Science.gov

Sample records for acetabular fractures treated

  1. Management of neglected acetabular fractures.

    PubMed

    Veerappa, L A; Tripathy, S K; Sen, R K

    2015-08-01

    Management of neglected acetabular fractures is a difficult task. Osteosynthesis in such cases may not be an ideal solution because of the femoral head damage due to pressure by the fractured acetabular edge, avascular necrosis, difficulty in mobilizing the fragments due to callus formation, difficulty in indirect reduction of the fracture fragments and macerated acetabular fragments all contributing to inadequate fracture reduction. Majority of such fractures are now treated with total hip replacement. While treating such fractures with THR, problems associated with neglected acetabular fractures such as fracture non-union, hip dislocation, protrusio, cavitary bone defect or peripheral bone defect must be considered. 3D computed tomography scan provides a clear view about the acetabular and periacetabular bony anatomy. Impaction grafting and antiprotrusio cage or ring with a cemented acetabular cup can address most of the hip protrusio and cavitary bone defects. Segmental bone defect needs cortical strut-bone graft fixation and subsequent implantation of a cemented or uncemented acetabular cup implantation. Fracture non-union needs approximate reduction and fixation with plates followed by bone grafting and implantation of an acetabular cup. Despite these efforts, the outcome of THR in neglected acetabular fracture is considerable worse than after conventional hip replacement.

  2. Fix and replace; an emerging paradigm for treating acetabular fractures

    PubMed Central

    Murphy, Colin G.; Carrothers, Andrew D.

    2016-01-01

    Summary Although technically challenging even for the experienced surgeon, simultaneous open reduction and internal fixation (ORIF) of acetabular fracture and total hip replacement (THR) have some potential advantages over the more traditional treatment options in specific patient subgroups; theoretically allowing immediate weight bearing and faster rehabilitation, reducing the cost of inpatient stay, and reducing the risks of early and late local complications associated with standard treatment for this type of injury. We review the evolution of the indications and techniques, outline the surgical challenges, and discuss implant options and outcomes for this treatment paradigm. PMID:28228787

  3. Fix and replace: An emerging paradigm for treating acetabular fractures in older patients

    PubMed Central

    Tissingh, Elizabeth K; Johnson, Abigail; Queally, Joseph M; Carrothers, Andrew D

    2017-01-01

    Acetabular fractures in older patients are challenging to manage. The “fix and replace” construct may present a new paradigm for the management of these injuries. We present the current challenge of acetabular fractures in older patients. We present this in the context of the current literature. This invited editorial presents early results from our centre and the ongoing challenges are discussed. PMID:28361014

  4. Central acetabular fracture with dislocation treated by minimally invasive plate osteosynthesis.

    PubMed

    2015-06-01

    Central acetabular fractures with dislocation are usually the result of high-energy trauma, resulting in joint incongruity, and are frequently associated with other injuries. Open reduction and internal fixation has been the standard treatment for acetabular fractures, but it is associated with extensive surgical trauma, and complications such as haematoma formation, iatrogenic nerve injury, and heterotopic ossification. We present the case of a 63-year-old female who sustained a central acetabular fracture of the hip with dislocation as a result of an automobile collision. Closed reduction of the dislocation was performed, and the fracture was managed by minimally invasive plate osteosynthesis using a specially prepared plate. At 01 year postoperatively, radiographs showed the fracture to have been well-healed with good congruity of the joint. However, heterotopic ossification of the joint was noted. The technique allowed reduction of the fracture with minimal surgical trauma.

  5. Arthroscopic Reduction and Transportal Screw Fixation of Acetabular Posterior Wall Fracture: Technical Note

    PubMed Central

    Park, Jin young; Kim, Che Keun; Huh, Soon Ho; Kim, Se Jin; Jung, Bo Hyun

    2016-01-01

    Acetabular fractures can be treated with variable method. In this study, acetabular posterior wall fracture was treated with arthroscopic reduction and fixation using cannulated screw. The patient recovered immediately and had a satisfactory outcome. In some case of acetabular fracture could be good indication with additional advantages of joint debridement and loose body removal. So, we report our case with technical note. PMID:27536654

  6. Controversies in Treatment of Acetabular Fracture

    PubMed Central

    Grubor, Predrag; Krupic, Ferid; Biscevic, Mirza; Grubor, Milan

    2015-01-01

    Introduction: Acetabular fractures treatment represents a great controversy, challenge and dilemma for an orthopedic surgeon. Aim: The aim of the paper was to present the results of treatment of 96 acetabular fractures in the Clinic of Traumatology Banja Luka, in the period from 2003 to 2013, as well as to raise awareness regarding the controversy in the methods of choice in treating acetabulum fractures. Material and methods: The series consists of 96 patients, 82 males and 14 females, average age 40.5 years. Traffic trauma was the cause of fractures in 79 patients (85%), and in 17 patients (15%) fractures occurred due to falls from height. Polytrauma was present in 31 patients (32%). According to the classification of Judet and Letournel, representation of acetabular fractures was as follows: posterior wall in 32 patients, posterior column in 28, anterior wall in 4, anterior column in 2, transverse fractures in 8, posterior wall and posterior column in 10, anterior and posterior wall in 6, both- column in 4 and transversal fracture and posterior wall in 2 patients. 14 patients were treated with traction, that is, 6 patients with femoral traction and 8 patients with both lateral and femoral traction. 82 patients (86.4%) were surgically treated. Kocher-Langenbeck approach was applied in the treatment of 78 patients. In two patients from the Kocher-Langenbeck’s approach, the Ollier’s approach had to be applied as well. Two acetabular were primarily treated with Ollier’s approach. Extended Smith- Peterson’s approach was applied 4 times, and Emile Letournel’s (ilioinguinal) approach 14 times. Results: Functional outcome (after follow-up of 18 months), according to the Harris hip score of surgical treatment in 82 patients, was as follows: good 46 (56%), satisfactory 32 (39%) and poor 4 (5%). Results of acetabulum fractures treated with traction were: good 8 (57%), satisfactory 4 (28%) and poor 2 (15%). According to the Brook’s classification of heterotopic

  7. Acetabular Fractures in the Elderly: Treatment Recommendations

    PubMed Central

    Pagenkopf, Eric; Grose, Andrew; Partal, George

    2006-01-01

    Acetabular fractures in the elderly population are marked by a high degree of variability in terms of patient and fracture characteristics. Successful outcomes depend on application of highly individualized management principles by experienced teams. Reviewed are indications and outcomes associated with various management options, including closed treatment, open reduction internal fixation, and acute or staged total hip arthroplasty. Proper initial management choices are critical, as early failures and subsequent salvage surgery can be accompanied by significant morbidity. Clinical results after ORIF closely follow the quality of articular reduction and the ability to maintain a congruent reduction of the hip joint. Fracture characteristics predictive of anatomic articular reduction should be treated with ORIF. Fracture characteristics predictive of early post-traumatic arthritis should be treated with simultaneous ORIF and THA. Presented is one referral institution’s treatment algorithm and management approach. PMID:18751831

  8. Management of an Open Acetabular Fracture in a Skeletally Immature Patient

    PubMed Central

    Clutter, Sarah Y; Morgan, Steven J; Erickson, Mark; Smith, Wade R; Stahel, Philip F

    2007-01-01

    Background: Open acetabular fractures in children are rare, but potentially devastating injuries. Secondary to the low incidence, there is an apparent lack of reports on appropriate management strategies for open pediatric acetabular fractures in the literature. Methods: Description of a case study. Results: A 3 years and ten months-old girl was ejected as a passenger from an all terrain vehicle. She sustained a displaced, grade IIIA open left anterior column acetabular fracture. The injury was treated by extending the open wound to a formal first window of the ilioinguinal approach. After surgical debridement, the anterior column was reduced anatomically and fixed by two lag screws which avoided the tri-radiate cartilage. A vaginal laceration was debrided and repaired. The patient was treated in a spica cast without weight bearing on the left lower extremity for 8 weeks. No perioperative complications occurred. The acetabular fracture healed in an anatomic position within 8 weeks. To avoid premature closure of the tri-radiate cartilage, the patient underwent a physeal bar resection at one year after injury. At two-year follow up, she was walking and running without pain and had a free range of motion of her left hip. Conclusions: Operative management should represent the therapy of choice for open, displaced pediatric acetabular fractures. After fracture healing, a scheduled physeal bar resection may be required for injuries which involve the tri-radiate cartilage. PMID:19461903

  9. [Application of three-dimensional printing personalized acetabular wing-plate in treatment of complex acetabular fractures via lateral-rectus approach].

    PubMed

    Mai, J G; Gu, C; Lin, X Z; Li, T; Huang, W Q; Wang, H; Tan, X Y; Lin, H; Wang, Y M; Yang, Y Q; Jin, D D; Fan, S C

    2017-03-01

    Objective: To investigate reduction and fixation of complex acetabular fractures using three-dimensional (3D) printing technique and personalized acetabular wing-plate via lateral-rectus approach. Methods: From March to July 2016, 8 patients with complex acetabular fractures were surgically managed through 3D printing personalized acetabular wing-plate via lateral-rectus approach at Department of Orthopedics, the Third Affiliated Hospital of Southern Medical University. There were 4 male patients and 4 female patients, with an average age of 57 years (ranging from 31 to 76 years). According to Letournel-Judet classification, there were 2 anterior+ posterior hemitransverse fractures and 6 both-column fractures, without posterior wall fracture or contralateral pelvic fracture. The CT data files of acetabular fracture were imported into the computer and 3D printing technique was used to print the fractures models after reduction by digital orthopedic technique. The acetabular wing-plate was designed and printed with titanium. All fractures were treated via the lateral-rectus approach in a horizontal position after general anesthesia. The anterior column and the quadrilateral surface fractures were fixed by 3D printing personalized acetabular wing-plate, and the posterior column fractures were reduction and fixed by antegrade lag screws under direct vision. Results: All the 8 cases underwent the operation successfully. Postoperative X-ray and CT examination showed excellent or good reduction of anterior and posterior column, without any operation complications. Only 1 case with 75 years old was found screw loosening in the pubic bone with osteoporosis after 1 month's follow-up, who didn't accept any treatment because the patient didn't feel discomfort. According to the Matta radiological evaluation, the reduction of the acetabular fracture was rated as excellent in 3 cases, good in 4 cases and fair in 1 case. All patients were followed up for 3 to 6 months and all

  10. A Novel Approach for Treatment of Acetabular Fractures

    PubMed Central

    Xue, Zichao; Qin, Hui; Ding, Haoliang; An, Zhiquan

    2016-01-01

    Background There is no single approach that provides adequate exposure for treatment of all types of acetabular fractures. We describe our experience with an easier, relatively less invasive pubic symphysis approach (PSA) for the treatment of acetabular fractures. Material/Methods Between March 2011 and March 2012, fifteen patients with acetabular fracture underwent surgery using the PSA technique. Fracture reduction and treatment outcomes were assessed by clinical and radiological examination. Operation time, intraoperative blood loss and postoperative complications were documented. Results Mean operative time was 222±78 minutes. Average blood loss was 993±361 mL. Anatomical reduction was achieved in all patients. Minimum follow-up period was 31 months. Postoperative hypoesthesia in the area of innervation of the lateral femoral cutaneous nerve was reported in one patient, with spontaneous recovery at one month after surgery. No complications were reported during the follow-up period. At the most recent follow up, clinical outcomes were graded as “excellent” in six patients, “good” in eight patients and “fair” in one patient based on the modified Merle d’Aubigné-Postel score. Conclusions PSA appears to be a timesaving and safe approach for treatment of acetabular fractures that affords good visual access and allows for excellent fracture reduction. Our preliminary results revealed a much lower incidence of complications than traditional approaches, suggesting PSA is an alternative for treatment of acetabular fractures. PMID:27734825

  11. Predictors of poor outcome after both column acetabular fractures: a 30-year retrospective cohort study

    PubMed Central

    2013-01-01

    Background and Purpose Acetabular fractures are often combined with associated injuries to the hip joint. Some of these associated injuries seem to be responsible for poor long-term results and these injuries seem to affect the outcome independent of the quality of the acetabular reduction. The aim of our study was to analyze the outcome of both column acetabular fractures and the influence of osseous cofactors such as initial fracture displacement, hip dislocation, femoral head lesions and injuries of the acetabular joint surface. Methods A retrospective cohort study in patients with both column acetabular fractures treated over a 30 year period was performed. Patients with a follow-up of more than two years were invited for a clinical and radiological examination. Displacement was analyzed on initial and postoperative radiographs. Contusion and impaction of the femoral head was grouped. Injuries of the acetabular joint surface consisting of impaction, contusion and comminution were recorded. The Merle d’Aubigné Score was documented and radiographs were analysed for arthritis (Helfet classification), femoral head avascular necrosis (Ficat/Arlet classification) and heterotopic ossifications (Brooker classification). Results 115 patients were included in the follow up examination. Anatomic reduction (malreduction ≤ 1mm) was associated with a significantly better clinical outcome than nonanatomical reduction (p = 0.001). Initial displacement of more than 10mm (p = 0.031) and initial intraarticular fragments (p = 0.041) were associated with worse outcome. Other associated injuries, such as the presence of a femoral head dislocation, femoral head injuries and injuries to the acetabular joint surface showed no significant difference in outcome individually, but in fractures with more than two associated local injuries the risk for joint degeneration was significant higher (p < 0.001) than in cases with less than two of them. In the subgroup of

  12. Acetabular Fractures in the Elderly: Midterm Outcomes of Column Stabilisation and Primary Arthroplasty

    PubMed Central

    Ortega-Briones, A.; Smith, S.

    2017-01-01

    Background. Interest in arthroplasty techniques for periarticular or intra-articular fractures in the elderly/osteoporotic patient continues to rise, including for geriatric acetabular fractures. In line with this, many acetabular fracture surgeons are now undertaking acute total hip arthroplasty in elderly/osteoporotic patients. Little is known however of the outcomes of this procedure, beyond the first year after surgery. Questions/Purposes. We determined the clinical outcomes of a series of elderly osteoporotic patients (mean age at surgery 77.4 years) treated for acetabular fractures with column fixation and simultaneous total hip arthroplasty, at a mean of 49 months after surgery. Methods. 24 patients (25 hips) were reviewed at a mean of 49 months after surgery. The surgical technique employed has previously been described. Radiographs were obtained, and clinical outcomes were assessed using Harris Hip Scores and the Merle d'Aubigné score. Results. 14 hips were available for assessment (9 deceased, 2 lost to follow-up). No patient suffered any complications beyond the perioperative period, no acetabular components were loose clinically or on latest radiographs, and the mean Harris Hip Score was 92. All but one patient scored good or excellent on the Merle d'Aubigné score. Conclusions. Column fixation and simultaneous total hip arthroplasty are a viable option for complex geriatric acetabular fractures, with encouraging midterm results. We conclude that THR is a viable long-term solution in this situation provided that the acetabular columns are stabilised prior to implantation, but more research is needed to aid in overall management decision making. PMID:28194414

  13. Tension band stabilisation of acetabular physeal fractures in four kittens.

    PubMed

    Langley-Hobbs, S J; Sissener, T R; Shales, C J

    2007-06-01

    The surgical repair of acetabular physeal fractures in four kittens using a screw and tension band technique is reported. This was an appropriate method for restoring articular congruency and improving pelvic alignment. All cases had an excellent outcome and full limb use following fracture repair. In kittens younger than 12 weeks, there is a possibility of premature fusion of the acetabular bone resulting in development of a deformed, shallow acetabulum and hip subluxation. However, surgery is still justified when there is pelvic canal narrowing to decrease the risk of future defecatory problems. Early implant removal in such young kittens may decrease the severity of deformity caused by premature physeal closure. In kittens of 16 weeks or older, the prognosis is good for normal acetabular development and implant removal is not necessary.

  14. Development of site-specific locking plates for acetabular fractures.

    PubMed

    Xu, Meng; Zhang, Li-Hai; Zhang, Ying-Ze; He, Chun-Qing; Zhang, Li-Cheng; Wang, Yan; Tang, Pei-Fu

    2013-05-01

    Site-specific locking plates have gained popularity for the treatment of fractures. However, the clinical use of a site-specific locking plate for acetabular fractures remains untested due to production limits. To design a universal site-specific locking plate for acetabular fractures, the 3-dimensional (3D) photographic records of 171 pelvises were retrospectively studied to generate a universal posterior innominate bone surface. Using 3D photographical processing software, the 3D coordinate system was reset according to bony landmarks and was scaled based on the acetabular diameter to allow a direct comparison between surfaces. The measured surface was separated into measurement units. At each measurement unit, the authors calculated the average z-axis values in all samples and obtained the 3D coordinate values of the point cloud that could be reconstructed into the universal surface. A plate was subsequently designed in 3D photographical processing software, and the orientation and distribution of locking screws was included. To manufacture a plate, the data were entered into Unigraphics NX version 6.0 software (Siemens PLM Software, Co, Ltd, Plano, Texas) and a CNC digital milling machine (FANUC Co, Ltd, Yamanashi, Japan). The resulting locking plate fit excellently with the reduced bone surface intraoperatively. Plate contouring was avoided intraoperatively. Universal 3.5-mm locking screws locked successfully into the plate, and their orientations were consistent with the design. No screw yielded to acetabular penetration. This method of designing a site-specific acetabular locking plate is practical, and the plates are suitable for clinical use. These site-specific locking plates may be an option for the treatment of acetabular fractures, particularly in elderly patients.

  15. Atypical periprosthetic acetabular fracture in long-term alendronate therapy

    PubMed Central

    Marongiu, Giuseppe; Capone, Antonio

    2016-01-01

    Summary Bisphosphonates have been commonly used in the treatment of osteoporosis, demonstrating its efficacy in fracture risk reduction. However, even if are generally safe and well tolerated, concerns have emerged about atypical fractures related to its prolonged use. Although atypical femoral fracture are more common, case reports demonstrated that even other skeletal areas can be involved by unusual pattern of fracture. We report a atypical acetabular periprosthetic fracture in a 83-year-old female patient after prolonged alendronate treatment for osteoporosis and isolated acetabular revision surgery. The patient underwent to clinical, bioumoral and radiological evaluation and all the history cases were fully reported. We believe this periprosthetic fracture, according to the available data, may have similar underlying pathology to atypical femoral fractures. Awareness of symptoms, in addition to a regular radiographic survey may facilitate early diagnosis and possible prevention of spontaneous periprosthetic fractures, in patients receiving bisphosphonate therapy beyond 5 years. The treatment of this atypical periprosthetic fracture should include both surgical than pharmacological therapy to obtained bone healing. PMID:28228784

  16. Double-crush syndrome after acetabular fractures. A sign of poor prognosis.

    PubMed

    Giannoudis, P V; Da Costa, A A; Raman, R; Mohamed, A K; Smith, R M

    2005-03-01

    Injury to the sciatic nerve is one of the more serious complications of acetabular fracture and traumatic dislocation of the hip, both in the short and long term. We have reviewed prospectively patients, treated in our unit, for acetabular fractures who had concomitant injury to the sciatic nerve, with the aim of predicting the functional outcome after these injuries. Of 136 patients who underwent stabilisation of acetabular fractures, there were 27 (19.9%) with neurological injury. At initial presentation, 13 patients had a complete foot-drop, ten had weakness of the foot and four had burning pain and altered sensation over the dorsum of the foot. Serial electromyography (EMG) studies were performed and the degree of functional recovery was monitored using the grading system of the Medical Research Council. In nine patients with a foot-drop, there was evidence of a proximal acetabular (sciatic) and a distal knee (neck of fibula) nerve lesion, the double-crush syndrome. At the final follow-up, clinical examination and EMG studies showed full recovery in five of the ten patients with initial muscle weakness, and complete resolution in all four patients with sensory symptoms (burning pain and hyperaesthesia). There was improvement of functional capacity (motor and sensory) in two patients who presented initially with complete foot-drop. In the remaining 11 with foot-drop at presentation, including all nine with the double-crush lesion, there was no improvement in function at a mean follow-up of 4.3 years.

  17. Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study

    PubMed Central

    Huang, De-Yong; Zhang, Liang; Zhou, Yi-Xin; Zhang, Chun-Yu; Xu, Hui; Huang, Yong

    2016-01-01

    Background: Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures, and good results have been reported with the use of these cups; however, the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear. This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures. Methods: A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012. Among these patients, two were lost to follow-up. Therefore, 39 patients (39 hips) were finally included in this study. The Harris hip score before and after the surgery, satisfaction level of the patients, and radiographic results were assessed. Results: The mean Harris hip score increased from 34 (range, 8–52) before surgery to 91 (range, 22–100) at the latest follow-up examination (P < 0.001). The results were excellent for 28 hips, good for six, fair for three, and poor for two. Among the 39 patients, 25 (64%) and 10 (26%) were very satisfied and somewhat satisfied, respectively. All cups were found to be fully incorporated, and no evidence of cup migration or periacetabular osteolysis was noted. Conclusions: Despite the technically demanding nature of the procedure, THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures. PMID:27064033

  18. Surgical treatment of an acetabular fracture and labral tear with suture anchors in a 10-year-old child.

    PubMed

    Mormor, Meir; Matityahu, Amir

    2009-11-01

    This article presents a case of a 10-year-old boy with a right acetabular fracture secondary to a direct blow to the pelvis and back. He sustained a right hip dislocation and transverse with posterior wall acetabular fracture with a nonconcentric hip joint after reduction. The fracture was treated with right labral and articular segment absorbable suture tie-down and relocation of the right hip into an anatomical position. At 32-month follow-up, the patient had returned to activities of daily living, he had a normal and symmetric gait pattern, and no pain on hip adduction, flexion, or internal rotation. This technique reduced the fracture and labrum, relocated the hip joint, and obviated the need for hardware removal that is typically needed in the pediatric population. This case is distinctive due to the patient's young age and treatment method, which has not been described previously for the treatment of this rare pediatric fracture.

  19. ANALYSIS OF THE SEGMENTAL IMPACTION OF FEMORAL HEAD FOLLOWING AN ACETABULAR FRACTURE SURGICALLY MANAGED

    PubMed Central

    Guimarães, Rodrigo Pereira; Kaleka, Camila Cohen; Cohen, Carina; Daniachi, Daniel; Keiske Ono, Nelson; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Riccioli, Walter

    2015-01-01

    Objective: Correlate the postoperative radiographic evaluation with variables accompanying acetabular fractures in order to determine the predictive factors for segmental impaction of femoral head. Methods: Retrospective analysis of medial files of patients submitted to open reduction surgery with internal acetabular fixation. Within approximately 35 years, 596 patients were treated for acetabular fractures; 267 were followed up for at least two years. The others were excluded either because their follow up was shorter than the minimum time, or as a result of the lack of sufficient data reported on files, or because they had been submitted to non-surgical treatment. The patients were followed up by one of three surgeons of the group using the Merle d'Aubigné and Postel clinical scales as well as radiological studies. Results: Only tow studied variables-age and amount of postoperative reductionshowed statistically significant correlation with femoral head impaction. Conclusions: The quality of reduction-anatomical or with up to 2mm residual deviation-presents a good radiographic evolution, reducing the potential for segmental impaction of the femoral head, a statistically significant finding. PMID:27004191

  20. Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China

    PubMed Central

    Liu, Xinwei; Xu, Shuogui; Su, Jiacan; Yu, Baoqing

    2009-01-01

    Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40–50°C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D’Aubigne−Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply. PMID:20012433

  1. Value of 3-D CT in classifying acetabular fractures during orthopedic residency training.

    PubMed

    Garrett, Jeffrey; Halvorson, Jason; Carroll, Eben; Webb, Lawrence X

    2012-05-01

    The complex anatomy of the pelvis and acetabulum have historically made classification and interpretation of acetabular fractures difficult for orthopedic trainees. The addition of 3-dimensional (3-D) computed tomography (CT) scan has gained popularity in preoperative planning, identification, and education of acetabular fractures given their complexity. Therefore, the authors examined the value of 3-D CT compared with conventional radiography in classifying acetabular fractures at different levels of orthopedic training. Their hypothesis was that 3-D CT would improve correct identification of acetabular fractures compared with conventional radiography.The classic Letournel fracture pattern classification system was presented in quiz format to 57 orthopedic residents and 20 fellowship-trained orthopedic traumatologists. A case consisted of (1) plain radiographs and 2-dimensional axial CT scans or (2) 3-D CT scans. All levels of training showed significant improvement in classifying acetabular fractures with 3-D vs 2-D CT, with the greatest benefit from 3-D CT found in junior residents (postgraduate years 1-3).Three-dimensional CT scans can be an effective educational tool for understanding the complex spatial anatomy of the pelvis, learning acetabular fracture patterns, and correctly applying a widely accepted fracture classification system.

  2. The Retroacetabular Angle Determines the Safe Angle for Screw Placement in Posterior Acetabular Fracture Fixation

    PubMed Central

    Tadros, Ayman M. A.; Oxland, Thomas R.; O'Brien, Peter

    2013-01-01

    Introduction. A method for the determination of safe angles for screws placed in the posterior acetabular wall based on preoperative computed tomography (CT) is described. It defines a retroacetabular angle and determines its variation in the population. Methods. The retroacetabular angle is the angle between the retroacetabular surface and the tangent to the posterior acetabular articular surface. Screws placed through the marginal posterior wall at an angle equal to the retroacetabular angle are extraarticular. Medial screws can be placed at larger angles whose difference from the retroacetabular angle is defined as the allowance angles. CT scans of all patients with acetabular fractures treated in our institute between September 2002 to July 2007 were used to measure the retroacetabular angle and tangent. Results. Two hundred thirty one patients were included. The average (range) age was 42 (15–74) years. The average (range) retroacetabular angle was 39 (30–47) degrees. The average (range) retroacetabular tangent was 36 (30–45) mm. Conclusions. Placing the screws at an average (range) angle of 39 (33–47) degrees of anterior inclination with the retroacetabular surface makes them extraarticular. Angles for medial screws are larger. Safe angles can be calculated preoperatively with a computer program. PMID:24959359

  3. Acetabular roof stress fracture: a rare cause of hip pain in children

    PubMed Central

    Jlalia, Zied; Bellil, Mehdi; Ghachem, Maher Ben

    2016-01-01

    Stress fracture of acetabular roof is an unusual cause of hip pain. It is considered as an underdiagnosed entity. People who are more susceptible to experience this fracture are athletes, soldiers and dancers. We present the case of an 11 year old girl with a roof acetabular stress fracture for which the diagnosis and follow-ups were possible by the means of MRI. The treatment was keeping the child at a complete rest. Failure to abide with this treatment can cause the stress fracture to evaluate into a complete fracture. PMID:28154643

  4. Biomechanical Analysis of the Fixation System for T-Shaped Acetabular Fracture

    PubMed Central

    Fan, Yanping; Lei, Jianyin; Zhu, Feng; Li, Zhiqiang; Chen, Weiyi; Liu, Ximing

    2015-01-01

    This study aims to evaluate the biomechanical mechanism of fixation systems in the most frequent T-shaped acetabular fracture using finite element method. The treatment of acetabular fractures was based on extensive clinical experience. Three commonly accepted rigid fixation methods (double column reconstruction plates (P × 2), anterior column plate combined with posterior column screws (P + PS), and anterior column plate combined with quadrilateral area screws (P + QS)) were chosen for evaluation. On the basis of the finite element model, the biomechanics of these fixation systems were assessed through effective stiffness levels, stress distributions, force transfers, and displacements along the fracture lines. All three fixation systems can be used to obtain effective functional outcomes. The third fixation system (P + QS) was the optimal method for T-shaped acetabular fracture. This fixation system may reduce many of the risks and limitations associated with other fixation systems. PMID:26495030

  5. A growing problem: acetabular fractures in the elderly and the combined hip procedure.

    PubMed

    Buller, Leonard T; Lawrie, Charles M; Vilella, Fernando E

    2015-04-01

    Acetabular fractures in the elderly are most frequently the result of low-energy trauma and present unique management challenges to orthopedic surgeons. Evaluation and treatment should be performed in a multidisciplinary fashion with early involvement of internal medicine subspecialists and geriatricians. Distinct fracture patterns and pre-existing osteoarthritis and osteoporosis necessitate careful preoperative planning. The role of total hip arthroplasty should also be considered when surgical treatment is indicated. The outcomes of acetabular fractures in the elderly have improved, but complications remain higher and results less satisfactory than in younger individuals. The lack of randomized controlled trials has limited the ability to establish an evidence-based treatment algorithm.

  6. Pelvic, acetabular and hip fractures: What the surgeon should expect from the radiologist.

    PubMed

    Molière, S; Dosch, J-C; Bierry, G

    2016-01-01

    Pelvic ring fractures when caused by trauma, either violent or in demineralized bone, generally consist of injuries in both the anterior (pubic symphysis and rami) and posterior (iliac wing, sacrum, sacroiliac joint) portions. Injury classifications are based on injury mechanism and pelvic stability, and are used to determine treatment. Acetabular fractures, associated or not to pelvic ring disruption, are classified on the basis of fracture line, into elementary fractures of the acetabular walls, columns and roof, and into complex fractures. Fractures of the proximal end of the femur occur often on demineralized bone following low-energy trauma. The fractures are categorized by anatomic location (neck, trochanter and subtrochanteric region) and degree of displacement. These variables determine the risk of osteonecrosis of the femoral head, which is the main complication of such fractures.

