  1. The Divergence of Wear Propagation and Stress at Steep Acetabular Cup Positions Using Ceramic Heads and Sequentially Cross-Linked Polyethylene Liners.

    PubMed

    Zietz, Carmen; Fabry, Christian; Baum, Felix; Bader, Rainer; Kluess, Daniel

    2015-08-01

    The aim of the present wear simulator study was to assess the effect of steep acetabular cup positions on the wear propagation of highly cross-linked-PE (HX-PE) liners. Furthermore, a finite element analysis (FEA) was performed in order to calculate the stress within the HX-PE material in case of steep cup positions under physiological loadings. The higher stress in the HX-PE at a steep acetabular cup position did not result in increased wear in the present wear simulator study. The gravimetrical wear rates at normal (45°) and steep cup inclinations (75°) showed wear amounts of 3.15±0.27mg and 2.18±0.31mg per million cycles (p=0.028), respectively. However, FEA revealed clear increase in stress at the HX-PE liners with respect to steep cup positions. PMID:25770865

  2. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups.

    PubMed

    Smith, S L; Ash, H E; Unsworth, A

    2000-01-01

    A novel design of polyurethane compliant layer acetabular cup has been developed through a series of friction, creep and wear tests. Friction tests were initially conducted on ABG standard form, polyurethane acetabular cups and an ABG standard form, UHMWPE acetabular cup for comparison. The polyurethane cups showed lower friction than the UHMWPE cup with maximum friction factors between 0. 008 and 0.02 compared with 0.035 for the UHMWPE cup. This indicated that, in the polyurethane cups, more of the load across the joint was carried by the fluid entrapped in the joint space rather than with asperity contact, compared with the UHMWPE cup. The inherent compliance of the polyurethane is used to promote elasto-hydrodynamic lubrication. However, this compliance raised concerns over excessive creep, which may in turn adversely affect tribological performance. Therefore, creep tests were undertaken on the ABG standard form, polyurethane acetabular cups followed by further friction tests. Small amounts of creep occurred in the polyurethane cups at ambient temperature, which reduced the friction slightly (maximum friction factors of 0.009) due to increased conformity between the head and the cup. However, at 37 degrees C, greater creep occurred causing pinching of the femoral head by the acetabular cup resulting in lubricant starvation and higher friction (maximum friction factors of 0.035). The design of the polyurethane cups was subsequently modified to incorporate a flared rim to eliminate the possibility of fluid starvation through pinching. Creep in polyurethane acetabular cups is also affected by the method of fixation of the cups, due to the conformity with and the stiffness of the cup backing. Hence, a one-million-cycle wear test was performed on five ABG flared form, polyurethane acetabular cups on the Mk. I Durham Hip Joint Wear Simulator to evaluate the best method of fixation for the polyurethane cups. The smallest amount of penetration, due to creep and wear

  3. Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology.

    PubMed

    Peters, Frank M; Greeff, Richard; Goldstein, Neal; Frey, Chris T

    2012-08-01

    Acetabular cup placement in total hip arthroplasty is often difficult to assess, especially in the lateral position and using the posterior approach. Conventional techniques and computer-assisted surgery are the 2 most popular methods for proper placement of the acetabular cup in Lewinnek's safe zone of orientation (anteversion 15° ± 10° and lateral inclination 40° ± 10°). We developed a system that uses the accelerometer and camera function of the iPhone. A level indicator application and protractor application were downloaded to the iPhone and used to improve acetabular cup placement. This system has proven to be accurate and quick. Our series of 50 prospective cases showed good results with all our acetabular cups being placed within a narrow range in the safe zone and with less than 5% difference between the preoperative, intraoperative, and postoperative acetabular inclinations. PMID:22245126

  4. Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement

    PubMed Central

    Li, Junwei; Gao, Xu; Yang, Guanghui; Zhang, Yanru

    2015-01-01

    Positions of acetabular implant generally are considered to be major causative factors of dislocation. Accurate and consistent achievement of the preoperatively anticipated orientation of the acetabular cup is a great challenge in total hip replacement (THR). In the present study, we investigated the surgical application of acetabular fossa as a guide for anticipated inclination of uncemented cup, and evaluated its accuracy as an anatomic reference for achieving the preoperatively anticipated abduction of the acetabular cup in comparison with traditional device method on cadaveric specimens. Sixteen normal adult pelvic cadaveric specimens were collected. On each of the sixteen normal adult pelvic cadaveric specimens, acetabular fossa related anatomic sites were marked and studied on pelvic radiographs. Our results showed that there is close correlation between most medial aspect of acetabular sourcil and central axis of the acetabular cup at anticipated inclination of 40° ± 5°. And the fossa group can achieve the preoperatively anticipated cup abduction more accurately than the device group. The current results demonstrated that acetabular fossa can be a reasonable alternative, or as a complement to the currently used methods guiding total hip replacement. PMID:25784987

  5. Profile Measurement of Worn Acetabular Cup by Holographic Contouring

    NASA Astrophysics Data System (ADS)

    Kakunai, Satoshi; Sakamoto, Tohoru; Sakurai, Daisuke; Aota, Yuuki; Shelton, Julia

    Wear in a polyethylene acetabular cup is dependent on the history of the cup, namely on the sterilization treatment, initial mounting situation, the patient's lifestyle and length of time in vivo. Understanding wear patterns is essential in order to prevent inflammation and prosthesis failure. This study describes the profile measurement of a worn acetabular cup by holographic contouring, which can provide non-contact measurement over the entire visual field. Experiments were performed to verify the method, and measurements of cups worn in vivo were carried out. Cup profile was investigated using holograms obtained in three directions and changes in cup profile were evaluated using fringe patterns in which the interval range was adjusted from tens of microns to several millimeters.

  6. Dissociation of a polyethylene liner from an acetabular cup.

    PubMed

    Cameron, H U

    1993-10-01

    A polyethylene linear dissociated from a metal acetabular shell that could not be removed at the time of hip revision because the hexagonal hole in its screw head had become rounded off. A high-speed metal cutting burr was used to remove the screw and allow cup revision. PMID:8265224

  7. Research synthesis of recommended acetabular cup orientations for total hip arthroplasty.

    PubMed

    Harrison, Claire L; Thomson, Avril I; Cutts, Steven; Rowe, Philip J; Riches, Philip E

    2014-02-01

    Total hip arthroplasty (THA) is regarded as one of the most successful surgical procedures of modern times yet continues to be associated with a small but significant complication rate. Many early failures may be associated with poor component positioning with, in particular, acetabular component orientation dependent on the subjective judgement of the surgeon. In this paper, we compare the manufacturers' instructions on acetabular cup orientation with the literature-based recommended safety zones and surgical technique, by transforming them onto a single, clinically-relevant framework in which the different reference systems, safety guidelines and current instrumentation surgical techniques can be evaluated. The observed limited consensus between results reflects ongoing uncertainty regarding the optimum acetabular component positioning. As malpositioning of the acetabular cup increases the risk of revision surgery, any ambiguity over the correct position can have a causal effect. Our analysis highlights the need for a surgical reference system which can be used to describe the position of the acetabular cup intra-operatively. PMID:23958234

  8. Increased risk of revision of acetabular cups coated with hydroxyapatite

    PubMed Central

    Lazarinis, Stergios; Kärrholm, Johan

    2010-01-01

    Background Hydroxyapatite (HA) is the main inorganic component of bone, and HA coating is widely used on acetabular cups in hip arthroplasty. It has been suggested that this surface finish improves cup survival. Methods All patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2007 with an uncemented acetabular implant that was available either with or without HA coating were identified. 8,043 total hip arthroplasties (THAs) with the most common cup types (Harris-Galante, Romanus, and Trilogy) were investigated. A Cox regression model including type of coating, age, sex, primary diagnosis, cup type, and type of stem fixation was used to calculate adjusted risk ratios (RRs) for the risk of revision. Results HA coating was a risk factor for cup revision due to aseptic loosening (adjusted RR 1.7; 95% CI: 1.3–2). Age at primary arthroplasty of < 50 years, a diagnosis of pediatric hip disease, the use of a cemented stem, and the Romanus and Harris-Galante cup types were also associated with statistically significantly increased risk of cup revision due to aseptic loosening. Interpretation Our findings question the routine use of HA-coated cups in primary total hip arthroplasty. With some designs, this practice may even increase the risk of loosening—resulting in revision surgery. PMID:19968603

  9. Cross table lateral radiography for measurement of acetabular cup version

    PubMed Central

    Gunderson, Ragnhild Beate

    2016-01-01

    Background Appropriate orientation of the acetabular cup is an important factor for long-term results of total hip arthroplasty. For measurement of cup version cross-table lateral radiography is frequently used, but the reliability has been questioned. We compared cross table lateral radiography with computed tomography in patients that had undergone primary total hip arthroplasty. Methods The study was prospectively done in 117 patients (117 hips). At 3 months after total hip replacement the acetabular version was measured by cross table lateral radiography and compared to measurements by computed tomography. Results By cross table lateral radiography acetabular anteversion was on mean 13.9° with a standard deviation of 10.1° as compared to 17.8°±12.6° by computed tomography. Mean difference was −3.8 with a distribution of measurements of ±13 degrees for 95% of the cases. Conclusions Our study shows that cross table radiography provides acceptable information for clinical use, but has limited use for precise analysis of acetabular cup version. PMID:27275482

  10. Navigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty

    PubMed Central

    Yoon, Jung-Ro; Yu, Jung Jin; Seo, Hyo-Sung

    2014-01-01

    Purpose To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. Materials and Methods This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation and radiographic data to determine whether the acetabular cup was located within the safe zone or not. To evaluate the clinical outcomes, preoperative and last follow-up Harris hip scores were checked, and the occurrence of complications was evaluated. Results According to the navigation data, the mean inclination and anteversion were 38.5°±4.7°(range, 32°-50°) and 16.6°±4.0°(range, 8°-23°), respectively. According to the radiographic data the mean inclination and anteversion were 40.5°±4.6°(range, 32°-50°) and 19.4°±4.2°(range, 8°-25°), respectively. In both cases, all values were within the safe zone. Harris hip score was improved in all patients from preoperative 52.3±14.4 points (range, 29-87 points) to 88.0±9.0 points (range, 65-99 points) at the last follow-up. There was no dislocation or loosening of both cases. Conclusion Navigated acetabular cup fixation is a useful technique for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty because it prevents the malposition and related complications.

  11. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant.

    PubMed

    Bigsby, R J; Hardaker, C S; Fisher, J

    1997-01-01

    The Leeds physiological anatomical (PA) hip joint simulator was developed to apply three axes of loading and a complex three-dimensional motion so that the forces and motions can reproduce exactly the walking cycles defined by Paul. This paper presents the results of a study using the Leeds PA hip joint simulator to determine the wear of 32 mm ultra-high molecular weight polyethylene (UHMWPE) acetabular cups against stainless steel and zirconia ceramic heads, using bovine serum as lubricant. These results have been compared with the results of a previous study that used water as the lubricant, which led to UHMWPE transfer film being formed on the stainless steel head. Comparisons are also made with clinical results and results from other simulators. The study indicates that it is preferable to use bovine serum in simulator studies. In addition, the results indicate that if the surface roughness of the metallic and femoral heads are similar, and they remain undamaged during the tests, the wear rates of the UHMWPE cups are likely to be similar. PMID:9256003

  12. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  13. Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.

    PubMed

    Ellenrieder, Martin; Bader, Rainer; Bergschmidt, Philipp; Mittelmeier, Wolfram

    2016-03-01

    Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred. PMID:26984655

  14. The relationship between operative and radiographic acetabular component orientation: which factors influence resultant cup orientation?

    PubMed

    Grammatopoulos, G; Pandit, H G; da Assunção, R; McLardy-Smith, P; De Smet, K A; Gill, H S; Murray, D W

    2014-10-01

    There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph. PMID:25274911

  15. The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2016-08-01

    The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. PMID:27210567

  16. Displacement and Stress Analysis around the Artificial Acetabular Cup in a Total Hip Replacement

    NASA Astrophysics Data System (ADS)

    Kakunai, Satoshi; Tachibana, Hiroyuki; Sakamoto, Tohru; Abo, Masayoshi; Ikeda, Daisaku; Fujiwara, Hiroo

    In order to improve the service life of the artificial acetabular cup in a total hip replacement, it is important to determine the best material and design, and to assess the mechanical behavior around the cup. In this study, electronic speckle interferometry (ESPI) and the two-dimensional finite element method (FEM) are employed to investigate the mechanical behavior. The influence of the cancellous bone and cup thickness on mechanical behavior around the cup was investigated. Good agreement of the cup model was found between the ESPI measurements and FEM predictions. The following results were obtained. (1) Cancellous bone with a porous structure can be measured by the ESPI method. (2) There are discontinuities of the displacement distribution in the transverse direction in each boundary region of the cup, bone cement and cancellous bone. (3) The maximum shear stress exists in the boundary region of the cup and bone cement.

  17. A technique to remove a well-fixed titanium-coated rm acetabular cup in revision hip arthroplasty

    PubMed Central

    2011-01-01

    A major concern during revision hip arthroplasty is acetabular bone loss and bleeding during the extraction of well-fixed cementless acetabular cup, because no interface exists between the host bone and the cup. Forceful removal of such component using curved gouges and osteotomes often leads to extended bone loss and compromises reimplantation of a new socket. In the following case report, we removed a well-fixed polyethylene titanium-coated RM acetabular cup with 20 years of follow-up, by significant wear of the polyethylene layer. The isoelastic femoral stem was also removed by mechanical failure. We report a technique for removal of the cementless acetabular cup using powered acetabular reamers. The RM cup was sequentially reamed and when the polyethylene layer was thin enough, the remaining cup was removed easily by hand tools. The acetabular bone stock is preserved and the risks of bone fractures and bleeding are minimized. To our knowledge, these principles were applied only in cemented cups. We have used this technique in 10 cases with excellent results and no complications were noted. This is a simple, reproducible, non-costly, non-timing consuming, safe and successful technique to remove well-fixed titanium-coated RM acetabular cups. PMID:21689456

  18. Evaluation of acetabular cup initial fixation by using resonance frequency principle.

    PubMed

    Henys, Petr; Capek, Lukas; Fencl, Jaroslav; Prochazka, Egon

    2015-01-01

    The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of dislocation failure is highest in the first year after arthroplasty implantation. The aim of the study was to quantitatively evaluate the implant-bone stability of a cementless acetabular cup prosthesis by using a device based on resonance frequency analysis. The evaluation of this device was done by finite element analysis and in vitro experiments. It was shown that not all the resonance frequencies can be measured by our device. The resonance frequencies vary within the range of 500-3000 Hz. The proposed power spectrum measurement gives the information about the absolute stiffness of the press-fit implant. PMID:25655952

  19. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.

    PubMed

    McKellop, H; Shen, F W; DiMaio, W; Lancaster, J G

    1999-12-01

    Crosslinking of ultrahigh molecular weight polyethylene has been shown to markedly improve its wear resistance in clinical studies and laboratory tests using hip joint simulators. However, because most of the laboratory studies have been done under clean conditions using prosthesis-quality, highly polished counterfaces, there is concern regarding how well an intentionally crosslinked polyethylene acetabular cup will resist abrasion by a femoral ball that has been damaged by third-body abrasion in vivo. To investigate this, conventional and radiation crosslinked-remelted acetabular cups of ultra-high molecular weight polyethylene were tested in a hip joint simulator bearing against smooth femoral balls and against balls with moderate and severe roughening. Cups were tested with and without aging to accelerate any oxidative degradation. The crosslinked cups were produced by exposing extruded GUR 4150 bar stock of ultrahigh molecular weight polyethylene to 5 Mrad gamma radiation under a partial vacuum and then the bars were remelted to extinguish residual free radicals. Artificial aging at 70 degrees C under 5 atm oxygen for 14 days induced negligible oxidation in the crosslinked and remelted material. Against smooth balls, the wear of the crosslinked cups, with or without aging, averaged approximately 15% of that of the conventional cups. Against the moderately rough balls, the wear rate of the conventional cups was unchanged, whereas the wear rate increased slightly for the nonaged and aged crosslinked cups, but was still only 26% and 20% of that of the conventional cups, respectively. Against extremely rough balls, the mean wear rates increased markedly for each material such that during the final 1 million cycle interval, the average wear rates of the nonaged and the aged crosslinked cups were 72% and 47% of that of the conventional cups, respectively. That is, the crosslinked polyethylene showed substantially better wear resistance than conventional polyethylene

  20. Acute polyethylene fracture in an uncemented acetabular cup

    PubMed Central

    Gross, Allan E.; Dust, William N.

    1997-01-01

    The smaller acetabular components used in total hip replacement may have a polyethylene liner that is too thin, resulting in higher polyethylene stress and an increased potential for wear. The authors present a case that highlights the problem of acute polyethylene fracture. To compensate for the thinness of the polyethylene, the authors recommend the use of a smaller head size to allow polyethylene thickness of at least 8 mm. PMID:9267302

  1. Vibrational spectroscopy study of the oxidation of Hylamer UHMWPE explanted acetabular cups sterilized differently

    NASA Astrophysics Data System (ADS)

    Reggiani, Matteo; Tinti, Anna; Visentin, Manuela; Stea, Susanna; Erani, Paolo; Fagnano, Concezio

    2007-05-01

    Ultra-high-molecular-weight polyethylene (UHMWPE) has been used for over 40 years for acetabular cups in total hip joint prosthesis. Hylamer is a hot isostatically pressed material with high crystallinity. Early loosening due to extensive oxidation and phase transformation has been observed for this material. To analyze the reasons for its high tendency to oxidize, we have examined by FT-IR spectroscopy explanted acetabular cups γ-sterilized in different ways. The oxidation and wear rate observed were: Hylamer cups γ-sterilized in air with a long shelf life > Hylamer cups γ-sterilized in air with short shelf life ⩾ Hylamer cups γ-sterilized in nitrogen. Our data indicate the important role of the shelf life on the oxidation of the cups: the samples γ-sterilized in air characterized by a shelf life greater than 3 years showed severe oxidation, a high wear rate, and marked debris production with delamination and the formation of a brittle zone in the more oxidated regions. In these regions we observed an increase in crystallinity, which was probably due to the decrease in the molecular weight of PE. The high oxidation was probably due to the modifications induced by the material treatment.

  2. Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability.

    PubMed

    Souffrant, R; Zietz, C; Fritsche, A; Kluess, D; Mittelmeier, W; Bader, R

    2012-01-01

    Primary stability of artificial acetabular cups, used for total hip arthroplasty, is required for the subsequent osteointegration and good long-term clinical results of the implant. Although closed-cell polymer foams represent an adequate bone substitute in experimental studies investigating primary stability, correct numerical modelling of this material depends on the parameter selection. Material parameters necessary for crushable foam plasticity behaviour were originated from numerical simulations matched with experimental tests of the polymethacrylimide raw material. Experimental primary stability tests of acetabular press-fit cups consisting of static shell assembly with consecutively pull-out and lever-out testing were subsequently simulated using finite element analysis. Identified and optimised parameters allowed the accurate numerical reproduction of the raw material tests. Correlation between experimental tests and the numerical simulation of primary implant stability depended on the value of interference fit. However, the validated material model provides the opportunity for subsequent parametric numerical studies. PMID:22817471

  3. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up)

    PubMed Central

    Livesley, Peter

    2005-01-01

    We reviewed 81 consecutive ABG I primary total hip replacements implanted in 72 patients between January 1993 and December 1998. The mean follow-up was 8.2 (range 7–12) years. There was significant polyethylene wear and osteolysis associated with the acetabular cup .The cumulative survival of the cup with revision being the end point at 8.2 years was 95.1% (95% CI: 92–97.6%). However, the cumulative survival of the cup with revision and aseptic loosening together was 72% (95% CI: 61–78%) and survival of the acetabular liner for wear was 62% (95% CI: 48–74%). Stem survival with revision being the end point was 100%. In spite of significant radiological failures of the cups, most patients remained asymptomatic. Though results of the ABG stems in this series were good, we advocate a regular follow-up of all these hips in view of the poor outcome of the cups. PMID:16283307

  4. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation.

    PubMed

    Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien

    2014-09-01

    Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. PMID:25080896

  5. Constrained captive acetabular cup for recurrent dislocation of hemiarthroplasty in elderly: A case series

    PubMed Central

    Rajeev, Aysha; Banaszkiewicz, Paul

    2016-01-01

    Introduction Hemiarthroplasty of the hip is one of the commonest procedures done for intracapsular fractures of the neck of femur in elderly. Dislocation of the hemiarthroplasty is a recognised and significant complication. This is associated with considerable morbidity and mortality. The treatment options include closed manipulation, skin and skeletal traction, conversion to total hip replacement, exploration and open reduction and leaving it out of the acetabulum. Presentation of case A retrospective review of ten patients with recurrent and failed closed manipulative reduction of hemiarthroplasty who underwent revision using a cemented captive acetabular cup and cement to cement revision of femoral component with Exeter CDH stem was carried out. The follow up period was two years and the functional outcomes were assessed using Harris hip scores. Discussion The management of recurrent dislocations of hemiarthroplasty in elderly patient are very challenging. Even though various treatment options are described most of them are associated with increased morbidity and mortality and prevent these patients from early mobilisation. The use of captive acetabular avoid repeated dislocations, prolonged bed rest, wearing of a brace and all the complications associated with sustained immobilization. The drawbacks of using constrained cups are hip pain, limited hip movements and loosening. Conclusion We describe a new method of treatment of this difficult condition with a cemented constrained acetabular captive cup and cement to cement revision using a CDH femoral stem. This method prevents further dislocations and will give good functional outcomes thus reducing the high morbidity and mortality. PMID:27129135

  6. The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation.

    PubMed

    Phillips, A T M; Pankaj; Usmani, A S; Howie, C R

    2004-01-01

    The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup. PMID:15376726

  7. Long-term Radiographic Assessment of Cemented Polyethylene Acetabular Cups

    PubMed Central

    Isaac, Graham; Porter, Neil; Fisher, John; Older, John

    2008-01-01

    In vitro studies demonstrating excessive wear in polyethylene cups sterilized using gamma irradiation and stored in air led to the abandonment of this sterilization technique. We evaluated the clinical wear performance of a metal femoral component on a polyethylene cup in a hip prosthesis from a selected subset of implants in a group of patients followed for at least 20 years and assessed the time dependency of variation in penetration rates. We measured penetration in 33 polyethylene cups in 25 patients who had a Charnley low-friction arthroplasty between 1982 and 1984. All patients had Charnley Ogee® cups implanted for more than 20 years and sterilized using the gamma irradiation in air technique. If degradation occurred over time in vivo, it was not reflected by an increased penetration rate with increasing time in vivo; even after 20 years of implantation, the degree of wear remained low. This suggests gamma irradiation affects wear on ultra-high-molecular-weight polyethylene by reducing wear secondary to the crosslinking, by increasing wear as shown through in vitro studies of heavily oxidized samples, or by oxidation resulting from prolonged shelf life. The effect of progressive oxidation in vivo does not appear to affect wear in vivo. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196419

  8. Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System.

    PubMed

    Kurosaka, Kenji; Fukunishi, Shigeo; Fukui, Tomokazu; Nishio, Shoji; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Daimon, Takashi; Yoshiya, Shinichi

    2016-07-01

    Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.]. PMID:27322169

  9. Assessment of accuracy of acetabular cup orientation in CT-free navigated total hip arthroplasty.

    PubMed

    Fukunishi, Shigeo; Fukui, Tomokazu; Imamura, Fumiaki; Nishio, Shoji

    2008-10-01

    We have used the Orthopilot (Aesculap AG, Tuttlingen, Germany) computed tomography (CT)-free navigation system to ensure accurate and reproducible acetabular cup orientation. In this system, cup orientation is assessed with respect to bony configuration as determined by palpation of the anatomical landmarks (the bilateral anterosuperior iliac spines and the upper margin of the pubic symphysis). In this study, intraoperative cup orientation as presented by the OrthoPilot navigation system was compared with the value obtained through postoperative radiological assessment using CT Digital Imaging and Communications in Medicine (DICOM) data and Medical Image Processing, Analysis, and Visualization (MIPAV; National Institutes of Health, US Department of Health and Human Services, Bethesda, Maryland). Intra- and postoperative results obtained from 27 consecutive navigated total hip arthroplasties (THAs) were analyzed. For cup positioning, the desired inclination and anteversion angles were set within the "safe zone" proposed by Lewinnek. In the intraoperative evaluation, the mean inclination angle as determined by the navigation system was 43.5 degrees +/- 2.17 degrees (range, 39.9 degrees to 46.6 degrees ) after the final implantation. In contrast, the mean inclination angle determined by postoperative calculation using MIPAV was 44.9 +/- 3.3 degrees (range, 38.1 degrees to 55.0 degrees ). A discrepancy of >5 degrees was observed in only 1 hip. For the anteversion, the mean intra- and postoperative values were 11.1 degrees +/- 5.6 degrees (range, 0 degrees to 17.8 degrees ) and 13.5 degrees +/- 5.9 degrees (range, 5.1 degrees to 21.6 degrees ), respectively. Again, a discrepancy of >5 degrees was observed in 1 case. Mean differences between the intra- and postoperative values were 1.9 degrees +/- 1.9 degrees and 2.6 degrees +/- 1.6 degrees for inclination and anteversion, respectively. A good agreement between the intraoperative values presented by the navigation system

  10. The biological approach in acetabular revision surgery: impaction bone grafting and a cemented cup.

    PubMed

    Colo, Ena; Rijnen, Wim H C; Schreurs, Berend Willem

    2015-01-01

    Acetabular impaction bone grafting (IBG) in combination with a cemented cup in revision total hip arthroplasty (THA) is a proven and well-recognised technique which has been used in clinical practice for more than 35 years. Nowadays, with cemented prostheses tending to lose a larger part of the THA market every year in primary and revision cases, and many young surgeons being only trained in implanting uncemented prostheses, this technique is considered by many as technically demanding and time consuming, making its use less appealing. Despite this image and many new innovative techniques using uncemented implants in acetabular revisions over the last 25 years, IBG with a cemented cup is still one of the few techniques that really can reconstitute bone and respects human biology. In this era of many biologically-based breakthroughs in medicine, it is hard to explain that the solution of most orthopaedic surgeons for the extensive bone defects as frequently seen during acetabular revision surgery, consists of implanting bigger and larger metal implants. This review aims to put the IBG method into a historical perspective, to describe the surgical technique and present the clinical results. PMID:26044533

  11. Expertise modeling for automated planning of acetabular cup in total hip arthroplasty using combined bone and implant statistical atlases.

    PubMed

    Otomaru, Itaru; Kobayashi, Kazuto; Okada, Toshiyuki; Nakamoto, Masahiko; Kagiyama, Yoshiyuki; Takao, Masaki; Sugano, Nobuhiko; Tada, Yukio; Sato, Yoshinobu

    2009-01-01

    Intraoperative robotic and computer-guided assistances are now commonly used in total hip arthroplasty (THA) for accurate execution of the preoperative plan. Although the preoperative plan to be accurately executed is critical, it is still interactively prepared in a time-consuming and subjective manner. In this paper, atlas-based approach to automated surgical planning of the acetabular cup in THA is described to stabilize its quality as well as reduce its time-consuming nature. Surgeon's expertise is embedded in two types of statistical atlases, which are constructed from training datasets of CT-based 3D plans prepared by experienced surgeons. One is a statistical shape model which encodes global spatial relationships between the patient anatomy and implant. The other is the statistical map of residual bone thickness on the implant surface, which encodes local spatial constraints of the anatomy and implant. Given the 3D pelvis shape of the patient, we formulate a procedure to determine the best size and position of the acetabular cup which satisfy the constraints derived from the two statistical atlases. We validated the proposed planning method by retrospective study using the datasets which were actually used in the THA surgery. PMID:20426029

  12. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    PubMed Central

    Ghanem, Mohamed; Glase, Almuth; Zajonz, Dirk; Roth, Andreas; Heyde, Christoph-E.; Josten, Christoph; von Salis-Soglio, Georg

    2016-01-01

    Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR) in multi-morbid patients. Patients and methods: During the period from January 1st 2007 to December 31st 2011 19 revision hip surgeries were performed in 19 patients, in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%). All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months). Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%. Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%). The most common complication encountered was the proximal migration of the bipolar head. The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%). Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as

  13. A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

    PubMed

    Clarke, S G; Phillips, A T M; Bull, A M J; Cobb, J P

    2012-06-01

    The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study. PMID:22513086

  14. Monitoring the press-fit insertion of an acetabular cup by impact measurements: influence of bone abrasion.

    PubMed

    Michel, Adrien; Bosc, Romain; Mathieu, Vincent; Hernigou, Philippe; Haiat, Guillaume

    2014-10-01

    Press-fit procedures used for the insertion of cementless hip prostheses aim at obtaining optimal implant primary stability. We have previously used the measurement of impact duration to follow the insertion of the acetabular cup implant within bone tissue. The aim of this study was to investigate the variation of the value of the impact momentum due to successive insertions of the acetabular cup into bone tissue. The results obtained with impact momentum and contact duration measurements were compared. A total of 10 bovine bone samples were subjected to three successive procedures consisting of 10 reproducible impacts (3.5 kg falling 40 mm). Each procedure aimed at inserting the acetabular cup implant into the same bone cavity. The time variation of force during each impact was recorded by a force sensor, allowing the measurement of the impact duration (I 1) and momentum (I 2). The value of I 2 increased as a function of the impact number and reached a constant value after N 2 = 5.07 ± 1.31 impacts. Moreover, statistical analyses show that N 2 decreased significantly as a function of the number of experiments, which may be due to abrasion phenomena at the bone-implant interface. Abrasion phenomena led to a faster insertion of the acetabular cup when the implant had been previously inserted into the same bone cavity. An empirical analytical model considering a flat punch configuration to model the bone-implant contact conditions was used to understand the trend of the variation of I 2 during the insertion of the acetabular cup. The measurement of the force during impacts is useful to assess the bone-implant interface properties, but needs to be validated in the clinic to be useful for orthopaedic surgeons intra-operatively. PMID:25258009

  15. Cup positioning in total hip arthroplasty.

    PubMed

    Scheerlinck, T

    2014-09-01

    The "optimal" positioning of the cup in total hip arthroplasty can improve hip function and reduce wear, impingement and dislocation. The cup position is described as the spatial relation between the hip rotation centre and the pelvis and, as the cup orientation around the rotation centre. The first parameter affects hip balance and, if not managed properly, might result in poor function and leg length discrepancy. The second parameter is often "silent", unless impingement or dislocation occurs. However, inappropriate cup orientation can accelerate wear and cause early failure. As such, it is mandatory to get both right, taking into account multiple parameters: the stem position, the approach, the bearing surface, the cup coverage and the pelvic orientation during loading. In most cases a "standard" cup position is adequate. However, specific anatomic features might require an individualized approach. This paper aims at reviewing the parameters that impact on the optimal cup position. This should allow for more judicious choices in those particular cases. PMID:26280607

  16. Accuracy of the modified Hardinge approach in acetabular positioning

    PubMed Central

    Goyal, Prateek; Lau, Adrian; McCalden, Richard; Teeter, Matthew G.; Howard, James L.; Lanting, Brent A.

    2016-01-01

    Background The surgical approach chosen for total hip arthroplasty (THA) may affect the positioning of the acetabular component. The purpose of this study was to examine the accuracy in orienting the acetabular component using the modified Hardinge approach. Methods We used our institutional arthroplasty database to identify patients with primary, press-fit, hemispherical acetabular components of a metal-on-polyethylene THA performed between 2003 and 2011. Patients with radiographs obtained 1–3 years after the index procedure were included for measurement of anteversion and inclination angles. Acceptable values of anteversion and abduction angles were defined as 15° ± 10° and 40° ± 10°, respectively. Results We identified 1241 patients from the database, and the modified Hardinge approach was used in 1010 of the patients included in our analysis. The acetabular component was anteverted in the acceptable zone in 54.1% of patients. The abduction angle was within the defined range in 79.2% of patients. Combined anteversion and abduction angles within the defined zone were present in 43.6% of patients. Conclusion Consistent with studies examining accuracy from other approaches, our study reveals that the modified Hardinge approach was only moderately accurate in positioning the acetabular component in the acceptable zone. PMID:27240130

  17. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses.

    PubMed

    Mak, Mathew; Jin, Zhongmin; Fisher, John; Stewart, Todd D

    2011-01-01

    The purpose of the study was to investigate the contact stresses in 3 different acetabular cup rim designs (new, worn, chamfer) during edge loading, after microseparation of ceramic on ceramic hip prostheses. A 3-dimensional finite element analysis was conducted for a 28-mm diameter alumina ceramic bearing with a radial clearance of 40 μm using a normal load of 2500 N under edge loading. At a separation distance of 250 μm, the maximum tensile stress in the "new" design was of similar magnitude to the flexural strength of the alumina material that supports the localized breakdown (stripe wear) of the acetabular cup surface observed clinically. Introducing a 2.5-mm radius chamfer should reduce the maximum tensile stress in the region of 60%. PMID:20149581

  18. Ex vivo estimation of cementless acetabular cup stability using an impact hammer.

    PubMed

    Michel, Adrien; Bosc, Romain; Sailhan, Frédéric; Vayron, Romain; Haiat, Guillaume

    2016-02-01

    Obtaining primary stability of acetabular cup (AC) implants is one of the main objectives of press-fit procedures used for cementless hip arthroplasty. The aim of this study is to investigate whether the AC implant primary stability can be evaluated using the signals obtained with an impact hammer. A hammer equipped with a force sensor was used to impact the AC implant in 20 bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the inserted AC implant was impacted four times with a maximum force comprised between 2500 and 4500 N. An indicator I was determined based on the partial impulse estimation and the pull-out force was measured. The implant stability and the value of the indicator I reached a maximum value for an interference fit equal to 1 mm for 18 out of 20 samples. When pooling all samples and all configurations, the implant stability and I were significantly correlated (R(2) = 0.83). The AC implant primary stability can be assessed through the analysis of the impact force signals obtained using an impact hammer. Based on these ex vivo results, a medical device could be developed to provide a decision support system to the orthopedic surgeons. PMID:26671784

  19. Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

    PubMed

    Brodén, Cyrus; Olivecrona, Henrik; Maguire, Gerald Q; Noz, Marilyn E; Zeleznik, Michael P; Sköldenberg, Olof

    2016-01-01

    Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty. Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated. Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv. Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting. PMID:27478832

  20. Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study

    PubMed Central

    Olivecrona, Henrik; Maguire, Gerald Q.; Noz, Marilyn E.; Zeleznik, Michael P.

    2016-01-01

    Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty. Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated. Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv. Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting. PMID:27478832

  1. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density

    PubMed Central

    Finnilä, Sami; Moritz, Niko; SvedströM, Erkki; Alm, Jessica J; Aro, Hannu T

    2016-01-01

    Background and purpose Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. Patients and methods We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41–78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ −1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2–10) years. Results Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were “at risk” (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the10 cases were “at risk” in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3–48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. Interpretation Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually. PMID:26569616

  2. Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years.

    PubMed

    Reikerås, Olav; Gunderson, Ragnhild B

    2002-01-01

    We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1991-1993 and followed for 7-10 years. During this period, 39 cups were revised because of mechanical loosening, a further 9 had radiolucent lines and 2 focal osteolysis. None of these 11 patients had clinical symptoms. Failure was associated with age, wear and radiolucency/osteolysis. At revision, we found that the soft tissues were discolored, and that most of the coating had disappeared. This design of hydroxyapatite-coated cups has a high rate of debonding and failure. PMID:11928902

  3. Difference in the acetabular cup orientation in standing and supine radiographs.

    PubMed

    Khan, Munir; Beckingsale, Tom; Marsh, Martin; Holland, Jim

    2016-09-01

    Acetabular orientation changes with that of the pelvis during lying and standing. This study was designed to measure these changes. We assessed 17 BHR replacements using EBRA software. The mean acetabular anteversion was more (p = 0.02) on erect than supine radiographs. Linear regression analysis showed that anteversion and inclination increased in some while decreased in others, and Bland and Altman analysis showed wide limits of agreement. The changes in acetabular orientation are thus subject to significant variations between the patients. We suggest studying the factors affecting acetabular orientation in standing to help reduce joint reaction forces and improve outcomes. PMID:27408490

  4. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator.

    PubMed

    McKellop, H A; Shen, F W; Campbell, P; Ota, T

    1999-05-01

    Orthopaedic surgeons must currently choose from several types of ultra high molecular weight polyethylene acetabular cups that differ in their material properties and in the methods used for their sterilization. Information on the wear resistance of these different cups may help in the selection process. This study included two separate tests for wear run on a hip simulator to investigate the effect of molecular weight, calcium stearate, and sterilization methods on the wear resistance of ultra high molecular weight polyethylene acetabular cups. Test 1 revealed nearly identical wear rates for acetabular cups with molecular weights in two distinct ranges, as well as for cups with molecular weights in the same range but with or without calcium stearate added. In Test 2, cups that were sterilized in air with gamma irradiation exhibited lower rates of wear than those sterilized with ethylene oxide, presumably due to the crosslinking induced by the irradiation. In addition, cups that were irradiated while packed in a partial vacuum to minimize oxygen absorbed in the surface layer initially showed lower rates of wear than those irradiated in air, with the wear rates becoming similar as wear penetrated the more oxidized surface layer and the more crosslinked subsurface region. Because these tests were run a few months after the irradiation, the potential effects of long-term oxidation of any residual free radicals in the irradiated materials could not be taken into account. After artificial aging to accelerate oxidative degradation of the materials, the wear rates could be markedly different. Analyses performed after wear indicated that the irradiated (i.e., crosslinked) cups exhibited a smaller proportion of, as well as shorter, fibrils in the wear debris and an increased crystallinity and melting temperature and that gamma irradiation in the low-oxygen environment reduced the level of oxidation and increased the level of crosslinking in the surface region of the cups

  5. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results.

    PubMed

    Ybinger, Thomas; Kumpan, W; Hoffart, H E; Muschalik, B; Bullmann, W; Zweymüller, K

    2007-09-01

    The postoperative position of the acetabular component is key for the outcome of total hip arthroplasty. Various aids have been developed to support the surgeon during implant placement. In a prospective study involving 4 centers, the computer-recorded cup alignment of 37 hip systems at the end of navigation-assisted surgery was compared with the cup angles measured on postoperative computerized tomograms. This comparison showed an average difference of 3.5 degrees (SD, 4.4 degrees ) for inclination and 6.5 degrees (SD, 7.3 degrees ) for anteversion angles. The differences in inclination correlated with the thickness of the soft tissue overlying the anterior superior iliac spine (r = 0.44; P = .007), whereas the differences in anteversion showed a correlation with the thickness of the soft tissue overlying the pubic tubercles (r = 0.52; P = .001). In centers experienced in the use of navigational tools, deviations were smaller than in units with little experience in their use. PMID:17826270

  6. Basic considerations for determining the amount of press fit in acetabular cup endoprostheses as a function of the elastic bone behavior.

    PubMed

    Winter, Werner; Karl, Matthias

    2014-10-01

    Acetabular cup endoprostheses are frequently placed in pelvic bone, employing the mechanical principle of press fit. While a sufficiently stable bone-implant connection is desirable, deformation of the cup and fracture of the pelvis should be avoided. The goal of this work is to demonstrate the importance of the elastic properties of bone on the amount of press fit achievable in a specific situation. On the basis of previous work describing the relation between relative bone mineral density and relative elastic modulus for cortical and trabecular bone, mechanical equations were used for analyzing the press-fit loading situation of an acetabular cup. Additionally, a two-dimensional finite element model was used for visualizing the stress and strain situation in the host bone occurring as a consequence of implant insertion, as well as the effect of moment loads acting on the acetabular cup. Given the fact that oversizing the implant for a specific recipient site is the only clinical means of optimizing press fit, knowledge of the elastic properties of the host bone before implant selection would be beneficial. Such information could, for instance, be derived from intraoperative compressive testing of the host bone. PMID:24937501

  7. Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner

    PubMed Central

    Nebergall, Audrey K; Rader, Kevin; Palm, Henrik; Malchau, Henrik; Greene, Meridith E

    2015-01-01

    Background and purpose In traditional radiostereometric analysis (RSA), 1 segment defines both the acetabular shell and the polyethylene liner. However, inserting beads into the polyethylene liner permits employment of the shell and liner as 2 separate segments, enabling distinct analysis of the precision of 3 measurement methods in determining femoral head penetration and shell migration. Patients and methods The UmRSA program was used to analyze the double examinations of 51 hips to determine if there was a difference in using the shell-only segment, the liner-only segment, or the shell + liner segment to measure wear and acetabular cup stability. The standard deviation multiplied by the critical value (from a t distribution) established the precision of each method. Results Due to the imprecision of the automated edge detection, the shell-only method was least desirable. The shell + liner and liner-only methods had a precision of 0.115 mm and 0.086 mm, respectively, when measuring head penetration. For shell migration, the shell + liner had a precision of 0.108 mm, which was better than the precision of the shell-only method. In both the penetration and migration analyses, the shell + liner condition number was statistically significantly lower and the bead count was significantly higher than for the other methods. Interpretation Insertion of beads in the polyethylene improves the precision of femoral head penetration and shell migration measurements. A greater dispersion and number of beads when combining the liner with the shell generated more reliable results in both analyses, by engaging a larger portion of the radiograph. PMID:26012546

  8. Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty.

    PubMed

    Woerner, Michael; Sendtner, Ernst; Springorum, Robert; Craiovan, Benjamin; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Weber, Markus

    2016-06-01

    Background and purpose - In hip arthroplasty, acetabular inclination and anteversion-and also femoral stem torsion-are generally assessed by eye intraoperatively. We assessed whether visual estimation of cup and stem position is reliable. Patients and methods - In the course of a subgroup analysis of a prospective clinical trial, 65 patients underwent cementless hip arthroplasty using a minimally invasive anterolateral approach in lateral decubitus position. Altogether, 4 experienced surgeons assessed cup position intraoperatively according to the operative definition by Murray in the anterior pelvic plane and stem torsion in relation to the femoral condylar plane. Inclination, anteversion, and stem torsion were measured blind postoperatively on 3D-CT and compared to intraoperative results. Results - The mean difference between the 3D-CT results and intraoperative estimations by eye was -4.9° (-18 to 8.7) for inclination, 9.7° (-16 to 41) for anteversion, and -7.3° (-34 to 15) for stem torsion. We found an overestimation of > 5° for cup inclination in 32 hips, an overestimation of > 5° for stem torsion in 40 hips, and an underestimation < 5° for cup anteversion in 42 hips. The level of professional experience and patient characteristics had no clinically relevant effect on the accuracy of estimation by eye. Altogether, 46 stems were located outside the native norm of 10-20° as defined by Tönnis, measured on 3D-CT. Interpretation - Even an experienced surgeon's intraoperative estimation of cup and stem position by eye is not reliable compared to 3D-CT in minimally invasive THA. The use of mechanical insertion jigs, intraoperative fluoroscopy, or imageless navigation is recommended for correct implant insertion. PMID:26848628

  9. Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty

    PubMed Central

    Woerner, Michael; Sendtner, Ernst; Springorum, Robert; Craiovan, Benjamin; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Weber, Markus

    2016-01-01

    Background and purpose In hip arthroplasty, acetabular inclination and anteversion—and also femoral stem torsion—are generally assessed by eye intraoperatively. We assessed whether visual estimation of cup and stem position is reliable. Patients and methods In the course of a subgroup analysis of a prospective clinical trial, 65 patients underwent cementless hip arthroplasty using a minimally invasive anterolateral approach in lateral decubitus position. Altogether, 4 experienced surgeons assessed cup position intraoperatively according to the operative definition by Murray in the anterior pelvic plane and stem torsion in relation to the femoral condylar plane. Inclination, anteversion, and stem torsion were measured blind postoperatively on 3D-CT and compared to intraoperative results. Results The mean difference between the 3D-CT results and intraoperative estimations by eye was −4.9° (−18 to 8.7) for inclination, 9.7° (−16 to 41) for anteversion, and −7.3° (−34 to 15) for stem torsion. We found an overestimation of > 5° for cup inclination in 32 hips, an overestimation of > 5° for stem torsion in 40 hips, and an underestimation < 5° for cup anteversion in 42 hips. The level of professional experience and patient characteristics had no clinically relevant effect on the accuracy of estimation by eye. Altogether, 46 stems were located outside the native norm of 10–20° as defined by Tönnis, measured on 3D-CT. Interpretation Even an experienced surgeon’s intraoperative estimation of cup and stem position by eye is not reliable compared to 3D-CT in minimally invasive THA. The use of mechanical insertion jigs, intraoperative fluoroscopy, or imageless navigation is recommended for correct implant insertion. PMID:26848628

  10. [New instruments for preparation of the prosthesis socket and primary stability of the acetabular Press-fit cups].

    PubMed

    Pitto, R P; Hofmeister, V

    1999-04-01

    The aim of the present study was to develop surgical instruments necessary to achieve a precisely reamed surface and stable initial fixation. The instruments used to prepare the socket were a gauge-drill guide, a liner for the spigot hole and two spigotted reamers of different design and indentation intended to achieve a precisely reamed surface while preserving subchondral bone. For each reamer we implanted in a synthetic hip model 10 uncemented cups with 2 mm press-fit and loaded at 2.4 kN in the physiological axis (Mod. 8501, Instron, Canton, MA, USA). The micromotion between implant and bone socket was measured using an inductive micrometric measuring system (MultiNCDT-500, Micro-Epsilon, Ortenburg, Germany) and compared with that seen after using conventional instruments. The use of the new reamer of elliptical design significantly reduced the standard deviations of the measured values (p < 0.01 at the ischium and pubis) and also reduced maximum movement (p < 0.01 at the ischium); at the same time, all the components showed overall limited movement (< 150 microns at the ischium, pubis and ilium) under maximum loading (2.4 kN). Manufacturing tolerances, the quality and wear of the instruments, acetabular bone stock and surgical technique all impact on the degree of press-fit obtainable at surgery. The results of our study show that press-fit and initial stability can be optimized by using adequate instruments to prepare the socket. PMID:10379070

  11. Importance of maintaining the basic stress pathway above the acetabular dome during acetabular reconstruction.

    PubMed

    Nie, Yong; Pei, Fuxing; Shen, Bin; Kang, Pengde; Li, Zongming

    2016-07-01

    The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in press-fit acetabular reconstruction of total hip arthroplasty. However, information on the basic stress pathway and its impact factors remains unclear. The objective of this study was to investigate the effects of the orientations and positions of the acetabular component on the basic stress pathway. The basic stress pathway above the acetabular dome was defined as two parts: 3D basic trabecular bone stress distribution and quantified basic cortical bone stress level, using two subject-specific finite element normal hip models. The effects were then analysed by generating 32 reconstructed acetabular cases with different cup abduction and anteversion angles within a range of 35-50° and 10-25°, respectively, and 12 cases with different hip centre heights within a range of 0-15 mm above the acetabular dome. The 3D trabecular stress distribution decreased remarkably in all cases, while the 80% of the basic cortical bone stress level was maintained in cases when the acetabular component was positioned at 10° or 15° anteversion and 40° or 45° abduction angles. The basic stress pathway above the acetabular dome was disturbed when the superior displacement of the hip centre exceeded 5 mm above the anatomical hip centre. Positioning the acetabular component correctly contributes to maintain the stress balance between the acetabular cup and the bone during acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants. PMID:26469561

  12. Comparison of Head Center Position and Screw Fixation Options Between a Jumbo Cup and an Offset Center of Rotation Cup in Revision Total Hip Arthroplasty: A Computer Simulation Study.

    PubMed

    Faizan, Ahmad; Black, Brandon J; Fay, Brian D; Heffernan, Christopher D; Ries, Michael D

    2016-01-01

    Jumbo acetabular cups are commonly used in revision total hip arthroplasty (THA). A straightforward reaming technique is used which is similar to primary THA. However, jumbo cups may also be associated with hip center elevation, limited screw fixation options, and anterior soft tissue impingement. A partially truncated hemispherical shell was designed with an offset center of rotation, thick superior rim, and beveled anterior and superior rims as an alternative to a conventional jumbo cup. A three dimensional computer simulation was used to assess head center position and safe screw trajectories. Results of this in vitro study indicate that a modified hemispherical implant geometry can reduce head center elevation while permitting favorable screw fixation trajectories into the pelvis in comparison to a conventional jumbo cup. PMID:26253481

  13. Analysis of bone formation on porous and calcium phosphate-coated acetabular cups: a randomised clinical [18F]fluoride PET study.

    PubMed

    Ullmark, Gösta; Sörensen, Jens; Nilsson, Olle

    2012-01-01

    We present a study using Fluoride-Positron Emission Tomography (F-PET/CT) to analyse new bone formation in periacetabular bone adjacent to press fit cups following THA. In 16 THA (8 patients) with bilateral hip osteoarthritis simultaneous bilateral total hip arthroplasty (THA) was performed, employing electrochemically applied calcium phosphate coated (HA) cups or porous-coated (PC) cups allocated at random to compare the two sides. A reference group of 13 individuals with a normal healthy hip was used to determine 'normal' bone metabolism. [18F]fluoride -PET/CT was used to analyze bone formation adjacent to the cups 1 week, 4 months and 12 months after surgery. Clinical and radiographic evaluation was performed preoperatively, postoperatively and at 2 years. Bone forming activity had a mean of 5.71, 4.69 and 3.47 SUV around the HA- and 5.04, 4.80 and 3.50 SUV around the PC-cups at 1 week, 4 months and 12 months respectively. Normal bone metabolism was 3.68 SUV. After 1 year activity had declined to normal levels for both groups. The clinical results were good in all cases. HA coating resulted in higher uptake indicating higher bone forming activity after 1 week. F-PET/CT is a valuable tool to analyse bone formation and secondary stabilisation of an acetabular cup. PMID:22547382

  14. Acetabular cup liner and prosthetic head exchange to increase the head diameter for management of recurrent luxation of a prosthetic hip in two dogs.

    PubMed

    Roe, S C; Sidebotham, C; Marcellin-Little, D J

    2015-01-01

    Component malalignment and impingement are possible causes of recurrent luxation following total hip replacement in the dog. In the two cases presented in this report, luxation that was probably due to impingement was managed by exchanging the standard 17 mm prosthetic head for a 24 mm prosthetic head. This required removal of the original acetabular cup liner and placement of a new polyethylene liner that would accept the 24 mm head into the stable acetabular shell. In the first case, a 50 kg Malamute dog, recurrent luxation was initially managed by component alignment revision, iliofemoral suture, triple pelvic osteotomy and a novel lasso technique, without long-term success. After exchanging the head and cup liner, luxation did not recur over a 12-month period. In the second case, a 65 kg Newfoundland dog, impingement was suspected after a second luxation event. Luxation did not recur during the nine months after exchange of the head and cup liner. The larger prosthetic head used in these two cases increased the impingement-free range-of-motion of the joint and increased the translation distance required for luxation (jump distance). PMID:25448927

  15. Cup position alone does not predict risk of dislocation after hip arthroplasty.

    PubMed

    Esposito, Christina I; Gladnick, Brian P; Lee, Yuo-Yu; Lyman, Stephen; Wright, Timothy M; Mayman, David J; Padgett, Douglas E

    2015-01-01

    We used a large prospective institutional registry to determine if there is a 'safe zone' that exists for acetabular component position within which the risk of hip dislocation is low and if other patient and implant factors affect the risk of hip dislocation. Patients who reported a dislocation event within six months after hip arthroplasty surgery were identified, and acetabular component position was measured with anteroposterior radiographs. The frequency of dislocation was 2.1% (147 of 7040 patients). No significant difference was found in the number of dislocated hips among the radiographic zones (±5°,±10°,±15° boundaries). Dislocators <50 years old were less active preoperatively than nondislocators (P=0.006). Acetabular component position alone is not protective against instability. PMID:25249516

  16. PIRAC Ti nitride coated Ti-6AI-4V head against UHMWPE acetabular cup-hip wear simulator study.

    PubMed

    Gutmanas, E Y; Gotman, I

    2004-04-01

    Wear behaviour of TiN(titanium nitride)-coated Ti and Ti-6AI-4V alloy against UHMW polyethylene was studied in hip simulation test. Ti alloys possess an excellent combination of mechanical properties and biocompatibility, however, they suffer from inadequate wear resistance. Thus, their use as articulating components of total joint replacements requires surface hardening, e.g. by TiN. Thirty-two millimetre diameter cp-Ti and Ti-6AI-4V femoral heads were coated with several micrometre thick TiN layers employing an original PIRAC nitriding method based on interaction of Ti alloy substrate with highly reactive monatomic nitrogen. The heads were tested against UHMWPE cups at 37 degrees C in Ringer's solution or in distilled water. Simulator tests were performed at peak pressures of 1.5 and 2.0 MPa in a constant rotation mode at the frequency of 1.5 Hz. The wear of UHMWPE was estimated by weight loss, and the worn metallic and polyethylene surfaces were examined in SEM. The wear rate of UHMWPE cups articulating against PIRAC coated Ti and Ti-6AI-4V after up to 4 x 10(6) cycles was significantly lower than that of UHMWPE articulating against 316L stainless steel. No delamination of TiN coatings was observed after 4 x 10(6) cycles. These results suggest that TiN PIRAC coating on Ti-6AI-4V heads could minimise the wear of total hip replacements without compromising the mechanical properties of the femoral component. PMID:15332594

  17. Effect of acetabular cup design on metal ion release in two designs of metal-on-metal hip resurfacing.

    PubMed

    Cadossi, Matteo; Tedesco, Giuseppe; Savarino, Lucia; Baldini, Nicola; Mazzotti, Antonio; Greco, Michelina; Giannini, Sandro

    2014-10-01

    The purpose of this observational prospective cohort study was to evaluate the serum concentrations of cobalt (Co), chromium (Cr), and nickel (Ni) at a 2-year follow-up in patients operated on with a novel design of hip resurfacing: Romax resurfacing system (RRS). RRS is characterized by the presence of an acetabular notch which theoretically provides a wider range of motion and a reduced incidence of groin pain. The presence of radiolucencies and functional outcome, assessed using the Harris hip score (HHS) and the University of California Activity scale (UCLA), were secondary endpoints. Moreover, these results were compared with those obtained in our previous study from a similar cohort of patients implanted using the Birmingham Hip Resurfacing (BHR) system. At a 2-year follow-up, the serum levels of Co in patients operated on using the RRS were five times higher (p = 0.0002) than those found before surgery (Co, means: 1.04 and 0.20 ng/mL, respectively); similarly, Cr levels were 13 times higher (p < 0.0001) at a 2-year follow-up than before surgery (Cr, means: 1.69 and 0.13 ng/mL, respectively). Ni concentrations (0.42 and 0.78 ng/mL) were not significantly different (p = 0.16), even if they increased 86% after surgery. In the RRS patients, an inverse correlation was found between Co and Cr concentrations and length of follow-up (Co: r = -0.64, p = 0.0096; Cr: r= -0.45, p = 0.08). The serum levels of Co and Cr were not significantly different between RRS (Co: 1.04 ng/mL and Cr: 1.69 ng/mL) and BHR (Co: 1.39 ng/mL and Cr: 2.30 ng/mL) patients at 2 years (p = 0.95 and 0.26 for Co and Cr, respectively). Our results showed that RRS patients achieved an excellent clinical outcome with limited metal ion release. PMID:24962936

  18. The John Charnley Award: Risk Factors for Cup Malpositioning: Quality Improvement Through a Joint Registry at a Tertiary Hospital

    PubMed Central

    Callanan, Mark C.; Jarrett, Bryan; Bragdon, Charles R.; Zurakowski, David; Rubash, Harry E.; Freiberg, Andrew A.

