Science.gov

Sample records for acetabular fractures treated

  1. Pelvic and acetabular fractures

    SciTech Connect

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair.

  2. Inguinal Abnormalities in Male Patients with Acetabular Fractures Treated Using an Ilioinguinal Exposure

    PubMed Central

    Firoozabadi, Reza; Stafford, Paul; Routt, Milton

    2015-01-01

    Background: Surgeons performing an ilioinguinal exposure for acetabular fracture surgery need to be aware of aberrant findings such as inguinal hernias and spermatic cord lesions. The purpose of this study is to report these occurrences in a clinical series of adult males undergoing acetabular fracture fixation and a series of adult male cadavers. The secondary aim is to characterize these abnormalities to aid surgeons in detecting these abnormalities preoperatively and coordinating a surgical plan with a general surgeon. Methods: Clinical study- Retrospective review of treated acetabular fractures through an ilioinguinal approach. Incidence of inguinal canal and spermatic cord abnormalities requiring general surgery consultation were identified. Corresponding CT scans were reviewed and radiographic characteristics of the spermatic cord abnormalities and/or hernias were noted. Cadaveric study- 18 male cadavers dissected bilaterally using an ilioinguinal exposure. The inguinal canal and the contents of the spermatic cord were identified and characterized. Results: Clinical Study- 5.7% (5/87) of patients had spermatic cord lesion and/or inguinal hernia requiring general surgical intervention. Preoperative pelvic CT scan review identified abnormalities noted intraoperatively in four of the five patients. Cord lipomas visualized as enlargements of the spermatic cord with homogeneous density. Hernias visualized as enlarged spermatic cords with heterogeneous density. Cadaver Study- 31% (11/36) of cadavers studied had spermatic cord and/or inguinal canal abnormalities. Average cord diameter in those with abnormalities was 24.9 mm (15-28) compared to 16 mm (11-22) in normal cords, which was statistically significant. Discussion: The clinical and cadaveric findings emphasize the importance of understanding inguinal abnormalities and the value of detecting them preoperatively. The preoperative pelvic CT scans were highly sensitive in detecting inguinal abnormalities. PMID

  3. Changes in the treatment of acetabular fractures over 15 years: Analysis of 1266 cases treated by the German Pelvic Multicentre Study Group (DAO/DGU).

    PubMed

    Ochs, Björn Gunnar; Marintschev, Ivan; Hoyer, Heike; Rolauffs, Bernd; Culemann, Ulf; Pohlemann, Tim; Stuby, Fabian Maria

    2010-08-01

    Epidemiological, clinical and radiological data of 1266 patients with a unilateral acetabular fracture of up to 29 hospitals was reviewed. Three time periods, 1991-1993 (Registry I; n=359), 1998-2000 (Registry II; n=503), and 2005-2006 (Registry III; n=404) were compared with regard to injury pattern and severity, fracture type, and chosen nonoperative vs. operative treatment to elucidate changes over time in the treatment of acetabular fractures. In the operatively treated group, time to operation, surgical approach, fracture fixation implants and fracture reduction quality were examined. 641 (50.6%) patients with isolated acetabular fractures, 410 (32.4%) multiple injured and 215 (17.0%) polytrauma patients with 642 (50.7%) simple and 624 (49.3%) associated acetabular fractures were evaluated. In the time period from 1991 to 2006, the rate of operative treatments increased nationwide to 77% (rho<0.001). The distribution of fracture types involving the anterior and posterior wall changed with age (rho<0.001). Across all registries, 583 (68.0%) operations were performed within 7 days, 212 (24.7%) operations between 7 and 14 days and 54 (6.3%) operations were performed later than 14 days after injury. An anatomical reduction (0-1mm displacement) was achieved in 551 (64%) acetabular fractures. The obtained reduction quality did not correlate with time to operation, was lower in associated than in simple fracture types, and also lower in patients with isolated acetabular fractures than in polytrauma patients. Most importantly, the fracture reduction quality did not improve over time despite a higher frequency of surgical interventions. The Kocher-Langenbeck approach was preferred in the nineties in nearly three quarters of all operative procedures. Currently, the Kocher-Langenbeck and the ilioinguinal approaches are used equally often. The fracture fixation did not change over time and is achieved in 51% with plates in combination with single screws. This multisurgeon

  4. Arthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note.

    PubMed

    Park, Jin Young; Chung, Woo Chull; Kim, Che Keun; Huh, Soon Ho; Kim, Se Jin; Jung, Bo Hyun

    2016-06-01

    Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report our case with technical note. PMID:27536654

  5. Arthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note

    PubMed Central

    Park, Jin young; Kim, Che Keun; Huh, Soon Ho; Kim, Se Jin; Jung, Bo Hyun

    2016-01-01

    Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report our case with technical note. PMID:27536654

  6. Traumatic Periprosthetic Acetabular Fracture Treated with One-Stage Exchange and Bone Reconstruction Using a Synthetic Bone Graft Substitute

    PubMed Central

    2016-01-01

    A case of a traumatic periprosthetic acetabular fracture in an elderly patient, which was treated by one-stage hip exchange with implantation of an antiprotrusio cage and reconstruction of the acetabular bone loss with an injectable calcium sulphate/hydroxyapatite bone graft substitute, is reported. The paste-like bone graft substitute was injected through the holes of the antiprotrusio cage. After a setting time of 15 minutes, a low-profile cup was cemented onto the cage using polymethylmethacrylate and a new stem was inserted. The patient was encouraged to ambulate three days postoperatively weight-bearing as tolerated. At the one-year follow-up visit the patient was ambulatory and full weight-bearing without any walking aids. The follow-up radiographs demonstrated stable position and articulation of the revision hip arthroplasty with no signs of loosening of the antiprotrusio cage. However, the most interesting finding was that the bone graft substitute had remodelled to a great extent into bone. This calcium sulphate/hydroxyapatite composite shows high osteoconductive potential and can be used to regenerate bone stock in revision arthroplasty. PMID:27446621

  7. Traumatic Periprosthetic Acetabular Fracture Treated with One-Stage Exchange and Bone Reconstruction Using a Synthetic Bone Graft Substitute.

    PubMed

    Svacina, Jan

    2016-01-01

    A case of a traumatic periprosthetic acetabular fracture in an elderly patient, which was treated by one-stage hip exchange with implantation of an antiprotrusio cage and reconstruction of the acetabular bone loss with an injectable calcium sulphate/hydroxyapatite bone graft substitute, is reported. The paste-like bone graft substitute was injected through the holes of the antiprotrusio cage. After a setting time of 15 minutes, a low-profile cup was cemented onto the cage using polymethylmethacrylate and a new stem was inserted. The patient was encouraged to ambulate three days postoperatively weight-bearing as tolerated. At the one-year follow-up visit the patient was ambulatory and full weight-bearing without any walking aids. The follow-up radiographs demonstrated stable position and articulation of the revision hip arthroplasty with no signs of loosening of the antiprotrusio cage. However, the most interesting finding was that the bone graft substitute had remodelled to a great extent into bone. This calcium sulphate/hydroxyapatite composite shows high osteoconductive potential and can be used to regenerate bone stock in revision arthroplasty. PMID:27446621

  8. An occult acetabular fracture preceding a femoral neck fracture.

    PubMed

    Lasanianos, Nikolaos; Kanakaris, Nikolaos; Giannoudis, Peter V

    2009-08-01

    This article describes the case of a 69-year-old patient with an occult acetabular fracture complicated by an ipsilateral femoral neck fracture occurring within 2 months. The acetabular fracture remained undiagnosed at examination due to insufficient clinical and radiographic data interpretation. The patient was assured of early mobilization that led to a fall and subsequent hip fracture. We focus on the potential reasons for the nondiagnosis of the acetabular fracture. Acetabular fractures in the elderly may occur after low-energy injuries. The lack of history of violent injury may lead to an incorrect diagnosis. Plain anteroposterior (AP) pelvis radiographs alone may prove an insufficient tool, especially in the hands of inexperienced personnel. As is characteristic, a retrospective review of the AP pelvis radiograph obtained after the first fall in our case revealed the undisplaced fracture of the anterior column that was missed initially. Combined fractures of the hip and the acetabulum are rarely described in the literature and are usually addressed by total hip arthroplasty (THA) alone. Similar fracture patterns that develop in 2 stages (2 injuries), as the 1 presented herein, are even more rare. The uniqueness of this combined fracture required a unique surgical treatment. The senior surgeon (P.V.G.) addressed the acetabular fracture separately to graft the anterior column fracture and facilitate union, as it was already 8 weeks old and the second fall had generated a further gap between the fragments. Stable fixation was felt appropriate prior to the THA. Thus, a double surgical approach was used. Six weeks postoperatively, the patient was able to perform full weight-bearing mobilization without an antalgic gait pattern. At 6-month follow-up, radiographs showed the metalwork to be in place with no displacement, and the fracture had progressed to union. PMID:19708620

  9. The submuscular sliding plate technique for acetabular posterior wall fractures extending to the acetabular roof.

    PubMed

    Kim, J J; Kim, J W; Oh, H K

    2014-12-01

    There is extension of the Kocher-Langenbeck approach using trochanteric osteotomy for posterior wall fracture extending to acetabular roof, but it exposes to complications such as nonunion, breakage, and heterotopic ossification. The current study introduces a submuscular sliding plate technique. We retrospectively analyzed 13 patients treated with this technique. It is based on conventional method for posterior wall fracture. After reduction of roof fragment with direct visualization, a pre-contoured plate was passed through a submuscular tunnel under the gluteus medius and minimus. A small split incision was performed on the muscles, and screws were inserted with a triple trocar complex safely under fluoroscopic imaging. All patients had fracture union without complications. X-rays results showed anatomical reduction in 10 cases and imperfect reduction in 3 cases. Our results were satisfactory, particularly without heterotopic ossifications despite no prophylactic regimen of NSAID was applied and no neurological complications, so we believe that this technique is a good option for posterior wall fractures extending to the acetabular roof. PMID:25453921

  10. Management of an Open Acetabular Fracture in a Skeletally Immature Patient

    PubMed Central

    Clutter, Sarah Y; Morgan, Steven J; Erickson, Mark; Smith, Wade R; Stahel, Philip F

    2007-01-01

    Background: Open acetabular fractures in children are rare, but potentially devastating injuries. Secondary to the low incidence, there is an apparent lack of reports on appropriate management strategies for open pediatric acetabular fractures in the literature. Methods: Description of a case study. Results: A 3 years and ten months-old girl was ejected as a passenger from an all terrain vehicle. She sustained a displaced, grade IIIA open left anterior column acetabular fracture. The injury was treated by extending the open wound to a formal first window of the ilioinguinal approach. After surgical debridement, the anterior column was reduced anatomically and fixed by two lag screws which avoided the tri-radiate cartilage. A vaginal laceration was debrided and repaired. The patient was treated in a spica cast without weight bearing on the left lower extremity for 8 weeks. No perioperative complications occurred. The acetabular fracture healed in an anatomic position within 8 weeks. To avoid premature closure of the tri-radiate cartilage, the patient underwent a physeal bar resection at one year after injury. At two-year follow up, she was walking and running without pain and had a free range of motion of her left hip. Conclusions: Operative management should represent the therapy of choice for open, displaced pediatric acetabular fractures. After fracture healing, a scheduled physeal bar resection may be required for injuries which involve the tri-radiate cartilage. PMID:19461903

  11. [Acetabular fractures in the elderly. Outcome of open reduction and internal fixation].

    PubMed

    Tosounidis, G; Culemann, U; Bauer, M; Holstein, J H; Garcia, P; Kurowski, R; Pizanis, A; Aghayev, E; Pohlemann, T

    2011-08-01

    The aim of this study was to analyze the clinical outcome and incidence of hip arthritis in elderly patients with acetabular fractures. Because of poor bone quality in the elderly, even a low-energy trauma may lead to an acetabular fracture. An anatomical reconstruction of the acetabulum is necessary to achieve sufficient stability also for a potential hip arthroplasty. So far, there is very limited information on the outcome of acetabular fractures in the elderly. During a period of 6 years (2001-2006), 48 patients older than 60 years were admitted to our department with an acetabular fracture. Thirty-nine patients were treated operatively and nine patients non-operatively. Twenty-nine operatively treated patients were followed up. Nineteen of them were assessed using EQ-5D, SF-12 and Merle d'Aubigné questionnaires in addition to their clinical examination. Ten other surgical patients were only examined using the questionnaires. Of the 29 patients that were followed up, 5 underwent total hip arthroplasty due to secondary post-traumatic hip arthritis after open reduction and internal fixation (ORIF). The range of motion of the operated hip was comparable to that of the non-operated contralateral side. However, the internal rotation was found to be slightly decreased at the operated side when compared to the non-operated contralateral side. Merle d'Aubigné score and physical and mental SF-12 score components as well as quality of life were better in patients treated with ORIF compared to those patients that were treated by secondary hip arthroplasty. Regarding the different treatment strategies (ORIF vs primary hip arthroplasty vs non-operative treatment) of acetabular fractures in the elderly, data from the literature are conflicting. Our results indicate that ORIF represents a good treatment option for acetabular fractures in the elderly. In patients that did not develop secondary hip arthritis, a good clinical outcome and quality of life was documented. PMID

  12. The effect of incisional negative pressure therapy on wound complications after acetabular fracture surgery.

    PubMed

    Reddix, Robert N; Leng, Xiaoyan Iris'; Woodall, James; Jackson, Benjamin; Dedmond, Barnaby; Webb, Lawrence X

    2010-01-01

    The purpose of the study was to determine if the use of incisional negative pressure therapy affected the rate of wound complications after acetabular fracture surgery. Between August 1996 to April 2005, 301 patients were found to have had an operatively treated acetabular fracture. There were 235 patients who had placement of incisional vacuum-assisted closure (VAC) who had three (1.27%) deep wound infections and one (0.426%) wound dehiscence. There were 66 consecutive patients who were available in the 5 years preceding the usage of the incisional VAC who had four (6.06%) deep wound infections and two (3.03%) wound dehiscences. This is less than the published infection rate of 4% for patients undergoing operative treatment of acetabular fractures and less than the authors' rate of 6.15% in the time period before the use of the incisional negative pressure wound therapy (p=.0414). The use of incisional negative pressure wound therapy significantly decreases perioperative wound complications after acetabular fracture surgery. PMID:20727304

  13. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    SciTech Connect

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion.

  14. Stress fracture in acetabular roof due to motocross: case report.

    PubMed

    de Paiva Luciano, Alexandre; Filho, Nelson Franco

    2016-01-01

    One of the first steps to be taken in order to reduce sports injuries such as stress fractures is to have in-depth knowledge of the nature and extent of these pathological conditions. We present a case report of a stress fracture of the acetabular roof caused through motocross. This type of case is considered rare in the literature. The description of the clinical case is as follows. The patient was a 27-year-old male who started to have medical follow-up because of uncharacteristic pain in his left hip, which was concentrated mainly in the inguinal region of the left hip during motocross practice. After clinical investigation and complementary tests, he was diagnosed with a stress fracture of the acetabular roof. PMID:27274494

  15. Acute polyethylene fracture in an uncemented acetabular cup

    PubMed Central

    Gross, Allan E.; Dust, William N.

    1997-01-01

    The smaller acetabular components used in total hip replacement may have a polyethylene liner that is too thin, resulting in higher polyethylene stress and an increased potential for wear. The authors present a case that highlights the problem of acute polyethylene fracture. To compensate for the thinness of the polyethylene, the authors recommend the use of a smaller head size to allow polyethylene thickness of at least 8 mm. PMID:9267302

  16. Spontaneous Acetabular Periprosthetic Fracture in a Patient Continuously Having Zoledronic Acid

    PubMed Central

    Tantavisut, Saran; Thanakit, Voranuch; Ngarmukos, Srihatach; Wilairatana, Vajara; Wangroongsub, Yongsak

    2014-01-01

    Zoledronic acid has been used for prevention of osteolytic and osteoblastic bone metastasis. This case report illustrates an undesirable consequence from prolonged usage of zoledronic acid in bone metastasis prevention. Periprosthetic acetabular fracture in a patient treated with zoledronic acid for 7 years was reported. The clinical presentation, radiographic and pathological results were described. This is a rare complication after total hip arthroplasty which should not be ignored especially in patients who received long term bisphosphonate. PMID:25177464

  17. Surgical dislocation of the hip for the fixation of acetabular fractures.

    PubMed

    Tannast, M; Krüger, A; Mack, P W; Powell, J N; Hosalkar, H S; Siebenrock, K A

    2010-06-01

    Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis. PMID:20513883

  18. Acetabular fractures: what radiologists should know and how 3D CT can aid classification.

    PubMed

    Scheinfeld, Meir H; Dym, Akiva A; Spektor, Michael; Avery, Laura L; Dym, R Joshua; Amanatullah, Derek F

    2015-01-01

    Correct recognition, description, and classification of acetabular fractures is essential for efficient patient triage and treatment. Acetabular fractures may result from high-energy trauma or low-energy trauma in the elderly. The most widely used acetabular fracture classification system among radiologists and orthopedic surgeons is the system of Judet and Letournel, which includes five elementary (or elemental) and five associated fractures. The elementary fractures are anterior wall, posterior wall, anterior column, posterior column, and transverse. The associated fractures are all combinations or partial combinations of the elementary fractures and include transverse with posterior wall, T-shaped, associated both column, anterior column or wall with posterior hemitransverse, and posterior column with posterior wall. The most unique fracture is the associated both column fracture, which completely dissociates the acetabular articular surface from the sciatic buttress. Accurate categorization of acetabular fractures is challenging because of the complex three-dimensional (3D) anatomy of the pelvis, the rarity of certain acetabular fracture variants, and confusing nomenclature. Comparing a 3D image of the fractured acetabulum with a standard diagram containing the 10 Judet and Letournel categories of acetabular fracture and using a flowchart algorithm are effective ways of arriving at the correct fracture classification. Online supplemental material is available for this article. PMID:25763739

  19. Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study

    PubMed Central

    Huang, De-Yong; Zhang, Liang; Zhou, Yi-Xin; Zhang, Chun-Yu; Xu, Hui; Huang, Yong

    2016-01-01

    Background: Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures, and good results have been reported with the use of these cups; however, the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear. This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures. Methods: A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012. Among these patients, two were lost to follow-up. Therefore, 39 patients (39 hips) were finally included in this study. The Harris hip score before and after the surgery, satisfaction level of the patients, and radiographic results were assessed. Results: The mean Harris hip score increased from 34 (range, 8–52) before surgery to 91 (range, 22–100) at the latest follow-up examination (P < 0.001). The results were excellent for 28 hips, good for six, fair for three, and poor for two. Among the 39 patients, 25 (64%) and 10 (26%) were very satisfied and somewhat satisfied, respectively. All cups were found to be fully incorporated, and no evidence of cup migration or periacetabular osteolysis was noted. Conclusions: Despite the technically demanding nature of the procedure, THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures. PMID:27064033

  20. OPERATIVE TREATMENT OF TRANSVERSE ACETABULAR FRACTURES: IS IT REALLY NECESSARY TO FIX BOTH COLUMNS?

    PubMed Central

    Giordano, Vincenzo; do Amaral, Ney Pecegueiro; Pallottino, Alexandre; Albuquerque, Rodrigo Pires e; Franklin, Carlos Eduardo; Labronici, Pedro José

    2009-01-01

    Objective: we prospectively evaluated clinical and radiographic outcomes in patients with displaced combined transverse-posterior wall acetabular fractures managed at our Institution over a period of seven years by posterolateral single approach, direct posterior wall and posterior column reduction and plating, and indirect reduction of anterior column controlled by fluoroscopic images with or without lag-screw fixation. The aim was to identify if the obtained immediate postoperative Matta radiographic roof-arc angles after fracture reduction and fixation alters in the postoperative period when comparing posterior plating alone versus posterior plate and anterior column lag-screw fixation. Patients and Methods: 35 skeletally mature patients (31 male and four female, with mean age of 39.9 years old [range, 23.3 to 66.7 y/o]) with combined transverse-posterior wall acetabular fractures surgically treated by a posterolateral single approach were enrolled in this prospective investigation. Nineteen patients had associated orthopaedic injuries. The first part of the acetabular fracture management was similar to all patients and consisted in anatomical reduction and fixation of the transverse posterior component followed by anatomical reduction and fixation of the posterior wall component. The transverse anterior component reduction was controlled by fluoroscopic images (anteroposterior (AP), iliac oblique, and obturator oblique views) and digital palpation through the greater sciatic notch. Fifteen of the 35 patients had an additional lag-screw fixation from the posterior to the anterior columns with an extra-long small-fragment cortical screw. AP and Judet oblique radiographic views were taken at the end of the procedure and roof-arc angles were measured. Clinical results were assigned according to the grading system of Merle D'Aubigne´ and Postel as modified by Matta et al. Radiographic roof-arc angles were checked and compared between the two groups of patients to

  1. ANALYSIS OF THE SEGMENTAL IMPACTION OF FEMORAL HEAD FOLLOWING AN ACETABULAR FRACTURE SURGICALLY MANAGED

    PubMed Central

    Guimarães, Rodrigo Pereira; Kaleka, Camila Cohen; Cohen, Carina; Daniachi, Daniel; Keiske Ono, Nelson; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Riccioli, Walter

    2015-01-01

    Objective: Correlate the postoperative radiographic evaluation with variables accompanying acetabular fractures in order to determine the predictive factors for segmental impaction of femoral head. Methods: Retrospective analysis of medial files of patients submitted to open reduction surgery with internal acetabular fixation. Within approximately 35 years, 596 patients were treated for acetabular fractures; 267 were followed up for at least two years. The others were excluded either because their follow up was shorter than the minimum time, or as a result of the lack of sufficient data reported on files, or because they had been submitted to non-surgical treatment. The patients were followed up by one of three surgeons of the group using the Merle d'Aubigné and Postel clinical scales as well as radiological studies. Results: Only tow studied variables-age and amount of postoperative reductionshowed statistically significant correlation with femoral head impaction. Conclusions: The quality of reduction-anatomical or with up to 2mm residual deviation-presents a good radiographic evolution, reducing the potential for segmental impaction of the femoral head, a statistically significant finding. PMID:27004191

  2. Fixation of acetabular fractures via the ilioinguinal versus pararectus approach: a direct comparison.

    PubMed

    Märdian, S; Schaser, K D; Hinz, P; Wittenberg, S; Haas, N P; Schwabe, P

    2015-09-01

    This study compared the quality of reduction and complication rate when using a standard ilioinguinal approach and the new pararectus approach when treating acetabular fractures surgically. All acetabular fractures that underwent fixation using either approach between February 2005 and September 2014 were retrospectively reviewed and the demographics of the patients, the surgical details and complications were recorded. A total of 100 patients (69 men, 31 women; mean age 57 years, 18 to 93) who were consecutively treated were included for analysis. The quality of reduction was assessed using standardised measurement of the gaps and steps in the articular surface on pre- and post-operative CT-scans. There were no significant differences in the demographics of the patients, the surgical details or the complications between the two approaches. A significantly better reduction of the gap, however, was achieved with the pararectus approach (axial: p = 0.025, coronal: p = 0.013, sagittal: p = 0.001). These data suggest that the pararectus approach is at least equal to, or in the case of reduction of the articular gap, superior to the ilioinguinal approach. This approach allows direct buttressing of the dome of the acetabulum and the quadrilateral plate, which is particularly favourable in geriatric fracture patterns. PMID:26330596

  3. Subchondral Insufficiency Fracture of the Femoral Head Caused by Excessive Lateralization of the Acetabular Rim

    PubMed Central

    Kimura, Tetsuya; Goto, Tomohiro; Hamada, Daisuke; Tsutsui, Takahiko; Wada, Keizo; Fukuta, Shoji; Nagamachi, Akihiro; Sairyo, Koichi

    2016-01-01

    We present a case of a 53-year-old woman with subchondral insufficiency fracture (SIF) of the femoral head without history of severe osteoporosis or overexertion. Plain radiographs showed acetabular overcoverage with excessive lateralization of the acetabular rim. A diagnosis of SIF was made by typical MRI findings of SIF. The lesion occurred at the antipodes of the extended rim. Increased mechanical stress over the femoral head due to impingement against the excess bone was suspected as a cause of SIF. The distinct femoral head deformity is consistent with this hypothesis. This is the first report of SIF associated with acetabular overcoverage. PMID:27293935

  4. Biomechanical Analysis of the Fixation System for T-Shaped Acetabular Fracture

    PubMed Central

    Fan, Yanping; Lei, Jianyin; Zhu, Feng; Li, Zhiqiang; Chen, Weiyi; Liu, Ximing

    2015-01-01

    This study aims to evaluate the biomechanical mechanism of fixation systems in the most frequent T-shaped acetabular fracture using finite element method. The treatment of acetabular fractures was based on extensive clinical experience. Three commonly accepted rigid fixation methods (double column reconstruction plates (P × 2), anterior column plate combined with posterior column screws (P + PS), and anterior column plate combined with quadrilateral area screws (P + QS)) were chosen for evaluation. On the basis of the finite element model, the biomechanics of these fixation systems were assessed through effective stiffness levels, stress distributions, force transfers, and displacements along the fracture lines. All three fixation systems can be used to obtain effective functional outcomes. The third fixation system (P + QS) was the optimal method for T-shaped acetabular fracture. This fixation system may reduce many of the risks and limitations associated with other fixation systems. PMID:26495030

  5. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture.

    PubMed

    Jo, Woo Lam; Lee, Woo Suk; Chae, Dong Sik; Yang, Ick Hwan; Lee, Kyoung Min; Koo, Kyung Hoi

    2016-10-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum. PMID:27550496

  6. Biomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?

    PubMed Central

    Wu, Yong-De; Cai, Xian-Hua; Liu, Xi-Ming; Zhang, Hong-Xi

    2013-01-01

    OBJECTIVE: The acetabular buttress-plate has been widely used in treating difficult cases with satisfying clinical results. However, the biomechanical properties of a postoperative acetabular fracture fixed by the buttress-plate are not clear. The purpose of this study was to evaluate the biomechanical properties of stability after the anterior tube buttress-plate fixation of complex acetabular fractures in the quadrilateral area. METHODS: A construct was proposed based on anterior construct plate - 1/3 tube buttress plate fixation for acetabular both-column fractures. Two groups of six formalin-preserved cadaveric pelvises were analyzed: (1) group A, the normal pelvis and (2) group B, anterior construct plate-1/3 tube buttress plate with quadrilateral area fixation. The displacements were measured, and cyclical loads were applied in both standing and sitting simulations. RESULTS: As the load was added, the displacements were A

  7. Methods and Guidelines for Venous Thromboembolism Prevention in Polytrauma Patients with Pelvic and Acetabular Fractures

    PubMed Central

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Haro, José Antonio Calvo; Vaquero-Martín, Javier

    2015-01-01

    Sequential compression devices and chemical prophylaxis are the standard venous thromboembolism (VTE) prevention for trauma patients with acetabular and pelvic fractures. Current chemical pharmacological contemplates the use of heparins or fondaparinux. Other anticoagulants include coumarins and aspirin, however these oral agents can be challenging to administer and may need monitoring. When contraindications to anticoagulation in high-risk patients are present, prophylactic inferior vena cava filters can be an option to prevent pulmonary emboli. Unfortunately strong evidence about the most effective method, and the timing of their commencement, in patients with pelvic and acetabular fractures remains controversial. PMID:26312115

  8. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    PubMed Central

    Sinha, Skand; Naik, Ananta k; Arya, Rajendra K; Jain, Vijay K

    2013-01-01

    Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS) plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. PMID:27298928

  9. Custom-made locked plating for acetabular fracture: a pilot study in 24 consecutive cases.

    PubMed

    Xu, Meng; Zhang, Li-Hai; Zhang, Ying-Ze; Zhang, Li-Cheng; He, Chun-Qing; Wang, Yan; Tang, Pei-Fu

    2014-07-01

    Clinical implementation of site-specific locking plates for acetabular fracture remains untested. Custom-made locking plates were manufactured using computer-aided design and computer-aided manufacture techniques for acetabular fractures to test this procedure. The 3-dimensional images constructed from computed tomography data of pelvises in patients with acetabular fractures were used for preoperative planning and to design the plates. Data for each plate were input into software for programming, and the generated code was transferred into a computerized numerical control digital milling machine for manufacturing. These plates were clinically implemented, and the implementation parameters, reduction quality, and Postel Merle d'Aubigné score were evaluated. Forty-nine custom-made locking plates were manufactured for 24 unilateral acetabular fractures. The manufacturing process for the plates averaged 6.9±2.2 days. Processing the plates delayed operations by 2.6±1.3 days in one-third of the cases. Plate contouring was avoided in 48 plates. The plates had anatomical shapes, excellently matching reduced bone surface. The screws locked with the obtained plates avoided intra-articular penetration and provided secure fixation that allowed early out-of-bed rehabilitation. No indications of implant failures or observations of screw back-outs were observed during follow-up. The clinical application of such plates is associated with the avoidance of plate contouring, low risk of intra-articular penetration, early out-of-bed rehabilitation, and a low rate of implant failure. Implementing such plates in clinical practice is worthy of further investigation, with a focus on selecting patient population and minimizing the time required for and cost of plate manufacturing. PMID:24992064

  10. Temporary Balloon Occlusion of the Abdominal Aorta in Treatment of Complex Acetabular Fracture

    PubMed Central

    Hao, Zhenhai; Zhou, Dongsheng; Wang, Fu; Li, Lianxin; He, Jiliang

    2016-01-01

    Background The aim of this study was to explore the efficacy of temporary balloon occlusion of the abdominal aorta assisting open reduction and internal fixation (ORIF) in the treatment of complex acetabular fracture. Material/Methods From August 2000 to October 2011, a total of 48 patients with complex acetabular fracture were enrolled in this study. Average operative time, intraoperative blood loss volume, blood transfusion volume, satisfactory reduction, and postoperative functional recovery rate were recorded and compared between the 2 groups. Results A significant difference was observed between the 2 groups in operative time (P=0.003). For intraoperative blood loss and blood transfusion, ORIF combined with temporary balloon occlusion of abdominal aorta techniques appeared to be superior to normal ORIF (blood loss: P=0.007; and blood transfusion: P=0.019, respectively). However, no differences were observed in postoperative blood loss or transfusion (P>0.05). Patients in group A showed better hip function than those in group B (group A: a good-to-excellent rate of 77.8%; group B: a good-to-excellent rate of 78.3%; P>0.05). With regard to the incidence of postoperative complications, there were no significant differences between the 2 groups (group A: 9/18; group B: 11/23; P=0.890). Conclusions In the treatment of complex acetabular fracture, temporary balloon occlusion of the abdominal aorta is a reliable technique to assist ORIF surgery to staunch the flow of blood. PMID:27367975

  11. [Aseptic, simultaneous and bilateral mobilisation due to an acetabular shell fracture in a 43 year-old patient].

    PubMed

    Ceretti, M; Fanelli, M; Pappalardo, S

    2014-01-01

    The acetabular shell mobilization is the main long-term complication in total hip replacement. Metal-back fracture has also to be considered among the possible causes of shell mobilization. A case is presented of bilateral acetabular shell mobilization due to the trabecular covering de-soldering from the metal-back in a 43 year-old patient, 13-14 years after the first surgery. PMID:24360788

  12. Survival of ceramic bearings in total hip replacement after high-energy trauma and periprosthetic acetabular fracture.

    PubMed

    Salih, S; Currall, V A; Ward, A J; Chesser, T J S

    2009-11-01

    Surgeons remain concerned that ceramic hip prostheses may fail catastrophically if either the head or the liner is fractured. We report two patients, each with a ceramic-on-ceramic total hip replacement who sustained high-energy trauma sufficient to cause a displaced periprosthetic acetabular fracture in whom the ceramic bearings survived intact. Simultaneous fixation of the acetabular fracture, revision of the cementless acetabular prosthesis and exchange of the ceramic bearings were performed successfully in both patients. Improved methods of manufacture of new types of alumina ceramic with a smaller grain size, and lower porosity, have produced much stronger bearings. Whether patients should be advised to restrict high-impact activities in order to protect these modern ceramic bearings from fracture remains controversial. PMID:19880903

  13. Supra-acetabular fixation and sacroiliac screws for treating unstable pelvic ring injuries: preliminary results from 20 patients☆

    PubMed Central

    Guimarães, Rodrigo Pereira; de Góes Ribeiro, Arthur; Ulson, Oliver; de Ávila, Ricardo Bertozzi; Ono, Nelson Keiske; Polesello, Giancarlo Cavalli

    2016-01-01

    Objective To analyze the treatment results from 20 patients who underwent an alternative osteosynthesis method as definitive treatment for pelvic ring fractures. Methods A retrospective analysis was conducted on a series of 20 patients with pelvic ring fractures (Tile type C) and a high risk of postoperative infection, who were treated at Santa Casa de Misericórdia de São Paulo between August 2004 and December 2012. The patients underwent percutaneous supra-acetabular external fixation in association with cannulated 7.0 mm iliosacral screws. Results The patients’ mean age was 40 years (range 22–77 years) and the mean length of follow-up was 18.5 months (range 3–69 months). At the end of the treatment, ten patients (50%) were classified as having good results, nine patients (45%) had fair results and one patient (5%) did not have any improvement. Six patients presented complications, and paresthesia of the lateral femoral cutaneous nerve was the most frequent of these (two patients). Conclusion Supra-acetabular external fixation in association with iliosacral percutaneous osteosynthesis is a good definitive treatment method for patients with a high risk of postoperative infection. PMID:27069879

  14. Percutaneous screw fixation of acetabular fractures: applicability of hip arthroscopy.

    PubMed

    Yang, Jae-Hyuk; Chouhan, Devendra Kumar; Oh, Kwang-Jun

    2010-11-01

    Percutaneous screw fixation of the anterior column of the acetabulum has been a challenging task because of its unique anatomy and a risk of intra-articular penetration. Evidence is lacking for any tools to provide visual scrutiny of fracture reduction and intra-articular screw penetration. We report 2 cases of fracture of the acetabulum that developed in young female athletes, in which the anterior column was fixed with a percutaneous screw by use of hip arthroscopy as an assisting tool for intra-articular observation. In our experience this method was found to be promising in terms of anatomic reduction of the fracture site, avoiding articular penetration during screw insertion, with additional advantages of joint debridement, lavage, and reduction in radiation exposure. PMID:20888169

  15. A Feasibility Study into the Use of Three-Dimensional Printer Modelling in Acetabular Fracture Surgery

    PubMed Central

    Yu, A. W.; Duncan, J. M.; Daurka, J. S.; Lewis, A.; Cobb, J.

    2015-01-01

    There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient's unique anatomy can only lead to improved outcomes. PMID:25709843

  16. Femoroacetabular impingement with chronic acetabular rim fracture - 3D computed tomography, 3D magnetic resonance imaging and arthroscopic correlation

    PubMed Central

    Chhabra, Avneesh; Nordeck, Shaun; Wadhwa, Vibhor; Madhavapeddi, Sai; Robertson, William J

    2015-01-01

    Femoroacetabular impingement is uncommonly associated with a large rim fragment of bone along the superolateral acetabulum. We report an unusual case of femoroacetabular impingement (FAI) with chronic acetabular rim fracture. Radiographic, 3D computed tomography, 3D magnetic resonance imaging and arthroscopy correlation is presented with discussion of relative advantages and disadvantages of various modalities in the context of FAI. PMID:26191497

  17. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation

    PubMed Central

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Kim, Dong-Yeol; Zheng, Long

    2015-01-01

    Background Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. Methods From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. Results There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p < 0.001, respectively). However, there were no significant differences in hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Conclusions Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays

  18. An Effective and Feasible Method, “Hammering Technique,” for Percutaneous Fixation of Anterior Column Acetabular Fracture

    PubMed Central

    Zhang, Lihai; Zhang, Wei; Li, Tongtong; Li, Jiantao; Chen, Hua

    2016-01-01

    Objective. The objective of this study was to evaluate the effectiveness and advantages of percutaneous fixation of anterior column acetabular fracture with “hammering technique.” Materials and Methods. We retrospectively reviewed 16 patients with percutaneous fixation of anterior column acetabular fracture with “hammering technique.” There were 11 males and 5 females with an average age of 38.88 years (range: 24–54 years) in our study. Our study included 7 nondisplaced fractures, 6 mild displaced fractures (<2 mm), and 5 displaced fractures (>2 mm). The mean time from injury to surgery was 4.5 days (range: 2–7 days). Results. The average of operation time was 27.56 minutes (range: 15–45 minutes), and the mean blood loss was 55.28 mL (range: 15–100 mL). The mean fluoroscopic time was 54.78 seconds (range: 40–77 seconds). The first pass of the guide wire was acceptable without cortical perforation or intra-articular perforation in 88.89% (16/18) of the procedures, and the second attempt was in 11.11% (2/18). Conclusion. Our study suggested that percutaneous fixation of anterior column acetabular fracture with “hammering technique” acquired satisfying surgical and clinical outcomes. It may be an alternative satisfying treatment for percutaneous fixation of anterior column acetabular fracture by 2D fluoroscopy using a C-arm with less fluoroscopic time. PMID:27493962

  19. Prophylactic radiotherapy against heterotopic ossification following internal fixation of acetabular fractures: a comparative estimate of risk

    PubMed Central

    Nasr, P; Yip, G; Scaife, J E; House, T; Thomas, S J; Harris, F; Owen, P J; Hull, P

    2014-01-01

    Objective: Radiotherapy (RT) is effective in preventing heterotopic ossification (HO) around acetabular fractures requiring surgical reconstruction. We audited outcomes and estimated risks from RT prophylaxis, and alternatives of indometacin or no prophylaxis. Methods: 34 patients underwent reconstruction of acetabular fractures through a posterior approach, followed by a 8-Gy single fraction. The mean age was 44 years. The mean time from surgery to RT was 1.1 days. The major RT risk is radiation-induced fatal cancer. The International Commission on Radiological Protection (ICRP) method was used to estimate risk, and compared with a method (Trott and Kemprad) specifically for estimating RT risk for benign disease. These were compared with risks associated with indometacin and no prophylaxis. Results: 28 patients (82%) developed no HO; 6 developed Brooker Class I; and none developed Class II–IV HO. The ICRP method suggests a risk of fatal cancer in the range of 1 in 1000 to 1 in 10,000; the Trott and Kemprad method suggests 1 in 3000. For younger patients, this may rise to 1 in 2000; and for elderly patients, it may fall to 1 in 6000. The risk of death from gastric bleeding or perforation from indometacin is 1 in 180 to 1 in 900 in older patients. Without prophylaxis risk of death from reoperation to remove HO is 1 in 4000 to 1 in 30,000. Conclusion: These results are encouraging, consistent with much larger series and endorse our multidisciplinary management. Risk estimates can be used in discussion with patients. Advances in knowledge: The risk from RT prophylaxis is small, it is safer than indometacin and substantially overlaps with the range for no prophylaxis. PMID:25089852

  20. Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate following press-fit implantation.

    PubMed

    Ong, Kevin L; Rundell, Steve; Liepins, Imants; Laurent, Ryan; Markel, David; Kurtz, Steven M

    2009-11-01

    Press-fit implantation may result in acetabular component deformation between the ischial-ilial columns ("pinching"). The biomechanical and clinical consequences of liner pinching due to press-fit implantation have not been well studied. We compared the effects of pinching on the polyethylene fracture risk, potential wear rate, and stresses for two different thickness liners using computational methods. Line-to-line ("no pinch") reaming and 2 mm underreaming press fit ("pinch") conditions were examined for Trident cups with X3 polyethylene liner wall thicknesses of 5.9 mm (36E) and 3.8 mm (40E). Press-fit cup deformations were measured from a foam block configuration. A hybrid material model, calibrated to experimentally determined stress-strain behavior of sequentially annealed polyethylene, was applied to the computational model. Molecular chain stretch did not exceed the fracture threshold in any cases. Nominal shell pinch of 0.28 mm was estimated to increase the volumetric wear rate by 70% for both cups and peak contact stresses by 140 and 170% for the 5.9 and 3.8 mm-thick liners, respectively. Although pinching increases liner stresses, polyethylene fracture is highly unlikely, and the volumetric wear rates are likely to be low compared to conventional polyethylene. PMID:19489047

  1. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    PubMed

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. PMID:26528936

  2. A novel fixation system for acetabular quadrilateral plate fracture: a comparative biomechanical study.

    PubMed

    Zha, Guo-Chun; Sun, Jun-Ying; Dong, Sheng-Jie; Zhang, Wen; Luo, Zong-Ping

    2015-01-01

    This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fracture; the better biomechanical performance of the AFRIF compared with the T-shaped plate fixation (TPF), L-shaped plate fixation (LPF), and H-shaped plate fixation (HPF); AFRIF gives reasonable stability of treatment for quadrilateral plate fracture and may offer a better solution for comminuted quadrilateral plate fractures or free floating medial wall fracture and be reliable in preventing protrusion of femoral head. PMID:25802849

  3. Nanotechnology for treating osteoporotic vertebral fractures

    PubMed Central

    Gao, Chunxia; Wei, Donglei; Yang, Huilin; Chen, Tao; Yang, Lei

    2015-01-01

    Osteoporosis is a serious public health problem affecting hundreds of millions of aged people worldwide, with severe consequences including vertebral fractures that are associated with significant morbidity and mortality. To augment or treat osteoporotic vertebral fractures, a number of surgical approaches including minimally invasive vertebroplasty and kyphoplasty have been developed. However, these approaches face problems and difficulties with efficacy and long-term stability. Recent advances and progress in nanotechnology are opening up new opportunities to improve the surgical procedures for treating osteoporotic vertebral fractures. This article reviews the improvements enabled by new nanomaterials and focuses on new injectable biomaterials like bone cements and surgical instruments for treating vertebral fractures. This article also provides an introduction to osteoporotic vertebral fractures and current clinical treatments, along with the rationale and efficacy of utilizing nanomaterials to modify and improve biomaterials or instruments. In addition, perspectives on future trends with injectable bone cements and surgical instruments enhanced by nanotechnology are provided. PMID:26316746

  4. Nanotechnology for treating osteoporotic vertebral fractures.

    PubMed

    Gao, Chunxia; Wei, Donglei; Yang, Huilin; Chen, Tao; Yang, Lei

    2015-01-01

    Osteoporosis is a serious public health problem affecting hundreds of millions of aged people worldwide, with severe consequences including vertebral fractures that are associated with significant morbidity and mortality. To augment or treat osteoporotic vertebral fractures, a number of surgical approaches including minimally invasive vertebroplasty and kyphoplasty have been developed. However, these approaches face problems and difficulties with efficacy and long-term stability. Recent advances and progress in nanotechnology are opening up new opportunities to improve the surgical procedures for treating osteoporotic vertebral fractures. This article reviews the improvements enabled by new nanomaterials and focuses on new injectable biomaterials like bone cements and surgical instruments for treating vertebral fractures. This article also provides an introduction to osteoporotic vertebral fractures and current clinical treatments, along with the rationale and efficacy of utilizing nanomaterials to modify and improve biomaterials or instruments. In addition, perspectives on future trends with injectable bone cements and surgical instruments enhanced by nanotechnology are provided. PMID:26316746

  5. A minimally invasive surgical technique to treat distal clavicle fractures.

    PubMed

    Swanson, Kyle E; Swanson, Britta L

    2009-07-01

    Treatment of distal clavicle fractures ranges from nonoperative to operative approaches. Various surgical procedures have been described in the literature, each with potential complications. For fractures treated operatively, the goal is to maximize stability and functionality while minimizing pain and deformity. This article describes a double-button suture system using a mini-open technique to repair a distal clavicle fracture providing stable fixation with minimal disruption of the surrounding anatomy. PMID:19634845

  6. Treating Tibia Fractures With Far Cortical Locking Implants.

    PubMed

    Rice, Christopher; Christensen, Thomas; Bottlang, Michael; Fitzpatrick, Dan; Kubiak, Erik

    2016-01-01

    Compared with conventional plating, the relatively new technology of far cortical locking (FCL) allows for more flexible fixation. Increased flexibility of FCL constructs is thought to better stimulate secondary osteosynthesis and lead to improved healing for certain fracture patterns. We conducted a study to compare healing rates and complications of tibial fractures treated with FCL or standard plating techniques. Twenty-two patients with fractures of the tibia (Orthopaedic Trauma Association 41ABC, 42C, 43C) were included in the study. Twelve tibia fractures were treated with FCL and 10 with standard plating (locking or nonlocking). Mean follow-up was 47 weeks in the FCL group and 41 weeks in the control group. The fracture healing rate was 92% in the FCL group and 100% in the control group (difference not statistically significant). Of note, there were 2 open fractures in the FCL group and 0 in the control group. The groups had similar complication rates. Our study data suggest FCL implants are not inferior to conventional plating techniques. Given that FCL-treated fractures tended to be more complex, the groups' similar fracture healing rates may indicate improved fracture healing with FCL technology, but this possibility requires further investigation. PMID:26991582

  7. Preventing and Treating Compression Fractures of the Spine

    MedlinePlus

    Preventing and Treating Compression Fractures of the Spine 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981-2663 (301) 947-0083 Fax: (301) ... as contact sports obviously increase the risk of fracture. Other activities that may not seem to be ...

  8. [Unexpected revision procedures treating ankle fractures].

    PubMed

    Richter, J; Pommer, A; Breuer, R; Hullmann, S; Heyde, D V; Dávid, A

    2012-06-01

    The purpose of the present study was to analyze the risk factors associated with unexpected second procedures and strategies of revision surgery. Within a 5 year period 647 patients with closed ankle fractures AO type 44 were identified of which 77 (11.9%) needed revision surgery. Complications were addressed to 4 main groups: deep infections (IG) were seen in 29 patients (4.5%), problems with primary wound closure (WG) in 22 patients (3.4%), insufficient reduction (KG) in 22 patients (3.4%) and other causes (RG) included 4 patients (0.6%). Significant predictive factors for soft tissue complications were higher age, comorbidities with peripheral arteriosclerosis, high American Society of Anesthesiologists (ASA) score and diabetes mellitus. AO 44 type B2 and B3 fractures were often associated with soft tissue problems. The more complex fracture types AO 44 C1-C3 and A2-A3 were significantly associated with problems of insufficient congruency post-surgery. The distribution of the mean revision rate was significantly different (p<0.01) for all groups: IG 4.59, WG 3.5, KG 1.55, RG 1.25. In summary, we strongly recommend immediate reduction of displaced fractures and to consider a more detailed fracture classification. To reduce the amount of unexpected ankle procedures individual risk factors should be weighed against the advantages of optimal open reduction and internal fixation. PMID:21165587

  9. Bifocal mandibular fractures: which should be treated first?

    PubMed

    Dell' Aversana Orabona, Giovanni; Iaconetta, Giorgio; Abbate, Vincenzo; Califano, Luigi

    2012-11-01

    Fractures of the mandible have been reported to account between 40% and 62% of all facial fractures. Most surveys show that just under 50% are isolated, the same amount are doubly fractured. This study aims to clarify, according to our experience, the correct surgical sequence which should be followed in order to treat bifocal mandibular fractures. From January 2004 to January 2009, we have conducted a retrospective study on a sample of patients operated on in our department because of bifocal mandibular fractures. We include only those cases in which the jaw was fractured in 2 places, in particular patients who suffer a fracture in tooth-bearing areas (symphysis, parasymphysis, and anterior body) and also contralaterally in non-tooth-bearing areas (posterior body, angle, ramus, and condyle). The sample was divided into 2 groups based on the fracture sequence of reduction. At 1-year follow-up, the group of patients who received first the tooth-bearing fractured areas treatment, followed by treatment of non-tooth-bearing fractured area on bifocal mandibular fracture, showed less postoperative complications and reduced surgical time and costs. It is recommended from this study that reduction of the tooth-bearing fragment be prior to that of the tooth-free fragment for the bifocal mandible. PMID:23147333

  10. Outcomes of Geriatric Hip Fractures Treated with AFFIXUS Hip Fracture Nail

    PubMed Central

    Mabrouk, Ahmed; Madhusudan, Mysore; Waseem, Mohammed; Kershaw, Steven

    2014-01-01

    Geriatric hip fractures are one of the commonest fractures worldwide. The purpose of this study was to report the outcomes of a series of unstable geriatric hip fractures treated with AFFIXUS hip fracture nail. A retrospective study of 100 unstable geriatric hip fractures treated with AFFIXUS hip fracture nail is presented. The mean follow-up duration was 8 months (range 3–32). Of the patients 83% were female. The average age was 85 years. The fracture was treated by closed reduction and intramedullary fixation. The mean acute hospital stay was 17.6 days. Systemic complications occurred in 29 patients (29%) and local complications in 3 patients (3%) including lag screw cutout in one patient (1%), lag screw backout in one patient (1%), and deep infection in one patient (1%). Mechanical failures and periprosthetic fractures were not observed in our series. Fractures united in all patients. Preinjury activity level was recovered in 78% of the patients. The results of AFFIXUS hip fracture nail were satisfactory in most elderly patients. The unique design of the lag screw and its thread spacing had effectively reduced cut-out rate. PMID:25580303

  11. Osteopathic diagnosis of an acetabular injury.

    PubMed

    Morthland, Tim; Cote, Nicholas S; Humphrey, Jon; Fulk, Doug

    2010-05-01

    Physical findings demarking pathologic somatovisceral reflex activity and fascial strain patterns may lead the osteopathic physician to diagnoses that are masked within the initial presentation of a patient. The authors present a case report that demonstrates the use of osteopathic principles in the diagnosis of a chronic acetabular fracture and acetabular labral tear in a 19-year-old man. The injuries resulted from a posterior hip dislocation sustained during a basketball game more than 1 year before presentation. Osteopathic manipulative treatment and diagnostic techniques also relieved the patient's persistent thoracic pain, nausea, and vomiting. Subsequent orthopedic repair had the potential to avert or delay degenerative hip disease in the patient. PMID:20538751

  12. Hemispheric titanium porous coated acetabular component without screw fixation.

    PubMed

    Dorr, L D; Wan, Z; Cohen, J

    1998-06-01

    One hundred fifteen hips in 108 patients with primary total hip arthroplasty using the anatomic porous replacement hemispheric acetabular component implanted without adjunctive screw fixation had a mean postoperative followup time of 6 years (range, 5-7.4 years). Clinical evaluation was performed using the Harris hip score and patient self assessment using a modified Short Form-36 questionnaire. Radiographs were measured for radiolucent lines, polyethylene wear, osteolysis, migration, and fractures. No acetabular metal shell had been revised for loosening or was radiographically loose with or without migration (more than 3 mm) at final followup. Reoperation was done in nine (8%) hips because of polyethylene insert wear or disassembly. No fracture of the acetabular bone occurred at the time of surgery or was observed on radiograph. Fixation of the metal shell was stable, with progressive radiolucent lines observed at final followup in 2% of the hips. Osteolysis was recorded in one patient with two acetabular components. The fixation of noncemented hemispheric porous coated acetabular components is more related to the technique of acetabular bone preparation and press fit implantation than to whether additional screws or peg fixation are used. Fixation of this acetabular component without screws at an average of 6 years after surgery is reproducible and predictable in primary hip arthroplasty. The design of modular polyethylene inserts has been improved and should reduce the wear rate of reoperations of the polyethylene insert. PMID:9646758

  13. Two cases of surgically treated feline patellar fractures.

    PubMed

    Guillaumot, P; Scotti, S; Carozzo, C; Bouvy, B; Genevois, J-P

    2008-01-01

    A transverse patellar fracture in a six-month-old cat was successfully treated by figure-of-eight dorsal wiring of the patella. A longitudinal patellar fracture with luxation of a large medial fragment in a 2.5-year-old cat was treated by lateral marginal patellectomy with a positive outcome. While adding material to the few veterinary reports in that species, in this brief communication, the authors discuss the aetiology, diagnosis, and the treatment of the presented cases with regards to findings in previously published feline cases. PMID:18545720

  14. Lateral decubitus for treating pertrochanteric fractures using cephalomedullary nails☆

    PubMed Central

    de Oliveira, Elton João Nunes; Hungria, José Octávio Soares; Bellan, Davi Gabriel; Borracini, Jonas Aparecido

    2015-01-01

    Objective To perform a retrospective radiographic evaluation on the fracture reduction and implant position in the femoral head among patients with pertrochanteric fractures who had been treated using a cephalomedullary nail in lateral decubitus; and to assess factors that might interfere with the quality of the fracture reduction and with the implant position in using this technique. Methods Nineteen patients with a diagnosis of pertrochanteric fractures of the femur who had been treated using cephalomedullary nails in lateral decubitus were evaluated. For outpatient radiographic evaluations, we used the anteroposterior view of the pelvis and lateral view of the side affected. We measured the cervicodiaphyseal angle, tip-apex distance (TAD), spatial position of the cephalic element in relation to the head, and the bispinal diameter. To make an anthropometric assessment, we used the body mass index. Two groups of patients were created: one in which all the criteria were normal (TAD ≤25 mm, cervicodiaphyseal angle between 130° and 135° and cephalic implant position in the femoral head in the central–central quadrant); and another group presenting alterations in some of the criteria for best prognosis. Results Female patients predominated (57.9%) and the mean age was 60 years. Seven patients presented a central–central cephalic implant position. One patient present a cervicodiaphyseal angle >135° and the maximum TAD was 32 mm; consequently, 12 patients presented some altered criteria (63.2%). None of the characteristics evaluated differed between the patients with all their criteria normal and those with some altered criteria, or showed any statistically significant association among them (p > 0.05). Conclusion The technique described here enabled good reduction and good positioning of the implant, independent of the anthropometric indices and type of fracture. PMID:26401500

  15. Acute Lumbar Burst Fracture Treated by Minimally Invasive Lateral Corpectomy

    PubMed Central

    Amaral, Rodrigo; Marchi, Luis; Oliveira, Leonardo; Coutinho, Thiago

    2013-01-01

    Burst fractures in acute spinal traumas are a difficult problem to solve. Different approaches and techniques have been utilized, but with high incidence of morbidity and mortality, besides unsatisfactory clinical and radiological results. Mini-open approaches recently emerged and have been shown to be safe and effective in the treatment of several spinal conditions. Here we report a case of acute lumbar burst fracture at L2 treated by minimally invasive true lateral approach posteriorly instrumented with percutaneous pedicle screws. The minimum disruptive access in addition to a rigid construction allowed a lumbar corpectomy without the morbidity of standard open approaches, lowering surgery costs and accelerating the patient recovery with successfully clinical and radiological results. PMID:23634314

  16. Intermediate clinical follow-up of a dual-radius acetabular component.

    PubMed

    Van Flandern, G J; Bierbaum, B E; Newberg, A H; Gomes, S L; Mattingly, D A; Karpos, P A

    1998-10-01

    In this study, 92 primary total hip arthroplasties were performed in 83 patients using a porous-coated, dual-radius, cementless, acetabular component. All hips underwent line-to-line dome reaming with press-fit implantation that was judged to have complete bone contact. This acetabular shell provides a 1-mm oversized peripheral rim, which adds excellent initial stability while allowing complete bone contact in all hips. No fractures occurred. In 83% of hips, adjunctive screw fixation was not necessary. At a minimum of 4 years, follow-up, there were no revisions, no acetabular migration, one case of acetabular erosion consistent with osteolysis, and the average Harris Hip Score was 95. The design features of this new acetabular component have provided excellent fixation with complete initial bone contact, resulting in satisfactory intermediate clinical and radiographic results. The design provides excellent peripheral stability and complete bone contact. PMID:9802669

  17. Combined Type II Odontoid Fracture with Jefferson's Fracture Treated with Temporary Internal Fixation.

    PubMed

    Pawar, Abhijit Yuvaraj; O'Leary, Patrick F

    2015-12-01

    An 18-year-old male presented after a motor vehicle rollover accident. Computed tomography (CT) scan confirmed the diagnosis of Type II odontoid fracture. Considering the patient's young age and the limitations of C1-C2 fusion including significant loss of cervical rotation, temporary internal fixation with a lateral mass fixation of C1 and pedicle fixation of C2 without fusion was done. CT scan done at 6-month follow-up visit showed healed odontoid fracture and excellent C1-C2 alignment. At ninth postoperative month, internal fixation was removed. Patient had normal movements of cervical spine at 1-year follow-up. Temporary internal fixation can be an important tool in the armamentarium of the surgeon in treating type II odontoid fractures in young adults and children. This strategy avoids the complications halo fixation and immobilizes the unstable C1-C2 segment without fusion. Removal of the internal fixation after healing allows restoration of the rotational motion. PMID:26713132

  18. The Use of a 3D Printer in Pre-operative Planning for a Patient Requiring Acetabular Reconstructive Surgery

    PubMed Central

    Duncan, James M; Nahas, Samuel; Akhtar, Kashif; Daurka, Jasvinder

    2015-01-01

    Introduction: Surgical management of acetabular fractures is often highly complex, and a successful outcome depends upon an appreciation of the fracture pattern and the most appropriate approach to reduce and hold it. Currently, computed tomography (CT) images are used in conjunction with plain x-rays to identify the main fracture components and their spatial relationship to one another, and as such surgeons still have to make decisions based upon their ability to visualise the fracture from the images available. 3D printers have now become widely available and inexpensive, and can be used to rapidly produce life-size models based on CT scans of an individual patient. The availability of patient specific, accurate and detailed models of complex acetabular fractures can aid planning of surgical management on a patient specific basis. Case Report: This report describes the use of a 3D printer to create a life-size model reconstruction of the pelvis of a 48 year old male patient who sustained a left sided associated both column acetabular fracture following a motorbike accident in the Sahara Desert. The model allowed visualisation of the multiple fracture fragments and their relative displacements. The tactile feedback allowed assessment of the different fracture fragments. The relative displacement of the quadrilateral plate and posterior column fragments could be assessed and the surgeon felt that these would be amenable to reduction from an ilioinguinal approach. An anatomic reduction was achieved and was held with the application of a pelvic brim plate with 2 screws lagging the posterior column/quadrilateral plate fragment. Conclusion: There are previous examples of 3D models being used in orthopaedic surgery through the use of rapid prototyping, however this method is usually expensive and time consuming. Advances in 3D printer technology offer surgeons a number of advantages when treating these complex fractures. With the ever-increasing economy, ease of use and

  19. Surgical management of fractures of the acetabulum: the Sheffield experience 1976-1994.

    PubMed

    Hull, J B; Raza, S A; Stockley, I; Elson, R A

    1997-01-01

    Of 56 acetabular fractures treated in Sheffield between 1976 and 1994, 43 fractures in 40 patients underwent open reduction and internal fixation. This paper reviews the surgically managed fractures with emphasis on the quality of operative reduction and outcome, in particular the development of degenerative osteoarthritis leading to total hip replacement. A good clinical result following operative management was seen to correlate closely with a near perfect reduction; in contrast, all cases with a poor reduction underwent joint replacement in the follow-up period. The relatively few cases managed at a major referral centre in this series suggest that either the incidence of acetabular fracture is low in the area or that only a proportion of cases are referred from the surrounding district general hospitals. PMID:9196624

  20. Increased Fracture Collapse after Intertrochanteric Fractures Treated by the Dynamic Hip Screw Adversely Affects Walking Ability but Not Survival

    PubMed Central

    Fang, Christian; Gudushauri, Paata; Wong, Tak-Man; Lau, Tak-Wing; Pun, Terence; Leung, Frankie

    2016-01-01

    In osteoporotic hip fractures, fracture collapse is deliberately allowed by commonly used implants to improve dynamic contact and healing. The muscle lever arm is, however, compromised by shortening. We evaluated a cohort of 361 patients with AO/OTA 31.A1 or 31.A2 intertrochanteric fracture treated by the dynamic hip screw (DHS) who had a minimal follow-up of 3 months and an average follow-up of 14.6 months and long term survival data. The amount of fracture collapse and shortening due to sliding of the DHS was determined at the latest follow-up and graded as minimal (<1 cm), moderate (1-2 cm), or severe (>2 cm). With increased severity of collapse, more patients were unable to maintain their premorbid walking function (minimal collapse = 34.2%, moderate = 33.3%, severe = 62.8%, and p = 0.028). Based on ordinal regression of risk factors, increased fracture collapse was significantly and independently related to increasing age (p = 0.037), female sex (p = 0.024), A2 fracture class (p = 0.010), increased operative duration (p = 0.011), poor reduction quality (p = 0.000), and suboptimal tip-apex distance of >25 mm (p = 0.050). Patients who had better outcome in terms of walking function were independently predicted by younger age (p = 0.036), higher MMSE marks (p = 0.000), higher MBI marks (p = 0.010), better premorbid walking status (p = 0.000), less fracture collapse (p = 0.011), and optimal lag screw position in centre-centre or centre-inferior position (p = 0.020). According to Kaplan-Meier analysis, fracture collapse had no association with mortality from 2.4 to 7.6 years after surgery. In conclusion, increased fracture collapse after fixation of geriatric intertrochanteric fractures adversely affected walking but not survival. PMID:26955637

  1. Increased Fracture Collapse after Intertrochanteric Fractures Treated by the Dynamic Hip Screw Adversely Affects Walking Ability but Not Survival.

    PubMed

    Fang, Christian; Gudushauri, Paata; Wong, Tak-Man; Lau, Tak-Wing; Pun, Terence; Leung, Frankie

    2016-01-01

    In osteoporotic hip fractures, fracture collapse is deliberately allowed by commonly used implants to improve dynamic contact and healing. The muscle lever arm is, however, compromised by shortening. We evaluated a cohort of 361 patients with AO/OTA 31.A1 or 31.A2 intertrochanteric fracture treated by the dynamic hip screw (DHS) who had a minimal follow-up of 3 months and an average follow-up of 14.6 months and long term survival data. The amount of fracture collapse and shortening due to sliding of the DHS was determined at the latest follow-up and graded as minimal (<1 cm), moderate (1-2 cm), or severe (>2 cm). With increased severity of collapse, more patients were unable to maintain their premorbid walking function (minimal collapse = 34.2%, moderate = 33.3%, severe = 62.8%, and p = 0.028). Based on ordinal regression of risk factors, increased fracture collapse was significantly and independently related to increasing age (p = 0.037), female sex (p = 0.024), A2 fracture class (p = 0.010), increased operative duration (p = 0.011), poor reduction quality (p = 0.000), and suboptimal tip-apex distance of >25 mm (p = 0.050). Patients who had better outcome in terms of walking function were independently predicted by younger age (p = 0.036), higher MMSE marks (p = 0.000), higher MBI marks (p = 0.010), better premorbid walking status (p = 0.000), less fracture collapse (p = 0.011), and optimal lag screw position in centre-centre or centre-inferior position (p = 0.020). According to Kaplan-Meier analysis, fracture collapse had no association with mortality from 2.4 to 7.6 years after surgery. In conclusion, increased fracture collapse after fixation of geriatric intertrochanteric fractures adversely affected walking but not survival. PMID:26955637

  2. Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion.

    PubMed

    Xu, Yongqiang; Lin, Chuangxin; Zhang, Lifeng; Lin, Miaoxiong; Lai, Jianqiang; Cao, Shenglu; Peng, Geng; Feng, Kai; Yan, Ge; Cai, Daozhang; Wang, Gang

    2016-01-01

    BACKGROUND The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. MATERIAL AND METHODS Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and computed tomography (CT) imaging were used to collect the measured parameter data of the module. RESULTS The measured parameter data were as follows: OP, 0.96±0.32 cm in females and 0.92±0.16 cm in males (P>0.05); PI, 0.98±0.28 cm in females, and 0.75±0.23 cm in males (P>0.05); Ðϴ, 59.68°±6.28° in females and 56.75°±3.22° in males (P>0.05); and Ðφ, 41.27°±2.76° in females and 34.31°±2.78° in males (P<0.05). The corresponding CT image data were as follows: PI, 1.08±0.22 cm in females and 0.85±0.27 cm in males (P>0.05); OP, 1.06±0.29 cm in females and 1.12±0.24 cm in males (P>0.05); Ðϴ, 55.33°±4.00° in females and 55. 50°±3.43° in males (P>0.05); and Ðφ was 39.21°±2.45°in females and 35.58°±2.31°in males (P<0.05). No significant difference with respect to sex and side existed between specimens and healthy adults (P>0.05). CONCLUSIONS The measured parameter data obtained in healthy adults and cadaveric specimens provided an anatomic basis for the designation of the guide module, and thus confirmed the accuracy and safety of screw placement in fractured columns of the acetabulum. PMID:27584820

  3. Outcome of humeral shaft fractures treated by functional cast brace

    PubMed Central

    Pal, Jitendra Nath; Biswas, Prahas; Roy, Avik; Hazra, Sunit; Mahato, Somnath

    2015-01-01

    Background: Functional brace application for isolated humeral shaft fracture persistently yields good results. Nonunion though uncommon involves usually the proximal third shaft fractures. Instead of polyethylene bivalve functional brace four plaster sleeves wrapped and molded with little more proximal extension expected to prevent nonunion of proximal third fractures. Periodic compressibility of the cast is likely to yield a better result. This can be applied on the 1st day of the presentation as an outpatient basis. Comprehensive objective scoring system befitting for fracture humeral shaft is a need. Materials and Methods: Sixty six (male = 40, female = 26) unilateral humeral shaft fractures of mean age 34.4 years (range 11–75 years) involving 38 left and 28 right hands were included in this study during April 2008 to December 2012. Fractures involved proximal (n = 18), mid (n = 35) and distal (n = 13) of humerus. Transverse, oblique, comminuted and spiral orientations in 18, 35 and 13 patients respectively. One had segmental fracture and three had a pathological fracture with cystic bone lesion. Mechanisms of injuries as identified in this study were road traffic accidents 57.6% (n = 38), fall 37.9% (n = 25). 12.1% (n = 8) had radial nerve palsy 7.6% (n = 5) had Type I open fracture. Four plaster strips of 12 layers and 5–7.5 cm broad depending on the girth of arm were prepared. Arm was then wrapped with single layer compressed cotton. Lateral and medial strips were applied and then after molding anterior and posterior strips were applied in such a way that permits full elbow range of motion and partial abduction of the shoulder. Care was taken to prevent adherence of one strip with other except in the proximal end. Limb was then put in loose collar and cuff sling intermittently allowing active motion of the elbow ROM and pendular movement of the shoulder. Weekly tightening of the cast by fresh layers of bandage over the existing cast brace continued

  4. A new device to treat intra-capsular fracture neck of femur non-union.

    PubMed

    Mukherjee, P; Ashworth, M J

    2010-12-01

    In adolescents and young adults, femoral neck fractures often result from high-velocity trauma. These fractures are usually of vertical shear pattern. There is an increased incidence of avascular necrosis and non-union, which is difficult to treat. Non-union of fractured neck of femur in young adults is a serious problem. There is growing evidence that these fractures should be treated with an angle-stable device to improve biomechanics at the fracture site. An ideal implant should prevent varus deformation and retroversion of the fracture in order to prevent failure of the osteosynthesis and thus preventing cut-out of implant and non-union at the fracture site. We report the first use of an Orthofix Gottfried Percutaneous Compression Plate (PC.C.P.) (Orthofix, Guilford, UK) to treat a non-union of an intra-capsular fractured neck of femur. We recommend this, in combination with autologous bone grafting, via a mini hip modification of the Smith-Petersen approach. PMID:21286362

  5. Assessment of Masticatory Function Using Bite Force Measurements in Patients Treated for Mandibular Fractures

    PubMed Central

    Sybil, Deborah; Gopalkrishnan, K.

    2013-01-01

    Bite force measurements are excellent criteria for assessment of masticatory efficiency. The purpose of this study was to assess the effect of mandibular fractures on the bite forces of patients treated for such fractures. Patients who were surgically treated for isolated mandibular fractures in the Department of Oral and Maxillofacial Surgery from January 2006 to December 2007 were included in the study. Patients were asked to bite on a bite force transducer on the first, fourth, sixth, and ninth postoperative weeks. The bite force values were compared with those of age, sex, and weight-matched controls. A total of 60 patients were included in the study. It was found that maximum bite forces in patients were significantly less than in controls for several weeks after surgery. After the ninth postoperative week, the maximum bite force measured < 65% the normal in patients with isolated angle fractures and > 80% the normal in patients with isolated parasymphysis fractures. The same values reduced to < 60% in patients with fractures of angle and parasymphysis and < 70% in patients with fractures of parasymphysis and condylar complex. An inverse relationship was found between the bite force values and the number of fractures of the mandible. We also found lower bite forces and longer period for normalization in patients who had fractures in those regions of the mandible which are more significantly associated with the masticatory apparatus for example angle or condyle of the mandible. PMID:24436769

  6. Protrusio After Medial Acetabular Wall Breach in Total Hip Arthroplasty

    PubMed Central

    Martin, Christopher T.; Heiner, Anneliese D.; Baer, Thomas E.; Pugely, Andrew J.; Noiseux, Nicolas O.