  7. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture

    PubMed Central

    2016-01-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum. PMID:27550496

  8. Fucntional and Radiological Outcome of Surgical Management of Acetabular Fractures in Tertiary Care Hospital

    PubMed Central

    Taufiq, Intikhab; Najjad, Muhammad Kazim Raheem; Khan, Naveed; Zia, Osama Bin

    2016-01-01

    Purpose Acetabular fractures are mainly caused by trauma and the incidence is rising in developing countries. Initially these fractures were managed conservatively, due to lack of specialized and dedicated acetabulum surgery centres. Our aim is to study the radiological and functional outcomes of surgical management of acetabular fractures in tertiary care hospital. Materials and Methods Total 50 patients were enrolled. The patients with acetabular fractures were enrolled between the years 2012 to 2014. Patients were evaluated clinically with Harris hip score (HHS) and radiologically with Matta outcome grading. The factors examined include age, gender, fracture pattern, time between injury and surgery, initial displacement and quality of reduction on the final outcome. Results There were 34 males and 16 females. Mean age was 44.20±11.65 years while mean duration of stay was 9.28±2.36 days. Duration of follow-up was 24 months. Most common mechanism of injury was motor vehicle accident (n=37, 74.0%). Open reduction and internal fixation of fractures were performed using reconstruction plates. Mean HHS at 24 months was 82.36±8.55. The clinical outcome was acceptable (excellent or good) in 35 (70.0%) cases and not acceptable (fair or poor) in 15 (30.0%) cases. The radiological outcome was anatomical in 39 (78.0%) cases, congruent in 5 (10.0%) cases, incongruent in 6 (12.0%) cases. Conclusion Study results indicated that mechanism of injury, time between injury and surgery, initial degree of displacement and quality of reduction had significant effect on functional as well as radiological outcome. PMID:28097111

  9. [Aseptic, simultaneous and bilateral mobilisation due to an acetabular shell fracture in a 43 year-old patient].

    PubMed

    Ceretti, M; Fanelli, M; Pappalardo, S

    2014-01-01

    The acetabular shell mobilization is the main long-term complication in total hip replacement. Metal-back fracture has also to be considered among the possible causes of shell mobilization. A case is presented of bilateral acetabular shell mobilization due to the trabecular covering de-soldering from the metal-back in a 43 year-old patient, 13-14 years after the first surgery.

  10. Clinical fracture of cross-linked UHMWPE acetabular liners.

    PubMed

    Furmanski, Jevan; Anderson, Martin; Bal, Sonny; Greenwald, A Seth; Halley, David; Penenberg, Brad; Ries, Michael; Pruitt, Lisa

    2009-10-01

    Highly cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is increasingly used as a bearing material in total hip replacements. Cross-linking of UHMWPE has been shown to increase wear resistance but decrease its fracture resistance. We analyzed the clinical fracture failure of four cross-linked UHMWPE total hip replacement components of four different designs via microscopic observation of the fracture surfaces, and found that in all cases fractures initiated at stress concentrations in an unsupported region of the component (termed the elevated rim). Finite element analyses (FEA) of each individual implant design were then conducted. Results from this analysis demonstrated that the predicted magnitude and orientation of maximum principal stress due to mechanical loading of the elevated rim was sufficient to propagate initiated fatigue cracks in each case. FEA also predicted that cracks may arrest after some amount of growth due to a steep stress gradient near the initiation site. Further, while anatomical positioning of the implant and material properties affect the risk of fracture, we examined whether these failures are strongly related to the notched elevated rim design feature that is common to the four failed cases presented here. We believe that cross-linked UHMWPE remains an excellent bearing material for total hip replacements but that designs employing this material should mitigate stress concentrations or other design features that increase the risk of fracture.

  11. A feasibility study into the use of three-dimensional printer modelling in acetabular fracture surgery.

    PubMed

    Yu, A W; Duncan, J M; Daurka, J S; Lewis, A; Cobb, J

    2015-01-01

    There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient's unique anatomy can only lead to improved outcomes.

  12. An Effective and Feasible Method, “Hammering Technique,” for Percutaneous Fixation of Anterior Column Acetabular Fracture

    PubMed Central

    Zhang, Lihai; Zhang, Wei; Li, Tongtong; Li, Jiantao; Chen, Hua

    2016-01-01

    Objective. The objective of this study was to evaluate the effectiveness and advantages of percutaneous fixation of anterior column acetabular fracture with “hammering technique.” Materials and Methods. We retrospectively reviewed 16 patients with percutaneous fixation of anterior column acetabular fracture with “hammering technique.” There were 11 males and 5 females with an average age of 38.88 years (range: 24–54 years) in our study. Our study included 7 nondisplaced fractures, 6 mild displaced fractures (<2 mm), and 5 displaced fractures (>2 mm). The mean time from injury to surgery was 4.5 days (range: 2–7 days). Results. The average of operation time was 27.56 minutes (range: 15–45 minutes), and the mean blood loss was 55.28 mL (range: 15–100 mL). The mean fluoroscopic time was 54.78 seconds (range: 40–77 seconds). The first pass of the guide wire was acceptable without cortical perforation or intra-articular perforation in 88.89% (16/18) of the procedures, and the second attempt was in 11.11% (2/18). Conclusion. Our study suggested that percutaneous fixation of anterior column acetabular fracture with “hammering technique” acquired satisfying surgical and clinical outcomes. It may be an alternative satisfying treatment for percutaneous fixation of anterior column acetabular fracture by 2D fluoroscopy using a C-arm with less fluoroscopic time. PMID:27493962

  13. Prophylactic radiotherapy against heterotopic ossification following internal fixation of acetabular fractures: a comparative estimate of risk

    PubMed Central

    Nasr, P; Yip, G; Scaife, J E; House, T; Thomas, S J; Harris, F; Owen, P J; Hull, P

    2014-01-01

    Objective: Radiotherapy (RT) is effective in preventing heterotopic ossification (HO) around acetabular fractures requiring surgical reconstruction. We audited outcomes and estimated risks from RT prophylaxis, and alternatives of indometacin or no prophylaxis. Methods: 34 patients underwent reconstruction of acetabular fractures through a posterior approach, followed by a 8-Gy single fraction. The mean age was 44 years. The mean time from surgery to RT was 1.1 days. The major RT risk is radiation-induced fatal cancer. The International Commission on Radiological Protection (ICRP) method was used to estimate risk, and compared with a method (Trott and Kemprad) specifically for estimating RT risk for benign disease. These were compared with risks associated with indometacin and no prophylaxis. Results: 28 patients (82%) developed no HO; 6 developed Brooker Class I; and none developed Class II–IV HO. The ICRP method suggests a risk of fatal cancer in the range of 1 in 1000 to 1 in 10,000; the Trott and Kemprad method suggests 1 in 3000. For younger patients, this may rise to 1 in 2000; and for elderly patients, it may fall to 1 in 6000. The risk of death from gastric bleeding or perforation from indometacin is 1 in 180 to 1 in 900 in older patients. Without prophylaxis risk of death from reoperation to remove HO is 1 in 4000 to 1 in 30,000. Conclusion: These results are encouraging, consistent with much larger series and endorse our multidisciplinary management. Risk estimates can be used in discussion with patients. Advances in knowledge: The risk from RT prophylaxis is small, it is safer than indometacin and substantially overlaps with the range for no prophylaxis. PMID:25089852

  14. The incidence of stress fracture following peri-acetabular osteotomy: an under-reported complication.

    PubMed

    Malviya, A; Dandachli, W; Beech, Z; Bankes, M J; Witt, J D

    2015-01-01

    Stress fractures occurring in the pubis and ischium after peri-acetabular osteotomy (PAO) are not well recognised, with a reported incidence of 2% to 3%. The purpose of this study was to analyse the incidence of stress fracture after Bernese PAO under the care of two high-volume surgeons. The study included 359 patients (48 men, 311 women) operated on at a mean age of 31.1 years (15 to 56), with a mean follow-up of 26 months (6 to 64). Complete follow-up radiographs were available for 348 patients, 64 of whom (18.4%) developed a stress fracture of the inferior pubic ramus, which was noted at a mean of 9.1 weeks (5 to 55) after surgery. Most (58; 91%) healed. In 40 of the patients with a stress fracture (62.5%), pubic nonunion also occurred. Those with a stress fracture were significantly older (mean 33.9 years (16 to 50) vs 30.5 years (15 to 56), p = 0.002) and had significantly more mean pre-operative deformity: mean centre-edge angle (9.8° (-9.5 to 35) vs 12.4° (-33 to 28), p = 0.04) and mean Tönnis angle (22.8° (0 to 45) vs 18.7° (-2 to 38), p < 0.001). The pubic nonunion rate was significantly higher in those with a stress fracture (62.5% vs 7%, p < 0.001), with regression analysis revealing that these patients had 11.8 times higher risk than those without nonunion.

  15. Cavitary acetabular defects treated with morselized cancellous bone graft and cementless cups

    PubMed Central

    Pereira, G. C.T.; Kubiak, E. N.; Levine, B.; Chen, F. S.

    2006-01-01

    The use of impacted morselized cancellous bone grafts in conjunction with cementless hemispherical acetabular cups for treatment of AAOS type II acetabular cavitary deficiencies was evaluated in a retrospective study of 23 primary and 24 revision total hip arthroplasties, at a mean follow-up of 7.9 and 8.1 years, respectively. All primary hips received autografts, while all revision hips received allografts. Modified Harris Hip Scores for primary and revision hip replacements increased from a pre-operative mean of 37 and 47 to a postoperative mean of 90 and 86, respectively. All 23 autografts and 23 out of 24 cancellous allografts were radiographically incorporated without evidence of resorption. There were no instances of infection, component migration, or cases requiring subsequent acetabular revision. We conclude that impacted morselized cancellous bone-graft augmentation of cementless cups is a viable surgical option for AAOS type II cavitary acetabular defects. PMID:16988799

  16. Modified Stoppa Approach versus Ilioinguinal Approach for Anterior Acetabular Fractures; A Systematic Review and Meta-Analysis

    PubMed Central

    Meena, Sanjay; Sharma, Pankaj Kumar; Mittal, Samarth; Sharma, Jyoti; Chowdhury, Buddhadev

    2017-01-01

    Introduction: Modified Stoppa approach was introduced as an alternative to ilioinguinal approach for management of anterior fractures of acetabulum in order to reduce complications of the latter. However, the efficacy of either approach over other is not well established. The aim of this meta-analysis is to compare the efficacy of modified stoppa and ilioinguinal approach in the management of acetabular fractures in terms of a) quality of reduction achieved b) complication rates c) functional outcomes d) operative time e) intra-operative blood loss. Methods: Databases of PubMed, EMBASE and Cochrane registry of controlled trials were taken into consideration for studies on modified Stoppa approach versus Ilioinguinal approach group for the treatment of anterior acetabular fractures. Dichotomous variables were presented as risk ratios (RRs) /Odds Ratio (OR) with 95% confidence intervals (CIs), and continuous data was measured as mean differences, with 95% CIs. Result: Four studies involving 375 patients were included in this meta-analysis. Out of those 375 patients, 192 were managed with ilioinguinal approach and 183 were managed with modified Stoppa approach. Anatomical reduction was significantly higher in Stoppa group (p=0.052, RR=1. 19 (1.02, 1.37), p=0. 90, I2=0%). The complication rate was significantly higher in the Ilioinguinal approach as compared with the Stoppa approach (p=0.01, RR 0.63 (0.44 to 0.91), p=0.73 (I2= 0%). The operative time was significantly shorter with modified Stoppa approach (MD = -48.79 (-80.29 to -17.30), p=0.002). No significant differences were found between the two groups in terms of their functional outcomes (p=0.63, RR 0.96 (-0.80 to 1.15), p=0. 56, I2=0%) and blood loss (MD= -212.89 (-476.27 to 50.49) p=0. 06, I2=71%). Conclusion: Anterior acetabular fractures, if operated with the modified Stoppa approach were found to have better reduction and lower complication rates with less operative time, when compared to ilioinguinal

  17. [Kocher-Langenbeck approach in the surgical management of posterior wall fractures of the acetabulum].

    PubMed

    Fernández-Palomo, L J

    2016-01-01

    Surgical treatment of acetabular fractures is indicated in displaced cases in order to restore and stabilize the hip joint and the pelvic ring integrity. Posterior structure fractures must be treated through posterior pelvic surgical approaches. The Kocher-Langenbeck is the most recommended approach for the majority of posterior acetabular fractures.

  18. Nanotechnology for treating osteoporotic vertebral fractures

    PubMed Central

    Gao, Chunxia; Wei, Donglei; Yang, Huilin; Chen, Tao; Yang, Lei

    2015-01-01

    Osteoporosis is a serious public health problem affecting hundreds of millions of aged people worldwide, with severe consequences including vertebral fractures that are associated with significant morbidity and mortality. To augment or treat osteoporotic vertebral fractures, a number of surgical approaches including minimally invasive vertebroplasty and kyphoplasty have been developed. However, these approaches face problems and difficulties with efficacy and long-term stability. Recent advances and progress in nanotechnology are opening up new opportunities to improve the surgical procedures for treating osteoporotic vertebral fractures. This article reviews the improvements enabled by new nanomaterials and focuses on new injectable biomaterials like bone cements and surgical instruments for treating vertebral fractures. This article also provides an introduction to osteoporotic vertebral fractures and current clinical treatments, along with the rationale and efficacy of utilizing nanomaterials to modify and improve biomaterials or instruments. In addition, perspectives on future trends with injectable bone cements and surgical instruments enhanced by nanotechnology are provided. PMID:26316746

  19. Nanotechnology for treating osteoporotic vertebral fractures.

    PubMed

    Gao, Chunxia; Wei, Donglei; Yang, Huilin; Chen, Tao; Yang, Lei

    2015-01-01

    Osteoporosis is a serious public health problem affecting hundreds of millions of aged people worldwide, with severe consequences including vertebral fractures that are associated with significant morbidity and mortality. To augment or treat osteoporotic vertebral fractures, a number of surgical approaches including minimally invasive vertebroplasty and kyphoplasty have been developed. However, these approaches face problems and difficulties with efficacy and long-term stability. Recent advances and progress in nanotechnology are opening up new opportunities to improve the surgical procedures for treating osteoporotic vertebral fractures. This article reviews the improvements enabled by new nanomaterials and focuses on new injectable biomaterials like bone cements and surgical instruments for treating vertebral fractures. This article also provides an introduction to osteoporotic vertebral fractures and current clinical treatments, along with the rationale and efficacy of utilizing nanomaterials to modify and improve biomaterials or instruments. In addition, perspectives on future trends with injectable bone cements and surgical instruments enhanced by nanotechnology are provided.

  20. Fractures of a single design of highly cross-linked polyethylene acetabular liners: an analysis of voluntary reports to the United States Food and Drug Administration.

    PubMed

    Ast, Michael P; John, Thomas K; Labbisiere, Anthony; Robador, Nicolas; Valle, Alejandro Gonzalez Della

    2014-06-01

    Polyethylene liner fracture is a risk associated with the use of highly cross-linked UHMWPE. We performed a review of the voluntary reports of fractured liners to the US Food and Drug Administration to determine if any risk factors could be identified. There have been 74 reports of fractured Trilogy, Longevity liners to the US Food and Drug Administration since 1999. Most cases utilized small acetabular shells (≤54 mm) combined with large diameter heads (≥36 mm). Liners less than 7 mm thick at the weight bearing or 4.8 mm thick at the rim should be used with caution. At revision surgery, malpositioned shells should be revised and the use of a thin liner should be avoided.

  1. Advances in treating exposed fractures.

    PubMed

    Nogueira Giglio, Pedro; Fogaça Cristante, Alexandre; Ricardo Pécora, José; Partezani Helito, Camilo; Lei Munhoz Lima, Ana Lucia; Dos Santos Silva, Jorge

    2015-01-01

    The management of exposed fractures has been discussed since ancient times and remains of great interest to present-day orthopedics and traumatology. These injuries are still a challenge. Infection and nonunion are feared complications. Aspects of the diagnosis, classification and initial management are discussed here. Early administration of antibiotics, surgical cleaning and meticulous debridement are essential. The systemic conditions of patients with multiple trauma and the local conditions of the limb affected need to be taken into consideration. Early skeletal stabilization is necessary. Definitive fixation should be considered when possible and provisional fixation methods should be used when necessary. Early closure should be the aim, and flaps can be used for this purpose.

  2. Late sciatic nerve axonotmesis following acetabular reconstruction plate.

    PubMed

    Moreta, J; Foruria, X; Labayru, F

    2016-01-01

    Sciatic nerve injuries associated with acetabular fractures can be post-traumatic, perioperative or postoperative. Late postoperative injury is very uncommon and can be due to heterotopic ossifications, muscular scarring, or implant migration. A case is presented of a patient with a previous transverse acetabular fracture treated with a reconstruction plate for the posterior column. After 17 years, she presented with progressive pain and motor deficit in the sciatic territory. Radiological and neurophysiological assessments were performed and the patient underwent surgical decompression of the sciatic nerve. A transection of the nerve was observed that was due to extended compression of one of the screws. At 4 years postoperatively, her pain had substantially diminished and the paresthesias in her leg had resolved. However, her motor symptoms did not improve. This case report could be relevant due to this uncommon delayed sciatic nerve injury due to prolonged hardware impingement.

  3. [Periprosthetic Acetabulum Fractures].

    PubMed

    Schreiner, A J; Stuby, F; de Zwart, P M; Ochs, B G

    2016-12-01

    In contrast to periprosthetic fractures of the femur, periprosthetic fractures of the acetabulum are rare complications - both primary fractures and fractures in revision surgery. This topic is largely under-reported in the literature; there are a few case reports and no long term results. Due to an increase in life expectancy, the level of patients' activity and the number of primary joint replacements, one has to expect a rise in periprosthetic complications in general and periprosthetic acetabular fractures in particular. This kind of fracture can be intra-, peri- or postoperative. Intraoperative fractures are especially associated with insertion of cementless press-fit acetabular components or revision surgery. Postoperative periprosthetic fractures of the acetabulum are usually related to osteolysis, for example, due to polyethylene wear. There are also traumatic fractures and fractures missed intraoperatively that lead to some kind of insufficiency fracture. Periprosthetic fractures of the acetabulum are treated conservatively if the implant is stable and the fracture is not dislocated. If surgery is needed, there are many possible different surgical techniques and challenging approaches. That is why periprosthetic fractures of the acetabulum should be treated by experts in pelvic surgery as well as revision arthroplasty and the features specific to the patient, fracture and prosthetic must always be considered.

  4. Acetabular perforation after medial migration of the helical blade through the femoral head after treatment of an unstable trochanteric fracture with proximal femoral nail antirotation (PFNA): a case report.

    PubMed

    Takigami, Iori; Ohnishi, Kazuichiro; Ito, Yoshiki; Nagano, Akihito; Sumida, Hisashi; Tanaka, Kaori; Shimizu, Katsuji

    2011-09-01

    The proximal femoral nail antirotation is a new generation of intramedullary device for the treatment of trochanteric femoral fractures, having a helical blade rather than a screw for suggested better purchase in osteoporotic bone. However, it is not free of complications. Few reports are available on postoperative perforation of the helical blade through the femoral head as a unique complication of proximal femoral nail antirotation. We report a 79-year-old woman with acetabular perforation after migration of the helical blade through the femoral head after an unstable trochanteric fracture, which was fixed with a proximal femoral nail antirotation.

  5. Acetabular revision with freeze-dried irradiated and chemically treated allograft: a minimum 5-year follow-up of 17 cases

    PubMed Central

    Caton, Jacques

    2007-01-01

    We reviewed the results of 17 consecutive revision total hip arthroplasties performed with the use of freeze-dried irradiated bone allograft in 15 patients. These allografts were used in conjunction with five Kerboull rings, two steel meshes and ten cemented isolated cups. All the patients have had a follow-up of at least 5 years. The patients were evaluated clinically and radiographically. No revisions were necessary and X-rays confirmed partial or total ingrowth of the allografts. In acetabular revision surgery, hip reconstruction can be successfully treated by freeze-dried irradiated and chemically treated allografts. Additional studies with longer term follow-up are necessary to confirm this outcome. PMID:17828537

  6. Avulsion Fracture: How Is It Treated?

    MedlinePlus

    ... weeks on crutches if you have an avulsion fracture around your hip. If the bone fragment and main bone are too far apart to fuse naturally, surgery may be necessary to reunite them. In children, avulsion fractures that involve the growth plates also might require ...

  7. Preventing and Treating Compression Fractures of the Spine

    MedlinePlus

    ... Treating Compression Fractures of the Spine 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD 20878 (800) 981- ... osteogenesis imperfecta contact : Osteogenesis Imperfecta Foundation 804 W. Diamond Avenue, Suite 210, Gaithersburg, MD 20878 Tel: 800- ...

  8. Extremely high fracture rate of a modular acetabular component with a sandwich polyethylene ceramic insertion for THA: a preliminary report.

    PubMed

    Kircher, Jörn; Bader, Rainer; Schroeder, Bettina; Mittelmeier, Wolfram

    2009-09-01

    Improvements of ceramic components and design changes have reduced failure rates over the past 30 years in total hip arthroplasty. We present a series of n = 11 cases with ceramic failure out of n = 113 implantations, from which n = 66 were ceramic-on-ceramic (n = 50 with ceramic insert with sandwich in polyethylene and n = 16 with directly fixed ceramic inlay) and n = 47 ceramic on polyethylene bearings, between 1999 and 2001 after introduction of a new implantation system to the market. The overall fracture rate of ceramic for the whole series (n = 113) was 9.7%. For the combination ceramic head with UHMW-PE (n = 47) the fracture rate was 2.1%. For the combination ceramic with ceramic (n = 66) the fracture rate was 15.2%. For the combination ceramic with ceramic sandwich in PE (n = 50) the failure rate was 18%. Only three patients experienced a trauma. Demography of patients (age, gender, body weight and BMI) was not statistically different between patients with failed ceramics and the rest of the patients making patient-specific risk factors unlikely to be an explanation for the failures. Retrospective X-ray analysis of the cup positioning did not show significant difference between failed and non-failed implants in terms of mean cup inclination and version making also operation-specific factors unlikely to be the only reason of this high failure rate. Therefore, manufacturer-specific factors such as design features may have contributed to this high failure rate. Further analysis of the whole series with biomechanical testing of the retrieved material needs to be performed.

  9. Unstable Distal Radius Fractures Treated by Volar Locking Anatomical Plates

    PubMed Central

    Jose, Anto; Deniese, Pascal Noel; Babu, Abey Thomas; Rengasamy, Kanagasabai; Najimudeen, Syed

    2017-01-01

    Introduction Fracture of the distal end of radius represents the most common fracture of the upper extremity accounting for 16-20% of all fractures. Plating is now emerging as the gold standard for management of distal radius fractures due to increased rate of complications such as malunion, subluxation/dislocation of distal radio-ulnar joint or late collapse of fracture. Procedures such as closed reduction and cast immobilization, ligamentotaxis with external fixator and percutaneous pin fixation are no longer acceptable. Aim The purpose of the study was to evaluate the functional and radiological outcome of unstable distal radius fractures treated with the volar locking plate. Materials and Methods We reviewed 53 patients from January 2011 to December 2015, treated for unstable distal radius fractures using a volar locking compression plate. Standard radiographic and clinical assessment after 12 months (range 12-16 months) were measured and final functional and radiological outcome were assessed using the Modified Mayo wrist scoring system and Sarmiento’s modification of Lindstorm criteria respectively. Results There were 42 males and 11 females with an average age of 39.12±31.78 years (18-71 years). At the end of 12 months, 36 patients had an excellent radiological outcome and 10 patients had good radiological outcome as per Sarmiento’s modification of Lindstorm criteria. Eleven patients had an excellent functional outcome and 26 patients had a good functional outcome as per modified Mayo wrist scoring system. There was one case of superficial wound infection which subsided with intravenous antibiotics. Conclusion The volar locking plate fixation helps in early mobilization of the wrist, restores anatomy, allows early return to function, prevents secondary loss of reduction and hence is an effective treatment for unstable fractures of the distal radius. PMID:28274009

  10. Fracture resistance of endodontically treated premolars with direct composite restorations

    PubMed Central

    Moezizadeh, Maryam; Mokhtari, Nastaran

    2011-01-01

    Purpose: To determine the fatigue resistance and failure mode of endodontically treated premolars using direct composite resin restorations. Materials and Methods: Eighty-four human premolars were divided into seven groups of 12, prepared as follows: Intact teeth used in Group 1 as control, the second group covers the endodontically treated teeth, restored with direct onlays using Z250 composite resin, the next two groups (i.e. 3,4) were similar to the second group, but subjected to 1 and 2 million fatigue load cycles, respectively. Groups 5, 6, 7 were similar to groups 2, 3, 4, however, in these groups Tetric Ceram was used as the restorative material. All specimens were loaded using a Universal Testing Machine until fracture occurred. One-way Anova andTukey's HSD tests were used to analyze the data of onlay groups. Results: All specimens withstood the masticating simulation. The mean fracture strength for Goups 1 to 7 was: 1276.92, 1373.47, 1269/70, 486/35, 484/12, 1130/49, 1113/79 Newton, respectively. No statistically significant differences were found between the groups in fracture strength and failure mode. Conclusions: No statistically significant differences in fracture strength were found between sound teeth and composite onlays that were subjected to 1 and 2 million fatigue load cycles. PMID:22025833

  11. Lateral decubitus for treating pertrochanteric fractures using cephalomedullary nails☆

    PubMed Central

    de Oliveira, Elton João Nunes; Hungria, José Octávio Soares; Bellan, Davi Gabriel; Borracini, Jonas Aparecido

    2015-01-01

    Objective To perform a retrospective radiographic evaluation on the fracture reduction and implant position in the femoral head among patients with pertrochanteric fractures who had been treated using a cephalomedullary nail in lateral decubitus; and to assess factors that might interfere with the quality of the fracture reduction and with the implant position in using this technique. Methods Nineteen patients with a diagnosis of pertrochanteric fractures of the femur who had been treated using cephalomedullary nails in lateral decubitus were evaluated. For outpatient radiographic evaluations, we used the anteroposterior view of the pelvis and lateral view of the side affected. We measured the cervicodiaphyseal angle, tip-apex distance (TAD), spatial position of the cephalic element in relation to the head, and the bispinal diameter. To make an anthropometric assessment, we used the body mass index. Two groups of patients were created: one in which all the criteria were normal (TAD ≤25 mm, cervicodiaphyseal angle between 130° and 135° and cephalic implant position in the femoral head in the central–central quadrant); and another group presenting alterations in some of the criteria for best prognosis. Results Female patients predominated (57.9%) and the mean age was 60 years. Seven patients presented a central–central cephalic implant position. One patient present a cervicodiaphyseal angle >135° and the maximum TAD was 32 mm; consequently, 12 patients presented some altered criteria (63.2%). None of the characteristics evaluated differed between the patients with all their criteria normal and those with some altered criteria, or showed any statistically significant association among them (p > 0.05). Conclusion The technique described here enabled good reduction and good positioning of the implant, independent of the anthropometric indices and type of fracture. PMID:26401500

  12. A technique to remove a stable all-polyethylene cemented acetabular liner in revision hip arthroplasty: A case report

    PubMed Central

    Judas, Fernando M.; Lucas, Francisco M.; Fonseca, Ruben L.

    2015-01-01

    Introduction The removal of a well-fixed acetabular component in a total hip arthroplasty can cause bone fractures, excessive bleeding, as well as extended bone loss. The reimplantation of a new acetabular component may be compromised. Presentation of case We report a technique using 2 cork-screws for removal a stable cemented acetabular component for the treatment of a recurrent dislocation of a cemented total hip arthroplasty, due to acetabular malposition. Discussion A diversity of approaches and tools has been used for extraction of the acetabular prosthesis. Using 2 cork-screws it is possible to create fissures and fractures into the cement mantle, and greater manual control is obtained facilitating the manipulation of the acetabular component in different directions. The cup-cemented bond can be disrupted, the host bone is preserved and the risks of complications are minimized. Conclusion This technique is simple, available in any environment, reproducible, non-costly, non-timing consuming and safe. PMID:25725330

  13. Cementless acetabular revision arthroplasty

    PubMed Central

    Jain, Rina; Schemitsch, Emil H.; Waddell, James P.

    2000-01-01

    Objective To evaluate the effects of clinical factors on outcome after acetabular revision with a cementless beaded cup. Design Retrospective case series. Setting Tertiary care referral centre. Patients Forty-one patients who underwent acetabular revision with a cementless cup were followed up for a mean of 3.4 years. Interventions Acetabular revision with a beaded cementless cup in all patients. A morcellized allograft was used in 10 patients. Outcome measures A modified Harris hip score (range of motion measurement omitted), the SF-36 health survey, and the Western Ontario McMaster (WOMAC) osteoarthritis index. Multivariate analysis was used to evaluate the effects of age, gender, morcellized allografting, time to revision from the previous operation, acetabular screw fixation and concurrent femoral revision on outcome. Results Gender accounted for a significant portion of the variation seen in the SF-36 physical component scores (r = 0.36, p = 0.02), with women tending to have worse results. Increasing age was associated with lower WOMAC index function scores (r = 0.36, p = 0.03), whereas concurrent femoral revision tended to have a positive effect on WOMAC index function (r = 0.39, p = 0.01). None of the potential clinical predictors had any significant effect on the SF-36 mental component scores, or WOMAC index pain and stiffness scores. Conclusions In cementless acetabular revision arthroplasty, physical function, as measured by generic and limb-specific scales, may be affected by gender, age and the presence of a concurrent femoral revision. Time to revision from the previous operation, morcellized allografting and screw fixation of the acetabulum did not affect outcomes. This information may provide some prognostic value for patients’ expectations. PMID:10948687

  14. Significance and targeting of small, central clefts in severe fractures treated with vertebroplasty.

    PubMed

    Rad, A Ehteshami; Gray, L A; Kallmes, D F

    2008-08-01

    We report a small cohort of patients with severe osteoporotic fractures treated with vertebroplasty. We note a high prevalence of small, central, intraosseous clefts in these severe fractures. Rather than filling the small amount of residual bone marrow around the periphery of these severe fractures, as suggested by previous authors, we suggest central needle placement to fill these central clefts.

  15. Use of orthogonal or parallel plating techniques to treat distal humerus fractures.

    PubMed

    Abzug, Joshua M; Dantuluri, Phani K

    2010-08-01

    Distal humerus fractures continue to be a complex fracture to treat. This article describes two surgical techniques that can be used to tackle these difficult fractures: Parallel plating and orthogonal plating. Both techniques have yielded excellent outcomes after open reduction and internal fixation; yet each has its own set of unique considerations. However, the key to successful treatment of these difficult fractures regardless of technique remains obtaining anatomic reduction with stable fixation and the implementation of early motion.

