructures by oxidative unzipping of stacked nitrogen-doped carbon nanotube cups (NCNCs). Depending on the initial number of stacked-cup segments, this method can yield graphene nanosheets (GNSs) or hybrid nanostructures comprised of graphene nanoribbons partially unzipped from a central nanotube core. Due to the stacked-cup structure of as-synthesized NCNCs, preventing complete exposure of graphitic planes, the unzipping mechanism is hindered, resulting in incomplete unzipping; however, individual, separated NCNCs are completely unzipped, yielding individual nitrogen-doped GNSs. Graphene-based materials have been employed as electrocatalysts for many important chemical reactions, and it has been proposed that increasing the reactive edges results in more efficient electrocatalysis. In this paper, we apply these graphene conjugates as electrocatalysts for the oxygen reduction reaction (ORR) to determine how the increase in reactive edges affects the electrocatalytic activity. This investigation introduces a new method for the improvement of ORR electrocatalysts by using nitrogen dopants more effectively, allowing for enhanced ORR performance with lower overall nitrogen content. Additionally, the GNSs were functionalized with gold nanoparticles (GNPs), resulting in a GNS/GNP hybrid, which shows efficient surface-enhanced Raman scattering and expands the scope of its application in advanced device fabrication and biosensing.

  6. Investigation of a cup-shaped ultrasonic transducer operated in the full-wave vibrational mode.

    PubMed

    Xu, Long

    2015-05-01

    Cup-shaped horn has significant applications in ultrasonic machining, such as continuous bonding of plastic sheet or strips. Generally, it is excited by a sandwich piezoelectric transducer and both together constitute a cup-shaped ultrasound transducer (CUT). To provide a concise theoretical model for its engineering applications, the equivalent circuit of the cup-shaped ultrasonic transducer is deduced and the resonance/anti-resonance frequency equations are obtained. Meanwhile, the vibrational characteristics of the cup-shaped ultrasonic transducer have been investigated by using the analytical and numerical methods, and then confirmed by the experiment. The results show that the cup-shaped horn has a distinctive equivalent circuit, and the cup-shaped ultrasonic transducer has a good vibrational performance.

  7. Performance of Porous Tantalum vs. Titanium Cup in Total Hip Arthroplasty: Randomized Trial with Minimum 10-Year Follow-Up.

    PubMed

    Wegrzyn, Julien; Kaufman, Kenton R; Hanssen, Arlen D; Lewallen, David G

    2015-06-01

    Porous tantalum monoblock cups have been proposed to improve survivorship of cementless primary THA. However, there are few direct comparative trials to established implants such as porous-coated titanium cups. 113 patients were randomized into two groups according to the cup: a porous tantalum monoblock cup (TM) or a porous-coated titanium monoblock cup (control). At a mean of 12 years after THA, no implants migrated in both groups. Two TM patients (4%) and 13 control patients (33%) presented with radiolucency around the cup (P<0.001). In the control group, 1 cup (2%) was revised for aseptic loosening. At 12 years post-implantation, porous tantalum monoblock cups demonstrated 100% survivorship, and significantly less radiolucency as compared to porous-coated titanium monoblock cups.

  8. Multiple data sets and modelling choices in a comparative LCA of disposable beverage cups.

    PubMed

    van der Harst, Eugenie; Potting, José; Kroeze, Carolien

    2014-10-01

    This study used multiple data sets and modelling choices in an environmental life cycle assessment (LCA) to compare typical disposable beverage cups made from polystyrene (PS), polylactic acid (PLA; bioplastic) and paper lined with bioplastic (biopaper). Incineration and recycling were considered as waste processing options, and for the PLA and biopaper cup also composting and anaerobic digestion. Multiple data sets and modelling choices were systematically used to calculate average results and the spread in results for each disposable cup in eleven impact categories. The LCA results of all combinations of data sets and modelling choices consistently identify three processes that dominate the environmental impact: (1) production of the cup's basic material (PS, PLA, biopaper), (2) cup manufacturing, and (3) waste processing. The large spread in results for impact categories strongly overlaps among the cups, however, and therefore does not allow a preference for one type of cup material. Comparison of the individual waste treatment options suggests some cautious preferences. The average waste treatment results indicate that recycling is the preferred option for PLA cups, followed by anaerobic digestion and incineration. Recycling is slightly preferred over incineration for the biopaper cups. There is no preferred waste treatment option for the PS cups. Taking into account the spread in waste treatment results for all cups, however, none of these preferences for waste processing options can be justified. The only exception is composting, which is least preferred for both PLA and biopaper cups. Our study illustrates that using multiple data sets and modelling choices can lead to considerable spread in LCA results. This makes comparing products more complex, but the outcomes more robust.

  9. The Cup'ik People of the Western Tundra: A Curriculum.

    ERIC Educational Resources Information Center

    Pingayak, John

    The Cup'ik people are a group of Yup'ik Eskimos who live in southwest Alaska. This curriculum aims to enhance Cup'ik students' interest in their own culture by making that culture a part of their daily activities; to teach students to practice the traditional Cup'ik respect for elders, fellow students, and others in the community; and to teach…

  10. World cup soccer players tend to be born with sun and moon in adjacent zodiacal signs

    PubMed Central

    Verhulst, J

    2000-01-01

    The ecliptic elongation of the moon with respect to the sun does not show uniform distribution on the birth dates of the 704 soccer players selected for the 1998 World Cup. However, a uniform distribution is expected on astronomical grounds. The World Cup players show a very pronounced tendency (p = 0.00001) to be born on days when the sun and moon are in adjacent zodiacal signs. Key Words: soccer; World Cup; astrology; moon PMID:11131239

  11. Design and Construction of a Fast Ion Loss Faraday Cup Array Diagnostic for JET

    SciTech Connect

    D.S. Darrow; S. Bauumel; F.E. Cecil; V. Kiptily; R. Ellis; L. Pedrick; A. Werner

    2004-04-26

    A thin foil Faraday cup array is being built to measure the loss of 3.5 MeV alpha particles and MeV ion cyclotron heating (ICH) tail ions on JET. It will consist of nine detectors spread over five different poloidal locations and three radial positions. They will measure the poloidal distribution and radial scrape off of the losses. The detectors will be comprised of four layers of thin (2.5 micron) Ni foil, giving some resolution of the lost particle energy distribution as different ranges of energies will stop in different layers of the detector. One detector will utilize eight thinner (1.0 micron) foils to obtain a better resolved energy distribution. These detectors will accept particles incident up to 45{sup o} from the normal to the foils.

  12. Slit disk for modified faraday cup diagnostic for determining power density of electron and ion beams

    DOEpatents

    Teruya, Alan T [Livermore, CA; Elmer,; John, W [Danville, CA; Palmer, Todd A [State College, PA

    2011-03-08

    A diagnostic system for characterization of an electron beam or an ion beam includes an electrical conducting disk of refractory material having a circumference, a center, and a Faraday cup assembly positioned to receive the electron beam or ion beam. At least one slit in the disk provides diagnostic characterization of the electron beam or ion beam. The at least one slit is located between the circumference and the center of the disk and includes a radial portion that is in radial alignment with the center and a portion that deviates from radial alignment with the center. The electron beam or ion beam is directed onto the disk and translated to the at least one slit wherein the electron beam or ion beam enters the at least one slit for providing diagnostic characterization of the electron beam or ion beam.

  13. Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China

    PubMed Central

    Liu, Xinwei; Xu, Shuogui; Su, Jiacan; Yu, Baoqing

    2009-01-01

    Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40–50°C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D’Aubigne−Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply. PMID:20012433

  14. The role of biomechanics and engineering in total hip replacement. Why surgeons need technical help.

    PubMed

    Jeffers, Jonathan R T

    2012-12-01

    Implanting the acetabular cup of hard-on-hard bearings, like metal-on-metal or ceramic-on-ceramic, requires considerable surgeon skill to avoid the complications associated with edge loading. Successful cup positioning instruments have been designed in the past by pioneering surgeons, like Peter Ring and Michael Freeman, and these are re-visited in this article. An advantage of these instruments is that they could position the acetabular cup without defining a reference pelvic plane. Computer-assisted cup orientation is able to reduce outliers in cup orientation, but the technology has not been widely adopted. There may be an opportunity to improve the uptake of computer-assisted surgery by incorporating some of the concepts from historically successful manual instruments.

  15. Efficacy of cupping therapy in patients with the fibromyalgia syndrome-a randomised placebo controlled trial

    PubMed Central

    Lauche, Romy; Spitzer, Julia; Schwahn, Barbara; Ostermann, Thomas; Bernardy, Kathrin; Cramer, Holger; Dobos, Gustav; Langhorst, Jost

    2016-01-01

    This study aimed to test the efficacy of cupping therapy to improve symptoms and quality of life in patients diagnosed with the fibromyalgia syndrome. Participants were randomly assigned to cupping therapy, sham or usual care. Cupping was administered five times at twice weekly intervals on the upper and lower back. The primary outcome measure was pain intensity at day 18. Secondary outcomes included functional disability, quality of life, fatigue and sleep quality as well as pressure pain sensitivity, satisfaction and safety at day 18 and 6 months. Altogether 141 patients were included in this study (139 females, 55.8 ± 9.1 years). After 18 days patients reported significant less pain after cupping compared to usual care (difference −12.4; 95% CI: −18.9; −5.9, p < 0.001) but not compared to sham (difference −3.0; 95% CI: −9.9, 3.9, p = 0.396). Further effects were found for quality of life compared to usual care. Patients were mildly satisfied with cupping and sham cupping; and only minor side effects were observed. Despite cupping therapy being more effective than usual care to improve pain intensity and quality of life, effects of cupping therapy were small and comparable to those of a sham treatment, and as such cupping cannot be recommended for fibromyalgia at the current time. PMID:27853272

  16. Two-incision technique for rotational acetabular osteotomy: good outcome in 35 hips.

    PubMed

    Pajarinen, Jarkko; Hirvensalo, Eero

    2003-04-01

    We have developed a 2-incision technique for rotational acetabular osteotomy. This includes both an extraperitoneal and an anterolateral exposure of the pelvic bones allowing an unconstrained approach without dissection of the muscle insertion. 2 plates are used to stabilize the osteotomy and full range motion of the hip is permitted within 2 days of surgery, while weight bearing is restricted for 6 weeks after the operation. We reviewed the complications and technical results in 27 patients (28 hips) after a minimum follow-up of mean 3 (1-5) years. No major surgical complications occurred, but dysfunction of the lateral femoral cutaneous nerve occurred frequently (14 patients). The radiographical correction of the femoral head covering was similar to those in previous reports of rotational osteotomy. The range of hip motion was not affected by the operation. A significant increase in the mean Merle D'Aubigné and Harris Hip scores was observed in a subgroup of 20 patients with a minimum follow-up of 2 years. In conclusion, the method we have used is safe and the early results are satisfactory.

  17. A Reliability-Based Particle Filter for Humanoid Robot Self-Localization in RoboCup Standard Platform League

    PubMed Central

    Sánchez, Eduardo Munera; Alcobendas, Manuel Muñoz; Noguera, Juan Fco. Blanes; Gilabert, Ginés Benet; Simó Ten, José E.

    2013-01-01

    This paper deals with the problem of humanoid robot localization and proposes a new method for position estimation that has been developed for the RoboCup Standard Platform League environment. Firstly, a complete vision system has been implemented in the Nao robot platform that enables the detection of relevant field markers. The detection of field markers provides some estimation of distances for the current robot position. To reduce errors in these distance measurements, extrinsic and intrinsic camera calibration procedures have been developed and described. To validate the localization algorithm, experiments covering many of the typical situations that arise during RoboCup games have been developed: ranging from degradation in position estimation to total loss of position (due to falls, ‘kidnapped robot’, or penalization). The self-localization method developed is based on the classical particle filter algorithm. The main contribution of this work is a new particle selection strategy. Our approach reduces the CPU computing time required for each iteration and so eases the limited resource availability problem that is common in robot platforms such as Nao. The experimental results show the quality of the new algorithm in terms of localization and CPU time consumption. PMID:24193098

  18. The DHL EuroCup: shots on goal.

    PubMed

    Hemp, Paul

    2003-11-01

    Deutsche Post World Net, the German postal monopoly, faced significant challenges as it began the process of integrating three businesses: Deutsche Post Euro Express, its own ground-based parcel delivery service, and two companies it had acquired-DHL, the worldwide express delivery service, and Danzas, a worldwide air and ocean freight company. The cultural differences alone were imposing. For example, DHL was a privately held, entrepreneurial company in which most managers had international experience; Deutsche Post was until recently a state-owned monopoly in which few managers had worked outside their home country. Enter EuroCup. For 20 years, DHL employees had held a soccer tournament to strengthen company culture across national boundaries. Canceled the previous year due to budget constraints, the EuroCup tournament was revived in 2003-in part to help with the postmerger integration. But did the event really help? HBR senior editor Paul Hemp attended EuroCup 2003, joining nearly 2,500 DHL employees--about 600 of them players, the rest cheerleaders and other supporters--in the small Belgian town of Lommel. He set out to answer a number of questions relevant to any company staging an ambitious off-site intended to encourage teamwork and boost morale. How does a company determine whether such a large-scale event, even one that generates goodwill, is worth the investment? Does the team building extend to those back home who don't get to attend? Can intense competition between teams begin to overshadow the spirit of cooperation that such an event is meant to engender? In short, can a soccer tournament help a company achieve its corporate goal of creating a strong common culture?

  19. Faraday cup: absolute dosimetry for ELIMED beam line

    NASA Astrophysics Data System (ADS)

    Leanza, R.; Romano, F.; Scuderi, V.; Amico, A. G.; Cuttone, G.; Larosa, G.; Margarone, D.; Milluzzo, G.; Petringa, G.; Pipek, J.; Schillaci, F.; Cirrone, G. A. P.

    2017-03-01

    The scientific community has shown a growing interest towards multidisciplinary applications of laser-driven beams. In this framework, the ELIMED (ELI-Beamlines MEDical and multidisciplinary applications) beamline will be the first transport beamline dedicated to the medical and multidisciplinary studies with laser-accelerated ion beams. Detectors for dosimetry represent one of key-element of the ELIMED beamline, allowing a dose delivering with good result as required in the clinical applications. In this contribution, a Faraday Cup for absolute dosimetry, designed and realized at INFN-LNS, is described.

  20. Self-eating from an ER-associated cup.

    PubMed

    Simonsen, Anne; Stenmark, Harald

    2008-08-25

    Since the first morphological description of autophagosomes in the early 1960s, two critical questions have been a matter of intense investigation and debate: what is the origin of the autophagosomal membrane and how is it formed? A study by Axe et al. (E.L. Axe, S.A. Walker, M. Manifava, P. Chandra, H.L. Roderick, A. Habermann, G. Griffiths, and N.T. Ktistakis. 2008. J. Cell Biol. 182:685-701) provides evidence that cup-shaped protrusions from the endoplasmic reticulum, named omegasomes, serve as platforms for autophagosome biogenesis in mammalian cells.

  1. Excellent long-term results of the Müller acetabular reinforcement ring in primary total hip arthroplasty

    PubMed Central

    Sirka, Aurimas; Clauss, Martin; Tarasevicius, Sarunas; Wingstrand, Hans; Stucinskas, Justinas; Robertsson, Otto; Emil Ochsner, Peter; Ilchmann, Thomas

    2016-01-01

    Background and purpose — The original Müller acetabular reinforcement ring (ARR) shows favorable medium-term results for acetabular reconstruction in total hip arthroplasty, where it is used when the acetabular bone stock is deficient. However, there are no data regarding long-term survival of the device. We therefore investigated long-term survival and analyzed radiological modes of failure. Patients and methods — Between 1984 and 2002, 321 consecutive primary arthroplasties using an ARR were performed in 291 patients. The mean follow-up time was 11 (0–25) years, and 24 hips were lost to follow-up. For survival analysis, we investigated 321 hips and the end of the follow-up was the date of revision, date of death, or the last patient contact date with implant still in situ. Radiological assessment was performed for 160 hips with a minimum of 10 years of follow-up and with radiographs of sufficient quality. It included evaluation of osteolysis, migration, and loosening. Results — 12 ARR THAs were revised: 1 isolated ARR revision for aseptic loosening, 4 revisions of the ARR and the stem for aseptic loosening, 6 for infection, and 1 for recurrent dislocation. The cumulative revision rate for all components, for any reason, at 20 years was 15% (95% CI: 10–22), while for the ARR only it was 7% (95% CI: 4–12) for any reason and 3.4% (95% CI: 1–9) for aseptic loosening. 21 (13%) of 160 ARR THAs examined had radiological changes: 7 had osteolysis but were not loose, and 14 were radiologically loose but were not painful and not revised. Interpretation — Our data suggest that the long-term survival of the ARR is excellent. PMID:26471881

  2. Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components.

    PubMed

    Takahashi, Yasuhito; Tateiwa, Toshiyuki; Shishido, Takaaki; Masaoka, Toshinori; Kubo, Kosuke; Yamamoto, Kengo

    2016-10-01

    The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs).

  3. Viscosity Measurements of Industrial Alloys Using the Oscillating Cup Technique

    NASA Astrophysics Data System (ADS)

    Banerjee, P.; Overfelt, R. A.

    1999-11-01

    Molten metal processing can be effectively simulated using state-of-the-art computer algorithms, and manufacturers increasingly rely upon these tools to optimize the design of their operations. Reliable thermophysical properties of the solid, solid + liquid, and liquid phases are essential for effective computer simulation. Commercially available instruments can measure many of the required properties of molten metals (e.g., transformation temperatures, thermal conductivity, specific heat, latent heat, and density). However, there are no commercially available instruments to characterize several important thermophysical properties (e.g., emissivity, electrical resistivity, surface tension, and viscosity). Although the literature has numerous examples of measurements of surface tension using the sessile drop and the oscillating drop techniques, literature references are sparse with regard to measurements of emissivity, electrical resistivity, and viscosity. The present paper discusses the development of an oscillating cup viscometer and its application to characterizing the viscosity of fully molten industrial alloys. The theory behind the oscillating cup technique is reviewed, and the design details of the current instrument are discussed. In addition, experimental data of the viscosity of several nickel-based superalloys are presented.

  4. Extended higher cup-product Chern-Simons theories

    NASA Astrophysics Data System (ADS)

    Fiorenza, Domenico; Sati, Hisham; Schreiber, Urs

    2013-12-01

    The proper action functional of (4k+3)-dimensional U(1)-Chern-Simons theory including the instanton sectors has a well known description: it is given on the moduli space of fields by the fiber integration of the cup product square of classes in degree-(2k+2) differential cohomology. We first refine this statement from the moduli space to the full higher smooth moduli stack of fields, to which the higher-order-ghost BRST complex is the infinitesimal approximation. Then we generalize the refined formulation to cup product Chern-Simons theories of nonabelian and higher nonabelian gauge fields, such as the nonabelian String-2-connections appearing in quantum-corrected 11-dimensional supergravity and M-branes. We discuss aspects of the off-shell extended geometric prequantization (in the sense of extended or multi-tiered QFT) of these theories, where there is a prequantum U(1)-k-bundle (equivalently: a U(1)-(k - 1)-bundle gerbe) in each codimension k. Examples we find include moduli stacks for differential T-duality structures as well as the anomaly line bundles of higher electric/magnetic charges, such as the 5-brane charges appearing in heterotic supergravity, appearing as line bundles with connection on the smooth higher moduli stacks of field configurations.