    2015-01-01

    Background Medial protrusio is a recognized complication of total hip arthroplasty, but it is not known if a medial wall breach during cup implantation increases the risk. We thus investigated the effect of up to a 2 cm defect in the medial acetabular wall in a cadaveric model. Separately, we investigated the ability of acetabular screws to rescue the construct. Methods Nine human fresh-frozen hemipelves were reamed medially to create the defect, implanted with acetabular cups, and then loaded to failure. The nine contralateral hemipelves were reamed in a standard fashion and served as controls. Separately, nine hemipelves with a medial defect were augmented with two acetabular screws each, then loaded to failure, with the contralateral side as a control. Load-to-failure, stiffness, and energy were recorded. Findings The presence of a medial wall defect decreased the load-to-failure by a mean of 26% (5710 v. 4221 N, p=0.024). The addition of two acetabular screws did not rescue the construct (mean 27% decrease, 4082 v. 2985 N, p=0.024). The majority of specimens failed in a supra-physiologic range of force. Bone density correlated with failure loads (R2 range of 0.54-0.78), and osteoporotic specimens were more likely to fail at a physiologic range, consistent with forces experienced during minor stumbles or falls. Interpretation Osteoporotic patients with a medial wall defect after hip arthroplasty may be susceptible to fracture during activities of daily living. Protected weight bearing with an assistive device may be reasonable in order to minimize fall risk until cup ingrowth is achieved. PMID:26361450

  7. Porous Tantalum Buttress Augments for Severe Acetabular Posterior Column Deficiency.

    PubMed

    Meneghini, R Michael; Hull, Jason R; Russo, Glenn S; Lieberman, Jay R; Jiranek, William A

    2015-11-01

    In revision total hip arthroplasty (THA), consensus is lacking regarding the optimal method for reconstruction of the most severe acetabular defects. Porous tantalum (TM) buttress augments were designed for the most severe postero-superior defects. The purpose of this study was to report the results of a consecutive series of acetabular reconstructions utilizing TM buttress augments. Eight complex acetabular reconstructions utilizing a TM buttress augment were performed at two centers. All were Paprosky 3A or Paprosky 3B bone loss classification, with severe superior and posterior column deficiency where wedge augments were insufficient for mechanical support. The acetabular cup sizes ranged from 64-78, and a buttress shim was used in 7 of 8 cases. Clinical and radiographic follow-up averaged 16.5 months (range, 10-28) and no cases were lost to follow-up. There were no cases of clinical or radiographic loosening, and no case had required reoperation or revision. All patients except one were ambulating with either no assist device or a single cane at final follow-up. There was one complication of an iliac wing fracture noted incidentally on postoperative x-rays in the lone patient in whom a buttress shim was not used. At short-term follow-up, TM acetabular buttress augments appear to effectively substitute for the use of structural allografts or cages, which would otherwise be used in this challenging setting. The potential for biologic fixation is promising for the durability of these reconstructions; however, longer-term follow-up is required for full evaluation. PMID:26680404

  8. Numerical Fracture Analysis of Cryogenically Treated Alloy Steel Weldments

    NASA Astrophysics Data System (ADS)

    Rasool Mohideen, S.; Thamizhmanii, S.; Fatah, M. M. Muhammed Abdul; Saidin, W. Najmuddin W.

    2016-02-01

    Cryogenic treatment is being used commercially in the industries in the last two decades for improving the life of many engineering component such as bearings and cutting tools. Though their influence in improving the wear resistance of tool materials is well established, the effect of treatment on weldments is not much investigated. In the present work, a two dimensional finite element analysis was carried out on the compact tension specimen model for simulating the treatment process and to study the fracture behaviour. The weldments were modelled by thermo- mechanical coupled field analysis for simulating he temperature distribution in the model during weld pool cooling and introducing thermal stresses due to uneven contraction and cooling. The model was subjected to cryogenic treatment by adopting radiation effect. The fracture analysis was carried out using Rice's J- Integral approach. The analysis produced a similar outcome of experimental results i.e. Increase in the fracture toughness of the specimen after cryogenic treatment in the heat affected zone of weldment.

  9. Mandibular angle fracture treated with new three-dimensional grid miniplate.

    PubMed

    de Melo, Willian Morais; Antunes, Antonio Azoubel; Sonoda, Celso Koogi; Hochuli-Vieira, Eduardo; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real

    2012-09-01

    Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability. PMID:22976690

  10. Options for acetabular fixation surfaces.

    PubMed

    Klika, Alison K; Murray, Trevor G; Darwiche, Hussein; Barsoum, Wael K

    2007-01-01

    Aseptic loosening is the most common cause for revision total hip arthroplasty (THA). Due to poor long-term results with cemented acetabular components, cementless implants that rely on biologic fixation became popular in the United States for both primary and revision procedures in the early 1980s. Cementless acetabular components used in THA have been reported to have superior radiographic performance compared with cemented fixation, although the optimal method of acetabular fixation remains controversial. Cementless acetabular components require initial implant stability to allow for bone ingrowth and remodeling into the acetabular shell, providing long-term durability of the prosthesis. Many improved implant materials are available to facilitate bone growth and remodeling, including the 3 most common surface treatments; fibermesh, sintered beads, and plasma spray coatings. Recently added to these are porous metal surfaces, which have increased porosity and optimal pore sizes when compared with titanium fibermesh. The most studied of these materials is the titanium fibermesh fixation surface, which has demonstrated a mechanical failure rate of 1% at 10 to 15 years. This technology utilizes the diffusion bonding process to attach fiber metal pads to a titanium substrate using heat and pressure. The sintered bead fixation surface offers a porous coating of various sizes of spherical beads, achieved by the sintering process, and has been shown to provide long-term fixation. While there are less long-term published data regarding the titanium plasma spray surface, its early results have provided evidence of its durability, even in the face of significant osteolysis. The most recently added alternative fixation surface is porous tantalum metal, which offers potentially greater bone ingrowth and bone graft incorporation due to its high porosity (80%) and low modulus of elasticity (3 MPa). Porous tantalum implants have shown early favorable clinical results and have

  11. Acoustic Emission Methodology to Evaluate the Fracture Toughness in Heat Treated AISI D2 Tool Steel

    NASA Astrophysics Data System (ADS)

    Mostafavi, Sajad; Fotouhi, Mohamad; Motasemi, Abed; Ahmadi, Mehdi; Sindi, Cevat Teymuri

    2012-10-01

    In this article, fracture toughness behavior of tool steel was investigated using Acoustic Emission (AE) monitoring. Fracture toughness ( K IC) values of a specific tool steel was determined by applying various approaches based on conventional AE parameters, such as Acoustic Emission Cumulative Count (AECC), Acoustic Emission Energy Rate (AEER), and the combination of mechanical characteristics and AE information called sentry function. The critical fracture toughness values during crack propagation were achieved by means of relationship between the integral of the sentry function and cumulative fracture toughness (KICUM). Specimens were selected from AISI D2 cold-work tool steel and were heat treated at four different tempering conditions (300, 450, 525, and 575 °C). The results achieved through AE approaches were then compared with a methodology proposed by compact specimen testing according to ASTM standard E399. It was concluded that AE information was an efficient method to investigate fracture characteristics.

  12. Effect of acetabular orientation on stress distribution of highly cross-linked polyethylene liners.

    PubMed

    Lam, Luthan; Drew, Timothy; Boscainos, Petros

    2013-11-01

    Several case reports have documented the fracture of highly cross-linked polyethylene (HCLPE) liners used in total hip arthroplasty (THA). Although uncommon, fractured liners result in considerable morbidity for patients and require revision surgery. One postulated mechanism that leads to this type of implant failure is malorientation of the acetabular component. The purpose of this study was to investigate the effect of acetabular orientation on the stress distribution of HCLPE liners used in THA by means of finite element analysis. Three-dimensional models of a commonly used HCLPE liner were created corresponding to 12 different acetabular component orientations (inclination ranging from 20° to 70° and version ranging from 20° of retroversion to 40° of anteversion). A static stress analysis of the finite element models was performed under conditions simulating peak gait loads. The results of the analysis revealed that excessive inclination and extremes of version were associated with an increase in peak stress magnitudes. The locations of peak stress also were found to lie within the rim notch and locking ring groove regions, which were consistent with the fracture locations reported in published case reports. Therefore, the acetabular component should be oriented carefully during implantation to reduce the risk of rim loading and subsequent liner fracture. In addition, an alternative liner design may further help reduce stress risers and risk of fracture. PMID:24200436

  13. Acetabular Reconstruction in Total Hip Arthroplasty

    PubMed Central

    Santhanam, Siva Swaminathan; Choi, Jung Woo

    2016-01-01

    The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component selection is mostly based on the amount of bone loss present. In the presence of combined cavitary and segmental defects without superior acetabular coverage, reconstructions with a structural acetabular allograft protected by a cage or a custom-made triflange cage have been one of preferred surgical options. The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent rerevision surgery to a certain extent. But high complication rates have been reported including aseptic loosening, infection, dislocation and metal failure. On the other hand, recent literature is reporting satisfactory outcomes with the use of modular augments combined with a hemispherical shell for major acetabular defect. Highly porous metals have been introduced for clinical use in arthroplasty surgery over the last decade. Their higher porosity and surface friction are ideal for acetabular revision, optimizing biological fixation. The use of trabecular metal cups in acetabular revision has yielded excellent clinical results. This article summarizes author's experience regarding revision acetabular reconstruction options following failed hip surgery including arthroplasty. PMID:27536638

  14. Acetabular Reconstruction in Total Hip Arthroplasty.

    PubMed

    Shon, Won Yong; Santhanam, Siva Swaminathan; Choi, Jung Woo

    2016-03-01

    The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component selection is mostly based on the amount of bone loss present. In the presence of combined cavitary and segmental defects without superior acetabular coverage, reconstructions with a structural acetabular allograft protected by a cage or a custom-made triflange cage have been one of preferred surgical options. The use of a cage or ring over structural allograft bone for massive uncontained defects in acetabular revision can restore host bone stock and facilitate subsequent rerevision surgery to a certain extent. But high complication rates have been reported including aseptic loosening, infection, dislocation and metal failure. On the other hand, recent literature is reporting satisfactory outcomes with the use of modular augments combined with a hemispherical shell for major acetabular defect. Highly porous metals have been introduced for clinical use in arthroplasty surgery over the last decade. Their higher porosity and surface friction are ideal for acetabular revision, optimizing biological fixation. The use of trabecular metal cups in acetabular revision has yielded excellent clinical results. This article summarizes author's experience regarding revision acetabular reconstruction options following failed hip surgery including arthroplasty. PMID:27536638

  15. Protocols for treating the postoperative pain of fractures in Dutch hospitals

    PubMed Central

    Ossendorp, Rikkert; Forouzanfar, Tymour; Ashton-James, Claire E; Bloemers, Frank

    2013-01-01

    Introduction Every year, over 260,000 patients in the Netherlands are diagnosed with a traumatic fracture. Many patients are treated surgically and need postoperative treatment of pain. Research suggests postoperative pain is often under-treated, leaving a significant proportion of patients in moderate to severe postoperative pain. Specialized, evidence-based pain-management protocols offer patients the best possible pain management, and significantly reduce the risk of pain-related health complications. Objective Our objective was to review the range of postoperative pain protocols that are currently being used to treat postoperative fracture pain within the Netherlands, and investigate whether a specialized, evidence-based protocol for treating postoperative fracture pain exists within this sample. Methods A written request for the protocol currently being used for the treatment of postoperative pain following the surgical treatment of a fracture was sent to 101 Dutch hospital departments. The administration and dosage of pain medications used during postoperative pain management were then identified and summarized. Results Of the contacted hospitals, 57% sent in protocols; 45% of these were eligible for analysis. All of the departments sent a general or acute pain protocol rather than a specialized protocol for the treatment of postoperative pain associated with the surgical treatment of fractures. A total of 22 different analgesics were used for pain management in 135 different administration schemes. Paracetamol, diclofenac, and morphine were used in the majority of protocols. Medication was given via oral, rectal, intravenous, subcutaneous, intramuscular, and epidural routes, amongst others. Conclusion No specialized, evidence-based protocols for the treatment of postoperative fracture pain were found in this Dutch sample. A wide variety of medications, dosages, and administration schemes were used to manage postoperative pain following the surgical treatment

  16. Retrospective review of 234 scaphoid fractures and nonunions treated with arthroscopy for union and complications.

    PubMed

    Slade, J F; Gillon, T

    2008-01-01

    The purpose of this paper is to retrospectively review 234 consecutive cases of scaphoid fractures and nonunions treated using arthroscopy with the dorsal percutaneous implantation of a headless compression screw for healing and complications. Solid union of fracture is determined by CT scan. We identified 126 acute injuries, including 65 proximal pole fractures; 67 grossly displaced fractures; 12 trans-scaphoid perilunate dislocations including four trans-scaphoid trans-capitate fractures; and ten combined scaphoid and distal radius fractures. 108 scaphoid nonunions were identified. 98 were correctly aligned and ten had a humpback deformity which was correctable using arthroscopic assisted reduction techniques at the time of surgery. 82 presented with a fracture gap 2mm or greater requiring percutaneous bone grafting. 12 cases of avascular necrosis (AVN) were identified by MRI. 20 nonunions had surgery performed at other institutions. The mean time to surgery for the nonunions was 20 months. 99% union rate of acute scaphoid fractures was obtained by 12 weeks, as determined by CT scan. Two complications were identified (3%). One case of delayed healing was identified. this delayed union was treated with percutaneous bone grafting and continued on to heal uneventfully. The other complication was a case of volar trans-scaphoid peri-lunate dislocation. While the fracture healed, the patient developed a traumatic dislocation requiring a capitate-lunate arthrodesis. Treatment of scaphoid nonunions resulted in ten cases of delayed healing, which were treated with repeat percutaneous bone grafting. This represented a 9% complication rate. of the ten cases of delayed unions that were re-bone grafted, four failed to heal by nine months. This resulted in a 96% union rate of our nonunion group by nine months. when acute fracture healing was compared to nonunions the average healing of acute fractures as determined by CT scanning measuring trabecular bridging was 12 weeks

  17. Influence of remaining dentin wall thickness on the fracture strength of endodontically treated tooth

    PubMed Central

    Haralur, Satheesh B.; Al-Qahtani, Ali Saad; Al-Qarni, Marie Mohammed; Al-Homrany, Rami Mohammed; Aboalkhair, Ayyob Ehsan

    2016-01-01

    Background: Remaining dentin wall thickness may influence the fracture resistance of tooth. Aims: To investigate the effect of various coronal dentin wall widths on the fracture strength of root canal treated teeth. Materials and Methods: Fifty recently extracted single canal mandibular premolars were used for the study. Ten unrestored teeth were used as control (Group 1); remaining teeth were root canal treated and divided into four groups (n = 10). The Groups 2a, 2b and 3a, 3b were having 2.5 mm, 1.5 mm remaining dentin with and without post, respectively. The samples fracture resistance was tested under the universal testing machine. The data were analyzed with one-way ANOVA and post-hoc Tukey test for comparative evaluation. Results: The mean fracture strength observed in Group 1 was (29.75 Mpa) followed by Group 2a (28.97 Mpa), Group 2b (27.70 Mpa), Group 3a (23.39 Mpa), and Group 3b (16.38 Mpa). There was no statistically significant difference between control and Groups 2a and 2b with P > 0.05. The post contributed significantly for fracture resistance in Group 3a. Conclusion: The endodontic post is not required in root canal treated teeth >2.5 mm coronal dentin wall width while the post is essential for a tooth with <1.5 mm dentin wall width to improve fracture resistance. PMID:26957796

  18. Factors Associated with Significant Ocular Injury in Conservatively Treated Orbital Fractures

    PubMed Central

    Layton, Christopher J.

    2014-01-01

    Purpose. To determine factors associated with the presence of significant ocular injury in subjects with orbital fractures. Subjects. A consecutive prospective cohort of 161 patients presenting to a general tertiary referral hospital with orbital fractures and undergoing initial conservative treatment was identified. Subjects were assessed at time of injury for the need for emergency surgery, and those initially treated conservatively were subsequently followed up by the Ophthalmology Department to assess for ocular injury requiring ophthalmic management at 1–7 days after injury. Associations between ocular injury and age, sex, visual acuity, presence of blowout fracture, extent of orbital involvement, and presence of distant facial fractures were assessed. Results. 142 male (average age of 32 [95% CI 30–35]) and 19 female (average age of 49 [95% CI 39–59]) subjects were identified. 17 subjects were diagnosed with significant ocular injury. Ocular injury was significantly associated with LogMAR VA worse than 0.2 (OR 49 [95% CI 11–217, P < 0.0001]), but no relationship was noted for age, sex, presence of blowout fracture, extent of fractures, or presence of distal facial fractures. LogMAR visual acuity worse than or equal to 0.2 had a 98% negative predictive value for ocular injury in the setting of orbital fractures. Conclusions. Demographic and nonophthalmic fracture characteristics were not useful predictors of ocular injury in orbital fractures. LogMAR visual acuity worse than or equal to 0.2 is a highly sensitive and useful guide of the need for ophthalmic referral in subjects with orbital fractures. PMID:25580279

  19. Factors associated with significant ocular injury in conservatively treated orbital fractures.

    PubMed

    Layton, Christopher J

    2014-01-01

    Purpose. To determine factors associated with the presence of significant ocular injury in subjects with orbital fractures. Subjects. A consecutive prospective cohort of 161 patients presenting to a general tertiary referral hospital with orbital fractures and undergoing initial conservative treatment was identified. Subjects were assessed at time of injury for the need for emergency surgery, and those initially treated conservatively were subsequently followed up by the Ophthalmology Department to assess for ocular injury requiring ophthalmic management at 1-7 days after injury. Associations between ocular injury and age, sex, visual acuity, presence of blowout fracture, extent of orbital involvement, and presence of distant facial fractures were assessed. Results. 142 male (average age of 32 [95% CI 30-35]) and 19 female (average age of 49 [95% CI 39-59]) subjects were identified. 17 subjects were diagnosed with significant ocular injury. Ocular injury was significantly associated with LogMAR VA worse than 0.2 (OR 49 [95% CI 11-217, P < 0.0001]), but no relationship was noted for age, sex, presence of blowout fracture, extent of fractures, or presence of distal facial fractures. LogMAR visual acuity worse than or equal to 0.2 had a 98% negative predictive value for ocular injury in the setting of orbital fractures. Conclusions. Demographic and nonophthalmic fracture characteristics were not useful predictors of ocular injury in orbital fractures. LogMAR visual acuity worse than or equal to 0.2 is a highly sensitive and useful guide of the need for ophthalmic referral in subjects with orbital fractures. PMID:25580279

  20. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

    PubMed Central

    2012-01-01

    Background and purpose Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during internal fixation, and the introduction of locking-plate osteosynthesis may lead to improved outcome. We evaluated the outcome of Vancouver type B1 and C PFFs treated by locking-plate osteosynthesis, by assessing rates of fracture union and reoperations and by analyzing failure cases. Patients and methods From 2002 through 2011, 58 consecutive patients (60 fractures) with low-energy PFF around or below a stable femoral stem, i.e. Vancouver type B1 and C fractures, underwent osteosynthesis with a locking plate. All patients had a total hip replacement (THR). They were followed up clinically and radiographically, with 6 weeks between visits, until fracture union or until death. Fracture union was evaluated 6 months postoperatively. Results At a median follow-up time of 23 (0–121) months after PFF, 8 patients (8 fractures) had been reoperated due either to infection (n = 4), failure of fixation (n = 3), or loosening of the femoral stem (n = 1). All the patients who had been followed up for at least 6 months—and who did not undergo reoperation or die—went on to fracture union (n = 43). Interpretation Locking-plate osteosynthesis of periprosthetic Vancouver type B1 and C fractures gives good results regarding fracture union. It appears that spanning of the prosthesis to avoid stress-rising areas is important for successful treatment. Infection is the major cause of failure. PMID:23140109

  1. UNSTABLE FEMORAL FRACTURES TREATED WITH TITANIUM ELASTIC INTRAMEDULLARY NAILS, IN CHILDREN

    PubMed Central

    Soni, Jamil Faissal; Schelle, Gisele; Valenza, Weverley; Pavelec, Anna Carolina; Souza, Camila Deneka Arantes

    2015-01-01

    Objective: To evaluate the indications, epidemiology, associated lesions, complications and prognosis among children with unstable femoral diaphysis fractures who were treated with titanium elastic intramedullary nails. Method: This was a retrospective analysis on 24 patients aged 5-12 years with unstable femoral diaphysis fractures who underwent surgical treatment with elastic titanium intramedullary nails at the Cajuru University Hospital, Curitiba-PR, between April 2002 and March 2008, with a minimum follow-up of 36 months. The epidemiological data, angular deviations, leg shortening and bone consolidation were evaluated. Results: The medical files of 113 cases operated between April 2002 and March 2008 were reassessed. From these, 24 cases of unstable femoral diaphysis fractures treated with elastic titanium intramedullary nails with retrograde insertion were included in the study. There were two bilateral fractures and two exposed fractures. Seven patients were female and 17 were male, and the mean age was 8.3 years. The following were presented at the end of the study: shortening, varus or valgus displacement, final retrocurvatum or antecurvatum of zero, and absence of delayed consolidation or pseudarthrosis. Conclusions: The elastic titanium intramedullary nails were easily placed and removed. We believe that using elastic titanium intramedullary nails is a good option for fixation of unstable femoral fractures in children. PMID:27047868

  2. Risk of Hip Fracture Associated with Untreated and Treated Chronic Hepatitis B Virus Infection

    PubMed Central

    Byrne, Dana D.; Newcomb, Craig W.; Carbonari, Dena M.; Nezamzadeh, Melissa S.; Leidl, Kimberly B. F.; Herlim, Maximilian; Yang, Yu-Xiao; Hennessy, Sean; Kostman, Jay R.; Leonard, Mary B.; Localio, A. Russell; Lo Re, Vincent

    2014-01-01

    Background & Aims Chronic hepatitis B (CHB) infection is associated with reduced bone mineral density, but its association with fractures is unknown. Our objectives were to determine whether untreated or treated CHB-infected persons are at increased risk for hip fracture compared to uninfected persons. Methods We conducted a cohort study among 18,796 untreated CHB-infected, 7,777 treated CHB-infected, and 979,751 randomly sampled uninfected persons within the U.S. Medicaid populations of California, Florida, New York, Ohio, and Pennsylvania (1999 – 2007). CHB infection was defined by two CHB diagnoses recorded >6 months apart and was classified as treated if a diagnosis was recorded and antiviral therapy was dispensed. After propensity score matching of CHB-infected and uninfected persons, Cox regression was used to estimate hazard ratios (HRs) with 95% confidence intervals (CIs) of incident hip fracture in: 1) untreated CHB-infected versus uninfected, and 2) treated CHB-infected versus uninfected patients. Results Untreated CHB-infected patients of black race had a higher rate of hip fracture than uninfected black persons (HR, 2.55 [95% CI, 1.42 – 4.58]). Compared to uninfected persons, relative hazards of hip fracture were increased for untreated white (HR, 1.26 [95% CI, 0.98 – 1.62]) and Hispanic (HR, 1.36 [95% CI, 0.77 – 2.40]) CHB-infected patients, and treated black (HR, 3.09 [95% CI, 0.59 – 16.22) and white (HR, 1.90 [95% CI, 0.81 – 4.47]) CHB-infected patients, but these associations were not statistically significant. Conclusions Among U.S. Medicaid enrollees, untreated CHB-infected patients of black race had a higher risk of hip fracture than uninfected black persons. PMID:24713185

  3. A technique to remove a well-fixed titanium-coated rm acetabular cup in revision hip arthroplasty

    PubMed Central

    2011-01-01

    A major concern during revision hip arthroplasty is acetabular bone loss and bleeding during the extraction of well-fixed cementless acetabular cup, because no interface exists between the host bone and the cup. Forceful removal of such component using curved gouges and osteotomes often leads to extended bone loss and compromises reimplantation of a new socket. In the following case report, we removed a well-fixed polyethylene titanium-coated RM acetabular cup with 20 years of follow-up, by significant wear of the polyethylene layer. The isoelastic femoral stem was also removed by mechanical failure. We report a technique for removal of the cementless acetabular cup using powered acetabular reamers. The RM cup was sequentially reamed and when the polyethylene layer was thin enough, the remaining cup was removed easily by hand tools. The acetabular bone stock is preserved and the risks of bone fractures and bleeding are minimized. To our knowledge, these principles were applied only in cemented cups. We have used this technique in 10 cases with excellent results and no complications were noted. This is a simple, reproducible, non-costly, non-timing consuming, safe and successful technique to remove well-fixed titanium-coated RM acetabular cups. PMID:21689456

  4. Use of 2 column screws to treat transcondylar distal humeral fractures in geriatric patients.

    PubMed

    Paryavi, Ebrahim; O'Toole, Robert V; Frisch, Harold M; Andersen, Romney C; Eglseder, W Andrew

    2010-12-01

    We describe fixation of transcondylar distal humeral fractures with column screws in geriatric patients and review our initial results. We conducted a retrospective review of a prospectively collected database at a Level I trauma center. Six patients met inclusion criteria of age older than 65 years and treatment of minimally or nondisplaced transcondylar distal humeral fracture with column screws only. All were closed fractures with no associated nerve injuries. One patient was lost to follow-up. The mechanism of injury was low-energy fall for the 5 remaining patients (average age, 74 y; age range, 70 to 83 y; average follow-up duration, 10.6 wk). One patient had a traumatic brain injury and a contralateral metacarpal fracture that was treated with internal fixation. The remaining 4 patients sustained isolated distal humeral fractures. No complications were noted, and all fractures healed at an average radiographic union time of 7.2 weeks. Average range of motion was 22 degrees extension [95% CI (-1.47, 45.47)], 114 degrees flexion [95% CI (89.4, 138.6)], and 92 degrees arc of motion [95% CI (58.68, 125.38)]. Treatment of select transcondylar distal humeral fractures with column screws in geriatric patients provides an option for stable fixation that allows early range of motion with minimal surgical morbidity. PMID:21107215

  5. Fracture resistance of endodontically treated single rooted premolars restored with Sharonlay: An in vitro study

    PubMed Central

    Sharath Chandra, S. M.; Agrawal, Nishtha; Sujatha, I.; Sivaji, K.

    2016-01-01

    Aims: The aim of this study is to compare in vitro the fracture resistance of the endodontically treated tooth restored with a novel design Sharonlay, with the two component restorative method, i.e., post with separate onlay, and onlay without post. Subjects and Methods: 45 single-rooted mandibular second premolars were taken, and root canal treatment was performed. Teeth were then randomly divided into three groups (n = 15) based on the type of restoration given: Group I - metal onlay with cast post extension (Sharonlay), Group II - metal onlay with prefabricated metal post (Mani post system), Group III - metal onlay over endodontically treated tooth obturated with Gutta-percha (control group). Fracture resistance was checked using the Instron universal testing machine and the fracture patterns were analyzed. Results: According to the values recorded, Group I showed maximum mean fracture resistance followed by Groups II and III. Statistically significant difference was found between Groups I and II and Groups I and III and statistically significant difference was found between Groups II and III. Conclusion: A single unit component Sharonlay, gives higher fracture resistance to a premolar as compared to (a) metal onlay with prefabricated metal post and (b) metal onlay over endodontically treated tooth. PMID:27217643

  6. Nonoperatively treated forearm shaft fractures in children show good long-term recovery

    PubMed Central

    Sinikumpu, Juha-Jaakko; Victorzon, Sarita; Antila, Eeva; Pokka, Tytti; Serlo, Willy

    2014-01-01

    Background and purpose — The incidence of forearm shaft fractures in children has increased and operative treatment has increased compared with nonoperative treatment in recent years. We analyzed the long-term results of nonoperative treatment. Patients and methods — We performed a population-based age- and sex-matched case-control study in Vaasa Central Hospital, concerning fractures treated in the period 1995–1999. There were 47 nonoperatively treated both-bone forearm shaft fractures, and the patients all participated in the study. 1 healthy control per case was randomly selected and evaluated for comparison. We analyzed clinical and radiographic outcomes of all fractures at a mean of 11 (9–14) years after the trauma. Results — The main outcome, pronosupination of the forearm, was not decreased in the long term. Grip strength was also equally as good as in the controls. Wrist mobility was similar in flexion (85°) and extension (83°) compared to the contralateral side. The patients were satisfied with the outcome, and pain-free. Radiographally, 4 cases had radio-carpal joint degeneration and 4 had a local bone deformity. Interpretation — The long-term outcome of nonoperatively treated both-bone forearm shaft fractures in children was excellent. PMID:25238437

  7. Evaluation of Tibial Condyle Fractures Treated with Ilizarov Fixation, A Prospective Study

    PubMed Central

    Reddy R, Sandeep; Shah, Harshad M; Golla, Dinesh Kumar; Ganesh D J, Niranthara; Kumar P, Ashok

    2014-01-01

    Background: Tibial plateau fractures are associated with significant soft tissue injuries which increases the risks of complications and must be considered when managing tibial plateau fractures. Various modalities of treatment are available for treatment of these fractures but Ilizarov fixation has a special advantage over others. Review of literature shows many studies of Ilizarov fixation in the treatment of tibial plateau fractures with variable results. Aim of our study was to evaluate tibial condyle fractures treated by Ilizarov fixation. Materials and Methods: Study included 43 patients with Schatzker type II and above tibial plateau fractures treated by ilizarov fixation. Standard trauma evaluation, a meticulous musculoskeletal and neurologic examination was carried out. All patients underwent Ilizarov fixation by same team of surgeons. Clinicoradilogical assessment of the patients carried out at regular intervals. Results: Our study included 43 cases of tibial plateau of various types except type I. Mean time for radiological union was 24.51 wk (range 15 to 32 wk). Mean fixator period was 26.6 wk( 16-34 wk). The functional results were measured by Lyshom’s and Hohl and Luck score. The mean Lyshom’s score was at the end of one year was 82.16. At end of one year by Hohl and Luck grading 11 patients had fair, 23 had good and 9 had excellent results. Conclusion: High energy tibial plateau fractures can be definitively treated with Ilizarov external fixation. Treatment with this method gives good union rates and less risk of infection. Closed reduction, minimal soft tissue damage and early mobilization are the key to low complications. PMID:25584250

  8. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite

    PubMed Central

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    Summary Aim To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Methods Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05). Results No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. Conclusions No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations. PMID:27486505

  9. Placement of the acetabular component.

    PubMed

    Beverland, D E; O'Neill, C K J; Rutherford, M; Molloy, D; Hill, J C

    2016-01-01

    Ideal placement of the acetabular component remains elusive both in terms of defining and achieving a target. Our aim is to help restore original anatomy by using the transverse acetabular ligament (TAL) to control the height, depth and version of the component. In the normal hip the TAL and labrum extend beyond the equator of the femoral head and therefore, if the definitive acetabular component is positioned such that it is cradled by and just deep to the plane of the TAL and labrum and is no more than 4mm larger than the original femoral head, the centre of the hip should be restored. If the face of the component is positioned parallel to the TAL and psoas groove the patient specific version should be restored. We still use the TAL for controlling version in the dysplastic hip because we believe that the TAL and labrum compensate for any underlying bony abnormality. The TAL should not be used as an aid to inclination. Worldwide, > 75% of surgeons operate with the patient in the lateral decubitus position and we have shown that errors in post-operative radiographic inclination (RI) of > 50° are generally caused by errors in patient positioning. Consequently, great care needs to be taken when positioning the patient. We also recommend 35° of apparent operative inclination (AOI) during surgery, as opposed to the traditional 45°. PMID:26733639

  10. Effect of Different Instrumentation Techniques on Vertical Root Fracture Resistance of Endodontically Treated Teeth

    PubMed Central

    Tavanafar, Saeid; Karimpour, Azadeh; Karimpour, Hamideh; Mohammed Saleh, Abdulrahman; Hamed Saeed, Musab

    2015-01-01

    Statement of the Problem Vertical root fractures are catastrophic events that often result in tooth extraction. Many contributing factor are associated with increasing incidence of vertical root fracture. Root canal preparation is one of the predisposing factors which can increase the root susceptibility to vertical fracture. Purpose The aim of this study was to compare the effects of three different instrumentation techniques on vertical root fracture resistance of endodontically treated teeth. Materials and Methods In this study, 120 freshly extracted mandibular premolar teeth of similar dimensions were decoronated and randomly divided into control (n=30), nickel-titanium hand K-file (HF, n=30), BioRaCe rotary file (BR, n=30), and WaveOne reciprocating single-file (WO, n=30) groups. After cleaning and shaping the root canals, AH26 was used as canal sealer, and obturation was completed using the continuous wave technique. The root canals were embedded vertically in standardised autopolymerising acrylic resin blocks, and subjected to a vertical load to cause vertical root fracture. The forces required to induce fractures were measured using a universal testing machine. ANOVA and Tukey’s post-hoc test were used to analyse the data. Results All experimental groups showed statistically significant reductions in fracture resistance as compared with the control group. There was a statistically significant difference between the HF and BR groups. The WO group did not differ significantly from the HF group or the BR group. Conclusion All three instrumentation techniques caused weakening of the structure of the roots, and rendered them susceptible to fracture under lesser load than unprepared roots. The fracture resistance of roots prepared with the single-file reciprocating technique was similar to that of those prepared with NiTi hand and rotary instrumentation techniques. PMID:26106635

  11. Outcome of unstable fractures of metacarpal and phalangeal bones treated by bone tie

    PubMed Central

    Kamath, Jagannath B; Jayasheelan, Nikil; Savur, Amaranth; Mathews, Rejith

    2016-01-01

    Background: Unstable fractures of the metacarpal and phalangeal bones of the hand need surgical stabilization which should be rigid enough for early active mobilization. Conventional methods of open reduction and stabilization in the form of composite fixation or screws with or without plates have served the purpose but can be definitely improvised addressing both biological and mechanical principles of fixation. Materials and Methods: 34 patients (29 males and 5 females) with an average age of 32 years (range 10–64 years) with unstable fractures of the metacarpal and phalangeal bones of hand who were treated with the modified bone tie between June 2009 and June 2013 were included in this study. 42 fractures, involving the 31 metacarpals and 11 phalanges were included. We have not used this technique in fractures involving the terminal phalanges. Thirty nine of the fractures were treated with K-wires along with the modified bone tie, whereas the other two cases were treated with modified bone tie alone and in one case the bone tie has been used along with the external fixator. The nature of injuries were Road Traffic Accident (n = 24), domestic/industrial injuries (n = 8) and blast (n = 2) injuries. Etiology was crush (n = 24), blunt (n = 7) and incised (n = 3) injuries, respectively. Twenty seven patients were involved with single fractures (either metacarpal or the phalanges), 6 patients had two fractures (both metacarpals or phalanges or one each of metacarpal and phalanx), and 1 patient had three fractures in this study. Dominant hand was involved in 14 patients (40%). Results: We achieved excellent to good results in 83% of 42 fractures within an average period of 10 weeks. Postoperative grip strength of 85% was achieved with in an average period of 12 weeks. Twenty six (20 metacarpals and 6 phalanges) of the 42 fractures regained >85% of the total active movements (TAMs) compared to the contralateral side were considered excellent results. All patients were

  12. Fracture resistance of endodontically treated teeth restored with ceramic inlays and different base materials.

    PubMed

    Saridag, Serkan; Sari, Tugrul; Ozyesil, Atilla Gokhan; Ari Aydinbelge, Hale

    2015-01-01

    This study evaluated the fracture resistance of endodontically treated teeth restored with different base materials and mesioocclusal-distal (MOD) ceramic inlays. Fifty mandibular molars were assigned into five groups (n=10 per group). Group1 (control) comprised intact molar teeth without any treatment. Teeth in other groups were subjected to root canal treatment and restored with MOD ceramic inlays on different base materials. In Group 2, base material was zinc phosphate cement; Group 3's was glass ionomer cement; Group 4's was composite resin, and Group 5's was composite resin reinforced with fiber. Finally, a continuous occlusal load was applied until fracture occurred. Mean fracture resistance of Group 1 (3,027 N) was significantly higher than the other groups (890, 1,070, 1,670, 1,226 N respectively). Fracture resistance of Group 4 was statistically comparable with Group 5 and significantly higher than Groups 2 and 3 (p<0.05; Tukey's HSD). Use of different base materials under ceramic inlay restorations could affect the fracture resistance of endodontically treated teeth. PMID:25740162

  13. The functional results of tibial shaft fractures treated with intramedullary nail compressed by proximal tube.

    PubMed

    Karaarslan, Ahmet Adnan; Acar, Nihat; Aycan, Hakan; Sesli, Erhan

    2016-04-01

    Nailing of tibial shaft fractures is considered the gold standard surgical method by many surgeons. The aim of this retrospective study was to investigate and compare the clinical outcome of tibial shaft fractures treated with intramedullary nails compressed by proximal tube and conventional intramedullary interlocking nails. Fifty-seven patients with tibial shaft fractures, treated with intramedullary nails compressed by proximal tube (n = 32) and the conventional interlocking nails (n = 25), were reviewed. All fractures except for one were united without any additional surgical intervention in the proximal compression tube nail group, whereas in the conventional interlocking nail group, six patients needed dynamization surgery (p = 0.005) and three cases of nonunion were recorded. In the proximal compression tube nail group, faster union occurred in 20 ± 2 (16-24) weeks (mean ± SD; range) without failure of locking screws and proximal nail migration, whereas in the conventional interlocking nail group, union occurred in 22 ± 2.5 (17-27) weeks (p = 0.001) with two failures of locking screws and two proximal nail migration. The proximal compression tube nail system is safer than the conventional nailing methods for the treatment for transverse and oblique tibial shaft fractures with a less rate of nonunion, proximal locking screw failure and proximal nail migration. PMID:26837377

  14. Inter- and intra-observer agreement of the AO classification for operatively treated distal radius fractures.

    PubMed

    van Buijtenen, Jesse M; van Tunen, Mischa L C; Zuidema, Wietse P; Heilbron, Emile A; de Haan, Jeroen; de Vet, Henrica C W; Derksen, Robert J

    2015-11-01

    The reproducibility of the AO classification for distal radius fractures remains a topic of debate. Previous studies showed variable reproducibility results. Important treatment decisions depend on correct classification, especially in comminuted, intra-articular fractures. Therefore, reliable reproducibility results need to be undisputedly determined. Hence, the study objective was to assess inter- and intra-observer agreement of the AO classification for operatively treated distal radius fractures. A database of 54 radiographs of all AO types (A, B and C) and groups (A2-3, B1-3, and C1-3) of distal radius fractures was assessed in twofold. Likewise, a subset of 152 radiographs of solely C-type groups (C1-3) was assessed. All fractures were classified by six observers with different experience levels: three consultant trauma surgeons, one sixth-year trauma surgery resident, a consultant trauma radiologist, and an intern with limited experienced. The inter-observer agreement of both main types and groups was moderate (κ = 0.49 resp. κ = 0.48) in combination with a good intra-observer agreement (κ = 0.68 resp. κ = 0.70). The inter-observer agreement of the subset C-type fractures group was fair (κ = 0.27) with moderate intra-observer agreement (κ = 0.43). According to these results, the reproducibility of the AO classification of main types and groups of distal radius fractures based on conventional radiographs is insufficient (κ < 0.50), especially at group level of C-type fractures. PMID:26614083

  15. Intraoperative Computed Tomography Navigation for Transpedicular Screw Fixation to Treat Unstable Thoracic and Lumbar Spine Fractures

    PubMed Central

    Lee, Ching-Yu; Wu, Meng-Huang; Li, Yen-Yao; Cheng, Chin-Chang; Hsu, Chu-Hsiang; Huang, Tsung-Jen; Hsu, Robert Wen-Wei

    2015-01-01

    Abstract Transpedicular screw (TPS) fixation in unstable thoracic and lumbar (TL) spine fractures remains technically difficult because of destroyed anatomical landmarks, unstable gross segments, and discrepancies in anatomic orientation using conventional anatomic landmarks, fluoroscopic guidance, or computed tomography (CT)-based navigation. In this study, we evaluated the safety and accuracy of TPS placement under intraoperative computed tomography (iCT) navigation in managing unstable TL spine fractures. From 2010 to 2013, we retrospectively reviewed the Spine Operation Registry records of patients who underwent posterior instrumented fusion to treat unstable TL spine fractures via the iCT navigation system. An unstable spine fracture was identified as AO/Magerl classification type B or type C. In all, 316 screws in 37 patients with unstable TL spine fractures were evaluated and involved 7 thoracic, 23 thoracolumbar junctional, and 7 lumbar fractures. The accuracy of TPS positioning in the pedicle without breach was 98% (310/316). The average number of iCT scans per patient was 2.1 (range 2–3). The average total radiation dose to patients was 15.8 mSv; the dose per single level exposure was 2.7 mSv. The TPS intraoperative revision rate was 0.6% (2/316) and no neurovascular sequela was observed. TPS fixation using the iCT navigation system obtained a 98% accuracy in stabilizing unstable TL spine fractures. A malplaced TPS could be revised during real-time confirmation of the TPS position, and no secondary operation was required to revise malplaced screws. The iCT navigation system provides accurate and safe management of unstable TL spine fractures. In addition, operating room personnel, including surgeons and nurses, did not need to wear heavy lead aprons as they were not exposed to radiation. PMID:25997042

  16. Retrospective study of mandibular angle fractures treated with three different fixation systems

    PubMed Central

    Bhatt, Krushna; Arya, Satyavrat; Bhutia, Ongkila; Pandey, Sandeep; Roychoudhury, Ajoy

    2015-01-01

    Aim: To evaluate the outcomes of mandibular angle fractures treated with metal 2.0 mm locking, metal 2.0 mm nonlocking, and 2.5 mm resorbable systems. Study Design: Retrospective cohort study. Materials and Methods: Trauma records were screened for linear angle fractures treated with open-reduction and internal semi-rigid fixation with single metal/bioresorbable plates, and baseline variables were tabulated. The outcome variable was the presence or absence of any complication. Statistical Analysis Used: The Fisher's exact test and analysis of covariance (ANCOVA) using STATA 11. Results: A total of 60 case records of over four years were included. The mean age of the patients was 27.4 (SD 9.7) years. Fifty-five were male and five female. There were 20 nonlocking and 16 locking metal miniplates and 24 bioresorbable plates. In 55 (91.6%) cases there was a third molar in the fracture line. In 51/55 (92.7%) cases the third molar was retained. In seven patients postoperative complications were seen. There was no difference between the complication rates of the three treatment groups. Infection was the most common complication followed by delayed union and hardware failure. Conclusions: This retrospective study found no difference in the complication rate when fractures of the mandibular angle were treated with locking or nonlocking miniplates or bioresorbable plates. PMID:26668450

  17. Uncomplicated crown fracture, complicated crown-root fracture, and horizontal root fracture simultaneously treated in a patient during emergency visit: a case report.

    PubMed

    Rajput, Akhil; Ataide, Ida; Fernandes, Marina

    2009-02-01

    Complicated crown fractures are not uncommon in cases of severe trauma or sports related injury. Such patients report with pain because of exposed pulp and need emergency care. Because of impaired function, esthetics, and phonetics, such patients are quite apprehensive during their emergency visit. Successful pain management with immediate restoration of function, esthetics, and phonetics should be the prime objective when handling such cases. This article describes immediate treatment of oblique crown root fracture of maxillary left central incisor, horizontal root fracture of maxillary left lateral incisor, and uncomplicated crown fracture of maxillary right central incisor. Maxillary left central incisor was treated with reattachment procedure using light-transmitting fiber post (D.T. Light Post; Bisco, Schaumburg, IL, USA); maxillary left lateral incisor subsequently healed after splinting for 7 weeks, and direct composite build-up was done on maxillary right central incisor. After 2 years, the reattached fragment had satisfying esthetics and excellent function and pulp was still vital in maxillary left lateral incisor and maxillary right central incisor. Various treatment modalities for traumatically injured incisors are shown in this article. PMID:19138637

  18. Postpartum osteoporosis and vertebral fractures in two patients treated with enoxaparin during pregnancy.

    PubMed

    Ozdemir, D; Tam, A A; Dirikoc, A; Ersoy, R; Cakir, B

    2015-01-01

    Postpartum osteoporosis (PPO) is a rare disease associated with pregnancy and lactation period. Here, we report severe PPO and multiple vertebral compression fractures in two patients treated with enoxaparin--low-molecular-weight heparin (LMWH)--throughout their pregnancy. A 34-year-old woman who has delivered her second baby 3 months ago presented with severe low-back pain. She was treated with enoxaparin 40 mg/day for 8 months during her pregnancy. Dual-energy X-ray absorptiometry (DEXA) showed low T- and Z-scores in lumbar (L) vertebras. In magnetic resonance imaging (MRI), severe height losses in thoracic (T) 12, L1, and L2 vertebras were detected. She was diagnosed to have severe PPO and multiple vertebral compression fractures and was prescribed risedronate 35 mg/week, calcium, and vitamin D. The other patient was a 36-year-old woman diagnosed with PPO and vertebral fractures at the third week postpartum. She was also treated with enoxaparin 60 mg/day during her pregnancy. Severe osteoporosis in L vertebras and height losses indicative for compression fractures in T5-8, T11-12, and L2-5 vertebras were detected by DEXA and MRI, respectively. She was treated with calcitonin 200 U/day, calcium, and vitamin D. These findings suggest that vertebral compression fractures and PPO may be one of the causes of severe back pain in postpartum patients. Treatment with LMWH during pregnancy might be considered as a new risk factor for this rare condition. PMID:25138263

  19. Computed tomography of thoracic and lumbar spine fractures that have been treated with Harrington instrumentation

    SciTech Connect

    Golimbu, C.; Firooznia, H.; Rafii, M.; Engler, G.; Delman, A.

    1984-06-01

    Twenty patients with fractures of the thoracic and lumbar spine underwent computed tomography (CT) following Harrington distraction instrumentation and a spinal fusion. CT was done to search for a cause of persistent cord or nerve root compression in those patients who failed to improve and completely recover their partial neurologic deficit (14 cases). The most common abnormality was the presence of residual bone fragments originating in the burst fracture of a vertebral body displaced posteriorly, into the spinal canal. In patients with complications in the late recovery period, CT found exuberant callus indenting the canal or lack of fusion of the bone grafts placed in the anterolateral aspect of the vertebral bodies. This experience indicates that CT is the modality of choice for spinal canal evaluation in those patients who fail to have an optimal clinical course following fractures of the thoracic and lumbar spine treated with Harrington rods.

  20. Chronic Bilateral Tibial Stress Fractures with Valgus Treated with Bilateral Intramedullary Nailing: A Case Report

    PubMed Central

    Dailey, Steven K; Archdeacon, Michael T.

    2014-01-01

    Introduction: Stress fractures are overuse injuries most commonly seen in athletes, military recruits, and individuals with endocrine abnormalities. It has been demonstrated that chronic cases of anterior tibial stress fractures refractory to conservative management respond well to intramedullary nailing. To our knowledge, only one report has been published concerning patients with bilateral tibial stress fractures treated with bilateral intramedullary nailing. All patients in the series were high-level athletes. We present the case of a non-athletic patient with chronic bilateral tibial stress fractures and associated deformity successfully treated with bilateral intramedullary nails. Case Report: A 23-year-old Caucasian female full-time student presented with chronic bilateral shin pain for approximately five years. She had failed an extensive regimen of conservative management. She was diagnosed with chronic bilateral tibial stress fractures based on history, physical examination, and radiologic findings. She subsequently underwent sequential intramedullary nailing of her tibiae. Both tibiae were in valgus alignment; however, this did not preclude nail placement. The nails deformed upon insertion into the sclerotic canals to conform to the deformation. Post operatively the tibiae united and patient was relieved of her symptoms. Conclusion: Bilateral intramedullary nailing of chronic bilateral tibial stress fractures should be considered as a treatment option for all patients, not just high-level athletes, who fail a trial of conservative management. Additionally, mild to moderate tibial malalignment does not necessarily preclude tibial nailing as the smaller nails placed in sclerotic canals will likely deform on insertion and conform to the canal. PMID:27298944

  1. Treating postmenopausal osteoporosis in women at increased risk of fracture - critical appraisal of bazedoxifene: a review.

    PubMed

    Vestergaard, Peter; Thomsen, Susanna Vid Streym

    2010-01-01

    Several categories of drugs to treat osteoporosis exist in the form of bisphosphonates, strontium, parathyroid hormone, and selective estrogen receptor modulators (SERM). Advantages and disadvantages exist for each category as some patients may, for example, not tolerate bisphosphonates for gastrointestinal side effects, and especially in women in whom osteoporosis is frequent, several options for treatment are needed. The objectives of this review were to critically appraise the effects of bazedoxifene on risk of fractures especially in women at high risk of fractures. A systematic literature search was conducted for studies, especially randomized controlled trials with fractures as end-points. Bazedoxifene is a new member of the SERM group. The literature search identified one randomized controlled trial with fractures as end-point. This was a 3-year randomized double-blind placebo controlled trial in which 7492 postmenopausal women aged 55 to 85 years were randomly allocated to 1) bazedoxifene (20 [n = 1886] or 40 [n = 1872] mg/day); 2) raloxifene (60 mg/day, n = 1849); or 3) placebo (n = 1885). The risk of vertebral fractures decreased with both 20 (HR 0.58, 95% CI 0.38 to 0.89) and 40 (HR 0.63, 95% CI 0.42 to 0.96) mg of bazedoxifene per day compared to placebo. There was no reduction in non-vertebral fractures. A subgroup of women with a priori high risk of fractures was identified post hoc. In this subgroup there was a reduction in the risk of non-vertebral fractures with the 20 mg dose of bazedoxifene compared to placebo (HR 0.50, 95% CI 0.28 to 0.90). In the 40 mg bazedoxifene group no significant reduction in non-vertebral fractures was seen in this subgroup (HR 0.70, 95% CI 0.40 to 1.20). In general post-hoc defined subgroup analyses should be interpreted with caution. However, the results indicate that bazedoxifene may be effective in preventing vertebral fractures in postmenopausal women with osteoporosis. PMID:21072279

  2. Severe open bite due to traumatic condylar fractures treated nonsurgically with implanted miniscrew anchorage.

    PubMed

    Yanagita, Takeshi; Adachi, Rie; Kamioka, Hiroshi; Yamashiro, Takashi

    2013-04-01

    This case report illustrates the use of miniscrews to treat a patient with an open bite caused by mandibular condylar fractures. The patient was 36 years old when she visited our hospital with a chief complaint of difficulty with chewing. She had suffered condylar and maxillary bone fractures in a traffic accident 6 months before her visit. She had an anterior open bite and Angle Class II molar relationships. Her mandibular midline was deviated to the right relative to the maxilla. The cephalometric analysis showed a skeletal Class II relationship. Titanium miniscrews were implanted in the bilateral maxillary buccal areas. The maxillary dentition was retracted and intruded by using elastomeric chains and miniscrews. After this treatment, an Angle Class I molar relationship was achieved, her overjet and overbite became ideal, and a good facial appearance was obtained. The total active orthodontic treatment period was 33 months. Treating an open bite with molar intrusion often leads to counterclockwise rotation of the mandible; however, in this patient, the mandible was moved anteriorly and upward. We believe that this movement was caused by the patient's condylar fractures and the subsequent remodeling. Although there was some relapse, our results suggest that implant anchorage is useful for correcting anterior open bites originating from condylar fractures. PMID:23540631

  3. In vitro study to compare impact fracture resistance of intact root-treated teeth.

    PubMed

    McDonald, A V; King, P A; Setchell, D J

    1990-11-01

    The aim of this in vitro study was to determine the effect on impact fracture resistance of three methods for restoration of root-treated lower incisor teeth with otherwise intact natural crowns. In a control group (Group I) laterally condensed gutta-percha filled the entire root canal, whereas part of the root filling was removed to enable insertion of a 1 mm diameter post in the other two groups. Stainless steel posts were placed in Group II and experimental carbon fibre reinforced carbon (CFRC) in Group III. A composite resin luting agent was used to lute the posts, and standardized composite resin restorations were placed in each access cavity. Fifteen specimens of each group were tested to failure with a single impact force applied at 90 degrees to the mid-point inciso-cervically on the labial surface. The peak force, peak energy, and first peak total energy required to fracture each specimen were recorded. The results showed no significant difference between the three groups, nor was a difference in the mode or site of fracture observed. The results suggested that there is no advantage from the point of view of fracture mechanics in 'restoring' intact root-treated teeth with either stainless steel or carbon fibre reinforced carbon rods. PMID:2098347

  4. [Resistance to fracture of direct restorations with cuspal coverage in endodontically treated upper bicuspids].

    PubMed

    Takahashi, C U; De Cara, A A; Contin, I

    2001-01-01

    Endodontically treated teeth are considered more susceptible to fracture because of the loss of tooth structure. The aim of this study was to evaluate the increase of resistance to fracture of upper bicuspids that underwent endodontic access and were restored with composite resin, with cuspal coverage. Forty extracted human maxillary premolars were divided in 4 groups: I--intact teeth; II--teeth with endodontic access and MOD preparation, restored with composite resin, without cuspal coverage; III--teeth with endodontic access, MOD preparation and occlusal reduction, restored with composite resin, with cuspal coverage; IV--teeth with endodontic access and MOD preparation, without any restoration. The test specimens were submitted to compression test up to their fracture. The test of Turkey and the ANOVA analysis were used to compare and test the results. The teeth from group III (with cuspal coverage) presented with significantly greater resistance to fracture, when compared with those from groups II (restored without cuspal coverage) and IV (not restored). The composite restoration with cuspal coverage can be considered an alternative for endodontically treated premolars. PMID:11705272

  5. A retrospective study of patients with mandibular fractures treated at a Swedish University Hospital 1999-2008

    PubMed Central

    Ramadhan, Anwar; Gavelin, Petter; Hirsch, Jan M.; Sand, Lars P.

    2014-01-01

    Background: Fracture of the mandible is one of the most common fractures of the maxillofacial skeleton. However, the etiology, gender, and age distribution vary between different regions and countries, and the purpose of this study was to evaluate the current trend of patients with mandibular fractures at the Department of Oral and Maxillofacial Surgery, in Uppsala, Sweden. Aim: The aim of this retrospective study was to analyze patients with mandibular fractures treated in the University Hospital of Uppsala (the county capital of Uppland) Sweden during a 10-year period (1999-2008). Materials and Methods: This study was designed as a retrospective study of patients admitted to the Department of Oral and Maxillofacial Surgery at Uppsala University Hospital, Sweden. The location of fractures was evaluated clinically by the surgeon and on the X-rays. We classified the data according to gender, age, etiology, day of the week, month of the year, fracture site, and method of treatment of the fractures. Results: Records were collected from patient charts from 266 patients. One hundred eighty-seven patients (70%) with mandibular fractures were of male gender, and 132 patients (50%) were aged 16-30 years. Interpersonal violence constituted the most common etiological factor for mandibular fractures (24%), followed by falls (23%). Forty-nine percentages of the patients were treated surgically, and 51% were treated conservatively. There was an increase of the annual incidence of fractures toward the end of the period, even though not statistically significant. Conclusions: Mandibular fractures occurred primarily among younger men between 16- and 30-year-old. Condyle fractures were the most common fracture site and 50% of the patients required surgery. Summer months and weekends were the most common time of mandibular fractures. PMID:25593868

  6. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    PubMed Central

    Prasad, G Thiruvengita; Kumar, T Suresh; Kumar, R Krishna; Murthy, Ganapathy K; Sundaram, Nandkumar

    2013-01-01

    Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women) who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years). All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP) and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and allows early knee

  7. Retained Sponge: A Rare Complication in Acetabular Osteosinthesis

    PubMed Central

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Moran-Blanco, Luz María; Vaquero-Martín, Javier

    2015-01-01

    Retained sponges after a surgical treatment of polytrauma may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a 35-year-old man transferred from another hospital, that sustained a open acetabular fracture. The fracture was reduced through a limited ilio-inguinal approach. After 4 days, he presented massive wound dehiscence of the surgical approach. An abdominal CT scan showed, lying adjacent to the outer aspect of the left iliac crest, a mass of 10 cm, identified as probable foreign body. The possibility of this rare complication should be in the differential diagnosis of any postoperative patient who presents with pain, infection, or palpable mass. PMID:26312116

  8. A 5-year study of the outcome of surgically treated depressed skull fractures.

    PubMed Central

    Al-Haddad, Syed A.; Kirollos, Ramez

    2002-01-01

    BACKGROUND: Many changes and improvement have taken place in the management of head injured patients in the last 20 years. There have been few recent studies analysing the overall outcomes including early complications of depressed skull fractures. The aim of our study was, therefore, to examine the factors influencing the surgical outcome of patients with depressed skull fractures. METHODS: We reviewed case notes of 73 consecutive surgically treated depressed skull fractures during the period from 1 January 1994 to 31 December 1998 admitted to the Walton Centre for Neurology and Neurosurgery, Liverpool. RESULTS: There was a male preponderance of 9:1. Alleged assault was the most common cause of depressed skull fractures followed by road traffic accidents. Postoperative infection rate was 8.2%. More than 80% of patients received prophylactic antibiotics. We failed to show any statistically significant association between the use of antibiotics and reduction of the rate of infection. However, prevalence of infection was significantly associated with brain contusion, low GCS score and dural tear (P < 0.05). Prevalence of early post-traumatic epilepsy was 12.3%. No patients received prophylactic anticonvulsants. There was no significant association between dural tear and prevalence of post-traumatic epilepsy. Mortality rate was 1.4%. CONCLUSIONS: Paediatric populations have better outcome; 7 out of 10 patients in this series progressed to full recovery. Use of prophylactic antibiotics did not reduce the infection rate. Presence of dural tear was not associated with an increase risk of post-traumatic epilepsy. PMID:12092875

  9. Lunate Osteochondral Fracture Treated by Excision: A Case Report and Literature Review

    PubMed Central

    Saberi, Sadegh; Arabzadeh, Aidin; Farhoud, Amir Reza

    2016-01-01

    Introduction Lunate fracture is a rare injury. Most reports are associated with other wrist injuries such as perilunate dislocation and distal radius fracture. Isolated lunate fracture has been reported even more rarely. The choice of treatment and outcomes are consequently undetermined. Case Presentation In this case report we will describe a lunate avulsion fracture as an isolated injury after a fall from nine meters treated operatively by excision of the comminuted avulsed fragment. After 33 months of follow-up radiographs showed no sign of degenerative joint disorder on simple X-ray, but slight Volar Intercalated Segment Instability (VISI) by a capitolunate angle of 26 degrees was noted. Clinically, the patient was pain free near full wrist and forearm range of motion and could perform his previous vocational and recreational tasks without any limitations. Conclusions Despite apparently good short and mid-term clinical outcome, slight volar intercalated segment instability after 33 months of follow-up revealed that lunotriquetral ligament function was probably lost, which led to static instability. This ligament injury may be missed primarily. Excision of the avulsed osteochondral fragment should be the last option of treatment and most attempts should be tried to fix and/or restore the normal anatomy of ligamentous structure.

  10. Tibial spine fractures: an analysis of outcome in surgically treated type III injuries.

    PubMed

    Mulhall, K J; Dowdall, J; Grannell, M; McCabe, J P

    1999-05-01

    We analysed the outcome of open reduction and internal fixation of type III tibial spine fractures, assessing treatment and determining a treatment protocol. A total of 10 patients presented over 3 years to our institution with a mean age of 15 years (range 10-21), a male-to-female ratio of 8:2. left to right 6:4 and anterior to posterior spine fracture 9:1. Only one patient had associated meniscal injury noted at arthroscopy (no treatment required). The mode of injury was road traffic accidents four, sports injuries three and falls three. The mean follow-up was 9 months. There were seven excellent results and three good results. Those patients with good results exhibited either minimal quadriceps weakness, extensor lag (< 10 degrees) or antero-posterior laxity. This reflects the experience of other authors in dealing with these injuries in younger patients. There is widespread agreement that types I and II should be treated by plaster cast alone and that is also the policy at our institution. We recommend a routine treatment protocol in type III injuries of (1) examination under anaesthesia, (2) arthroscopy (evaluating the fracture, cruciate integrity and other associated injuries), (3) open reduction and screw fixation and (4) vigorous physiotherapy/rehabilitation of all type III fractures, as we feel this provides the best possible outcome in these injuries. PMID:10476299

  11. Lateral Condyle Fracture of the Humerus in Children Treated with Bioabsorbable Materials

    PubMed Central

    Tercier, Stéphane; Bregou-Bourgeois, Aline; Zambelli, Pierre-Yves

    2013-01-01

    The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children. PMID:24228016

  12. Delirium is associated with poor rehabilitation outcome in elderly patients treated for femoral neck fractures.

    PubMed

    Olofsson, Birgitta; Lundström, Maria; Borssén, Bengt; Nyberg, Lars; Gustafson, Yngve

    2005-06-01

    The aim of this study was to describe risk factors for delirium and the impact of delirium on the rehabilitation outcome for patients operated for femoral neck fractures. Sixty-one patients, aged 70 years or older, consecutively admitted to the Department of Orthopaedic Surgery at Umeå University Hospital, Sweden for femoral neck fractures were assessed and interviewed during hospitalization and at follow up 4 months after surgery. Delirium occurred in 38 (62%) patients and those who developed delirium were more often demented and/or depressed. Patients with delirium were longer hospitalized and they were more dependent in their activity of daily living (ADL) on discharge and after 4 months. They had poorer psychological well-being and more medical complications than the nondelirious. A large proportion of the patients who developed delirium did not regain their previous walking ability and could not return to their prefracture living accommodation. Delirium after hip fracture surgery is very common especially among patients with dementia or depression. This study shows that delirium has a serious impact on the rehabilitation outcome from both short- and long-term perspectives. Because delirium can be prevented and treated, it is important to improve the care of elderly patients with hip fractures. PMID:15877637

  13. Cost implications of the physiotherapy management of complex tibial fractures treated with circular frames.

    PubMed

    Barron, E; Rambani, R; Bailey, H; Sharma, H K

    2013-11-01

    Seventy-three consecutive patients with complex tibial fractures treated with an Ilizarov frame or Taylor Spatial Frame received physiotherapy between April 2008 and April 2010. Data were collected prospectively, and physiotherapy input was recorded (in minutes) for the patients identified. This included treatment received as an inpatient as well as an outpatient. The data were categorized for proximal, middle and distal third tibial fractures for analysis. The average cost of physiotherapy for an inpatient with an Ilizarov frame is £121.82 per case, whereas that for an outpatient receiving treatment for trauma was calculated as £404.60. The combined average cost of physiotherapy to support treatment of a complex tibial fracture with a fine wire fixator is £546.27. Treatment involving circular frames is complex and expensive, and the high physiotherapy cost is not reflected in Healthcare Resource Group codes. This cost calculation will help service units, and NHS Trusts develop realistic costing plans to support treatment. Cost implications of the physiotherapy management of complex tibial fractures using the Ilizarov technique. PMID:23943063

  14. Importance of maintaining the basic stress pathway above the acetabular dome during acetabular reconstruction.

    PubMed

    Nie, Yong; Pei, Fuxing; Shen, Bin; Kang, Pengde; Li, Zongming

    2016-07-01

    The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in press-fit acetabular reconstruction of total hip arthroplasty. However, information on the basic stress pathway and its impact factors remains unclear. The objective of this study was to investigate the effects of the orientations and positions of the acetabular component on the basic stress pathway. The basic stress pathway above the acetabular dome was defined as two parts: 3D basic trabecular bone stress distribution and quantified basic cortical bone stress level, using two subject-specific finite element normal hip models. The effects were then analysed by generating 32 reconstructed acetabular cases with different cup abduction and anteversion angles within a range of 35-50° and 10-25°, respectively, and 12 cases with different hip centre heights within a range of 0-15 mm above the acetabular dome. The 3D trabecular stress distribution decreased remarkably in all cases, while the 80% of the basic cortical bone stress level was maintained in cases when the acetabular component was positioned at 10° or 15° anteversion and 40° or 45° abduction angles. The basic stress pathway above the acetabular dome was disturbed when the superior displacement of the hip centre exceeded 5 mm above the anatomical hip centre. Positioning the acetabular component correctly contributes to maintain the stress balance between the acetabular cup and the bone during acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants. PMID:26469561

  15. Radiological evaluation of acetabular erosion after antibiotic-impregnated polymethylmethacrylate spacer (Spacer-G).

    PubMed

    García-Oltra, Ester; Bori, Guillem; Tomas, Xavier; Gallart, Xavier; Garcia, Sebastian; Soriano, Alex

    2013-06-01

    Different types of hip spacers have been described (hand-made, custom-molded or prefabricated) for treatment of a chronic hip infection. A potential disadvantage of monoblock prefabricated spacer is that it may cause acetabular bone loss. This study assesses the radiological acetabular erosion using an antibiotic-impregnated pre-fabricated polymethylmethacrylate Spacer-G. We retrospectively reviewed the radiographs of thirty five patients who were managed with Spacer-G to treat chronic hip infection. No acetabular erosion were observed in thirty two patients with a mean time from the first to second stage and from the first to the last radiograph of 5.09 and 3.77 months respectively. In three patients the time between the radiographs was more than one year and the second stage was not performed; two developed a protrusion acetabuli whereas the other one a destruction of the acetabular roof. Using a Spacer-G in chronic hip infection treatment for less than one year is not associated with radiological acetabular erosion if the patient is maintained at partial weight bearing. PMID:23142448

  16. Ten-year follow-up of the non-porous Allofit cementless acetabular component.

    PubMed

    Zenz, P; Stiehl, J B; Knechtel, H; Titzer-Hochmaier, G; Schwagerl, W

    2009-11-01

    Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation. This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final follow-up at a mean of 10.1 years (8.9 to 11.9). The Harris Hip Score improved from a mean 53 points (23 to 73) pre-operatively to a mean of 96 points (78 to 100) at final review. The osseointegration of all acetabular components was radiologically evaluated with no evidence of loosening. The survival rate with revision of the component as the endpoint was 97.5% (95% confidence interval 94 to 100) after 11.9 years. Radiolucency was found in one DeLee-Charnley zone in four acetabular components. None of the implants required revision for aseptic loosening. Two patients were treated for infection, one requiring a two-stage revision of the implant. One femoral stem was revised for osteolysis due to the production of metal wear debris, but the acetabular shell did not require revision. This study demonstrates that a non-porous titanium acetabular component with adjunct surface fixation offers an alternative to standard porous-coated implants. PMID:19880887

  17. Effectiveness of MIS technique as a treatment modality for open intra-articular calcaneal fractures: A prospective evaluation with matched closed fractures treated by conventional technique.