  16. Anterior tibial stress fracture treated with intramedullary nailing: a case report.

    PubMed

    Plasschaert, V F; Johansson, C G; Micheli, L J

    1995-01-01

    This article describes the use of intramedullary rodding as a treatment for an anterior tibial stress fracture in a patient with high functional demands: a professional ballet dancer. In our patient, a year of conservative treatment and later tibial drilling was unsuccessful. After sustaining a complete fracture at the site of the stress fracture, he was treated with intramedullary rodding and was able to dance 21 weeks after surgery. The fracture went on to complete healing. The role of prophylactic intramedullary nailing in this difficult fracture is discussed.

  17. Using a tightRope® to treat a complex fracture of the trapezium

    PubMed Central

    Mohan, A; Sarkhel, T

    2014-01-01

    We present the case of a 23-year-old man with a combined scaphoid fracture and comminuted trapezium fracture, treated surgically with percutaneous fixation of the scaphoid fracture and concomitant Arthrex Mini TightRope® stabilisation of base of thumb metacarpal to base of index finger metacarpal. The patient made a good functional recovery, returning to usual activities within six weeks. We suggest that this technique could be used to treat complex trapezium fractures that cannot be reconstructed with surgery. PMID:25245724

  18. Surgical management of fractures of the acetabulum: the Sheffield experience 1976-1994.

    PubMed

    Hull, J B; Raza, S A; Stockley, I; Elson, R A

    1997-01-01

    Of 56 acetabular fractures treated in Sheffield between 1976 and 1994, 43 fractures in 40 patients underwent open reduction and internal fixation. This paper reviews the surgically managed fractures with emphasis on the quality of operative reduction and outcome, in particular the development of degenerative osteoarthritis leading to total hip replacement. A good clinical result following operative management was seen to correlate closely with a near perfect reduction; in contrast, all cases with a poor reduction underwent joint replacement in the follow-up period. The relatively few cases managed at a major referral centre in this series suggest that either the incidence of acetabular fracture is low in the area or that only a proportion of cases are referred from the surrounding district general hospitals.

  19. Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion

    PubMed Central

    Xu, Yongqiang; Lin, Chuangxin; Zhang, Lifeng; Lin, Miaoxiong; Lai, Jianqiang; Cao, Shenglu; Peng, Geng; Feng, Kai; Yan, Ge; Cai, Daozhang; Wang, Gang

    2016-01-01

    Background The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. Material/Methods Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and computed tomography (CT) imaging were used to collect the measured parameter data of the module. Results The measured parameter data were as follows: OP, 0.96±0.32 cm in females and 0.92±0.16 cm in males (P>0.05); PI, 0.98±0.28 cm in females, and 0.75±0.23 cm in males (P>0.05); ∠θ, 59.68°±6.28° in females and 56.75°±3.22° in males (P>0.05); and ∠ϕ, 41.27°±2.76° in females and 34.31°±2.78° in males (P<0.05). The corresponding CT image data were as follows: PI, 1.08±0.22 cm in females and 0.85±0.27 cm in males (P>0.05); OP, 1.06±0.29 cm in females and 1.12±0.24 cm in males (P>0.05); ∠θ, 55.33°±4.00° in females and 55. 50°±3.43° in males (P>0.05); and ∠ϕ was 39.21°±2.45°in females and 35.58°±2.31°in males (P<0.05). No significant difference with respect to sex and side existed between specimens and healthy adults (P>0.05). Conclusions The measured parameter data obtained in healthy adults and cadaveric specimens provided an anatomic basis for the designation of the guide module, and thus confirmed the accuracy and safety of screw placement in fractured columns of the acetabulum. PMID:27584820

  20. Secondary displacement of distal radius fractures treated by bridging external fixation.

    PubMed

    Farah, N; Nassar, L; Farah, Z; Schuind, F

    2014-05-01

    Loss of reduction remains an important problem after treatment of distal radius fractures, whatever the type of bone fixation. We assessed retrospectively the rate of secondary displacement after external fixation of distal radius fractures in order to identify possible risk factors for instability. We reviewed the pre-operative and serial post-operative radiographs of a retrospective series of 35 distal radius fractures treated by bridging external fixation. When classified according to the Société Française d'Orthopédie et Traumatologie (SOFCOT) criteria, the rate of secondary displacement was 48.5%. At final follow up, the reduction was anatomical in 12% and acceptable in 83%. There was malunion in 5%. The loss of reduction concerned primarily the distal radius palmar tilt and was moderate. No correlation was found with age, gender, type of fracture, degree of initial displacement, associated ulnar fracture, or seniority of the treating surgeon.

  1. Incipient malunion of an isolated humeral trochlea fracture treated with an elbow hemiarthroplasty: case report.

    PubMed

    Lechasseur, Benoit; Laflamme, Mélissa; Leclerc, Alexandre; Bédard, Anne-Marie

    2015-02-01

    We report the case of a 49-year-old woman with severe elbow ankylosis 10 weeks after a trochlea fracture treated with open reduction and internal fixation. Imaging confirmed failure of open reduction and internal fixation with a displaced and severely damaged trochlea. We treated the nascent malunited trochlea and associated elbow ankylosis with a distal humeral hemiarthroplasty and circumferential elbow arthrolysis. The patient regained functional range of motion of the elbow and had minimal pain. Distal humeral hemiarthroplasty, which has been indicated for acute fractures involving the capitellum or the entire distal humerus, may also be indicated for certain isolated complex fractures of the trochlea.

  2. Porous Tantalum Buttress Augments for Severe Acetabular Posterior Column Deficiency.

    PubMed

    Meneghini, R Michael; Hull, Jason R; Russo, Glenn S; Lieberman, Jay R; Jiranek, William A

    2015-11-01

    In revision total hip arthroplasty (THA), consensus is lacking regarding the optimal method for reconstruction of the most severe acetabular defects. Porous tantalum (TM) buttress augments were designed for the most severe postero-superior defects. The purpose of this study was to report the results of a consecutive series of acetabular reconstructions utilizing TM buttress augments. Eight complex acetabular reconstructions utilizing a TM buttress augment were performed at two centers. All were Paprosky 3A or Paprosky 3B bone loss classification, with severe superior and posterior column deficiency where wedge augments were insufficient for mechanical support. The acetabular cup sizes ranged from 64-78, and a buttress shim was used in 7 of 8 cases. Clinical and radiographic follow-up averaged 16.5 months (range, 10-28) and no cases were lost to follow-up. There were no cases of clinical or radiographic loosening, and no case had required reoperation or revision. All patients except one were ambulating with either no assist device or a single cane at final follow-up. There was one complication of an iliac wing fracture noted incidentally on postoperative x-rays in the lone patient in whom a buttress shim was not used. At short-term follow-up, TM acetabular buttress augments appear to effectively substitute for the use of structural allografts or cages, which would otherwise be used in this challenging setting. The potential for biologic fixation is promising for the durability of these reconstructions; however, longer-term follow-up is required for full evaluation.

  3. Numerical Fracture Analysis of Cryogenically Treated Alloy Steel Weldments

    NASA Astrophysics Data System (ADS)

    Rasool Mohideen, S.; Thamizhmanii, S.; Fatah, M. M. Muhammed Abdul; Saidin, W. Najmuddin W.

    2016-02-01

    Cryogenic treatment is being used commercially in the industries in the last two decades for improving the life of many engineering component such as bearings and cutting tools. Though their influence in improving the wear resistance of tool materials is well established, the effect of treatment on weldments is not much investigated. In the present work, a two dimensional finite element analysis was carried out on the compact tension specimen model for simulating the treatment process and to study the fracture behaviour. The weldments were modelled by thermo- mechanical coupled field analysis for simulating he temperature distribution in the model during weld pool cooling and introducing thermal stresses due to uneven contraction and cooling. The model was subjected to cryogenic treatment by adopting radiation effect. The fracture analysis was carried out using Rice's J- Integral approach. The analysis produced a similar outcome of experimental results i.e. Increase in the fracture toughness of the specimen after cryogenic treatment in the heat affected zone of weldment.

  4. Displaced intra-articular calcaneus fractures treated with the Galveston plate.

    PubMed

    Laughlin, R T; Carson, J G; Calhoun, J H

    1996-02-01

    From January 1992 to August 1993, 59 calcaneal fractures in 48 patients were treated. Thirty-three fractures in 31 patients were displaced intra-articular fractures and were treated with open reduction and internal fixation through an extensile lateral approach with the Galveston plate (Smith and Nephew, Richards, Memphis, TN). Complete radiographs and CT scans were available for 32 of the fractures. The CT scan classification of Sanders was used. The distribution of the fractures was: IIA, N = 17; IIB, N = 2; IIC, N = 2; IIIAB, N = 7; IIIAC, N = 2; IV, N = 2. Sixteen (50%) had calcaneocuboid joint involvement. Preoperative and postoperative radiographic measurements of Bohler's angle, Gissane's angle, talocalcaneal angle, and Achilles tendon fulcrum distance were made. Clinical follow-up on 23 fractures in 22 patients at an average of 21 months is presented. Seventy percent of the patients have no pain or only occasional pain not requiring medication. Using the Maryland Foot Score for assessment, 78% of the patients had a good or excellent result. The Galveston plate was useful for maintaining reduction of intra-articular calcaneus fractures treated operatively and provided results comparable to other reported series.

  5. Ligamentous Radiocarpal Fracture-Dislocation Treated with Wrist-Spanning Plate and Volar Ligament Repair

    PubMed Central

    Potter, Michael Q.; Haller, Justin M.; Tyser, Andrew R.

    2014-01-01

    Background Radiocarpal fracture-dislocations are challenging injuries that are often associated with postoperative pain, stiffness, instability, or early arthrosis. Case Description We report a 1-year follow-up of a ligamentous radiocarpal dislocation (Dumontier group I) treated with a dorsal wrist-spanning plate and volar capsular repair with good results. Literature Review Historically, Dumontier group I injuries treated with a variety of techniques (closed reduction and casting, percutaneous pinning, and open fixation) have been associated with stiffness and loss of reduction. Clinical Relevance Distraction plating is a safe and effective technique for treating select distal radius fractures, and we suggest it has the potential to produce good outcomes when used to treat radiocarpal fracture-dislocations. PMID:25364640

  6. Acoustic Emission Methodology to Evaluate the Fracture Toughness in Heat Treated AISI D2 Tool Steel

    NASA Astrophysics Data System (ADS)

    Mostafavi, Sajad; Fotouhi, Mohamad; Motasemi, Abed; Ahmadi, Mehdi; Sindi, Cevat Teymuri

    2012-10-01

    In this article, fracture toughness behavior of tool steel was investigated using Acoustic Emission (AE) monitoring. Fracture toughness ( K IC) values of a specific tool steel was determined by applying various approaches based on conventional AE parameters, such as Acoustic Emission Cumulative Count (AECC), Acoustic Emission Energy Rate (AEER), and the combination of mechanical characteristics and AE information called sentry function. The critical fracture toughness values during crack propagation were achieved by means of relationship between the integral of the sentry function and cumulative fracture toughness (KICUM). Specimens were selected from AISI D2 cold-work tool steel and were heat treated at four different tempering conditions (300, 450, 525, and 575 °C). The results achieved through AE approaches were then compared with a methodology proposed by compact specimen testing according to ASTM standard E399. It was concluded that AE information was an efficient method to investigate fracture characteristics.

  7. Retrospective review of 234 scaphoid fractures and nonunions treated with arthroscopy for union and complications.

    PubMed

    Slade, J F; Gillon, T

    2008-01-01

    The purpose of this paper is to retrospectively review 234 consecutive cases of scaphoid fractures and nonunions treated using arthroscopy with the dorsal percutaneous implantation of a headless compression screw for healing and complications. Solid union of fracture is determined by CT scan. We identified 126 acute injuries, including 65 proximal pole fractures; 67 grossly displaced fractures; 12 trans-scaphoid perilunate dislocations including four trans-scaphoid trans-capitate fractures; and ten combined scaphoid and distal radius fractures. 108 scaphoid nonunions were identified. 98 were correctly aligned and ten had a humpback deformity which was correctable using arthroscopic assisted reduction techniques at the time of surgery. 82 presented with a fracture gap 2mm or greater requiring percutaneous bone grafting. 12 cases of avascular necrosis (AVN) were identified by MRI. 20 nonunions had surgery performed at other institutions. The mean time to surgery for the nonunions was 20 months. 99% union rate of acute scaphoid fractures was obtained by 12 weeks, as determined by CT scan. Two complications were identified (3%). One case of delayed healing was identified. this delayed union was treated with percutaneous bone grafting and continued on to heal uneventfully. The other complication was a case of volar trans-scaphoid peri-lunate dislocation. While the fracture healed, the patient developed a traumatic dislocation requiring a capitate-lunate arthrodesis. Treatment of scaphoid nonunions resulted in ten cases of delayed healing, which were treated with repeat percutaneous bone grafting. This represented a 9% complication rate. of the ten cases of delayed unions that were re-bone grafted, four failed to heal by nine months. This resulted in a 96% union rate of our nonunion group by nine months. when acute fracture healing was compared to nonunions the average healing of acute fractures as determined by CT scanning measuring trabecular bridging was 12 weeks

  8. Atypical Femur Fractures in Patients Treated with Bisphosphonates: Identification, Management, and Prevention

    PubMed Central

    Bubbear, Judith Sarah

    2016-01-01

    Osteoporosis is a common condition with significant health care costs. First-line therapy is with bisphosphonates, which have proven anti-fracture efficacy. Around 10 years after the introduction of bisphosphonates reports began to be published of atypical femoral fractures (AFFs) that may be associated with this therapy. These fractures are associated with significant morbidity although lower mortality than the more common osteoporotic neck-of-femur fractures. A case definition has been described to allow identification of this class of fracture. Further work has established a high relative risk of AFFs in patients treated with bisphosphonates, but a low absolute risk in comparison to that of osteoporotic fractures. Proposed pathological mechanisms include low bone turnover states leading to stress/insufficiency fractures. Clinicians should be aware of the risk of AFFs and in particular the high rate of prodromal thigh/groin pain that warrants investigation in a patient receiving a bisphosphonate. If an incomplete fracture is diagnosed then bisphosphonate therapy needs to be stopped and prophylactic surgery may be considered. Due to these rare side effects patients on bisphosphonates require regular review, and this is particularly advised after 5 years of oral or 3 years of intravenous therapy. PMID:27824547

  9. Long Term Results of Liner Polyethylene Cementation Technique in Revision for Peri-acetabular Osteolysis.

    PubMed

    Rivkin, Gurion; Kandel, Leonid; Qutteineh, Bilal; Liebergall, Meir; Mattan, Yoav

    2015-06-01

    Patients with peri-acetabular osteolysis around a well fixed cementless acetabular component may be treated with liner exchange. When the locking mechanism is unreliable or unavailable, cementing the liner into the fixed acetabular component is a feasible option. The purpose of this study was to evaluate the clinical and radiographic long term results of this technique. Forty hip revisions with liner cementation in 37 patients were performed. The minimum follow up was 10 years. Modified Harris Hip Score and recent x rays were reviewed. Four hips were re-revised. Two patients were diagnosed with exacerbation of osteolysis but refused revision. Dislocation rate was relatively high (16%). Liner cementation technique in revision hip surgery is useful in patients with a well fixed metal backed acetabular component.

  10. A new predictive indicator by arthrography for future acetabular growth following conservative treatment of developmental dysplasia of the hip.

    PubMed

    Satsuma, Shinichi; Kobayashi, Daisuke; Kinugasa, Maki; Takeoka, Yoshiki; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-05-01

    The aim of this study was to find a new predictive indicator for acetabular growth of developmental dysplasia of the hip. Seventy-three hips that were diagnosed with developmental dysplasia of the hip and treated by conservative reduction were included in our study. In 30 hips with center-edge angle ≤ 10° at age 4, the center-edge of the acetabular limbus angle (CEALA) in the arthrogram was measured. On the basis of the results, CEALA was significantly smaller in the secondary acetabular dysplasia group than in the normal group at maturity. In conclusion, CEALA is a more reliable and accurate predictive indicator for acetabular development than center-edge angle or acetabular index.

  11. UNSTABLE FEMORAL FRACTURES TREATED WITH TITANIUM ELASTIC INTRAMEDULLARY NAILS, IN CHILDREN

    PubMed Central

    Soni, Jamil Faissal; Schelle, Gisele; Valenza, Weverley; Pavelec, Anna Carolina; Souza, Camila Deneka Arantes

    2015-01-01

    Objective: To evaluate the indications, epidemiology, associated lesions, complications and prognosis among children with unstable femoral diaphysis fractures who were treated with titanium elastic intramedullary nails. Method: This was a retrospective analysis on 24 patients aged 5-12 years with unstable femoral diaphysis fractures who underwent surgical treatment with elastic titanium intramedullary nails at the Cajuru University Hospital, Curitiba-PR, between April 2002 and March 2008, with a minimum follow-up of 36 months. The epidemiological data, angular deviations, leg shortening and bone consolidation were evaluated. Results: The medical files of 113 cases operated between April 2002 and March 2008 were reassessed. From these, 24 cases of unstable femoral diaphysis fractures treated with elastic titanium intramedullary nails with retrograde insertion were included in the study. There were two bilateral fractures and two exposed fractures. Seven patients were female and 17 were male, and the mean age was 8.3 years. The following were presented at the end of the study: shortening, varus or valgus displacement, final retrocurvatum or antecurvatum of zero, and absence of delayed consolidation or pseudarthrosis. Conclusions: The elastic titanium intramedullary nails were easily placed and removed. We believe that using elastic titanium intramedullary nails is a good option for fixation of unstable femoral fractures in children. PMID:27047868

  12. Functional Outcome of Conservatively Treated Bilateral Neck of Femur Fracture in an Elderly: A Case Report

    PubMed Central

    2016-01-01

    Bilateral Neck of Femur (NOF) fractures is relatively rare. Surgery, either osteosynthesis or hemireplacement arthroplasty, is the mainstay of treatment. Significant complications are known to occur in such cases. In this case report, we present the functional outcome of a conservatively treated bilateral NOF fracture at one year, in a 93-year-old man. Our patient, a 93-year-old gentleman, sustained right side NOF fracture in May 2014 and left side NOF fracture in May 2015, both after trivial fall. He did not give consent for surgery considering high operative risk. Now, at one year follow-up he has no true or apparent limb length discrepancy. He is ambulant with walker, self reliant for toilet care and other personal needs. Harris hip score is 75.80 and 69.65 after 1 year from right and left NOF fracture respectively. In view of high mortality after surgery for NOF fracture in high risk patients or unavailability of resources, conservative treatment for bilateral NOF fracture can achieve satisfactory functional outcome in selected patients. PMID:28208960

  13. Nonoperatively treated forearm shaft fractures in children show good long-term recovery

    PubMed Central

    Sinikumpu, Juha-Jaakko; Victorzon, Sarita; Antila, Eeva; Pokka, Tytti; Serlo, Willy

    2014-01-01

    Background and purpose — The incidence of forearm shaft fractures in children has increased and operative treatment has increased compared with nonoperative treatment in recent years. We analyzed the long-term results of nonoperative treatment. Patients and methods — We performed a population-based age- and sex-matched case-control study in Vaasa Central Hospital, concerning fractures treated in the period 1995–1999. There were 47 nonoperatively treated both-bone forearm shaft fractures, and the patients all participated in the study. 1 healthy control per case was randomly selected and evaluated for comparison. We analyzed clinical and radiographic outcomes of all fractures at a mean of 11 (9–14) years after the trauma. Results — The main outcome, pronosupination of the forearm, was not decreased in the long term. Grip strength was also equally as good as in the controls. Wrist mobility was similar in flexion (85°) and extension (83°) compared to the contralateral side. The patients were satisfied with the outcome, and pain-free. Radiographally, 4 cases had radio-carpal joint degeneration and 4 had a local bone deformity. Interpretation — The long-term outcome of nonoperatively treated both-bone forearm shaft fractures in children was excellent. PMID:25238437

  14. Acetabular augmentation for the treatment of unstable total hip arthroplasties.

    PubMed Central

    Nicholl, J. E.; Koka, S. R.; Bintcliffe, I. W.; Addison, A. K.

    1999-01-01

    Twenty-eight unstable total hip arthroplasties were treated with an acetabular augmentation wedge. Of the hips, 23 have had no further dislocations at a mean follow-up of 26 months. Five patients continued to dislocate and have needed further surgery. To our knowledge this is the largest reported series of acetabular augmentation with as good results as those of the most successful reported series of this technique, and a success rate comparable to other methods of treating recurrent dislocation. Careful patient selection, and using a thin augmentation wedge to avoid impingement, are important to the success of a technique which is a useful option in the management of recurrent dislocation. Images Figure 1 PMID:10364973

  15. Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite

    PubMed Central

    Isufi, Almira; Plotino, Gianluca; Grande, Nicola Maria; Ioppolo, Pietro; Testarelli, Luca; Bedini, Rossella; Al-Sudani, Dina; Gambarini, Gianluca

    2016-01-01

    Summary Aim To determine and compare the fracture resistance of endodontically treated teeth restored with a bulk fill flowable material (SDR) and a traditional resin composite. Methods Thirty maxillary and 30 mandibular first molars were selected based on similar dimensions. After cleaning, shaping and filling of the root canals and adhesive procedures, specimens were assigned to 3 subgroups for each tooth type (n=10): Group A: control group, including intact teeth; Group B: access cavities were restored with a traditional resin composite (EsthetX; Dentsply-Italy, Rome, Italy); Group C: access cavities were restored with a bulk fill flowable composite (SDR; Dentsply-Italy), except 1.5 mm layer of the occlusal surface that was restored with the same resin composite as Group B. The specimens were subjected to compressive force in a material static-testing machine until fracture occurred, the maximum fracture load of the specimens was measured (N) and the type of fracture was recorded as favorable or unfavorable. Data were statistically analyzed with one-way analysis of variance (ANOVA) and Bonferroni tests (P<0.05). Results No statistically significant differences were found among groups (P<0.05). Fracture resistance of endodontically treated teeth restored with a traditional resin composite and with a bulk fill flowable composite (SDR) was similar in both maxillary and mandibular molars and showed no significant decrease in fracture resistance compared to intact specimens. Conclusions No significant difference was observed in the mechanical fracture resistance of endodontically treated molars restored with traditional resin composite restorations compared to bulk fill flowable composite restorations. PMID:27486505

  16. EPIDEMIOLOGICAL PROFILE OF PATIENTS WITH PROXIMAL HUMERUS FRACTURE TREATED AT HOSPITAL SÃO PAULO, BRAZIL

    PubMed Central

    de Oliveira, Ana Paula Cortes; Mestieri, Mariana Christovam; Pontin, José Carlos Baldocchi

    2015-01-01

    ABSTRACT Objective: To analyze the epidemiological aspects of proximal humerus fractures and describe the profile of patients with proximal humerus fractures hospitalized and treated at Hospital São Paulo, between 2008 and 2013. Methods: Hospital records were retrospectively analyzed for surgically treated patients diagnosed with proximal humerus fracture. Age, gender, injury mechanism, length of hospital stay, performed treatment and associated diseases were considered. Results: From all patients studied, 52 were female at their sixth decade of life. As for the injury mechanism, fall from height was the main cause for women (88.46%) and for man it was motorcycle accidents (31.42%). Fixation with locked plate was the most frequently used treatment. Conclusion: Most patients were female in their fifth decade of life, injured mainly by fall from height. Fixation with locked plate was the most frequently used treatment and the patients were admitted for 7 days, on average. Level of Evidence II, Retrospective Study. PMID:26981037

  17. A comparative assessment of fracture resistance of endodontically treated and re-treated teeth: An in vitro study

    PubMed Central

    Ganesh, Arathi; Venkateshbabu, Nagendrababu; John, Aby; Deenadhayalan, Gogulnath; Kandaswamy, Deivanayagam

    2014-01-01

    Aim: To compare and assess the fracture resistance of endodontically treated teeth with those that have been subjected to endodontic retreatment. Materials and Methods: 30 extracted mandibular premolars were decoronated at cementoenamel junction and randomly divided into 2 groups. In Group I endodontic treatment was performed with ProTaper rotary system till size F2 and obturated. In Group II, cleaning and shaping was done and teeth were subjected to Spiral CT to assess the remaining dentin thickness and obturated. Later retreatment was done using Protaper Universal Retreatment system and final shaping was performed till size F3. Remaining dentin thickness was again assessed using Spiral CT and then obturated. All the specimens were subjected to fracture resistance using universal testing machine. The results were statistically analyzed using Independent Samples t-test for analysis of remaining dentin thickness using SCT within Group II and Paired Samples t-test was used for assessment of fracture resistance between Group I and II (P < 0.05). Results: In Group II, the intra group comparison of the remaining dentin thickness in the coronal third reveals statistical significance, with a significant difference noted in the apical third. Results of the fracture resistance reveal a statistically significant difference (P < 0.05) between Groups I and II with the mean fracture resistance of Group I being higher than Group II. Conclusion: Endodontically retreated teeth have shown significantly decreased resistance to fracture and this has a positive correlation to the increased loss of root dentin during the retreatment procedures PMID:24554864

  18. Effect of Different Instrumentation Techniques on Vertical Root Fracture Resistance of Endodontically Treated Teeth

    PubMed Central

    Tavanafar, Saeid; Karimpour, Azadeh; Karimpour, Hamideh; Mohammed Saleh, Abdulrahman; Hamed Saeed, Musab

    2015-01-01

    Statement of the Problem Vertical root fractures are catastrophic events that often result in tooth extraction. Many contributing factor are associated with increasing incidence of vertical root fracture. Root canal preparation is one of the predisposing factors which can increase the root susceptibility to vertical fracture. Purpose The aim of this study was to compare the effects of three different instrumentation techniques on vertical root fracture resistance of endodontically treated teeth. Materials and Methods In this study, 120 freshly extracted mandibular premolar teeth of similar dimensions were decoronated and randomly divided into control (n=30), nickel-titanium hand K-file (HF, n=30), BioRaCe rotary file (BR, n=30), and WaveOne reciprocating single-file (WO, n=30) groups. After cleaning and shaping the root canals, AH26 was used as canal sealer, and obturation was completed using the continuous wave technique. The root canals were embedded vertically in standardised autopolymerising acrylic resin blocks, and subjected to a vertical load to cause vertical root fracture. The forces required to induce fractures were measured using a universal testing machine. ANOVA and Tukey’s post-hoc test were used to analyse the data. Results All experimental groups showed statistically significant reductions in fracture resistance as compared with the control group. There was a statistically significant difference between the HF and BR groups. The WO group did not differ significantly from the HF group or the BR group. Conclusion All three instrumentation techniques caused weakening of the structure of the roots, and rendered them susceptible to fracture under lesser load than unprepared roots. The fracture resistance of roots prepared with the single-file reciprocating technique was similar to that of those prepared with NiTi hand and rotary instrumentation techniques. PMID:26106635

  19. Outcome of unstable fractures of metacarpal and phalangeal bones treated by bone tie

    PubMed Central

    Kamath, Jagannath B; Jayasheelan, Nikil; Savur, Amaranth; Mathews, Rejith

    2016-01-01

    Background: Unstable fractures of the metacarpal and phalangeal bones of the hand need surgical stabilization which should be rigid enough for early active mobilization. Conventional methods of open reduction and stabilization in the form of composite fixation or screws with or without plates have served the purpose but can be definitely improvised addressing both biological and mechanical principles of fixation. Materials and Methods: 34 patients (29 males and 5 females) with an average age of 32 years (range 10–64 years) with unstable fractures of the metacarpal and phalangeal bones of hand who were treated with the modified bone tie between June 2009 and June 2013 were included in this study. 42 fractures, involving the 31 metacarpals and 11 phalanges were included. We have not used this technique in fractures involving the terminal phalanges. Thirty nine of the fractures were treated with K-wires along with the modified bone tie, whereas the other two cases were treated with modified bone tie alone and in one case the bone tie has been used along with the external fixator. The nature of injuries were Road Traffic Accident (n = 24), domestic/industrial injuries (n = 8) and blast (n = 2) injuries. Etiology was crush (n = 24), blunt (n = 7) and incised (n = 3) injuries, respectively. Twenty seven patients were involved with single fractures (either metacarpal or the phalanges), 6 patients had two fractures (both metacarpals or phalanges or one each of metacarpal and phalanx), and 1 patient had three fractures in this study. Dominant hand was involved in 14 patients (40%). Results: We achieved excellent to good results in 83% of 42 fractures within an average period of 10 weeks. Postoperative grip strength of 85% was achieved with in an average period of 12 weeks. Twenty six (20 metacarpals and 6 phalanges) of the 42 fractures regained >85% of the total active movements (TAMs) compared to the contralateral side were considered excellent results. All patients were

  20. The Harris-Galante cementless acetabular component: results in 190 cases with at least 3 years follow-up.

    PubMed

    Claus, B; Van Innis, B; De Witte, E; Van Overschelde, J; Magotteaux, B; Fatemi, F; Vandepaer, F

    1993-01-01

    The results of 190 primary total hip arthroplasties with a Harris-Galante cementless acetabular cup were reviewed. All patients had a minimum follow-up of 3 years (range, 3 to 5.5 years, mean 46 months). Clinical and radiographical analysis was performed. Inguinal pain was recorded in five cases. We noted a fracture of a screw in four cases without further implications. There was no evidence of acetabular loosening. There was no migration of the acetabular cup. No acetabular component showed measurable wear of the polyethylene liner. Non-progressive radiolucent lines were recorded in 14% of the patients: among these patients, radiolucent lines were noted in zone 1 in 46%, in zone 2 in 4% and in zone 3 in 86%. Two socket revisions became necessary. One patient suffered a deep-seated infection. Another revision was necessary because of recurrent dislocation.