  5. 78 FR 21260 - Safety Zone; Lubbers Cup Regatta; Spring Lake, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    ... SECURITY Coast Guard 33 CFR PART 165 RIN 1625-AA00 Safety Zone; Lubbers Cup Regatta; Spring Lake, MI AGENCY... safety zone on Spring Lake in Spring Lake, Michigan. This safety zone is intended to restrict vessels from a portion of Spring Lake due to the Lubbers Cup Regatta. This temporary safety zone is...

  6. Athletic Departments' Operating Expenses as a Predictor of Their Directors' Cup Standing

    ERIC Educational Resources Information Center

    Magner, Amber

    2014-01-01

    The NACDA Directors' Cup is a competition utilizing an unbiased scoring system that encourages a broad based athletic department as the standard for defining intercollegiate athletic success. Therefore, for NCAA DI athletic administrators the Directors' Cup should be the standard for defining intercollegiate athletic success. The purpose of this…

  7. A level set method for cupping artifact correction in cone-beam CT

    SciTech Connect

    Xie, Shipeng; Li, Haibo; Ge, Qi; Li, Chunming

    2015-08-15

    Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts in CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts.

  8. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization.

    PubMed

    Hu, Jing; Rovey, Joshua L

    2011-07-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a "double-humped" energy distribution.

  9. Sector-based optic cup segmentation with intensity and blood vessel priors.

    PubMed

    Yin, Fengshou; Liu, Jiang; Wong, Damon W K; Tan, Ngan Meng; Cheng, Jun; Cheng, Ching-Yu; Tham, Yih Chung; Wong, Tien Yin

    2012-01-01

    The optic cup segmentation is critical for automated cup-to-disk ratio measurement, and hence computer-aided diagnosis of glaucoma. In this paper, we propose a novel sector-based method for optic cup segmentation. The method comprises two parts: intensity-based cup segmentation with shape constraints and blood vessel-based refinement. The initial estimation of the cup is obtained by applying a statistical deformable model on the vessel free image. At the same time, blood vessels within the optic disk are extracted, after which vessel bendings and vessel boundaries in the nasal side are located. Subsequently, these key points in the blood vessels are used to fine tune the cup. The algorithm is evaluated on 650 fundus images from the ORIGA(-light) database. Experimental results show that the Dice coefficient for the optic cup segmentation can be as high as 0.83, which outperforms other existing methods. The results demonstrate good potential for the proposed method to be used in automated optic cup segmentation and glaucoma diagnosis.

  10. 76 FR 39289 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit... waters immediately prior to, during, and immediately after the Detroit APBA Gold Cup boat race. This.... Basis and Purpose This interim rule will amend the entry found in 33 CFR 100.918, Detroit APBA Gold...

  11. Research on the 2-axis cup-wheel dressing technology of arc-diamond grinding wheel

    NASA Astrophysics Data System (ADS)

    Chang, X. L.; Wu, H. Y.; Peng, Y. F.

    2014-08-01

    The precision dressing of arc-diamond wheel is very hard, expensive and time-consuming because of the super-hard diamond particles and complicated geometrical shape. This paper aims to investigate the cup-wheel dressing technology to realize the high-efficiency regeneration of the arc-diamond wheel. A two-axis cup-wheel dressing technique for precision dressing arc-diamond wheel was suggested and tested. The dressing mechanism of 2-axis cup-wheel was studied. The dressing algorithm and error compensation method were further investigated to improve the dressing precision and efficiency. The experimental results show that the 2-axis cup-wheel dressing technique is valid and applicable to realize the precision dressing of arc-diamond wheel. The machined optical surface condition was apparently improved with the cup-wheel dressed diamond wheel and even became much better when the error compensation algorithm was performed on the arc-diamond wheel.

  12. [Clinical application of moving cupping therapy based on skin reaction observation and syndrome differentiation].

    PubMed

    Deng, Xiao-Lan; Chen, Bo; Chen, Ze-Lin

    2014-12-01

    The diagnostic evidence on clinical diseases and theoretic basis of moving cupping therapy were ex- plored in the paper. By the observation of the local reaction, such as skin appearance and color, the affected location, duration of sickness and nature of disease were judged. Different moving cupping methods were selected for different disorders. It was discovered that the property of syndromes should be recognized by the palpation on skin and muscle in the moving cupping therapy so that the pathogenesis and treating principle could be carefully determined. The moving cupping therapy is the important component of body surface therapy. Skin reaction observation and syndrome differentiation is the essential guidance of the moving cupping therapy.

  13. The incidence of stress fracture following peri-acetabular osteotomy: an under-reported complication.

    PubMed

    Malviya, A; Dandachli, W; Beech, Z; Bankes, M J; Witt, J D

    2015-01-01

    Stress fractures occurring in the pubis and ischium after peri-acetabular osteotomy (PAO) are not well recognised, with a reported incidence of 2% to 3%. The purpose of this study was to analyse the incidence of stress fracture after Bernese PAO under the care of two high-volume surgeons. The study included 359 patients (48 men, 311 women) operated on at a mean age of 31.1 years (15 to 56), with a mean follow-up of 26 months (6 to 64). Complete follow-up radiographs were available for 348 patients, 64 of whom (18.4%) developed a stress fracture of the inferior pubic ramus, which was noted at a mean of 9.1 weeks (5 to 55) after surgery. Most (58; 91%) healed. In 40 of the patients with a stress fracture (62.5%), pubic nonunion also occurred. Those with a stress fracture were significantly older (mean 33.9 years (16 to 50) vs 30.5 years (15 to 56), p = 0.002) and had significantly more mean pre-operative deformity: mean centre-edge angle (9.8° (-9.5 to 35) vs 12.4° (-33 to 28), p = 0.04) and mean Tönnis angle (22.8° (0 to 45) vs 18.7° (-2 to 38), p < 0.001). The pubic nonunion rate was significantly higher in those with a stress fracture (62.5% vs 7%, p < 0.001), with regression analysis revealing that these patients had 11.8 times higher risk than those without nonunion.

  14. Germline genetics of cancer of unknown primary (CUP) and its specific subtypes

    PubMed Central

    Hemminki, Kari; Chen, Bowang; Kumar, Abhishek; Melander, Olle; Manjer, Jonas; Hallmans, Göran; Pettersson-Kymmer, Ulrika; Ohlsson, Claes; Folprecht, Gunnar; Löffler, Harald; Krämer, Alwin; Försti, Asta

    2016-01-01

    Cancer of unknown primary site (CUP) is a fatal cancer diagnosed through metastases at various organs. Little is known about germline genetics of CUP which appears worth of a search in view of reported familial associations in CUP. In the present study, samples from CUP patients were identified from 2 Swedish biobanks and a German clinical trial, totaling 578 CUP patients and 7628 regionally matched controls. Diagnostic data specified the organ where metastases were diagnosed. We carried out a genome-wide association study on CUP cases and controls. In the whole sample set, 6 loci reached an allelic p-value in the range of 10−7 and were supported by data from the three centers. Three associations were located next to non-coding RNA genes. rs2660852 flanked 5′UTR of LTA4H (leukotriene A4 hydrolase), rs477145 was intronic to TIAM1 (T-cell lymphoma invasion and metastases) and rs2835931 was intronic to KCNJ6 (potassium channel, inwardly rectifying subfamily J, member 6). In analysis of subgroups of CUP patients (smokers, non-smokers and CUP with liver metastases) genome-wide significant associations were noted. For patients with liver metastases associations on chromosome 6 and 11, the latter including a cluster of genes DHCR7 and NADSYN1, encoding key enzymes in cholesterol and NAD synthesis, and KRTAP5-7, encoding a keratin associated protein. This first GWAS on CUP provide preliminary evidence that germline genes relating to inflammation (LTA4H), metastatic promotion (TIAM1) in association with lipid metabolic disturbance (chromosome 11 cluster) may contribute to the risk of CUP. PMID:26959888

  15. Theoretical Implications of Periacetabular Osteotomy in Various Dysplastic Acetabular Cartilage Defects as Determined by Finite Element Analysis

    PubMed Central

    Xu, Meng; Qu, Wenrui; Wang, Yanbing; Zhong, Lei; Zhu, Zhe; Li, Wei; Zhao, Xin; Wang, Jincheng; Sun, Yu

    2016-01-01

    Background Different extents and locations of acetabular cartilage defect have been supposed to be a major cause of undesirable outcomes of periacetabular osteotomy (PAO) in patients with developmental dysplasia of the hip (DDH). This study aimed to verify whether different locations of cartilage deficiency affect the biomechanical environment in a three-dimensional model utilizing finite element analysis (FEA). Material/Methods We developed 3 DDH models – DDH-1 (normal shape), DDH-2 (superior defect), and DDH-3 (anterosuperior defect) – by deforming from a normal hip model. We also developed 3 PAO models – PAO-1, PAO-2, and PAO-3 – through rotating osteotomized fragments. Results The maximum von Mises stress in the normal hip was 13.06 MPa. In the DDH-1 model, the maximum value on the load-bearing area decreased from 15.49 MPa pre-PAO to 14.28 MPa post-PAO, while stresses in the DDH-2 and DDH-3 models were higher than in the DDH-1 model, both pre-PAO and post-PAO (30.46 MPa to 26.04 MPa for DDH-2; 33.89 MPa to 27.48 MPa for DDH-3). Conclusions This study shows that, both pre- and post-PAO, different types of cartilage deficiency affect the biomechanical environment. Furthermore, in dysplastic hips, obtaining accurate three-dimensional information about the acetabular cartilage can contribute substantially to PAO decision making. PMID:28017958

  16. Hip flexor muscle size, strength and recruitment pattern in patients with acetabular labral tears compared to healthy controls.

    PubMed

    Mendis, M Dilani; Wilson, Stephen J; Hayes, David A; Watts, Mark C; Hides, Julie A

    2014-10-01

    Acetabular labral tears are a source of hip pain and are considered to be a precursor to hip osteoarthritis. Hip flexor muscles contribute to hip joint stability and function but it is unknown if their size and function is altered in the presence of labral pathology. This study aimed to investigate hip flexor muscle size, strength and recruitment pattern in patients with hip labral pathology compared to control subjects. 12 subjects diagnosed with an unilateral acetabular labral tear were compared to 12 control subjects matched for age and gender. All subjects underwent magnetic resonance imaging (MRI) of their lumbo-pelvic region. Average muscle cross-sectional area (CSA) of the iliacus, psoas, iliopsoas, sartorius, tensor fascia latae and rectus femoris muscles were measured. Hip flexion strength was measured by an externally fixed dynamometer. Individual muscle recruitment pattern during a resisted hip flexion exercise task was measured by muscle functional MRI. Hip flexor muscle strength was found to be decreased in patients with labral pathology compared to control subjects (p < 0.01). No difference between groups or sides was found for hip flexor muscle size (all p > 0.17) and recruitment pattern (all p > 0.53). Decreased hip flexor muscle strength may affect physical function in patients with hip labral pathology by contributing to altered gait patterns and functional tasks. Clinical rehabilitation of these patients may need to include strengthening exercises for the hip flexor muscles.

  17. Highly Cross-linked Polyethylene Liner Dissociation from a Cement-less Modular Acetabular Shell: Two Case Reports

    PubMed Central

    Kawano, Shunsuke; Sonohata, Motoki; Kitajima, Masaru; Mawatari, Masaaki

    2016-01-01

    Liner dissociation of polyethylene from a cementless acetabular socket following total hip arthroplasty (THA) is a rare complication. Cross-linked polyethylene liner dissociation from AMS-HA shell (KYOCERA Med, Osaka, Japan) occurred in 2 out of the 4153 (0.04%) cases approximately 10 years after undergoing surgery at our institute. First case was an 80-year-old female who underwent right THA along with subtrochanteric femoral shortening osteotomy due to complete dislocation hip, and second case was a 72-year-old male, who underwent right THA due to coxarthrosis. A 26 mm femoral head and CPE liner were used in both cases and the inclination degree of the acetabular socket was within 50°.There was no implant loosening in both cases. There was partial damage in the elevated rim on the alternative side and scratches on the back side in the both extracted CPE liner. It was surmised that liner dissociation was caused due to a problem in the liner fixing format of the push in type of the present model. PMID:28217197

  18. Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: a report of two cases.

    PubMed

    Teeter, Matthew G; Naudie, Douglas D R; Charron, Kory D; Holdsworth, David W

    2010-08-01

    There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved between four to five years after implantation. The two XLPE acetabular liners (Reflection, Smith and Nephew Inc., Memphis, TN) were retrieved from patients undergoing their second revision surgery, at 4.90 and 4.07 years. The retrieved liners and a new, non-implanted, unworn liner of the same size were scanned using micro-computed tomography (micro-CT). Articular surface deviation maps were created by comparing the retrievals to the unworn liner, based on the liner geometry obtained from micro-CT. The linear penetration rates were found to be 0.018 and 0.008 mm/year. Localized scratches and pits with deviations greater than 0.205 mm were also found on the articular surfaces of both liners. The XLPE liners retrieved from the two cases demonstrated low linear penetration rates. Regions with greater focal deviations were also apparent, likely due to third-body wear. The results are consistent with previously published clinical follow-ups of other XLPE liners.

  19. Cup waveguide antenna with integrated polarizer and OMT

    NASA Technical Reports Server (NTRS)

    Acosta, Roberto J. (Inventor); Kory, Carol (Inventor); Lambert, Kevin M. (Inventor)

    2011-01-01

    A cup waveguide antenna with integrated polarizer and OMT for simultaneously communicating left and right hand circularly polarized electromagnetic waves is adjustable to obtain efficient propagation and reception of electromagnetic waves. The antenna includes a circular waveguide having an orthomode transducer utilizing first and second pins longitudinally spaced apart and oriented orthogonally with respect to each other. Six radially-oriented adjustable polarizer screws extend from the exterior to the interior of the waveguide. A septum intermediate the first and second pins is aligned with the first pin. Adjustment of the polarizer screws enables maximized propagation of and/or response to left hand circularly polarized electromagnetic waves by the first pin while simultaneously enabling maximized propagation of and/or response to right hand circularly polarized electromagnetic waves by the second pin.

  20. CUP-1 Is a Novel Protein Involved in Dietary Cholesterol Uptake in Caenorhabditis elegans

    PubMed Central

    Valdes, Victor J.; Athie, Alejandro; Salinas, Laura S.; Navarro, Rosa E.; Vaca, Luis

    2012-01-01

    Sterols transport and distribution are essential processes in all multicellular organisms. Survival of the nematode Caenorhabditis elegans depends on dietary absorption of sterols present in the environment. However the general mechanisms associated to sterol uptake in nematodes are poorly understood. In the present work we provide evidence showing that a previously uncharacterized transmembrane protein, designated Cholesterol Uptake Protein-1 (CUP-1), is involved in dietary cholesterol uptake in C. elegans. Animals lacking CUP-1 showed hypersensitivity to cholesterol limitation and were unable to uptake cholesterol. A CUP-1-GFP fusion protein colocalized with cholesterol-rich vesicles, endosomes and lysosomes as well as the plasma membrane. Additionally, by FRET imaging, a direct interaction was found between the cholesterol analog DHE and the transmembrane “cholesterol recognition/interaction amino acid consensus” (CRAC) motif present in C. elegans CUP-1. In-silico analysis identified two mammalian homologues of CUP-1. Most interestingly, CRAC motifs are conserved in mammalian CUP-1 homologous. Our results suggest a role of CUP-1 in cholesterol uptake in C. elegans and open up the possibility for the existence of a new class of proteins involved in sterol absorption in mammals. PMID:22479487

  1. Prediction of specialty coffee cup quality based on near infrared spectra of green coffee beans.

    PubMed

    Tolessa, Kassaye; Rademaker, Michael; De Baets, Bernard; Boeckx, Pascal

    2016-04-01

    The growing global demand for specialty coffee increases the need for improved coffee quality assessment methods. Green bean coffee quality analysis is usually carried out by physical (e.g. black beans, immature beans) and cup quality (e.g. acidity, flavour) evaluation. However, these evaluation methods are subjective, costly, time consuming, require sample preparation and may end up in poor grading systems. This calls for the development of a rapid, low-cost, reliable and reproducible analytical method to evaluate coffee quality attributes and eventually chemical compounds of interest (e.g. chlorogenic acid) in coffee beans. The aim of this study was to develop a model able to predict coffee cup quality based on NIR spectra of green coffee beans. NIR spectra of 86 samples of green Arabica beans of varying quality were analysed. Partial least squares (PLS) regression method was used to develop a model correlating spectral data to cupping score data (cup quality). The selected PLS model had a good predictive power for total specialty cup quality and its individual quality attributes (overall cup preference, acidity, body and aftertaste) showing a high correlation coefficient with r-values of 90, 90,78, 72 and 72, respectively, between measured and predicted cupping scores for 20 out of 86 samples. The corresponding root mean square error of prediction (RMSEP) was 1.04, 0.22, 0.27, 0.24 and 0.27 for total specialty cup quality, overall cup preference, acidity, body and aftertaste, respectively. The results obtained suggest that NIR spectra of green coffee beans are a promising tool for fast and accurate prediction of coffee quality and for classifying green coffee beans into different specialty grades. However, the model should be further tested for coffee samples from different regions in Ethiopia and test if one generic or region-specific model should be developed.

  2. Differential effects of tamoxifen and anastrozole on optic cup size in breast cancer survivors

    PubMed Central

    Toomey, Maureen D.; Falardeau, Julie; Samples, John R.; Vetto, John T.

    2007-01-01

    Introduction The main purpose of this study was to determine whether the optic cups of tamoxifen users and anastrozole users differ in size, with the cups of the tamoxifen users being smaller. Methods Optic nerve head (ONH) topography was measured using a commercially available, confocal scanning laser ophthalmoscope for three populations of amenorrheic women ages 40–69 years: subjects using (1) tamoxifen (20 mg/day) or (2) anastrozole (1 mg/day) for ≤ 2 years as adjuvant therapy after successful primary treatment for breast cancer, and (3) control subjects with no breast cancer histories and not using any hormonal medication. All subjects had excellent visual acuity and healthy eyes, based on conventional photographic assessment. Results The cup volumes of the tamoxifen users were shown to be significantly smaller than the cup volumes of the anastrozole users, which were indistinguishable from normal. Because the cup volumes of the tamoxifen users decreased markedly with age at about 50 years and because anastrozole is indicated only for post-menopausal women, comparisons were reassessed for subjects older than 50 years. For these subjects, the cup volumes of the tamoxifen users averaged less than half of the volumes for each of the other two subject groups, and significant between-group differences existed in both the lateral (cup area) and axial (cup depth) directions. In contrast, any between-group differences at the ONH margin were small and not significant. Conclusions The results of this study suggest that the ONH be assessed biomorphometrically for tamoxifen users reporting visual change that cannot be attributed to non-tamoxifen causes. The ability of modern intraocular imaging techniques to reveal anatomic change on the order of tens of microns may be useful for assessing tamoxifen-induced effects occurring simultaneously elsewhere in the brain, particularly since the presence of small cups is consistent with the possibility of tamoxifen

  3. Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement.