    2010-01-01

    Background Few studies have examined factors that affect acetabular cup positioning. Since cup positioning has been linked to dislocation and increased bearing surface wear, these factors affecting cup position are important considerations. Question/purposes We determined the percent of optimally positioned acetabular cups and whether patient and surgical factors affected acetabular component position. Methods We obtained postoperative AP pelvis and cross-table lateral radiographs on 2061 consecutive patients who received a THA or hip resurfacing from 2004 to 2008. One thousand nine hundred and fifty-two hips had AP pelvic radiographs with correct position of the hip center, and 1823 had both version and abduction angles measured. The AP radiograph was measured using Hip Analysis Suite™ to calculate the cup inclination and version angles, using the lateral film to determine version direction. Acceptable ranges were defined for abduction (30°–45°) and version (5°–25°). Results From the 1823 hips, 1144 (63%) acetabular cups were within the abduction range, 1441 (79%) were within the version range, and 917 (50%) were within the range for both. Surgical approach, surgeon volume, and obesity (body mass index > 30) independently predicted malpositioned cups. Comparison of low versus high volume surgeons, minimally invasive surgical versus posterolateral approach, and obesity versus all other body mass index groups showed a twofold (1.5–2.8), sixfold (3.5–10.7), and 1.3-fold (1.1–1.7) increased risk for malpositioned cups, respectively. Conclusions Factors correlated to malpositioned cups included surgical approach, surgeon volume, and body mass index with increased risk of malpositioning for minimally invasive surgical approach, low volume surgeons, and obese patients. Further analyses on patient and surgical factors’ influence on cup position at a lower volume medical center would provide a valuable comparison. Level of Evidence Level II, prognostic

  19. Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims

    PubMed Central

    Wada, Hiroshi; Mishima, Hajime; Yoshizawa, Tomohiro; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    Background In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible because of direct palpation using a pointer. Imageless navigation using the ACA usually targets patients with normal acetabular morphology. The aim of this study was to investigate the accuracy of imageless navigation using the ACA instead of the APP in patients with normal or deformed acetabular rims. Methods The intraoperative cup position was compared with that obtained from the postoperative computed tomography (CT) images in 18 cases. Results The inclination angle derived from the navigation system was 3.4 ± 5.3 degrees smaller and the anteversion angle was 1.4 ± 3.1 degrees larger than those derived from the CT images. Conclusion The inclination cup angle of the navigation system was significantly inferior to the true value, particularly in cases with large anterior osteophytes. PMID:27073586

  20. Percutaneous screw placement in acetabular posterior column surgery: gender differences in implant positioning.

    PubMed

    Dienstknecht, Thomas; Müller, Michael; Sellei, Richard; Nerlich, Michael; Pfeifer, Christian; Krutsch, Werner; Fuechtmeier, Bernd; Berner, Arne

    2014-04-01

    Percutaneous reduction and periarticular screw implantation techniques have been successfully introduced in acetabular surgery. Image guided navigation techniques might be beneficial in increasing accuracy. However, a thorough understanding of standard values is needed to oversee pitfalls. This cadaver study was designed to identify reliable angulation values for screw implantation in the posterior acetabular column and to provide knowledge of the bony thickness for the periarticular corridor. Gender differences were specifically addressed. 27 embalmed cadaveric hemipelvic specimens (13 male, 14 female) were used. After soft-tissue removal posterior column acetabular screw placement was conducted by one experienced orthopaedic trauma surgeon under visibility. Radiographic verification of ideal screw placement was followed by radiographic assessment in three standard views and angulation values were assessed. Through bony dissection the maximal periarticular canal width was assessed. Various angulation values with regard to anatomical landmarks could be determined in the anteroposterior radiograph, as well as in the iliac oblique and the obturator oblique view. Gender differences were significant for all reference points with the pubic rami involved. The minimal canal width was 1.1cm in female and 1.6 cm in male specimen. The findings provide standard values for safe passages in percutaneous posterior column acetabular surgery. Gender differences have to be taken in consideration when planning the drill corridor. By adherence to standard values, screw placement can be performed safely. PMID:24182644

  1. A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial.

    PubMed

    Troelsen, Anders; Greene, Meridith E; Ayers, David C; Bragdon, Charles R; Malchau, Henrik

    2015-12-01

    Conventional radiostereometric analysis (RSA) for wear is not possible in patients with tantalum cups. We propose a novel method for wear analysis in tantalum cups. Wear was assessed by gold standard RSA and the novel method in total hip arthroplasty patients enrolled in a randomized controlled trial receiving either titanium or tantalum cups (n=46). The novel method estimated the center of the head using a model based on identification of two proximal markers on the stem and knowledge of the stem/head configuration. The novel method was able to demonstrate a pattern of wear that was similar to the gold standard in titanium cups. The novel method offered accurate assessment and is a viable solution for assessment of wear in studies with tantalum cups. PMID:26216229

  2. Acetabular Reconstruction in Total Hip Arthroplasty

    PubMed Central

    Santhanam, Siva Swaminathan; Choi, Jung Woo

    2016-01-01

    The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component selection is mostly based on the amount of bone loss present. In the presence of combined cavitary and segmental defects without superior acetabular coverage, reconstructions with a structural acetabular allograft protected by a cage or a custom-made triflange cage have been one of preferred surgical options. The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent rerevision surgery to a certain extent. But high complication rates have been reported including aseptic loosening, infection, dislocation and metal failure. On the other hand, recent literature is reporting satisfactory outcomes with the use of modular augments combined with a hemispherical shell for major acetabular defect. Highly porous metals have been introduced for clinical use in arthroplasty surgery over the last decade. Their higher porosity and surface friction are ideal for acetabular revision, optimizing biological fixation. The use of trabecular metal cups in acetabular revision has yielded excellent clinical results. This article summarizes author's experience regarding revision acetabular reconstruction options following failed hip surgery including arthroplasty. PMID:27536638

  3. Acetabular Reconstruction in Total Hip Arthroplasty.

    PubMed

    Shon, Won Yong; Santhanam, Siva Swaminathan; Choi, Jung Woo

    2016-03-01

    The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component selection is mostly based on the amount of bone loss present. In the presence of combined cavitary and segmental defects without superior acetabular coverage, reconstructions with a structural acetabular allograft protected by a cage or a custom-made triflange cage have been one of preferred surgical options. The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent rerevision surgery to a certain extent. But high complication rates have been reported including aseptic loosening, infection, dislocation and metal failure. On the other hand, recent literature is reporting satisfactory outcomes with the use of modular augments combined with a hemispherical shell for major acetabular defect. Highly porous metals have been introduced for clinical use in arthroplasty surgery over the last decade. Their higher porosity and surface friction are ideal for acetabular revision, optimizing biological fixation. The use of trabecular metal cups in acetabular revision has yielded excellent clinical results. This article summarizes author's experience regarding revision acetabular reconstruction options following failed hip surgery including arthroplasty. PMID:27536638

  4. Dilemmas in imaging for peri-acetabular osteotomy: the influence of patient position and imaging technique on the radiological features of hip dysplasia.

    PubMed

    Kosuge, D; Cordier, T; Solomon, L B; Howie, D W

    2014-09-01

    Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam. PMID:25183583

  5. Coralline hydroxyapatite in complex acetabular reconstruction.

    PubMed

    Wasielewski, Ray C; Sheridan, Kate C; Lubbers, Melissa A

    2008-04-01

    This retrospective study examined whether a coralline hydroxyapatite bone graft substitute adequately repaired bone defects during complex acetabular reconstructions. Seventeen patients who underwent acetabular revision using Pro Osteon 500 were assessed to determine whether any cups required re-revision, whether bone had incorporated into the coralline hydroxyapatite grafts, and whether the coralline hydroxyapatite grafts resorbed with time. At latest follow-up, no cups required re-revision, but 1 had failed. Radiographic evidence of bone incorporation was observed in every coralline hydroxyapatite graft. Graft resorption was not observed. PMID:19292282

  6. Morphometric assessment of the canine hip joint using the acetabular angle of retrotorsion.

    PubMed

    Doskarova, B; Kyllar, M; Paral, V

    2010-01-01

    Morphometric assessment of the canine hip joint using acetabular angle of retrotorsion was used in this study. The aim of our study was to compare the acetabular angle of retrotorsion (AAR) with values of the Norberg angle (NA) and the hip score (HS) in the Leonberger dog breed and to determine the cut-off point of AAR that distinguish between normal and dysplastic hip status on the basis of Fédération Cynologique Internationale (FCI) hip evaluation. Retrospective analysis of NA and AAR was measured from standard ventrodorsal pelvic radiographs with extended femurs in 387 Leonberger dogs (141 males and 246 females) from 18 to 63 months of age, which were then divided into five age-groups. Through analysis of these radiographs, it was determined that the cut-off point for NA was 105°, AAR was 15°, and the acetabular angle of retrotorsion was positively correlated with Norberg angle and negatively correlated with hip score. The results of our study indicate that the acetabular angle of retrotorsion may represent a reliable morphometric assessment tool in evaluating acetabular cup conformation, and values of AAR may help to assess the FCI grade of canine hip dysplasia. PMID:20740259

  7. Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study

    PubMed Central

    Huang, De-Yong; Zhang, Liang; Zhou, Yi-Xin; Zhang, Chun-Yu; Xu, Hui; Huang, Yong

    2016-01-01

    Background: Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures, and good results have been reported with the use of these cups; however, the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear. This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures. Methods: A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012. Among these patients, two were lost to follow-up. Therefore, 39 patients (39 hips) were finally included in this study. The Harris hip score before and after the surgery, satisfaction level of the patients, and radiographic results were assessed. Results: The mean Harris hip score increased from 34 (range, 8–52) before surgery to 91 (range, 22–100) at the latest follow-up examination (P < 0.001). The results were excellent for 28 hips, good for six, fair for three, and poor for two. Among the 39 patients, 25 (64%) and 10 (26%) were very satisfied and somewhat satisfied, respectively. All cups were found to be fully incorporated, and no evidence of cup migration or periacetabular osteolysis was noted. Conclusions: Despite the technically demanding nature of the procedure, THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures. PMID:27064033

  8. Upward and inward displacements of the acetabular component increase stress on femoral head in single endoprothesis models

    PubMed Central

    Zhang, Zhiqi; Kang, Yan; Chen, Yi; Liao, Weiming

    2009-01-01

    The centre of rotation of the hip can be displaced in hip dysplasia and revision arthroplasty. This study examined the effect of artificial femoral head load after acetabular component displacement in total hip arthroplasty. Sixteen total hip arthroplasty models of human cadaver specimens were reconstructed, and under different acetabular component position, the load around the femoral head was evaluated by strain gages. The results showed that the load was higher in the same specimens when the cup was moved 2 mm inward or upward, especially after the cup was moved more than 6 mm, and the load had an increasing effect in the inward group. In the upward group, an increasing effect happened at 8 mm upward displacement, but the stress value decreased from 4 mm to 6 mm upward displacement. In the same moving distance, the stress of inward displacement is obviously higher than upward displacement. Altogether, the results suggested that for both inward displacement and upward displacement of the acetabular cup, the load around the femoral head increased gradually, while the distance of the inward displacement and the superior displacement was increased. The greater the displacement, the bigger the loading contact stress. The upward displacement caused less stress change on the femoral head. The stress of the 6 mm upward position was lower than nearby positions; perhaps this site represented a stress buffering zone. PMID:19424694

  9. Midterm survivorship of a press-fit, plasma-sprayed, tri-spike acetabular component.

    PubMed

    Klaassen, Mark A; Martínez-Villalobos, Mario; Pietrzak, William S; Mangino, Gerardo P; Guzman, Delfino Carranza

    2009-04-01

    Press-fit acetabular cups without screw holes can limit migration of particulate wear debris and reduce risk of acetabular osteolysis and device loosening. The Tri-Spike cup (Biomet, Inc, Warsaw, Ind) includes a titanium alloy plasma spray porous surface and does not require screw fixation. We retrospectively examined the incidence of cup loosening and acetabular osteolysis after implantation of 45 cups (44 patients) with mean follow-up of 7.3 years (range, 4-9 years). Only one patient (one cup) had evidence of less than 1 mm of retroacetabular radiolucency at 3 years (nonprogressive), which was found to remain firmly fixed during revision of the aseptically loosened femoral component. No cups were removed or revised at latest follow-up. Projected Kaplan-Meier survivorship at 9 years was 100% for cup loosening/revision and 97.8% for radiolucency. PMID:18534453

  10. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    PubMed

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 μm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 μm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small. PMID:26319002

  11. A safe zone for acetabular component position in metal-on-metal hip resurfacing arthroplasty: winner of the 2012 HAP PAUL award.

    PubMed

    Liu, Fei; Gross, Thomas P

    2013-08-01

    A safe zone for acetabular component positioning in hip resurfacing (RAIL: Relative Acetabular Inclination Limit) was calculated based on implant size and acetabular inclination angle (AIA). For AIA below the RAIL, there were no adverse wear failures or dislocations, and only 1% of cases with ion levels above 10 μg/L. Other than high inclination angle and small bearing size, female gender was the only other factor that correlated with high ion levels in the multivariate analysis. Seven hundred sixty-one hip resurfacing cases are included in this study. The UCLA activity score, femoral shaft angle, body mass index, weight, American Society of Anesthesiologists score, combined range of motion, diagnosis, age, gender, implant brand, AIA, bearing size, and duration of implantation were analyzed to determine the potential risk factors for elevated metal ion levels. These findings apply to sub hemispheric metal-on-metal bearings with similar coverage arcs as the Biomet and Corin hip resurfacing brands. Additional problems may occur when these bearings are connected with trunions on stems for total hip arthroplasty. PMID:23540536

  12. The acetabular component: an elliptical monoblock alternative.

    PubMed

    Sculco, Thomas P

    2002-06-01

    The major failure mode of cemented or noncemented acetabular fixation is osteolysis produced by biologic reaction to polyethylene and metallic debris. A monoblock acetabular noncemented component offers advantages in reducing the failure mechanism of acetabular cups. First, there is no extra-articular back surface polyethylene wear. Second, locking rings that may generate metallic debris are eliminated. Third, screw-holes, which decrease the surface area for ingrowth, are not needed, and pelvic entrance points for wear debris are eliminated. Fourth, an elliptical configuration allows better coaptation of the shell to the dome of the acetabulum. I have implanted >2,400 elliptical monoblock acetabular cups with a short-term follow-up of 6.5 years, with >4 years of follow-up in 840 hips. There have been no mechanical failures requiring revision. Four patients have been revised for recurrent hip instability, and one has been revised for infection. The need to convert to an acetabular component with screw fixation because of poor press-fit is <1%. PMID:12068420

  13. Fixation strength analysis of cup to bone material using finite element simulation

    NASA Astrophysics Data System (ADS)

    Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; van der Heide, Emile

    2016-04-01

    Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw inside of cup is effective; however, it has little effect in whole fixation. Therefore, an acetabular cup with good fixation, easy manufacture and easy installation is required. This paper is aiming at evaluating and proposing a new cup fixation design. To prove the strength of the present cup fixation design, the finite element simulation of three dimensional cup with new fixation design was performed. The present cup design was examined with twist axial and radial rotation. Results showed that the proposed cup design was better than the general version.

  14. Acetabular component deformation with press-fit fixation.

    PubMed

    Squire, Matthew; Griffin, William L; Mason, J Bohannon; Peindl, Richard D; Odum, Susan

    2006-09-01

    Acetabular component deformation secondary to forces encountered during insertion is a potential consequence of the press-fit technique. This study characterized the stiffness of Pinnacle 100 cups (DePuy, Warsaw, Ind) via mechanical testing and used this information with intraoperative measurements of cup deformation to calculate the in vivo forces acting on cups inserted during hip arthroplasty in 21 patients. We found that 90.5% of cups had measurable compression deformity, averaging 0.16 +/- 0.16 mm. The corresponding forces acting on these cups averaged 414 +/- 421 N. For hard-on-hard bearing surfaces, such in vivo deformation of acetabular shells may result in negative clinical consequences such as equatorial loading with increased wear and potential seizing of components, chipping of ceramic inserts, or locking mechanism damage. PMID:16950065

  15. Accuracy considerations in navigated cup placement for total hip arthroplasty.

    PubMed

    Langlotz, U; Grützner, P A; Bernsmann, K; Kowal, J H; Tannast, M; Caversaccio, M; Nolte, L-P

    2007-10-01

    Computer assisted orthopaedic surgery (CAOS) technology has recently been introduced to overcome problems resulting from acetabular component malpositioning in total hip arthroplasty. Available navigation modules can conceptually be categorized as computer tomography (CT) based, fluoroscopy based, or image-free. The current study presents a comprehensive accuracy analysis on the computer assisted placement accuracy of acetabular cups. It combines analyses using mathematical approaches, in vitro testing environments, and an in vivo clinical trial. A hybrid navigation approach combining image-free with fluoroscopic technology was chosen as the best compromise to CT-based systems. It introduces pointer-based digitization for easily assessable points and bi-planar fluoroscopy for deep-seated landmarks. From the in vitro data maximum deviations were found to be 3.6 degrees for inclination and 3.8 degrees for anteversion relative to a pre-defined test position. The maximum difference between intraoperatively calculated cup inclination and anteversion with the postoperatively measured position was 4 degrees and 5 degrees, respectively. These data coincide with worst cases scenario predictions applying a statistical simulation model. The proper use of navigation technology can reduce variability of cup placement well within the surgical safe zone. Surgeons have to concentrate on a variety of error sources during the procedure, which may explain the reported strong learning curves for CAOS technologies. PMID:18019461

  16. Relationship between cup position and obturator externus muscle in total hip arthroplasty

    PubMed Central

    2010-01-01

    Background It is often challenging to find the causes for postoperative pain syndromes after total hip replacement, since they can be very allotropic. One possible cause is the muscular impingement syndrome. The most commonly known impingement syndrome is the psoas impingement. Another recently described impingement syndrome is the obturator externus muscle impingement. The aim of this study is to analyze pathological conditions of the Obturator externus and to show possible causes. Methods 40 patients who had undergone a total hip replacement were subjected to clinical and MRI examinations 12 months after the surgery. The Harris Hip Score (HHS) was used to analyze pain and function. Additionally, a satisfaction score and a pain score (VAS) were determined. The MRI allowed for the assessment of the spatial relation between the obturator externus muscle and the acetabulum. Also measured were the acetabular inclination angle as well as the volume and cross-sectional area of the obturator externus muscle. Results The patients were assigned to 3 groups in accordance with their MRI results. Group 1 patients (n = 18) showed no contact between the obturator externus and the acetabulum. Group 2 (n = 13) showed contact, and group 3 (n = 9) an additional clear displacement of the muscle in its course. It was not possible to establish a connection between the imaging findings, the HHS, the VAS, and patient satisfaction. What was striking, however, was a significant difference between the median inclination angle in group 1 (40° ± 5.4°) and group 3 (49° ± 4.7°) (p < 0.05), and the corresponding image-morphological pathology. The average inclination angle in group 2 was 43.3° ± 3.8° Conclusion Contact between the obturator externus muscle and the caudal acetabula border occurs frequently, but is only rarely accompanied by a painful muscular impingement. The position of the acetabula must be seen as one of the main risk factors for contact between the acetabula border

  17. Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.

    PubMed

    Nieuwenhuis, Jeroen J; Malefijt, Jan de Waal; Hendriks, Jan C M; Gosens, Taco; Bonnet, Michel

    2005-06-01

    A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with different acetabular shell types were specifically analysed. Pelvic osteolysis first became manifest in the acetabular bone opposite to the holes in the metal shell. Osteolysis occurred predominantly adjacent to the central hole in the metal shell of threaded cups; widespread and larger defects were found in press fit cups with peripheral screw holes. Kaplan Meier survival analysis demonstrated a higher probability for retaining the threaded cup at 6 years (96%; 95%-confidence interval: 93-99%) compared to the survival of the press fit cup (66%; 95%-CI: 56-77%). The results suggest a negative relationship between backside wear, the larger number of holes in the cup, the extent of osteolysis and survival rate of the press fit cups. Based on these findings and supported by similar reports about osteolysis related to the same cup design, it was hypothesised that backside wear due to the insufficient locking mechanism of the Omnifit acetabular cup was the major cause of the unsatisfactory results in our patients. For this reason we discontinued using this type of uncemented socket. PMID:16035702

  18. Placement of the acetabular component.

    PubMed

    Beverland, D E; O'Neill, C K J; Rutherford, M; Molloy, D; Hill, J C

    2016-01-01

    Ideal placement of the acetabular component remains elusive both in terms of defining and achieving a target. Our aim is to help restore original anatomy by using the transverse acetabular ligament (TAL) to control the height, depth and version of the component. In the normal hip the TAL and labrum extend beyond the equator of the femoral head and therefore, if the definitive acetabular component is positioned such that it is cradled by and just deep to the plane of the TAL and labrum and is no more than 4mm larger than the original femoral head, the centre of the hip should be restored. If the face of the component is positioned parallel to the TAL and psoas groove the patient specific version should be restored. We still use the TAL for controlling version in the dysplastic hip because we believe that the TAL and labrum compensate for any underlying bony abnormality. The TAL should not be used as an aid to inclination. Worldwide, > 75% of surgeons operate with the patient in the lateral decubitus position and we have shown that errors in post-operative radiographic inclination (RI) of > 50° are generally caused by errors in patient positioning. Consequently, great care needs to be taken when positioning the patient. We also recommend 35° of apparent operative inclination (AOI) during surgery, as opposed to the traditional 45°. PMID:26733639

  19. Finite element analysis of the impingement on the acetabular liner rim due to wear of the acetabular liner surface

    NASA Astrophysics Data System (ADS)

    Saputra, Eko; Anwar, Iwan Budiwan; Ismail, Rifky; Jamari, J.; van der Heide, Emile

    2016-04-01

    This workstudies the impingement on the rim of acetabular liner due to wear on the surface of acetabular liner using finite element simulation. A three dimensional contact model between a femoral head and an acetabular liner was developed. There are three steps in this simulation, i.e. creating the virtualwear on the surface of acetabular liner, applying the load at the femoral head, and rotating the femoral head from neutral position till the impingement occurrence. The virtualwear is created based on the data of wear depth which was obtained from literature. Results showed that the wear on the acetabular liner surface wouldaffected the impingement occurrence, in which the impingement angle becomes narrow. In addition, the failure possibility of the acetabular liner rimwould become higher.

  20. The Results of Long-term Follow-up of Total Hip Arthroplasty Using Hydroxyapatite-coated Cups

    PubMed Central

    Han, Chang-Dong; Shin, Keun-Young; Lee, Hyun-Hee; Park, Kwan-Kyu; Yang, Ick-Hwan

    2015-01-01

    Purpose The aim of this study was to report the long-term outcome and the failure mechanism of cementless total hip arthroplasty (THA) using hydroxyapatite (HA)-coated acetabular cup. Materials and Methods From January 1992 to May 1994, a total of 123 consecutive cementless primary THAs were performed using a HA-coated acetabular cup with metal-on-polyethylene articulation. We retrospectively evaluated 66 hips available for follow-up at a mean 18.3 years (range, 10.4-23.6 years). The survival analysis was performed by the Kaplan-Meier method. We defined end point as any failure that required a reoperation of acetabular component. Results Thirty-nine of 66 hips (59.1%) were defined as a failure for progressive acetabular osteolysis or aseptic loosening of the cup. Acetabular osteolysis was observed in 47 hips (71.2%) and 33 hips (50.0%) were revised because of cup loosening. The Kaplan-Meier method showed the survival rate of the acetabular cup to be 46.3% at 15 years and 34.8% at 20 years for any failure that required a reoperation of acetabular component. Conclusion The long-term survival rate of THA using HA-coated acetabular cup was unsatisfactory, and it was attributed to vulnerable property of HA coating and progressive osteolysis. PMID:27536628

  1. Relation of the Norberg angle and position of the femoral head centre to the dorsal acetabular edge in evaluation of canine hip dysplasia.

    PubMed

    Skurková, L; Hluchý, M; Lacková, M; Mihalová, M; Ledecký, V

    2010-01-01

    Canine hip dysplasia (CHD) is a locomotive-system disease in dogs, which in many countries is the target of screening programs aimed at reducing the prevalence of CHD among descendants of predisposed dog breeds. Despite the efforts to apply genetic testing or ultrasound diagnostics in diagnosing CHD (as is common in human medicine), the main diagnostic process in veterinary medicine is by radiographic examination. The main two parameters which are used in diagnosing HD are the Norberg angle (NA) and the position of femoral head centre to the dorsal acetabular edge (FHC/DAE). We examined the relationship between these two parameters in the process of the determination of CHD degree by evaluating 225 randomly selected radiographs which were made during the period from 1993 to 2008. The aim of our study was to examine the validity of these two parameters in CHD classification as used in three different classification programs. Using Pearson's correlation coefficient, the value of which was 0.85 (p <0.05), we observed a positive correlation. Comparing the three scoring systems for CHD evaluation, we found that the final degree of CHD was similar for 78% to 85% of cases using Flückiger's scoring system versus a modified scoring system of 5 parameters without FHC/DAE. Results were significant. PMID:20830451

  2. Polyethylene wear in uncemented acetabular components.

    PubMed

    Hernandez, J R; Keating, E M; Faris, P M; Meding, J B; Ritter, M A

    1994-03-01

    We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated with uncemented femoral components (0.22 mm/year) was significantly higher than the wear rate (0.15 mm/year) of cups articulated within cemented femoral components (p < 0.05). These results can be compared with previously reported wear rates of 0.08 mm/year for cemented all-polyethylene cups and 0.11 mm/year for cemented metal-backed cups. The higher wear rates of uncemented arthroplasties could jeopardize the long-term results of this type of hip replacement. PMID:8113288

  3. Implication of acetabular width on the anteroposterior pelvic radiograph of patients with developmental dysplasia of the hip.

    PubMed

    Nie, Yong; Pei, Fuxing; Shen, Bin; Kang, Pengde; Li, Zongming

    2015-03-01

    Radiographic parameters that can help acetabular reconstruction during total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH) are few. The radiographs of 138 dysplastic hips that had undergone cementless THA were evaluated regarding the acetabular width above the acetabular component and the coverage of the component by native bone. The acetabular reconstruction process was simulated using 3D models from CT data, and the acetabular component coverage was calculated in 3D space based on the measurement and algorithm we proposed. Significant positive correlation between the acetabular width and the acetabular component coverage was found. Our study introduced a useful parameter, which can mark the superior reference position of the acetabular component for acetabular reconstruction in DDH patients. PMID:25311162

  4. Pelvic and acetabular fractures

    SciTech Connect

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair.

  5. Uncemented acetabular components. Histologic analysis of retrieved hydroxyapatite-coated and porous implants.

    PubMed

    Bauer, T W; Stulberg, B N; Ming, J; Geesink, R G

    1993-04-01

    Histologic sections of five hydroxyapatite-coated acetabular components retrieved at autopsy (2 dual geometry and 3 threaded cup designs) were analyzed, and the extent and pattern of bone apposition were compared with that of an uncoated, porous (beaded) dual geometry acetabular cup that had been removed for repeated dislocations. The results show hydroxyapatite and bone apposition most prominent in areas of likely load transmission, primarily around the peripheral rim of the dual-geometry cups and at the peaks of the threads of the screw cups. Hydroxyapatite and bone may have been removed by remodeling from the grooves between the threads. Although no significant wear debris was identified, the screw holes were incompletely covered by bone. The dual-geometry designs generally showed somewhat more bone apposition than the threaded cups, but all implants demonstrated less bone than might have been predicted from radiographs. PMID:8386747

  6. Traumatic medial displacement of Rotalok uncemented acetabular component. A case report.

    PubMed

    Charnley, G J; Ridge, J; Ribbans, W J

    1994-04-01

    The failure of uncemented acetabular components has been described in association with component wear, disassembly, and proximal migration. The authors report a case of medial displacement following minor trauma some 18 months after surgery. The component involved differs in design from both press-fit, porous-coated or screw-in, fully threaded acetabular cups. The authors suggest that additional screws should be inserted to enhance long-term stability. PMID:8014654

  7. Protrusio After Medial Acetabular Wall Breach in Total Hip Arthroplasty

    PubMed Central

    Martin, Christopher T.; Heiner, Anneliese D.; Baer, Thomas E.; Pugely, Andrew J.; Noiseux, Nicolas O.

    2015-01-01

    Background Medial protrusio is a recognized complication of total hip arthroplasty, but it is not known if a medial wall breach during cup implantation increases the risk. We thus investigated the effect of up to a 2 cm defect in the medial acetabular wall in a cadaveric model. Separately, we investigated the ability of acetabular screws to rescue the construct. Methods Nine human fresh-frozen hemipelves were reamed medially to create the defect, implanted with acetabular cups, and then loaded to failure. The nine contralateral hemipelves were reamed in a standard fashion and served as controls. Separately, nine hemipelves with a medial defect were augmented with two acetabular screws each, then loaded to failure, with the contralateral side as a control. Load-to-failure, stiffness, and energy were recorded. Findings The presence of a medial wall defect decreased the load-to-failure by a mean of 26% (5710 v. 4221 N, p=0.024). The addition of two acetabular screws did not rescue the construct (mean 27% decrease, 4082 v. 2985 N, p=0.024). The majority of specimens failed in a supra-physiologic range of force. Bone density correlated with failure loads (R2 range of 0.54-0.78), and osteoporotic specimens were more likely to fail at a physiologic range, consistent with forces experienced during minor stumbles or falls. Interpretation Osteoporotic patients with a medial wall defect after hip arthroplasty may be susceptible to fracture during activities of daily living. Protected weight bearing with an assistive device may be reasonable in order to minimize fall risk until cup ingrowth is achieved. PMID:26361450

  8. Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.

    PubMed

    Garavaglia, Guido; Lübbeke, Anne; Barea, Christophe; Roussos, Constantinos; Peter, Robin; Hoffmeyer, Pierre

    2011-07-01

    Total hip arthroplasty (THA) with well designed cementless acetabular implants has shown excellent results. The purpose of this study was to assess our clinical and radiological outcomes using an uncemented cup. We conducted a prospective cohort study including all consecutive primary THAs performed with the Morscher press-fit cup, an uncemented non-modular acetabular component, between March 1996 and December 1998. Patients were evaluated at ten years with clinical and radiological follow-up, patient satisfaction and questionnaire assessment using the Harris hip score (HHS), Merle d'Aubigné and Postel score, the UCLA score, the 12-item short-form health survey (SF-12) and a visual analog scale. Five hundred sixty-one THAs were performed in 518 patients. At 120 months (± 7.3 months), 303 patients with 335 THAs were still available for follow-up. None of the patients had required cup revision for aseptic loosening. At ten years, the cup survivorship was 98.8% (95% CI 97.4-99.5) with cup revision for any cause as an endpoint. No radiolucencies were seen around the cups, but osteolytic defects involved 21 stems (8.3%). Mean total linear polyethylene wear was 0.9 mm. The Morscher acetabular replacement cup provides excellent results at ten years. There were no revisions for aseptic loosening of the cup, and no osteolytic defects were found around the cup. Patient satisfaction was high and the clinical results were very good. PMID:20524114

  9. Quantification of clearance and creep in acetabular wear measurements

    PubMed Central

    Gregory, Thomas; Vandenbussche, Eric

    2016-01-01

    Background This study aimed to measure femoral head penetration before occurrence of real wear, and to quantify the portions attributable respectively to clearance and plastic deformations in various acetabular designs. Methods We analyzed CT scans from 15 patients at ‘day five’ after total hip arthroplasty (THA). All patients received Exafit® femoral stems and 28 mm heads: 5 patients had cemented Durasul® all-PE cups, 5 patients had un-cemented Allofit® metal-backed cups, and 5 patients had un-cemented Stafit® dual-mobility cups. We also analyzed CT scans of samples of the three head-cup combinations to compare in vivo and in vitro measurements. Results The mean femoral head penetration measured on ‘day five’ was lower for all-PE cups (0.196 mm) than for metal-backed cups (0.551 mm) and dual-mobility cups (0.634 mm). Conclusions The present study indicates that isolated measurements of femoral head penetration include 0.15–0.46 mm of radial clearance and 0.05–0.27 mm of creep, and confirms that the majority of so-called bedding-in observed in the first post-operative months is not entirely due to wear. PMID:27162781

  10. Influence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.

    PubMed

    Urbański, Wiktor; Krawczyk, Artur; Dragan, Szymon Ł; Kulej, Mirosław; Dragan, Szymon F

    2012-01-01

    Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite coatings do not meet expectation and do not provide good clinical result. The object of the study was to evaluate the influence of acetabular cup surface modification on fixation and bone remodelling in total hip arthroplasty. Clinical and radiological outcomes were evaluated in patients two years after cementless total hip replacement. Two groups were compared: patients with acetabular component with uncoated titanium surface and patients with hydroxyapatite-coated acetabular surface. Hips X-rays were analysed for early signs of losing stability of acetabular cups. Two years after surgery the analysis of X-rays did not reveal any statistical differences in stability, migration of acetabular components of endoprosthesis between both groups. No differences were also observed in bone remodelling around implants. Particularly high percentage of cups, i.e. 17.64%, were classified into the group with high risk of early implant loosening, i.e., the group with HA coatings. Hydroxyapatite coatings on titanium cementless acetabular cups implanted by press-fit technique have no influence on their stability, bone-implant fixation and the remodelling of bone surrounding an implant two years after surgery. PMID:22793261

  11. Massive acetabular bone loss: Limits of trabecular metal cages

    PubMed Central

    Villanueva-Martínez, Manuel; Ríos-Luna, Antonio; Diaz-Mauriño, Juán

    2011-01-01

    Massive acetabular bone loss (more than 50% of the acetabular area) can result in insufficient native bone for stable fixation and long-term bone ingrowth of conventional porous cups. The development of trabecular metal cages with osteoconductive properties may allow a more biological and versatile approach that will help restore bone loss, thus reducing the frequency of implant failure in the short-to-medium term. We report a case of massive bone loss affecting the dome of the acetabulum and the ilium, which was treated with a trabecular metal cage and particulate allograft. Although the trabecular metal components had no intrinsic stability, they did enhance osseointegration and incorporation of a non-impacted particulate graft, thus preventing failure of the reconstruction. The minimum 50% contact area between the native bone and the cup required for osseointegration with the use of porous cups may not hold for new trabecular metal cups, thus reducing the need for antiprotrusio cages. The osteoconductive properties of trabecular metal enhanced allograft incorportation and iliac bone rebuilding without the need to fill the defect with multiple wedges nor protect the reconstruction with an antiprotrusio cage. PMID:21221229

  12. Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

    PubMed Central

    Shen, Fu-Wen; Lu, Zhen

    2010-01-01

    Background The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. Questions/purposes We asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in the liner affected by thickness? Methods Wear rates were measured in a hip simulator and stresses were calculated using finite element modeling. Results Without crosslinking, the wear rate was 4% to 10% greater with a 36-mm diameter than a 28-mm diameter. With crosslinking, wear was 9% lower with a 36-mm diameter without metal backing and 4% greater with metal backing. Reducing the thickness from 6 mm to 3 mm increased the contact stress by 46%, but the wear rate decreased by 19%. Conclusions The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm. Clinical Relevance The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated, neither wear nor stresses in the polyethylene are limiting factors in the use of larger-diameter, thinner cups to resist dislocation. PMID:20848244

  13. Current concept in dysplastic hip arthroplasty: Techniques for acetabular and femoral reconstruction

    PubMed Central

    Bicanic, Goran; Barbaric, Katarina; Bohacek, Ivan; Aljinovic, Ana; Delimar, Domagoj

    2014-01-01

    Adult patients with developmental dysplasia of the hip develop secondary osteoarthritis and eventually end up with total hip arthroplasty (THA) at younger age. Because of altered anatomy of dysplastic hips, THA in these patients represents technically demanding procedure. Distorted anatomy of the acetabulum and proximal femur together with conjoined leg length discrepancy present major challenges during performing THA in patients with developmental dysplasia of the hip. In addition, most patients are at younger age, therefore, soft tissue balance is of great importance (especially the need to preserve the continuity of abductors) to maximise postoperative functional result. In this paper we present a variety of surgical techniques available for THA in dysplastic hips, their advantages and disadvantages. For acetabular reconstruction following techniques are described: Standard metal augments (prefabricated), Custom made acetabular augments (3D printing), Roof reconstruction with vascularized fibula, Roof reconstruction with pedicled iliac graft, Roof reconstruction with autologous bone graft, Roof reconstruction with homologous bone graft, Roof reconstruction with auto/homologous spongious bone, Reinforcement ring with the hook in combination with autologous graft augmentation, Cranial positioning of the acetabulum, Medial protrusion technique (cotyloplasty) with chisel, Medial protrusion technique (cotyloplasty) with reaming, Cotyloplasty without spongioplasty. For femoral reconstruction following techniques were described: Distraction with external fixator, Femoral shortening through a modified lateral approach, Transtrochanteric osteotomies, Paavilainen osteotomy, Lesser trochanter osteotomy, Double-chevron osteotomy, Subtrochanteric osteotomies, Diaphyseal osteotomies, Distal femoral osteotomies. At the end we present author’s treatment method of choice: for acetabulum we perform cotyloplasty leaving only paper-thin medial wall, which we break during

  14. Current concept in dysplastic hip arthroplasty: Techniques for acetabular and femoral reconstruction.

    PubMed

    Bicanic, Goran; Barbaric, Katarina; Bohacek, Ivan; Aljinovic, Ana; Delimar, Domagoj

    2014-09-18

    Adult patients with developmental dysplasia of the hip develop secondary osteoarthritis and eventually end up with total hip arthroplasty (THA) at younger age. Because of altered anatomy of dysplastic hips, THA in these patients represents technically demanding procedure. Distorted anatomy of the acetabulum and proximal femur together with conjoined leg length discrepancy present major challenges during performing THA in patients with developmental dysplasia of the hip. In addition, most patients are at younger age, therefore, soft tissue balance is of great importance (especially the need to preserve the continuity of abductors) to maximise postoperative functional result. In this paper we present a variety of surgical techniques available for THA in dysplastic hips, their advantages and disadvantages. For acetabular reconstruction following techniques are described: Standard metal augments (prefabricated), Custom made acetabular augments (3D printing), Roof reconstruction with vascularized fibula, Roof reconstruction with pedicled iliac graft, Roof reconstruction with autologous bone graft, Roof reconstruction with homologous bone graft, Roof reconstruction with auto/homologous spongious bone, Reinforcement ring with the hook in combination with autologous graft augmentation, Cranial positioning of the acetabulum, Medial protrusion technique (cotyloplasty) with chisel, Medial protrusion technique (cotyloplasty) with reaming, Cotyloplasty without spongioplasty. For femoral reconstruction following techniques were described: Distraction with external fixator, Femoral shortening through a modified lateral approach, Transtrochanteric osteotomies, Paavilainen osteotomy, Lesser trochanter osteotomy, Double-chevron osteotomy, Subtrochanteric osteotomies, Diaphyseal osteotomies, Distal femoral osteotomies. At the end we present author's treatment method of choice: for acetabulum we perform cotyloplasty leaving only paper-thin medial wall, which we break during acetabular

  15. Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: discussion of a biomechanical study.

    PubMed

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Iwase, Hideaki

    2013-05-01

    In total hip arthroplasty of the acetabular roof fixed by press-fit without screw fixation, there is little possibility for loosening to occur, because it is difficult for wear debris to enter between the cup and the acetabular roof, as screw holes are not present. However, stability is provided only by contact. In the case of acetabular dysplasia, it is not well understood whether sufficient initial fixation power is provided. We performed a torsion test and a lever-out test. In the torsion test, in the case of a normal hip joint, as the cup grew bigger, the fixation power tended to increase in strength. In the acetabular dysplasia model, with cups of each size, as the protrusion angle increased, the fixation power of the cup tended to become weak. When the protrusion angle approaches 15 degrees, we must use a cup that is 4 mm larger than the original cup to achieve the same initial fixation power. Furthermore, when the protrusion angle is 15 degrees in cups that are over 48 mm in size, we obtain fixation power that is theoretically adequate, but when small cups, for example, 46 mm in size are set with protrusion, the initial fixation power decreases significantly, and we cannot obtain a fixation power that is theoretically adequate. PMID:23412291

  16. Patient-specific acetabular shape modelling: comparison among sphere, ellipsoid and conchoid parameterisations.

    PubMed

    Cerveri, Pietro; Manzotti, Alfonso; Baroni, Guido

    2014-04-01

    The shape of the human acetabular cup was commonly represented as a hemisphere, but different geometries and patient-specific shapes have been recently proposed in the literature. Our aim was to test the limits of the sphericity assumption by comparing three different parameterisations, namely the sphere, the ellipsoid and the rotational conchoid. Models of hip surfaces, reconstructed from CT scans taken from Caucasian race cadavers and patients, were automatically processed to extract the acetabular surface. Two separate analyses were carried out on the overall acetabular shape, including both the acetabular fossa and the lunate surface (case A) and acetabular cup represented by the lunate surface only (case B). Nonlinear gradient-based and evolutionary computation approaches were implemented for the fitting process. Minor differences from the three idealised geometries were detected (median values of the fitting errors < 1 mm). Nonetheless, the sphere fitting was found to be statistically different from both the ellipsoid (p < 2.50e - 10) and the conchoid (p < 1.07e - 09), whereas no statistical difference was detected between the ellipsoid and the conchoid for case A. Significance of the difference between ellipsoid and sphere (p < 4.55e - 12) and between conchoid and sphere (p < 1.93e - 11) was found for case B as well. Interestingly, for case B statistical difference was detected between the ellipsoid and the conchoid. In conclusion, we synthesise that the morphology of the overall acetabular cup can be parameterised both with an ellipsoid shape and with a conchoid shape as well with superior quality than the simple sphere. Differently, if one considers just the lunate surface, better fitting results are expected when using the ellipsoid. PMID:22789071

  17. A histological study of retrieved Cambridge acetabular components.

    PubMed

    Brooks, Roger A; Field, Richard E; Jones, Eric; Sood, Asheesh; Rushton, Neil

    2010-01-01

    A new uncemented acetabular component, the Cambridge cup, has been designed to mimic the anatomy and physiology of subchondral bone in order to minimise stress shielding and enhance long-term component stability. Cambridge cups were implanted in a cohort of 50 women who presented with displaced sub-capital fracture of the femoral neck. The cups were manufactured with an hydroxyapatite (HA) coating. Twenty six cups were implanted after removal of the HA. Twelve Cambridge cups were retrieved post-mortem between two and 84 months after implantation. Histological and histomorphometric testing was undertaken to analyse the residual HA coating thickness, bone apposition to the implant surface and particulate wear debris in the surrounding tissues. The HA-coated implants showed significantly greater bone apposition to the implant surface with significantly less fibrous tissue formation than the uncoated implants. Where HA resorption occurred, bone and bone marrow was seen adjacent to the implant. Excessive wear of the ultra high molecular weight polyethylene liner was not seen. The HA-coated components demonstrated good initial bone implant bonding and the flexible carbon polymer appeared to maintain stability following HA resorption. The uncoated implants showed little or no bony apposition but had a fibrous membrane apposed to the implant surface. This may be explained by a combination of micro-motion at the bone implant interface and having a component surface finish that was poorly suited to osseous attachment. Hydroxyapatite coated acetabular components can provide reliable osseous attachment. Subsequent HA resorption need not compromise medium-term osseous fixation to an appropriate implant surface. PMID:20235075

  18. Porous Tantalum Buttress Augments for Severe Acetabular Posterior Column Deficiency.

    PubMed

    Meneghini, R Michael; Hull, Jason R; Russo, Glenn S; Lieberman, Jay R; Jiranek, William A

    2015-11-01

    In revision total hip arthroplasty (THA), consensus is lacking regarding the optimal method for reconstruction of the most severe acetabular defects. Porous tantalum (TM) buttress augments were designed for the most severe postero-superior defects. The purpose of this study was to report the results of a consecutive series of acetabular reconstructions utilizing TM buttress augments. Eight complex acetabular reconstructions utilizing a TM buttress augment were performed at two centers. All were Paprosky 3A or Paprosky 3B bone loss classification, with severe superior and posterior column deficiency where wedge augments were insufficient for mechanical support. The acetabular cup sizes ranged from 64-78, and a buttress shim was used in 7 of 8 cases. Clinical and radiographic follow-up averaged 16.5 months (range, 10-28) and no cases were lost to follow-up. There were no cases of clinical or radiographic loosening, and no case had required reoperation or revision. All patients except one were ambulating with either no assist device or a single cane at final follow-up. There was one complication of an iliac wing fracture noted incidentally on postoperative x-rays in the lone patient in whom a buttress shim was not used. At short-term follow-up, TM acetabular buttress augments appear to effectively substitute for the use of structural allografts or cages, which would otherwise be used in this challenging setting. The potential for biologic fixation is promising for the durability of these reconstructions; however, longer-term follow-up is required for full evaluation. PMID:26680404

  19. Optimal acetabular orientation for hip resurfacing.

    PubMed

    Grammatopoulos, G; Pandit, H; Glyn-Jones, S; McLardy-Smith, P; Gundle, R; Whitwell, D; Gill, H S; Murray, D W

    2010-08-01

    Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47 degrees, 10 degrees to 81 degrees) and anteversion angle (14 degrees, 4 degrees to 34 degrees) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46 degrees (29 degrees to 60 degrees) and 16 degrees (4 degrees to 30 degrees) respectively, but the variation was greater. Assuming an accuracy of implantation of +/- 10 degrees about a target position, the optimal radiographic position was found to be approximately 45 degrees of inclination and 20 degrees of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45 degrees (+/- 10) and anteversion of 20 degrees (+/- 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40 degrees and an anteversion of 25 degrees. PMID:20675749

  20. Traumatic Periprosthetic Acetabular Fracture Treated with One-Stage Exchange and Bone Reconstruction Using a Synthetic Bone Graft Substitute

    PubMed Central

    2016-01-01

    A case of a traumatic periprosthetic acetabular fracture in an elderly patient, which was treated by one-stage hip exchange with implantation of an antiprotrusio cage and reconstruction of the acetabular bone loss with an injectable calcium sulphate/hydroxyapatite bone graft substitute, is reported. The paste-like bone graft substitute was injected through the holes of the antiprotrusio cage. After a setting time of 15 minutes, a low-profile cup was cemented onto the cage using polymethylmethacrylate and a new stem was inserted. The patient was encouraged to ambulate three days postoperatively weight-bearing as tolerated. At the one-year follow-up visit the patient was ambulatory and full weight-bearing without any walking aids. The follow-up radiographs demonstrated stable position and articulation of the revision hip arthroplasty with no signs of loosening of the antiprotrusio cage. However, the most interesting finding was that the bone graft substitute had remodelled to a great extent into bone. This calcium sulphate/hydroxyapatite composite shows high osteoconductive potential and can be used to regenerate bone stock in revision arthroplasty. PMID:27446621

  1. Traumatic Periprosthetic Acetabular Fracture Treated with One-Stage Exchange and Bone Reconstruction Using a Synthetic Bone Graft Substitute.

    PubMed

    Svacina, Jan

    2016-01-01

    A case of a traumatic periprosthetic acetabular fracture in an elderly patient, which was treated by one-stage hip exchange with implantation of an antiprotrusio cage and reconstruction of the acetabular bone loss with an injectable calcium sulphate/hydroxyapatite bone graft substitute, is reported. The paste-like bone graft substitute was injected through the holes of the antiprotrusio cage. After a setting time of 15 minutes, a low-profile cup was cemented onto the cage using polymethylmethacrylate and a new stem was inserted. The patient was encouraged to ambulate three days postoperatively weight-bearing as tolerated. At the one-year follow-up visit the patient was ambulatory and full weight-bearing without any walking aids. The follow-up radiographs demonstrated stable position and articulation of the revision hip arthroplasty with no signs of loosening of the antiprotrusio cage. However, the most interesting finding was that the bone graft substitute had remodelled to a great extent into bone. This calcium sulphate/hydroxyapatite composite shows high osteoconductive potential and can be used to regenerate bone stock in revision arthroplasty. PMID:27446621

  2. Uncemented acetabular components with femoral head autograft for acetabular reconstruction in developmental dysplasia of the hip: a concise follow-up report at a mean of twenty years.

    PubMed

    Abdel, Matthew P; Stryker, Louis S; Trousdale, Robert T; Berry, Daniel J; Cabanela, Miguel E

    2014-11-19

    We previously reported the five to twelve-year results of total hip arthroplasty with an uncemented acetabular component and an autogenous femoral head graft in forty-four consecutive hips with developmental dysplasia. The goal of the present study was to report the implant survival rate, status of bone grafts, and clinical outcomes in thirty-five of these hips (in twenty-nine patients) followed for a mean of 21.3 years. Functional, radiographic, and survivorship results were examined. Radiographic analysis revealed an average cup inclination angle of 43° and a mean arc of cup coverage by the graft of 30°. The twenty-year survivorship free from acetabular revision was 66% (twelve acetabular revisions; eight since our previous report). Of the twelve revisions, nine were for liner wear and/or osteolysis, one was for a liner fracture, one was for aseptic loosening, and one was for instability. All bone grafts healed to the pelvis. The graft facilitated revision cup placement as no additional structural grafts or metal augments were required. We concluded that an uncemented porous-coated socket used in conjunction with a bulk femoral head autograft provides good long-term fixation and restores bone stock. PMID:25410505

  3. Open-configuration MRI study of femoro-acetabular impingement.

    PubMed

    Yamamura, Mitsuyoshi; Miki, Hidenobu; Nakamura, Nobuo; Murai, Masakazu; Yoshikawa, Hideki; Sugano, Nobuhiko

    2007-12-01

    Femoro-acetabular impingement has been proposed as a causative factor of primary hip osteoarthritis. However, primary osteoarthritis of the hip is infrequent in Japan and other Asian countries, even though the hips of Asians frequently sustain impingement, since the Asian lifestyle commonly requires a larger range of hip motion than the Western lifestyle. Therefore, using open-configuration MRI, we investigated whether impingement actually occurs during some traditional Japanese hip positions. The hips of 5 healthy Japanese females were examined in 5 sitting postures: 1) sitting straight; 2) bowing while sitting straight; 3) sitting cross-legged; 4) W-sitting; and 5) squatting. The impingement point was detected by multiple plane reconstructed (MPR) views along with the acetabular rim depicted circumferentially. Impingement was considered to have occurred when, on MRI, the anterior femoral head-neck junction approached the acetabular rim and the femoral head was seen to float from the bottom of the acetabulum with the acetabular rim acting as a fulcrum. Impingement was observed in all volunteers in the W-sitting position, and in 2 of 5 volunteers during squatting. These findings show that impingement occurs frequently during daily Japanese activities. Thus, depending on race, femoro-acetabular impingement might not always cause primary osteoarthritis of the hip. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1582-1588, 2007. PMID:17600811

  4. Direct high-resolution ion beam-profile imaging using a position-sensitive Faraday cup array

    SciTech Connect

    Panitzsch, Lauri; Stalder, Michael; Wimmer-Schweingruber, Robert F.

    2009-11-15

    Ion sources have wide-spread use in a multitude of applications. For many, an accurate knowledge, or better, an accurate imaging, of the beam profile and intensity is an important criterion. We are developing an ion source to calibrate instruments for space-based measurements of solar wind and suprathermal particles in the energy range from below 1 keV/nuc to above 200 keV/nuc. In order to establish accurate beam profiles for calibration purposes, we have developed a new method based on an array of very small (diameter = 0.3 mm) Faraday cups. Here, we describe the experimental setup and discuss how to achieve several requirements such as a large thermal load due to the {approx}40W of beam power.

  5. Effect of acetabular reinforcement ring with hook for acetabular dysplasia clarified by three-dimensional finite element analysis.

    PubMed

    Zhao, Xin; Chosa, Etsuo; Yamako, Go; Watanabe, Shinji; Deng, Gang; Totoribe, Koji

    2013-12-01

    The objective of this study was to biomechanically determine the effect of the severity of acetabular dysplasia, number and positions of screws and type of bone graft material used on the initial fixation strength of the acetabular reinforcement ring with hook (Ganz ring) using the finite element method. Relative micromotion increased as the severity of acetabular dysplasia increased and tended to decrease as the number of screws increased, but varied according to screw placement position. Increased strength of the bone graft material led to decreased relative micromotion. Biomechanically, the Ganz ring can be placed securely using 3 screws in patients with Crowe 1 dysplasia. However, in patients with Crowe 2 or higher dysplasia, it is necessary to spread at least 4 screws across an area of good host bone. PMID:23993349

  6. Migration of the Duraloc cup after 5 years.

    PubMed

    Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter; Windhager, Reinhard

    2008-12-01

    The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%). PMID:17609953

  7. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty.

    PubMed

    Zilkens, C; Djalali, S; Bittersohl, B; Kälicke, T; Kraft, C N; Krauspe, R; Jäger, Marcus

    2011-03-28

    The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA). One hundred and one (94.4 %) acetabular components did not show significant migration of more than 1 mm. Six (5.6%) implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous-coated acetabular components for primary THA does not prevent cup migration. PMID:21486725

  8. Exploring Volumetrically Indexed Cups

    ERIC Educational Resources Information Center

    Jones, Dustin L.

    2011-01-01

    This article was inspired by a set of 12 cylindrical cups, which are volumetrically indexed; that is to say, the volume of cup "n" is equal to "n" times the volume of cup 1. Various sets of volumetrically indexed cylindrical cups are explored. I demonstrate how this children's toy is ripe for mathematical investigation, with connections to…

  9. Acetabular rim and surface segmentation for hip surgery planning and dysplasia evaluation

    NASA Astrophysics Data System (ADS)

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Summers, Ronald M.; Ward, Michael M.

    2008-03-01

    Knowledge of the acetabular rim and surface can be invaluable for hip surgery planning and dysplasia evaluation. The acetabular rim can also be used as a landmark for registration purposes. At the present time acetabular features are mostly extracted manually at great cost of time and human labor. Using a recent level set algorithm that can evolve on the surface of a 3D object represented by a triangular mesh we automatically extracted rims and surfaces of acetabulae. The level set is guided by curvature features on the mesh. It can segment portions of a surface that are bounded by a line of extremal curvature (ridgeline or crestline). The rim of the acetabulum is such an extremal curvature line. Our material consists of eight hemi-pelvis surfaces. The algorithm is initiated by putting a small circle (level set seed) at the center of the acetabular surface. Because this surface distinctively has the form of a cup we were able to use the Shape Index feature to automatically extract an approximate center. The circle then expands and deforms so as to take the shape of the acetabular rim. The results were visually inspected. Only minor errors were detected. The algorithm also proved to be robust. Seed placement was satisfactory for the eight hemi-pelvis surfaces without changing any parameters. For the level set evolution we were able to use a single set of parameters for seven out of eight surfaces.

  10. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    PubMed

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. PMID:26343226

  11. Hydroxyapatite coating of an acetabular prosthesis. Effect on stability.

    PubMed

    Moilanen, T; Stocks, G W; Freeman, M A; Scott, G; Goodier, W D; Evans, S J

    1996-03-01

    We report the radiological and clinical outcome of a press-fit (SLF) acetabular component at two to three years in two groups of patients having primary total hip replacement. In 69 the implant was coated with hydroxyapatite (HA) and in 40 it was uncoated. The stability of the cup was assessed by measurement of proximal migration and change in the angle of inclination. The clinical results in the two groups did not differ significantly, and the mean proximal linear wear was similar in both. Fewer radiolucent lines (RLLs) were seen on the radiographs of cups coated with HA. The mean proximal migration was studied by calculating regression lines for each patient using migration measurements: for the SLF+HA group the mean slope was 0.06 mm/year and for the SLF-HA group 0.20 mm/year (p = 0.22). The change in the angle of inclination during follow-up was also consistently smaller in HA-coated cups. Using regression methods the SLF+HA group had a mean slope of 0.08 degrees/year and the SLF-HA group 0.44 degrees/year and the SLF-HA group 0.44 degrees/year (p = 0.023). Partial HA coating appeared to have no effect on the clinical outcome or on the rate of wear of polyethylene, but there was a trend towards a reduced rate of proximal migration, and a significant reduction in rotational migration and the number of radiolucent lines. This suggests that HA coating enhances the stability of this acetabular component. PMID:8666624

  12. Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population

    PubMed Central

    Xiao, Jian-Lin; Zuo, Jian-Lin; Liu, Peng; Qin, Yan-Guo; Li, Xue-Zhou; Liu, Tong; Gao, Zhong-Li

    2015-01-01

    Background: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. Methods: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. Results: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. Conclusions: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better. PMID:26063357

  13. Higher wear-rate of third-generation metal-backed Reflection cups with eto-sterilised UHMWPE at a mean 13 years follow-up.

    PubMed

    Hengst, David M; Thomsen, Per B; Homilius, Morten; Hansen, Torben B; Stilling, Maiken

    2014-12-01

    Polyethylene (PE) wear and osteolysis is a recognised problem with non-cross linked PE liners and first generation modular cup designs. Wear particles induce osteolysis leading to aseptic loosening. We retrospectively compared the linear PE wear and implant survival and revision rates of the Reflection Cup and the Duraloc 300. After a mean clinical follow-up of 13 years (range 11-15 years), the 2D linear PE wear-rate of the Reflection liner (n = 68) was 0.23 mm/year, with a mean total wear of 3.14 mm (1.04-7.36), SD 1.45. The wear-rate of the Duraloc 300 cups (n = 32) was 0.14 mm/year, with a mean total wear of 1.84 mm (0.55-4.63), SD 1.07. The difference in PE wear-rate as well as mean total wear was highly significant (p = 0.0001). There was a positive correlation between wear-rate and both Oxford Hip Score and Harris Hip Score (p = 0.02). Large acetabular cup size (>54 mm), HA coating on the stem and age <50 years did not influence PE wear. The higher wear-rate in the Reflection liners could be related to the EtO sterilisation. Intermediate and long-term follow-up is advisable. PMID:25096452

  14. Options for acetabular fixation surfaces.

    PubMed

    Klika, Alison K; Murray, Trevor G; Darwiche, Hussein; Barsoum, Wael K

    2007-01-01

    Aseptic loosening is the most common cause for revision total hip arthroplasty (THA). Due to poor long-term results with cemented acetabular components, cementless implants that rely on biologic fixation became popular in the United States for both primary and revision procedures in the early 1980s. Cementless acetabular components used in THA have been reported to have superior radiographic performance compared with cemented fixation, although the optimal method of acetabular fixation remains controversial. Cementless acetabular components require initial implant stability to allow for bone ingrowth and remodeling into the acetabular shell, providing long-term durability of the prosthesis. Many improved implant materials are available to facilitate bone growth and remodeling, including the 3 most common surface treatments; fibermesh, sintered beads, and plasma spray coatings. Recently added to these are porous metal surfaces, which have increased porosity and optimal pore sizes when compared with titanium fibermesh. The most studied of these materials is the titanium fibermesh fixation surface, which has demonstrated a mechanical failure rate of 1% at 10 to 15 years. This technology utilizes the diffusion bonding process to attach fiber metal pads to a titanium substrate using heat and pressure. The sintered bead fixation surface offers a porous coating of various sizes of spherical beads, achieved by the sintering process, and has been shown to provide long-term fixation. While there are less long-term published data regarding the titanium plasma spray surface, its early results have provided evidence of its durability, even in the face of significant osteolysis. The most recently added alternative fixation surface is porous tantalum metal, which offers potentially greater bone ingrowth and bone graft incorporation due to its high porosity (80%) and low modulus of elasticity (3 MPa). Porous tantalum implants have shown early favorable clinical results and have

  15. Uncemented Porous Tantalum Acetabular Components: Early Follow-Up and Failures in 599 Revision Total Hip Arthroplasties

    PubMed Central

    Long, William J.; Noiseux, Nicolas O.; Mabry, Tad M.; Hanssen, Arlen D.; Lewallen, David G.