  1. Fracture resistance of endodontically treated teeth with different direct corono-radicular restoration methods

    PubMed Central

    Moosavi, Horieh; Manari, Fatemeh

    2017-01-01

    Background Endodontically treated teeth are widely considered to be more susceptible to fracture than vital teeth. Obturation procedures and post placement have been a main cause of vertical root fracture. Material and Methods Forty-eight human premolars with standardized weakened roots were endodontically treated and allocated to four experimental groups (n=12). After root canal treatment, in group 1, fiber posts #1 were cemented in root canals using Estelite Core Quick, and the crowns were restored with resin composite. For group 2 and 3, the roots and crowns were restored using a light-cured and self-cured adhesive and resin composites respectively. In group 4, it was used the Panavia F 2.0 resin cement and resin composite for corono-radicular reconstruction. In group 5, the teeth remained untouched. After 24 hours storage and 1000 thermocycles, samples were loaded at a cross head speed of 1 mm per minute. Results A significant difference was observed in fracture resistance among groups 4 and 5 compared to other groups. Conclusions Root reconstruction with fiber post and Panavia resin cement, and crown building using light-cured resin composite resulted in increased fracture resistance equal to that of intact teeth. Key words:Fracture resistance, fiber post, resin cement, resin composite. PMID:28298991

  2. EPIDEMIOLOGY OF ACETABULUM FRACTURES TREATED AT THE INSTITUTO NACIONAL DE TRAUMATOLOGIA E ORTOPEDIA (INTO)

    PubMed Central

    Dias, Marcus Vinícius Fernandes; Goldsztajn, Flavio; Guimarães, João Matheus; Grizendi, José Afraneo; Correia, Marcos; Rocha, Tito Henrique

    2015-01-01

    Objectives: The purpose of this study was to review the epidemiological aspects of displacement fractures of the acetabulum that had been treated surgically at the National Institute of Traumatology and Orthopedics (INTO). Methods: We retrospectively analyzed 126 acetabulum fractures that had been treated surgically at INTO between March 2006 and November 2008. The following factors were taken into account: age, sex, trauma mechanism, injury classification, time elapsed between trauma and surgery, affected side and associated bone injuries. Results: 76.8% were male; the mean age was 39.6 years. The trauma mechanism was traffic accidents in 59%; the time that elapsed between injury and surgery was on average 16.4 days; 55% of the cases were on the right side; 30% of the patients presented associated fractures. Conclusion: Most of the patients were male, in an economically active age group, and were victims of traffic accidents. Edge and/or posterior column fractures were the most frequent types. Associated injuries were common and most of the fractures operated in our service came to us late. PMID:27022597

  3. Nonoperatively treated type A spinal fractures: mid-term versus long-term functional outcome.

    PubMed

    Post, R B; van der Sluis, C K; Leferink, V J M; Dijkstra, P U; ten Duis, H J

    2009-08-01

    This study focuses on the mid-term (four years) and long-term (ten years) functional outcome of patients treated nonoperatively for a type A spinal fracture without primary neurological deficit. Functional outcome was measured using the visual analogue scale spine score (VAS) and the Roland-Morris disability questionnaire (RMDQ). The 50 patients included were on average 41.2 years old at the time of injury. Four years post injury, a mean VAS score of 74.5 and a mean RMDQ score of 4.9 were found. Ten years after the accident, the mean VAS and RMDQ scores were 72.6 and 4.7, respectively (NS). No significant relationships were found between the difference scores of the VAS and RMDQ compared with age, gender, fracture sub-classification, and time between measurements. Three (6%) patients had a poor long-term outcome. None of the patients required surgery for late onset pain or progressive neurological deficit. Functional outcome after a nonoperatively treated type A spinal fracture is good, both four and ten years post injury. For the group as a whole, four years after the fracture a steady state exists in functional outcome, which does not change for ten years at least after the fracture.

  4. The functional results of tibial shaft fractures treated with intramedullary nail compressed by proximal tube.

    PubMed

    Karaarslan, Ahmet Adnan; Acar, Nihat; Aycan, Hakan; Sesli, Erhan

    2016-04-01

    Nailing of tibial shaft fractures is considered the gold standard surgical method by many surgeons. The aim of this retrospective study was to investigate and compare the clinical outcome of tibial shaft fractures treated with intramedullary nails compressed by proximal tube and conventional intramedullary interlocking nails. Fifty-seven patients with tibial shaft fractures, treated with intramedullary nails compressed by proximal tube (n = 32) and the conventional interlocking nails (n = 25), were reviewed. All fractures except for one were united without any additional surgical intervention in the proximal compression tube nail group, whereas in the conventional interlocking nail group, six patients needed dynamization surgery (p = 0.005) and three cases of nonunion were recorded. In the proximal compression tube nail group, faster union occurred in 20 ± 2 (16-24) weeks (mean ± SD; range) without failure of locking screws and proximal nail migration, whereas in the conventional interlocking nail group, union occurred in 22 ± 2.5 (17-27) weeks (p = 0.001) with two failures of locking screws and two proximal nail migration. The proximal compression tube nail system is safer than the conventional nailing methods for the treatment for transverse and oblique tibial shaft fractures with a less rate of nonunion, proximal locking screw failure and proximal nail migration.

  5. The effect of temporary restorative materials on fracture resistance of endodontically treated teeth.

    PubMed

    Milani, Amin Salem; Froughreyhani, Mohammad; Mohammadi, Hosein; Tabegh, Fatemeh Ghasemi; Pournaghiazar, Fatemeh

    2016-01-01

    This study was designed to investigate the fracture strength of endodontically treated teeth temporarily restored with some commonly used interim materials. Of 90 extracted maxillary premolars used in this study, 15 were left intact as the positive control. Endodontic treatment was performed on the remaining 75 teeth. The endodontically treated teeth were then randomly assigned to 5 groups (n = 15). One group was not restored and served as the negative control. In the remaining 4 experimental groups, the teeth were restored with a temporary cement: Zonalin, IRM, Coltosol, or Fuji II LC resin-modified glass ionomer (RMGI). The fracture strengths of all teeth were measured with a universal testing machine. The fracture strength of teeth restored with RMGI was significantly greater than that of other groups (P < 0.001), including intact teeth (P = 0.025). The fracture strength of teeth restored with other temporary materials was significantly lower than that of intact teeth (P < 0.05) but not significantly different from that of the negative control. From a structural resistance standpoint, RMGI may be the best choice for short-term temporary restoration of endodontically treated teeth. Other types of temporary restorative material had no reinforcing effect on tooth structure.

  6. Postpartum osteoporosis and vertebral fractures in two patients treated with enoxaparin during pregnancy.

    PubMed

    Ozdemir, D; Tam, A A; Dirikoc, A; Ersoy, R; Cakir, B

    2015-01-01

    Postpartum osteoporosis (PPO) is a rare disease associated with pregnancy and lactation period. Here, we report severe PPO and multiple vertebral compression fractures in two patients treated with enoxaparin--low-molecular-weight heparin (LMWH)--throughout their pregnancy. A 34-year-old woman who has delivered her second baby 3 months ago presented with severe low-back pain. She was treated with enoxaparin 40 mg/day for 8 months during her pregnancy. Dual-energy X-ray absorptiometry (DEXA) showed low T- and Z-scores in lumbar (L) vertebras. In magnetic resonance imaging (MRI), severe height losses in thoracic (T) 12, L1, and L2 vertebras were detected. She was diagnosed to have severe PPO and multiple vertebral compression fractures and was prescribed risedronate 35 mg/week, calcium, and vitamin D. The other patient was a 36-year-old woman diagnosed with PPO and vertebral fractures at the third week postpartum. She was also treated with enoxaparin 60 mg/day during her pregnancy. Severe osteoporosis in L vertebras and height losses indicative for compression fractures in T5-8, T11-12, and L2-5 vertebras were detected by DEXA and MRI, respectively. She was treated with calcitonin 200 U/day, calcium, and vitamin D. These findings suggest that vertebral compression fractures and PPO may be one of the causes of severe back pain in postpartum patients. Treatment with LMWH during pregnancy might be considered as a new risk factor for this rare condition.

  7. Supracondylar humerus fractures in children treated with closed reduction and percutaneous pinning.

    PubMed

    Scaglione, Michelangelo; Giovannelli, Daniele; Fabbri, Luca; Dell'omo, Dario; Goffi, Andrea; Guido, Giulio

    2012-08-01

    Supracondylar fractures of the humerus in children are important for frequency and type of associated serious complications. The management of this kind of fractures is still controversial (Skaggs et al. in J Bone Joint Surg Am 86:702-707, 2004; Kalllio et al. in J Pediatr Orthop 12:11-15, 1992). We are going to present our experience in the treatment of supracondylar humeral fracture in children. In the Orthopedic Department of Pisa, we treated 150 cases from 1989 to 2006. We are used to perform, emergency or within 12 h, reduction and two lateral-entry percutaneous pins fixation. The mean age was 7.5 years. We checked 125 cases, because we excluded all the cases with follow up less then 5 years. The mean follow up was 8.2 years. We used Gartland classification modified by Wilkins. We evaluated 125 cases by using the Flynn classification: 100 % of patients did not have impairment of the elbow joint mobility. We had seven valgus deviation, one of which was more then 10°. We also had 17 varus deviations, 11 of which were not over 8° and only 2 of them were 15°. The average value of the joint Baumann angle was calculated as great as 16°. The obtained results were classified as very good 80 %, good 11 %, sufficiently good 6 %, and bad 3 %. In our experience, all the fractures type II and III by Gartland have to be treated within 12 h, with closed reduction and stabilization with lateral-entry K-wire technique. The conservative treatment by cast is indicated only in type I fracture. The trans olecranic treatment is not realizable, for the stiffness which can occur, for the risk of iatrogenic ulnar nerve lesion, and for long-time hospitalization. The open reduction remains the first choice treatment for exposed or nonreducible fractures, and in cases of vascular injury.

  8. Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Wei; Ho, Yi-Hung; Peng, Yao-Te; Chang, Chih-Han; Li, Chun-Ting

    2016-12-02

    This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.

  9. Risk factors for postoperative infections in patients with hip fracture treated by means of Thompson arthroplasty.

    PubMed

    García-Alvarez, F; Al-Ghanem, R; García-Alvarez, I; López-Baisson, A; Bernal, M

    2010-01-01

    Specific conditions associated with surgery may predispose elderly people to septic complications after hip fracture surgery. This study investigated the risk factors predisposing infection in aged patients with subcapital hip fracture. We performed a prospective study of 290 patients with displaced subcapital hip fracture, operated by means of Thompson hip hemi-arthroplasty (83.5% fractures in women). The mean age was 85.42+/-6.06 years (ranging from 69 to 104). Follow-up was realized until death or at least for 2 years. The chi(2) test, analysis of variance, Kruskal-Wallis test, correlation analysis and the Spearman test were applied. Odds ratios (OR) were calculated. During the hospital stay, there were diagnosed 94 urinary tract infections, 25 pneumonias, 50 superficial wound infections, 11 deep wound infections. Transfusions were made in 120 patients (in average: 2.54+/-1.45 units of red cell concentrate/transfused patient). Transfusion appeared to be correlated with superficial wound infection (OR=1.96), urinary infection (OR=1.76) and pneumonia (OR=2.85). Higher number of days waiting for surgery were related significantly with pneumonia (9.8+/-7.44 days vs. 6.39+/-3.75), or urinary tract infection (7.76+/-4.39 days vs. 6.17+/-4.14). We concluded that the transfusion and longer waiting time for surgery have been associated with the septic complications in elderly patients treated surgically for hip fracture.

  10. In vitro study to compare impact fracture resistance of intact root-treated teeth.

    PubMed

    McDonald, A V; King, P A; Setchell, D J

    1990-11-01

    The aim of this in vitro study was to determine the effect on impact fracture resistance of three methods for restoration of root-treated lower incisor teeth with otherwise intact natural crowns. In a control group (Group I) laterally condensed gutta-percha filled the entire root canal, whereas part of the root filling was removed to enable insertion of a 1 mm diameter post in the other two groups. Stainless steel posts were placed in Group II and experimental carbon fibre reinforced carbon (CFRC) in Group III. A composite resin luting agent was used to lute the posts, and standardized composite resin restorations were placed in each access cavity. Fifteen specimens of each group were tested to failure with a single impact force applied at 90 degrees to the mid-point inciso-cervically on the labial surface. The peak force, peak energy, and first peak total energy required to fracture each specimen were recorded. The results showed no significant difference between the three groups, nor was a difference in the mode or site of fracture observed. The results suggested that there is no advantage from the point of view of fracture mechanics in 'restoring' intact root-treated teeth with either stainless steel or carbon fibre reinforced carbon rods.

  11. The Biological Metallic versus Metallic Solution in Treating Periprosthetic Femoral Fractures: Outcome Assessment

    PubMed Central

    Carta, Serafino; Fortina, Mattia; Riva, Alberto; Manzi, Enrico

    2016-01-01

    Introduction. The periprosthetic fracture of the femur is, in order of frequency, the fourth leading cause (5.9%) of surgical revision. Our study aims to demonstrate how the grafting of bone splint betters the outcomes. Materials. We treated 15 periprosthetic femoral fractures divided into two groups: PS composed of 8 patients treated with plates and splints and PSS involving 7 patients treated only with plates. The evaluation criteria for the two groups during the clinical and radiological follow-up were the quality of life measured by the Short Form (36) Health Survey (SF-36), Harris Hip Score (HHS), Modified Cincinnati Rating System Questionnaire (MCRSQ), bone healing measured by the Radiographic Union Score (RUS), postoperative complications, and mortality. The evaluation endpoint was set at 24 months for both groups (p < 0.05). Results. The surgery lasted an average of 124.5 minutes for the PS group and 112.6 minutes for the PSS. At 24 months all clinical and radiographic scores were p < 0.05 for the PS group. During follow-up 4 patients (2 in each group) died of causes not related to surgery. Conclusions. The use of the metal plate as opposed to cortical allogenic splint should be taken into consideration as a noteworthy point for periprosthetic femoral fractures. PMID:27990462

  12. The Biological Metallic versus Metallic Solution in Treating Periprosthetic Femoral Fractures: Outcome Assessment.

    PubMed

    Carta, Serafino; Fortina, Mattia; Riva, Alberto; Meccariello, Luigi; Manzi, Enrico; Di Giovanni, Antonio; Ferrata, Paolo

    2016-01-01

    Introduction. The periprosthetic fracture of the femur is, in order of frequency, the fourth leading cause (5.9%) of surgical revision. Our study aims to demonstrate how the grafting of bone splint betters the outcomes. Materials. We treated 15 periprosthetic femoral fractures divided into two groups: PS composed of 8 patients treated with plates and splints and PSS involving 7 patients treated only with plates. The evaluation criteria for the two groups during the clinical and radiological follow-up were the quality of life measured by the Short Form (36) Health Survey (SF-36), Harris Hip Score (HHS), Modified Cincinnati Rating System Questionnaire (MCRSQ), bone healing measured by the Radiographic Union Score (RUS), postoperative complications, and mortality. The evaluation endpoint was set at 24 months for both groups (p < 0.05). Results. The surgery lasted an average of 124.5 minutes for the PS group and 112.6 minutes for the PSS. At 24 months all clinical and radiographic scores were p < 0.05 for the PS group. During follow-up 4 patients (2 in each group) died of causes not related to surgery. Conclusions. The use of the metal plate as opposed to cortical allogenic splint should be taken into consideration as a noteworthy point for periprosthetic femoral fractures.

  13. Inversion of the acetabular labrum triggers rapidly destructive osteoarthritis of the hip: representative case report and proposed etiology.

    PubMed

    Fukui, Kiyokazu; Kaneuji, Ayumi; Fukushima, Mana; Matsumoto, Tadami

    2014-12-01

    The pathophysiology of rapidly destructive osteoarthritis (OA) of the hip is unknown. This study documented cases of inversion of the acetabular labrum, which has clinicoradiologic features similar to those of initial-stage rapidly destructive hip OA. Our study was based on a prospective review of data for 9 patients with rapidly destructive hip OA. Intraoperative findings showed that the anterosuperior portion of the acetabular labrum had inverted into the articular space, along with many fragments of articular cartilage, in all patients. Subchondral insufficiency fractures of the femoral heads were seen just under the inverted labra in 8 of the 9 patients. Inversion of the acetabular labrum may be involved in rapid joint-space narrowing and subchondral insufficiency fracture in rapidly destructive hip OA.

  14. Retained Sponge: A Rare Complication in Acetabular Osteosinthesis

    PubMed Central

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Moran-Blanco, Luz María; Vaquero-Martín, Javier

    2015-01-01

    Retained sponges after a surgical treatment of polytrauma may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a 35-year-old man transferred from another hospital, that sustained a open acetabular fracture. The fracture was reduced through a limited ilio-inguinal approach. After 4 days, he presented massive wound dehiscence of the surgical approach. An abdominal CT scan showed, lying adjacent to the outer aspect of the left iliac crest, a mass of 10 cm, identified as probable foreign body. The possibility of this rare complication should be in the differential diagnosis of any postoperative patient who presents with pain, infection, or palpable mass. PMID:26312116

  15. Impact of attention deficit hyperactivity disorder therapy on fracture risk in children treated in German pediatric practices.

    PubMed

    Jacob, L; Kostev, K

    2017-04-01

    Two thousand eight hundred ninety-four children and adolescents treated by 243 pediatricians were analyzed. Patients receiving attention deficit hyperactivity disorder (ADHD) medications were at a lower risk of fractures than patients without ADHD medications. The strongest impact was in the age group of 6-9 years. Finally, there was a significant association between therapy duration and fracture risk.

  16. Lunate Osteochondral Fracture Treated by Excision: A Case Report and Literature Review

    PubMed Central

    Saberi, Sadegh; Arabzadeh, Aidin; Farhoud, Amir Reza

    2016-01-01

    Introduction Lunate fracture is a rare injury. Most reports are associated with other wrist injuries such as perilunate dislocation and distal radius fracture. Isolated lunate fracture has been reported even more rarely. The choice of treatment and outcomes are consequently undetermined. Case Presentation In this case report we will describe a lunate avulsion fracture as an isolated injury after a fall from nine meters treated operatively by excision of the comminuted avulsed fragment. After 33 months of follow-up radiographs showed no sign of degenerative joint disorder on simple X-ray, but slight Volar Intercalated Segment Instability (VISI) by a capitolunate angle of 26 degrees was noted. Clinically, the patient was pain free near full wrist and forearm range of motion and could perform his previous vocational and recreational tasks without any limitations. Conclusions Despite apparently good short and mid-term clinical outcome, slight volar intercalated segment instability after 33 months of follow-up revealed that lunotriquetral ligament function was probably lost, which led to static instability. This ligament injury may be missed primarily. Excision of the avulsed osteochondral fragment should be the last option of treatment and most attempts should be tried to fix and/or restore the normal anatomy of ligamentous structure. PMID:27626007

  17. Tibial spine fractures: an analysis of outcome in surgically treated type III injuries.

    PubMed

    Mulhall, K J; Dowdall, J; Grannell, M; McCabe, J P

    1999-05-01

    We analysed the outcome of open reduction and internal fixation of type III tibial spine fractures, assessing treatment and determining a treatment protocol. A total of 10 patients presented over 3 years to our institution with a mean age of 15 years (range 10-21), a male-to-female ratio of 8:2. left to right 6:4 and anterior to posterior spine fracture 9:1. Only one patient had associated meniscal injury noted at arthroscopy (no treatment required). The mode of injury was road traffic accidents four, sports injuries three and falls three. The mean follow-up was 9 months. There were seven excellent results and three good results. Those patients with good results exhibited either minimal quadriceps weakness, extensor lag (< 10 degrees) or antero-posterior laxity. This reflects the experience of other authors in dealing with these injuries in younger patients. There is widespread agreement that types I and II should be treated by plaster cast alone and that is also the policy at our institution. We recommend a routine treatment protocol in type III injuries of (1) examination under anaesthesia, (2) arthroscopy (evaluating the fracture, cruciate integrity and other associated injuries), (3) open reduction and screw fixation and (4) vigorous physiotherapy/rehabilitation of all type III fractures, as we feel this provides the best possible outcome in these injuries.

  18. Bicondylar tibial plateau fractures treated with fine-wire circular external fixation.

    PubMed

    Ferreira, N; Marais, L C

    2014-04-01

    Bicondylar tibial plateau fractures are serious injuries to a major weight-bearing joint. These injuries are often associated with severe soft tissue injuries that complicate surgical management. We reviewed 54 consecutive patients who sustained bicondylar tibial plateau fractures that were treated with limited open reduction and cannulated screw fixation combined with fine-wire circular external fixation. Forty-six patients met the inclusion criteria of this retrospective review. Eight patients were excluded because they did not complete a minimum of 1-year follow-up. Thirty-six patients had Schatzker type-VI, and ten patients had Schatzker type-V fractures. All fractures were united without loss of reduction; there were no incidences of wound complications, osteomyelitis or septic arthritis. The average Knee Society Clinical Rating Score was 81.6, translating to good clinical results. Minor pin track infection was the most common complication encountered. This review concludes that fine-wire circular external fixation, combined with limited open reduction and cannulated screw fixation, consistently produces good functional results without serious complications.

  19. Analysis of gene expression profiles in healing rat fractures treated with nail and plate fixation.

    PubMed

    Wang, S D; Li, X L; Liu, H P

    2014-10-20

    To compare fracture healing therapies, the gene expression profiles of rat fracture samples treated with nail and plate fixation were analyzed at 1 day, 3 days, 1 week, 2 weeks, 4 weeks, and 6 weeks after surgery. The gene expression profiles GSE1685, which include 19 samples, were downloaded from the Gene Expression Omnibus database. After preprocessing, the gene expression profiles were subjected to time series analysis using the Short Time-series Expression Miner software, and the significantly differentially expressed gene (DEG) sets were selected. Further, the distributions of those DEG sets on the corresponding chromosomes were identified using the functional classification tool. Finally, the DEGs were subjected to function and pathway enrichment analysis. DEG analysis indicated that the number of DEGs (854 genes) from nail fixation was significantly lower than that of DEGs (1029 genes) from plate fixation. The DEGs were mainly enriched in cell proliferation, cellular localization, and response to wounding functions. Several critical DEGs expressed during the fracture healing process were screened, and 2 common pathways were enriched for the DEGs in the nail fixation and plate fixation. These DEGs and pathways may be potential targets or predictive markers during fracture healing.

  20. Colles' fracture treated with non-bridging external fixation: a 1-year follow-up.

    PubMed

    Andersen, J K; Høgh, A; Gantov, J; Vaesel, M T; Hansen, T Baek

    2009-08-01

    The results in 75 of 105 patients with Older type II/III (AO type A2.2, A3.1, A3.2) Colles' fractures, treated with non-bridging external fixation are presented. The mean age was 67.8 years, and all patients were followed prospectively for 12 months with radiological and functional assessment. No statistically significant loss of radial length, angulation or inclination was seen between the postoperative reduction and the 1-year follow-up examination. The clinical results after 1 year were 66 (88%) excellent/good, nine (12%) fair and 0 (0%) poor according to the modified Gartland and Werley score. Mean visual analogue scale pain score after 1 year was 0.8. In three patients (4%), re-displacement of the fracture occurred and was treated with plating. Non-bridging external fixation offers a reliable method of maintaining radiological reduction of Older type II/III fractures of the distal radius and gives a good functional outcome after 1 year.

  1. Optimization of acetabular component orientation using DOE

    NASA Astrophysics Data System (ADS)

    Krepelka, Mircea; Toth-Taşcǎu, Mirela

    2012-09-01

    Stress shielding is increasingly recognized as an important cause of acetabular component failure. Several studies have been focused on improving the acetabular component placement to reduce the risk of dislocation, impingement and range of motion but little is known of its influence on implant-bone interface pressures. This study employs experimental design, 3D reconstruction and FE simulation to identify the most significant factors for acetabular component behavior and predict the best configuration of acetabular spatial orientation angles within the constraints of the Lewinnek's safe zone in order to minimize peak contact pressures. Data analysis by response surface method revealed that the magnitude of periacetabular pressures was significantly reduced by the anteversion angle at its lowest value as well as the abduction angle located at the central point value, which corresponded to a 40° abduction and 5° anteversion of cup orientation.

  2. Triplane fracture of distal radius treated surgically: case report and review of the literature.

    PubMed

    Mingo-Robinet, Juan; Torres-Torres, Miguel; Gonzalez-Rodriguez, Manuel

    2014-05-01

    Only four cases of triplane distal radius fracture have been described in the literature. We report the first that has been treated with open reduction and internal fixation. A 15-year-old boy sustained a triplane fracture of the distal radius. After an unsuccessful attempt at closed reduction, open reduction and internal fixation were performed. Six months after injury, the patient is asymptomatic, but radiographs show a partial growth arrest. The goal of treatment is to achieve anatomic reduction of the articular surface. In this case interposed periosteum prevented anatomic reduction, requiring open reduction and internal fixation. Because of the patient's advanced age the partial physeal arrest should advance to complete arrest before length impairment or occurrence of angular deformity.

  3. Importance of maintaining the basic stress pathway above the acetabular dome during acetabular reconstruction.

    PubMed

    Nie, Yong; Pei, Fuxing; Shen, Bin; Kang, Pengde; Li, Zongming

    2016-01-01

    The basic stress pathway above the acetabular dome is important for the maintenance of implant stability in press-fit acetabular reconstruction of total hip arthroplasty. However, information on the basic stress pathway and its impact factors remains unclear. The objective of this study was to investigate the effects of the orientations and positions of the acetabular component on the basic stress pathway. The basic stress pathway above the acetabular dome was defined as two parts: 3D basic trabecular bone stress distribution and quantified basic cortical bone stress level, using two subject-specific finite element normal hip models. The effects were then analysed by generating 32 reconstructed acetabular cases with different cup abduction and anteversion angles within a range of 35-50° and 10-25°, respectively, and 12 cases with different hip centre heights within a range of 0-15 mm above the acetabular dome. The 3D trabecular stress distribution decreased remarkably in all cases, while the 80% of the basic cortical bone stress level was maintained in cases when the acetabular component was positioned at 10° or 15° anteversion and 40° or 45° abduction angles. The basic stress pathway above the acetabular dome was disturbed when the superior displacement of the hip centre exceeded 5 mm above the anatomical hip centre. Positioning the acetabular component correctly contributes to maintain the stress balance between the acetabular cup and the bone during acetabular reconstruction, thus helping restore the normal hip biomechanics and preserve the stability of the implants.

  4. FRACTURES OF THE DISTAL EXTREMITY OF THE TIBIA TREATED WITH INTRAMEDULLARY NAIL OR BRIDGE PLATE: COMPARISON OF RADIATION EXPOSURE DURATION BETWEEN THE TWO METHODS

    PubMed Central

    Labronici, Pedro José; Lyra, Fábio Soares; Moreira, Ildeu Leite; Hoffmann, Rolix; Franco, José Sergio; de Toledo Lourenço, Paulo Roberto Barbosa; Labronici, Gustavo José

    2015-01-01

    Objective: To compare the duration of exposure to radiation among patients with fractures of the distal third of the tibia treated with an intramedullary nail or with a bridge plate. Methods: Intramedullary nails were used for 33 fractures, and bridge plates were used for 41 fractures. In the nail group, according to the AO classification, 14 patients had type A fractures, 15 had type B and four had type C. Twelve patients had closed fractures and 21 had open fractures. In the plate group, 10 patients had type A fractures, 22 had type B and nine had type C. Twenty-seven patients had closed fractures and 14 had open fractures. Results: There was a significant difference in the duration of exposure to radiation between the patients treated using a nail and those treated using a plate (p = 0.0001). The group treated using a nail had significantly greater exposure to radiation than did the group treated using a plate. Comparing the type of fracture (A, B or C), it was observed that there was no significant difference in the duration of exposure to radiation between the nail technique (p = 0.19) and the plate technique (p = 0.80). Conclusion: Fractures of the distal third of the tibia treated with an intramedullary nail present significantly greater exposure to radiation than do fractures treated with a bridge plate, independent of the fracture type. PMID:27022530

  5. Sport related proximal femoral fractures: a retrospective review of 31 cases treated in an eight year period

    PubMed Central

    Habernek, H.; Schmid, L.; Frauenschuh, E.

    2000-01-01

    In an eight year period, 31 patients with proximal femoral fractures resulting from sports accidents were treated by implantation of either a Gamma nail or a dynamic hip screw. Return to work or sports and the time to bone healing did not differ very much between the treatments. Gamma nailing was clearly the best with regard to stability and time to full mobilisation (4.5 days), but required 39 minutes to perform compared with insertion of a dynamic hip screw (27 minutes). The incidence of complications and malalignments did not differ very much between the two, although, when Gamma nailing was first used in the authors' clinic, more intraoperative complications occurred than with the dynamic hip screw. Stable pertrochanteric fractures may be treated with a dynamic hip screw. Unstable pertrochanteric or subtrochanteric fractures are treated with a Gamma nail at the authors' institution. Key Words: femur; fracture; Gamma nail; dynamic hip screw; skiing; mountain biking PMID:10690452

  6. Outcome of porous tantalum acetabular components for Paprosky type 3 and 4 acetabular defects.

    PubMed

    Batuyong, Eldridge D; Brock, Hugh S; Thiruvengadam, Nikhil; Maloney, William J; Goodman, Stuart B; Huddleston, James I

    2014-06-01

    Porous tantalum acetabular implants provide a potential solution for dealing with significant acetabular bone loss. This study reviews 24 acetabular revisions using tantalum implants for Paprosky type 3 and 4 defects. The mean Harris Hip Score improved from 35 ± 19 (range, 4-71) to 88 ± 14 (range, 41-100), p < 0.0001. Postoperative radiographs showed radiolucent lines in 14 hips with a mean width of 1.3 ± 1.0 mm (range, 0.27-4.37 mm). No gaps enlarged and 71% of them disappeared at a mean of 13 ± 10 months (range, 3-29 months). At a mean follow-up of 37 ± 14 months (range, 24-66 months), 22 reconstructions showed radiograpic evidence of osseointegration (92%). The two failures were secondary to septic loosening. When dealing with severe acetabular bone loss, porous tantalum acetabular components show promising short-term results.