    PubMed

    Liu, Feng; Williams, Sophie; Jin, Zhongmin; Fisher, John

    2013-11-01

    Head contact on the rim of the cup causes stress concentration and consequently increased wear. The head contact on the rim of the cup may in addition cause an offset load and torque on the cup. The head-rim contact resulting from microseparation or subluxation has been investigated. An analytical model has been developed to calculate the offset loading and resultant torque on the cup as a function of the translational displacement of the head under simplified loading condition of the hip joint at heel strike during a walking cycle. The magnitude of the torque on the cup was found to increase with the increasing translational displacement, larger diameter heads, eccentric cups, and the coefficient of friction of the contact. The effects of cup inclination, cup rim radius, and cup coverage angle on the magnitude of the torque were found to be relatively small with a maximum variation in the torque magnitude being lower than 20%. This study has shown an increased torque due to the head loading on the rim of the cup, and this may contribute to the incidence of cup loosening. Particularly, metal-on-metal hip joints with larger head diameters may produce the highest offset loading torque.

  4. Incorporating Yup'ik and Cup'ik Eskimo traditions into behavioral health treatment.

    PubMed

    Mills, Phoebe A

    2003-01-01

    The Yup'ik and Cup'ik Eskimo of Southwest Alaska have developed programs to provide healing from historical trauma. The Village Sobriety Project, a Center for Substance Abuse Treatment-funded project administered by the Yukon-Kuskokwim Health Corporation from 1999 to 2002, is an effort to incorporate the local Yup'ik and Cup'ik peoples' ways into treatment services for mental health and substance abuse. Activities such as tundra walks and time with elders are supported in treatment, and Medicaid reimbursement was successfully obtained for such activities. Documentation of treatment showed that it incorporated cultural elements of the Yup'ik and Cup'ik people.

  5. Operational experience using the novel FixCup collecting main valve

    SciTech Connect

    Giertz, J.; Huhn, F.; Spitz, J.

    1996-12-31

    On the occasion of the 1995 AIME conference the new PROven (Pressure Regulated Oven) process to control the pressure in coke ovens individually was introduced. This process was made feasible with a new collecting main valve, termed FixCup, with the aid of this valve a variable flow resistance to the raw gas discharge can be realized using a water immersion system. However, just the application of the FixCup system alone--without any pressure regulation--is very advantageous and cost saving. Thyssen has equipped 30 ovens with the new valve. The special constructive features as well as the operational experience using the FixCup valve are treated.

  6. Formation and atomic structure of boron nitride nanotubes with a cup-stacked structure

    NASA Astrophysics Data System (ADS)

    Oku, Takeo; Koi, Naruhiro; Suganuma, Katsuaki; Belosludov, Rodion V.; Kawazoe, Yoshiyuki

    2007-08-01

    Boron nitride (BN) nanotubes were synthesized by annealing Fe 4N/B powder at 1000 ∘C for 1 h in a nitrogen gas atmosphere, and large amounts of BN nanotubes with a cup-stacked structure were obtained after a purification process. The atomic structures of the cup-stacked BN nanotubes were investigated by high-resolution electron microscopy as well as molecular mechanics calculations, and compared with double walled BN nanotubes. The present results indicate that the cup-stacked structure with a cone angle of 20 ∘ is more stable than the structure with an angle of 38 ∘ and ordinary nanotube structures.

  7. Influence of participation in a cup-stacking unit on timing tasks.

    PubMed

    Hart, Melanie A; Smith, Lori A; DeChant, Ann

    2005-12-01

    Cup stacking is a relatively new activity which has been promoted at conferences for physical educators as having many direct and indirect benefits, such as improved quickness. This study examined the influence of a cup-stacking instructional unit on reaction and anticipation times of 69 children in Grades 2 and 4. Within each grade participants were assigned to an experimental or a control group. The former received a 3-wk. instructional unit following the lesson plans provided by the promoters of cup stacking. The control groups received a standard physical education curriculum. Analysis indicated no significant differences in reaction and anticipation times between the groups before and after practicing the instructional unit.

  8. Modified Stoppa Approach versus Ilioinguinal Approach for Anterior Acetabular Fractures; A Systematic Review and Meta-Analysis

    PubMed Central

    Meena, Sanjay; Sharma, Pankaj Kumar; Mittal, Samarth; Sharma, Jyoti; Chowdhury, Buddhadev

    2017-01-01

    Introduction: Modified Stoppa approach was introduced as an alternative to ilioinguinal approach for management of anterior fractures of acetabulum in order to reduce complications of the latter. However, the efficacy of either approach over other is not well established. The aim of this meta-analysis is to compare the efficacy of modified stoppa and ilioinguinal approach in the management of acetabular fractures in terms of a) quality of reduction achieved b) complication rates c) functional outcomes d) operative time e) intra-operative blood loss. Methods: Databases of PubMed, EMBASE and Cochrane registry of controlled trials were taken into consideration for studies on modified Stoppa approach versus Ilioinguinal approach group for the treatment of anterior acetabular fractures. Dichotomous variables were presented as risk ratios (RRs) /Odds Ratio (OR) with 95% confidence intervals (CIs), and continuous data was measured as mean differences, with 95% CIs. Result: Four studies involving 375 patients were included in this meta-analysis. Out of those 375 patients, 192 were managed with ilioinguinal approach and 183 were managed with modified Stoppa approach. Anatomical reduction was significantly higher in Stoppa group (p=0.052, RR=1. 19 (1.02, 1.37), p=0. 90, I2=0%). The complication rate was significantly higher in the Ilioinguinal approach as compared with the Stoppa approach (p=0.01, RR 0.63 (0.44 to 0.91), p=0.73 (I2= 0%). The operative time was significantly shorter with modified Stoppa approach (MD = -48.79 (-80.29 to -17.30), p=0.002). No significant differences were found between the two groups in terms of their functional outcomes (p=0.63, RR 0.96 (-0.80 to 1.15), p=0. 56, I2=0%) and blood loss (MD= -212.89 (-476.27 to 50.49) p=0. 06, I2=71%). Conclusion: Anterior acetabular fractures, if operated with the modified Stoppa approach were found to have better reduction and lower complication rates with less operative time, when compared to ilioinguinal

  9. Corking Nitrogen-Doped Carbon Nanotube Cups with Gold Nanoparticles for Biodegradable Drug Delivery Applications.

    PubMed

    Burkert, Seth C; Star, Alexander

    2015-12-02

    Carbon nanomaterials have been proposed as effective drug delivery devices; however their perceived biopersistence and toxicological profile may hinder their applications in medical therapeutics. Nitrogen doping of carbon nanotubes results in a unique "stacked-cup" structure, with cups held together through van der Waals forces. Disrupting these weak interactions yields individual and short-stacked nanocups that can subsequently be corked with gold nanoparticles, resulting in sealed containers for delivery of cargo. Peroxidase-catalyzed reactions can effectively uncork these containers, followed by complete degradation of the graphitic capsule, resulting in effective release of therapeutic cargo while minimizing harmful side effects. The protocols reported herein describe the synthesis of stacked nitrogen-doped carbon nanotube cups followed by effective separation into individual cups and gold nanoparticle cork formation resulting in loaded and sealed containers.

  10. Convex hull based neuro-retinal optic cup ellipse optimization in glaucoma diagnosis.

    PubMed

    Zhang, Zhuo; Liu, Jiang; Cherian, Neetu Sara; Sun, Ying; Lim, Joo Hwee; Wong, Wing Kee; Tan, Ngan Meng; Lu, Shijian; Li, Huiqi; Wong, Tien Ying

    2009-01-01

    Glaucoma is the second leading cause of blindness. Glaucoma can be diagnosed through measurement of neuro-retinal optic cup-to-disc ratio (CDR). Automatic calculation of optic cup boundary is challenging due to the interweavement of blood vessels with the surrounding tissues around the cup. A Convex Hull based Neuro-Retinal Optic Cup Ellipse Optimization algorithm improves the accuracy of the boundary estimation. The algorithm's effectiveness is demonstrated on 70 clinical patient's data set collected from Singapore Eye Research Institute. The root mean squared error of the new algorithm is 43% better than the ARGALI system which is the state-of-the-art. This further leads to a large clinical evaluation of the algorithm involving 15 thousand patients from Australia and Singapore.

  11. Forecasting a winner for Malaysian Cup 2013 using soccer simulation model

    NASA Astrophysics Data System (ADS)

    Yusof, Muhammad Mat; Fauzee, Mohd Soffian Omar; Latif, Rozita Abdul

    2014-07-01

    This paper investigates through soccer simulation the calculation of the probability for each team winning Malaysia Cup 2013. Our methodology used here is we predict the outcomes of individual matches and then we simulate the Malaysia Cup 2013 tournament 5000 times. As match outcomes are always a matter of uncertainty, statistical model, in particular a double Poisson model is used to predict the number of goals scored and conceded for each team. Maximum likelihood estimation is use to measure the attacking strength and defensive weakness for each team. Based on our simulation result, LionXII has a higher probability in becoming the winner, followed by Selangor, ATM, JDT and Kelantan. Meanwhile, T-Team, Negeri Sembilan and Felda United have lower probabilities to win Malaysia Cup 2013. In summary, we find that the probability for each team becominga winner is small, indicating that the level of competitive balance in Malaysia Cup 2013 is quite high.

  12. Mechanistic Based DEM Simulation of Particle Attrition in a Jet Cup

    SciTech Connect

    Xu, Wei; DeCroix, David; Sun, Xin

    2014-02-01

    The attrition of particles is a major industrial concern in many fluidization systems as it can have undesired effects on the product quality and on the reliable operation of process equipment. Therefore, to accomodate the screening and selection of catalysts for a specific process in fluidized beds, risers, or cyclone applications, their attrition propensity is usually estimated through jet cup attrition testing, where the test material is subjected to high gas velocities in a jet cup. However, this method is far from perfect despite its popularity, largely due to its inconsistency in different testing set-ups. In order to better understand the jet cup testing results as well as their sensitivity to different operating conditions, a coupled computational fluid dynamic (CFD) - discrete element method (DEM) model has been developed in the current study to investigate the particle attrition in a jet cup and its dependence on various factors, e.g. jet velocity, initial particle size, particle density, and apparatus geometry.

  13. Optic disc and cup segmentation from color fundus photograph using graph cut with priors.

    PubMed

    Zheng, Yuanjie; Stambolian, Dwight; O'Brien, Joan; Gee, James C

    2013-01-01

    For automatic segmentation of optic disc and cup from color fundus photograph, we describe a fairly general energy function that can naturally fit into a global optimization framework with graph cut. Distinguished from most previous work, our energy function includes priors on the shape & location of disc & cup, the rim thickness and the geometric interaction of "disc contains cup". These priors together with the effective optimization of graph cut enable our algorithm to generate reliable and robust solutions. Our approach is able to outperform several state-of-the-art segmentation methods, as shown by a set of experimental comparisons with manual delineations and a series of results of correlations with the assessments of a merchant-provided software from Optical Coherence Tomography (OCT) regarding several cup and disc parameters.

  14. FIFA World Cup 2006 in Germany: enhanced surveillance improved timeliness and detection.

    PubMed

    Williams, C J; Schenkel, K; Eckmanns, T; Altmann, D; Krause, G

    2009-04-01

    Enhanced surveillance for infectious disease events, with accelerated routine reporting and daily supplementary reports, was undertaken during the 2006 FIFA World Cup in Germany. We evaluated the surveillance outputs, reporting intervals and detection of World Cup-relevant events for the enhanced system. Outbreak numbers for measles, Norovirus and Campylobacter were significantly higher than in previous years, but all increases were explained by prior trends. The median interval (disease onset to receipt at national centre) fell from 17 days in 2005 to 12 days in 2006. Detection of World Cup-relevant events was 44% (8/18) in the routine system and 77% (14/18) in supplementary reports. We did not identify any significant effect on infectious disease epidemiology relating to the FIFA 2006 World Cup. Daily reporting improved timeliness, and supplementary reporting improved relevant event detection. Enhancing existing systems, without the addition of syndromic surveillance, can be an effective approach to mass-event surveillance.

  15. Region-based multi-step optic disk and cup segmentation from color fundus image

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Lock, Jane; Manresa, Javier Moreno; Vignarajan, Janardhan; Tay-Kearney, Mei-Ling; Kanagasingam, Yogesan

    2013-02-01

    Retinal optic cup-disk-ratio (CDR) is a one of important indicators of glaucomatous neuropathy. In this paper, we propose a novel multi-step 4-quadrant thresholding method for optic disk segmentation and a multi-step temporal-nasal segmenting method for optic cup segmentation based on blood vessel inpainted HSL lightness images and green images. The performance of the proposed methods was evaluated on a group of color fundus images and compared with the manual outlining results from two experts. Dice scores of detected disk and cup regions between the auto and manual results were computed and compared. Vertical CDRs were also compared among the three results. The preliminary experiment has demonstrated the robustness of the method for automatic optic disk and cup segmentation and its potential value for clinical application.

  16. Numerical Study of Two-Phase Flow Field in a Simplified Swirl Cup Combustor (Preprint)

    DTIC Science & Technology

    2007-09-24

    Article 3 . DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Numerical Study of Two-Phase Flow Field in a Simplified Swirl Cup...swirl provides a recirculation zone which enhances mixing and flame stability. Some high-performance aircraft engines such as in GE/SNECMA CFM56 ...downstream of a GE/SNECMA CFM56 engine combustor swirl cup in which the primary and secondary swirlers provide co-axial, counter-swirling airstreams

  17. Effect of Cup Length on Film Profiles in Gas-Centered Swirl-Coaxial Injectors

    DTIC Science & Technology

    2009-12-01

    cup. If the liquid film is not completely broken up within the cup then a secondary, hollow , outer cone will form. This cone contains many droplets...is difficult to measure and costly three-dimensional CFD simulations would be needed to accurately model it. Its effect on atomization/design...This difficulty was recognized early in the US development of GCSC injectors and models specific to GCSC injectors were sought. 2 Further

  18. Coming into focus: the role of extracellular matrix in vertebrate optic cup morphogenesis.

    PubMed

    Kwan, Kristen M

    2014-10-01

    The vertebrate eye acquires its basic form during the process of optic cup morphogenesis, during which the optic vesicle emerges from the brain neuroepithelium and, through a series of cell and tissue movements, transforms itself into the multilayered optic cup, containing neural retina (comprised of retinal progenitors), retinal pigmented epithelium, and the lens, which is derived from the overlying ectoderm. While great strides have been made to understand the developmental signals controlling specification, patterning, and differentiation of the optic cup, only in recent years have the cellular and molecular bases of optic cup morphogenesis begun to be unraveled. One critical component of the morphogenetic process is the extracellular matrix: the complex, glycoprotein-rich layer that surrounds the optic vesicle and lens. Though the extracellular matrix has long been visualized by classical histological techniques and postulated to play various roles in optic cup development, its functional role was uncertain. This is now beginning to change, as live imaging techniques, quantitative image analyses, molecular genetics and in vitro models yield new insights into the process of optic cup morphogenesis and the specific influences of particular extracellular matrix components and their associated signaling pathways.

  19. dlx and sp6-9 Control optic cup regeneration in a prototypic eye.

    PubMed

    Lapan, Sylvain W; Reddien, Peter W

    2011-08-01

    Optic cups are a structural feature of diverse eyes, from simple pit eyes to camera eyes of vertebrates and cephalopods. We used the planarian prototypic eye as a model to study the genetic control of optic cup formation and regeneration. We identified two genes encoding transcription factors, sp6-9 and dlx, that were expressed in the eye specifically in the optic cup and not the photoreceptor neurons. RNAi of these genes prevented formation of visible optic cups during regeneration. Planarian regeneration requires an adult proliferative cell population with stem cell-like properties called the neoblasts. We found that optic cup formation occurred only after migration of progressively differentiating progenitor cells from the neoblast population. The eye regeneration defect caused by dlx and sp6-9 RNAi can be explained by a failure to generate these early optic cup progenitors. Dlx and Sp6-9 genes function as a module during the development of diverse animal appendages, including vertebrate and insect limbs. Our work reveals a novel function for this gene pair in the development of a fundamental eye component, and it utilizes these genes to demonstrate a mechanism for total organ regeneration in which extensive cell movement separates new cell specification from organ morphogenesis.

  20. Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images

    NASA Astrophysics Data System (ADS)

    Hatanaka, Yuji; Noudo, Atsushi; Muramatsu, Chisako; Sawada, Akira; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2010-03-01

    Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. First, the blood vessels were erased from the image and then the edge of optic disc was then detected by use of a canny edge detection filter. Twenty profiles were then obtained around the center of the optic disc in the vertical direction on blue channel of the color image, and the profile was smoothed by averaging these profiles. After that, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method. These results indicated that this method can be useful for the analysis of the optic disc in glaucoma examinations.

  1. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    PubMed Central

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  2. [Development of the ceramic sandwich cup used for the hip joint prosthesis.].

    PubMed

    Konvicková, S; Cech, O

    1995-01-01

    The abrasion of the polyethylene seems to be the most important factor participating on the endoprosthesis loosening. From this reason, the ceramics (AI2O3) was introduced for the both parts of the prosthesis, i. e. the head and the cup. It appears that the friction resistance is an important factor for the comparison of the hitherto applied endoprosthesis designs with the new developed type. The frictional resistance in the hip joint total prosthesis was measured by means of a testing device which allowed a swinging motion of the ceramic ball in the tested cup in the range of +/-25 degrees . This measurement was carried out at the loading levels being 0; 500; 1000; 1500 and 2000 N. For the comparison of the frictional resistance of single measured couples "cup-head", the energy consumed was ascertained which was necessary for including a swinging motion over the time interval of 35 sec. Ceramic cups manufactured by a. s. DIAS Turnov were used for the measurement. Altogether eight couples "ceramics-ceramics" having the diameter differences ranging from 0,022 mm to 0,137 mm and one friction couple "polyethylene cup-ceramics ball" were measured. The research of influence of different lubricants was also done. Key words: sandwich cup, total prosthesis, ceramics--ceramics, bioceramics, frictional resistance.

  3. TNSA Heavy Ion Measurements using the Time-Resolved Tandem Faraday Cup

    NASA Astrophysics Data System (ADS)

    Ginnane, M. K.; Kousar, B.; Slish, J.; Palmisano, K.; Mandanas, S.; Padalino, S. J.; Sangster, T. C.; Regan, S.; Mileham, C.; Stoeckl, C.