    2015-01-01

    Background The purpose of this study was to determine the early outcomes of 599 cases of revision THA performed using a porous tantalum cup. Methods Clinical and radiographic data was sought in all patients at a minimum two years follow-up, after acetabular revision performed with a porous tantalum cup. Results Of the 599 cases identified, there were 51 re-operations in 47 patients (7.8 percent). Cup removal was required in 14 of these cases (2.3 percent). The most common cause for cup removal was a septic joint (12). No cups were revised for aseptic loosening during the study period. There was one case of early cup migration. There were 17 incomplete lucencies not initially seen on post-operative films, but identified later, all were non-progressive on subsequent x-rays. Conclusions Early results of porous tantalum acetabular components in the revision setting demonstrate good initial stability and low re-operation rates at two years follow-up. Level of Evidence Level 4: Case series PMID:26361451

  16. Exploring volumetrically indexed cups

    NASA Astrophysics Data System (ADS)

    Jones, Dustin L.

    2011-03-01

    This article was inspired by a set of 12 cylindrical cups, which are volumetrically indexed; that is to say, the volume of cup n is equal to n times the volume of cup 1. Various sets of volumetrically indexed cylindrical cups are explored. I demonstrate how this children's toy is ripe for mathematical investigation, with connections to geometry, algebra and differential calculus. Students with an understanding of these topics should be able to complete the analysis and related exercises contained herein.

  17. Long-term results of the threaded Mecron cup in primary total hip arthroplasty

    PubMed Central

    Clarius, Michael; Jung, Alexander W.; Streit, Marcus R.; Merle, Christian; Raiss, Patric

    2009-01-01

    In the 1970s, high failure rates of cemented acetabular components, especially in young patients, in the middle- and long-term prompted a search for alternatives. The Mecring was one of the most popular first generation uncemented, threaded cups widely used in the 1980s for arthroplasty of the hip. First generation threaded cups commonly had smooth surface treatment and showed unacceptably high failure rates in the mid-term. In a consecutive series of 209 patients, 221 threaded uncemented acetabular cups with smooth surface treatment (Mecring) had been implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. The mean time of follow-up was 17 (range 15–20) years. In 91 (41%) hips the acetabular component had been revised or was awaiting revision: two hips for infection and 84 (38%) for aseptic loosening. Five hips were awaiting revision. The survival rate for all revisions including hips awaiting revision was 49% (95% CI: 41–57%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. Patients with these components must be closely monitored as the failure rate remains high in the long-term. PMID:19629481

  18. Impaction grafted bone chip size effect on initial stability in an acetabular model: Mechanical evaluation

    PubMed Central

    Holton, Colin; Bobak, Peter; Wilcox, Ruth; Jin, Zhongmin

    2013-01-01

    Introduction Acetabular bone defect reconstruction is an increasing problem for surgeons with patients undergoing complex primary or revision total hip replacement surgery. Impaction bone grafting is one technique that has favourable long-term clinical outcome results for patients who undergo this reconstruction method for acetabular bone defects. Creating initial mechanical stability of the impaction bone graft in this technique is known to be the key factor in achieving a favourable implant survival rate. Different sizes of bone chips were used in this technique to investigate if the size of bone chips used affected initial mechanical stability of a reconstructed acetabulum. Methodology Twenty acetabular models were created in total. Five control models were created with a cemented cup in a normal acetabulum. Then five models in three different groups of bone chip size were constructed. The three groups had an acetabular protrusion defect reconstructed using either; 2–4 mm3, 10 mm3 or 20 mm3 bone chip size for impaction grafting reconstruction. The models underwent compression loading up to 9500 N and displacement within the acetabular model was measured indicating the initial mechanical stability. Results This study reveals that, although not statistically significant, the largest (20 mm3) bone chip size grafted models have an inferior maximum stiffness compared to the medium (10 mm3) bone chip size. Interpretations Our study suggests that 10 mm3 size of bone chips provide better initial mechanical stability compared to smaller or larger bone chips. We dismissed the previously held opinion that the biggest practically possible graft is best for acetabular bone graft impaction. PMID:24396238

  19. Ten-year results of a press-fit, porous-coated acetabular component.

    PubMed

    Grobler, G P; Learmonth, I D; Bernstein, B P; Dower, B J

    2005-06-01

    We retrospectively reviewed, ten years after surgery, 100 consecutive total hip replacements in which the Duraloc 300 cup had been used. Post-operative radiographs were analysed for placement of the cup and interface gaps and follow-up radiographs for lucent lines, osteolysis, wear and migration. All the components were found to be stable with no evidence of loosening. The mean rate of wear was 0.12 mm/year. Three hips developed acetabular osteolysis at the level of the apex hole. Two have successfully undergone bone grafting without removal of the implants and one patient is awaiting surgery. The Duraloc 300 cup has a survival of 100% at ten years with no aseptic loosening and a low incidence of pelvic osteolysis. PMID:15911659

  20. The role of cages in the management of severe acetabular bone defects at revision arthroplasty.

    PubMed

    Mäkinen, T J; Fichman, S G; Watts, E; Kuzyk, P R T; Safir, O A; Gross, A E

    2016-01-01

    An uncemented hemispherical acetabular component is the mainstay of acetabular revision and gives excellent long-term results. Occasionally, the degree of acetabular bone loss means that a hemispherical component will be unstable when sited in the correct anatomical location or there is minimal bleeding host bone left for biological fixation. On these occasions an alternative method of reconstruction has to be used. A major column structural allograft has been shown to restore the deficient bone stock to some degree, but it needs to be off-loaded with a reconstruction cage to prevent collapse of the graft. The use of porous metal augments is a promising method of overcoming some of the problems associated with structural allograft. If the defect is large, the augment needs to be protected by a cage to allow ingrowth to occur. Cup-cage reconstruction is an effective method of treating chronic pelvic discontinuity and large contained or uncontained bone defects. This paper presents the indications, surgical techniques and outcomes of various methods which use acetabular reconstruction cages for revision total hip arthroplasty. PMID:26733646

  1. Computer-Assisted Rotational Acetabular Osteotomy for Patients with Acetabular Dysplasia

    PubMed Central

    Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-01-01

    Rotational acetabular osteotomy (RAO) is a well-established surgical procedure for patients with acetabular dysplasia, and excellent long-term results have been reported. However, RAO is technically demanding and precise execution of this procedure requires experience with this surgery. The usefulness of computer navigation in RAO includes its ability to perform three-dimensional (3D) preoperative planning, enable safe osteotomy even with a poor visual field, reduce exposure to radiation from intraoperative fluoroscopy, and display the tip position of the chisel in real time, which is educationally useful as it allows staff other than the operator to follow the progress of the surgery. In our results comparing 23 hips that underwent RAO with navigation and 23 hips operated on without navigation, no significant difference in radiological assessment was observed. However, no perioperative complications were observed in the navigation group whereas one case of transient femoral nerve palsy was observed in non-navigation group. A more accurate and safer RAO can be performed using 3D preoperative planning and intraoperative assistance with a computed tomography-based navigation system. PMID:26929806

  2. A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature.

    PubMed

    Epinette, Jean-Alain; Manley, Michael T; D'Antonio, James A; Edidin, Avram A; Capello, William N

    2003-02-01

    We evaluated the clinical, radiographic, and survivorship outcomes in a series of 418 threaded hydroxyapatite-coated acetabular cups (Arc2f; Osteonics, Allendale, NJ) implanted in a consecutive series of 384 patients undergoing primary total hip arthroplasty. In all cases, the cup was screwed into the prepared acetabulum. Bone screws were used to provide secondary fixation. At a minimum 10-year follow-up, 304 cups were available for analysis. The cumulative survivorship (mechanical failure as endpoint) at that time was 99.43% +/- 0.0104. Two hundred seventy-six hips were available for full clinical and radiographic review at or after the tenth anniversary. No unstable implants were noted; all implant fixation interfaces were classified as "stable bone ingrown," and the cup migration rate was zero. Based on the survivorship achieved with this implant, our results compare favorably with survivorship reported for the best cemented and cementless acetabular implant designs. PMID:12629602

  3. Long-term results of the threaded Weill cup in primary total hip arthroplasty

    PubMed Central

    Clarius, Michael; Jung, Alexander W.; Raiss, Patric; Streit, Marcus R.; Merle, Christian

    2009-01-01

    Uncemented, threaded acetabular components with smooth surface treatment were widely used in continental Europe in the 1970s and 1980s for primary total hip arthroplasty (THA). Previously published studies showed high failure rates in the mid-term. In a consecutive series of 116 patients, 127 threaded cups with smooth surface treatment (Weill cup; Zimmer, Winterthur, Switzerland) were implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. Mean time of follow-up was 17 years (range 15–20). At the time of follow-up, the acetabular component had been revised or was awaiting revision in 30 hips (24%). Two hips were revised for infection and 23 for aseptic loosening. Four polyethylene liners were exchanged because of excessive wear. One hip was awaiting revision. The survival rate for all acetabular revisions including one hip awaiting revision was 75% (95%CI: 65–85%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. It is important to closely monitor patients with these components as the failure rate remains high in the long-term. PMID:19629480

  4. Good stability and minimal osteolysis with a biconical threaded cup at 10 years.

    PubMed

    Zweymüller, Karl A; Steindl, Martin; Schwarzinger, Ulrike

    2007-10-01

    In the literature there is no consensus on the value of threaded cementless cups. We primarily asked whether the newly constructed threaded double-cone cup without additional screw fixation would provide high survival at intermediate followup. We retrospectively reviewed 365 patients (376 hips) who underwent primary total hip arthroplasty using this cup made of pure titanium with ceramic-on-polyethylene articulating surfaces. At a minimum followup of 10.0 years (mean, 10.3 years; range, 10.0-13.1 years), 232 cups (61.7%) were available for analysis. We performed two revisions for early infection and cup breakage. No polyethylene liner was exchanged because of wear or instability. Three of the cup shells were radiographically loose at followup; one had periacetabular osteolysis. The mean liner wear rate was 0.13 mm per year. The Kaplan-Meier 10-year survivorship with revision of the cup shell for any reason was 99.3% (95% confidence interval, 96.9-99.8%) and with revision and radiographic loosening of the cup shell 98.6% (95% confidence interval, 96.0-99.5%). These intermediate results compare favorably with survivorship and periacetabular bone reaction data observed with the best cementless acetabular implant designs. PMID:17960675

  5. The Zweymüller threaded cup: a choice in revision? Migration analysis and follow-up after 6 years.

    PubMed

    Schröder, Jörg Hartmut; Matziolis, Georg; Tuischer, Jens; Leutloff, Dirk; Duda, Georg Norbert; Perka, Carsten

    2006-06-01

    Excellent long-term results are reported for threaded cups with an osteointegrable surface in primary interventions. So far, little data are available on the use of such implants in revision cases. We investigated 30 loosened Aesculap PM threaded cups (Tuttlingen, Germany) with a smooth surface, revised with a conical, corundum-blasted Zweymüller threaded cup (Zweymüller Alloclassic CSF cup, Zimmer, Warsaw, Ind). Aseptic radiological loosening was seen in 8% of cases, and a survival rate of 95% was achieved after 6.1 years. Average migration was 1.4 mm cranially and 0.7 mm medially. The Harris hip score improved from 42 points preoperatively to 75 points at follow-up. Good medium-term results are possible after revision using a threaded cup with an osteointegrable surface, but not if segmental acetabular margin defects are present. PMID:16781400

  6. Bleeding and cupping.

    PubMed Central

    Turk, J. L.; Allen, E.

    1983-01-01

    Bleeding and cupping have been used in medicine since ancient times in the treatment of fevers and local inflammatory disorders. Local bleeding, by 'wet cupping', was effected by a scarificator or by leeches. John Hunter recommended venesection in moderation but preferred leeches for local bleeding. Bleeding as an accepted therapeutic practice went out of vogue in the middle of the nineteenth century as a result of the introduction of modern scientific methods. Dry cupping and the use of leeches, as counter irritants, persisted until the middle of this century. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:6338802

  7. Mid-term clinical results of total hip arthroplasty using a Wagner standard cup for dysplastic hip

    PubMed Central

    Maezawa, Katsuhiko; Nozawa, Masahiko; Yuasa, Takahito; Aritomi, Kentaro; Ogawa, Seiki; Maruyama, Yuichiro; Kaneko, Kazuo

    2014-01-01

    Background The outcome of cementless total hip arthroplasty depends on many factors. We must not forget fundamental things those are design of outer surface of the component, that leads bone ingrowth into the prosthesis, better initial stability, and better insertional techniques. The purpose of this study was to review our experience with metal-on-metal total hip arthroplasty with a Wagner standard cup for patients who had acetabular dysplasia. Patients and methods Fifty-four patients with 55 hips underwent primary metal-on-metal total hip arthroplasty (Metasul prosthesis) with a Wagner standard cup (44–48 mm in outer diameter) and were followed for a minimum of 10 years. All patients received the same type of cementless femoral component (Natural hip stem) and femoral head (28 mm in diameter). Results Seventeen of the 55 Wagner standard cups (30.9%) showed aseptic loosening over a mean period of 3.6 years after surgery, and there were no bone anchors on the outer surface of the 16 retrieved cups. Conclusion From our experience, the small Wagner standard cup does not achieve sufficient osteointegration and we do not recommend the use of this cup, especially for patients with acetabular dysplasia and/or those with a small stature. PMID:25561751

  8. Management of an Open Acetabular Fracture in a Skeletally Immature Patient

    PubMed Central

    Clutter, Sarah Y; Morgan, Steven J; Erickson, Mark; Smith, Wade R; Stahel, Philip F

    2007-01-01

    Background: Open acetabular fractures in children are rare, but potentially devastating injuries. Secondary to the low incidence, there is an apparent lack of reports on appropriate management strategies for open pediatric acetabular fractures in the literature. Methods: Description of a case study. Results: A 3 years and ten months-old girl was ejected as a passenger from an all terrain vehicle. She sustained a displaced, grade IIIA open left anterior column acetabular fracture. The injury was treated by extending the open wound to a formal first window of the ilioinguinal approach. After surgical debridement, the anterior column was reduced anatomically and fixed by two lag screws which avoided the tri-radiate cartilage. A vaginal laceration was debrided and repaired. The patient was treated in a spica cast without weight bearing on the left lower extremity for 8 weeks. No perioperative complications occurred. The acetabular fracture healed in an anatomic position within 8 weeks. To avoid premature closure of the tri-radiate cartilage, the patient underwent a physeal bar resection at one year after injury. At two-year follow up, she was walking and running without pain and had a free range of motion of her left hip. Conclusions: Operative management should represent the therapy of choice for open, displaced pediatric acetabular fractures. After fracture healing, a scheduled physeal bar resection may be required for injuries which involve the tri-radiate cartilage. PMID:19461903

  9. Revision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study

    PubMed Central

    Jeong, Min; Kim, Hyung-Joo; Lim, Seung-Jae; Moon, Young-Wan

    2016-01-01

    Purpose The purpose of this study is to report the short-term outcomes of revision total hip arthroplasty (THA) using tantalum augments in patients with severe acetabular bone defects. Materials and Methods We retrospectively analyzed 15 revision THAs performed in 15 patients using tantalum augments between June 2010 and December 2013. Acetabular bone defects were Paprosky type IIIA in 7 hips, type IIIB in 7, and type IV in 1. The causes of revision surgery were aseptic loosening in 12 hips and deep infection in 3. Revisions were first in 1 hip, second in 3, and third in 11. Six patients were male and 9 female with a mean age of 59 years (range, 48-75 years). Mean follow-up was 29 months (range, 24-48 months). Results Mean Harris hip score was improved from 34 points (range, 12-54 points) preoperatively to 84 points (range, 38-90 points) at final follow-up. On the final follow-up radiographs, there were 12 hips (80.0%) with stable fixation of the acetabular cup, 2 (13.3%) with secondary stability after mild acetabular protrusion, and 1 (6.7%) with radiolucency around the acetabular cup without mechanical symptoms. Complications included one patient with acute hematogenous infection managed by surgical debridement and long-term antibiotic therapy. There were no cases with nerve palsy or dislocation during the follow-up period. Conclusion The present study showed satisfactory clinical and radiographic outcomes of revision THA using tantalum augments due to severe acetabular bone defects of Paprosky type III or IV at a minimum follow-up of 2 years. PMID:27536651

  10. The use of fibre-based demineralised bone matrix in major acetabular reconstruction: surgical technique and preliminary results

    PubMed Central

    Karoubi, Mathieu; Dumaine, Valérie; Courpied, Jean Pierre

    2010-01-01

    Acetabular osteolysis associated with socket loosening is one of the main long-term complications of total hip arthroplasty. In case of major bone loss, where <50% host bone coverage can be obtained with a porous-coated cementless cup, it is generally agreed that a metal ring or cage in association with a cemented component and allograft bone should be used. In order to promote allograft bone consolidation and incorporation, we have associated demineralised bone matrix (DBM, Grafton® A Flex) to the construct ion. Here we describe the technical details of major acetabular reconstruction using the Kerboull acetabular reinforcement device with allograft bone and DBM. This device has a hook that must be placed under the teardrop of the acetabulum and a plate for iliac fixation. The main advantages of this device are help in restoring the normal centre of hip rotation, guiding the reconstruction and partially unloading the graft. The Kerboull acetabular reinforcement device has provided a 92% survival rate free of loosening at 13-year follow-up in a consecutive series of 60 type III and IV deficiencies. Our preliminary results using DBM indicate faster allograft consolidation and remodelling. PMID:21057788

  11. Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation.

    PubMed

    Engh, Charles A; Hopper, Robert H; Engh, C Anderson

    2004-10-01

    This study examined the long-term outcome of a single institution's experience with 4,289 primary total hip arthroplasties using hemispheric porous-coated cups. Initial fixation was achieved with spikes (255 AML TriSpike cups), by press-fitting with rim screws (427 Arthropor cups) or by press-fitting the component (83 Harris-Galante, 391 ACS Triloc+, 2,537 Duraloc, and 596 Pinnacle cups). Among 203 revised hips, only 18 cups were found to be loose at the time of revision. Using revision for any reason as an end point, 15-year survivorship was 82.9% +/- 5.6% (95% confidence interval) for spiked components, 71.6% +/- 8.5% for press-fit cups with adjunctive rim screws, and 72.0% +/- 12.6% for press-fit components (P<.001, log rank). Using revision for aseptic loosening as an end point, 15-year survivorship was 94.7% +/- 3.4% for spiked cups, 98.4% +/- 1.9% for press-fit cups with screws and 100% +/- 0.1% for press-fit cups. Despite an increasing incidence of polyethylene wear-related revisions, porous-coated acetabular components have demonstrated excellent long-term fixation. PMID:15457419

  12. Explicit finite element modelling of the impaction of metal press-fit acetabular components.

    PubMed

    Hothi, H S; Busfield, J J C; Shelton, J C

    2011-03-01

    Metal press-fit cups and shells are widely used in hip resurfacing and total hip replacement procedures. These acetabular components are inserted into a reamed acetabula cavity by either impacting their inner polar surface (shells) or outer rim (cups). Two-dimensional explicit dynamics axisymmetric finite element models were developed to simulate these impaction methods. Greater impact velocities were needed to insert the components when the interference fit was increased; a minimum velocity of 2 m/s was required to fully seat a component with a 2 mm interference between the bone and outer diameter. Changing the component material from cobalt-chromium to titanium alloy resulted in a reduction in the number of impacts on the pole to seat it from 14 to nine. Of greatest significance, it was found that locking a rigid cap to the cup or shell rim resulted in up to nine fewer impactions being necessary to seat it than impacting directly on the polar surface or using a cap free from the rim of the component, as is the case with many commercial resurfacing cup impaction devices currently used. This is important to impactor design and could make insertion easier and also reduce acetabula bone damage. PMID:21485331

  13. A multiplanar radiography method for assessing cup orientation in total hip arthroplasty.

    PubMed

    Amiri, Shahram; Masri, Bassam A; Garbuz, Donald; Anglin, Carolyn; Wilson, David R

    2012-10-01

    Correct orientation of the acetabular cup considering patient-specific functional pelvic angles is an important factor for improving outcomes and avoiding complications after total hip arthroplasty. This study introduces a new, noninvasive radiographic tool for accurately determining a patient's specific pelvic tilt angle preoperatively, as well as accurately assessing acetabular cup orientation with respect to bony landmarks intraoperatively and postoperatively. The method was validated by imaging a bone replica model of the pelvis with implanted hip components, in comparison to digitized references, and verified with a cadaveric specimen. Pelvic tilt was measured with an accuracy of 0.1 deg and SD of 0.4 deg. Operative cup inclination and anteversion showed accuracies of 0.6 deg and 2.5 deg, with SD of 0.4 deg and 0.6 deg, respectively; these could be improved further by subtracting systematic bias. The method shows accuracy advantages over existing radiographic and fluoroscopic methods and exposes the subjects to a lower radiation dose compared to the similar computed tomography methods. These results suggest that the proposed method is feasible for assessing cup placement with reference to the functional and anatomical references. Furthermore, the ability to reference the same bony landmarks preoperatively, intraoperatively, and postoperatively has important research and clinical advantages. PMID:23083199

  14. Cementless cup fixation in total hip arthroplasty after 5-8 years.

    PubMed

    Spicer, D D; Schaper, L A; Pomeroy, D L; Badenhausen, W E; Curry, J I; Suthers, K E; Smith, M W

    2001-01-01

    A series of 199 total hip arthroplasties was performed using a porous-coated, hemispherical press-fit acetabular cup. At a mean follow-up of 91.5 months 158 cups were available for clinical and radiological review. The mean age of the patients at the time of the index arthroplasty was 62.5 years. The mean Harris Hip score at final follow-up was 87.3. No shells were revised although eccentric polyethylene wear prompted liner replacement in two cases. Osteolysis was noted in six cases but predominantly in relation to the femoral stem. Focal pelvic osteolytic lesions were rare. All the cups were classified as stable on radiography. PMID:11794260

  15. Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

    PubMed Central

    Sanz-Andrés, Ángel; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance. PMID:25110735

  16. Mathematical analysis of the effect of rotor geometry on cup anemometer response.

    PubMed

    Sanz-Andrés, Ángel; Pindado, Santiago; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance. PMID:25110735

  17. Osteopathic diagnosis of an acetabular injury.

    PubMed

    Morthland, Tim; Cote, Nicholas S; Humphrey, Jon; Fulk, Doug

    2010-05-01

    Physical findings demarking pathologic somatovisceral reflex activity and fascial strain patterns may lead the osteopathic physician to diagnoses that are masked within the initial presentation of a patient. The authors present a case report that demonstrates the use of osteopathic principles in the diagnosis of a chronic acetabular fracture and acetabular labral tear in a 19-year-old man. The injuries resulted from a posterior hip dislocation sustained during a basketball game more than 1 year before presentation. Osteopathic manipulative treatment and diagnostic techniques also relieved the patient's persistent thoracic pain, nausea, and vomiting. Subsequent orthopedic repair had the potential to avert or delay degenerative hip disease in the patient. PMID:20538751

  18. Complementary Coffee Cups

    ERIC Educational Resources Information Center

    Banchoff, Thomas

    2006-01-01

    What may have been the birth of a new calculus problem took place when the author noticed that two coffee cups, one convex and one concave, fit nicely together, and he wondered which held more coffee. The fact that their volumes were about equal led to the topic of this article: complementary surfaces of revolution with equal volumes.

  19. Cups and Downs

    ERIC Educational Resources Information Center

    Stewart, Ian

    2012-01-01

    Martin Gardner wrote about a coin-flipping trick, performed by a blindfolded magician. The paper analyses this trick, and compares it with a similar trick using three cups flipped in pairs. Several different methods of analysis are discussed, including a graphical analysis of the state space and a representation in terms of a matrix. These methods…

  20. Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup.

    PubMed

    Berli, Bernhard J; Ping, Gu; Dick, Walter; Morscher, Erwin W

    2007-08-01

    The key rationale for a nonmodular flexible press-fit cup was to maximize long-term stability with a cementless, porous metal-coated cup that is low in stiffness (no metal shell) and to achieve fixation solely through biradial eccentricity between the cup and the acetabular cavity. We asked whether the promising results achieved at 5 and 10 years would be maintained at 15 years. We reviewed 261 patients who received the first 280 Morscher Press-Fit Cups. One hundred twenty patients (126 hips) died. One hundred one patients (112 hips) had a clinical and radiographic followup after a minimum of 13.5 years (mean, 14.7 years; range, 13.5-17.0 years). Twenty-four patients with 26 hips were clinically examined or interviewed by telephone. Three of the 101 patients were lost to followup. We judged the results excellent or good in 96% of the hips. The 15-year overall survivorship was 95.3% and with the end point of aseptic loosening, the survivorship was 97.5%. Wear was greater in cups with an inclination greater than 45 degrees and in metal-polyethylene pairings compared with ceramic-polyethylene pairings. This cup design performs well over the long term. PMID:17415011

  1. Evaluation of ranges of motion of a new constrained acetabular prosthesis for canine total hip replacement

    PubMed Central

    2013-01-01

    Background Total hip replacement (THR) is considered to be the most effective treatment option for advanced osteoarthritis of the hip in large breed dogs. However, a proportion of post-THR patients suffer prosthesis dislocation for various reasons, which may be addressed by a constrained acetabular prosthesis design. The study proposed a new THR with constrained acetabular component that aimed to decrease the incidence of postoperative dislocation while maintaining the necessary range of motion (ROM); and, through computer-simulated implantations, evaluated the ROM of the THR with and without malpositioning of the acetabular component. Methods A new THR with a constrained acetabular component that had an inward eccentric lining and a 60° cut-out on the dorsal side was designed, and its computer-aided design models were implanted into the pelvic and femoral models reconstructed from the computed tomography data of six healthy Labrador Retriever dogs. The allowable and functional ROM of the implanted THR were determined via computer simulations. The contact patterns between the bone or the prosthetic components at extreme positions of the THR were analyzed. Influence of malpositioning of the acetabular component on the ROM was assessed. Results The means (SD) of the functional ranges for flexion, extension, adduction, abduction, internal rotation and external rotation were 51.8° (6.6°), 163.3° (7.3°), 33.5° (5.7°), 74.0° (3.7°), 41.5° (8.3°) and 65.2° (9.9°), respectively. Malpositioning of the acetabular component by 20° in one direction was found to reduce ROM in other directions (reducing lateral opening: flexion: 12°, adduction: 20°, internal/external rotations: < 20°; increasing lateral opening: extension and abduction: < 16°; reducing retroversion: extension: < 20°, abduction: 15°, external rotation: < 20°; increasing retroversion: flexion: < 20°, abduction, adduction and internal rotation: 20°). Conclusions From the computer

  2. Miniature modified Faraday cup for micro electron beams

    DOEpatents

    Teruya, Alan T.; Elmer, John W.; Palmer, Todd A.; Walton, Chris C.

    2008-05-27

    A micro beam Faraday cup assembly includes a refractory metal layer with an odd number of thin, radially positioned traces in this refractory metal layer. Some of the radially positioned traces are located at the edge of the micro modified Faraday cup body and some of the radially positioned traces are located in the central portion of the micro modified Faraday cup body. Each set of traces is connected to a separate data acquisition channel to form multiple independent diagnostic networks. The data obtained from the two diagnostic networks are combined and inputted into a computed tomography algorithm to reconstruct the beam shape, size, and power density distribution.

  3. The effect of the Rim Cutter on cement pressurization and penetration on cemented acetabular fixation in total hip arthroplasty: an in vitro study.

    PubMed

    Smith, B N; Lee, A J C; Timperley, A J; Whitehouse, S L; Crawford, R W

    2010-01-01

    The Rim Cutter (Stryker Orthopedics, Mahwah, New Jersey) is a tool designed to cut a ledge inside the rim of the acetabulum, onto which a precisely trimmed, cemented, flanged cup can be fitted. The aim was to investigate the effect of the Rim Cutter on the intra-acetabular cement mantle pressure and the depth of cement penetration during cup insertion. The study had two parts. In the first part, hemi-pelvis models were fitted with pressure sensors. Pressure in the acetabulum was measured on insertion of a conventional cemented flanged cup with and without the use of a Rim Cutter to prepare the rim of the acetabulum. The second part assessed cement penetration when the same cups were inserted into a foam shell model. The shell was mounted in a jig and had holes drilled in it; the distance that cement penetrated into the holes was measured. A significant increase in cement pressure at the apex (p = 0.04) and the rim (p = 0.004) is seen when the Rim Cutter is used. Cement penetration in the Rim Cutter group was significantly increased at the rim of the acetabulum (p = 0.003). Insertion of a flanged cup after the acetabulum is prepared with the Rim Cutter leads to a significant increase in cement pressure and penetration during cup insertion in vitro when compared with conventional flanged cups. PMID:21053777

  4. Modified Faraday cup

    DOEpatents

    Elmer, John W.; Teruya, Alan T.; O'Brien, Dennis W.

    1996-01-01

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0.degree. to 360.degree. and the waveforms are recorded by a digitizing storage oscilloscope. Two-din-tensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment.

  5. Modified Faraday cup

    DOEpatents

    Elmer, J.W.; Teruya, A.T.; O`Brien, D.W.

    1996-09-10

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams is disclosed. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees from 0{degree} to 360{degree} and the waveforms are recorded by a digitizing storage oscilloscope. Two-dimensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment. 12 figs.

  6. Meralgia Paresthetica and Femoral Acetabular Impingement: A Possible Association

    PubMed Central

    Ahmed, Aiesha

    2010-01-01

    Meralgia paresthetica consists of pain and dysesthesia in the anterolateral thigh. Etiology is divided into spontaneous and iatrogenic causes. To my knowledge this has never been attributed to femoral acetabular impingement. This case highlights the presence of lateral femoral cutaneous neuropathy in the setting of femoral acetabular impingement syndrome thus raising the possibility of an association. Keywords Femoral acetabular impingement; Lateral femoral cutaneous nerve; Dysesthesia; Nerve conduction studies PMID:22043261

  7. Primary stability of two uncemented acetabular components of different geometry: hemispherical or peripherally enhanced?

    PubMed Central

    Antoniades, G.; Smith, E. J.; Deakin, A. H.; Wearing, S. C.; Sarungi, M.

    2013-01-01

    Objective This study compared the primary stability of two commercially available acetabular components from the same manufacturer, which differ only in geometry; a hemispherical and a peripherally enhanced design (peripheral self-locking (PSL)). The objective was to determine whether altered geometry resulted in better primary stability. Methods Acetabular components were seated with 0.8 mm to 2 mm interference fits in reamed polyethylene bone substrate of two different densities (0.22 g/cm3 and 0.45 g/cm3). The primary stability of each component design was investigated by measuring the peak failure load during uniaxial pull-out and tangential lever-out tests. Results There was no statistically significant difference in seating force (p = 0.104) or primary stability (pull-out p = 0.171, lever-out p = 0.087) of the two components in the low-density substrate. Similarly, in the high-density substrate, there was no statistically significant difference in the peak pull-out force (p = 0.154) or lever-out moment (p = 0.574) between the designs. However, the PSL component required a significantly higher seating force than the hemispherical cup in the high-density bone analogue (p = 0.006). Conclusions Higher seating forces associated with the PSL design may result in inadequate seating and increased risk of component malpositioning or acetabular fracture in the intra-operative setting in high-density bone stock. Our results, if translated clinically, suggest that a purely hemispherical geometry may have an advantage over a peripherally enhanced geometry in high density bone stock. Cite this article: Bone Joint Res 2013;2:264–9. PMID:24326398

  8. ION PRODUCING MECHANISM (CHARGE CUPS)

    DOEpatents

    Brobeck, W.W.

    1959-04-21

    The problems of confining a charge material in a calutron and uniformly distributing heat to the charge is described. The charge is held in a cup of thermally conductive material removably disposed within the charge chamber of the ion source block. A central thermally conducting stem is incorporated within the cup for conducting heat to the central portion of the charge contained within the cup.

  9. Longevity® constrained cup: an operative technical tip for prevention of metallic ring disassembly.

    PubMed

    Ferrero Manzanal, Francisco; Murcia Asensio, Antonio; Lax Pérez, Raquel; Gil Gómez, José Eduardo; Fernández Fairén, Mariano

    2016-01-01

    Constrained liners are a salvage procedure for treating or preventing recurrent dislocations. The Longevity® constrained liner (Zimmer) has a special design with cut-outs on its circumference for avoiding impingement in certain areas and a metallic constraining ring that has to be impacted. The ring impaction may be technical demanding. We recommend preassembly with the head component prior to seating into the acetabular cup, thus avoiding the soft tissue or cement interference and malposition due to bad angle of incidence of impaction force. PMID:26980240

  10. Gordon Bennett Airplane Cup

    NASA Technical Reports Server (NTRS)

    Margoulis, W

    1921-01-01

    The characteristics of the airplanes built for the Gordon Bennet Airplane Cup race that took place on September 28, 1920 are described. The airplanes are discussed from a aerodynamical point of view, with a number of new details concerning the French machines. Also discussed is the regulation of future races. The author argues that there should be no limitations on the power of the aircraft engines. He reasons that in the present state of things, liberty with regard to engine power does not lead to a search for the most powerful engine, but for one which is reliable and light, thus leading to progress.

  11. Cup Cylindrical Waveguide Antenna

    NASA Technical Reports Server (NTRS)

    Acosta, Roberto J.; Darby, William G.; Kory, Carol L.; Lambert, Kevin M.; Breen, Daniel P.

    2008-01-01

    The cup cylindrical waveguide antenna (CCWA) is a short backfire microwave antenna capable of simultaneously supporting the transmission or reception of two distinct signals having opposite circular polarizations. Short backfire antennas are widely used in mobile/satellite communications, tracking, telemetry, and wireless local area networks because of their compactness and excellent radiation characteristics. A typical prior short backfire antenna contains a half-wavelength dipole excitation element for linear polarization or crossed half-wavelength dipole elements for circular polarization. In order to achieve simultaneous dual circular polarization, it would be necessary to integrate, into the antenna feed structure, a network of hybrid components, which would introduce significant losses. The CCWA embodies an alternate approach that entails relatively low losses and affords the additional advantage of compactness. The CCWA includes a circular cylindrical cup, a circular disk subreflector, and a circular waveguide that serves as the excitation element. The components that make it possible to obtain simultaneous dual circular polarization are integrated into the circular waveguide. These components are a sixpost polarizer and an orthomode transducer (OMT) with two orthogonal coaxial ports. The overall length of the OMT and polarizer (for the nominal middle design frequency of 2.25 GHz) is about 11 in. (approximately equal to 28 cm), whereas the length of a commercially available OMT and polarizer for the same frequency is about 32 in. (approximately equal to 81 cm).

  12. World Cup Hopes

    NASA Technical Reports Server (NTRS)

    2002-01-01

    From May 31 to June 30 the biggest single-sport event in the world, the 2002 FIFA World Cup (tm), will be taking place in Asia. South Korea and Japan are acting as hosts for the event which is being held in Asia for the first time. This true-color image of the southern Korean peninsula and southern Japan was acquired on May 25, 2002, by the Moderate-resolution Imaging Spectroradiometer (MODIS), flying aboard NASA's Terra satellite. Thirty-two nations are represented at this year's Finals including the 1998 champion France, European powers England and Italy, tournament favorite Argentina, and the United States. The finals are the culmination of a 2-year qualifying process which started with 132 nations competing in regional qualification tournaments. In the round-robin first round of the World Cup, the U.S. team will be competing against teams from Portugal, Poland, and South Korea. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC

  13. Welding torch gas cup extension

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S. (Inventor)

    1988-01-01

    The invention relates to a gas shielded electric arc welding torch having a detachable gas cup extension which may be of any desired configuration or length. The gas cup extension assembly is mounted on a standard electric welding torch gas cup to enable welding in areas with limited access. The gas cup assembly has an upper tubular insert that fits within the gas cup such that its lower portion protrudes thereform and has a lower tubular extension that is screwed into the lower portion. The extension has a rim to define the outer perimeter of the seat edge about its entrance opening so a gasket may be placed to effect an airtight seal between the gas cup and extension. The tubular extension may be made of metal or cermaic material that can be machined. The novelty lies in the use of an extension assembly for a standard gas cup of an electric arc welding torch which extension assembly is detachable permitting the use of a number of extensions which may be of different configurations and materials and yet fit the standard gas cup.

  14. Unusual Cause of Hip Pain: Intrusion of the Acetabular Labrum

    PubMed Central

    Jang, Se-Ang; Byun, Young-Soo; Jeong, Dae-Geun; Han, In-Ho; Kim, Min-Guek

    2015-01-01

    Femoroacetabular impingement and dysplatic hip joint is well known cause of osteoarthritis. In these diseases, labral tear and subsequent cartilage damage is thought to be main pathophysiology of development of osteoarthritis. If there are no known bony abnormalities, we called it as idiopathic osteoarthritis. Normal appearance of acetabular labrum is a continuous, usually triangular structure that attaches to the bony rim of the acetabulum and is completed at the inferior portion by the transverse acetabular ligament over the acetabular notch. A few authors reported intra-articular labrum and its relation to the development of osteoarthritis. But they didn't comment the primary bony abnormality especially acetabulum. We'd like to report x-ray, computed tomogram, magnetic resonance arthrogram and arthroscopic findings of a case had double contour sign of acetabular dome combined with intrusion of acetabular labrum.

  15. The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.

    PubMed

    Lachiewicz, P F; Watters, T S

    2016-01-01

    The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. PMID:26733644

  16. The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning.

    PubMed

    Maruyama, M; Feinberg, J R; Capello, W N; D'Antonio, J A

    2001-12-01

    Morphologic features of the hips, in particular those features germane to determination of acetabular and femoral anteversion angles and femoral head offset, were studied in 50 male and 50 female human skeletons with bilateral normal joints. Four distinct configurations were identified relative to the anterior acetabular ridge. The majority (121, 60.5%) were curved; 51 (25.5%) were angular; 19 (9.5%) were irregular; and nine (4.5%) were straight. The acetabular anteversion angle measured 19.9 degrees +/- 6.6 degrees (range, 7 degrees-42 degrees) and was significantly larger in females (21.3 degrees +/- 7.1 degrees) versus males (18.5 degrees +/- 5.8 degrees). The notch acetabular angle, which can be identified easily intraoperatively, was defined as the angle created at the intersection of a line from the sciatic notch along the posterior acetabular ridge and a line from the posterior to the anterior acetabular wall. This angle is almost perpendicular (89.0 degrees +/- 3.5 degrees) and, therefore, may provide an accurate estimate of acetabular anteversion during cup placement. Awareness of the anatomic differences between genders for acetabular anteversion angle, anterolateral bowing of the femur, and neck shaft angle may help reduce the relatively higher incidence of dislocation in females and may lead to different implant designs for male and female patients. PMID:11764371

  17. [Analysis of the Basic Stress Pathway Above Acetabular Dome].

    PubMed

    Nie, Yong; Ma, Jun; Haung, Qiang; Hu, Qinsheng; Shi, Xiaojun; Pei, Fuxing

    2015-08-01

    The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in acetabular reconstruction of total hip arthroplasty (THA). The purpose of this study was to describe the basic stress pathway to provide evidence for clinical acetabular reconstruction guidance of THA. A subject-specific finite element (FE) model was developed from CT data to generate 3 normal hip models and a convergence study was conducted to determine the number of pelvic trabecular bone material properties using 5 material assignment plans. In addition, in the range of 0 to 20 mm above the acetabular dome, the models were sectioned and the stress pathway was defined as two parts, i.e., 3D, trabecular bone stress distribution and quantified cortical bone stress level. The results showed that using 100 materials to define the material property of pelvic trabecular bone could assure both the accuracy and efficiency of the FE model. Under the same body weight condition, the 3D trabecular bone stress distributions above the acetabular dome were consistent, and especially the quantified cortical bone stress levels were all above 20 MPa and showed no statistically significant difference (P>0.05). Therefore, defining the basic stress pathway above the acetabular dome under certain body weight condition contributes to design accurate preoperative plan for acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants. PMID:26710451

  18. Hemispheric titanium porous coated acetabular component without screw fixation.

    PubMed

    Dorr, L D; Wan, Z; Cohen, J

    1998-06-01

    One hundred fifteen hips in 108 patients with primary total hip arthroplasty using the anatomic porous replacement hemispheric acetabular component implanted without adjunctive screw fixation had a mean postoperative followup time of 6 years (range, 5-7.4 years). Clinical evaluation was performed using the Harris hip score and patient self assessment using a modified Short Form-36 questionnaire. Radiographs were measured for radiolucent lines, polyethylene wear, osteolysis, migration, and fractures. No acetabular metal shell had been revised for loosening or was radiographically loose with or without migration (more than 3 mm) at final followup. Reoperation was done in nine (8%) hips because of polyethylene insert wear or disassembly. No fracture of the acetabular bone occurred at the time of surgery or was observed on radiograph. Fixation of the metal shell was stable, with progressive radiolucent lines observed at final followup in 2% of the hips. Osteolysis was recorded in one patient with two acetabular components. The fixation of noncemented hemispheric porous coated acetabular components is more related to the technique of acetabular bone preparation and press fit implantation than to whether additional screws or peg fixation are used. Fixation of this acetabular component without screws at an average of 6 years after surgery is reproducible and predictable in primary hip arthroplasty. The design of modular polyethylene inserts has been improved and should reduce the wear rate of reoperations of the polyethylene insert. PMID:9646758

  19. Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?

    PubMed Central

    Wu, Yong-De; Cai, Xian-Hua; Liu, Xi-Ming; Zhang, Hong-Xi

    2013-01-01

    OBJECTIVE: The acetabular buttress-plate has been widely used in treating difficult cases with satisfying clinical results. However, the biomechanical properties of a postoperative acetabular fracture fixed by the buttress-plate are not clear. The purpose of this study was to evaluate the biomechanical properties of stability after the anterior tube buttress-plate fixation of complex acetabular fractures in the quadrilateral area. METHODS: A construct was proposed based on anterior construct plate - 1/3 tube buttress plate fixation for acetabular both-column fractures. Two groups of six formalin-preserved cadaveric pelvises were analyzed: (1) group A, the normal pelvis and (2) group B, anterior construct plate-1/3 tube buttress plate with quadrilateral area fixation. The displacements were measured, and cyclical loads were applied in both standing and sitting simulations. RESULTS: As the load was added, the displacements were Aposition: p = 0.013; sitting position: p = 0.009) between groups A and B. CONCLUSION: The anterior construct plate - 1/3 tube buttress plate fixation provided a better stable construct for early sitting. The standing mode yielded more significant differences between the groups. Placing a 1/3 tube buttress-plate via an anterior approach is a novel method of providing quadrilateral area support in this setting. PMID:23917670

  20. On Cup Anemometer Rotor Aerodynamics

    PubMed Central

    Pindado, Santiago; Pérez, Javier; Avila-Sanchez, Sergio

    2012-01-01

    The influence of anemometer rotor shape parameters, such as the cups' front area or their center rotation radius on the anemometer's performance was analyzed. This analysis was based on calibrations performed on two different anemometers (one based on magnet system output signal, and the other one based on an opto-electronic system output signal), tested with 21 different rotors. The results were compared to the ones resulting from classical analytical models. The results clearly showed a linear dependency of both calibration constants, the slope and the offset, on the cups' center rotation radius, the influence of the front area of the cups also being observed. The analytical model of Kondo et al. was proved to be accurate if it is based on precise data related to the aerodynamic behavior of a rotor's cup. PMID:22778638

  1. Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press-fit implantation.

    PubMed

    Ong, Kevin L; Rundell, Steve; Liepins, Imants; Laurent, Ryan; Markel, David; Kurtz, Steven M

    2009-11-01

    Press-fit implantation may result in acetabular component deformation between the ischial-ilial columns ("pinching"). The biomechanical and clinical consequences of liner pinching due to press-fit implantation have not been well studied. We compared the effects of pinching on the polyethylene fracture risk, potential wear rate, and stresses for two different thickness liners using computational methods. Line-to-line ("no pinch") reaming and 2 mm underreaming press fit ("pinch") conditions were examined for Trident cups with X3 polyethylene liner wall thicknesses of 5.9 mm (36E) and 3.8 mm (40E). Press-fit cup deformations were measured from a foam block configuration. A hybrid material model, calibrated to experimentally determined stress-strain behavior of sequentially annealed polyethylene, was applied to the computational model. Molecular chain stretch did not exceed the fracture threshold in any cases. Nominal shell pinch of 0.28 mm was estimated to increase the volumetric wear rate by 70% for both cups and peak contact stresses by 140 and 170% for the 5.9 and 3.8 mm-thick liners, respectively. Although pinching increases liner stresses, polyethylene fracture is highly unlikely, and the volumetric wear rates are likely to be low compared to conventional polyethylene. PMID:19489047

  2. Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA.

    PubMed

    Röhrl, Stephan M; Nivbrant, Bosse; Ström, Håkan; Nilsson, Kjell G

    2004-12-01

    To evaluate different modes of cementless fixation of hemispherical cups, we operated on 87 hips in 81 patients using 4 different means of cup fixation. The hips were randomly assigned to fixation with press-fit technique only (PF), or with augmentation with screws (S), pegs (P), or hydroxyapatite (HA) coating. The patients were evaluated with radiostereometric analysis (RSA) for cup migration and wear, conventional radiography for osteolysis, and Harris Hip Score for clinical outcome over 5 years. The fixation of the cups did not differ between the groups, but HA showed a tendency to decrease proximal migration. HA-coated cups displayed the best interface with hardly any signs of radiolucent lines, indicating a superior sealing effect of the HA coating. Cups with screws or pegs had more radiolucent lines and osteolytic lesions than the other groups. Radiolucent lines were correlated to higher proximal migration, young age, and female gender (r2=.2). The wear rate of the ethylene oxide-sterilized polyethylene liner was high (0.2 mm/y) but did not differ between the groups. Two cups with a perioperative fracture of the acetabular rim showed large initial migration but stabilized thereafter. PMID:15586331

  3. From Baby Bottle to Cup: Choose Training Cups Carefully, Use Them Temporarily

    MedlinePlus

    ... DENTAL PATIENT ... From baby bottle to cup Choose training cups carefully, use them temporarily T ooth decay ... you make the change from baby bottle to training cup, be very careful about d what kind ...

  4. World Cup Final

    NASA Technical Reports Server (NTRS)

    2006-01-01

    On July 9, hundreds of millions of fans worldwide will be glued to their television sets watching the final match of the 2006 FIFA World Cup, played in Berlin's Olympic stadium (Olympiastadion). The stadium was originally built for the 1936 Summer Olympics. The Olympic Stadium seats 76,000,; its roof rises 68 meters over the seats and is made up of transparent panels that allow sunlight to stream in during the day.

    With its 14 spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters (about 50 to 300 feet), ASTER images Earth to map and monitor the changing surface of our planet.

    ASTER is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of Economy, Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products.

    The broad spectral coverage and high spectral resolution of ASTER provides scientists in numerous disciplines with critical information for surface mapping, and monitoring of dynamic conditions and temporal change. Example applications are: monitoring glacial advances and retreats; monitoring potentially active volcanoes; identifying crop stress; determining cloud morphology and physical properties; wetlands evaluation; thermal pollution monitoring; coral reef degradation; surface temperature mapping of soils and geology; and measuring surface heat balance.

    The U.S. science team is located at NASA's Jet Propulsion Laboratory, Pasadena, Calif. The Terra mission is part of NASA's Science Mission Directorate.

    Size: 12.1 by 15.9 kilometers (7.5 by 9.5 miles) Location: 52.5 degrees North latitude, 13.3 degrees East longitude Orientation: North at top Image Data: ASTER bands 3, 2, and 1 Original Data Resolution: 15 meters (49.2 feet) Dates Acquired: October 15, 2005

  5. Bridging Suture Repair for Acetabular Chondral Carpet Delamination

    PubMed Central

    Kaya, Mitsunori; Hirose, Toshiaki; Yamashita, Toshihiko

    2015-01-01

    Acetabular chondral carpet delamination is a frequent finding at hip arthroscopy. The cartilage is macroscopically normal but deboned from the subchondral bone, without a disruption at the chondrolabral junction. Arthroscopic anatomic repair of delaminated cartilage is challenging. We propose that a combination of microfracture and use of stitches to press the delaminated cartilage against the subchondral bone using a suture limb offers an effective method to provide an environment for cartilage repair. This article describes the technique of bridging suture repair for carpet delamination in detail; the technique enables the surgeon to stabilize the delaminated acetabular cartilage. Intra-articular soft anchors and an acetabular rim knotless anchor footprint provide a stable repair for delaminated cartilage. This technique is especially helpful in cases with acetabular cartilage carpet delamination. PMID:26759774

  6. Spoon-to-Cup Fading as Treatment for Cup Drinking in a Child with Intestinal Failure

    ERIC Educational Resources Information Center

    Groff, Rebecca A.; Piazza, Cathleen C.; Zeleny, Jason R.; Dempsey, Jack R.

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup. (Contains 2…

  7. Total hip arthroplasty after rotational acetabular osteotomy.

    PubMed

    Ito, Hideya; Takatori, Yoshio; Moro, Toru; Oshima, Hirofumi; Oka, Hiroyuki; Tanaka, Sakae

    2015-03-01

    In this study, we aimed to determine whether the outcomes of total hip arthroplasty (THA) after rotational acetabular osteotomy (RAO) are equal to those of primary THA, and to elucidate the characteristics of THA after RAO. The clinical and radiographic findings of THA after RAO (44 hips), with minimum 24 months of follow-up, were compared with a matched control group of 58 hips without prior RAO. We found that the outcomes in terms of functional scores and complication rates did not differ between THA after RAO and THA without previous pelvic osteotomy, indicating that the results of THA after RAO are equivalent to those of primary THA. Although THA after RAO requires technical considerations, similar clinical outcomes to primary THA can be expected. PMID:25456635

  8. Wear of highly crosslinked polyethylene acetabular components

    PubMed Central

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Munn, Zachary; Howie, Donald W

    2015-01-01

    Background and purpose Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). Methods A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). Results 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2–10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. Interpretation This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear. PMID:25301435

  9. Versatile, high-sensitivity faraday cup array for ion implanters

    DOEpatents

    Musket, Ronald G.; Patterson, Robert G.

    2003-01-01

    An improved Faraday cup array for determining the dose of ions delivered to a substrate during ion implantation and for monitoring the uniformity of the dose delivered to the substrate. The improved Faraday cup array incorporates a variable size ion beam aperture by changing only an insertable plate that defines the aperture without changing the position of the Faraday cups which are positioned for the operation of the largest ion beam aperture. The design enables the dose sensitivity range, typically 10.sup.11 -10.sup.18 ions/cm.sup.2 to be extended to below 10.sup.6 ions/cm.sup.2. The insertable plate/aperture arrangement is structurally simple and enables scaling to aperture areas between <1 cm.sup.2 and >750 cm.sup.2, and enables ultra-high vacuum (UHV) applications by incorporation of UHV-compatible materials.

  10. Cutaneous manifestation of metallosis in a metal-on-metal total hip arthroplasty after acetabular liner dissociation.

    PubMed

    Sporer, Scott M; Chalmers, Peter N

    2012-09-01

    In this case report, we describe a cutaneous manifestation of extensive metallosis in a patient 4 months post-metal-on-metal total hip arthroplasty with a Pinnacle cup with dissociation of the liner from the shell and resultant stripe burnishing of the shell and notch wear of the femoral neck. Dissociation of a metal liner has not been previously reported with this implant. Cutaneous metallosis has only been reported once in the literature. Clinicians should heighten their suspicion for metallosis secondary to hardware failure when encountering patients with skin discoloration in the setting of a painful and poorly functioning hip arthroplasty. In patients with failure of a metal-on-metal prosthesis with a modular metal liner in the acetabular component, liner dissociation must be considered. PMID:22397858

  11. Differences in Acetabular Rim Thickness in Patients with Unilateral Symptomatic Pincer-Type Femoroacetabular Impingement

    PubMed Central

    Weber, Alexander E.; Kuhns, Benjamin; Cvetanovich, Gregory; Inoue, Nozomu; Nho, Shane Jay

    2016-01-01

    Objectives: The objective of this study was to identify the location and magnitude of difference in acetabular rim morphology between the symptomatic and asymptomatic acetabula in a cohort of patients with symptomatic unilateral pincer-type FAI. Methods: After IRB approval, computed tomography (CT) scans of 43 patients (22 males, 21 females) diagnosed with unilateral pincer-type FAI were obtained. CT images of both hips were imported in DICOM format and segmented into 3-dimensional (3D) hemi-pelvises using 3D reconstruction software (Mimics, Materialise, Leuven, Belgium). The point-cloud data of the asymptomatic hemi-pelvis was mirrored onto the symptomatic side. Protrusion of the symptomatic side was recorded as a positive value and appeared as red on the color map (Figure 1). Data was collected in 3° intervals and analyzed by quadrant using the clock face method; reflecting the 12-3, 3-6, 6-9, and 9-12 o’clock positions. Results: The symptomatic acetabular rim was on average 0.39 ± 0.36 mm thicker than the corresponding location on the asymptomatic rim. When the acetabular clock face was broken up into quadrants, reflecting the 12-3, 3-6, 6-9, and 9-12 o’clock positions, the 12-3 o’clock position demonstrated the greatest difference between symptomatic and asymptomatic sides (Table 1). The 12-3 o’clock quadrant demonstrated significantly greater difference between symptomatic and asymptomatic sides (0.53±0.22 mm) as compared to the 3-6 o’clock position (0.39±0.27 mm; p=0.006), the 6-9 o’clock position (0.34±0.05 mm; p<0.001), and the 9-12 o’clock position (0.33±0.03; p<0.001). There was no correlation between gender and magnitude of difference at any location. Conclusion: Small changes in acetabular rim morphology, on the order of 0.5 mm or less can be the difference between symptomatic pincer-type FAI and the asymptomatic state. Knowledge of the healthy, unaffected side in unilateral FAI may provide a better template for rim recession rather

  12. Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up.

    PubMed

    Epinette, Jean-Alain

    2015-02-01

    The principle of dual mobility cups, often called "tripolar", has been developed to overcome the problem of instability following primary hip arthroplasty. We prospectively compared two cohorts which differed only by the type of bearings, i.e." mobile bearing hip" (MBH) in a 143-study cohort of ADM cups versus "fixed bearing hip" (FBH) of 130 Trident PSL cups, at a follow-up at 2-6years. The survival rates at 4.13-years, with instability as endpoint was significantly (P=0.0176) in favor of mobile bearings at 100% with no dislocation reported, versus 94.8% with fixed bearings. These mobile bearings, matching both "modern" dual mobility cups and annealed highly crossed polyethylene, would appear to offer at longer follow-up a valuable solution to clinical outcomes in acetabular arthroplasty. PMID:25449593

  13. Does Cupping = Success for Olympic Athletes?

    MedlinePlus

    ... page: https://medlineplus.gov/news/fullstory_160301.html Does 'Cupping' = Success for Olympic Athletes? Telltale red circles ... I have ever seen generated about it." But does cupping actually help? There's an Eastern and a ...

  14. Preliminary Biomechanical Study of Different Acetabular Reinforcement Devices for Acetabular Reconstruction

    PubMed Central

    Tai, Ching-Lung; Lee, Po-Yi; Hsieh, Pang-Hsing

    2015-01-01

    Background Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct. However, all commercially available ARDs are designed with non-locking fixation. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction. Methods Three types of ARDs were examined to evaluate the postoperative compression and angular stability: i) standard commercial ARDs, ii) standard ARDs modified with monoaxial and iii) standard ARDs modified with polyaxial locking screw mechanisms. All ARDs were implanted into osteomized synthetic pelvis with pelvic discontinuity. Axial compression and torsion tests were then performed using a servohydraulic material testing machine that measured load (angle) versus displacement (torque). Initial stability was compared among the groups. Results Equipping ARDs with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs. In both compression and torsion experiments, the monoaxial interlocking construct demonstrated the highest construct stiffness (672.6 ± 84.1 N/mm in compression and 13.3 ± 1.0 N·m/degree in torsion), whereas the non-locked construct had the lowest construct stiffness (381.4 ± 117.2 N/mm in compression and 6.9 ± 2.1 N·m/degree in torsion) (P < 0.05). Conclusions Our study demonstrates the potential benefit of adding a locking mechanism to an ARD. Polyaxial ARDs provide the surgeon with more flexibility in placing the screws at the cost of reduced mechanical performance. This in vitro study provides a preliminary evaluation of biomechanical performance for ARDs

  15. Dummy Cup Helps Robot-Welder Programmers

    NASA Technical Reports Server (NTRS)

    Gordon, Stephen S.

    1990-01-01

    Dummy gas cup used on torch of robotic welder during programming and practice runs. Made of metal or plastic, dummy cup inexpensive and durable. Withstands bumps caused by programming errors, and is sized for special welding jobs within limited clearances. After robot satisfactorily programmed, replaced by ceramic cup of same dimensions for actual welding.

  16. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis... agents during prophylaxis (cleaning). The dental handpiece spins the rubber cup holding the...

  17. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect...

  18. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply...

  19. 21 CFR 884.5400 - Menstrual cup.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect...

  20. Coffee Cup Atomic Force Microscopy

    ERIC Educational Resources Information Center

    Ashkenaz, David E.; Hall, W. Paige; Haynes, Christy L.; Hicks, Erin M.; McFarland, Adam D.; Sherry, Leif J.; Stuart, Douglas A.; Wheeler, Korin E.; Yonzon, Chanda R.; Zhao, Jing; Godwin, Hilary A.; Van Duyne, Richard P.