  7. Proximal screws placement in intertrochanteric fractures treated with external fixation: comparison of two different techniques

    PubMed Central

    2011-01-01

    Background To compare two different techniques of proximal pin placement for the treatment of intertrochanteric fractures in elderly patients utilizing the Orthofix Pertrochanteric Fixator. Methods Seventy elderly high-risk patients with an average age of 81 years were treated surgically for intertrochanteric fracture, resulting from a low energy trauma. Patients were randomly divided in two groups regarding to the proximal pin placement technique. In Group A the proximal pins were inserted in a convergent way, while in Group B were inserted in parallel. Results All fractures healed uneventfully after a mean time of 98 days. The fixator was well accepted and no patient had significant difficulties while sitting or lying. The mean VAS score was 5.4 in group A and 5.7 in group B. At 12 months after surgery, in group A the average Harris Hip Score and the Palmer and Parker mobility score was 67 and 5.8, respectively. In group B, the average Harris Hip Score and the Palmer and Parker mobility score was 62 and 5.6, respectively. No statistically significant difference was found regarding the functional outcome. The mean radiographic exposure during pin insertion in Group A and Group B was 15 and 6 seconds, respectively. The difference between the two groups, regarding the radiographic exposure, was found to be significant. Conclusion Proximal screw placement in a parallel way is simple, with significant less radiation exposure and shorter intraoperative duration. In addition, fixation stability is equal compared to convergent pin placement. PMID:21939534

  8. Malleolar fractures and their ligamentous injury equivalents have similar outcomes in supination-external rotation type IV fractures of the ankle treated by anatomical internal fixation.

    PubMed

    Berkes, M B; Little, M T M; Lazaro, L E; Sculco, P K; Cymerman, R M; Daigl, M; Helfet, D L; Lorich, D G

    2012-11-01

    It has previously been suggested that among unstable ankle fractures, the presence of a malleolar fracture is associated with a worse outcome than a corresponding ligamentous injury. However, previous studies have included heterogeneous groups of injury. The purpose of this study was to determine whether any specific pattern of bony and/or ligamentous injury among a series of supination-external rotation type IV (SER IV) ankle fractures treated with anatomical fixation was associated with a worse outcome. We analysed a prospective cohort of 108 SER IV ankle fractures with a follow-up of one year. Pre-operative radiographs and MRIs were undertaken to characterise precisely the pattern of injury. Operative treatment included fixation of all malleolar fractures. Post-operative CT was used to assess reduction. The primary and secondary outcome measures were the Foot and Ankle Outcome Score (FAOS) and the range of movement of the ankle. There were no clinically relevant differences between the four possible SER IV fracture pattern groups with regard to the FAOS or range of movement. In this population of strictly defined SER IV ankle injuries, the presence of a malleolar fracture was not associated with a significantly worse clinical outcome than its ligamentous injury counterpart. Other factors inherent to the injury and treatment may play a more important role in predicting outcome.

  9. [Bone cement dry prosthetic with internal fixation treat senile osteoporotic femoral fractures].

    PubMed

    Jiang, Y; Rong, X X; Chen, P; Xu, Y J; Zhu, G X

    2017-03-01

    Objective: To explore the treatment of senile osteoporotic femoral fractures after using internal fixation of bone cement dry prosthetic. Methods: Twelve patients aged from 74 to 94 years with mean age of (84.0±2.5) years with internal fixation of bone cement dry prosthetic surgery who were treated at Department of Orthopaedics in Nanjing Medical University Affiliated Wuxi Second Hospital between May 2013 and May 2015 were retrospectively analyzed. There were 8 male and 4 female, 10 cases of tumble and 2 cases of traffic injury. The fracture types with AO type included 1 case of A1 type, 5 cases of A2 type, 3 cases of A3 type, 1 case of B1 type, 2 cases of B2 type. The steel plate internal fixation with bone cement dry prosthetic method was chosen to treat senile severe femoral fracture. Postoperative observation of postoperative pain assessment, hip joint activity and walking ability were evaluated. Paired simple t test and Wilcoxon rank sum test were used to compare the differences of pain score and the ability to walk. Results: Twelve cases received an average of (16.0±3.6) months follow-up. The average hospitalization days are (9.0±1.4) days and average of intraoperative time was (68.0±10.6) minutes. Intraoperative blood loss compared to normal was (106.0±24.2) ml. Patients began walking load and activities in two weeks. The gait and joint activities gradually restored and there were no obvious deformity and no loose internal fixation. All of the patients didn't have fracture shift with breaking plates or screws deformation and have no bone cement reaction. The walking ability was (4.1±0.9) points, the hip joint activities were 98.5°±7.7° and pain scores were 1.22±0.58 by Holden grading standards. The differences of walking ability (Z=-3.126, P<0.05) and pain scores (t=23.047, P<0.001) between pre- and post-operative were statistically significant. One patient had contralateral hip pain, 2 patients had lateral thigh pain, 10 patients returned to

  10. Surgical interventions to treat humerus shaft fractures: A network meta-analysis of randomized controlled trials

    PubMed Central

    Wang, Jia; Meng, Xiao-Hui; Zeng, Xian-Tie; Kan, Shi-Lian

    2017-01-01

    Background There are three main surgical techniques to treat humeral shaft fractures: open reduction and plate fixation (ORPF), intramedullary nail (IMN) fixation, and minimally invasive percutaneous osteosynthesis (MIPO). We performed a network meta-analysis to compare three surgical procedures, including ORPF, IMN fixation, and MIPO, to provide the optimum treatment for humerus shaft fractures. Methods MEDLINE, EMBASE, Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, and Cochrane library were researched for reports published up to May 2016. We only included randomized controlled trials (RCTs) comparing two or more of the three surgical procedures, including the ORPF, IMN, and MIPO techniques, for humeral shaft fractures in adults. The methodological quality was evaluated based on the Cochrane risk of bias tool. We used WinBUGS1.4 to conduct this Bayesian network meta-analysis. We used the odd ratios (ORs) with 95% confidence intervals (CIs) to calculate the dichotomous outcomes and analyzed the percentages of the surface under the cumulative ranking curve. Results Seventeen eligible publications reporting 16 RCTs were included in this study. Eight hundred and thirty-two participants were randomized to receive one of three surgical procedures. The results showed that shoulder impingement occurred more commonly in the IMN group than with either ORPF (OR, 0.13; 95% CI, 0.03–0.37) or MIPO fixation (OR, 0.08; 95% CI, 0.00–0.69). Iatrogenic radial nerve injury occurred more commonly in the ORPF group than in the MIPO group (OR, 11.09; 95% CI, 1.80–124.20). There were no significant differences among the three procedures in nonunion, delayed union, and infection. Conclusion Compared with IMN and ORPF, MIPO technique is the preferred treatment method for humeral shaft fractures. PMID:28333947

  11. Performance-based Outcomes of Inpatient Rehabilitation Facilities Treating Hip Fracture Patients in the United States

    PubMed Central

    Baernholdt, Marianne; Anderson, Ruth A.; Merwin, Elizabeth I.

    2015-01-01

    Objective To examine the influence of facility and aggregate patient characteristics of inpatient rehabilitation facilities (IRFs) on performance-based rehabilitation outcomes in a national sample of IRFs treating Medicare beneficiaries with hip fracture. Design Secondary data analysis. Setting U.S. Medicare-certified IRFs (N=983). Participants 983 US Medicare-certified IRFs. Data included 34,364 patient records of Medicare beneficiaries admitted in 2009 for rehabilitation after hip fracture. Main Outcome Measures Performance-based outcomes included mean motor function on discharge, mean motor change (mean motor score on discharge minus mean motor score on admission) and percentage discharged to the community. Results Higher mean motor function on discharge was explained by aggregate characteristics of hip fracture patients (lower age [p=0.009], lower percentage of Blacks [p<0.001] and Hispanics [p<0.001], higher percentage of females [p<0.030], higher motor function on admission [p<0.001], longer length of stay [p<0.001]) and facility characteristics (freestanding [p<0.001], rural [p<0.001], for-profit [p=0.048], and smaller IRFs [p=0.041]). The findings were similar for motor change, but motor change was also associated with lower mean cognitive function on admission (0.008). Higher percentage discharged to the community was associated with aggregate patient characteristics (lower age [p<0.001], lower percentage of Hispanics [p=0.009], higher percentage of patients living with others [p<0.001], and higher motor function on admission [p<0.001]). No facility characteristics were associated with percentage discharged to the community. Conclusion Performance-based measurement offers health policymakers, administrators, clinicians, and consumers a major opportunity for securing health system improvement by benchmarking or comparing their outcomes to other similar facilities. These results might serve as the basis for benchmarking and quality-based reimbursement to

  12. Functional outcomes, morbidity, mortality, and fracture healing in 58 consecutive patients with geriatric odontoid fracture treated with cervical collar or posterior fusion.

    PubMed

    Molinari, William J; Molinari, Robert W; Khera, Oner A; Gruhn, William L

    2013-03-01

    Controversy exists as to the most effective management option for elderly patients with type II odontoid fractures. The purpose of this study is to evaluate outcomes associated with rigid cervical collar and posterior fusion surgery. Patients with ≥ 50% odontoid displacement were treated with posterior fusion surgery including C1-2 (PSF group, n = 25, average age = 80 years). Patients with < 50% odontoid displacement were treated with a rigid cervical collar for 12 weeks (collar group, n = 33, average age = 83 years). These inhomogeneous groups were followed for an average of 14 months. Fracture healing rates were higher in the operative group (28% versus 6%). Neck Disability Index scores were slightly lower in the nonoperative group (13 versus 18.3, p = 0.23). Analogue pain scores were also slightly lower in the nonoperative group (1.3 versus 1.9, p = 0.26). The mortality rate was 12.5% in the collar group and 20% in the operative group. Complications were higher in the operative group (24% versus 6%). Rates of type II odontoid facture healing and stability appear to be higher in geriatric patients treated with posterior fusion surgery. Fracture healing and stability did not correlate with improved outcomes with respect to levels of pain, function, and satisfaction. Mortality and complication rates are lower in those patients with lesser-displaced fractures who are treated with a cervical collar and early mobilization.

  13. Acetabular blood flow during total hip arthroplasty

    PubMed Central

    ElMaraghy, Amr W.; Schemitsch, Emil H.; Waddell, James P.

    2000-01-01

    Objective To determine the immediate effect of reaming and insertion of the acetabular component with and without cement on periacetabular blood flow during primary total hip arthroplasty (THA). Design A clinical experimental study. Setting A tertiary referral and teaching hospital in Toronto. Patients Sixteen patients (9 men, 7 women) ranging in age from 30 to 78 years and suffering from arthritis. Intervention Elective primary THA with a cemented (8 patients) and noncemented (8 patients) acetabular component. All procedures were done by a single surgeon who used a posterior approach. Main outcome measure Acetabular bone blood-flow measurements made with a laser Doppler flowmeter before reaming, after reaming and after insertion of the acetabular prosthesis. Results Acetabular blood flow after prosthesis insertion was decreased by 52% in the noncemented group (p < 0.001) and 59% in the cemented group (p < 0.001) compared with baseline (prereaming) values. Conclusion The significance of these changes in periacetabular bone blood flow during THA may relate to the extent of bony ingrowth, periprosthetic remodelling and ultimately the incidence of implant failure because of aseptic loosening. PMID:10851413

  14. Recurrent bilateral metatarsal "stress-and-insufficiency" fractures in a levodopa-treated young woman with Parkinson's disease.

    PubMed

    Verdet, M; Nicolau, J; Lefaucheur, R; Maltête, D; Derrey, S; Daragon, A

    2013-03-01

    Levodopa treatment of Parkinson's disease is very effective, but many types of adverse events can complicate the disease course, especially dyskinesias. As reported by Lee et al. (Calcif Tissue Int 86:132-41, 2010), levodopa intake is associated with increased homocysteinemia that is known to be linked to poorer bone quality and, consequently, osteoporotic fractures. Herein, we report the case of a young woman who suffered recurrent metatarsal fractures in the context of levodopa-treated early-onset Parkinson's disease.

  15. Comparison of fracture resistance and failure pattern of endodontically treated premolars with different esthetic onlay systems: An in vitro study

    PubMed Central

    Mynampati, Praffulla; Babu, Mandava Ramesh; Saraswathi, Devabhaktuni Disha; Kumar, Janga Ravi; Gudugunta, Leneena; Gaddam, Divya

    2015-01-01

    Aim: To compare the fracture resistance and modes of failures of three different aesthetic MOD onlays on endodontically treated premolars. Materials and Methods: Forty sound maxillary premolars were selected of which 10 untreated teeth were taken as control (Group I). The other thirty premolars were subjected to standardized MOD onlay preparations and root canal treatments and divided into 3 equal groups. Onlays were prepared in Group II- Indirect composite, Group III- Lithium Disilicate ceramic and Group IV- Full Zirconia. All onlays were cemented using Multilink Automix. All the 40 samples were subjected to fracture resistance testing on Universal testing machine. Also fractured specimens were observed under stereo-microscope for modes of failure. Results: Group IV presented the highest fracture resistance. Groups II and III presented no significant difference in fracture resistance from each other (P > 0.05). Group II and Group III showed significantly lower fracture resistance values than Group I. Coming to modes of failure, only Group IV had showed no cracks in any of the restorations. Conclusion: Full Zirconia MOD onlays increased the fracture resistance of endodontically treated premolars to a significantly higher level than the sound teeth. PMID:25829694

  16. Influence of ferrule preparation with or without glass fiber post on fracture resistance of endodontically treated teeth

    PubMed Central

    de LIMA, Alexandra Furtado; SPAZZIN, Aloísio Oro; GALAFASSI, Daniel; CORRER-SOBRINHO, Lourenço; CARLINI-JÚNIOR, Bruno

    2010-01-01

    Objective This study evaluated the effect of ferrule preparation (Fp) on the fracture resistance of endodontically treated teeth, restored with composite resin cores with or without glass fiber posts. Material and Methods Forty-four bovine teeth were sectioned 19 or 17 mm (2 mm ferrule) from the apex, endodontically treated and assigned to four groups (n = 11): Group 1: Fp and post; Group 2: Fp and without post; Group 3: without Fp and with post; Group 4: without Fp and without post. All specimens were restored with composite resin core and metal crown. Specimens were subjected to fracture resistance testing in a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed by two-way ANOVA and Tukey’s tests (α=0.05). Results The mean fracture resistance values were as follows: Group 1: 573.3 N; Group 2: 552.5 N; Group 3: 275.3 N; Group 4: 258.6 N. Significantly higher fracture resistance was found for the groups with Fp (p<0.001). Conclusion There was no statistically significant interaction between the "Fp" and "post" factors (p = 0.954). The ferrule preparation increased the fracture resistance of endodontically treated teeth. However, the use of glass fiber post showed no significant influence on the fracture resistance. PMID:20835570

  17. Occipital neuralgia after occipital cervical fusion to treat an unstable jefferson fracture.

    PubMed

    Kong, Seong Ju; Park, Jin Hoon; Roh, Sung Woo

    2012-12-01

    In this report we describe a patient with an unstable Jefferson fracture who was treated by occipitocervical fusion and later reported sustained postoperative occipital neuralgia. A 70-year-old male was admitted to our center with a Jefferson fracture induced by a car accident. Preoperative lateral X-ray revealed an atlanto-dens interval of 4.8mm and a C1 canal anterior-posterior diameter of 19.94mm. We performed fusion surgery from the occiput to C5 without decompression of C1. The patient reported sustained continuous pain throughout the following year despite strong analgesics. The pain dermatome was located mainly in the great occipital nerve territory and posterior neck. Magnetic resonance images revealed no evidence of cord compression, however a C1 lamina compressed dural sac and C2 root compression could not be excluded. We performed bilateral C2 root decompression via a C1 laminectomy. After decompression, bilateral C2 root redundancy was identified by palpation. After decompression surgery, pain was reduced. This case indicates that occipital neuralgia, suggesting the need for diagnostic block, should be considered in the differential diagnosis of patients with sustained occipital headache after occipitocervical fusion surgery.

  18. Comparative Study of Bipolar Hemiarthroplasty for Femur Neck Fractures Treated with Cemented versus Cementless Stem

    PubMed Central

    Choi, Jung-Yun; Kim, Joo-Hyung

    2016-01-01

    Purpose To compare and analyze clinical and radiologic outcomes of cemented versus cementless bipolar hemiarthroplasty for treatment of femur neck fractures. Materials and Methods A total of 180 patients aged 65 years and over older who underwent bipolar hemiarthroplasty for treatment of displaced femur neck fractures (Garden stage III, IV) from March 2009 to February 2014 were included in this study. Among the 180 patients, 115 were treated with cemented stems and 65 patients with cementless stems. Clinical outcomes assessed were: i) postoperative ambulatory status, ii) inguinal and thigh pain, and iii) complications. The radiologic outcome was femoral stem subsidence measured using postoperative simple X-ray. Results The cemented group had significantly lower occurrence of complications (postoperative infection, P=0.04) compared to the cementless group. There was no significant difference in postoperative ambulatory status, inguinal and thigh pain, and femoral stem subsidence. Conclusion For patients undergoing bipolar hemiarthroplasty, other than complications, there was no statistically significant difference in clinical or radiologic outcomes in our study. Selective use of cemented stem in bipolar hemiarthroplasty may be a desirable treatment method for patients with poor bone quality and higher risk of infections. PMID:28097110

  19. Acetabular pneumatocyst containing air-fluid level.

    PubMed

    Narváez, J A; Narváez, J; Rodríguez-Mijarro, M; Quintero, J C

    1999-01-01

    The presence of intraosseous gas most commonly occurs in osteomyelitis, vacuum phenomenon, and postsurgery or posttraumatic states. Several cases of subchondral gas-filled lesions, called pneumatocysts, have also been described in the sacroiliac joint and clavicle, none of them with intralesional air-fluid level. These pneumatocysts are innocuous lesions of uncertain origin. We describe one case of acetabular pneumatocyst containing air-fluid level in a 62-year-old man with long-standing ankylosing spondylitis involving hip joint. To our knowledge, this is the first reported case of a pneumatocyst in an acetabular location containing air-fluid level.

  20. Fractures

    MedlinePlus

    A fracture is a break, usually in a bone. If the broken bone punctures the skin, it is called an open ... falls, or sports injuries. Other causes are low bone density and osteoporosis, which cause weakening of the ...

  1. Fracture resistance of endodontically treated teeth restored with indirect composite inlay and onlay restorations – An in vitro study

    PubMed Central

    Alshiddi, Ibraheem F.; Aljinbaz, Amjad

    2015-01-01

    Objective The purpose of this in vitro study was to evaluate and compare the fracture resistance and fracture mode of extensive indirect inlay and onlay composite resin restorations performed for endodontically treated premolars. Materials and methods A total of 55 extracted maxillary premolars were randomly divided into four groups. The first group (n = 15) remained untreated to serve as a positive control; the second group (n = 15) was endodontically treated with inlay cavities prepared and restored with indirect composite inlay restorations; the third group (n = 15) was also endodontically treated with onlay cavities prepared and restored with indirect composite onlay restorations; and the fourth group (n = 10) was endodontically treated with mesio-occlusodistal (MOD) cavities prepared and left unrestored to serve as negative controls. Dual cure indirect composite resin was used to fabricate the inlay and onlay restorations performed for the second and third groups, respectively. All teeth were subjected to compressive axial loading test using a metal ball (6 mm in diameter) in a universal testing machine (Instron 1195) with a cross-head speed of 0.5 mm/min until a fracture occurred. Statistical analysis of fracture resistance and fracture mode were performed with analysis of variance (ANOVA) (α = 0.05) and Kruskal–Wallis (α = 0.05) tests, respectively. Results For the four treatment groups, the mean fracture resistance values were 1326.9 N, 1500.1 N, 1006.1 N, and 702.7 N, respectively. Statistical analyses showed no significant differences between the mean fracture resistance of the intact tooth group and the inlay restoration group (p > 0.05), while significant differences were observed between the mean fracture resistance of all the other groups (p < 0.05). The Kruskal–Wallis test showed statistically significant differences between the fracture modes of the four groups. Conclusion Within the limitations of this study

  2. Subchondral Insufficiency Fracture of the Femoral Head treated with Core Decompression and Bone Void Filler Support

    PubMed Central

    Patel, Hiren; Kamath, Atul F.

    2016-01-01

    Subchondral insufficiency fracture of the femoral head (SIFFH) is characterized by acute onset hip pain without overt trauma. It appears as a low intensity band with bone marrow edema on T1-weighted MRI. The most common course of treatment is protected weight bearing for a period of several weeks. Total hip arthroplasty (THA) has been commonly used if the patient does not respond to the initial protected weight bearing treatment. We present a case of a 48-year-old male with SIFFH who was treated with core hip decompression and bone void filler as a hip-preserving alternative to THA. The patient has an excellent clinical and radiographic result at final follow up. Core hip decompression with bone void filler is a less invasive alternative to THA, and may be a preferred initial treatment strategy for SIFFH in the young and active patient who has failed conservative measures. PMID:27517074

  3. The acetabular point: a morphological and ontogenetic study

    PubMed Central

    RISSECH, C.; SAÑUDO, J. R.; MALGOSA, A.

    2001-01-01

    The acetabular point was analysed by studying human pelvic bones from 326 individuals ranging from newborns to age 97 y. The bones were categorised into 3 groups according to the degree of fusion for the 3 elements of the pelvis: nonfused (59), semifused (5) and fused (262). The acetabular point in immature pelvic bones is clearly represented by the point of the fusion lines for each bony element at the level of the acetabular fossa. In adult pelvic bones the acetabular fossa has an irregular clover-leaf shape, the superior lobe being smaller than the anterior and posterior lobes. Cross-sectional analysis of acetabular morphology suggested that the acetabular point in adult pelvic bones is always represented by the indentation between the superior and the anterior lobes of the acetabular fossa. PMID:11465866

  4. Fracture severity of distal radius fractures treated with locking plating correlates with limitations in ulnar abduction and inferior health-related quality of life

    PubMed Central

    Tsitsilonis, Serafim; Machó, David; Manegold, Sebastian; Krapohl, Björn Dirk; Wichlas, Florian

    2016-01-01

    Introduction/background: The operative treatment of distal radius fractures has significantly increased after the introduction of locking plates. The aim of the present study was the evaluation of health-related quality of life, functional and radiological outcome of patients with distal radius fractures treated with the locking compression plate (LCP). Materials and methods: In the present study 128 patients (130 fractures) that were operatively treated with the LCP (2.4 mm/3.5 mm, Synthes®) were retrospectively evaluated. Mean follow-up was 22.7 months (SD 10.6). The fractures were radiographically evaluated (radial inclination, palmar tilt, ulnar variance) pre-, postoperatively and at the last follow-up visit. Range of motion (ROM) was documented. Grip strength was assessed with the use of a JAMAR dynamometer. The score for disabilities of the arm, shoulder and hand (DASH) and the Gartland-Werley score (GWS) were evaluated. Health-associated quality of life was assessed with use of SF-36 Health Survey. Results: Postoperative reduction was excellent; at the last follow-up visit only minimal reduction loss was observed. Except for pronation, a statistically significant decrease of ROM was present; in most cases that was not disturbing for the patients. The injured side achieved 83.9% of grip strength of the intact side. Mean DASH was 18.9 and mean GWS was 3.5. Health-associated quality of life was generally not compromised. However, limitations in ulnar abduction correlated with inferior quality of life. Fracture severity correlated with inferior quality of life, despite the absence of correlation with the functional and radiological outcome. Complication rate was low. Conclusions: Fracture severity seems to affect ulnar abduction and therefore patient quality of life, despite almost anatomical reduction; the objective and subjective scores were in most cases excellent. Modern everyday activities, such as keyboard typing, could be associated with the present

  5. Outcome of Boxer’s Fractures Treated by a Soft Wrap and Buddy Taping: A Prospective Study

    PubMed Central

    Kämpfen, Stephan; Berli, Martin; Fritschy, Daniel; Della Santa, Dominique; Fusetti, Cesare

    2007-01-01

    Introduction The ideal treatment for a boxer’s fracture remains controversial, particularly the degree of volar dislocation considered acceptable for nonoperative treatment. Patients and Methods From December 2003 to December 2004, 25 patients who sustained a subcapital metacarpal fracture of the little finger with volar angulation between 30 to 75° were prospectively enrolled in the study. All patients were treated with a circular self-adherent wrap covering metacarpal bones II–V and buddy taping of the ring and little fingers for a period of 3 weeks while allowing immediate free range of motion. Results Final evaluation at a mean of 5 months revealed all patients to be satisfied without subjective functional impairment. All fractures healed, and the angulation of the fracture remained unchanged, but moderate shortening was observed. Active flexion of the metacarpophalangeal (MCP) joint was significantly lower on the fracture side, but as the median degree of MCP flexion was the same, this statistical difference was without clinical relevance. There was no loss in grip strength. A subjective long-term evaluation was performed by phone; at a median of 3 years, a QuickDash score gave a median of 0 point. Conclusion Treating a boxer’s fracture with angulation of up to 75° by soft wrap and buddy taping resulted in satisfied patients and good clinical results. PMID:18780055

  6. The effect of HIV on early wound healing in open fractures treated with internal and external fixation.

    PubMed

    Aird, J; Noor, S; Lavy, C; Rollinson, P

    2011-05-01

    There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.

  7. Sauvé-Kapandji and reverse Sauvé-Kapandji procedures for treating chronic longitudinal radioulnar dissociation with capitellum fracture.

    PubMed

    Hernández-Cortés, Pedro; Gómez-Sánchez, Rafael; Pajares-López, Miguel; O'Valle-Ravassa, Francisco

    2014-01-01

    Almost all reported cases of longitudinal radioulnar dissociation have involved fracture of the radial head, rupture of the interosseous membrane, and disruption of the distal radioulnar joint, although unusual patterns of Essex-Lopresti injury have also been described. To our knowledge, this is the first report of a chronic Essex-Lopresti variant including fracture of the capitellum. A displaced capitellum fracture must alert to the possibility of longitudinal radioulnar dissociation, even without concomitant radial head fracture or symptoms at the forearm and ulnar wrist. Successful mid-term results can be achieved by treating malunion of humeral condyle and proximal migration of the radius with simultaneous Sauvé-Kapandji procedure at the wrist and reverse Sauvé-Kapandji at the elbow.

  8. Functional Outcomes, Morbidity, Mortality, and Fracture Healing in 58 Consecutive Patients with Geriatric Odontoid Fracture Treated with Cervical Collar or Posterior Fusion

    PubMed Central

    Molinari, William J.; Molinari, Robert W.; Khera, Oner A.; Gruhn, William L.

    2013-01-01

    Controversy exists as to the most effective management option for elderly patients with type II odontoid fractures. The purpose of this study is to evaluate outcomes associated with rigid cervical collar and posterior fusion surgery. Patients with ≥ 50% odontoid displacement were treated with posterior fusion surgery including C1–2 (PSF group, n = 25, average age = 80 years). Patients with < 50% odontoid displacement were treated with a rigid cervical collar for 12 weeks (collar group, n = 33, average age = 83 years). These inhomogeneous groups were followed for an average of 14 months. Fracture healing rates were higher in the operative group (28% versus 6%). Neck Disability Index scores were slightly lower in the nonoperative group (13 versus 18.3, p = 0.23). Analogue pain scores were also slightly lower in the nonoperative group (1.3 versus 1.9, p = 0.26). The mortality rate was 12.5% in the collar group and 20% in the operative group. Complications were higher in the operative group (24% versus 6%). Rates of type II odontoid facture healing and stability appear to be higher in geriatric patients treated with posterior fusion surgery. Fracture healing and stability did not correlate with improved outcomes with respect to levels of pain, function, and satisfaction. Mortality and complication rates are lower in those patients with lesser-displaced fractures who are treated with a cervical collar and early mobilization. PMID:24436848

  9. Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns

    PubMed Central

    Alkumru, Hasan Necdet; Akalin, Buket

    2016-01-01

    PURPOSE The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND METHODS Two glass fiber reinforced post systems in two different sizes and polyethylene fiber ribbon in two different thicknesses (n=10) were used. The specimens, restored with all-ceramic crowns, were subjected to a compressive load (in N) delivered at a 130-degree angle to the long axis until a fracture could be noted. The results were analyzed statistically with a One-Way ANOVA test (P<.05). RESULTS Statistically significant differences were observed between the mean fracture resistance values of Postec, Snowlight, and Kerr Connect thin specimens (P<.0095). The Postec results (395.70 N) were found to be significantly higher than the others. No statistical difference was observed among the thick specimens (P<.2657). The mean fracture resistance values of the Snowlight thick samples were found to be higher than those of the Snowlight thin samples. The specimens were always fractured around the cemento-enamel junction at the palatinal side. No post fracture was observed for the thin Snowlight and Kerr Connect specimens or for the thick Postec and Kerr Connect specimens. Among the common failure types of the specimens, the worst was observed to be the root fracture failure. The highest post dislodgement failure result (80%) was obtained from the thin Kerr Connect specimen. CONCLUSION In terms of optimizing fracture resistance, the fiber post size selection should be done according to the forces applied to the restored teeth. PMID:27141261

  10. Autologous Membrane Induced Chondrogenesis (AMIC) for the treatment of acetabular chondral defect

    PubMed Central

    Fontana, Andrea

    2016-01-01

    Summary Background Acetabular chondral defect are very frequently associated to FAI. Treatment options are still questionable. Methods Between 2008 and 2014, 201 patients over 583 have been arthroscopically treated with the AMIC procedure for grade III and/or IV acetabular chondral lesions. Patients age was between 18 and 50 years; acetabular chondral lesion size was between 2 and 4 cm2; radiological Tönnis degree of osteoarthritis was ≤ 2. Results The mean follow up of the entire group of 201 patients was 5 years (from 8 to 2). Significant improvement, as measured by the mHHS, was observed at 6 months in comparison to preoperative levels (80.3 ± 8.3) (p<0.001). Continuous improvement with respect to each previous evaluation time point was seen, reaching the highest improvement level at the three year follow-up (85.5 ± 7.2). The mean mHHS improvement recorded at the five year follow-up compared with preoperative scores was 39.1 ± 5.9. Conclusions AMIC is a valid procedure to repair medium-sized chondral defects on the acetabular side of the hip found during treatment of FAI and lead to long-term favourable outcomes. Level of evidence IV. PMID:28066742

  11. Acetabular augmentation induced by extracorporeal shock waves in rabbits.

    PubMed

    Saisu, Takashi; Kamegaya, Makoto; Wada, Yuichi; Takahashi, Kenji; Mitsuhashi, Shigeru; Moriya, Hideshige; Maier, Markus

    2005-05-01

    We conducted this animal study to demonstrate whether exposing the acetabulum in immature rabbits to extracorporeal shock waves induces bone formation in the acetabulum. Five thousand shock waves of 100 MPa each were directed, from outside, at the acetabular roof of eight immature rabbits. At each of two time points (4 and 8 weeks) after treatment, the pelvises of four rabbits were removed and evaluated morphologically. Woven bone formation was observed on the lateral margin of the acetabular roof at 4 weeks after treatment, and the breadth of the acetabular roof in the coronal plane was significantly increased. Eight weeks after treatment, the woven bone disappeared; the breadth of the acetabular roof, however, was significantly increased. These findings demonstrated that extracorporeal shock waves induced acetabular augmentation in rabbits. We conclude that extracorporeal shock waves, perhaps, could be applied clinically for the treatment of acetabular dysplasia.