    2016-10-01

    The MTW Laser at LLE utilizes an ultra-intense laser to produce high-energy heavy ion pulses through Target Normal Sheath Acceleration (TNSA). Using the Time-Resolved Tandem Faraday Cup (TRTF) the total number of heavy ions produced by TNSA can be determined, which is needed for stellar nuclear reaction cross section measurements. TNSA heavy ions stop within the thin walled front cup, while light ions pass through it and deposit their remaining charge in the back cup. A two channel storage scope measures voltages produced by the beam currents collected in the cups, respectively. The charge state fraction of plasma ions is modified by passing the heavy ions through a charge-exchange foil at the TRTF entrance. While passing through the foil, ions equilibrate to known charge states based on their velocities. Using time of flight, the total heavy ion current can be normalized to the correct charge state fraction. A pair of dipole magnets deflect relativistic TNSA electrons from the cup's entrance. They also prevent secondary electrons from escaping the front and back cups. Funded in part by a LLE contract through the DOE.

  4. Acetabular Prosthetic Protrusio after Bipolar Hemi-Arthroplasty of the Hip: Case Report and Review of the literature

    PubMed Central

    Lim, Jason BT; Ang, Chia Liang; Pang, Hee Nee

    2016-01-01

    Introduction: Bipolar hemi-arthroplasty of the hip is a commonly performed procedure in elderly patients with intra-capsular fracture of the neck of the femur with good short-term results for pain relief, return to activity and morbidity. The incidence of intra-pelvic prosthesis migration or protrusion is rare and one of the inciting factors is chronic low-grade sepsis. Acetabular prosthesis protrusion poses a difficult and challenging surgical problem due to surrounding neurovascular structures. Case Presentation: We present a case report of 60-year-old Chinese female suffering from chronic sepsis of the hip joint causing acetabular prosthetic protrusion with a concomitant peri-prosthetic femoral shaft fracture secondary to a fall, 5 years post index surgery of bipolar hemiarthroplasty for an intra-capsular neck of femur fracture. This patient subsequently underwent a two-stage revision total hip arthroplasty. We aim to discuss the diagnostic approach and surgical management of this complex case of infected protruded bipolar hip hemi-arthroplasty. Conclusion: We highlight three recommendations from this clinical experience. Firstly, there should be a high index of suspicion for chronic infection in protruded prostheses following low energy trauma. Secondly, pre-operative planning for infected protruded prosthetic hips is essential, including arteriogram and a two-staged procedure to tackle possible soft tissue complications. Thirdly, the combined use of serological markers, fluid aspiration as well as intra-operative frozen section is important in the management of PJI and to confirm bacterial eradication before re-implantation. PMID:28116262

  5. The RoboCup Mixed Reality League - A Case Study

    NASA Astrophysics Data System (ADS)

    Gerndt, Reinhard; Bohnen, Matthias; da Silva Guerra, Rodrigo; Asada, Minoru

    In typical mixed reality systems there is only a one-way interaction from real to virtual. A human user or the physics of a real object may influence the behavior of virtual objects, but real objects usually cannot be influenced by the virtual world. By introducing real robots into the mixed reality system, we allow a true two-way interaction between virtual and real worlds. Our system has been used since 2007 to implement the RoboCup mixed reality soccer games and other applications for research and edutainment. Our framework system is freely programmable to generate any virtual environment, which may then be further supplemented with virtual and real objects. The system allows for control of any real object based on differential drive robots. The robots may be adapted for different applications, e.g., with markers for identification or with covers to change shape and appearance. They may also be “equipped” with virtual tools. In this chapter we present the hardware and software architecture of our system and some applications. The authors believe this can be seen as a first implementation of Ivan Sutherland’s 1965 idea of the ultimate display: “The ultimate display would, of course, be a room within which the computer can control the existence of matter …” (Sutherland, 1965, Proceedings of IFIPS Congress 2:506-508).

  6. Self-organizing actin waves that simulate phagocytic cup structures.

    PubMed

    Gerisch, Günther

    2010-03-18

    This report deals with actin waves that are spontaneously generated on the planar, substrate-attached surface of Dictyostelium cells. These waves have the following characteristics. (1) They are circular structures of varying shape, capable of changing the direction of propagation. (2) The waves propagate by treadmilling with a recovery of actin incorporation after photobleaching of less than 10 seconds. (3) The waves are associated with actin-binding proteins in an ordered 3-dimensional organization: with myosin-IB at the front and close to the membrane, the Arp2/3 complex throughout the wave, and coronin at the cytoplasmic face and back of the wave. Coronin is a marker of disassembling actin structures. (4) The waves separate two areas of the cell cortex that differ in actin structure and phosphoinositide composition of the membrane. The waves arise at the border of membrane areas rich in phosphatidylinositol (3,4,5) trisphosphate (PIP3). The inhibition of PIP3 synthesis reversibly inhibits wave formation. (5) The actin wave and PIP3 patterns resemble 2-dimensional projections of phagocytic cups, suggesting that they are involved in the scanning of surfaces for particles to be taken up.PACS Codes: 87.16.Ln, 87.19.lp, 89.75.Fb.

  7. Our Everyday Cup of Coffee: The Chemistry behind Its Magic

    NASA Astrophysics Data System (ADS)

    Petracco, Marino

    2005-08-01

    Coffee beverages are so popular all over the world that there is hardly any need to describe them. But underlying this seemingly commonplace beverage there is a whole realm worth serious scientific study. The complexity of the raw seed matrix, made even more intricate when roasted, requires a deep understanding of its chemical nature. While coffee is not consumed for nutritional purposes, it is appreciated for its taste appeal along with its stimulating effects on mental and physical activity. The attention to quality is of paramount importance to both of these aspects to supply the customers with a pleasant and wholesome product. The chemical approach to the sensory sphere has seen the development of increasingly sophisticated analytical methods where the parts per billion of volatile aromas are not the ultimate frontier of detection limits. In spite of the progress of instrumental techniques, the cup-testing approach still remains the final assessment tool to obtain the approval for choosing the right plant and for conveying the product to the market. This is even truer when espresso, the fashionable type of coffee brewing methods, is considered.

  8. Match statistics related to winning in the group stage of 2014 Brazil FIFA World Cup.

    PubMed

    Liu, Hongyou; Gomez, Miguel-Ángel; Lago-Peñas, Carlos; Sampaio, Jaime

    2015-01-01

    Identifying match statistics that strongly contribute to winning in football matches is a very important step towards a more predictive and prescriptive performance analysis. The current study aimed to determine relationships between 24 match statistics and the match outcome (win, loss and draw) in all games and close games of the group stage of FIFA World Cup (2014, Brazil) by employing the generalised linear model. The cumulative logistic regression was run in the model taking the value of each match statistic as independent variable to predict the logarithm of the odds of winning. Relationships were assessed as effects of a two-standard-deviation increase in the value of each variable on the change in the probability of a team winning a match. Non-clinical magnitude-based inferences were employed and were evaluated by using the smallest worthwhile change. Results showed that for all the games, nine match statistics had clearly positive effects on the probability of winning (Shot, Shot on Target, Shot from Counter Attack, Shot from Inside Area, Ball Possession, Short Pass, Average Pass Streak, Aerial Advantage and Tackle), four had clearly negative effects (Shot Blocked, Cross, Dribble and Red Card), other 12 statistics had either trivial or unclear effects. While for the close games, the effects of Aerial Advantage and Yellow Card turned to trivial and clearly negative, respectively. Information from the tactical modelling can provide a more thorough and objective match understanding to coaches and performance analysts for evaluating post-match performances and for scouting upcoming oppositions.

  9. The magic cup: great apes and domestic dogs (Canis familiaris) individuate objects according to their properties.

    PubMed

    Bräuer, Juliane; Call, Josep

    2011-08-01

    Despite current interest in dog (Canis familiaris) cognition, very little is known about how dogs represent objects and how they compare with other species, such as the great apes. Therefore, we investigated how dogs and great apes (chimpanzees [Pan troglodytes], bonobos [Pan paniscus], orangutans [Pongo pygmaeus], gorillas [Gorilla gorilla]) individuate objects in a classical violation of expectation paradigm. We used a container (magic cup) with a double bottom that allowed us to change the type of food that subjects had seen being placed in the container. Using a 2 × 2 design, we varied whether subjects received a generally preferred food and whether the food was substituted (surprise trials) or not (baseline trials). Apes showed increased begging and looking behaviors and dogs showed increased smelling behavior. Both species stayed near the experimenter more frequently in the surprise trials compared with baseline trials. Both species reacted to positive (i.e., good food substituted for bad food) and negative (i.e., bad food substituted for good food) surprises. These results suggest that apes and dogs were able to individuate objects according to their properties or type in comparable ways. In addition, we looked for frustration and elation effects, but subjects' behaviors were not influenced by the food they saw and which they received in previous trials.

  10. Evolution and diverse roles of the CUP-SHAPED COTYLEDON genes in Arabidopsis leaf development.

    PubMed

    Hasson, Alice; Plessis, Anne; Blein, Thomas; Adroher, Bernard; Grigg, Stephen; Tsiantis, Miltos; Boudaoud, Arezki; Damerval, Catherine; Laufs, Patrick

    2011-01-01

    CUP-SHAPED COTYLEDON2 (CUC2) and the interacting microRNA miR164 regulate leaf margin dissection. Here, we further investigate the evolution and the specific roles of the CUC1 to CUC3 genes during Arabidopsis thaliana leaf serration. We show that CUC2 is essential for dissecting the leaves of a wide range of lobed/serrated Arabidopsis lines. Inactivation of CUC3 leads to a partial suppression of the serrations, indicating a role for this gene in leaf shaping. Morphometric analysis of leaf development and genetic analysis provide evidence for different temporal contributions of CUC2 and CUC3. Chimeric constructs mixing CUC regulatory sequences with different coding sequences reveal both redundant and specific roles for the three CUC genes that could be traced back to changes in their expression pattern or protein activity. In particular, we show that CUC1 triggers the formation of leaflets when ectopically expressed instead of CUC2 in the developing leaves. These divergent fates of the CUC1 and CUC2 genes after their formation by the duplication of a common ancestor is consistent with the signature of positive selection detected on the ancestral branch to CUC1. Combining experimental observations with the retraced origin of the CUC genes in the Brassicales, we propose an evolutionary scenario for the CUC genes.

  11. Capuchin monkeys (Cebus apella) use positive, but not negative, auditory cues to infer food location.

    PubMed

    Heimbauer, Lisa A; Antworth, Rebecca L; Owren, Michael J

    2012-01-01

    Nonhuman primates appear to capitalize more effectively on visual cues than corresponding auditory versions. For example, studies of inferential reasoning have shown that monkeys and apes readily respond to seeing that food is present ("positive" cuing) or absent ("negative" cuing). Performance is markedly less effective with auditory cues, with many subjects failing to use this input. Extending recent work, we tested eight captive tufted capuchins (Cebus apella) in locating food using positive and negative cues in visual and auditory domains. The monkeys chose between two opaque cups to receive food contained in one of them. Cup contents were either shown or shaken, providing location cues from both cups, positive cues only from the baited cup, or negative cues from the empty cup. As in previous work, subjects readily used both positive and negative visual cues to secure reward. However, auditory outcomes were both similar to and different from those of earlier studies. Specifically, all subjects came to exploit positive auditory cues, but none responded to negative versions. The animals were also clearly different in visual versus auditory performance. Results indicate that a significant proportion of capuchins may be able to use positive auditory cues, with experience and learning likely playing a critical role. These findings raise the possibility that experience may be significant in visually based performance in this task as well, and highlight that coming to grips with evident differences between visual versus auditory processing may be important for understanding primate cognition more generally.

  12. Pulsatile dry cupping in patients with osteoarthritis of the knee – a randomized controlled exploratory trial

    PubMed Central

    2012-01-01

    Introduction Cupping is used in various traditional medicine forms to relieve pain in musculoskeletal diseases. The aim of this study was to investigate the effectiveness of cupping in relieving the symptoms of knee osteoarthritis (OA). Methods In a two-group, randomized controlled exploratory pilot study patients with a clinically and radiological confirmed knee OA (Kellgren-Lawrence Grading Scale: 2-4) and a pain intensity > 40 mm on a 100 mm visual analogue scale (VAS) were included. 40 Patients were randomized to either 8 sessions of pulsatile dry cupping within 4 weeks or no intervention (control). Paracetamol was allowed on demand for both groups. Outcomes were the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) score, the pain intensity on a VAS (0 mm = no pain to 100 mm = maximum intensity) and Quality of Life (SF-36) 4 and 12 weeks after randomization. Use of Paracetamol was documented within the 4-week treatment period. Analyses were performed by analysis of covariance adjusting for the baseline value for each outcome. Results 21 patients were allocated to the cupping group (5 male; mean age 68 ± SD 7.2) and 19 to the control group (8 male; 69 ± 6.8). After 4 weeks the WOMAC global score improved significantly more in the cupping group with a mean of 27.7 (95% confidence interval 22.1; 33.3) compared to 42.2 (36.3; 48.1) in the control group (p = 0.001). After 12 weeks the WOMAC global score were still significantly different in favor for cupping (31.0 (24.9; 37.2) vs. 40.8 (34.4; 47.3) p = 0.032), however the WOMAC subscores for pain and stiffness were not significant anymore. Significantly better outcomes in the cupping group were also observed for pain intensity on VAS and for the SF-36 Physical Component Scale compared to the control group after 4 and 12 weeks. No significant difference was observed for the SF-36 Mental Component Scale and the total number of consumed Paracetamol tablets

  13. Relative merits of polystyrene foam and paper in hot drink cups: Implications for packaging

    NASA Astrophysics Data System (ADS)

    Hocking, Martin B.

    1991-11-01

    An analysis of the overall relative merits of the use of uncoated paper vs molded polystyrene bead foam in single-use 8-oz cups is described here as a manageable example of the use of paper vs plastics in packaging. In raw material requirements the paper cup required about 2.5 times its finished weight of raw wood and about the same hydrocarbon fueling requirement as is needed for the polystyrene foam cup. To process the raw materials about six times as much steam, 13 times as much electric power, and twice as much cooling water are consumed to produce the paper cup as compared to the polystyrene foam cup. Emission rates to air are similar and to water are generally higher for the paper cup. Virtually all primary use factors favor polystyrene foam over paper. Once used both cup types may be recycled. Landfill disposal of the two items under dry conditions will occupy similar landfill volumes after compaction and will confer similarly slow to nonexistent decomposition to either option. Under wet conditions polystyrene foam will not readily degrade, but may help other materials to do so. Paper under wet conditions will biodegrade to produce methane, a significant greenhouse gas, biochemical oxygen demand to any leachate, and instability to the land surface during the process. Both materials can be incinerated cleanly in a municipal waste stream with the option of energy recovery, to yield an ash volume of 2% 5% of the incoming waste volume. Overall this analysis would suggest that polystyrene foam, with an extension to plastics in general, should be given more evenhanded consideration relative to paper in packaging applications than is currently the case.

  14. No increased risk of early revision during the implementation phase of new cup designs

    PubMed Central

    Björk, Mathias; Nemes, Szilard; Rolfson, Ola; Jolbäck, Per; Kärrholm, Johan

    2016-01-01

    Background and purpose — In Sweden, less than 5% of patients who undergo total hip arthroplasty (THA) have revision. Younger patients have an increased risk of revision. New prosthetic designs are being introduced in order to improve outcomes further. We investigated whether the introductory phase of new cup designs would increase the revision rate. Patients and methods — All THAs and first-time cup revisions performed from 1993 through 2011 were identified in the Swedish Hip Arthroplasty Register. The 15 types of cups used in more than 500 operations and inserted in more than 50 cases in each hospital (n = 52,903) were selected. All cups were given an order number, based on the order in which the cup had been inserted at each hospital. The influence of order number on the risk of revision was analyzed in a regression model, which was adjusted for potentially confounding demographic and surgical data. Revision within 2 years for all reasons (n = 940) was used as primary endpoint. Changes in the risk of revision based on the order number were analyzed using a spline. Results — The order number of the cup had no influence on the risk of early revision (p ≥ 0.7). Categorizing the order number using cutoff values obtained from the splines did not result in any statistically significant changes in risk of revision (p ≥ 0.2). Interpretation — We did not find any increased risk of early revision during the implementation phase of new cup designs. This finding is unexpected, and partly conflicts with data from other registries. The structured and stepwise introduction of new prosthesis designs, facilitated by the annual feedback from the Swedish Hip Arthroplasty Register, may partly explain this discrepancy. PMID:27168095

  15. Aerobic power and peak power of elite America's Cup sailors.

    PubMed

    Neville, Vernon; Pain, Matthew T G; Folland, Jonathan P

    2009-05-01

    Big-boat yacht racing is one of the only able bodied sporting activities where standing arm-cranking ('grinding') is the primary physical activity. However, the physiological capabilities of elite sailors for standing arm-cranking have been largely unreported. The purpose of the study was to assess aerobic parameters, VO(2peak) and onset of blood lactate (OBLA), and anaerobic performance, torque-crank velocity and power-crank velocity relationships and therefore peak power (P (max)) and optimum crank-velocity (omega(opt)), of America's Cup sailors during standing arm-cranking. Thirty-three elite professional sailors performed a step test to exhaustion, and a subset of ten grinders performed maximal 7 s isokinetic sprints at different crank velocities, using a standing arm-crank ergometer. VO(2peak) was 4.7 +/- 0.5 L/min (range 3.6-5.5 L/min) at a power output of 332 +/- 44 W (range 235-425 W). OBLA occurred at a power output of 202 +/- 31 W (61% of W(max)) and VO(2) of 3.3 +/- 0.4 L/min (71% of VO(2peak)). The torque-crank velocity relationship was linear for all participants (r = 0.9 +/- 0.1). P (max) was 1,420 +/- 37 W (range 1,192-1,617 W), and omega(opt) was 125 +/- 6 rpm. These data are among the highest upper-body anaerobic and aerobic power values reported. The unique nature of these athletes, with their high fat-free mass and specific selection and training for standing arm cranking, likely accounts for the high values. The influence of crank velocity on peak power implies that power production during on-board 'grinding' may be optimised through the use of appropriate gear-ratios and the development of efficient gear change mechanisms.

  16. Cup anemometer response to the wind turbulence-measurement of the horizontal wind variance

    NASA Astrophysics Data System (ADS)

    Yahaya, S.; Frangi, J.

    2004-10-01

    This paper presents some dynamic characteristics of an opto-electronic cup anemometer model in relation to its response to the wind turbulence. It is based on experimental data of the natural wind turbulence measured both by an ultrasonic anemometer and two samples of the mentioned cup anemometer. The distance constants of the latter devices measured in a wind tunnel are in good agreement with those determined by the spectral analysis method proposed in this study. In addition, the study shows that the linear compensation of the cup anemometer response, beyond the cutoff frequency, is limited to a given frequency, characteristic of the device. Beyond this frequency, the compensation effectiveness relies mainly on the wind characteristics, particularly the direction variability and the horizontal turbulence intensity. Finally, this study demonstrates the potential of fast cup anemometers to measure some turbulence parameters (like wind variance) with errors of the magnitude as those deriving from the mean speed measurements. This result proves that fast cup anemometers can be used to assess some turbulence parameters, especially for long-term measurements in severe climate conditions (icing, snowing or sandy storm weathers).