    PubMed

    Dhillon, Mandeep Singh; Gahlot, Nitesh; Satyaprakash, Sambit; Kanojia, Rajendra Kumar

    2015-09-01

    Twenty-five displaced intra-articular calcaneal fractures in 21 patients, aged 15-55 years were included in this study. Sanders' type I fractures, severe crushing or partial amputation, were excluded from the study. Patients were divided into group 1 (open fractures treated by MIS), and group 2 (closed fractures treated by ORIF). Group 1 had 16 and group 2 had 9 cases. Seven of 25 fractures (28%) developed wound related issues postoperatively. One patient (11.1%) in group 2 had wound margin necrosis, while 6 patients (37.5%) in group 1 developed pin tract and/or wound infection. At 1-year follow-up, the mean MFS for group 1 was 79 and mean MFS for group 2 was 84.4 (66.67% were good). The AOFAS score for group 1 was 77.37 and for group 2 was 86.1. The Bohlers' angle was restored in 81.16% cases in group 1 and 88.8% in group 2, while Gissane angle was restored in 68.75% of group 1 cases and 77.79% of group 2 cases. This study shows that acceptable fracture reduction can be obtained and maintained by MIS technique and it can be used as the primary definitive treatment option in open calcaneal fractures. PMID:26209469

  18. Contemporary demographics and complications of patients treated for open ankle fractures.

    PubMed

    Ovaska, Mikko T; Madanat, Rami; Honkamaa, Maija; Mäkinen, Tatu J

    2015-08-01

    Open ankle fractures are rare injuries with a high likelihood of wound complications and subsequent infections. There is limited information about the complications and outcomes of these injuries in different age groups. The aim of this study was to assess the contemporary demographics and complications related to this injury. We performed a chart review of all the 3030 patients treated for ankle fractures at a Level 1 trauma centre from 2006 to 2011. 137 (4.5%) patients had an open ankle fracture. The demographic data, injury mechanism, comorbidities, and fracture type were collected. Treatment, complications, length of stay and number of outpatient visits were also recorded. The mean age of the patients was 60 years and 56% were women. Most fractures were Weber type B with a medial sided wound (93%). Only 20% of the fractures were the result of high-energy trauma, and 31% were Gustilo grade III injuries. Immediate internal fixation was performed in 82% of patients, and the wound was primarily closed in most cases (80%). The incidence of postoperative wound necrosis and deep infection was 18% and 17%, respectively. There were more deep infections if pulsatile lavage was used during the wound debridement (p=0.029). About 14 (10%) patients required a flap reconstruction to cover the soft-tissue defect. Every other patient (54%) had a complication, and 21 patients (15%) suffered a long-term disability related to the injury. The number complications did not differ for nighttime and daytime operations (p=0.083). High-energy injuries were more common in younger patients (p<0.001) and these patients also had more lateral sided open wounds than older patients (p=0.002). Interestingly, younger patients also had significantly more complications (p=0.024), suffered more often from chronic pain (p=0.003), and required more flap reconstructions (p=0.026), reoperations (p=0.026), and outpatient clinic visits (p=0.006). Open ankle fractures have a high complication rate and

  19. Porous-coated acetabular components with screw fixation. Five to ten-year results.

    PubMed

    Latimer, H A; Lachiewicz, P F

    1996-07-01

    The results of 136 consecutive primary total hip arthroplasties performed by one surgeon with the Harris-Galante-I porous-coated acetabular component were reviewed at a mean of seven years (range, five to ten years). In all hips, the outer diameter of the acetabular component was the same as the diameter of the final reamer used in the preparation of the acetabulum. However, this reamer was used only briefly at the rim of the acetabulum, and therefore the components had so-called press-fit stability. A mean of four screws (range, three to six screws) were used for additional fixation of the component. The clinical evaluation was performed with use of the Harris hip score. Standardized anteroposterior radiographs of the pelvis were assessed for migration of the component, radiolucent and radiodense lines, linear wear of the polyethylene, and osteolysis. No acetabular component had been revised for loosening and none were radiographically loose at the time of the most recent follow-up evaluation. There were no complications related to the use of the screws, and no screw had bent or broken. A non-progressive radiolucent line was seen in one acetabular zone in thirty-four hips (25 per cent) and in two acetabular zones in six hips (4 per cent). No hip had a radiolucent line in all three acetabular zones. The mean rate of linear wear of the polyethylene was 0.1 millimeter per year. There was no dissociation of the acetabular liner from the metal shell. Two hips (1 per cent) had asymptomatic osteolysis in the ischium and adjacent to the rim of the acetabular component; this was treated with grafting at the site of the lesion and exchange of the femoral head and the worn polyethylene liner. Five femoral components inserted without cement and one inserted with cement were revised because of loosening. The data suggest that, at a mean of seven years, fixation of this porous-coated component was uniformly excellent. The low prevalence of radiolucent lines and the absence of

  20. Stent strut fracture-induced restenosis in a bifurcation lesion treated with the crush stenting technique.

    PubMed

    Surmely, Jean-Francois; Kinoshita, Yoshihisa; Dash, Debabrata; Matsubara, Tetsuo; Terashima, Mitsuyasu; Ehara, Mariko; Ito, Tatsuya; Nasu, Kenya; Takeda, Yoshihiro; Tanaka, Nobuyoshi; Suzuki, Takahiko; Katoh, Osamu

    2006-07-01

    Percutaneous treatment of a bifurcation lesion still shows a significant complication rate, mainly because of restenosis at the ostial site of the side branch vessel. Different techniques, such as V-stenting, culottes-stenting or crush stenting, allow full ostial coverage and may therefore achieve uniform drug distribution within the lesion. The crush technique results in a strong mechanical constraint on the side branch stent. A case of stent strut fracture-induced restenosis in a bifurcation lesion treated with the crush stenting technique is described. PMID:16799252

  1. Transosseous Acetabular Labral Repair as an Alternative to Anchors

    PubMed Central

    Pérez-Carro, Luis; Cabello, Andres Gonzalez; Rakha, Mohamed Ibrahim; Patnaik, Sarthak; Centeno, Elias; Miranda, Victor; Fernández, Ana Alfonso

    2015-01-01

    Labral tears are the most common pathology in patients undergoing hip arthroscopy and the most common cause of mechanical hip symptoms. Labral repair techniques have been described in the literature using suture anchors placed as close as possible to the acetabular rim without penetrating the articular surface. Optimal surgical technique for labral repair is very important, and an inappropriate entry point and guide angulation may lead to intra-articular penetration of the anchor, chondral damage, anchor loosening, or inadequate fixation. A shallow dysplastic hip, the drilling trajectory, the narrow width of the acetabular rim, or some specific anatomic variations may generate difficulty during anchor placement. Suture anchors themselves have been associated with several significant complications, including rim fracture, osteolysis, enlargement of drill holes, and infection. The treatment of labral lesions with transosseous suture is an alternative to anchor use, eliminating the need for anchors and avoiding anchor-associated complications. This technique offers versatility to surgeons and is more cost-effective for patients and health services. We aim to describe the indications and technique for transosseous labral repair without anchors. PMID:26697295

  2. A Novel Thresholding Based Algorithm for Detection of Vertical Root Fracture in Nonendodontically Treated Premolar Teeth

    PubMed Central

    Johari, Masume; Esmaeili, Farzad; Andalib, Alireza; Garjani, Shabnam; Saberkari, Hamidreza

    2016-01-01

    In this paper, an efficient algorithm is proposed for detection of vertical root fractures (VRFs) in periapical (PA), and cone-beam computed tomography (CBCT) radiographs of nonendodontically treated premolar teeth. PA and CBCT images are divided into some sub-categories based on the fracture space between the two fragments as small, medium, and large for PAs and large for CBCTs. These graphics are first denoised using the combination of block matching 3-D filtering, and principle component analysis model. Then, we proposed an adaptive thresholding algorithm based on the modified Wellner model to segment the fracture and canal. Finally, VRFs are identified with a high accuracy through applying continuous wavelet transform on the segmented radiographs and choosing the most optimal value for sub-images based on the lowest interclass variance. Performance of the proposed algorithm is evaluated utilizing the different tested criteria. Results illustrate that the range of specificity deviations for PA and CBCT radiographs are 99.69 ± 0.22 and 99.02 ± 0.77, respectively. Furthermore, the sensitivity changes from 61.90 to 77.39 in the case of PA and from 79.54 to 100 in the case of CBCT. Based on our statistical evaluation, the CBCT imaging has the better performance in comparison with PA ones, so this technique could be a useful tool for clinical applications in determining the VRFs. PMID:27186535

  3. A Novel Thresholding Based Algorithm for Detection of Vertical Root Fracture in Nonendodontically Treated Premolar Teeth.

    PubMed

    Johari, Masume; Esmaeili, Farzad; Andalib, Alireza; Garjani, Shabnam; Saberkari, Hamidreza

    2016-01-01

    In this paper, an efficient algorithm is proposed for detection of vertical root fractures (VRFs) in periapical (PA), and cone-beam computed tomography (CBCT) radiographs of nonendodontically treated premolar teeth. PA and CBCT images are divided into some sub-categories based on the fracture space between the two fragments as small, medium, and large for PAs and large for CBCTs. These graphics are first denoised using the combination of block matching 3-D filtering, and principle component analysis model. Then, we proposed an adaptive thresholding algorithm based on the modified Wellner model to segment the fracture and canal. Finally, VRFs are identified with a high accuracy through applying continuous wavelet transform on the segmented radiographs and choosing the most optimal value for sub-images based on the lowest interclass variance. Performance of the proposed algorithm is evaluated utilizing the different tested criteria. Results illustrate that the range of specificity deviations for PA and CBCT radiographs are 99.69 ± 0.22 and 99.02 ± 0.77, respectively. Furthermore, the sensitivity changes from 61.90 to 77.39 in the case of PA and from 79.54 to 100 in the case of CBCT. Based on our statistical evaluation, the CBCT imaging has the better performance in comparison with PA ones, so this technique could be a useful tool for clinical applications in determining the VRFs. PMID:27186535

  4. Influence of fiber posts on the fracture resistance of endodontically treated premolars with different dental defects

    PubMed Central

    Hou, Qian-Qian; Gao, Yi-Ming; Sun, Lei

    2013-01-01

    This study aimed to evaluate the influence of quartz fiber post placement on the fracture resistance of endodontically treated premolars with different dental defects under dynamic loading. Fifty extracted single-rooted mandibular premolars were randomized into five groups. Each group was prepared according to numbers of residual walls ranged from 0 to 4. Then each group was divided into two subgroups with one restored with quartz fiber posts and the other without posts. In no-post groups, gutta percha point 2 mm below cemento-enamel junction was removed. Composite resin was adapted to the well and used to shape the core directly. Each tooth was restored with a complete metal crown. Dynamic loading was carried out in a masticatory simulator with a nominal load of 50 N at 2 Hz for 300 000 loading cycles. Then a quasi-statically load was applied in a universal testing machine 30° to the long axis with a crosshead speed of 1 mm⋅min−1 until fracture. Data were analyzed with one-way analysis of variance and pairwise comparison (P<0.05). No specimens failed during dynamic loading. The fracture resistance enhanced with the increase of numbers of coronal walls and the differences were significant (P<0.05). Placement of fiber posts had a significant effect when fewer than two walls remained (P<0.05), but it had no significant influence in groups with two, three or four walls (P>0.05). Fiber post did not change failure mode, and the fracture pattern was mainly favorable. More dentin walls need to be retained in clinic. When no less than two walls remained, a fiber post is not always necessary. PMID:23907677

  5. The acetabular component: an elliptical monoblock alternative.

    PubMed

    Sculco, Thomas P

    2002-06-01

    The major failure mode of cemented or noncemented acetabular fixation is osteolysis produced by biologic reaction to polyethylene and metallic debris. A monoblock acetabular noncemented component offers advantages in reducing the failure mechanism of acetabular cups. First, there is no extra-articular back surface polyethylene wear. Second, locking rings that may generate metallic debris are eliminated. Third, screw-holes, which decrease the surface area for ingrowth, are not needed, and pelvic entrance points for wear debris are eliminated. Fourth, an elliptical configuration allows better coaptation of the shell to the dome of the acetabulum. I have implanted >2,400 elliptical monoblock acetabular cups with a short-term follow-up of 6.5 years, with >4 years of follow-up in 840 hips. There have been no mechanical failures requiring revision. Four patients have been revised for recurrent hip instability, and one has been revised for infection. The need to convert to an acetabular component with screw fixation because of poor press-fit is <1%. PMID:12068420

  6. Comparison of fracture resistance and failure pattern of endodontically treated premolars with different esthetic onlay systems: An in vitro study

    PubMed Central

    Mynampati, Praffulla; Babu, Mandava Ramesh; Saraswathi, Devabhaktuni Disha; Kumar, Janga Ravi; Gudugunta, Leneena; Gaddam, Divya

    2015-01-01

    Aim: To compare the fracture resistance and modes of failures of three different aesthetic MOD onlays on endodontically treated premolars. Materials and Methods: Forty sound maxillary premolars were selected of which 10 untreated teeth were taken as control (Group I). The other thirty premolars were subjected to standardized MOD onlay preparations and root canal treatments and divided into 3 equal groups. Onlays were prepared in Group II- Indirect composite, Group III- Lithium Disilicate ceramic and Group IV- Full Zirconia. All onlays were cemented using Multilink Automix. All the 40 samples were subjected to fracture resistance testing on Universal testing machine. Also fractured specimens were observed under stereo-microscope for modes of failure. Results: Group IV presented the highest fracture resistance. Groups II and III presented no significant difference in fracture resistance from each other (P > 0.05). Group II and Group III showed significantly lower fracture resistance values than Group I. Coming to modes of failure, only Group IV had showed no cracks in any of the restorations. Conclusion: Full Zirconia MOD onlays increased the fracture resistance of endodontically treated premolars to a significantly higher level than the sound teeth. PMID:25829694

  7. Effects of a training program after surgically treated ankle fracture: a prospective randomised controlled trial

    PubMed Central

    Nilsson, Gertrud M; Jonsson, Kjell; Ekdahl, Charlotte S; Eneroth, Magnus

    2009-01-01

    Background Despite conflicting results after surgically treated ankle fractures few studies have evaluated the effects of different types of training programs performed after plaster removal. The aim of this study was to evaluate the effects of a 12-week standardised but individually suited training program (training group) versus usual care (control group) after plaster removal in adults with surgically treated ankle fractures. Methods In total, 110 men and women, 18-64 years of age, with surgically treated ankle fracture were included and randomised to either a 12-week training program or to a control group. Six and twelve months after the injury the subjects were examined by the same physiotherapist who was blinded to the treatment group. The main outcome measure was the Olerud-Molander Ankle Score (OMAS) which rates symptoms and subjectively scored function. Secondary outcome measures were: quality of life (SF-36), timed walking tests, ankle mobility tests, muscle strength tests and radiological status. Results 52 patients were randomised to the training group and 58 to the control group. Five patients dropped out before the six-month follow-up resulting in 50 patients in the training group and 55 in the control group. Nine patients dropped out between the six- and twelve-month follow-up resulting in 48 patients in both groups. When analysing the results in a mixed model analysis on repeated measures including interaction between age-group and treatment effect the training group demonstrated significantly improved results compared to the control group in subjects younger than 40 years of age regarding OMAS (p = 0.028), muscle strength in the plantar flexors (p = 0.029) and dorsiflexors (p = 0.030). Conclusion The results of this study suggest that when adjusting for interaction between age-group and treatment effect the training model employed in this study was superior to usual care in patients under the age of 40. However, as only three out of nine outcome

  8. Coralline hydroxyapatite in complex acetabular reconstruction.

    PubMed

    Wasielewski, Ray C; Sheridan, Kate C; Lubbers, Melissa A

    2008-04-01

    This retrospective study examined whether a coralline hydroxyapatite bone graft substitute adequately repaired bone defects during complex acetabular reconstructions. Seventeen patients who underwent acetabular revision using Pro Osteon 500 were assessed to determine whether any cups required re-revision, whether bone had incorporated into the coralline hydroxyapatite grafts, and whether the coralline hydroxyapatite grafts resorbed with time. At latest follow-up, no cups required re-revision, but 1 had failed. Radiographic evidence of bone incorporation was observed in every coralline hydroxyapatite graft. Graft resorption was not observed. PMID:19292282

  9. Subchondral Insufficiency Fracture of the Femoral Head treated with Core Decompression and Bone Void Filler Support

    PubMed Central

    Patel, Hiren; Kamath, Atul F.

    2016-01-01

    Subchondral insufficiency fracture of the femoral head (SIFFH) is characterized by acute onset hip pain without overt trauma. It appears as a low intensity band with bone marrow edema on T1-weighted MRI. The most common course of treatment is protected weight bearing for a period of several weeks. Total hip arthroplasty (THA) has been commonly used if the patient does not respond to the initial protected weight bearing treatment. We present a case of a 48-year-old male with SIFFH who was treated with core hip decompression and bone void filler as a hip-preserving alternative to THA. The patient has an excellent clinical and radiographic result at final follow up. Core hip decompression with bone void filler is a less invasive alternative to THA, and may be a preferred initial treatment strategy for SIFFH in the young and active patient who has failed conservative measures. PMID:27517074

  10. Postoperative bedrest improves the alignment of thoracolumbar burst fractures treated with the AO spinal fixator

    PubMed Central

    Dang, Yen; Yen, David; Hopman, Wilma M.

    2009-01-01

    Background A loss of reduction due to inadequate support of the anterior column when using short-segment instrumentation to treat burst fracture and novel methods for support of the anterior column through a posterior approach to augment posterior instrumentation have been reported in the literature. We hypothesized that if anterior column support is an important adjunct to posterior short-segment instrumentation, then avoidance of axial load until sufficient anterior column healing occurs, allowing load-sharing with the implant, would improve spinal alignment at follow-up. Methods We conducted a retrospective cohort study in which consecutive patients who had instrumentation and fusion with the AO spinal fixator were immediately ambulated after surgery or had 4 weeks of bedrest. We measured kyphosis and wedge angles preoperatively, immediately postoperatively and at the time of final follow-up. We used radiologic measures to assess instrumentation and bone failure. Results We found significant differences in the mean loss of wedge and kyphosis angle correction between patients immediately ambulated and those who had 4 weeks of bedrest (0.71º v. − 4.73º for wedge and 1.81º v. − 6.55º for kyphosis, respectively). There was significant correlation between instrumentation and bone failure in both the immediate ambulation and bedrest groups. Conclusion Bedrest improves the maintenance of intraoperative sagittal alignment correction, which is in agreement with the theory that inadequate support of the anterior spinal column is the mechanism for loss of reduction when using short-segment instrumentation to treat burst fractures. Therefore, addressing the anterior column directly through anterior surgery or by employing novel techniques in posterior surgery is recommended if one of the goals of treatment is to maintain the sagittal correction achieved at the time of surgery. Trying to achieve this goal by addressing posterior implant design or bone quality alone

  11. Fracture resistance of endodontically treated teeth restored with indirect composite inlay and onlay restorations – An in vitro study

    PubMed Central

    Alshiddi, Ibraheem F.; Aljinbaz, Amjad

    2015-01-01

    Objective The purpose of this in vitro study was to evaluate and compare the fracture resistance and fracture mode of extensive indirect inlay and onlay composite resin restorations performed for endodontically treated premolars. Materials and methods A total of 55 extracted maxillary premolars were randomly divided into four groups. The first group (n = 15) remained untreated to serve as a positive control; the second group (n = 15) was endodontically treated with inlay cavities prepared and restored with indirect composite inlay restorations; the third group (n = 15) was also endodontically treated with onlay cavities prepared and restored with indirect composite onlay restorations; and the fourth group (n = 10) was endodontically treated with mesio-occlusodistal (MOD) cavities prepared and left unrestored to serve as negative controls. Dual cure indirect composite resin was used to fabricate the inlay and onlay restorations performed for the second and third groups, respectively. All teeth were subjected to compressive axial loading test using a metal ball (6 mm in diameter) in a universal testing machine (Instron 1195) with a cross-head speed of 0.5 mm/min until a fracture occurred. Statistical analysis of fracture resistance and fracture mode were performed with analysis of variance (ANOVA) (α = 0.05) and Kruskal–Wallis (α = 0.05) tests, respectively. Results For the four treatment groups, the mean fracture resistance values were 1326.9 N, 1500.1 N, 1006.1 N, and 702.7 N, respectively. Statistical analyses showed no significant differences between the mean fracture resistance of the intact tooth group and the inlay restoration group (p > 0.05), while significant differences were observed between the mean fracture resistance of all the other groups (p < 0.05). The Kruskal–Wallis test showed statistically significant differences between the fracture modes of the four groups. Conclusion Within the limitations of this study

  12. Uncemented acetabular components with femoral head autograft for acetabular reconstruction in developmental dysplasia of the hip: a concise follow-up report at a mean of twenty years.

    PubMed

    Abdel, Matthew P; Stryker, Louis S; Trousdale, Robert T; Berry, Daniel J; Cabanela, Miguel E

    2014-11-19

    We previously reported the five to twelve-year results of total hip arthroplasty with an uncemented acetabular component and an autogenous femoral head graft in forty-four consecutive hips with developmental dysplasia. The goal of the present study was to report the implant survival rate, status of bone grafts, and clinical outcomes in thirty-five of these hips (in twenty-nine patients) followed for a mean of 21.3 years. Functional, radiographic, and survivorship results were examined. Radiographic analysis revealed an average cup inclination angle of 43° and a mean arc of cup coverage by the graft of 30°. The twenty-year survivorship free from acetabular revision was 66% (twelve acetabular revisions; eight since our previous report). Of the twelve revisions, nine were for liner wear and/or osteolysis, one was for a liner fracture, one was for aseptic loosening, and one was for instability. All bone grafts healed to the pelvis. The graft facilitated revision cup placement as no additional structural grafts or metal augments were required. We concluded that an uncemented porous-coated socket used in conjunction with a bulk femoral head autograft provides good long-term fixation and restores bone stock. PMID:25410505

  13. Acromial approach for treating glenoid fractures: A report of two cases and a literature review

    PubMed Central

    AO, RONGGUANG; YU, BAOQING; SHI, JIFEI; LI, ZEXIANG; ZHU, YALONG

    2015-01-01

    Surgery is usually recommended for displaced glenoid fractures, with open reduction and internal fixation as the standard operative treatment. Three approaches have been recommended in the reduction of glenoid fractures: Anterior, posterior and combined; however, a traditional approach may be difficult due to a high position or a comminuted Ideberg type III fracture. The combined approach results in a longer incision and more soft tissue injury when associated with an acromial fracture. The present study describes two complicated glenoid fractures: One case was a comminuted Ideberg type III fracture associated with an Ogawa type II acromial fracture; the second case was an Ideberg type IV fracture with associated superior shoulder suspensory complex injuries. In these cases, the acromial approach was modified to achieve satisfactory exposure and fixation of the complicated fracture. After a 1-year follow-up, the patients had a satisfactory outcome. PMID:26640532

  14. Fractures

    PubMed Central

    Hall, Michael C.

    1963-01-01

    Recent studies on the epidemiology and repair of fractures are reviewed. The type and severity of the fracture bears a relation to the age, sex and occupation of the patient. Bone tissue after fracture shows a process of inflammation and repair common to all members of the connective tissue family, but it repairs with specific tissue. Cartilage forms when the oxygen supply is outgrown. After a fracture, the vascular bed enlarges. The major blood supply to healing tissue is from medullary vessels and destruction of them will cause necrosis of the inner two-thirds of the cortex. Callus rapidly mineralizes, but full mineralization is achieved slowly; increased mineral metabolism lasts several years after fracture. PMID:13952119

  15. The effect of amount of lost tooth structure and restorative technique on fracture resistance of endodontically treated premolars

    PubMed Central

    Bassir, Mahshid Mohammadi; Labibzadeh, Akram; Mollaverdi, Fatemeh

    2013-01-01

    Aim: Endodontic treatment generally reduces the fracture resistance of teeth. The purpose of this study was to evaluate the fracture resistance and the mode of fracture of endodontically treated human premolars with different amounts of remaining tooth structure. Materials and Methods: Seventy non-carious human premolars were randomly assigned into 7 groups. Group 1 (ST) did not receive any preparation. The teeth in groups 2-7 received root canal treatment and different preparations. Group 2 (MO-NF): Mesio-occlusal preparation without filling; Group 3 (MOD-NF): Mesio-occluso-distal preparation without filling; Group 4 (MO-F): Mesio-occlusal preparation with direct composite restoration (Z250); Group 5 (MOD-F): Mesio-occluso-distal preparation with direct composite restoration (Z250); Group 6 (CC-D): Mesio-occluso-distal preparation with cusp reduction and direct composite restoration (Z250); Group 7 (CC-InD): Mesio-occluso-distal preparation with cusp reduction and indirect composite restoration (Gradia GC). The fracture resistance (N) was assessed under compressive load in a universal testing machine (Zwick) perpendicular to the occlusal surface at a cross-head speed of 1 mm/min, and the mode of fracture was assessed under stereomicroscope. Statistical analysis: Data was analyzed by Kruskal – Wallis and Mann – Whitney tests and the mode of fracture was analyzed by Chi-square test (P < 0.05). Results: Statistical analysis showed that MO and MOD cavity preparations significantly reduced the fracture resistance of sound teeth. Direct composite restorations can improve the fracture resistance, and Groups 7 and 6 presented the highest fracture resistance values. Conclusions: Teeth with adhesive restorations showed significantly higher fracture resistance values as compared with the non-restored ones. PMID:24082569

  16. Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life

    PubMed Central

    Tsitsilonis, Serafim; Machó, David; Manegold, Sebastian; Krapohl, Björn Dirk; Wichlas, Florian

    2016-01-01

    Introduction/background: The operative treatment of distal radius fractures has significantly increased after the introduction of locking plates. The aim of the present study was the evaluation of health-related quality of life, functional and radiological outcome of patients with distal radius fractures treated with the locking compression plate (LCP). Materials and methods: In the present study 128 patients (130 fractures) that were operatively treated with the LCP (2.4 mm/3.5 mm, Synthes®) were retrospectively evaluated. Mean follow-up was 22.7 months (SD 10.6). The fractures were radiographically evaluated (radial inclination, palmar tilt, ulnar variance) pre-, postoperatively and at the last follow-up visit. Range of motion (ROM) was documented. Grip strength was assessed with the use of a JAMAR dynamometer. The score for disabilities of the arm, shoulder and hand (DASH) and the Gartland-Werley score (GWS) were evaluated. Health-associated quality of life was assessed with use of SF-36 Health Survey. Results: Postoperative reduction was excellent; at the last follow-up visit only minimal reduction loss was observed. Except for pronation, a statistically significant decrease of ROM was present; in most cases that was not disturbing for the patients. The injured side achieved 83.9% of grip strength of the intact side. Mean DASH was 18.9 and mean GWS was 3.5. Health-associated quality of life was generally not compromised. However, limitations in ulnar abduction correlated with inferior quality of life. Fracture severity correlated with inferior quality of life, despite the absence of correlation with the functional and radiological outcome. Complication rate was low. Conclusions: Fracture severity seems to affect ulnar abduction and therefore patient quality of life, despite almost anatomical reduction; the objective and subjective scores were in most cases excellent. Modern everyday activities, such as keyboard typing, could be associated with the present

  17. Massive acetabular bone loss: Limits of trabecular metal cages

    PubMed Central

    Villanueva-Martínez, Manuel; Ríos-Luna, Antonio; Diaz-Mauriño, Juán

    2011-01-01

    Massive acetabular bone loss (more than 50% of the acetabular area) can result in insufficient native bone for stable fixation and long-term bone ingrowth of conventional porous cups. The development of trabecular metal cages with osteoconductive properties may allow a more biological and versatile approach that will help restore bone loss, thus reducing the frequency of implant failure in the short-to-medium term. We report a case of massive bone loss affecting the dome of the acetabulum and the ilium, which was treated with a trabecular metal cage and particulate allograft. Although the trabecular metal components had no intrinsic stability, they did enhance osseointegration and incorporation of a non-impacted particulate graft, thus preventing failure of the reconstruction. The minimum 50% contact area between the native bone and the cup required for osseointegration with the use of porous cups may not hold for new trabecular metal cups, thus reducing the need for antiprotrusio cages. The osteoconductive properties of trabecular metal enhanced allograft incorportation and iliac bone rebuilding without the need to fill the defect with multiple wedges nor protect the reconstruction with an antiprotrusio cage. PMID:21221229

  18. Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years

    PubMed Central

    2012-01-01

    Background and purpose There have been few reports documenting the wear and oxidation performance of the polyethylene bearing surface of HGPI and HGPII THA devices. We evaluated retrieved HGPI and HGPII acetabular liners that had been in situ for more than 10 years and determined whether there was a relationship between clinical and radiographic factors, surface damage, wear, and oxidation. Materials and methods 129 HGPI and II acetabular liners with implantation times of > 10 years were retrieved at 4 institutions between 1997 and 2010. The liners were made from a single resin and were gamma radiation-sterilized in air. Surface damage, linear wear, and oxidation index (OI) were assessed. Differences in clinical and radiographic factors, surface damage, linear wear, and OI for the 2 designs were statistically evaluated separately and together. Results Articular surface damage and backside damage was similar in the 2 designs. The linear penetration rate was 0.14 (SD 0.07) mm/year for the HGPI liners and 0.12 (SD 0.08) mm/year for the HGPII liners. For both cohorts, the rim had a higher OI than the articular surface. 74% of the liners had subsurface cracking and 24% had a complete fracture through the acetabular rim. Interpretation Despite modification of the HGP locking mechanism in the HGPII design, dissociation of the liner from the acetabular shell can still occur if fracture of the rim of the liner develops due to oxidative degradation. PMID:22880709

  19. The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases.

    PubMed

    Schmalzried, T P; Wessinger, S J; Hill, G E; Harris, W H

    1994-06-01

    One hundred twenty-two primary total hip arthroplasties were followed for an average of 56 months (range, 48-66 months) in which the Harris-Galante (Zimmer, Warsaw, IN) porous ingrowth acetabular component had been press-fit into the innominate bone without screw fixation. There were no acetabular fractures. No socket was revised for loosening and none were radiographically loose. There was no evidence of disruption of the titanium porous mesh. There was no acetabular osteolysis. Compared to the authors' series of primary hip reconstructions using this same prosthesis inserted with line-to-line reaming and screw fixation, the data indicate that the tight peripheral fit associated with the press-fit technique is effective in reducing both the incidence and extent of bone-implant radiolucencies. However, the increased incidence of radiolucencies near the apex of the acetabulum also suggest that initial contact of the porous surface with live acetabular bone at this location is desirable in order to obtain and maintain an optimal bone-implant interface. Additional studies are necessary to further establish the relationship between the initial fit and long-term fixation of cementless acetabular components. Based on the data and other considerations for eliminating both vascular risk and the potential for fretting wear between the screws and shell, the authors recommend press-fitting without screw fixation for this acetabular component in primary cases when anatomy and bone stock permit. Full seating of the component is recommended in order to obtain dome contact. PMID:8077971

  20. Relationship between developmental dislocation of the hip in infant and acetabular dysplasia at skeletal maturity.

    PubMed

    Okano, Kunihiko; Yamaguchi, Kazumasa; Ninomiya, Yoshikazu; Matsubayashi, Shohei; Aoyagi, Kiyoshi; Osaki, Makoto; Enomoto, Hiroshi; Takahashi, Katsuro

    2015-01-01

    Previous reports demonstrated 8-60% patients treated for developmental dislocation of hip (DDH) in infancy have residual acetabular dysplasia (AD) at skeletal maturity. AD patients reportedly exhibit abnormal morphology of the pelvis, high rates of comorbid spinal congenital anomalies and high bone mineral density. These physical findings suggest that AD patients have genetic background. We examined the percentage of AD patients with hip pain at skeletal maturity having a history of DDH in infancy and the correlation between the severity of AD at skeletal maturity and history of DDH treatment to investigate the relationship between AD and DDH.A total of 245 patients were radiographically examined for any history of DDH treatment in infancy. The study included 226 women and 19 men with a mean age at examination of 40.7 years (range 17-59 years).Eighty-eight patients (36%) had a history of DDH treatment (DDH group) and the remaining 157 patients (64%) had no history of DDH treatment (non-DDH group). The average age was lower and acetabular angle was larger in the DDH group. There was a significant increasing trend of the percentage of DDH patients associated with the severity of AD classified with CE, acetabular angle, and acetabular roof angle.Our data suggest that there are several AD patients without a history of DDH in Japan, and AD in patients without a history of DDH has different characteristics from AD in patients with a history of DDH. PMID:25569642

  1. The role of cages in the management of severe acetabular bone defects at revision arthroplasty.

    PubMed

    Mäkinen, T J; Fichman, S G; Watts, E; Kuzyk, P R T; Safir, O A; Gross, A E

    2016-01-01

    An uncemented hemispherical acetabular component is the mainstay of acetabular revision and gives excellent long-term results. Occasionally, the degree of acetabular bone loss means that a hemispherical component will be unstable when sited in the correct anatomical location or there is minimal bleeding host bone left for biological fixation. On these occasions an alternative method of reconstruction has to be used. A major column structural allograft has been shown to restore the deficient bone stock to some degree, but it needs to be off-loaded with a reconstruction cage to prevent collapse of the graft. The use of porous metal augments is a promising method of overcoming some of the problems associated with structural allograft. If the defect is large, the augment needs to be protected by a cage to allow ingrowth to occur. Cup-cage reconstruction is an effective method of treating chronic pelvic discontinuity and large contained or uncontained bone defects. This paper presents the indications, surgical techniques and outcomes of various methods which use acetabular reconstruction cages for revision total hip arthroplasty. PMID:26733646

  2. Irreducible Atlanto-Axial Dislocation in Neglected Odontoid Fracture Treated with Single Stage Anterior Release and Posterior Instrumented Fusion

    PubMed Central

    Rathod, Ashok Keshav; Chaudhary, Kshitij Subhash

    2016-01-01

    It is a well-know fact that type 2 odontoid fractures frequently go into nonunion. If left untreated, patients may develop irreducible atlantoaxial dislocation (AAD). We describe the surgical management of two patients with neglected odontoid fractures and irreducible AAD treated with single stage anterior release followed by posterior instrumented fusion. Both patients presented with history of neglected trauma and progressive myelopathy. Traction under anesthesia failed to achieve reduction of AAD. Anterior release was done by trans-oral approach in one patient and retrophayngeal approach in the other. Posterior fixation was performed with transarticular screws in both the patients. Both patients had full neurological recovery and demonstrated fusion at follow-up. Anterior release followed by posterior instrumented correction may be an effective alternative to the traditional means of treating irreducible dislocations associated with neglected odontoid fractures. PMID:27114778

  3. Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns

    PubMed Central

    Alkumru, Hasan Necdet; Akalin, Buket

    2016-01-01

    PURPOSE The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND METHODS Two glass fiber reinforced post systems in two different sizes and polyethylene fiber ribbon in two different thicknesses (n=10) were used. The specimens, restored with all-ceramic crowns, were subjected to a compressive load (in N) delivered at a 130-degree angle to the long axis until a fracture could be noted. The results were analyzed statistically with a One-Way ANOVA test (P<.05). RESULTS Statistically significant differences were observed between the mean fracture resistance values of Postec, Snowlight, and Kerr Connect thin specimens (P<.0095). The Postec results (395.70 N) were found to be significantly higher than the others. No statistical difference was observed among the thick specimens (P<.2657). The mean fracture resistance values of the Snowlight thick samples were found to be higher than those of the Snowlight thin samples. The specimens were always fractured around the cemento-enamel junction at the palatinal side. No post fracture was observed for the thin Snowlight and Kerr Connect specimens or for the thick Postec and Kerr Connect specimens. Among the common failure types of the specimens, the worst was observed to be the root fracture failure. The highest post dislodgement failure result (80%) was obtained from the thin Kerr Connect specimen. CONCLUSION In terms of optimizing fracture resistance, the fiber post size selection should be done according to the forces applied to the restored teeth. PMID:27141261

  4. Fractures

    MedlinePlus

    ... commonly happen because of car accidents, falls, or sports injuries. Other causes are low bone density and osteoporosis, which cause weakening of the bones. Overuse can cause stress fractures, which are very small cracks in the ...

  5. Fractures

    MedlinePlus

    A fracture is a break, usually in a bone. If the broken bone punctures the skin, it is called an open ... falls, or sports injuries. Other causes are low bone density and osteoporosis, which cause weakening of the ...

  6. The ability of cone-beam computerized tomography to detect vertical root fractures in endodontically treated and nonendodontically treated teeth: a report of 3 cases.

    PubMed

    Zou, Xiaoying; Liu, Denggao; Yue, Lin; Wu, Minkai

    2011-06-01

    A definitive diagnosis of vertical root fracture (VRFs) is often a challenging task for clinicians. Two-dimensional periapical radiographs (PRs) may be not helpful in such a diagnosis when the x-ray beam is not parallel to the plane of the fracture line. This report presents a set of 3 cases in which 1 endodontically treated and 2 nonendodontically treated mandibular molars were diagnosed with VRFs based on findings from clinical, radiographic, and cone-beam computerized tomographic (CBCT) examinations. After extraction, VRFs were confirmed in all of the teeth. Deep and narrow periodontal pockets were detected in 2 molars. A widening of the root canal space was observed in the PR of 1 molar only, and crown cracks were detected in none of these cases. However, in all 3 molars, fracture lines were visible on the CBCT images. Thus, CBCT provided useful information in diagnosing VRFs in both endodontically treated and nonendodontically treated teeth, especially when VRFs could not be confirmed by clinical findings and PRs. PMID:21439864

  7. A histological study of retrieved Cambridge acetabular components.

    PubMed

    Brooks, Roger A; Field, Richard E; Jones, Eric; Sood, Asheesh; Rushton, Neil

    2010-01-01

    A new uncemented acetabular component, the Cambridge cup, has been designed to mimic the anatomy and physiology of subchondral bone in order to minimise stress shielding and enhance long-term component stability. Cambridge cups were implanted in a cohort of 50 women who presented with displaced sub-capital fracture of the femoral neck. The cups were manufactured with an hydroxyapatite (HA) coating. Twenty six cups were implanted after removal of the HA. Twelve Cambridge cups were retrieved post-mortem between two and 84 months after implantation. Histological and histomorphometric testing was undertaken to analyse the residual HA coating thickness, bone apposition to the implant surface and particulate wear debris in the surrounding tissues. The HA-coated implants showed significantly greater bone apposition to the implant surface with significantly less fibrous tissue formation than the uncoated implants. Where HA resorption occurred, bone and bone marrow was seen adjacent to the implant. Excessive wear of the ultra high molecular weight polyethylene liner was not seen. The HA-coated components demonstrated good initial bone implant bonding and the flexible carbon polymer appeared to maintain stability following HA resorption. The uncoated implants showed little or no bony apposition but had a fibrous membrane apposed to the implant surface. This may be explained by a combination of micro-motion at the bone implant interface and having a component surface finish that was poorly suited to osseous attachment. Hydroxyapatite coated acetabular components can provide reliable osseous attachment. Subsequent HA resorption need not compromise medium-term osseous fixation to an appropriate implant surface. PMID:20235075

  8. Fractures of the radial head treated by internal fixation: late results in 26 cases.

    PubMed

    Esser, R D; Davis, S; Taavao, T

    1995-01-01

    Twenty-six patients, ranging in age from 14 to 57 years (average 29 years), were evaluated an average of 7 years and 4 months (range 1-14 years) after open reduction and internal fixation of a displaced radial head fracture. Using Mason's classification, there were 11 type II fractures, 9 type III fractures, and 6 type IV fractures with associated dislocation of the elbow. Seven patients had ipsilateral extremity injuries that included fractures of the coronoid process, capitellum, humerus, and distal radius. Using the Broberg and Morrey elbow score, good or excellent results were achieved in all Mason type II and type III fractures. Four of the six Mason type IV fractures were rated good or excellent. Fair results were obtained in two patients who had an associated dislocation of the elbow and multiple ipsilateral extremity injuries. In these two patients, secondary excision of the radial head relieved pain and yielded some improvement in flexion and forearm rotation. PMID:7562154

  9. Influence of coronal restorations on the fracture resistance of root canal-treated premolar and molar teeth: a retrospective study.

    PubMed

    Dammaschke, Till; Nykiel, Kathrin; Sagheri, Darius; Schäfer, Edgar

    2013-08-01

    To evaluate the influence of coronal restorations on the fracture resistance of endodontically treated teeth, 676 root canal-filled and restored posterior teeth were evaluated after a mean period of 9.7 (± 2.8; minimum: 5) years. A total of 86.2% of the endodontically treated and restored teeth survived the mean observation period of 9.7 years without fracture. The overall survival period was 13.6 (± 0.2) years. All teeth with gold partial crowns survived without fractures (n = 24). Teeth with crowns and adhesively sealed access cavities showed a mean survival period of 15.3 (± 0.4) years, with crown and bridge restorations 14.0 (± 0.3), with individual metal posts 13.9 (± 0.2), with composite fillings 13.4 (± 0.5), with prefabricated metal posts 12.7 (± 0.6), with amalgam fillings 11.8 (± 0.6) and with glass ionomer cements (GIC) 6.6 (± 0.5) years. Teeth with one or two surfaces restored by amalgam, composite or GIC showed a significantly lower fracture rate than teeth with three and more restored surfaces (P < 0.05). The mean fracture rate of teeth restored with GIC was significantly higher when compared with all other groups (P < 0.001). In general, endodontically treated teeth restored with prosthetic restorations demonstrated a significantly lower mean fracture rate than teeth restored with fillings. Cavities with up to three surfaces may well be successfully restored adhesively with composite filling material. PMID:23890259

  10. Meralgia Paresthetica and Femoral Acetabular Impingement: A Possible Association

    PubMed Central

    Ahmed, Aiesha

    2010-01-01

    Meralgia paresthetica consists of pain and dysesthesia in the anterolateral thigh. Etiology is divided into spontaneous and iatrogenic causes. To my knowledge this has never been attributed to femoral acetabular impingement. This case highlights the presence of lateral femoral cutaneous neuropathy in the setting of femoral acetabular impingement syndrome thus raising the possibility of an association. Keywords Femoral acetabular impingement; Lateral femoral cutaneous nerve; Dysesthesia; Nerve conduction studies PMID:22043261

  11. Cartilage defect of lunate facet of distal radius after fracture treated with osteochondral autograft from knee.

    PubMed

    Mall, Nathan A; Rubin, David A; Brophy, Robert H; Goldfarb, Charles A

    2013-07-01

    We describe using an osteochondral autograft from the lateral femoral condyle of the knee to treat a symptomatic die-punch lesion of the lunate facet of the distal radius. An 18-year-old woman who sustained a distal radius fracture remained symptomatic after nonoperative treatment and diagnostic wrist arthroscopy with microfracture. We used a commercial harvesting system to transfer an osteochondral plug into a cartilage defect involving the lunate facet of the distal radius. At final follow-up, 34 months after surgery, the patient was assessed with a visual analog scale (VAS) and Disabilities of the Arm, Shoulder, and Hand (DASH) scores and with a comprehensive physical examination. Magnetic resonance arthrogram was used to assess articular cartilage status. VAS pain score improved from 7 before surgery to 0.5 after surgery. Postoperative DASH score was 0. The patient was asymptomatic and had satisfactory wrist motion without mechanical symptoms. Magnetic resonance arthrogram showed the transferred osteochondral autograft incorporated in excellent position. PMID:24078947

  12. Finite element analysis of the impingement on the acetabular liner rim due to wear of the acetabular liner surface

    NASA Astrophysics Data System (ADS)

    Saputra, Eko; Anwar, Iwan Budiwan; Ismail, Rifky; Jamari, J.; van der Heide, Emile

    2016-04-01

    This workstudies the impingement on the rim of acetabular liner due to wear on the surface of acetabular liner using finite element simulation. A three dimensional contact model between a femoral head and an acetabular liner was developed. There are three steps in this simulation, i.e. creating the virtualwear on the surface of acetabular liner, applying the load at the femoral head, and rotating the femoral head from neutral position till the impingement occurrence. The virtualwear is created based on the data of wear depth which was obtained from literature. Results showed that the wear on the acetabular liner surface wouldaffected the impingement occurrence, in which the impingement angle becomes narrow. In addition, the failure possibility of the acetabular liner rimwould become higher.

  13. Retrograde Transpubic Approach for Percutaneous Radiofrequency Ablation and Cementoplasty of Acetabular Metastasis

    PubMed Central

    Bauones, Salem; Freire, Veronique; Moser, Thomas P.

    2015-01-01

    We report a case of painful and disabling anterior acetabular bone metastasis treated with bipolar radiofrequency ablation and cementoplasty. Due to the high risk of complications related to the proximity of the femoral neurovascular structures with a direct approach, we successfully performed a retrograde transpubic approach under combined CT and fluoroscopic guidance. In the present report, we describe this approach detailing its indications, advantages, and the technical tips to achieve a safe and satisfactory procedure. PMID:26491595

  14. Constrained captive acetabular cup for recurrent dislocation of hemiarthroplasty in elderly: A case series

    PubMed Central

    Rajeev, Aysha; Banaszkiewicz, Paul

    2016-01-01

    Introduction Hemiarthroplasty of the hip is one of the commonest procedures done for intracapsular fractures of the neck of femur in elderly. Dislocation of the hemiarthroplasty is a recognised and significant complication. This is associated with considerable morbidity and mortality. The treatment options include closed manipulation, skin and skeletal traction, conversion to total hip replacement, exploration and open reduction and leaving it out of the acetabulum. Presentation of case A retrospective review of ten patients with recurrent and failed closed manipulative reduction of hemiarthroplasty who underwent revision using a cemented captive acetabular cup and cement to cement revision of femoral component with Exeter CDH stem was carried out. The follow up period was two years and the functional outcomes were assessed using Harris hip scores. Discussion The management of recurrent dislocations of hemiarthroplasty in elderly patient are very challenging. Even though various treatment options are described most of them are associated with increased morbidity and mortality and prevent these patients from early mobilisation. The use of captive acetabular avoid repeated dislocations, prolonged bed rest, wearing of a brace and all the complications associated with sustained immobilization. The drawbacks of using constrained cups are hip pain, limited hip movements and loosening. Conclusion We describe a new method of treatment of this difficult condition with a cemented constrained acetabular captive cup and cement to cement revision using a CDH femoral stem. This method prevents further dislocations and will give good functional outcomes thus reducing the high morbidity and mortality. PMID:27129135

  15. Optimal acetabular orientation for hip resurfacing.

    PubMed

    Grammatopoulos, G; Pandit, H; Glyn-Jones, S; McLardy-Smith, P; Gundle, R; Whitwell, D; Gill, H S; Murray, D W

    2010-08-01

    Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47 degrees, 10 degrees to 81 degrees) and anteversion angle (14 degrees, 4 degrees to 34 degrees) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46 degrees (29 degrees to 60 degrees) and 16 degrees (4 degrees to 30 degrees) respectively, but the variation was greater. Assuming an accuracy of implantation of +/- 10 degrees about a target position, the optimal radiographic position was found to be approximately 45 degrees of inclination and 20 degrees of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45 degrees (+/- 10) and anteversion of 20 degrees (+/- 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40 degrees and an anteversion of 25 degrees. PMID:20675749

  16. Bone growth stimulators. New tools for treating bone loss and mending fractures.

    PubMed

    Whitfield, James F; Morley, Paul; Willick, Gordon E

    2002-01-01

    the main focus of this article is necessarily the currently most promising of the anabolic agents, the potent parathyroid hormone (PTH) and certain of its 31- to 38-aminoacid fragments, which are either in or about to be in clinical trial or in the case of Lilly's Forteo [hPTH-(1-34)] tentatively approved by the Food and Drug Administration for treating osteoporosis and mending fractures. PMID:12481542

  17. Diagnosis of Vertical Root Fracture with Cone-Beam Computerized Tomography in Endodontically Treated Teeth: Three Case Reports

    PubMed Central

    Miyagaki, Daniela Cristina; Marion, Jefferson; Randi Ferraz, Caio Cézar

    2013-01-01

    A definitive diagnosis of vertical root fracture (VRF) is often a challenging task for clinicians. This is because two dimensional periapical radiographs are usually unable to detect the fracture line due to the direction of the X-ray beam. This report presents a set of 3 cases of endodontically treated teeth that were diagnosed with VRFs based on findings from clinical, radiographic, and cone-beam computerized tomographic (CBCT) examinations. After extraction, VRFs were confirmed in all cases. The presence of periodontal pockets or other signs which would compromise the correct diagnosis could not be detected in all three cases. Fracture lines were only visible with the aid of CBCT which provided useful information for the diagnosis and management of VRF. However, the clinical and radiographic data should not be discarded, but used in conjunction with CBCT. PMID:23717335

  18. Diagnosis of vertical root fracture with cone-beam computerized tomography in endodontically treated teeth: three case reports.

    PubMed

    Miyagaki, Daniela Cristina; Marion, Jefferson; Randi Ferraz, Caio Cézar

    2013-01-01

    A definitive diagnosis of vertical root fracture (VRF) is often a challenging task for clinicians. This is because two dimensional periapical radiographs are usually unable to detect the fracture line due to the direction of the X-ray beam. This report presents a set of 3 cases of endodontically treated teeth that were diagnosed with VRFs based on findings from clinical, radiographic, and cone-beam computerized tomographic (CBCT) examinations. After extraction, VRFs were confirmed in all cases. The presence of periodontal pockets or other signs which would compromise the correct diagnosis could not be detected in all three cases. Fracture lines were only visible with the aid of CBCT which provided useful information for the diagnosis and management of VRF. However, the clinical and radiographic data should not be discarded, but used in conjunction with CBCT. PMID:23717335

  19. Navigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty

    PubMed Central

    Yoon, Jung-Ro; Yu, Jung Jin; Seo, Hyo-Sung

    2014-01-01

    Purpose To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. Materials and Methods This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation and radiographic data to determine whether the acetabular cup was located within the safe zone or not. To evaluate the clinical outcomes, preoperative and last follow-up Harris hip scores were checked, and the occurrence of complications was evaluated. Results According to the navigation data, the mean inclination and anteversion were 38.5°±4.7°(range, 32°-50°) and 16.6°±4.0°(range, 8°-23°), respectively. According to the radiographic data the mean inclination and anteversion were 40.5°±4.6°(range, 32°-50°) and 19.4°±4.2°(range, 8°-25°), respectively. In both cases, all values were within the safe zone. Harris hip score was improved in all patients from preoperative 52.3±14.4 points (range, 29-87 points) to 88.0±9.0 points (range, 65-99 points) at the last follow-up. There was no dislocation or loosening of both cases. Conclusion Navigated acetabular cup fixation is a useful technique for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty because it prevents the malposition and related complications.

  20. Effect of Post Material and Length on Fracture Resistance of Endodontically Treated Premolars: An In-Vitro Study

    PubMed Central

    Amarnath, G S; Swetha, M U; Muddugangadhar, B C; Sonika, Radhika; Garg, Ashu; Rao, T R Poonam

    2015-01-01

    Background: Endodontically treated teeth with posts are more prone to fracture. Hence, the purpose of this study was to investigate the in-vitro fracture resistance of devitalized teeth and mode of failure restored with posts of different materials and different lengths. Materials and Methods: Sixty freshly extracted human mandibular premolars were endodontically treated and then restored with 1 of 2 prefabricated posts: Stainless-steel (SS) and glass-fiber (fiber posts [FP]) with intraradicular lengths of 4, 5 or 10 mm (n = 10). Following core restoration, a static compressive load was applied perpendicular to the long-axis of the teeth. Initial failure of each specimen was recorded in Newton. The mode of failure was also determined radiographically. The data were analyzed using two-way ANOVA and Tukey's post-hoc analysis with Bonferroni adjustment. Results: Analysis indicated significant differences (P < 0.001) among the groups. Among the SS posts, SS/7 (246 N) exhibited the highest failure load and SS/4 (122 N) the lowest. FP/10 (140.5 N) exhibited the highest failure load among the FP and FP/4 (68.5 N) the lowest. SS posts showed post pull out, followed by core fracture while FP showed core debonding, followed by core fracture as the primary mode of failure. Conclusion: Fracture resistance of the teeth proportionately increased with increase in the length of FP while it decreased with that of metal post. SS posts showed greater fracture resistance than FP when 90° load was applied. PMID:26229366

  1. Rewards & pitfalls of using treating pressure analysis for evaluating fracture design

    SciTech Connect

    Cramer, D.D.

    1996-12-31

    Analyzing pressures during a fracture treatment provides insight into the hydraulic fracturing process, and is widely used today. In this paper, case histories are reviewed and guidelines are presented to identify pitfalls and establish strategies in pressure-analysis methods and procedures.

  2. Atypical femur fracture in an adolescent boy treated with bisphosphonates for X-linked osteoporosis based on PLS3 mutation.

    PubMed

    van de Laarschot, Denise M; Zillikens, M Carola

    2016-10-01

    Long-term use of bisphosphonates has raised concerns about the association with Atypical Femur Fractures (AFFs) that have been reported mainly in postmenopausal women. We report a case of an 18-year-old patient with juvenile osteoporosis based on X-linked osteoporosis due to a PLS3 mutation who developed a low trauma femoral fracture after seven years of intravenous and two years of oral bisphosphonate use, fulfilling the revised ASBMR diagnostic criteria of an AFF. The occurrence of AFFs has not been described previously in children or adolescents. The underlying monogenetic bone disease in our case strengthens the possibility of a genetic predisposition at least in some cases of AFF. We cannot exclude that a transverse fracture of the tibia that also occurred after a minor trauma at age 16 might be part of the same spectrum of atypical fractures related to the use of bisphosphonates. In retrospect our patient experienced prodromal pain prior to both the tibia and the femur fracture. Case reports of atypical fractures in children with a monogenetic bone disease such as Osteogenesis Imperfecta (OI) or juvenile osteoporosis are important to consider in the discussion about optimal duration of bisphosphonate therapy in growing children. In conclusion, this case report 1) highlights that AFFs also occur in adolescents treated with bisphosphonates during childhood and pain in weight-bearing bones can point towards this diagnosis 2) supports other reports suggesting that low trauma fractures of other long bones besides the femur may be related to long-term use of bisphosphonates 3) strengthens the concept of an underlying genetic predisposition in some cases of AFF, now for the first time reported in X-linked osteoporosis due to a mutation in PLS3 and 4) should be considered in decisions about the duration of bisphosphonate therapy in children with congenital bone disorders. PMID:27477003

  3. The Influence of Composite Thickness with or without Fibers on Fracture Resistance of Direct Restorations in Endodontically Treated Teeth

    PubMed Central

    Torabzadeh, Hassan; Ghassemi, Amir; Sanei, Masoud; Razmavar, Sara; Sheikh-Al-Eslamian, Seyedeh Mahsa

    2014-01-01

    Introduction: This in vitro study evaluated the influence of composite thickness (with or without fiber reinforcement) on fracture resistance of direct restorations in endodontically treated teeth. Methods and Materials: Fifty-six intact human premolars were chosen and randomly divided into four groups (n=14). After preparation of a mesio-occluso-distal (MOD) cavities and cusp reduction, the teeth were endodontically treated. Subsequently, the samples were restored with composite resin using the following protocols: group 1; composite onlay with cusp coverage of 1.5 mm, group 2; composite onlay with cusp coverage of 2.5 mm, group 3; composite onlay (including resin-impregnated fiber) with cusp coverage of 1.5 mm and group 4; composite onlay (including resin-impregnated fiber) with cusp coverage of 2.5 mm. The fracture resistance of teeth in all test groups was calculated by subjecting them to a progressively increasing compressive axial force in the universal testing machine with the cross-head speed of 1 mm/min to the point of fracture. The data were analyzed using the Kruskal-Wallis test. Results: The mean fracture strengths and obtained standard error were 1263.85±74.03 N, 1330.26±128.01 N, 1344.92±64.40 N and 1312.54±75.63 N for groups 1 to 4, respectively. Statistical analysis revealed no significant difference between groups. Conclusion: Cusp coverage of 1.5 and 2.5 mm in MOD access cavities with or without insertion of resin impregnated fiber had similar fracture rates in the endodontically treated teeth. PMID:25031597

  4. Management of Symphysis and Parasymphysis Mandibular Fractures in Children Treated with MacLennan Splint: Stability and Early Results

    PubMed Central

    Bhat, Manohar; Sharma, Anupama; Sharma, Rajesh

    2015-01-01

    ABSTRACT Objective: The aim of this study was to assess the safety and efficiency of MacLennan splint in symphysis and parasymphysis mandibular fractures in children. Study design: Six patients (four boys and two girls, mean age 3 years, range between 2 and 5 years) were operated on parasymphysis fractures of children. The mean follow-up time was 12 months. MacLennan splint was applied in these case upto 3 weeks. Results: Primary healing of the fractured mandible was observed in all patients. Postoperative complications were minor and transient. The outcome of the operation was not endangered. Adverse tissue reaction like infection, malocclusion, swelling and growth restrictions did not occur during observation period. Conclusion: MacLennan splint is having various advantages like faster mobilization and the avoidance of secondary removal operations. Based on this preliminary results MacLennan splints are safe and efficient in the treatment of pediatric mandible fracture. How to cite this article: Khairwa A, Bhat M, Sharma A, Sharma R. Management of Symphysis and Parasymphysis Mandibular Fractures in Children Treated with MacLennan Splint: Stability and Early Results. Int J Clin Pediatr Dent 2015;8(2):127-132. PMID:26379381

  5. Comparison of fracture resistance of endodontically treated teeth restored with nanohybrid, silorane, and fiber reinforced composite: An in vitro study

    PubMed Central

    Bilgi, Priyanka Shripad; Shah, Nimisha Chinmay; Patel, Parth Pinakinbhai; Vaid, Deepa S

    2016-01-01

    Background: The present study was undertaken to evaluate the most suitable restorative for badly mutilated endodontically treated teeth. Aims: To evaluate and compare the fracture resistance of endodontically treated premolars restored with conventional nanohybrid, silorane composite with glass fibers and newer fiber-reinforced composite in mesio-occluso-distal (MOD) cavities. Materials and Methods: Sixty extracted human maxillary premolars were selected. Fifteen intact teeth served as positive controls (Group 1). Endodontic therapy was done in the remaining 45 teeth. MOD cavities were prepared in all the teeth with standardized dimensions and were randomly divided into three groups (Group 2 - nanohybrid + glass fibers, Group 3 - silorane + glass fibers, and Group 4 – fiber-reinforced composite). Restorations were done for all groups. Fracture resistance was measured by Instron universal testing machine. Statistical Analysis Used: One-way anova test and Tukey's post hoc test. Results: Highest fracture resistance was shown by intact teeth group followed by fiber-reinforced composite, nanohybrid, and silorane, respectively. Statistically Significant difference was revealed by anova test (P < 0.0001) and Tukey's post hoc test (P < 0.0001). Conclusions: Among the experimental groups, fiber-reinforced composite showed the highest fracture resistance. Statistically significant difference was observed for all the groups. PMID:27563188

  6. A Pediatric Comminuted Talar Fracture Treated by Minimal K-Wire Fixation Without Using a Tourniquet

    PubMed Central

    Inal, Sermet; Inal, Canan

    2014-01-01

    Background Pediatric comminuted talar fractures are reported to be rare, and treatment options such as minimal internal K-wire fixation without using a tourniquet to prevent avascular necrosis have not previously been investigated. Case Description We report a case of a comminuted talar body and a non-displaced neck fracture with dislocation of the tibiotalar, talonavicular and subtalar joints with bimalleolar epiphyseal fractures in an 11-year-old boy due to a fall from height. We present radiological findings, the surgical procedure and clinical outcomes of minimal internal K-wire fixation without using a tourniquet. Literature Review Avascular necrosis rates are reported to be between 0 % and 66 % after fractures of the neck of the talus and the talar body in children. The likelihood of developing avascular necrosis increases with the severity of the fracture. Clinical Relevance To avoid avascular necrosis in a comminuted talar fracture accompanied by tibiotalar, talonavicular, subtalar dislocations and bimalleolar epiphyseal fractures, a minimal internal K-wire fixation without the use of a tourniquet was performed. The outcome was evaluated by the American Orthopedic Foot and Ankle Society score (AOFAS). A score of 90 (excellent) was found at the end of the second year of follow up. Radiology revealed preservation of the joint with no evidence of avascular necrosis, and clinical findings revealed a favorable functional outcome after two years. Level of Evidence 4 PMID:25328479

  7. Inpatient cost of treating osteoporotic fractures in mainland China: a descriptive analysis

    PubMed Central

    Yang, Yicheng; Du, Fen; Ye, Wenyu; Chen, Yu; Li, Jinghu; Zhang, Jie; Nicely, Helen; Burge, Russel

    2015-01-01

    Purpose The objective of this study was to provide new estimates on the per-admission inpatient hospital cost and per-admission length of stay (LOS) for osteoporosis-related fractures in mainland China. Materials and methods Data for inpatient hospitalization associated with at least one osteoporosis-related fracture were obtained from the nationwide China Health Insurance Research Association and were analyzed post hoc. Patients’ data were included if the patients were ≥50 years old and diagnosed with osteoporosis and pathologic fracture, or osteoporosis therapy and fragility fracture by an International Statistical Classification of Diseases and Related Health Problems, 10th Revision (ICD-10) code designation, between 2008 and 2010. Results The analysis included 830 patients (female: 77.3%; mean age: 73.4±9.8 years). The medians of the per-admission LOS and inpatient costs were 19 days and ¥18,587, respectively. Longer LOS and higher costs per admission were associated with older patients (≥70 years) compared to younger patients (<70 years). Hip fracture had the longest median LOS (22 days) and highest median cost (¥32,594) among all fracture sites. The per-hospitalization episode and per-day costs of osteoporotic fracture increased rapidly (60% and 89%, respectively) between 2008 and 2010. Conclusion The analysis showed that hospitalization cost increases were associated with increasing per-day hospitalization costs. The proportion of the costs reimbursed by health insurances increased, while the mean absolute patient copayment amounts decreased. The incidence and prevalence of osteoporosis and osteoporosis-related fractures may rise rapidly due to the projected growth of the aged population in mainland China. Therefore, the combination of greater anticipated total fractures and rising hospital costs may lead to a tremendously increased economic burden in the future. PMID:25926747

  8. Biomechanical Study of Acetabular Tridimensional Memoryalloy Fixation System

    NASA Astrophysics Data System (ADS)

    Liu, Xin-Wei; Xu, Shuo-Gui; Zhang, Yun-Tong; Zhang, Chun-Cai

    2011-07-01

    We developed the acetabular tridimensional memoryalloy fixation system (ATMFS), which is made of NiTi shape memory alloy, according to the specific mechanical properties of biological memory material, NiTi shape memory alloy and measured distribution of contact area and pressure between the acetabulum and the femoral head of cadaveric pelvis. Seven formalin-preserved cadaveric pelves were used for this investigation. Pressure-sensitive film was used to measure contact area and pressure within the anterior, superior, and posterior regions of the acetabulum. The pelves were loaded under the following four conditions: (1) intact; (2) following a creation posterior wall fracture defect; (3) following reduction and standard internal fixation with reconstruction plate; and (4) following reduction and internal fixation with a new shape memory alloy device named ATMFS. A posterior wall fracture was created along an arc of 40° to 90° about the acetabulur rim. Creation of a posterior wall defect resulted in increased load in the superior acetabulum (1485 N) as compared to the intact condition (748 N, P = 0.009). Following reduction and internal fixation, the load distributed to the superior acetabulum (1545 N) was not statistically different from the defect condition. Following the fixation with ATMFS, the load seen at the superior region of the actabulum (964 N) was familiar with fixation with reconstruction plate and was not different from intact state ( P = 0.45). These data indicate that the use of ATMFS as a fracture internal fixation device resulted a partial restoration of joint loading parameters toward the intact state. ATMFS fixation may result in a clinical benefit.

  9. Effect of Retained Austenite on the Fracture Toughness of Quenching and Partitioning (Q&P)-Treated Sheet Steels

    NASA Astrophysics Data System (ADS)

    Wu, Riming; Li, Wei; Zhou, Shu; Zhong, Yong; Wang, Li; Jin, Xuejun

    2014-04-01

    Fracture toughness K IC was measured by double edge-notched tension (DENT) specimens with fatigue precracks on quenching and partitioning (Q&P)-treated high-strength (ultimate tensile strength [UTS] superior to 1200 MPa) sheet steels consisting of 4 to 10 vol pct of retained austenite. Crack extension force, G IC, evaluated from the measured K IC, is used to analyze the role of retained austenite in different fracture behavior. Meanwhile, G IC is deduced by a constructed model based on energy absorption by martensite transformation (MT) behavior of retained austenite in Q&P-treated steels. The tendency of the change of two results is in good agreement. The Q&P-treated steel, quenched at 573 K (300 °C), then partitioned at 573 K (300 °C), holding for 60 seconds, has a fracture toughness of 74.1 MPa·m1/2, which is 32 pct higher than quenching and tempering steel (55.9 MPa·m1/2), and 16 pct higher than quenching and austempering (QAT) steel (63.8 MPa·m1/2). MT is found to occur preferentially at the tips of extension cracks on less stable retained austenite, which further improves the toughness of Q&P steels; on the contrary, the MT that occurs at more stable retained austenite has a detrimental effect on toughness.

  10. Hip Arthroscopy in the Presence of Acetabular Dysplasia

    PubMed Central

    Jayasekera, Narlaka; Aprato, Alessandro; Villar, Richard N

    2015-01-01

    Purpose : Hip arthroscopy is a well established therapeutic intervention for an increasing number of painful hip conditions. Developmental dysplasia of the hip (DDH) is commonly associated with intra-articular hip pathology. However, some surgeons perceive patients with hip dysplasia as poor candidates for hip arthroscopy. Our aim was to describe early outcomes of arthroscopic treatment for patients with DDH, who also had femoroacetabular impingement (FAI) treated when necessary, and to compare these outcomes against a control group of patients without DDH. Methods : Prospective case-control study of 68 consecutive hip arthroscopy patients assessed with a modified Harris Hip Score (mHHS) preoperatively and at six weeks, six months, and one year after surgery. Presence of DDH was determined using a standard anteroposterior (AP) pelvic radiograph to measure the centre-edge angle (CEA) of Wiberg, with a CEA < 20º used as threshold for diagnosis of DDH. Results : 12 patients (eight female and four male) with acetabular dysplasia and mean CEA of 15.4º (9º to 19º). The control, nondysplastic group comprised 54 patients (23 females and 31 males) with a mean CEA of 33.1º (22º to 45º). All patients in the dysplastic group had a labral tear and 11 (91.7%) had associated femoral cam impingement lesion addressed at arthroscopy. Our study demonstrates a significant (p=0.02) improvement in outcome in the dysplastic group at one year using the mHHS. Conclusion : Hip arthroscopy in the presence of DDH is effective in relieving pain for at least one year after surgery although does not address underlying acetabular abnormality. PMID:26069512

  11. Fracture resistance of endodontically treated maxillary central incisors with varying ferrule heights and configurations: In vitro study

    PubMed Central

    Singh, Smita; Thareja, Prerna

    2014-01-01

    Objective: The objective of this study is to determine the best ferrule configuration of endodontically treated teeth. Materials and Methods: A total of 40 freshly extracted maxillary central incisors were collected. Teeth were allocated into following four groups of each having 10 teeth. Group 1 teeth restored with crowns (CRN), Group 2 endodontically treated teeth restored with crowns (RCT and CRN), Group 3 endodontically treated teeth restored with cast dowel cores and crowns incorporating uniform 2 mm ferrule (2 FRL), Group 4 endodontically treated teeth restored with cast dowel cores and crowns incorporating uniform 1 mm ferrule (1 FRL). Crown preparation was performed with varying ferrule heights, crowns were cemented with resin modified glass ionomer cement and were kept in 100% humidity for 3 days, all specimens were loaded to failure in a universal testing machine at 0.5 mm/min. Results were obtained in the form of kilo Newton and Newton. Result: The statistical analysis applied was an analysis of variance to detect the presence of group differences. Pair wise comparisons between the groups were analyzed with the Tukey Kramer significant difference test for multiple comparisons. Conclusion: Ferrule had a significant role in the fracture resistance of custom cast post core restored teeth. Endodontically treated maxillary central incisors with a uniform 2 mm ferrule were more fracture resistant than those with a uniform 1 mm ferrule. PMID:24778504

  12. Proximal Femoral Nail Antirotation Versus Reverse Less Invasive Stabilization System-distal Femur for Treating Proximal Femoral Fractures

    PubMed Central

    Jiang, Xuan; Wang, Ying; Ma, XinLong; Ma, JianXiong; Wang, Chen; Zhang, ChengBao; Han, Zhe; Sun, Lei; Lu, Bin

    2016-01-01

    Abstract The aim of this study was to compare the effectiveness and safety of 2 surgical techniques that are used to treat proximal femoral fractures. A systematic literature search (up to December 2014) was conducted in Medline, Embase, PubMed, and The Cochrane Central Register of Controlled Trials to screen for studies comparing proximal femoral nail antirotation (PFNA) with less invasive stabilization system–distal femur (LISS-DF) for proximal femoral fractures. Two authors independently assessed the methodological quality of the included studies and extracted data. Surgical information and postoperative outcomes were analyzed. A total of 7 studies with 361 patients who satisfied the eligibility criteria included 3 randomized controlled trials and 4 case-controlled trials associated with PFNA versus LISS in treating proximal femoral fractures. Our results demonstrated that there was a significant reduction in hospital stay and time to weight-bearing ambulation and bone healing for PFNA compared with LISS (odds ratio [OR] −1.48, 95% confidence interval [CI] −2.92 to −0.05; OR −7.08, 95% CI −8.32 to −5.84; OR −2.71, 95% CI −4.76 to 0.67). No statistically significant difference was observed between the 2 groups for operative time, blood loss volume, Harris hip score, and incidence of complications. Based on the results of this analysis, we inferred that PFNA is safer and more effective than reverse LISS-DF in patients undergoing osteosynthesis for proximal femoral fractures, and that PFNA is associated with reduced hospital stays and reduced time to weight-bearing ambulation and bone healing. Nonetheless, in certain cases in which PFNA is not suitable due to abnormal structure of the proximal femur or particularly unstable fractures, the LISS plate technique could be a useful alternative. PMID:27057840

  13. The treatment of complex proximal humeral fractures: analysis of the results of 55 cases treated with PHILOS plate.

    PubMed

    Fattoretto, D; Borgo, A; Iacobellis, C

    2016-08-01

    Complex proximal humerus fractures are often difficult to treat. Their frequency is high, especially in the elderly, and their treatment is still controversial. The aim of this study was to analyze the clinical and radiological results achieved by patients with complex proximal humerus fractures, treated with PHILOS plate only. A cohort of 55 patients was selected. The mean age was 63.4 (range 33-89), while the mean follow-up time was 21.5 months (range 6-75). Clinical outcome was evaluated with the "Constant-Murley shoulder score." All the informations about the presence of complications were gathered, and radiological images were used to calculate the head-shaft angle. The overall mean Constant score was 61.93 ± 18.59, the Individual CS was 70 ± 20 % and the Relative CS was 83 ± 23 %. No significant differences were found between fractures Neer 3 and Neer 4 and between the surgical approaches (delta-split vs. delto-pectoral). Six patients had a fracture with dislocation, seven patients (12.7 %) had complications while in four patients a head-shaft angle beyond the normal range was found. Osteosynthesis with PHILOS plate is stable in the greater part of the cases, and it allows an earlier rehabilitation and so a good functional result, which could be compromised by a prolonged immobilization. Therefore, PHILOS plate is a good option for the treatment of complex proximal humerus fractures. PMID:26833189

  14. Unusual Cause of Hip Pain: Intrusion of the Acetabular Labrum

    PubMed Central

    Jang, Se-Ang; Byun, Young-Soo; Jeong, Dae-Geun; Han, In-Ho; Kim, Min-Guek

    2015-01-01

    Femoroacetabular impingement and dysplatic hip joint is well known cause of osteoarthritis. In these diseases, labral tear and subsequent cartilage damage is thought to be main pathophysiology of development of osteoarthritis. If there are no known bony abnormalities, we called it as idiopathic osteoarthritis. Normal appearance of acetabular labrum is a continuous, usually triangular structure that attaches to the bony rim of the acetabulum and is completed at the inferior portion by the transverse acetabular ligament over the acetabular notch. A few authors reported intra-articular labrum and its relation to the development of osteoarthritis. But they didn't comment the primary bony abnormality especially acetabulum. We'd like to report x-ray, computed tomogram, magnetic resonance arthrogram and arthroscopic findings of a case had double contour sign of acetabular dome combined with intrusion of acetabular labrum.