  12. The importance of acetabular component position in total hip arthroplasty.

    PubMed

    Daines, Brian K; Dennis, Douglas A

    2012-11-01

    Correct acetabular cup position is critical to successful total hip replacement. Unfortunately, malposition of acetabular cups is common and leads to increased rates of dislocation, wear, and ion toxicity. Despite the popularity of Lewinnek's safe zone, the exact target of acetabular abduction and version remains elusive. Differences in functional pelvic position, surgical approach, and femoral anteversion affect the optimal cup position for individual patients. Surgeons need to be aware of pelvic position changes from the supine to lateral decubitus position.

  13. Meralgia Paresthetica and Femoral Acetabular Impingement: A Possible Association

    PubMed Central

    Ahmed, Aiesha

    2010-01-01

    Meralgia paresthetica consists of pain and dysesthesia in the anterolateral thigh. Etiology is divided into spontaneous and iatrogenic causes. To my knowledge this has never been attributed to femoral acetabular impingement. This case highlights the presence of lateral femoral cutaneous neuropathy in the setting of femoral acetabular impingement syndrome thus raising the possibility of an association. Keywords Femoral acetabular impingement; Lateral femoral cutaneous nerve; Dysesthesia; Nerve conduction studies PMID:22043261

  14. Syndrome of symptomatic adult acetabular dysplasia (SAAD syndrome)

    PubMed Central

    Birrell, F; Silman, A; Croft, P; Cooper, C; Hosie, G; Macfarlane, G

    2003-01-01

    Design: Cross sectional analysis of a prospective cohort. Setting: 35 general practices across the UK. Subjects: 195 patients (63 male, 132 female) aged 40 years and over presenting with a new episode of hip pain Results: The prevalence of acetabular dysplasia in this study of new presenters with hip pain was high (32%). There was no significant relationship between acetabular dysplasia and radiographic OA overall. Conclusions: The high prevalence of acetabular dysplasia across all grades of OA severity suggests that dysplasia itself may be an important cause of hip pain ("symptomatic adult acetabular dysplasia"). PMID:12634238

  15. Measurement of the "safe zone" and the "dangerous zone" for the screw placement on the quadrilateral surface in the treatment of pelvic and acetabular fractures with Stoppa approach by computational 3D technology.

    PubMed

    Zhang, Sheng; Su, Wanhan; Luo, Qiang; Leung, Frankie; Chen, Bin

    2014-01-01

    This study is aimed at definition of the safe and dangerous zone for screw placement with Stoppa approach for rapid identification during operation and a new way for the studies on the "safe zone." Pelvic CT data of 84 human subjects were recruited to reconstruct the three-dimensional (3D) models. The distances between the edges of the "safe zone," "dangerous zone," and specific anatomic landmarks such as the obturator canal and the pelvic brim were precisely measured, respectively. The results show that the absolute "dangerous zone" was from the pelvic brim to 3.07 cm below it and within 2.86 cm of the obturator canal, while the region 3.56 cm below the pelvic brim or 3.85 cm away from the obturator canal was the absolute "safe zone" for screw placement. The region between the absolute "safe zone" and the absolute "dangerous zone" was the relatively "dangerous zone." As a conclusion, application of computer-assisted 3D modeling techniques aids in the precise measurement of "safe zone" and "dangerous zone" in combination with Stoppa incision. It was not recommended to place screws on the absolute dangerous zone, while, for the relatively "dangerous zone," it depends on the individual variations in bony anatomy and the fracture type.

  16. Effect of Post Material and Length on Fracture Resistance of Endodontically Treated Premolars: An In-Vitro Study

    PubMed Central

    Amarnath, G S; Swetha, M U; Muddugangadhar, B C; Sonika, Radhika; Garg, Ashu; Rao, T R Poonam

    2015-01-01

    Background: Endodontically treated teeth with posts are more prone to fracture. Hence, the purpose of this study was to investigate the in-vitro fracture resistance of devitalized teeth and mode of failure restored with posts of different materials and different lengths. Materials and Methods: Sixty freshly extracted human mandibular premolars were endodontically treated and then restored with 1 of 2 prefabricated posts: Stainless-steel (SS) and glass-fiber (fiber posts [FP]) with intraradicular lengths of 4, 5 or 10 mm (n = 10). Following core restoration, a static compressive load was applied perpendicular to the long-axis of the teeth. Initial failure of each specimen was recorded in Newton. The mode of failure was also determined radiographically. The data were analyzed using two-way ANOVA and Tukey's post-hoc analysis with Bonferroni adjustment. Results: Analysis indicated significant differences (P < 0.001) among the groups. Among the SS posts, SS/7 (246 N) exhibited the highest failure load and SS/4 (122 N) the lowest. FP/10 (140.5 N) exhibited the highest failure load among the FP and FP/4 (68.5 N) the lowest. SS posts showed post pull out, followed by core fracture while FP showed core debonding, followed by core fracture as the primary mode of failure. Conclusion: Fracture resistance of the teeth proportionately increased with increase in the length of FP while it decreased with that of metal post. SS posts showed greater fracture resistance than FP when 90° load was applied. PMID:26229366

  17. Flexible intramedullary nails with traction versus plaster cast for treating femoral shaft fractures in children: comparative retrospective study.

    PubMed

    Nascimento, Fabiano Prata do; Santili, Cláudio; Akkari, Miguel; Waisberg, Gilberto; Braga, Susana dos Reis; Fucs, Patrícia Maria Moraes de Barros

    2013-01-01

    CONTEXT AND OBJECTIVE Femoral fractures are common in children between 2 and 12 years of age, and 75% of the lesions affect the femoral shaft. Traction followed by a plaster cast is universally accepted as conservative treatment. However, in some situations, a surgical approach is recommended. The objective here was to compare treatments for femoral shaft fractures using intramedullary nails (titanium elastic nails, TEN) versus traction and plaster casts in children. The hypothesis was that TEN might provide better treatment, with good clinical results in comparison with plaster casts. DESIGN AND SETTING This retrospective comparative study was conducted in a public university hospital. METHODS Sixty children with femoral fractures were evaluated; 30 of them underwent surgical treatment with TEN and 30 were treated conservatively using plaster casts. The patients' ages ranged from 5 to 13 years (mean of 9 years). RESULTS The mean duration of hospitalization was nine days for the surgical group and 20 days for the conservative group. The incidence of overgrowth in the patients treated with TEN was 60.0% and, for those treated conservatively, 13.3%. Partial weight-bearing was allowed after 3.5 weeks in the surgical group and after 9.6 weeks in the conservative group. New hospitalization was required for 90.0% in the surgical group and 16.7% in the conservative group. Patients treated with plaster casts presented higher incidence of complications, such as loss of reduction. CONCLUSIONS The surgical method presented better results for children.

  18. Micro-CT analysis with multiple thresholds allows detection of bone formation and resorption during ultrasound-treated fracture healing.

    PubMed

    Freeman, Theresa A; Patel, Payal; Parvizi, Javad; Antoci, Valentin; Shapiro, Irving M

    2009-05-01

    Multiple threshold algorithms applied to microcomputed tomography analysis were used to probe the effects of low-intensity pulsed ultrasound on fracture healing. Rat femurs were fractured in accordance with IACUC guidelines. Ultrasound treatment was administered daily to one femur; the contralateral bone was treated with a sham transducer. Each week for 3 weeks healing fractures were harvested and scanned by micro-CT. Remodeling activity was confirmed by evaluation of TRAP activity. Using thresholds of 331-700 and 225-330, area of cortical bone, and new bone formation, respectively, were identified, and by inference, regions of bone resorption. The increased sensitivity of this multithresholding procedure revealed that ultrasound treatment significantly increased the rate of fracture healing in vivo by activating both new bone formation and by increasing the removal of cortical bone in a time- and site-specific manner. At week 1, compared to the proximal side, there was a significant increase in new bone formation distal to the fracture site. Removal of the existing cortical bone followed the same pattern at week 2. Results of the study indicate that at sites of bone turnover, this multithresholding analytical technique can be used to provide quantitative information on bone formation, as well as resorption.

  19. The Influence of Composite Thickness with or without Fibers on Fracture Resistance of Direct Restorations in Endodontically Treated Teeth

    PubMed Central

    Torabzadeh, Hassan; Ghassemi, Amir; Sanei, Masoud; Razmavar, Sara; Sheikh-Al-Eslamian, Seyedeh Mahsa

    2014-01-01

    Introduction: This in vitro study evaluated the influence of composite thickness (with or without fiber reinforcement) on fracture resistance of direct restorations in endodontically treated teeth. Methods and Materials: Fifty-six intact human premolars were chosen and randomly divided into four groups (n=14). After preparation of a mesio-occluso-distal (MOD) cavities and cusp reduction, the teeth were endodontically treated. Subsequently, the samples were restored with composite resin using the following protocols: group 1; composite onlay with cusp coverage of 1.5 mm, group 2; composite onlay with cusp coverage of 2.5 mm, group 3; composite onlay (including resin-impregnated fiber) with cusp coverage of 1.5 mm and group 4; composite onlay (including resin-impregnated fiber) with cusp coverage of 2.5 mm. The fracture resistance of teeth in all test groups was calculated by subjecting them to a progressively increasing compressive axial force in the universal testing machine with the cross-head speed of 1 mm/min to the point of fracture. The data were analyzed using the Kruskal-Wallis test. Results: The mean fracture strengths and obtained standard error were 1263.85±74.03 N, 1330.26±128.01 N, 1344.92±64.40 N and 1312.54±75.63 N for groups 1 to 4, respectively. Statistical analysis revealed no significant difference between groups. Conclusion: Cusp coverage of 1.5 and 2.5 mm in MOD access cavities with or without insertion of resin impregnated fiber had similar fracture rates in the endodontically treated teeth. PMID:25031597

  20. Comparison of fracture resistance of endodontically treated teeth restored with nanohybrid, silorane, and fiber reinforced composite: An in vitro study

    PubMed Central

    Bilgi, Priyanka Shripad; Shah, Nimisha Chinmay; Patel, Parth Pinakinbhai; Vaid, Deepa S

    2016-01-01

    Background: The present study was undertaken to evaluate the most suitable restorative for badly mutilated endodontically treated teeth. Aims: To evaluate and compare the fracture resistance of endodontically treated premolars restored with conventional nanohybrid, silorane composite with glass fibers and newer fiber-reinforced composite in mesio-occluso-distal (MOD) cavities. Materials and Methods: Sixty extracted human maxillary premolars were selected. Fifteen intact teeth served as positive controls (Group 1). Endodontic therapy was done in the remaining 45 teeth. MOD cavities were prepared in all the teeth with standardized dimensions and were randomly divided into three groups (Group 2 - nanohybrid + glass fibers, Group 3 - silorane + glass fibers, and Group 4 – fiber-reinforced composite). Restorations were done for all groups. Fracture resistance was measured by Instron universal testing machine. Statistical Analysis Used: One-way anova test and Tukey's post hoc test. Results: Highest fracture resistance was shown by intact teeth group followed by fiber-reinforced composite, nanohybrid, and silorane, respectively. Statistically Significant difference was revealed by anova test (P < 0.0001) and Tukey's post hoc test (P < 0.0001). Conclusions: Among the experimental groups, fiber-reinforced composite showed the highest fracture resistance. Statistically significant difference was observed for all the groups. PMID:27563188

  1. Navigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty

    PubMed Central

    Yoon, Jung-Ro; Yu, Jung Jin; Seo, Hyo-Sung

    2014-01-01

    Purpose To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. Materials and Methods This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation and radiographic data to determine whether the acetabular cup was located within the safe zone or not. To evaluate the clinical outcomes, preoperative and last follow-up Harris hip scores were checked, and the occurrence of complications was evaluated. Results According to the navigation data, the mean inclination and anteversion were 38.5°±4.7°(range, 32°-50°) and 16.6°±4.0°(range, 8°-23°), respectively. According to the radiographic data the mean inclination and anteversion were 40.5°±4.6°(range, 32°-50°) and 19.4°±4.2°(range, 8°-25°), respectively. In both cases, all values were within the safe zone. Harris hip score was improved in all patients from preoperative 52.3±14.4 points (range, 29-87 points) to 88.0±9.0 points (range, 65-99 points) at the last follow-up. There was no dislocation or loosening of both cases. Conclusion Navigated acetabular cup fixation is a useful technique for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty because it prevents the malposition and related complications. PMID:27536573

  2. Bilateral femoral insuffiency fractures treated with inflatable intramedullary nails: a case report.

    PubMed

    Demiralp, Bahtiyar; Ilgan, Seyfettin; Ozgur Karacalioglu, A; Cicek, Engin Ilker; Yildrim, Duzgun; Erler, Kaan

    2007-09-01

    Stress fractures could be classified as fatigue fractures and insufficiency fractures (IF). Fatigue fractures occur when abnormal mechanical stress is applied to a normal bone, on the other hand insufficiency fractures occur when normal to moderate pressure is applied to a bone that has decreased resistance (Daffner and Pavlov in Am J Radiol 159:242-245, 1992). IF have been observed mainly in patients with postmenopausal osteoporosis, and are becoming more common with the increase of elderly population (Daffner and Pavlov in Am J Radiol 159:242-245, 1992). Other systemic and metabolic conditions that can result in osteopenia and IF include osteomalacia, hyperparathyroidism, hyperthyroidism, rheumatoid arthritis, fluoride treatment, diabetes mellitus, fibrous dysplasia, Paget's disease, irradiation and mechanical factors (Daffner and Pavlov in Am J Radiol 159:242-245, 1992; Soubrier et al. in Joint Bone Spine 70:209-218, 2003; Epps et al. in Am J Orthop 33:457-460, 2004; Austin and Chrissos in Orthopedics 28:795-797, 2005). In this case report, the authors present an osteoporotic woman who developed bilateral insufficiency fracture of the femoral shaft after longstanding steroid, thyroxine replacement and alendronate therapy due to partial empty sella syndrome and osteoporosis, resulting in the treatment of the fracture by inflatable intramedullary nailing.

  3. Epidemiology of mandibular fractures treated at Kaunas University of Medicine Hospital, Lithuania.

    PubMed

    Kubilius, Ricardas; Keizeris, Tadas

    2009-01-01

    Fractures of the mandible are one of the most common maxillofacial injuries. Because the pattern and incidence of mandibular fractures vary in different countries, there is a need to evaluate aspects of mandibular trauma in Lithuania's population. In this retrospective study hospital files of Oral and maxillofacial surgery unit of Kaunas University of Medicine Hospital were examined. The data that we collected included age, gender, hospitalization time, trauma mechanism, site of fracture, associated injuries, diagnostic and treatment methods. 87.1% of patients were male and they predominated in all age groups with a male to female ratio of 6.8:1. The highest incidence of mandibular fractures in male patients was in the 16-30 year age group and 31-45 year group for females. Interpersonal violence was the main cause of mandibular fractures, followed by falls and road traffic accidents. The incidence of falls in the <16 year age group was higher than expected. The angle was the most common fracture site (34.8%) and 51.7% patients experienced multiple fractures. The mean hospitalization time was 7.34+/-9.02 days. 55% of patients required Kirschner wire osteosynthesis, open reduction with miniplate osteosynthesis or a combination of both methods.

  4. Effect of Retained Austenite on the Fracture Toughness of Quenching and Partitioning (Q&P)-Treated Sheet Steels

    NASA Astrophysics Data System (ADS)

    Wu, Riming; Li, Wei; Zhou, Shu; Zhong, Yong; Wang, Li; Jin, Xuejun

    2014-04-01

    Fracture toughness K IC was measured by double edge-notched tension (DENT) specimens with fatigue precracks on quenching and partitioning (Q&P)-treated high-strength (ultimate tensile strength [UTS] superior to 1200 MPa) sheet steels consisting of 4 to 10 vol pct of retained austenite. Crack extension force, G IC, evaluated from the measured K IC, is used to analyze the role of retained austenite in different fracture behavior. Meanwhile, G IC is deduced by a constructed model based on energy absorption by martensite transformation (MT) behavior of retained austenite in Q&P-treated steels. The tendency of the change of two results is in good agreement. The Q&P-treated steel, quenched at 573 K (300 °C), then partitioned at 573 K (300 °C), holding for 60 seconds, has a fracture toughness of 74.1 MPa·m1/2, which is 32 pct higher than quenching and tempering steel (55.9 MPa·m1/2), and 16 pct higher than quenching and austempering (QAT) steel (63.8 MPa·m1/2). MT is found to occur preferentially at the tips of extension cracks on less stable retained austenite, which further improves the toughness of Q&P steels; on the contrary, the MT that occurs at more stable retained austenite has a detrimental effect on toughness.

  5. Radiological and Functional Outcome of Medial Epicondyle Fracture Treated Surgically in Children and Adolescents: A Retrospective Study

    PubMed Central

    Khatri, Kishor; Kharel, Krishna; Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2017-01-01

    Purpose: Fractures of the medial humeral epicondyle represent approximately 10% of all pediatric elbow fractures. Surgically treated pediatric fractures of the medial humeral epicondyle were analyzed retrospectively for their epidemiological, clinical, radiological and surgical parameters. The evaluation includes the Mayo elbow performance score (MEPS). Methods: Twenty-five surgically treated fractures of the medial humeral epicondyle were analyzed. A valgus stress test was performed under general anesthesia or sedation. All patients underwent open reduction internal fixation using a similar technique. The medial epicondylar fragment was anatomically reduced and fixed in all cases with screws and Kirschner wires. At final evaluation, union was assessed radiologically, and elbow function was assessed by MEPS. Results: An evaluation of all our patients after a mean follow-up of 8.75 months (SD=4.76) after initial surgery was possible. The mean age of patients at the time of injury was 10.8 years (SD=2.3). Fifteen (60%) dominant elbows were injured in our study and twelve (48%) elbows had an associated elbow dislocation. On examination in the operating room post anesthesia, all the elbow injuries revealed some degree of valgus instability. All our patients (n=25) showed good to excellent results in MEPS. Radiographically, union was achieved in all cases. Three patients developed postoperative ulnar nerve neuropraxia; all recovered at time of final follow-up. Conclusion: Our results suggest that open reduction internal fixation of displaced medial epicondyle fractures leads to satisfactory motion and function. A valgus stress test in the operating room can reveal the true nature of joint instability that can warrant operative stabilization of medial epicondylar injuries. PMID:28168131

  6. Fracture Strength of Endodontically Treated Teeth Restored with Casting Post and Core and Glass-Fiber with Composite Core

    PubMed Central

    Saatian, Sedigheh

    2006-01-01

    INTRODUCTION: Prefabricated metal and ceramic posts can be used with different kinds of core materials as an alternative to the conventional casting post and cores. It is unclear how these post and core systems can withstand different kind of forces in the mouth. The purpose of this study was to compare the fracture strength of endodontically treated, crowned maxillary incisors restored with casting post and cores and glass- fiber post with composite core and to evaluate their mode of fractures. MATERIALS AND METHODS: Thirty caries free, human maxillary central incisors with incisoapical length of 23 ± 1 mm were divided into two groups. After root canal treatment procedures and decronation of teeth 2mm above cementoenamel junction, Grope 1 was restored with glass- fiber posts and composite cores and group 2 received casting post and cores. Teeth were prepared with a circumferential shoulder including a 1-2 mm ferrule and 0.5 mm bevel; all posts were cemented with an adhesive resin and teeth were restored with complete coverage crowns. Loads were applied at an angle of 135 degrees using a universal testing machine. Compression force was applied until the specimens fractured. RESULTS: The median fracture strengths of groups 1 and 2 were 459 and 686 respectively (p<0.5). In group I, all fractures occurred in incisal third of roots. In groups II, 40% of fractures were in apical third and middle of roots. CONCLUSION: Within the limitation of this study, the results suggested that glass fiber with composite cores can be used as an alternative to cast posts and cores in anterior teeth when creating 2mm ferrule effect was possible in normal occlusion. Clinical trial is required to verify these in vitro results. PMID:24470803

  7. Low-temperature fracture toughness of a heat-treated mild steel

    SciTech Connect

    Chama, C.C.

    1995-02-01

    Specimens from a 0.14% C mild steel were austenitized at 1,000 C for 1 h and thereafter furnace-cooled or isothermally transformed at 700 C for 0.5, 2, and 8 h. The microconstituents present in the as-received material were ferrite and pearlite and their amounts did not substantially change even after heat treatment. The impact energy of the as-received and the furnace-cooled materials increased from 4 to 89 J and from 4 to 108 J, respectively, when the temperature was changed from {minus}196 to 23 C. For these materials, the failure mode was by ductile fracture at 0 and 23 C and by quasicleavage fracture at {minus}196 and {minus}40 C. The fracture toughness did not show any significant change with isothermal transformation time at 700 C. The failure mode of the isothermally transformed materials was always by quasicleavage fracture.

  8. Deformities in conservatively treated closed fractures of the shaft of the femur in children.

    PubMed

    Puttaswamaiah, Ravindra; Chandran, Prakash; Sen, Ramesh; Kataria, Sudha; Gill, Shivender Singh

    2006-04-01

    We present the outcome of non-operative management of fractures of the shaft of the femur in children. Thirty children with non-operatively managed unilateral fractures of the shaft of the femur were studied. The mean age was 6.5 years (range: 1.2 to 12). Axial, angular and rotational malunion were assessed clinically and radiologically by plain films and computed tomography (CT). All children had shortening of the fractured limb with a mean shortening of 1.8 cm (range: 0.5 to 3.5). A significant level of shortening was seen in children over 7 years. In the sagittal plane, all had anterior angulation ranging from 4 degrees to 31 degrees (mean: 17.8 degrees) and in the coronal plane, lateral angulation (varus) was seen in 90% (27 patients) with a mean angle of 8.9 degrees. Rotational malunion ranged from -43 degrees to +43 degrees (mean: 9.5 degrees), 30% had rotational malunion of > 20 degrees compared to the uninjured side; 73% had internal rotation malunion and 27% had external rotation malunion. We conclude that non-operative management of fractures of the shaft of the femur in children often results in malunion at the fracture, particularly in the older age group and in comminuted fractures. Perhaps a longer follow-up might have shown lower levels of malunion. Frequent monitoring of fracture position may reduce the occurrence of deformity. It may be appropriate to consider reduction and operative stabilisation of such fractures whenever neces-

  9. Arthroscopic excision of acetabular osteoid osteoma in a 7-year-old patient.

    PubMed

    Aşık, Mehmet; Erşen, Ali; Polat, Gökhan; Bilgili, Fuat; Tunalı, Onur

    2015-11-01

    The purpose of this study was to present the case report of a 7-year-old patient who was treated with hip arthroscopy for an acetabular osteoid osteoma. A 7-year-old patient was referred to our clinic with hip pain. In the assessment of the patient, an acetabular osteoid osteoma was detected in his right hip; it was adjacent to his triradiate cartilage. An arthroscopic surgery was planned as an alternative to open safe hip dislocation. The osteoid osteoma was completely removed with hip arthroscopy. Postoperative CT scanning and histopathological analysis confirmed the diagnosis. Exposure of the acetabulum can be problematic in paediatric patients due to the potential risks of open safe dislocation. Hip arthroscopy can safely be used for benign hip lesions in paediatric patients. Level of evidence Case report, Level V.

  10. Bone Repair on Fractures Treated with Osteosynthesis, ir Laser, Bone Graft and Guided Bone Regeneration: Histomorfometric Study

    NASA Astrophysics Data System (ADS)

    dos Santos Aciole, Jouber Mateus; dos Santos Aciole, Gilberth Tadeu; Soares, Luiz Guilherme Pinheiro; Barbosa, Artur Felipe Santos; Santos, Jean Nunes; Pinheiro, Antonio Luiz Barbosa

    2011-08-01

    The aim of this study was to evaluate, through the analysis of histomorfometric, the repair of complete tibial fracture in rabbits fixed with osteosynthesis, treated or not with infrared laser light (λ780 nm, 50 mW, CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical fractures were created, under general anesthesia (Ketamina 0,4 ml/Kg IP and Xilazina 0,2 ml/Kg IP), on the dorsum of 15 Oryctolagus rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with wire osteosynthesis. Animals of groups III and V were grafted with hydroxyapatite and GBR technique used. Animals of groups IV and V were irradiated at every other day during two weeks (16 J/cm2, 4×4 J/cm2). Observation time was that of 30 days. After animal death (overdose of general anesthetics) the specimes were routinely processed to wax and underwent histological analysis by light microscopy. The histomorfometric analysis showed an increased bone neoformation, increased collagen deposition, less reabsorption and inflammation when laser was associated to the HATCP. It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of CHA.

  11. An Effective Approach for Optimization of a Composite Intramedullary Nail for Treating Femoral Shaft Fractures.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2015-12-01

    The high stiffness of conventional intramedullary (IM) nails may result in stress shielding and subsequent bone loss following healing in long bone fractures. It can also delay union by reducing compressive loads at the fracture site, thereby inhibiting secondary bone healing. This paper introduces a new approach for the optimization of a fiber-reinforced composite nail made of carbon fiber (CF)/epoxy based on a combination of the classical laminate theory, beam theory, finite-element (FE) method, and bone remodeling model using irreversible thermodynamics. The optimization began by altering the composite stacking sequence and thickness to minimize axial stiffness, while maximizing torsional stiffness for a given range of bending stiffnesses. The selected candidates for the seven intervals of bending stiffness were then examined in an experimentally validated FE model to evaluate their mechanical performance in transverse and oblique femoral shaft fractures. It was found that the composite nail having an axial stiffness of 3.70 MN and bending and torsional stiffnesses of 70.3 and 70.9 N⋅m², respectively, showed an overall superiority compared to the other configurations. It increased compression at the fracture site by 344.9 N (31%) on average, while maintaining fracture stability through an average increase of only 0.6 mm (49%) in fracture shear movement in transverse and oblique fractures when compared to a conventional titanium-alloy nail. The long-term results obtained from the bone remodeling model suggest that the proposed composite IM nail reduces bone loss in the femoral shaft from 7.9% to 3.5% when compared to a conventional titanium-alloy nail. This study proposes a number of practical guidelines for the design of composite IM nails.

  12. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups.

    PubMed

    Smith, S L; Ash, H E; Unsworth, A

    2000-01-01

    A novel design of polyurethane compliant layer acetabular cup has been developed through a series of friction, creep and wear tests. Friction tests were initially conducted on ABG standard form, polyurethane acetabular cups and an ABG standard form, UHMWPE acetabular cup for comparison. The polyurethane cups showed lower friction than the UHMWPE cup with maximum friction factors between 0. 008 and 0.02 compared with 0.035 for the UHMWPE cup. This indicated that, in the polyurethane cups, more of the load across the joint was carried by the fluid entrapped in the joint space rather than with asperity contact, compared with the UHMWPE cup. The inherent compliance of the polyurethane is used to promote elasto-hydrodynamic lubrication. However, this compliance raised concerns over excessive creep, which may in turn adversely affect tribological performance. Therefore, creep tests were undertaken on the ABG standard form, polyurethane acetabular cups followed by further friction tests. Small amounts of creep occurred in the polyurethane cups at ambient temperature, which reduced the friction slightly (maximum friction factors of 0.009) due to increased conformity between the head and the cup. However, at 37 degrees C, greater creep occurred causing pinching of the femoral head by the acetabular cup resulting in lubricant starvation and higher friction (maximum friction factors of 0.035). The design of the polyurethane cups was subsequently modified to incorporate a flared rim to eliminate the possibility of fluid starvation through pinching. Creep in polyurethane acetabular cups is also affected by the method of fixation of the cups, due to the conformity with and the stiffness of the cup backing. Hence, a one-million-cycle wear test was performed on five ABG flared form, polyurethane acetabular cups on the Mk. I Durham Hip Joint Wear Simulator to evaluate the best method of fixation for the polyurethane cups. The smallest amount of penetration, due to creep and wear

  13. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    PubMed Central

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  14. Effect of novel restoration techniques on the fracture resistance of teeth treated endodontically: An in vitro study.