  17. Development of cup-shaped micro-electromechanical systems-based vector hydrophone

    NASA Astrophysics Data System (ADS)

    Xu, Wei; Liu, Yuan; Zhang, Guojun; Wang, Renxin; Xue, Chenyang; Zhang, Wendong; Liu, Jun

    2016-09-01

    Similar to the vital performance factors, the receiving sensitivity and the bandwidth exist interactively in the micro-electromechanical systems (MEMS)-based vector hydrophones. Some existing methods can improve the sensitivity of the hydrophone, but these improvements are usually gained at a cost of the bandwidth. However, the cup-shaped MEMS vector hydrophone that is presented in this paper can improve its sensitivity while retaining a sufficient bandwidth. The cup-shaped structure acts as a new sensing unit in the MEMS vector hydrophone, replacing the bionic columnar hair that was previously used for sensing. The relationships between the parameters of the cup-shaped structure and the sensitivity of the vector hydrophone were determined by a theoretical deduction. In addition, simulation analyses were performed, and optimized structural parameters were obtained in this work. ANSYS 15.0 simulation was used to derive the optimum characteristics for the cup-shaped structure. The results of the calibration experiments showed that the sensitivity reached up to -188.5 dB (gain of 40 dB, 1 kHz, 0 dB@1 V/μPa), and the bandwidth was in the 20 Hz-1 kHz range, which is sufficient for an underwater acoustic detection at low frequencies. This work has, thus, proved that the cup-shaped vector hydrophone has superior properties for the engineering applications.

  18. Antidoping programme and biological monitoring before and during the 2014 FIFA World Cup Brazil

    PubMed Central

    Baume, Norbert; Jan, Nicolas; Emery, Caroline; Mandanis, Béatrice; Schweizer, Carine; Giraud, Sylvain; Leuenberger, Nicolas; Marclay, François; Nicoli, Raul; Perrenoud, Laurent; Robinson, Neil; Dvorak, Jiri; Saugy, Martial

    2015-01-01

    Background The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. Aim To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. Methods All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2–8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. Results The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. Conclusions Logistical issues linked to biological samples collection, and the overseas shipment during the World Cup did not impair the quality of the analyses, especially when used as the biological passport of football players. PMID:25878079

  19. Characterization and correction of cupping effect artefacts in cone beam CT

    PubMed Central

    Hunter, AK; McDavid, WD

    2012-01-01

    Objective The purpose of this study was to demonstrate and correct the cupping effect artefact that occurs owing to the presence of beam hardening and scatter radiation during image acquisition in cone beam CT (CBCT). Methods A uniform aluminium cylinder (6061) was used to demonstrate the cupping effect artefact on the Planmeca Promax 3D CBCT unit (Planmeca OY, Helsinki, Finland). The cupping effect was studied using a line profile plot of the grey level values using ImageJ software (National Institutes of Health, Bethesda, MD). A hardware-based correction method using copper pre-filtration was used to address this artefact caused by beam hardening and a software-based subtraction algorithm was used to address scatter contamination. Results The hardware-based correction used to address the effects of beam hardening suppressed the cupping effect artefact but did not eliminate it. The software-based correction used to address the effects of scatter resulted in elimination of the cupping effect artefact. Conclusion Compensating for the presence of beam hardening and scatter radiation improves grey level uniformity in CBCT. PMID:22378754

  20. Improved automated optic cup segmentation based on detection of blood vessel bends in retinal fundus images.

    PubMed

    Hatanaka, Yuji; Nagahata, Yuuki; Muramatsu, Chisako; Okumura, Susumu; Ogohara, Kazunori; Sawada, Akira; Ishida, Kyoko; Yamamoto, Tetsuya; Fujita, Hiroshi

    2014-01-01

    Glaucoma is a leading cause of permanent blindness. Retinal imaging is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, ophthalmologists may determine the cup and disc areas and diagnose glaucoma using a vertical optic cup-to-disc (C/D) ratio and a rim-to-disc (R/D) ratio. Previously we proposed a method to determine cup edge by analyzing a vertical profile of pixel values, but this method provided a cup edge smaller than that of an ophthalmologist. This paper describes an improved method using the locations of the blood vessel bends. The blood vessels were detected by a concentration feature determined from the density gradient. The blood vessel bends were detected by tracking the blood vessels from the disc edge to the primary cup edge, which was determined by our previous method. Lastly, the vertical C/D ratio and the R/D ratio were calculated. Using forty-four images, including 32 glaucoma images, the AUCs of both the vertical C/D ratio and R/D ratio by this proposed method were 0.966 and 0.936, respectively.

  1. Corking Nitrogen-Doped Carbon Nanotube Cups with Gold Nanoparticles for Biodegradable Drug Delivery Applications

    PubMed Central

    Burkert, Seth C.; Star, Alexander

    2015-01-01

    Carbon nanomaterials have been proposed as effective drug delivery devices; however their perceived biopersistence and toxicological profile may hinder their applications in medical therapeutics. Nitrogen doping of carbon nanotubes results in a unique “stacked-cup” structure, with cups held together through van der Waals forces. Disrupting these weak interactions yields individual and short-stacked nanocups which can be subsequently corked with gold nanoparticles resulting in sealed containers for delivery of cargo. Peroxidase-catalyzed reactions can effectively uncork these containers, followed by complete degradation of the graphitic capsule, resulting in effective release of therapeutic cargo while minimizing harmful side effects. The protocols reported herein describe the synthesis of stacked nitrogen-doped carbon nanotube cups followed by effective separation into individual cups and gold nanoparticle cork formation resulting in loaded and sealed containers. PMID:26629615

  2. Effects of Turbulence and Flow Inclination on the Performance of Cup Anemometers in the Field

    NASA Astrophysics Data System (ADS)

    Papadopoulos, K.H.; Stefantos, N.C.; Paulsen, U.S.; Morfiadakis, E.

    Four commercial and one research cup anemometers were comparatively tested in a complex terrain site to quantify the effects of turbulence and flow inclination on the wind speed measurements. The difference of the mean windspeed reading between the anemometers was as much as 2% for wind directions where the mean flow was horizontal. This difference was large enough to be attributed to the well-known overspeeding effect related to the differing distance constant (ranging from 1.7 to 5 m) of the cup anemometers. The application of a theoretical model of the cup-anemometer behaviour in athree-dimensional turbulent wind field proved successful in explaining theobserved differences.Additional measurements were taken with the anemometers tilted at known angles into and out of the incident wind flow. Thus, a field-derived angular response curve is constructed for each anemometer and the deviations from publishedwind-tunnel results are discussed.

  3. Update on the diagnosis of cancer of unknown primary (CUP) origin.

    PubMed

    Ariza, Aurelio; Balañá, Carmen; Concha, Ángel; Hitt, Ricardo; Homet, Blanca; Matilla, Alfredo; Alba, Emilio

    2011-07-01

    The cancer of unknown primary (CUP) concept encompasses a heterogeneous group of cancers that are difficult to diagnose and that show diverse clinical and histopathological features. Currently, CUP is the fifth most frequent cancer diagnosis in women and the eighth in men. The ongoing development of new therapies specific to the various cancer types makes mandatory the identification of the primary tumour in CUP patients, so that they may benefit from advances in therapy and improvements in prognosis. Molecular detection techniques provide very useful tools in the prediction of primary tumour types and must be used together with clinical, histopathological and IHC diagnostic techniques. Steady collaboration and fluid communication between oncologists and pathologists is of the utmost importance for the correct interpretation of tests and the personalised approach required by each individual case. Work in multidisciplinary teams will result in significant changes in the diagnosis and treatment of these patients.

  4. Cultural change--empowerment at Sweetheart Cup Company, Inc., Bakery Division.

    PubMed

    Altomonte, W; Mooney, W; Sheldon, D H

    1999-08-01

    Sweetheart Cup Company always has been associated with fun products--fast food containers, straws, ballpark drink glasses, and maybe the most fun of all--ice cream cones! But making these products of pleasantry at times has not been as festive as it would seem. Sweetheart Cup Company has had its ups and downs in terms of many of the typical manufacturing measurements, but in 1994--under the direction of newly appointed Chief Operating Officer Bill McLaughlin--Sweetheart Cup Company embarked on a new mission. This time everyone would be involved, from headquarters staff in Owings Mills to the fourth-floor oven area workers in the Dallas bakery. The new process goal, "Business Excellence," as we called it, was really an implementation of Class A ERP/MRP II.

  5. Enhanced surveillance of infectious diseases : the 2006 FIFA World Cup experience, Germany.

    PubMed

    Schenkel, K; Williams, C; Eckmanns, T; Poggensee, G; Benzler, J; Josephsen, J; Krause, Gerard

    2006-01-01

    The 2006 FIFA World Cup was held in 12 German cities between 9 June and 9 July 2006. We identified a need to accelerate and sensitise the pre-existing surveillance system for infectious diseases in order to timely detect adverse health events during the World Cup. Enhanced surveillance, based on Germany's pre-existing system of mandatory notifications was conducted between 7 June and 11 July 2006 in the 12 World Cup cities by: accelerating frequency of electronic data transmission of case-definition based notifiable diseases from weekly to daily transmission, additional reporting of non-case definition-based infectious disease events, lay and expert press screening and intensifying communication between all stakeholders of the surveillance system. Median delay of notification data transmission from the community to the federal level was reduced from three days to one day. The enhanced reporting system detected a norovirus outbreak in the International Broadcast Centre in Munich with 61 epidemiologically linked cases within the first week after onset, as well as four single cases related to the World Cup, two of them with relevance for the International Health Regulations. After the World Cup, all surveillance stakeholders agreed that communication between local, state and federal levels had improved considerably. Unlike the majority of health planners of previous mass gatherings in the last decade we did not introduce syndromic surveillance. Nevertheless, enhancement of infectious disease surveillance successfully detected adverse health events in a timely manner during the FIFA World Cup. Additionally, it provided a valuable communication and networking exercise for potentially critical health-related events. We recommend continuing daily notification data transmission for routine infectious disease surveillance in Germany.

  6. NCI Takes Back the Defelice Cup at Ninth Annual Golf Tournament | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer After being down by a point in the morning, NCI reclaimed the Defelice Cup trophy from Leidos Biomedical Research, with a final score of 12 ½ to 11 ½, at the ninth annual Ronald H. Defelice Golf Tournament, held Oct. 13. “The tightest matches in the nine-year history of this cup competition resulted in a narrow victory for NCI and allowed NCI to take a 5–4 victory total,” said Denny Dougherty, one of the team captains for Leidos Biomed and a retired senior subcontracts advisor at what was formerly SAIC-Frederick.

  7. Stripline fast faraday cup for measuring GHz structure of ion beams

    DOEpatents

    Bogaty, John M.

    1992-01-01

    The Stripline Fast Faraday Cup is a device which is used to quantitatively and qualitatively measure gigahertz time structure characteristics of ion beams with energies up to at least 30 Mev per nucleon. A stripline geometry is employed in conjunction with an electrostatic screen and a Faraday cup to provide for analysis of the structural characteristics of an ion beam. The stripline geometry allows for a large reduction in the size of the instrument while the electrostatic screen permits measurements of the properties associated with low speed ion beams.

  8. HiCUP: pipeline for mapping and processing Hi-C data.

    PubMed

    Wingett, Steven; Ewels, Philip; Furlan-Magaril, Mayra; Nagano, Takashi; Schoenfelder, Stefan; Fraser, Peter; Andrews, Simon

    2015-01-01

    HiCUP is a pipeline for processing sequence data generated by Hi-C and Capture Hi-C (CHi-C) experiments, which are techniques used to investigate three-dimensional genomic organisation. The pipeline maps data to a specified reference genome and removes artefacts that would otherwise hinder subsequent analysis. HiCUP also produces an easy-to-interpret yet detailed quality control (QC) report that assists in refining experimental protocols for future studies. The software is freely available and has already been used for processing Hi-C and CHi-C data in several recently published peer-reviewed studies.

  9. Femoral neck fracture following intramedullary nailing with misplacement of an end cup: report of two cases

    PubMed Central

    Mańkowski, Bartosz; Kierzynka, Grzegorz

    2008-01-01

    Femoral neck fracture is an unusual complication of intramedullary fixation of a broken femur. We report on two cases of femoral neck fractures attributed to misplacement of an end cup and subsequent invasive maneuvers in an effort to remove it. Iatrogenic fractures of the femoral neck during or after intramedullary nailing are reported in the medical literature. Authors associate it with many possible technical mistakes performed during the procedure, yet no complications after missed end cup placement were noted. We suggest that the fractures described below were a consequence of injury to the vascular supply and bone stock of the initially intact femoral neck. PMID:19384634

  10. Cup-Drawing Behavior of High-Strength Steel Sheets Containing Different Volume Fractions of Martensite

    SciTech Connect

    Choi, Shi-Hoon; Kim, Dae-Wan; Yang, Hoe-Seok; Han, Seong-Ho; Yoon, Jeong Whan

    2010-06-15

    Planar anisotropy and cup-drawing behavior were investigated for high-strength steel sheets containing different volume fractions of martensite. Macrotexture analysis using XRD was conducted to capture the effect of crystallographic orientation on the planar anisotropy of high-strength steel sheets. A phenomenological yield function, Yld96, which accounts for the anisotropy of yield stress and r-values, was implemented into ABAQUS using the user subroutine UMAT. Cup drawing of high-strength steel sheets was simulated using the FEM code. The profiles of earing and thickness strain were compared with the experimentally measured results.

  11. Local mapping for the middle-size league of RoboCup

    NASA Astrophysics Data System (ADS)

    He, Qicheng; Yang, Yimin; Zhang, Xuexi; Huang, Yanbiao

    2007-11-01

    Aiming at making up the limitation of catadioptric vision system that lacks of nearby image information, which is used for the middle-size league of RoboCup - The World Cup of Soccer Robots, this paper introduces the monocular front vision process with the purpose of improving the primary system. The paper puts forward the idea of the monocular front vision process at first, explains the algorithm of every module in detail, and comes up with the result as well as analyzes it according to the experiment at last.

  12. Effects of the 2010 World Cup football tournament on emergency department assault attendances in England.

    PubMed

    Quigg, Zara; Hughes, Karen; Bellis, Mark A

    2013-06-01

    We explore the impact of the 2010 World Cup, held in South Africa, on levels of assault attendances to 15 emergency departments in England. The majority (70.1%) of assault attendees during the 2010 World Cup was male and aged 18-34 years (52.5%). Assault attendances increased by 37.5% on the days that England played (P 001). Preparation for major sporting events in non-host countries should include violence prevention activity. Emergency department data can be used to identify violence associated with such events and thus inform both the targeting of prevention efforts and assessments of their effectiveness.

  13. Addendum: Safety Standards for Gua sha (press-stroking) and Ba guan (cupping).

    PubMed

    Nielsen, Arya; Kligler, Ben; Koll, Brian S

    2014-06-01

    Our previous article Safety Standards for Gua sha (press-stroking) and Baguan (cupping) discussed the risk of transfer of blood-borne pathogens with Gua sha and Ba guan, identified Gua sha and Ba guan 'instrument criticality' as semi-critical and offered recommendations for safe practice based on hospital disinfection standards. Based on the article's feedback, we feel the need to clarify that Gua sha and Ba guan instruments, if intended for reuse, must undergo high level disinfection (HLD) or, in the case of 'wet-cupping', sterilization. We update our recommendations to be amenable to both private practice and education settings.

  14. HiCUP: pipeline for mapping and processing Hi-C data

    PubMed Central

    Wingett, Steven; Ewels, Philip; Furlan-Magaril, Mayra; Nagano, Takashi; Schoenfelder, Stefan; Fraser, Peter; Andrews, Simon

    2015-01-01

    HiCUP is a pipeline for processing sequence data generated by Hi-C and Capture Hi-C (CHi-C) experiments, which are techniques used to investigate three-dimensional genomic organisation. The pipeline maps data to a specified reference genome and removes artefacts that would otherwise hinder subsequent analysis. HiCUP also produces an easy-to-interpret yet detailed quality control (QC) report that assists in refining experimental protocols for future studies. The software is freely available and has already been used for processing Hi-C and CHi-C data in several recently published peer-reviewed studies. PMID:26835000

  15. Balls, cups, and quasi-potentials: quantifying stability in stochastic systems.

    PubMed

    Nolting, Ben C; Abbott, Karen C

    2016-04-01

    When a system has more than one stable state, how can the stability of these states be compared? This deceptively simple question has important consequences for ecosystems, because systems with alternative stable states can undergo dramatic regime shifts. The probability, frequency, duration, and dynamics of these shifts will all depend on the relative stability of the stable states. Unfortunately, the concept of "stability" in ecology has suffered from substantial confusion and this is particularly problematic for systems where stochastic perturbations can cause shifts between coexisting alternative stable states. A useful way to visualize stable states in stochastic systems is with a ball-in-cup-diagram, in which the state of the system is represented as the position of a ball rolling on a surface, and the random perturbations can push the ball from one basin of attraction to another. The surface is determined by a potential function, which provides a natural stability metric. Systems amenable to this representation, called gradient systems, are quite rare, however. As a result, the potential function is not widely used and other approaches based on linear stability analysis have become standard. Linear stability analysis is designed for local analysis of deterministic systems and, as we show, can produce a highly misleading picture of how the system will behave under continual, stochastic perturbations. In this paper, we show how the potential function can be generalized so that it can be applied broadly, employing a concept from stochastic analysis called the quasi-potential. Using three classic ecological models, we demonstrate that the quasi-potential provides a useful way to quantify stability in stochastic systems. We show that the quasi-potential framework helps clarify long-standing confusion about stability in stochastic ecological systems, and we argue that ecologists should adopt it as a practical tool for analyzing these systems.

  16. 77 FR 50373 - Special Local Regulation and Safety Zone; America's Cup World Series Regattas, San Francisco Bay...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-21

    ... Cup Race Management DHS Department of Homeland Security FR Federal Register NPRM Notice of Proposed... Guard received notification from America's Cup Race Management (ACRM) that the race scheduled to occur... vessels operating during this media coverage. The time remaining before the scheduled August 26th...