    2010-01-01

    In this activity, students use a model created from a coffee cup or cardstock cutout to explore the working principle of an atomic force microscope (AFM). Students manipulate a model of an AFM, using it to examine various objects to retrieve topographic data and then graph and interpret results. The students observe that movement of the AFM…

  1. Treating the America's Cup Sailors.

    PubMed

    Miller, C

    1987-01-01

    Some physicians are taking part in efforts to win the America's Cup races, now taking place off the west coast of Australia, near Fremantle. But although 12-Meter yacht racing can be intense, sailors most often need treatment for minor injuries. PMID:27457013

  2. Medical report from the 2006 FIFA World Cup Germany

    PubMed Central

    Dvorak, Jiri; Junge, Astrid; Grimm, Katharina; Kirkendall, Donald

    2007-01-01

    Objective To continue the injury surveillance of FIFA‐sponsored football tournaments and report on other medical aspects of the 2006 FIFA World Cup. Design Prospective epidemiological injury surveillance and descriptive summary of additional medical aspects. Setting Major international football tournament. Participants National team players, doctors and referees at the 2006 FIFA World Cup Germany. Main outcome measures Injury type, location and rate. Results 145 injuries were reported for the 64 matches of the 2006 FIFA World Cup Germany—an overall injury rate of 68.7 per 1000 match hours (95% CI 57.5 to 79.9) or 2.3 injuries per match, in comparison with 2.7 injuries per match in the 2002 FIFA World Cup (p = NS). Physical examinations before participation uncovered no hidden cardiovascular problems. Once the tournament started, no referees were unable to complete their duties. There were no positive doping tests. Conclusions The injury rate for this World Cup was below that of 2002, but consistent with the overall injury rate per match since data collection began in 1998. There continues to be no evidence of systematic doping in international football. PMID:17510228

  3. Arthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note.

    PubMed

    Park, Jin Young; Chung, Woo Chull; Kim, Che Keun; Huh, Soon Ho; Kim, Se Jin; Jung, Bo Hyun

    2016-06-01

    Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report our case with technical note. PMID:27536654

  4. Arthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note

    PubMed Central

    Park, Jin young; Kim, Che Keun; Huh, Soon Ho; Kim, Se Jin; Jung, Bo Hyun

    2016-01-01

    Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report our case with technical note. PMID:27536654

  5. The submuscular sliding plate technique for acetabular posterior wall fractures extending to the acetabular roof.

    PubMed

    Kim, J J; Kim, J W; Oh, H K

    2014-12-01

    There is extension of the Kocher-Langenbeck approach using trochanteric osteotomy for posterior wall fracture extending to acetabular roof, but it exposes to complications such as nonunion, breakage, and heterotopic ossification. The current study introduces a submuscular sliding plate technique. We retrospectively analyzed 13 patients treated with this technique. It is based on conventional method for posterior wall fracture. After reduction of roof fragment with direct visualization, a pre-contoured plate was passed through a submuscular tunnel under the gluteus medius and minimus. A small split incision was performed on the muscles, and screws were inserted with a triple trocar complex safely under fluoroscopic imaging. All patients had fracture union without complications. X-rays results showed anatomical reduction in 10 cases and imperfect reduction in 3 cases. Our results were satisfactory, particularly without heterotopic ossifications despite no prophylactic regimen of NSAID was applied and no neurological complications, so we believe that this technique is a good option for posterior wall fractures extending to the acetabular roof. PMID:25453921

  6. VALIDATION OF FE MICROMOTIONS AND STRAINS AROUND A PRESS-FIT CUP: INTRODUCING A NEW MICROMOTION MEASURING TECHNIQUE

    PubMed Central

    Clarke, S G; Phillips, A T M; Bull, A M J

    2014-01-01

    Finite element analysis provides a useful tool with which to analyse the potential performance of implantations in a variety of surgical, patient and design scenarios. To enable the use of finite element analysis in the investigation of such implants, models must be experimentally validated. Validation of a pelvic model with an implanted press-fit cup in terms of micromotion and strain is presented here. A new method of micromotion has been introduced to better describe the overall movement of the cup within the pelvis. The method uses a digitizing arm to monitor the relative movement between markers on the cup and the surrounding acetabulum. Finite element analysis was used to replicate an experimental set up using a synthetic hemi-pelvis with a press-fitted all-metal cup was subject to the maximum loading observed during normal walking. The work presented here has confirmed the ability of finite element models to accurately describe the mechanical performance of the press-fitted acetabulum and surrounding bone under typical loading conditions in terms of micromotion and strain distribution, but has demonstrated limitations in its ability to predict numerical micromotion values. A promising digitizing technique for measuring acetabular micromotions has also been introduced. PMID:22350664

  7. Acetabular Labral Tears in Patients with Sports Injury

    PubMed Central

    Kang, Chan; Cha, Soo-Min

    2009-01-01

    Background We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Methods Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. Results The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. Conclusions In

  8. In vitro experiments with an injection technique for cup fixation in total hip arthroplasty.

    PubMed

    Somville, J M; Moldenaers, P F; Mulier, J C; Mewis, J J

    1987-01-01

    A new technique has been developed to position the cup rigidly into the acetabulum during total hip joint replacement. After positioning the flanged cup on the acetabulum by means of screws, a low-viscosity cement is injected through a hole in the rim of the cup. A comparison with the standard cementing technique was made on the basis of in vitro experiments. For this purpose a mold was constructed to produce castings simulating the human acetabulum. The distribution of the cement, the pressure developed in the acetabulum, and the penetration of the cement are compared for the two cementing techniques. PMID:3606358

  9. Tritanium acetabular wedge augments: short-term results

    PubMed Central

    Restrepo, Camilo; Heller, Snir

    2016-01-01

    Background Reconstruction of acetabular defects in total hip arthroplasty (THA) presents a great challenge to orthopaedic surgeons. Previous studies have reported on the use and outcomes of trabecular metal acetabular augments for the reconstruction of acetabular defects. However, no study has been conducted evaluating the short-term results of tritanium acetabular wedge augments for the reconstruction of acetabular defects in THA. Methods A retrospective study was conducted using a prospective database at a single institution including primary and revision THA patients from January 2013 to December 2014. Patients were included if they received a tritanium acetabular wedge augment system and had a minimum of 2-year follow-up (average 2.2 years ±0.3, range, 2–2.6 years). Demographic data and outcomes data [Harris Hip Score—HHS and Short Form (SF)-36] was collected. Radiographic data was also collected on THA revision cases (Paprosky classification), developmental dysplasia of the hip (DDH) cases (Crowe classification), and radiographic follow-up using DeLee and Charnley’s classification system. Results There were 4 revision THA patients, 3 DDH patients, and 1 patient with posttraumatic arthritis. At the latest radiographic follow-up, there were no lucent lines in DeLee and Charnley Zones I, II or III. During the follow-up period, there was no open revision surgery. The SF-36 physical score significantly improved from preoperative measurement (29.6±2.2) to postoperative measurement (52.2±8.7, P=0.003), and the SF-36 mental score also significantly improved from preoperative assessment (34.5±4.5) to postoperative assessment (52.2±7.5, P=0.003). Total HHS scores also significantly improved postoperatively (P=0.02), with significant improvements in both the pain score (P=0.01) and function score (P=0.02). Conclusions Tritanium acetabular wedge augments in this short follow-up case series exhibit high clinical outcome scores, no radiographic lucency, and no

  10. Lamp with a truncated reflector cup

    DOEpatents

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  11. Acetabular UHMWPE Survival and Wear Changes With Different Manufacturing Techniques

    PubMed Central

    Keating, E. Michael; Davis, Kenneth E.

    2010-01-01

    Background Polyethylene wear may be affected by the type of polyethylene resin, manufacturing technique, degree of thermal stabilization, and sterilization technique. Questions/purposes We therefore compared femoral head penetration into the PE and cup survival using the same cup system with different PE resins, manufacturing, and sterilization techniques. Methods Our study group consisted of 1912 THAs performed using the same uncemented cup and identical 28-mm cobalt-chrome heads. The polyethylene varied as follows: Group 1 (94 cups), GUR 4150 resin, ram-extruded, sterilized in air, no barrier packaging; Group 2 (74 cups), same as Group 1 but sterilized in argon; Group 3 (75 cups), Himont 1900 resin, compression-molded bar stock, sterilized in argon, no barrier packaging; Group 4 (620 cups), same as Group 3 except with barrier packing; Group 5 (711 cups), GUR 1050 resin, compression-molded bar stock, sterilized in argon gas with barrier packaging; and Group 6 (338 cups), GUR 1050 resin, compression-molded bar stock, sterilized in argon with barrier packaging, irradiated with 50 kGy, heated below melting temperature, machined, and finally placed in nonbarrier packaging with gas plasma sterilization. Minimum followup was 2 years (average, 7 years; range, 2–17 years). Results Femoral head penetration averaged 0.05 mm per year for Groups 5 and 6 and was substantially lower than for Groups 1 to 4. Cup survival was higher at seven years in Groups 3, 4, and 5, and at 10 years in group 4 when compared to groups 1, 2, and 3. Conclusions We observed lower FHP rates and higher cup survival with polyethylene machined from direct compression-molded bar stock, sterilized in argon gas, with barrier packaging. Level of Evidence Level III Therapeutic study. See Guidelines for Authors for a complete description of levels of evidence. PMID:20852973

  12. An occult acetabular fracture preceding a femoral neck fracture.

    PubMed

    Lasanianos, Nikolaos; Kanakaris, Nikolaos; Giannoudis, Peter V

    2009-08-01

    This article describes the case of a 69-year-old patient with an occult acetabular fracture complicated by an ipsilateral femoral neck fracture occurring within 2 months. The acetabular fracture remained undiagnosed at examination due to insufficient clinical and radiographic data interpretation. The patient was assured of early mobilization that led to a fall and subsequent hip fracture. We focus on the potential reasons for the nondiagnosis of the acetabular fracture. Acetabular fractures in the elderly may occur after low-energy injuries. The lack of history of violent injury may lead to an incorrect diagnosis. Plain anteroposterior (AP) pelvis radiographs alone may prove an insufficient tool, especially in the hands of inexperienced personnel. As is characteristic, a retrospective review of the AP pelvis radiograph obtained after the first fall in our case revealed the undisplaced fracture of the anterior column that was missed initially. Combined fractures of the hip and the acetabulum are rarely described in the literature and are usually addressed by total hip arthroplasty (THA) alone. Similar fracture patterns that develop in 2 stages (2 injuries), as the 1 presented herein, are even more rare. The uniqueness of this combined fracture required a unique surgical treatment. The senior surgeon (P.V.G.) addressed the acetabular fracture separately to graft the anterior column fracture and facilitate union, as it was already 8 weeks old and the second fall had generated a further gap between the fragments. Stable fixation was felt appropriate prior to the THA. Thus, a double surgical approach was used. Six weeks postoperatively, the patient was able to perform full weight-bearing mobilization without an antalgic gait pattern. At 6-month follow-up, radiographs showed the metalwork to be in place with no displacement, and the fracture had progressed to union. PMID:19708620

  13. Validation of neck axis distance as a radiographic measure for acetabular anteversion

    PubMed Central

    Nitschke, Ashley; Petersen, Brian; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer

    2016-01-01

    Excessive acetabular anteversion is an important treatment consideration in hip preservation surgery. There is currently no reliable quantitative method for determining acetabular anteversion utilizing radiographs alone. The three main purposes of this study were to: (i) define and validate the neck axis distance (NAD) as a new visual and reproducible semi-quantitative radiographic parameter used to measure acetabular anteversion; (ii) determine the degree of correlation between NAD and computed tomography (CT)-measured acetabular anteversion; (iii) establish a sensitive and specific threshold value for NAD to identify excessive acetabular anteversion. This retrospective cohort study included all patients presenting to a single institution over a 14-month period who had undergone a dedicated musculoskeletal CT pelvis along with a standardized anteroposterior (AP) pelvis radiograph. Trained observers measured the NAD on the AP pelvis radiograph and equatorial acetabular anteversion on CT for all hips. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of NAD. NAD is a valid semi-quantitative predictor of acetabular anteversion and strongly correlates with CT-measured equatorial acetabular anteversion (P  <  0.0001). A NAD measurement of greater than 14 mm predicts excessive acetabular anteversion with 76% sensitivity and 78% specificity. NAD is an accurate radiographic predictor of acetabular anteversion, which may be readily used as an effective screening tool during the evaluation of patients with hip pain. PMID:27026824

  14. Lateral acetabular labral length is inversely related to acetabular coverage as measured by lateral center edge angle of Wiberg.

    PubMed

    Petersen, Brian D; Wolf, Bryan; Lambert, Jeffrey R; Clayton, Carolyn W; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer

    2016-08-01

    Patients with developmental dysplasia of the hip often have compensatory labral hypertrophy, which presumably lends stability to an unstable joint. Conversely, patients with acetabular overcoverage may have small or ossified labra. The purpose of this study is to explore the interaction of labral length with the degree of acetabular hip coverage. A retrospective cohort of patients with hip pain presenting to a hip preservation center, who had undergone hip magnetic resonance imaging and AP pelvis radiographs were studied. General linear multivariate models were used to assess the association between three measures of labral length (lateral, anterior and anterior inferior locations along the acetabular rim) and the X-ray derived lateral center edge angle (LCEA) of Wiberg. Of the three acetabular labral locations measured, only the lateral labrum was associated with LCEA Wiberg (P = 0.0008). Lateral labral length increases as LCEA of Wiberg decreases. The anterior and anterior inferior labral locations did not show a predictable increase in labral length as LCEA Wiberg decreased. PMID:27583157

  15. Lateral acetabular labral length is inversely related to acetabular coverage as measured by lateral center edge angle of Wiberg

    PubMed Central

    Petersen, Brian D.; Wolf, Bryan; Lambert, Jeffrey R.; Clayton, Carolyn W.; Glueck, Deborah H.; Jesse, Mary Kristen; Mei-Dan, Omer

    2016-01-01

    Patients with developmental dysplasia of the hip often have compensatory labral hypertrophy, which presumably lends stability to an unstable joint. Conversely, patients with acetabular overcoverage may have small or ossified labra. The purpose of this study is to explore the interaction of labral length with the degree of acetabular hip coverage. A retrospective cohort of patients with hip pain presenting to a hip preservation center, who had undergone hip magnetic resonance imaging and AP pelvis radiographs were studied. General linear multivariate models were used to assess the association between three measures of labral length (lateral, anterior and anterior inferior locations along the acetabular rim) and the X-ray derived lateral center edge angle (LCEA) of Wiberg. Of the three acetabular labral locations measured, only the lateral labrum was associated with LCEA Wiberg (P = 0.0008). Lateral labral length increases as LCEA of Wiberg decreases. The anterior and anterior inferior labral locations did not show a predictable increase in labral length as LCEA Wiberg decreased. PMID:27583157

  16. Cementless hemispheric acetabular component in total hip replacement.

    PubMed

    Weber, D; Schaper, L A; Pomeroy, D L; Badenhausen, W E; Curry, J I; Smith, M W; Suthers, K E

    2000-01-01

    A series of 198 total hip arthroplasties was performed using a porous-coated, hemispheric press-fit cup. One hundred and twenty-seven cups were available for clinical and radiological examination at mean follow-up of 10.6 years. The mean age at the index procedure was 61.2 years. The mean Harris hip score at final follow-up was 89.8. Three cups were revised for aseptic loosening and two liners were changed for eccentric wear and pelvic osteolysis. Nine additional patients showed mild or suspected osteolysis. Two cups were rated "fibrous" stable. There was no correlation between additional screw fixation of the press-fit cup and osteolysis or revision. PMID:10990381

  17. Cheaper Custom Shielding Cups For Arc Welding

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.

    1992-01-01

    New way of making special-purpose shielding cups for gas/tungsten arc welding from hobby ceramic greatly reduces cost. Pattern machined in plastic. Plaster-of-paris mold made, and liquid ceramic poured into mold. Cost 90 percent less than cup machined from lava rock.

  18. Debonding of porous coating of a threaded acetabular component: retrieval analysis.

    PubMed

    Łapaj, Łukasz; Markuszewski, Jacek; Rybak, Tomasz; Wierusz-Kozłowska, Małgorzata

    2013-01-01

    This report presents a case of debonding of plasma sprayed porous titanium coating from a threaded acetabular component which caused aseptic loosening of the implant. Weight bearing after delamination caused abrasive damage of the acetabular shell, and particles of the coating embedded in the acetabular liner. Microscopic examination of periprosthetic tissues showed presence of metal particles and macrophage infiltration. Despite microscopic examination of the retrieved component the cause of debonding remains unclear. PMID:23127634

  19. Clinical and radiographic outcomes of acetabular impaction grafting without cage reinforcement for revision hip replacement: a minimum ten-year follow-up study.

    PubMed

    Gilbody, J; Taylor, C; Bartlett, G E; Whitehouse, S L; Hubble, M J W; Timperley, A J; Howell, J R; Wilson, M J

    2014-02-01

    Impaction bone grafting for the reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. Between 1995 and 2001 we used this technique in acetabular reconstruction, in combination with a cemented component, in 304 hips in 292 patients revised for aseptic loosening. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of ten years after the index operation. Mean follow-up was 12.4 years (sd 1.5) (10.0 to 16.0). Kaplan-Meier survival with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared radiologically loose. PMID:24493183

  20. Arthroscopic repair of acetabular chondral delamination with fibrin adhesive.

    PubMed

    Tzaveas, Alexandros P; Villar, Richard N

    2010-01-01

    Acetabular chondral delamination is a frequent finding at hip arthroscopy. The cartilage is macroscopically normal but disrupted from the subchondral bone. Excision of chondral flaps is the usual procedure for this type of lesion. However, we report 19 consecutive patients in whom the delaminated chondral flap was re-attached to the underlying subchondral bone with fibrin adhesive. We used the modified Harris hip score for assessment of pain and function. Improvement in pain and function was found to be statistically significant six months and one year after surgery. No local or general complications were noted. Three patients underwent further surgery for unrelated reasons. In each, the area of fibrin repair appeared intact and secure. Our results suggest that fibrin is a safe agent to use for acetabular chondral delamination. PMID:20235074

  1. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    SciTech Connect

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion.

  2. Stress fracture in acetabular roof due to motocross: case report.

    PubMed

    de Paiva Luciano, Alexandre; Filho, Nelson Franco

    2016-01-01

    One of the first steps to be taken in order to reduce sports injuries such as stress fractures is to have in-depth knowledge of the nature and extent of these pathological conditions. We present a case report of a stress fracture of the acetabular roof caused through motocross. This type of case is considered rare in the literature. The description of the clinical case is as follows. The patient was a 27-year-old male who started to have medical follow-up because of uncharacteristic pain in his left hip, which was concentrated mainly in the inguinal region of the left hip during motocross practice. After clinical investigation and complementary tests, he was diagnosed with a stress fracture of the acetabular roof. PMID:27274494

  3. Acetabular Paralabral Cyst: An Unusual Cause of Femoral Vein Compression

    PubMed Central

    Kullar, Raj S.; Kapron, Ashley L.; Ihnat, Daniel; Aoki, Stephen K.; Maak, Travis G.

    2015-01-01

    Acetabular labral tears are a known cause of hip pain in the young, active patient. Labral tears can be due to trauma, femoroacetabular impingement, capsular laxity, dysplasia, and degenerative pathology. Paralabral cysts are relatively common in association with labral tears of the hip, with cysts seen on magnetic resonance imaging studies in as many as 50% to 70% of patients with labral tears. In some cases the cysts can become sizeable and cause neurovascular compression. Nonoperative interventions for the management of paralabral cysts in the shoulder and knee have shown high recurrence rates. In the shoulder and knee, arthroscopic debridement of paralabral cysts has shown good results with lower recurrence rates and resolution of neurovascular function. In the hip there is limited literature regarding surgical management of paralabral cysts. We present a surgical technique for arthroscopic decompression of acetabular paralabral cysts combined with labral repair. PMID:25973371

  4. The Use of Iliac Stem Prosthesis for Acetabular Defects following Resections for Periacetabular Tumors

    PubMed Central

    De Paolis, Massimiliano; Romagnoli, Carlo; Alì, Nikolin; Giannini, Sandro; Donati, Davide Maria

    2013-01-01

    Introduction. The management of pelvic tumors is a challenge for orthopaedic oncologists due to the complex anatomy of the pelvis and the need to have extensive exposure. Various reconstructive techniques have been proposed with poor functional results and a high percentage of complications. Our purpose is to determine the functional results and the rate of complications of iliac stem prosthesis for acetabular defects following resections for periacetabular tumors. Materials and Methods. Between 1999 and 2012, 45 patients underwent pelvic resections for periacetabular bone tumors followed by reconstruction with stem cup prosthesis. The most common diagnosis was CS (chondrosarcoma, 29 cases), followed by OS (osteosarcoma, 9 cases) and metastasis (3 cases). In 33 cases, this implant was associated with massive bone allografts. Minimum follow-up required to evaluate functional outcome was 2 years. We classified pelvic resections according to Enneking and Dunham's classification and we used MSTS (musculoskeletal tumor system) score to evaluate functional outcomes. Results and Discussion. Sixteen patients died of their disease, three were lost to follow-up, four are alive with disease, and twenty-two are alive with no evidence of disease. Fifteen patients had local recurrence. Sixteen patients had bone or lung metastasis. We have had 6 infections, 2 aseptic loosening, and 2 cases of hip dislocation. Iliac sovracetabular osteotomy was fused in all cases at 10 months from surgery. Functional results were good or excellent in 25 of 31 patients with long-term follow-up (77%), with a percentage similar to that reported in the literature. Conclusion. The use of iliac stem prosthesis is a simple reconstructive technique that reduces operative times and risk of infection. It allows having good results and low rate of complications, but it should be performed in selected cases and centres of reference. PMID:24250275

  5. The Incidence of Acetabular Osteolysis in Young Patients With Conventional versus Highly Crosslinked Polyethylene

    PubMed Central

    Mall, Nathan A.; Nunley, Ryan M.; Zhu, Jin Jun; Maloney, William J.; Barrack, Robert L.

    2010-01-01

    Background Osteolysis is a major mode of hip implant failure. Previous literature has focused on the amount of polyethylene wear comparing highly crosslinked polyethylene (HXPLE) with conventional liners but has not clarified the relative incidence of osteolysis with these two liners. Questions/purposes We determined (1) the incidence of osteolysis in HXLPE versus conventional polyethylene (CPE), (2) the ability to detect and evaluate the size of lytic lesions using radiographs compared with CT scans, (3) head penetration in hips without and with lysis, and (4) determined whether acetabular position, head size, and UCLA activity score contributed to lysis. Methods We compared head penetration and osteolysis on plain radiographs and presence and volume of osteolysis on CT scans in 48 patients with HXLPE (mean, 46.5 years) and 50 patients with CPE (mean, 43.2 years). The minimum followup was 5 years (average, 7.2 years; range, 5.1–10.9 years), Results Osteolysis was apparent on CT in a larger number of patients with CPE liners than HXLPE liners: 12 of 50 (24%) versus one of 48 (2%), respectively. We found no correlation between head penetration and volume of osteolytic lesions. Head penetration was greater in patients with osteolysis. Smaller head sizes were associated with greater wear and those with osteolysis had smaller head sizes; however, there was no difference in acetabular component position or UCLA activity in those with lysis compared with those without. Conclusions HXLPE diminished the incidence of osteolysis, but the lack of correlation between penetration and volume of osteolysis suggests other factors other than wear contribute to the development of osteolysis. Level of Evidence Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence. PMID:20824407

  6. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  7. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  8. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  9. Positioning.

    ERIC Educational Resources Information Center

    Conone, Ruth M.

    The key to positioning is the creation of a clear benefit image in the consumer's mind. One positioning strategy is creating in the prospect's mind a position that takes into consideration the company's or agency's strengths and weaknesses as well as those of its competitors. Another strategy is to gain entry into a position ladder owned by…

  10. Intermediate clinical follow-up of a dual-radius acetabular component.

    PubMed

    Van Flandern, G J; Bierbaum, B E; Newberg, A H; Gomes, S L; Mattingly, D A; Karpos, P A

    1998-10-01

    In this study, 92 primary total hip arthroplasties were performed in 83 patients using a porous-coated, dual-radius, cementless, acetabular component. All hips underwent line-to-line dome reaming with press-fit implantation that was judged to have complete bone contact. This acetabular shell provides a 1-mm oversized peripheral rim, which adds excellent initial stability while allowing complete bone contact in all hips. No fractures occurred. In 83% of hips, adjunctive screw fixation was not necessary. At a minimum of 4 years, follow-up, there were no revisions, no acetabular migration, one case of acetabular erosion consistent with osteolysis, and the average Harris Hip Score was 95. The design features of this new acetabular component have provided excellent fixation with complete initial bone contact, resulting in satisfactory intermediate clinical and radiographic results. The design provides excellent peripheral stability and complete bone contact. PMID:9802669

  11. Arthroscopic Technique for Chondrolabral Capsular Preservation During Labral Repair and Acetabular Osteoplasty

    PubMed Central

    Nwachukwu, Benedict U.; McCormick, Frank; Martin, Scott D.

    2013-01-01

    Traditional techniques for acetabular osteoplasty in femoral acetabular impingement have required surgical detachment of the labrum at the chondrolabral junction. Such approaches compromise labral blood flow and contribute to a limited ability for healing at the chondrolabral junction. In this technical note and accompanying video, we present a technique for preservation of the chondrolabral junction during labral repair and acetabular osteoplasty. We elevate the chondrolabral complex subperiosteally off the acetabular rim, and the acetabular shelf is then contoured under fluoroscopic guidance. The labrum is then repaired and reconstituted to a new anatomic footprint. We find this technique to be advantageous because it preserves the blood flow to the labrum, thereby maximizing healing potential. Outcome studies are warranted to further elucidate the functional and outcome benefits of this surgical technique. PMID:24265986

  12. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    PubMed

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction. PMID:24350878

  13. Enhanced modified faraday cup for determination of power density distribution of electron beams

    DOEpatents

    Elmer, John W.; Teruya, Alan T.

    2001-01-01

    An improved tomographic technique for determining the power distribution of an electron or ion beam using electron beam profile data acquired by an enhanced modified Faraday cup to create an image of the current density in high and low power ion or electron beams. A refractory metal disk with a number of radially extending slits, one slit being about twice the width of the other slits, is placed above a Faraday cup. The electron or ion beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. The enlarged slit enables orientation of the beam profile with respect to the coordinates of the welding chamber. A second disk having slits therein is positioned below the first slit disk and inside of the Faraday cup and provides a shield to eliminate the majority of secondary electrons and ions from leaving the Faraday cup. Also, a ring is located below the second slit disk to help minimize the amount of secondary electrons and ions from being produced. In addition, a beam trap is located in the Faraday cup to provide even more containment of the electron or ion beam when full beam current is being examined through the center hole of the modified Faraday cup.

  14. Is labral hypotrophy correlated with increased acetabular depth?

    PubMed

    Toft, Felix; Anliker, Elmar; Beck, Martin

    2015-07-01

    Labral hypertrophy is a distinct feature in hip dysplasia. Occasionally, very small, hypotrophic labra are observed. However, there is no literature concerning this pathology. We investigated if the size of the labrum correlated with any radiologic parameters reflecting the amount of acetabular coverage. It was hypothezised that there is a negative correlation between labrum size and acetabular coverage. Labra were categorized into three groups depending on the relation between length of the articular sided surface and height of bony attachment. Labra with a height:length ratio of 2 were classified as hypotrophic, with a height:length ratio of 1 as normal and with a ratio of 0.5 as hypertrophic. Labral cross-sectional areas (CSA) were measured on radial magnetic resonance imaging-arthrography slices using the measuring tool of the PACS system of 20 hips with hypotrophic labra (group 1), 20 hips with normal labral appearance (group 2) and 10 hips with hypertrophic labra (group 3). These values were then analyzed against following parameters: neck-shaft-angle (NSA), lateral center-edge angle (LCE), acetabular index (AI), femoral extrusion index (FEI) and acetabular retroversion index (ARI). Analyses of variance were used to determine differences in mean values between the three groups. Mean labral CSA differed significantly between all groups (group 1: 12.1 ± 2.9 mm(2); group 2: 25.2 ± 6.2 mm(2); group 3: 41.1 ± 12.3 mm(2); P < 0.001). NSA, LCE, AI and FEI all showed a significant difference between group 3 and 1 or 2. The ARI showed no difference between groups. Stepwise linear regression analyses showed a significant correlation between LCE angle and labral CSA with a corrected R (2)-value of 0.301. Labral CSA correlates with the LCE. No statistically significant difference between groups 1 and 2 concerning the LCE, AI or FEI could be identified. Nevertheless, group 1 had the highest mean coverage of all groups, hips with hypertrophic

  15. Is labral hypotrophy correlated with increased acetabular depth?

    PubMed Central

    Toft, Felix; Anliker, Elmar; Beck, Martin

    2015-01-01

    Labral hypertrophy is a distinct feature in hip dysplasia. Occasionally, very small, hypotrophic labra are observed. However, there is no literature concerning this pathology. We investigated if the size of the labrum correlated with any radiologic parameters reflecting the amount of acetabular coverage. It was hypothezised that there is a negative correlation between labrum size and acetabular coverage. Labra were categorized into three groups depending on the relation between length of the articular sided surface and height of bony attachment. Labra with a height:length ratio of 2 were classified as hypotrophic, with a height:length ratio of 1 as normal and with a ratio of 0.5 as hypertrophic. Labral cross-sectional areas (CSA) were measured on radial magnetic resonance imaging-arthrography slices using the measuring tool of the PACS system of 20 hips with hypotrophic labra (group 1), 20 hips with normal labral appearance (group 2) and 10 hips with hypertrophic labra (group 3). These values were then analyzed against following parameters: neck-shaft-angle (NSA), lateral center-edge angle (LCE), acetabular index (AI), femoral extrusion index (FEI) and acetabular retroversion index (ARI). Analyses of variance were used to determine differences in mean values between the three groups. Mean labral CSA differed significantly between all groups (group 1: 12.1 ± 2.9 mm2; group 2: 25.2 ± 6.2 mm2; group 3: 41.1 ± 12.3 mm2; P < 0.001). NSA, LCE, AI and FEI all showed a significant difference between group 3 and 1 or 2. The ARI showed no difference between groups. Stepwise linear regression analyses showed a significant correlation between LCE angle and labral CSA with a corrected R2-value of 0.301. Labral CSA correlates with the LCE. No statistically significant difference between groups 1 and 2 concerning the LCE, AI or FEI could be identified. Nevertheless, group 1 had the highest mean coverage of all groups, hips with hypertrophic labra

  16. [Total arthroplasty of the hip with a screwed titanium ring cup. Follow-up of 446 prostheses over four years].

    PubMed

    Witvoët, J; Darman, Z; Christel, P; Fumery, F

    1993-01-01

    The current decrease of total hip arthroplasty using a cemented polyethylene cup point out that bone-cement interface and polyethylene wear are two weak points responsible for long term loosening. Alumina-alumina combination can avoid one of the weak points. But fixing an alumina cup with cement doesn't avoid the second one. So from 1983 we have been using a cup composed by a titanium alloy threaded ring with an alumina insert. From the 508 prosthesis we fixed in between 1983 and 1989, 446 have been followed up over one year with an average follow-up 4 +/- 1.6 years. The patients mean age was 61.7 +/- 12 years. 368 were primary THA performed mostly for osteoarthrosis, 78 were performed in revision cases of cemented cup. All the femoral stems were cemented, we noted only two loosenings. The clinical results were satisfactory in primary arthroplasties (90.7 per cent satisfactory results in the R. Merle d'Aubigné and M. Postel scoring system), whereas in revision cases of cemented cups the percentage of non satisfactory results (32.8 per cent) was very high. Nevertheless migration rate of the threaded rings was 13 per cent (n = 48/368) in primary operation. 8.11 per cent when no structural graft was needed, 22.8 per cent when grafted. Although only 17/48 have been revised up to now, the future of the last 31 remain uncertain. In our opinion, the threaded cup should not be used in revision cases of cemented cups. The long term fixation of a threaded cup remains a problem for the dysplasic acetabula. For the non dysplasic non operated acetabula the migration factors are statistically: female sex, osteoporosis whatever the aetiology, a wrong primary positioning (cup too vertical, protrusio). For all these reasons, from 1989 we have been using a press-fit titanium cup, with promising results. PMID:8085036

  17. Acetabular fractures: what radiologists should know and how 3D CT can aid classification.

    PubMed

    Scheinfeld, Meir H; Dym, Akiva A; Spektor, Michael; Avery, Laura L; Dym, R Joshua; Amanatullah, Derek F

    2015-01-01

    Correct recognition, description, and classification of acetabular fractures is essential for efficient patient triage and treatment. Acetabular fractures may result from high-energy trauma or low-energy trauma in the elderly. The most widely used acetabular fracture classification system among radiologists and orthopedic surgeons is the system of Judet and Letournel, which includes five elementary (or elemental) and five associated fractures. The elementary fractures are anterior wall, posterior wall, anterior column, posterior column, and transverse. The associated fractures are all combinations or partial combinations of the elementary fractures and include transverse with posterior wall, T-shaped, associated both column, anterior column or wall with posterior hemitransverse, and posterior column with posterior wall. The most unique fracture is the associated both column fracture, which completely dissociates the acetabular articular surface from the sciatic buttress. Accurate categorization of acetabular fractures is challenging because of the complex three-dimensional (3D) anatomy of the pelvis, the rarity of certain acetabular fracture variants, and confusing nomenclature. Comparing a 3D image of the fractured acetabulum with a standard diagram containing the 10 Judet and Letournel categories of acetabular fracture and using a flowchart algorithm are effective ways of arriving at the correct fracture classification. Online supplemental material is available for this article. PMID:25763739

  18. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture.

    PubMed

    Jo, Woo Lam; Lee, Woo Suk; Chae, Dong Sik; Yang, Ick Hwan; Lee, Kyoung Min; Koo, Kyung Hoi

    2016-10-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum. PMID:27550496

  19. Role of the Acetabular Labrum in Load Support Across the Hip Joint

    PubMed Central

    Henak, Corinne R.; Ellis, Benjamin J.; Harris, Michael D.; Anderson, Andrew E.; Peters, Christopher L.; Weiss, Jeffrey A.

    2011-01-01

    The relatively high incidence of labral tears among patients presenting with hip pain suggests that the acetabular labrum is often subjected to injurious loading in vivo. However, it is unclear whether the labrum participates in load transfer across the joint during activities of daily living. This study examined the role of the acetabular labrum in load transfer for hips with normal acetabular geometry and acetabular dysplasia using subject-specific finite element analysis. Models were generated from volumetric CT data and analyzed with and without the labrum during activities of daily living. The labrum in the dysplastic model supported 4-11% of the total load transferred across the joint, while the labrum in the normal model supported only 1-2% of the total load. Despite the increased load transferred to the acetabular cartilage in simulations without the labrum, there were minimal differences in cartilage contact stresses. This was because the load supported by the cartilage correlated to the cartilage contact area. A higher percentage of load was transferred to the labrum in the dysplastic model because the femoral head achieved equilibrium near the lateral edge of the acetabulum. The results of this study suggest that the labrum plays a larger role in load transfer and joint stability in hips with acetabular dysplasia than in hips with normal acetabular geometry. PMID:21757198

  20. Transosseous Acetabular Labral Repair as an Alternative to Anchors

    PubMed Central

    Pérez-Carro, Luis; Cabello, Andres Gonzalez; Rakha, Mohamed Ibrahim; Patnaik, Sarthak; Centeno, Elias; Miranda, Victor; Fernández, Ana Alfonso

    2015-01-01

    Labral tears are the most common pathology in patients undergoing hip arthroscopy and the most common cause of mechanical hip symptoms. Labral repair techniques have been described in the literature using suture anchors placed as close as possible to the acetabular rim without penetrating the articular surface. Optimal surgical technique for labral repair is very important, and an inappropriate entry point and guide angulation may lead to intra-articular penetration of the anchor, chondral damage, anchor loosening, or inadequate fixation. A shallow dysplastic hip, the drilling trajectory, the narrow width of the acetabular rim, or some specific anatomic variations may generate difficulty during anchor placement. Suture anchors themselves have been associated with several significant complications, including rim fracture, osteolysis, enlargement of drill holes, and infection. The treatment of labral lesions with transosseous suture is an alternative to anchor use, eliminating the need for anchors and avoiding anchor-associated complications. This technique offers versatility to surgeons and is more cost-effective for patients and health services. We aim to describe the indications and technique for transosseous labral repair without anchors. PMID:26697295

  1. Subchondral Insufficiency Fracture of the Femoral Head Caused by Excessive Lateralization of the Acetabular Rim

    PubMed Central

    Kimura, Tetsuya; Goto, Tomohiro; Hamada, Daisuke; Tsutsui, Takahiko; Wada, Keizo; Fukuta, Shoji; Nagamachi, Akihiro; Sairyo, Koichi

    2016-01-01

    We present a case of a 53-year-old woman with subchondral insufficiency fracture (SIF) of the femoral head without history of severe osteoporosis or overexertion. Plain radiographs showed acetabular overcoverage with excessive lateralization of the acetabular rim. A diagnosis of SIF was made by typical MRI findings of SIF. The lesion occurred at the antipodes of the extended rim. Increased mechanical stress over the femoral head due to impingement against the excess bone was suspected as a cause of SIF. The distinct femoral head deformity is consistent with this hypothesis. This is the first report of SIF associated with acetabular overcoverage. PMID:27293935

  2. An Updated Review of the Efficacy of Cupping Therapy

    PubMed Central

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Background Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Method Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. Results 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Conclusions Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted. PMID:22389674

  3. Back-side wear in HexLoc cups clinico-radiological, immunohistopathological, finite element, and retrieval analysis studies.

    PubMed

    Kawaji, Hiroyuki; Koistinen, Arto; Korhonen, Rami; Lappalainen, Reijo; Lohman, Martina; Soininen, Antti; Gomez Barrena, Enrique; Konttinen, Yrjo T; Ylinen, Pekka; Tallroth, Kaj

    2014-01-01

    The HexLoc locking system was designed to prevent back-side wear of the polyethylene liner in the modular cementless metal-backed acetabular cup, but failed. Back-side wear was analyzed using clinico-radiological data, immunohistopathology, finite element modeling (FEM, and retrieval analysis. Screw holes allowed entry of titanium oxide and exit of polyethylene particles. Birefringent polyethylene wear particles were found behind the metal cup in macrophages containing pro-inflammatory tumor necrosis factor-α and interleukin-1β, whereas fibroblast-like cells stained for osteoclastogenic receptor activator of nuclear factor kappa B ligand (RANKL). Computerized tomography revealed granulomas (83% versus 17 %) and cortical destruction (50% versus 5%) better than radiographs. In FEM, a change of the abduction angle from 45 to 60 deg, and liner thickness from 4.8 mm to 2.5 mm, increased the back-side wear by 90% and 120%, respectively. Screw holes were stress concentration areas; their removal decreased wear by 40%. Modeling results were validated in retrieved implants, which demonstrated extensive back-side wear damage of liners with a high abduction angle. Combined clinico-radiological, immunohistopathological, FEM, and retrieval analysis disclosed that back-side wear in the HexLoc design is sensitive to the abduction angle, liner thickness, and presence of screw holes. PMID:25747033

  4. Migration and wear of hydroxyapatite-coated press-fit cups in revision hip arthroplasty: a radiostereometric study.

    PubMed

    Nivbrant, B; Kärrholm, J

    1997-12-01

    Screw-fixated and hydroxyapatite-coated press-fit cups were studied using radiostereometry in 29 revision and 14 primary arthroplasties. The acetabular defects in the revision cases varied from none to type 3 (wall defects) according to Gustilo-Pasternak. Morsellized allograft was used in 25 revisions. Nine of these cups rested on less than 50% living bone. After 2 years, the mean migration in the revised group reached 0.36, 0.21, and 0.49 mm in the horizontal, longitudinal, and anteroposterior (AP) directions. The mean rotations varied between 0.5 degrees and 0.7 degrees depending on direction. The primary implants displayed smaller mediolateral migration and AP tilt. The mean proximal wear rate for the whole group was 0.11 mm/y. A central gap on the postoperative AP view implied less migration. The size of the preoperative bone defects or amount of bone-graft used had no influence on the migration. Despite extensive use of morsellized allograft, this implant displayed the smallest migration so far reported in revision hip arthroplasty. PMID:9458256

  5. The results of a press-fit-only technique for acetabular fixation in hip dysplasia.

    PubMed

    Takao, Masaki; Nakamura, Nobuo; Ohzono, Kenji; Sakai, Takashi; Nishii, Takashi; Sugano, Nobuhiko

    2011-06-01

    The purpose of the present study was to evaluate the 6- to 11-year follow-up results of hemispherical porous-coated cups implanted into dysplastic hips using press-fit technique without screws focusing on the amount of host bone coverage. There were 87 patients who underwent 98 primary total hip arthroplasties. Bony coverage was measured as the angle between the vertical line and the line drawn from the cup center to the lateral edge of the acetabulum, which was named the cup center-edge angle (cup-CE angle). All 98 cups were judged to be bone ingrown. The minimum cup-CE angle was 8.4° (mean, 26.3°). Bone-cup contact of more than 8.4° of the cup-CE angle was large enough for press-fit cups to resist superior directed loads during this follow-up period. PMID:20647158

  6. Gas-Diverting Cup For Welding At An Angle

    NASA Technical Reports Server (NTRS)

    Dyer, G. E.

    1988-01-01

    Attachment makes automatic arc welders more versatile. Stainless-steel diverting cup slips over standard torch cup. Bent electrode inserted in torch. Assembly reaches weld joints inaccessible to straight welding torch.

  7. Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP)

    PubMed Central

    Sköldenberg, Olof; Rysinska, Agata; Chammout, Ghazi; Salemyr, Mats; Muren, Olle; Bodén, Henrik; Eisler, Thomas

    2016-01-01

    Introduction In vitro, Vitamin-E-diffused, highly cross-linked polyethylene (PE) has been shown to have superior wear resistance and improved mechanical properties when compared to those of standard highly cross-linked PE liners used in total hip arthroplasty (THA). The aim of the study is to evaluate the safety of a new cemented acetabular cup with Vitamin-E-doped PE regarding migration, head penetration and clinical results. Methods and analysis In this single-centre, double-blinded, randomised controlled trial, we will include 50 patients with primary hip osteoarthritis scheduled for THA and randomise them in a 1:1 ratio to a cemented cup with either argon gas-sterilised PE (control group) or Vitamin-E-diffused PE (vitamin-e group). All patients and the assessor of the primary outcome will be blinded and the same uncemented stem will be used for all participants. The primary end point will be proximal migration of the cup at 2 years after surgery measured with radiostereometry. Secondary end points include proximal migration at other follow-ups, total migration, femoral head penetration, clinical outcome scores and hip-related complications. Patients will be followed up at 3 months and at 1, 2, 5 and 10 years postoperatively. Results Results will be analysed using 95% CIs for the effect size. A regression model will also be used to adjust for stratification factors. Ethics and dissemination The ethical committee at Karolinska Institutet has approved the study. The first results from the study will be disseminated to the medical community via presentations and publications in relevant medical journals when the last patient included has been followed up for 2 years. Trial registration number NCT02254980. PMID:27388352

  8. Fast Faraday Cup With High Bandwidth

    DOEpatents

    Deibele, Craig E [Knoxville, TN

    2006-03-14

    A circuit card stripline Fast Faraday cup quantitatively measures the picosecond time structure of a charged particle beam. The stripline configuration maintains signal integrity, and stitching of the stripline increases the bandwidth. A calibration procedure ensures the measurement of the absolute charge and time structure of the charged particle beam.

  9. Nuclear Physics in a Coffee Cup

    ERIC Educational Resources Information Center

    Higbie, J.

    1974-01-01

    Discusses physical phenomena which can be demonstrated by using a coffee cup, involving the short-range field, alpha-particle scattering, standing waves, and Bohr's closed electron orbits. Indicates that observation of the physics of the classroom in everyday objects can attract student interest in physics learning. (CC)

  10. Recycling disposable cups into paper plastic composites.

    PubMed

    Mitchell, Jonathan; Vandeperre, Luc; Dvorak, Rob; Kosior, Ed; Tarverdi, Karnik; Cheeseman, Christopher

    2014-11-01

    The majority of disposable cups are made from paper plastic laminates (PPL) which consist of high quality cellulose fibre with a thin internal polyethylene coating. There are limited recycling options for PPLs and this has contributed to disposable cups becoming a high profile, problematic waste. In this work disposable cups have been shredded to form PPL flakes and these have been used to reinforce polypropylene to form novel paper plastic composites (PPCs). The PPL flakes and polypropylene were mixed, extruded, pelletised and injection moulded at low temperatures to prevent degradation of the cellulose fibres. The level of PPL flake addition and the use of a maleated polyolefin coupling agent to enhance interfacial adhesion have been investigated. Samples have been characterised using tensile testing, dynamic mechanical analysis (DMA) and thermogravimetric analysis. Use of a coupling agent allows composites containing 40 wt.% of PPL flakes to increase tensile strength of PP by 50% to 30 MPa. The Young modulus also increases from 1 to 2.5 GPa and the work to fracture increases by a factor of 5. The work demonstrates that PPL disposable cups have potential to be beneficially reused as reinforcement in novel polypropylene composites. PMID:24994469

  11. Biorobotic adhesion in water using suction cups.

    PubMed

    Bandyopadhyay, Promode R; Hrubes, J Dana; Leinhos, Henry A

    2008-03-01

    Echeneid fish, limpets and octopi use suction cups for underwater adhesion. When echeneid fish use suckers to 'hitch a ride' on sharks (which have riblet-patterned skins), the apparent absence of any pump or plumbing may be an advantage over biorobotic suction cups. An intriguing question is: How do they achieve seemingly persistent leak-free contact at low energy cost over rough surfaces? The design features of their suckers are explored in a biorobotic context of adhesion in water over rough surfaces. We have carried out experiments to compare the release force and tenacity of man-made suction cups with those reported for limpets and echeneid fish. Applied tensile and shear release forces were monotonically increased until release. The effects of cup size and type, host surface roughness, curvature and liquid surface tension have been examined. The flow of water in the sharkskin-like host surface roughness has been characterized. The average tenacity is 5.28 N cm(-2) (sigma = 0.53 N cm(-2), N = 37) in the sub-ambient pressure range of 14.6-49.0 kPa, in man-made cups for monotonically increasing applied release force. The tenacity is lower for harmonically oscillating release forces. The dynamic structural interactions between the suction cup and the oscillating applied forcing are discussed. Inspired by the matching of sharkskin riblet topology in echeneid fish suckers, it was found that biorobotic sealed contact over rough surfaces is also feasible when the suction cup makes a negative copy of the rough host surface. However, for protracted, persistent contact, the negative topology would have to be maintained by active means. Energy has to be spent to maintain the negative host roughness topology to minute detail, and protracted hitch-riding on sharks for feeding may not be free for echeneid fish. Further work is needed on the mechanism and efficiency of the densely populated tiny actuators in the fish suckers that maintain leak-proof contact with minimal

  12. Rapid resolution of femoral head osteonecrosis after rotational acetabular osteotomy.

    PubMed

    Nozawa, Masahiko; Matsuda, Keiji; Maezawa, Katsuhiko; Kim, Sungon; Maeda, Kouichi; Ikegami, Takashi; Kubota, Reiko; Hayashi, Kentaro; Nagayama, Masataka; Kaneko, Haruka

    2008-12-01

    The natural history of osteonecrosis of the femoral head is generally thought to be one of progressive deterioration if no intervention is undertaken. However, it is unknown whether surgical intervention is beneficial for patients with a small region of osteonecrosis. We observed rapid improvement of MRI findings after rotational acetabular osteotomy (RAO) was performed in a young patient with osteonecrosis of the femoral head. The band-like low signal area on T2-weighted images almost resolved by six months after surgery. He returned to work as an electrician by six months after surgery. Early surgical intervention such as RAO that alters the mechanical force acting on the necrotic region of the femoral head may accelerate the recovery of osteonecrosis and the improvement of symptoms. PMID:19384490

  13. Retained Sponge: A Rare Complication in Acetabular Osteosinthesis

    PubMed Central

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Moran-Blanco, Luz María; Vaquero-Martín, Javier

    2015-01-01

    Retained sponges after a surgical treatment of polytrauma may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a 35-year-old man transferred from another hospital, that sustained a open acetabular fracture. The fracture was reduced through a limited ilio-inguinal approach. After 4 days, he presented massive wound dehiscence of the surgical approach. An abdominal CT scan showed, lying adjacent to the outer aspect of the left iliac crest, a mass of 10 cm, identified as probable foreign body. The possibility of this rare complication should be in the differential diagnosis of any postoperative patient who presents with pain, infection, or palpable mass. PMID:26312116

  14. Failure analysis of retrieved PE-UHMW acetabular liners.

    PubMed

    Laska, Anna; Archodoulaki, Vasiliki-Maria; Duscher, Bernadette

    2016-08-01

    Ultra-high molecular weight polyethylene (PE-UHMW) acetabular liners have a limited lifespan in a patient's body. There are many factors affecting the performance of the implant and furthermore the properties of the polymeric material are changing after implantation. In this work material changes according to structure and morphology and their implication on mechanical properties are in focus. The physical and mechanical properties of ten crosslinked (xL) PE-UHMW and nine conventional (conv) gamma-sterilized PE-UHMW hip components, used as sliding surface in total hip joint replacement, with different in-vivo times are compared. The evaluation of the retrieved acetabular liners is performed in view of crosslinking and conventional gamma-sterilization but also in terms of the influence of gender concerning alteration in properties. The oxidative degradation in the PE-UHMW is investigated by means of Fourier Transformed Infrared Spectroscopy (FTIR). The characterization of the morphology is carried out via differential scanning calorimetry (DSC). A depth profile of the micro-hardness and elastic modulus is taken over the cross-section of the components in order to find the influence of chemical constitution and morphology on the micro-mechanical properties. It could be shown that crosslinking and oxidative degradation influence the degree of crystallinity of the polymer. Oxidation occurs for both types of the material due to in-vivo time. Higher degree of crystallinity can be correlated to higher hardness and indentation modulus. No unequivocal superiority of crosslinked over conventional liners can be observed. The influence of sex concerning alteration of the evaluated properties matters but need to be further investigated. PMID:26849029

  15. Hip Arthroscopy in the Presence of Acetabular Dysplasia

    PubMed Central

    Jayasekera, Narlaka; Aprato, Alessandro; Villar, Richard N

    2015-01-01

    Purpose : Hip arthroscopy is a well established therapeutic intervention for an increasing number of painful hip conditions. Developmental dysplasia of the hip (DDH) is commonly associated with intra-articular hip pathology. However, some surgeons perceive patients with hip dysplasia as poor candidates for hip arthroscopy. Our aim was to describe early outcomes of arthroscopic treatment for patients with DDH, who also had femoroacetabular impingement (FAI) treated when necessary, and to compare these outcomes against a control group of patients without DDH. Methods : Prospective case-control study of 68 consecutive hip arthroscopy patients assessed with a modified Harris Hip Score (mHHS) preoperatively and at six weeks, six months, and one year after surgery. Presence of DDH was determined using a standard anteroposterior (AP) pelvic radiograph to measure the centre-edge angle (CEA) of Wiberg, with a CEA < 20º used as threshold for diagnosis of DDH. Results : 12 patients (eight female and four male) with acetabular dysplasia and mean CEA of 15.4º (9º to 19º). The control, nondysplastic group comprised 54 patients (23 females and 31 males) with a mean CEA of 33.1º (22º to 45º). All patients in the dysplastic group had a labral tear and 11 (91.7%) had associated femoral cam impingement lesion addressed at arthroscopy. Our study demonstrates a significant (p=0.02) improvement in outcome in the dysplastic group at one year using the mHHS. Conclusion : Hip arthroscopy in the presence of DDH is effective in relieving pain for at least one year after surgery although does not address underlying acetabular abnormality. PMID:26069512

  16. The capsular ligaments provide more hip rotational restraint than the acetabular labrum and the ligamentum teres

    PubMed Central

    van Arkel, R. J.; Amis, A. A.; Cobb, J. P.; Jeffers, J. R. T.

    2015-01-01

    In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty. Cite this article: Bone Joint J 2015; 97-B:484–91. PMID:25820886

  17. The Standardization of Bra Cup Measurements: Redefining Bra Sizing Language.

    PubMed

    Bengtson, Bradley P; Glicksman, Caroline A

    2015-10-01

    There are many challenges in developing a standardized bra cup system, the most significant being that bra cup sizes are a continuum. Women's breasts occur as a fluid range of shapes, sizes, and volumes. Patients have specific expectations regarding bra cup size, and failure to achieve expectations remains the leading cause of patient dissatisfaction. Implant selection that determines eventual bra cup size is critical in patient education and management of patient expectations; however, this is not achievable until all speak the same bra cup language. Patient and surgeon perceptions may never be exact, but it is important to establish guidelines and standards to bridge this gap. PMID:26408432

  18. Quantitative Computerized Assessment of the Degree of Acetabular Bone Deficiency: Total radial Acetabular Bone Loss (TrABL).