    PubMed

    Kemaloglu, Hande; Emin Kaval, Mehmet; Turkun, Murat; Micoogullari Kurt, Seniha

    2015-01-01

    The aim was to evaluate the effects of fiber-reinforced composite restorations and a bulk-fill resin composite on the fracture strength of mandibular premolars treated endodontically. Standard mesio-occluso-distal (MOD) cavities were prepared in 48 mandibular premolars. Following root canal treatment, teeth were assigned to four groups: Group 1, nano-hybrid resin composite; Group 2, polyethylene woven fiber plus nano-hybrid resin composite; Group 3, short fiber-reinforced resin composite plus nano-hybrid resin composite; and Group 4, bulk-fill resin composite plus nano-hybrid resin composite. Then, the teeth were subjected to the fracture toughness test. The data were analyzed statistically using one-way ANOVA, followed by Tukey's post-hoc test. The fiber-reinforced groups had better results than the nano-hybrid and bulk-fill composites (p<0.05), while the bulk-fill and nano-hybrid composite restorations gave similar results (p>0.05). Fiber-reinforcement improved the fracture strength of teeth with large MOD cavities treated endodontically. Bulk-fill composites can be used reliably as well as nano-hybrid composites.

  15. Fracture resistance of endodontically treated teeth restored with Zirconia filler containing composite core material and fiber posts

    PubMed Central

    Jeaidi, Zaid Al

    2016-01-01

    Objectives: To assess the fracture resistance of endodontically treated teeth with a novel Zirconia (Zr) nano-particle filler containing bulk fill resin composite. Methods: Forty-five freshly extracted maxillary central incisors were endodontically treated using conventional step back preparation and warm lateral condensation filling. Post space preparation was performed using drills compatible for fiber posts (Rely X Fiber Post) on all teeth (n=45), and posts were cemented using self etch resin cement (Rely X Unicem). Samples were equally divided into three groups (n=15) based on the type of core materials, ZirconCore (ZC) MulticCore Flow (MC) and Luxacore Dual (LC). All specimens were mounted in acrylic resin and loads were applied (Universal testing machine) at 130° to the long axis of teeth, at a crosshead speed of 0.5 mm/min until failure. The loads and the site at which the failures occurred were recorded. Data obtained was tabulated and analyzed using a statistical program. The means and standard deviations were compared using ANOVA and Multiple comparisons test. Results: The lowest and highest failure loads were shown by groups LC (18.741±3.02) and MC (25.16±3.30) respectively. Group LC (18.741±3.02) showed significantly lower failure loads compared to groups ZC (23.02±4.21) and MC (25.16±3.30) (p<0.01). However groups ZC (23.02±4.21) and MC (25.16±3.30) showed comparable failure loads (p=0.23). Conclusions: Fracture resistance of endodontically treated teeth restored with Zr filler containing bulk fill composite cores was comparable to teeth restored with conventional Zr free bulk fill composites. Zr filled bulk fill composites are recommended for restoration of endodontically treated teeth as they show comparable fracture resistance to conventional composite materials with less catastrophic failures. PMID:28083048

  16. [Subtrochanteric fracture in children treated with minimally invasive surgery: case report].

    PubMed

    Guzmán-Vargas, R; Rincón-Cardozo, D F; Camacho-Casas, J A

    2016-01-01

    Subtrochanteric fractures in children are rare events that occur in only 4% of all femur fractures; most injuries occur as a result of high-energy trauma, being young male patients the most affected. The management of this type of injury is controversial; there are many forms of treatment, including the use of plaster spica 90-90, closed reduction and use of elastic or rigid intramedullary nails, open reduction and plate placement, and the use of external fixators. Most suggest that for children under 10 a nonoperative approach should be preferred and that older ones should be managed surgically, but it is between six and 12-year-olds that most of the controversy exists. In this article, we present the management of this entity with a proximal fracture plate using a minimally invasive technique.

  17. Fracture Resistance of Endodontically Treated Roots Restored with Fiber Posts Using Different Resin Cements- An In-vitro Study

    PubMed Central

    Irodi, Sujatha; Mehta, Deepak; Subramanya, Shankar; Govindaraju, Vinay Kumar

    2017-01-01

    Introduction The influence of the remaining coronal tooth structure along with intra-radicular esthetic posts increases fracture resistance of fractured teeth especially in the anterior region. The advent of resin based luting cements improves the adhesion of fiber posts. Aim To evaluate the fracture resistance of endodontically treated roots restored with fiber posts using different resin cements – Calibra (etch and rinse), PermaFlo® DC (self-etch primer) and SmartCem2 (self-adhesive). Materials and Methods Extracted human maxillary central incisors having similar dimensions were decoronated at the Cemento-Enamel Junction (CEJ) to create 16mm long specimens and endodontically treated. A total of 45 teeth were divided into three groups with 15 teeth each for cementation of easy fiber posts (size1, 0.8mm diameter). Post spaces were prepared to a depth of 10mm. Group 1 – Caulk 34% phosphoric acid gel, dual cure adhesive Prime and Bond NT followed by luting of post with Calibra cement. Group 2 – Ultra – etch then Primer A and Primer B, and PermaFlo® DC was used to cement the post. Group 3 – SmartCem2 [1:1 ratio] was used to cement the post. The excess lengths of posts were seared and teeth were mounted on acrylic blocks and loaded under compressive force to the long axis of the tooth which increased in periodic pattern of 1mm/min. The value of the force at which each root section gets fractured was noted. The data were statistically analysed using ANOVA and Tukey’s Test. Results The mean fracture load (and SD) were as follows Group 1 – 762.400 (251.490); Group 2 – 662.933 (206.709); Group 3 – 657.800 (57.372). No statistically significant differences were seen among all three Groups, p-value (0.228). Conclusion Posts cemented using self -adhesive resin cement SmartCem2 have highest fracture resistance and bonding efficacy of self-adhesive technique showed reliably better results but was comparable to total–etch and self–etch techniques. PMID

  18. Canted seating of the Stryker Modular Dual Mobility liner within a Trident hemispherical acetabular shell.

    PubMed

    Eskildsen, Scott M; Olsson, Erik C; Del Gaizo, Daniel J

    2016-03-01

    A 75-year-old woman who suffered a left femoral neck fracture underwent a left total hip arthroplasty using a Stryker Trident (Kalamazoo, MI) hemispherical acetabular shell and Modular Dual Mobility (MDM) metal liner. Post-operative radiographs demonstrated canted seating of the liner. The patient was taken immediately back to the operating room where the acetabular liner appeared well seated superiorly but was in a canted position inferiorly. Removal and replacement was performed and post-operative radiographs demonstrated complete seating. Subsequent follow up at 6 months demonstrated good clinical function with no adverse radiographic findings. Canted seating is a potential complication of the MDM metal liner. Providers should be aware of potential incomplete seating inferiorly despite the superior portion of the liner being well seated.

  19. The use of a constrained cementless acetabular component for instability in total hip replacement.

    PubMed

    Rady, Ahmad Emad; Asal, Mohammed Kamal; Bassiony, Ayman Abdelaziz

    2010-01-01

    Recurrent dislocation after total hip arthroplasty is a disabling complication that can be difficult to treat. We evaluated the early clinical and radiographic outcome associated with the use of a constrained acetabular component for instability in total hip arthroplasty. Fifteen patients underwent either primary or revision total hip arthroplasty with a cementless constrained acetabular component for different indications. The mean patient age at surgery was 57.4 years and the mean clinical and radiological follow-up period was 26.4 months. Clinical assessment was performed by the Harris hip score and at the latest follow up patients reported outcome using the Oxford hip score questionnaire. All radiographs were evaluated for evidence of loosening. Only one patient experienced redislocation with the constrained prosthesis. The average Harris hip score increased from a preoperative mean of 22 (range, 16 - 36) to a postoperative mean of 85 (range, 66-94). Preoperatively, the mean Oxford Hip Score was 48.6, which decreased to 20.5 at the final examination. All but one of the 15 hips had a well-fixed, stable cup. Femoral component stability with bone ingrowth was achieved in 10 cases. A constrained acetabular component is an effective option for the treatment of hip instability in primary and revision arthroplasty in those at high risk of dislocation. The potential for aseptic loosening requires evaluation by long term studies.

  20. Accurate determination of screw position in treating fifth metatarsal base fractures to shorten radiation exposure time

    PubMed Central

    Wang, Xu; Zhang, Chao; Wang, Chen; Huang, Jia Zhang; Ma, Xin

    2016-01-01

    INTRODUCTION Anatomical markers can help to guide lag screw placement during surgery for internal fixation of fifth metatarsal base fractures. This study aimed to identify the optimal anatomical markers and thus reduce radiation exposure. METHODS A total of 50 patients in Huashan Hospital, Shanghai, China, who underwent oblique foot radiography in the lateral position were randomly selected. The angles between the fifth metatarsal axis and cuboid articular surface were measured to determine the optimal lag screw placement relative to anatomical markers. RESULTS The line connecting the styloid process of the fifth metatarsal base with the second metatarsophalangeal (MTP) joint intersected with the fifth metatarsal base fracture line at an angle of 86.85° ± 5.44°. The line connecting the fifth metatarsal base styloid with the third and fourth MTP joints intersected with the fracture line at angles of 93.28° ± 5.24° and 100.95° ± 5.00°, respectively. The proximal articular surface of the fifth metatarsal base intersected with the line connecting the styloid process of the fifth metatarsal base with the second, third and fourth MTP joints at angles of 24.02° ± 4.77°, 30.79° ± 4.53° and 38.08° ± 4.54°, respectively. CONCLUSION The fifth metatarsal base styloid and third MTP joint can be used as anatomical markers for lag screw placement in fractures involving the fifth tarsometatarsal joint. The connection line, which is normally perpendicular to the fracture line, provides sufficient mechanical stability to facilitate accurate screw placement. The use of these anatomical markers could help to reduce unnecessary radiation exposure for patients and medical staff. PMID:26767892

  1. Single-incision approach improves wound healing and bone union for treating mid-to-lower segment of tibiofibular fracture.

    PubMed

    Zhang, Yongguang; Zhuang, Yuehong; Wang, Benhai; Xu, Hao; Chen, Jinshui; Lin, Songqing

    2015-01-01

    The mid-to-lower segment of tibiofibular fractures (MLTFs) is commonly encountered in clinical practice, which is conventionally treated by the double-incision surgical approach. However, the double-incision approach frequently makes the closure of the wound extremely difficult and sometimes results in necrosis of skin around fractured sites. In the present study, our experience of using a single-incision surgical approach for treating MLTF was exhibited. From February 2005 to December 2013, the clinical outcomes of 212 patients with MLTFs who underwent either double-incision approach or single-incision approach were retrospectively evaluated and compared. Both groups were similar with respect to injury mechanism and all patients were followed up with the efficacies of treatment evaluated by Johner-Wruth criteria. The results demonstrated that the effective rate and the rate of excellent and good efficacy in the single-incision group were significantly higher than those in the double-incision group (P<0.05). In addition, the rates of skin wound healing and bone union after surgery in the single-incision group were significantly higher than those in the double-incision group (P<0.05). These findings indicate that the single-incision surgical approach, which holds the advantages of being milder in trauma, fewer in complications and better in function restoration, might be used as an alternative method for treating MLTFs.

  2. Fracture Resistance of Endodontically Treated Maxillary Premolars Restored by Various Direct Filling Materials: An In Vitro Study

    PubMed Central

    Mincik, Jozef; Timkova, Silvia; Urban, Renata

    2016-01-01

    The aim of this study is to compare the effect of various restorative materials on fracture resistance in maxillary premolars. Premolars (n = 64) with no restorations or cracks were selected. MOD cavities were prepared considering the buccolingual width to be equal to half of the intercuspal distance. The specimens were randomly divided into 8 groups, 8 specimens each: group A intact teeth, group B unfilled cavity, group C composite made by oblique layering technique, group D composite with 2 mm cusp coverage, group E bulk-filled posterior composite, group F glass-ionomer, group G amalgam, and group H composite with proximal boxes. The specimens were subjected to an axial compression load with the mean values of fracture resistance in group A: 1289 N, group B: 181.75 N, group C: 445.38 N, group D: 645.88 N, group E: 355.13 N, group F: 352.00 N, group G: 191.38 N, and group H: 572.00 N. There was no significant difference between groups B and G, between C and D, E, and F, and between group D and H. All other measurements were statistically significant. We conclude that composite restoration with cusp coverage is the most ideal nonprosthetic solution for endodontically treated teeth. Cusp coverage increases the fracture resistance compared to the conventional cavity design. PMID:27656212

  3. Pathological fracture after migration of cement used to treat distal femur physeal arrest.

    PubMed

    Shea, Kevin G; Rab, George T; Dufurrena, Magen

    2009-07-01

    Treatment of physeal arrest with bar removal and placement of interposition materials in young patients has been shown to restore physeal growth. Among the various materials that have been used to prevent early reformation of the physeal bar (fat, silastic, cartilage), Peterson recommended the use of Cranioplast, as this material can prevent bar reformation, and it is radiolucent because it does not contain barium. Peterson suggested steps be taken to prevent migration of the Cranioplast, as migration of the interposition material might allow for reformation of the physeal bar. Although Peterson had not observed cement migration leading to pathologic fracture, he felt that this was a potential concern. We describe the case of cement migration from the epiphysis into the diaphysis, leading to a pathological femur fracture. Despite migration of the Cranioplast, the physeal bridge did not reform, and the patient had nearly normal growth 7 years after the initial physeal arrest procedure.

  4. Bone fractures among postmenopausal patients with endocrine-responsive early breast cancer treated with 5 years of letrozole or tamoxifen in the BIG 1-98 trial

    PubMed Central

    Rabaglio, M.; Sun, Z.; Castiglione-Gertsch, M.; Hawle, H.; Thürlimann, B.; Mouridsen, H.; Campone, M.; Forbes, J. F.; Paridaens, R. J.; Colleoni, M.; Pienkowski, T.; Nogaret, J.-M.; Láng, I.; Smith, I.; Gelber, R. D.; Goldhirsch, A.; Coates, A. S.

    2009-01-01

    Background: To compare the incidence and timing of bone fractures in postmenopausal women treated with 5 years of adjuvant tamoxifen or letrozole for endocrine-responsive early breast cancer in the Breast International Group (BIG) 1-98 trial. Methods: We evaluated 4895 patients allocated to 5 years of letrozole or tamoxifen in the BIG 1-98 trial who received at least some study medication (median follow-up 60.3 months). Bone fracture information (grade, cause, site) was collected every 6 months during trial treatment. Results: The incidence of bone fractures was higher among patients treated with letrozole [228 of 2448 women (9.3%)] versus tamoxifen [160 of 2447 women (6.5%)]. The wrist was the most common site of fracture in both treatment groups. Statistically significant risk factors for bone fractures during treatment included age, smoking history, osteoporosis at baseline, previous bone fracture, and previous hormone replacement therapy. Conclusions: Consistent with other trials comparing aromatase inhibitors to tamoxifen, letrozole was associated with an increase in bone fractures. Benefits of superior disease control associated with letrozole and lower incidence of fracture with tamoxifen should be considered with the risk profile for individual patients. PMID:19474112

  5. Management and Followup of Complicated Crown Fractures in Young Patients Treated with Partial Pulpotomy

    PubMed Central

    Ojeda-Gutierrez, Francisco; Martinez-Marquez, Brenda; Arteaga-Larios, Soraya; Ruiz-Rodriguez, M. Socorro; Pozos-Guillen, Amaury

    2013-01-01

    Two cases of young patients with traumatized permanent teeth having complicated crown fractures are reported. Endodontic management included partial pulpotomy by the Cvek technique; restorative management included resin restoration and reattachment of the teeth fragments. Treatments were considered successful in all cases according to the following criteria: absence of clinical symptoms, absence of X-ray signs of pathology, and presence of pulpal vitality 6 to 25 months after treatment. PMID:23864963

  6. Influence of polymerisation method and type of fibre on fracture strength of endodontically treated teeth.

    PubMed

    Tekçe, Neslihan; Pala, Kansad; Tuncer, Safa; Demirci, Mustafa; Serim, Merve Efe

    2016-11-25

    The aim of this study was to investigate (i) the effect of direct or indirect polymerisation of adhesive-impregnated ribbon fibre under 4-mm bulk-filled composites on fracture strength; (ii) to compare polyethylene ribbon fibre-reinforcement composites with short fibre-reinforced composite; and (iii) the effectiveness of polyethylene ribbon fibre according to the restorative materials used (low-viscous bulk-fill composite, high-viscous flowable composite or conventional paste composite). Seventy molars were divided into seven groups; (groups 1-2) Ribbond-reinforced Surefil-SDR; (group 3) Ribbond-reinforced G Aenial Flo; (group 4) Ribbond-reinforced G Aenial Posterior; (group 5) short fibre-reinforced composite everX Posterior; (group 6) unfilled cavity; (group 7) intact teeth. Ribbond was adopted to cavity walls by impregnating an adhesive and using a flowable composite. In group 1, adhesive-impregnated Ribbond was polymerised directly using a light-curing-unit, and indirectly in group 2 under 4-mm bulk-filled composite. Direct or indirect polymerisation of adhesive impregnated ribbon fibre under 4-mm bulk-filled composite did not change the fracture strength results. Polyethylene ribbon fibre-reinforced groups (groups 1-4) and short fibre-reinforced composite group (group 5) displayed similar results. Polyethylene ribbon fibre can be used safely under 4-mm bulk-filled composites. Ribbond-reinforced low-viscous bulk-fill, high-viscous flowable, and conventional paste composite exhibited similar fracture strength results.

  7. In Hospital and 3-Month Mortality and Functional Recovery Rate in Patients Treated for Hip Fracture by a Multidisciplinary Team

    PubMed Central

    Rostagno, Carlo; Buzzi, Roberto; Campanacci, Domenico; Boccacini, Alberto; Cartei, Alessandro; Virgili, Gianni; Belardinelli, Andrea; Matarrese, Daniela; Ungar, Andrea; Rafanelli, Martina; Gusinu, Roberto; Marchionni, Niccolò

    2016-01-01

    Objectives Medical comorbidities affect outcome in elderly patients with hip fracture. This study was designed to preliminarily evaluate the usefulness of a hip-fracture unit led by an internal medicine specialist. Methods In-hospital and 3-month outcomes in patients with hip fracture were prospectively evaluated in 121 consecutive patients assessed before and followed after surgery by a multidisciplinary team led by internal medicine specialist; 337 consecutive patients were recalled from ICD-9 discharge records and considered for comparison regarding in-hospital mortality. Results In the intervention period, patients treated within 48 hours were 54% vs. 26% in the historical cohort (P<0.0001). In-hospital mortality remained stable at about 2.3 per 1000 person-days. At 3 months, 10.3% of discharged patients had died, though less than 8% of patients developed postoperative complications (mainly pneumonia and respiratory failure). The presence of more than 2 major comorbidities and the loss of 3 or more BADL were independent predictors of death. 50/105 patients recovered previous functional capacity, but no independent predictor of functional recovery could be identified. Mean length of hospital stay significantly decreased in comparison to the historical cohort (13.6± 4.7 vs 17 ± 5 days, p = 0.0001). Combined end-point of mortality and length of hospitalization < 12 days was significantly lower in study period (27 vs 34%, p <0.0132). Conclusions Identification and stabilization of concomitant clinical problems by internal medicine specialists may safely decrease time to surgery in frail subjects with hip fracture. Moreover, integrated perioperative clinical management may shorten hospital stay with no apparent increase in in-hospital mortality and ultimately improve the outcome. These results are to be confirmed by a larger study presently ongoing at our institution. PMID:27389193

  8. Anterior pre-tensioned external fixator for pelvic fractures and dislocations. Initial clinical series.

    PubMed

    Queipo-de-Llano, A; Lombardo-Torre, M; Leiva-Gea, A; Delgado-Rufino, F B; Luna-González, F

    2016-12-01

    In the treatment of unstable pelvic ring fractures, external fixators have the limitation of not adequately stabilizing the injured posterior elements. This article presents a novel and simple technique of temporary external fixation of the pelvic ring, able to produce compression of both the anterior and posterior pelvic elements. A curved flexible carbon-fiber rod is used, pre-tensioned before attachment to supra-acetabular Schanz screws. Although more extensive clinical experience is required, favorable preliminary results in a series of 13 patients with unstable pelvic fracture were encouraging: the aim of closing the posterior and anterior elements of the pelvic ring was achieved in all cases treated with this technique, and 12 patients survived. Radiological results were excellent in 3 cases and good in 9 cases. No major complications, such as secondary displacement, vertical re-displacement or deep infection, were observed. Mean operative time was 25min, compatible with emergency management.

  9. [Atlas fractures].

    PubMed

    Schären, S; Jeanneret, B

    1999-05-01

    Fractures of the atlas account for 1-2% of all vertebral fractures. We divide atlas fractures into 5 groups: isolated fractures of the anterior arch of the atlas, isolated fractures of the posterior arch, combined fractures of the anterior and posterior arch (so-called Jefferson fractures), isolated fractures of the lateral mass and fractures of the transverse process. Isolated fractures of the anterior or posterior arch are benign and are treated conservatively with a soft collar until the neck pain has disappeared. Jefferson fractures are divided into stable and unstable fracture depending on the integrity of the transverse ligament. Stable Jefferson fractures are treated conservatively with good outcome while unstable Jefferson fractures are probably best treated operatively with a posterior atlanto-axial or occipito-axial stabilization and fusion. The authors preferred treatment modality is the immediate open reduction of the dislocated lateral masses combined with a stabilization in the reduced position using a transarticular screw fixation C1/C2 according to Magerl. This has the advantage of saving the atlanto-occipital joints and offering an immediate stability which makes immobilization in an halo or Minerva cast superfluous. In late instabilities C1/2 with incongruency of the lateral masses occurring after primary conservative treatment, an occipito-cervical fusion is indicated. Isolated fractures of the lateral masses are very rare and may, if the lateral mass is totally destroyed, be a reason for an occipito-cervical fusion. Fractures of the transverse processes may be the cause for a thrombosis of the vertebral artery. No treatment is necessary for the fracture itself.

  10. Residual stress and damage-induced critical fracture on CO2 laser treated fused silica

    SciTech Connect

    Matthews, M; Stolken, J; Vignes, R; Norton, M

    2009-11-02

    Localized damage repair and polishing of silica-based optics using mid- and far-IR CO{sub 2} lasers has been shown to be an effective method for increasing optical damage threshold in the UV. However, it is known that CO{sub 2} laser heating of silicate surfaces can lead to a level of residual stress capable of causing critical fracture either during or after laser treatment. Sufficient control of the surface temperature as a function of time and position is therefore required to limit this residual stress to an acceptable level to avoid critical fracture. In this work they present the results of 351 nm, 3 ns Gaussian damage growth experiments within regions of varying residual stress caused by prior CO{sub 2} laser exposures. Thermally stressed regions were non-destructively characterized using polarimetry and confocal Raman microscopy to measure the stress induced birefringence and fictive temperature respectively. For 1 {approx} 40s square pulse CO{sub 2} laser exposures created over 0.5-1.25 kW/cm{sup 2} with a 1-3 mm 1/e{sup 2} diameter beam (T{sub max} {approx} 1500-3000 K), the critical damage site size leading to fracture increases weakly with peak temperature, but shows a stronger dependence on cooling rate, as predicted by finite element hydrodynamics simulations. Confocal micro-Raman was used to probe structural changes to the glass over different thermal histories and indicated a maximum fictive temperature of 1900K for T{sub max} {ge} 2000 K. The effect of cooling rate on fictive temperature caused by CO{sub 2} laser heating are consistent with finite element calculations based on a Tool-Narayanaswamy relaxation model.

  11. Trabecular metal cup without augments for acetabular revision in case of extensive bone loss and low bone-prosthesis contact.

    PubMed

    Pierannunzii, L; Mambretti, A; D'Imporzano, M

    2011-01-01

    Current evidences in revision hip arthroplasty suggest to treat severe acetabular bone loss with dedicated implants, such as anti-protrusio cages, stemmed cups, modular systems supplied with iliac flanges and obturatory hook. However recent literature is reporting satisfactory outcomes with simple elliptical Trabecular Metal cups. Purpose of the study was to evaluate mid-term results of such a surgical procedure. All hip revisions performed from 2008 to 2009 with implantation of a TMT multi-hole acetabular cup without augmentations were retrospectively reviewed. The cases with low-degree acetabular bone loss (stage I and II according to GIR classification), with surgical report poorly describing the bone defect, with inadequate pre- and post-operative x-rays were ruled out. Twenty-five cases were identified, but four were lost to follow-up. The twenty-one patients were 71 year-old on average (from 60 to 82), with stage IV bone loss in 6 cases and stage III bone loss in 15 cases. Mean interval from surgery to evaluation was 20.9 months (from 13 to 30). The evaluation included bone-prosthesis contact estimation, component position, survivorship, complications, final Harris Hip Score, presence of periprosthetic radiolucencies. Host bone-prosthesis contact was estimated to be about 35%. Only three implant were subsequently reoperated (for infection, early migration, recurrent dislocation). The HHS among non-reoperated 18 patients was 81.96 on average (from 63.44 to 95.82). Six cases showed thin radiolucencies in one of the three Charnley zones, while three cases showed radiolucencies in two. None of these images was evolutive, thus they were not considered signs of loosening. The mid-term results of this series confirm the hypothesis that a porous tantalum acetabular cup is an effective option to deal with difficult acetabular revisions. Although no extra-acetabular fixation device is available, the very high surface friction guaranteed by the material and the

  12. The use of a "rim cutter" device and a flanged cup for improving the mantle of the acetabular component of a cemented Exeter total hip arthroplasty.

    PubMed

    Fernández-Valencia, Jenaro Ángel; Gallart, Xavier; Bori, Guillem; Rodríguez-Roiz, Juan Miguel; Combalia, Andreu

    2016-12-01

    A retrospective study was performed to evaluate the cement mantle in two groups of patients treated with the acetabular components of cemented Exeter total hip arthroplasties (THAs). Two groups of 20 patients were compared: Group 1 received non-flanged acetabular cemented cups (Contemporary, Stryker) and Group 2 received flanged acetabular cemented cups (X3 Rim Fit, Stryker). Cups in Group 2 were implanted after using a rim cutter device. Group 2 showed better penetration of cement in zone 1 (10.76 mm compared with 2.93 mm; p = 0.008) and a thicker cement mantle in zone 1 (3.57 mm compared with 2.89 mm; p = 0.04). More cups in Group 2 had a cement mantle thickness less than 3 mm (30 % in Group 1 compared with 70 % in Group 2; p = 0.0039). No other radiological differences were observed. These results favor the use of a rim cutter device and flanged cup to improve the cement mantle for the acetabular components of cemented Exeter THAs. However, the improvements were less than expected. In view of the results of previous studies, further research is therefore needed to assess the value of this approach in improving the acetabular cement mantle.

  13. Wear of highly crosslinked polyethylene acetabular components

    PubMed Central

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Munn, Zachary; Howie, Donald W

    2015-01-01

    Background and purpose Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). Methods A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). Results 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2–10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. Interpretation This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear. PMID:25301435

  14. Cementation of an acetabular liner into a well-fixed acetabular shell during revision total hip arthroplasty.

    PubMed

    Springer, Bryan D; Hanssen, Arlen D; Lewallen, David G

    2003-10-01

    Cementing a polyethylene liner into a well-fixed acetabular shell during revision hip arthroplasty may be appropriate in select patients. The purpose of this study was to review our early results with this technique. Sixteen patients with >2-year follow-up or who had any complications at <2 years from surgery were identified. Indications for this technique included: failure of the previous locking mechanism, significant polyethylene wear, malposition of the well-fixed metal shell, and previous removal of the liner with a retained acetabular shell. One acetabular shell has been revised at 13 months for multiple dislocations. Hip scores improved an average of 24.2 points. Radiographs revealed no polyethylene dissociation or acetabular loosening. Complications occurred in 7 patients. Initial results appear successful at providing secure fixation, while preventing the bone loss that might occur with removal of a well-fixed component.

  15. The outcome and parents-based cosmetic satisfaction following fixation of paediatric supracondylar humerus fractures treated by closed method with or without small medial incision.

    PubMed

    Basaran, Serdar Hakan; Ercin, Ersin; Bayrak, Alkan; Bilgili, Mustafa Gokhan; Kizilkaya, Cemal; Dasar, Uygar; Avkan, Mustafa Cevdet

    2016-01-01

    Supracondylar humerus fractures are common in children. Displaced fractures are usually treated with closed reduction and cross pin fixation. But, medial pinning may cause the ulnar nerve injury. The aim of this study was to compare the parents-based cosmetic satisfaction of the incision scars in children with displaced supracondylar humerus fractures treated by closed reduction and cross pin fixation with or without small medial incision. We retrospectively reviewed the medical records of 72 children with displaced supracondylar humerus fractures treated two different closed reduction and percutaneous pinning methods at our institution from January 2010 through December 2013. A group has 36 patients treated with small medial incision and crossed K-wires fixation after closed reduction. The other group has 36 patients treated with closed reduction and K-wires fixation. At the final follow-up, the patients were evaluated radiologically and clinically with Flynn's criteria. Furthermore, a visual analogue scale was used to determine of the parents-based cosmetic satisfaction score. All fractures healed without major complications at the final clinical and radiological assessment. Although, between the two groups did not differ in terms of Flynn cosmetic and functional outcomes, there were statistically significant differences between both groups according to the parents-based cosmetic satisfaction scores. The closed reduction and crossed pin fixation without small medial incision should be preferred first because of better the parents-based cosmetic satisfaction.