  15. The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.

    PubMed

    Lachiewicz, P F; Watters, T S

    2016-01-01

    The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. PMID:26733644

  16. Fracture Strength of Endodontically Treated Teeth Restored with Casting Post and Core and Glass-Fiber with Composite Core

    PubMed Central

    Saatian, Sedigheh

    2006-01-01

    INTRODUCTION: Prefabricated metal and ceramic posts can be used with different kinds of core materials as an alternative to the conventional casting post and cores. It is unclear how these post and core systems can withstand different kind of forces in the mouth. The purpose of this study was to compare the fracture strength of endodontically treated, crowned maxillary incisors restored with casting post and cores and glass- fiber post with composite core and to evaluate their mode of fractures. MATERIALS AND METHODS: Thirty caries free, human maxillary central incisors with incisoapical length of 23 ± 1 mm were divided into two groups. After root canal treatment procedures and decronation of teeth 2mm above cementoenamel junction, Grope 1 was restored with glass- fiber posts and composite cores and group 2 received casting post and cores. Teeth were prepared with a circumferential shoulder including a 1-2 mm ferrule and 0.5 mm bevel; all posts were cemented with an adhesive resin and teeth were restored with complete coverage crowns. Loads were applied at an angle of 135 degrees using a universal testing machine. Compression force was applied until the specimens fractured. RESULTS: The median fracture strengths of groups 1 and 2 were 459 and 686 respectively (p<0.5). In group I, all fractures occurred in incisal third of roots. In groups II, 40% of fractures were in apical third and middle of roots. CONCLUSION: Within the limitation of this study, the results suggested that glass fiber with composite cores can be used as an alternative to cast posts and cores in anterior teeth when creating 2mm ferrule effect was possible in normal occlusion. Clinical trial is required to verify these in vitro results. PMID:24470803

  17. Cement Calcaneoplasty: An Innovative Method for Treating Nonunion in Calcaneal Insufficiency Fracture.

    PubMed

    Godavitarne, Charles; Fawzy, Ernest; Giancola, Giorgio; Louette, Luc

    2016-01-01

    Insufficiency type stress fractures are common in older patients with osteoporosis. Persistent pain after nonunion of these fractures can be disabling, with the management options often limited. We aimed to assess the suitability of fluoroscopic-guided injection of bone cement into a persistently symptomatic nonuniting calcaneal insufficiency fracture. To the best of our knowledge, this technique has not previously been described in the published data. After local subcutaneous anesthesia, the midpoint of the fracture site was accessed by trocar insertion under radiographic guidance, and bone cement was injected directly into the site. A preprocedure visual analog scale pain score of 90 of 100 was recorded. This had improved to 0 of 100 at the 12-month follow-up point after the procedure. The aim of the present case report was to raise awareness of percutaneous calcaneoplasty, which we believe to be a safe and well-tolerated technique for the management of osteoporotic insufficiency fracture of the calcaneus. We propose that this technique be considered when conservative methods aimed at promoting fracture healing have failed. PMID:26875768

  18. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups.

    PubMed

    Smith, S L; Ash, H E; Unsworth, A

    2000-01-01

    A novel design of polyurethane compliant layer acetabular cup has been developed through a series of friction, creep and wear tests. Friction tests were initially conducted on ABG standard form, polyurethane acetabular cups and an ABG standard form, UHMWPE acetabular cup for comparison. The polyurethane cups showed lower friction than the UHMWPE cup with maximum friction factors between 0. 008 and 0.02 compared with 0.035 for the UHMWPE cup. This indicated that, in the polyurethane cups, more of the load across the joint was carried by the fluid entrapped in the joint space rather than with asperity contact, compared with the UHMWPE cup. The inherent compliance of the polyurethane is used to promote elasto-hydrodynamic lubrication. However, this compliance raised concerns over excessive creep, which may in turn adversely affect tribological performance. Therefore, creep tests were undertaken on the ABG standard form, polyurethane acetabular cups followed by further friction tests. Small amounts of creep occurred in the polyurethane cups at ambient temperature, which reduced the friction slightly (maximum friction factors of 0.009) due to increased conformity between the head and the cup. However, at 37 degrees C, greater creep occurred causing pinching of the femoral head by the acetabular cup resulting in lubricant starvation and higher friction (maximum friction factors of 0.035). The design of the polyurethane cups was subsequently modified to incorporate a flared rim to eliminate the possibility of fluid starvation through pinching. Creep in polyurethane acetabular cups is also affected by the method of fixation of the cups, due to the conformity with and the stiffness of the cup backing. Hence, a one-million-cycle wear test was performed on five ABG flared form, polyurethane acetabular cups on the Mk. I Durham Hip Joint Wear Simulator to evaluate the best method of fixation for the polyurethane cups. The smallest amount of penetration, due to creep and wear

  19. Clinical and Radiologic Outcomes among Bipolar Hemiarthroplasty, Compression Hip Screw and Proximal Femur Nail Antirotation in Treating Comminuted Intertrochanteric Fractures

    PubMed Central

    Suh, You-Sung; Nho, Jae-Hwi; Kim, Seong-Min; Hong, Sijohn; Choi, Hyung-Suk

    2015-01-01

    Purpose In comminuted intertrochanteric fractures, various operative options have been introduced. The purpose of this study was to determine whether there were differences in clinical and radiologic outcomes among bipolar hemiarthroplasty (BH), compression hip screw (CHS) and proximal femur nail antirotation (PFNA) in treating comminuted intertrochanteric fractures (AO/OTA classification, A2 [22, 23]) Materials and Methods We retrospectively evaluated total 150 patients (BH, 50; CHS, 50; PFNA, 50) who were operated due to intertrochanteric fractures from March 2010 to December 2012 and were older than 65 years at the time of surgery. We compared these three groups for radiologic and clinical outcomes at 12 months postoperatively, including Harris Hip Score, mobility (Koval stage), visual analogue scale and radiologic limb length discrepancy (shortening). Results There was no statistical significance among three groups in clinical outcomes including Harris Hip Score, mobility (Koval stage), visual analogue scale. However, there was significant differences in radiologic limb discrepancy in plain radiographs at 12 months postoperatively (radiologic shortening: BH, 2.3 mm; CHS, 5.1 mm; PFNA, 3.0 mm; P=0.000). Conclusion There were no clinical differences among BH, PFNA, and CHS in this study. However, notable limb length shortening could be originated during fracture healing in osteosynthesis, compared to arthroplasty (BH

  20. Bone Repair on Fractures Treated with Osteosynthesis, ir Laser, Bone Graft and Guided Bone Regeneration: Histomorfometric Study

    NASA Astrophysics Data System (ADS)

    dos Santos Aciole, Jouber Mateus; dos Santos Aciole, Gilberth Tadeu; Soares, Luiz Guilherme Pinheiro; Barbosa, Artur Felipe Santos; Santos, Jean Nunes; Pinheiro, Antonio Luiz Barbosa

    2011-08-01

    The aim of this study was to evaluate, through the analysis of histomorfometric, the repair of complete tibial fracture in rabbits fixed with osteosynthesis, treated or not with infrared laser light (λ780 nm, 50 mW, CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical fractures were created, under general anesthesia (Ketamina 0,4 ml/Kg IP and Xilazina 0,2 ml/Kg IP), on the dorsum of 15 Oryctolagus rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with wire osteosynthesis. Animals of groups III and V were grafted with hydroxyapatite and GBR technique used. Animals of groups IV and V were irradiated at every other day during two weeks (16 J/cm2, 4×4 J/cm2). Observation time was that of 30 days. After animal death (overdose of general anesthetics) the specimes were routinely processed to wax and underwent histological analysis by light microscopy. The histomorfometric analysis showed an increased bone neoformation, increased collagen deposition, less reabsorption and inflammation when laser was associated to the HATCP. It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of CHA.

  1. The Management of a Persistent Periapical Lesion Caused by an Apicomarginal Defect, Associated with a Root End Fracture in an Endodontically Treated Tooth: A Clinical Report

    PubMed Central

    S., Shruthi; Patel, Punit Vaibhav; Kumar, Sheela

    2012-01-01

    This is a case report of the presentation and the management of an apicomarginal defect which was associated with a root end fracture in an endodontically treated tooth. In spite of a successful Root Canal Treatment (RCT), if the fractured root end is left intact, considering inadverdent ankylosis or resorption, it may progress to the development of a bony dehiscence. PMID:23285470

  2. An Effective Approach for Optimization of a Composite Intramedullary Nail for Treating Femoral Shaft Fractures.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2015-12-01

    The high stiffness of conventional intramedullary (IM) nails may result in stress shielding and subsequent bone loss following healing in long bone fractures. It can also delay union by reducing compressive loads at the fracture site, thereby inhibiting secondary bone healing. This paper introduces a new approach for the optimization of a fiber-reinforced composite nail made of carbon fiber (CF)/epoxy based on a combination of the classical laminate theory, beam theory, finite-element (FE) method, and bone remodeling model using irreversible thermodynamics. The optimization began by altering the composite stacking sequence and thickness to minimize axial stiffness, while maximizing torsional stiffness for a given range of bending stiffnesses. The selected candidates for the seven intervals of bending stiffness were then examined in an experimentally validated FE model to evaluate their mechanical performance in transverse and oblique femoral shaft fractures. It was found that the composite nail having an axial stiffness of 3.70 MN and bending and torsional stiffnesses of 70.3 and 70.9 N⋅m², respectively, showed an overall superiority compared to the other configurations. It increased compression at the fracture site by 344.9 N (31%) on average, while maintaining fracture stability through an average increase of only 0.6 mm (49%) in fracture shear movement in transverse and oblique fractures when compared to a conventional titanium-alloy nail. The long-term results obtained from the bone remodeling model suggest that the proposed composite IM nail reduces bone loss in the femoral shaft from 7.9% to 3.5% when compared to a conventional titanium-alloy nail. This study proposes a number of practical guidelines for the design of composite IM nails. PMID:26458035

  3. Comparison of Functional Outcomes of Tibial Plateau Fractures Treated with Nonlocking and Locking Plate Fixations: A Nonrandomized Clinical Trial

    PubMed Central

    Tahririan, Mohammad Ali; Mousavitadi, Seyyed Hamid; Derakhshan, Mohsen

    2014-01-01

    Fixation of tibial plateau fractures with plate has been widely used. This prospective study was planned to compare locking plate fixation of tibial plateau fracture with nonlocking methods in terms of their functional outcomes. The subjects of the study were selected from consecutive patients suffering from tibial plateau fractures referred to Kashani Hospital in Isfahan, Iran, between 2012 and 2013 and were candidate for surgery. The final included patients were assigned to two groups, those who were treated with locking plate (n = 20) and those who were treated with nonlocking plates (N = 21). The mean duration of follow-up was 13.4 months (ranging between 10 and 17 months). The mean of knee scores was significantly higher in locking plate group than in nonlocking plate group at the follow-up time (80.20 ± 10.21 versus 72.52 ± 14.75, P = 0.039). Also, the mean VAS pain severity score was significantly lower in locking plate group compared with nonlocking plate group (4.45 ± 2.50 versus 6.00 ± 2.59, P = 0.046). This study confirmed superiority of the locking plate method over nonlocking plate method with regard to knee score as well as VAS pain score. PMID:24967126

  4. Radiological predictive factors for the outcome of surgically treated calcaneus fractures.

    PubMed

    Baptista, Mário; Pinto, Rui; Torres, João

    2015-06-01

    Calcaneus fractures are fairly common and clinically relevant due to their poor outcome. Thus, solving the controversy regarding treatment and outcome prediction should be a target. This study intends to evaluate the predictive ability of common radiologic tools for the surgical outcome of calcaneus fractures, regardless of treatment modality. 44 patients' records, with operated calcaneus fractures between 2008 and 2013, were retrospectively assessed and imagiology was blindly evaluated. Patients were submitted to percutaneous or open lateral approach. No relevant correlations were found between the measurements on the plain lateral radiograph and the outcome. Fractures were also graded according to the Sanders classification. Type 4 fractures predicted the occurrence of any hazard, such as skin or pain related complications and need for secondary surgery (p=0.051, odds=14.00 [CI=1.30-150.89]). However, it's still not possible to accurately target patients with high risk of postoperative complications. Until then, follow-up protocols should be maintained indiscriminately. PMID:26280959

  5. Factors Affecting Time to Bony Union of Femoral Subtrochanteric Fractures Treated with Intramedullary Devices

    PubMed Central

    Choi, Jung-Yoon; Yoo, Jin-Hee; Chung, Sung-Jae

    2014-01-01

    Purpose To evaluate the factors affecting the bone union time and the occurrence of nonunion after intramedullary nailing of subtrochanteric femoral fractures in adults. Materials and Methods We retrospectively reviewed data from 31 patients (22 men and 9 women) who had undergone femoral intramedullary nailing at least 1 year post-operatively and analyzed the bone union time, nonunion rates, and factors that affected the bone union time according to the fracture classification (AO and Fielding classifications), comminution of the medial cortex, reduction method, and additional cerclage wiring. Results The average union time was 26.4 weeks. There were no differences in the bone union time according to the fracture classification, reduction method, or additional cerclage wiring. Significant differences were found in the bone union time between the medial cortex comminution and non-comminution groups. A relatively strong positive correlation was detected between the degree of post-operative displacement and the bone union time. Nonunion occurred in three cases and there was no failure of implants. Conclusion The bone union time was not affected by the reduction method nor additional cerclage wiring in intramedullary nailing of subtrochanteric femur fractures. Comminution of the medial cortex and the degree of the postoperative displacement of fractures contributed to the delayed time of union.

  6. Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth

    PubMed Central

    Bechara, B; Alex McMahan, C; Moore, WS; Noujeim, M; Teixeira, FB; Geha, H

    2013-01-01

    Objectives: Cone beam CT (CBCT) is used widely to depict root fracture (RF) in endodontically treated teeth. Beam hardening and other artefacts due to gutta-percha may increase the time of the diagnosis and result in an incorrect diagnosis. Two CBCT machines, ProMax® (Planmeca, Helsinki, Finland) and Master 3D® (Vatech, Hwaseong, Republic of Korea), have the option of applying an artefact reduction (AR) algorithm. The aim of this study was to determine whether using an AR algorithm in two CBCT machines enhances the accuracy of detecting RFs in endodontically treated teeth. Methods: 66 roots were collected and decoronated. All roots were treated endodontically using the same technique with gutta-percha and zinc oxide cement. One-half of the roots were randomly selected and fractured using a nail that was tapped gently with a hammer until complete fracture resulted in two root fragments; the two root fragments were glued together with one layer of methyl methacrylate. The roots were placed randomly in eight prepared beef rib fragments. Results: The highest accuracy was obtained when the ProMax was used without AR. The lowest accuracy was obtained with the Master 3D when used with AR. For both machines, accuracy was significantly higher without AR than with AR. Both with and without AR, the ProMax machine was significantly more accurate than the Master 3D machine. The same rank ordering was obtained for both sensitivity and specificity. Conclusions: For both machines, AR decreased the accuracy of RF detection in endodontically treated teeth. The highest accuracy was obtained when using the ProMax without AR. PMID:23520395

  7. Role of Dentin Compositional Changes and Structural Loss on Fracture Predilection in Endodontically Treated Teeth

    NASA Astrophysics Data System (ADS)

    Ossareh, Arezou

    The aim of this study was to examine the role of chemical compositional changes and iatrogenic dentin structural loss on the mechanical response of teeth to force and resistance to fracture. The experiments were divided into three phases. In phase 1, experimental studies were performed to evaluate the effect of chemicals used during treatment on ultrastructure, composition and resistance to fracture of dentin. In phase 2, experimental studies were used to evaluate the influence of dentin removal and remaining dentin volume on the resistance to fracture and microcrack formation in root dentin. In phase 3 finite element analysis was carried out to examine the influence of dentin loss on the stress distribution in root dentin. The combination of experimental and numerical analysis highlighted the role of remaining dentin volume and moment of inertia on root dentin biomechanics.

  8. Ten-year incidence and risk factors of bone fractures in a cohort of treated HIV1-infected adults

    PubMed Central

    Collin, Fidéline; Duval, Xavier; Lemoing, Vincent; Piroth, Lionel; Al Kaied, Firas; Massip, Patrice; Villes, Virginie; Chêne, Geneviève; Raffi, François

    2009-01-01

    In the ANRS CO8 APROCO-COPILOTE cohort of patients treated with combination antiretroviral therapy since 1997–1999, the incidence density of bone fractures was 3.3 for 1,000 patient-years (95% CI: 2.0–4.6). Rate was 2.9-fold (95% CI: 1.3–6.5) higher among patients with excessive alcohol consumption and 3.6-fold (95% CI: 1.6–8.1) higher in those with Hepatitis C virus (HCV) co-infection. Specific monitoring of HCV/HIV-coinfected patients and active promotion of alcohol cessation should be recommended for the prevention of bone fractures. PMID:19300202

  9. Fracture strength of endodontically-treated teeth restored with post and cores and composite cores only.

    PubMed

    Ozcan, M; Valandro, L F

    2009-01-01

    This study compared the fracture strength of different conditioned metallic posts, fiber-reinforced-composite posts and composite cores only in teeth without coronal tooth structure and determined failure modes after the fracture test. Post spaces were prepared in the root canals, and the teeth were randomly divided into seven experimental groups: Gr1: Titanium posts (ParaPost) + Silano-Pen (Bredent) + silane; Gr2: Titanium posts + 30 microm CoJet-Sand (3M ESPE) + silane; Gr3: Titanium posts + 50 microm Al2O3 + V-primer (Sun Medical); Gr4: Titanium posts + 50 microm Al2O3 + Alloy primer (Kuraray); Gr5: E-glass FRC post (EverStick); Gr6: Polyethylene fiber (Ribbond) + Resin impregnation and Gr7: Resin composite core only, with no posts. The posts were cemented using Panavia F 2.0 (Kuraray); coronal parts of the roots were etched, primed, bonded and composite cores were built-up. After thermocycling (5 degrees C-55 degrees C, 6000x), the fracture strength test was performed. The fracture strength of titanium posts (408 +/- 122 - 550 +/- 149 N) was significantly higher (p<0.05) than that of FRC posts (321 +/- 131 and 267 +/- 108 N for Everstick and Ribbond, respectively) or the group without posts (175 +/- 70 N) (Gr7) (ANOVA, Tukey's test). The group without posts resulted in complete core detachment (100%). In the E-glass FRC group, 60% adhesive core fracture occurred, covering >1/3 of the core and, in the polyethylene FRC group, 100% post-core detachment at the canal opening was observed. In all the titanium post applied groups (Gr1-Gr4), the posts remained in place with partial detachment of the core material from the post surface at varying degrees, depending on the conditioning method used. When no coronal tooth structure exist, the metal posts showed higher fracture strength values as opposed to the FRC post or no-post approach. PMID:19678448

  10. Effect of Intra-Orifice Barriers on the Fracture Resistance of Endodontically Treated Teeth – An Ex-Vivo Study

    PubMed Central

    Aboobaker, Shaheen; Gopal, Rajesh; Jituri, Sandeep; Veetil, Fazalu Rahman Pothu

    2015-01-01

    Introduction: The purpose of this study was to evaluate and compare the fracture resistance of roots obturated with guttapercha using bonded amalgam, GC Light cure GIC (resin modified glass ionomer cement) and Tetric N Flow (flowable hybrid composite) as different intra orifice barriers. Materials and Methods: Eighty freshly extracted mandibular premolars with straight roots were reduced to 14 mm from the coronal aspect. All canals were enlarged to size 30 and specimens were obturated with gutta percha cones, except for control group specimens the coronal 3 mm of root fillings of all other group specimens were removed with the aid of heated plugger. All samples were randomly divided into 4 groups of 20 specimens each. They were control, Fuji GC LC GIC, Tetric N Flow and Bonded Amalgam. After the placement of the intra orifice barrier materials, specimens stored at 37oC and 100% humidity for one week to allow the materials to set completely. After one week, all the groups were subjected to fracture resistance testing by using Universal testing machine. Results: Data was analysed for significance by ANOVA (Analysis of variance) and further pair wise comparison was performed by Benferroni test. Level of significance was taken as 0.05. Tetric N Flow group showed better fracture resistance as compared to all other groups and Control group is least among the groups. Fracture resistance of Tetric N Flow compared with bonded amalgam was statistically significant. Conclusion: Tetric N Flow and Fuji GC LC GIC can be used as intra-orifice barriers with good fracture resistance in endodontically treated teeth. PMID:25859518

  11. [Analysis of the Basic Stress Pathway Above Acetabular Dome].

    PubMed

    Nie, Yong; Ma, Jun; Haung, Qiang; Hu, Qinsheng; Shi, Xiaojun; Pei, Fuxing

    2015-08-01

    The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in acetabular reconstruction of total hip arthroplasty (THA). The purpose of this study was to describe the basic stress pathway to provide evidence for clinical acetabular reconstruction guidance of THA. A subject-specific finite element (FE) model was developed from CT data to generate 3 normal hip models and a convergence study was conducted to determine the number of pelvic trabecular bone material properties using 5 material assignment plans. In addition, in the range of 0 to 20 mm above the acetabular dome, the models were sectioned and the stress pathway was defined as two parts, i.e., 3D, trabecular bone stress distribution and quantified cortical bone stress level. The results showed that using 100 materials to define the material property of pelvic trabecular bone could assure both the accuracy and efficiency of the FE model. Under the same body weight condition, the 3D trabecular bone stress distributions above the acetabular dome were consistent, and especially the quantified cortical bone stress levels were all above 20 MPa and showed no statistically significant difference (P>0.05). Therefore, defining the basic stress pathway above the acetabular dome under certain body weight condition contributes to design accurate preoperative plan for acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants. PMID:26710451

  12. The effect of different full-coverage crown systems on fracture resistance and failure pattern of endodontically treated maxillary incisors restored with and without glass fiber posts.

    PubMed

    Salameh, Ziad; Sorrentino, Roberto; Ounsi, Hani F; Sadig, Walid; Atiyeh, Fadi; Ferrari, Marco

    2008-07-01

    The aim of this study was to compare the fracture resistance and failure pattern of endodontically treated maxillary incisors restored using composite resin with or without fiber-reinforced composite (FRC) posts under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of FRC posts or by the type of full-coverage crown. One hundred twenty maxillary incisors were endodontically treated and divided into 4 groups of 30 each. Each group was divided into two subgroups: restoration with or without fiber post. PFM crowns were placed in group 1, Empress II crowns in group 2, SR Adoro crowns in group 3, and Cercon crowns in group 4. Fracture tests were performed by loading specimens to fracture. Data were analyzed with two-way analysis of variance (alpha = 0.05). The type of crown was not a significant factor affecting fracture resistance (p = 0.4), whereas the presence of a post was (p = 0.001). Both the presence of post and the type of crown had a significant influence on the proportion of restorable versus unrestorable fractures. Although prosthodontics textbooks do not generally advocate the placement of fiber posts in endodontically treated incisors, the results of this study indicate that the use of fiber posts in such teeth increases their resistance to fracture and improves the prognosis in case of fracture. PMID:18570992

  13. Epidemiology and treatment outcome of surgically treated mandibular condyle fractures. A five years retrospective study.

    PubMed

    Zrounba, Hugues; Lutz, Jean-Christophe; Zink, Simone; Wilk, Astrid

    2014-09-01

    Surgical management of mandibular condyle fractures is still controversial. Although it provides better outcome than closed treatment questions still remain about the surgical approach and the osteosynthesis devices to be used. Between 2005 and 2010, we managed 168 mandibular condyle fractures with open treatment. Two surgical approaches were used in this study, a pre-auricular and a high submandibular approach (one or the other or as a combined approach). Internal fixation was performed using TCP(®) plates (Medartis, Basel, Switzerland) or with two lag screws (15 and 17 mm). Delta plates were used in 15 cases (8.9%). We report the epidemiology of these fractures and the outcomes of the surgical treatment. We assessed the complications related to the surgical procedure and those related to the osteosynthesis material. The facial nerve related complication rate was very low and the osteosynthesis materials used proved to be strong enough to realize a stable fixation. The two approaches used in this study appeared to be safe with good aesthetic results. Most of the surgical procedure failures occurred in high subcondylar fractures especially when bilateral. PMID:24485271

  14. Comminuted radial head fractures treated by the Acumed anatomic radial head system

    PubMed Central

    Mou, Zhefei; Chen, Maohua; Xiong, Yan; Fan, Zhihang; Wang, Aimin; Wang, Ziming

    2015-01-01

    Objective: The treatment of comminuted radial head fractures is still challenging. A radial head replacement is more effective in comminuted radial head fractures. The aim of this paper was to present the medium-term results of the Acumed anatomic radial head system (AARHS). Methods: This study was performed on 12 patients with traumatic elbow fracture and instability between 2008 and 2011 of whom 12 were reviewed at a mean follow-up of 60.8 months (19 to 77 months). The evaluation included a record of pain, function, muscle strength, contracture and rotation. The outcome was assessed using the Hospital for Special Surgery total elbow scoring and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. Results: The average flexion and extension arc was 130° (range, 110° to 140°). The mean range of elbow supination was 75° (rang, 60° to 85°) and pronation 80° (range, 65° to 90°). There were no complications such as infection, implant loosening, instability of the elbow, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. The mean DASH score was 11.9/100 (0 to 25/100). Conclusion: The radial head replacement with the AARHS can provide effectively stability and good clinic results at the middle term following up. Our experience has encouraged us to continue using the AARHS in comminuted fractures, especially when instability of elbow is a potential problem. PMID:26131250

  15. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    PubMed Central

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  16. The effect of ferrule presence and type of dowel on fracture resistance of endodontically treated teeth restored with metal-ceramic crowns

    PubMed Central

    Aggarwal, Vivek; Singla, Mamta; Yadav, Suman; Yadav, Harish; Sharma, Vikram; Bhasin, Saranjit Singh

    2014-01-01

    Aim: The purpose of the present study was to comparatively evaluate the effect of presence of a 2 mm ferrule and different type of dowels on fracture resistance of mandibular premolars. Materials and Methods: Fifty uniradicular mandibular premolars were divided into five groups (n = 10). Ten teeth received no treatment (group I). Samples in group II & III were decoronated 2 mm above cemento-enamel junction and received custom cast dowel-core and fiber dowel-composite core respectively, with 2 mm ferrule. Samples in group IV & V were decoronated at CEJ and were restored using cast dowels and fiber dowel-composite cores, without any ferrule. The restored teeth received metal ceramic crowns and were mechanically loaded. The specimens were subjected to a static load, until fracture, to determine the fracture resistance and fracture mode. Results: The samples with 2 mm ferrule had a higher fracture resistance than non ferrule groups. Within non ferrule groups, there were no significant differences in the fracture resistance. Specimen restored with cast dowel had more incidence of non-repairable fracture. Conclusions: Presence of ferrule increased the fracture resistance of endodontically treated teeth. In case of absence of ferrule, fiber dowels had similar fracture resistance as that of cast dowels and showed increased incidence of repairable fracture. PMID:24778519

  17. A Study of Inflammatory/Necrosis Biomarkers in the Fracture of the Femur Treated with Proximal Femoral Nail Antirotation

    PubMed Central

    Marino, Mariapaola; Palmieri, Giuseppe; Peruzzi, Marco; Scuderi, Flavia; Bartoccioni, Emanuela

    2015-01-01

    Pertrochanteric fractures are common injuries in adults and source of morbidity and mortality among the elderly. Different surgical techniques were recommended for their treatment but undoubtedly they add an additional inflammatory trauma along the fracture itself. Many attempts to quantify the degree of approach-related trauma are carried out through measurements of systemic inflammatory parameters. In this study we prospectively analyzed laboratory data of 20 patients over eighty with pertrochanteric fracture of the femur treated with proximal femoral nail antirotation (PFNA). This is an excellent device for osteosynthesis because it can be easily and quickly inserted by a mini-incision providing stable fixation and early full mobilization. Serum tumor necrosis factor-alpha (TNF-α), interleukin-6 (IL-6), C-reactive protein (CRP), and plasma creatin kinase (CK) were evaluated 1 hour preoperatively and 24 hours postoperatively. Our results show that PFNA did not induce significant increments in serum levels of inflammatory cytokines TNF-α and IL-6; CRP was elevated preoperatively in correlation with waiting time for surgery; CRP and CK showed a significant increment in the first postoperatory day; CK increment was correlated with surgical time length. We conclude that, for the markers we analyzed, PFNA shows a low biomechanical-inflammatory profile that represents an advantage over other techniques. PMID:26074676

  18. Effect of sealers on fracture resistance of endodontically treated teeth with and without smear layer removal: An in vitro study

    PubMed Central

    Jhamb, Swaty; Nikhil, Vineeta; Singh, Vijay

    2009-01-01

    Aim: The present study involved the in vitro comparison of root reinforcing abilities of two sealers, i.e., Ketac-Endo and Acroseal, in endodontically treated teeth in the presence and absence of smear layer. Materials and Methods: Fifty teeth were taken and sectioned at the cementoenamel junction. The teeth with faults were discarded and a total of 36 teeth were used for study. The samples were biomechanically prepared using step-back technique. In 10 teeth, the smear layer was preserved using sodium hypochlorite. Smear layers were removed from 10 teeth using 17% EDTA, and in another 10 samples, the smear layers were eliminated using 17% EGTA. The remaining samples served as controls. Samples were obturated with sealers using the lateral condensation technique. Ketac-Endo (3M) is a glass ionomer based root canal sealer, and Acroseal (Septodont) sealers were used. The teeth were then tested by using an Instron testing machine. Results: Ketac-Endo shows higher fracture resistance values in comparison to Acroseal. Other factors as the amount of tooth structure remaining, the agents used for the removal of smear layer and instrumentation techniques may alter the tooth resistance to fracture. Conclusion: Ketac-Endo shows higher fracture resistance values in comparison to Acroseal. PMID:20543918

  19. Grade 3 open tibial shaft fractures treated with a circular frame, functional outcome and systematic review of literature.

    PubMed

    Dickson, D R; Moulder, E; Hadland, Y; Giannoudis, P V; Sharma, H K

    2015-04-01

    We report on the surgical and functional outcome of 22 patients with Grade 3 open tibial fractures treated with circular frame. All cases united and there were no re-fractures or amputations. All patients were assessed at a minimum of 1-year post frame removal. Assessment included clinical examination, IOWA ankle and knee scores, Olerud and Molander ankle score and EuroQol EQ-5D. Clinical scores were either good or excellent in over half of the patients in all knee and ankle scores. There was a significant positive correlation between functional outcomes and the EQ-5D score. The EQ-5D mean health state visual analogue score was comparable to the general UK population despite patients scoring less than the average UK population in three of the five domains. 36% reported some difficulties in walking and 41% had problems with pain. 14% had difficulties with self-care and 46% had difficulties with their usual activities. 14% had problems with anxiety or depression. Systematic review of the literature suggests, in the management of open tibial fractures, circular frames provide equivalent or superior surgical outcomes in comparison with other techniques. Our study finds the application of a circular frame also results in a good functional outcome in the majority of cases. PMID:25648287

  20. Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation

    PubMed Central

    Dabis, John; Abdul-Jabar, Hani B.; Dabis, Hosam

    2015-01-01

    Dynamic hip screw fixation is a common orthopaedic procedure and to date, still can cause difficulties to the senior trauma surgeon. We present a case where an extra-capsular fracture of the proximal femur was managed with a dynamic hip screw (DHS) fixation. She proceeded to the operating theatre, where the fracture was stabilized with a 75-mm DHS and short-barrelled plate. The implant position was checked with intraoperative screening and the position accepted. Following attempted mobilization at 11 days post-operatively, the patient developed a recurrence of her preoperative pain. X-ray showed that the implant screw had separated from the barrel. Later scrutiny of the intraoperative screening films revealed that the barrel and screw were not engaged at the time of surgery. Intraoperative screening films should be carefully checked to ensure congruity of implant components. PMID:26136561

  1. Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation.

    PubMed

    Dabis, John; Abdul-Jabar, Hani B; Dabis, Hosam

    2015-01-01

    Dynamic hip screw fixation is a common orthopaedic procedure and to date, still can cause difficulties to the senior trauma surgeon. We present a case where an extra-capsular fracture of the proximal femur was managed with a dynamic hip screw (DHS) fixation. She proceeded to the operating theatre, where the fracture was stabilized with a 75-mm DHS and short-barrelled plate. The implant position was checked with intraoperative screening and the position accepted. Following attempted mobilization at 11 days post-operatively, the patient developed a recurrence of her preoperative pain. X-ray showed that the implant screw had separated from the barrel. Later scrutiny of the intraoperative screening films revealed that the barrel and screw were not engaged at the time of surgery. Intraoperative screening films should be carefully checked to ensure congruity of implant components. PMID:26136561

  2. Fat Embolism Syndrome in Fracture Tibia Treated By Unreamed Interlocking Nail

    PubMed Central

    Pal, Chandra Prakash; Kumar, Harish; Dinkar, Karuna Shankar; Agrawal, Alok

    2013-01-01

    Incidence of Fat embolism syndrome (FES) in fractures is about 16.3 but sometimes it is as high as 50% to 62%. The fat embolism is common in fatty bed ridden patients and in whom reamed interlocking is performed under tourniquet with prolonged injury-surgery interval. However in the case discussed here FES occurred under the exact opposite circumstances. In this 23 year lean and thin female with closed tibia fracture unreamed interlocking was performed without tourniquet & the operative procedure was done within 4 hours after trauma. Her pre-operative investigation were within normal limit. We want to discuss by this case report to highlight that even when risk factors are absent outlier events of FES can occur in any case and symptoms should not be discounted

  3. Management and Followup of Complicated Crown Fractures in Young Patients Treated with Partial Pulpotomy

    PubMed Central

    Ojeda-Gutierrez, Francisco; Martinez-Marquez, Brenda; Arteaga-Larios, Soraya; Ruiz-Rodriguez, M. Socorro; Pozos-Guillen, Amaury

    2013-01-01

    Two cases of young patients with traumatized permanent teeth having complicated crown fractures are reported. Endodontic management included partial pulpotomy by the Cvek technique; restorative management included resin restoration and reattachment of the teeth fragments. Treatments were considered successful in all cases according to the following criteria: absence of clinical symptoms, absence of X-ray signs of pathology, and presence of pulpal vitality 6 to 25 months after treatment. PMID:23864963

  4. Greater Trochanter Reconstruction in Unstabl Intertrochanteric Fractures Treated With Cemented Bipolar Hemiarthroplasty: A Technical Note

    PubMed Central

    Subramanian, G V; Guravareddy, A V; Reddy, Anil Kumar K R; Chiranjeevi, T

    2012-01-01

    Cemented Bipolar arthroplasty is an established method for treatment of comminuted Intertrochanteric fractures. Reconstruction of greater trochanter is an essential technical step to avoid complications like abductor lurch gait. We here describe a technique of reconstruction and fixation of greater trochanter using cancellous screws with wide washers made of reconstruction plate and tension band wiring. This gives a stable fixation of greater trochanter and avoids cut out, slippage of implants.

  5. Greater Trochanter Reconstruction in Unstabl Intertrochanteric Fractures Treated With Cemented Bipolar Hemiarthroplasty: A Technical Note.

    PubMed

    Subramanian, G V; Guravareddy, A V; Reddy, Anil Kumar K R; Chiranjeevi, T

    2012-01-01

    Cemented Bipolar arthroplasty is an established method for treatment of comminuted Intertrochanteric fractures. Reconstruction of greater trochanter is an essential technical step to avoid complications like abductor lurch gait. We here describe a technique of reconstruction and fixation of greater trochanter using cancellous screws with wide washers made of reconstruction plate and tension band wiring. This gives a stable fixation of greater trochanter and avoids cut out, slippage of implants. PMID:27298870

  6. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan.

    PubMed

    Hassan, Bassam; Metska, Maria Elissavet; Ozok, Ahmet Rifat; van der Stelt, Paul; Wesselink, Paul Rudolf

    2009-05-01

    Our aim was to compare the accuracy of cone beam computed tomography (CBCT) scans and periapical radiographs (PRs) in detecting vertical root fractures (VRFs) and to assess the influence of root canal filling (RCF) on fracture visibility. Eighty teeth were endodontically prepared and divided into four groups. The teeth in groups A and B were artificially fractured, and teeth in groups C and D were not. Groups A and C were root filled. Four observers evaluated the CBCT scans and PR images. Sensitivity and specificity for VRF detection of CBCT were 79.4% and 92.5% and for PR were 37.1% and 95%, respectively. The specificity of CBCT was reduced (p = 0.032) by the presence of RCF, but its overall accuracy was not influenced (p = 0.654). Both the sensitivity (p = 0.006) and overall accuracy (p = 0.008) of PRs were reduced by the presence of RCF. The results showed an overall higher accuracy for CBCT (0.86) scans than PRs (0.66) for detecting VRF. PMID:19410091

  7. Unusual Bilateral Rim Fracture in Femoroacetabular Impingement

    PubMed Central

    Rafols, Claudio; Monckeberg, Juan Edo; Numair, Jorge

    2015-01-01

    This is a report of one case of bilateral acetabular rim fracture in association with femoroacetabular impingement (FAI), which was treated with a hip arthroscopic procedure, performing a partial resection, a labral reinsertion, and a subsequential internal fixation with cannulated screws. Up to date, there are in the literature only two reports of rim fracture and “os acetabuli” in association with FAI. In the case we present, the pincer and cam resection were performed without complications; the technique used was published previously. With this technique the head of the screw lays hidden by the reattached labrum. We removed partially the fractured rim fragment and the internal fixation of the remaining portion was achieved with a screw. In the event of a complete resection of the fragment, it would have ended with a LCE angle of 18° and a high probability of hip instability. We believe that this bilateral case helps establish the efficacy and reproducibility of the technique described by Larson. PMID:25722907

  8. In Hospital and 3-Month Mortality and Functional Recovery Rate in Patients Treated for Hip Fracture by a Multidisciplinary Team

    PubMed Central

    Rostagno, Carlo; Buzzi, Roberto; Campanacci, Domenico; Boccacini, Alberto; Cartei, Alessandro; Virgili, Gianni; Belardinelli, Andrea; Matarrese, Daniela; Ungar, Andrea; Rafanelli, Martina; Gusinu, Roberto; Marchionni, Niccolò

    2016-01-01

    Objectives Medical comorbidities affect outcome in elderly patients with hip fracture. This study was designed to preliminarily evaluate the usefulness of a hip-fracture unit led by an internal medicine specialist. Methods In-hospital and 3-month outcomes in patients with hip fracture were prospectively evaluated in 121 consecutive patients assessed before and followed after surgery by a multidisciplinary team led by internal medicine specialist; 337 consecutive patients were recalled from ICD-9 discharge records and considered for comparison regarding in-hospital mortality. Results In the intervention period, patients treated within 48 hours were 54% vs. 26% in the historical cohort (P<0.0001). In-hospital mortality remained stable at about 2.3 per 1000 person-days. At 3 months, 10.3% of discharged patients had died, though less than 8% of patients developed postoperative complications (mainly pneumonia and respiratory failure). The presence of more than 2 major comorbidities and the loss of 3 or more BADL were independent predictors of death. 50/105 patients recovered previous functional capacity, but no independent predictor of functional recovery could be identified. Mean length of hospital stay significantly decreased in comparison to the historical cohort (13.6± 4.7 vs 17 ± 5 days, p = 0.0001). Combined end-point of mortality and length of hospitalization < 12 days was significantly lower in study period (27 vs 34%, p <0.0132). Conclusions Identification and stabilization of concomitant clinical problems by internal medicine specialists may safely decrease time to surgery in frail subjects with hip fracture. Moreover, integrated perioperative clinical management may shorten hospital stay with no apparent increase in in-hospital mortality and ultimately improve the outcome. These results are to be confirmed by a larger study presently ongoing at our institution. PMID:27389193

  9. Bridging Suture Repair for Acetabular Chondral Carpet Delamination

    PubMed Central

    Kaya, Mitsunori; Hirose, Toshiaki; Yamashita, Toshihiko

    2015-01-01

    Acetabular chondral carpet delamination is a frequent finding at hip arthroscopy. The cartilage is macroscopically normal but deboned from the subchondral bone, without a disruption at the chondrolabral junction. Arthroscopic anatomic repair of delaminated cartilage is challenging. We propose that a combination of microfracture and use of stitches to press the delaminated cartilage against the subchondral bone using a suture limb offers an effective method to provide an environment for cartilage repair. This article describes the technique of bridging suture repair for carpet delamination in detail; the technique enables the surgeon to stabilize the delaminated acetabular cartilage. Intra-articular soft anchors and an acetabular rim knotless anchor footprint provide a stable repair for delaminated cartilage. This technique is especially helpful in cases with acetabular cartilage carpet delamination. PMID:26759774

  10. Bone fractures among postmenopausal patients with endocrine-responsive early breast cancer treated with 5 years of letrozole or tamoxifen in the BIG 1-98 trial

    PubMed Central

    Rabaglio, M.; Sun, Z.; Castiglione-Gertsch, M.; Hawle, H.; Thürlimann, B.; Mouridsen, H.; Campone, M.; Forbes, J. F.; Paridaens, R. J.; Colleoni, M.; Pienkowski, T.; Nogaret, J.-M.; Láng, I.; Smith, I.; Gelber, R. D.; Goldhirsch, A.; Coates, A. S.

    2009-01-01

    Background: To compare the incidence and timing of bone fractures in postmenopausal women treated with 5 years of adjuvant tamoxifen or letrozole for endocrine-responsive early breast cancer in the Breast International Group (BIG) 1-98 trial. Methods: We evaluated 4895 patients allocated to 5 years of letrozole or tamoxifen in the BIG 1-98 trial who received at least some study medication (median follow-up 60.3 months). Bone fracture information (grade, cause, site) was collected every 6 months during trial treatment. Results: The incidence of bone fractures was higher among patients treated with letrozole [228 of 2448 women (9.3%)] versus tamoxifen [160 of 2447 women (6.5%)]. The wrist was the most common site of fracture in both treatment groups. Statistically significant risk factors for bone fractures during treatment included age, smoking history, osteoporosis at baseline, previous bone fracture, and previous hormone replacement therapy. Conclusions: Consistent with other trials comparing aromatase inhibitors to tamoxifen, letrozole was associated with an increase in bone fractures. Benefits of superior disease control associated with letrozole and lower incidence of fracture with tamoxifen should be considered with the risk profile for individual patients. PMID:19474112

  11. Total hip arthroplasty after rotational acetabular osteotomy.

    PubMed

    Ito, Hideya; Takatori, Yoshio; Moro, Toru; Oshima, Hirofumi; Oka, Hiroyuki; Tanaka, Sakae

    2015-03-01

    In this study, we aimed to determine whether the outcomes of total hip arthroplasty (THA) after rotational acetabular osteotomy (RAO) are equal to those of primary THA, and to elucidate the characteristics of THA after RAO. The clinical and radiographic findings of THA after RAO (44 hips), with minimum 24 months of follow-up, were compared with a matched control group of 58 hips without prior RAO. We found that the outcomes in terms of functional scores and complication rates did not differ between THA after RAO and THA without previous pelvic osteotomy, indicating that the results of THA after RAO are equivalent to those of primary THA. Although THA after RAO requires technical considerations, similar clinical outcomes to primary THA can be expected. PMID:25456635

  12. Primary stability of two uncemented acetabular components of different geometry: hemispherical or peripherally enhanced?

    PubMed Central

    Antoniades, G.; Smith, E. J.; Deakin, A. H.; Wearing, S. C.; Sarungi, M.

    2013-01-01

    Objective This study compared the primary stability of two commercially available acetabular components from the same manufacturer, which differ only in geometry; a hemispherical and a peripherally enhanced design (peripheral self-locking (PSL)). The objective was to determine whether altered geometry resulted in better primary stability. Methods Acetabular components were seated with 0.8 mm to 2 mm interference fits in reamed polyethylene bone substrate of two different densities (0.22 g/cm3 and 0.45 g/cm3). The primary stability of each component design was investigated by measuring the peak failure load during uniaxial pull-out and tangential lever-out tests. Results There was no statistically significant difference in seating force (p = 0.104) or primary stability (pull-out p = 0.171, lever-out p = 0.087) of the two components in the low-density substrate. Similarly, in the high-density substrate, there was no statistically significant difference in the peak pull-out force (p = 0.154) or lever-out moment (p = 0.574) between the designs. However, the PSL component required a significantly higher seating force than the hemispherical cup in the high-density bone analogue (p = 0.006). Conclusions Higher seating forces associated with the PSL design may result in inadequate seating and increased risk of component malpositioning or acetabular fracture in the intra-operative setting in high-density bone stock. Our results, if translated clinically, suggest that a purely hemispherical geometry may have an advantage over a peripherally enhanced geometry in high density bone stock. Cite this article: Bone Joint Res 2013;2:264–9. PMID:24326398

  13. Wear of highly crosslinked polyethylene acetabular components

    PubMed Central

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Munn, Zachary; Howie, Donald W

    2015-01-01

    Background and purpose Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). Methods A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). Results 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2–10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. Interpretation This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear. PMID:25301435

  14. Residual stress and damage-induced critical fracture on CO2 laser treated fused silica

    SciTech Connect

    Matthews, M; Stolken, J; Vignes, R; Norton, M

    2009-11-02

    Localized damage repair and polishing of silica-based optics using mid- and far-IR CO{sub 2} lasers has been shown to be an effective method for increasing optical damage threshold in the UV. However, it is known that CO{sub 2} laser heating of silicate surfaces can lead to a level of residual stress capable of causing critical fracture either during or after laser treatment. Sufficient control of the surface temperature as a function of time and position is therefore required to limit this residual stress to an acceptable level to avoid critical fracture. In this work they present the results of 351 nm, 3 ns Gaussian damage growth experiments within regions of varying residual stress caused by prior CO{sub 2} laser exposures. Thermally stressed regions were non-destructively characterized using polarimetry and confocal Raman microscopy to measure the stress induced birefringence and fictive temperature respectively. For 1 {approx} 40s square pulse CO{sub 2} laser exposures created over 0.5-1.25 kW/cm{sup 2} with a 1-3 mm 1/e{sup 2} diameter beam (T{sub max} {approx} 1500-3000 K), the critical damage site size leading to fracture increases weakly with peak temperature, but shows a stronger dependence on cooling rate, as predicted by finite element hydrodynamics simulations. Confocal micro-Raman was used to probe structural changes to the glass over different thermal histories and indicated a maximum fictive temperature of 1900K for T{sub max} {ge} 2000 K. The effect of cooling rate on fictive temperature caused by CO{sub 2} laser heating are consistent with finite element calculations based on a Tool-Narayanaswamy relaxation model.

  15. Clinical profile of delirium in patients treated for femoral neck fractures.

    PubMed

    Edlund, A; Lundström, M; Lundström, G; Hedqvist, B; Gustafson, Y

    1999-01-01

    The incidence of delirium, its predisposing factors, clinical profile, associated symptoms and consequences were investigated in 54 consecutive patients, 19 men and 35 women, mean age 77.1 years, admitted to an 'ortho-geriatric unit' with femoral neck fractures. The incidence of postoperative delirium was 15/54 (27.8%) and a logistic regression model found that dementia and a prolonged waiting time for the operation increased the risk of postoperative delirium. Delirium during the night was most common but in 5 patients the delirium was worst in the morning. Patients with delirium suffered more anxiety, depressed mood, emotionalism, delusions and hallucinations. A larger proportion of patients with delirium could not return to their previous dwelling, and a larger proportion of delirious patients were either dead, wheelchair-bound or bedridden at the 6-month follow-up (p < 0.005). The conclusion is that delirium is common and has a serious impact on the outcome after hip fracture surgery. PMID:10473932

  16. An In Vitro Study on the Effects of Post-Core Design and Ferrule on the Fracture Resistance of Endodontically Treated Maxillary Central Incisors

    PubMed Central

    Sreedevi, S; Sanjeev, R; Raghavan, Rekha; Abraham, Anna; Rajamani, T; Govind, Girish Kumar

    2015-01-01

    Background: Endodontically treated teeth have significantly different physical and mechanical properties compared to vital teeth and are more prone to fracture. The study aims to compare the fracture resistance of endodontically treated teeth with and without post reinforcement, custom cast post-core and prefabricated post with glass ionomer core and to evaluate the ferrule effect on endodontically treated teeth restored with custom cast post-core. Materials and Methods: A total of 40 human maxillary central incisors with similar dimensions devoid of any root caries, restorations, previous endodontic treatment or cracks were selected from a collection of stored extracted teeth. An initial silicone index of each tooth was made. They were treated endodontically and divided into four groups of ten specimens each. Their apical seal was maintained with 4 mm of gutta-percha. Root canal preparation was done and then post core fabrication was done. The prepared specimens were subjected to load testing using a computer coordinated UTM. The fracture load results were then statistically analyzed. One-way ANOVA was followed by paired t-test. Results: 1. Reinforcement of endodontically treated maxillary central incisors with post and core, improved their fracture resistance to be at par with that of endodontically treated maxillary central incisor, with natural crown. 2. The fracture resistance of endodontically treated maxillary central incisors is significantly increased when restored with custom cast post-core and 2 mm ferrule. Conclusion: With 2 mm ferrule, teeth restored with custom cast post-core had a significantly higher fracture resistance than teeth restored with custom cast post-core or prefabricated post and glass ionomer core without ferrule. PMID:26464537

  17. Computed modeling of humeral mid-shaft fracture treated by bundle nailing.

    PubMed

    Obruba, Petr; Capek, Lukas; Henys, Petr; Kopp, Lubomir

    2016-10-01

    Elastic bundle nailing is a method for simple humeral mid-shaft fracture osteosynthesis. The aim of our subsequent numerical simulations was to find out torsional and bending stiffness of an elastic bundle nailed humerus. Parametrical 3D numerical model was developed. The diameter of nails was the varying parameter of 1.8, 2.5, 3 and 4 mm. From our results can be seen that the bending stiffness in bundle nailing technique does not depend on nail diameter. On the contrary the torsional stiffness does highly depend on nail diameter. The dependency of the maximal stress on a nail diameter during bending and torsion of the humerus is non-linear. It can be seen that the higher diameter is used the higher stress occurs. Achieved results allow us for the recommendation of optimal nail diameter for this method, which lies between 2 and 3 mm. PMID:26828368

  18. Olecranon Fractures.

    PubMed

    Brolin, Tyler J; Throckmorton, Thomas

    2015-11-01

    Olecranon fractures are common upper extremity injuries, with all but nondisplaced fractures treated surgically. There has been a recent shift in the surgical management of these fractures from tension band wiring to locking plate fixation and intramedullary nailing; however, this comes with increased implant cost. Although most patients can expect good outcomes after these various techniques, there is little information to guide a surgeon's treatment plan. This article reviews the epidemiology, classification, treatment, and outcomes of olecranon fractures. PMID:26498547

  19. Preliminary Biomechanical Study of Different Acetabular Reinforcement Devices for Acetabular Reconstruction

    PubMed Central

    Tai, Ching-Lung; Lee, Po-Yi; Hsieh, Pang-Hsing

    2015-01-01

    Background Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct. However, all commercially available ARDs are designed with non-locking fixation. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction. Methods Three types of ARDs were examined to evaluate the postoperative compression and angular stability: i) standard commercial ARDs, ii) standard ARDs modified with monoaxial and iii) standard ARDs modified with polyaxial locking screw mechanisms. All ARDs were implanted into osteomized synthetic pelvis with pelvic discontinuity. Axial compression and torsion tests were then performed using a servohydraulic material testing machine that measured load (angle) versus displacement (torque). Initial stability was compared among the groups. Results Equipping ARDs with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs. In both compression and torsion experiments, the monoaxial interlocking construct demonstrated the highest construct stiffness (672.6 ± 84.1 N/mm in compression and 13.3 ± 1.0 N·m/degree in torsion), whereas the non-locked construct had the lowest construct stiffness (381.4 ± 117.2 N/mm in compression and 6.9 ± 2.1 N·m/degree in torsion) (P < 0.05). Conclusions Our study demonstrates the potential benefit of adding a locking mechanism to an ARD. Polyaxial ARDs provide the surgeon with more flexibility in placing the screws at the cost of reduced mechanical performance. This in vitro study provides a preliminary evaluation of biomechanical performance for ARDs

  20. Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: a finite element study with biphasic acetabular cartilage properties.

    PubMed

    Li, Junyan; Hua, Xijin; Jin, Zhongmin; Fisher, John; Wilcox, Ruth K

    2014-11-01

    Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries. PMID:24957488

  1. Influence of clearance on the time-dependent performance of the hip following hemiarthroplasty: A finite element study with biphasic acetabular cartilage properties

    PubMed Central

    Li, Junyan; Hua, Xijin; Jin, Zhongmin; Fisher, John; Wilcox, Ruth K.

    2014-01-01

    Hip hemiarthroplasty is a common treatment for femoral neck fracture. However, the acetabular cartilage may degenerate after hemiarthroplasty leading to postoperative failure and the need for revision surgery. The clearance between the acetabular cartilage and head of the prosthesis is one of the potential reasons for this failure. In this study, the influence of joint clearance on the biomechanical function of a generic hip model in hemiarthroplasty was investigated using biphasic numerical simulation. Both a prolonged loading period of 4000 s and dynamic gait load of 10 cycles were considered. It was found that a larger clearance led to a higher stress level, a faster reduction in load supported by the fluid and a faster cartilage consolidation process. Additionally, the mechanical performance of the acetabular cartilage in the natural model was similar to that in the hemiarthroplasty model with no clearance but different from the hemiarthroplasty models with clearances of 0.5 mm and larger. The results demonstrated that a larger clearance in hip hemiarthroplasty is more harmful to the acetabular cartilage and prosthesis heads with more available dimensions (i.e. smaller increments in diameter) could be manufactured for surgeons to achieve a lower clearance, and reduced contact stress in hemiarthroplasty surgeries. PMID:24957488

  2. Fractures of the neck of the fifth metacarpal bone, treated by percutaneous intramedullary nailing: surgical technique, radiological and clinical results study (28 cases).

    PubMed

    Boussakri, Hassan; Elidrissi, Mohamad; Azarkane, Mohamad; Bensaad, Soufiane; Bachiri, Mohammed; Shimi, Mohamed; Elibrahimi, Abdelhalim; Elmrini, Abdelmajid

    2014-01-01

    This study report the results in 28 patients affected by closed fractures of the neck of the fifth metacarpal bone (boxer's fracture), treated with percutaneous elastic intramedullary nailing using a single wire, to verify the effectiveness of this surgical treatment. We reviewed the results of 28 patients treated with A single Kirschner wire (K-wire) pre-bent in a lazy-S fashion with a mild bend at approximately 5 millimeters, The K-wire is inserted blunt end first in an antegrade manner and the fracture reduced as the wire is passed across the fracture site The wire is usually removed with pliers post-operatively at four weeks in the fracture clinic. The follow-up period averaged of 20,75 months. The parameters evaluated included angulation, rotational alignment, postoperative metacarpophalangeal (MCP) range of motion, and time to union. We opted for this treatment in all cases, regardless volar angulation of the metacarpal head, malrotation of the fifth finger and associated or/no with a severe swelling of the hand. All the patients were reviewed clinically and radiologically at an average of 20,75 months after surgery. At the final follow-up, no patient reported residual pain and All fractures proceeded to bony union but we have one fracture had to be revised for failed fixation and three superficial wound infections needed antibiotic treatment. We recommend that this minimally invasive: percutaneous intramedullary nailing using a single k-wire in all metacarpal neck fracture (boxers' fractures), especially when severe swelling of the hand is present, with good functional results and low morbidity. PMID:25419314

  3. Open-configuration MRI study of femoro-acetabular impingement.

    PubMed

    Yamamura, Mitsuyoshi; Miki, Hidenobu; Nakamura, Nobuo; Murai, Masakazu; Yoshikawa, Hideki; Sugano, Nobuhiko

    2007-12-01

    Femoro-acetabular impingement has been proposed as a causative factor of primary hip osteoarthritis. However, primary osteoarthritis of the hip is infrequent in Japan and other Asian countries, even though the hips of Asians frequently sustain impingement, since the Asian lifestyle commonly requires a larger range of hip motion than the Western lifestyle. Therefore, using open-configuration MRI, we investigated whether impingement actually occurs during some traditional Japanese hip positions. The hips of 5 healthy Japanese females were examined in 5 sitting postures: 1) sitting straight; 2) bowing while sitting straight; 3) sitting cross-legged; 4) W-sitting; and 5) squatting. The impingement point was detected by multiple plane reconstructed (MPR) views along with the acetabular rim depicted circumferentially. Impingement was considered to have occurred when, on MRI, the anterior femoral head-neck junction approached the acetabular rim and the femoral head was seen to float from the bottom of the acetabulum with the acetabular rim acting as a fulcrum. Impingement was observed in all volunteers in the W-sitting position, and in 2 of 5 volunteers during squatting. These findings show that impingement occurs frequently during daily Japanese activities. Thus, depending on race, femoro-acetabular impingement might not always cause primary osteoarthritis of the hip. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1582-1588, 2007. PMID:17600811

  4. Accuracy of the modified Hardinge approach in acetabular positioning

    PubMed Central

    Goyal, Prateek; Lau, Adrian; McCalden, Richard; Teeter, Matthew G.; Howard, James L.; Lanting, Brent A.

    2016-01-01

    Background The surgical approach chosen for total hip arthroplasty (THA) may affect the positioning of the acetabular component. The purpose of this study was to examine the accuracy in orienting the acetabular component using the modified Hardinge approach. Methods We used our institutional arthroplasty database to identify patients with primary, press-fit, hemispherical acetabular components of a metal-on-polyethylene THA performed between 2003 and 2011. Patients with radiographs obtained 1–3 years after the index procedure were included for measurement of anteversion and inclination angles. Acceptable values of anteversion and abduction angles were defined as 15° ± 10° and 40° ± 10°, respectively. Results We identified 1241 patients from the database, and the modified Hardinge approach was used in 1010 of the patients included in our analysis. The acetabular component was anteverted in the acceptable zone in 54.1% of patients. The abduction angle was within the defined range in 79.2% of patients. Combined anteversion and abduction angles within the defined zone were present in 43.6% of patients. Conclusion Consistent with studies examining accuracy from other approaches, our study reveals that the modified Hardinge approach was only moderately accurate in positioning the acetabular component in the acceptable zone. PMID:27240130

  5. [Retrospective analysis of consecutively treated distal radius fractures with the external fixator].

    PubMed

    Melik, N; Togninalli, D; Biegger, P

    1994-12-01

    The purpose of this study was to determine retrospectively some subjective and objective parameters following the operative treatment of 32 patients with "complex" (intraarticular and/or comminuted) fractures of the distal radius using the small AO external fixation device. The mean follow-up period was 20 months (minimum 4, maximum 48) and the mean age of the subjects was 62 years (minimum 27, maximum 91). Subjective results such as "general feeling", mobility, strength and pain, expressed with a scoring system (% of maximum obtainable points), showed an overall good result and ranged between 71% (pain), 81% (strength) and 91% (mobility and "general feeling"). Regarding the objective results, no major skin or soft tissue distress (Sudeck dystrophy) was noted. However, there was a general tendency towards a mobility deficit of the wrist operated on, which was statistically significant (P < 0.01) for flexion, extension, supination and abduction (respectively, -17.7%, -12.4%, -7.1% and -12.5%). The late standard radiological and lateral controls showed a mean radial angle of +2.13 degrees (B or lateral radial angle) and +23.13 degrees (A or AP angle), respectively. The analysis of data, as expressed by time after operation (< or > than 10 months), showed no relevant difference between the two groups (age of both similar), as expressed by age (< or > than 60 years); the data only showed differences in strength and pain (scores by 92% vs 82% for force and 92% vs 76% for pain) and in flexion and extension (-22.8% and -14%, P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7855610

  6. Polyethylene wear in uncemented acetabular components.

    PubMed

    Hernandez, J R; Keating, E M; Faris, P M; Meding, J B; Ritter, M A

    1994-03-01

    We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated with uncemented femoral components (0.22 mm/year) was significantly higher than the wear rate (0.15 mm/year) of cups articulated within cemented femoral components (p < 0.05). These results can be compared with previously reported wear rates of 0.08 mm/year for cemented all-polyethylene cups and 0.11 mm/year for cemented metal-backed cups. The higher wear rates of uncemented arthroplasties could jeopardize the long-term results of this type of hip replacement. PMID:8113288

  7. Computer-Assisted Rotational Acetabular Osteotomy for Patients with Acetabular Dysplasia

    PubMed Central

    Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-01-01

    Rotational acetabular osteotomy (RAO) is a well-established surgical procedure for patients with acetabular dysplasia, and excellent long-term results have been reported. However, RAO is technically demanding and precise execution of this procedure requires experience with this surgery. The usefulness of computer navigation in RAO includes its ability to perform three-dimensional (3D) preoperative planning, enable safe osteotomy even with a poor visual field, reduce exposure to radiation from intraoperative fluoroscopy, and display the tip position of the chisel in real time, which is educationally useful as it allows staff other than the operator to follow the progress of the surgery. In our results comparing 23 hips that underwent RAO with navigation and 23 hips operated on without navigation, no significant difference in radiological assessment was observed. However, no perioperative complications were observed in the navigation group whereas one case of transient femoral nerve palsy was observed in non-navigation group. A more accurate and safer RAO can be performed using 3D preoperative planning and intraoperative assistance with a computed tomography-based navigation system. PMID:26929806

  8. Osteonecrosis of the Femoral Head in the Setting of a Complex Acetabulum Fracture without Hip Dislocation Treated Surgically Using Ilio-inguinal Approach: A Case Report

    PubMed Central

    Sobti, Anshul Shyam

    2014-01-01

    Osteonecrosis in isolated fractures of the acetabulum without dislocation of hip seems to be a known complication, but to our knowledge it has not been reported adequately. The causative nature of post-traumatic femoral head osteonecrosis has not been studied critically. The pathophysiology of osteonecrosis in this case also eludes us. Striking evidence points towards the intra-operative blood loss and low mean arterial pressure possibly leading to hypo-perfusion of femoral head leading to osteonecrosis. Fractures of the acetabulum pose a difficult problem for the patient and the surgeon because of possible complications. Thus any surgeon involved in surgery for fractures of the acetabulum should be aware of the possibility of this potential complication. Here is a 61-year male, who sustained a complex fracture of the acetabulum without hip dislocation, subsequently was treated surgically with internal fixation using an anterior approach, 10 months after surgery patient developed osteonecrosis of the femoral head.

  9. Surface-enhanced Raman scattering study of the healing of radial fractures treated with or without Huo-Xue-Hua-Yu decoction therapy

    NASA Astrophysics Data System (ADS)

    Chen, Weiwei; Huang, Hao; Chen, Rong; Feng, Shangyuan; Yu, Yun; Lin, Duo; Lin, Jia

    2014-11-01

    This study aimed to assess, through surface-enhanced Raman scattering (SERS) spectroscopy, the incorporation of calcium hydroxyapatite (CHA ~960 cm-1) and other biochemical substances in the repair of complete radial fractures in rabbits treated with or without Huo-Xue-Hua-Yu decoction (HXHYD) therapy. A total of 18 rabbits with complete radial fractures were randomly divided into two groups; one group was treated with HXHYD therapy and the other without therapy acted as a control. The animals were sacrificed at 15, 30 and 45 d after surgery. Specimens were routinely prepared for SERS measurement and high quality SERS spectra from a mixture of bone tissues and silver nanoparticles were obtained. The mineral-to-matrix ratios from the control and treated groups were calculated. Results showed that both deposition content of CHA measured by SERS spectroscopy and the mineral-to-matrix ratio in the treated group were always greater than those of the control group during the experiment, demonstrating that HXHYD therapy is effective in improving fracture healing and that SERS spectroscopy might be a novel tool to assess fracture healing.

  10. Comparative evaluation of fracture resistance of glass fiber reinforced, carbon, and quartz post in endodontically treated teeth: An in-vitro study

    PubMed Central

    Sharma, Shweta; Attokaran, George; Singh, Kunwar S.; Jerry, Jeethu J.; Ahmed, Naima; Mitra, Nirban

    2016-01-01

    Aim and Objectives: Use of posts improves the physical properties of endodontically-treated teeth. Different post types are developed such as metal, custom-made, carbon, and quartz. The present study was conducted to evaluate the fracture resistance of glass fiber-reinforced, carbon, and quartz post in endodontically-treated teeth. Materials and Methods: Forty extracted human maxillary incisor teeth were decoronated and endodontically treated and equally divided into 4 groups; control, glass fiber-reinforced, carbon, and quartz posts. No post was used in the control group. Post space was prepared and cemented with different posts and subjected to universal testing machine to check fracture resistance. The data were statistically analyzed using t-test and analysis of variance to compare the mean difference between groups (SPSS version 20, IBM). Results: Quartz type of endodontic post showed good fracture resistance compared to carbon and resin-reinforced post. Least resistance was observed in the control group without post. Conclusion: Quartz, carbon, and glass fiber-reinforced posts show good resistance to fracture, and hence can be used in endodontically-treated teeth to enhance their strength. PMID:27583227

  11. The effect of marginal ridge thickness on the fracture resistance of endodontically-treated, composite restored maxillary premolars.