    PubMed

    Gelaude, Frederik; Clijmans, Tim; Delport, Hendrik

    2011-01-01

    A novel quantitative, computerized, and, therefore, highly objective method is presented to assess the degree of total radical acetabular bone loss. The method, which is abbreviated to "TrABL", makes use of advanced 3D CT-based image processing and effective 3D anatomical reconstruction methodology. The output data consist of a ratio and a graph, which can both be used for direct comparison between specimens. A first dataset of twelve highly deficient hemipelves, mainly Paprosky types IIIB, is used as illustration. Although generalization of the findings will require further investigation on a larger population, it can be assumed that the presented method has the potential to facilitate the preoperative use of existing classifications and related decision schemes for treatment selection in complex revision cases. PMID:22013539

  19. America's Cup yacht racing: race analysis and physical characteristics of the athletes.

    PubMed

    Neville, Vernon; Calefato, Julian; Pérez-Encinas, Cristina; Rodilla-Sala, Enrique; Rada-Ruiz, Sergio; Dorochenko, Paul; Folland, Jonathan P

    2009-07-01

    The America's Cup is the oldest competing trophy in sport, yet little is known of the nature and intensity of racing or the physical characteristics of the athletes. In this study, aspects of the physical demands of America's Cup yacht racing were analysed, including the intensity of exercise and activity pattern of "grinding". Anthropometric data were collected from 92 professional male America's Cup sailors, and fitness data from a top-4 and a lower-7 ranking team during the 32nd America's Cup. Over the 135 races, mean race duration was 82 min (s = 9), with 20 tacks (s = 10) and 8 gybes (s = 3) per race. Grinding bouts were 5.5 s (s = 5.4; range: 2.2-66.3) long, with 143 exercise bouts per race and an exercise-to-rest ratio of 1:6. Mean and peak heart rate was 64% and 92% of maximum for all positions, with bowmen highest (71% and 96%). Grinders were taller, heavier, and stronger than all other positions. Body fat was similar between positions (13%, s = 4). The higher-standard team was stronger and had greater strength endurance, which probably contributed to their quicker manoeuvres. Intensity of exercise was dependent on the similarity of competing boats and the role of the athlete. The short duration and intermittent nature of grinding is indicative of predominantly anaerobic energy provision. PMID:19629841

  20. Management of knee osteoarthritis with cupping therapy.

    PubMed

    Khan, Asim Ali; Jahangir, Umar; Urooj, Shaista

    2013-10-01

    The study aimed to evaluate the effect of cupping therapy at a clinical setting for knee osteoarthritis. A randomized, controlled clinical trial was conducted. Cupping was performed on 0-6(th) day; 9-11(th) day and 14(th) day, i.e., 11 sittings follow-up to determine longer term carryover of treatment effects utilizing both objective and subjective assessment. The assessment was performed before and after treatment spreading over a period of 15 days. The results of this study shows significant and better results in the overall management of knee osteoarthritis, particularly in relieving pain, edema, stiffness and disability. The efficacy of treatment with cupping therapy in relieving signs and symptoms of knee osteoarthritis is comparable to that of acetaminophen 650 mg thrice a day orally, in terms of analgesia, anti-inflammatory and resolution of edema with minimal and temporary side-effects like echymosis and blister formation while as control drug has greater side-effects particularly on upper gastrointestinal tract. It is recommended that further studies are conducted with a larger study samples and of longer duration. PMID:24350053

  1. Porous-coated acetabular components with screw fixation. Five to ten-year results.

    PubMed

    Latimer, H A; Lachiewicz, P F

    1996-07-01

    The results of 136 consecutive primary total hip arthroplasties performed by one surgeon with the Harris-Galante-I porous-coated acetabular component were reviewed at a mean of seven years (range, five to ten years). In all hips, the outer diameter of the acetabular component was the same as the diameter of the final reamer used in the preparation of the acetabulum. However, this reamer was used only briefly at the rim of the acetabulum, and therefore the components had so-called press-fit stability. A mean of four screws (range, three to six screws) were used for additional fixation of the component. The clinical evaluation was performed with use of the Harris hip score. Standardized anteroposterior radiographs of the pelvis were assessed for migration of the component, radiolucent and radiodense lines, linear wear of the polyethylene, and osteolysis. No acetabular component had been revised for loosening and none were radiographically loose at the time of the most recent follow-up evaluation. There were no complications related to the use of the screws, and no screw had bent or broken. A non-progressive radiolucent line was seen in one acetabular zone in thirty-four hips (25 per cent) and in two acetabular zones in six hips (4 per cent). No hip had a radiolucent line in all three acetabular zones. The mean rate of linear wear of the polyethylene was 0.1 millimeter per year. There was no dissociation of the acetabular liner from the metal shell. Two hips (1 per cent) had asymptomatic osteolysis in the ischium and adjacent to the rim of the acetabular component; this was treated with grafting at the site of the lesion and exchange of the femoral head and the worn polyethylene liner. Five femoral components inserted without cement and one inserted with cement were revised because of loosening. The data suggest that, at a mean of seven years, fixation of this porous-coated component was uniformly excellent. The low prevalence of radiolucent lines and the absence of

  2. Radiological evaluation of acetabular erosion after antibiotic-impregnated polymethylmethacrylate spacer (Spacer-G).

    PubMed

    García-Oltra, Ester; Bori, Guillem; Tomas, Xavier; Gallart, Xavier; Garcia, Sebastian; Soriano, Alex

    2013-06-01

    Different types of hip spacers have been described (hand-made, custom-molded or prefabricated) for treatment of a chronic hip infection. A potential disadvantage of monoblock prefabricated spacer is that it may cause acetabular bone loss. This study assesses the radiological acetabular erosion using an antibiotic-impregnated pre-fabricated polymethylmethacrylate Spacer-G. We retrospectively reviewed the radiographs of thirty five patients who were managed with Spacer-G to treat chronic hip infection. No acetabular erosion were observed in thirty two patients with a mean time from the first to second stage and from the first to the last radiograph of 5.09 and 3.77 months respectively. In three patients the time between the radiographs was more than one year and the second stage was not performed; two developed a protrusion acetabuli whereas the other one a destruction of the acetabular roof. Using a Spacer-G in chronic hip infection treatment for less than one year is not associated with radiological acetabular erosion if the patient is maintained at partial weight bearing. PMID:23142448

  3. Cement as a locking mechanism for screw heads in acetabular revision shells - a biomechanical analysis.

    PubMed

    Laflamme, G Y; Alami, G B; Zhim, F

    2008-01-01

    In acetabular revisions, polyethylene (PE) liners are often cemented into metal shells on top of acetabular screw heads. This study investigates the possibility of using this technique to obtain fixed-angle acetabular screws Eth a concept that has not yet been reported in the literature. Two groups of screws (n=8) were inserted into Trabecular Metal revision shells (Zimmer), into which PE liners were then cemented. Screws in Group 1, inserted in the shell's pre-fabricated holes, were countersunk, whereas screws in Group 2 were inserted in custom-drilled holes that make their heads protrude into, and interdigitate with, the overlying cement mantle. Perpendicular loading was then applied to the screw shafts both statically to failure and cyclically. A greater stiffness was observed for the protruding screws upon static loading; and while the countersunk screws all failed at the screw-cement junction (53.44 + or - 8.33 N), the protruding screws all failed at the screw shaft (1049.79 + or - 32.12 N) a 20-fold difference (p< 0.05). Under cyclic loading, only the protruding screw head specimen did not fail, undergoing an overall displacement within the limits of osseointegration.These results support the hypothesis that the protrusion of an acetabular screw head into an overlying cement mantle significantly increases its angular stability. Provided other variables are favorable, this locking effect may increase the initial stability of the whole implant, thus improving the ultimate success of complex acetabular revisions. PMID:18645971

  4. Ten-year follow-up of the non-porous Allofit cementless acetabular component.

    PubMed

    Zenz, P; Stiehl, J B; Knechtel, H; Titzer-Hochmaier, G; Schwagerl, W

    2009-11-01

    Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation. This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final follow-up at a mean of 10.1 years (8.9 to 11.9). The Harris Hip Score improved from a mean 53 points (23 to 73) pre-operatively to a mean of 96 points (78 to 100) at final review. The osseointegration of all acetabular components was radiologically evaluated with no evidence of loosening. The survival rate with revision of the component as the endpoint was 97.5% (95% confidence interval 94 to 100) after 11.9 years. Radiolucency was found in one DeLee-Charnley zone in four acetabular components. None of the implants required revision for aseptic loosening. Two patients were treated for infection, one requiring a two-stage revision of the implant. One femoral stem was revised for osteolysis due to the production of metal wear debris, but the acetabular shell did not require revision. This study demonstrates that a non-porous titanium acetabular component with adjunct surface fixation offers an alternative to standard porous-coated implants. PMID:19880887

  5. Analytic methods in assessment of optic nerve cupping.

    PubMed

    Jindra, L F; Kuběna, T; Gaudino, R N

    2014-06-01

    The intent of this paper is to provide a systems-based analysis of the methods used to evaluate optic nerve cupping, identify potential flaws in these systems, and propose alternatives better to assess this anatomic quantity. Estimation of optic nerve cupping requires an analytic understanding of both the psychophysical as well as the mathematical bases inherent in this measure. When the (decimal-based) cup-to-disc ratio is used to quantitate optic nerve cupping, a one-dimensional, linear estimate is produced, which in turn is derived from two- or three-dimensional, non-linear physical quantities of area or volume, respectively. When extrapolating from volume, to area, to linear measures, due to the psychophysical constraints which limit this task, such a data-compressed estimate of optic nerve cupping may neither accurately reflect, nor correctly represent, the true amount of cupping actually present in the optic nerve head. This type of one-dimensional metric (when comparing calculations from two- or three-dimensional measures over a range of optic nerve cupping), appears to introduce errors which, while most pronounced earlier on in the disease progression, often overestimate the amount of relative cupping (percent cupping) present in a pathological process like glaucoma. The same systemic errors can also lead to overestimation of the progression in cupping, especially in optic nerves with low cup-to disc values. To provide clinically meaningful estimates of optic nerve cupping, the practitioner needs to be aware of psychophysical and mathematical limitations inherent in using a linear cup-to-disc ratio to estimate the amount of cupping observed in a physical structure like the optic disc. The resultant flaws introduced by observer extrapolation from three, to two, to one dimensions (volume, area, and linear); transposition from non-linear to linear quantities; and optical illusions, caused by factors like disc topology, morphology, and ametropia, can all

  6. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... uncemented acetabular component, prosthesis. 888.3330 Section 888.3330 Food and Drugs FOOD AND DRUG..., prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The...

  7. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... uncemented acetabular component, prosthesis. 888.3330 Section 888.3330 Food and Drugs FOOD AND DRUG..., prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The...

  8. Femtoliter silver cups as surface enhanced Raman scattering active containers.

    PubMed

    Bhuvana, T; Kulkarni, G U

    2009-01-28

    Femtoliter capacity Ag cups formed by the pulsed laser ablation of an Ag foil have been tried out as substrates for surface enhanced Raman scattering (SERS) measurements. The cups are formed as the impinging droplets from the laser plume undergo a flow pattern before freezing into cup-like structures, resulting in a surface roughness (approximately 35 nm) that makes them ideal for SERS studies. The internal volume of the cups is in the femtoliter (10(-15) l) range, well suited for small-scale reactions, particularly in biological studies. The cups exhibit enhancement factors of the order of 10(6) with the analyte molecule thiophenol. Individual cups have been dosed attoliter quantities (10(-18) l) of the analyte and detected. PMID:19417320

  9. The Sphere Anemometer - A Fast Alternative to Cup Anemometry

    NASA Astrophysics Data System (ADS)

    Heißelmann, Hendrik; Hölling, Michael; Peinke, Joachim

    The main problem of cup anemometry is the different response time for increasing and decreasing wind velocities due to its moment of inertia. This results in an overestimation of wind speed under turbulent wind conditions, the so-called over-speeding. Additionally, routine calibrations are necessary due to the wear of bearings. Motivated by these problems the sphere anemometer, a new simple and robust sensor for wind velocity measurements without moving parts, was developed at the University of Oldenburg. In contrast to other known thrust-based sensors, the sphere anemometer uses the light pointer principle to detect the deflection of a bending tube caused by the drag force acting on a sphere mounted at its top. This technique allows the simultaneous determination of wind speed and direction via a two-dimensional position sensitive detector.

  10. Clad vent set cup closure-weld-zone grinding evaluation

    SciTech Connect

    Ulrich, G.B.; Woods, A.T.; Ohriner, E.K.

    1996-04-01

    Clad vent set (CVS) cups were ground in the closure-weld zone to reduce the wall-thickness variation created by the cup deep-drawing process. A significantly more uniform wall thickness would be beneficial for the CVS closure-weld operation. The goal was to reduce the average within-cup wall-thickness variation (defined as the range of wall thicknesses in the closure-weld zone) approximately 50% from the Cassini production value of 42 {micro}m. This goal was shown to be achievable but, unfortunately, not with the existing blank and formed cup thicknesses.

  11. Robust multi-scale superpixel classification for optic cup localization.

    PubMed

    Tan, Ngan-Meng; Xu, Yanwu; Goh, Wooi Boon; Liu, Jiang

    2015-03-01

    This paper presents an optimal model integration framework to robustly localize the optic cup in fundus images for glaucoma detection. This work is based on the existing superpixel classification approach and makes two major contributions. First, it addresses the issues of classification performance variations due to repeated random selection of training samples, and offers a better localization solution. Second, multiple superpixel resolutions are integrated and unified for better cup boundary adherence. Compared to the state-of-the-art intra-image learning approach, we demonstrate improvements in optic cup localization accuracy with full cup-to-disc ratio range, while incurring only minor increase in computing cost. PMID:25453464

  12. The results of acetabular impaction grafting in 129 primary cemented total hip arthroplasties.

    PubMed

    Wilson, Matthew J; Whitehouse, Sarah L; Howell, Jonathan R; Hubble, Matthew J W; Timperley, A John; Gie, Graham A

    2013-09-01

    Between 1995 and 2003, 129 cemented primary THAs were performed using full acetabular impaction grafting to reconstruct acetabular deficiencies. These were classified as cavitary in 74 and segmental in 55 hips. Eighty-one patients were reviewed at mean 9.1 (6.2-14.3) years post-operatively. There were seven acetabular component revisions due to aseptic loosening, and a further 11 cases that had migrated >5mm or tilted >5° on radiological review - ten of which reported no symptoms. Kaplan-Meier analysis of revisions for aseptic loosening demonstrates 100% survival at nine years for cavitary defects compared to 82.6% for segmental defects. Our results suggest that the medium-term survival of this technique is excellent when used for purely cavitary defects but less predictable when used with large rim meshes in segmental defects. PMID:23523217

  13. Biomechanical Analysis of the Fixation System for T-Shaped Acetabular Fracture

    PubMed Central

    Fan, Yanping; Lei, Jianyin; Zhu, Feng; Li, Zhiqiang; Chen, Weiyi; Liu, Ximing

    2015-01-01

    This study aims to evaluate the biomechanical mechanism of fixation systems in the most frequent T-shaped acetabular fracture using finite element method. The treatment of acetabular fractures was based on extensive clinical experience. Three commonly accepted rigid fixation methods (double column reconstruction plates (P × 2), anterior column plate combined with posterior column screws (P + PS), and anterior column plate combined with quadrilateral area screws (P + QS)) were chosen for evaluation. On the basis of the finite element model, the biomechanics of these fixation systems were assessed through effective stiffness levels, stress distributions, force transfers, and displacements along the fracture lines. All three fixation systems can be used to obtain effective functional outcomes. The third fixation system (P + QS) was the optimal method for T-shaped acetabular fracture. This fixation system may reduce many of the risks and limitations associated with other fixation systems. PMID:26495030

  14. Demonstrated Performance of the Solar Probe Cup

    NASA Astrophysics Data System (ADS)

    Case, A. W.; Kasper, J. C.; Korreck, K. E.; Stevens, M. L.; Daigneau, P.; Freeman, M.; Caldwell, D.; Gauron, T.; Wright, K. H.; Bergner, H.; Cirtain, J. W.; Larson, D.; Brodu, E.; Balat-Pichelin, M.

    2013-12-01

    The Solar Probe Cup (SPC) is a Faraday Cup being developed for the Solar Probe Plus (SPP) mission. SPP will be the first spacecraft to directly measure the solar environment near the Alfven point in the atmosphere of the Sun, approaching to within 10 solar radii of the center of the Sun. In order to make the observations of radially flowing solar wind needed to address questions of coronal and solar wind heating and acceleration, SPC must operate while looking directly at the Sun. As a result, SPC will face a harsh and unprecidented environment, with component temperatures exceeding 1000C at closest approach. SPC is similar in design and operation to the two Faraday Cup instruments on the Wind spacecraft, which have been making stable measurements of the solar wind near Earth for two decades, with two key differences. SPC must survive and operate at extreme temperatures due to the levels of solar flux near the Sun, and it must record the solar wind approximately one thousand times faster than the instruments on Wind to keep up with the rapid variations expected near the Sun. We present results of a demonstration model of SPC operated in laboratory reproductions of the near-Sun environment. In the last year, SPC has been exposed to simulated encounter solar fluxes and resulting temperature profiles using a vaccum chamber and modified IMAX film projectors. In addition, SPC has been exposed to realistic ion beams. We show that SPC can operate in these environments, and make the measurements required for the sucess of the Solar Probe mission. Based on the performance of our prototype, the expected cadence and sensitivity of SPC will be discussed, with a focus on its ability to distinguish between models of heating in the solar corona.

  15. Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

    SciTech Connect

    Kachelriess, Marc; Sourbelle, Katia; Kalender, Willi A.

    2006-05-15

    We propose an empirical cupping correction (ECC) algorithm to correct for CT cupping artifacts that are induced by nonlinearities in the projection data. The method is raw data based, empirical, and requires neither knowledge of the x-ray spectrum nor of the attenuation coefficients. It aims at linearizing the attenuation data using a precorrection function of polynomial form. The coefficients of the polynomial are determined once using a calibration scan of a homogeneous phantom. Computing the coefficients is done in image domain by fitting a series of basis images to a template image. The template image is obtained directly from the uncorrected phantom image and no assumptions on the phantom size or of its positioning are made. Raw data are precorrected by passing them through the once-determined polynomial. As an example we demonstrate how ECC can be used to perform water precorrection for an in vivo micro-CT scanner (TomoScope 30 s, VAMP GmbH, Erlangen, Germany). For this particular case, practical considerations regarding the definition of the template image are given. ECC strives to remove the cupping artifacts and to obtain well-calibrated CT values. Although ECC is a first-order correction and cannot compete with iterative higher-order beam hardening or scatter correction algorithms, our in vivo mouse images show a significant reduction of bone-induced artifacts as well. A combination of ECC with analytical techniques yielding a hybrid cupping correction method is possible and allows for channel-dependent correction functions.

  16. NCI Holds on to Defelice Cup | Poster

    Cancer.gov

    NCI kept the Defelice Cup trophy this year after beating Leidos Biomedical Research, 15 to 9, at the 10th annual Ronald H. Defelice Golf Tournament held on Columbus Day. Sixteen players on each team battled it out at the yearly contractor vs. government tournament held at Rattlewood Golf Course in Mount Airy, Md. NCI leads the series 6–4. “The score was the highest NCI margin of victory in the 10-year series,” said Denny Dougherty, retired senior subcontracts advisor at what was formerly SAIC-Frederick. “The intensity of the annual competition has increased each year and has become...

  17. Benchmark 4 - Wrinkling during cup drawing

    NASA Astrophysics Data System (ADS)

    Dick, Robert; Cardoso, Rui; Paulino, Mariana; Yoon, Jeong Whan

    2013-12-01

    Benchmark-4 is designed to predict wrinkling during cup drawing. Two different punch geometries have been selected in order to investigate the changes of wrinkling amplitude and wave. To study the effect of material on wrinkling, two distinct materials including AA 5042 and AKDQ steel are also considered in the benchmark. Problem description, material properties, and simulation reports with experimental data are summarized. At the request of the author, and Proceedings Editor, a corrected and updated version of this paper was published on January 2, 2014. The Corrigendum attached to the updated article PDF contains a list of the changes made to the original published version.

  18. [Acetabular fractures in the elderly. Outcome of open reduction and internal fixation].

    PubMed

    Tosounidis, G; Culemann, U; Bauer, M; Holstein, J H; Garcia, P; Kurowski, R; Pizanis, A; Aghayev, E; Pohlemann, T

    2011-08-01

    The aim of this study was to analyze the clinical outcome and incidence of hip arthritis in elderly patients with acetabular fractures. Because of poor bone quality in the elderly, even a low-energy trauma may lead to an acetabular fracture. An anatomical reconstruction of the acetabulum is necessary to achieve sufficient stability also for a potential hip arthroplasty. So far, there is very limited information on the outcome of acetabular fractures in the elderly. During a period of 6 years (2001-2006), 48 patients older than 60 years were admitted to our department with an acetabular fracture. Thirty-nine patients were treated operatively and nine patients non-operatively. Twenty-nine operatively treated patients were followed up. Nineteen of them were assessed using EQ-5D, SF-12 and Merle d'Aubigné questionnaires in addition to their clinical examination. Ten other surgical patients were only examined using the questionnaires. Of the 29 patients that were followed up, 5 underwent total hip arthroplasty due to secondary post-traumatic hip arthritis after open reduction and internal fixation (ORIF). The range of motion of the operated hip was comparable to that of the non-operated contralateral side. However, the internal rotation was found to be slightly decreased at the operated side when compared to the non-operated contralateral side. Merle d'Aubigné score and physical and mental SF-12 score components as well as quality of life were better in patients treated with ORIF compared to those patients that were treated by secondary hip arthroplasty. Regarding the different treatment strategies (ORIF vs primary hip arthroplasty vs non-operative treatment) of acetabular fractures in the elderly, data from the literature are conflicting. Our results indicate that ORIF represents a good treatment option for acetabular fractures in the elderly. In patients that did not develop secondary hip arthritis, a good clinical outcome and quality of life was documented. PMID

  19. Acetabular labral tears: focused review of anatomy, diagnosis, and current management.

    PubMed

    Huang, Ronald; Diaz, Claudio; Parvizi, Javad

    2012-05-01

    Acetabular labral tears have become an increasingly common diagnosis with the advancement of imaging techniques and hip arthroscopy. Therefore, understanding the anatomic significance, healing potential, and associated pathologies of labral tears is helpful. Furthermore, recognizing the clinical picture and understanding appropriate imaging techniques, such as magnetic resonance arthrography, are essential to making a correct diagnosis. This article reviews the relevant anatomy, diagnosis, and management of acetabular labral tears for physicians of all specialties who may be involved in the care of patients with labral tears. Short-term results of labral repair have been promising, but further studies are needed to clarify appropriate indications and long-term results of treatment. PMID:22759609

  20. Methods and Guidelines for Venous Thromboembolism Prevention in Polytrauma Patients with Pelvic and Acetabular Fractures

    PubMed Central

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Haro, José Antonio Calvo; Vaquero-Martín, Javier

    2015-01-01

    Sequential compression devices and chemical prophylaxis are the standard venous thromboembolism (VTE) prevention for trauma patients with acetabular and pelvic fractures. Current chemical pharmacological contemplates the use of heparins or fondaparinux. Other anticoagulants include coumarins and aspirin, however these oral agents can be challenging to administer and may need monitoring. When contraindications to anticoagulation in high-risk patients are present, prophylactic inferior vena cava filters can be an option to prevent pulmonary emboli. Unfortunately strong evidence about the most effective method, and the timing of their commencement, in patients with pelvic and acetabular fractures remains controversial. PMID:26312115

  1. Thermoregulatory demands of elite professional America's Cup yacht racing.

    PubMed

    Neville, V; Gant, N; Folland, J P

    2010-06-01

    America's Cup yacht racing predominantly occurs during the summer months under hot and humid conditions, with athletes exposed to the environment for prolonged periods, and yet the thermoregulatory responses to competitive sailing are largely unappreciated. This study aimed to assess the thermoregulatory responses to elite professional big-boat yacht racing, according to crew position and upwind and downwind sailing. Intestinal (T(core)) and skin temperature, fluid balance and regional sweat compositions were measured in two America's Cup crews (n=32) during 100 min of racing. The environmental conditions were as follows: 32 degrees C, 52% RH and 5 m/s wind speed. Subjective race intensity was moderate. Bowmen recorded the greatest elevation in the heart rate (184 +/- 10 beats/min) and T(core) (39.2 degrees C, P<0.01). Both heart rate and T(core) were higher during downwind sailing (P<0.001). Regional skin temperatures were significantly different according to site (P=0.05), with tibia being the lowest (33.3 +/- 1.2 degrees C). The mean sweat loss during racing was 1.34 +/- 0.58 L/h (range: 0.44-2.40 L/h), with bowmen experiencing the greatest loss of sweat (3.7 +/- 0.9% of body mass). The mean fluid intake was highly correlated to sweat loss (r=0.74, P<0.001), with 72 +/- 41% of sweat losses replaced. The mean sodium concentration of sweat was 27.2 +/- 9.2 mmol/L (range: 12.0-43.5 mmol/L) and the total NaCl loss during sailing was 3.8 +/- 2.4 g (range 0.7-10.0 g). America's Cup sailing is a demanding sport that presents considerable challenges to thermoregulation, fluid and electrolyte balance. Certain crew roles (bowmen) present an increased risk of developing exertional heat illness, and for the majority of crew downwind sailing results in greater thermal strain than upwind sailing - which may have implications for clothing selection and boat design. PMID:19558386

  2. Polystyrene cups and containers: styrene migration.

    PubMed

    Tawfik, M S; Huyghebaert, A

    1998-07-01

    The level of styrene migration from polystyrene cups was monitored in different food systems including: water, milk (0.5, 1.55 and 3.6% fat), cold beverages (apple juice, orange juice, carbonated water, cola, beer and chocolate drink), hot beverages (tea, coffee, chocolate and soup (0.0, 0.5, 1, 2, and 3.6% fat), take away foods (yogurt, jelly, pudding and ice-cream), as well as aqueous food simulants (3% acetic acid, 15, 50, and 100% ethanol) and olive oil. Styrene migration was found to be strongly dependent upon the fat content and storage temperature. Drinking water gave migration values considerably lower than all of the fatty foods. Ethanol at 15% showed a migration level equivalent to milk or soup containing 3.6% fat. Maximum observed migration for cold or hot beverages and take-away foods was 0.025% of the total styrene in the cup. Food simulants were responsible for higher migration (0.37% in 100% ethanol). A total of 60 food samples (yogurt, rice with milk, fromage, biogardes, and cheese) packed in polystyrene containers were collected from retail markets in Belgium, Germany, and the Netherlands. The level of styrene detected in the foods was always fat dependent. PMID:9829045

  3. Biomechanical Study of Acetabular Tridimensional Memoryalloy Fixation System

    NASA Astrophysics Data System (ADS)

    Liu, Xin-Wei; Xu, Shuo-Gui; Zhang, Yun-Tong; Zhang, Chun-Cai

    2011-07-01

    We developed the acetabular tridimensional memoryalloy fixation system (ATMFS), which is made of NiTi shape memory alloy, according to the specific mechanical properties of biological memory material, NiTi shape memory alloy and measured distribution of contact area and pressure between the acetabulum and the femoral head of cadaveric pelvis. Seven formalin-preserved cadaveric pelves were used for this investigation. Pressure-sensitive film was used to measure contact area and pressure within the anterior, superior, and posterior regions of the acetabulum. The pelves were loaded under the following four conditions: (1) intact; (2) following a creation posterior wall fracture defect; (3) following reduction and standard internal fixation with reconstruction plate; and (4) following reduction and internal fixation with a new shape memory alloy device named ATMFS. A posterior wall fracture was created along an arc of 40° to 90° about the acetabulur rim. Creation of a posterior wall defect resulted in increased load in the superior acetabulum (1485 N) as compared to the intact condition (748 N, P = 0.009). Following reduction and internal fixation, the load distributed to the superior acetabulum (1545 N) was not statistically different from the defect condition. Following the fixation with ATMFS, the load seen at the superior region of the actabulum (964 N) was familiar with fixation with reconstruction plate and was not different from intact state ( P = 0.45). These data indicate that the use of ATMFS as a fracture internal fixation device resulted a partial restoration of joint loading parameters toward the intact state. ATMFS fixation may result in a clinical benefit.

  4. Remodeling of secretory compartments creates CUPS during nutrient starvation.

    PubMed

    Cruz-Garcia, David; Curwin, Amy J; Popoff, Jean-François; Bruns, Caroline; Duran, Juan M; Malhotra, Vivek

    2014-12-22

    Upon starvation, Grh1, a peripheral membrane protein located at endoplasmic reticulum (ER) exit sites and early Golgi in Saccharomyces cerevisiae under growth conditions, relocates to a compartment called compartment for unconventional protein secretion (CUPS). Here we report that CUPS lack Golgi enzymes, but contain the coat protein complex II (COPII) vesicle tethering protein Uso1 and the Golgi t-SNARE Sed5. Interestingly, CUPS biogenesis is independent of COPII- and COPI-mediated membrane transport. Pik1- and Sec7-mediated membrane export from the late Golgi is required for complete assembly of CUPS, and Vps34 is needed for their maintenance. CUPS formation is triggered by glucose, but not nitrogen starvation. Moreover, upon return to growth conditions, CUPS are absorbed into the ER, and not the vacuole. Altogether our findings indicate that CUPS are not specialized autophagosomes as suggested previously. We suggest that starvation triggers relocation of secretory and endosomal membranes, but not their enzymes, to generate CUPS to sort and secrete proteins that do not enter, or are not processed by enzymes of the ER-Golgi pathway of secretion. PMID:25512390

  5. Nutrient disorders of 'Evolution' mealy-cup sage

    Technology Transfer Automated Retrieval System (TEKTRAN)

    To produce popular floriculture crops like mealy-cup sage (Salvia farinacea (Benth.)), growers must be equipped with cultural information including the ability to recognize and characterize disorders. Diagnostic criteria of nutrient disorders of mealy-cup sage are absent from the literature. Theref...

  6. A critical comparison of ten disposable cup LCAs

    SciTech Connect

    Harst, Eugenie van der; Potting, José

    2013-11-15

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) also shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches.

  7. Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements.

    PubMed

    Alshuhri, Abdullah A; Holsgrove, Timothy P; Miles, Anthony W; Cunningham, James L

    2015-08-01

    Current techniques for diagnosing early loosening of a total hip replacement (THR) are ineffective, especially for the acetabular component. Accordingly, new, accurate, and quantifiable methods are required. The aim of this study was to investigate the viability of vibrational analysis for accurately detecting acetabular component loosening. A simplified acetabular model was constructed using a Sawbones(®) foam block. By placing a thin silicone layer between the acetabular component and the Sawbones block, 2- and 4-mm soft tissue membranes were simulated representing different loosening scenarios. A constant amplitude sinusoidal excitation with a sweep range of 100-1500 Hz was used. Output vibration from the model was measured using an accelerometer and an ultrasound probe. Loosening was determined from output signal features such as the number and relative strength of observed harmonic frequencies. Both measurement methods were sufficient to measure the output vibration. Vibrational analysis reliably detected loosening corresponding to both 2 and 4 mm tissue membranes at driving frequencies between 100 and 1000 Hz (p < 0.01) using the accelerometer. In contrast, ultrasound detected 2-mm loosening at a frequency range of 850-1050 Hz (p < 0.01) and 4-mm loosening at 500-950 Hz (p < 0.01). PMID:26054805

  8. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... for use with bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the... metal (hemi-hip) acetabular metal cemented prosthesis shall have an approved PMA or a declared...

  9. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... for use with bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the... metal (hemi-hip) acetabular metal cemented prosthesis shall have an approved PMA or a declared...

  10. Effect of acetabular orientation on stress distribution of highly cross-linked polyethylene liners.

    PubMed

    Lam, Luthan; Drew, Timothy; Boscainos, Petros

    2013-11-01

    Several case reports have documented the fracture of highly cross-linked polyethylene (HCLPE) liners used in total hip arthroplasty (THA). Although uncommon, fractured liners result in considerable morbidity for patients and require revision surgery. One postulated mechanism that leads to this type of implant failure is malorientation of the acetabular component. The purpose of this study was to investigate the effect of acetabular orientation on the stress distribution of HCLPE liners used in THA by means of finite element analysis. Three-dimensional models of a commonly used HCLPE liner were created corresponding to 12 different acetabular component orientations (inclination ranging from 20° to 70° and version ranging from 20° of retroversion to 40° of anteversion). A static stress analysis of the finite element models was performed under conditions simulating peak gait loads. The results of the analysis revealed that excessive inclination and extremes of version were associated with an increase in peak stress magnitudes. The locations of peak stress also were found to lie within the rim notch and locking ring groove regions, which were consistent with the fracture locations reported in published case reports. Therefore, the acetabular component should be oriented carefully during implantation to reduce the risk of rim loading and subsequent liner fracture. In addition, an alternative liner design may further help reduce stress risers and risk of fracture. PMID:24200436

  11. Relationship between developmental dislocation of the hip in infant and acetabular dysplasia at skeletal maturity.

    PubMed

    Okano, Kunihiko; Yamaguchi, Kazumasa; Ninomiya, Yoshikazu; Matsubayashi, Shohei; Aoyagi, Kiyoshi; Osaki, Makoto; Enomoto, Hiroshi; Takahashi, Katsuro

    2015-01-01

    Previous reports demonstrated 8-60% patients treated for developmental dislocation of hip (DDH) in infancy have residual acetabular dysplasia (AD) at skeletal maturity. AD patients reportedly exhibit abnormal morphology of the pelvis, high rates of comorbid spinal congenital anomalies and high bone mineral density. These physical findings suggest that AD patients have genetic background. We examined the percentage of AD patients with hip pain at skeletal maturity having a history of DDH in infancy and the correlation between the severity of AD at skeletal maturity and history of DDH treatment to investigate the relationship between AD and DDH.A total of 245 patients were radiographically examined for any history of DDH treatment in infancy. The study included 226 women and 19 men with a mean age at examination of 40.7 years (range 17-59 years).Eighty-eight patients (36%) had a history of DDH treatment (DDH group) and the remaining 157 patients (64%) had no history of DDH treatment (non-DDH group). The average age was lower and acetabular angle was larger in the DDH group. There was a significant increasing trend of the percentage of DDH patients associated with the severity of AD classified with CE, acetabular angle, and acetabular roof angle.Our data suggest that there are several AD patients without a history of DDH in Japan, and AD in patients without a history of DDH has different characteristics from AD in patients with a history of DDH. PMID:25569642

  12. The effect of incisional negative pressure therapy on wound complications after acetabular fracture surgery.

    PubMed

    Reddix, Robert N; Leng, Xiaoyan Iris'; Woodall, James; Jackson, Benjamin; Dedmond, Barnaby; Webb, Lawrence X

    2010-01-01

    The purpose of the study was to determine if the use of incisional negative pressure therapy affected the rate of wound complications after acetabular fracture surgery. Between August 1996 to April 2005, 301 patients were found to have had an operatively treated acetabular fracture. There were 235 patients who had placement of incisional vacuum-assisted closure (VAC) who had three (1.27%) deep wound infections and one (0.426%) wound dehiscence. There were 66 consecutive patients who were available in the 5 years preceding the usage of the incisional VAC who had four (6.06%) deep wound infections and two (3.03%) wound dehiscences. This is less than the published infection rate of 4% for patients undergoing operative treatment of acetabular fractures and less than the authors' rate of 6.15% in the time period before the use of the incisional negative pressure wound therapy (p=.0414). The use of incisional negative pressure wound therapy significantly decreases perioperative wound complications after acetabular fracture surgery. PMID:20727304

  13. Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty

    PubMed Central

    Manzano, Givenchy; Levin, Rayna A. C.; Mayor, Michael B.; Schwarzkopf, Ran

    2014-01-01

    Introduction: Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied extensively, however, only few reports have described its catastrophic wear. We report such a case of complete wear of the acetabular liner in a ceramic-on-polyethylene prosthesis in a 57-year adult male. Case Report: A 57-year adult male with a history of bilateral total hip arthroplasty presented to our institution with bilateral hip pain worst on the right. Range of motion was limited by pain on the right hip at the extremes of motion. Radiographs revealed severe osteolysis, heterotopic ossification, complete wear of the acetabular liner, bony impingement of the femoral greater trochanter on the acetabular rim and superior migration of the femoral head. All findings were confirmed intraoperatively. Revision of the acetabular components was performed, which successfully alleviated the patient’s symptoms. Conclusion: Failure of the ceramic-on-polyethylene liner in our patient is due to the use of a non-cross linked polyethylene liner, a highly active lifestyle, and poor follow up. Arthroplasty surgeons should be aware of this complication especially in highly active patients with a conventional polyethylene liner and chronic hip pain. PMID:27298960

  14. Surgical dislocation of the hip for the fixation of acetabular fractures.

    PubMed

    Tannast, M; Krüger, A; Mack, P W; Powell, J N; Hosalkar, H S; Siebenrock, K A

    2010-06-01

    Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis. PMID:20513883

  15. Thin-Walled Cross-Linked Acetabular Liners Need Not Exhibit Reduced Locking Strength.

    PubMed

    Murtha, Andrew S; Roy, Marcel E; Whiteside, Leo A; Tilden, David S; Schmitt, Krystal L

    2015-08-01

    Use of larger diameter femoral heads has emerged as a promising strategy to reduce the risk of dislocation after total hip arthroplasty, but thinning the walls of cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) acetabular liners to accommodate these larger heads may compromise the locking mechanism of the liner. The purpose of this study was to test the mechanical integrity of the locking mechanism in cross-linked and re-melted UHMWPE acetabular components with reduced wall thickness. The locking mechanism of cross-linked (100 kGy/re-melted) acetabular liners in sizes 50/28, 50/36, and 52/36 mm of 1 design was evaluated by lever-out tests and torsion tests. Torsion tests were performed at 2 angles to isolate the liner's locking tabs independent of the contribution of its central post. Lever-out testing demonstrated nominally reduced failure strength in 50/36-mm liners (13.3 N · m) compared with 50/28-mm liners (12.3 N · m; P=.0502), whereas the lever-out strength of 52/36-mm liners was 12.2±0.94 N · m. Failure torques were similar between 50/28- and 50/36-mm liners at 45° and 90°, but the failure torque of size 52/36-mm liners was significantly higher at each angle. The use of larger diameter femoral heads does not compromise the locking mechanism of thinned MicroSeal (Signal Medical Corp, Marysville, Michigan) acetabular liners. Use of a cross-linked UHMWPE acetabular liner, with a locking mechanism that is not compromised when the liner is thinned to a thickness of at least 2.86 mm, appears to be a biomechanically sound construct when articulated with large diameter femoral heads. PMID:26270761

  16. Feeding Neonates by Cup: A Systematic Review of the Literature.

    PubMed

    McKinney, Christy M; Glass, Robin P; Coffey, Patricia; Rue, Tessa; Vaughn, Matthew G; Cunningham, Michael

    2016-08-01

    Objective WHO and UNICEF recommend cup feeding for neonates unable to breastfeed in low-resource settings. In developed countries, cup feeding in lieu of bottle feeding in the neonatal period is hypothesized to improve breastfeeding outcomes for those initially unable to breastfeed. Our aim was to synthesize the entire body of evidence on cup feeding. Methods We searched domestic and international databases for original research. Our search criteria required original data on cup feeding in neonates published in English between January 1990 and December 2014. Results We identified 28 original research papers. Ten were randomized clinical trials, 7 non-randomized intervention studies, and 11 observational studies; 11 were conducted in developing country. Outcomes evaluated included physiologic stability, safety, intake, duration, spillage, weight gain, any and exclusive breastfeeding, length of hospital stay, compliance, and acceptability. Cup feeding appears to be safe though intake may be less and spillage greater relative to bottle or tube feeding. Overall, slightly higher proportions of cup fed versus bottle fed infants report any breastfeeding; a greater proportion of cup fed infants reported exclusive breastfeeding at discharge and beyond. Cup feeding increases breastfeeding in subgroups (e.g. those who intend to breastfeed or women who had a Caesarean section). Compliance and acceptability is problematic in certain settings. Conclusions Further research on long-term breastfeeding outcomes and in low-resource settings would be helpful. Research data on high risk infants (e.g. those with cleft palates) would be informative. Innovative cup feeding approaches to minimize spillage, optimize compliance, and increase breastfeeding feeding are needed. PMID:27016350

  17. The translational regulator Cup controls NMJ presynaptic terminal morphology.

    PubMed

    Menon, Kaushiki P; Carrillo, Robert A; Zinn, Kai

    2015-07-01

    During oogenesis and early embryonic development in Drosophila, translation of proteins from maternally deposited mRNAs is tightly controlled. We and others have previously shown that translational regulatory proteins that function during oogenesis also have essential roles in the nervous system. Here we examine the role of Cup in neuromuscular system development. Maternal Cup controls translation of localized mRNAs encoding the Oskar and Nanos proteins and binds to the general translation initiation factor eIF4E. In this paper, we show that zygotic Cup protein is localized to presynaptic terminals at larval neuromuscular junctions (NMJs). cup mutant NMJs have strong phenotypes characterized by the presence of small clustered boutons called satellite boutons. They also exhibit an increase in the frequency of spontaneous glutamate release events (mEPSPs). Reduction of eIF4E expression synergizes with partial loss of Cup expression to produce satellite bouton phenotypes. The presence of satellite boutons is often associated with increases in retrograde bone morphogenetic protein (BMP) signaling, and we show that synaptic BMP signaling is elevated in cup mutants. cup genetically interacts with two genes, EndoA and Dap160, that encode proteins involved in endocytosis that are also neuronal modulators of the BMP pathway. Endophilin protein, encoded by the EndoA gene, is downregulated in a cup mutant. Our results are consistent with a model in which Cup and eIF4E work together to ensure efficient localization and translation of endocytosis proteins in motor neurons and control the strength of the retrograde BMP signal. PMID:26102195

  18. Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component.

    PubMed

    John, Thomas K; Ghosh, Gaurav; Ranawat, Chitranjan S; Ranawat, Amar S; Meftah, Morteza

    2015-12-01

    The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5-9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1. There was no interference demarcation in any zones. Two cups were revised (0.9%): one for dislocation and another for infection. The Kaplan-Meier survivorship for cup revision for any failure (infection, dislocation) was 99% and for mechanical failure (osteolysis, loosening) was 100%. This design has excellent safety, efficacy and durability. PMID:26235521

  19. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    PubMed

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. PMID:24559522

  20. [Aseptic, simultaneous and bilateral mobilisation due to an acetabular shell fracture in a 43 year-old patient].

    PubMed

    Ceretti, M; Fanelli, M; Pappalardo, S

    2014-01-01

    The acetabular shell mobilization is the main long-term complication in total hip replacement. Metal-back fracture has also to be considered among the possible causes of shell mobilization. A case is presented of bilateral acetabular shell mobilization due to the trabecular covering de-soldering from the metal-back in a 43 year-old patient, 13-14 years after the first surgery. PMID:24360788

  1. A geometric morphometric analysis of acetabular shape of the primate hip joint in relation to locomotor behaviour.

    PubMed

    San Millán, Marta; Kaliontzopoulou, Antigoni; Rissech, Carme; Turbón, Daniel

    2015-06-01

    The description of acetabular shape variation among primates is essential for our understanding of the locomotor behaviour and ecology of both extant and fossil species. In this study, we use two-dimensional geometric morphometrics to examine variation in acetabular shape in human and non-human primates and to determine the degree to which it co-varies with locomotor behaviour, while taking both intra and inter-specific variation into account. To these ends, we examined the acetabulum of 303 left hip bones of 27 extant genera of primates (including humans) with different locomotor behaviours. After accounting for shape variation due to sex, size, and phylogeny, the results confirm that acetabular shape varies significantly across locomotor groups. The two most differentiated locomotor groups are leapers and slow-climbing quadrupeds, which exhibit a unique acetabular shape. Furthermore, the acetabulum of humans differed significantly from all other groups, while no significant differences existed between chimpanzees and gorillas. The most noticeable differences are detected in both cranial and dorsal areas and around the acetabular horns. This variation in acetabular morphology may have biomechanical implications at the level of the hip joint, potentially determining joint range motion and load distribution during locomotion. Given the increasing number of published studies on fossil pelves, our results are widely applicable to fossil analyses, with critical implications for paleoanthropological analyses about the complex locomotor behaviour of fossil specimens and their classification into locomotor groups, which may enhance our understanding of their ecological habits. PMID:25929707

  2. Space Coffee Cup: Capillary Flow Driven Fluids in Space

    NASA Video Gallery

    Interested in learning more about how fluids react in Space? In this video, Professor Mark Weislogel, and Dr. Marshall Porterfield will discuss the Space Coffee Cup and Capillary Flow Driven Fluids...

  3. Figuring out the Statistics of the ICC World Cup 2011

    ERIC Educational Resources Information Center

    Shiwalkar, Jyoti P.; Deshpande, M. N.

    2013-01-01

    This paper deals with the analysis of cricket match results from the ICC World Cup 2011. We believe that such data provide good material for interesting classroom exercises. (Contains 7 tables and 1 figure.)

  4. Space Experiment Concepts: Cup-Burner Flame Extinguishment

    NASA Technical Reports Server (NTRS)

    Takahashi, Fumiaki

    2004-01-01

    Space Fire Suppression Processes & Technology. Space experiment concepts of cup-burner flame extinguishment have been conceived to address to the key issues (i.e., organizing questions) in space fire suppression. Cup-burner flame extinguishment experiment can reveal physical and chemical suppression processes and provide agent effectiveness data useful for technology development of space fire suppression systems in various reduced-gravity platforms.

  5. A Zero-Gravity Cup for Drinking Beverages in Microgravity

    NASA Technical Reports Server (NTRS)

    Pettit, Donald R.; Weislogel, Mark; Concus, Paul; Finn, Robert

    2011-01-01

    To date, the method for astronauts to drink liquids in microgravity or weightless environments is to suck the liquid from a bag or pouch through a straw. A new beverage cup works in microgravity and allows astronauts to drink liquids from a cup in a manner consistent with that on Earth. The cup is capable of holding beverages with an angled channel running along the wall from the bottom to the lip. In microgravity, a beverage is placed into the cup using the galley dispenser. The angled channel acts as an open passage that contains only two sides where capillary forces move the liquid along the channel until it reaches the top lip where the forces reach an equilibrium and the flow stops. When one sips the liquid at the lip of the channel, the capillary force equilibrium is upset and more liquid flows to the lip from the reservoir at the bottom to re-establish the equilibrium. This sipping process can continue until the total liquid contents of the cup is consumed, leaving only a few residual drops about the same quantity as in a ceramic cup when it is drunk dry on Earth.

  6. Splash-cup plants accelerate raindrops to disperse seeds

    PubMed Central

    Amador, Guillermo J.; Yamada, Yasukuni; McCurley, Matthew; Hu, David L.

    2013-01-01

    The conical flowers of splash-cup plants Chrysosplenium and Mazus catch raindrops opportunistically, exploiting the subsequent splash to disperse their seeds. In this combined experimental and theoretical study, we elucidate their mechanism for maximizing dispersal distance. We fabricate conical plant mimics using three-dimensional printing, and use high-speed video to visualize splash profiles and seed travel distance. Drop impacts that strike the cup off-centre achieve the largest dispersal distances of up to 1 m. Such distances are achieved because splash speeds are three to five times faster than incoming drop speeds, and so faster than the traditionally studied splashes occurring upon horizontal surfaces. This anomalous splash speed is because of the superposition of two components of momentum, one associated with a component of the drop's motion parallel to the splash-cup surface, and the other associated with film spreading induced by impact with the splash-cup. Our model incorporating these effects predicts the observed dispersal distance within 6–18% error. According to our experiments, the optimal cone angle for the splash-cup is 40°, a value consistent with the average of five species of splash-cup plants. This optimal angle arises from the competing effects of velocity amplification and projectile launching angle. PMID:23235266

  7. Collective efficacy at the Rugby World Cup 2015--The role of imagery and observation.

    PubMed

    Shearer, David A

    2015-01-01

    The Rugby World Cup in 2015 will present each competing team with unique psychological challenges not usually encountered in normal international fixtures. In the "pressure-pot" environment of the tournament, teams that have the strongest sense of collective efficacy will most likely perform to their best and respond positively to the outside stressors (e.g., media interest, public expectations). In this review, the importance of collective efficacy to team performance at the World Cup in terms of team resiliency and minimising process losses is discussed. In addition, the relationship between collective efficacy and other psychological factors such as team cohesion is highlighted. From a practical perspective, an introduction to interventions to develop collective efficacy is provided. In particular, the neuroscience evidence for the use of imagery and observation interventions to improve individual collective efficacy perceptions is highlighted. It is emphasised how these interventions are particularly suited to international teams who compete together sporadically. Finally, specific recommendations are made such that practitioners might be able to implement these strategies with their teams before the World Cup. PMID:25913269

  8. Infusing pleasure: Mood effects of the consumption of a single cup of tea.

    PubMed

    Einöther, Suzanne J L; Rowson, Matthew; Ramaekers, Johannes G; Giesbrecht, Timo

    2016-08-01

    Tea has historically been associated with mood benefits. Nevertheless, few studies have empirically investigated mood changes after tea consumption. We explored immediate effects of a single cup of tea up to an hour post-consumption on self-reported valence, arousal, discrete emotions, and implicit measures of mood. In a parallel group design, 153 participants received a cup of tea or placebo tea, or a glass of water. Immediately (i.e. 5 min) after consumption, tea increased valence but reduced arousal, as compared to the placebo. There were no differences at later time points. Discrete emotions did not differ significantly between conditions, immediately or over time. Water consumption increased implicit positivity as compared to placebo. Finally, consumption of tea and water resulted in higher interest in activities overall and in specific activity types compared to placebo. The present study shows that effects of a single cup of tea may be limited to an immediate increase in pleasure and decrease in arousal, which can increase interest in activities. Differences between tea and water were not significant, while differences between water and placebo on implicit measures were unexpected. More servings over a longer time may be required to evoke tea's arousing effects and appropriate tea consumption settings may evoke more enduring valence effects. PMID:27059832

  9. Application of a stereometric structural analysis for an evaluation of surface and for a forecast of the wear of endoprothesis acetabular cups

    SciTech Connect

    Cybo, Jerzy; Maszybrocka, Joanna . E-mail: jmaszybr@us.edu.pl; Cwajna, Jan

    2006-06-15

    To improve the resistance to wear and permanent deformation of polyethylene operating in a polymer/metal friction couple, initial plastic deformation of the polyethylene and its electron irradiation was applied. This contributed to a change of the polymer structure, visible already while machining when the sample surfaces were being prepared for a tribological test. The study shows that the interactions that shape the structure of polyethylene, at the same time cause adequate changes to the stereometric structure of its surface. The parameters of surface microgeometry characterize the future tribological behavior of polyethylene during its operation in a friction couple. It has been shown that an analysis of stereometric parameters may constitute the first projection of polymer wear resistance.

  10. Spontaneous Acetabular Periprosthetic Fracture in a Patient Continuously Having Zoledronic Acid

    PubMed Central

    Tantavisut, Saran; Thanakit, Voranuch; Ngarmukos, Srihatach; Wilairatana, Vajara; Wangroongsub, Yongsak

    2014-01-01

    Zoledronic acid has been used for prevention of osteolytic and osteoblastic bone metastasis. This case report illustrates an undesirable consequence from prolonged usage of zoledronic acid in bone metastasis prevention. Periprosthetic acetabular fracture in a patient treated with zoledronic acid for 7 years was reported. The clinical presentation, radiographic and pathological results were described. This is a rare complication after total hip arthroplasty which should not be ignored especially in patients who received long term bisphosphonate. PMID:25177464

  11. Retrograde Transpubic Approach for Percutaneous Radiofrequency Ablation and Cementoplasty of Acetabular Metastasis

    PubMed Central

    Bauones, Salem; Freire, Veronique; Moser, Thomas P.

    2015-01-01

    We report a case of painful and disabling anterior acetabular bone metastasis treated with bipolar radiofrequency ablation and cementoplasty. Due to the high risk of complications related to the proximity of the femoral neurovascular structures with a direct approach, we successfully performed a retrograde transpubic approach under combined CT and fluoroscopic guidance. In the present report, we describe this approach detailing its indications, advantages, and the technical tips to achieve a safe and satisfactory procedure. PMID:26491595

  12. Custom-made locked plating for acetabular fracture: a pilot study in 24 consecutive cases.

    PubMed

    Xu, Meng; Zhang, Li-Hai; Zhang, Ying-Ze; Zhang, Li-Cheng; He, Chun-Qing; Wang, Yan; Tang, Pei-Fu

    2014-07-01

    Clinical implementation of site-specific locking plates for acetabular fracture remains untested. Custom-made locking plates were manufactured using computer-aided design and computer-aided manufacture techniques for acetabular fractures to test this procedure. The 3-dimensional images constructed from computed tomography data of pelvises in patients with acetabular fractures were used for preoperative planning and to design the plates. Data for each plate were input into software for programming, and the generated code was transferred into a computerized numerical control digital milling machine for manufacturing. These plates were clinically implemented, and the implementation parameters, reduction quality, and Postel Merle d'Aubigné score were evaluated. Forty-nine custom-made locking plates were manufactured for 24 unilateral acetabular fractures. The manufacturing process for the plates averaged 6.9±2.2 days. Processing the plates delayed operations by 2.6±1.3 days in one-third of the cases. Plate contouring was avoided in 48 plates. The plates had anatomical shapes, excellently matching reduced bone surface. The screws locked with the obtained plates avoided intra-articular penetration and provided secure fixation that allowed early out-of-bed rehabilitation. No indications of implant failures or observations of screw back-outs were observed during follow-up. The clinical application of such plates is associated with the avoidance of plate contouring, low risk of intra-articular penetration, early out-of-bed rehabilitation, and a low rate of implant failure. Implementing such plates in clinical practice is worthy of further investigation, with a focus on selecting patient population and minimizing the time required for and cost of plate manufacturing. PMID:24992064

  13. Articular cartilage friction increases in hip joints after the removal of acetabular labrum.

    PubMed

    Song, Yongnam; Ito, Hiroshi; Kourtis, Lampros; Safran, Marc R; Carter, Dennis R; Giori, Nicholas J

    2012-02-01

    The acetabular labrum is believed to have a sealing function. However, a torn labrum may not effectively prevent joint fluid from escaping a compressed joint, resulting in impaired lubrication. We aimed to understand the role of the acetabular labrum in maintaining a low friction environment in the hip joint. We did this by measuring the resistance to rotation (RTR) of the hip, which reflects the friction of the articular cartilage surface, following focal and complete labrectomy. Five cadaveric hips without evidence of osteoarthritis and impingement were tested. We measured resistance to rotation of the hip joint during 0.5, 1, 2, and 3 times body weight (BW) cyclic loading in the intact hip, and after focal and complete labrectomy. Resistance to rotation, which reflects articular cartilage friction in an intact hip was significantly increased following focal labrectomy at 1-3 BW loading, and following complete labrectomy at all load levels. The acetabular labrum appears to maintain a low friction environment, possibly by sealing the joint from fluid exudation. Even focal labrectomy may result in increased joint friction, a condition that may be detrimental to articular cartilage and lead to osteoarthritis. PMID:22176711

  14. Postural correction reduces hip pain in adult with acetabular dysplasia: a case report

    PubMed Central

    Lewis, Cara L.; Khuu, Anne; Marinko, Lee

    2015-01-01

    Developmental dysplasia of the hip is often diagnosed in infancy, but less severe cases of acetabular dysplasia are being detected in young active adults. The purpose of this case report is to present a non-surgical intervention for a 31-year-old female with mild acetabular dysplasia and an anterior acetabular labral tear. The patient presented with right anterior hip and groin pain, and she stood with the trunk swayed posterior to the pelvis (swayback posture). The hip pain was reproduced with the anterior impingement test. During gait, the patient maintained the swayback posture and reported 6/10 hip pain. Following correction of the patient’s posture, the patient’s pain rating was reduced to a 2/10 while walking. The patient was instructed to maintain the improved posture. At the 1 year follow-up, she demonstrated significantly improved posture in standing and walking. She had returned to recreational running and was generally pain-free. The patient demonstrated improvement on self-reported questionnaires for pain, function and activity. These findings suggest that alteration of posture can have an immediate and lasting effect on hip pain in persons with structural abnormality and labral pathology. PMID:25731688

  15. Damage evolution in acetabular replacements under long-term physiological loading conditions.

    PubMed

    Wang, J-Y; Heaton-Adegbile, P; New, A; Hussell, J G; Tong, J

    2009-05-29

    Damage development in cemented acetabular replacements has been studied in bovine pelvic bones under long-term physiological loading conditions, including normal walking, stair climbing and a combined block loading with representative routine activities. The physiological loading conditions were achieved using a specially designed hip simulator for fixation endurance testing. Damage was detected and monitored using micro-CT scanning at regular intervals of the experiments, and verified by microscopic studies post testing. The results show that debonding at the bone-cement interface defined the failure of cement fixation in all cases, and debondings initiated near the dome of the acetabulum in the superior-posterior quadrant, consistent with the high-stress region identified from the finite element analysis of implanted acetabular models Zant, N.P., Heaton-Adegbile, P., Hussell, J.G., Tong, J., 2008b. In-vitro fatigue failure of cemented acetabular replacements-a hip simulator study. Journal of Biomechanical Engineering, Transactions of the ASME, 130, 021019-1-9]; [Tong, J., Zant, N.P., Wang, J-Y., Heaton-Adegbile, P., Hussell, J.G., 2008. Fatigue in cemented acetabulum. International Journal of Fatigue, 30(8), 1366-1375]. PMID:19345357

  16. The Morscher Press Fit acetabular component: a nine- to 13-year review.

    PubMed

    Gwynne-Jones, D P; Garneti, N; Wainwright, C; Matheson, J A; King, R

    2009-07-01

    We reviewed the results at nine to 13 years of 125 total hip replacements in 113 patients using the monoblock uncemented Morscher press-fit acetabular component. The mean age at the time of operation was 56.9 years (36 to 74). The mean clinical follow-up was 11 years (9.7 to 13.5) and the mean radiological follow-up was 9.4 years (7.7 to 13.1). Three hips were revised, one immediately for instability, one for excessive wear and one for deep infection. No revisions were required for aseptic loosening. A total of eight hips (7.0%) had osteolytic lesions greater than 1 cm, in four around the acetabular component (3.5%). One required bone grafting behind a well-fixed implant. The mean wear rate was 0.11 mm/year (0.06 to 0.78) and was significantly higher in components with a steeper abduction angle. Kaplan-Meier survival curves at 13 years showed survival of 96.8% (95% confidence interval 90.2 to 99.0) for revision for any cause and of 95.7% (95% confidence interval 88.6 to 98.4) for any acetabular re-operation. PMID:19567847

  17. ANALYSIS OF THE SEGMENTAL IMPACTION OF FEMORAL HEAD FOLLOWING AN ACETABULAR FRACTURE SURGICALLY MANAGED

    PubMed Central

    Guimarães, Rodrigo Pereira; Kaleka, Camila Cohen; Cohen, Carina; Daniachi, Daniel; Keiske Ono, Nelson; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Riccioli, Walter

    2015-01-01

    Objective: Correlate the postoperative radiographic evaluation with variables accompanying acetabular fractures in order to determine the predictive factors for segmental impaction of femoral head. Methods: Retrospective analysis of medial files of patients submitted to open reduction surgery with internal acetabular fixation. Within approximately 35 years, 596 patients were treated for acetabular fractures; 267 were followed up for at least two years. The others were excluded either because their follow up was shorter than the minimum time, or as a result of the lack of sufficient data reported on files, or because they had been submitted to non-surgical treatment. The patients were followed up by one of three surgeons of the group using the Merle d'Aubigné and Postel clinical scales as well as radiological studies. Results: Only tow studied variables-age and amount of postoperative reductionshowed statistically significant correlation with femoral head impaction. Conclusions: The quality of reduction-anatomical or with up to 2mm residual deviation-presents a good radiographic evolution, reducing the potential for segmental impaction of the femoral head, a statistically significant finding. PMID:27004191

  18. Temporary Balloon Occlusion of the Abdominal Aorta in Treatment of Complex Acetabular Fracture

    PubMed Central

    Hao, Zhenhai; Zhou, Dongsheng; Wang, Fu; Li, Lianxin; He, Jiliang

    2016-01-01

    Background The aim of this study was to explore the efficacy of temporary balloon occlusion of the abdominal aorta assisting open reduction and internal fixation (ORIF) in the treatment of complex acetabular fracture. Material/Methods From August 2000 to October 2011, a total of 48 patients with complex acetabular fracture were enrolled in this study. Average operative time, intraoperative blood loss volume, blood transfusion volume, satisfactory reduction, and postoperative functional recovery rate were recorded and compared between the 2 groups. Results A significant difference was observed between the 2 groups in operative time (P=0.003). For intraoperative blood loss and blood transfusion, ORIF combined with temporary balloon occlusion of abdominal aorta techniques appeared to be superior to normal ORIF (blood loss: P=0.007; and blood transfusion: P=0.019, respectively). However, no differences were observed in postoperative blood loss or transfusion (P>0.05). Patients in group A showed better hip function than those in group B (group A: a good-to-excellent rate of 77.8%; group B: a good-to-excellent rate of 78.3%; P>0.05). With regard to the incidence of postoperative complications, there were no significant differences between the 2 groups (group A: 9/18; group B: 11/23; P=0.890). Conclusions In the treatment of complex acetabular fracture, temporary balloon occlusion of the abdominal aorta is a reliable technique to assist ORIF surgery to staunch the flow of blood. PMID:27367975

  19. Histology of damaged acetabular cartilage in symptomatic femoroacetabular impingement: an observational analysis.

    PubMed

    Kohl, Sandro; Hosalkar, Harish S; Mainil-Varlet, P; Krueger, Andreas; Buechler, Lorenz; Siebenrock, Klaus

    2011-01-01

    This prospective study on symptomatic adult patients with femoroacetabular impingement (FAI) who underwent open surgical intervention for management was designed to identify any obvious histological differences in the damaged acetabular cartilage within different subgroups of FAI. 20 patients underwent surgical intervention following safe surgical dislocation of the hip. There were 6 cases of cam impingement, 5 cases of pincer impingement and 9 of the mixed type. Pincer impingement cases demonstrated a characteristic focal, well-circumscribed and localized area of severe damage. On the other hand, cases with cam impingement showed a diffuse area of involvement affecting a larger surface of the acetabular cartilage, with degenerative changes, superficial erosions and some discontinuities. A small biopsy specimen of the acetabular rim including bone, cartilage and labrum from the affected zone was obtained in all cases. Histological evaluation was performed under normal and polarized light microscopy. Histological findings helped corroborate the pre-operative diagnosis and also define the unique nature of impingement and specific damage according to the type of impingement. PMID:21484743

  20. A Comparison of the Contact Force Distributions on the Acetabular Surface Due to Orthopedic Treatments for Developmental Hip Dysplasia.