  17. Demonstrating the Effects of Processing on the Structure and Physical Properties of Plastic Using Disposable PETE Cups

    ERIC Educational Resources Information Center

    Erk, Kendra A.; Rhein, Morgan; Krafcik, Matthew J.; Ydstie, Sophie

    2015-01-01

    An educational activity is described in which the structure and physical properties of disposable plastic cups were directly related to the method of processing. The mechanical properties of specimens cut from the walls of poly(ethylene terephthalate) (PETE) cups, oriented parallel and perpendicular to the thermoforming direction, were measured in…

  18. A congested football calendar and the wellbeing of players: correlation between match exposure of European footballers before the World Cup 2002 and their injuries and performances during that World Cup

    PubMed Central

    Ekstrand, J; Walden, M; Hagglund, M

    2004-01-01

    Objectives: To investigate the correlation between exposure of footballers in European clubs to match play in the months before the World Cup 2002 and their injuries and performances during that World Cup. Methods: The team doctors at 11 of the best football clubs in Europe prospectively recorded players' exposure and injuries during the 2001–2002 season (July 2001–May 2002). Sixty five players participated in the World Cup in Korea/Japan (June 2002). During the World Cup, the clubs reported injuries sustained by these players, and their performance was evaluated by three international experts. Results: The number of team matches during the season varied between 40 and 76 for the different countries involved. The individual player had a mean of 36 matches during the season. Top players played more matches, especially during the final period of the season. Players who participated in the World Cup played more matches during the season than those who did not (46 v 33 matches). World Cup players did not show any increased risk of injury during the season. About 29% incurred injuries during the World Cup, and 32% performed below their normal standard. The players who underperformed had played more matches during the 10 weeks before the World Cup than those who performed better than expected (12.5 v 9, p<0.05). Twenty three (60%) of the 38 players who had played more than one match a week before the World Cup incurred injuries or underperformed during the World Cup. Conclusions: There is considerable variation in the number of matches played per season in European professional football leagues. Top level players are obliged to play many matches especially during the final period of the season. PMID:15273193

  19. 'Our struggles are bigger than the World Cup': civic activism, state-society relations and the socio-political legacies of the 2010 FIFA World Cup.

    PubMed

    Cornelissen, Scarlett

    2012-06-01

    South Africa's hosting of the 2010 FIFA World Cup saw a large number of public demonstrations, strikes and other forms of civic campaigning. World Cup activism was both preceded and followed by extensive and intensifying public unrest and industrial action that in the period before the tournament, threatened to derail the event. This paper assesses the motivations, forms and implications of the activism during South Africa's staging of the FIFA finals and interprets them against the larger context of shifting state-society relations in the country. There are two purposes to the analysis. First, to explore the underlying internal social forces that gave shape to the protests at the time, and the possible influence of the exogenous politics of mega-event social mobilization. Second, the implications and outcomes of these dynamics for longer term socio-political processes in the country are considered. The activism displayed many of the features of the politics of contestation of sport mega-events today. Importantly, however, the activism stemmed from a particular systemic dynamic and reflected changing relations in the post-apartheid political community. Therefore, while the World Cup was used as a strategic opportunity by many advocacy groups, it was one that rather fleetingly and ambivalently presented an additional platform to such groups in an otherwise on-going set of political battles. Rather than a strong case study of sport's transformative capacity, the civic campaigning during South Africa's World Cup demonstrates the way a sport mega-event can be used as a strategic entry point by civil society groups in their engagement with the state, although this can occur with greater or lesser success.

  20. Two-dimensional and three-dimensional cup coverage in total hip arthroplasty with developmental dysplasia of the hip.

    PubMed

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2013-06-21

    We analyzed the mean difference and correlation between 2D cup coverage measured from different projections and three-dimensional (3D) cup coverage to investigate their precise relationship in total hip arthroplasty (THA) among patients with developmental dysplasia of the hip (DDH). We created DDH-THA models on six foam pelvic models. 3D cup coverage was measured using a motion capture system and imaging software. Digitally reconstructed radiographs with predetermined pelvic rotations were simulated using image processing software at three different angles of rotation around the long body axis (0°, 25° and 45°). 2D cup coverage was then measured on these reconstructed radiographs. The 3D technique showed excellent intra-observer (κ>0.98) and inter-observer (κ>0.99) reliability. The 2D technique tended to overestimate the real cup coverage by about 15%. The smallest difference between 2D and 3D cup coverage occurred when 2D measurement was performed on the radiographs with 45° of pelvic rotation toward the operated side (14.50%, P<0.0001), meanwhile, the highest correlation coefficient between 2D and 3D cup coverage was also observed when the 2D measurement was performed on the radiographs at this same pelvic rotation (r=0.67, P=0.0003). Published recommendations regarding the minimum cup coverage based on 2D measurement should be interpreted cautiously. The minimal cup coverage, as an intra-operative 3D parameter related to the long term fixation of the cup component, should be more accurately determined with intra-operative measurement.

  1. 76 FR 58108 - Safety Zone; Ryder Cup Captain's Duel Golf Shot, Chicago River, Chicago, IL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Ryder Cup Captain's Duel Golf Shot, Chicago River, Chicago, IL AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary safety zone on the Chicago River near Chicago, Illinois. This zone is intended...

  2. Technology and Teaching: Searching under Cups for Clues about Memory--An Online Demonstration

    ERIC Educational Resources Information Center

    Kahan, Todd A.; Mathis, Katherine M.

    2007-01-01

    An online demonstration, designed to enhance comprehension of Sternberg's (1966) short-term memory scanning task, involved rapidly searching under virtual cups for a ball. We randomly assigned students to 1 of 3 groups, all of whom read the same textbook description of Sternberg's work: A demonstration group used 3 search methods to look for balls…

  3. Open cup nests evolved from roofed nests in the early passerines.

    PubMed

    Price, J Jordan; Griffith, Simon C

    2017-02-08

    The architectural diversity of nests in the passerine birds (order Passeriformes) is thought to have played an important role in the adaptive radiation of this group, which now comprises more than half of avian species and occupies nearly all terrestrial ecosystems. Here, we present an extensive survey and ancestral state reconstruction of nest design across the passerines, focusing on early Australian lineages and including members of nearly all passerine families worldwide. Most passerines build open cup-shaped nests, whereas a minority build more elaborate domed structures with roofs. We provide strong evidence that, despite their relative rarity today, domed nests were constructed by the common ancestor of all modern passerines. Open cup nests evolved from enclosed domes at least four times independently during early passerine evolution, at least three of which occurred on the Australian continent, yielding several primarily cup-nesting clades that are now widespread and numerically dominant among passerines. Our results show that the ubiquitous and relatively simple cup-shaped nests of many birds today evolved multiple times convergently, suggesting adaptive benefits over earlier roofed designs.

  4. Purification of quadrol for microsequencing in the spinning-cup sequenator.

    PubMed

    Begg, G S; Leslie, B H; Morgan, F J

    1984-04-01

    Treatment of Quadrol buffer with isothiocyanatophenylthiocarbamylaminoethylaminopropyl glass (DITC glass) substantially reduces the impurities observed when this buffer is used with the spinning cup sequenator. Use of DITC glass-treated Quadrol buffer permits identification of PTH-amino acids from protein degradations down to 100 pmol.

  5. Cupping therapy: A prudent remedy for a plethora of medical ailments

    PubMed Central

    Mehta, Piyush; Dhapte, Vividha

    2015-01-01

    Since ancient times, complementary and alternative medicine (CAM; 補充與替代醫學 bǔ chōng yǔ tì dài yī xué) have played an important role in human health and welfare. Many therapeutic approaches in healthcare outside the realm of conventional medicine persist in various parts of the world. There is considerable scientific and commercial potential in CAM, which needs to be explored precisely. Cupping therapy (拔罐療法 bá guàn liáo fǎ), one of the CAM, is practiced across the world. This therapy is believed to act by correcting imbalances in the internal bio field, such as by restoring the flow of “Qi (氣qì)”. Cupping involves applying a heated cup to generate a partial vacuum that mobilizes the blood flow and promotes effective healing. This review outlines various tools and techniques of cupping therapy. PMID:26151023

  6. A newly designed big cup nitinol stent for gastric outlet obstruction

    PubMed Central

    Shi, Ding; Liao, Sheng-Hui; Geng, Jian-Ping

    2010-01-01

    AIM: To find out whether a newly designed big cup nitinol stent is suitable for treatment of patients with gastric outlet obstruction resulting from gastric cancer. METHODS: The new stent is composed of a proximal big cup segment (20 mm in length and 48-55 mm in diameter), a middle part (60 mm in length and 20 mm in diameter) covered by a polyethylene membrane and a distal sphericity (20 mm in length and 28 mm in diameter). Half of the proximal big cup segment is also covered by a polyethlene membrane, which is adjacent to the middle part of the stent. The stent is preloaded in a 6.0-mm-diameter introducer system. Thirteen patients with gastric outlet obstruction resulting from gastric cancer received the new stents under endoscopic and fluoroscopic guidance. RESULTS: Technical success was achieved in 12 of 13 (92.3%) patients. Among the 12 patients in whom endoscopic stent was placed successfully, the clinical success rate was 91.7% during a follow-up of average 6.5 mo. During the first month follow-up, the migration rate was 0%, recurrent obstruction 0% and gastric bleeding 8.3%. During the follow-up between 2-12 mo, no migration, recurrent obstruction and gastric bleeding occurred. CONCLUSION: The proximal big cup segment seems to be effective and promising for technical efficacy, clinical outcome, and preventing migration and tumor ingrowth and increasing the emptying rate of sinus ventriculi. PMID:20806440

  7. 77 FR 4501 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ... navigational Rules of the Road; (2) allowing for necessary commercial access in and out of any regulated area... with the America's Cup World Series regattas in 2012. The areas regulated by this special local... the vicinity of the City of San Francisco waterfront. The Coast Guard does not propose to...

  8. Using RoboCup in University-Level Computer Science Education

    ERIC Educational Resources Information Center

    Sklar, Elizabeth; Parsons, Simon; Stone, Peter

    2004-01-01

    In the education literature, team-based projects have proven to be an effective pedagogical methodology. We have been using "RoboCup" challenges as the basis for class projects in undergraduate and masters level courses. This article discusses several independent efforts in this direction and presents our work in the development of shared…

  9. Transgenic Mice Expressing Yeast CUP1 Exhibit Increased Copper Utilization from Feeds

    PubMed Central

    Chen, Zhenliang; Liao, Rongrong; Zhang, Xiangzhe; Wang, Qishan; Pan, Yuchun

    2014-01-01

    Copper is required for structural and catalytic properties of a variety of enzymes participating in many vital biological processes for growth and development. Feeds provide most of the copper as an essential micronutrient consumed by animals, but inorganic copper could not be utilized effectively. In the present study, we aimed to develop transgenic mouse models to test if copper utilization will be increased by providing the animals with an exogenous gene for generation of copper chelatin in saliva. Considering that the S. cerevisiae CUP1 gene encodes a Cys-rich protein that can bind copper as specifically as copper chelatin in yeast, we therefore constructed a transgene plasmid containing the CUP1 gene regulated for specific expression in the salivary glands by a promoter of gene coding pig parotid secretory protein. Transgenic CUP1 was highly expressed in the parotid and submandibular salivary glands and secreted in saliva as a 9-kDa copper-chelating protein. Expression of salivary copper-chelating proteins reduced fecal copper contents by 21.61% and increased body-weight by 12.97%, suggesting that chelating proteins improve the utilization and absorbed efficacy of copper. No negative effects on the health of the transgenic mice were found by blood biochemistry and histology analysis. These results demonstrate that the introduction of the salivary CUP1 transgene into animals offers a possible approach to increase the utilization efficiency of copper and decrease the fecal copper contents. PMID:25265503

  10. Evaluation of paladai cup feeding in breast-fed preterm infants compared with bottle feeding.

    PubMed

    Aloysius, A; Hickson, M

    2007-09-01

    This pilot study developed an appropriate procedure to evaluate the paladai cup compared to bottle feeding in preterm infants, using weighed napkins and video analysis to assess amount of spillage, volume consumed, time taken and physiological stability. Paladai results demonstrated increased spillage, increased feed times with more stress cues.

  11. Effect of Participation in a Cup Stacking Unit on Hand-Eye Coordination of Elementary Children

    ERIC Educational Resources Information Center

    Hart, Melanie A.; Smith, Lori A.; DeChant-Bruennig, Ann

    2006-01-01

    The purpose of this study was to empirically examine the influence of a cup stacking instructional unit on the hand-eye coordination of children. Participants (N = 104) consisted of three grade level groups (first/second, third and fourth). Within each grade level participants were randomly assigned to either an experimental or a control group.…

  12. The Empty Cup: "Teaching for Understanding" at 21st Century Edward Waters College. Occasional Paper #6

    ERIC Educational Resources Information Center

    Fluellen, Jerry E., Jr.

    2008-01-01

    What happens in a final project that fosters teaching for understanding? That inquiry calls to mind the Taoist belief that emptiness makes a cup useful. In the context of this paper, the inquiry organizes a narrative about how teaching for understanding surfaced in a "Theories of Learning" course at Edward Waters College. At a deeper…

  13. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  14. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  15. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  16. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  17. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  18. The Empty Cup (Power Teaching in a Digital Age). Occasional Paper #9

    ERIC Educational Resources Information Center

    Fluellen, Jerry E., Jr.

    2011-01-01

    What might count as a world class, national public education system in 2020? That empty cup took the floor at the 2010 Future of Learning (FoL) Summer Institute at Harvard University. It traveled from Longfellow Hall's lecture room on Appian Way to several learning groups scattered around campus. Though not deliberately created to think about…

  19. Simultaneous GC-MS determination of seven phthalates in total and migrated portions of paper cups.

    PubMed

    Park, Yu Na; Choi, Min Sun; Rehman, Shaheed Ur; Gye, Myung Chan; Yoo, Hye Hyun

    2016-05-01

    Phthalate acid esters are widely used as plasticizers to impart plastic flexibility in various industrial applications. In this study, the content of seven phthalates, dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), di-(2-ethylhexyl) adipate (DEHA), di-2-ethylhexyl phthalate (DEHP), di-n-octyl phthalate (DNOP), di-isononyl phthalate (DINP), and di-isodecyl phthalate (DIDP) were determined in paper cups using gas chromatography-mass spectrometry (GC-MS). In addition, the potential migration of these seven phthalates from paper cups into various food stimulants under different conditions was evaluated. The levels of DBP, DEHA, DEHP, and DNOP were in the ranges of 0.07-3.14, 0.16-42.69, 0.45-58.56, and 0.3-2.4 mg/kg, respectively. Meanwhile, BBP, DINP, and DIDP were not detected in most of the tested samples. In the migration test, DEHA was released to 50 % ethanol and n-heptane in a time-dependent manner and the maximum migration levels were 65.62 ± 3.61 and 95.56 ± 19.76 μg/L, respectively. The release of other phthalates was very low or negligible. These results demonstrated that paper cups are not a significant source of phthalate exposure; however, DEHA could be released from paper cups into alcoholic beverages or oily liquid beverages in the human diet.

  20. Spinal Epidural Hematoma Following Cupping Glass Treatment in an Infant With Hemophilia A.

    PubMed

    Fruchtman, Yariv; Dardik, Rima; Barg, Assaf Arie; Livnat, Tami; Feldman, Zeev; Rubinstein, Marina; Grinberg, Gahl; Rosenberg, Nurit; Kenet, Gili

    2016-06-01

    A 6 months old infant, diagnosed with a rare mutation causing severe hemophilia A, presented with spinal epidural hematoma. Parents later admitted the infant had glass cupping therapy performed within 2 weeks of the onset of symptoms. The rare mutation, rare bleeding complication, and the eventual course of therapy applied in this case will be discussed in our case report.

  1. [Recommendations for Chilean travelers to the FIFA World Cup 2014 in Brazil].

    PubMed

    Perret, Cecilia; Weitzel, Thomas

    2014-04-01

    This article provides a checklist of precautions and vaccines for Chilean travelers attending the FIFA World Cup 2014 in Brazil. It aims to help physicians to prepare visitors of this mass gathering and summarizes useful hints to avoid infectious diseases considering the circumstances and availabilities in Chile.

  2. A survey of the bacterial diversity in the cup filler of dental chair units

    PubMed Central

    Silva, Vítor; Figueira, Vânia; Figueiral, Helena; Manaia, Célia M.

    2011-01-01

    Water from the cup filler of dental chair units (CFDC) was observed to contain sphingomonads, environmental mycobacteria and methylobacteria, among other minor bacteria. Some of the bacteria detected are recognized opportunistic pathogens. Some of these, tended to persist over time. PMID:24031712

  3. Multimodal segmentation of optic disc and cup from stereo fundus and SD-OCT images

    NASA Astrophysics Data System (ADS)

    Miri, Mohammad Saleh; Lee, Kyungmoo; Niemeijer, Meindert; Abràmoff, Michael D.; Kwon, Young H.; Garvin, Mona K.

    2013-03-01

    Glaucoma is one of the major causes of blindness worldwide. One important structural parameter for the diagnosis and management of glaucoma is the cup-to-disc ratio (CDR), which tends to become larger as glaucoma progresses. While approaches exist for segmenting the optic disc and cup within fundus photographs, and more recently, within spectral-domain optical coherence tomography (SD-OCT) volumes, no approaches have been reported for the simultaneous segmentation of these structures within both modalities combined. In this work, a multimodal pixel-classification approach for the segmentation of the optic disc and cup within fundus photographs and SD-OCT volumes is presented. In particular, after segmentation of other important structures (such as the retinal layers and retinal blood vessels) and fundus-to-SD-OCT image registration, features are extracted from both modalities and a k-nearest-neighbor classification approach is used to classify each pixel as cup, rim, or background. The approach is evaluated on 70 multimodal image pairs from 35 subjects in a leave-10%-out fashion (by subject). A significant improvement in classification accuracy is obtained using the multimodal approach over that obtained from the corresponding unimodal approach (97.8% versus 95.2%; p < 0:05; paired t-test).

  4. Corrosion Behavior of Ceramic Cup of Blast Furnace Hearth by Liquid Iron and Slag

    NASA Astrophysics Data System (ADS)

    Li, Yanglong; Cheng, Shusen; Wang, Zhifeng

    2016-10-01

    Three kinds of sample bricks of ceramic cups for blast furnace hearth were studied by dynamic corrosion tests based on different corrosion systems, i.e., liquid iron system, liquid slag system and liquid iron-slag system. Considering the influence of temperature and sample rotational speed, the corrosion profiles and mass loss of the samples were analyzed. In addition, the microstructure of the corroded samples was observed by optical microscope (OM) and scanning electron microscope (SEM). It was found that the corrosion profiles could be divided into iron corrosion region, slag corrosion region and iron-slag corrosion region via corrosion degree after iron-slag corrosion experiment. The most serious corrosion occurred in iron-slag corrosion region. This is due to Marangoni effect, which promotes a slag film formed between liquid iron and ceramic cup and results in local corrosion. The corrosion of the samples deepened with increasing temperature of liquid iron and slag from 1,623 K to 1,823 K. The variation of slag composition had greater influence on the erosion degree than that of rotational speed in this experiment. Taking these results into account the ceramic cup composition should be close to slag composition to decrease the chemical reaction. A microporous and strong material should be applied for ceramic cup.