    PubMed

    Shahrbaf, Shahrbaf; Mirzakouchaki, Behnam; Oskoui, Siavash Savadi; Kahnamoui, Mehdi Abed

    2007-01-01

    This study evaluated the effect of varying thicknesses of marginal ridge on the fracture resistance of endodontically-treated maxillary premolars restored with composite. Ninety non-carious maxillary premolars, extracted for orthodontic reasons, were selected for this experimental in vitro study. The teeth were randomly assigned to six groups (n=15). Group 1 received no preparation. In groups 2 through 6, the premolars were root filled and DO preparations were created, while MOD preparations were also created for group 2. The condition of the boxes was: the gingival seat was 1.5 mm above the CEJ and the buccolingual dimensions were 3.5 mm in gingival and 3 mm in occlusal. In groups 3 through 6, the dimensions of the mesial marginal ridge were measured using a digital caliper as follows: 2 mm, 1.5 mm, 1 mm and 0.5 mm, respectively. All samples in groups 2 through 6 were restored with a dentin bonding system (DBS: Single Bond, 3M) and resin composite (Z 250, 3M). Subsequently, premolars from all six groups were subjected to a thermocycling regimen of 500 cycles between 5 degrees C and 55oC water baths. Dwell time was 30 seconds, with a 10-second transfer time between baths. The premolars were submitted to axial compression up to failure at a 45 degrees angle to the palatal cusp in Universal Test Equipment (Tinius Olsen, Ltd, H5K-S model). The mean load necessary to fracture the samples was recorded in newtons (N), and data were subjected to analysis of variance (ANOVA) and LSD post-hoc test. According to these results, the mean loads necessary to fracture the samples in each group were (in N): group 1: 732 +/- 239, group 2:489 +/- 149, group 3: 723 +/- 147, group 4: 696 +/- 118, group 5: 654 +/- 183 and group 6: 506 +/- 192). Differences between group 1 and groups 2 and 6, and also differences between groups 3, 4 and 5 compared with group 2 and 6 were statistically significant (p < 0.05). PMID:17555181

  12. Acetabular Labral Tears in Patients with Sports Injury

    PubMed Central

    Kang, Chan; Cha, Soo-Min

    2009-01-01

    Background We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Methods Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. Results The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. Conclusions In

  13. Effect of acetabular reinforcement ring with hook for acetabular dysplasia clarified by three-dimensional finite element analysis.

    PubMed

    Zhao, Xin; Chosa, Etsuo; Yamako, Go; Watanabe, Shinji; Deng, Gang; Totoribe, Koji

    2013-12-01

    The objective of this study was to biomechanically determine the effect of the severity of acetabular dysplasia, number and positions of screws and type of bone graft material used on the initial fixation strength of the acetabular reinforcement ring with hook (Ganz ring) using the finite element method. Relative micromotion increased as the severity of acetabular dysplasia increased and tended to decrease as the number of screws increased, but varied according to screw placement position. Increased strength of the bone graft material led to decreased relative micromotion. Biomechanically, the Ganz ring can be placed securely using 3 screws in patients with Crowe 1 dysplasia. However, in patients with Crowe 2 or higher dysplasia, it is necessary to spread at least 4 screws across an area of good host bone. PMID:23993349

  14. Evaluation of fracture resistance of endodontically treated teeth restored with composite resin along with fibre insertion in different positions in vitro.

    PubMed

    Rahman, Hena; Singh, Shailja; Chandra, Anil; Chandra, Ramesh; Tripathi, Supratim

    2016-08-01

    This study was carried out to compare the different techniques of placement of polyethylene fibre (Ribbond) on reinforcement of endodontically treated teeth with MOD cavities in vitro. Forty extracted human premolars were randomly assigned to four groups (n = 10). Teeth in Groups I-IV received root canal treatment and a MOD cavity preparation, with gingival cavosurface margin 1.5 mm in coronal to cementoenamel junction. Group I served as no fibre group, Group II as occlusal fibre group, Group III as base fibre group and Group IV as dual-fibre group (occlusal and base both). Subsequent to restoring with composite resin and thermocycling, a vertical compressive force was applied at a cross-head speed of 0.5 mm min(-1) using universal testing machine until fracture. Data were analysed using one-way analysis of variance and Tukey's post hoc tests. Fracture resistance was significantly highest in dual-fibre group (P < 0.001) as compared with other groups. The highest favourable fracture rate was observed in the base fibre group (70%). This study concluded that the use of polyethylene fibre inserted over or under the restoration significantly increased the fracture strength of the root canal-treated teeth and maximum fracture resistance was observed when cavity was restored using dual-fibre technique. PMID:26419210

  15. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    DOE PAGESBeta

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; et al

    2016-02-16

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibrilmore » deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. We find the significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.« less

  16. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    NASA Astrophysics Data System (ADS)

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; Tang, Simon; Amling, Michael; Ritchie, Robert O.; Busse, Björn

    2016-02-01

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibril deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. The significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.

  17. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    PubMed Central

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; Tang, Simon; Amling, Michael; Ritchie, Robert O.; Busse, Björn

    2016-01-01

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibril deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. The significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates. PMID:26879146

  18. Evaluation of Fracture Resistance of Endodontically Treated Teeth Filled with Gutta-Percha and Resilon Obturating Material: An In Vitro Study

    PubMed Central

    Khan, Sheeba; Inamdar, Mohammed Nasir K; Munaga, Swapna; Ali, Syed Akbar; Rawtiya, Manjusha; Ahmad, Ezaz

    2015-01-01

    Background: As per many studies endodontically treated teeth are widely considered to be more susceptible to fracture than vital teeth. Obturation strains and post placement have been a major cause of vertical root fracture. Present study was conducted to compare in vitro fracture resistance after filling with either Gutta-percha or Resilon by lateral condensation techniques in root canals. This study evaluated a new thermoplastic synthetic polymer based on polyester, which contains bioactive and radiopaque filler, Resilon performs every way as Gutta-percha except that it allows the bonding agent to attach to the resin core and the dentin wall thus forming a monoblock. Materials and Methods: In the present study 90 freshly extracted single-rooted human mandibular premolar teeth endodontically treated, were cut at the cemento-enamel junction, and were randomly divided into three groups of 30 each as teeth of Group A (Control) received no obturation, Group B teeth were obturated using Gutta-percha/AH26, and Group C teeth were obturated using Resilon/Epiphany obturating kit. Each specimen were mounted in acrylic in a polyvinyl ring and then tested for fracture resistance with the help of an universal testing machine. A compressive force was applied until the root is fractured. The data were subjected to analysis of variance for comparing mean difference of fracture resistance among three groups. Multiple comparisons among these groups were carried out by non-parametric Kruskal–Wallis analysis. A p value of <0.0001 was considered a statistically significant difference. Results: The results obtain after analysis showed no significant differences in the fracture resistance between the two tested groups of endodontic sealers. Conclusion: Within the limitation of the present in-vitro study, Resilon/Epiphany sealer performs better than Gutta-percha/AH 26 sealer with lateral condensation technique. PMID:26668476

  19. A Prospective Study on Radiological and Functional Outcome of Displaced Tongue Type Intra-Articular Calcaneal Fractures Treated by Percutaneous Screw Fixation

    PubMed Central

    Hegde, Anoop; Mathias, Lawrence John; Shetty, Vikram; Shetty, Ashwin

    2016-01-01

    Introduction Calcaneal fractures have posed a challenge to orthopaedic surgeon for many years. The major problem is to reconstruct the fracture and improve healing of the fracture and also the surrounding tissues. Anatomic restoration of the three-dimensional anatomy of the calcaneum is the goal of surgical management of calcaneal fractures. Over the years, various techniques have been developed to accomplish this goal. Aim To determine the functional outcome in displaced tongue-type calcaneal fracture treated by percutaneous screw fixation. Materials and Methods A prospective study was conducted from October 2012 and September 2014. A total of 23 patients with intra-articular ‘tongue type’ calcaneal fractures were included in the study. Complete clinical and radiological evaluation was done. The surgical procedure encompassed closed reduction and fixation with two criss-cross 6.5 mm cannulated cancellous across the fracture site under fluoroscopic guidance. Postoperatively, on day three ankle and toe mobilization was begun. Non-weight bearing crutch mobilization was begun on postoperative day three. Reviews were done at 6 weeks, 12 weeks and 24 weeks postoperatively. At 6 weeks partial weight bearing mobilization was started. Full weight bearing was begun at 12 weeks. The patient was finally reviewed at 24 weeks and assessment of ankle function was done as per the Maryland foot scoring system. Radiographs were compared and preoperative and postoperative Gissane’s and Bohler’s angles were also compared. The results were analysed as per descriptive statistics (frequency, percentage). The complications noted were documented. Results Of the 23 patients under the study, three had excellent results with mean score of 90, 17 had good results with mean score of 82.94 and three had fair results with mean score of 74. Only one patient had subtalar arthritis as a complication. No other complications were seen. Conclusion Percutaneous screw fixation of tongue type

  20. Fracture Rate, Quality of Life and Back Pain in Patients with Osteoporosis Treated with Teriparatide: 24-Month Results from the Extended Forsteo Observational Study (ExFOS).

    PubMed

    Langdahl, Bente L; Ljunggren, Östen; Benhamou, Claude-Laurent; Marin, Fernando; Kapetanos, George; Kocjan, Tomaz; Lespessailles, Eric; Napoli, Nicola; Nikolic, Tatjana; Petto, Helmut; Moll, Thomas; Lindh, Erik

    2016-09-01

    We describe the pre-planned interim analysis of fracture outcomes, health-related quality of life (HRQoL) and back pain in patients with severe osteoporosis treated with teriparatide for up to 24 months in the Extended Forsteo (Forsteo(®) is a registered trade name of Eli Lilly and Company) Observational Study (ExFOS), a prospective, multinational, observational study. Data on incident clinical fractures, HRQoL (EQ-5D questionnaire) and back pain [100 mm visual analogue scale (VAS)] were collected. The number of patients with fractures was summarised in 6-month intervals and fracture rate over each 6-month period was assessed using logistic regression for repeated measures. Changes from baseline in EQ-5D and back pain VAS were analysed using mixed models for repeated measures. Of 1454 patients in the active treatment cohort, 90.6 % were female and 14.4 % were taking glucocorticoids. During teriparatide treatment (median duration 23.7 months), 103 patients (7.1 %) sustained a total of 122 incident clinical fractures (21 % vertebral, 79 % non-vertebral). A 49 % decrease in the odds of fractures and a 75 % decrease in the odds of clinical vertebral fractures were observed in the >18- to 24-month period versus the first 6-month period (both p < 0.05). EQ-5D scores and back pain VAS scores were significantly improved from baseline at each post-baseline observation during teriparatide treatment. In conclusion, patients with severe osteoporosis showed a significant reduction in the incident fracture rate during 24 months of teriparatide treatment in routine clinical practice, accompanied by a significant improvement in HRQoL and reduction in back pain. Results should be interpreted in the context of the non-controlled design of this observational study. PMID:27137783

  1. Retrieved Highly Crosslinked UHMWPE Acetabular Liners Have Similar Wear Damage as Conventional UHMWPE

    PubMed Central

    Schroder, David T.; Kelly, Natalie H.; Parks, Michael L.

    2010-01-01

    Background Highly crosslinked UHMWPE is associated with increased wear resistance in hip simulator and clinical studies. Laboratory and case studies, however, have described rim fracture in crosslinked acetabular liners. Controversy exists, therefore, on the relative merits of crosslinked liners over conventional liners in terms of wear performance versus resistance to fatigue cracking. Questions/purposes We asked whether crosslinked liners would show less surface damage than conventional liners but would be more susceptible to fatigue damage. Methods We examined 36 conventional UHMWPE and 39 crosslinked UHMWPE retrieved implants with similar patient demographics and identical design for evidence of wear damage, including articular surface damage, impingement, screw-hole creep, and rim cracks. Results We observed no difference in wear damage scores for the two liners. Conventional liners more frequently impinged but were more often elevated with smaller head sizes. We observed creep in approximately 70% of both types of liners. Incipient rim cracks were found in five crosslinked liners, and one liner had a rim fracture. Only one conventional liner had an incipient rim crack. Conclusions Contrary to our expectation, damage was similar between crosslinked and conventional UHMWPE liners. Moreover, the 15% occurrence (six of 39) of incipient or complete fractures in crosslinked liners as compared with a 3% occurrence (one of 36) in conventional liners may have implications for the long-term performance of crosslinked liners. Longer-term studies will be necessary to establish the fate of rim cracks and thus the overall clinical fatigue performance of crosslinked liners. PMID:20844998

  2. [Fractures of the proximal end of the humerus treated by the Kapandji centro-medullary nailing technic. A review of 21 cases].

    PubMed

    Monin, S; van Innis, F

    1999-06-01

    Over a 7 years period (from September 1989 to April 1996), 25 patients have been treated for proximal humeral fractures using Kapandji's method of internal fixation. Twenty-one were available for evaluation. The mean follow-up was 3 years 9 months. Various indications were found, with a majority of 2 and 3-part fractures. Complications were frequent, the most common being pin migration, but the functional results following Constant scores are very good. The technique is easy, quick, non- invasive and inexpensive. The approach is direct and avoids opening the elbow joint. PMID:10427799

  3. Isolated trapdoor-type medial blowout fracture in an adult presenting horizontal diplopia treated by endoscopic endonasal approach.

    PubMed

    Noh, Woong Jae; Park, Tae Jung; Kim, Joo Yeon; Kwon, Jae Hwan

    2013-01-01

    Orbital blowout fracture frequently occurs along the floor or medial aspect of the orbital wall, which are the two thinnest areas of the bony orbit. True trapdoor injury of the orbit is less common and is rare as an isolated medial wall injury, because the medial orbital wall has several bony septa within the ethmoid sinus that provide support and decrease the risk of a trapdoor fracture. Additionally, the incidence of trapdoor-type blowout fracture in adults is lower than in children. In a trapdoor-type blowout fracture with restricted ocular movement, prompt diagnosis and early intervention are associated with better clinical outcomes. We encountered a case of trap door-type medial blowout fracture with horizontal eye ball movement limitation in an adult. She underwent endonasal endoscopic reduction surgery for the medial blowout fractures. Here we report this case, and suggest early diagnosis and prompt surgical exploration. PMID:24964421

  4. Dissociation of a polyethylene liner from an acetabular cup.

    PubMed

    Cameron, H U

    1993-10-01

    A polyethylene linear dissociated from a metal acetabular shell that could not be removed at the time of hip revision because the hexagonal hole in its screw head had become rounded off. A high-speed metal cutting burr was used to remove the screw and allow cup revision. PMID:8265224

  5. Cross table lateral radiography for measurement of acetabular cup version

    PubMed Central

    Gunderson, Ragnhild Beate

    2016-01-01

    Background Appropriate orientation of the acetabular cup is an important factor for long-term results of total hip arthroplasty. For measurement of cup version cross-table lateral radiography is frequently used, but the reliability has been questioned. We compared cross table lateral radiography with computed tomography in patients that had undergone primary total hip arthroplasty. Methods The study was prospectively done in 117 patients (117 hips). At 3 months after total hip replacement the acetabular version was measured by cross table lateral radiography and compared to measurements by computed tomography. Results By cross table lateral radiography acetabular anteversion was on mean 13.9° with a standard deviation of 10.1° as compared to 17.8°±12.6° by computed tomography. Mean difference was −3.8 with a distribution of measurements of ±13 degrees for 95% of the cases. Conclusions Our study shows that cross table radiography provides acceptable information for clinical use, but has limited use for precise analysis of acetabular cup version. PMID:27275482

  6. Tritanium acetabular wedge augments: short-term results

    PubMed Central

    Restrepo, Camilo; Heller, Snir

    2016-01-01

    Background Reconstruction of acetabular defects in total hip arthroplasty (THA) presents a great challenge to orthopaedic surgeons. Previous studies have reported on the use and outcomes of trabecular metal acetabular augments for the reconstruction of acetabular defects. However, no study has been conducted evaluating the short-term results of tritanium acetabular wedge augments for the reconstruction of acetabular defects in THA. Methods A retrospective study was conducted using a prospective database at a single institution including primary and revision THA patients from January 2013 to December 2014. Patients were included if they received a tritanium acetabular wedge augment system and had a minimum of 2-year follow-up (average 2.2 years ±0.3, range, 2–2.6 years). Demographic data and outcomes data [Harris Hip Score—HHS and Short Form (SF)-36] was collected. Radiographic data was also collected on THA revision cases (Paprosky classification), developmental dysplasia of the hip (DDH) cases (Crowe classification), and radiographic follow-up using DeLee and Charnley’s classification system. Results There were 4 revision THA patients, 3 DDH patients, and 1 patient with posttraumatic arthritis. At the latest radiographic follow-up, there were no lucent lines in DeLee and Charnley Zones I, II or III. During the follow-up period, there was no open revision surgery. The SF-36 physical score significantly improved from preoperative measurement (29.6±2.2) to postoperative measurement (52.2±8.7, P=0.003), and the SF-36 mental score also significantly improved from preoperative assessment (34.5±4.5) to postoperative assessment (52.2±7.5, P=0.003). Total HHS scores also significantly improved postoperatively (P=0.02), with significant improvements in both the pain score (P=0.01) and function score (P=0.02). Conclusions Tritanium acetabular wedge augments in this short follow-up case series exhibit high clinical outcome scores, no radiographic lucency, and no

  7. Validation of neck axis distance as a radiographic measure for acetabular anteversion

    PubMed Central

    Nitschke, Ashley; Petersen, Brian; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer

    2016-01-01

    Excessive acetabular anteversion is an important treatment consideration in hip preservation surgery. There is currently no reliable quantitative method for determining acetabular anteversion utilizing radiographs alone. The three main purposes of this study were to: (i) define and validate the neck axis distance (NAD) as a new visual and reproducible semi-quantitative radiographic parameter used to measure acetabular anteversion; (ii) determine the degree of correlation between NAD and computed tomography (CT)-measured acetabular anteversion; (iii) establish a sensitive and specific threshold value for NAD to identify excessive acetabular anteversion. This retrospective cohort study included all patients presenting to a single institution over a 14-month period who had undergone a dedicated musculoskeletal CT pelvis along with a standardized anteroposterior (AP) pelvis radiograph. Trained observers measured the NAD on the AP pelvis radiograph and equatorial acetabular anteversion on CT for all hips. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of NAD. NAD is a valid semi-quantitative predictor of acetabular anteversion and strongly correlates with CT-measured equatorial acetabular anteversion (P  <  0.0001). A NAD measurement of greater than 14 mm predicts excessive acetabular anteversion with 76% sensitivity and 78% specificity. NAD is an accurate radiographic predictor of acetabular anteversion, which may be readily used as an effective screening tool during the evaluation of patients with hip pain. PMID:27026824

  8. Lateral acetabular labral length is inversely related to acetabular coverage as measured by lateral center edge angle of Wiberg.

    PubMed

    Petersen, Brian D; Wolf, Bryan; Lambert, Jeffrey R; Clayton, Carolyn W; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer

    2016-08-01

    Patients with developmental dysplasia of the hip often have compensatory labral hypertrophy, which presumably lends stability to an unstable joint. Conversely, patients with acetabular overcoverage may have small or ossified labra. The purpose of this study is to explore the interaction of labral length with the degree of acetabular hip coverage. A retrospective cohort of patients with hip pain presenting to a hip preservation center, who had undergone hip magnetic resonance imaging and AP pelvis radiographs were studied. General linear multivariate models were used to assess the association between three measures of labral length (lateral, anterior and anterior inferior locations along the acetabular rim) and the X-ray derived lateral center edge angle (LCEA) of Wiberg. Of the three acetabular labral locations measured, only the lateral labrum was associated with LCEA Wiberg (P = 0.0008). Lateral labral length increases as LCEA of Wiberg decreases. The anterior and anterior inferior labral locations did not show a predictable increase in labral length as LCEA Wiberg decreased. PMID:27583157

  9. Lateral acetabular labral length is inversely related to acetabular coverage as measured by lateral center edge angle of Wiberg

    PubMed Central

    Petersen, Brian D.; Wolf, Bryan; Lambert, Jeffrey R.; Clayton, Carolyn W.; Glueck, Deborah H.; Jesse, Mary Kristen; Mei-Dan, Omer

    2016-01-01

    Patients with developmental dysplasia of the hip often have compensatory labral hypertrophy, which presumably lends stability to an unstable joint. Conversely, patients with acetabular overcoverage may have small or ossified labra. The purpose of this study is to explore the interaction of labral length with the degree of acetabular hip coverage. A retrospective cohort of patients with hip pain presenting to a hip preservation center, who had undergone hip magnetic resonance imaging and AP pelvis radiographs were studied. General linear multivariate models were used to assess the association between three measures of labral length (lateral, anterior and anterior inferior locations along the acetabular rim) and the X-ray derived lateral center edge angle (LCEA) of Wiberg. Of the three acetabular labral locations measured, only the lateral labrum was associated with LCEA Wiberg (P = 0.0008). Lateral labral length increases as LCEA of Wiberg decreases. The anterior and anterior inferior labral locations did not show a predictable increase in labral length as LCEA Wiberg decreased. PMID:27583157

  10. Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims

    PubMed Central

    Wada, Hiroshi; Mishima, Hajime; Yoshizawa, Tomohiro; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    Background In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible because of direct palpation using a pointer. Imageless navigation using the ACA usually targets patients with normal acetabular morphology. The aim of this study was to investigate the accuracy of imageless navigation using the ACA instead of the APP in patients with normal or deformed acetabular rims. Methods The intraoperative cup position was compared with that obtained from the postoperative computed tomography (CT) images in 18 cases. Results The inclination angle derived from the navigation system was 3.4 ± 5.3 degrees smaller and the anteversion angle was 1.4 ± 3.1 degrees larger than those derived from the CT images. Conclusion The inclination cup angle of the navigation system was significantly inferior to the true value, particularly in cases with large anterior osteophytes. PMID:27073586

  11. Implication of acetabular width on the anteroposterior pelvic radiograph of patients with developmental dysplasia of the hip.

    PubMed

    Nie, Yong; Pei, Fuxing; Shen, Bin; Kang, Pengde; Li, Zongming

    2015-03-01

    Radiographic parameters that can help acetabular reconstruction during total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH) are few. The radiographs of 138 dysplastic hips that had undergone cementless THA were evaluated regarding the acetabular width above the acetabular component and the coverage of the component by native bone. The acetabular reconstruction process was simulated using 3D models from CT data, and the acetabular component coverage was calculated in 3D space based on the measurement and algorithm we proposed. Significant positive correlation between the acetabular width and the acetabular component coverage was found. Our study introduced a useful parameter, which can mark the superior reference position of the acetabular component for acetabular reconstruction in DDH patients. PMID:25311162

  12. An Isolated Displaced Fracture of the Coracoid Process Treated with Open reduction and internal fixation - A Case Report and Review of Literature

    PubMed Central

    Archik, Shreedhar; Nanda, Saurav Narayan; Tripathi, Sanjay; Choudhari, Ashlesh; Rajadhyaksha, Harshada

    2016-01-01

    Introduction: Isolated coracoid fractures are rare and few scattered cases are reported in literature. Coracoid fractures can be missed and the treatment for coracoid process fractures is still controversial. The case presented here is of an isolated coracoid process fracture which was treated surgically. Case Report: A 15-years old male presented after 4 days of injury complaining of persistent pain in the right shoulder following a jerk during bowling. Physical examination revealed tenderness in the left shoulder. There was pain on abduction and external rotation. The neurovascular examination was normal. Osseous avulsion of the distal tip of the coracoid process was confirmed by CT and MRI. The short head of the biceps and coracobrachialis was attached to the avulsed tip, while the pectoralis minor was attached to the coracoid base. The case was managed by open reduction and fixation with a 3.5mm cannulated screw and washer. Conclusion: Isolated coracoid fracture is a rare entity causing impairment of upper limb movement. It can be diagnosed more accurately by MRI scan and CT scan. In case of young highly demanding individuals like athletes surgical management may be a better option as compared to conservative treatment to achieve early use of the extremity, good radiological union and clinical function. PMID:27299123

  13. Orthodontic movement of a maxillary central incisor with a horizontal root fracture treated using an intra-radicular fibre splint

    PubMed Central

    Kapur, Aditi; Utreja, A.; Goyal, A.; Pankaj, P.

    2013-01-01

    This paper reports the case of a 15-year-old boy with a horizontal root fracture in the left maxillary central incisor along with class II division 1 malocclusion for whom a fixed orthodontic treatment was planned. The fracture was present at the junction of apical and middle-third as a result of trauma 2 years back. No splinting was carried out at that time and the tooth was found to be vital, asymptomatic and showed a type-1 repair pattern. An intentional root canal treatment was carried out for placement of an intra-radicular fiber splint, nearly 3 mm beyond the fracture line. Orthodontic treatment was initiated after a month; to which the fractured and splinted tooth responded successfully. This report highlights the successful use of an intra-radicular splint for horizontally fractured tooth requiring orthodontic treatment. PMID:24015026

  14. Effect of a crown ferrule on the fracture strength of endodontically treated canines restored with fiber posts and metal-ceramic or all-ceramic crowns.

    PubMed

    Evangelinaki, Evangelia; Tortopidis, Dimitrios; Kontonasaki, Eleana; Fragou, Theodora; Gogos, Christos; Koidis, Petros

    2013-01-01

    The aim of this study was to comparatively evaluate the fracture strength of endodontically treated canines restored with glass-fiber posts (GFPs) and either metal-ceramic (MC) or all-ceramic (AC) crowns in the presence or absence of 2 mm of ferrule height. Fifty human maxillary canines were endodontically treated and randomly divided into five groups of 10 specimens each. The first group remained intact (control), while the remainder were restored with GFPs and composite cores with either MC or AC crowns. Each of the AC and MC groups was equally divided between teeth with or without ferrule. Teeth were embedded in acrylic resin and loaded at a 135-degree angle to their long axis until fracture. Fracture strength was not significantly different between ferrule and no ferrule groups (P = .571), but was significantly larger for the MC groups compared with the control and AC groups (P = .009 and P = .024, respectively). A significant effect of the type of restoration was found as teeth restored with MC crowns presented significantly higher fracture strength, independently of ferrule. PMID:23837171

  15. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures

    PubMed Central

    2014-01-01

    Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833

  16. Bilateral femoral neck fractures secondary to chronic carbamazepine use treated by bilateral dynamic hip screw: A case report

    PubMed Central

    Sariyilmaz, Kerim; Gulenc, Baris; Ozkunt, Okan; Dikici, Fatih; Yazicioglu, Onder

    2014-01-01

    Introduction Bilateral femoral neck fractures without major trauma are rare and related to several conditions. Insufficiency fractures due to the use of anti-epileptic drug are one of the rare causes. This case study is about bilateral femoral neck insufficiency fractures resulting from chronic use of anti-epileptic drug. Presentation of case A 26-year-old woman was referred to our emergency department with a complaint of bilateral groin pain and a 12-year history of irregular carbamazepine use. The diagnosis was bilateral femoral neck insufficiency fractures due to irregular long-term carbamazepine use. One-stage bilateral dynamic hip screw osteosynthesis was performed. After 2 years of follow up, good result was obtained. Discussion There are several risk factors for insufficiency fracture, and antiepileptic drug related osteoporosis is one of the reason. These drugs have negative effect on bone methabolism and bone mineral density. Conclusion To our knowledge, this is the first case in the literature of bilateral femoral neck insufficiency fracture due to chronic carbamazepine use. Joint and bone pain with a history of long-term use of anti-epileptic drug should be investigated carefully, and insufficiency fractures should be kept in mind. PMID:25528039

  17. Effects of rotational acetabular osteotomy on the mechanical stress within the hip joint in patients with developmental dysplasia of the hip: a subject-specific finite element analysis.

    PubMed

    Ike, H; Inaba, Y; Kobayashi, N; Yukizawa, Y; Hirata, Y; Tomioka, M; Saito, T

    2015-04-01

    In this study we used subject-specific finite element analysis to investigate the mechanical effects of rotational acetabular osteotomy (RAO) on the hip joint and analysed the correlation between various radiological measurements and mechanical stress in the hip joint. We evaluated 13 hips in 12 patients (two men and ten women, mean age at surgery 32.0 years; 19 to 46) with developmental dysplasia of the hip (DDH) who were treated by RAO. Subject-specific finite element models were constructed from CT data. The centre-edge (CE) angle, acetabular head index (AHI), acetabular angle and acetabular roof angle (ARA) were measured on anteroposterior pelvic radiographs taken before and after RAO. The relationship between equivalent stress in the hip joint and radiological measurements was analysed. The equivalent stress in the acetabulum decreased from 4.1 MPa (2.7 to 6.5) pre-operatively to 2.8 MPa (1.8 to 3.6) post-operatively (p < 0.01). There was a moderate correlation between equivalent stress in the acetabulum and the radiological measurements: CE angle (R = -0.645, p < 0.01); AHI (R = -0.603, p < 0.01); acetabular angle (R = 0.484, p = 0.02); and ARA (R = 0.572, p < 0.01). The equivalent stress in the acetabulum of patients with DDH decreased after RAO. Correction of the CE angle, AHI and ARA was considered to be important in reducing the mechanical stress in the hip joint. PMID:25820887

  18. An In Vitro Comparative Evaluation of Fracture Resistance of Custom Made, Metal, Glass Fiber Reinforced and Carbon Reinforced Posts in Endodontically Treated Teeth

    PubMed Central

    Sonkesriya, Subhash; Olekar, Santosh T; Saravanan, V; Somasunderam, P; Chauhan, Rashmi Singh; Chaurasia, Vishwajit Rampratap

    2015-01-01

    Background: Posts are used to enhance crown buildup in pulpless teeth with destructed crown portion. Different types of post are used in endodontically treated teeth. The aim of the present in vitro study was to evaluate fracture resistance of custom made, metal, glass fiber reinforced and carbon reinforced posts in endodontically treated teeth. Materials and Methods: An in vitro study was carried out on extracted 40 human maxillary central incisor teeth, which was divided into four groups with 10 samples in each group with custom made, metal post, glass fiber reinforced, and carbon reinforced posts. The samples were decoronated at cemento-enamel junction and endodontically treated. Post space was prepared and selected posts were cemented. The composite cores were prepared at the height of 5 mm and samples mounted on acrylic blocks. Later fracture resistance to the compressive force of samples was measured using Universal Testing Machine. Results: The maximum resistance to the compressive force was observed in carbon reinforced and glass fiber reinforced posts compared others which is statistically significant (P > 0.001) and least was seen in custom fabricated post. Conclusion: It is concluded that carbon reinforced fiber post and glass fiber posts showed good fracture resistance compared to custom made and metal posts. PMID:26028904

  19. Debonding of porous coating of a threaded acetabular component: retrieval analysis.

    PubMed

    Łapaj, Łukasz; Markuszewski, Jacek; Rybak, Tomasz; Wierusz-Kozłowska, Małgorzata

    2013-01-01

    This report presents a case of debonding of plasma sprayed porous titanium coating from a threaded acetabular component which caused aseptic loosening of the implant. Weight bearing after delamination caused abrasive damage of the acetabular shell, and particles of the coating embedded in the acetabular liner. Microscopic examination of periprosthetic tissues showed presence of metal particles and macrophage infiltration. Despite microscopic examination of the retrieved component the cause of debonding remains unclear. PMID:23127634

  20. Redislocation After a Failed Surgery to Treat C6/7 Fracture-Dislocation With Pedicular Fracture of the C6 Vertebra: Case Report of a Successful Revision Surgery, Analysis of the Causes, and Discussion of Revision Surgical Strategies.

    PubMed

    Yang, Yi; Ma, Litai; Li, Tao; Liu, Hao

    2016-03-01

    Cervical spinal fracture-dislocation with pedicular fracture of the vertebra has been little reported and the management of such a patient is difficult. Considering the little knowledge of this area, we present this special case of a successful revision surgery for the treatment of redislocation after a failed surgery to treat C6/7 fracture-dislocation with pedicular fracture of the C6 vertebra to share our experience.A 45-year-old male patient presented to our hospital with history of neck pain for 4 months. According to his medical records, he was involved in an architectural accident and diagnosed with C6/7 fracture-dislocation with pedicular fracture of the C6 vertebra (ASIA: D). A surgery of posterior lateral mass screw fixation (bilateral in C5 and C7; left side in C6) was performed in a different institution. However, 4 months after his primary surgery, he was still troubled by serious neck pain and muscle weakness in all right side limbs. The physical examination of the patient showed hypoesthesia in the right side limbs, myodynamia of the right side limbs weakened to Grade 4. Cervical X-rays, computed tomography (CT), and magnetic resonance imaging confirmed the redislocation of C6/7. A successful revision surgery of anterior cervical corpectomy and fusion (ACCF) with nanohydroxyapatite/polyamide 66 composite fulfilled with vertebral autograft plus anterior plate was performed. The 3 months postoperative X-rays and CT scan showed the good position of the implant and bony fusion. The patient's neck pain was relived and the neurological function recovered to ASIA E grade at the 3rd month follow-up.ACCF with nanohydroxyapatite/polyamide 66 composite fulfilled with vertebral autograft plus anterior plate is effective for the treatment of redislocation after a failed surgery in patients of fracture-dislocation with pedicular fracture. The best method to avoid such a failed surgery is a combined anterior-posterior approach surgery in our opinion. PMID:26962843

  1. The reinforcement effect of polyethylene fibre and composite impregnated glass fibre on fracture resistance of endodontically treated teeth: An in vitro study

    PubMed Central

    Luthria, Archana; Srirekha, A; Hegde, Jayshree; Karale, Rupali; Tyagi, Sanjana; Bhaskaran, Sajeev

    2012-01-01

    Aim: The aim of this study was to evaluate the fracture resistance of endodontically treated maxillary premolars with wide mesio-occluso-distal (MOD) cavities restored with either composite resin, or composite resin reinforced with different types of fibres. Materials and Methods: Fifty human maxillary premolars were selected. Five intact teeth served as positive controls. Endodontic therapy was carried out in the remaining forty-five teeth. Standardized MOD cavities were prepared in all the teeth. The teeth were restored with a nanocomposite using an incremental technique. These forty five teeth were randomly divided into three experimental groups (Group A, B and C) (n = 15). The teeth in Group A did not undergo any further procedures. The teeth in Group B and C were reinforced with composite impregnated glass fibre and polyethylene fibre, respectively. Fracture resistance was measured in Newtons (N). Results: The positive controls showed the highest mean fracture resistance (811.90 N), followed by Group B (600.49N), Group A (516.96N) and Group C (514.64N), respectively. One Way analysis of variance (ANOVA) test revealed a statistically significant difference between all the groups (P = 0.001). Post-hoc Tukey test revealed a moderately significant difference (P = 0.034) between Control and Group B, and a strongly significant difference between Control and Group A (P = 0.002), and Control and Group C (P = 0.001). Conclusions: Endodontic therapy and MOD cavity preparation significantly reduced the fracture resistance of endodontically treated maxillary premolars (P = 0.001). No statistically significant difference was found between the experimental groups (Group A, B and C) (P > 0.1). However, the fracture resistance of the composite impregnated glass fibre reinforced group was much higher than the others. PMID:23112487

  2. Proximal Femoral Nail Antirotation Versus Reverse Less Invasive Stabilization System-distal Femur for Treating Proximal Femoral Fractures: A Meta-analysis.

    PubMed

    Jiang, Xuan; Wang, Ying; Ma, XinLong; Ma, JianXiong; Wang, Chen; Zhang, ChengBao; Han, Zhe; Sun, Lei; Lu, Bin

    2016-04-01

    The aim of this study was to compare the effectiveness and safety of 2 surgical techniques that are used to treat proximal femoral fractures.A systematic literature search (up to December 2014) was conducted in Medline, Embase, PubMed, and The Cochrane Central Register of Controlled Trials to screen for studies comparing proximal femoral nail antirotation (PFNA) with less invasive stabilization system-distal femur (LISS-DF) for proximal femoral fractures. Two authors independently assessed the methodological quality of the included studies and extracted data. Surgical information and postoperative outcomes were analyzed.A total of 7 studies with 361 patients who satisfied the eligibility criteria included 3 randomized controlled trials and 4 case-controlled trials associated with PFNA versus LISS in treating proximal femoral fractures. Our results demonstrated that there was a significant reduction in hospital stay and time to weight-bearing ambulation and bone healing for PFNA compared with LISS (odds ratio [OR] -1.48, 95% confidence interval [CI] -2.92 to -0.05; OR -7.08, 95% CI -8.32 to -5.84; OR -2.71, 95% CI -4.76 to 0.67). No statistically significant difference was observed between the 2 groups for operative time, blood loss volume, Harris hip score, and incidence of complications.Based on the results of this analysis, we inferred that PFNA is safer and more effective than reverse LISS-DF in patients undergoing osteosynthesis for proximal femoral fractures, and that PFNA is associated with reduced hospital stays and reduced time to weight-bearing ambulation and bone healing. Nonetheless, in certain cases in which PFNA is not suitable due to abnormal structure of the proximal femur or particularly unstable fractures, the LISS plate technique could be a useful alternative. PMID:27057840

  3. Difference in the acetabular cup orientation in standing and supine radiographs.

    PubMed

    Khan, Munir; Beckingsale, Tom; Marsh, Martin; Holland, Jim

    2016-09-01

    Acetabular orientation changes with that of the pelvis during lying and standing. This study was designed to measure these changes. We assessed 17 BHR replacements using EBRA software. The mean acetabular anteversion was more (p = 0.02) on erect than supine radiographs. Linear regression analysis showed that anteversion and inclination increased in some while decreased in others, and Bland and Altman analysis showed wide limits of agreement. The changes in acetabular orientation are thus subject to significant variations between the patients. We suggest studying the factors affecting acetabular orientation in standing to help reduce joint reaction forces and improve outcomes. PMID:27408490

  4. Skin Entrapment in an Un-displaced Proximal Humerus Fracture Treated with Closed Reduction; A Case Report

    PubMed Central

    Hughes, Michael; Frasquet-Garcia, Antonio; Ismail, Mobeen; Waseem, Mohammad

    2016-01-01

    Background: Proximal humerus fractures are a common presentation to Orthopaedic services in the United Kingdom, and the incidence is increasing. Proximal humerus fractures are usually associated with low energy trauma in elderly patients. There is a sub-set of younger patients who suffer low energy fractures due to underlying osteopenia, commonly associated with alcohol excess. Skin puckering or dimpling has been described as a very rare complication of proximal humerus fracture. Based on the few previously published reports of this complication, skin entrapment in proximal humerus fracture is usually predictive of failure of closed reduction, and need for open surgery. Methods: Literature searches were carried out for relevant keywords. Articles were then critically appraised before being included in the literature review. Results: The Authors were only able to identify three previous reports of this rare complication. Conclusion: The authors describe a rare case of skin interposition in an un-displaced proximal humerus fracture, outline a technique for closed reduction, and review the current literature surrounding this rare complication. PMID:27347240

  5. The new concept of the monitoring and appraisal of bone union inflexibility of fractures treated by Dynastab DK external fixator.

    PubMed

    Lenz, Gerhard P; Stasiak, Andrzej; Deszczyński, Jarosław; Karpiński, Janusz; Stolarczyk, Artur; Ziółkowski, Marcin; Szczesny, Grzegorz

    2003-10-30

    Background. This work focuses on problems of heuristic techniques based on artificial intelligence. Mainly about artificial non-linear and multilayer neurons, which were used to estimate the bone union fractures treatment process using orthopaedic stabilizers Dynastab DK. Material and methods. The author utilizes computer software based on multilayer neuronal network systems, which allows to predict the curve of the bone union at early stages of therapy. The training of the neural net has been made on fifty six cases of bone fracture which has been cured by the Dynastab stabilizers DK. Using such trained net, seventeen fractures of long bones shafts were being examined on strength and prediction of the bone union as well. Results. Analyzing results, it should be underlined that mechanical properties of the bone union in the slot of fracture are changing in nonlinear way in function of time. Especially, major changes were observed during the forth month of the fracture treatment. There is strong correlation between measure number two and measure number six. Measure number two is more strict and in the matter of fact it refers to flexion, as well as the measure number six, to compression of the bone in the fracture slot. Conclusions. Consequently, deflection loads are especially hazardous for healing bone. The very strong correlation between real curves and predicted curves shows the correctness of the neuronal model. PMID:17679847

  6. Percutaneous limited internal fixation combined with external fixation to treat open pelvic fractures concomitant with perineal lacerations.

    PubMed

    Chen, Linwei; Zhang, Guoyou; Wu, Yaoshen; Guo, Xiaoshan; Yuan, Wen

    2011-12-01

    External fixation combined with colostomy is a traditional management of the pelvic fractures associated with perineal lacerations. However, malunion and dysfunction caused by malreduction and loss of reduction are common. One-stage definitive fixation without soft tissue harassment is requisite for the treatment. The purpose of this study was to assess the outcome of 1-stage definitive fixation by combining percutaneous limited internal fixation and external fixation in the treatment of pelvic fractures with perineal lacerations. Eighteen adults with high-energy unstable pelvic ring fractures associated with perineal lacerations were admitted between June 2003 and December 2010. Mean follow-up was 28 months. After wound closure and colostomy, 10 patients received external fixation and percutaneous screw fixation, and 8 patients underwent external fixation. Demographics, wound and fracture classification, and Injury Severity Score were comparable between the groups (P>.05). Initial reduction quality was comparable between the groups (P=.14), but the loss of reduction during follow-up was more significant in the external fixation group (P=.004). Combined fixation achieved better functional results than external fixation (P=.02). There were 2 cases of superficial wound infection in each group (P=1.0). By combining debridement, wound closure, colostomy, percutaneous limited internal fixation, and external fixation, we improved pelvic fracture recovery while reducing the risk of infection. One-stage definitive fixation is a better choice than external fixation in the treatment of open pelvic fracture concomitant with perineal wound. PMID:22146197

  7. Acetabular component deformation with press-fit fixation.

    PubMed

    Squire, Matthew; Griffin, William L; Mason, J Bohannon; Peindl, Richard D; Odum, Susan

    2006-09-01

    Acetabular component deformation secondary to forces encountered during insertion is a potential consequence of the press-fit technique. This study characterized the stiffness of Pinnacle 100 cups (DePuy, Warsaw, Ind) via mechanical testing and used this information with intraoperative measurements of cup deformation to calculate the in vivo forces acting on cups inserted during hip arthroplasty in 21 patients. We found that 90.5% of cups had measurable compression deformity, averaging 0.16 +/- 0.16 mm. The corresponding forces acting on these cups averaged 414 +/- 421 N. For hard-on-hard bearing surfaces, such in vivo deformation of acetabular shells may result in negative clinical consequences such as equatorial loading with increased wear and potential seizing of components, chipping of ceramic inserts, or locking mechanism damage. PMID:16950065

  8. Arthroscopic repair of acetabular chondral delamination with fibrin adhesive.

    PubMed

    Tzaveas, Alexandros P; Villar, Richard N

    2010-01-01

    Acetabular chondral delamination is a frequent finding at hip arthroscopy. The cartilage is macroscopically normal but disrupted from the subchondral bone. Excision of chondral flaps is the usual procedure for this type of lesion. However, we report 19 consecutive patients in whom the delaminated chondral flap was re-attached to the underlying subchondral bone with fibrin adhesive. We used the modified Harris hip score for assessment of pain and function. Improvement in pain and function was found to be statistically significant six months and one year after surgery. No local or general complications were noted. Three patients underwent further surgery for unrelated reasons. In each, the area of fibrin repair appeared intact and secure. Our results suggest that fibrin is a safe agent to use for acetabular chondral delamination. PMID:20235074

  9. Profile Measurement of Worn Acetabular Cup by Holographic Contouring

    NASA Astrophysics Data System (ADS)

    Kakunai, Satoshi; Sakamoto, Tohoru; Sakurai, Daisuke; Aota, Yuuki; Shelton, Julia

    Wear in a polyethylene acetabular cup is dependent on the history of the cup, namely on the sterilization treatment, initial mounting situation, the patient's lifestyle and length of time in vivo. Understanding wear patterns is essential in order to prevent inflammation and prosthesis failure. This study describes the profile measurement of a worn acetabular cup by holographic contouring, which can provide non-contact measurement over the entire visual field. Experiments were performed to verify the method, and measurements of cups worn in vivo were carried out. Cup profile was investigated using holograms obtained in three directions and changes in cup profile were evaluated using fringe patterns in which the interval range was adjusted from tens of microns to several millimeters.

  10. Acetabular Paralabral Cyst: An Unusual Cause of Femoral Vein Compression

    PubMed Central

    Kullar, Raj S.; Kapron, Ashley L.; Ihnat, Daniel; Aoki, Stephen K.; Maak, Travis G.

    2015-01-01

    Acetabular labral tears are a known cause of hip pain in the young, active patient. Labral tears can be due to trauma, femoroacetabular impingement, capsular laxity, dysplasia, and degenerative pathology. Paralabral cysts are relatively common in association with labral tears of the hip, with cysts seen on magnetic resonance imaging studies in as many as 50% to 70% of patients with labral tears. In some cases the cysts can become sizeable and cause neurovascular compression. Nonoperative interventions for the management of paralabral cysts in the shoulder and knee have shown high recurrence rates. In the shoulder and knee, arthroscopic debridement of paralabral cysts has shown good results with lower recurrence rates and resolution of neurovascular function. In the hip there is limited literature regarding surgical management of paralabral cysts. We present a surgical technique for arthroscopic decompression of acetabular paralabral cysts combined with labral repair. PMID:25973371

  11. Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns

    PubMed Central

    SHERFUDHIN, Haneef; HOBEICH, Joseph; CARVALHO, Carlos Augusto; N. ABOUSHELIB, Moustafa; SADIG, Walid; SALAMEH, Ziad

    2011-01-01

    Objective This study investigated the effect of different ferrule heights on endodontically treated premolars. Materials and Methods Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal section was restored with hybrid composite core build-up material (Tetric Ceram, Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights were investigated: 1-mm circumferential ferrule without post and core (group 1 used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule 2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and 2-mm lingually (group 4), and finally no ferrule preparation (group 5). The fracture load and failure pattern of the tested groups were investigated by applying axial load to the ceramic crowns (n=10). Data were analyzed statistically by one-way ANOVA and Tukey’s post-hoc test was used for pair-wise comparisons (α=0.05). Results There were no significant differences among the failure load of all tested groups (P<0.780). The control group had the lowest fracture resistance (891.43±202.22 N) and the highest catastrophic failure rate (P<0.05). Compared to the control group, the use of fiber post reduced the percentage of catastrophic failure while increasing the ferrule height did not influence the fracture resistance of the restored specimens. Conclusions Within the limitations of this study, increasing the ferrule length did not influence the fracture resistance of endodontically treated teeth restored with glass ceramic crowns. Insertion of a fiber post could reduce the percentage of catastrophic failure of these restorations under function. PMID:21437466

  12. Basic considerations for determining the amount of press fit in acetabular cup endoprostheses as a function of the elastic bone behavior.

    PubMed

    Winter, Werner; Karl, Matthias

    2014-10-01

    Acetabular cup endoprostheses are frequently placed in pelvic bone, employing the mechanical principle of press fit. While a sufficiently stable bone-implant connection is desirable, deformation of the cup and fracture of the pelvis should be avoided. The goal of this work is to demonstrate the importance of the elastic properties of bone on the amount of press fit achievable in a specific situation. On the basis of previous work describing the relation between relative bone mineral density and relative elastic modulus for cortical and trabecular bone, mechanical equations were used for analyzing the press-fit loading situation of an acetabular cup. Additionally, a two-dimensional finite element model was used for visualizing the stress and strain situation in the host bone occurring as a consequence of implant insertion, as well as the effect of moment loads acting on the acetabular cup. Given the fact that oversizing the implant for a specific recipient site is the only clinical means of optimizing press fit, knowledge of the elastic properties of the host bone before implant selection would be beneficial. Such information could, for instance, be derived from intraoperative compressive testing of the host bone. PMID:24937501

  13. Comparative Evaluation of Fracture Resistance of Endodontically Treated Teeth Obturated with Resin Based Adhesive Sealers with Conventional Obturation Technique: An In vitro Study

    PubMed Central

    Langalia, Akshay K; Dave, Bela; Patel, Neeta; Thakkar, Viral; Sheth, Sona; Parekh, Vaishali

    2015-01-01

    Background: To compare fracture resistance of endodontically treated teeth obturated with different resin-based adhesive sealers with a conventional obturation technique. Materials and Methods: A total of 60 Single canaled teeth were divided into five groups. The first group was taken as a negative control. The rest of the groups were shaped using ProFile rotary files (Dentsply Maillefer, Ballaigues, Switzerland). The second group was obturated with gutta-percha and a ZOE-based sealer Endoflas FS (Sanlor Dental Products, USA). The third group was obturated with gutta-percha and an epoxy-based sealer AH Plus (Dentsply, DeTrey, Germany). The fourth group was obturated with Resilon (Pentron Clinical Technologies, Wallingford, CT) and RealSeal sealer (Pentron Clinical Technologies). The fifth group was obturated with EndoREZ points and EndoREZ sealer (both from Ultradent, South Jordan, UT). Roots were then embedded into acrylic blocks and were then fixed into a material testing system and loaded with a stainless steel pin with a crosshead speed of 5 mm/min until fracture. The load at which the specimen fractured was recorded in Newtons. Results: It was found that forces at fracture were statistically significant for the newer resin systems, Resilon, and EndoREZ. Conclusion: It was concluded that roots obturated with newer resin systems (Resilon and EndoREZ) enhanced the root strength almost up to the level of the intact roots. PMID:25859099

  14. Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.

    PubMed

    Ellenrieder, Martin; Bader, Rainer; Bergschmidt, Philipp; Mittelmeier, Wolfram

    2016-03-01

    Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred. PMID:26984655

  15. The effect of incomplete crown ferrules on fracture resistance and failure modes of endodontically treated maxillary incisors restored with quartz fiber post, composite core, and crowns

    PubMed Central

    Muangamphan, Panorjit; Sattapan, Boonrat; Kukiattrakoon, Boonlert; Thammasitboon, Kewalin

    2015-01-01

    Aim: To investigate the fracture resistance of restored endodontically treated teeth (RETT) with fiber posts, cores, and crowns with limited ferrules. Materials and Methods: Sixty maxillary anterior teeth were endodontically treated and decoronated 2 mm above the cemento-enamel junction, and then divided into 6 groups of 10 teeth each; Group circumferential ferrule (2FR), Group ferrule in the labial, mesial, and palatal region (2FR-LaMPa), Group ferrule in the labial, and palatal region (2FR-LaPa), Group 2FR-Pa and 2FR-La respectively, and Group 0FR (no ferrule). All 60 prepared teeth were then restored with quartz fiber posts, resin composite cores, and metal crowns. The specimens were subjected to load until failure occurred. Data were analyzed using one-way analysis of variance and Tukey's tests (α = 0.05). The mode of failure was determined under a stereoscope. Results: A statistical significant difference was found among groups 2FR-LaMPa, 2FR-Pa, 2FR-LaPa, and 2FR from the group 2FR-La, and from the group 0FR (P < 0.01). The predominant mode of failure was an oblique palatal to labial root fracture for the groups with remaining ferrules. Conclusion: For RETT that have incomplete crown ferrules, the location of the ferrules may affect their fracture resistance. PMID:26069401

  16. Fracture Resistance of Endodontically-treated Maxillary Premolars Restored with Composite Resin along with Glass Fiber Insertion in Different Positions

    PubMed Central

    Jafari Navimipour, Elmira; Ebrahimi Chaharom, Mohammad Esmaeel; Alizadeh Oskoee, Parnian; Mohammadi, Narmin; Bahari, Mahmoud; Firouzmandi, Maryam

    2012-01-01

    Background and aims The aim was to evaluate the effect of three methods of fiber insertion on fracture resistance of root-filled maxillary premolars in vitro. Materials and methods Sixty extracted human maxillary premolars received endodontic treatment followed by preparation of mesioocclusodistal (MOD) cavities, with gingival cavosurface margin 1.5 mm coronal to the cementoenamel junction (CEJ). Subsequently, the samples were randomly divided into four groups: no-fiber group; occlusal fiber group (fiber was placed in the occlusal third); circumferential fiber group (fiber was placed circumferentially in the cervical third); and dual-fiber group (occlusal and circumferential fibers). Subsequent to restoring with composite resin and thermocycling, a compressive force was applied until fracture. Data was analyzed using one-way ANOVA and Tukey test at significance levels of P < 0.05 and P < 0.02, respectively. Results Fiber placement significantly increased fracture resistance. Fracture resistance in the dual-fiber group was significantly higher than that in the circumferential fiber group (P < 0.007); however, there were no significant differences between the dual-fiber and occlusal fiber groups (P = 0.706). The highest favorable fracture rate was observed in the circumferential fiber group (60%). Conclusion Composite resin restoration along with glass fiber in the occlusal and gingival thirds can be an acceptable treatment option for restoring root-filled upper premolars. PMID:23277858

  17. Thrombosis of the External Jugular Vein: A Rare Complication of a Proximal Humerus Fracture Treated with Collar and Cuff Immobilisation

    PubMed Central

    Montgomery, Helen; Pickering, Simon

    2014-01-01

    We report the case of an 87-year-old woman who developed a thrombosis of her external jugular vein after sustaining a proximal humerus fracture managed nonoperatively with a collar and cuff. At review in fracture clinic she was found to have an enlarged external jugular vein which was subsequently found to be thrombosed. Her collar and cuff had been applied very tightly and it was felt by the ENT team to be the cause of the thrombosis of her external jugular vein. She was fully anticoagulated with warfarin after subsequently developing a deep vein thrombosis in the subclavian and axillary veins. She made a full recovery following anticoagulation. In this case, we review the potential causes of this rare and underdiagnosed condition, as well as the usual investigations and treatments. We also review the common complications of this fracture and the alternative treatment options available. PMID:25247102

  18. Outcome of intertrochanteric fractures treated by intramedullary nail with two integrated lag screws: A study in Asian population

    PubMed Central

    Kim, Jong-Won; Kim, Tae-Young; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2015-01-01

    Background: The incidence of intertrochanteric fracture has increased during recent years as life expectancy has also increased. Currently, orthopedic surgeons use various fixation methods for intertrochanteric fractures like, intramedullary (IM) nailing or dynamic hip screws and plates. The intramedullary (IM) nail with two integrated lag screws has been used recently in intertrochanteric fractures to overcome Z-affect phenomenon. However, no study is available in an Asian population. This prospective study was undertaken to document the clinical and radiologic outcomes of the IM nail with two integrated lag screws and its limitations in Asian patients. Materials and Methods: Osteosynthesis was performed using InterTAN nail in 100 patients with an intertrochanteric fractures followed up for at least 1 year after surgery. We evaluated the recovery rates to prefracture status, time to bony union and the incidence of complications. Results: Seventy four patients were available for at least 1 year followup examinations. Forty-five patients (60.8%) recovered prefracture status. Mean time to bony union was 18.3 ± 8.6 weeks. Intraoperative technical problems related to an unavoidable superior positioning of the lag screw occurred in five cases. Postoperative complications requiring reoperation occurred in three patients; two cases of varus collapse with cut out and one case of periprosthetic fracture. Conclusions: The IM nail with two integrated lag screws showed favorable outcomes in Asian patients with an intertrochanteric fracture even though several complications that were not previously reported with this nail were found. The proper selection of patients and careful insertion of two lag screws should be mandatory in Asian patients. PMID:26229165

  19. The Role of Lunate Morphology on Scapholunate Instability and Fracture Location in Patients Treated for Scaphoid Nonunion

    PubMed Central

    Kim, Byoung-Jin; Kovacevic, David; Lee, Young-Min; Seol, Jong-Hwan

    2016-01-01

    Background To determine the association between lunate morphology and the scapholunate instability using radiographic images, and investigate the association between lunate morphology and scaphoid fracture location. Methods Between January 2003 and December 2011, we retrospectively evaluated the plain radiographs and computed tomography (CT) images of 70 patients who underwent surgical intervention for a scaphoid nonunion, in order to determine the association between lunate type (I or II) and scapholunate instability or scaphoid fracture location. We determined the scaphoid fracture location using the fragment ratio and measured the radiolunate angle and capitate-triquetrum (C-T) distance. Results A type II lunate was present in 68.6% (48 of 70 cases). Mean fragment ratio of fracture location was 50.6% in the type II lunate group and 56.2% in the type I lunate group (p = 0.032). Sixteen of the 70 patients had dorsal intercalated segmental instability (DISI) deformities. Nine of 22 cases showed DISI deformity in type I lunate and 7 of 48 cases showed DISI deformity in type II lunate (p = 0.029). However, there were no significant differences between the presence of DISI deformity and fracture location (p = 0.15). Morphologic comparisons by both plain radiography and CT indicated a mean C-T distance in the type I lunate group (22 cases) of 2.3 mm and 5.0 mm in the type II lunate group (48 cases). The C-T distances were significantly correlated with lunate morphology (p = 0.001). Conclusions A type II lunate was associated with low incidence of DISI deformity and proximal location of fracture in patients presenting with a scaphoid nonunion. PMID:27247743

  20. A Case of Nasu-Hakola Disease without Fractures or Consanguinity Diagnosed Using Exome Sequencing and Treated with Sodium Valproate

    PubMed Central

    Yamazaki, Kiyohiro; Yoshino, Yuta; Mori, Yoko; Ochi, Shinichiro; Yoshida, Taku; Ishimaru, Takashi; Ueno, Shu-ichi

    2015-01-01

    Nasu-Hakola disease (NHD) is a rare autosomal recessive neuropsychiatric disorder characterized by bone cysts, fractures, and cognitive impairment. Two genes are responsible for the development of NHD; TYROBP and TREM2. Although it presents with typical signs and symptoms, diagnosing this disease remains difficult. This case report describes a male with NHD with no family or past history of bone fractures who was diagnosed using exome sequencing. His frontal lobe psychiatric symptoms recovered partially following treatment with sodium valproate, but not with an antipsychotic. PMID:26598595

  1. Fracture resistance of endodontically treated maxillary premolars restored by silorane-based composite with or without fiber or nano-ionomer

    PubMed Central

    Shafiei, Fereshteh; Ghahramani, Yasamin; Fattah, Zahra

    2014-01-01

    PURPOSE This in vitro study investigated the fracture resistance of endodontically treated premolars restored using silorane- or methacrylate-based composite along with or without fiber or nano-ionomer base. MATERIALS AND METHODS Ninety-six intact maxillary premolars were randomly divided into eight groups (n = 12). G1 (negative control) was the intact teeth. In Groups 2-8, root canal treatment with mesio-occlusodistal preparation was performed. G2 (positive control) was kept unrestored. The other groups were restored using composite resin as follows: G3, methacrylate-based composite (Z250); G4, methacrylate composite (Z250) with polyethylene fiber; G5 and G6, silorane-based composite (Filtek P90) without and with the fiber, respectively; G7 and G8, methacrylate- and silorane-based composite with nano-ionomer base, respectively. After aging period and thermocycling for 1000 cycles, fracture strength was tested and fracture patterns were inspected. The results were analyzed using ANOVA and Tukey HSD tests (α=0.05). RESULTS Mean fracture resistance for the eight groups (in Newton) were G1: 1200 ± 169a, G2: 360 ± 93b, G3: 632 ± 196c, G4: 692 ± 195c, G5: 917 ± 159d, G6: 1013 ± 125ad, G7: 959 ± 148d, G8: 947 ± 105d (different superscript letters revealed significant difference among groups). Most of the fractures in all the groups were restorable, except Group 3. CONCLUSION Silorane-based composite revealed significantly higher strength of the restored premolars compared to that of methacrylate one. Fiber insertion demonstrated no additional effect on the strength of both composite restorations; however, it increased the prevalence of restorable fracture of methacrylate-based composite restored teeth. Using nano-ionomer base under methacrylate-based composite had a positive effect on fracture resistance and pattern. Only fiber-reinforced silorane composite restoration resulted in a strength similar to that of the intact teeth. PMID:25006384

  2. Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement

    PubMed Central

    Li, Junwei; Gao, Xu; Yang, Guanghui; Zhang, Yanru

    2015-01-01

    Positions of acetabular implant generally are considered to be major causative factors of dislocation. Accurate and consistent achievement of the preoperatively anticipated orientation of the acetabular cup is a great challenge in total hip replacement (THR). In the present study, we investigated the surgical application of acetabular fossa as a guide for anticipated inclination of uncemented cup, and evaluated its accuracy as an anatomic reference for achieving the preoperatively anticipated abduction of the acetabular cup in comparison with traditional device method on cadaveric specimens. Sixteen normal adult pelvic cadaveric specimens were collected. On each of the sixteen normal adult pelvic cadaveric specimens, acetabular fossa related anatomic sites were marked and studied on pelvic radiographs. Our results showed that there is close correlation between most medial aspect of acetabular sourcil and central axis of the acetabular cup at anticipated inclination of 40° ± 5°. And the fossa group can achieve the preoperatively anticipated cup abduction more accurately than the device group. The current results demonstrated that acetabular fossa can be a reasonable alternative, or as a complement to the currently used methods guiding total hip replacement. PMID:25784987

  3. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  4. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  5. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  6. Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology.

    PubMed

    Peters, Frank M; Greeff, Richard; Goldstein, Neal; Frey, Chris T

    2012-08-01

    Acetabular cup placement in total hip arthroplasty is often difficult to assess, especially in the lateral position and using the posterior approach. Conventional techniques and computer-assisted surgery are the 2 most popular methods for proper placement of the acetabular cup in Lewinnek's safe zone of orientation (anteversion 15° ± 10° and lateral inclination 40° ± 10°). We developed a system that uses the accelerometer and camera function of the iPhone. A level indicator application and protractor application were downloaded to the iPhone and used to improve acetabular cup placement. This system has proven to be accurate and quick. Our series of 50 prospective cases showed good results with all our acetabular cups being placed within a narrow range in the safe zone and with less than 5% difference between the preoperative, intraoperative, and postoperative acetabular inclinations. PMID:22245126

  7. Arthroscopic Technique for Chondrolabral Capsular Preservation During Labral Repair and Acetabular Osteoplasty

    PubMed Central

    Nwachukwu, Benedict U.; McCormick, Frank; Martin, Scott D.

    2013-01-01

    Traditional techniques for acetabular osteoplasty in femoral acetabular impingement have required surgical detachment of the labrum at the chondrolabral junction. Such approaches compromise labral blood flow and contribute to a limited ability for healing at the chondrolabral junction. In this technical note and accompanying video, we present a technique for preservation of the chondrolabral junction during labral repair and acetabular osteoplasty. We elevate the chondrolabral complex subperiosteally off the acetabular rim, and the acetabular shelf is then contoured under fluoroscopic guidance. The labrum is then repaired and reconstituted to a new anatomic footprint. We find this technique to be advantageous because it preserves the blood flow to the labrum, thereby maximizing healing potential. Outcome studies are warranted to further elucidate the functional and outcome benefits of this surgical technique. PMID:24265986

  8. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    PubMed

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction. PMID:24350878

  9. Early results of displaced supracondylar fractures of humerus in children treated by closed reduction and percutaneous pinning

    PubMed Central

    Sharma, Anmol; Walia, Jaswinder P S; Brar, Bhupinder S; Sethi, Sudhir

    2015-01-01

    Background: Displaced supracondylar fractures are notorious for difficulty in reduction, maintenance of reduction and frequent involvement of neurovascular structures. No general agreement on the treatment is evident with controversy prevailing regarding the ideal timing of surgery, method of maintenance of reduction and configuration of the pin fixation. A crossed pin configuration, though believed by some to be mechanically more stable than the lateral pins alone, has the risk of ulnar nerve injury due to the medial pin. Lateral pins alone impart less rotational stability to the fracture although it has been attributed mainly to technical errors of pin placement. The aim of this study was to assess the efficacy of treatment of this fracture using one lateral and one trans-olecranon K-wires or lateral entry K-wires alone. Materials and Methods: Ninety cases of displaced supracondylar humerus fractures were included in the study. The mean age of the patients was 6.7 years (range 3–12 years). The male/female ratio was 5:1 and left side was involved in 70% whereas 30% had right sided injuries. The most common mode of trauma was fall from height with elbow in extension. All the 90 consecutively admitted patients had extension type injury with 73.3% fractures being Gartland type III and 26.7% were type II. Posteromedial displacement was noted in 70% whereas 30% fractures were posterolaterally displaced. In 60 cases, lateral entry wires alone were used whereas, in 30 cases, one lateral and another transolecranon transarticular K-wire was used. K-wires were removed at 3 weeks postoperatively and followup was done at 6 weeks and 12 weeks when they were evaluated according to the criteria described by Flynn. Chi-square test was used as a statistical test of significance to compare results among different variables. Results: Results were graded according to Flynn's criteria. Excellent results were achieved in 12 (13.3%), good in 54 (60%), fair in 15 (16.7%) while in nine

  10. Displaced tibia shaft fractures in children treated by elastic stable intramedullary nailing: results and complications in children weighing 50 kg (110 lb) or more.

    PubMed

    Marengo, Lorenza; Paonessa, Matteo; Andreacchio, Antonio; Dimeglio, Alain; Potenza, Alberto; Canavese, Federico

    2016-04-01

    The main objective of this study was to retrospectively evaluate the clinical and radiographic outcomes of displaced tibia shaft fractures in children weighing 50 kg (110 lb) or more treated by elastic stable intramedullary nailing (ESIN). Translation, sagittal and coronal angulations were assessed on plain radiographs in all the patients. Twenty-six out of 106 patients met the inclusion criteria. The average patient age at the time of injury was 13.5 ± 1.3 years (range 11.3-16.1). The mean patient weight was 57 ± 8 kg (range 50-80). This study demonstrates that the use of ESIN for displaced tibia shaft fractures in children and adolescents weighing 50 kg (110 lb) or more, or older than 13 years of age, is not contraindicated. In contrast to data in femoral shaft fractures, we did not find poorer outcomes in older or heavier patients. No correlation between nail size/medullary canal diameter ratio and outcome was observed. PMID:26662289

  11. Use of Cemented Spacer with a Handmade Stem to Treat Acute Periprosthetic Tibial Fracture Infection: A Case Report

    PubMed Central

    Font-Vizcarra, LluÍs; Izquierdo, Oscar; GarcÍa-NuÑo, Laura; GonzÁlez, Araceli; Diaz-Brito, VicenÇ; Castellanos, Juan

    2014-01-01

    We report an 85-year-old woman with dementia and dependent for normal life activities who was admitted due to a left periprosthetic tibial fracture. The tibial component was replaced by one with a long stem and she was discharged. Four weeks after the intervention the patient was re-admitted due to an acute prosthetic joint infection. All the components were removed and a bone-cement spacer with a handmade stem with a metal core was implanted. Radiological signs of fracture consolidation were observed after 3 months of follow-up. Due to the previous health status of the patient, it was decided to keep the spacer as a definitive treatment. After 24 months, the patient was able to sit without pain and to stand up with help using a knee brace. There were no radiological or clinical signs of infection. PMID:24551027

  12. Anterior Reduction, Discectomy, and Three Cortical Iliac Bone Grafting With Instrumentation to Treat A Huge Tear Drop Fracture of the Axis

    PubMed Central

    Ma, Litai; Yang, Yi; Gong, Quan; Ding, Chen; Liu, Hao; Hong, Ying

    2016-01-01

    Abstract Fractures of the axis body have been little reported and treatment strategies remain controversial and individualized. Not more than 10 cases of huge tear drop fracture of the axis (HTDFA) have been reported in previous studies and the treatment method varies from conservative treatment to an anterior, or posterior, approach surgery. Considering the sparse knowledge of HTDFA, we present a special case report to share our experience and to explore the safety and effectiveness of anterior reduction and fusion to treat HTDFA. A 24-year-old man was referred to our department; he presented with neck pain lasting for 12 h since being involved in a roll-over motor vehicle accident. His neck movement was limited but there was no neurological compromise. Physical examination of the patient showed myodynamia of four limbs Grade 5, Hoffmann sign (–), and Babinski sign (–). Three-dimensional reconstruction computed tomography (CT) confirmed a huge tear drop fracture of the anterior–inferior corner of the axis and discontinuity of the cortex of the axis. After discussion with the spinal surgeon team in the department and an effective conversation with the patient, surgery involving anterior reduction, discectomy, and three cortical iliac bone grafts with instrumentation after transnasal induction of general anesthesia was performed. The patient was instructed to wear a cervical collar until he returned to our department for a follow-up examination some 3 months after surgery. The 3-month postoperative x-ray and CT scan showed a good position of the implant and bony fusion at the C2/3 segment. Anterior reduction, discectomy, and three cortical iliac bone grafts with instrumentation to treat HTDFA are effective, safe, and simple. Of course, longer follow-up duration and more cases are warranted to verify this procedure. Anterior reduction, discectomy, and bone grafting with instrumentation are warranted for most HTDFA cases. However, if HTDFA incorporates other

  13. A Gustilo type IIIB open forearm fracture treated by negative pressure wound therapy and locking compression plates: a case report.