    PubMed

    Márquez-Flórez, Kalenia M; Silva, Octavio; Narváez-Tovar, Carlos A; Garzón-Alvarado, Diego A

    2016-07-01

    We used a three-dimensional rigid body spring model (RBSM) to compare the contact force distributions on the acetabular surface of the infant hip joint that are produced by three orthopedic treatments for developmental dysplasia of the hip (DDH). We analyzed treatments using a Pavlik harness, a generic rigid splint, and a spica cast. The joint geometry was modeled from tomography images of a 1-year-old female. The articular cartilage was modeled as linear springs connecting the surfaces of the acetabulum and the femoral head, whereas the femur and the hip bone were considered as rigid bodies. The hip muscles were modeled as tensile-only preloaded springs. The treatments with the Pavlik harness and the generic rigid splint were modeled for an infant in supine position with a hip flexion angle of 90 deg. Also, since rigid splints are often recommended when children are initiating their gait phase, we modeled the treatment with the infant in standing position. For the spica cast, we only considered the infant in standing position with a flexion angle of 0 deg, and the fixation bar at two heights: at the ankle and at the knee. In order to analyze the effect of the hip abduction angle over the contact force distribution, different abduction angles were used for all the treatments modeled. We have found that the treatments with the infant in supine position, with a flexion angle of 90 deg and abduction angles between 60 deg and 80 deg, produce a more homogenous contact force distribution compared to those obtained for the treatments with the infant in standing position. PMID:27150210

  1. New is the well-forgotten old: The use of dry cupping in musculoskeletal medicine.

    PubMed

    Rozenfeld, Evgeni; Kalichman, Leonid

    2016-01-01

    Cupping is an ancient technique used in treating pain and various disorders. Different techniques have been developed over time, however, applying a cup to create suction over a painful area, is common to all. Dry or fire cupping, used on the intact skin, leaves bluish circular hematomas. Recently, interest in cupping has re-emerged and subsequently, several studies have begun to investigate the mechanisms of cupping therapy. Mechanically, cupping increases blood circulation, whereas physiologically it activates the immune system and stimulates the mechanosensitive fibers, thus leading to a reduction in pain. There is initial scientific evidence that dry cupping is able to reduce musculoskeletal pain. Since cupping is an inexpensive, noninvasive and low-risk (if performed by a trained practitioner) therapeutic modality, we believe that it should be included in the arsenal of musculoskeletal medicine. It is essential to perform additional studies clarifying the biological mechanism and clinical effects of cupping. PMID:26891653

  2. Dielectric elastomer actuators for octopus inspired suction cups.

    PubMed

    Follador, M; Tramacere, F; Mazzolai, B

    2014-01-01

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms. PMID:25253019

  3. Octopus-like suction cups: from natural to artificial solutions.

    PubMed

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-06-01

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance. PMID:25970079

  4. OPERATIVE TREATMENT OF TRANSVERSE ACETABULAR FRACTURES: IS IT REALLY NECESSARY TO FIX BOTH COLUMNS?

    PubMed Central

    Giordano, Vincenzo; do Amaral, Ney Pecegueiro; Pallottino, Alexandre; Albuquerque, Rodrigo Pires e; Franklin, Carlos Eduardo; Labronici, Pedro José

    2009-01-01

    Objective: we prospectively evaluated clinical and radiographic outcomes in patients with displaced combined transverse-posterior wall acetabular fractures managed at our Institution over a period of seven years by posterolateral single approach, direct posterior wall and posterior column reduction and plating, and indirect reduction of anterior column controlled by fluoroscopic images with or without lag-screw fixation. The aim was to identify if the obtained immediate postoperative Matta radiographic roof-arc angles after fracture reduction and fixation alters in the postoperative period when comparing posterior plating alone versus posterior plate and anterior column lag-screw fixation. Patients and Methods: 35 skeletally mature patients (31 male and four female, with mean age of 39.9 years old [range, 23.3 to 66.7 y/o]) with combined transverse-posterior wall acetabular fractures surgically treated by a posterolateral single approach were enrolled in this prospective investigation. Nineteen patients had associated orthopaedic injuries. The first part of the acetabular fracture management was similar to all patients and consisted in anatomical reduction and fixation of the transverse posterior component followed by anatomical reduction and fixation of the posterior wall component. The transverse anterior component reduction was controlled by fluoroscopic images (anteroposterior (AP), iliac oblique, and obturator oblique views) and digital palpation through the greater sciatic notch. Fifteen of the 35 patients had an additional lag-screw fixation from the posterior to the anterior columns with an extra-long small-fragment cortical screw. AP and Judet oblique radiographic views were taken at the end of the procedure and roof-arc angles were measured. Clinical results were assigned according to the grading system of Merle D'Aubigne´ and Postel as modified by Matta et al. Radiographic roof-arc angles were checked and compared between the two groups of patients to

  5. The response function of modulated grid Faraday cup plasma instruments

    NASA Technical Reports Server (NTRS)

    Barnett, A.; Olbert, S.

    1986-01-01

    Modulated grid Faraday cup plasma analyzers are a very useful tool for making in situ measurements of space plasmas. One of their great attributes is that their simplicity permits their angular response function to be calculated theoretically. An expression is derived for this response function by computing the trajectories of the charged particles inside the cup. The Voyager Plasma Science (PLS) experiment is used as a specific example. Two approximations to the rigorous response function useful for data analysis are discussed. The theoretical formulas were tested by multi-sensor analysis of solar wind data. The tests indicate that the formulas represent the true cup response function for all angles of incidence with a maximum error of only a few percent.

  6. Earliest Directly-Dated Human Skull-Cups

    PubMed Central

    Bello, Silvia M.; Parfitt, Simon A.; Stringer, Chris B.

    2011-01-01

    Background The use of human braincases as drinking cups and containers has extensive historic and ethnographic documentation, but archaeological examples are extremely rare. In the Upper Palaeolithic of western Europe, cut-marked and broken human bones are widespread in the Magdalenian (∼15 to 12,000 years BP) and skull-cup preparation is an element of this tradition. Principal Findings Here we describe the post-mortem processing of human heads at the Upper Palaeolithic site of Gough's Cave (Somerset, England) and identify a range of modifications associated with the production of skull-cups. New analyses of human remains from Gough's Cave demonstrate the skilled post-mortem manipulation of human bodies. Results of the research suggest the processing of cadavers for the consumption of body tissues (bone marrow), accompanied by meticulous shaping of cranial vaults. The distribution of cut-marks and percussion features indicates that the skulls were scrupulously 'cleaned' of any soft tissues, and subsequently modified by controlled removal of the facial region and breakage of the cranial base along a sub-horizontal plane. The vaults were also ‘retouched’, possibly to make the broken edges more regular. This manipulation suggests the shaping of skulls to produce skull-cups. Conclusions Three skull-cups have been identified amongst the human bones from Gough's Cave. New ultrafiltered radiocarbon determinations provide direct dates of about 14,700 cal BP, making these the oldest directly dated skull-cups and the only examples known from the British Isles. PMID:21359211

  7. Cohesive suction-cup force in cell separation dynamics

    NASA Astrophysics Data System (ADS)

    Vasseur, H.

    2010-07-01

    When an external pulling force is applied onto a cell stuck to its substrate, a reacting "suction-cup" force, due to the slow penetration of the surrounding fluid between the cell and the substrate, opposes to the separation. It can overcome other known adhesive forces when the process is sufficiently violent (typically 105 N/m2). The physical origin of this effect may be compared with that leaning a suction-cup against a bathroom wall. We address the consequences of this effect on i) the separation energy, ii) the fluid motion surrounding the cell, and iii) the inhibition of cell motion.

  8. Exposure of the superior gluteal neurovascular bundle for the safe application of acetabular reinforcement cages in complex revisions.

    PubMed

    Smitham, Peter J; Kosuge, Dennis; Howie, Donald W; Solomon, Lucian B

    2016-05-16

    The posterior approach to the hip is the most common extensile approach used, however exposure is limited superiorly by the superior gluteal neurovascular bundle (SGNB). The extra-pelvic course of the SGNB demonstrates variability between individuals, occasionally located only 1 cm from the acetabular rim. In complex acetabular reconstructions where the application of a reinforcement cage maybe required protecting the SGNB is challenging. The flanges of these cages are designed to sit on the ilium superior to the acetabular rim and to receive screws for fixation. The application of such cages may result in iatrogenic injury to the SGNB by way of forceful retraction or entrapment. We describe a technique that involves exposure and release of the SGNB such that the flanges of cage constructs may be safely applied. PMID:27079287

  9. Survival of ceramic bearings in total hip replacement after high-energy trauma and periprosthetic acetabular fracture.

    PubMed

    Salih, S; Currall, V A; Ward, A J; Chesser, T J S

    2009-11-01

    Surgeons remain concerned that ceramic hip prostheses may fail catastrophically if either the head or the liner is fractured. We report two patients, each with a ceramic-on-ceramic total hip replacement who sustained high-energy trauma sufficient to cause a displaced periprosthetic acetabular fracture in whom the ceramic bearings survived intact. Simultaneous fixation of the acetabular fracture, revision of the cementless acetabular prosthesis and exchange of the ceramic bearings were performed successfully in both patients. Improved methods of manufacture of new types of alumina ceramic with a smaller grain size, and lower porosity, have produced much stronger bearings. Whether patients should be advised to restrict high-impact activities in order to protect these modern ceramic bearings from fracture remains controversial. PMID:19880903

  10. Optimal acetabular component orientation estimated using edge-loading and impingement risk in patients with metal-on-metal hip resurfacing arthroplasty.

    PubMed

    Mellon, Stephen J; Grammatopoulos, George; Andersen, Michael S; Pandit, Hemant G; Gill, Harinderjit S; Murray, David W

    2015-01-21

    Edge-loading in patients with metal-on-metal resurfaced hips can cause high serum metal ion levels, the development of soft-tissue reactions local to the joint called pseudotumours and ultimately, failure of the implant. Primary edge-loading is where contact between the femoral and acetabular components occurs at the edge/rim of the acetabular component whereas impingement of the femoral neck on the acetabular component's edge causes secondary or contrecoup edge-loading. Although the relationship between the orientation of the acetabular component and primary edge-loading has been identified, the contribution of acetabular component orientation to impingement and secondary edge-loading is less clear. Our aim was to estimate the optimal acetabular component orientation for 16 metal-on-metal hip resurfacing arthroplasty (MoMHRA) subjects with known serum metal ion levels. Data from motion analysis, subject-specific musculoskeletal modelling and Computed Tomography (CT) measurements were used to calculate the dynamic contact patch to rim (CPR) distance and impingement risk for 3416 different acetabular component orientations during gait, sit-to-stand, stair descent and static standing. For each subject, safe zones free from impingement and edge-loading (CPR <10%) were defined and, consequently, an optimal acetabular component orientation was determined (mean inclination 39.7° (SD 6.6°) mean anteversion 14.9° (SD 9.0°)). The results of this study suggest that the optimal acetabular component orientation can be determined from a patient's motion and anatomy. However, 'safe' zones of acetabular component orientation associated with reduced risk of dislocation and pseudotumour are also associated with a reduced risk of edge-loading and impingement. PMID:25482661

  11. Morphometric assessment of the canine hip joint using the dorsal acetabular rim view and the centre-edge angle.

    PubMed

    Meomartino, L; Fatone, G; Potena, A; Brunetti, A

    2002-01-01

    The dorsal acetabular rim (DAR) view of the hip joint can be used to assess the weightbearing portion of the acetabulum and the acetabular coverage, providing an adjunct to the conventional ventrodorsal (VD) view in the radiographic evaluation of hip dysplasia in the dog. A quantitative index of acetabular coverage in the DAR view, the acetabular slope (AS) angle, was originally proposed in 1990. The aim of the present study was to make a prospective, comparative assessment of a new parameter, the centre-edge (CE) angle, with the AS angle, for the evaluation of the acetabular coverage of the femoral head in the DAR view. The reliability and repeatability of the two parameters was assessed using the r(I) value of intraclass correlation coefficient (ICC) in a prospective study of 208 hip joints in large and giant breed dogs. An estimation of the added value of using the DAR view, compared with that of the VD standard view alone, was also assessed. The CE angle showed a higher r(I) value compared with the AS angle; in 26 per cent of hips of FCI classes A, B and C, the DAR view provided additional diagnostic information compared with the VD view, with respect to lateralisation and/or initial changes to the dorsal rim. It is concluded that the CE angle is more reliable than the AS angle in the evaluation of acetabular coverage, and that the DAR view provides valuable data compared with the VD view alone in the early stages of canine hip dysplasia. PMID:11833819

  12. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    PubMed

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. PMID:25725589

  13. Analysis of spinal alignment and pelvic parameters on upright radiographs: implications for acetabular development

    PubMed Central

    Pytiak, Andrew; Bomar, James D.; Peterson, Jonathan B.; Schmitz, Matthew R.; Pennock, Andrew T.; Wenger, Dennis R.; Upasani, Vidyadhar V.

    2016-01-01

    The purpose of this study was to correlate measures of sagittal spinopelvic alignment [lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT) and pelvic incidence (PI)] and measures of acetabular coverage [lateral center edge angle (LCEA) and Tonnis angle] in asymptomatic adolescents on standing biplanar radiographs. We hypothesized that subjects with increased pelvic incidence and LL would have increased anterior PT and increased measures of acetabular coverage. Upright anteroposterior and lateral spinopelvic radiographs were obtained using EOS imaging technique. LCEA and Tonnis angle were calculated on the anteroposterior images and the lateral images were analyzed for LL, PI, PT and SS. LL was found to have a strong correlation with SS (rs = 0.786, P  <  0.001), moderate correlation with PI (rs  =  0.529, P  <  0.001), and a poor inverse correlation with PT (rs  = −0.167, P  =  0.018). However, LCEA was not found to be significantly correlated with PT (rs  =  0.084, P  =  0.238) and Tonnis angle was not found to be correlated with any of the sagittal spinopelvic measures. Healthy, asymptomatic adolescents with increased pelvic incidence and lumbar lordosis did not have increased anterior PT or increased measures of acetabular coverage. The correlations identified in previous cadaveric studies or clinical studies evaluating changes between supine and standing radiographs are not supported in this healthy adolescent population. Our findings may suggest that an individual’s acetabulum develops as a dynamic adaptation to one's particular sagittal spinopelvic alignment to optimize femoral head coverage. Level III. Diagnostic – Investigating a diagnostic test. PMID:27583160

  14. Inguinal Abnormalities in Male Patients with Acetabular Fractures Treated Using an Ilioinguinal Exposure

    PubMed Central

    Firoozabadi, Reza; Stafford, Paul; Routt, Milton

    2015-01-01

    Background: Surgeons performing an ilioinguinal exposure for acetabular fracture surgery need to be aware of aberrant findings such as inguinal hernias and spermatic cord lesions. The purpose of this study is to report these occurrences in a clinical series of adult males undergoing acetabular fracture fixation and a series of adult male cadavers. The secondary aim is to characterize these abnormalities to aid surgeons in detecting these abnormalities preoperatively and coordinating a surgical plan with a general surgeon. Methods: Clinical study- Retrospective review of treated acetabular fractures through an ilioinguinal approach. Incidence of inguinal canal and spermatic cord abnormalities requiring general surgery consultation were identified. Corresponding CT scans were reviewed and radiographic characteristics of the spermatic cord abnormalities and/or hernias were noted. Cadaveric study- 18 male cadavers dissected bilaterally using an ilioinguinal exposure. The inguinal canal and the contents of the spermatic cord were identified and characterized. Results: Clinical Study- 5.7% (5/87) of patients had spermatic cord lesion and/or inguinal hernia requiring general surgical intervention. Preoperative pelvic CT scan review identified abnormalities noted intraoperatively in four of the five patients. Cord lipomas visualized as enlargements of the spermatic cord with homogeneous density. Hernias visualized as enlarged spermatic cords with heterogeneous density. Cadaver Study- 31% (11/36) of cadavers studied had spermatic cord and/or inguinal canal abnormalities. Average cord diameter in those with abnormalities was 24.9 mm (15-28) compared to 16 mm (11-22) in normal cords, which was statistically significant. Discussion: The clinical and cadaveric findings emphasize the importance of understanding inguinal abnormalities and the value of detecting them preoperatively. The preoperative pelvic CT scans were highly sensitive in detecting inguinal abnormalities. PMID

  15. Effect of methotrexate exposure at middle gestation on the inner plate of the ocular cup and lens in the rat fetus

    PubMed Central

    Zu, Cheng Zhe; Kuroki, Masato; Hirako, Ayano; Takeuchi, Takashi; Furukawa, Satoshi; Sugiyama, Akihiko

    2016-01-01

    Pregnant rats were treated intraperitoneally with a single dose of methotrexate (MTX) 90 mg/kg on gestation day (GD) 13, and fetal eyeballs were examined time-dependently from GD 13.5 to 15.5. Throughout the experimental period, the inner plate of the ocular cup in the MTX group was significantly thinner than that in the control group. In the inner plate of the ocular cup on GD 15 and 15.5, whereas a developed ganglion cell layer was observed in the control group, the ganglion cell layer in the MTX group was undeveloped and indistinguishable. Disturbance of the arrangement of lens fiber cells, narrowing of the hyaloid cavity of the optic cup, and hypoplasia of optic nerve fibers were observed in the MTX group on GD 15 and 15.5. Increase of pyknosis and decrease of mitosis were induced in the optic cup and the lens epithelium of the MTX group. In the inner plate of the optic cup and the lens epithelium of the MTX group, the cleaved caspase-3- and TUNEL-positive rates increased significantly throughout the experimental period. The phospho-histone H3-positive rate in the inner plate of the optic cup decreased significantly from GD 13.5 to 14.5, and it recovered on GD 15. On the other hand, the phospho-histone H3-positive rate in the lens epithelium decreased significantly throughout the experimental period. These results suggested that optic tissue on GD 13 in rats was sensitive to MTX. PMID:27559242

  16. All-Arthroscopic Reconstruction of the Acetabular Labrum by Capsular Augmentation

    PubMed Central

    Nwachukwu, Benedict U.; Alpaugh, Kyle; McCormick, Frank; Martin, Scott D.

    2015-01-01

    The acetabular labrum plays an important role in hip joint stability and articular cartilage maintenance. As such, reconstitution of the labral complex is ideal. In cases in which the labrum is too degenerative to allow adequate reconstruction with current repair techniques, a capsular augmentation is a novel technique that can be used to restore the labral structure. Use of capsular augmentation enables preservation of the donor-tissue blood supply with local tissue transfer, without adding significant complexity to the procedure or significant donor-site morbidity. PMID:26052488

  17. Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study.

    PubMed

    Ghosh, Rajesh

    2016-09-01

    The aim of the study is to determine failure of the cemented polyethylene acetabular component, which might occur due to excessive bone resorption, cement-bone interface debonding and fatigue failure of the cement mantle. Three-dimensional finite element models of intact and implanted pelvic bone were developed and bone remodeling algorithm was implemented for present analysis. Soderberg fatigue failure diagram was used for fatigue assessment of the cement mantle. Hoffman failure criterion was considered for prediction of cement-bone interface debonding. Results indicate fatigue failure of the cement mantle and implant-bone interface debonding might not occur due to bone remodeling. PMID:27408485

  18. Plastic Straining of Iridium Alloy DOP-26 During Cup Sizing Operations

    SciTech Connect

    Ohriner, Evan Keith; Ulrich, George B; Sabau, Adrian S

    2007-09-01

    DOP-26 iridium alloy cups are used for fuel cladding for radioisotope power systems. The cups are deep drawn and recrystallized prior to final fabrication operations. This study characterizes the plastic deformation of cups during a sizing operation following the recrystallization heat treatment. The purpose of the sizing operation is to achieve the specified roundness, diameter, and radius dimensions of the cup. The operation introduces various levels of plastic strain in the cup. Plastic strain can be a cause of inhomogeneous or abnormal grain growth during subsequent exposure to elevated temperature during the service life of the fueled clad. This is particularly true in the case of cups which have irregularities in the cup walls from the deep drawing operations. Diameter and roundness measurements were made on two cups both before and after sizing. Plastic strain levels were calculated using the ABAQUSTM finite element software. The calculated plastic strain levels in both cups were below 0.025, a value shown to be below the critical strain for abnormal grain growth during a simulated service exposure. The calculated maximum plastic strain was found to increase with increased applied sizing load and was not sensitive to the input value for the clearance between the cup and the sizing die. The calculated geometry of the sized cups was in good agreement with the measurements on the finished cups.

  19. Cup Stacking: Does It Deserve a Place in Physical Education Curricula?

    ERIC Educational Resources Information Center

    Udermann, Brian E.; Murray, Steven R.

    2006-01-01

    Cup stacking has become commonplace in today's physical education nomenclature. Proponents make claims that cup stacking improves cognitive, affective, and psychomotor abilities. At physical education conferences, scores of professional physical educators eagerly watch cup stacking representatives construct and deconstruct a variety of pyramids…

  20. 77 FR 20846 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items and Packaging Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-06

    ... COMMISSION Certain Food Containers, Cups, Plates, Cutlery, and Related Items and Packaging Thereof... importation of certain food containers, cups, plates, cutlery, and related items and packaging thereof by... importation of certain food containers, cups, plates, cutlery, and related items and packaging thereof...

  1. 76 FR 53051 - Safety Zone; ISAF Nations Cup Grand Final Fireworks Display, Sheboygan, WI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-25

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; ISAF Nations Cup Grand Final Fireworks... public interest. Background and Purpose The ISAF Nations Cup Grand Final fireworks are a City permitted.... 165.T09-0755 Safety Zone; ISAF Nations Cup Grand Final Fireworks Display, Sheboygan, Wisconsin....

  2. 77 FR 4501 - Special Local Regulation and Safety Zone; America's Cup Sailing Events, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ...The Coast Guard proposes to adopt a temporary special local regulation and temporary safety zone for those portions of the ``America's Cup World Series,'' the ``Louis Vuitton Cup'' challenger selection series, and the ``America's Cup Finals Match'' sailing regattas that may be conducted in the waters of San Francisco Bay adjacent to the City of San Francisco waterfront in the vicinity of the......

  3. Infant Nutrition: Drinking from a Cup, Eating from a Spoon.

    ERIC Educational Resources Information Center

    Texas Child Care, 1994

    1994-01-01

    Discusses the developmental stages of infants' and children's eating habits. Provides directions for introducing cup and spoon to babies and for making homemade infant foods. Includes information on breast feeding and how child caregivers can support breast-feeding mothers. (HTH)

  4. Microindentation hardness evaluation of iridium alloy clad vent set cups

    NASA Astrophysics Data System (ADS)

    Ulrich, George B.; DeRoos, Larry F.; Stinnette, Samuel E.

    1993-01-01

    An iridium alloy, DOP-26, is used as cladding for 238PuO2 fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  5. Microindentation hardness evaluation of iridium alloy clad vent set cups

    SciTech Connect

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1992-05-15

    An iridium alloy, DOP-26, is used as cladding for {sup 238}PuO{sup 2} fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration`s Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  6. Microindentation hardness evaluation of iridium alloy clad vent set cups

    SciTech Connect

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1992-05-15

    An iridium alloy, DOP-26, is used as cladding for {sup 238}PuO{sup 2} fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  7. Microindentation hardness evaluation of iridium alloy clad vent set cups

    SciTech Connect

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E. )

    1993-01-15

    An iridium alloy, DOP-26, is used as cladding for [sup 238]PuO[sub 2] fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors.

  8. Teaching Transport Phenomena around a Cup of Coffee

    ERIC Educational Resources Information Center

    Condoret, Jean Stephane

    2007-01-01

    The very common situation of waiting for the cooling of a cup of coffee is addressed through a conventional engineering approach, where several important concepts of heat and mass transfer are used. A numerical and analytical solution of the differential equations of the problem are proposed, and assessed by comparing to simple experiments.…

  9. Our Everyday Cup of Coffee: The Chemistry behind Its Magic

    ERIC Educational Resources Information Center

    Petracco, Marino

    2005-01-01

    Coffee consumption has spread worldwide and differences in the raw bean consumption, in roasting conditions and in the extraction procedures used to prepare coffee brews result in a great diversity of chemical composition in the final product, the cup of coffee. Hence, beverage preparation is a fundamental step for enjoying the benefits of this…

  10. NASCAR Winston Cup Race Results for 1975-2003

    ERIC Educational Resources Information Center

    Winner, Larry

    2006-01-01

    Stock car racing has seen tremendous growth in popularity in recent years. We introduce two datasets containing results from all Winston Cup races between 1975 and 2003, inclusive. Students can use any number of statistical methods and applications of basic probability on the data to answer a wide range of practical questions. Instructors and…

  11. The dual mobility cup: what problems does it solve?

    PubMed

    Ko, L Matsen; Hozack, W J

    2016-01-01

    Dual mobility cups have two points of articulation, one between the shell and the polyethylene (external bearing) and one between the polyethylene and the femoral head (internal bearing). Movement occurs at the inner bearing; the outer bearing only moves at extremes of movement. Dislocation after total hip arthroplasty (THA) is a cause of much morbidity and its treatment has significant cost implications. Dual mobility cups provide an increased range of movement and a may reduce the risk of dislocation. This paper reviews the use of these cups in THA, particularly where stability is an issue. Dual mobility cups may be of benefit in primary THA in patients at a high risk of dislocation, such as those who are older with increased comorbidities and a higher American Association of Anesthesiology grade and those with a neuromuscular disease. They may be used at revision surgery where the risk of dislocation is high, such as in patients with many prior dislocations, or those with abductor deficiency. They may also be used in THA for displaced fractures of the femoral neck, which has a notoriously high rate of dislocation. PMID:26733643

  12. Technology. The Hot Cup Caper. Probing for Scientific Knowledge.

    ERIC Educational Resources Information Center

    Ramondetta, June

    1994-01-01

    Students can explore temperature and heat conductivity by examining materials that make good cups for hot cocoa. Using temperature probes from computer-based science packages, students can measure gradual change in the liquid's temperature, watch as data are plotted on the computer, and explain why they chose a specific material. (SM)

  13. Leidos Reclaims Defelice Cup at Annual Golf Tournament | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer Leidos Biomedical Research reclaimed the Defelice Cup trophy from NCI at the eighth annual Ronald H. Defelice golf tournament, held October 14. The final score was 15–7, with Leidos Biomed tying the series 4 to 4. Fourteen players on each team battled it out at Rattlewood golf course in Mount Airy, Md.

  14. A confirmed case of toxic shock syndrome associated with the use of a menstrual cup.

    PubMed

    Mitchell, Michael A; Bisch, Steve; Arntfield, Shannon; Hosseini-Moghaddam, Seyed M

    2015-01-01

    Menstrual cups have been reported to be an acceptable substitute for tampons. These flexible cups have also been reported to provide a sustainable solution to menstrual management, with modest cost savings and no significant health risk. The present article documents the first case of toxic shock syndrome associated with the use of a menstrual cup in a woman 37 years of age, using a menstrual cup for the first time. Toxic shock syndrome and the literature on menstrual cups is reviewed and a possible mechanism for the development of toxic shock syndrome in the patient is described. PMID:26361491

  15. Contact stress analysis with application to drawn cup roller bearing with aluminum housing

    SciTech Connect

    Chiu, Y.P.

    1986-01-01

    This paper describes the methodology and some computer-aided procedures for analyzing the contact of roller and a drawn cup bearing ring inside a housing material of low tensile strength. The analysis can be used to predict the onset of plastic yielding in the housing. It also discusses the role of stresses arising from the press fit between the cup and the housing in preventing the relative slippage at the cup/housing interface and fretting corrosion. Illustrative examples are shown for a heavy duty drawn cup bearing with aluminum housing for a multitude of loads and cup thicknesses.

  16. Multitechnique characterization of articular surfaces of retrieved ultrahigh molecular weight polyethylene acetabular sockets.

    PubMed

    Magnissalis, E A; Eliades, G; Eliades, T

    1999-01-01

    The articular surfaces of 10 retrieved ultrahigh molecular weight polyethylene acetabular sockets were studied by optical microscopy, X-ray fluorescence spectrometry, multiple internal reflectance FTIR spectroscopy, scanning electron microscopy, and wavelength dispersive X-ray microanalysis. The results revealed characteristic wear patterns including polishing, scratching, pitting, cratering, folding, shredding, burnishing, cracking, embedding of particles, and development of acquired biofilms with various degrees of mineralization. The biofilms formed were mainly of proteinaceous origin, and mineralized regions were composed of calcium phosphates with carbonate impurities. The crystallinity of the polyethylene at the articular surfaces was enhanced compared to the bulk, which was possibly due to the cold work produced in vivo. The mineralized regions were classified into two groups based on the grey levels of the backscattered images obtained. The high-contrast regions that were mainly composed of Ca and P with traces of Al and Si were associated with bone fragments; the low-contrast regions composed of K, Na, Ca, Mg, Si, Al, Fe, Cl, and P were associated with acquired biofilm calcification, which implies the active engagement of biofilms in the long term performance of acetabular sockets in vivo. PMID:10398042

  17. Towards the optimal design of an uncemented acetabular component using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Ghosh, Rajesh; Pratihar, Dilip Kumar; Gupta, Sanjay

    2015-12-01

    Aseptic loosening of the acetabular component (hemispherical socket of the pelvic bone) has been mainly attributed to bone resorption and excessive generation of wear particle debris. The aim of this study was to determine optimal design parameters for the acetabular component that would minimize bone resorption and volumetric wear. Three-dimensional finite element models of intact and implanted pelvises were developed using data from computed tomography scans. A multi-objective optimization problem was formulated and solved using a genetic algorithm. A combination of suitable implant material and corresponding set of optimal thicknesses of the component was obtained from the Pareto-optimal front of solutions. The ultra-high-molecular-weight polyethylene (UHMWPE) component generated considerably greater volumetric wear but lower bone density loss compared to carbon-fibre reinforced polyetheretherketone (CFR-PEEK) and ceramic. CFR-PEEK was located in the range between ceramic and UHMWPE. Although ceramic appeared to be a viable alternative to cobalt-chromium-molybdenum alloy, CFR-PEEK seems to be the most promising alternative material.

  18. New method for determining in vitro structure stiffness of ceramic acetabular liners under different impact conditions.

    PubMed

    Eichhorn, Stefan; Steinhauser, Erwin; Gradinger, Reiner; Burgkart, Rainer

    2012-05-01

    Increasing both patient mobility and prosthesis life span requires improvements in the range of motion and wear behavior of the liner. With the use of new composite alumina-zirconia ceramic materials, the same stability of the liner can be achieved at lower wall thickness than it is possible with alumina-only materials. The aim of this study was developing a method for determining the in vitro structure stiffness of ceramic acetabular liners against impact stresses. The first trials were performed with a common alumina acetabular liner type (Ceramtec; Biolox forte; diameter 28 mm; thickness 7 mm) and a new type of alumina-zirconia (Ceramtec Biolox delta; same dimensions) liner. The clinically established alumina liner was reproducibly damaged using worst case Separation/subluxation equivalent to one-fourth or half of the head diameter, and an impact load of 15 J. The liners containing the new alumina-zirconia material were not damaged in any of the trials up to an impact load of 20 J and half head diameter offset. PMID:22197061

  19. Preliminary analysis on the MD-4® plasma-sprayed titanium acetabular component☆

    PubMed Central

    de Araújo Loures, Elmano; Simoni, Leandro Furtado; Leite, Isabel Cristina Gonçalves; Loures, Daniel Naya; Loures, Clarice Naya

    2015-01-01

    Objectives To evaluate the short-term performance of a type of implant manufactured in Brazil. Methods This study analyzed a cohort of 60 patients who underwent implantation of MD-4® acetabular components during primary hip arthroplasty procedures performed between January 1, 2010, and August 1, 2012. The patients were studied retrospectively with regard to clinical behavior, stability and radiological osseointegration. The patients were followed up for a minimum of 12 months and a maximum of 42 months (mean: 27) and were evaluated by means of the Harris Hip Score, SF-36 questionnaire and serial conventional radiographs. Results All the components were radiologically stable, without evidence of migration or progressive radiolucency lines. On average, the Harris Hip Score evolved from 36.1 to 92.1 (p < 0.001) and the SF-36 showed significant increases in all its domains (p < 0.001). No differences were observed among patients with osteoarthrosis, osteonecrosis, hip dysplasia or other conditions. Conclusions The short-term results showed clinical and radiological signs of stability and osseointegration of the implants, which may represent a predictive factor regarding medium-term survival of this acetabular component. PMID:26229918

  20. Fixation of acetabular fractures via the ilioinguinal versus pararectus approach: a direct comparison.

    PubMed

    Märdian, S; Schaser, K D; Hinz, P; Wittenberg, S; Haas, N P; Schwabe, P

    2015-09-01

    This study compared the quality of reduction and complication rate when using a standard ilioinguinal approach and the new pararectus approach when treating acetabular fractures surgically. All acetabular fractures that underwent fixation using either approach between February 2005 and September 2014 were retrospectively reviewed and the demographics of the patients, the surgical details and complications were recorded. A total of 100 patients (69 men, 31 women; mean age 57 years, 18 to 93) who were consecutively treated were included for analysis. The quality of reduction was assessed using standardised measurement of the gaps and steps in the articular surface on pre- and post-operative CT-scans. There were no significant differences in the demographics of the patients, the surgical details or the complications between the two approaches. A significantly better reduction of the gap, however, was achieved with the pararectus approach (axial: p = 0.025, coronal: p = 0.013, sagittal: p = 0.001). These data suggest that the pararectus approach is at least equal to, or in the case of reduction of the articular gap, superior to the ilioinguinal approach. This approach allows direct buttressing of the dome of the acetabulum and the quadrilateral plate, which is particularly favourable in geriatric fracture patterns. PMID:26330596

  1. Femoroacetabular impingement with chronic acetabular rim fracture - 3D computed tomography, 3D magnetic resonance imaging and arthroscopic correlation

    PubMed Central

    Chhabra, Avneesh; Nordeck, Shaun; Wadhwa, Vibhor; Madhavapeddi, Sai; Robertson, William J

    2015-01-01

    Femoroacetabular impingement is uncommonly associated with a large rim fragment of bone along the superolateral acetabulum. We report an unusual case of femoroacetabular impingement (FAI) with chronic acetabular rim fracture. Radiographic, 3D computed tomography, 3D magnetic resonance imaging and arthroscopy correlation is presented with discussion of relative advantages and disadvantages of various modalities in the context of FAI. PMID:26191497

  2. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  3. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  4. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  5. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  6. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  7. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  8. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  9. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  10. Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years

    PubMed Central

    2012-01-01

    Background and purpose There have been few reports documenting the wear and oxidation performance of the polyethylene bearing surface of HGPI and HGPII THA devices. We evaluated retrieved HGPI and HGPII acetabular liners that had been in situ for more than 10 years and determined whether there was a relationship between clinical and radiographic factors, surface damage, wear, and oxidation. Materials and methods 129 HGPI and II acetabular liners with implantation times of > 10 years were retrieved at 4 institutions between 1997 and 2010. The liners were made from a single resin and were gamma radiation-sterilized in air. Surface damage, linear wear, and oxidation index (OI) were assessed. Differences in clinical and radiographic factors, surface damage, linear wear, and OI for the 2 designs were statistically evaluated separately and together. Results Articular surface damage and backside damage was similar in the 2 designs. The linear penetration rate was 0.14 (SD 0.07) mm/year for the HGPI liners and 0.12 (SD 0.08) mm/year for the HGPII liners. For both cohorts, the rim had a higher OI than the articular surface. 74% of the liners had subsurface cracking and 24% had a complete fracture through the acetabular rim. Interpretation Despite modification of the HGP locking mechanism in the HGPII design, dissociation of the liner from the acetabular shell can still occur if fracture of the rim of the liner develops due to oxidative degradation. PMID:22880709

  11. Clinical research evidence of cupping therapy in China: a systematic literature review

    PubMed Central

    2010-01-01

    Background Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it. This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. Methods We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. Results 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs), 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. Conclusions According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice. PMID:21078197

  12. Tool for cutting locking cups from guide tube mounting screws in a nuclear reactor

    SciTech Connect

    Nee, J.D.; Hahn, J.J.

    1987-09-01

    This patent describes an apparatus for freeing a socket-head screw from a locking cup therefor in a reactor cavity, wherein the locking cup includes a fixed cylindrical side wall encircling the side surface of the screw head and an annular end wall overlying the outer end surface of the screw head. The apparatus consists of: frame means, cylindrical cutter means having a longitudinal axis and having a frustoconical cutting surface with an inner diameter less than the inner diameter of the locking cup side wall and with an outer diameter greater than the outer diameter of the locking cup side wall, and drive means carried by the frame means and coupled to the cutter means for effecting rotation thereof about the axis, the rotating cutter means are operable for severing the locking cup end wall from the locking cup side wall at the junction therebetween when the cutter means is moved against the locking cup substantially coaxially therewith.

  13. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.

    PubMed

    Bellini, Chiara Maria; Galbusera, Fabio; Ceroni, Roberto Giacometti; Raimondi, Manuela Teresa

    2007-03-01

    The primary stability of cementless acetabular components is a prerequisite for their clinical success. The target of the present study was to analyse possible effects of post-operative joint loading on the initial mechanical stability of a press-fitted acetabular prosthesis. For this purpose, a three-dimensional finite element model of the pelvic bone with acetabular reconstruction was set-up. The analysis included two steps: (1) simulation of the prosthesis press-fit implantation and (2) simulation of the instant of peak resultant hip loading during the one-legged stance. The difference between the contact pressures at the bone/implant interface, at the end of the second step and those at the end of the first step was calculated and assumed as an index of variation in mechanical contact due to post-operative weight bearing. The results show that, due to hip loading, contact pressures given by press-fit increase in the postero-superior acetabular region but decrease in the antero-inferior acetabular region. The calculated area in which the contact pressures decrease extend to about 30% of the total contact surface. These results imply that post-operative joint loading significantly reduces the mechanical stability given by press-fit. The decrease in contact pressures at the bone/implant interface may result in a lack of osteointegration, possibly hindering the implant secondary stability. It may also create a route for wear debris, possibly favouring periprosthetic osteolysis, which may lead to further loss in contact and clinical failure of the implant due to loosening. PMID:16569508

  14. The impact of the America's Cup on Fremantle Hospital.

    PubMed Central

    Galvin, G M; Jelinek, G A

    1989-01-01

    The first defence of the America's Cup outside of the USA took place off Fremantle, Western Australia, between October, 1986 and February, 1987. Fremantle Hospital, the nearest hospital to the marinas, was involved in the planning for disasters and for the provision of clinical services to the syndicates involved and the projected crowds of tourists and spectators. The impact of this unique sporting event on the hospital was measured by collecting data from all patients whose presence in Fremantle was related to the yachting. The America's Cup resulted in only 654 attendances and 31 admissions over the 5 months of the event. The figures fell far short of those predicted. A number of conclusions have been drawn. PMID:2610801

  15. Sphere anemometer - a faster alternative solution to cup anemometry

    NASA Astrophysics Data System (ADS)

    Hölling, M.; Schulte, B.; Barth, S.; Peinke, J.

    2007-07-01

    We present an anemometer technique characterized by an instrument in a sealed enclosure without moving parts. Measurements taken with our improved sphere anemometer in comparison to cup anemometer and hot-wire anemometer data subjected to wind gusts are discussed. The hot-wire anemometer serves as a reference with high temporal and spacial resolution. A manually driven "gust generator" produced gusts at low frequencies of about 1Hz. All measurements were carried out in the wind tunnel at the University of Oldenburg.

  16. Oxidative unzipping of stacked nitrogen-doped carbon nanotube cups.

    PubMed

    Dong, Haifeng; Zhao, Yong; Tang, Yifan; Burkert, Seth C; Star, Alexander

    2015-05-27

    We demonstrate a facile synthesis of different nanostructures by oxidative unzipping of stacked nitrogen-doped carbon nanotube cups (NCNCs). Depending on the initial number of stacked-cup segments, this method can yield graphene nanosheets (GNSs) or hybrid nanostructures comprised of graphene nanoribbons partially unzipped from a central nanotube core. Due to the stacked-cup structure of as-synthesized NCNCs, preventing complete exposure of graphitic planes, the unzipping mechanism is hindered, resulting in incomplete unzipping; however, individual, separated NCNCs are completely unzipped, yielding individual nitrogen-doped GNSs. Graphene-based materials have been employed as electrocatalysts for many important chemical reactions, and it has been proposed that increasing the reactive edges results in more efficient electrocatalysis. In this paper, we apply these graphene conjugates as electrocatalysts for the oxygen reduction reaction (ORR) to determine how the increase in reactive edges affects the electrocatalytic activity. This investigation introduces a new method for the improvement of ORR electrocatalysts by using nitrogen dopants more effectively, allowing for enhanced ORR performance with lower overall nitrogen content. Additionally, the GNSs were functionalized with gold nanoparticles (GNPs), resulting in a GNS/GNP hybrid, which shows efficient surface-enhanced Raman scattering and expands the scope of its application in advanced device fabrication and biosensing. PMID:25946723

  17. Development and first experimental tests of Faraday cup array.

    PubMed

    Prokůpek, J; Kaufman, J; Margarone, D; Krůs, M; Velyhan, A; Krása, J; Burris-Mog, T; Busold, S; Deppert, O; Cowan, T E; Korn, G

    2014-01-01

    A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry. This is a unique method for two-dimensional visualisation of ion currents from laser-generated plasmas. A technical description of the new type of Faraday cup is introduced along with an ad hoc data analysis procedure. Experimental results obtained during campaigns at the Petawatt High-Energy Laser for Heavy Ion Experiments (GSI, Darmstadt) and at the Prague Asterix Laser System (AS CR) are presented. Advantages and limitations of the used diagnostic system are discussed. PMID:24517754

  18. Energy balance and dietary habits of America's Cup sailors.

    PubMed

    Bernardi, Elisabetta; Delussu, Sofia A; Quattrini, Filippo M; Rodio, Angelo; Bernardi, Marco

    2007-08-01

    This research, which was conducted with crew members of an America's Cup team, had the following objectives: (a) to assess energy expenditure and intake during training; (b) to evaluate the sailors' diet, and (c) to identify any dietary flaws to determine the appropriate intake of nutrients, correct possible dietary mistakes, and improve their food habits. Energy expenditure was estimated on 15 sailors using direct measurements (oxygen consumption) and a 3-day activity questionnaire. Oxygen consumption was measured on sailors during both on-water America's Cup sailing training and dry-land fitness training. Composition of the diet was estimated using a 3-day food record. Average daily energy expenditure of the sailors ranged from 14.95 to 24.4 MJ, depending on body mass and boat role, with the highest values found in grinders and mastmen. Daily energy intake ranged from 15.7 to 23.3 MJ (from +6% to -18% of energy expenditure). The contributions of carbohydrate, protein, and fat to total energy intake were 43%, 18%, and 39% respectively, values that are not in accord with the recommended guidelines for athletes. Our results show the importance of assessing energy balance and food habits for America's Cup sailors performing different roles. The practical outcome of this study was that the sailors were given dietary advice and prescribed a Mediterranean diet, explained in specific nutrition lectures. PMID:17613739

  19. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation

    PubMed Central

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Kim, Dong-Yeol; Zheng, Long

    2015-01-01

    Background Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. Methods From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. Results There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p < 0.001, respectively). However, there were no significant differences in hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Conclusions Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays

  20. Precooling an acetabular liner makes its insertion into a metal shell easier.

    PubMed

    Kyle, Richard F; Bourgeault, Craig A; Lew, William D; Bechtold, Joan E

    2006-02-01

    Temporary shrinkage of an acetabular polyethylene liner due to precooling could reduce the force required to snap the liner into its metal shell. This study documented cooling and heating rates of liners with a particular locking mechanism design, determined forces required to seat liners in their shells as a function of temperature, and quantified the force surgeons can exert with their thumbs when seating a liner. It took up to 8 minutes to cool 58- and 70-mm liners in an ice-water bath from room temperature to near 0 degrees C, and up to 24 minutes to subsequently warm these liners to near body temperature. Forces required to seat liners were greater at room and body temperatures than at 0 degrees C. Liners precooled to 0 degrees C required insertion forces that could be generated manually by surgeons. PMID:16520215

  1. A Feasibility Study into the Use of Three-Dimensional Printer Modelling in Acetabular Fracture Surgery

    PubMed Central

    Yu, A. W.; Duncan, J. M.; Daurka, J. S.; Lewis, A.; Cobb, J.

    2015-01-01

    There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient's unique anatomy can only lead to improved outcomes. PMID:25709843

  2. Does the ingrowth surface make a difference? A retrieval study of 423 cementless acetabular components.

    PubMed

    Swarts, Eric; Bucher, Thomas A; Phillips, Michael; Yap, Francis H X

    2015-04-01

    The effect of factors such as design, alloy and coating type on bony or fibrous tissue ingrowth was evaluated in a study of 423 retrieved cementless acetabular shells representing 16 shell designs. Small-beaded (250μm) porous coatings, either with or without hydroxyapatite (HA) coatings, proved to be the superior porous surface for bone ingrowth. Small-beaded shells that were Duofix coated had predominantly fibrous tissue ingrowth. In addition to bead size, alloy type and surface type have significant effect on bone ingrowth. In contrast, there is no significant association between bone ingrowth and time in situ, with most bone ingrowth occurring early. Although roughened, press-fit shells have acceptable clinical and Registry data, they showed some of the lowest ingrowth/ongrowth scores of all the shells tested. PMID:25515944

  3. The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases.

    PubMed

    Schmalzried, T P; Wessinger, S J; Hill, G E; Harris, W H

    1994-06-01

    One hundred twenty-two primary total hip arthroplasties were followed for an average of 56 months (range, 48-66 months) in which the Harris-Galante (Zimmer, Warsaw, IN) porous ingrowth acetabular component had been press-fit into the innominate bone without screw fixation. There were no acetabular fractures. No socket was revised for loosening and none were radiographically loose. There was no evidence of disruption of the titanium porous mesh. There was no acetabular osteolysis. Compared to the authors' series of primary hip reconstructions using this same prosthesis inserted with line-to-line reaming and screw fixation, the data indicate that the tight peripheral fit associated with the press-fit technique is effective in reducing both the incidence and extent of bone-implant radiolucencies. However, the increased incidence of radiolucencies near the apex of the acetabulum also suggest that initial contact of the porous surface with live acetabular bone at this location is desirable in order to obtain and maintain an optimal bone-implant interface. Additional studies are necessary to further establish the relationship between the initial fit and long-term fixation of cementless acetabular components. Based on the data and other considerations for eliminating both vascular risk and the potential for fretting wear between the screws and shell, the authors recommend press-fitting without screw fixation for this acetabular component in primary cases when anatomy and bone stock permit. Full seating of the component is recommended in order to obtain dome contact. PMID:8077971

  4. Revision total hip replacement using the cement-in-cement technique for the acetabular component: technique and results for 60 hips.

    PubMed

    Brogan, K; Charity, J; Sheeraz, A; Whitehouse, S L; Timperley, A J; Howell, J R; Hubble, M J W

    2012-11-01

    The technique of femoral cement-in-cement revision is well established, but there are no previous series reporting its use on the acetabular side at the time of revision total hip replacement. We describe the technique and report the outcome of 60 consecutive acetabular cement-in-cement revisions in 59 patients at a mean follow-up of 8.5 years (5 to 12). All had a radiologically and clinically well-fixed acetabular cement mantle at the time of revision. During the follow-up 29 patients died, but no hips were lost to follow-up. The two most common indications for acetabular revision were recurrent dislocation (46, 77%) and to complement femoral revision (12, 20%). Of the 60 hips, there were two cases of aseptic loosening of the acetabular component (3.3%) requiring re-revision. No other hip was clinically or radiologically loose (96.7%) at the latest follow-up. One hip was re-revised for infection, four for recurrent dislocation and one for disarticulation of a constrained component. At five years the Kaplan-Meier survival rate was 100% for aseptic loosening and 92.2% (95% CI 84.8 to 99.6), with revision for any cause as the endpoint. These results support the use of cement-in-cement revision on the acetabular side in appropriate cases. Theoretical advantages include preservation of bone stock, reduced operating time, reduced risk of complications and durable fixation. PMID:23109626

  5. Observations on the initial stability of acetabular components in total hip arthroplasty. An experimental study.

    PubMed

    Pitto, R P; Sterzl, M; Hohmann, D

    1996-01-01

    It was the purpose of the study to investigate the initial stability, with or without screws, of 3 acetabular components with press-fit anchoring, by measuring bone-prosthesis micromovements during the application of physiological loading on the hip simulated in the laboratory. The prostheses, already used clinically, were characterized by different shapes and coatings. For the purposes of the study a total of 30 acetabula were used in 10 human pelves in polyurethane and 5 human pelves preserved at -20 degrees. The pelves were assembled on a hydraulic bench test with a steel jig that could be oriented, and they were cemented with polymethylmethacrylate. Three electromagnetic transducers with sensitivity of up to 1 micron (+ 500 microns) were used to measure the micromovements between the prosthesis and the acetabular rim in its three anatomical quadrants. Bone-prosthesis micromovements were recorded during 5 consecutive load tests, from 0 to 2.39 kN (244 kg). Experimental studies have shown that bone-prosthesis micromovement that exceeds 150 microns obstructs bone integration. The most significant micromovement was observed for all of the prostheses, without accessory screws, in the iliac quadrant, but only the hemispherical one with a semi-smooth surface in zirconium oxide surpassed the threshold of 150 microns. Prostheses with a porous surface demonstrated good stability (102 +/- 33 microns and 94 +/- 36 microns, respectively). None of the prostheses demonstrated micromovement exceeding 90 microns in the area corresponding to the pubis and the ischium. The use of 2 accessory screws sensitively increased the stability of all of the prostheses on the ilium, reducing the average micromovement by 40 microns. Reduction of micromovement was less on the pubis and on the ischium. PMID:8968114

  6. Measurement of lateral acetabular coverage: a comparison between CT and plain radiography

    PubMed Central

    Chadayammuri, Vivek; Garabekyan, Tigran; Jesse, Mary-Kristen; Pascual-Garrido, Cecilia; Strickland, Colin; Milligan, Kenneth; Mei-Dan, Omer

    2015-01-01

    We prospectively evaluated the degree of absolute agreement between measurements of lateral center-edge angle (LCEA) on plain radiography (XR) and computed tomography (CT) in a consecutive cohort of 205 patients (410 hips) undergoing hip arthroscopy. Preoperative measurements of the LCEA were performed bilaterally utilizing standardized anteroposterior radiographs and coronal reformatted CT scans. Demographic variables including age, gender, height, weight, BMI and clinical diagnosis were recorded for all patients. Overall, measured values of the LCEA were 2.1° larger on CT compared with XR (32.9° versus 30.8°, P < 0.001). Subgroup analysis revealed the highest mean difference in hips with acetabular dysplasia and concomitant cam-type femoroacetabular impingement (FAI) [mean difference (CT–XR) 5.5°, 95% confidence interval (CI) 3.7°–7.3°, P = 0.011], followed by hips with isolated acetabular dysplasia (mean difference [CT–XR] 4.9°, 95% CI 2.7°–7.0°, P < 0.001). In contrast, 119 (29.0%) of the hips demonstrated larger measurements of the LCEA on 25 XR relative to CT. Of these hips, 20 (16.8%) had pincer-FAI and 25 had cam-FAI (21.0%), representing a significantly higher proportion compared with all other clinical subgroups (P = 0.045 and 0.036, respectively). Our study demonstrates measured values of the LCEA are consistently inflated on CT relative to XR for a wide variety of hip pathologies, highlighting the need for standardization and validation of CT-based measurements to improve the quality of clinical decision making. Level of Evidence: Diagnostic Level II. PMID:27011864

  7. Patient-specific Analysis of Cartilage and Labrum Mechanics in Human Hips with Acetabular Dysplasia

    PubMed Central

    Henak, Corinne R; Abraham, Christine L; Anderson, Andrew E; Maas, Steve A; Ellis, Benjamin J; Peters, Christopher L; Weiss, Jeffrey A

    2014-01-01

    BACKGROUND Acetabular dysplasia is a major predisposing factor for development of hip osteoarthritis, and may result from alterations to chondrolabral loading. Subject-specific finite element (FE) modeling can be used to evaluate chondrolabral mechanics in the dysplastic hip, thereby providing insight into mechanics that precede osteoarthritis. OBJECTIVE To evaluate chondrolabral contact mechanics and congruency in dysplastic hips and normal hips using a validated approach to subject-specific FE modeling. METHODS FE models of ten subjects with normal acetabula and ten subjects with dysplasia were constructed using a previously validated protocol. Labrum load support, and labrum and acetabular cartilage contact stress and contact area were compared between groups. Local congruency was determined at the articular surface for two simulated activities. RESULTS The labrum in dysplastic hips supported 2.8 to 4.0 times more of the load transferred across the joint than in normal hips. Dysplastic hips did not have significantly different congruency in the primary load-bearing regions than normal hips, but were less congruent in some unloaded regions. Normal hips had larger cartilage contact stress than dysplastic hips in the few regions that had significant differences. CONCLUSIONS The labrum in dysplastic hips has a far more significant role in hip mechanics than it does in normal hips. The dysplastic hip is neither less congruent than the normal hip, nor subjected to elevated cartilage contact stresses. This study supports the concept of an outside-in pathogenesis of osteoarthritis in dysplastic hips and that the labrum in dysplastic hips should be preserved during surgery. PMID:24269633

  8. Prophylactic radiotherapy against heterotopic ossification following internal fixation of acetabular fractures: a comparative estimate of risk

    PubMed Central

    Nasr, P; Yip, G; Scaife, J E; House, T; Thomas, S J; Harris, F; Owen, P J; Hull, P

    2014-01-01

    Objective: Radiotherapy (RT) is effective in preventing heterotopic ossification (HO) around acetabular fractures requiring surgical reconstruction. We audited outcomes and estimated risks from RT prophylaxis, and alternatives of indometacin or no prophylaxis. Methods: 34 patients underwent reconstruction of acetabular fractures through a posterior approach, followed by a 8-Gy single fraction. The mean age was 44 years. The mean time from surgery to RT was 1.1 days. The major RT risk is radiation-induced fatal cancer. The International Commission on Radiological Protection (ICRP) method was used to estimate risk, and compared with a method (Trott and Kemprad) specifically for estimating RT risk for benign disease. These were compared with risks associated with indometacin and no prophylaxis. Results: 28 patients (82%) developed no HO; 6 developed Brooker Class I; and none developed Class II–IV HO. The ICRP method suggests a risk of fatal cancer in the range of 1 in 1000 to 1 in 10,000; the Trott and Kemprad method suggests 1 in 3000. For younger patients, this may rise to 1 in 2000; and for elderly patients, it may fall to 1 in 6000. The risk of death from gastric bleeding or perforation from indometacin is 1 in 180 to 1 in 900 in older patients. Without prophylaxis risk of death from reoperation to remove HO is 1 in 4000 to 1 in 30,000. Conclusion: These results are encouraging, consistent with much larger series and endorse our multidisciplinary management. Risk estimates can be used in discussion with patients. Advances in knowledge: The risk from RT prophylaxis is small, it is safer than indometacin and substantially overlaps with the range for no prophylaxis. PMID:25089852

  9. Design and construction of a fast ion loss Faraday cup array diagnostic for Joint European Torus

    SciTech Connect

    Darrow, D.S.; Baeumel, S.; Cecil, F.E.; Kiptily, V.; Ellis, R.; Pedrick, L.; Werner, A.

    2004-10-01

    A thin foil Faraday cup array is being built to measure the loss of 3.5 MeV alpha particles and MeV ion cyclotron heating tail ions on Joint European Torus. It will consist of nine detectors spread over five different poloidal locations and three radial positions. They will measure the poloidal distribution and radial scrape off of the losses. The detectors will be comprised of four layers of thin (2.5 {mu}m) Ni foil, giving some resolution of the lost particle energy distribution as different ranges of energies will stop in different layers of the detector. One detector will utilize eight thinner (1.0 {mu}m) foils to obtain a better-resolved energy distribution. These detectors will accept particles incident up to 45 deg. from the normal to the foils.

  10. Slit disk for modified faraday cup diagnostic for determining power density of electron and ion beams

    DOEpatents

    Teruya, Alan T.; Elmer; John W.; Palmer, Todd A.

    2011-03-08

    A diagnostic system for characterization of an electron beam or an ion beam includes an electrical conducting disk of refractory material having a circumference, a center, and a Faraday cup assembly positioned to receive the electron beam or ion beam. At least one slit in the disk provides diagnostic characterization of the electron beam or ion beam. The at least one slit is located between the circumference and the center of the disk and includes a radial portion that is in radial alignment with the center and a portion that deviates from radial alignment with the center. The electron beam or ion beam is directed onto the disk and translated to the at least one slit wherein the electron beam or ion beam enters the at least one slit for providing diagnostic characterization of the electron beam or ion beam.