  5. UVI ThunnderBird Cup v2.0 Workshop: Worshop Analysis 2016.

    SciTech Connect

    Lee, Wellington K.; Morris, Tyler Jake; Chu, Andrew Chun-An; Russ, Joshua; Emerson-Lewis, Michelle

    2016-11-01

    The ThunderBird Cup v2.0 (TBC2) program falls under the Minority Serving Institution Pipeline Program (MSIPP) that aims to establish a world-class workforce development, education and research program that combines the strengths of Historically Black Colleges and Universities (HBCUs) and national laboratories to create a K-20 pipeline of students to participate in cybersecurity and related fields.

  6. ABQ ThunderBird Cup v3.0 Alpha Worksop: Workshop Analysis 2016.

    SciTech Connect

    Lee, Wellington K.; Morris, Tyler; Chu, Andrew; Gilmore, Katrina; Russ, Joshua; Carter, Aliyah

    2016-11-01

    The ThunderBird Cup v3.0 (TBC3) program falls under the Minority Serving Institution Pipeline Program (MSIPP) that aims to establish a world-class workforce development, education and research program that combines the strengths of Historically Black Colleges and Universities (HBCUs) and national laboratories to create a K-20 pipeline of students to participate in cybersecurity and related fields.

  7. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  8. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  9. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  10. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  11. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  12. Stability of Commercially Available Grape and Compounded Cherry Oral Vancomycin Preparations Stored in Syringes and Cups.

    PubMed

    Kirk, Loren; Lewis, Paul; Luu, Yao; Brown, Stacy

    2016-01-01

    The purpose of this study was to evaluate the stability of two preparations of vancomycin oral solution in two different storage containers, capped amber oral-dosing syringes and heat-sealed oral-dosing cups, stored under refrigerated conditions. Commercially available grape-flavored vancomycin oral preparation and compounded vancomycin for intravenous use in cherry syrup oral preparation were divided into 5-mL aliquots into heat-sealed plastic dosing cups and capped oral-dosing syringes. All samples were stored under refrigeration (2°C to 8°C) and evaluated at days 0, 3, 7, 14, 30, 60, and 90. For each evaluation, samples were visually inspected and analyzed for potency using a stability-indicating high-performance liquid chromatographic method with ultraviolet detection. Over the study period, at least 90% of the initial concentrations for the preparation and the product in both storage containers were retained at 60 days. The commercially available oral vancomycin further demonstrated stability within 90% out to 90 days in the syringe and the unit-dose cups. Visual inspection revealed no changes in the grape-flavored vancomycin oral preparation, but a detectable red-dye precipitate could be seen in the crevices of the dosing cups from the vancomycin in cherry syrup oral preparation after 60 days. Commercially available grape-flavored vancomycin oral preparation was stable up to 90 days, and com- pounded vancomycin for intravenous use in cherry syrup oral preparation maintained stability for 60 days when dispensed in capped amber polypropylene oral-dosing syringes and heat-sealed plastic dosing cups when stored at refrigerated conditions.

  13. Electromyographic analysis of masseter muscle in newborns during suction in breast, bottle or cup feeding

    PubMed Central

    2014-01-01

    Background When breastfeeding is difficult or impossible during the neonatal period, an analysis of muscle activity can help determine the best method for substituting it to promote the child’s development. The aim of this study was to analyze the electrical activity of the masseter muscle using surface electromyography during suction in term newborns by comparing breastfeeding, bottle and cup feeding. Methods An observational, cross-sectional analytical study was carried out on healthy, clinically stable term infants, assigned to receive either breast, or bottle or cup feeding. Setting was a Baby Friendly accredited hospital. Muscle activity was analyzed when each infant showed interest in sucking using surface electromyography. Root mean square averages (RMS) recorded in microvolts were transformed into percentages (normalization) of the reference value. The three groups were compared by ANOVA; the “stepwise” method of the multiple linear regression analysis tested the model which best defined the activity of the masseter muscle in the sample at a significance level of 5%. Results Participants were 81 full term newborns (27 per group), from 2 to 28 days of life. RMS values were lower for bottle (mean 44.2%, SD 14.1) than breast feeding (mean 58.3%, SD 12.7) (P = 0.003, ANOVA); cup feeding (52.5%, SD 18.2%) was not significantly different (P > 0.05). For every gram of weight increase, RMS increased by 0.010 units. Conclusions Masseter activity was significantly higher in breastfed newborns than in bottle-fed newborns, who presented the lowest RMS values. Levels of masseter activity during cup-feeding were between those of breast and bottle feeding, and did not significantly differ from either group. This study in healthy full term neonates endorses cup rather than bottle feeding as a temporary substitute for breastfeeding. PMID:24885762

  14. Values for bony acetabular roof angle and percentage femoral head cover in a selective ultrasound neonatal hip-screening programme: effect of age, sex and side.

    PubMed

    Wilkinson, A Graham; Wilkinson, Sally; Elton, Robert A

    2017-02-22

    Published maturation curves for bony acetabular roof or α angle (AA) and percentage femoral head cover (FHC) with age are sparse. We aimed to determine typical values for AA and FHC in 2236 infants referred to a selective ultrasound screening programme. There was increase in the values of first measurement of AA and FHC related to the logarithm of age. Males had greater values than females (P<0.001) and right hips had greater values than left (P<0.001) for both measurements. Significant side differences have not been reported previously. Treatment decisions should be made on the basis of sex, side and age-specific data.

  15. Cross-Modality Validation of Acetabular Surface Models Using 3-D Ultrasound Versus Magnetic Resonance Imaging in Normal and Dysplastic Infant Hips.

    PubMed

    Diederichs, Chad; Heath, Alana; Hareendranathan, Abhilash R; Zonoobi, Dornoosh; Kuntze, Gregor; Dulai, Sukhdeep; Mabee, Myles G; Ronsky, Janet L; Jaremko, Jacob L

    2016-09-01

    Current imaging diagnosis of developmental dysplasia of the hip (DDH) in infancy relies on 2-D ultrasound (US), which is highly operator-dependent. 3-D US offers more complete, and potentially more reliable, imaging of infant hip geometry. We sought to validate the fidelity of acetabular surface models obtained by 3-D US against those obtained concurrently by magnetic resonance imaging (MRI). 3-D US and MRI scans were performed on the same d in 20 infants with normal to severely dysplastic hips (mean age, 57 d; range 13-181 d). 3-D US was performed by two observers using a Philips VL13-5 probe. Coronal 3-D multi-echo data image combination (MEDIC) magnetic resonance (MR) images (1-mm slice thickness) were obtained, usually without sedation, in a 1.5 T Siemens unit. Acetabular surface models were generated for 40 hips from 3-D US and MRI using semi-automated tracing software, separately by three observers. For each hip, the 3-D US and MRI models were co-registered to overlap as closely as possible using Amira software, and the root mean square (RMS) distances between points on the models were computed. 3-D US scans took 3.2 s each. Inter-modality variability was visually minimal. Mean RMS distance between corresponding points on the acetabular surface at 3-D US and MRI was 0.4 ± 0.3 mm, with 95% confidence interval <1 mm. Mean RMS errors for inter-observer and intra-observer comparisons were significantly less for 3-D US than for MRI, while inter-scan and inter-modality comparisons showed no significant difference. Acetabular geometry was reproduced by 3-D US surface models within 1 mm of the corresponding 3-D MRI surface model, and the 3-D US models were more reliable. This validates the fidelity of 3-D US modeling and encourages future use of 3-D US in assessing infant acetabulum anatomy, which may be useful to detect and monitor treatment of hip dysplasia.

  16. The S2 Cu(i) site in CupA from Streptococcus pneumoniae is required for cellular copper resistance.

    PubMed

    Fu, Yue; Bruce, Kevin E; Wu, Hongwei; Giedroc, David P

    2016-01-01

    Pathogenic bacteria have evolved copper homeostasis and resistance systems for fighting copper toxicity imposed by the human immune system. Streptococcus pneumoniae is a respiratory pathogen that encodes an obligatorily membrane-anchored Cu(i) binding protein, CupA, and a P1B-type ATPase efflux transporter, CopA. The soluble, cytoplasmic domain of CupA (sCupA) contains a binuclear Cu(i) cluster consisting of S1 and S2 Cu(i) ions. The NMR solution structure of apo-sCupA reveals the same cupredoxin fold of Cu2-sCupA, except that the Cu(i) binding loop (residues 112-116, harboring S2 Cu ligands M113 and M115) is highly dynamic as documented by both backbone and side chain methionine methyl order parameters. In contrast to the more solvent exposed, lower affinity S2 Cu site, the high affinity S1 Cu-coordinating cysteines (C74, C111) are pre-organized in the apo-sCupA structure. Biological experiments reveal that the S1 site is largely dispensable for cellular Cu resistance and may be involved in buffering low cytoplasmic Cu(i). In contrast, the S2 site is essential for Cu resistance. Expression of a chimeric CopZ chaperone fused to the CupA transmembrane helix does not protect S. pneumoniae from copper toxicity and substitution of a predicted cytoplasm-facing Cu(i) entry metal-binding site (MBS) on CopA also gives rise to a Cu-sensitivity phenotype. These findings suggest that CupA and CopA may interact and filling of the CupA S2 site with Cu(i) results in stimulation of cellular copper efflux by CopA.

  17. Femoro-acetabular impingement: can indirect MR arthrography be considered a valid method to detect endoarticular damage? A preliminary study.

    PubMed

    Pozzi, Grazia; Stradiotti, Paola; Parra, Cleber Garcia; Zagra, Luigi; Sironi, Sandro; Zerbi, Alberto

    2009-01-01

    To assess the effectiveness of indirect Magnetic Resonance arthrography (i-MRa) in the detection of chondral and labral lesions related to femoro-acetabular impingement (FAI) a series of 21 hip joints in 17 patients with a clinical diagnosis of FAI were examined either with standard MR imaging, i-MRa and direct-MR arthrography (d-MRa). Sensitivity and accuracy of i-MRa in detecting chondral, labral and tardive lesions were calculated and compared with standard MR. The agreement in detecting endoarticular damage between i-MRa and d-MRa and the interobserver agreement was assessed by K statistic (p<0.05). Finally the presence of trocanteric bursitis was evaluated. I-MRa showed higher values of both sensivity and accuracy than standard MR in detecting chondral damage, with an increase to 92% for the first item and 95% for the second. The same was noticed in labrum evaluation with an increase to 88% and 90% respectively. The level of agreement between i-MRa and d-MRa in detection of chondral lesions was excellent, substantial for the labral damage and absolute for early osteoarthritic changes. An excellent interobserver agreement resulted in detection of both chondral and labral damages with i-MRa. In 6 hips (28,5%) we also found the presence of peri-trochanteric soft tissue inflammation that indicated the possibility of extrarticular involvement in FAI. Indirect-MRa can be considered a valid method of assessing endoarticular damage related to FAI, in comparison to d-MRa. It should be performed instead of standard MR if d-MRa is not available.

  18. The effects of ball possession status on physical and technical indicators during the 2014 FIFA World Cup Finals.

    PubMed

    da Mota, Gustavo Ribeiro; Thiengo, Carlos Rogério; Gimenes, Samuel Valencia; Bradley, Paul S

    2016-01-01

    This study examined the effect of high- (HPBPT) and low-percentage ball possession (LPBPT) on physical and technical indicators during 2014 FIFA World Cup matches. This would enable a regression model to be constructed to further understand the impact of different ball possession (BP) strategies on match performance. Data were collected from 346 international soccer players using a multiple-camera computerised tracking system. Although players in HPBPT covered lower distances (P < 0.01) in total and at low speed compared to LPBPT, this produced a trivial effect size (ES). However, they covered similar distances (P > 0.05) at medium and high speeds. Players in LPBPT covered more distance without BP but less with BP than HPBPT (P < 0.01; ES large). All positions in LPBPT spent less time in the opposing half and attacking third than the players in HPBPT (P < 0.01; ES small-moderate), but all positions in HPBPT completed more short and medium passes than LPBPT (P < 0.01; ES moderate). Players in HPBPT produced more solo runs into the attacking third and penalty area than LPBPT (P < 0.05, ES small). The equation to predict BP from physical and technical indicators highlighted the importance of distances covered (total, with and without BP), time spent in the attacking third and successful short passes during matches. In practical terms, high or low BP does not influence the activity patterns of international matches although HPBPT spend more time in offensive areas of the pitch.

  19. The Cup Anemometer, a Fundamental Meteorological Instrument for the Wind Energy Industry. Research at the IDR/UPM Institute

    PubMed Central

    Pindado, Santiago; Cubas, Javier; Sorribes-Palmer, Félix

    2014-01-01

    The results of several research campaigns investigating cup anemometer performance carried out since 2008 at the IDR/UPM Institute are included in the present paper. Several analysis of large series of calibrations were done by studying the effect of the rotor's geometry, climatic conditions during calibration, and anemometers' ageing. More specific testing campaigns were done regarding the cup anemometer rotor aerodynamics, and the anemometer signals. The effect of the rotor's geometry on the cup anemometer transfer function has been investigated experimentally and analytically. The analysis of the anemometer's output signal as a way of monitoring the anemometer status is revealed as a promising procedure for detecting anomalies. PMID:25397921

  20. The cup anemometer, a fundamental meteorological instrument for the wind energy industry. Research at the IDR/UPM Institute.

    PubMed

    Pindado, Santiago; Cubas, Javier; Sorribes-Palmer, Félix

    2014-11-12

    The results of several research campaigns investigating cup anemometer performance carried out since 2008 at the IDR/UPM Institute are included in the present paper. Several analysis of large series of calibrations were done by studying the effect of the rotor's geometry, climatic conditions during calibration, and anemometers' ageing. More specific testing campaigns were done regarding the cup anemometer rotor aerodynamics, and the anemometer signals. The effect of the rotor's geometry on the cup anemometer transfer function has been investigated experimentally and analytically. The analysis of the anemometer's output signal as a way of monitoring the anemometer status is revealed as a promising procedure for detecting anomalies.

  1. Use and abuse of medication during 2014 FIFA World Cup Brazil: a retrospective survey

    PubMed Central

    Vaso, Martin; Weber, Alexis; Tscholl, Philippe M; Junge, Astrid; Dvorak, Jiri

    2015-01-01

    Objective To examine the use of medication of top-level male players during the 2014 FIFA World Cup Brazil. Design Retrospective survey. Participants/information 736 top level players. Setting The teams’ physicians disclosed a list of the medications used by each player within 72 h before each match of the 2014 FIFA World Cup Brazil. Outcome measures Average number of medications used per player per match or during the tournament; average number and percentage of players using at least one medication per match or during the tournament. Results 67.0% of all players took various types of medication during the tournament. The most used medications during the tournament were non-steroidal anti-inflammatory drugs (NSAIDs), by 54.2% of all players, followed by analgaesics (12.6%); β-2 agonists were only used by 0.5%. On average, 0.8 medications per player were used before each match. More players were reported taking medications during the knockout round than during the qualification round (0.36±0.48 vs 0.49±0.50, p<0.001). Players from the South American and Asian Confederations took twice as many medications per match as players from the African Confederation (1.17±1.55 and 1.01±1.26 vs 0.48±0.69, both p<0.001). Conclusions There was high use of NSAIDs during the 2014 FIFA World Cup. Although the intake of NSAIDs per match (0.35±0.46 vs 0.31±0.48, p<0.01) in the 2014 FIFA World Cup decreased compared to the 2010 FIFA World Cup, the average use was still higher than in the 2006 FIFA World Cup, and the average number of all used medications per player remained the same level as 4 years prior, with all its implications for the player's health. More efforts need to be undertaken worldwide in order to reduce the administration of medications in sports, through continuous education for players, starting from a young age, as well as for doctors and paramedics. PMID:26359283

  2. [The assessment of changes in radiological parameters of acetabulum of the hip joint according to position of the pelvis].

    PubMed

    Adamczyk, Emil; Sibiński, Marcin; Sobala, Wojciech; Synder, Marek

    2011-01-01

    The aim of the study was to analyze the repeatability of selected radiological parameters in the assessment of mild forms of developmental dysplasia of the hip and to evaluate the changes of the parameters according the position of the pelvis. Retrospective review of radiographs of 98 hips (49 children) was done in antero-posterior and Lauenstein position. Among them 59 hips were treated for type II hip dysplasia according to Graf. At the latest follow-upthe mean age was 9.1 years (range from 4 to 15 years). On radiographs in antero-posterior position of the hips mean rotation index (Tönnis-Brunken index) was 1.0, and on radiographs in Lange position was 0.98 and had no influence on measured parameters. On radiographs in antero-posterior position pelvis was more in forward rotation than in Lange position. With the pelvis in more forward rotation (measured using Ball-Kommend index) the value of Lequesne and Ullmanna-Sharp angles were decreased and Wiberg angle was increased. The angles had good repeatability. The other parameters: acetabular index, decentration distance and Idelberg-Frank angle were not statistically related to Ball-Kommend index. Idelberg-Frank angle had satisfactory repeatability but acetabular index and decentration distance had poor repeatability. Considering above mentioned characteristics of Idelberg-Frank angle, this parameter may be a useful tool for assessment of the hip.

  3. Measuring splash erosion potential under vegetation using sand-filled splash cups

    NASA Astrophysics Data System (ADS)

    Geißler, C.; Scholten, T.; Kühn, P.

    2009-04-01

    In soil erosion research it is widely accepted that vegetation is not only protecting the soil from the erosive power of rainfall. Under specific circumstances (like they occur e.g. in forests) vegetation can enhance the erosive power of rainfall by modifying its properties (esp. drop size distribution, kinetic energy). The adjacent processes are very complex and variable in time and space and depend on numerous variables (e.g. rainfall intensity, drop size distribution, drop fall velocity, height of the canopy, density of the canopy, crown and leaf traits, LAI). In the last decades a large number of studies focused this process-system using different methods and came to often different results (Brandt 1989; Calder 2001; Foot & Morgan 2005; Hall & Calder 1993; Mosley 1982; Nanko et al. 2006; Park & Cameron 2008; Vis 1986). The main objective of our field experiments in subtropical China is to quantify the modification of precipitation by its pass through the canopy layer for six different tree species, three different successional stages and three different biodiversity classes. For this, new splash cups were developed based on the archetype of Ellison (1947). In contrast to previous studies with splash cups (Vis 1986) or other forms of splash cups (Kinnell 1974; Morgan 1981) we measured the unit sand remaining inside the cup after single natural rainfall events. The new splash cups contain of a PE-flask to which a carrier system has been attached. In this carrier system a cup filled with unit sand of 125-200 µm particle size is inserted. At the bottom of the cup a silk cover is attached to avoid the loss of sand and to guarantee free drainage of water from the cup to the carrier and vice versa. Cup and PE-flask are hydraulically connected by a cotton wick to assure constant moisture content throughout the time of measuring. Additionally, vents in the carrier system ensure that the pressure arising from the insertion of the cup doesn't lead to a loss of sand. The

  4. Influence of cup stacking on hand-eye coordination and reaction time of second-grade students.

    PubMed

    Udermann, Brian E; Murray, Steven R; Mayer, John M; Sagendorf, Kenneth

    2004-04-01

    Cup stacking has been adopted recently by many physical education programs to enhance rudimentary motor skills such as hand-eye coordination and ambidexterity as well as quickness and concentration; however, no empirical evidence has been published to support these claims. We examined the influence of cup stacking on hand-eye coordination and reaction time of 24 boys and 18 girls in second grade as measured by the Soda Pop and Yardstick tests, respectively. Two physical education classes were randomly assigned as treatment and control groups and were pre- and posttested for hand-eye coordination and reaction time. The treatment group participated in a 5-wk. cup-stacking program. Significant improvements were noted for both hand-eye coordination and reaction time between the pre- and posttest scores for this group but not for the control group. Therefore, cup stacking is indeed effective in enhancing hand-eye coordination and reaction time.