    PubMed

    Takeuchi, Naohide; Mae, Takao; Hotokezaka, Shunsuke; Sasaki, Kosuke; Matsushita, Akinobu; Miake, Go; Kuchiishi, Rintaro; Noguchi, Yasuo

    2011-10-01

    A 91-year-old female sustained injuries to her left forearm while walking across a crosswalk. X-rays showed left radial shaft and ulna shaft fractures, and the injury was a type IIIB open fracture. On the day of admission, irrigation and debridement of the open wound, and temporary fixation of the radius and ulna using an external fixator and a Kirschner wire were peformed. Six days after the surgery, we used negative pressure wound therapy (NPWT) using the V.A.C.ATS system for the open wound. Thirteen days after the first surgery, definitive fixation was performed by using locking compression plates, and full thickness skin grafting was undertaken for the open wound. NPWT is a treatment that accelerates the wound healing process through the delivery of continuous subatmospheric pressure within a closed environment. In our case, we could reduce the healing period of the soft tissue and could convert to the definitive fixation in a timely fashion. NPWT is thought to be a useful adjunct in the management of the soft tissues of open fractures. PMID:22171501

  14. Computed Tomography-Based Software Safely Guides Anterograde Percutaneous Anterior and Posterior Column Acetabular Screws.

    PubMed

    Banerjee, Soham; Starr, Adam J; Banerjee, Rahul

    2016-01-01

    The objective of this study was to develop three-dimensional (3-D) modeling software to generate the optimal individualized starting points and pathways for anterior and posterior column screws. In this cross-sectional study, 95 consecutive patients from a level I trauma center with noncontrast pelvis computed tomography (CT) images without displaced acetabular fractures were studied. A Java-based program was designed that generated a 3-D graph of pelvic bones and a list was compiled of every potential anterograde anterior and posterior column screw that exited distal to the acetabulum, eliminating screws that did not safely remain within the cortex. The longest safe screw pathway for each patient was determined for both 6.5-mm and 7.3-mm diameter screws. The program was able to identify safe screw pathways for the vast majority of patients (>96%). The study also found that males tolerated significantly longer screws in the anterior column (p < .05), but there was no posterior column difference regarding sex. PMID:27518290

  15. Is labral hypotrophy correlated with increased acetabular depth?

    PubMed

    Toft, Felix; Anliker, Elmar; Beck, Martin

    2015-07-01

    Labral hypertrophy is a distinct feature in hip dysplasia. Occasionally, very small, hypotrophic labra are observed. However, there is no literature concerning this pathology. We investigated if the size of the labrum correlated with any radiologic parameters reflecting the amount of acetabular coverage. It was hypothezised that there is a negative correlation between labrum size and acetabular coverage. Labra were categorized into three groups depending on the relation between length of the articular sided surface and height of bony attachment. Labra with a height:length ratio of 2 were classified as hypotrophic, with a height:length ratio of 1 as normal and with a ratio of 0.5 as hypertrophic. Labral cross-sectional areas (CSA) were measured on radial magnetic resonance imaging-arthrography slices using the measuring tool of the PACS system of 20 hips with hypotrophic labra (group 1), 20 hips with normal labral appearance (group 2) and 10 hips with hypertrophic labra (group 3). These values were then analyzed against following parameters: neck-shaft-angle (NSA), lateral center-edge angle (LCE), acetabular index (AI), femoral extrusion index (FEI) and acetabular retroversion index (ARI). Analyses of variance were used to determine differences in mean values between the three groups. Mean labral CSA differed significantly between all groups (group 1: 12.1 ± 2.9 mm(2); group 2: 25.2 ± 6.2 mm(2); group 3: 41.1 ± 12.3 mm(2); P < 0.001). NSA, LCE, AI and FEI all showed a significant difference between group 3 and 1 or 2. The ARI showed no difference between groups. Stepwise linear regression analyses showed a significant correlation between LCE angle and labral CSA with a corrected R (2)-value of 0.301. Labral CSA correlates with the LCE. No statistically significant difference between groups 1 and 2 concerning the LCE, AI or FEI could be identified. Nevertheless, group 1 had the highest mean coverage of all groups, hips with hypertrophic

  16. Is labral hypotrophy correlated with increased acetabular depth?

    PubMed Central

    Toft, Felix; Anliker, Elmar; Beck, Martin

    2015-01-01

    Labral hypertrophy is a distinct feature in hip dysplasia. Occasionally, very small, hypotrophic labra are observed. However, there is no literature concerning this pathology. We investigated if the size of the labrum correlated with any radiologic parameters reflecting the amount of acetabular coverage. It was hypothezised that there is a negative correlation between labrum size and acetabular coverage. Labra were categorized into three groups depending on the relation between length of the articular sided surface and height of bony attachment. Labra with a height:length ratio of 2 were classified as hypotrophic, with a height:length ratio of 1 as normal and with a ratio of 0.5 as hypertrophic. Labral cross-sectional areas (CSA) were measured on radial magnetic resonance imaging-arthrography slices using the measuring tool of the PACS system of 20 hips with hypotrophic labra (group 1), 20 hips with normal labral appearance (group 2) and 10 hips with hypertrophic labra (group 3). These values were then analyzed against following parameters: neck-shaft-angle (NSA), lateral center-edge angle (LCE), acetabular index (AI), femoral extrusion index (FEI) and acetabular retroversion index (ARI). Analyses of variance were used to determine differences in mean values between the three groups. Mean labral CSA differed significantly between all groups (group 1: 12.1 ± 2.9 mm2; group 2: 25.2 ± 6.2 mm2; group 3: 41.1 ± 12.3 mm2; P < 0.001). NSA, LCE, AI and FEI all showed a significant difference between group 3 and 1 or 2. The ARI showed no difference between groups. Stepwise linear regression analyses showed a significant correlation between LCE angle and labral CSA with a corrected R2-value of 0.301. Labral CSA correlates with the LCE. No statistically significant difference between groups 1 and 2 concerning the LCE, AI or FEI could be identified. Nevertheless, group 1 had the highest mean coverage of all groups, hips with hypertrophic labra

  17. Nose fracture

    MedlinePlus

    Fracture of the nose; Broken nose; Nasal fracture; Nasal bone fracture; Nasal septal fracture ... A fractured nose is the most common fracture of the face. It ... with other fractures of the face. Sometimes a blunt injury can ...

  18. Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth

    PubMed Central

    Bechara, B; McMahan, C A; Noujeim, M; Faddoul, T; Moore, W S; Teixeira, F B; Geha, H

    2013-01-01

    Objectives: Two-dimensional intraoral radiography is the most common tool for diagnosing root fractures (RFs). Cone beam CT (CBCT) is widely used to depict RFs in endodontically treated teeth. Beam hardening and other artefacts caused by gutta percha may result in an incorrect diagnosis when using CBCT only. A comparison of two CBCT machines with photostimulated phosphor (PSP) plate images enhanced with the equalization tool was carried out to detect RFs in endodontically treated teeth. Methods: 66 roots were collected, decoronated and treated endodontically using the same technique with gutta percha. 33 of these roots were randomly selected and fractured; the 2 root fragments were glued together with 1 layer of methyl methacrylate and placed randomly in 8 prepared beef rib fragments. Large fields of view (FOVs) were acquired with one CBCT unit and small FOVs with the second CBCT unit. Periapical radiographs (using intraoral PSP plates) were also acquired. A contrast enhancement tool was used when evaluating the PSP plate images. Results: Small FOV images had significantly higher accuracy (area under the receiver operating characteristic curve) and sensitivity in detecting RFs than PSP plates and large FOV images. The specificity of the enhanced PSP images was higher than, although not significantly higher than, the small FOV images and was significantly higher than the large FOV images. Conclusions: CBCT small FOVs should be acquired for depicting RFs of endodontically treated teeth. Images obtained using PSP plates had the lowest rate of false-positive results and their use can save the patient a radiation dose. PMID:23625067

  19. Changes in the radiological measurements of the tibiofibular syndesmal area in patients with Weber C ankle fractures who were treated with open reduction, internal fixation, and transyndesmal screw.

    PubMed

    Jasqui-Remba, S; Torres-Gómez, A; Salas-Morales, G A; Hernández-Martínez, A

    2015-01-01

    The tibiofibular syndesmosis provides stability to the ankle mortise. The ankle syndesmosis is compromised in all Weber C type injuries. The radiographic method described by Merle DAubigné considers the bony relationships as a measure of syndesmotic widening. We sought to investigate whether the patients with a C type ankle fracture treated with ORIF and placement of a transyndesmal screw have an increment of the tibiofibular space and decrease of the tibiofibular overlap after the transyndesmal screw is removed. Our sample included 52 patients with Weber C ankle fractures treated by ORIF and transyndesmal screw at a level II trauma center. We measured the tibiofibular clear space and tibiofibular overlap in each phase of the treatment. The transyndesmal screw was removed at day 55.56 (± 21.83). We found an increase of the tibiofibular overlap of 0.20 mm (± 2.29, p = 0.532); and 0.21 mm (± 0.97, p = 0.146) in the tibiofibular clear space. The changes of 2.38% in the tibiofibular overlap and 5.29% in the tibiofibular clear space between the postoperative and post-removal periods were not statistically significant. After removal of the syndesmal screw, there is a slight radiographic broadening of the syndesmosis; however, it is small and statistically not significant. PMID:27403518

  20. Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures

    PubMed Central

    Zhou, Kai-Hua; Luo, Cong-Feng; Chen, Nong; Hu, Cheng-Fang; Pan, Fu-Gen

    2016-01-01

    Background: The incidence of pelvic fractures in trauma patients is reported to be 3–8.2%, with roughly half of these fractures being caused by high energy injuries with a potential for catastrophic hemorrhage and death. Indications for internal fixation of anterior pelvic ring are controversial. Because of fears of disturbing the pelvic hematoma and causing additional hemorrhage, open reduction and internal fixation of pelvic ring disruption is routinely delayed. In contrast to conventional surgery, percutaneous screw fixation is gaining popularity in the treatment of pelvic and acetabular fractures mainly because of minimal soft tissue damage, less operative blood loss, early surgical intervention and comfortable mobilization of the patient. Fluoro-navigation is a new surgical technique in orthopedic trauma surgery. This study is to investigate clinical results of fluoro-navigation surgery in anterior pelvic ring fractures. Materials and Methods: From January 2006 to October 2011, 23 patients with anterior pelvic ring fractures were treated with percutaneous cannulated screw under fluoro-navigation. There were 14 men and 9 women, with a mean age of 40.1 years (range 25–55). According to the AO and Orthopedic Trauma Association classification, there were seven A 2.1, two A 2.2, one A 2.3, six B 1.2, one B 2.1: 1, one B 2.2, one C 1.2, two C 1.3 and two C 2.3 types of fractures. Amongst these patients, 13 had posterior pelvic ring injuries, 8 had other injuries including urethral, lumbar vertebrae fractures and femoral fractures. All patients were operated when their general condition stabilized after emergency management. The mean time from injury to percutaneous screw fixation of the anterior pelvic ring fracture was 12 days (3–15 days). All the anterior ring fractures were fixed with cannulated screws by two senior surgeons. They were familiar with the navigation system and had gained much experience in the computer-assisted percutaneous placement of

  1. Balance in single-limb stance after surgically treated ankle fractures: a 14-month follow-up

    PubMed Central

    Nilsson, Gertrud; Ageberg, Eva; Ekdahl, Charlotte; Eneroth, Magnus

    2006-01-01

    Background The maintenance of postural control is fundamental for different types of physical activity. This can be measured by having subjects stand on one leg on a force plate. Many studies assessing standing balance have previously been carried out in patients with ankle ligament injuries but not in patients with ankle fractures. The aim of this study was to evaluate whether patients operated on because of an ankle fracture had impaired postural control compared to an uninjured age- and gender-matched control group. Methods Fifty-four individuals (patients) operated on because of an ankle fracture were examined 14 months postoperatively. Muscle strength, ankle mobility, and single-limb stance on a force-platform were measured. Average speed of centre of pressure movements and number of movements exceeding 10 mm from the mean value of centre of pressure were registered in the frontal and sagittal planes on a force-platform. Fifty-four age- and gender-matched uninjured individuals (controls) were examined in the single-limb stance test only. The paired Student t-test was used for comparisons between patients' injured and uninjured legs and between side-matched legs within the controls. The independent Student t-test was used for comparisons between patients and controls. The Chi-square test, and when applicable, Fisher's exact test were used for comparisons between groups. Multiple logistic regression was performed to identify factors associated with belonging to the group unable to complete the single-limb stance test on the force-platform. Results Fourteen of the 54 patients (26%) did not manage to complete the single-limb stance test on the force-platform, whereas all controls managed this (p < 0.001). Age over 45 years was the only factor significantly associated with not managing the test. When not adjusted for age, decreased strength in the ankle plantar flexors and dorsiflexors was significantly associated with not managing the test. In the 40 patients who

  2. An extended posterior approach to the hip and pelvis for complex acetabular reconstruction that preserves the gluteal muscles and their neurovascular supply.

    PubMed

    Solomon, L B; Hofstaetter, J G; Bolt, M J; Howie, D W

    2014-01-01

    We investigated the detailed anatomy of the gluteus maximus, gluteus medius and gluteus minimus and their neurovascular supply in 22 hips in 11 embalmed adult Caucasian human cadavers. This led to the development of a surgical technique for an extended posterior approach to the hip and pelvis that exposes the supra-acetabular ilium and preserves the glutei during revision hip surgery. Proximal to distal mobilisation of the gluteus medius from the posterior gluteal line permits exposure and mobilisation of the superior gluteal neurovascular bundle between the sciatic notch and the entrance to the gluteus medius, enabling a wider exposure of the supra-acetabular ilium. This technique was subsequently used in nine patients undergoing revision total hip replacement involving the reconstruction of nine Paprosky 3B acetabular defects, five of which had pelvic discontinuity. Intra-operative electromyography showed that the innervation of the gluteal muscles was not affected by surgery. Clinical follow-up demonstrated good hip abduction function in all patients. These results were compared with those of a matched cohort treated through a Kocher-Langenbeck approach. Our modified approach maximises the exposure of the ilium above the sciatic notch while protecting the gluteal muscles and their neurovascular bundle. PMID:24395310

  3. Role of the Acetabular Labrum in Load Support Across the Hip Joint

    PubMed Central

    Henak, Corinne R.; Ellis, Benjamin J.; Harris, Michael D.; Anderson, Andrew E.; Peters, Christopher L.; Weiss, Jeffrey A.

    2011-01-01

    The relatively high incidence of labral tears among patients presenting with hip pain suggests that the acetabular labrum is often subjected to injurious loading in vivo. However, it is unclear whether the labrum participates in load transfer across the joint during activities of daily living. This study examined the role of the acetabular labrum in load transfer for hips with normal acetabular geometry and acetabular dysplasia using subject-specific finite element analysis. Models were generated from volumetric CT data and analyzed with and without the labrum during activities of daily living. The labrum in the dysplastic model supported 4-11% of the total load transferred across the joint, while the labrum in the normal model supported only 1-2% of the total load. Despite the increased load transferred to the acetabular cartilage in simulations without the labrum, there were minimal differences in cartilage contact stresses. This was because the load supported by the cartilage correlated to the cartilage contact area. A higher percentage of load was transferred to the labrum in the dysplastic model because the femoral head achieved equilibrium near the lateral edge of the acetabulum. The results of this study suggest that the labrum plays a larger role in load transfer and joint stability in hips with acetabular dysplasia than in hips with normal acetabular geometry. PMID:21757198

  4. Increased risk of revision of acetabular cups coated with hydroxyapatite

    PubMed Central

    Lazarinis, Stergios; Kärrholm, Johan

    2010-01-01

    Background Hydroxyapatite (HA) is the main inorganic component of bone, and HA coating is widely used on acetabular cups in hip arthroplasty. It has been suggested that this surface finish improves cup survival. Methods All patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2007 with an uncemented acetabular implant that was available either with or without HA coating were identified. 8,043 total hip arthroplasties (THAs) with the most common cup types (Harris-Galante, Romanus, and Trilogy) were investigated. A Cox regression model including type of coating, age, sex, primary diagnosis, cup type, and type of stem fixation was used to calculate adjusted risk ratios (RRs) for the risk of revision. Results HA coating was a risk factor for cup revision due to aseptic loosening (adjusted RR 1.7; 95% CI: 1.3–2). Age at primary arthroplasty of < 50 years, a diagnosis of pediatric hip disease, the use of a cemented stem, and the Romanus and Harris-Galante cup types were also associated with statistically significantly increased risk of cup revision due to aseptic loosening. Interpretation Our findings question the routine use of HA-coated cups in primary total hip arthroplasty. With some designs, this practice may even increase the risk of loosening—resulting in revision surgery. PMID:19968603

  5. Biomechanical Evaluation of a Mandibular Spanning Plate Technique Compared to Standard Plating Techniques to Treat Mandibular Symphyseal Fractures

    PubMed Central

    Richardson, Matthew; Hayes, Jonathan; Jordan, J. Randall; Puckett, Aaron; Fort, Matthew

    2015-01-01

    Purpose. The purpose of this study is to compare the biomechanical behavior of the spanning reconstruction plate compared to standard plating techniques for mandibular symphyseal fractures. Materials and Methods. Twenty-five human mandible replicas were used. Five unaltered synthetic mandibles were used as controls. Four experimental groups of different reconstruction techniques with five in each group were tested. Each synthetic mandible was subjected to a splaying force applied to the mandibular angle by a mechanical testing unit until the construct failed. Peak load and stiffness were recorded. The peak load and stiffness were analyzed using ANOVA and the Tukey test at a confidence level of 95% (P < 0.05). Results. The two parallel plates' group showed statistically significant lower values for peak load and stiffness compared to all other groups. No statistically significant difference was found for peak load and stiffness between the control (C) group, lag screw (LS) group, and the spanning plate (SP1) group. Conclusions. The spanning reconstruction plate technique for fixation of mandibular symphyseal fractures showed similar mechanical behavior to the lag screw technique when subjected to splaying forces between the mandibular gonial angles and may be considered as an alternative technique when increased reconstructive strength is needed. PMID:26649332

  6. Assessment of the influence of Laser phototherapy on the bone repair process of complete fractures in tibiae of rabbits stabilized with semi-rigid internal fixation treated with or without MTA graft: a histological study

    NASA Astrophysics Data System (ADS)

    Soares, Luiz G. P.; Silva, Aline C. P.; Silva, Anna Paula L. T.; Neves, Bruno Luiz R. C.; Santos, Nicole R. S.; dos Santos, Jean N.; Pinheiro, Antonio L. B.

    2016-03-01

    Beside biomaterials, Laser phototherapy has shown positive effects as auxiliary therapy in bone repair process, especially when involving large bone losses. The aim of this histological study was to evaluate, by light microscopy, the influence of laser phototherapy on the repair of complete tibial fractures in rabbits treated or not with semi-rigid internal fixation and Mineral Trioxide Aggregate - MTA graft. Twelve Rabbits were randomly divided into four groups with three animals each. After general anesthesia, complete fractures were created in one tibia with a carborundum disk. All animals (groups I-IV) had the fracture stabilized with semi-rigid fixation (wire osteosynthesis - WO). Group I was routinely fixed with WO; groups II and IV fracture was filled by blood clot and MTA implant. In Groups III and IV fracture was filled by blood clot and further irradiated with laser (λ780 nm, 70 mW, CW, Φ = 0.04 cm2, 20.4 J/cm2, per session, t = 300s, 142.8 J/cm2 per treatment). The phototherapy protocol was applied immediately after the surgery and repeated each 48 hours during 15 days. Animal death occurred on the 30th postoperative day. After removal of the specimens, the samples were routinely processed, stained with HE and evaluated by light microscopy. Histologically, the group treated with MTA graft and irradiated with laser showed the fracture filled by a more organized and mature trabecular bone, when compared with all other groups. From the results of the present study, it may be concluded that the association of Laser phototherapy + MTA graft in fractures treated with WO improved bone repair when compared with fractures treated only with WO.

  7. Relationship between the functional outcomes and radiological results of conservatively treated displaced proximal humerus fractures in the elderly: A prospective study

    PubMed Central

    Canbora, Mehmet Kerem; Kose, Ozkan; Polat, Atilla; Konukoglu, Levent; Gorgec, Mucahit

    2013-01-01

    Purpose: The purpose of this prospective study is to investigate the relationship between the functional outcome and the radiographic results of conservatively treated two-, three- and four-part proximal humeral fractures in patients aged over 65 years. Materials and Methods: The study comprised 29 prospectively followed cases aged over 65 years who presented with displaced proximal humerus fracture between 2009 and 2011. The fractures were classified according to the Neer classification and all met the displacement criteria described by Neer. Standard physical therapy program was applied. Patients were evaluated clinically using Constant shoulder score, quick form of disabilities of arm, shoulder and hand score and visual analog scale. At the final follow-up, humeral head position in the coronal plane was assessed with neck-shaft angle. Any complication was recorded during the treatment period. Correlation between the functional outcomes and final radiologic results were statistically analyzed. Results: Data were analyzed from 29 cases (21 female, 8 male) with a mean age was 78 ± 8.6 years (range 65-93 years). The mean follow-up period was 18.2 ± 4.07 months (range 12-26 months). Functional results were significantly related with initial fragmentation. However, there was no correlation between the functional outcomes and the final geometry of the humeral head. Despite the union occurred with deformity, the functional outcome were satisfactory. Conclusion: The results of this study show that initial fragmentation has a negative effect on the functional results. However, the changed position of the humeral head on coronal plane does not affect the final functional results. PMID:24167402

  8. Nose fracture

    MedlinePlus

    Fracture of the nose; Broken nose; Nasal fracture; Nasal bone fracture; Nasal septal fracture ... A fractured nose is the most common fracture of the face. It usually occurs after an injury and often occurs with ...

  9. Early Treatment of Acute Complex Regional Pain Syndrome after Fracture or Injury with Prednisone: Why Is There a Failure to Treat? A Case Series

    PubMed Central

    2016-01-01

    Background. Complex regional pain syndrome (CRPS) after fracture is a cause of pain, dysfunction, and potentially permanent disability. The evidence for treatment with oral corticosteroids is growing and supported by several international guidelines; however, treatment is not widely offered. Objective. Rapid recognition and treatment of complex regional pain in the upper extremity after acute injury as a disease modifying and potentially curative treatment. Methods. The present study was a case series involving three patients who developed CRPS after a trauma to the neck and/or upper limb. Patients were screened by clinical examination and bone scan and met the Budapest criteria. Results. Resolution of pain, swelling, and disability in all three patients. Discussion. There is increasing support, based on the existing evidence and clinical outcomes, for the use of prednisone to treat the acute phase of CRPS and as a promising treatment to halt the progression of the phenomenon and potentially cure the condition; however, widespread use of prednisone likely remains low, potentially resulting in long-term pain, joint contracture, and disability. A large-scale randomized control trial has not been performed. Conclusion. Corticosteroids can be an effective treatment option for CRPS after fracture. PMID:27445622

  10. Skull fracture

    MedlinePlus

    Basilar skull fracture; Depressed skull fracture; Linear skull fracture ... Skull fractures may occur with head injuries . The skull provides good protection for the brain. However, a severe impact ...

  11. Traumatic medial displacement of Rotalok uncemented acetabular component. A case report.

    PubMed

    Charnley, G J; Ridge, J; Ribbans, W J

    1994-04-01

    The failure of uncemented acetabular components has been described in association with component wear, disassembly, and proximal migration. The authors report a case of medial displacement following minor trauma some 18 months after surgery. The component involved differs in design from both press-fit, porous-coated or screw-in, fully threaded acetabular cups. The authors suggest that additional screws should be inserted to enhance long-term stability. PMID:8014654

  12. Rapid resolution of femoral head osteonecrosis after rotational acetabular osteotomy.

    PubMed

    Nozawa, Masahiko; Matsuda, Keiji; Maezawa, Katsuhiko; Kim, Sungon; Maeda, Kouichi; Ikegami, Takashi; Kubota, Reiko; Hayashi, Kentaro; Nagayama, Masataka; Kaneko, Haruka

    2008-12-01

    The natural history of osteonecrosis of the femoral head is generally thought to be one of progressive deterioration if no intervention is undertaken. However, it is unknown whether surgical intervention is beneficial for patients with a small region of osteonecrosis. We observed rapid improvement of MRI findings after rotational acetabular osteotomy (RAO) was performed in a young patient with osteonecrosis of the femoral head. The band-like low signal area on T2-weighted images almost resolved by six months after surgery. He returned to work as an electrician by six months after surgery. Early surgical intervention such as RAO that alters the mechanical force acting on the necrotic region of the femoral head may accelerate the recovery of osteonecrosis and the improvement of symptoms. PMID:19384490

  13. Failure analysis of retrieved PE-UHMW acetabular liners.

    PubMed

    Laska, Anna; Archodoulaki, Vasiliki-Maria; Duscher, Bernadette

    2016-08-01

    Ultra-high molecular weight polyethylene (PE-UHMW) acetabular liners have a limited lifespan in a patient's body. There are many factors affecting the performance of the implant and furthermore the properties of the polymeric material are changing after implantation. In this work material changes according to structure and morphology and their implication on mechanical properties are in focus. The physical and mechanical properties of ten crosslinked (xL) PE-UHMW and nine conventional (conv) gamma-sterilized PE-UHMW hip components, used as sliding surface in total hip joint replacement, with different in-vivo times are compared. The evaluation of the retrieved acetabular liners is performed in view of crosslinking and conventional gamma-sterilization but also in terms of the influence of gender concerning alteration in properties. The oxidative degradation in the PE-UHMW is investigated by means of Fourier Transformed Infrared Spectroscopy (FTIR). The characterization of the morphology is carried out via differential scanning calorimetry (DSC). A depth profile of the micro-hardness and elastic modulus is taken over the cross-section of the components in order to find the influence of chemical constitution and morphology on the micro-mechanical properties. It could be shown that crosslinking and oxidative degradation influence the degree of crystallinity of the polymer. Oxidation occurs for both types of the material due to in-vivo time. Higher degree of crystallinity can be correlated to higher hardness and indentation modulus. No unequivocal superiority of crosslinked over conventional liners can be observed. The influence of sex concerning alteration of the evaluated properties matters but need to be further investigated. PMID:26849029

  14. Hydroxyapatite coating of an acetabular prosthesis. Effect on stability.

    PubMed

    Moilanen, T; Stocks, G W; Freeman, M A; Scott, G; Goodier, W D; Evans, S J

    1996-03-01

    We report the radiological and clinical outcome of a press-fit (SLF) acetabular component at two to three years in two groups of patients having primary total hip replacement. In 69 the implant was coated with hydroxyapatite (HA) and in 40 it was uncoated. The stability of the cup was assessed by measurement of proximal migration and change in the angle of inclination. The clinical results in the two groups did not differ significantly, and the mean proximal linear wear was similar in both. Fewer radiolucent lines (RLLs) were seen on the radiographs of cups coated with HA. The mean proximal migration was studied by calculating regression lines for each patient using migration measurements: for the SLF+HA group the mean slope was 0.06 mm/year and for the SLF-HA group 0.20 mm/year (p = 0.22). The change in the angle of inclination during follow-up was also consistently smaller in HA-coated cups. Using regression methods the SLF+HA group had a mean slope of 0.08 degrees/year and the SLF-HA group 0.44 degrees/year and the SLF-HA group 0.44 degrees/year (p = 0.023). Partial HA coating appeared to have no effect on the clinical outcome or on the rate of wear of polyethylene, but there was a trend towards a reduced rate of proximal migration, and a significant reduction in rotational migration and the number of radiolucent lines. This suggests that HA coating enhances the stability of this acetabular component. PMID:8666624

  15. Mechanical resistance evaluation of a novel anatomical short glass fiber reinforced post in artificial endodontically treated premolar under rotational/lateral fracture fatigue testing.

    PubMed

    Wang, Hsuan-Wen; Chang, Yen-Hsiang; Lin, Chun-Li

    2016-01-01

    This study develops a novel anatomical short glass fiber reinforced (anatomical SGFR) post and evaluates the mechanical performance in artificial endodontically treated premolars. An anatomical SGFR fiber post with an oval shape and slot/notch designs was manufactured using an injection-molding machine. The three-point bending test and crown/core restorations using the anatomical SGFR and commercial cylindrical fiber posts under fatigue test were executed to understand the mechanical resistances. The results showed that static and dynamic rotational resistance were found significantly higher in the anatomical SGFR fiber post than in the commercial post. The endurance limitations at 1.2×10(6) cycles were 66.81 and 64.77 N for the anatomical SGFR and commercial fiber posts, respectively. The anatomical SGFR fiber post presented acceptable value of flexural strength and modulus, better fit adaption in the root canal resist torque more efficiency but was not a key issue in the lateral fracture resistance in an endodontically treated premolar. PMID:27041013

  16. Quantitative Computerized Assessment of the Degree of Acetabular Bone Deficiency: Total radial Acetabular Bone Loss (TrABL).

    PubMed

    Gelaude, Frederik; Clijmans, Tim; Delport, Hendrik

    2011-01-01

    A novel quantitative, computerized, and, therefore, highly objective method is presented to assess the degree of total radical acetabular bone loss. The method, which is abbreviated to "TrABL", makes use of advanced 3D CT-based image processing and effective 3D anatomical reconstruction methodology. The output data consist of a ratio and a graph, which can both be used for direct comparison between specimens. A first dataset of twelve highly deficient hemipelves, mainly Paprosky types IIIB, is used as illustration. Although generalization of the findings will require further investigation on a larger population, it can be assumed that the presented method has the potential to facilitate the preoperative use of existing classifications and related decision schemes for treatment selection in complex revision cases. PMID:22013539

  17. Comparative evaluation of the effect of different crown ferrule designs on the fracture resistance of endodontically treated mandibular premolars restored with fiber posts, composite cores, and crowns: An ex-vivo study

    PubMed Central

    Dua, Nikita; Kumar, Bhupendra; Arunagiri, D.; Iqbal, Mohammad; Pushpa, S.; Hussain, Juhi

    2016-01-01

    Introduction: In cases of severe hard tissue loss, 2 mm circumferential ferrule is difficult to achieve which leads to incorporation of different ferrule designs. Aim: To compare and evaluate the effect of different crown ferrule designs on the fracture resistance of mandibular premolars restored with fiber posts, composite cores, and crowns. Materials and Methods: Fifty freshly extracted mandibular premolars were endodontically treated and divided into five groups: Group I - 2 mm circumferential ferrule above the cementoenamel junction (CEJ); Group II - 2 mm ferrule on the facial aspect above CEJ; Group III - 2 mm ferrule on the lingual aspect above CEJ; Group IV - 2 mm ferrule on the facial and lingual aspects above CEJ with interproximal concavities, and Group V - no ferrule (control group) and were later restored with fiber posts, composite cores, and crowns. Specimens were mounted on a universal testing machine, and compressive load was applied at a crosshead speed of 1 mm/min until fracture occurred. Results: The results showed that circumferential ferrule produced the highest mean fracture resistance and the least fracture resistance was found in the control group. Conclusion: Circumferential ferrule increases the fracture resistance of endodontically treated teeth restored with bonded post, core, and crown. PMID:27217642

  18. Cement as a locking mechanism for screw heads in acetabular revision shells - a biomechanical analysis.

    PubMed

    Laflamme, G Y; Alami, G B; Zhim, F

    2008-01-01

    In acetabular revisions, polyethylene (PE) liners are often cemented into metal shells on top of acetabular screw heads. This study investigates the possibility of using this technique to obtain fixed-angle acetabular screws Eth a concept that has not yet been reported in the literature. Two groups of screws (n=8) were inserted into Trabecular Metal revision shells (Zimmer), into which PE liners were then cemented. Screws in Group 1, inserted in the shell's pre-fabricated holes, were countersunk, whereas screws in Group 2 were inserted in custom-drilled holes that make their heads protrude into, and interdigitate with, the overlying cement mantle. Perpendicular loading was then applied to the screw shafts both statically to failure and cyclically. A greater stiffness was observed for the protruding screws upon static loading; and while the countersunk screws all failed at the screw-cement junction (53.44 + or - 8.33 N), the protruding screws all failed at the screw shaft (1049.79 + or - 32.12 N) a 20-fold difference (p< 0.05). Under cyclic loading, only the protruding screw head specimen did not fail, undergoing an overall displacement within the limits of osseointegration.These results support the hypothesis that the protrusion of an acetabular screw head into an overlying cement mantle significantly increases its angular stability. Provided other variables are favorable, this locking effect may increase the initial stability of the whole implant, thus improving the ultimate success of complex acetabular revisions. PMID:18645971

  19. Morphometric assessment of the canine hip joint using the acetabular angle of retrotorsion.

    PubMed

    Doskarova, B; Kyllar, M; Paral, V

    2010-01-01

    Morphometric assessment of the canine hip joint using acetabular angle of retrotorsion was used in this study. The aim of our study was to compare the acetabular angle of retrotorsion (AAR) with values of the Norberg angle (NA) and the hip score (HS) in the Leonberger dog breed and to determine the cut-off point of AAR that distinguish between normal and dysplastic hip status on the basis of Fédération Cynologique Internationale (FCI) hip evaluation. Retrospective analysis of NA and AAR was measured from standard ventrodorsal pelvic radiographs with extended femurs in 387 Leonberger dogs (141 males and 246 females) from 18 to 63 months of age, which were then divided into five age-groups. Through analysis of these radiographs, it was determined that the cut-off point for NA was 105°, AAR was 15°, and the acetabular angle of retrotorsion was positively correlated with Norberg angle and negatively correlated with hip score. The results of our study indicate that the acetabular angle of retrotorsion may represent a reliable morphometric assessment tool in evaluating acetabular cup conformation, and values of AAR may help to assess the FCI grade of canine hip dysplasia. PMID:20740259

  20. Acetabular rim and surface segmentation for hip surgery planning and dysplasia evaluation

    NASA Astrophysics Data System (ADS)

    Tan, Sovira; Yao, Jianhua; Yao, Lawrence; Summers, Ronald M.; Ward, Michael M.

    2008-03-01

    Knowledge of the acetabular rim and surface can be invaluable for hip surgery planning and dysplasia evaluation. The acetabular rim can also be used as a landmark for registration purposes. At the present time acetabular features are mostly extracted manually at great cost of time and human labor. Using a recent level set algorithm that can evolve on the surface of a 3D object represented by a triangular mesh we automatically extracted rims and surfaces of acetabulae. The level set is guided by curvature features on the mesh. It can segment portions of a surface that are bounded by a line of extremal curvature (ridgeline or crestline). The rim of the acetabulum is such an extremal curvature line. Our material consists of eight hemi-pelvis surfaces. The algorithm is initiated by putting a small circle (level set seed) at the center of the acetabular surface. Because this surface distinctively has the form of a cup we were able to use the Shape Index feature to automatically extract an approximate center. The circle then expands and deforms so as to take the shape of the acetabular rim. The results were visually inspected. Only minor errors were detected. The algorithm also proved to be robust. Seed placement was satisfactory for the eight hemi-pelvis surfaces without changing any parameters. For the level set evolution we were able to use a single set of parameters for seven out of eight surfaces.

  1. Research synthesis of recommended acetabular cup orientations for total hip arthroplasty.

    PubMed

    Harrison, Claire L; Thomson, Avril I; Cutts, Steven; Rowe, Philip J; Riches, Philip E

    2014-02-01

    Total hip arthroplasty (THA) is regarded as one of the most successful surgical procedures of modern times yet continues to be associated with a small but significant complication rate. Many early failures may be associated with poor component positioning with, in particular, acetabular component orientation dependent on the subjective judgement of the surgeon. In this paper, we compare the manufacturers' instructions on acetabular cup orientation with the literature-based recommended safety zones and surgical technique, by transforming them onto a single, clinically-relevant framework in which the different reference systems, safety guidelines and current instrumentation surgical techniques can be evaluated. The observed limited consensus between results reflects ongoing uncertainty regarding the optimum acetabular component positioning. As malpositioning of the acetabular cup increases the risk of revision surgery, any ambiguity over the correct position can have a causal effect. Our analysis highlights the need for a surgical reference system which can be used to describe the position of the acetabular cup intra-operatively. PMID:23958234

  2. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... uncemented acetabular component, prosthesis. 888.3330 Section 888.3330 Food and Drugs FOOD AND DRUG..., prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The...

  3. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... uncemented acetabular component, prosthesis. 888.3330 Section 888.3330 Food and Drugs FOOD AND DRUG..., prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The...

  4. Quantification of clearance and creep in acetabular wear measurements

    PubMed Central

    Gregory, Thomas; Vandenbussche, Eric

    2016-01-01

    Background This study aimed to measure femoral head penetration before occurrence of real wear, and to quantify the portions attributable respectively to clearance and plastic deformations in various acetabular designs. Methods We analyzed CT scans from 15 patients at ‘day five’ after total hip arthroplasty (THA). All patients received Exafit® femoral stems and 28 mm heads: 5 patients had cemented Durasul® all-PE cups, 5 patients had un-cemented Allofit® metal-backed cups, and 5 patients had un-cemented Stafit® dual-mobility cups. We also analyzed CT scans of samples of the three head-cup combinations to compare in vivo and in vitro measurements. Results The mean femoral head penetration measured on ‘day five’ was lower for all-PE cups (0.196 mm) than for metal-backed cups (0.551 mm) and dual-mobility cups (0.634 mm). Conclusions The present study indicates that isolated measurements of femoral head penetration include 0.15–0.46 mm of radial clearance and 0.05–0.27 mm of creep, and confirms that the majority of so-called bedding-in observed in the first post-operative months is not entirely due to wear. PMID:27162781

  5. The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation.

    PubMed

    Phillips, A T M; Pankaj; Usmani, A S; Howie, C R

    2004-01-01

    The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup. PMID:15376726

  6. Fracture tooth fragment reattachment

    PubMed Central

    Maitin, Nitin; Maitin, Shipra Nangalia; Rastogi, Khushboo; Bhushan, Rajarshi

    2013-01-01

    Coronal fractures of the anterior teeth are a common form of dental trauma and its sequelae may impair the establishment and accomplishment of an adequate treatment plan. Among the various treatment options, reattachment of a crown fragment is a conservative treatment that should be considered for crown fractures of anterior teeth. This clinical case reports the management of two coronal tooth fracture cases that were successfully treated using tooth fragment reattachment using glass-fibre-reinforced composite post. PMID:23853012

  7. Midterm survivorship of a press-fit, plasma-sprayed, tri-spike acetabular component.

    PubMed

    Klaassen, Mark A; Martínez-Villalobos, Mario; Pietrzak, William S; Mangino, Gerardo P; Guzman, Delfino Carranza

    2009-04-01

    Press-fit acetabular cups without screw holes can limit migration of particulate wear debris and reduce risk of acetabular osteolysis and device loosening. The Tri-Spike cup (Biomet, Inc, Warsaw, Ind) includes a titanium alloy plasma spray porous surface and does not require screw fixation. We retrospectively examined the incidence of cup loosening and acetabular osteolysis after implantation of 45 cups (44 patients) with mean follow-up of 7.3 years (range, 4-9 years). Only one patient (one cup) had evidence of less than 1 mm of retroacetabular radiolucency at 3 years (nonprogressive), which was found to remain firmly fixed during revision of the aseptically loosened femoral component. No cups were removed or revised at latest follow-up. Projected Kaplan-Meier survivorship at 9 years was 100% for cup loosening/revision and 97.8% for radiolucency. PMID:18534453

  8. The results of acetabular impaction grafting in 129 primary cemented total hip arthroplasties.

    PubMed

    Wilson, Matthew J; Whitehouse, Sarah L; Howell, Jonathan R; Hubble, Matthew J W; Timperley, A John; Gie, Graham A

    2013-09-01

    Between 1995 and 2003, 129 cemented primary THAs were performed using full acetabular impaction grafting to reconstruct acetabular deficiencies. These were classified as cavitary in 74 and segmental in 55 hips. Eighty-one patients were reviewed at mean 9.1 (6.2-14.3) years post-operatively. There were seven acetabular component revisions due to aseptic loosening, and a further 11 cases that had migrated >5mm or tilted >5° on radiological review - ten of which reported no symptoms. Kaplan-Meier analysis of revisions for aseptic loosening demonstrates 100% survival at nine years for cavitary defects compared to 82.6% for segmental defects. Our results suggest that the medium-term survival of this technique is excellent when used for purely cavitary defects but less predictable when used with large rim meshes in segmental defects. PMID:23523217

  9. Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum

    PubMed Central

    He, Jiliang; Tan, Guoqing; Zhou, Dongsheng; Sun, Liang; Li, Qinghu; Yang, Yongliang; Liu, Ping

    2016-01-01

    Abstract Percutaneous screw insertion for minimally displaced or reducible acetabular fracture using x-ray fluoroscopy and computer-assisted navigation system has been advocated by some authors. The purpose of this study was to compare intraoperative conditions and clinical results between isocentric C-arm 3-dimensional (Iso-C 3D) fluoroscopy and conventional fluoroscopy for percutaneous retrograde screwing of acetabular anterior column fracture. A prospective cohort study was conducted. A total of 22 patients were assigned to 2 different groups: 10 patients in the Iso-C 3D navigation group and 12 patients in the conventional group. The operative time, fluoroscopic time, time of screw insertion, blood loss, and accuracy were analyzed between the 2 groups. There were significant differences in operative time, screw insertion time, fluoroscopy time, and mean blood loss between the 2 groups. Totally 2 of 12 (16.7%) screws were misplaced in the conventional fluoroscopy group, and all 10 screws were in safe zones in the navigation group. Percutaneous screw fixation using the Iso-C 3D computer-assisted navigation system significantly reduced the intraoperative fluoroscopy time and blood loss in percutaneous screwing for acetabular anterior column fracture. The Iso-C 3D computer-assisted navigation system provided a reliable and effective method for percutaneous screw insertion in acetabular anterior column fractures compared to conventional fluoroscopy. PMID:26765448

  10. Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum: An Observational Study.

    PubMed

    He, Jiliang; Tan, Guoqing; Zhou, Dongsheng; Sun, Liang; Li, Qinghu; Yang, Yongliang; Liu, Ping

    2016-01-01

    Percutaneous screw insertion for minimally displaced or reducible acetabular fracture using x-ray fluoroscopy and computer-assisted navigation system has been advocated by some authors. The purpose of this study was to compare intraoperative conditions and clinical results between isocentric C-arm 3-dimensional (Iso-C 3D) fluoroscopy and conventional fluoroscopy for percutaneous retrograde screwing of acetabular anterior column fracture.A prospective cohort study was conducted. A total of 22 patients were assigned to 2 different groups: 10 patients in the Iso-C 3D navigation group and 12 patients in the conventional group. The operative time, fluoroscopic time, time of screw insertion, blood loss, and accuracy were analyzed between the 2 groups.There were significant differences in operative time, screw insertion time, fluoroscopy time, and mean blood loss between the 2 groups. Totally 2 of 12 (16.7%) screws were misplaced in the conventional fluoroscopy group, and all 10 screws were in safe zones in the navigation group. Percutaneous screw fixation using the Iso-C 3D computer-assisted navigation system significantly reduced the intraoperative fluoroscopy time and blood loss in percutaneous screwing for acetabular anterior column fracture.The Iso-C 3D computer-assisted navigation system provided a reliable and effective method for percutaneous screw insertion in acetabular anterior column fractures compared to conventional fluoroscopy. PMID:26765448

  11. Patient-specific acetabular shape modelling: comparison among sphere, ellipsoid and conchoid parameterisations.

    PubMed

    Cerveri, Pietro; Manzotti, Alfonso; Baroni, Guido

    2014-04-01

    The shape of the human acetabular cup was commonly represented as a hemisphere, but different geometries and patient-specific shapes have been recently proposed in the literature. Our aim was to test the limits of the sphericity assumption by comparing three different parameterisations, namely the sphere, the ellipsoid and the rotational conchoid. Models of hip surfaces, reconstructed from CT scans taken from Caucasian race cadavers and patients, were automatically processed to extract the acetabular surface. Two separate analyses were carried out on the overall acetabular shape, including both the acetabular fossa and the lunate surface (case A) and acetabular cup represented by the lunate surface only (case B). Nonlinear gradient-based and evolutionary computation approaches were implemented for the fitting process. Minor differences from the three idealised geometries were detected (median values of the fitting errors < 1 mm). Nonetheless, the sphere fitting was found to be statistically different from both the ellipsoid (p < 2.50e - 10) and the conchoid (p < 1.07e - 09), whereas no statistical difference was detected between the ellipsoid and the conchoid for case A. Significance of the difference between ellipsoid and sphere (p < 4.55e - 12) and between conchoid and sphere (p < 1.93e - 11) was found for case B as well. Interestingly, for case B statistical difference was detected between the ellipsoid and the conchoid. In conclusion, we synthesise that the morphology of the overall acetabular cup can be parameterised both with an ellipsoid shape and with a conchoid shape as well with superior quality than the simple sphere. Differently, if one considers just the lunate surface, better fitting results are expected when using the ellipsoid. PMID:22789071

  12. Impaction grafted bone chip size effect on initial stability in an acetabular model: Mechanical evaluation

    PubMed Central

    Holton, Colin; Bobak, Peter; Wilcox, Ruth; Jin, Zhongmin

    2013-01-01

    Introduction Acetabular bone defect reconstruction is an increasing problem for surgeons with patients undergoing complex primary or revision total hip replacement surgery. Impaction bone grafting is one technique that has favourable long-term clinical outcome results for patients who undergo this reconstruction method for acetabular bone defects. Creating initial mechanical stability of the impaction bone graft in this technique is known to be the key factor in achieving a favourable implant survival rate. Different sizes of bone chips were used in this technique to investigate if the size of bone chips used affected initial mechanical stability of a reconstructed acetabulum. Methodology Twenty acetabular models were created in total. Five control models were created with a cemented cup in a normal acetabulum. Then five models in three different groups of bone chip size were constructed. The three groups had an acetabular protrusion defect reconstructed using either; 2–4 mm3, 10 mm3 or 20 mm3 bone chip size for impaction grafting reconstruction. The models underwent compression loading up to 9500 N and displacement within the acetabular model was measured indicating the initial mechanical stability. Results This study reveals that, although not statistically significant, the largest (20 mm3) bone chip size grafted models have an inferior maximum stiffness compared to the medium (10 mm3) bone chip size. Interpretations Our study suggests that 10 mm3 size of bone chips provide better initial mechanical stability compared to smaller or larger bone chips. We dismissed the previously held opinion that the biggest practically possible graft is best for acetabular bone graft impaction. PMID:24396238

  13. An assessment of fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in endodontically treated teeth: an in vitro study

    PubMed Central

    Pal, Bhupinder; Pujari, Prashant

    2015-01-01

    Endodontically treated teeth with excessive loss of tooth structure would require to be restored with post and core to enhance the strength and durability of the tooth and to achieve retention for the restoration. The non-metallic posts have a superior aesthetic quality. Various core build-up materials can be used to build-up cores on the posts placed in endodontically treated teeth. These materials would show variation in their bonding with the non-metallic posts thus affecting the strength and resistance to fracture of the remaining tooth structure. Aims. The aim of the study was to assess the fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in extracted endodontically treated teeth. Material and Methods. Forty-five freshly extracted maxillary central incisors of approximately of the same size and shape were selected for the study. They were divided randomly into 3 groups of 15 each, depending on the types of non-metallic posts used. Each group was further divided into 3 groups (A, B and C) of 5 samples each depending on three core build-up material used. Student’s unpaired ‘t’ test was also used to analyse and compare each group with the other groups individually, and decide whether their comparisons were statistically significant. Results. Luxacore showed the highest fracture resistance among the three core build-up materials with all the three posts systems. Ti-core had intermediate values of fracture resistance and Lumiglass had the least values of fracture resistance. PMID:25755926

  14. Stress fractures in athletes.

    PubMed

    Hulkko, A; Orava, S

    1987-06-01

    During the 14-year period of 1971-1985, 368 stress fractures in 324 athletes were treated. The series contained 268 fractures in males and 100 fractures in females; 32 fractures occurred in children (less than 16 years), 117 in adolescents (16-19 years), and 219 in adults. Forty-six fractures were incurred by athletes at an international level, 274 by athletes at a national or district level and 48 by recreational athletes. Of the total cases, 72% occurred to runners and a further 12% to athletes in other sports after running exercises. The distribution of the stress fractures by site was: tibia 182, metatarsal bones 73, fibula 44, big toe sesamoid bones 15, femoral shaft 14, femoral neck 9, tarsal navicular 9, pelvis 7, olecranon 5 and other bones 10. Of the total fractures, 342 were treated conservatively and 26 fractures required surgical treatment. The operative indication was dislocation in 5 cases and delayed union/nonunion in 21 cases. The sites most often affected by delayed union were: anterior midtibia, sesamoid bones of the big toe, base of the fifth metatarsal, olecranon, and tarsal navicular. The athletes at an international level experienced the greatest risk of multiple separate fractures, protracted healing, or fractures requiring surgery. PMID:3623785

  15. The efficacy of the use of IR laser phototherapy associated to biphasic ceramic graft and guided bone regeneration on surgical fractures treated with miniplates: a histological and histomorphometric study on rabbits.

    PubMed

    Pinheiro, Antonio L B; Aciole, Gilberth Tadeu Santos; Ramos, Thais Andrade; Gonzalez, Tayná Assunção; da Silva, Laís Nogueira; Soares, Luiz G Pinheiro; Aciole, Jouber Mateus Santos; dos Santos, Jean Nunes

    2014-01-01

    The aim of the present study was to assess, by light microscopy and histomorphometry, the repair of surgical fractures fixed with internal rigid fixation (IRF) treated or not with IR laser (λ780 nm, 50 mW, 4 × 4 J/cm(2) = 16 J/cm(2), ϕ = 0.5 cm(2), CW) associated or not to the use of hydroxyapatite and guided bone regeneration. Surgical tibial fractures were created under general anesthesia on 15 rabbits that were divided into 5 groups, maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet, and had water ad libidum. The fractures in groups II, III, IV, and V were fixed with miniplates. Animals in groups III and V were grafted with hydroxyapatite and GBR technique used. Animals in groups IV and V were irradiated at every other day during two weeks (4 × 4 J/cm(2), 16 J/cm(2) = 112 J/cm(2)). Observation time was that of 30 days. After animal death, specimens were taken, routinely processed to wax, cut and stained with HA and Sirius red, and used for histological assessment. The results of both analyses showed a better bone repair on all irradiated subjects especially when the biomaterial and GBR were used. In conclusion, the results of the present investigation are important clinically as they are suggestive that the association of hydroxyapatite, and laser light resulted in a positive and significant repair of complete tibial fractures treated with miniplates. PMID:23649614

  16. Evaluation of ranges of motion of a new constrained acetabular prosthesis for canine total hip replacement

    PubMed Central

    2013-01-01

    Background Total hip replacement (THR) is considered to be the most effective treatment option for advanced osteoarthritis of the hip in large breed dogs. However, a proportion of post-THR patients suffer prosthesis dislocation for various reasons, which may be addressed by a constrained acetabular prosthesis design. The study proposed a new THR with constrained acetabular component that aimed to decrease the incidence of postoperative dislocation while maintaining the necessary range of motion (ROM); and, through computer-simulated implantations, evaluated the ROM of the THR with and without malpositioning of the acetabular component. Methods A new THR with a constrained acetabular component that had an inward eccentric lining and a 60° cut-out on the dorsal side was designed, and its computer-aided design models were implanted into the pelvic and femoral models reconstructed from the computed tomography data of six healthy Labrador Retriever dogs. The allowable and functional ROM of the implanted THR were determined via computer simulations. The contact patterns between the bone or the prosthetic components at extreme positions of the THR were analyzed. Influence of malpositioning of the acetabular component on the ROM was assessed. Results The means (SD) of the functional ranges for flexion, extension, adduction, abduction, internal rotation and external rotation were 51.8° (6.6°), 163.3° (7.3°), 33.5° (5.7°), 74.0° (3.7°), 41.5° (8.3°) and 65.2° (9.9°), respectively. Malpositioning of the acetabular component by 20° in one direction was found to reduce ROM in other directions (reducing lateral opening: flexion: 12°, adduction: 20°, internal/external rotations: < 20°; increasing lateral opening: extension and abduction: < 16°; reducing retroversion: extension: < 20°, abduction: 15°, external rotation: < 20°; increasing retroversion: flexion: < 20°, abduction, adduction and internal rotation: 20°). Conclusions From the computer

  17. Acetabular labral tears: focused review of anatomy, diagnosis, and current management.

    PubMed

    Huang, Ronald; Diaz, Claudio; Parvizi, Javad

    2012-05-01

    Acetabular labral tears have become an increasingly common diagnosis with the advancement of imaging techniques and hip arthroscopy. Therefore, understanding the anatomic significance, healing potential, and associated pathologies of labral tears is helpful. Furthermore, recognizing the clinical picture and understanding appropriate imaging techniques, such as magnetic resonance arthrography, are essential to making a correct diagnosis. This article reviews the relevant anatomy, diagnosis, and management of acetabular labral tears for physicians of all specialties who may be involved in the care of patients with labral tears. Short-term results of labral repair have been promising, but further studies are needed to clarify appropriate indications and long-term results of treatment. PMID:22759609

  18. [Bipolar endoprosthesis in fractures of the femoral neck. Apropos of 201 cases, 116 after a 6-year follow-up].

    PubMed

    Lortat-Jacob, A; Videcoq, P; Hardy, P; Fontes, D; de Somer, B; Benoit, J

    1992-01-01

    We report our experience with 201 SEM bipolar prostheses used to treat femoral neck fractures in patients with a mean age of 70 years and a mean follow-up of 57 months (median 75 months). Clinical outcome was favorable with 94 per cent satisfactory results (very good and good). Femoral complications requiring reoperation (conversion to total hip replacement) occurred in 2.2 per cent of cases. Among the 163 patients for whom roentgenographic data were available, 5 (3.6 per cent) developed evidence of acetabular wear but remained symptom-free and did not require reoperation. As compared with Moore's prosthesis, the SEM bipolar prosthesis seems to provide substantially better clinical and roentgenographic results. For the treatment of femoral neck fractures, total hip replacement seems to provide results comparable to those reported here but requires a more sophisticated operative technique and carries a greater risk of subsequent dislocation. Two factors prevent the widespread use of the bipolar prosthesis at present: the need for femoral grouting which carries a well-documented risk of hemodynamic complications, and the higher cost of the device. PMID:1439032

  19. Epidemiology of clavicle fractures.

    PubMed

    Postacchini, Franco; Gumina, Stefano; De Santis, Pierfrancesco; Albo, Francesco

    2002-01-01

    An epidemiologic study of 535 isolated clavicle fractures treated in a hospital of a large metropolis during an 11-year period was performed. Data regarding patient's age and sex, side involved, mechanism of injury, and season in which the fracture occurred were obtained from the clinical records. Radiographic classification was performed with the Allman system. Clavicle fractures represented 2.6% of all fractures and 44% of those in the shoulder girdle. Most patients were men (68%), and the left side was involved in 61% of cases. Fractures of the middle third of the clavicle, which were the most common (81%), were displaced in 48% of cases and comminuted in 19%. Fractures of the medial third were the least common (2%). The prevalence of midclavicular fractures was found to decrease progressively with age, starting from the first decade of life when they represented 88.2% of all clavicle fractures and were undisplaced in 55.5% of cases. In adults, the incidence of displaced fractures, independent of location, was higher than that of undisplaced fractures. Traffic accidents were the most common cause of the injury. In the period under study, the incidence of fractures showed no significant change over time and no seasonal variation. PMID:12378163

  20. Capitellar and Trochlear Fractures.

    PubMed

    Carroll, Michael J; Athwal, George S; King, Graham J W; Faber, Kenneth J

    2015-11-01

    Fractures of the capitellum and trochlea account for a small proportion of elbow trauma. Clinicians need to be vigilant in their assessment as they are commonly associated with other injuries about the elbow. To optimize outcomes, the goals of management include a stable, anatomic reduction and early range of motion. Closed reduction of noncomminuted fractures may be successful but requires close follow-up. Open reduction and internal fixation is the preferred management of displaced capitellum-trochlear fractures. Elbow stiffness is the most commonly reported complication in operatively treated fractures. Arthroscopic-assisted reduction and internal fixation and arthroplasty are evolving management options. PMID:26498550

  1. A polyethylene liner scratch after revision hip arthroplasty performed to repair ceramic fracture.

    PubMed

    Hasegawa, Yukiharu; Sheng, Puyi; Kanoh, Toshiya; Seki, Taisuke; Matsuoka, Atsushi

    2012-05-01

    A 61-year-old man who had undergone revision total hip arthroplasty in 2000 was evaluated at our clinic in 2008, 1 day after feeling an abnormal clicking sensation in his left hip. Radiographs showed a fracture of the alumina ceramic liner of his acetabular component. A second revision total hip arthroplasty was performed with a 28-mm highly crosslinked polyethylene acetabular liner and an alumina femoral head. Sixteen months after the second revision, the patient experience sudden-onset hip pain. Radiographs revealed a fatigue fracture of the neck of a displaced stem. Analysis by scanning electron microscopy of the surface of the retrieved alumina ceramic femoral head revealed no scratches or wear, but analysis of the highly crosslinked polyethylene socket revealed third-body wear, scratches, irregularly shaped dips, and white ceramic particles. Elemental analysis of the white particles by an x-ray microanalyzer revealed the presence of aluminum and oxygen. PMID:21958938

  2. Pathological fractures in children

    PubMed Central

    De Mattos, C. B. R.; Binitie, O.; Dormans, J. P.

    2012-01-01

    Pathological fractures in children can occur as a result of a variety of conditions, ranging from metabolic diseases and infection to tumours. Fractures through benign and malignant bone tumours should be recognised and managed appropriately by the treating orthopaedic surgeon. The most common benign bone tumours that cause pathological fractures in children are unicameral bone cysts, aneurysmal bone cysts, non-ossifying fibromas and fibrous dysplasia. Although pathological fractures through a primary bone malignancy are rare, these should be recognised quickly in order to achieve better outcomes. A thorough history, physical examination and review of plain radiographs are crucial to determine the cause and guide treatment. In most benign cases the fracture will heal and the lesion can be addressed at the time of the fracture, or after the fracture is healed. A step-wise and multidisciplinary approach is necessary in caring for paediatric patients with malignancies. Pathological fractures do not have to be treated by amputation; these fractures can heal and limb salvage can be performed when indicated. PMID:23610658

  3. [Review of 19 cases of dislocation and fracture-dislocation of the cervical spine treated with anterior screw plates without intersomatic graft].

    PubMed

    Loembe, P M

    1993-01-01

    In comparison to posterior fixation by Roy-Camille plates which does not require bone grafting, 19 cases of anterior plate fixation, also without bone grafting, are presented (11 dislocations, 2 severe sprains, 4 fracture-dislocations and 2 "tear-drop" fractures of the lower cervical spine). A satisfactory osteoligamentary consolidation was obtained in every patient. The advantages of this technique are discussed. PMID:8484324

  4. Percutaneous screw placement in acetabular posterior column surgery: gender differences in implant positioning.

    PubMed

    Dienstknecht, Thomas; Müller, Michael; Sellei, Richard; Nerlich, Michael; Pfeifer, Christian; Krutsch, Werner; Fuechtmeier, Bernd; Berner, Arne

    2014-04-01

    Percutaneous reduction and periarticular screw implantation techniques have been successfully introduced in acetabular surgery. Image guided navigation techniques might be beneficial in increasing accuracy. However, a thorough understanding of standard values is needed to oversee pitfalls. This cadaver study was designed to identify reliable angulation values for screw implantation in the posterior acetabular column and to provide knowledge of the bony thickness for the periarticular corridor. Gender differences were specifically addressed. 27 embalmed cadaveric hemipelvic specimens (13 male, 14 female) were used. After soft-tissue removal posterior column acetabular screw placement was conducted by one experienced orthopaedic trauma surgeon under visibility. Radiographic verification of ideal screw placement was followed by radiographic assessment in three standard views and angulation values were assessed. Through bony dissection the maximal periarticular canal width was assessed. Various angulation values with regard to anatomical landmarks could be determined in the anteroposterior radiograph, as well as in the iliac oblique and the obturator oblique view. Gender differences were significant for all reference points with the pubic rami involved. The minimal canal width was 1.1cm in female and 1.6 cm in male specimen. The findings provide standard values for safe passages in percutaneous posterior column acetabular surgery. Gender differences have to be taken in consideration when planning the drill corridor. By adherence to standard values, screw placement can be performed safely. PMID:24182644

  5. Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements.

    PubMed

    Alshuhri, Abdullah A; Holsgrove, Timothy P; Miles, Anthony W; Cunningham, James L

    2015-08-01

    Current techniques for diagnosing early loosening of a total hip replacement (THR) are ineffective, especially for the acetabular component. Accordingly, new, accurate, and quantifiable methods are required. The aim of this study was to investigate the viability of vibrational analysis for accurately detecting acetabular component loosening. A simplified acetabular model was constructed using a Sawbones(®) foam block. By placing a thin silicone layer between the acetabular component and the Sawbones block, 2- and 4-mm soft tissue membranes were simulated representing different loosening scenarios. A constant amplitude sinusoidal excitation with a sweep range of 100-1500 Hz was used. Output vibration from the model was measured using an accelerometer and an ultrasound probe. Loosening was determined from output signal features such as the number and relative strength of observed harmonic frequencies. Both measurement methods were sufficient to measure the output vibration. Vibrational analysis reliably detected loosening corresponding to both 2 and 4 mm tissue membranes at driving frequencies between 100 and 1000 Hz (p < 0.01) using the accelerometer. In contrast, ultrasound detected 2-mm loosening at a frequency range of 850-1050 Hz (p < 0.01) and 4-mm loosening at 500-950 Hz (p < 0.01). PMID:26054805

  6. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... for use with bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the... metal (hemi-hip) acetabular metal cemented prosthesis shall have an approved PMA or a declared...

  7. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... for use with bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP is required to be filed with the... metal (hemi-hip) acetabular metal cemented prosthesis shall have an approved PMA or a declared...

  8. Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.

    PubMed

    Nieuwenhuis, Jeroen J; Malefijt, Jan de Waal; Hendriks, Jan C M; Gosens, Taco; Bonnet, Michel

    2005-06-01

    A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with different acetabular shell types were specifically analysed. Pelvic osteolysis first became manifest in the acetabular bone opposite to the holes in the metal shell. Osteolysis occurred predominantly adjacent to the central hole in the metal shell of threaded cups; widespread and larger defects were found in press fit cups with peripheral screw holes. Kaplan Meier survival analysis demonstrated a higher probability for retaining the threaded cup at 6 years (96%; 95%-confidence interval: 93-99%) compared to the survival of the press fit cup (66%; 95%-CI: 56-77%). The results suggest a negative relationship between backside wear, the larger number of holes in the cup, the extent of osteolysis and survival rate of the press fit cups. Based on these findings and supported by similar reports about osteolysis related to the same cup design, it was hypothesised that backside wear due to the insufficient locking mechanism of the Omnifit acetabular cup was the major cause of the unsatisfactory results in our patients. For this reason we discontinued using this type of uncemented socket. PMID:16035702

  9. Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty

    PubMed Central

    Manzano, Givenchy; Levin, Rayna A. C.; Mayor, Michael B.; Schwarzkopf, Ran

    2014-01-01

    Introduction: Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied extensively, however, only few reports have described its catastrophic wear. We report such a case of complete wear of the acetabular liner in a ceramic-on-polyethylene prosthesis in a 57-year adult male. Case Report: A 57-year adult male with a history of bilateral total hip arthroplasty presented to our institution with bilateral hip pain worst on the right. Range of motion was limited by pain on the right hip at the extremes of motion. Radiographs revealed severe osteolysis, heterotopic ossification, complete wear of the acetabular liner, bony impingement of the femoral greater trochanter on the acetabular rim and superior migration of the femoral head. All findings were confirmed intraoperatively. Revision of the acetabular components was performed, which successfully alleviated the patient’s symptoms. Conclusion: Failure of the ceramic-on-polyethylene liner in our patient is due to the use of a non-cross linked polyethylene liner, a highly active lifestyle, and poor follow up. Arthroplasty surgeons should be aware of this complication especially in highly active patients with a conventional polyethylene liner and chronic hip pain. PMID:27298960

  10. Assessment of bone healing on tibial fractures treated with wire osteosynthesis associated or not with infrared laser light and biphasic ceramic bone graft (HATCP) and guided bone regeneration (GBR): Raman spectroscopy study

    NASA Astrophysics Data System (ADS)

    Bastos de Carvalho, Fabíola; Aciole, Gilberth Tadeu S.; Aciole, Jouber Mateus S.; Silveira, Landulfo, Jr.; Nunes dos Santos, Jean; Pinheiro, Antônio L. B.

    2011-03-01

    The aim of this study was to evaluate, through Raman spectroscopy, the repair of complete tibial fracture in rabbits fixed with wire osteosynthesis - WO, treated or not with infrared laser light (λ 780nm, 50mW, CW) associated or not to the use of HATCP and GBR. Surgical fractures were created under general anesthesia (Ketamine 0.4ml/Kg IP and Xilazine 0.2ml/Kg IP), on the tibia of 15 rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with WO. Animals of groups III and V were grafted with hydroxyapatite + GBR technique. Animals of groups IV and V were irradiated at every other day during two weeks (16J/cm2, 4 x 4J/cm2). Observation time was that of 30 days. After animal death the specimens were kept in liquid nitrogen for further analysis by Raman spectroscopy. Raman spectroscopy showed significant differences between groups (p<0.001). It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of calcium hydroxyapatite.

  11. Thin-Walled Cross-Linked Acetabular Liners Need Not Exhibit Reduced Locking Strength.

    PubMed

    Murtha, Andrew S; Roy, Marcel E; Whiteside, Leo A; Tilden, David S; Schmitt, Krystal L

    2015-08-01

    Use of larger diameter femoral heads has emerged as a promising strategy to reduce the risk of dislocation after total hip arthroplasty, but thinning the walls of cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) acetabular liners to accommodate these larger heads may compromise the locking mechanism of the liner. The purpose of this study was to test the mechanical integrity of the locking mechanism in cross-linked and re-melted UHMWPE acetabular components with reduced wall thickness. The locking mechanism of cross-linked (100 kGy/re-melted) acetabular liners in sizes 50/28, 50/36, and 52/36 mm of 1 design was evaluated by lever-out tests and torsion tests. Torsion tests were performed at 2 angles to isolate the liner's locking tabs independent of the contribution of its central post. Lever-out testing demonstrated nominally reduced failure strength in 50/36-mm liners (13.3 N · m) compared with 50/28-mm liners (12.3 N · m; P=.0502), whereas the lever-out strength of 52/36-mm liners was 12.2±0.94 N · m. Failure torques were similar between 50/28- and 50/36-mm liners at 45° and 90°, but the failure torque of size 52/36-mm liners was significantly higher at each angle. The use of larger diameter femoral heads does not compromise the locking mechanism of thinned MicroSeal (Signal Medical Corp, Marysville, Michigan) acetabular liners. Use of a cross-linked UHMWPE acetabular liner, with a locking mechanism that is not compromised when the liner is thinned to a thickness of at least 2.86 mm, appears to be a biomechanically sound construct when articulated with large diameter femoral heads. PMID:26270761

  12. [Trochanteric femoral fractures].

    PubMed

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    At the present time proximal femoral fractures account for 30% of all fractures referred to hospitals for treatment. Our population is ageing, the proportion of patients with post-menopausal or senile osteoporosis is increasing and therefore the number of proximal femoral fractures requiring urgent treatment is growing too. In the age category of 50 years and older, the incidence of these fractures has increased exponentially. Our department serves as a trauma centre for half of Prague and part of the Central Bohemia Region with a population of 1 150 000. Prague in particular has a high number of elderly citizens. Our experience is based on extensive clinical data obtained from the Register of Proximal Femoral Fractures established in 1997. During 14 years, 4280 patients, 3112 women and 1168 men, were admitted to our department for treatment of proximal femoral fractures. All patients were followed up until healing or development of complications. In the group under study, 82% were patients older than 70 years; 72% of those requiring surgery were in their seventies and eighties. Men were significantly younger than women (p<0.001) and represented 30% of the group. The fractures were 2.3-times more frequent in women than in men. In the category under 60 years, men significantly outnumbered women (p<0.001). The patients with pertrochanteric fractures were, on the average, eight years older than the patients with intertrochanteric fractures, which is a significant difference (p<0.001). The mortality rate within a year of injury was about 30%. Trochanteric fractures accounted for 54.7% and femoral neck fractures for 45.3% of all fractures. The inter-annual increase was 5.9%, with more trochanteric than femoral neck fractures. There was a non-significant decrease in intertrochanteric (AO 31-A3) fractures. On the other hand, the number of pertrochanteric (AO 31-A1+2) fractures increased significantly (p<0.001). A total of 1 394 fractures were treated with a proximal

  13. Effects of recombinant human Bone Morphogenetic Protein-2 (rhBMP-2) in grade III open tibia fractures treated with unreamed nails-A clinical and health-economic analysis.