  11. Design and Construction of a Fast Ion Loss Faraday Cup Array Diagnostic for JET

    SciTech Connect

    D.S. Darrow; S. Bauumel; F.E. Cecil; V. Kiptily; R. Ellis; L. Pedrick; A. Werner

    2004-04-26

    A thin foil Faraday cup array is being built to measure the loss of 3.5 MeV alpha particles and MeV ion cyclotron heating (ICH) tail ions on JET. It will consist of nine detectors spread over five different poloidal locations and three radial positions. They will measure the poloidal distribution and radial scrape off of the losses. The detectors will be comprised of four layers of thin (2.5 micron) Ni foil, giving some resolution of the lost particle energy distribution as different ranges of energies will stop in different layers of the detector. One detector will utilize eight thinner (1.0 micron) foils to obtain a better resolved energy distribution. These detectors will accept particles incident up to 45{sup o} from the normal to the foils.

  12. Multiple data sets and modelling choices in a comparative LCA of disposable beverage cups.

    PubMed

    van der Harst, Eugenie; Potting, José; Kroeze, Carolien

    2014-10-01

    This study used multiple data sets and modelling choices in an environmental life cycle assessment (LCA) to compare typical disposable beverage cups made from polystyrene (PS), polylactic acid (PLA; bioplastic) and paper lined with bioplastic (biopaper). Incineration and recycling were considered as waste processing options, and for the PLA and biopaper cup also composting and anaerobic digestion. Multiple data sets and modelling choices were systematically used to calculate average results and the spread in results for each disposable cup in eleven impact categories. The LCA results of all combinations of data sets and modelling choices consistently identify three processes that dominate the environmental impact: (1) production of the cup's basic material (PS, PLA, biopaper), (2) cup manufacturing, and (3) waste processing. The large spread in results for impact categories strongly overlaps among the cups, however, and therefore does not allow a preference for one type of cup material. Comparison of the individual waste treatment options suggests some cautious preferences. The average waste treatment results indicate that recycling is the preferred option for PLA cups, followed by anaerobic digestion and incineration. Recycling is slightly preferred over incineration for the biopaper cups. There is no preferred waste treatment option for the PS cups. Taking into account the spread in waste treatment results for all cups, however, none of these preferences for waste processing options can be justified. The only exception is composting, which is least preferred for both PLA and biopaper cups. Our study illustrates that using multiple data sets and modelling choices can lead to considerable spread in LCA results. This makes comparing products more complex, but the outcomes more robust. PMID:25037049

  13. The Cup'ik People of the Western Tundra: A Curriculum.

    ERIC Educational Resources Information Center

    Pingayak, John

    The Cup'ik people are a group of Yup'ik Eskimos who live in southwest Alaska. This curriculum aims to enhance Cup'ik students' interest in their own culture by making that culture a part of their daily activities; to teach students to practice the traditional Cup'ik respect for elders, fellow students, and others in the community; and to teach…

  14. Acetabular revision with impaction bone grafting and a cemented polyethylene acetabular component: comparison of the Kaplan-Meier analysis to the competing risk analysis in 62 revisions with 25 to 30 years follow-up.

    PubMed

    Te Stroet, M A J; Keurentjes, J C; Rijnen, W H C; Gardeniers, J W M; Verdonschot, N; Slooff, T J J H; Schreurs, B W

    2015-10-01

    We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). We performed Kaplan-Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint 're-revision for any reason' was 58.0% (95% confidence interval (CI) 38 to 73) and for 're-revision for aseptic loosening' 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years. PMID:26430007

  15. Power output during women's World Cup road cycle racing.

    PubMed

    Ebert, Tammie R; Martin, David T; McDonald, Warren; Victor, James; Plummer, John; Withers, Robert T

    2005-12-01

    Little information exists on the power output demands of competitive women's road cycle racing. The purpose of our investigation was to document the power output generated by elite female road cyclists who achieved success in FLAT and HILLY World Cup races. Power output data were collected from 27 top-20 World Cup finishes (19 FLAT and 8 HILLY) achieved by 15 nationally ranked cyclists (mean +/- SD; age: 24.1+/-4.0 years; body mass: 57.9+/-3.6 kg; height: 168.7+/-5.6 cm; VO2max 63.6+/-2.4 mL kg(-1) min(-1); peak power during graded exercise test (GXT(peak power)): 310+/-25 W). The GXT determined GXT(peak power), VO2peak lactate threshold (LT) and anaerobic threshold (AT). Bicycles were fitted with SRM powermeters, which recorded power (W), cadence (rpm), distance (km) and speed (km h(-1)). Racing data were analysed to establish time in power output and metabolic threshold bands and maximal mean power (MMP) over different durations. When compared to HILLY, FLAT were raced at a similar cadence (75+/-8 vs. 75+/-4 rpm, P=0.93) but higher speed (37.6+/-2.6 vs. 33.9+/-2.7 km h(-1), P=0.008) and power output (192+/-21 vs. 169+/-17 W, P=0.04; 3.3+/-0.3 vs. 3.0+/-0.4 W kg(-1), P=0.04). During FLAT races, riders spent significantly more time above 500 W, while greater race time was spent between 100 and 300 W (LT-AT) for HILLY races, with higher MMPs for 180-300 s. Racing terrain influenced the power output profiles of our internationally competitive female road cyclists. These data are the first to define the unique power output requirements associated with placing well in both flat and hilly women's World Cup cycling events. PMID:16151832

  16. Changes in the treatment of acetabular fractures over 15 years: Analysis of 1266 cases treated by the German Pelvic Multicentre Study Group (DAO/DGU).

    PubMed

    Ochs, Björn Gunnar; Marintschev, Ivan; Hoyer, Heike; Rolauffs, Bernd; Culemann, Ulf; Pohlemann, Tim; Stuby, Fabian Maria

    2010-08-01

    Epidemiological, clinical and radiological data of 1266 patients with a unilateral acetabular fracture of up to 29 hospitals was reviewed. Three time periods, 1991-1993 (Registry I; n=359), 1998-2000 (Registry II; n=503), and 2005-2006 (Registry III; n=404) were compared with regard to injury pattern and severity, fracture type, and chosen nonoperative vs. operative treatment to elucidate changes over time in the treatment of acetabular fractures. In the operatively treated group, time to operation, surgical approach, fracture fixation implants and fracture reduction quality were examined. 641 (50.6%) patients with isolated acetabular fractures, 410 (32.4%) multiple injured and 215 (17.0%) polytrauma patients with 642 (50.7%) simple and 624 (49.3%) associated acetabular fractures were evaluated. In the time period from 1991 to 2006, the rate of operative treatments increased nationwide to 77% (rho<0.001). The distribution of fracture types involving the anterior and posterior wall changed with age (rho<0.001). Across all registries, 583 (68.0%) operations were performed within 7 days, 212 (24.7%) operations between 7 and 14 days and 54 (6.3%) operations were performed later than 14 days after injury. An anatomical reduction (0-1mm displacement) was achieved in 551 (64%) acetabular fractures. The obtained reduction quality did not correlate with time to operation, was lower in associated than in simple fracture types, and also lower in patients with isolated acetabular fractures than in polytrauma patients. Most importantly, the fracture reduction quality did not improve over time despite a higher frequency of surgical interventions. The Kocher-Langenbeck approach was preferred in the nineties in nearly three quarters of all operative procedures. Currently, the Kocher-Langenbeck and the ilioinguinal approaches are used equally often. The fracture fixation did not change over time and is achieved in 51% with plates in combination with single screws. This multisurgeon

  17. A Reliability-Based Particle Filter for Humanoid Robot Self-Localization in RoboCup Standard Platform League

    PubMed Central

    Sánchez, Eduardo Munera; Alcobendas, Manuel Muñoz; Noguera, Juan Fco. Blanes; Gilabert, Ginés Benet; Simó Ten, José E.

    2013-01-01

    This paper deals with the problem of humanoid robot localization and proposes a new method for position estimation that has been developed for the RoboCup Standard Platform League environment. Firstly, a complete vision system has been implemented in the Nao robot platform that enables the detection of relevant field markers. The detection of field markers provides some estimation of distances for the current robot position. To reduce errors in these distance measurements, extrinsic and intrinsic camera calibration procedures have been developed and described. To validate the localization algorithm, experiments covering many of the typical situations that arise during RoboCup games have been developed: ranging from degradation in position estimation to total loss of position (due to falls, ‘kidnapped robot’, or penalization). The self-localization method developed is based on the classical particle filter algorithm. The main contribution of this work is a new particle selection strategy. Our approach reduces the CPU computing time required for each iteration and so eases the limited resource availability problem that is common in robot platforms such as Nao. The experimental results show the quality of the new algorithm in terms of localization and CPU time consumption. PMID:24193098

  18. A reliability-based particle filter for humanoid robot self-localization in RoboCup Standard Platform League.

    PubMed

    Munera Sánchez, Eduardo; Muñoz Alcobendas, Manuel; Blanes Noguera, Juan Fco; Benet Gilabert, Ginés; Simó Ten, José E

    2013-01-01

    This paper deals with the problem of humanoid robot localization and proposes a new method for position estimation that has been developed for the RoboCup Standard Platform League environment. Firstly, a complete vision system has been implemented in the Nao robot platform that enables the detection of relevant field markers. The detection of field markers provides some estimation of distances for the current robot position. To reduce errors in these distance measurements, extrinsic and intrinsic camera calibration procedures have been developed and described. To validate the localization algorithm, experiments covering many of the typical situations that arise during RoboCup games have been developed: ranging from degradation in position estimation to total loss of position (due to falls, 'kidnapped robot', or penalization). The self-localization method developed is based on the classical particle filter algorithm. The main contribution of this work is a new particle selection strategy. Our approach reduces the CPU computing time required for each iteration and so eases the limited resource availability problem that is common in robot platforms such as Nao. The experimental results show the quality of the new algorithm in terms of localization and CPU time consumption. PMID:24193098

  19. An Effective and Feasible Method, “Hammering Technique,” for Percutaneous Fixation of Anterior Column Acetabular Fracture

    PubMed Central

    Zhang, Lihai; Zhang, Wei; Li, Tongtong; Li, Jiantao; Chen, Hua

    2016-01-01

    Objective. The objective of this study was to evaluate the effectiveness and advantages of percutaneous fixation of anterior column acetabular fracture with “hammering technique.” Materials and Methods. We retrospectively reviewed 16 patients with percutaneous fixation of anterior column acetabular fracture with “hammering technique.” There were 11 males and 5 females with an average age of 38.88 years (range: 24–54 years) in our study. Our study included 7 nondisplaced fractures, 6 mild displaced fractures (<2 mm), and 5 displaced fractures (>2 mm). The mean time from injury to surgery was 4.5 days (range: 2–7 days). Results. The average of operation time was 27.56 minutes (range: 15–45 minutes), and the mean blood loss was 55.28 mL (range: 15–100 mL). The mean fluoroscopic time was 54.78 seconds (range: 40–77 seconds). The first pass of the guide wire was acceptable without cortical perforation or intra-articular perforation in 88.89% (16/18) of the procedures, and the second attempt was in 11.11% (2/18). Conclusion. Our study suggested that percutaneous fixation of anterior column acetabular fracture with “hammering technique” acquired satisfying surgical and clinical outcomes. It may be an alternative satisfying treatment for percutaneous fixation of anterior column acetabular fracture by 2D fluoroscopy using a C-arm with less fluoroscopic time. PMID:27493962

  20. Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim

    PubMed Central

    Bonneau, Noémie; Bouhallier, July; Baylac, Michel; Tardieu, Christine; Gagey, Olivier

    2012-01-01

    Understanding the three-dimensional orientation of the coxo-femoral joint remains a challenge as an accurate three-dimensional orientation ensure an efficient bipedal gait and posture. The quantification of the orientation of the acetabulum can be performed using the three-dimensional axis perpendicular to the plane that passes along the edge of the acetabular rim. However, the acetabular rim is not regular as an important indentation in the anterior rim was observed. An innovative cadaver study of the labrum was developed to shed light on the proper quantification of the three-dimensional orientation of the acetabulum. Dissections on 17 non-embalmed corpses were performed. Our results suggest that the acetabular rim is better represented by an anterior plane and a posterior plane rather than a single plane along the entire rim as it is currently assumed. The development of the socket from the Y-shaped cartilage was suggested to explain the different orientations in these anterior and posterior planes. The labrum forms a plane that takes an orientation in between the anterior and posterior parts of the acetabular rim, filling up inequalities of the bony rim. The vectors VL, VA2 and VP, representing the three-dimensional orientation of the labrum, the anterior rim and the posterior rim, are situated in a unique plane that appears biomechanically dependent. The three-dimensional orientation of the acetabulum is a fundamental parameter to understand the hip joint mechanism. Important applications for hip surgery and rehabilitation, as well as for physical anthropology, were discussed. PMID:22360458

  1. Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results

    PubMed Central

    Sandri, Andrea

    2014-01-01

    Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC). Twenty-nine patients (32 implants) died for unrelated causes without additional surgery. Sixty-five hips were available for clinical and radiographic assessment at an average follow-up of 14.6 years (range, 10.0 to 18.9 years). There were 16 male and 49 female patients, aged from 29 to 83 (median, 60 years), with Paprosky IIIA (27 cases) and IIIB (38 cases) acetabular bone defects. Nine cages required rerevision because of infection (3), aseptic loosening (5), and flange breakage (1). The average Harris hip score improved from 33.1 points preoperatively to 75.6 points at follow-up (P < 0.001). Radiographically, graft incorporation and cage stability were detected in 48 and 52 hips, respectively. The cumulative survival rates at 18.9 years with removal for any reason or X-ray migration of the cage and aseptic or radiographic loosening as the end points were 80.0% and 84.6%, respectively. The use of the Burch-Schneider APC and massive allografts is an effective technique for the reconstructive treatment of extensive acetabular bone loss with long-lasting survival. PMID:24967339

  2. Studies in Cup Drawing Behavior of Polymer Laminated Sheet Metal

    NASA Astrophysics Data System (ADS)

    Elnagmi, M.; Jain, M.; Bruhis, M.; Nielsen, K.

    2011-08-01

    Axisymmetric deep drawing behavior of a polymer laminated sheet metal (PLSM) is investigated using an axisymmetric cup drawing test. PLSMs are of interest as a replacement for painted finishes for automotive applications as they have the potential to achieve good quality long lasting and aesthetically appealing surfaces on stamped parts. However, there is limited understanding of PLSMs in automotive deep drawing situations to produce complex 3-D parts. The tests are carried out using well-controlled, laboratory-based, dual-action, servo-hydraulic forming presses under blank-holder force and punch displacement control conditions. An optical strain mapping system is used to measure the surface strains (and to construct 3D strain maps) from the film side of the deformed samples for a range of forming conditions. Deep drawing characteristics such as punch load versus punch displacement traces, strain distribution along the cup profile, flange wrinkling and fracture characteristics are experimentally assessed for stainless steel-plastic film laminated sheet materials. Also the effect of lamination pressure on wrinkling and delamination is investigated for a decorative pressure sensitive adhesive film affixed to the stainless steel sheet.

  3. Influence of the meteorology mast on a cup anemometer

    SciTech Connect

    Hansen, M.O.L.; Maribo Pedersen, B.

    1996-10-01

    In order to measure the efficiency of a wind turbine the non-dimensional power coefficient C{sub p} is measured as a function of the tip speed ratio. The power is non-dimensionalized with respect to the density, the swept area by the rotor and the third power of the wind speed. Since C{sub p} depends on the third power of the wind speed it is very important to measure the wind speed accurately. The wind speed is usually measured by a cup anemometer mounted on a rod which is mounted on a meteorology mast. The mast will often be a lattice construction consisting of three main beams shored up by smaller beams. The mast is a long slender construction, which gives an almost two-dimensional flow round a cross-section at a certain height above the ground. The cylindrical beams will give a local distortion of the wind speed in the vicinity of the mast. If the rod, on which the cup anemometer is mounted, is to short one will measure a wrong wind speed and thus a wrong power coefficient C{sub p}. To the authors knowledge only Cermak and Horn (1968) and Gill et al. (1967) approached the problem experimentally by wind tunnel measurements on scale models. In this paper a simple numerical approach is taken to model the flow around the mast.

  4. Self-organizing actin waves as planar phagocytic cup structures

    PubMed Central

    Ecke, Mary; Schroth-Diez, Britta; Gerwig, Silke; Engel, Ulrike; Maddera, Lucinda; Clarke, Margaret

    2009-01-01

    Actin waves that travel on the planar membrane of a substrate-attached cell underscore the capability of the actin system to assemble into dynamic structures by the recruitment of proteins from the cytoplasm. The waves have no fixed shape, can reverse their direction of propagation and can fuse or divide. Actin waves separate two phases of the plasma membrane that are distinguished by their lipid composition. The area circumscribed by a wave resembles in its phosphoinositide content the interior of a phagocytic cup, leading us to explore the possibility that actin waves are in-plane phagocytic structures generated without the localized stimulus of an attached particle. Consistent with this view, wave-forming cells were found to exhibit a high propensity for taking up particles. Cells fed rod-shaped particles produced elongated phagocytic cups that displayed a zonal pattern that reflected in detail the actin and lipid pattern of free-running actin waves. Neutrophils and macrophages are known to spread on surfaces decorated with immune complexes, a process that has been interpreted as “frustrated” phagocytosis. We suggest that actin waves enable a phagocyte to scan a surface for particles that might be engulfed. PMID:19855162

  5. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

    SciTech Connect

    Hu Jing; Rovey, Joshua L.

    2011-07-15

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 {Omega} characteristic impedance to match with 50 {Omega} standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

  6. Automated detection of kinks from blood vessels for optic cup segmentation in retinal images

    NASA Astrophysics Data System (ADS)

    Wong, D. W. K.; Liu, J.; Lim, J. H.; Li, H.; Wong, T. Y.

    2009-02-01

    The accurate localization of the optic cup in retinal images is important to assess the cup to disc ratio (CDR) for glaucoma screening and management. Glaucoma is physiologically assessed by the increased excavation of the optic cup within the optic nerve head, also known as the optic disc. The CDR is thus an important indicator of risk and severity of glaucoma. In this paper, we propose a method of determining the cup boundary using non-stereographic retinal images by the automatic detection of a morphological feature within the optic disc known as kinks. Kinks are defined as the bendings of small vessels as they traverse from the disc to the cup, providing physiological validation for the cup boundary. To detect kinks, localized patches are first generated from a preliminary cup boundary obtained via level set. Features obtained using edge detection and wavelet transform are combined using a statistical approach rule to identify likely vessel edges. The kinks are then obtained automatically by analyzing the detected vessel edges for angular changes, and these kinks are subsequently used to obtain the cup boundary. A set of retinal images from the Singapore Eye Research Institute was obtained to assess the performance of the method, with each image being clinically graded for the CDR. From experiments, when kinks were used, the error on the CDR was reduced to less than 0.1 CDR units relative to the clinical CDR, which is within the intra-observer variability of 0.2 CDR units.

  7. 76 FR 39289 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ..., 2008, issue of the Federal Register (73 FR 3316). Public Meeting We do not now plan to hold a public... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit... waters immediately prior to, during, and immediately after the Detroit APBA Gold Cup boat race....

  8. 75 FR 21191 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-23

    ..., 2008 issue of the Federal Register (73 FR 3316). Public Meeting We do not now plan to hold a public... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit... vessels from portions of the Detroit River during the Detroit APBA Gold Cup. This special local...

  9. 75 FR 39448 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ... Federal Register (75 FR 21191). We received zero comments on the proposed rule. No public meeting was... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit... Detroit River during the Detroit APBA Gold Cup. This special local regulation is necessary to...

  10. 77 FR 25073 - Special Local Regulation; Hebda Cup Rowing Regatta, Trenton Channel; Detroit River, Wyandotte, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ... SECURITY Coast Guard 33 CFR Part 100 RIN 1625-AA08 Special Local Regulation; Hebda Cup Rowing Regatta... on the navigable waters immediately prior to, during, and immediately after the Hebda Cup Rowing... Purpose On April 28, 2012, the Wyandotte Boat Club is holding a rowing race that will require...

  11. Contact of dual mobility implants: effects of cup wear and inclination.

    PubMed

    Uddin, M S

    2015-01-01

    Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies. PMID:25023708

  12. 77 FR 14423 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items, and Packaging Thereof; Notice...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... COMMISSION Certain Food Containers, Cups, Plates, Cutlery, and Related Items, and Packaging Thereof; Notice... Related Items, and Packaging Thereof, DN 2883; the Commission is soliciting comments on any public... containers, cups, plates, cutlery, and related items, and packaging thereof. The complaint names...

  13. Athletic Departments' Operating Expenses as a Predictor of Their Directors' Cup Standing

    ERIC Educational Resources Information Center

    Magner, Amber

    2014-01-01

    The NACDA Directors' Cup is a competition utilizing an unbiased scoring system that encourages a broad based athletic department as the standard for defining intercollegiate athletic success. Therefore, for NCAA DI athletic administrators the Directors' Cup should be the standard for defining intercollegiate athletic success. The purpose of this…

  14. 33 CFR 165.T11-0551 - Safety Zone; America's Cup Sailing Events.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... provisions of 33 CFR 165.23 apply to this safety zone. No person or vessel underway may enter or remain... Sailing Events. 165.T11-0551 Section 165.T11-0551 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... § 165.T11-0551 Safety Zone; America's Cup Sailing Events. (a) Definitions—(1) America's Cup...

  15. 77 FR 60897 - Safety Zone: America's Cup World Series Finish-Line, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... INFORMATION: Table of Acronyms APA Administrative Procedure Act DHS Department of Homeland Security FR Federal... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone: America's Cup World Series Finish-Line, San... support of the 2012 America's Cup World Series sailing events. This safety zone is established to...

  16. 77 FR 7025 - Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... Federal Register (73 FR 3316). Public Meeting We do not now plan to hold a public meeting. But you may... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zones; America's Cup World Series, East Passage... Bay, Rhode Island, during the America's Cup World Series sailing vessel racing event. This safety...

  17. 77 FR 28253 - Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... Series, East Passage, Narragansett Bay, RI'' in the Federal Register (77 FR 7025). We received one... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; America's Cup World Series, East Passage... the America's Cup World Series (ACWS) sailing vessel racing event. DATES: This rule is effective...

  18. 77 FR 54815 - Safety Zone: America's Cup World Series Regattas, San Francisco Bay; San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... INFORMATION: Table of Acronyms ACRM America's Cup Race Management DHS Department of Homeland Security FR... public dockets in the January 17, 2008, issue of the Federal Register (73 FR 3316). 4. Public Meeting We... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone: America's Cup World Series Regattas,...

  19. 78 FR 37712 - Safety Zone; Chicago Match Cup Race; Lake Michigan; Chicago, IL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... SECURITY Coast Guard 33 CFR Part 165 Safety Zone; Chicago Match Cup Race; Lake Michigan; Chicago, IL AGENCY... safety zone on Lake Michigan near Chicago, Illinois for the 2013 AWMRT Chicago Match Cup Race. This zone... being enforced without permission of the Captain of the Port, Lake Michigan. DATES: This regulation...

  20. The efficacy of wet-cupping in the treatment of tension and migraine headache.

    PubMed

    Ahmadi, Alireza; Schwebel, David C; Rezaei, Mansour

    2008-01-01

    Wet-cupping is an ancient medical technique still used in several contemporary societies, but little empirical study has been devoted to test its efficacy to treat tension and migraine headache. Using a pre-post research design, 70 patients with chronic tension or migraine headache were treated with wet-cupping. Three primary outcome measures were considered at the baseline and 3 months following treatment: headache severity, days of headache per month, and use of medication. Results suggest that, compared to the baseline, mean headache severity decreased by 66% following wet-cupping treatment. Treated patients also experienced the equivalent of 12.6 fewer days of headache per month. We conclude that wet-cupping leads to clinical relevant benefits for primary care patients with headache. Possible mechanisms of wet-cupping's efficacy, as well as directions for future research are discussed. PMID:18306448

  1. The pvc operon regulates the expression of the Pseudomonas aeruginosa fimbrial chaperone/usher pathway (cup) genes.

    PubMed

    Qaisar, Uzma; Luo, Liming; Haley, Cecily L; Brady, Sean F; Carty, Nancy L; Colmer-Hamood, Jane A; Hamood, Abdul N

    2013-01-01

    The Pseudomonas aeruginosa fimbrial structures encoded by the cup gene clusters (cupB and cupC) contribute to its attachment to abiotic surfaces and biofilm formation. The P. aeruginosa pvcABCD gene cluster encodes enzymes that synthesize a novel isonitrile functionalized cumarin, paerucumarin. Paerucumarin has already been characterized chemically, but this is the first report elucidating its role in bacterial biology. We examined the relationship between the pvc operon and the cup gene clusters in the P. aeruginosa strain MPAO1. Mutations within the pvc genes compromised biofilm development and significantly reduced the expression of cupB1-6 and cupC1-3, as well as different genes of the cupB/cupC two-component regulatory systems, roc1/roc2. Adjacent to pvc is the transcriptional regulator ptxR. A ptxR mutation in MPAO1 significantly reduced the expression of the pvc genes, the cupB/cupC genes, and the roc1/roc2 genes. Overexpression of the intact chromosomally-encoded pvc operon by a ptxR plasmid significantly enhanced cupB2, cupC2, rocS1, and rocS2 expression and biofilm development. Exogenously added paerucumarin significantly increased the expression of cupB2, cupC2, rocS1 and rocS2 in the pvcA mutant. Our results suggest that pvc influences P. aeruginosa biofilm development through the cup gene clusters in a pathway that involves paerucumarin, PtxR, and different cup regulators. PMID:23646138

  2. The pvc Operon Regulates the Expression of the Pseudomonas aeruginosa Fimbrial Chaperone/Usher Pathway (Cup) Genes

    PubMed Central

    Qaisar, Uzma; Luo, Liming; Haley, Cecily L.; Brady, Sean F.; Carty, Nancy L.; Colmer-Hamood, Jane A.; Hamood, Abdul N.

    2013-01-01

    The Pseudomonas aeruginosa fimbrial structures encoded by the cup gene clusters (cupB and cupC) contribute to its attachment to abiotic surfaces and biofilm formation. The P. aeruginosa pvcABCD gene cluster encodes enzymes that synthesize a novel isonitrile functionalized cumarin, paerucumarin. Paerucumarin has already been characterized chemically, but this is the first report elucidating its role in bacterial biology. We examined the relationship between the pvc operon and the cup gene clusters in the P. aeruginosa strain MPAO1. Mutations within the pvc genes compromised biofilm development and significantly reduced the expression of cupB1-6 and cupC1-3, as well as different genes of the cupB/cupC two-component regulatory systems, roc1/roc2. Adjacent to pvc is the transcriptional regulator ptxR. A ptxR mutation in MPAO1 significantly reduced the expression of the pvc genes, the cupB/cupC genes, and the roc1/roc2 genes. Overexpression of the intact chromosomally-encoded pvc operon by a ptxR plasmid significantly enhanced cupB2, cupC2, rocS1, and rocS2 expression and biofilm development. Exogenously added paerucumarin significantly increased the expression of cupB2, cupC2, rocS1 and rocS2 in the pvcA mutant. Our results suggest that pvc influences P. aeruginosa biofilm development through the cup gene clusters in a pathway that involves paerucumarin, PtxR, and different cup regulators. PMID:23646138

  3. Germline genetics of cancer of unknown primary (CUP) and its specific subtypes

    PubMed Central

    Hemminki, Kari; Chen, Bowang; Kumar, Abhishek; Melander, Olle; Manjer, Jonas; Hallmans, Göran; Pettersson-Kymmer, Ulrika; Ohlsson, Claes; Folprecht, Gunnar; Löffler, Harald; Krämer, Alwin; Försti, Asta

    2016-01-01

    Cancer of unknown primary site (CUP) is a fatal cancer diagnosed through metastases at various organs. Little is known about germline genetics of CUP which appears worth of a search in view of reported familial associations in CUP. In the present study, samples from CUP patients were identified from 2 Swedish biobanks and a German clinical trial, totaling 578 CUP patients and 7628 regionally matched controls. Diagnostic data specified the organ where metastases were diagnosed. We carried out a genome-wide association study on CUP cases and controls. In the whole sample set, 6 loci reached an allelic p-value in the range of 10−7 and were supported by data from the three centers. Three associations were located next to non-coding RNA genes. rs2660852 flanked 5′UTR of LTA4H (leukotriene A4 hydrolase), rs477145 was intronic to TIAM1 (T-cell lymphoma invasion and metastases) and rs2835931 was intronic to KCNJ6 (potassium channel, inwardly rectifying subfamily J, member 6). In analysis of subgroups of CUP patients (smokers, non-smokers and CUP with liver metastases) genome-wide significant associations were noted. For patients with liver metastases associations on chromosome 6 and 11, the latter including a cluster of genes DHCR7 and NADSYN1, encoding key enzymes in cholesterol and NAD synthesis, and KRTAP5-7, encoding a keratin associated protein. This first GWAS on CUP provide preliminary evidence that germline genes relating to inflammation (LTA4H), metastatic promotion (TIAM1) in association with lipid metabolic disturbance (chromosome 11 cluster) may contribute to the risk of CUP. PMID:26959888

  4. Validation of a computer-assisted method for measurement of radiographic wear in total hip arthroplasty using all polyethylene cemented acetabular components.

    PubMed

    Langlois, Jean; Zaoui, Amine; Scemama, Caroline; Martell, John; Bragdon, Charles; Hamadouche, Moussa

    2015-03-01

    Although cemented all polyethylene (PE) cups have been routinely used in total hip arthroplasty for decades, no computer-assisted method for measurement of radiographic wear has ever been specifically validated for these implants. Using a validated hip phantom model, AP plain hip radiographs were obtained consecutively for eight simulated wear positions. A version of Martell's Hip Analysis Suite software dedicated to all polyethylene sockets was used by three different examiners of varied experience. Bias (mean, standard deviation and 95% confidence interval limit), repeatability (standard deviation and 95% limit) and reproducibility (standard deviation and 95% limit) for two-dimensional wear measurements were assessed, as recommended by the current ASTM guidelines. Using this protocol, the dedicated software showed an overall mean bias of 0.089 ± 0.060 mm (mean ± SD), and 0.118 mm for 95% CI limit. Repeatability (intra examiner) standard deviation and 95% limit were respectively 0.106 mm and 0.292 mm. Reproducibility (inter examiner) standard deviation and 95% limit were respectively 0.112 mm and 0.308 mm. Martell Hip Analysis for all PE cemented cups is a reliable and low-cost instrument in the assessment of wear, despite being less precise than its original version dedicated to cementless components. PMID:25564735

  5. Arthroscopic Bone Grafting of Deep Acetabular Cysts Using a Curved Delivery Device

    PubMed Central

    Garabekyan, Tigran; Chadayammuri, Vivek; Pascual-Garrido, Cecilia; Mei-Dan, Omer

    2016-01-01

    Acetabular intraosseous cysts are frequently encountered in patients with dysplasia or femoroacetabular impingement. Small cysts are typically addressed by removing the cyst lining and stimulating healing via microfracture or abrasion chondroplasty. In contrast, larger cysts involving 1-3 cm3 frequently require additional fortification with bone graft material to facilitate osseous ingrowth and cyst healing. Previous arthroscopic reports have described the use of rim trimming to access the extra-articular side of the cyst, with subsequent use of straight metal cannulas for delivery of bone graft material. The downsides of this technique include the requirement for rim trimming, which may be ill advised in patients with normal coverage or dysplasia, as well as the creation of a second breach in the cyst wall, precluding pressurization of the bone graft material. We describe an arthroscopic technique using a curved delivery device allowing for deeper penetration into the cyst cavity through the articular side and greater delivery of bone graft material. PMID:27073770

  6. Radiographic evaluation of HDPE cemented and cementless Lord and An.C.A. screwed acetabular models.

    PubMed

    Toni, A; Sudanese, A; Viceconti, M; Montina, P P; Ciaroni, D; Calista, F; Terzi, S; Giunti, A

    1992-01-01

    A total of 187 alumina screwed porous-ceramic coated sockets (An.C.A.), 48 screwed smooth-surfaced Lord sockets, and 251 cemented polyethylene sockets were radiographically evaluated at an average follow-up of 30, 51 and 96 months respectively. After 6 years the Lord prostheses revealed a 38% incidence of loosening, similar to that observed for cemented sockets 10-12 years after surgery. The An.C.A. prostheses revealed radiographic loosening equal to 12% (6 cases) in the first 50 implants, and only 0.7% in the remaining 137 cases: overall, the An.C.A. acetabular prosthesis revealed an index of radiographic loosening equal to 3.3% (7/187). To guarantee "osteointegration" of the porous coating of An.C.A. sockets optimal stability must be obtained when the prosthesis is screwed in. Because the mid-term follow-up for this clinical experience is relatively short (30 months), an opinion on the reliability of the screwed "porous" sockets must await confirmation. PMID:1297574

  7. Retrieved Highly Crosslinked UHMWPE Acetabular Liners Have Similar Wear Damage as Conventional UHMWPE

    PubMed Central

    Schroder, David T.; Kelly, Natalie H.; Parks, Michael L.

    2010-01-01

    Background Highly crosslinked UHMWPE is associated with increased wear resistance in hip simulator and clinical studies. Laboratory and case studies, however, have described rim fracture in crosslinked acetabular liners. Controversy exists, therefore, on the relative merits of crosslinked liners over conventional liners in terms of wear performance versus resistance to fatigue cracking. Questions/purposes We asked whether crosslinked liners would show less surface damage than conventional liners but would be more susceptible to fatigue damage. Methods We examined 36 conventional UHMWPE and 39 crosslinked UHMWPE retrieved implants with similar patient demographics and identical design for evidence of wear damage, including articular surface damage, impingement, screw-hole creep, and rim cracks. Results We observed no difference in wear damage scores for the two liners. Conventional liners more frequently impinged but were more often elevated with smaller head sizes. We observed creep in approximately 70% of both types of liners. Incipient rim cracks were found in five crosslinked liners, and one liner had a rim fracture. Only one conventional liner had an incipient rim crack. Conclusions Contrary to our expectation, damage was similar between crosslinked and conventional UHMWPE liners. Moreover, the 15% occurrence (six of 39) of incipient or complete fractures in crosslinked liners as compared with a 3% occurrence (one of 36) in conventional liners may have implications for the long-term performance of crosslinked liners. Longer-term studies will be necessary to establish the fate of rim cracks and thus the overall clinical fatigue performance of crosslinked liners. PMID:20844998

  8. Retrieval analysis of a failed TriboFit polycarbonate urethane acetabular buffer.

    PubMed

    Biant, Leela C; Gascoyne, Trevor C; Bohm, Eric R; Moran, Matthew

    2016-03-01

    The purpose of this research was to determine the failure mechanisms and damage features of a TriboFit acetabular buffer implanted directly against a native, prepared acetabulum which was revised after 11months. Retrieval analyses were carried out via light microscopy, gravimetric wear assessment, and observer scoring of visible damage features on the buffer. The volume of material abraded from the backside of the buffer was estimated via three-dimensional reconstruction using a laser scanner. Scanning electron microscopy was used to confirm damage features and mechanisms. Severe abrasion to the backside of the buffer was the primary damage feature, while stippling damage was seen on the articular surface of the buffer. Material loss due to backside abrasion was approximated to be between 0.13360.085 g (gravimetric analyses) and 0.19360.053 g (three-dimensional reconstruction). Implantation of the TriboFit buffer against the patient's native acetabulum without a metal backing allowed for significant movement of the buffer against the bone, resulting in the abrasion seen on this implant. The stippling damage on the articular surface indicates an adhesive wear mechanism which exacerbates movement of the buffer against the acetabulum, thereby increasing backside abrasion. PMID:26833696

  9. The effect of femoro-acetabular impingement on the kinematics and kinetics of the hip joint.

    PubMed

    Alshameeri, Zeiad; Khanduja, Vikas

    2014-08-01

    Gait analysis is an objective tool that has been used to assess and monitor treatment for many musculoskeletal conditions. Recently, it has been used to assess the impact of femoro-acetabular impingement (FAI) on the hip and lower limb movements. There have been a fairly limited number of studies published so far reporting unexpected and inconsistent results, which calls for more research to be conducted in this arena. In the light of the limited data available, it has been challenging to reconcile the contradictions in some of these results, and therefore no coherent conclusions could be drawn. In this short article, we attempt to explain some of the abnormal kinematic and kinetic patterns associated with FAI by highlighting similarities between the gait seen in early osteoarthritis (OA) and that of FAI. We also propose an approach for future research in this field and emphasise the importance of quantifying early OA in FAI based on magnetic resonance imaging (MRI) scans and the amount of chondral damage seen during open or arthroscopic surgery. PMID:24687267

  10. The Relationship of Acetabular Dysplasia and Femoroacetabular Impingement to Hip Osteoarthritis: A Focused Review

    PubMed Central

    Royer, Nathaniel K.

    2012-01-01

    Hip osteoarthritis (OA) leads to significant functional limitations and economic burden. If modifiable risk factors for hip OA are identified, it may be possible to implement preventative measures. Bony abnormalities associated with acetabular dysplasia (AD) and femoroacetabular impingement (FAI) have been recently implicated as risk factors for hip osteoarthritis (OA). The purpose of this focused review is to summarize the available evidence describing the relationship between bony abnormalities and hip OA. A librarian-assisted database search using PubMed, Embase and Central was performed. Relevant articles were identified and assessed for inclusion criteria. The authors reviewed cohort and case control studies that reported on the association between abnormal hip morphology and hip OA. The available literature suggests that an association exists between bony abnormalities found in AD and FAI and hip OA and preliminary evidence suggests that AD is a risk factor for OA, however these conclusions are based on limited evidence. Prospective, longitudinal studies are needed to confirm the causal relationship between abnormal hip morphology and the future development of hip OA. PMID:22108232

  11. Computed Tomography-Based Software Safely Guides Anterograde Percutaneous Anterior and Posterior Column Acetabular Screws.

    PubMed

    Banerjee, Soham; Starr, Adam J; Banerjee, Rahul

    2016-01-01

    The objective of this study was to develop three-dimensional (3-D) modeling software to generate the optimal individualized starting points and pathways for anterior and posterior column screws. In this cross-sectional study, 95 consecutive patients from a level I trauma center with noncontrast pelvis computed tomography (CT) images without displaced acetabular fractures were studied. A Java-based program was designed that generated a 3-D graph of pelvic bones and a list was compiled of every potential anterograde anterior and posterior column screw that exited distal to the acetabulum, eliminating screws that did not safely remain within the cortex. The longest safe screw pathway for each patient was determined for both 6.5-mm and 7.3-mm diameter screws. The program was able to identify safe screw pathways for the vast majority of patients (>96%). The study also found that males tolerated significantly longer screws in the anterior column (p < .05), but there was no posterior column difference regarding sex. PMID:27518290

  12. Effects of acetabular resurfacing component material and fixation on the strain distribution in the pelvis.

    PubMed

    Thompson, M S; Northmore-Ball, M D; Tanner, K E

    2002-01-01

    A 3D finite element (FE) model of an implanted pelvis was developed as part of a project investigating an all-polymer hip resurfacing design. The model was used to compare this novel design with a metal-on-metal design in current use and a metal-on-polymer design typical of early resurfacing implants. The model included forces representing the actions of 22 muscles as well as variable cancellous bone stiffness and variable cortical shell thickness. The hip joint reaction force was applied via contact modelled between the femoral and acetabular components of the resurfacing prosthesis. Five load cases representing time points through the gait cycle were analysed. The effect of varying fixation conditions was also investigated. The highest cancellous bone strain levels were found at mid-stance, not heel-strike. Remote from the acetabulum there was little effect of prosthesis material and fixation upon the von Mises stresses and maximum principal strains. Implant material appeared to have little effect upon cancellous bone strain failure with both bended and unbonded bone-implant interfaces. The unbonded implants increased stresses in the subchondral bone at the centre of the acetabulum and increased cancellous bone loading, resembling behaviour obtained previously for the intact acetabulum. PMID:12206520

  13. Tranexamic acid reduces the blood loss and blood transfusion requirements following peri-acetabular osteotomy.

    PubMed

    Wassilew, G I; Perka, C; Janz, V; Krämer, M; Renner, L

    2015-12-01

    We have investigated the effect of using tranexamic acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative blood loss and blood transfusion requirements. In addition we analysed whether the use of TXA was associated with an increased risk of venous thromboembolism (VTE) following this procedure. A consecutive series of 96 PAOs, performed by a single surgeon, were reviewed. A total of 48 patients received TXA and 48 did not. The TXA group received a continuous infusion of TXA at a rate of 10 mg/kg/h. The primary outcome measure was the requirement for blood transfusion. Secondary outcomes included total blood loss, the decrease in the level of haemoglobin in the blood, the length of hospital stay, and the complications of this treatment. The mean rate of transfusion was significantly lower in the TXA group (62.5% vs 12.5%, p < 0.001). The mean blood loss was also significantly reduced in the TXA group (1.9 L (standard deviation (SD) 0.9) vs 1.5 L (SD 0.7), p < 0.01). No post-operative episodes of VTE were identified in either group. The use of TXA reduced the blood loss and the rate of transfusion after PAO significantly, without adverse effects such as an increased rate of VTE. PMID:26637672

  14. Communities of constructional lips and cup reef rims in Bermuda

    NASA Astrophysics Data System (ADS)

    Thomas, Martin L. H.; Stevens, Jo-Anne

    1991-01-01

    Constructional lips and cup reef rims are little studied reef features typical of very turbulent conditions. The relatively low diversity community of these structures consists of three components, and algal mat dominated by Herposiphonia secunda, an encrusting calcareous biota characterised by crustose coralline algae and the vermetid gastropod Dendropoma corrodens, which together are the main hermatypic components, and an endolithic component with very abundant boring sponges, polychaetes, crustaceans and sipunculids. In northerly areas of Bermuda, the hydrozoan Millepora alcicornis is a prominent member of the community while to the south the urchin Echinometra lucunter is abundant. On the south side of Bermuda the community traps sediment which is deposited in the void spaces. The environment shows reduced grazing and this may account for the presence of several relict and rare species.

  15. Domestic science: making chemistry your cup of tea.

    PubMed

    Keene, Melanie

    2008-03-01

    In the early Victorian home, there were plenty of scientific lessons to be uncovered. With the appropriate interrogation, everyday objects could transform seemingly mundane activities such as eating breakfast, washing clothes or reading by candle-light into household lectures that gave children a familiar base from which to explore the hidden properties and marvellous histories of common commodities. Responding to an unprecedented hunger for scientific knowledge, a profusion of introductory texts appeared in the mid-nineteenth century that directed lessons into homes across Britain and beyond. In particular, the science of chemistry found its way into this domestic setting, as writers promoted its practice and practitioners as a source of authoritative expertise on everyday life. One of the most compelling illustrations of this encounter between the public and chemistry took place over a simple cup of tea. PMID:18328565

  16. Cup waveguide antenna with integrated polarizer and OMT

    NASA Technical Reports Server (NTRS)

    Acosta, Roberto J. (Inventor); Kory, Carol (Inventor); Lambert, Kevin M. (Inventor)

    2011-01-01

    A cup waveguide antenna with integrated polarizer and OMT for simultaneously communicating left and right hand circularly polarized electromagnetic waves is adjustable to obtain efficient propagation and reception of electromagnetic waves. The antenna includes a circular waveguide having an orthomode transducer utilizing first and second pins longitudinally spaced apart and oriented orthogonally with respect to each other. Six radially-oriented adjustable polarizer screws extend from the exterior to the interior of the waveguide. A septum intermediate the first and second pins is aligned with the first pin. Adjustment of the polarizer screws enables maximized propagation of and/or response to left hand circularly polarized electromagnetic waves by the first pin while simultaneously enabling maximized propagation of and/or response to right hand circularly polarized electromagnetic waves by the second pin.

  17. Lycurgus Cup: inverse problem using photographs for characterization of matter.

    PubMed

    Barchiesi, Dominique

    2015-08-01

    Photographs of the Lycurgus Cup with a source light inside and outside exhibit purple and green colors, respectively (dichroism). A model relying on the scattering of light to colors in the photographs is proposed and used within an inverse problem algorithm, to deduce radius and composition of metallic particles, and the refractive index of the surrounding glass medium. The inverse problem algorithm is based on a hybridization of particle swarm optimization and of the simulated annealing methods. The results are compared to experimental measurements on a small sample of glass. The linear laws that are deduced from sets of possible parameters producing the same color in the photographs help simplify the understanding of phenomena. The proportion of silver to gold in nanoparticles is found to be in agreement, but a large proportion of copper is also found. The retrieved refractive index of the surrounding glass is close to 2. PMID:26367298

  18. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    PubMed Central

    Sinha, Skand; Naik, Ananta k; Arya, Rajendra K; Jain, Vijay K

    2013-01-01

    Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS) plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. PMID:27298928

  19. Cementless press-fit cup. Principles, experimental data, and three-year follow-up study.

    PubMed

    Morscher, E; Bereiter, H; Lampert, C

    1989-12-01

    The concept of the press-fit cup includes an operative defect as small as possible, achievement of intrinsic stability by press-fit, and surface coating by an orderly, oriented wire mesh coating. The design is a modified hemisphere with flattening in the pole area and oversized cup diameter. A first series of press-fit cups were fitted with titanium nitride-coated stainless steel mesh. The manufacturing of such chemically pure titanium has only recently become feasible. Animal experiments using mountain sheep have shown an increase in the stability of the press-fit cup within the acetabulum with time and progressive bony ingrowth; this was verified in cups retrieved at autopsy. Three hundred eighty-seven first-generation titanium nitride-coated stainless steel mesh implants have been reviewed with a follow-up time of 12 to 39 months (average, 16.6 months). There were no intraoperative complications related to the cup. The roentgenographic follow-up study of 330 (85.1%) hips showed only a single case with a radiolucent line in all zones (1-3) as a roentgenographic sign of loosening, i.e., fibrous ingrowth. Two cups had to be revised due to insufficient primary stability and tilting. PMID:2582662

  20. Prediction of specialty coffee cup quality based on near infrared spectra of green coffee beans.

    PubMed

    Tolessa, Kassaye; Rademaker, Michael; De Baets, Bernard; Boeckx, Pascal

    2016-04-01

    The growing global demand for specialty coffee increases the need for improved coffee quality assessment methods. Green bean coffee quality analysis is usually carried out by physical (e.g. black beans, immature beans) and cup quality (e.g. acidity, flavour) evaluation. However, these evaluation methods are subjective, costly, time consuming, require sample preparation and may end up in poor grading systems. This calls for the development of a rapid, low-cost, reliable and reproducible analytical method to evaluate coffee quality attributes and eventually chemical compounds of interest (e.g. chlorogenic acid) in coffee beans. The aim of this study was to develop a model able to predict coffee cup quality based on NIR spectra of green coffee beans. NIR spectra of 86 samples of green Arabica beans of varying quality were analysed. Partial least squares (PLS) regression method was used to develop a model correlating spectral data to cupping score data (cup quality). The selected PLS model had a good predictive power for total specialty cup quality and its individual quality attributes (overall cup preference, acidity, body and aftertaste) showing a high correlation coefficient with r-values of 90, 90,78, 72 and 72, respectively, between measured and predicted cupping scores for 20 out of 86 samples. The corresponding root mean square error of prediction (RMSEP) was 1.04, 0.22, 0.27, 0.24 and 0.27 for total specialty cup quality, overall cup preference, acidity, body and aftertaste, respectively. The results obtained suggest that NIR spectra of green coffee beans are a promising tool for fast and accurate prediction of coffee quality and for classifying green coffee beans into different specialty grades. However, the model should be further tested for coffee samples from different regions in Ethiopia and test if one generic or region-specific model should be developed. PMID:26838420

  1. Wear of the polyethylene liner-metallic shell interface in modular acetabular components. An in vitro analysis.

    PubMed

    Lieberman, J R; Kay, R M; Hamlet, W P; Park, S H; Kabo, J M

    1996-08-01

    The purpose of this study was to determine the effect of compression cycles and wear patterns on the polyethylene liner-metallic shell interface in modular acetabular components. Articular frictional torque was also measured. Modular acetabular components from five manufacturers were tested. The polyethylene liners were sputter coated with gold on the convex surface to enhance the visualization of wear and deformation patterns. Each component was cycled for 10 million cycles in a hydraulic fatigue testing machine. Frictional torque was measured prior to the start of the cyclic loading and in increments of 2 million cycles. Frictional torque was significantly lower in the design with an enhanced polyethylene liner. Abrasion of the gold from the convex surface of polyethylene liners varied from 2 to 23% between designs. Extrusion of the polyethylene into the screw holes in the metallic shells was universal. Three modes of damage (burnishing, punch-out, and gouging) were identified on the convex surface of the polyethylene liner. Abrasion of the gold from the convex surface of the polyethylene varied greatly between designs. This is indicative of relative motion between the polyethylene liner and the metallic shell. This motion must be minimized to limit the generation of wear debris from the convex surface of the polyethylene. Several aspects of modular acetabular component design could be implemented to potentially reduce wear, including limiting the number of holes available for screw placement, smoothing out the edges of the screw holes to avoid punch-out, and avoiding supplemental fixation of the liner unless it is essential to prevent motion between the liner and the metallic shell. PMID:8872582

  2. Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum

    PubMed Central

    Henak, C.R.; Abraham, C.L.; Peters, C.L.; Sanders, R.K.; Weiss, J.A.; Anderson, A.E.

    2014-01-01

    AIM To develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum. MATERIALS AND METHODS Ninety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured. RESULTS Using the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (~5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98–6.7 mm (2.46 ± 1.16 mm). CONCLUSIONS When applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required. PMID:25070373

  3. Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components.

    PubMed

    Takahashi, Yasuhito; Tateiwa, Toshiyuki; Shishido, Takaaki; Masaoka, Toshinori; Kubo, Kosuke; Yamamoto, Kengo

    2016-10-01

    The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs). PMID:27454526

  4. Operational experience using the novel FixCup collecting main valve

    SciTech Connect

    Giertz, J.; Huhn, F.; Spitz, J.

    1996-12-31

    On the occasion of the 1995 AIME conference the new PROven (Pressure Regulated Oven) process to control the pressure in coke ovens individually was introduced. This process was made feasible with a new collecting main valve, termed FixCup, with the aid of this valve a variable flow resistance to the raw gas discharge can be realized using a water immersion system. However, just the application of the FixCup system alone--without any pressure regulation--is very advantageous and cost saving. Thyssen has equipped 30 ovens with the new valve. The special constructive features as well as the operational experience using the FixCup valve are treated.

  5. Successful Long-Term Fixation and Progression of Osteolysis Associated with First-Generation Cementless Acetabular Components Retrieved Post Mortem

    PubMed Central

    Urban, Robert M.; Hall, Deborah J.; Della Valle, Craig; Wimmer, Markus A.; Jacobs, Joshua J.; Galante, Jorge O.

    2012-01-01

    Background: Primary cementless acetabular reconstruction has shown durable long-term fixation. Late failures secondary to aseptic loosening are rare but may occur in patients with previously well-fixed components. In the present study, the histopathological characteristics of postmortem specimens were correlated with wear damage and radiographic data in an attempt to better understand the long-term events in the periacetabular tissue around well-functioning devices. Methods: Seventeen primary cementless Harris-Galante I acetabular components with adjacent tissues were harvested after a mean of eleven years (range, four to twenty-five years) from patients whose implants were well functioning at the time of death. Undecalcified and paraffin sections were used to quantify the extent of bone and soft tissues within the porous coating and at the interface between the coating and the surrounding bone. Wear particles were identified with use of polarized light microscopy and energy-dispersive x-ray analysis. Bearing-surface volumetric wear and backside wear damage of the polyethylene liner were assessed. Results: All of the components were fixed by bone ingrowth (mean extent, 33% ± 21%). Particle-induced granulomas were present in the porous coating and along the interface and progressed through screw holes, ballooning into the retroacetabular bone in the longer-term specimens. Particles of femoral and acetabular origin were identified in the granulomas. Bearing-surface volumetric wear (mean, 41.6 mm3/year) increased with duration and correlated with increasing extent of granuloma in the porous coating and the increasing size of pelvic granulomas. Radiolucencies on radiographs correlated with the extent of bone and fibrous tissue ingrowth. Of the six pelvic granulomas that were identified histologically, only one was apparent on routine radiographs. Conclusions: Acetabular fixation by bone ingrowth can be successful into the third decade after implantation. Osteolysis

  6. An analysis of hylamer and polyethylene bearings from retrieved acetabular components.

    PubMed

    Collier, J P; Bargmann, L S; Currier, B H; Mayor, M B; Currier, J H; Bargmann, B C

    1998-08-01

    Hylamer and conventional polyethylene acetabular liners of the same design, revised for a variety of reasons, were examined and compared to assess the performance of Hylamer as a bearing material. Clinical damage modes, linear wear rates, oxidation levels, and mechanical properties were measured. In both series, many liners were retrieved for dislocation. Wear/osteolysis was the most common reason for retrieval in the Hylamer series, while none of the conventional polyethylene liners were retrieved for this reason. Nearly all liners exhibited abrasion, burnishing, scratching, and creep. The Hylamer liners had more cracking, delamination, and pitting. The Hylamer liners had an average linear wear rate of 0.32 mm/year, while the conventional polyethylene liners had an average wear rate of 0.20 mm/year. Due to sample size, no statistical difference in wear rate was noted between the two groups. In general, both the Hylamer and conventional polyethylene showed oxidation peaks subsurface, resulting from their exposure to gamma radiation in air. Liners with elevated oxidation had decreased ultimate tensile strength, elongation, and toughness. For given oxidation levels, the corresponding mechanical properties of Hylamer appeared lower than those of conventional polyethylene. The ultimate tensile strength values ranged from 14 to 33 MPa for Hylamer and 19 to 32 MPa for conventional polyethylene. Elongation ranges were 19% to 350% (Hylamer) and 80% to 375% (conventional). The Hylamer retrievals in this study gave initial indications of performance; Hylamer appeared to behave similarly, but not superiorly, to conventional polyethylene, in the early functional period with respect to clinical wear and clinical performance. Both Hylamer and conventional polyethylene liners were degraded by gamma sterilization in air, with Hylamer liners demonstrating greater property changes. PMID:9731668

  7. Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearings made of hylamer.

    PubMed

    Scott, D L; Campbell, P A; McClung, C D; Schmalzried, T P

    2000-01-01

    There have been several reports of osteolysis associated with rapid wear of Hylamer. A detailed analysis of retrieved implants and tissues can identify factors contributing to rapid wear and osteolysis. The mean linear wear rate of 12 liners was 0.49 mm/y, and 11 of 12 hips had progressive retroacetabular osteolysis. The average patient age was 50 years, and the mean implantation time was 50 months. All liners were sterilized by gamma irradiation in air. There was an 11-month difference in the average shelf-life of the 3 liners that were white and those that were darker in color. The volumetric wear rate of the white liners was 30% less than that of the others, suggesting a difference in the wear resistance of the liners as a function of shelf life. The mean average surface roughness (Ra) and the mean maximum surface roughness (R(max)) of the femoral heads were increased 3-fold and 50-fold compared with typical values for unused femoral heads. Evidence of 3-body wear, such as metal particles embedded in the liners, was commonly present. The pattern of backside liner deformation and burnishing was consistent with relative motion between the liner and the shell. In addition to generating Hylamer wear particles, repetitive axial motion between the liner and shell could generate fluid pressure, which transmitted through holes in the acetabular shell could cause or contribute to the development of retroacetabular osteolysis. Hylamer particles of variable shape and size, consistent with generation by several wear modes, were isolated from periprosthetic tissues. PMID:10654460

  8. Can T1-rho MRI detect acetabular cartilage degeneration in femoroacetabular impingement?: a pilot study.

    PubMed

    Rakhra, K S; Lattanzio, P-J; Cárdenas-Blanco, A; Cameron, I G; Beaulé, P E

    2012-09-01

    Advanced MRI cartilage imaging such as T(1)-rho (T1ρ) for the diagnosis of early cartilage degradation prior to morpholgic radiological changes may provide prognostic information in the management of joint disease. This study aimed first to determine the normal T1ρ profile of cartilage within the hip, and secondly to identify any differences in T1ρ profile between the normal and symptomatic femoroacetabular impingement (FAI) hip. Ten patients with cam-type FAI (seven male and three female, mean age 35.9 years (28 to 48)) and ten control patients (four male and six female, mean age 30.6 years (22 to 35)) underwent 1.5T T1ρ MRI of a single hip. Mean T1ρ relaxation times for full thickness and each of the three equal cartilage thickness layers were calculated and compared between the groups. The mean T1ρ relaxation times for full cartilage thickness of control and FAI hips were similar (37.17 ms (SD 9.95) and 36.71 ms (SD 6.72), respectively). The control group demonstrated a T1ρ value trend, increasing from deep to superficial cartilage layers, with the middle third having significantly greater T1ρ relaxation values than the deepest third (p = 0.008). The FAI group demonstrated loss of this trend. The deepest third in the FAI group demonstrated greater T1ρ relaxation values than controls (p = 0.028). These results suggest that 1.5T T1ρ MRI can detect acetabular hyaline cartilage changes in patients with FAI. PMID:22933489

  9. Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial.