  5. A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components.

    PubMed

    Langlois, J; Atlan, F; Scemama, C; Courpied, J P; Hamadouche, M

    2015-11-01

    Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component. We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components. A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed. After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (sd 0.108): in the annealed group it was 0.1382 mm/year (sd 0.129) (Mann-Whitney U test, p < 0.001). No complication specific to either material was recorded. These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component.

  6. III-nitride tunable cup-cavities supporting quasi whispering gallery modes from ultraviolet to infrared

    PubMed Central

    Shubina, T. V.; Pozina, G.; Jmerik, V. N.; Davydov, V. Yu.; Hemmingsson, C.; Andrianov, A. V.; Kazanov, D. R.; Ivanov, S. V.

    2015-01-01

    Rapidly developing nanophotonics needs microresonators for different spectral ranges, formed by chip-compatible technologies. In addition, the tunable ones are much in demand. Here, we present site-controlled III-nitride monocrystal cup-cavities grown by molecular beam epitaxy. The cup-cavities can operate from ultraviolet to near-infrared, supporting quasi whispering gallery modes up to room temperature. Besides, their energies are identical in large ’ripened’ crystals. In these cavities, the refractive index variation near an absorption edge causes the remarkable effect of mode switching, which is accompanied by the spatial redistribution of electric field intensity with concentration of light into a subwavelength volume. Our results shed light on the mode behavior in semiconductor cavities and open the way for single-growth-run manufacturing the devices comprising an active region and a cavity with tunable mode frequencies. PMID:26656267

  7. Electronic nose for quality control of Colombian coffee through the detection of defects in "Cup Tests".

    PubMed

    Rodríguez, Juan; Durán, Cristhian; Reyes, Adriana

    2010-01-01

    Electronic noses (ENs), are used for many applications, but we must emphasize the importance of their application to foodstuffs like coffee. This paper presents a research study about the analysis of Colombian coffee samples for the detection and classification of defects (i.e., using "Cup Tests"), which was conducted at the Almacafé quality control laboratory in Cúcuta, Colombia. The results obtained show that the application of an electronic nose called "A-NOSE", may be used in the coffee industry for the cupping tests. The results show that e-nose technology can be a useful tool for quality control to evaluate the excellence of the Colombian coffee produced by National Federation of Coffee Growers.

  8. Linear Time-Invariant Compensation of Cup Anemometer and Vane Inertia

    NASA Astrophysics Data System (ADS)

    Hristov, Tihomir S.; Miller, Scott D.; Friehe, Carl A.

    We propose a method to compensate for the phase lag and the amplitudeattenuation in the cup anemometer signal. These two effects, caused by theinstrument's inertia, are the major flaws of the cup anemometer in additionto over-speeding. Since the instrument's response is invariant in wavenumber (not frequency) representation, we transform the signals to becompensated from the time domain to the spatial domain by using Taylor'shypothesis. In the spatial domain we apply a linear time-invariant filterto eliminate the phase lag and the amplitude attenuation. The proposedprocedure improves instrument performance down to spatial scales equal toor smaller than the distance constant of the anemometer. The method for cupanemometer compensation is presented in detail and later adapted for vanes.

  9. Potentiality of Eisenia fetida to degrade disposable paper cups-an ecofriendly solution to solid waste pollution.

    PubMed

    Arumugam, Karthika; Ganesan, Seethadevi; Muthunarayanan, Vasanthy; Vivek, Swabna; Sugumar, Susila; Munusamy, Vivekanadhan

    2015-02-01

    The aim of the present study was to subject the post-consumer waste, namely paper cups for vermicomposting along with cow dung in three different ratios for a period of 90-140 days employing Eisenia fetida. The post-consumer wastes are a menace in many developing countries including India. This waste was provided as feed for earthworms and was converted to vermicompost. Vermicompost prepared with paper cup waste was analyzed for their physicochemical properties. Based on the physicochemical properties, it was evident that the best manure is obtained from type A (paper cup/cow dung in the ratio 1:1) than type B (paper cup/cow dung in the ratio 1.5:0.5) and type C (paper cup/cow dung in the ratio 0.5:1.5). The results showed that earthworms accelerated the rate of mineralization and converted the wastes into compost with needed elements which could support the growth of crop plants. The predominant bacterial strains in the vermicompost were characterized biochemically as well as by 16S ribosomal RNA (rRNA) gene sequencing. The bacterial strains like Bacillus anthracis (KM289159), Bacillus endophyticus (KM289167), Bacillus funiculus (KM289165), Virigibacillius chiquenigi (KM289163), Bacillus thuringiensis (KM289164), Bacillus cereus (KM289160), Bacillus toyonensis (KM289161), Acinetobacter baumanni (KM289162), and Lactobacillus pantheries (KM289166) were isolated and identified from the final compost. The total protein content of E. fetida involved in vermicomposting was extracted, and the banding pattern was analyzed. During final stages of vermicomposting, it was observed that the earthworm did not act on the plastic material coated inside the paper cups and stagnated it around the rim of the tub. Further, the degradation of paper cup waste was confirmed by Fourier transform infrared spectroscopy analysis. Hence, vermicomposting was found to be an effective technology for the conversion of the paper cup waste material into a nutrient-rich manure, a value

  10. Nqrs Data for C26H35Br2CuP2 (Subst. No. 1603)

    NASA Astrophysics Data System (ADS)

    Chihara, H.; Nakamura, N.

    This document is part of Subvolume B 'Substances Containing C10H16 … Zn' of Volume 48 'Nuclear Quadrupole Resonance Spectroscopy Data' of Landolt-Börnstein - Group III 'Condensed Matter'. It contains an extract of Section '3.2 Data tables' of the Chapter '3 Nuclear quadrupole resonance data' providing the NQRS data for C26H35Br2CuP2 (Subst. No. 1603)

  11. Compressed ultrafast photography (CUP): redefining the limit of passive ultrafast imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Gao, Liang S.

    2016-03-01

    Video recording of ultrafast phenomena using a detector array based on the CCD or CMOS technologies is fundamentally limited by the sensor's on-chip storage and data transfer speed. To get around this problem, the most practical approach is to utilize a streak camera. However, the resultant image is normally one dimensional—only a line of the scene can be seen at a time. Acquiring a two-dimensional image thus requires mechanical scanning across the entire field of view. This requirement poses severe restrictions on the applicable scenes because the event itself must be repetitive. To overcome these limitations, we have developed a new computational ultrafast imaging method, referred to as compressed ultrafast photography (CUP), which can capture two-dimensional dynamic scenes at up to 100 billion frames per second. Based on the concept of compressed sensing, CUP works by encoding the input scene with a random binary pattern in the spatial domain, followed by shearing the resultant image in a streak camera with a fully-opened entrance slit. The image reconstruction is the solution of the inverse problem of above processes. Given sparsity in the spatiotemporal domain, the original event datacube can be reasonably estimated by employing a two-step iterative shrinkage/thresholding algorithm. To demonstrate CUP, we imaged light reflection, refraction, and racing in two different media (air and resin). Our technique, for the first time, enables video recording of photon propagation at a temporal resolution down to tens of picoseconds. Moreover, to further expand CUP's functionality, we added a color separation unit to the system, thereby allowing simultaneous acquisition of a four-dimensional datacube (x,y,t,λ), where λ is wavelength, within a single camera snapshot.

  12. Evaluation of the effect of laser acupuncture and cupping with ryodoraku and visual analog scale on low back pain.

    PubMed

    Lin, Mu-Lien; Wu, Hung-Chien; Hsieh, Ya-Hui; Su, Chuan-Tsung; Shih, Yong-Sheng; Lin, Chii-Wann; Wu, Jih-Huah

    2012-01-01

    The purpose of this study was to evaluate the effect of laser acupuncture (LA) and soft cupping on low back pain. In this study, the subjects were randomly assigned to two groups: active group (real LA and soft cupping) and placebo group (sham laser and soft cupping). Visual analog scale (VAS) and Ryodoraku were used to evaluate the effect of treatment on low back pain in this trial. Laser, 40 mW, wavelength 808 nm, pulse rate 20 Hz, was used to irradiate Weizhong (BL40) and Ashi acupoints for 10 minutes. And the Ryodoraku values were measured 2 times, that is, before and 15 minutes after treatment. The results show that there were significant difference between the first day baseline and the fifth day treatment in VAS in the two groups. Therefore, LA combined with soft cupping or only soft cupping was effective on low back pain. However, the Ryodoraku values of Bladder Meridian of the placebo group have been decreased apparently, and didn't come back to their original values. It means that "cupping" plays the role of "leak or purge" in traditional Chinese medicine (TCM). On the other hand, the Ryodoraku values of Bladder Meridian of the active group have been turned back to almost their original values; "mend or reinforcing" effect is attributed to the laser radiation.

  13. Developing a trend prediction model of subsurface damage for fixed-abrasive grinding of optics by cup wheels.

    PubMed

    Dong, Zhichao; Cheng, Haobo

    2016-11-10

    Fixed-abrasive grinding by cup wheels plays an important role in the production of precision optics. During cup wheel grinding, we strive for a large removal rate while maintaining fine integrity on the surface and subsurface layers (academically recognized as surface roughness and subsurface damage, respectively). This study develops a theoretical model used to predict the trend of subsurface damage of optics (with respect to various grinding parameters) in fixed-abrasive grinding by cup wheels. It is derived from the maximum undeformed chip thickness model, and it successfully correlates the pivotal parameters of cup wheel grinding with the subsurface damage depth. The efficiency of this model is then demonstrated by a set of experiments performed on a cup wheel grinding machine. In these experiments, the characteristics of subsurface damage are inspected by a wedge-polishing plus microscopic inspection method, revealing that the subsurface damage induced in cup wheel grinding is composed of craterlike morphologies and slender cracks, with depth ranging from ∼6.2 to ∼13.2  μm under the specified grinding parameters. With the help of the proposed model, an optimized grinding strategy is suggested for realizing fine subsurface integrity as well as high removal rate, which can alleviate the workload of subsequent lapping and polishing.

  14. Polymeric Cups for Cavitation-mediated Delivery of Oncolytic Vaccinia Virus

    PubMed Central

    Myers, Rachel; Coviello, Christian; Erbs, Philippe; Foloppe, Johann; Rowe, Cliff; Kwan, James; Crake, Calum; Finn, Seán; Jackson, Edward; Balloul, Jean-Marc; Story, Colin; Coussios, Constantin; Carlisle, Robert

    2016-01-01

    Oncolytic viruses (OV) could become the most powerful and selective cancer therapies. However, the limited transport of OV into and throughout tumors following intravenous injection means their clinical administration is often restricted to direct intratumoral dosing. Application of physical stimuli, such as focused ultrasound, offers a means of achieving enhanced mass transport. In particular, shockwaves and microstreaming resulting from the instigation of an ultrasound-induced event known as inertial cavitation can propel OV hundreds of microns. We have recently developed a polymeric cup formulation which, when delivered intravenously, provides the nuclei for instigation of sustained inertial cavitation events within tumors. Here we report that exposure of tumors to focused ultrasound after intravenous coinjection of cups and oncolytic vaccinia virus , leads to substantial and significant increases in activity. When cavitation was instigated within SKOV-3 or HepG2 xenografts, reporter gene expression from vaccinia virus was enhanced 1,000-fold (P < 0.0001) or 10,000-fold (P < 0.001), respectively. Similar increases in the number of vaccinia virus genomes recovered from tumors were also observed. In survival studies, the application of cup mediated cavitation to a vaccinia virus expressing a prodrug converting enzyme provided significant (P < 0.05) retardation of tumor growth. This technology could improve the clinical utility of all biological therapeutics including OV. PMID:27375160

  15. Testing the Solar Probe Cup, an Instrument Designed to Touch the Sun

    NASA Technical Reports Server (NTRS)

    Whittlesey, Phyllis L.; Case, Anthony W.; Kasper, Justin Christophe; Wright, Kenneth H., Jr.; Alterman, Ben; Cirtain, Jonathan W.; Bookbinder, Jay; Korreck, Kelly E.; Stevens, Michael Louis

    2014-01-01

    Solar Probe Plus will be the first, fastest, and closest mission to the sun, providing the first direct sampling of the sub-Alfvenic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

  16. Testing the Solar Probe Cup, An Instrument Designed to Touch The Sun

    NASA Technical Reports Server (NTRS)

    Whittlesey, Phyllis; Case, Anthony; Kasper, Justin; Wright, Kenneth; Alterman, Benjamin; Cirtain, Jonathan; Bookbinder, Jay; Korreck, Kelly; Stevens, Michael; Schneider, Todd; Vaughn, Jason

    2014-01-01

    Abstract: Solar Probe Plus will be the first, fastest, and closest mission to the Sun, providing the first direct sampling of the sub-Alfvénic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests are created for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight-like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

  17. Selected current-use pesticides (CUPs) in coastal and offshore sediments of Bohai and Yellow seas.

    PubMed

    Zhong, Guangcai; Tang, Jianhui; Xie, Zhiyong; Mi, Wenying; Chen, Yingjun; Möller, Axel; Sturm, Renate; Zhang, Gan; Ebinghaus, Ralf

    2015-02-01

    China is one of the largest producers, consumers, and traders for pesticides in the world. Currently, there are more than 600 pesticide-active substances registered in China, whereas few studies were conducted to improve our understanding of the occurrence and environmental impact of current-use pesticides (CUPs) in China's environment. In this work, 72 surface sediment samples were taken from the coastal and offshore of Bohai and Yellow seas and were analyzed for six CUPs (trifluralin, dacthal, quintozene, endosulfan, chlorpyrifos, and dicofol) and two metabolites (pentachloroanisole and endosulfan sulfate). Sediment samples were categorized as estuarine or near-shore sediments (Laizhou Bay, Taozi Bay, Sishili Bay, and Jiaozhou Bay) and offshore sediments. Trifluralin, α-endosulfan, endosulfan sulfate, chlorpyrifos, dicofol, and pentachloroanisole were detected in more than 60 % of the samples. Dicofol was the predominant compound with concentrations mostly higher than 100 pg/g dry weight (dw) with the highest concentration of 18,000 pg/g dw. Concentrations of other compounds were mainly below 100 pg/g dw. CUP levels were much lower than the sediment screening benchmark calculated. The highest levels of α-endosulfan, endosulfan sulfate, trifluralin, and chlorpyrifos existed at Laizhou Bay, whereas pentachloroanisole and dicofol had highest mean concentrations at Jiaozhou Bay. Generally, no correlation between pesticide concentrations and total organic carbon was observed either for offshore samples or for near-shore samples.

  18. Comparison of Obstetric Efficacy and Safety of the Kiwi OmniCup with Conventional Vacuum Extraction.

    PubMed

    Siggelkow, W; Schwarz, N; Beckmann, M W; Kehl, S; Faschingbauer, F; Schild, R L

    2014-02-01

    Purpose: The aim of the present study was to compare the safety and efficacy of the Kiwi OmniCup system with conventional vacuum delivery. Methods: A retrospective study of operative vaginal deliveries was done for 4682 births. The procedures included 217 operative vaginal deliveries (4.6 %), 79 of which were done using conventional vacuum extraction (37 %) and 138 using the Kiwi system (63 %). Results: Use of the Kiwi system was associated with a significant reduction in episiotomies (61 vs. 76 % in the control group; p < 0.05). The rates of successful completion of birth were comparable for the two systems (94 % with the Kiwi system and 99 % with conventional vacuum delivery). Cup detachment occurred significantly more often in the Kiwi group (p < 0.005), requiring a change to a different method of birth significantly more often. It was necessary to change the procedure significantly more often from the mid-pelvis (p < 0.05). The incidence of maternal and foetal injuries was similar for the two systems. Conclusions: With regard to obstetric efficacy and safety and foetal and maternal injuries, the Kiwi system is an acceptable alternative to the conventional vacuum cup. The advantages of the Kiwi system are its significantly lower episiotomy rate and its ease and rapidity of use.

  19. Behavior of CuP and OFHC Cu anodes under electrodeposition conditions

    SciTech Connect

    Frankel, G.S.; Schrott, A.G.; Horkans, J.; Andricacos, P.C. . Thomas J. Watson Research Center); Isaacs, H.S. )

    1992-01-01

    Films formed on CuP (with 0.05 wt % P) and OFHC Cu anodes in electroplating solutions were studied by X-ray Photoelectron Spectroscopy, X-ray Absorption Spectroscopy, electrochemical methods, and a newly developed gravimetric technique. The black film formed on CuP in Cl-containing solutions was found to resemble a porous sponge composed of CuCl but laden/with concentrated CuSO{sub 4} solution. The difference between the buoyancy-corrected measured mass change and the charge-equivalent mass change was found to have two components: a reversible part that comes and goes as the current is turned on and off, and an irreversible part that remains on the surface and increase in mass with time. The irreversible part results from the anodic film, which increases linearly with charge density but independent of current density. The reversible part of the mass change arises from the weight of the diffusion layer. In contrast to CuP, OFHC Cu releases much more Cu{sup +1} during anodic polarization and forms a poorly-adherent anodic film that is considerably heavier than the black film for a given charge density.

  20. Behavior of CuP and OFHC Cu anodes under electrodeposition conditions

    SciTech Connect

    Frankel, G.S.; Schrott, A.G.; Horkans, J.; Andricacos, P.C.; Isaacs, H.S.

    1992-08-01

    Films formed on CuP (with 0.05 wt % P) and OFHC Cu anodes in electroplating solutions were studied by X-ray Photoelectron Spectroscopy, X-ray Absorption Spectroscopy, electrochemical methods, and a newly developed gravimetric technique. The black film formed on CuP in Cl-containing solutions was found to resemble a porous sponge composed of CuCl but laden/with concentrated CuSO{sub 4} solution. The difference between the buoyancy-corrected measured mass change and the charge-equivalent mass change was found to have two components: a reversible part that comes and goes as the current is turned on and off, and an irreversible part that remains on the surface and increase in mass with time. The irreversible part results from the anodic film, which increases linearly with charge density but independent of current density. The reversible part of the mass change arises from the weight of the diffusion layer. In contrast to CuP, OFHC Cu releases much more Cu{sup +1} during anodic polarization and forms a poorly-adherent anodic film that is considerably heavier than the black film for a given charge density.