    PubMed

    Alt, Volker; Borgman, Benny; Eicher, Alexander; Heiss, Christian; Kanakaris, Nikolaos K; Giannoudis, Peter V; Song, Fujian

    2015-11-01

    Recombinant human Bone Morphogenetic Protein-2 (rhBMP-2) is licensed in Europe for open tibia fractures treated with unreamed nails. However, there is limited data available on the specific use of rhBMP-2 in combination with unreamed nails for open tibia fractures. The intention of the current study was to evaluate the medical and health-economic effects of rhBMP-2 in Gustilo-Anderson grade III open tibia fractures treated with unreamed nails based on individual patient data from two previously published studies. Linear regression analysis was performed on raw data of 90 patients that were either treated by standard of care with soft tissue management and unreamed nailing (SOC group) (n=50) or with rhBMP-2 in addition to soft tissue management and unreamed nailing (rhBMP-2 group) (n=40). For all types of revision, a significant lower percentage of patients (27.5%) of the rhBMP-2 group had to be revised compared to 48% of the patients of the SOC group (p=0.04). When only invasive secondary interventions such as bone grafting and nail exchange were considered, there was also a statistically significant reduction in the rhBMP-2 group with a revision rate of 10.0% (4 of 40 patients) compared to the SOC group with a revision rate of 28.0% (14 of 50 patients) (p=0.01). Mean fracture healing time of 228 days in the rhBMP-2 compared to 266 days in the SOC group was not statistically significant (p=0.24). Health-economic analysis based on a societal perspective with calculation of overall treatment costs after initial surgery and including productivity losses revealed savings of €6,239 per patient for Germany and €4,752 for the UK in favour of rhBMP-2 which was mainly driven by reduction of productivity losses. In conclusion, rhBMP-2 reduces secondary interventions in patients with grade III open tibia fractures treated with an unreamed nail and its use leads to financial savings for Germany and the UK from a societal perspective. PMID:26374949

  14. One Month Old Neglected Lisfrancs Fracture Dislocation Treated with Wagner’s External Fixator and Percutaneous Screw Fixation : A Case Report

    PubMed Central

    Kale, Dinesh R; Khadabadi, Nikhil A; Putti, Babu B; Jatti, Ravi S

    2014-01-01

    Introduction: Lisfrancs Fracture dislocation is not commonly seen and it often goes missed leading to numerous complications. We present a case of neglected Lisfrancs fracture dislocation who presented after 1 month and its management. Case Report: A 27-year-old man came with the complaints of pain and swelling of the right foot following a fall from a motorcycle 1 month back. On Radiographic evaluation it showed presence Lisfrancs fracture Dislocation with comminuted fracture of the proximal phalanx of the great toe and distal fibula fracture. Closed reduction was attempted initially which was unsuccessful and was followed by open reduction which also failed. Reduction was then achieved using Wagner’s external fixation distractor device and supplemented with percutaneously passed screws. The external fixator was continued for 3 weeks followed by below knee cast for 6 weeks. The patient regained normal gait and returned to work and his previous physical activity level without recurrent dislocation. Conclusion: This report highlights the necessity of prompt open reduction and the need of external fixation to achieve and maintain reduction in case of neglected cases. We advocate this approach to achieve reduction in neglected cases where open reduction is unsuccessful. PMID:27298958

  15. Comparison of Clinical Outcomes of Phalangeal Fracture Treated with Dorsolateral Approach or Post-middle Approach Using AO Mini Titanium Plate.

    PubMed

    Li, Guang; Liu, Shen; Chen, Guoting; Li, Zengchun; Liu, Yangzhou; Sun, Guixin; Lu, Qingyou; Li, Xia; Tan, Jun; Guan, Ming

    2015-12-01

    The aim of this study is to investigate the clinical outcomes of various fixation methods for proximal phalangeal fractures with Arbeitsgemeinschaft für Osteosynthesefragen (AO) mini titanium plate by dorsolateral approach or post-middle approach. Clinical results of 62 fingers of 53 patients with proximal phalangeal fracture were evaluated. For dorsolateral approach, the lateral bundle of the extensor tendon was drawn away to expose the fracture part of the bone. After reduction, the plate was located at the dorsolateral side of the bone. For post-middle approach, the extensor tendon was split to expose the fracture part of the bone. After reduction, the plate was fixed to the proximal phalangeal side of the bone, and the extensor tendon was repaired with 3-0 nonabsorbable silk sutures. We found low overall complication rates in both groups. The mean total active motion (TAM) for the dorsolateral group and post-middle group was 234.60° ± 22.63° and 221.08° ± 25.69°, respectively. There was a statistical significance between the two groups (P = 0.037 < 0.05), indicating that TAM was notably affected by various fixation methods. With AO mini titanium plate, movement in dorsolateral approach group was significantly higher than in post-middle approach group. Dorsolateral approach is an acceptable technique of incision for proximal phalangeal fractures. PMID:26730082

  16. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    PubMed

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. PMID:24559522

  17. A geometric morphometric analysis of acetabular shape of the primate hip joint in relation to locomotor behaviour.

    PubMed

    San Millán, Marta; Kaliontzopoulou, Antigoni; Rissech, Carme; Turbón, Daniel

    2015-06-01

    The description of acetabular shape variation among primates is essential for our understanding of the locomotor behaviour and ecology of both extant and fossil species. In this study, we use two-dimensional geometric morphometrics to examine variation in acetabular shape in human and non-human primates and to determine the degree to which it co-varies with locomotor behaviour, while taking both intra and inter-specific variation into account. To these ends, we examined the acetabulum of 303 left hip bones of 27 extant genera of primates (including humans) with different locomotor behaviours. After accounting for shape variation due to sex, size, and phylogeny, the results confirm that acetabular shape varies significantly across locomotor groups. The two most differentiated locomotor groups are leapers and slow-climbing quadrupeds, which exhibit a unique acetabular shape. Furthermore, the acetabulum of humans differed significantly from all other groups, while no significant differences existed between chimpanzees and gorillas. The most noticeable differences are detected in both cranial and dorsal areas and around the acetabular horns. This variation in acetabular morphology may have biomechanical implications at the level of the hip joint, potentially determining joint range motion and load distribution during locomotion. Given the increasing number of published studies on fossil pelves, our results are widely applicable to fossil analyses, with critical implications for paleoanthropological analyses about the complex locomotor behaviour of fossil specimens and their classification into locomotor groups, which may enhance our understanding of their ecological habits. PMID:25929707

  18. Fracture resistance exhibited by endodontically treated and retreated teeth shaped by ProTaper NEXT versus WaveOne: An in vitro study

    PubMed Central

    Khalap, Neha Deepak; Hegde, Vibha; Kokate, Sharad

    2015-01-01

    Aim: To compare the fracture resistance exhibited by teeth after primary endodontic treatment and retreatment. Materials and Methods: One hundred freshly extracted human teeth were selected. 20 samples served as control (untreated). Eighty experimental samples were divided into two groups (n = 40) for instrumentation using rotary Protaper NEXT (PTN) or reciprocating WaveOne (WO) files and obturated using warm lateral compaction. Half of the samples (n = 20) from each group were subjected to a load. The remaining half were subjected to retreatment using Protaper universal retreatment files (RFs) followed by a file larger than the master apical file used in groups 1 and 2 and reobturated. Group A: Control, Group B: PTN + obturation, Group C: WO + obturation, Group D: RF + PTN + obturation and Group E: RF + WO + obturation. The retreatment specimens were also subjected to load and the readings acquired were statistically analyzed. Result: When compared between the groups, control group exhibited the highest fracture resistance (P < 0.01). When multiple tests were performed, Group E exhibited significantly less fracture resistance (P < 0.01). Conclusion: Endodontic treatment and retreatment both results in lowering the fracture resistance of a tooth. PMID:26752838

  19. Arthroscopic assistance does not improve the functional or radiographic outcome of unstable intra-articular distal radial fractures treated with a volar locking plate: a randomised controlled trial.

    PubMed

    Yamazaki, H; Uchiyama, S; Komatsu, M; Hashimoto, S; Kobayashi, Y; Sakurai, T; Kato, H

    2015-07-01

    There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance. There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation (SD) 0.7) and 0.7 mm (SD 0.7) and 0.6 mm (SD 0.6) and 0.4 mm (SD 0.5), respectively; p = 0.18 and p = 0.35). Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate. PMID:26130352

  20. Distal third humeri fractures treated using the Synthes™ 3.5-mm extra-articular distal humeral locking compression plate: clinical, radiographic and patient outcome scores

    PubMed Central

    Lewis, James; Rao, Prasad; Parfitt, Dan; Mohanty, Khitish; Ghandour, Adel

    2014-01-01

    Background Conventional management protocols for distal humeral extra-articular fractures (e.g. conservative, double columnar plating) are often associated with complications. We aimed to describe our experience of using the Synthes™ 3.5-mm extra-articular distal humeral locking compression plate for treatment of extra-articular distal humeral fractures. Methods We prospectively studied 23 consecutive patients who underwent fixation, in a tertiary trauma centre, over 2 years. Data, including patient demographics, duration of follow-up, patient satisfaction, visual analogue score (VAS), Oxford Elbow Score, and final outcome on discharge, were collected and analyzed. Results Of the 23 patients (12 males, 11 females; mean age 47.5 years; range 18 years to 89 years), all fractures united radiologically and clinically after the index procedure, with a mean time to fracture union of 15.7 weeks (range 9 weeks to 34 weeks) and a mean time to discharge of 17.8 weeks (range 13 weeks to 34 weeks). Oxford Elbow Score was 36.5 (range 11 to 48) at 4.6 months postoperatively; at 20 months follow-up, it was 40 (range 14 to 48) and the VAS was 8.5 (range 5 to 10). One patient had radial nerve neuropraxia pre-operatively, and one postoperatively, and both recovered uneventfully 3 months postoperatively. Neither superficial, nor deep infections were observed in this cohort. Conclusions The present study reports satisfactory outcome with the usage of the Synthes plate for extra-articular fracture management. It has become the technique of choice in our centre because it provides excellent results.

  1. Early predictors of acetabular growth after closed reduction in late detected developmental dysplasia of the hip.

    PubMed

    Li, YiQiang; Xu, HongWen; Li, JingChun; Yu, LingJia; Liu, YuanZhong; Southern, Edward; Liu, HongSheng

    2015-01-01

    This study evaluates improvement of the acetabular index (AI) in patients with developmental dysplasia of the hip at 4 years after closed reduction, and determines the association between the final AI and a set of factors. Sixty-two patients (74 hips) treated with closed reduction were categorized into three groups according to age: group A (0-12 months, 18 hips), group B (13-18 months, 24 hips), and group C (>18 months, 32 hips). There was no difference in AI among the three groups before reduction (P=0.293). In groups A and C, the AI decreased significantly over time until 3 years after reduction and no differences were observed between the time points of 3 and 4 years. At 4 years after reduction, the AI of group C was significantly higher than that of groups A (P<0.001) and B (P=0.012). The overall AI improvement rate was 28.63%. The AI improvement rate of group A was significantly higher than that of group C (P=0.005). Pearson correlation analysis indicated no correlation between center-head distance discrepancy and the final AI (P=0.811). Linear regression suggested that age and initial AI correlated significantly with the final AI (R=0.617, F=15.031, P<0.001). Other factors, such as sex, center-edge angle of Wiberg, bilaterally involved, and avascular necrosis of the femoral head, showed no correlations with the final AI (P>0.05). According to the coefficients, initial AI (β1=0.432, P<0.001) had greater effect than age (β2=0.197, P=0.023) on the final AI. In conclusion, the AI decreases in all patients after reduction and stabilizes at 3 years after reduction. The AI improvement rate is correlated negatively with age. Age and initial AI are early predictors of the progress of AI after closed reduction in developmental dysplasia of the hip patients. PMID:25305044

  2. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density

    PubMed Central

    Finnilä, Sami; Moritz, Niko; SvedströM, Erkki; Alm, Jessica J; Aro, Hannu T

    2016-01-01

    Background and purpose Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. Patients and methods We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41–78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ −1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2–10) years. Results Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were “at risk” (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the10 cases were “at risk” in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3–48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. Interpretation Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually. PMID:26569616

  3. Evaluation of acetabular cup initial fixation by using resonance frequency principle.

    PubMed

    Henys, Petr; Capek, Lukas; Fencl, Jaroslav; Prochazka, Egon

    2015-01-01

    The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of dislocation failure is highest in the first year after arthroplasty implantation. The aim of the study was to quantitatively evaluate the implant-bone stability of a cementless acetabular cup prosthesis by using a device based on resonance frequency analysis. The evaluation of this device was done by finite element analysis and in vitro experiments. It was shown that not all the resonance frequencies can be measured by our device. The resonance frequencies vary within the range of 500-3000 Hz. The proposed power spectrum measurement gives the information about the absolute stiffness of the press-fit implant. PMID:25655952

  4. Uncemented acetabular components. Histologic analysis of retrieved hydroxyapatite-coated and porous implants.

    PubMed

    Bauer, T W; Stulberg, B N; Ming, J; Geesink, R G

    1993-04-01

    Histologic sections of five hydroxyapatite-coated acetabular components retrieved at autopsy (2 dual geometry and 3 threaded cup designs) were analyzed, and the extent and pattern of bone apposition were compared with that of an uncoated, porous (beaded) dual geometry acetabular cup that had been removed for repeated dislocations. The results show hydroxyapatite and bone apposition most prominent in areas of likely load transmission, primarily around the peripheral rim of the dual-geometry cups and at the peaks of the threads of the screw cups. Hydroxyapatite and bone may have been removed by remodeling from the grooves between the threads. Although no significant wear debris was identified, the screw holes were incompletely covered by bone. The dual-geometry designs generally showed somewhat more bone apposition than the threaded cups, but all implants demonstrated less bone than might have been predicted from radiographs. PMID:8386747

  5. Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability.

    PubMed

    Souffrant, R; Zietz, C; Fritsche, A; Kluess, D; Mittelmeier, W; Bader, R

    2012-01-01

    Primary stability of artificial acetabular cups, used for total hip arthroplasty, is required for the subsequent osteointegration and good long-term clinical results of the implant. Although closed-cell polymer foams represent an adequate bone substitute in experimental studies investigating primary stability, correct numerical modelling of this material depends on the parameter selection. Material parameters necessary for crushable foam plasticity behaviour were originated from numerical simulations matched with experimental tests of the polymethacrylimide raw material. Experimental primary stability tests of acetabular press-fit cups consisting of static shell assembly with consecutively pull-out and lever-out testing were subsequently simulated using finite element analysis. Identified and optimised parameters allowed the accurate numerical reproduction of the raw material tests. Correlation between experimental tests and the numerical simulation of primary implant stability depended on the value of interference fit. However, the validated material model provides the opportunity for subsequent parametric numerical studies. PMID:22817471

  6. The relationship between operative and radiographic acetabular component orientation: which factors influence resultant cup orientation?

    PubMed

    Grammatopoulos, G; Pandit, H G; da Assunção, R; McLardy-Smith, P; De Smet, K A; Gill, H S; Murray, D W

    2014-10-01

    There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph. PMID:25274911

  7. Lateral foot pain following open reduction and internal fixation of the fracture of the fifth metatarsal tubercle: treated by arthroscopic arthrolysis and endoscopic tenolysis

    PubMed Central

    Lui, Tun Hing

    2014-01-01

    We report a case of fracture of the tuberosity of the fifth metatarsal which was managed by tension band wiring and bone grafting. It was complicated by symptomatic fibrosis of the operated site involving the cubometatarsal joint, peroneus brevis tendon, peroneus tertius tendon and the long extensor tendon to the fifth toe. This was successfully managed by arthroscopic lysis of the involved joint and tendons. PMID:24744074

  8. The economic impact of surgically treated peri-prosthetic hip fractures on a university teaching hospital in Wales 7.5-year study.

    PubMed

    Jones, Andrew R; Williams, Tim; Paringe, Vishal; White, Simon P

    2016-02-01

    The number of total hip replacements taking place across the UK continues to grow. In an ageing population, with people placing greater demands on their prostheses, the number of peri-prosthetic fractures is increasing. We studied the economic impact this has on a large teaching hospital. All patients with peri-prosthetic femoral fracture in a 7.5 year period were identified. Radiographic and case note analysis was performed. Costings from the finance departments were obtained. 90 cases were identified, 58 female and 32 male, with a mean age of 76 (range: 38-91). 89 of the cases were managed surgically, 66% undergoing revision and 33% receiving open reduction and internal fixation. According to the Vancouver Classification, 3% were Type A, 79% Type B and 18% Type C. The mean length of stay was 43 days. The mean cost of management was £31,370 (range: £6885-£112,327). Patients with type C fractures had the highest mean length of stay at 53 days and mean cost of £33,417. Including rehabilitation costs, our study illustrated a mean cost of £31,370, roughly four times the current basic NHS tariff of £8552. Although implant costs are greater, treatment with revision where appropriate allows earlier weight bearing, reduced length of stay and lower overall cost. PMID:26689495

  9. An in vitro comparative evaluation of different intraorifice barriers on the fracture resistance of endodontically treated roots obturated with gutta-percha

    PubMed Central

    Gupta, Abhishek; Arora, Vipin; Jha, Padmanabh; Nikhil, Vineeta; Bansal, Parul

    2016-01-01

    Aim: To compare and evaluate the root reinforcement potential of four different intraorifice barriers: Mineral trioxide aggregate (MTA), resin-modified glass ionomer cement (RMGIC), fiber-reinforced composite (FRC), and nanohybrid composite (NC). Materials and Methods: Seventy-five mandibular premolars were decoronated to a standardized length, and prepared and obturated with gutta-percha and AH Plus sealer. Except for control specimens, the coronal 3-mm gutta-percha was removed and filled with different materials. The specimens (75) were divided into five groups (n = 15) on the basis of the intraorifice barrier material used. Group 1: MTA, Group 2: RMGIC, Group 3: FRC, Group 4: NC, Group 5: no barrier (control). Fracture resistance of the specimens was tested. Results: Fracture resistance of roots was significantly affected by the type of intraorifice barrier used and the following pattern was observed: RMGIC > FRC > NC > MTA. Conclusion: Intraorifice barriers can be regarded as a viable choice to reduce the occurrence of postendodontic root fractures. Among the four tested materials, RMGIC showed the maximum reinforcement. PMID:27099413

  10. Radiographic anatomy of the proximal femur: correlation with the occurrence of fractures

    PubMed Central

    Pires, Robinson Esteves Santos; Prata, Eric Fontes; Gibram, Athos Vilela; Santos, Leandro Emilio Nascimento; Lourenço, Paulo Roberto Barbosa de Toledo; Belloti, João Carlos

    2012-01-01

    Objective To evaluate the correlation between radiographic parameters of the proximal femur anatomy and fractures. Methods Three hundred and five digital x-rays of the pelvis were analyzed in the anteroposterior view. Of these x-rays, twenty-seven showed femoral neck or transtrochanteric fractures. The anatomical parameters analyzed were: femoral neck width (FNW), femoral neck length (FNL), femoral axis length (FAL), cervicodiaphyseal angle (CDA), acetabular tear-drop distance (ATD) and great trochanter-pubic symphysis distance (GTPSD). The analysis was performed by comparing the results of the x-rays with and without proximal femoral fracture, to establish a correlation between them. Results No differences were found between the anatomical parameters of the groups with and without proximal femoral fracture. Conclusion There was no association between anatomical changes in the proximal femur and greater susceptibility to fractures. Level of evidence IV, Cross-sectional Study. PMID:24453585

  11. Articular cartilage friction increases in hip joints after the removal of acetabular labrum.

    PubMed

    Song, Yongnam; Ito, Hiroshi; Kourtis, Lampros; Safran, Marc R; Carter, Dennis R; Giori, Nicholas J

    2012-02-01

    The acetabular labrum is believed to have a sealing function. However, a torn labrum may not effectively prevent joint fluid from escaping a compressed joint, resulting in impaired lubrication. We aimed to understand the role of the acetabular labrum in maintaining a low friction environment in the hip joint. We did this by measuring the resistance to rotation (RTR) of the hip, which reflects the friction of the articular cartilage surface, following focal and complete labrectomy. Five cadaveric hips without evidence of osteoarthritis and impingement were tested. We measured resistance to rotation of the hip joint during 0.5, 1, 2, and 3 times body weight (BW) cyclic loading in the intact hip, and after focal and complete labrectomy. Resistance to rotation, which reflects articular cartilage friction in an intact hip was significantly increased following focal labrectomy at 1-3 BW loading, and following complete labrectomy at all load levels. The acetabular labrum appears to maintain a low friction environment, possibly by sealing the joint from fluid exudation. Even focal labrectomy may result in increased joint friction, a condition that may be detrimental to articular cartilage and lead to osteoarthritis. PMID:22176711

  12. Postural correction reduces hip pain in adult with acetabular dysplasia: a case report

    PubMed Central

    Lewis, Cara L.; Khuu, Anne; Marinko, Lee

    2015-01-01

    Developmental dysplasia of the hip is often diagnosed in infancy, but less severe cases of acetabular dysplasia are being detected in young active adults. The purpose of this case report is to present a non-surgical intervention for a 31-year-old female with mild acetabular dysplasia and an anterior acetabular labral tear. The patient presented with right anterior hip and groin pain, and she stood with the trunk swayed posterior to the pelvis (swayback posture). The hip pain was reproduced with the anterior impingement test. During gait, the patient maintained the swayback posture and reported 6/10 hip pain. Following correction of the patient’s posture, the patient’s pain rating was reduced to a 2/10 while walking. The patient was instructed to maintain the improved posture. At the 1 year follow-up, she demonstrated significantly improved posture in standing and walking. She had returned to recreational running and was generally pain-free. The patient demonstrated improvement on self-reported questionnaires for pain, function and activity. These findings suggest that alteration of posture can have an immediate and lasting effect on hip pain in persons with structural abnormality and labral pathology. PMID:25731688

  13. Damage evolution in acetabular replacements under long-term physiological loading conditions.

    PubMed

    Wang, J-Y; Heaton-Adegbile, P; New, A; Hussell, J G; Tong, J

    2009-05-29

    Damage development in cemented acetabular replacements has been studied in bovine pelvic bones under long-term physiological loading conditions, including normal walking, stair climbing and a combined block loading with representative routine activities. The physiological loading conditions were achieved using a specially designed hip simulator for fixation endurance testing. Damage was detected and monitored using micro-CT scanning at regular intervals of the experiments, and verified by microscopic studies post testing. The results show that debonding at the bone-cement interface defined the failure of cement fixation in all cases, and debondings initiated near the dome of the acetabulum in the superior-posterior quadrant, consistent with the high-stress region identified from the finite element analysis of implanted acetabular models Zant, N.P., Heaton-Adegbile, P., Hussell, J.G., Tong, J., 2008b. In-vitro fatigue failure of cemented acetabular replacements-a hip simulator study. Journal of Biomechanical Engineering, Transactions of the ASME, 130, 021019-1-9]; [Tong, J., Zant, N.P., Wang, J-Y., Heaton-Adegbile, P., Hussell, J.G., 2008. Fatigue in cemented acetabulum. International Journal of Fatigue, 30(8), 1366-1375]. PMID:19345357

  14. The biological approach in acetabular revision surgery: impaction bone grafting and a cemented cup.

    PubMed

    Colo, Ena; Rijnen, Wim H C; Schreurs, Berend Willem

    2015-01-01

    Acetabular impaction bone grafting (IBG) in combination with a cemented cup in revision total hip arthroplasty (THA) is a proven and well-recognised technique which has been used in clinical practice for more than 35 years. Nowadays, with cemented prostheses tending to lose a larger part of the THA market every year in primary and revision cases, and many young surgeons being only trained in implanting uncemented prostheses, this technique is considered by many as technically demanding and time consuming, making its use less appealing. Despite this image and many new innovative techniques using uncemented implants in acetabular revisions over the last 25 years, IBG with a cemented cup is still one of the few techniques that really can reconstitute bone and respects human biology. In this era of many biologically-based breakthroughs in medicine, it is hard to explain that the solution of most orthopaedic surgeons for the extensive bone defects as frequently seen during acetabular revision surgery, consists of implanting bigger and larger metal implants. This review aims to put the IBG method into a historical perspective, to describe the surgical technique and present the clinical results. PMID:26044533

  15. The Morscher Press Fit acetabular component: a nine- to 13-year review.

    PubMed

    Gwynne-Jones, D P; Garneti, N; Wainwright, C; Matheson, J A; King, R

    2009-07-01

    We reviewed the results at nine to 13 years of 125 total hip replacements in 113 patients using the monoblock uncemented Morscher press-fit acetabular component. The mean age at the time of operation was 56.9 years (36 to 74). The mean clinical follow-up was 11 years (9.7 to 13.5) and the mean radiological follow-up was 9.4 years (7.7 to 13.1). Three hips were revised, one immediately for instability, one for excessive wear and one for deep infection. No revisions were required for aseptic loosening. A total of eight hips (7.0%) had osteolytic lesions greater than 1 cm, in four around the acetabular component (3.5%). One required bone grafting behind a well-fixed implant. The mean wear rate was 0.11 mm/year (0.06 to 0.78) and was significantly higher in components with a steeper abduction angle. Kaplan-Meier survival curves at 13 years showed survival of 96.8% (95% confidence interval 90.2 to 99.0) for revision for any cause and of 95.7% (95% confidence interval 88.6 to 98.4) for any acetabular re-operation. PMID:19567847

  16. Histology of damaged acetabular cartilage in symptomatic femoroacetabular impingement: an observational analysis.

    PubMed

    Kohl, Sandro; Hosalkar, Harish S; Mainil-Varlet, P; Krueger, Andreas; Buechler, Lorenz; Siebenrock, Klaus

    2011-01-01

    This prospective study on symptomatic adult patients with femoroacetabular impingement (FAI) who underwent open surgical intervention for management was designed to identify any obvious histological differences in the damaged acetabular cartilage within different subgroups of FAI. 20 patients underwent surgical intervention following safe surgical dislocation of the hip. There were 6 cases of cam impingement, 5 cases of pincer impingement and 9 of the mixed type. Pincer impingement cases demonstrated a characteristic focal, well-circumscribed and localized area of severe damage. On the other hand, cases with cam impingement showed a diffuse area of involvement affecting a larger surface of the acetabular cartilage, with degenerative changes, superficial erosions and some discontinuities. A small biopsy specimen of the acetabular rim including bone, cartilage and labrum from the affected zone was obtained in all cases. Histological evaluation was performed under normal and polarized light microscopy. Histological findings helped corroborate the pre-operative diagnosis and also define the unique nature of impingement and specific damage according to the type of impingement. PMID:21484743

  17. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    PubMed Central

    Ghanem, Mohamed; Glase, Almuth; Zajonz, Dirk; Roth, Andreas; Heyde, Christoph-E.; Josten, Christoph; von Salis-Soglio, Georg

    2016-01-01

    Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR) in multi-morbid patients. Patients and methods: During the period from January 1st 2007 to December 31st 2011 19 revision hip surgeries were performed in 19 patients, in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%). All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months). Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%. Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%). The most common complication encountered was the proximal migration of the bipolar head. The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%). Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as

  18. Osteopetrosis, femoral fracture, and chronic osteomyelitis caused by Staphylococcus aureus small colony variants (SCV) treated by girdlestone resection--6-year follow-up.

    PubMed

    Rolauffs, B; Bernhardt, T M; von Eiff, C; Hart, M L; Bettin, D

    2002-12-01

    Chronic osteomyelitis caused by Staphylococcus aureus small colony variants in combination with osteopetrosis is a unique combination of disorders that confronted us with major challenges. The therapeutic approach included four serial debridements and antimicrobial therapy. The aggressive treatment led to an instability of the brittle and hard osteopetrotic bone, and after 11 weeks, a fracture of the femoral neck occurred. A salvage procedure of the femur was performed, and the cultures obtained during this intervention remained negative. At a 6-year follow-up, the girdlestone situation still showed an acceptable functional outcome without any recurrence of osteomyelitis. PMID:12483342

  19. A Single Case of Rosai–Dorfman Disease Marked by Pathologic Fractures, Kidney Failure, and Liver Cirrhosis Treated with Single-Agent Cladribine

    PubMed Central

    Sasaki, Koji; Pemmaraju, Naveen; Westin, Jason R.; Wang, Wei-Lien; Khoury, Joseph D.; Podoloff, Donald A.; Moon, Bryan; Daver, Naval; Borthakur, Gautam

    2014-01-01

    Rosai–Dorfman disease (RDD) is a proliferative histiocytic disorder of unknown etiology, which is characterized by sinus histiocytosis with massive lymphadenopathy (1). In most cases, RDD has a benign course and treatment is not necessary. However, severe cases of RDD require treatment, and the treatment strategy is determined on the basis of the severity of the disease or the extranodal involvement of vital organs. We report a single case of RDD with atypical presentation of persistent constitutional symptoms, progressing pathologic fractures, and end-organ dysfunction, including acute kidney failure and liver cirrhosis with esophageal varices. PMID:25401088

  20. Elbow Fractures

    MedlinePlus

    ... and held together with pins and wires or plates and screws. Fractures of the distal humerus (see ... doctor. These fractures usually require surgical repair with plates and/or screw, unless they are stable. SIGNS ...

  1. Spontaneous fractures of the mandible concept & treatment strategy

    PubMed Central

    Marcussen, Mette

    2016-01-01

    Background Spontaneous fractures of the mandible dispose a surgical challenge in comparisons to fractures caused by trauma due to several complicating factors. Additionally: controversies exist concerning the terminology of the field. Material and Methods We conducted a retrospective study of all patients with mandibular fractures, with exclusion of fractures of the coronoid process and the alveolar process, treated at the Department of Oral and Maxillofacial Surgery, Aalborg University Hospital, Denmark between February 2003 and February 2013. Data collected from the medical records included sex, age, cause of fracture, site of fracture, and treatment. Results We identified 517 patients with 684 mandible fractures. Twenty-five of these were spontaneous fractures and 659 fractures were of traumatic origin. Condylar fractures rarely occur spontaneously, but constitute the majority of the traumatic fractures. Excluding these fractures from the analysis, we found a non-surgical approach in 14 of 24 (58%) of the spontaneous fractures and 110 of 376 (29%) of the traumatic fractures. This was statistically significant. Conclusions We found a statistical significant difference in favor of non-surgical approach in spontaneous fractures and we discussed the treatment challenges of these fractures. We addressed the terminological controversies regarding pathological fractures, and suggested the term spontaneous fractures denoting a fracture occurring during normal jaw function being either pathological or non-pathological. Key words:Mandibular fractures, spontaneous fractures, pathological fractures, traumatic fractures, treatment. PMID:26636905

  2. COMPARISON OF FRACTURED BEDROCK REMEDIATION

    EPA Science Inventory

    This report compares the technologies/approaches used at 7 Superfund sites to treat contaminated groundwater in fractured bedrock. The comparison shows how well each technology/approach met the stated goal, problems encountered, and lessons learned.

  3. Exposure of the superior gluteal neurovascular bundle for the safe application of acetabular reinforcement cages in complex revisions.

    PubMed

    Smitham, Peter J; Kosuge, Dennis; Howie, Donald W; Solomon, Lucian B

    2016-05-16

    The posterior approach to the hip is the most common extensile approach used, however exposure is limited superiorly by the superior gluteal neurovascular bundle (SGNB). The extra-pelvic course of the SGNB demonstrates variability between individuals, occasionally located only 1 cm from the acetabular rim. In complex acetabular reconstructions where the application of a reinforcement cage maybe required protecting the SGNB is challenging. The flanges of these cages are designed to sit on the ilium superior to the acetabular rim and to receive screws for fixation. The application of such cages may result in iatrogenic injury to the SGNB by way of forceful retraction or entrapment. We describe a technique that involves exposure and release of the SGNB such that the flanges of cage constructs may be safely applied. PMID:27079287

  4. Optimal acetabular component orientation estimated using edge-loading and impingement risk in patients with metal-on-metal hip resurfacing arthroplasty.

    PubMed

    Mellon, Stephen J; Grammatopoulos, George; Andersen, Michael S; Pandit, Hemant G; Gill, Harinderjit S; Murray, David W

    2015-01-21

    Edge-loading in patients with metal-on-metal resurfaced hips can cause high serum metal ion levels, the development of soft-tissue reactions local to the joint called pseudotumours and ultimately, failure of the implant. Primary edge-loading is where contact between the femoral and acetabular components occurs at the edge/rim of the acetabular component whereas impingement of the femoral neck on the acetabular component's edge causes secondary or contrecoup edge-loading. Although the relationship between the orientation of the acetabular component and primary edge-loading has been identified, the contribution of acetabular component orientation to impingement and secondary edge-loading is less clear. Our aim was to estimate the optimal acetabular component orientation for 16 metal-on-metal hip resurfacing arthroplasty (MoMHRA) subjects with known serum metal ion levels. Data from motion analysis, subject-specific musculoskeletal modelling and Computed Tomography (CT) measurements were used to calculate the dynamic contact patch to rim (CPR) distance and impingement risk for 3416 different acetabular component orientations during gait, sit-to-stand, stair descent and static standing. For each subject, safe zones free from impingement and edge-loading (CPR <10%) were defined and, consequently, an optimal acetabular component orientation was determined (mean inclination 39.7° (SD 6.6°) mean anteversion 14.9° (SD 9.0°)). The results of this study suggest that the optimal acetabular component orientation can be determined from a patient's motion and anatomy. However, 'safe' zones of acetabular component orientation associated with reduced risk of dislocation and pseudotumour are also associated with a reduced risk of edge-loading and impingement. PMID:25482661

  5. Pain Palliation by Percutaneous Acetabular Osteoplasty for Metastatic Hepatocellular Carcinoma

    SciTech Connect

    Hokotate, Hirofumi; Baba, Yasutaka; Churei, Hisahiko; Nakajo, Masayuki; Ohkubo, Kouichi; Hamada, Kenji

    2001-09-15

    A 68-year-old man with hepatocellular carcinoma and known skeletal metastasis developed right hip pain and gait disturbance due to an osteolytic metastasis in the right acetabulum. This was treated initially with chemoembolization and radiation therapy. When these procedures proved unsuccessful percutaneous injection of acrylic bone cement into the acetabulum was undertaken. Immediately after this procedure, he obtained sufficient pain relief and improved walking ability, which continued for 3 months until he died of hepatic insufficiency.

  6. Sports fractures.

    PubMed Central

    DeCoster, T. A.; Stevens, M. A.; Albright, J. P.

    1994-01-01

    Fractures occur in athletes and dramatically influence performance during competitive and recreational activities. Fractures occur in athletes as the result of repetitive stress, acute sports-related trauma and trauma outside of athletics. The literature provides general guidelines for treatment as well as a variety of statistics on the epidemiology of fractures by sport and level of participation. Athletes are healthy and motivated patients, and have high expectations regarding their level of function. These qualities make them good surgical candidates. Although closed treatment methods are appropriate for most sports fractures, an aggressive approach to more complicated fractures employing current techniques may optimize their subsequent performance. PMID:7719781

  7. Morphometric assessment of the canine hip joint using the dorsal acetabular rim view and the centre-edge angle.

    PubMed

    Meomartino, L; Fatone, G; Potena, A; Brunetti, A

    2002-01-01

    The dorsal acetabular rim (DAR) view of the hip joint can be used to assess the weightbearing portion of the acetabulum and the acetabular coverage, providing an adjunct to the conventional ventrodorsal (VD) view in the radiographic evaluation of hip dysplasia in the dog. A quantitative index of acetabular coverage in the DAR view, the acetabular slope (AS) angle, was originally proposed in 1990. The aim of the present study was to make a prospective, comparative assessment of a new parameter, the centre-edge (CE) angle, with the AS angle, for the evaluation of the acetabular coverage of the femoral head in the DAR view. The reliability and repeatability of the two parameters was assessed using the r(I) value of intraclass correlation coefficient (ICC) in a prospective study of 208 hip joints in large and giant breed dogs. An estimation of the added value of using the DAR view, compared with that of the VD standard view alone, was also assessed. The CE angle showed a higher r(I) value compared with the AS angle; in 26 per cent of hips of FCI classes A, B and C, the DAR view provided additional diagnostic information compared with the VD view, with respect to lateralisation and/or initial changes to the dorsal rim. It is concluded that the CE angle is more reliable than the AS angle in the evaluation of acetabular coverage, and that the DAR view provides valuable data compared with the VD view alone in the early stages of canine hip dysplasia. PMID:11833819

  8. Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population

    PubMed Central

    Xiao, Jian-Lin; Zuo, Jian-Lin; Liu, Peng; Qin, Yan-Guo; Li, Xue-Zhou; Liu, Tong; Gao, Zhong-Li

    2015-01-01

    Background: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. Methods: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. Results: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. Conclusions: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better. PMID:26063357

  9. [Vascular injuries complicating osteosynthesis in proximal femur fractures].

    PubMed

    Manner, M; Rösch, B; Roy, K

    1999-03-01

    While there are quite a number of reports on vascular injuries complicating hip arthropasty by acetabular component screw fixation, retractor tip pressure or extruding bone cement, the incidence of deep femoral vessel injuries in operative fixation of proximal femoral fractures is comparatively seldom described. We report on two patients with per- and subtrochanteric femoral fractures who sustained injuries of deep femoral artery branches during the implantation of a dynamic hip screw (DHS) and a dynamic condylar screw (DCS), which resulted in a massive thigh hematoma and a fist-size pseudoaneurysm respectively and necessitated surgical intervention in either case. We blame these vascular injuries on the pressure of Hohmann retractors exposing the femoral bone or on the drilling of boreholes for plate attachment. After discussing various operative procedures, we conclude that intramedullar implants are safer than plates with regard to potential vascular complications. PMID:10232039

  10. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    PubMed

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. PMID:25725589

  11. Current concept in dysplastic hip arthroplasty: Techniques for acetabular and femoral reconstruction

    PubMed Central

    Bicanic, Goran; Barbaric, Katarina; Bohacek, Ivan; Aljinovic, Ana; Delimar, Domagoj

    2014-01-01

    Adult patients with developmental dysplasia of the hip develop secondary osteoarthritis and eventually end up with total hip arthroplasty (THA) at younger age. Because of altered anatomy of dysplastic hips, THA in these patients represents technically demanding procedure. Distorted anatomy of the acetabulum and proximal femur together with conjoined leg length discrepancy present major challenges during performing THA in patients with developmental dysplasia of the hip. In addition, most patients are at younger age, therefore, soft tissue balance is of great importance (especially the need to preserve the continuity of abductors) to maximise postoperative functional result. In this paper we present a variety of surgical techniques available for THA in dysplastic hips, their advantages and disadvantages. For acetabular reconstruction following techniques are described: Standard metal augments (prefabricated), Custom made acetabular augments (3D printing), Roof reconstruction with vascularized fibula, Roof reconstruction with pedicled iliac graft, Roof reconstruction with autologous bone graft, Roof reconstruction with homologous bone graft, Roof reconstruction with auto/homologous spongious bone, Reinforcement ring with the hook in combination with autologous graft augmentation, Cranial positioning of the acetabulum, Medial protrusion technique (cotyloplasty) with chisel, Medial protrusion technique (cotyloplasty) with reaming, Cotyloplasty without spongioplasty. For femoral reconstruction following techniques were described: Distraction with external fixator, Femoral shortening through a modified lateral approach, Transtrochanteric osteotomies, Paavilainen osteotomy, Lesser trochanter osteotomy, Double-chevron osteotomy, Subtrochanteric osteotomies, Diaphyseal osteotomies, Distal femoral osteotomies. At the end we present author’s treatment method of choice: for acetabulum we perform cotyloplasty leaving only paper-thin medial wall, which we break during

  12. Current concept in dysplastic hip arthroplasty: Techniques for acetabular and femoral reconstruction.

    PubMed

    Bicanic, Goran; Barbaric, Katarina; Bohacek, Ivan; Aljinovic, Ana; Delimar, Domagoj

    2014-09-18

    Adult patients with developmental dysplasia of the hip develop secondary osteoarthritis and eventually end up with total hip arthroplasty (THA) at younger age. Because of altered anatomy of dysplastic hips, THA in these patients represents technically demanding procedure. Distorted anatomy of the acetabulum and proximal femur together with conjoined leg length discrepancy present major challenges during performing THA in patients with developmental dysplasia of the hip. In addition, most patients are at younger age, therefore, soft tissue balance is of great importance (especially the need to preserve the continuity of abductors) to maximise postoperative functional result. In this paper we present a variety of surgical techniques available for THA in dysplastic hips, their advantages and disadvantages. For acetabular reconstruction following techniques are described: Standard metal augments (prefabricated), Custom made acetabular augments (3D printing), Roof reconstruction with vascularized fibula, Roof reconstruction with pedicled iliac graft, Roof reconstruction with autologous bone graft, Roof reconstruction with homologous bone graft, Roof reconstruction with auto/homologous spongious bone, Reinforcement ring with the hook in combination with autologous graft augmentation, Cranial positioning of the acetabulum, Medial protrusion technique (cotyloplasty) with chisel, Medial protrusion technique (cotyloplasty) with reaming, Cotyloplasty without spongioplasty. For femoral reconstruction following techniques were described: Distraction with external fixator, Femoral shortening through a modified lateral approach, Transtrochanteric osteotomies, Paavilainen osteotomy, Lesser trochanter osteotomy, Double-chevron osteotomy, Subtrochanteric osteotomies, Diaphyseal osteotomies, Distal femoral osteotomies. At the end we present author's treatment method of choice: for acetabulum we perform cotyloplasty leaving only paper-thin medial wall, which we break during acetabular

  13. Analysis of spinal alignment and pelvic parameters on upright radiographs: implications for acetabular development

    PubMed Central

    Pytiak, Andrew; Bomar, James D.; Peterson, Jonathan B.; Schmitz, Matthew R.; Pennock, Andrew T.; Wenger, Dennis R.; Upasani, Vidyadhar V.

    2016-01-01

    The purpose of this study was to correlate measures of sagittal spinopelvic alignment [lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT) and pelvic incidence (PI)] and measures of acetabular coverage [lateral center edge angle (LCEA) and Tonnis angle] in asymptomatic adolescents on standing biplanar radiographs. We hypothesized that subjects with increased pelvic incidence and LL would have increased anterior PT and increased measures of acetabular coverage. Upright anteroposterior and lateral spinopelvic radiographs were obtained using EOS imaging technique. LCEA and Tonnis angle were calculated on the anteroposterior images and the lateral images were analyzed for LL, PI, PT and SS. LL was found to have a strong correlation with SS (rs = 0.786, P  <  0.001), moderate correlation with PI (rs  =  0.529, P  <  0.001), and a poor inverse correlation with PT (rs  = −0.167, P  =  0.018). However, LCEA was not found to be significantly correlated with PT (rs  =  0.084, P  =  0.238) and Tonnis angle was not found to be correlated with any of the sagittal spinopelvic measures. Healthy, asymptomatic adolescents with increased pelvic incidence and lumbar lordosis did not have increased anterior PT or increased measures of acetabular coverage. The correlations identified in previous cadaveric studies or clinical studies evaluating changes between supine and standing radiographs are not supported in this healthy adolescent population. Our findings may suggest that an individual’s acetabulum develops as a dynamic adaptation to one's particular sagittal spinopelvic alignment to optimize femoral head coverage. Level III. Diagnostic – Investigating a diagnostic test. PMID:27583160

  14. Periprosthetic Femur Fracture Occuring after Contralateral Neglected Femoral Neck Fracture

    PubMed Central

    Cankaya, Deniz; Toprak, Ali; IKilic, Enver; Bingol, Olgun; Tabak, Yalcin

    2016-01-01

    Introduction: Periprosthetic fractures of the femur are uncommon, but at times may lead to complications especially in elderly patients. As treatment of these fractures is difficult, prevention by identifying the risk factors is the best way to overcome these complex problems. Case Report: A periprosthetic right femur fracture associated with a neglected left femoral neck fracture in the contralateral femur in a 78-year-old elder woman patient is reported in the present article. We discuss the prevention of periprosthetic fractures after hip arthroplasty and address the risk factors associated with this complication. Conclusion: The present case emphasizes the importance of investigating and treating the cause of sudden onset of restriction on full weight-bearing in the contralateral limb, to prevent periprosthetic femoral fracture after hip arthroplasty in elderly patients. PMID:27299115

  15. Comparative Prospective Study of Load Distribution Projection Among Patients with Vertebral Fractures Treated with Percutaneous Vertebroplasty and a Control Group of Healthy Volunteers

    SciTech Connect

    Kelekis, Alexios Filippiadis, Dimitrios K. Vergadis, Chrysovalantis Tsitskari, Maria Nasis, Nikolaos Malagari, Aikaterini Kelekis, Nikolaos

    2013-04-12

    PurposeThrough a prospective comparison of patients with vertebral fractures and normal population, we illustrate effect of percutaneous vertebroplasty (PV) upon projection of load distribution changes.MethodsVertebroplasty group (36 symptomatic patients with osteoporotic vertebral fractures) was evaluated on an electronic baropodometer registering projection of weight bearing areas on feet. Load distribution between right and left foot (including rear-front of the same foot) during standing and walking was recorded and compared before (group V1) and the day after (group V2) PV. Control group (30 healthy asymptomatic volunteers-no surgery record) were evaluated on the same baropodometer.ResultsMean value of load distribution difference between rear-front of the same foot was 9.45 ± 6.79 % (54.72–45.28 %) upon standing and 14.76 ± 7.09 % (57.38–42.62 %) upon walking in the control group. Respective load distribution values before PV were 16.52 ± 11.23 and 30.91 ± 19.26 % and after PV were 10.08 ± 6.26 and 14.25 ± 7.68 % upon standing and walking respectively. Mean value of load distribution variation between the two feet was 6.36 and 14.6 % before and 4.62 and 10.4 % after PV upon standing and walking respectively. Comparison of load distribution variation (group V1–V2, group V1-control group) is statistically significant. Comparison of load distribution variation (group V2-control group) is not statistically significant. Comparison of load distribution variation among the two feet is statistically significant during walking but not statistically significant during standing.ConclusionsThere is a statistically significant difference when comparing load distribution variation prior vertebroplasty and that of normal population. After vertebroplasty, this difference normalizes in a statistically significant way. PV is efficient on equilibrium-load distribution improvement as well.

  16. Differences in Acetabular Rim Thickness in Patients with Unilateral Symptomatic Pincer-Type Femoroacetabular Impingement

    PubMed Central

    Weber, Alexander E.; Kuhns, Benjamin; Cvetanovich, Gregory; Inoue, Nozomu; Nho, Shane Jay

    2016-01-01

    Objectives: The objective of this study was to identify the location and magnitude of difference in acetabular rim morphology between the symptomatic and asymptomatic acetabula in a cohort of patients with symptomatic unilateral pincer-type FAI. Methods: After IRB approval, computed tomography (CT) scans of 43 patients (22 males, 21 females) diagnosed with unilateral pincer-type FAI were obtained. CT images of both hips were imported in DICOM format and segmented into 3-dimensional (3D) hemi-pelvises using 3D reconstruction software (Mimics, Materialise, Leuven, Belgium). The point-cloud data of the asymptomatic hemi-pelvis was mirrored onto the symptomatic side. Protrusion of the symptomatic side was recorded as a positive value and appeared as red on the color map (Figure 1). Data was collected in 3° intervals and analyzed by quadrant using the clock face method; reflecting the 12-3, 3-6, 6-9, and 9-12 o’clock positions. Results: The symptomatic acetabular rim was on average 0.39 ± 0.36 mm thicker than the corresponding location on the asymptomatic rim. When the acetabular clock face was broken up into quadrants, reflecting the 12-3, 3-6, 6-9, and 9-12 o’clock positions, the 12-3 o’clock position demonstrated the greatest difference between symptomatic and asymptomatic sides (Table 1). The 12-3 o’clock quadrant demonstrated significantly greater difference between symptomatic and asymptomatic sides (0.53±0.22 mm) as compared to the 3-6 o’clock position (0.39±0.27 mm; p=0.006), the 6-9 o’clock position (0.34±0.05 mm; p<0.001), and the 9-12 o’clock position (0.33±0.03; p<0.001). There was no correlation between gender and magnitude of difference at any location. Conclusion: Small changes in acetabular rim morphology, on the order of 0.5 mm or less can be the difference between symptomatic pincer-type FAI and the asymptomatic state. Knowledge of the healthy, unaffected side in unilateral FAI may provide a better template for rim recession rather

  17. All-Arthroscopic Reconstruction of the Acetabular Labrum by Capsular Augmentation

    PubMed Central

    Nwachukwu, Benedict U.; Alpaugh, Kyle; McCormick, Frank; Martin, Scott D.

    2015-01-01

    The acetabular labrum plays an important role in hip joint stability and articular cartilage maintenance. As such, reconstitution of the labral complex is ideal. In cases in which the labrum is too degenerative to allow adequate reconstruction with current repair techniques, a capsular augmentation is a novel technique that can be used to restore the labral structure. Use of capsular augmentation enables preservation of the donor-tissue blood supply with local tissue transfer, without adding significant complexity to the procedure or significant donor-site morbidity. PMID:26052488

  18. Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study.

    PubMed

    Ghosh, Rajesh

    2016-09-01

    The aim of the study is to determine failure of the cemented polyethylene acetabular component, which might occur due to excessive bone resorption, cement-bone interface debonding and fatigue failure of the cement mantle. Three-dimensional finite element models of intact and implanted pelvic bone were developed and bone remodeling algorithm was implemented for present analysis. Soderberg fatigue failure diagram was used for fatigue assessment of the cement mantle. Hoffman failure criterion was considered for prediction of cement-bone interface debonding. Results indicate fatigue failure of the cement mantle and implant-bone interface debonding might not occur due to bone remodeling. PMID:27408485

  19. Distal clavicle fractures in children☆

    PubMed Central

    Labronici, Pedro José; da Silva, Ricardo Rodrigues; Franco, Marcos Vinícius Viana; Labronici, Gustavo José; Pires, Robinson Esteves Santos; Franco, José Sergio

    2015-01-01

    Objective To analyze fractures of the distal clavicle region in pediatric patients. Methods Ten patients between the ages of five to eleven years (mean of 7.3 years) were observed. Nine patients were treated conservatively and one surgically. All the fractures were classified using the Nenopoulos classification system. Results All the fractures consolidated without complications. Conservative treatment was used for nine patients, of whom three were in group IIIB, three IIb, two IIa and one IV. The only patient who was treated surgically was a female patient of eleven years of age with a group IV fracture. Conclusion The treatment indication for distal fractures of the clavicle in children should be based on the patient's age and the displacement of the fragments. PMID:26962489

  20. [Treatment of hip fractures in elderly patients].

    PubMed

    Hack, Juliana; Bliemel, Christopher; Ruchholtz, Steffen; Bücking, Benjamin

    2015-04-01

    Hip fractures are among the most common fractures in elderly people. The annual number of femoral fractures is even expected to increase because of an aging society. Due to the high number of comorbidities, there are special challenges in treating geriatric hip fracture patients, which require a multidisciplinary management. This includes surgical treatment allowing full weight bearing in the immediate postoperative period, osteoporosis treatment and falls prevention as well as an early ortho-geriatric rehabilitation program. PMID:25919823

  1. Hip fracture - discharge

    MedlinePlus

    Inter-trochanteric fracture repair - discharge; Subtrochanteric fracture repair - discharge; Femoral neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge

  2. Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts

    PubMed Central

    Visconti, M A P G; Nascimento, H A; Dallemolle, R R; Ambrosano, G M; Freitas, D Q

    2015-01-01

    Objectives: To evaluate the influence of CBCT enhancement filters on the diagnosis of vertical root fractures (VRFs) in teeth with and without metal posts. Methods: The crowns of 40 uniradicular human teeth were removed and all roots were prepared. 20 teeth were randomly selected, and VRFs were induced using a universal testing machine. The i-CAT (Imaging Sciences International, Hatfield, PA) CBCT was used to scan teeth with and without intracanal metal posts using the following parameters: 0.2 voxel size, 8 × 8-cm scan size and acquisition time of 26.9 s. Images were evaluated by three observers with and without the use of the following filters: S9, smooth, smooth 3 × 3, sharpen, sharpen-mild and sharpen 3 × 3. Results: Intra- and interobserver agreement ranged from poor to moderate. Images with and without CBCT filters did not show significant differences regarding the area under the receiver operating characteristic curve, as well as sensitivity (p > 0.05). As for accuracy, the sharpen-mild filter was superior to the sharpen (p = 0.03), but these filters did not differ from all others. For specificity, S9, smooth and original images were superior to sharpen (p < 0.01). Results for teeth without posts differed from those for teeth with metal posts in all cases (p < 0.05). Conclusions: The use of enhancement filters in CBCT images has no influence on the diagnosis of VRFs in teeth with metal posts, and their use is not justified. PMID:25666446

  3. Comparing Single Versus Double Screw-Rod Anterior Instrumentation for Treating Thoracolumbar Burst Fractures with Incomplete Neurological Deficit: A Prospective, Randomized Controlled Trial.

    PubMed

    Yu, Yu; Wang, Juan; Shao, Gaohai; Wang, Qunbo; Li, Bo

    2016-01-01

    BACKGROUND Following a thoracolumbar burst fracture (TCBF), anterior screw-rods apply pressure upon the graft site. However, there is limited evidence comparing single screw-rod anterior instrumentation (SSRAI) to double screw-rod anterior instrumentation (DSRAI) for TCBFs. Our objective was to compare SSRAI versus DSRAI for TCBFs with incomplete neurological deficit. MATERIAL AND METHODS A total of 51 participants with T11-L2 TCBFs (AO classification: A3) were randomly assigned to receive SSRAI or DSRAI. Key preoperative, perioperative, and postoperative data were collected. Statistical analysis was conducted to determine the independent factors associated with inferior clinical outcomes, as well as the comparative efficacy of SSRAI and DSRAI. RESULTS There were no significant differences in the key demographic and clinical characteristics between the two groups (all p>0.05). Smoking status was significantly associated with inferior three-month and six-month Denis pain scores (Wald statistic=4.246, p=0.039). Both SSRAI and DSRAI were significantly effective in improving three-month and six-month postoperative degree of kyphosis, three-month and six-month postoperative ASIA impairment scale scores, three-month and six-month postoperative Denis pain score, and three-month and six-month postoperative Denis work score (all p<0.001). Although there were no significant differences between DSRAI and SSRAI with respect to all outcomes (all p>0.05), DSRAI displayed significantly longer operating times, as well as significantly larger operative blood losses (both p<0.001). CONCLUSIONS SSRAI may be preferable over DSRAI for TCBFs with incomplete neurological deficit due to its lower operating time and amount of operative blood loss. PMID:27197020

  4. Comparing Single Versus Double Screw-Rod Anterior Instrumentation for Treating Thoracolumbar Burst Fractures with Incomplete Neurological Deficit: A Prospective, Randomized Controlled Trial

    PubMed Central

    Yu, Yu; Wang, Juan; Shao, Gaohai; Wang, Qunbo; Li, Bo

    2016-01-01

    Background Following a thoracolumbar burst fracture (TCBF), anterior screw-rods apply pressure upon the graft site. However, there is limited evidence comparing single screw-rod anterior instrumentation (SSRAI) to double screw-rod anterior instrumentation (DSRAI) for TCBFs. Our objective was to compare SSRAI versus DSRAI for TCBFs with incomplete neurological deficit. Material/Methods A total of 51 participants with T11-L2 TCBFs (AO classification: A3) were randomly assigned to receive SSRAI or DSRAI. Key preoperative, perioperative, and postoperative data were collected. Statistical analysis was conducted to determine the independent factors associated with inferior clinical outcomes, as well as the comparative efficacy of SSRAI and DSRAI. Results There were no significant differences in the key demographic and clinical characteristics between the two groups (all p>0.05). Smoking status was significantly associated with inferior three-month and six-month Denis pain scores (Wald statistic=4.246, p=0.039). Both SSRAI and DSRAI were significantly effective in improving three-month and six-month postoperative degree of kyphosis, three-month and six-month postoperative ASIA impairment scale scores, three-month and six-month postoperative Denis pain score, and three-month and six-month postoperative Denis work score (all p<0.001). Although there were no significant differences between DSRAI and SSRAI with respect to all outcomes (all p>0.05), DSRAI displayed significantly longer operating times, as well as significantly larger operative blood losses (both p<0.001). Conclusions SSRAI may be preferable over DSRAI for TCBFs with incomplete neurological deficit due to its lower operating time and amount of operative blood loss. PMID:27197020

  5. Fracture pain-Traveling unknown pathways.

    PubMed

    Alves, Cecília J; Neto, Estrela; Sousa, Daniela M; Leitão, Luís; Vasconcelos, Daniel M; Ribeiro-Silva, Manuel; Alencastre, Inês S; Lamghari, Meriem

    2016-04-01

    An increase of fracture incidence is expected for the next decades, mostly due to the undeniable increase of osteoporotic fractures, associated with the rapid population ageing. The rise in sports-related fractures affecting the young and active population also contributes to this increased fracture incidence, and further amplifies the economical burden of fractures. Fracture often results in severe pain, which is a primary symptom to be treated, not only to guarantee individual's wellbeing, but also because an efficient management of fracture pain is mandatory to ensure proper bone healing. Here, we review the available data on bone innervation and its response to fracture, and discuss putative mechanisms of fracture pain signaling. In addition, the common therapeutic approaches to treat fracture pain are discussed. Although there is still much to learn, research in fracture pain has allowed an initial insight into the mechanisms involved. During the inflammatory response to fracture, several mediators are released and will putatively activate and sensitize primary sensory neurons, in parallel, intense nerve sprouting that occurs in the fracture callus area is also suggested to be involved in pain signaling. The establishment of hyperalgesia and allodynia after fracture indicates the development of peripheral and central sensitization, still, the underlying mechanisms are largely unknown. A major concern during the treatment of fracture pain needs to be the preservation of proper bone healing. However, the most common therapeutic agents, NSAIDS and opiates, can cause significant side effects that include fracture repair impairment. The understanding of the mechanisms of fracture pain signaling will allow the development of mechanisms-based therapies to effectively and safely manage fracture pain. PMID:26851411

  6. Tibial Tuberosity Avulsion Fracture and Open Proximal Tibial Fracture in an Adult

    PubMed Central

    Liu, Yu-Ping; Hao, Qing-Hai; Lin, Feng; Wang, Ming-Ming; Hao, Yue-Dong

    2015-01-01

    Abstract A displaced tibial tuberosity avulsion fracture associated with an open extra-articular proximal tibial diaphyseal fracture is an uncommon fracture pattern. This case report describes the successful management of such a fracture pattern in a 45-year old male using an open reduction and lag screw fixation of the tuberosity with a minimally invasive reduction and plate fixation of the proximal tibial diaphyseal fracture. A literature search was done to determine the expected clinical outcome of this fracture pattern. This is the first reported adult case of an avulsion fractures of the tibial tuberosity associated with an open proximal tibial diaphyseal fracture successfully treated by an anatomical reduction and fixation of the avulsion fracture of the tibial tuberosity combined with minimally invasive percutaneous plate osteosynthesis of the proximal tibial diaphyseal fractures. PMID:26426669

  7. Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up)

    PubMed Central

    Livesley, Peter

    2005-01-01

    We reviewed 81 consecutive ABG I primary total hip replacements implanted in 72 patients between January 1993 and December 1998. The mean follow-up was 8.2 (range 7–12) years. There was significant polyethylene wear and osteolysis associated with the acetabular cup .The cumulative survival of the cup with revision being the end point at 8.2 years was 95.1% (95% CI: 92–97.6%). However, the cumulative survival of the cup with revision and aseptic loosening together was 72% (95% CI: 61–78%) and survival of the acetabular liner for wear was 62% (95% CI: 48–74%). Stem survival with revision being the end point was 100%. In spite of significant radiological failures of the cups, most patients remained asymptomatic. Though results of the ABG stems in this series were good, we advocate a regular follow-up of all these hips in view of the poor outcome of the cups. PMID:16283307

  8. Multitechnique characterization of articular surfaces of retrieved ultrahigh molecular weight polyethylene acetabular sockets.

    PubMed

    Magnissalis, E A; Eliades, G; Eliades, T

    1999-01-01

    The articular surfaces of 10 retrieved ultrahigh molecular weight polyethylene acetabular sockets were studied by optical microscopy, X-ray fluorescence spectrometry, multiple internal reflectance FTIR spectroscopy, scanning electron microscopy, and wavelength dispersive X-ray microanalysis. The results revealed characteristic wear patterns including polishing, scratching, pitting, cratering, folding, shredding, burnishing, cracking, embedding of particles, and development of acquired biofilms with various degrees of mineralization. The biofilms formed were mainly of proteinaceous origin, and mineralized regions were composed of calcium phosphates with carbonate impurities. The crystallinity of the polyethylene at the articular surfaces was enhanced compared to the bulk, which was possibly due to the cold work produced in vivo. The mineralized regions were classified into two groups based on the grey levels of the backscattered images obtained. The high-contrast regions that were mainly composed of Ca and P with traces of Al and Si were associated with bone fragments; the low-contrast regions composed of K, Na, Ca, Mg, Si, Al, Fe, Cl, and P were associated with acquired biofilm calcification, which implies the active engagement of biofilms in the long term performance of acetabular sockets in vivo. PMID:10398042

  9. Towards the optimal design of an uncemented acetabular component using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Ghosh, Rajesh; Pratihar, Dilip Kumar; Gupta, Sanjay

    2015-12-01

    Aseptic loosening of the acetabular component (hemispherical socket of the pelvic bone) has been mainly attributed to bone resorption and excessive generation of wear particle debris. The aim of this study was to determine optimal design parameters for the acetabular component that would minimize bone resorption and volumetric wear. Three-dimensional finite element models of intact and implanted pelvises were developed using data from computed tomography scans. A multi-objective optimization problem was formulated and solved using a genetic algorithm. A combination of suitable implant material and corresponding set of optimal thicknesses of the component was obtained from the Pareto-optimal front of solutions. The ultra-high-molecular-weight polyethylene (UHMWPE) component generated considerably greater volumetric wear but lower bone density loss compared to carbon-fibre reinforced polyetheretherketone (CFR-PEEK) and ceramic. CFR-PEEK was located in the range between ceramic and UHMWPE. Although ceramic appeared to be a viable alternative to cobalt-chromium-molybdenum alloy, CFR-PEEK seems to be the most promising alternative material.

  10. New method for determining in vitro structure stiffness of ceramic acetabular liners under different impact conditions.

    PubMed

    Eichhorn, Stefan; Steinhauser, Erwin; Gradinger, Reiner; Burgkart, Rainer

    2012-05-01

    Increasing both patient mobility and prosthesis life span requires improvements in the range of motion and wear behavior of the liner. With the use of new composite alumina-zirconia ceramic materials, the same stability of the liner can be achieved at lower wall thickness than it is possible with alumina-only materials. The aim of this study was developing a method for determining the in vitro structure stiffness of ceramic acetabular liners against impact stresses. The first trials were performed with a common alumina acetabular liner type (Ceramtec; Biolox forte; diameter 28 mm; thickness 7 mm) and a new type of alumina-zirconia (Ceramtec Biolox delta; same dimensions) liner. The clinically established alumina liner was reproducibly damaged using worst case Separation/subluxation equivalent to one-fourth or half of the head diameter, and an impact load of 15 J. The liners containing the new alumina-zirconia material were not damaged in any of the trials up to an impact load of 20 J and half head diameter offset. PMID:22197061

  11. Vibrational spectroscopy study of the oxidation of Hylamer UHMWPE explanted acetabular cups sterilized differently

    NASA Astrophysics Data System (ADS)

    Reggiani, Matteo; Tinti, Anna; Visentin, Manuela; Stea, Susanna; Erani, Paolo; Fagnano, Concezio

    2007-05-01

    Ultra-high-molecular-weight polyethylene (UHMWPE) has been used for over 40 years for acetabular cups in total hip joint prosthesis. Hylamer is a hot isostatically pressed material with high crystallinity. Early loosening due to extensive oxidation and phase transformation has been observed for this material. To analyze the reasons for its high tendency to oxidize, we have examined by FT-IR spectroscopy explanted acetabular cups γ-sterilized in different ways. The oxidation and wear rate observed were: Hylamer cups γ-sterilized in air with a long shelf life > Hylamer cups γ-sterilized in air with short shelf life ⩾ Hylamer cups γ-sterilized in nitrogen. Our data indicate the important role of the shelf life on the oxidation of the cups: the samples γ-sterilized in air characterized by a shelf life greater than 3 years showed severe oxidation, a high wear rate, and marked debris production with delamination and the formation of a brittle zone in the more oxidated regions. In these regions we observed an increase in crystallinity, which was probably due to the decrease in the molecular weight of PE. The high oxidation was probably due to the modifications induced by the material treatment.

  12. Preliminary analysis on the MD-4® plasma-sprayed titanium acetabular component☆

    PubMed Central

    de Araújo Loures, Elmano; Simoni, Leandro Furtado; Leite, Isabel Cristina Gonçalves; Loures, Daniel Naya; Loures, Clarice Naya

    2015-01-01

    Objectives To evaluate the short-term performance of a type of implant manufactured in Brazil. Methods This study analyzed a cohort of 60 patients who underwent implantation of MD-4® acetabular components during primary hip arthroplasty procedures performed between January 1, 2010, and August 1, 2012. The patients were studied retrospectively with regard to clinical behavior, stability and radiological osseointegration. The patients were followed up for a minimum of 12 months and a maximum of 42 months (mean: 27) and were evaluated by means of the Harris Hip Score, SF-36 questionnaire and serial conventional radiographs. Results All the components were radiologically stable, without evidence of migration or progressive radiolucency lines. On average, the Harris Hip Score evolved from 36.1 to 92.1 (p < 0.001) and the SF-36 showed significant increases in all its domains (p < 0.001). No differences were observed among patients with osteoarthrosis, osteonecrosis, hip dysplasia or other conditions. Conclusions The short-term results showed clinical and radiological signs of stability and osseointegration of the implants, which may represent a predictive factor regarding medium-term survival of this acetabular component. PMID:26229918

  13. Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

    PubMed Central

    Shen, Fu-Wen; Lu, Zhen

    2010-01-01

    Background The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. Questions/purposes We asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in the liner affected by thickness? Methods Wear rates were measured in a hip simulator and stresses were calculated using finite element modeling. Results Without crosslinking, the wear rate was 4% to 10% greater with a 36-mm diameter than a 28-mm diameter. With crosslinking, wear was 9% lower with a 36-mm diameter without metal backing and 4% greater with metal backing. Reducing the thickness from 6 mm to 3 mm increased the contact stress by 46%, but the wear rate decreased by 19%. Conclusions The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm. Clinical Relevance The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated, neither wear nor stresses in the polyethylene are limiting factors in the use of larger-diameter, thinner cups to resist dislocation. PMID:20848244

  14. The use of fibre-based demineralised bone matrix in major acetabular reconstruction: surgical technique and preliminary results

    PubMed Central

    Karoubi, Mathieu; Dumaine, Valérie; Courpied, Jean Pierre

    2010-01-01

    Acetabular osteolysis associated with socket loosening is one of the main long-term complications of total hip arthroplasty. In case of major bone loss, where <50% host bone coverage can be obtained with a porous-coated cementless cup, it is generally agreed that a metal ring or cage in association with a cemented component and allograft bone should be used. In order to promote allograft bone consolidation and incorporation, we have associated demineralised bone matrix (DBM, Grafton® A Flex) to the construct ion. Here we describe the technical details of major acetabular reconstruction using the Kerboull acetabular reinforcement device with allograft bone and DBM. This device has a hook that must be placed under the teardrop of the acetabulum and a plate for iliac fixation. The main advantages of this device are help in restoring the normal centre of hip rotation, guiding the reconstruction and partially unloading the graft. The Kerboull acetabular reinforcement device has provided a 92% survival rate free of loosening at 13-year follow-up in a consecutive series of 60 type III and IV deficiencies. Our preliminary results using DBM indicate faster allograft consolidation and remodelling. PMID:21057788

  15. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  16. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  17. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  18. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  19. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  20. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  1. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  2. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  3. Fractures of the cervical spine

    PubMed Central

    Marcon, Raphael Martus; Cristante, Alexandre Fogaça; Teixeira, William Jacobsen; Narasaki, Douglas Kenji; Oliveira, Reginaldo Perilo; de Barros Filho, Tarcísio Eloy Pessoa

    2013-01-01

    OBJECTIVES: The aim of this study was to review the literature on cervical spine fractures. METHODS: The literature on the diagnosis, classification, and treatment of lower and upper cervical fractures and dislocations was reviewed. RESULTS: Fractures of the cervical spine may be present in polytraumatized patients and should be suspected in patients complaining of neck pain. These fractures are more common in men approximately 30 years of age and are most often caused by automobile accidents. The cervical spine is divided into the upper cervical spine (occiput-C2) and the lower cervical spine (C3-C7), according to anatomical differences. Fractures in the upper cervical spine include fractures of the occipital condyle and the atlas, atlanto-axial dislocations, fractures of the odontoid process, and hangman's fractures in the C2 segment. These fractures are characterized based on specific classifications. In the lower cervical spine, fractures follow the same pattern as in other segments of the spine; currently, the most widely used classification is the SLIC (Subaxial Injury Classification), which predicts the prognosis of an injury based on morphology, the integrity of the disc-ligamentous complex, and the patient's neurological status. It is important to correctly classify the fracture to ensure appropriate treatment. Nerve or spinal cord injuries, pseudarthrosis or malunion, and postoperative infection are the main complications of cervical spine fractures. CONCLUSIONS: Fractures of the cervical spine are potentially serious and devastating if not properly treated. Achieving the correct diagnosis and classification of a lesion is the first step toward identifying the most appropriate treatment, which can be either surgical or conservative. PMID:24270959

  4. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter

    PubMed Central

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Back, In Hwa; Eom, Kyeong Soo

    2016-01-01

    Purpose Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. Materials and Methods This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Results Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Conclusion Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment.