    PubMed

    Devane, P A; Robinson, E J; Bourne, R B; Rorabeck, C H; Nayak, N N; Horne, J G

    1997-05-01

    We measured the three-dimensional wear of polyethylene after total hip arthroplasty with a titanium metal-backed Mallory-Head prosthesis that was inserted with cement in sixty-nine patients (sixty-nine hips) and with a press-fit titanium metal-backed Mallory-Head prosthesis that was inserted without cement in seventy patients (seventy hips). A modular titanium femoral head was used in all of the hips. The patients in the present study were part of a larger double-blind randomized trial comparing the result of total hip arthroplasty performed with cement with that of the same procedure performed without cement in 250 patients. The criterion for inclusion in the study of polyethylene wear was a minimum duration of follow-up of four years, which was met by 148 patients. As adequate radiographs for digitization were not available for nine patients, 139 patients were included in the present study. The age of the patient, the postoperative Harris hip score, the diameter of the femoral head, the thickness of the liner in the polar region of the acetabular component, and the duration of follow-up were similar for the two groups. The mean rate of volumetric wear of the polyethylene was significantly greater in the prostheses that had been inserted without cement than in those that had been inserted with cement (155.1 cubic millimeters per year compared with 98.5 cubic millimeters per year; p = 0.000008). Thirty-four (49 per cent) of the seventy hips in which the prosthesis had been inserted without cement had evidence of osteolysis on radiographs, compared with twelve (17 per cent) of the sixty-nine hips in the other group (p = 0.0002). Osteolysis was associated with an increased rate of polyethylene wear only in the hips in which the prosthesis had been inserted without cement. PMID:9160940

  10. Mechanistic Based DEM Simulation of Particle Attrition in a Jet Cup

    SciTech Connect

    Xu, Wei; DeCroix, David; Sun, Xin

    2014-02-01

    The attrition of particles is a major industrial concern in many fluidization systems as it can have undesired effects on the product quality and on the reliable operation of process equipment. Therefore, to accomodate the screening and selection of catalysts for a specific process in fluidized beds, risers, or cyclone applications, their attrition propensity is usually estimated through jet cup attrition testing, where the test material is subjected to high gas velocities in a jet cup. However, this method is far from perfect despite its popularity, largely due to its inconsistency in different testing set-ups. In order to better understand the jet cup testing results as well as their sensitivity to different operating conditions, a coupled computational fluid dynamic (CFD) - discrete element method (DEM) model has been developed in the current study to investigate the particle attrition in a jet cup and its dependence on various factors, e.g. jet velocity, initial particle size, particle density, and apparatus geometry.

  11. Forecasting a winner for Malaysian Cup 2013 using soccer simulation model

    NASA Astrophysics Data System (ADS)

    Yusof, Muhammad Mat; Fauzee, Mohd Soffian Omar; Latif, Rozita Abdul

    2014-07-01

    This paper investigates through soccer simulation the calculation of the probability for each team winning Malaysia Cup 2013. Our methodology used here is we predict the outcomes of individual matches and then we simulate the Malaysia Cup 2013 tournament 5000 times. As match outcomes are always a matter of uncertainty, statistical model, in particular a double Poisson model is used to predict the number of goals scored and conceded for each team. Maximum likelihood estimation is use to measure the attacking strength and defensive weakness for each team. Based on our simulation result, LionXII has a higher probability in becoming the winner, followed by Selangor, ATM, JDT and Kelantan. Meanwhile, T-Team, Negeri Sembilan and Felda United have lower probabilities to win Malaysia Cup 2013. In summary, we find that the probability for each team becominga winner is small, indicating that the level of competitive balance in Malaysia Cup 2013 is quite high.

  12. Coffee to Go: Woman "Thinks" First Cup in 15 Years | NIH MedlinePlus the Magazine

    MedlinePlus

    ... this page please turn Javascript on. Feature: NIBIB Robotics Coffee to Go: Woman "Thinks" First Cup in ... own—using her thoughts alone to direct a robotic arm to her lips. The feat was made ...

  13. Comparison of attrition test methods: ASTM standard fluidized bed vs jet cup

    SciTech Connect

    Zhao, R.; Goodwin, J.G. Jr.; Jothimurugesan, K.; Spivey, J.J.; Gangwal, S.K.

    2000-05-01

    Attrition resistance is one of the key design parameters for catalysts used in fluidized-bed and slurry phase types of reactors. The ASTM fluidized-bed test has been one of the most commonly used attrition resistance evaluation methods; however, it requires the use of 50 g samples--a large amount for catalyst development studies. Recently a test using the jet cup requiring only 5 g samples has been proposed. In the present study, two series of spray-dried iron catalysts were evaluated using both the ASTM fluidized-bed test and a test based on the jet cup to determine this comparability. It is shown that the two tests give comparable results. This paper, by reporting a comparison of the jet-cup test with the ASTM standard, provides a basis for utilizing the more efficient jet cup with confidence in catalyst attrition studies.

  14. Region-based multi-step optic disk and cup segmentation from color fundus image

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Lock, Jane; Manresa, Javier Moreno; Vignarajan, Janardhan; Tay-Kearney, Mei-Ling; Kanagasingam, Yogesan

    2013-02-01

    Retinal optic cup-disk-ratio (CDR) is a one of important indicators of glaucomatous neuropathy. In this paper, we propose a novel multi-step 4-quadrant thresholding method for optic disk segmentation and a multi-step temporal-nasal segmenting method for optic cup segmentation based on blood vessel inpainted HSL lightness images and green images. The performance of the proposed methods was evaluated on a group of color fundus images and compared with the manual outlining results from two experts. Dice scores of detected disk and cup regions between the auto and manual results were computed and compared. Vertical CDRs were also compared among the three results. The preliminary experiment has demonstrated the robustness of the method for automatic optic disk and cup segmentation and its potential value for clinical application.

  15. Tungsten insulated susceptor cup for high temperature induction furnace eliminates contamination

    NASA Technical Reports Server (NTRS)

    Geringer, H. J.

    1966-01-01

    METILUR /Materials Experimental Tungsten Induction Laboratory Unit Replacement/ is an improved, unitized design of a susceptor cup and shielding that uses only one type of construction material /tungsten/ which eliminates contamination. Cycling runs can be accomplished with METILUR.

  16. Corking Nitrogen-Doped Carbon Nanotube Cups with Gold Nanoparticles for Biodegradable Drug Delivery Applications.

    PubMed

    Burkert, Seth C; Star, Alexander

    2015-01-01

    Carbon nanomaterials have been proposed as effective drug delivery devices; however their perceived biopersistence and toxicological profile may hinder their applications in medical therapeutics. Nitrogen doping of carbon nanotubes results in a unique "stacked-cup" structure, with cups held together through van der Waals forces. Disrupting these weak interactions yields individual and short-stacked nanocups that can subsequently be corked with gold nanoparticles, resulting in sealed containers for delivery of cargo. Peroxidase-catalyzed reactions can effectively uncork these containers, followed by complete degradation of the graphitic capsule, resulting in effective release of therapeutic cargo while minimizing harmful side effects. The protocols reported herein describe the synthesis of stacked nitrogen-doped carbon nanotube cups followed by effective separation into individual cups and gold nanoparticle cork formation resulting in loaded and sealed containers. PMID:26629615

  17. Our Everyday Cup of Coffee: The Chemistry behind Its Magic

    NASA Astrophysics Data System (ADS)

    Petracco, Marino

    2005-08-01

    Coffee beverages are so popular all over the world that there is hardly any need to describe them. But underlying this seemingly commonplace beverage there is a whole realm worth serious scientific study. The complexity of the raw seed matrix, made even more intricate when roasted, requires a deep understanding of its chemical nature. While coffee is not consumed for nutritional purposes, it is appreciated for its taste appeal along with its stimulating effects on mental and physical activity. The attention to quality is of paramount importance to both of these aspects to supply the customers with a pleasant and wholesome product. The chemical approach to the sensory sphere has seen the development of increasingly sophisticated analytical methods where the parts per billion of volatile aromas are not the ultimate frontier of detection limits. In spite of the progress of instrumental techniques, the cup-testing approach still remains the final assessment tool to obtain the approval for choosing the right plant and for conveying the product to the market. This is even truer when espresso, the fashionable type of coffee brewing methods, is considered.

  18. Supra-acetabular fixation and sacroiliac screws for treating unstable pelvic ring injuries: preliminary results from 20 patients☆

    PubMed Central

    Guimarães, Rodrigo Pereira; de Góes Ribeiro, Arthur; Ulson, Oliver; de Ávila, Ricardo Bertozzi; Ono, Nelson Keiske; Polesello, Giancarlo Cavalli

    2016-01-01

    Objective To analyze the treatment results from 20 patients who underwent an alternative osteosynthesis method as definitive treatment for pelvic ring fractures. Methods A retrospective analysis was conducted on a series of 20 patients with pelvic ring fractures (Tile type C) and a high risk of postoperative infection, who were treated at Santa Casa de Misericórdia de São Paulo between August 2004 and December 2012. The patients underwent percutaneous supra-acetabular external fixation in association with cannulated 7.0 mm iliosacral screws. Results The patients’ mean age was 40 years (range 22–77 years) and the mean length of follow-up was 18.5 months (range 3–69 months). At the end of the treatment, ten patients (50%) were classified as having good results, nine patients (45%) had fair results and one patient (5%) did not have any improvement. Six patients presented complications, and paresthesia of the lateral femoral cutaneous nerve was the most frequent of these (two patients). Conclusion Supra-acetabular external fixation in association with iliosacral percutaneous osteosynthesis is a good definitive treatment method for patients with a high risk of postoperative infection. PMID:27069879

  19. Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images

    NASA Astrophysics Data System (ADS)

    Hatanaka, Yuji; Noudo, Atsushi; Muramatsu, Chisako; Sawada, Akira; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi

    2010-03-01

    Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. First, the blood vessels were erased from the image and then the edge of optic disc was then detected by use of a canny edge detection filter. Twenty profiles were then obtained around the center of the optic disc in the vertical direction on blue channel of the color image, and the profile was smoothed by averaging these profiles. After that, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method. These results indicated that this method can be useful for the analysis of the optic disc in glaucoma examinations.

  20. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey.

    PubMed

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  1. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    PubMed Central

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  2. The long-term outcome of the cemented Weber acetabular component in total hip replacement using a second-generation cementing technique.

    PubMed

    de Jong, P T; de Man, F H R; Haverkamp, D; Marti, R K

    2009-01-01

    We report the long-term outcome of a modified second-generation cementing technique for fixation of the acetabular component of total hip replacement. An earlier report has shown the superiority of this technique assessed by improved survival compared with first-generation cementing. The acetabular preparation involved reaming only to the subchondral plate, followed by impaction of the bone in the anchorage holes. Between 1978 and 1993, 287 total hip replacements were undertaken in 244 patients with a mean age of 65.3 years (21 to 90) using a hemispherical Weber acetabular component with this modified technique for cementing and a cemented femoral component. The survival with acetabular revision for aseptic loosening as the endpoint was 99.1% (95% confidence interval 97.9 to 100 after ten years and 85.5% (95% confidence interval 74.7 to 96.2) at 20 years. Apart from contributing to a long-lasting fixation of the component, this technique also preserved bone, facilitating revision surgery when necessary. PMID:19092001

  3. Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: a finite element study with biphasic acetabular cartilage properties.

    PubMed

    Li, Junyan; Hua, Xijin; Jin, Zhongmin; Fisher, John; Wilcox, Ruth K

    2014-11-01

    Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries. PMID:24957488

  4. Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties

    PubMed Central

    Li, Junyan; Hua, Xijin; Jin, Zhongmin; Fisher, John; Wilcox, Ruth K.

    2014-01-01

    Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5 mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries. PMID:24957488

  5. Pulsatile dry cupping in patients with osteoarthritis of the knee – a randomized controlled exploratory trial

    PubMed Central

    2012-01-01

    Introduction Cupping is used in various traditional medicine forms to relieve pain in musculoskeletal diseases. The aim of this study was to investigate the effectiveness of cupping in relieving the symptoms of knee osteoarthritis (OA). Methods In a two-group, randomized controlled exploratory pilot study patients with a clinically and radiological confirmed knee OA (Kellgren-Lawrence Grading Scale: 2-4) and a pain intensity > 40 mm on a 100 mm visual analogue scale (VAS) were included. 40 Patients were randomized to either 8 sessions of pulsatile dry cupping within 4 weeks or no intervention (control). Paracetamol was allowed on demand for both groups. Outcomes were the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) score, the pain intensity on a VAS (0 mm = no pain to 100 mm = maximum intensity) and Quality of Life (SF-36) 4 and 12 weeks after randomization. Use of Paracetamol was documented within the 4-week treatment period. Analyses were performed by analysis of covariance adjusting for the baseline value for each outcome. Results 21 patients were allocated to the cupping group (5 male; mean age 68 ± SD 7.2) and 19 to the control group (8 male; 69 ± 6.8). After 4 weeks the WOMAC global score improved significantly more in the cupping group with a mean of 27.7 (95% confidence interval 22.1; 33.3) compared to 42.2 (36.3; 48.1) in the control group (p = 0.001). After 12 weeks the WOMAC global score were still significantly different in favor for cupping (31.0 (24.9; 37.2) vs. 40.8 (34.4; 47.3) p = 0.032), however the WOMAC subscores for pain and stiffness were not significant anymore. Significantly better outcomes in the cupping group were also observed for pain intensity on VAS and for the SF-36 Physical Component Scale compared to the control group after 4 and 12 weeks. No significant difference was observed for the SF-36 Mental Component Scale and the total number of consumed Paracetamol tablets

  6. Early predictors of acetabular growth after closed reduction in late detected developmental dysplasia of the hip.

    PubMed

    Li, YiQiang; Xu, HongWen; Li, JingChun; Yu, LingJia; Liu, YuanZhong; Southern, Edward; Liu, HongSheng

    2015-01-01

    This study evaluates improvement of the acetabular index (AI) in patients with developmental dysplasia of the hip at 4 years after closed reduction, and determines the association between the final AI and a set of factors. Sixty-two patients (74 hips) treated with closed reduction were categorized into three groups according to age: group A (0-12 months, 18 hips), group B (13-18 months, 24 hips), and group C (>18 months, 32 hips). There was no difference in AI among the three groups before reduction (P=0.293). In groups A and C, the AI decreased significantly over time until 3 years after reduction and no differences were observed between the time points of 3 and 4 years. At 4 years after reduction, the AI of group C was significantly higher than that of groups A (P<0.001) and B (P=0.012). The overall AI improvement rate was 28.63%. The AI improvement rate of group A was significantly higher than that of group C (P=0.005). Pearson correlation analysis indicated no correlation between center-head distance discrepancy and the final AI (P=0.811). Linear regression suggested that age and initial AI correlated significantly with the final AI (R=0.617, F=15.031, P<0.001). Other factors, such as sex, center-edge angle of Wiberg, bilaterally involved, and avascular necrosis of the femoral head, showed no correlations with the final AI (P>0.05). According to the coefficients, initial AI (β1=0.432, P<0.001) had greater effect than age (β2=0.197, P=0.023) on the final AI. In conclusion, the AI decreases in all patients after reduction and stabilizes at 3 years after reduction. The AI improvement rate is correlated negatively with age. Age and initial AI are early predictors of the progress of AI after closed reduction in developmental dysplasia of the hip patients. PMID:25305044

  7. Effects of rotational acetabular osteotomy on the mechanical stress within the hip joint in patients with developmental dysplasia of the hip: a subject-specific finite element analysis.

    PubMed

    Ike, H; Inaba, Y; Kobayashi, N; Yukizawa, Y; Hirata, Y; Tomioka, M; Saito, T

    2015-04-01

    In this study we used subject-specific finite element analysis to investigate the mechanical effects of rotational acetabular osteotomy (RAO) on the hip joint and analysed the correlation between various radiological measurements and mechanical stress in the hip joint. We evaluated 13 hips in 12 patients (two men and ten women, mean age at surgery 32.0 years; 19 to 46) with developmental dysplasia of the hip (DDH) who were treated by RAO. Subject-specific finite element models were constructed from CT data. The centre-edge (CE) angle, acetabular head index (AHI), acetabular angle and acetabular roof angle (ARA) were measured on anteroposterior pelvic radiographs taken before and after RAO. The relationship between equivalent stress in the hip joint and radiological measurements was analysed. The equivalent stress in the acetabulum decreased from 4.1 MPa (2.7 to 6.5) pre-operatively to 2.8 MPa (1.8 to 3.6) post-operatively (p < 0.01). There was a moderate correlation between equivalent stress in the acetabulum and the radiological measurements: CE angle (R = -0.645, p < 0.01); AHI (R = -0.603, p < 0.01); acetabular angle (R = 0.484, p = 0.02); and ARA (R = 0.572, p < 0.01). The equivalent stress in the acetabulum of patients with DDH decreased after RAO. Correction of the CE angle, AHI and ARA was considered to be important in reducing the mechanical stress in the hip joint. PMID:25820887

  8. Aerobic power and peak power of elite America's Cup sailors.

    PubMed

    Neville, Vernon; Pain, Matthew T G; Folland, Jonathan P

    2009-05-01

    Big-boat yacht racing is one of the only able bodied sporting activities where standing arm-cranking ('grinding') is the primary physical activity. However, the physiological capabilities of elite sailors for standing arm-cranking have been largely unreported. The purpose of the study was to assess aerobic parameters, VO(2peak) and onset of blood lactate (OBLA), and anaerobic performance, torque-crank velocity and power-crank velocity relationships and therefore peak power (P (max)) and optimum crank-velocity (omega(opt)), of America's Cup sailors during standing arm-cranking. Thirty-three elite professional sailors performed a step test to exhaustion, and a subset of ten grinders performed maximal 7 s isokinetic sprints at different crank velocities, using a standing arm-crank ergometer. VO(2peak) was 4.7 +/- 0.5 L/min (range 3.6-5.5 L/min) at a power output of 332 +/- 44 W (range 235-425 W). OBLA occurred at a power output of 202 +/- 31 W (61% of W(max)) and VO(2) of 3.3 +/- 0.4 L/min (71% of VO(2peak)). The torque-crank velocity relationship was linear for all participants (r = 0.9 +/- 0.1). P (max) was 1,420 +/- 37 W (range 1,192-1,617 W), and omega(opt) was 125 +/- 6 rpm. These data are among the highest upper-body anaerobic and aerobic power values reported. The unique nature of these athletes, with their high fat-free mass and specific selection and training for standing arm cranking, likely accounts for the high values. The influence of crank velocity on peak power implies that power production during on-board 'grinding' may be optimised through the use of appropriate gear-ratios and the development of efficient gear change mechanisms. PMID:19234715

  9. Relative merits of polystyrene foam and paper in hot drink cups: Implications for packaging

    NASA Astrophysics Data System (ADS)

    Hocking, Martin B.

    1991-11-01

    An analysis of the overall relative merits of the use of uncoated paper vs molded polystyrene bead foam in single-use 8-oz cups is described here as a manageable example of the use of paper vs plastics in packaging. In raw material requirements the paper cup required about 2.5 times its finished weight of raw wood and about the same hydrocarbon fueling requirement as is needed for the polystyrene foam cup. To process the raw materials about six times as much steam, 13 times as much electric power, and twice as much cooling water are consumed to produce the paper cup as compared to the polystyrene foam cup. Emission rates to air are similar and to water are generally higher for the paper cup. Virtually all primary use factors favor polystyrene foam over paper. Once used both cup types may be recycled. Landfill disposal of the two items under dry conditions will occupy similar landfill volumes after compaction and will confer similarly slow to nonexistent decomposition to either option. Under wet conditions polystyrene foam will not readily degrade, but may help other materials to do so. Paper under wet conditions will biodegrade to produce methane, a significant greenhouse gas, biochemical oxygen demand to any leachate, and instability to the land surface during the process. Both materials can be incinerated cleanly in a municipal waste stream with the option of energy recovery, to yield an ash volume of 2% 5% of the incoming waste volume. Overall this analysis would suggest that polystyrene foam, with an extension to plastics in general, should be given more evenhanded consideration relative to paper in packaging applications than is currently the case.

  10. Preclinical, Clinical, and Over-the-Counter Postmarketing Experience with a New Vaginal Cup: Menstrual Collection

    PubMed Central

    North, Barbara B.

    2011-01-01

    Abstract Background Menstrual cups have been available for decades, but their use is limited by bulky design and the need for multiple sizes. The Softcup® (Instead, Inc., San Diego, CA) is a simple single-size disposable over-the-counter (OTC) menstrual cup that compresses to tampon shape to facilitate insertion and can be worn during coitus. This report describes preclinical evaluation, clinical testing, and postmarketing monitoring of the Softcup. Methods Preclinical testing complied with U.S. Food and Drug Administration (FDA) guidelines and used standard United States Pharmacopoeia methodologies for assessment of potential toxicity. Clinical testing enrolled 406 women in seven U.S. centers. A detailed written questionnaire assessed safety, acceptability, and effectiveness for menstrual collection. Study safety parameters included pelvic examinations, Pap smears, colposcopy, urinalysis, vaginal pH, wet mounts, gram stain, and vaginal microflora cultures. Postmarketing surveillance of over 100 million Softcups has been conducted by the manufacturer and by the FDA Medwatch system. Results No toxicity or mutagenicity was observed in preclinical evaluations. In clinical testing, after three cycles of cup use, 37% of subjects rated the cup as better than, 29% as worse than, and 34% as equal to pads or tampons. The cup was preferred for comfort, dryness, and less odor. Cups received lower ratings for disposal and convenience. Eighty-one percent of enrolled women were able to insert and remove their first cup using only written instructions. Use difficulties resulting in study discontinuations included cramping (1%), leakage (1%), and improper fit (3%). No safety parameters were adversely affected. No significant health risks were reported during postmarketing surveillance. Conclusions These results demonstrate that a single-size vaginal device has no significant health risks and is acceptable to many women without the need for fitting or other medical services. PMID

  11. No increased risk of early revision during the implementation phase of new cup designs.

    PubMed

    Mohaddes, Maziar; Björk, Mathias; Nemes, Szilard; Rolfson, Ola; Jolbäck, Per; Kärrholm, Johan

    2016-07-01

    Background and purpose - In Sweden, less than 5% of patients who undergo total hip arthroplasty (THA) have revision. Younger patients have an increased risk of revision. New prosthetic designs are being introduced in order to improve outcomes further. We investigated whether the introductory phase of new cup designs would increase the revision rate. Patients and methods - All THAs and first-time cup revisions performed from 1993 through 2011 were identified in the Swedish Hip Arthroplasty Register. The 15 types of cups used in more than 500 operations and inserted in more than 50 cases in each hospital (n = 52,903) were selected. All cups were given an order number, based on the order in which the cup had been inserted at each hospital. The influence of order number on the risk of revision was analyzed in a regression model, which was adjusted for potentially confounding demographic and surgical data. Revision within 2 years for all reasons (n = 940) was used as primary endpoint. Changes in the risk of revision based on the order number were analyzed using a spline. Results - The order number of the cup had no influence on the risk of early revision (p ≥ 0.7). Categorizing the order number using cutoff values obtained from the splines did not result in any statistically significant changes in risk of revision (p ≥ 0.2). Interpretation - We did not find any increased risk of early revision during the implementation phase of new cup designs. This finding is unexpected, and partly conflicts with data from other registries. The structured and stepwise introduction of new prosthesis designs, facilitated by the annual feedback from the Swedish Hip Arthroplasty Register, may partly explain this discrepancy. PMID:27168095

  12. The Use of a 3D Printer in Pre-operative Planning for a Patient Requiring Acetabular Reconstructive Surgery

    PubMed Central

    Duncan, James M; Nahas, Samuel; Akhtar, Kashif; Daurka, Jasvinder

    2015-01-01

    Introduction: Surgical management of acetabular fractures is often highly complex, and a successful outcome depends upon an appreciation of the fracture pattern and the most appropriate approach to reduce and hold it. Currently, computed tomography (CT) images are used in conjunction with plain x-rays to identify the main fracture components and their spatial relationship to one another, and as such surgeons still have to make decisions based upon their ability to visualise the fracture from the images available. 3D printers have now become widely available and inexpensive, and can be used to rapidly produce life-size models based on CT scans of an individual patient. The availability of patient specific, accurate and detailed models of complex acetabular fractures can aid planning of surgical management on a patient specific basis. Case Report: This report describes the use of a 3D printer to create a life-size model reconstruction of the pelvis of a 48 year old male patient who sustained a left sided associated both column acetabular fracture following a motorbike accident in the Sahara Desert. The model allowed visualisation of the multiple fracture fragments and their relative displacements. The tactile feedback allowed assessment of the different fracture fragments. The relative displacement of the quadrilateral plate and posterior column fragments could be assessed and the surgeon felt that these would be amenable to reduction from an ilioinguinal approach. An anatomic reduction was achieved and was held with the application of a pelvic brim plate with 2 screws lagging the posterior column/quadrilateral plate fragment. Conclusion: There are previous examples of 3D models being used in orthopaedic surgery through the use of rapid prototyping, however this method is usually expensive and time consuming. Advances in 3D printer technology offer surgeons a number of advantages when treating these complex fractures. With the ever-increasing economy, ease of use and

  13. ‘There are a lot of new people in town: but they are here for soccer, not for business’ a qualitative inquiry into the impact of the 2010 soccer world cup on sex work in South Africa

    PubMed Central

    2014-01-01

    Background Sports mega-events have expanded in size, popularity and cost. Fuelled by media speculation and moral panics, myths proliferate about the increase in trafficking into forced prostitution as well as sex work in the run-up to such events. This qualitative enquiry explores the perceptions of male, female and transgender sex workers of the 2010 Soccer World Cup held in South Africa, and the impact it had on their work and private lives. Methods A multi-method study design was employed. Data consisted of 14 Focus Group Discussions, 53 sex worker diaries, and responses to two questions in surveys with 1059 male, female and transgender sex workers in three cities. Results Overall, a minority of participants noted changes to the sex sector due to the World Cup and nothing emerged on the feared increases in trafficking into forced prostitution. Participants who observed changes in their work mainly described differences, both positive and negative, in working conditions, income and client relations, as well as police harassment. The accounts of changes were heterogeneous - often conflicting in the same research site and across sites. Conclusions No major shifts occurred in sex work during the World Cup, and only a few inconsequential changes were noted. Sports mega-events provide strategic opportunities to expand health and human rights programmes to sex workers. The 2010 World Cup missed that opportunity. PMID:24915943

  14. Improved automated optic cup segmentation based on detection of blood vessel bends in retinal fundus images.

    PubMed

    Hatanaka, Yuji; Nagahata, Yuuki; Muramatsu, Chisako; Okumura, Susumu; Ogohara, Kazunori; Sawada, Akira; Ishida, Kyoko; Yamamoto, Tetsuya; Fujita, Hiroshi

    2014-01-01

    Glaucoma is a leading cause of permanent blindness. Retinal imaging is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, ophthalmologists may determine the cup and disc areas and diagnose glaucoma using a vertical optic cup-to-disc (C/D) ratio and a rim-to-disc (R/D) ratio. Previously we proposed a method to determine cup edge by analyzing a vertical profile of pixel values, but this method provided a cup edge smaller than that of an ophthalmologist. This paper describes an improved method using the locations of the blood vessel bends. The blood vessels were detected by a concentration feature determined from the density gradient. The blood vessel bends were detected by tracking the blood vessels from the disc edge to the primary cup edge, which was determined by our previous method. Lastly, the vertical C/D ratio and the R/D ratio were calculated. Using forty-four images, including 32 glaucoma images, the AUCs of both the vertical C/D ratio and R/D ratio by this proposed method were 0.966 and 0.936, respectively. PMID:25569913

  15. Antidoping programme and biological monitoring before and during the 2014 FIFA World Cup Brazil

    PubMed Central

    Baume, Norbert; Jan, Nicolas; Emery, Caroline; Mandanis, Béatrice; Schweizer, Carine; Giraud, Sylvain; Leuenberger, Nicolas; Marclay, François; Nicoli, Raul; Perrenoud, Laurent; Robinson, Neil; Dvorak, Jiri; Saugy, Martial

    2015-01-01

    Background The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. Aim To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. Methods All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2–8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. Results The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. Conclusions Logistical issues linked to biological samples collection, and the overseas shipment during the World Cup did not impair the quality of the analyses, especially when used as the biological passport of football players. PMID:25878079

  16. In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals.

    PubMed

    Wannomae, Keith K; Bhattacharyya, Shayan; Freiberg, Andrew; Estok, Daniel; Harris, William H; Muratoglu, Orhun

    2006-10-01

    Wear of ultra-high-molecular-weight polyethylene (UHMWPE) contributes to debris that can lead to periprosthetic osteolysis in total hip arthroplasty. Irradiation not only decreases wear of UHMWPE but also generates residual free radicals that can oxidize the UHMWPE in the long term. Melting or annealing is used to quench the free radicals. Melting is more effective than annealing. We hypothesized that the postirradiation annealed UHMWPE components would oxidize in vivo and that postirradiation melted ones would not. We analyzed surgical explants of UHMWPE acetabular liners. The irradiated and annealed explants showed embrittlement, oxidation, and an increase in crystallinity. The irradiated and melted UHMWPE explants showed no oxidation, no increase in crystallinity, and no embrittlement. To prevent long-term chemical changes in highly cross-linked UHMWPE components, the residual free radicals must be stabilized after irradiation, preferably by melting and not annealing. PMID:17027543

  17. Effect of palady and cup feeding on premature neonates’ weight gain and reaching full oral feeding time interval

    PubMed Central

    Marofi, Maryam; Abedini, Fatemeh; Mohammadizadeh, Majid; Talakoub, Sedigheh

    2016-01-01

    Background: Premature neonates’ feeding is of great importance due to its effective role in their growth. These neonates should reach an independent oral nutrition stage before being discharged from the Neonatal Intensive care Unit. Therefore, the researcher decided to conduct a study on the effect of palady and cup feeding on premature neonates’ weight gain and their reaching full oral feeding time interval. Materials and Methods: This is a clinical trial with a quantitative design conducted on 69 premature infants (gestational age between 29 and 32 weeks) who were assigned to cup (n = 34) and palady (n = 35) feeding groups through random allocation. The first feeding was administrated either by cup or palady method in each shift within seven sequential days (total of 21 cup and palady feedings). Then, the rest of feeding was administrated by gavage. Results: Mean hospitalization time (cup = 39.01 and palady = 30.4; P < 0.001) and mean time interval to reach full oral feeding (cup = 33.7 and palady = 24.1; P < 0.001) were significantly lower in palady group compared to cup group. Mean weight changes of neonates 7 weeks after the intervention compared to those in the beginning of the intervention were significantly more in palady group compared to the cup group (cup = 146.7 and palady = 198.8; P < 0.001). Conclusions: The neonates in palady group reached full oral feeding earlier than those of cup group. Subjects’ weight gain was also higher in palady group compared to the cup group. Premature neonates with over 30 weeks of gestational age and physiological stability can be fed by palady. PMID:27095996

  18. Basic research for development of the beam profile monitor based on a Faraday cup array system

    NASA Astrophysics Data System (ADS)

    Park, Mook-Kwang

    2015-10-01

    The basic design used to develop a beam profile monitor based on a Faraday cup array (FCA), which has the advantages of high robustness, reliability, and long-term stability, along with the ability to measure the ion current over a wide dynamic range, was developed. The total system is divided into three parts: i.e., a faraday cup, measuring electronics, and a display program part. The FCA was considered to consist of a collimator, suppressor, insulator frame, and 64 (8 × 8 array) tiny Faraday cups (FC). An electronic circuit using a multiplexer was applied to effectively address many signal lines and the printed circuit board (PCB) was designed to be divided into three parts, i.e., an electrode PCB (ELEC PCB), capacitance PCB (CAP PCB), and control PCB (CON PCB).

  19. Optic Disc and Cup Segmentation from Color Fundus Photograph Using Graph Cut with Priors

    PubMed Central

    Zheng, Yuanjie; Stambolian, Dwight; O’Brien, Joan; Gee, James C.

    2014-01-01

    For automatic segmentation of optic disc and cup from color fundus photograph, we describe a fairly general energy function that can naturally fit into a global optimization framework with graph cut. Distinguished from most previous work, our energy function includes priors on the shape & location of disc & cup, the rim thickness and the geometric interaction of “disc contains cup”. These priors together with the effective optimization of graph cut enable our algorithm to generate reliable and robust solutions. Our approach is able to outperform several state-of-the-art segmentation methods, as shown by a set of experimental comparisons with manual delineations and a series of results of correlations with the assessments of a merchant-provided software from Optical Coherence Tomography (OCT) regarding several cup and disc parameters. PMID:24579126

  20. Optimization of lithography process for the fabrication of Micro-Faraday cup array

    NASA Astrophysics Data System (ADS)

    Arab, J. M.; Brahmankar, P. K.; Pawade, R. S.; Srivastava, A. K.

    2016-05-01

    Micro-faraday cup array detector (MFCAD) is used for the detection of charge of incoming ions in mass spectrometry. The optimization of complete lithography process for the fabrication of Micro-Faraday cup array detector structure in photoresist (AZ4903) on silicon substrate is reported in this work. An UV-LED based exposure system is designed for the transfer of micro-faraday cup structure on to the photoresist. The assembly consists of exposure system, collimating lens and mask/substrate holder. The fabrication process consists of coating of photoresist on Silicon substrate, designing and printing the photo mask and finally the UV lithography. These fabricated structures are characterized using optical microscope. The dimensions achieved are found to be similar as compared to the photo mask.

  1. Cultural change--empowerment at Sweetheart Cup Company, Inc., Bakery Division.

    PubMed

    Altomonte, W; Mooney, W; Sheldon, D H

    1999-08-01

    Sweetheart Cup Company always has been associated with fun products--fast food containers, straws, ballpark drink glasses, and maybe the most fun of all--ice cream cones! But making these products of pleasantry at times has not been as festive as it would seem. Sweetheart Cup Company has had its ups and downs in terms of many of the typical manufacturing measurements, but in 1994--under the direction of newly appointed Chief Operating Officer Bill McLaughlin--Sweetheart Cup Company embarked on a new mission. This time everyone would be involved, from headquarters staff in Owings Mills to the fourth-floor oven area workers in the Dallas bakery. The new process goal, "Business Excellence," as we called it, was really an implementation of Class A ERP/MRP II. PMID:10662450

  2. Influence of participation in a cup-stacking unit on timing tasks.

    PubMed

    Hart, Melanie A; Smith, Lori A; DeChant, Ann

    2005-12-01

    Cup stacking is a relatively new activity which has been promoted at conferences for physical educators as having many direct and indirect benefits, such as improved quickness. This study examined the influence of a cup-stacking instructional unit on reaction and anticipation times of 69 children in Grades 2 and 4. Within each grade participants were assigned to an experimental or a control group. The former received a 3-wk. instructional unit following the lesson plans provided by the promoters of cup stacking. The control groups received a standard physical education curriculum. Analysis indicated no significant differences in reaction and anticipation times between the groups before and after practicing the instructional unit. PMID:16491691

  3. Factors influencing evaporation from sample cups and assessment of their effect on analytical error.

    PubMed

    Burtis, C A; Begovich, J M; Watson, J S

    1975-12-01

    We studied sample evaporation and its effect on analytical error. Several factors influencing evaporative loss have been identified and measured: environmental, instrumental, and operational factors, and the chemical and physical properties of the sample and its container. Such losses from several different types of sample cups have been measured, either chemically or gravimetrically, and compared with those calculated by using a model that allows evaporative loss from a cup of known geometry to be predicted under various environmental conditions. We discuss some steps that may be taken to minimize evaporative loss and give an example to demonstrate that analytical error from this source can be decreased to a routine 1--2% or less by selecting a particular cup design. PMID:1192582

  4. Superpixel classification based optic disc and optic cup segmentation for glaucoma screening.

    PubMed

    Cheng, Jun; Liu, Jiang; Xu, Yanwu; Yin, Fengshou; Wong, Damon Wing Kee; Tan, Ngan-Meng; Tao, Dacheng; Cheng, Ching-Yu; Aung, Tin; Wong, Tien Yin

    2013-06-01

    Glaucoma is a chronic eye disease that leads to vision loss. As it cannot be cured, detecting the disease in time is important. Current tests using intraocular pressure (IOP) are not sensitive enough for population based glaucoma screening. Optic nerve head assessment in retinal fundus images is both more promising and superior. This paper proposes optic disc and optic cup segmentation using superpixel classification for glaucoma screening. In optic disc segmentation, histograms, and center surround statistics are used to classify each superpixel as disc or non-disc. A self-assessment reliability score is computed to evaluate the quality of the automated optic disc segmentation. For optic cup segmentation, in addition to the histograms and center surround statistics, the location information is also included into the feature space to boost the performance. The proposed segmentation methods have been evaluated in a database of 650 images with optic disc and optic cup boundaries manually marked by trained professionals. Experimental results show an average overlapping error of 9.5% and 24.1% in optic disc and optic cup segmentation, respectively. The results also show an increase in overlapping error as the reliability score is reduced, which justifies the effectiveness of the self-assessment. The segmented optic disc and optic cup are then used to compute the cup to disc ratio for glaucoma screening. Our proposed method achieves areas under curve of 0.800 and 0.822 in two data sets, which is higher than other methods. The methods can be used for segmentation and glaucoma screening. The self-assessment will be used as an indicator of cases with large errors and enhance the clinical deployment of the automatic segmentation and screening. PMID:23434609

  5. Dykes, cups, saucers and sills: Analogue experiments on magma intrusion into brittle rocks

    NASA Astrophysics Data System (ADS)

    Mathieu, L.; van Wyk de Vries, B.; Holohan, Eoghan P.; Troll, Valentin R.

    2008-07-01

    Magma is transported in the crust by blade-like intrusions such as dykes, sills, saucers, and also collects in thicker laccoliths, lopoliths and plutons. Recently, the importance and great number of shallow (< 5 km) saucer-shaped intrusions has been recognized. Lopoliths and cup-shaped intrusions have also been reported in many geological contexts. Our field observations indicate that many intrusions, especially those emplaced into breccias or fractured rocks, have bulging, lobate margins and have shear faults at their bulbous terminations. Such features suggest that magma can propagate along a self-induced shear fault rather than a hydraulic tension-fracture. To investigate this we use analogue models to explore intrusion propagation in a brittle country rock. The models consist of the injection of analogue magma (honey or Golden syrup) in a granular material (sand or sieved ignimbrite) that is a good analogue for brittle or brecciated rocks. These models have the advantage (over other models that use gelatin) to well represent the properties of brittle materials by allowing both shear-faults and tension fractures to be produced at suitable stresses. In our experiments we mainly obtain vertical dykes and inverted-cone like structures that we call cup-shaped intrusions. Dykes bifurcate into cup-shaped intrusions at depths depending on their viscosity. All cup-shaped intrusions uplift a central block. By injecting against a vertical glass plate we obtain detailed observations of the intrusion propagation style. We observe that dykes commonly split and produce cup-shaped intrusions near the surface and that shear zone-related intrusions develop at the dyke tip. We conclude that many dykes propagate as a viscous indenter resulting from shear failure of host rock rather than tensional hydraulic fracturing of host rocks. The shear propagation model provides an explanation for the shape and formation of cup-shaped intrusions, saucer-sills and lopoliths.

  6. Balls, cups, and quasi-potentials: quantifying stability in stochastic systems.

    PubMed

    Nolting, Ben C; Abbott, Karen C

    2016-04-01

    When a system has more than one stable state, how can the stability of these states be compared? This deceptively simple question has important consequences for ecosystems, because systems with alternative stable states can undergo dramatic regime shifts. The probability, frequency, duration, and dynamics of these shifts will all depend on the relative stability of the stable states. Unfortunately, the concept of "stability" in ecology has suffered from substantial confusion and this is particularly problematic for systems where stochastic perturbations can cause shifts between coexisting alternative stable states. A useful way to visualize stable states in stochastic systems is with a ball-in-cup-diagram, in which the state of the system is represented as the position of a ball rolling on a surface, and the random perturbations can push the ball from one basin of attraction to another. The surface is determined by a potential function, which provides a natural stability metric. Systems amenable to this representation, called gradient systems, are quite rare, however. As a result, the potential function is not widely used and other approaches based on linear stability analysis have become standard. Linear stability analysis is designed for local analysis of deterministic systems and, as we show, can produce a highly misleading picture of how the system will behave under continual, stochastic perturbations. In this paper, we show how the potential function can be generalized so that it can be applied broadly, employing a concept from stochastic analysis called the quasi-potential. Using three classic ecological models, we demonstrate that the quasi-potential provides a useful way to quantify stability in stochastic systems. We show that the quasi-potential framework helps clarify long-standing confusion about stability in stochastic ecological systems, and we argue that ecologists should adopt it as a practical tool for analyzing these systems. PMID:27220202

  7. Effects of the 2010 World Cup football tournament on emergency department assault attendances in England.

    PubMed

    Quigg, Zara; Hughes, Karen; Bellis, Mark A

    2013-06-01

    We explore the impact of the 2010 World Cup, held in South Africa, on levels of assault attendances to 15 emergency departments in England. The majority (70.1%) of assault attendees during the 2010 World Cup was male and aged 18-34 years (52.5%). Assault attendances increased by 37.5% on the days that England played (P 001). Preparation for major sporting events in non-host countries should include violence prevention activity. Emergency department data can be used to identify violence associated with such events and thus inform both the targeting of prevention efforts and assessments of their effectiveness. PMID:22874732

  8. Cup-Drawing Behavior of High-Strength Steel Sheets Containing Different Volume Fractions of Martensite

    SciTech Connect

    Choi, Shi-Hoon; Kim, Dae-Wan; Yang, Hoe-Seok; Han, Seong-Ho; Yoon, Jeong Whan

    2010-06-15

    Planar anisotropy and cup-drawing behavior were investigated for high-strength steel sheets containing different volume fractions of martensite. Macrotexture analysis using XRD was conducted to capture the effect of crystallographic orientation on the planar anisotropy of high-strength steel sheets. A phenomenological yield function, Yld96, which accounts for the anisotropy of yield stress and r-values, was implemented into ABAQUS using the user subroutine UMAT. Cup drawing of high-strength steel sheets was simulated using the FEM code. The profiles of earing and thickness strain were compared with the experimentally measured results.

  9. Cup-Drawing Behavior of High-Strength Steel Sheets Containing Different Volume Fractions of Martensite

    NASA Astrophysics Data System (ADS)

    Choi, Shi-Hoon; Kim, Dae-Wan; Yang, Hoe-Seok; Han, Seong-Ho; Yoon, Jeong Whan

    2010-06-01

    Planar anisotropy and cup-drawing behavior were investigated for high-strength steel sheets containing different volume fractions of martensite. Macrotexture analysis using XRD was conducted to capture the effect of crystallographic orientation on the planar anisotropy of high-strength steel sheets. A phenomenological yield function, Yld96, which accounts for the anisotropy of yield stress and r-values, was implemented into ABAQUS using the user subroutine UMAT. Cup drawing of high-strength steel sheets was simulated using the FEM code. The profiles of earing and thickness strain were compared with the experimentally measured results.

  10. Addendum: Safety Standards for Gua sha (press-stroking) and Ba guan (cupping).

    PubMed

    Nielsen, Arya; Kligler, Ben; Koll, Brian S

    2014-06-01

    Our previous article Safety Standards for Gua sha (press-stroking) and Baguan (cupping) discussed the risk of transfer of blood-borne pathogens with Gua sha and Ba guan, identified Gua sha and Ba guan 'instrument criticality' as semi-critical and offered recommendations for safe practice based on hospital disinfection standards. Based on the article's feedback, we feel the need to clarify that Gua sha and Ba guan instruments, if intended for reuse, must undergo high level disinfection (HLD) or, in the case of 'wet-cupping', sterilization. We update our recommendations to be amenable to both private practice and education settings. PMID:24906583

  11. Stripline fast faraday cup for measuring GHz structure of ion beams

    DOEpatents

    Bogaty, John M.

    1992-01-01

    The Stripline Fast Faraday Cup is a device which is used to quantitatively and qualitatively measure gigahertz time structure characteristics of ion beams with energies up to at least 30 Mev per nucleon. A stripline geometry is employed in conjunction with an electrostatic screen and a Faraday cup to provide for analysis of the structural characteristics of an ion beam. The stripline geometry allows for a large reduction in the size of the instrument while the electrostatic screen permits measurements of the properties associated with low speed ion beams.

  12. NCI Takes Back the Defelice Cup at Ninth Annual Golf Tournament | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer After being down by a point in the morning, NCI reclaimed the Defelice Cup trophy from Leidos Biomedical Research, with a final score of 12 ½ to 11 ½, at the ninth annual Ronald H. Defelice Golf Tournament, held Oct. 13. “The tightest matches in the nine-year history of this cup competition resulted in a narrow victory for NCI and allowed NCI to take a 5–4 victory total,” said Denny Dougherty, one of the team captains for Leidos Biomed and a retired senior subcontracts advisor at what was formerly SAIC-Frederick.

  13. 'Our struggles are bigger than the World Cup': civic activism, state-society relations and the socio-political legacies of the 2010 FIFA World Cup.

    PubMed

    Cornelissen, Scarlett

    2012-06-01

    South Africa's hosting of the 2010 FIFA World Cup saw a large number of public demonstrations, strikes and other forms of civic campaigning. World Cup activism was both preceded and followed by extensive and intensifying public unrest and industrial action that in the period before the tournament, threatened to derail the event. This paper assesses the motivations, forms and implications of the activism during South Africa's staging of the FIFA finals and interprets them against the larger context of shifting state-society relations in the country. There are two purposes to the analysis. First, to explore the underlying internal social forces that gave shape to the protests at the time, and the possible influence of the exogenous politics of mega-event social mobilization. Second, the implications and outcomes of these dynamics for longer term socio-political processes in the country are considered. The activism displayed many of the features of the politics of contestation of sport mega-events today. Importantly, however, the activism stemmed from a particular systemic dynamic and reflected changing relations in the post-apartheid political community. Therefore, while the World Cup was used as a strategic opportunity by many advocacy groups, it was one that rather fleetingly and ambivalently presented an additional platform to such groups in an otherwise on-going set of political battles. Rather than a strong case study of sport's transformative capacity, the civic campaigning during South Africa's World Cup demonstrates the way a sport mega-event can be used as a strategic entry point by civil society groups in their engagement with the state, although this can occur with greater or lesser success. PMID:22670650

  14. Design of a tapered stripline fast Faraday cup for measurements on heavy ion beams: problems and solutions

    SciTech Connect

    Marcellini, F.; Poggi, M.

    1998-12-10

    The design of a tapered stripline fast Faraday cup (TSFFC) to perform the impedance matching between the fast cup itself and the signal line (connector, cable, and amplifier) is reported here. The frequency response of the TSFFC as a high-pass filter is analyzed from a theoretical point of view and some solutions to achieve a broadband response are given.

  15. Demonstrating the Effects of Processing on the Structure and Physical Properties of Plastic Using Disposable PETE Cups

    ERIC Educational Resources Information Center

    Erk, Kendra A.; Rhein, Morgan; Krafcik, Matthew J.; Ydstie, Sophie

    2015-01-01

    An educational activity is described in which the structure and physical properties of disposable plastic cups were directly related to the method of processing. The mechanical properties of specimens cut from the walls of poly(ethylene terephthalate) (PETE) cups, oriented parallel and perpendicular to the thermoforming direction, were measured in…

  16. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    PubMed

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. PMID:26528936

  17. An extended posterior approach to the hip and pelvis for complex acetabular reconstruction that preserves the gluteal muscles and their neurovascular supply.

    PubMed

    Solomon, L B; Hofstaetter, J G; Bolt, M J; Howie, D W

    2014-01-01

    We investigated the detailed anatomy of the gluteus maximus, gluteus medius and gluteus minimus and their neurovascular supply in 22 hips in 11 embalmed adult Caucasian human cadavers. This led to the development of a surgical technique for an extended posterior approach to the hip and pelvis that exposes the supra-acetabular ilium and preserves the glutei during revision hip surgery. Proximal to distal mobilisation of the gluteus medius from the posterior gluteal line permits exposure and mobilisation of the superior gluteal neurovascular bundle between the sciatic notch and the entrance to the gluteus medius, enabling a wider exposure of the supra-acetabular ilium. This technique was subsequently used in nine patients undergoing revision total hip replacement involving the reconstruction of nine Paprosky 3B acetabular defects, five of which had pelvic discontinuity. Intra-operative electromyography showed that the innervation of the gluteal muscles was not affected by surgery. Clinical follow-up demonstrated good hip abduction function in all patients. These results were compared with those of a matched cohort treated through a Kocher-Langenbeck approach. Our modified approach maximises the exposure of the ilium above the sciatic notch while protecting the gluteal muscles and their neurovascular bundle. PMID:24395310

  18. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  19. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  20. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  1. 78 FR 57482 - Safety Zone; America's Cup Aerobatic Box, San Francisco Bay, San Francisco, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... San Francisco, CA in support of 2013 America's Cup air shows. These safety zones are established to provide a clear area on the water for pilots to initiate maneuvers and also provide for the safety of... rule is effective as to persons with actual notice starting September 6, 2013. This rule is...

  2. The Empty Cup: "Teaching for Understanding" at 21st Century Edward Waters College. Occasional Paper #6

    ERIC Educational Resources Information Center

    Fluellen, Jerry E., Jr.

    2008-01-01

    What happens in a final project that fosters teaching for understanding? That inquiry calls to mind the Taoist belief that emptiness makes a cup useful. In the context of this paper, the inquiry organizes a narrative about how teaching for understanding surfaced in a "Theories of Learning" course at Edward Waters College. At a deeper level, the…

  3. Using RoboCup in University-Level Computer Science Education

    ERIC Educational Resources Information Center

    Sklar, Elizabeth; Parsons, Simon; Stone, Peter

    2004-01-01

    In the education literature, team-based projects have proven to be an effective pedagogical methodology. We have been using "RoboCup" challenges as the basis for class projects in undergraduate and masters level courses. This article discusses several independent efforts in this direction and presents our work in the development of shared…

  4. 75 FR 29889 - Special Local Regulation for Marine Event; 2010 International Cup Regatta, Pasquotank River...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... International Cup Regatta, Pasquotank River, Elizabeth City, NC AGENCY: Coast Guard, DHS. ACTION: Temporary... action is intended to restrict vessel traffic in a portion of the Pasquotank River, near Elizabeth City... races on the waters of the Pasquotank River adjacent to Elizabeth City, North Carolina. The event...

  5. Eighth Grade Students' Representations of Linear Equations Based on a Cups and Tiles Model

    ERIC Educational Resources Information Center

    Caglayan, Gunhan; Olive, John

    2010-01-01

    This study examines eighth grade students' use of a representational metaphor (cups and tiles) for writing and solving equations in one unknown. Within this study, we focused on the obstacles and difficulties that students experienced when using this metaphor, with particular emphasis on the operations that can be meaningfully represented through…

  6. Identification and Correction of Mechanisms Underlying Inherited Blindness in Human iPSC-Derived Optic Cups.

    PubMed

    Parfitt, David A; Lane, Amelia; Ramsden, Conor M; Carr, Amanda-Jayne F; Munro, Peter M; Jovanovic, Katarina; Schwarz, Nele; Kanuga, Naheed; Muthiah, Manickam N; Hull, Sarah; Gallo, Jean-Marc; da Cruz, Lyndon; Moore, Anthony T; Hardcastle, Alison J; Coffey, Peter J; Cheetham, Michael E

    2016-06-01

    Leber congenital amaurosis (LCA) is an inherited retinal dystrophy that causes childhood blindness. Photoreceptors are especially sensitive to an intronic mutation in the cilia-related gene CEP290, which causes missplicing and premature termination, but the basis of this sensitivity is unclear. Here, we generated differentiated photoreceptors in three-dimensional optic cups and retinal pigment epithelium (RPE) from iPSCs with this common CEP290 mutation to investigate disease mechanisms and evaluate candidate therapies. iPSCs differentiated normally into RPE and optic cups, despite abnormal CEP290 splicing and cilia defects. The highest levels of aberrant splicing and cilia defects were observed in optic cups, explaining the retinal-specific manifestation of this CEP290 mutation. Treating optic cups with an antisense morpholino effectively blocked aberrant splicing and restored expression of full-length CEP290, restoring normal cilia-based protein trafficking. These results provide a mechanistic understanding of the retina-specific phenotypes in CEP290 LCA patients and potential strategies for therapeutic intervention. PMID:27151457

  7. Technology and Teaching: Searching under Cups for Clues about Memory--An Online Demonstration

    ERIC Educational Resources Information Center

    Kahan, Todd A.; Mathis, Katherine M.

    2007-01-01

    An online demonstration, designed to enhance comprehension of Sternberg's (1966) short-term memory scanning task, involved rapidly searching under virtual cups for a ball. We randomly assigned students to 1 of 3 groups, all of whom read the same textbook description of Sternberg's work: A demonstration group used 3 search methods to look for balls…

  8. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  9. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  10. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  11. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  12. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver...

  13. Iatrogenic artefacts attributable to traditional cupping therapy in a shotgun fatality.

    PubMed

    Cavlak, Mehmet; Özkök, Alper; Sarı, Serhat; Dursun, Ahmet; Akar, Taner; Karapirli, Mustafa; Demirel, Birol

    2015-10-01

    Cupping is a traditional treatment method that has been used for thousands of years to diminish pain, restore appetite and improve digestion, remove tendency to faint or remove 'bad blood' from the body. The suction of the cup is created by fire or mechanical devices. This procedure may result in circular erythema, petechiae, purpura, ecchymosis, burns and may be mistaken for trauma-related ecchymosis or livor mortis. Forty-year-old male was died by shotgun injuries in the same day of the wounding. Circular ecchymoses were observed on the forehead, within the scalp of occipital region, the back of the neck, and on the back. They were defined as ecchymoses in the first examination made by a general practitioner. In the external examination during the legal autopsy superficial incisions were observed on the circular ecchymoses. The shape, localization and color of and the characteristics of incisions on the circular lesions were concluded to be caused by the dry cupping therapy and wet cupping therapy procedures. These lesions and their formation mechanisms should be well-known by the forensic medical examiners and the other medical personnel involved in the forensic medical examination. PMID:26344454

  14. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  15. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold...

  16. Simultaneous GC-MS determination of seven phthalates in total and migrated portions of paper cups.

    PubMed

    Park, Yu Na; Choi, Min Sun; Rehman, Shaheed Ur; Gye, Myung Chan; Yoo, Hye Hyun

    2016-05-01

    Phthalate acid esters are widely used as plasticizers to impart plastic flexibility in various industrial applications. In this study, the content of seven phthalates, dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), di-(2-ethylhexyl) adipate (DEHA), di-2-ethylhexyl phthalate (DEHP), di-n-octyl phthalate (DNOP), di-isononyl phthalate (DINP), and di-isodecyl phthalate (DIDP) were determined in paper cups using gas chromatography-mass spectrometry (GC-MS). In addition, the potential migration of these seven phthalates from paper cups into various food stimulants under different conditions was evaluated. The levels of DBP, DEHA, DEHP, and DNOP were in the ranges of 0.07-3.14, 0.16-42.69, 0.45-58.56, and 0.3-2.4 mg/kg, respectively. Meanwhile, BBP, DINP, and DIDP were not detected in most of the tested samples. In the migration test, DEHA was released to 50 % ethanol and n-heptane in a time-dependent manner and the maximum migration levels were 65.62 ± 3.61 and 95.56 ± 19.76 μg/L, respectively. The release of other phthalates was very low or negligible. These results demonstrated that paper cups are not a significant source of phthalate exposure; however, DEHA could be released from paper cups into alcoholic beverages or oily liquid beverages in the human diet. PMID:27053047

  17. ESCRT-III drives the final stages of CUPS maturation for unconventional protein secretion.

    PubMed

    Curwin, Amy J; Brouwers, Nathalie; Alonso Y Adell, Manuel; Teis, David; Turacchio, Gabriele; Parashuraman, Seetharaman; Ronchi, Paolo; Malhotra, Vivek

    2016-01-01

    The unconventional secretory pathway exports proteins that bypass the endoplasmic reticulum. In Saccharomyces cerevisiae, conditions that trigger Acb1 secretion via this pathway generate a Grh1 containing compartment composed of vesicles and tubules surrounded by a cup-shaped membrane and collectively called CUPS. Here we report a quantitative assay for Acb1 secretion that reveals requirements for ESCRT-I, -II, and -III but, surprisingly, without the involvement of the Vps4 AAA-ATPase. The major ESCRT-III subunit Snf7 localizes transiently to CUPS and this was accelerated in vps4Δ cells, correlating with increased Acb1 secretion. Microscopic analysis suggests that, instead of forming intraluminal vesicles with the help of Vps4, ESCRT-III/Snf7 promotes direct engulfment of preexisting Grh1 containing vesicles and tubules into a saccule to generate a mature Acb1 containing compartment. This novel multivesicular / multilamellar compartment, we suggest represents the stable secretory form of CUPS that is competent for the release of Acb1 to cells exterior. PMID:27115345

  18. Spinal Epidural Hematoma Following Cupping Glass Treatment in an Infant With Hemophilia A.

    PubMed

    Fruchtman, Yariv; Dardik, Rima; Barg, Assaf Arie; Livnat, Tami; Feldman, Zeev; Rubinstein, Marina; Grinberg, Gahl; Rosenberg, Nurit; Kenet, Gili

    2016-06-01

    A 6 months old infant, diagnosed with a rare mutation causing severe hemophilia A, presented with spinal epidural hematoma. Parents later admitted the infant had glass cupping therapy performed within 2 weeks of the onset of symptoms. The rare mutation, rare bleeding complication, and the eventual course of therapy applied in this case will be discussed in our case report. PMID:26844816

  19. 78 FR 21260 - Safety Zone; Lubbers Cup Regatta; Spring Lake, MI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-10

    .... SUPPLEMENTARY INFORMATION: Table of Acronyms DHS Department of Homeland Security FR Federal Register NPRM Notice... SECURITY Coast Guard 33 CFR PART 165 RIN 1625-AA00 Safety Zone; Lubbers Cup Regatta; Spring Lake, MI AGENCY... safety zone on Spring Lake in Spring Lake, Michigan. This safety zone is intended to restrict...

  20. The Empty Cup (Power Teaching in a Digital Age). Occasional Paper #9

    ERIC Educational Resources Information Center

    Fluellen, Jerry E., Jr.

    2011-01-01

    What might count as a world class, national public education system in 2020? That empty cup took the floor at the 2010 Future of Learning (FoL) Summer Institute at Harvard University. It traveled from Longfellow Hall's lecture room on Appian Way to several learning groups scattered around campus. Though not deliberately created to think about…