  5. Percutaneous Vertebroplasty for Osteoporotic Compression Fracture: Multivariate Study of Predictors of New Vertebral Body Fracture

    SciTech Connect

    Komemushi, Atsushi Tanigawa, Noboru; Kariya, Shuji; Kojima, Hiroyuki; Shomura, Yuzo; Komemushi, Sadao; Sawada, Satoshi

    2006-08-15

    Purpose. To investigate the risk factors and relative risk of new compression fractures following vertebroplasty. Methods. Initially, we enrolled 104 consecutive patients with vertebral compression fractures caused by osteoporosis. A total of 83 of the 104 patients visited our hospital for follow-up examinations for more than 4 weeks after vertebroplasty. Logistic regression analysis of the data obtained from these 83 patients was used to determine relative risks of recurrent compression fractures, using 13 different factors. Results. We identified 59 new fractures in 30 of the 83 patients: 41 new fractures in vertebrae adjacent to treated vertebrae; and 18 new fractures in vertebrae not adjacent to treated vertebrae. New fractures occurred in vertebrae adjacent to treated vertebrae significantly more frequently than in vertebrae not adjacent to treated vertebrae. Only cement leakage into the disk was a significant predictor of new vertebral body fracture after vertebroplasty (odds ratio = 4.633). None of the following covariates were associated with increased risk of new fracture: age, gender, bone mineral density, the number of vertebroplasty procedures, the number of vertebrae treated per procedure, the cumulative number of vertebrae treated, the presence of a single untreated vertebra between treated vertebrae, the presence of multiple untreated vertebrae between treated vertebrae, the amount of bone cement injected per procedure, the cumulative amount of bone cement injected, cement leakage into the soft tissue around the vertebra, and cement leakage into the vein.

  6. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.

    PubMed

    Bellini, Chiara Maria; Galbusera, Fabio; Ceroni, Roberto Giacometti; Raimondi, Manuela Teresa

    2007-03-01

    The primary stability of cementless acetabular components is a prerequisite for their clinical success. The target of the present study was to analyse possible effects of post-operative joint loading on the initial mechanical stability of a press-fitted acetabular prosthesis. For this purpose, a three-dimensional finite element model of the pelvic bone with acetabular reconstruction was set-up. The analysis included two steps: (1) simulation of the prosthesis press-fit implantation and (2) simulation of the instant of peak resultant hip loading during the one-legged stance. The difference between the contact pressures at the bone/implant interface, at the end of the second step and those at the end of the first step was calculated and assumed as an index of variation in mechanical contact due to post-operative weight bearing. The results show that, due to hip loading, contact pressures given by press-fit increase in the postero-superior acetabular region but decrease in the antero-inferior acetabular region. The calculated area in which the contact pressures decrease extend to about 30% of the total contact surface. These results imply that post-operative joint loading significantly reduces the mechanical stability given by press-fit. The decrease in contact pressures at the bone/implant interface may result in a lack of osteointegration, possibly hindering the implant secondary stability. It may also create a route for wear debris, possibly favouring periprosthetic osteolysis, which may lead to further loss in contact and clinical failure of the implant due to loosening. PMID:16569508

  7. Monitoring the press-fit insertion of an acetabular cup by impact measurements: influence of bone abrasion.

    PubMed

    Michel, Adrien; Bosc, Romain; Mathieu, Vincent; Hernigou, Philippe; Haiat, Guillaume

    2014-10-01

    Press-fit procedures used for the insertion of cementless hip prostheses aim at obtaining optimal implant primary stability. We have previously used the measurement of impact duration to follow the insertion of the acetabular cup implant within bone tissue. The aim of this study was to investigate the variation of the value of the impact momentum due to successive insertions of the acetabular cup into bone tissue. The results obtained with impact momentum and contact duration measurements were compared. A total of 10 bovine bone samples were subjected to three successive procedures consisting of 10 reproducible impacts (3.5 kg falling 40 mm). Each procedure aimed at inserting the acetabular cup implant into the same bone cavity. The time variation of force during each impact was recorded by a force sensor, allowing the measurement of the impact duration (I 1) and momentum (I 2). The value of I 2 increased as a function of the impact number and reached a constant value after N 2 = 5.07 ± 1.31 impacts. Moreover, statistical analyses show that N 2 decreased significantly as a function of the number of experiments, which may be due to abrasion phenomena at the bone-implant interface. Abrasion phenomena led to a faster insertion of the acetabular cup when the implant had been previously inserted into the same bone cavity. An empirical analytical model considering a flat punch configuration to model the bone-implant contact conditions was used to understand the trend of the variation of I 2 during the insertion of the acetabular cup. The measurement of the force during impacts is useful to assess the bone-implant interface properties, but needs to be validated in the clinic to be useful for orthopaedic surgeons intra-operatively. PMID:25258009

  8. Stress fractures of the olecranon in javelin throwers.

    PubMed

    Hulkko, A; Orava, S; Nikula, P

    1986-08-01

    Between the years 1977 and 1984, four javelin throwers with a stress fracture of the olecranon were seen and treated. In one patient, acute painful dislocation of the fracture occurred during a competitive throw. Two patients had stress fracture of the tip. The fracture treated conservatively healed in 18 months. The patient treated by excision of the tip was able to throw after 2 months. Two patients had slightly oblique, more distally located stress fractures, which were treated with a tension band and 2 Kirschner wires. The fractures healed in 4 months. One of the patients had a refracture 11 months after the primary operation. It was successfully treated with a compression screw and two bone pegs. Because of the high risk of delayed union and nonunion, stress fractures of the olecranon should be treated operatively in javelin throwers. PMID:3759300

  9. Fracturing rigid materials.

    PubMed

    Bao, Zhaosheng; Hong, Jeong-Mo; Teran, Joseph; Fedkiw, Ronald

    2007-01-01

    We propose a novel approach to fracturing (and denting) brittle materials. To avoid the computational burden imposed by the stringent time step restrictions of explicit methods or with solving nonlinear systems of equations for implicit methods, we treat the material as a fully rigid body in the limit of infinite stiffness. In addition to a triangulated surface mesh and level set volume for collisions, each rigid body is outfitted with a tetrahedral mesh upon which finite element analysis can be carried out to provide a stress map for fracture criteria. We demonstrate that the commonly used stress criteria can lead to arbitrary fracture (especially for stiff materials) and instead propose the notion of a time averaged stress directly into the FEM analysis. When objects fracture, the virtual node algorithm provides new triangle and tetrahedral meshes in a straightforward and robust fashion. Although each new rigid body can be rasterized to obtain a new level set, small shards can be difficult to accurately resolve. Therefore, we propose a novel collision handling technique for treating both rigid bodies and rigid body thin shells represented by only a triangle mesh. PMID:17218752

  10. Management of atrophic mandible fractures.

    PubMed

    Madsen, Matthew J; Haug, Richard H; Christensen, Bryan S; Aldridge, Eron

    2009-05-01

    Traumatic facial fractures that were once rarely encountered now present with increasing frequency in the elderly population. Included in this group of fractures are those of the atrophic edentulous mandible. As patients age and become edentulous, atrophy of the mandibular alveolar ridges and adjacent basal bone reduces bony surface area, bone density, and blood supply, making the mandible more brittle and increasing the likelihood of mandibular fracture during a traumatic event. Surgical treatment of these fractures has become more predictable and less morbid. However, because these fractures present so infrequently, many surgeons lack the relevant experience in handling them, and thus find the reduction and fixation of such injuries difficult. A number of techniques have been employed to treat this injury. This article reviews the more common modalities and presents updates on accepted surgical treatments. PMID:19348982

  11. [Recent progress in orthopaedic managements of osteoporosis-related fractures].

    PubMed

    Yamamoto, Seizo

    2011-07-01

    Recent progress in orthopaedic treatment of osteoporosis-related fractures was reviewed. In the treatment of femoral neck fractures, impacted or nondisplaced type is treated by three cannulated cancellous pins. Displaced type of femoral neck fracture is treated by bipolar prosthesis. Results of femoral neck fractures are influenced by the complications of each patients. Osteoporotic spine fractures are commonly healed within 2 or 3 months. Spinal compression with paraparesis or paraplegia is unusual complication in burst type of spine fractures. Surgical decompression, bone grafting and stabilization with instrumentation can result in some correction of deformity and neurogenic recovery. Distal radius fractures are common fractures in the eldery. Recently advances includes external fixation and plate fixation for the comminuted fractures in the distal radius. Treatments of osteoporosis-related fractures are still difficult problems to be resolved. PMID:21774371

  12. Rehabilitation in extremity fractures.

    PubMed

    Moskowitz, E

    1975-03-01

    General principles in the rehabilitation of a patient with an extremity fracture include: treat the patient, not the x-ray; move all joints not immobilized; prevent disuse atrophy; use gravity to assist in mobilizing a joint; stabilize proximal joints to avoid reverse action of biarticular muscles; permit early protected weight bearing until adequate joint mobility is achieved; appropriately instruct the patient in a home program, and avoid all stretching. PMID:1114932

  13. Displacement and Stress Analysis around the Artificial Acetabular Cup in a Total Hip Replacement

    NASA Astrophysics Data System (ADS)

    Kakunai, Satoshi; Tachibana, Hiroyuki; Sakamoto, Tohru; Abo, Masayoshi; Ikeda, Daisaku; Fujiwara, Hiroo

    In order to improve the service life of the artificial acetabular cup in a total hip replacement, it is important to determine the best material and design, and to assess the mechanical behavior around the cup. In this study, electronic speckle interferometry (ESPI) and the two-dimensional finite element method (FEM) are employed to investigate the mechanical behavior. The influence of the cancellous bone and cup thickness on mechanical behavior around the cup was investigated. Good agreement of the cup model was found between the ESPI measurements and FEM predictions. The following results were obtained. (1) Cancellous bone with a porous structure can be measured by the ESPI method. (2) There are discontinuities of the displacement distribution in the transverse direction in each boundary region of the cup, bone cement and cancellous bone. (3) The maximum shear stress exists in the boundary region of the cup and bone cement.

  14. Precooling an acetabular liner makes its insertion into a metal shell easier.

    PubMed

    Kyle, Richard F; Bourgeault, Craig A; Lew, William D; Bechtold, Joan E

    2006-02-01

    Temporary shrinkage of an acetabular polyethylene liner due to precooling could reduce the force required to snap the liner into its metal shell. This study documented cooling and heating rates of liners with a particular locking mechanism design, determined forces required to seat liners in their shells as a function of temperature, and quantified the force surgeons can exert with their thumbs when seating a liner. It took up to 8 minutes to cool 58- and 70-mm liners in an ice-water bath from room temperature to near 0 degrees C, and up to 24 minutes to subsequently warm these liners to near body temperature. Forces required to seat liners were greater at room and body temperatures than at 0 degrees C. Liners precooled to 0 degrees C required insertion forces that could be generated manually by surgeons. PMID:16520215

  15. Ten-year results of a press-fit, porous-coated acetabular component.

    PubMed

    Grobler, G P; Learmonth, I D; Bernstein, B P; Dower, B J

    2005-06-01

    We retrospectively reviewed, ten years after surgery, 100 consecutive total hip replacements in which the Duraloc 300 cup had been used. Post-operative radiographs were analysed for placement of the cup and interface gaps and follow-up radiographs for lucent lines, osteolysis, wear and migration. All the components were found to be stable with no evidence of loosening. The mean rate of wear was 0.12 mm/year. Three hips developed acetabular osteolysis at the level of the apex hole. Two have successfully undergone bone grafting without removal of the implants and one patient is awaiting surgery. The Duraloc 300 cup has a survival of 100% at ten years with no aseptic loosening and a low incidence of pelvic osteolysis. PMID:15911659

  16. Does the ingrowth surface make a difference? A retrieval study of 423 cementless acetabular components.

    PubMed

    Swarts, Eric; Bucher, Thomas A; Phillips, Michael; Yap, Francis H X

    2015-04-01

    The effect of factors such as design, alloy and coating type on bony or fibrous tissue ingrowth was evaluated in a study of 423 retrieved cementless acetabular shells representing 16 shell designs. Small-beaded (250μm) porous coatings, either with or without hydroxyapatite (HA) coatings, proved to be the superior porous surface for bone ingrowth. Small-beaded shells that were Duofix coated had predominantly fibrous tissue ingrowth. In addition to bead size, alloy type and surface type have significant effect on bone ingrowth. In contrast, there is no significant association between bone ingrowth and time in situ, with most bone ingrowth occurring early. Although roughened, press-fit shells have acceptable clinical and Registry data, they showed some of the lowest ingrowth/ongrowth scores of all the shells tested. PMID:25515944

  17. Revision total hip replacement using the cement-in-cement technique for the acetabular component: technique and results for 60 hips.

    PubMed

    Brogan, K; Charity, J; Sheeraz, A; Whitehouse, S L; Timperley, A J; Howell, J R; Hubble, M J W

    2012-11-01

    The technique of femoral cement-in-cement revision is well established, but there are no previous series reporting its use on the acetabular side at the time of revision total hip replacement. We describe the technique and report the outcome of 60 consecutive acetabular cement-in-cement revisions in 59 patients at a mean follow-up of 8.5 years (5 to 12). All had a radiologically and clinically well-fixed acetabular cement mantle at the time of revision. During the follow-up 29 patients died, but no hips were lost to follow-up. The two most common indications for acetabular revision were recurrent dislocation (46, 77%) and to complement femoral revision (12, 20%). Of the 60 hips, there were two cases of aseptic loosening of the acetabular component (3.3%) requiring re-revision. No other hip was clinically or radiologically loose (96.7%) at the latest follow-up. One hip was re-revised for infection, four for recurrent dislocation and one for disarticulation of a constrained component. At five years the Kaplan-Meier survival rate was 100% for aseptic loosening and 92.2% (95% CI 84.8 to 99.6), with revision for any cause as the endpoint. These results support the use of cement-in-cement revision on the acetabular side in appropriate cases. Theoretical advantages include preservation of bone stock, reduced operating time, reduced risk of complications and durable fixation. PMID:23109626

  18. Observations on the initial stability of acetabular components in total hip arthroplasty. An experimental study.

    PubMed

    Pitto, R P; Sterzl, M; Hohmann, D

    1996-01-01

    It was the purpose of the study to investigate the initial stability, with or without screws, of 3 acetabular components with press-fit anchoring, by measuring bone-prosthesis micromovements during the application of physiological loading on the hip simulated in the laboratory. The prostheses, already used clinically, were characterized by different shapes and coatings. For the purposes of the study a total of 30 acetabula were used in 10 human pelves in polyurethane and 5 human pelves preserved at -20 degrees. The pelves were assembled on a hydraulic bench test with a steel jig that could be oriented, and they were cemented with polymethylmethacrylate. Three electromagnetic transducers with sensitivity of up to 1 micron (+ 500 microns) were used to measure the micromovements between the prosthesis and the acetabular rim in its three anatomical quadrants. Bone-prosthesis micromovements were recorded during 5 consecutive load tests, from 0 to 2.39 kN (244 kg). Experimental studies have shown that bone-prosthesis micromovement that exceeds 150 microns obstructs bone integration. The most significant micromovement was observed for all of the prostheses, without accessory screws, in the iliac quadrant, but only the hemispherical one with a semi-smooth surface in zirconium oxide surpassed the threshold of 150 microns. Prostheses with a porous surface demonstrated good stability (102 +/- 33 microns and 94 +/- 36 microns, respectively). None of the prostheses demonstrated micromovement exceeding 90 microns in the area corresponding to the pubis and the ischium. The use of 2 accessory screws sensitively increased the stability of all of the prostheses on the ilium, reducing the average micromovement by 40 microns. Reduction of micromovement was less on the pubis and on the ischium. PMID:8968114

  19. Measurement of lateral acetabular coverage: a comparison between CT and plain radiography

    PubMed Central

    Chadayammuri, Vivek; Garabekyan, Tigran; Jesse, Mary-Kristen; Pascual-Garrido, Cecilia; Strickland, Colin; Milligan, Kenneth; Mei-Dan, Omer

    2015-01-01

    We prospectively evaluated the degree of absolute agreement between measurements of lateral center-edge angle (LCEA) on plain radiography (XR) and computed tomography (CT) in a consecutive cohort of 205 patients (410 hips) undergoing hip arthroscopy. Preoperative measurements of the LCEA were performed bilaterally utilizing standardized anteroposterior radiographs and coronal reformatted CT scans. Demographic variables including age, gender, height, weight, BMI and clinical diagnosis were recorded for all patients. Overall, measured values of the LCEA were 2.1° larger on CT compared with XR (32.9° versus 30.8°, P < 0.001). Subgroup analysis revealed the highest mean difference in hips with acetabular dysplasia and concomitant cam-type femoroacetabular impingement (FAI) [mean difference (CT–XR) 5.5°, 95% confidence interval (CI) 3.7°–7.3°, P = 0.011], followed by hips with isolated acetabular dysplasia (mean difference [CT–XR] 4.9°, 95% CI 2.7°–7.0°, P < 0.001). In contrast, 119 (29.0%) of the hips demonstrated larger measurements of the LCEA on 25 XR relative to CT. Of these hips, 20 (16.8%) had pincer-FAI and 25 had cam-FAI (21.0%), representing a significantly higher proportion compared with all other clinical subgroups (P = 0.045 and 0.036, respectively). Our study demonstrates measured values of the LCEA are consistently inflated on CT relative to XR for a wide variety of hip pathologies, highlighting the need for standardization and validation of CT-based measurements to improve the quality of clinical decision making. Level of Evidence: Diagnostic Level II. PMID:27011864

  20. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.

    PubMed

    McKellop, H; Shen, F W; DiMaio, W; Lancaster, J G

    1999-12-01

    Crosslinking of ultrahigh molecular weight polyethylene has been shown to markedly improve its wear resistance in clinical studies and laboratory tests using hip joint simulators. However, because most of the laboratory studies have been done under clean conditions using prosthesis-quality, highly polished counterfaces, there is concern regarding how well an intentionally crosslinked polyethylene acetabular cup will resist abrasion by a femoral ball that has been damaged by third-body abrasion in vivo. To investigate this, conventional and radiation crosslinked-remelted acetabular cups of ultra-high molecular weight polyethylene were tested in a hip joint simulator bearing against smooth femoral balls and against balls with moderate and severe roughening. Cups were tested with and without aging to accelerate any oxidative degradation. The crosslinked cups were produced by exposing extruded GUR 4150 bar stock of ultrahigh molecular weight polyethylene to 5 Mrad gamma radiation under a partial vacuum and then the bars were remelted to extinguish residual free radicals. Artificial aging at 70 degrees C under 5 atm oxygen for 14 days induced negligible oxidation in the crosslinked and remelted material. Against smooth balls, the wear of the crosslinked cups, with or without aging, averaged approximately 15% of that of the conventional cups. Against the moderately rough balls, the wear rate of the conventional cups was unchanged, whereas the wear rate increased slightly for the nonaged and aged crosslinked cups, but was still only 26% and 20% of that of the conventional cups, respectively. Against extremely rough balls, the mean wear rates increased markedly for each material such that during the final 1 million cycle interval, the average wear rates of the nonaged and the aged crosslinked cups were 72% and 47% of that of the conventional cups, respectively. That is, the crosslinked polyethylene showed substantially better wear resistance than conventional polyethylene

  1. Patient-specific Analysis of Cartilage and Labrum Mechanics in Human Hips with Acetabular Dysplasia

    PubMed Central

    Henak, Corinne R; Abraham, Christine L; Anderson, Andrew E; Maas, Steve A; Ellis, Benjamin J; Peters, Christopher L; Weiss, Jeffrey A

    2014-01-01

    BACKGROUND Acetabular dysplasia is a major predisposing factor for development of hip osteoarthritis, and may result from alterations to chondrolabral loading. Subject-specific finite element (FE) modeling can be used to evaluate chondrolabral mechanics in the dysplastic hip, thereby providing insight into mechanics that precede osteoarthritis. OBJECTIVE To evaluate chondrolabral contact mechanics and congruency in dysplastic hips and normal hips using a validated approach to subject-specific FE modeling. METHODS FE models of ten subjects with normal acetabula and ten subjects with dysplasia were constructed using a previously validated protocol. Labrum load support, and labrum and acetabular cartilage contact stress and contact area were compared between groups. Local congruency was determined at the articular surface for two simulated activities. RESULTS The labrum in dysplastic hips supported 2.8 to 4.0 times more of the load transferred across the joint than in normal hips. Dysplastic hips did not have significantly different congruency in the primary load-bearing regions than normal hips, but were less congruent in some unloaded regions. Normal hips had larger cartilage contact stress than dysplastic hips in the few regions that had significant differences. CONCLUSIONS The labrum in dysplastic hips has a far more significant role in hip mechanics than it does in normal hips. The dysplastic hip is neither less congruent than the normal hip, nor subjected to elevated cartilage contact stresses. This study supports the concept of an outside-in pathogenesis of osteoarthritis in dysplastic hips and that the labrum in dysplastic hips should be preserved during surgery. PMID:24269633

  2. The Incidence of Acetabular Osteolysis in Young Patients With Conventional versus Highly Crosslinked Polyethylene

    PubMed Central

    Mall, Nathan A.; Nunley, Ryan M.; Zhu, Jin Jun; Maloney, William J.; Barrack, Robert L.

    2010-01-01

    Background Osteolysis is a major mode of hip implant failure. Previous literature has focused on the amount of polyethylene wear comparing highly crosslinked polyethylene (HXPLE) with conventional liners but has not clarified the relative incidence of osteolysis with these two liners. Questions/purposes We determined (1) the incidence of osteolysis in HXLPE versus conventional polyethylene (CPE), (2) the ability to detect and evaluate the size of lytic lesions using radiographs compared with CT scans, (3) head penetration in hips without and with lysis, and (4) determined whether acetabular position, head size, and UCLA activity score contributed to lysis. Methods We compared head penetration and osteolysis on plain radiographs and presence and volume of osteolysis on CT scans in 48 patients with HXLPE (mean, 46.5 years) and 50 patients with CPE (mean, 43.2 years). The minimum followup was 5 years (average, 7.2 years; range, 5.1–10.9 years), Results Osteolysis was apparent on CT in a larger number of patients with CPE liners than HXLPE liners: 12 of 50 (24%) versus one of 48 (2%), respectively. We found no correlation between head penetration and volume of osteolytic lesions. Head penetration was greater in patients with osteolysis. Smaller head sizes were associated with greater wear and those with osteolysis had smaller head sizes; however, there was no difference in acetabular component position or UCLA activity in those with lysis compared with those without. Conclusions HXLPE diminished the incidence of osteolysis, but the lack of correlation between penetration and volume of osteolysis suggests other factors other than wear contribute to the development of osteolysis. Level of Evidence Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence. PMID:20824407

  3. Fracture Management

    MedlinePlus

    ... to hold the fracture in the correct position. • Fiberglass casting is lighter and stronger and the exterior ... with your physician if this occurs. • When a fiberglass cast is used in conjunction with a GORE- ...

  4. Management of distal humerus fractures.

    PubMed

    McCarty, L Pearce; Ring, David; Jupiter, Jesse B

    2005-09-01

    Fractures of the distal humerus are complex injuries that can be effectively treated with open reduction and internal fixation (ORiF). Exposure of a complex intra-articular fracture may best be achieved through a posterior approach with osteotomy of the olecranon process. The ulnar nerve must be identified and protected, the articular surface must be reduced anatomically, and rigid fixation must be applied to both the medial and lateral columns of the distal humerus. Range of motion should be initiated as soon as possible postoperatively. Complications such as ulnar neuropathy, elbow stiffness, heterotopic ossification, and nonunion should be treated aggressively. Total elbow arthroplasty represents an effective option for fractures that cannot be treated with ORIF. PMID:16250484

  5. Hexapod External Fixation of Tibia Fractures in Children.

    PubMed

    Iobst, Christopher A

    2016-06-01

    Most tibia fractures in children can be treated nonoperatively. For fractures that do require surgery, however, the most common methods of management include plating or flexible nail insertion. Some fracture patterns, such as periphyseal fractures, fractures with bone and/or soft tissue loss, or fractures with delayed presentation, are not easily amenable to these techniques. Hexapod external fixators are especially helpful in these difficult cases. The purpose of this review is to discuss the principles of performing hexapod circular external fixation applied to pediatric tibia fractures. Some of the additional capabilities of the hexapod external fixator will also be highlighted. PMID:27078228

  6. Acetabular revision with impaction bone grafting and a cemented polyethylene acetabular component: comparison of the Kaplan-Meier analysis to the competing risk analysis in 62 revisions with 25 to 30 years follow-up.

    PubMed

    Te Stroet, M A J; Keurentjes, J C; Rijnen, W H C; Gardeniers, J W M; Verdonschot, N; Slooff, T J J H; Schreurs, B W

    2015-10-01

    We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). We performed Kaplan-Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint 're-revision for any reason' was 58.0% (95% confidence interval (CI) 38 to 73) and for 're-revision for aseptic loosening' 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years. PMID:26430007

  7. Gravity-Driven Hydraulic Fractures

    NASA Astrophysics Data System (ADS)

    Germanovich, L. N.; Garagash, D.; Murdoch, L. C.; Robinowitz, M.

    2014-12-01

    This study is motived by a new method for disposing of nuclear waste by injecting it as a dense slurry into a hydraulic fracture that grows downward to great enough depth to permanently isolate the waste. Disposing of nuclear waste using gravity-driven hydraulic fractures is mechanically similar to the upward growth of dikes filled with low density magma. A fundamental question in both applications is how the injected fluid controls the propagation dynamics and fracture geometry (depth and breadth) in three dimensions. Analog experiments in gelatin [e.g., Heimpel and Olson, 1994; Taisne and Tait, 2009] show that fracture breadth (the short horizontal dimension) remains nearly stationary when the process in the fracture "head" (where breadth is controlled) is dominated by solid toughness, whereas viscous fluid dissipation is dominant in the fracture tail. We model propagation of the resulting gravity-driven (buoyant or sinking), finger-like fracture of stationary breadth with slowly varying opening along the crack length. The elastic response to fluid loading in a horizontal cross-section is local and can be treated similar to the classical Perkins-Kern-Nordgren (PKN) model of hydraulic fracturing. The propagation condition for a finger-like crack is based on balancing the global energy release rate due to a unit crack extension with the rock fracture toughness. It allows us to relate the net fluid pressure at the tip to the fracture breadth and rock toughness. Unlike the PKN fracture, where breadth is known a priori, the final breadth of a finger-like fracture is a result of processes in the fracture head. Because the head is much more open than the tail, viscous pressure drop in the head can be neglected leading to a 3D analog of Weertman's hydrostatic pulse. This requires relaxing the local elasticity assumption of the PKN model in the fracture head. As a result, we resolve the breadth, and then match the viscosity-dominated tail with the 3-D, toughness

  8. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses.

    PubMed

    Mak, Mathew; Jin, Zhongmin; Fisher, John; Stewart, Todd D

    2011-01-01

    The purpose of the study was to investigate the contact stresses in 3 different acetabular cup rim designs (new, worn, chamfer) during edge loading, after microseparation of ceramic on ceramic hip prostheses. A 3-dimensional finite element analysis was conducted for a 28-mm diameter alumina ceramic bearing with a radial clearance of 40 μm using a normal load of 2500 N under edge loading. At a separation distance of 250 μm, the maximum tensile stress in the "new" design was of similar magnitude to the flexural strength of the alumina material that supports the localized breakdown (stripe wear) of the acetabular cup surface observed clinically. Introducing a 2.5-mm radius chamfer should reduce the maximum tensile stress in the region of 60%. PMID:20149581

  9. A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

    PubMed

    Clarke, S G; Phillips, A T M; Bull, A M J; Cobb, J P

    2012-06-01

    The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study. PMID:22513086

  10. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  11. Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim

    PubMed Central

    Bonneau, Noémie; Bouhallier, July; Baylac, Michel; Tardieu, Christine; Gagey, Olivier

    2012-01-01

    Understanding the three-dimensional orientation of the coxo-femoral joint remains a challenge as an accurate three-dimensional orientation ensure an efficient bipedal gait and posture. The quantification of the orientation of the acetabulum can be performed using the three-dimensional axis perpendicular to the plane that passes along the edge of the acetabular rim. However, the acetabular rim is not regular as an important indentation in the anterior rim was observed. An innovative cadaver study of the labrum was developed to shed light on the proper quantification of the three-dimensional orientation of the acetabulum. Dissections on 17 non-embalmed corpses were performed. Our results suggest that the acetabular rim is better represented by an anterior plane and a posterior plane rather than a single plane along the entire rim as it is currently assumed. The development of the socket from the Y-shaped cartilage was suggested to explain the different orientations in these anterior and posterior planes. The labrum forms a plane that takes an orientation in between the anterior and posterior parts of the acetabular rim, filling up inequalities of the bony rim. The vectors VL, VA2 and VP, representing the three-dimensional orientation of the labrum, the anterior rim and the posterior rim, are situated in a unique plane that appears biomechanically dependent. The three-dimensional orientation of the acetabulum is a fundamental parameter to understand the hip joint mechanism. Important applications for hip surgery and rehabilitation, as well as for physical anthropology, were discussed. PMID:22360458

  12. Novel methods to evaluate fracture risk models

    PubMed Central

    Donaldson, M.G.; Cawthon, P. M.; Schousboe, J.T.; Ensrud, K.E.; Lui, L.Y.; Cauley, J.A.; Hillier, T.A.; Taylor, B.C.; Hochberg, M.C.; Bauer, D.C.; Cummings, S.R.

    2013-01-01

    Fracture prediction models help identify individuals at high risk who may benefit from treatment. Area Under the Curve (AUC) is used to compare prediction models. However, the AUC has limitations and may miss important differences between models. Novel reclassification methods quantify how accurately models classify patients who benefit from treatment and the proportion of patients above/below treatment thresholds. We applied two reclassification methods, using the NOF treatment thresholds, to compare two risk models: femoral neck BMD and age (“simple model”) and FRAX (”FRAX model”). The Pepe method classifies based on case/non-case status and examines the proportion of each above and below thresholds. The Cook method examines fracture rates above and below thresholds. We applied these to the Study of Osteoporotic Fractures. There were 6036 (1037 fractures) and 6232 (389 fractures) participants with complete data for major osteoporotic and hip fracture respectively. Both models for major osteoporotic fracture (0.68 vs. 0.69) and hip fracture (0.75 vs. 0.76) had similar AUCs. In contrast, using reclassification methods, each model classified a substantial number of women differently. Using the Pepe method, the FRAX model (vs. simple model), missed treating 70 (7%) cases of major osteoporotic fracture but avoided treating 285 (6%) non-cases. For hip fracture, the FRAX model missed treating 31 (8%) cases but avoided treating 1026 (18%) non-cases. The Cook method (both models, both fracture outcomes) had similar fracture rates above/below the treatment thresholds. Compared with the AUC, new methods provide more detailed information about how models classify patients. PMID:21351143

  13. Fractures of distal radius: an overview.

    PubMed

    Meena, Sanjay; Sharma, Pankaj; Sambharia, Abhishek Kumar; Dawar, Ashok

    2014-01-01

    Fractures of distal radius account for up to 20% of all fractures treated in emergency department. Initial assessment includes a history of mechanism of injury, associated injury and appropriate radiological evaluation. Treatment options include conservative management, internal fixation with pins, bridging and non-bridging external fixation, dorsal or volar plating with/without arthroscopy assistance. However, many questions regarding these fractures remain unanswered and good prospective randomized trials are needed. PMID:25657938

  14. Fractures of Distal Radius: An Overview

    PubMed Central

    Meena, Sanjay; Sharma, Pankaj; Sambharia, Abhishek Kumar; Dawar, Ashok

    2014-01-01

    Fractures of distal radius account for up to 20% of all fractures treated in emergency department. Initial assessment includes a history of mechanism of injury, associated injury and appropriate radiological evaluation. Treatment options include conservative management, internal fixation with pins, bridging and non-bridging external fixation, dorsal or volar plating with/without arthroscopy assistance. However, many questions regarding these fractures remain unanswered and good prospective randomized trials are needed. PMID:25657938

  15. Intramedullary nailing of tibial shaft fractures.

    PubMed

    Kyrö, A; Lamppu, M; Böstman, O

    1995-01-01

    Sixty-four displaced tibial shaft fractures were treated using intramedullary nailing, either primarily or after an attempt at conservative treatment, which consisted of closed reduction under anaesthesia and immobilisation in a long-leg plaster cast. There were 37 closed and 27 open fractures. Three patients had a fracture of both tibiae. The median time period from the intramedullary nailing of the closed solitary fractures to union was about the same after primary nailing as after delayed nailing. Although the fractures were different in these groups, it is possible that the time spent in conservative treatment before intramedullary nailing brings no additional benefits. The incidence of deep infection in open fractures after primary nailing was 1/16. The fractures, in which an acceptable position could not be maintained using conservative methods, were mainly spiral in configuration and located in the distal third or at the junction of the middle and distal thirds of the tibia. PMID:7645911

  16. Upward and inward displacements of the acetabular component increase stress on femoral head in single endoprothesis models

    PubMed Central

    Zhang, Zhiqi; Kang, Yan; Chen, Yi; Liao, Weiming

    2009-01-01

    The centre of rotation of the hip can be displaced in hip dysplasia and revision arthroplasty. This study examined the effect of artificial femoral head load after acetabular component displacement in total hip arthroplasty. Sixteen total hip arthroplasty models of human cadaver specimens were reconstructed, and under different acetabular component position, the load around the femoral head was evaluated by strain gages. The results showed that the load was higher in the same specimens when the cup was moved 2 mm inward or upward, especially after the cup was moved more than 6 mm, and the load had an increasing effect in the inward group. In the upward group, an increasing effect happened at 8 mm upward displacement, but the stress value decreased from 4 mm to 6 mm upward displacement. In the same moving distance, the stress of inward displacement is obviously higher than upward displacement. Altogether, the results suggested that for both inward displacement and upward displacement of the acetabular cup, the load around the femoral head increased gradually, while the distance of the inward displacement and the superior displacement was increased. The greater the displacement, the bigger the loading contact stress. The upward displacement caused less stress change on the femoral head. The stress of the 6 mm upward position was lower than nearby positions; perhaps this site represented a stress buffering zone. PMID:19424694

  17. Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results

    PubMed Central

    Sandri, Andrea

    2014-01-01

    Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC). Twenty-nine patients (32 implants) died for unrelated causes without additional surgery. Sixty-five hips were available for clinical and radiographic assessment at an average follow-up of 14.6 years (range, 10.0 to 18.9 years). There were 16 male and 49 female patients, aged from 29 to 83 (median, 60 years), with Paprosky IIIA (27 cases) and IIIB (38 cases) acetabular bone defects. Nine cages required rerevision because of infection (3), aseptic loosening (5), and flange breakage (1). The average Harris hip score improved from 33.1 points preoperatively to 75.6 points at follow-up (P < 0.001). Radiographically, graft incorporation and cage stability were detected in 48 and 52 hips, respectively. The cumulative survival rates at 18.9 years with removal for any reason or X-ray migration of the cage and aseptic or radiographic loosening as the end points were 80.0% and 84.6%, respectively. The use of the Burch-Schneider APC and massive allografts is an effective technique for the reconstructive treatment of extensive acetabular bone loss with long-lasting survival. PMID:24967339

  18. Pediatric Thighbone (Femur) Fracture

    MedlinePlus

    ... fractures in infants under 1 year old is child abuse. Child abuse is also a leading cause of thighbone fracture ... contact sports • Being in a motor vehicle accident • Child abuse Types of Femur Fractures (Classification) Femur fractures vary ...

  19. Hydraulic fracturing-1

    SciTech Connect

    Not Available

    1990-01-01

    This book contains papers on hydraulic fracturing. Topics covered include: An overview of recent advances in hydraulic fracturing technology; Containment of massive hydraulic fracture; and Fracturing with a high-strength proppant.

  20. Is It a Simple Stress Fracture or Bisphosphonate-related Atypical Fracture?

    PubMed

    Kang, Soo Yong; Baek, Ji-Hoon; Kang, Bun Jung; Kim, Min Kyu; Lee, Han-Jun

    2012-11-01

    A number of reports regarding atypical fractures of the femur have raised questions concerning the possible correlation between long-term bisphosphonate treatment and the occurrence of insufficiency fractures in the proximal femur. However, clinically, it is often confused whether is it a fatigue fracture because of implant induced stress concentration or a bisphosphonate-related atypical fracture, especially in a patient with a subtrochanteric fracture who receive bisphosphonate therapy after open reduction and internal fixation, such as dynamic hip screw (DHS) fixation for previous ipsilateral femoral neck or intertrochanteric fracture. The authors experienced a case of a progressive femoral insufficiency fracture in a woman who had been on Fosamax (Alendronic acid with Vitamin D; Merck & Co. Inc, NJ, USA) therapy for four years after ipsilateral femoral neck fracture treated with a two hole DHS system. Despite a high suspicion of an insufficiency femoral subtrochanteric fracture by bone scan, the occult fracture progressed to a displaced femoral subtrochanteric fracture one year after. The fracture site was fixed with a 6 hole DHS plate, and six months after reoperation the patient had no symptoms and the fracture site had united without any complication. PMID:24524043

  1. HUMERAL SHAFT FRACTURES

    PubMed Central

    Benegas, Eduardo; Ferreira Neto, Arnaldo Amado; Neto, Raul Bolliger; Santis Prada, Flavia de; Malavolta, Eduardo Angeli; Marchitto, Gustavo Oliveira

    2015-01-01

    Humeral shaft fractures (HSFs) represent 3% of the fractures of the locomotor apparatus, and the middle third of the shaft is the section most affected. In the majority of cases, it is treated using nonsurgical methods, but surgical indications in HSF cases are increasingly being adopted. The diversity of opinions makes it difficult to reach a consensus regarding the types of osteosynthesis, surgical technique and quantity and quality of synthesis materials that should be used. It would appear that specialists are far from reaching a consensus regarding the best method for surgical treatment of HSFs. We believe that less invasive methods, which favor relative stability, are the most appropriate methods, since the most feared complications are less frequent. PMID:27019833

  2. [Scaphoid fracture in motocross riders].

    PubMed

    Knobloch, K; Krämer, R; Redeker, J; Spies, M; Vogt, P M

    2009-12-01

    Motocross racing is a demanding motorcycling discipline with significant physiological and psychological demands. Upper extremity injuries are frequently encountered. Interestingly, motocross riders present with a significantly stronger left arm, even if the left hand is not dominant. This difference is attributed to the use of the clutch lever with the left hand, which is more frequent in motocross than in Enduro or desert rally. The wrist has been reported to be involved especially among motocross racers in contrast to road racing. Besides wrist fractures, scaphoid fractures have been previously without a detailed analysis of the injury mechanism. We report on three patients suffering scaphoid fractures caused by extreme hyperextension of the wrist during landing after a motocross jump. Two patients presented late three months following the initial trauma (both Herbert type C fractures), while one motocross athlete with a B 2-type scaphoid fracture was admitted to wrist surgery within a week. The B 2-type fracture was treated with open reduction and Herbert-screw fixation, while the C-type fractures were treated by Herbert-screw fixation in addition to a cortico-cancellous bone graft. Within ten weeks after the surgery the patients were back in sport at their given preoperative level. Hyperextension rather than wrist flexion appears as the predominant mechanism of wrist injuries in motocross riders. A more axial impact on the wrist is more likely to produce a radial fracture during the landing phase. Preventive strategies are internal muscular wrist stabilisation using eccentric training and external stabilisation by rigid gloves allowing only limited hyperextension. PMID:20108186

  3. Management of Typical and Atypical Hangman's Fractures.

    PubMed

    Al-Mahfoudh, Rafid; Beagrie, Christopher; Woolley, Ele; Zakaria, Rasheed; Radon, Mark; Clark, Simon; Pillay, Robin; Wilby, Martin

    2016-05-01

    Study Design Retrospective study of a prospectively maintained database. Objective Our aim was to retrospectively review management and outcomes of patients with low-grade hangman's fractures, specifically looking at differences in outcomes between collars and halo immobilization. We also studied fracture patterns and their treatment outcomes. Methods Forty-one patients with hangman's fractures were identified from 105 patients with axis fractures between 2007 and 2013. Typical hangman's fractures were defined as traumatic spondylolisthesis of the axis causing a bilateral pars interarticularis fracture. Fractures involving the posterior cortex of C2 on one or both sides or an asymmetrical pattern were defined as atypical. Results There were 41 patients with a mean age of 59 years, with 13 (31.7%) typical and 28 (68.2%) atypical fractures. There were 22 (53.6%) type 1 fractures, 7 (41.4%) type 2 fractures, and 2 (4.9%) type 2a fractures in this series. Cervical collars were used to manage 11 patients (27% of all patients with hangman's fractures) and halo orthosis was used in 27 (65.8%). Three (7.3%) patients underwent surgical fixation of the fracture. Bony union was achieved in all patients on radiologic follow-up. Permanent neurologic deficit occurred in one patient due to associated injuries. Neck pain and stiffness were reported more commonly in the atypical group, but this finding was not statistically significant. Conclusions The majority of hangman type fractures can be treated nonoperatively. We found no difference in outcomes between a rigid collar or halo immobilization for treatment of low-grade fractures. Radiologic follow-up is essential to identify cases of nonunion. PMID:27099816

  4. Management of Typical and Atypical Hangman's Fractures

    PubMed Central

    Al-Mahfoudh, Rafid; Beagrie, Christopher; Woolley, Ele; Zakaria, Rasheed; Radon, Mark; Clark, Simon; Pillay, Robin; Wilby, Martin

    2015-01-01

    Study Design Retrospective study of a prospectively maintained database. Objective Our aim was to retrospectively review management and outcomes of patients with low-grade hangman's fractures, specifically looking at differences in outcomes between collars and halo immobilization. We also studied fracture patterns and their treatment outcomes. Methods Forty-one patients with hangman's fractures were identified from 105 patients with axis fractures between 2007 and 2013. Typical hangman's fractures were defined as traumatic spondylolisthesis of the axis causing a bilateral pars interarticularis fracture. Fractures involving the posterior cortex of C2 on one or both sides or an asymmetrical pattern were defined as atypical. Results There were 41 patients with a mean age of 59 years, with 13 (31.7%) typical and 28 (68.2%) atypical fractures. There were 22 (53.6%) type 1 fractures, 7 (41.4%) type 2 fractures, and 2 (4.9%) type 2a fractures in this series. Cervical collars were used to manage 11 patients (27% of all patients with hangman's fractures) and halo orthosis was used in 27 (65.8%). Three (7.3%) patients underwent surgical fixation of the fracture. Bony union was achieved in all patients on radiologic follow-up. Permanent neurologic deficit occurred in one patient due to associated injuries. Neck pain and stiffness were reported more commonly in the atypical group, but this finding was not statistically significant. Conclusions The majority of hangman type fractures can be treated nonoperatively. We found no difference in outcomes between a rigid collar or halo immobilization for treatment of low-grade fractures. Radiologic follow-up is essential to identify cases of nonunion. PMID:27099816

  5. Dilemmas in imaging for peri-acetabular osteotomy: the influence of patient position and imaging technique on the radiological features of hip dysplasia.

    PubMed

    Kosuge, D; Cordier, T; Solomon, L B; Howie, D W

    2014-09-01

    Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam. PMID:25183583

  6. [Update on current care guidelines: Hip fracture].

    PubMed

    2011-01-01

    In Finland approximately 7,000 hip fractures occurred annually during 1996-2008. Risk of hip fracture can be diminished through efforts to prevent falls and osteoporosis. A hip fracture is treated operatively, with the aim of early mobilisation and full weight bearing. Postoperative care and rehabilitation requires multidisciplinary and multifaceted management, focusing on improvement of the patient's physical condition, appropriate pain management, the prevention of delirium and other possible complications. Rehabilitation should be centralised in specialised rehabilitation centres for the elderly. Secondary prevention of future fractures should include management of osteoporosis and fall prevention. PMID:21888050

  7. Surgical treatment of orbital floor fractures.

    PubMed

    Rankow, R M; Mignogna, F V

    1975-01-01

    Ninety patients with orbital floor fractures were treated by the Otolaryngology Service of the Columbia-Presbyterian Medical Center. Of these 90 patients, 58 were classified as coexisting and 32 as isolated. All fractures with clinical symptoms and demonstrable x-ray evidence should be explored. Despite negative findings by routine techniques, laminography may confirm fractures in all clinically suspicious cases. In this series, 100% of the patients explored had definitive fractures. A direct infraorbital approach adequately exposes the floor of the orbit. An effective and cosmetic subtarsal incision was utilized. Implants were employed when the floor could not be anatomically reapproximated or the periorbita was destroyed. PMID:1119982

  8. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results.

    PubMed

    Ybinger, Thomas; Kumpan, W; Hoffart, H E; Muschalik, B; Bullmann, W; Zweymüller, K

    2007-09-01

    The postoperative position of the acetabular component is key for the outcome of total hip arthroplasty. Various aids have been developed to support the surgeon during implant placement. In a prospective study involving 4 centers, the computer-recorded cup alignment of 37 hip systems at the end of navigation-assisted surgery was compared with the cup angles measured on postoperative computerized tomograms. This comparison showed an average difference of 3.5 degrees (SD, 4.4 degrees ) for inclination and 6.5 degrees (SD, 7.3 degrees ) for anteversion angles. The differences in inclination correlated with the thickness of the soft tissue overlying the anterior superior iliac spine (r = 0.44; P = .007), whereas the differences in anteversion showed a correlation with the thickness of the soft tissue overlying the pubic tubercles (r = 0.52; P = .001). In centers experienced in the use of navigational tools, deviations were smaller than in units with little experience in their use. PMID:17826270

  9. Arthroscopic Bone Grafting of Deep Acetabular Cysts Using a Curved Delivery Device

    PubMed Central

    Garabekyan, Tigran; Chadayammuri, Vivek; Pascual-Garrido, Cecilia; Mei-Dan, Omer

    2016-01-01

    Acetabular intraosseous cysts are frequently encountered in patients with dysplasia or femoroacetabular impingement. Small cysts are typically addressed by removing the cyst lining and stimulating healing via microfracture or abrasion chondroplasty. In contrast, larger cysts involving 1-3 cm3 frequently require additional fortification with bone graft material to facilitate osseous ingrowth and cyst healing. Previous arthroscopic reports have described the use of rim trimming to access the extra-articular side of the cyst, with subsequent use of straight metal cannulas for delivery of bone graft material. The downsides of this technique include the requirement for rim trimming, which may be ill advised in patients with normal coverage or dysplasia, as well as the creation of a second breach in the cyst wall, precluding pressurization of the bone graft material. We describe an arthroscopic technique using a curved delivery device allowing for deeper penetration into the cyst cavity through the articular side and greater delivery of bone graft material. PMID:27073770

  10. Radiographic evaluation of HDPE cemented and cementless Lord and An.C.A. screwed acetabular models.

    PubMed

    Toni, A; Sudanese, A; Viceconti, M; Montina, P P; Ciaroni, D; Calista, F; Terzi, S; Giunti, A

    1992-01-01

    A total of 187 alumina screwed porous-ceramic coated sockets (An.C.A.), 48 screwed smooth-surfaced Lord sockets, and 251 cemented polyethylene sockets were radiographically evaluated at an average follow-up of 30, 51 and 96 months respectively. After 6 years the Lord prostheses revealed a 38% incidence of loosening, similar to that observed for cemented sockets 10-12 years after surgery. The An.C.A. prostheses revealed radiographic loosening equal to 12% (6 cases) in the first 50 implants, and only 0.7% in the remaining 137 cases: overall, the An.C.A. acetabular prosthesis revealed an index of radiographic loosening equal to 3.3% (7/187). To guarantee "osteointegration" of the porous coating of An.C.A. sockets optimal stability must be obtained when the prosthesis is screwed in. Because the mid-term follow-up for this clinical experience is relatively short (30 months), an opinion on the reliability of the screwed "porous" sockets must await confirmation. PMID:1297574

  11. Retrieval analysis of a failed TriboFit polycarbonate urethane acetabular buffer.

    PubMed

    Biant, Leela C; Gascoyne, Trevor C; Bohm, Eric R; Moran, Matthew

    2016-03-01

    The purpose of this research was to determine the failure mechanisms and damage features of a TriboFit acetabular buffer implanted directly against a native, prepared acetabulum which was revised after 11months. Retrieval analyses were carried out via light microscopy, gravimetric wear assessment, and observer scoring of visible damage features on the buffer. The volume of material abraded from the backside of the buffer was estimated via three-dimensional reconstruction using a laser scanner. Scanning electron microscopy was used to confirm damage features and mechanisms. Severe abrasion to the backside of the buffer was the primary damage feature, while stippling damage was seen on the articular surface of the buffer. Material loss due to backside abrasion was approximated to be between 0.13360.085 g (gravimetric analyses) and 0.19360.053 g (three-dimensional reconstruction). Implantation of the TriboFit buffer against the patient's native acetabulum without a metal backing allowed for significant movement of the buffer against the bone, resulting in the abrasion seen on this implant. The stippling damage on the articular surface indicates an adhesive wear mechanism which exacerbates movement of the buffer against the acetabulum, thereby increasing backside abrasion. PMID:26833696

  12. The effect of femoro-acetabular impingement on the kinematics and kinetics of the hip joint.

    PubMed

    Alshameeri, Zeiad; Khanduja, Vikas

    2014-08-01

    Gait analysis is an objective tool that has been used to assess and monitor treatment for many musculoskeletal conditions. Recently, it has been used to assess the impact of femoro-acetabular impingement (FAI) on the hip and lower limb movements. There have been a fairly limited number of studies published so far reporting unexpected and inconsistent results, which calls for more research to be conducted in this arena. In the light of the limited data available, it has been challenging to reconcile the contradictions in some of these results, and therefore no coherent conclusions could be drawn. In this short article, we attempt to explain some of the abnormal kinematic and kinetic patterns associated with FAI by highlighting similarities between the gait seen in early osteoarthritis (OA) and that of FAI. We also propose an approach for future research in this field and emphasise the importance of quantifying early OA in FAI based on magnetic resonance imaging (MRI) scans and the amount of chondral damage seen during open or arthroscopic surgery. PMID:24687267

  13. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation.

    PubMed

    Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien

    2014-09-01

    Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. PMID:25080896

  14. The Relationship of Acetabular Dysplasia and Femoroacetabular Impingement to Hip Osteoarthritis: A Focused Review

    PubMed Central

    Royer, Nathaniel K.

    2012-01-01

    Hip osteoarthritis (OA) leads to significant functional limitations and economic burden. If modifiable risk factors for hip OA are identified, it may be possible to implement preventative measures. Bony abnormalities associated with acetabular dysplasia (AD) and femoroacetabular impingement (FAI) have been recently implicated as risk factors for hip osteoarthritis (OA). The purpose of this focused review is to summarize the available evidence describing the relationship between bony abnormalities and hip OA. A librarian-assisted database search using PubMed, Embase and Central was performed. Relevant articles were identified and assessed for inclusion criteria. The authors reviewed cohort and case control studies that reported on the association between abnormal hip morphology and hip OA. The available literature suggests that an association exists between bony abnormalities found in AD and FAI and hip OA and preliminary evidence suggests that AD is a risk factor for OA, however these conclusions are based on limited evidence. Prospective, longitudinal studies are needed to confirm the causal relationship between abnormal hip morphology and the future development of hip OA. PMID:22108232

  15. Effects of acetabular resurfacing component material and fixation on the strain distribution in the pelvis.

    PubMed

    Thompson, M S; Northmore-Ball, M D; Tanner, K E

    2002-01-01

    A 3D finite element (FE) model of an implanted pelvis was developed as part of a project investigating an all-polymer hip resurfacing design. The model was used to compare this novel design with a metal-on-metal design in current use and a metal-on-polymer design typical of early resurfacing implants. The model included forces representing the actions of 22 muscles as well as variable cancellous bone stiffness and variable cortical shell thickness. The hip joint reaction force was applied via contact modelled between the femoral and acetabular components of the resurfacing prosthesis. Five load cases representing time points through the gait cycle were analysed. The effect of varying fixation conditions was also investigated. The highest cancellous bone strain levels were found at mid-stance, not heel-strike. Remote from the acetabulum there was little effect of prosthesis material and fixation upon the von Mises stresses and maximum principal strains. Implant material appeared to have little effect upon cancellous bone strain failure with both bended and unbonded bone-implant interfaces. The unbonded implants increased stresses in the subchondral bone at the centre of the acetabulum and increased cancellous bone loading, resembling behaviour obtained previously for the intact acetabulum. PMID:12206520

  16. Explicit finite element modelling of the impaction of metal press-fit acetabular components.

    PubMed

    Hothi, H S; Busfield, J J C; Shelton, J C

    2011-03-01

    Metal press-fit cups and shells are widely used in hip resurfacing and total hip replacement procedures. These acetabular components are inserted into a reamed acetabula cavity by either impacting their inner polar surface (shells) or outer rim (cups). Two-dimensional explicit dynamics axisymmetric finite element models were developed to simulate these impaction methods. Greater impact velocities were needed to insert the components when the interference fit was increased; a minimum velocity of 2 m/s was required to fully seat a component with a 2 mm interference between the bone and outer diameter. Changing the component material from cobalt-chromium to titanium alloy resulted in a reduction in the number of impacts on the pole to seat it from 14 to nine. Of greatest significance, it was found that locking a rigid cap to the cup or shell rim resulted in up to nine fewer impactions being necessary to seat it than impacting directly on the polar surface or using a cap free from the rim of the component, as is the case with many commercial resurfacing cup impaction devices currently used. This is important to impactor design and could make insertion easier and also reduce acetabula bone damage. PMID:21485331

  17. The capsular ligaments provide more hip rotational restraint than the acetabular labrum and the ligamentum teres

    PubMed Central

    van Arkel, R. J.; Amis, A. A.; Cobb, J. P.; Jeffers, J. R. T.

    2015-01-01

    In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty. Cite this article: Bone Joint J 2015; 97-B:484–91. PMID:25820886

  18. Tranexamic acid reduces the blood loss and blood transfusion requirements following peri-acetabular osteotomy.

    PubMed

    Wassilew, G I; Perka, C; Janz, V; Krämer, M; Renner, L

    2015-12-01

    We have investigated the effect of using tranexamic acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative blood loss and blood transfusion requirements. In addition we analysed whether the use of TXA was associated with an increased risk of venous thromboembolism (VTE) following this procedure. A consecutive series of 96 PAOs, performed by a single surgeon, were reviewed. A total of 48 patients received TXA and 48 did not. The TXA group received a continuous infusion of TXA at a rate of 10 mg/kg/h. The primary outcome measure was the requirement for blood transfusion. Secondary outcomes included total blood loss, the decrease in the level of haemoglobin in the blood, the length of hospital stay, and the complications of this treatment. The mean rate of transfusion was significantly lower in the TXA group (62.5% vs 12.5%, p < 0.001). The mean blood loss was also significantly reduced in the TXA group (1.9 L (standard deviation (SD) 0.9) vs 1.5 L (SD 0.7), p < 0.01). No post-operative episodes of VTE were identified in either group. The use of TXA reduced the blood loss and the rate of transfusion after PAO significantly, without adverse effects such as an increased rate of VTE. PMID:26637672

  19. Ex vivo estimation of cementless acetabular cup stability using an impact hammer.

    PubMed

    Michel, Adrien; Bosc, Romain; Sailhan, Frédéric; Vayron, Romain; Haiat, Guillaume

    2016-02-01

    Obtaining primary stability of acetabular cup (AC) implants is one of the main objectives of press-fit procedures used for cementless hip arthroplasty. The aim of this study is to investigate whether the AC implant primary stability can be evaluated using the signals obtained with an impact hammer. A hammer equipped with a force sensor was used to impact the AC implant in 20 bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the inserted AC implant was impacted four times with a maximum force comprised between 2500 and 4500 N. An indicator I was determined based on the partial impulse estimation and the pull-out force was measured. The implant stability and the value of the indicator I reached a maximum value for an interference fit equal to 1 mm for 18 out of 20 samples. When pooling all samples and all configurations, the implant stability and I were significantly correlated (R(2) = 0.83). The AC implant primary stability can be assessed through the analysis of the impact force signals obtained using an impact hammer. Based on these ex vivo results, a medical device could be developed to provide a decision support system to the orthopedic surgeons. PMID:26671784

  20. Risk factors associated with facial fractures.

    PubMed

    Batista, Anne Margareth; Ferreira, Fernanda de Oliveira; Marques, Leandro Silva; Ramos-Jorge, Maria Letícia; Ferreira, Meire Coelho

    2012-01-01

    The aim of the present study was to identify risk factors for facial fractures in patients treated in the emergency department of a hospital. The medical charts of 1121 patients treated in an emergency ward over a three-year period were analyzed. The independent variables were gender, age, place of residence (urban or rural area) and type of accident. The dependent variables were fractured mandible, zygoma, maxilla, nasal bone and more than one fractured facial bone. Statistical analysis was performed using the chi-square test (a < 0.05), univariate and multivariate Poisson distributions and the logistic regression analysis (p < 0.20). Maxillofacial trauma was recorded in 790 charts (70.5%), with 393 (35.1%) charts reporting facial fractures. Motorcycle accidents were found to be the main risk factor for mandibular fractures (PR = 1.576, CI = 1.402-1.772) and simultaneous fractures of more than one facial bone (OR = 4.625, CI = 1.888-11.329) as well as the only risk factor for maxillary bone fractures (OR = 11.032, CI = 5.294-22.989). Fractures of the zygomatic and nasal bones were mainly associated with accidents involving animals (PR = 1.206, CI = 1.104-1.317) and sports (OR = 8.710, CI = 4.006-18.936), respectively. The determinant for the majority of facial fractures was motorcycle accidents, followed by accidents involving animals and sports. PMID:22473346

  1. Treatment of complex elbow fracture-dislocations.

    PubMed

    Chan, Kevin; King, Graham J W; Faber, Kenneth J

    2016-06-01

    Successful management of complex elbow fracture-dislocations requires, in part, recognition of the overall injury pattern, which can aid in the identification of concomitant bony and soft tissue injuries. Trans-olecranon fracture-dislocations are best treated surgically with stable anatomic restoration of the trochlear notch. Terrible triad elbow injuries are believed to be caused by a valgus posterolateral force. Although select terrible triad injuries can be managed non-operatively, the majority of injuries are treated with stable surgical repair to allow early elbow motion. Unlike terrible triads, varus posteromedial forces are theorized to cause anteromedial coronoid fractures. These are usually associated with LCL disruptions, but do not have concomitant MCL or radial head injuries. A subset of anteromedial coronoid fractures can also be managed non-operatively. Internal fixation is recommended for injuries associated with large fracture fragments or elbow instability preventing early motion. PMID:26984334

  2. Management of Complications of Distal Radius Fractures

    PubMed Central

    Chung, Kevin C.; Mathews, Alexandra L.

    2015-01-01

    Synopsis Treating a fracture of the distal radius may require the surgeon to make a difficult decision between surgical treatment and nonsurgical management. The use of surgical fixation has recently increased owing to complications associated with conservative treatment. However, conservative action may be necessary depending on certain patient factors. The treating surgeon must be aware of the possible complications associated with distal radius fracture treatments to prevent their occurrence. Prevention can be achieved with a proper understanding of the mechanism of these complications. This article discusses the most recent evidence on how to manage and prevent complications following a fracture of the distal radius. PMID:25934197

  3. Combined Tibial Tubercle Avulsion Fracture and Patellar Avulsion Fracture: An Unusual Variant in an Adolescent Patient.

    PubMed

    Stepanovich, Matthew T; Slakey, Joseph B

    2016-01-01

    Traumatic extensor dysfunction of the knee in children is a rare injury, with the majority resulting from tibial tubercle avulsion fracture or patellar sleeve fracture. We report a rare case of combined patellar avulsion fracture and tibial tubercle fracture. With open anatomic reduction, both injuries were successfully treated. While many variations of tibial tubercle fracture have been reported, the authors believe this to be the first report in the English-language literature of this particular combined injury to the knee extensor mechanism in an adolescent. Advanced imaging with computed tomography provided vital information to aid with operative planning, especially since the majority of the unossified tubercle was not seen on plain radiographs, and all fracture fragments were originally believed to be from the tibial tubercle. Computed tomography distinguished the patellar fracture from the tibial tubercle fragments, verifying preoperatively the complexity of the injury. PMID:26761925

  4. [Sarmiento's method of conservative treatment of leg fractures].

    PubMed

    Dewijze, M; Pe, M; Tondeur, G

    1985-01-01

    The authors present a prospective series of 32 fractures of the tibia, treated by Sarmiento's technique. Consolidation of the fracture has been obtained in 3 to 4 months. Five open tibia fractures healed in 4 months. Functional recovery is complete in 90% of the cases. Two failures needed late surgical treatment (one centro-medullary nailing and one plate-fixation). These fractures are studied in detail. PMID:3984632

  5. [Malunited juvenile fractures in the foot region].

    PubMed

    Zwipp, H; Ranft, T

    1991-11-01

    Between 1971 and 1990 we treated 121 juvenile patients up to 14 years of age with fractures of the ankle joint and foot in the department of trauma surgery at Hannover Medical School. A total of 128 fractures were treated in these patients, excluding toe fractures. The distribution of fractures as referred to the anatomical-functional planes was as follows: Tibia-talar joint 69; talus 8; calcaneus 6; Chopart joint 5; Lisfranc joint 4 and metatarsal area 36. Clinical and radiological follow-up investigations were possible a mean of 8.7 years post trauma for all talar and calcaneal fractures, for 7 out of 9 Chopart/Lisfranc injuries and for 7 out of 35 of metatarsal fractures. In the case of talus fractures our results suggest that it is to restore the original length of the talus bone (medial column); this is important to prevent collapse of the longitudinal arch with subsequent early arthritis. The rare cases of sustained intraarticular damage to calcaneal fractures should be treated as in adults, i.e. by open, anatomical reconstruction. In children, Chopart/Lisfranc 2 fracture dislocations only occur if high-energy trauma is present (runover trauma in 4 out of 9 cases). Optimal treatment again is comparable to that in adults: open, anatomical reduction with Kirschner-wires followed by temporary, tibio-tarsal transfixation; this is important since no compensatory mechanisms develop if a subluxation is present after reduction. Metatarsal fractures often occur along the first and fifth rays and have a good prognosis. Conservative treatment is justified, since, according to our results, even in intraarticular fractures of the metatarsal head good remodeling to fragments occurs. PMID:1684652

  6. Revision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study

    PubMed Central

    Jeong, Min; Kim, Hyung-Joo; Lim, Seung-Jae; Moon, Young-Wan

    2016-01-01

    Purpose The purpose of this study is to report the short-term outcomes of revision total hip arthroplasty (THA) using tantalum augments in patients with severe acetabular bone defects. Materials and Methods We retrospectively analyzed 15 revision THAs performed in 15 patients using tantalum augments between June 2010 and December 2013. Acetabular bone defects were Paprosky type IIIA in 7 hips, type IIIB in 7, and type IV in 1. The causes of revision surgery were aseptic loosening in 12 hips and deep infection in 3. Revisions were first in 1 hip, second in 3, and third in 11. Six patients were male and 9 female with a mean age of 59 years (range, 48-75 years). Mean follow-up was 29 months (range, 24-48 months). Results Mean Harris hip score was improved from 34 points (range, 12-54 points) preoperatively to 84 points (range, 38-90 points) at final follow-up. On the final follow-up radiographs, there were 12 hips (80.0%) with stable fixation of the acetabular cup, 2 (13.3%) with secondary stability after mild acetabular protrusion, and 1 (6.7%) with radiolucency around the acetabular cup without mechanical symptoms. Complications included one patient with acute hematogenous infection managed by surgical debridement and long-term antibiotic therapy. There were no cases with nerve palsy or dislocation during the follow-up period. Conclusion The present study showed satisfactory clinical and radiographic outcomes of revision THA using tantalum augments due to severe acetabular bone defects of Paprosky type III or IV at a minimum follow-up of 2 years. PMID:27536651

  7. Wear of the polyethylene liner-metallic shell interface in modular acetabular components. An in vitro analysis.

    PubMed

    Lieberman, J R; Kay, R M; Hamlet, W P; Park, S H; Kabo, J M

    1996-08-01

    The purpose of this study was to determine the effect of compression cycles and wear patterns on the polyethylene liner-metallic shell interface in modular acetabular components. Articular frictional torque was also measured. Modular acetabular components from five manufacturers were tested. The polyethylene liners were sputter coated with gold on the convex surface to enhance the visualization of wear and deformation patterns. Each component was cycled for 10 million cycles in a hydraulic fatigue testing machine. Frictional torque was measured prior to the start of the cyclic loading and in increments of 2 million cycles. Frictional torque was significantly lower in the design with an enhanced polyethylene liner. Abrasion of the gold from the convex surface of polyethylene liners varied from 2 to 23% between designs. Extrusion of the polyethylene into the screw holes in the metallic shells was universal. Three modes of damage (burnishing, punch-out, and gouging) were identified on the convex surface of the polyethylene liner. Abrasion of the gold from the convex surface of the polyethylene varied greatly between designs. This is indicative of relative motion between the polyethylene liner and the metallic shell. This motion must be minimized to limit the generation of wear debris from the convex surface of the polyethylene. Several aspects of modular acetabular component design could be implemented to potentially reduce wear, including limiting the number of holes available for screw placement, smoothing out the edges of the screw holes to avoid punch-out, and avoiding supplemental fixation of the liner unless it is essential to prevent motion between the liner and the metallic shell. PMID:8872582

  8. Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum

    PubMed Central

    Henak, C.R.; Abraham, C.L.; Peters, C.L.; Sanders, R.K.; Weiss, J.A.; Anderson, A.E.

    2014-01-01

    AIM To develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum. MATERIALS AND METHODS Ninety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured. RESULTS Using the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (~5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98–6.7 mm (2.46 ± 1.16 mm). CONCLUSIONS When applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required. PMID:25070373

  9. Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components.

    PubMed

    Takahashi, Yasuhito; Tateiwa, Toshiyuki; Shishido, Takaaki; Masaoka, Toshinori; Kubo, Kosuke; Yamamoto, Kengo

    2016-10-01

    The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs). PMID:27454526