  16. A comparison of the fracture resistances of endodontically treated mandibular premolars restored with endocrowns and glass fiber post-core retained conventional crowns

    PubMed Central

    Guo, Jing; Wang, Zhiming; Li, Xuesheng; Sun, Chaoyang; Gao, Erdong

    2016-01-01

    PURPOSE This in-vitro study aimed to evaluate the fracture resistances and failure modes of endodontically treated mandibular premolars restored with endocrowns and conventional post-core retained crowns. MATERIALS AND METHODS Thirty mandibular premolars were assigned into three groups (n=10): GI, intact teeth; GE, teeth with endocrowns; GC, teeth with conventional post-core supported crowns. Except for the teeth in group GI, all specimens were cut to 1.5 mm above the cementoenamel junction and endodontically treated. Both endocrowns and conventional crowns were fabricated from lithium-disilicate blocks using a CEREC 3D CAD/CAM unit. All specimens were subjected to thermocycling and then to 45° oblique compressive load until fracture occurred. The fracture resistance and failure mode of each specimen were recorded. Data were analyzed with one-way ANOVA and LSD Post Hoc Test (α=.05). RESULTS The fracture resistances of GE and GC were significantly lower than that of GI (P<.01), while no significant difference was found between GE and GC (P=.702). As of the failure mode, most of the specimens in GE and GC were unfavorable while a higher occurrence of favorable failure mode was presented in GI. CONCLUSION For the restoration of mandibular premolar, endocrown shows no advantage in fracture resistance when compared with the conventional method. Both of the two methods cannot rehabilitate endodontically treated teeth with the same fracture resistances that intact mandibular premolars have. PMID:28018567

  17. Computed modeling of humeral mid-shaft fracture treated by bundle nailing.

    PubMed

    Obruba, Petr; Capek, Lukas; Henys, Petr; Kopp, Lubomir

    2016-10-01

    Elastic bundle nailing is a method for simple humeral mid-shaft fracture osteosynthesis. The aim of our subsequent numerical simulations was to find out torsional and bending stiffness of an elastic bundle nailed humerus. Parametrical 3D numerical model was developed. The diameter of nails was the varying parameter of 1.8, 2.5, 3 and 4 mm. From our results can be seen that the bending stiffness in bundle nailing technique does not depend on nail diameter. On the contrary the torsional stiffness does highly depend on nail diameter. The dependency of the maximal stress on a nail diameter during bending and torsion of the humerus is non-linear. It can be seen that the higher diameter is used the higher stress occurs. Achieved results allow us for the recommendation of optimal nail diameter for this method, which lies between 2 and 3 mm.

  18. Fatigue failure in the cement mantle of a simplified acetabular replacement model

    PubMed Central

    Zant, Nikolaus P.; Wong, Charles K.Y.; Tong, Jie

    2007-01-01

    Although the role of fatigue failure in aseptic loosening of cemented total hip replacements has been extensively studied in femoral components, studies of fatigue failure in cement mantle of acetabular replacements have yet to be reported, despite that the long-term failure rate in the latter is about three times that of femoral components. Part of the reason may be that a complex pelvic bone structure does not land itself readily for a 2D representation as that of a femur. In this work, a simple multilayer model has been developed to reproduce the stress distributions in the cement mantle of an acetabular replacement from a plane strain finite element pelvic bone model. The experimental multilayer model was subjected to cyclic loading up to peak hip contact force during normal walking. Radial fatigue cracks were observed in the vicinity of the maximum tangential and compressive stresses, as predicted by the FE models. Typical fatigue striations were also observed on the fracture surfaces post cyclic testing. The results were examined in the context of retrieval studies, 3D FE analysis and in vitro experimental results using full-sized hemi-pelvic bone models. PMID:19330048

  19. Closed reduction using the percutaneous leverage technique and internal fixation with K-wires to treat angulated radial neck fractures in children-case report.

    PubMed

    Jiang, Hai; Wu, Yongtao; Dang, Youting; Qiu, Yusheng

    2017-01-01

    Pediatric radial neck fractures are uncommon. Severely displaced and angulated fractures usually require treatment. Our goals for treatment are to avoid incision, reduce the fracture adequately with no reduction loss, and achieve good postoperative function. We aimed to observe the clinical outcomes of closed reduction with the percutaneous leverage technique and internal fixation with Kirschner-wires (K-wires) to treat angulated radial neck fractures in children.From January 2011 to April 2013, we treated 16 cases of angulated radial neck fracture in 12 boys and 4 girls. Five fractures were type II and 11 fractures were type III using the O'Brien classification. One K-wire was percutaneously introduced into the fracture site using the leverage technique to attain good reduction. Two K-wires were introduced from the proximal to the distal areas of the fracture site. The elbow was immobilized by cast in 90° of flexion and the forearm in supination for 3 to 4 weeks. The K-wires were removed at 3 to 4 weeks postoperatively. All cases were followed up for a mean duration of 3 years 6 months.According to the Metaizeau reduction classification, 12 cases were excellent, and 4 cases were good. According to the Metaizeau clinical classification, 14 cases were excellent, and 2 cases were good. There was no necrosis of the radial head. There was no infection, radioulnar synostosis, and damage of the radial nerve deep branch. There was no limitation in the pronation and supination functions of the forearm.Closed reduction using the percutaneous leverage technique and internal fixation using K-wires is easy to perform. It is encouraged to use this approach as the clinical outcome is good.

  20. Closed reduction using the percutaneous leverage technique and internal fixation with K-wires to treat angulated radial neck fractures in children-case report

    PubMed Central

    Jiang, Hai; Wu, Yongtao; Dang, Youting; Qiu, Yusheng

    2017-01-01

    Abstract Pediatric radial neck fractures are uncommon. Severely displaced and angulated fractures usually require treatment. Our goals for treatment are to avoid incision, reduce the fracture adequately with no reduction loss, and achieve good postoperative function. We aimed to observe the clinical outcomes of closed reduction with the percutaneous leverage technique and internal fixation with Kirschner-wires (K-wires) to treat angulated radial neck fractures in children. From January 2011 to April 2013, we treated 16 cases of angulated radial neck fracture in 12 boys and 4 girls. Five fractures were type II and 11 fractures were type III using the O’Brien classification. One K-wire was percutaneously introduced into the fracture site using the leverage technique to attain good reduction. Two K-wires were introduced from the proximal to the distal areas of the fracture site. The elbow was immobilized by cast in 90° of flexion and the forearm in supination for 3 to 4 weeks. The K-wires were removed at 3 to 4 weeks postoperatively. All cases were followed up for a mean duration of 3 years 6 months. According to the Metaizeau reduction classification, 12 cases were excellent, and 4 cases were good. According to the Metaizeau clinical classification, 14 cases were excellent, and 2 cases were good. There was no necrosis of the radial head. There was no infection, radioulnar synostosis, and damage of the radial nerve deep branch. There was no limitation in the pronation and supination functions of the forearm. Closed reduction using the percutaneous leverage technique and internal fixation using K-wires is easy to perform. It is encouraged to use this approach as the clinical outcome is good. Level of evidence: level IV-retrospective case, treatment study. PMID:28072734

  1. Management of femoral fracture in a patient with essential thrombocythemia treated with plateletpheresis and intramedullary rod fixation, followed by hydroxyurea: a case report.

    PubMed

    Edlich, Richard F; Long, William B; Cochran, Amy A; Kelley, Angela R; Woode, Dayna R; Greene, Jill Amanda; Takahashi, Gary W

    2008-06-01

    We describe the management of a patient with a femoral fracture who had asymptomatic essential thrombocythemia. When the diagnosis of essential thrombocythemia was made, the patient was treated with plateletpheresis to reduce the platelet count before intramedullary rod fixation of his fracture. His postoperative management included the examination of his peripheral blood as well as bone marrow, which confirmed that the cause of his elevated platelet count was due to JAK2 V617F mutation that is treated by hydroxyurea and aspirin after being discharged from the hospital.

  2. Effect of root morphology on the susceptibility of endodontically treated teeth to vertical root fracture: An ex-vivo model.

    PubMed

    Pilo, Raphael; Metzger, Zvi; Brosh, Tamar

    2017-05-01

    Vertical root fracture (VRF) of endodontically treated teeth is relatively common, and the involved teeth have a poor prognosis. Previous destructive methodologies applied force to the root in an uneven manner; thus, the associated experiments could not truly assess the mechanical behavior of VRF. This problem was resolved in the current study via the novel application of a bursting pressure methodology to endodontically treated maxillary central incisors and premolars. Hydrostatic pressure was applied inside the root canal through a cannula bonded to the coronal access cavity, and the apical foramen was sealed. VRFs were observed as water burst from the fractured root surface. Morphometric parameters were measured by staining and serially sectioning the roots. The bursting pressure was significantly lower in the premolars compared with that in the incisors (19.1±3.3MPa and 25.5. ±4.5MPa, respectively, p=0.001). Cracks in the roots appeared from the apex to the cement enamel junction (CEJ) (61%), apex to mid-root (26%) and mid-root to CEJ (13%), and they involved either two root surfaces (52%) or one root surface (48%) and closely resembled clinical VRF cases. Positive correlations were found between the bursting pressure and the proximal root wall thickness, whereas correlations were not observed between the bursting pressure and the buccal or lingual wall thicknesses. Statistical Analyses of Covariance (ANCOVA) models showed that the proximal wall thickness and an elliptically shaped root cross section were the variables that indicated the differences in strength between premolars, which are more prone to VRF, and maxillary central incisors, which are less prone to VRF.

  3. Preliminary Biomechanical Study of Different Acetabular Reinforcement Devices for Acetabular Reconstruction

    PubMed Central

    Tai, Ching-Lung; Lee, Po-Yi; Hsieh, Pang-Hsing

    2015-01-01

    Background Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct. However, all commercially available ARDs are designed with non-locking fixation. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction. Methods Three types of ARDs were examined to evaluate the postoperative compression and angular stability: i) standard commercial ARDs, ii) standard ARDs modified with monoaxial and iii) standard ARDs modified with polyaxial locking screw mechanisms. All ARDs were implanted into osteomized synthetic pelvis with pelvic discontinuity. Axial compression and torsion tests were then performed using a servohydraulic material testing machine that measured load (angle) versus displacement (torque). Initial stability was compared among the groups. Results Equipping ARDs with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs. In both compression and torsion experiments, the monoaxial interlocking construct demonstrated the highest construct stiffness (672.6 ± 84.1 N/mm in compression and 13.3 ± 1.0 N·m/degree in torsion), whereas the non-locked construct had the lowest construct stiffness (381.4 ± 117.2 N/mm in compression and 6.9 ± 2.1 N·m/degree in torsion) (P < 0.05). Conclusions Our study demonstrates the potential benefit of adding a locking mechanism to an ARD. Polyaxial ARDs provide the surgeon with more flexibility in placing the screws at the cost of reduced mechanical performance. This in vitro study provides a preliminary evaluation of biomechanical performance for ARDs

  4. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip...

  5. Long-Term Outcome of Acetabular Reconstruction Using a Kerboull-Type Acetabular Reinforcement Device with Hydroxyapetite Granule and Structural Autograft for AAOS type II and III Acetabular Defects.

    PubMed

    Kim, Youngwoo; Tanaka, Chiaki; Kanoe, Hiroshi

    2015-10-01

    We evaluated the clinical results of the reconstruction of acetabular bone deficiency using hydroxyapatite (HA) granules and structural autografts supported by a Kerboull-type acetabular reinforcement device at a minimum of 10 years follow-up. Between 1993 and 2003, 40 consecutive THA revisions were performed in 37 patients with a mean age of 66.4 years. The mean follow-up period was 12.8 years. Radiologically, 5 hips failed, of which 2 were revised. The survival rate of the acetabular component at 10 years was 100% in type II defects and 94.9% in the type III defects, using acetabular revision for loosening as the end point. Acetabular reconstruction with HA granules, structural autografts and a Kerboull-type acetabular reinforcement device provided satisfactory clinical and radiological results at 12.8 years postoperatively.

  6. Risk of infection and secondary displacement in pediatric supracondylar or lateral condyle fractures treated with unburied Kirchener-wires removed before complete bone healing.

    PubMed

    Aubret, Sylvain; Lecointe, Thibaut; Mansour, Mounira; Rousset, Marie; Andreacchio, Antonio; Pereira, Bruno; Charles, Yann Philippe; Canavese, Federico

    2016-11-29

    This study evaluated the risk of infection and of secondary displacement among children with displaced lateral condyle or supracondylar fractures treated by surgery. The study included a consecutive sample of 84 supracondylar fractures and 21 lateral condyle fractures treated with closed reduction and percutaneous pinning. The mean time to Kirchener wire removal was 29 days (range: 25-37 days) postsurgery. Two out of 105 (1.9%) patients developed infectious complications and two of 105 (1.9%) patients had a secondary displacement. Removal of unburied Kirchener wires before complete bone healing in the physician's office does not increase risk of infection or the risk of secondary displacement. The protocol does, however, enable significant savings and eliminates the need for additional anaesthetic.

  7. Bryan and Morrey type IV intra-articular fracture of the distal extremity of the humerus treated surgically with anterior access: case report.

    PubMed

    Dressler, Hugo Bertani; de Paula, Ricardo Nunes Borges

    2015-01-01

    Within the context of elbow-level trauma, fractures with a coronal line at the distal extremity of the humerus are rare and result from indirect axial trauma with the arm extended. These are difficult-to-treat intra-articular fractures, since they require stable anatomical reduction in order to maintain joint congruence and diminish complications such as stiffness. This paper reports a case that occurred in a young man who suffered a fall from a ladder that resulted in a Bryan and Morrey type IV intra-articular fracture of the humerus. The injury was treated surgically by means of an anterior access, using osteosynthesis with two Herbert screws that were inserted from anterior to posterior.

  8. Hip and other fragility fracture incidence in real-world teriparatide-treated patients in the United States.

    PubMed

    Burge, R T; Disch, D P; Gelwicks, S; Zhang, X; Krege, J H

    2017-03-01

    This study demonstrates real-world effectiveness of teriparatide in reducing the risk of hip and other fragility fractures. Fracture incidence significantly decreased as adherence and persistence increased for any clinical, vertebral, nonvertebral, and hip fractures among patients who were observed for 2 years after teriparatide initiation.

  9. Comparative evaluation of fracture resistance of glass fiber reinforced, carbon, and quartz post in endodontically treated teeth: An in-vitro study

    PubMed Central

    Sharma, Shweta; Attokaran, George; Singh, Kunwar S.; Jerry, Jeethu J.; Ahmed, Naima; Mitra, Nirban

    2016-01-01

    Aim and Objectives: Use of posts improves the physical properties of endodontically-treated teeth. Different post types are developed such as metal, custom-made, carbon, and quartz. The present study was conducted to evaluate the fracture resistance of glass fiber-reinforced, carbon, and quartz post in endodontically-treated teeth. Materials and Methods: Forty extracted human maxillary incisor teeth were decoronated and endodontically treated and equally divided into 4 groups; control, glass fiber-reinforced, carbon, and quartz posts. No post was used in the control group. Post space was prepared and cemented with different posts and subjected to universal testing machine to check fracture resistance. The data were statistically analyzed using t-test and analysis of variance to compare the mean difference between groups (SPSS version 20, IBM). Results: Quartz type of endodontic post showed good fracture resistance compared to carbon and resin-reinforced post. Least resistance was observed in the control group without post. Conclusion: Quartz, carbon, and glass fiber-reinforced posts show good resistance to fracture, and hence can be used in endodontically-treated teeth to enhance their strength. PMID:27583227

  10. Surface-enhanced Raman scattering study of the healing of radial fractures treated with or without Huo-Xue-Hua-Yu decoction therapy

    NASA Astrophysics Data System (ADS)

    Chen, Weiwei; Huang, Hao; Chen, Rong; Feng, Shangyuan; Yu, Yun; Lin, Duo; Lin, Jia

    2014-11-01

    This study aimed to assess, through surface-enhanced Raman scattering (SERS) spectroscopy, the incorporation of calcium hydroxyapatite (CHA ~960 cm-1) and other biochemical substances in the repair of complete radial fractures in rabbits treated with or without Huo-Xue-Hua-Yu decoction (HXHYD) therapy. A total of 18 rabbits with complete radial fractures were randomly divided into two groups; one group was treated with HXHYD therapy and the other without therapy acted as a control. The animals were sacrificed at 15, 30 and 45 d after surgery. Specimens were routinely prepared for SERS measurement and high quality SERS spectra from a mixture of bone tissues and silver nanoparticles were obtained. The mineral-to-matrix ratios from the control and treated groups were calculated. Results showed that both deposition content of CHA measured by SERS spectroscopy and the mineral-to-matrix ratio in the treated group were always greater than those of the control group during the experiment, demonstrating that HXHYD therapy is effective in improving fracture healing and that SERS spectroscopy might be a novel tool to assess fracture healing.

  11. The effect of marginal ridge thickness on the fracture resistance of endodontically-treated, composite restored maxillary premolars.

    PubMed

    Shahrbaf, Shahrbaf; Mirzakouchaki, Behnam; Oskoui, Siavash Savadi; Kahnamoui, Mehdi Abed

    2007-01-01

    This study evaluated the effect of varying thicknesses of marginal ridge on the fracture resistance of endodontically-treated maxillary premolars restored with composite. Ninety non-carious maxillary premolars, extracted for orthodontic reasons, were selected for this experimental in vitro study. The teeth were randomly assigned to six groups (n=15). Group 1 received no preparation. In groups 2 through 6, the premolars were root filled and DO preparations were created, while MOD preparations were also created for group 2. The condition of the boxes was: the gingival seat was 1.5 mm above the CEJ and the buccolingual dimensions were 3.5 mm in gingival and 3 mm in occlusal. In groups 3 through 6, the dimensions of the mesial marginal ridge were measured using a digital caliper as follows: 2 mm, 1.5 mm, 1 mm and 0.5 mm, respectively. All samples in groups 2 through 6 were restored with a dentin bonding system (DBS: Single Bond, 3M) and resin composite (Z 250, 3M). Subsequently, premolars from all six groups were subjected to a thermocycling regimen of 500 cycles between 5 degrees C and 55oC water baths. Dwell time was 30 seconds, with a 10-second transfer time between baths. The premolars were submitted to axial compression up to failure at a 45 degrees angle to the palatal cusp in Universal Test Equipment (Tinius Olsen, Ltd, H5K-S model). The mean load necessary to fracture the samples was recorded in newtons (N), and data were subjected to analysis of variance (ANOVA) and LSD post-hoc test. According to these results, the mean loads necessary to fracture the samples in each group were (in N): group 1: 732 +/- 239, group 2:489 +/- 149, group 3: 723 +/- 147, group 4: 696 +/- 118, group 5: 654 +/- 183 and group 6: 506 +/- 192). Differences between group 1 and groups 2 and 6, and also differences between groups 3, 4 and 5 compared with group 2 and 6 were statistically significant (p < 0.05).

  12. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    PubMed Central

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; Tang, Simon; Amling, Michael; Ritchie, Robert O.; Busse, Björn

    2016-01-01

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibril deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. The significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates. PMID:26879146

  13. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    SciTech Connect

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; Tang, Simon; Amling, Michael; Ritchie, Robert O.; Busse, Björn

    2016-02-16

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibril deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. We find the significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.

  14. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    DOE PAGES

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; ...

    2016-02-16

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibrilmore » deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. We find the significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.« less

  15. Intrinsic mechanical behavior of femoral cortical bone in young, osteoporotic and bisphosphonate-treated individuals in low- and high energy fracture conditions

    NASA Astrophysics Data System (ADS)

    Zimmermann, Elizabeth A.; Schaible, Eric; Gludovatz, Bernd; Schmidt, Felix N.; Riedel, Christoph; Krause, Matthias; Vettorazzi, Eik; Acevedo, Claire; Hahn, Michael; Püschel, Klaus; Tang, Simon; Amling, Michael; Ritchie, Robert O.; Busse, Björn

    2016-02-01

    Bisphosphonates are a common treatment to reduce osteoporotic fractures. This treatment induces osseous structural and compositional changes accompanied by positive effects on osteoblasts and osteocytes. Here, we test the hypothesis that restored osseous cell behavior, which resembles characteristics of younger, healthy cortical bone, leads to improved bone quality. Microarchitecture and mechanical properties of young, treatment-naïve osteoporosis, and bisphosphonate-treated cases were investigated in femoral cortices. Tissue strength was measured using three-point bending. Collagen fibril-level deformation was assessed in non-traumatic and traumatic fracture states using synchrotron small-angle x-ray scattering (SAXS) at low and high strain rates. The lower modulus, strength and fibril deformation measured at low strain rates reflects susceptibility for osteoporotic low-energy fragility fractures. Independent of age, disease and treatment status, SAXS revealed reduced fibril plasticity at high strain rates, characteristic of traumatic fracture. The significantly reduced mechanical integrity in osteoporosis may originate from porosity and alterations to the intra/extrafibrillar structure, while the fibril deformation under treatment indicates improved nano-scale characteristics. In conclusion, losses in strength and fibril deformation at low strain rates correlate with the occurrence of fragility fractures in osteoporosis, while improvements in structural and mechanical properties following bisphosphonate treatment may foster resistance to fracture during physiological strain rates.

  16. Evaluation of Fracture Resistance of Endodontically Treated Teeth Filled with Gutta-Percha and Resilon Obturating Material: An In Vitro Study

    PubMed Central

    Khan, Sheeba; Inamdar, Mohammed Nasir K; Munaga, Swapna; Ali, Syed Akbar; Rawtiya, Manjusha; Ahmad, Ezaz

    2015-01-01

    Background: As per many studies endodontically treated teeth are widely considered to be more susceptible to fracture than vital teeth. Obturation strains and post placement have been a major cause of vertical root fracture. Present study was conducted to compare in vitro fracture resistance after filling with either Gutta-percha or Resilon by lateral condensation techniques in root canals. This study evaluated a new thermoplastic synthetic polymer based on polyester, which contains bioactive and radiopaque filler, Resilon performs every way as Gutta-percha except that it allows the bonding agent to attach to the resin core and the dentin wall thus forming a monoblock. Materials and Methods: In the present study 90 freshly extracted single-rooted human mandibular premolar teeth endodontically treated, were cut at the cemento-enamel junction, and were randomly divided into three groups of 30 each as teeth of Group A (Control) received no obturation, Group B teeth were obturated using Gutta-percha/AH26, and Group C teeth were obturated using Resilon/Epiphany obturating kit. Each specimen were mounted in acrylic in a polyvinyl ring and then tested for fracture resistance with the help of an universal testing machine. A compressive force was applied until the root is fractured. The data were subjected to analysis of variance for comparing mean difference of fracture resistance among three groups. Multiple comparisons among these groups were carried out by non-parametric Kruskal–Wallis analysis. A p value of <0.0001 was considered a statistically significant difference. Results: The results obtain after analysis showed no significant differences in the fracture resistance between the two tested groups of endodontic sealers. Conclusion: Within the limitation of the present in-vitro study, Resilon/Epiphany sealer performs better than Gutta-percha/AH 26 sealer with lateral condensation technique. PMID:26668476

  17. Intra-articular Fractures of the Sigmoid Notch of the Distal Radius: Analysis of Progression to Distal Radial Ulnar Joint Arthritis and Impact on Upper Extremity Function in Surgically Treated Fractures.

    PubMed

    Vitale, Mark A; Brogan, David M; Shin, Alexander Y; Berger, Richard A

    2016-03-01

    Background Studies have established an increased risk of radiocarpal joint posttraumatic arthritis in patients with displaced intra-articular fractures of the distal radius, although this phenomenon has yet to be evaluated in the distal radioulnar joint (DRUJ). Purpose We hypothesized that patients with displaced intra-articular fractures of the sigmoid notch would have a higher prevalence of DRUJ arthritis and greater upper extremity dysfunction after operative treatment of distal radius fractures compared with fractures without sigmoid notch involvement. We also hypothesized that the degree of sigmoid notch incongruity would be correlated with the grade of DRUJ arthritis and the severity of upper extremity dysfunction. Patients and Methods A retrospective review was conducted on surgically treated patients with distal radius fractures with pre- and/or postoperative computed tomography (CT) scans. Patients were divided into groups based on presence or absence of fracture extension into the sigmoid notch. Within the sigmoid notch group, postoperative CT scans were used to measure sigmoid notch fracture step-off and diastasis (mm), as well as volar or dorsal DRUJ subluxation (%). Patients were administered Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaires and radiographs were obtained to grade DRUJ arthritis using the Kellgren-Lawrence (KL) radiographic criteria. Results Thirty-three patients were included (19 with sigmoid notch involvement and 14 without) with an average radiographic follow-up of 6.3 years (range: 3.5-10.1 years). DASH scores were available for all patients, and radiographic follow-up was available in 24 patients (73%). A trend toward higher grade of DRUJ arthritis and poorer average DASH was found in those with sigmoid notch involvement, but was not statistically different. In the sigmoid notch group there were poorer DASH scores in patients with coronal step-off > 1.0-mm (p < 0.05). There were no significant

  18. Intraoperative computed tomography navigation for transpedicular screw fixation to treat unstable thoracic and lumbar spine fractures: clinical analysis of a case series (CARE-compliant).

    PubMed

    Lee, Ching-Yu; Wu, Meng-Huang; Li, Yen-Yao; Cheng, Chin-Chang; Hsu, Chu-Hsiang; Huang, Tsung-Jen; Hsu, Robert Wen-Wei

    2015-05-01

    Transpedicular screw (TPS) fixation in unstable thoracic and lumbar (TL) spine fractures remains technically difficult because of destroyed anatomical landmarks, unstable gross segments, and discrepancies in anatomic orientation using conventional anatomic landmarks, fluoroscopic guidance, or computed tomography (CT)-based navigation. In this study, we evaluated the safety and accuracy of TPS placement under intraoperative computed tomography (iCT) navigation in managing unstable TL spine fractures.From 2010 to 2013, we retrospectively reviewed the Spine Operation Registry records of patients who underwent posterior instrumented fusion to treat unstable TL spine fractures via the iCT navigation system. An unstable spine fracture was identified as AO/Magerl classification type B or type C.In all, 316 screws in 37 patients with unstable TL spine fractures were evaluated and involved 7 thoracic, 23 thoracolumbar junctional, and 7 lumbar fractures. The accuracy of TPS positioning in the pedicle without breach was 98% (310/316). The average number of iCT scans per patient was 2.1 (range 2-3). The average total radiation dose to patients was 15.8 mSv; the dose per single level exposure was 2.7 mSv. The TPS intraoperative revision rate was 0.6% (2/316) and no neurovascular sequela was observed. TPS fixation using the iCT navigation system obtained a 98% accuracy in stabilizing unstable TL spine fractures. A malplaced TPS could be revised during real-time confirmation of the TPS position, and no secondary operation was required to revise malplaced screws.The iCT navigation system provides accurate and safe management of unstable TL spine fractures. In addition, operating room personnel, including surgeons and nurses, did not need to wear heavy lead aprons as they were not exposed to radiation.

  19. Analysis of version in the acetabular cup.

    PubMed

    Seradge, H; Nagle, K R; Miller, R J

    1982-06-01

    To determine the amount of anteversion or retroversion of the acetabular component of the implanted total hip prosthesis, two anteroposterior radiographs of the hip are obtained, with the contralateral hip flexed to compensate for the possible existing flexion contracture. The X-ray beam is centered on the implanted total hip in one radiograph, and moved away from it toward the contralateral hip in the second radiograph. If the cup is anteverted, the opening will seem wider in the second radiograph. To calculate the angle, the location of the center of the X-ray beam on the X-ray plate must be know. The center of the X-ray beam can be marked on the radiograph by putting a metalic cross on the patient, over the centering cross of the X-ray light source. If the distance of the signature of the X-ray's center beam is less than 8 mm for the center of the cup on the X-ray film, the cup version can be calculated from the arcsin of the shortest to the largest diameter of the cup. If the central ray's signature is farther away, correction is necessary for this calculation. Also, the variable parameters, e.g., cup size, and magnification rate, should be considered in the calculations. The anteroposterior radiographs of the implanted total hip, obtained with the central beam being marked on the X-ray plate, not only are useful for evaluation of the implant but also can be used to calculate the version angle with an accuracy of +/-2 degrees. The necessary calculation is tabulated for cups with an outside diameter of 44-56 mm.

  20. Fracture resistance of endodontically treated premolars restored with lithium disilicate CAD/CAM crowns or onlays and luted with two luting agents.

    PubMed

    Yu, Weiqiang; Guo, Kewu; Zhang, Baowei; Weng, Weimin

    2014-01-01

    The purpose of the present study is to evaluate the fracture resistance of endodontically treated maxillary premolars restored using CAD/CAM onlays or crowns and luted with two types of resin cement. Forty all-ceramic crowns and twenty onlays were fabricated on maxillary premolars using the Cerec 3 system (n=10). The abutments were randomly subjected to two different procedures: Endodontic treatment was performed on forty teeth restored through a mesio-occlusal-distal (MOD) cavity preparation with composite resin fillings; twenty teeth without endodontic treatment served as control. In endodontically treated teeth restored using IPS e.max CAD crowns or onlays, the fracture loads were lower than those of the control. Endodontic treatment of teeth restored using CAD/CAM crowns does not impair the fracture load but shows more severe fractures than teeth restored using CAD/CAM onlays. This suggests that a CAD/CAM onlay might be an effective method for the restoration of endodontically treated premolars with MOD cavity defect.

  1. Medium-term results of cementation of a highly cross-linked polyethylene liner into a well-fixed acetabular shell in revision hip arthroplasty.

    PubMed

    Lim, Seung-Jae; Lee, Keun-Ho; Park, Shin-Hyung; Park, Youn-Soo

    2014-03-01

    The present study was undertaken to document outcomes of cementation of a highly cross-linked polyethylene (PE) liner into a well-fixed acetabular metal shell in 36 hips. All operations were performed by a single surgeon using only one type of liner. Patients were followed for a mean of 6.1 years (range, 3-8 years). Mean Harris hip score improved from 58 points preoperatively to 91 points postoperatively. There were no cases of PE liner dislodgement or progressive osteolysis. 1 hip (2.8%) required revision surgery for acetabular cup loosening with greater trochanteric fracture. Complications included 1 peroneal nerve palsy and 1 dislocation. The results of this study and previous reports demonstrated that cementation of highly cross-linked PE liner into well-fixed metal shell could provide good midterm durability.

  2. [Postoperative morbidity in surgically treated extension fractures of the distal radius. A comparative study of dorsal and volar approach].

    PubMed

    Zettl, R P; Ruchholtz, S; Taeger, G; Obertacke, U; Nast-Kolb, D

    2001-08-01

    The aim of this study was to investigate perioperative morbidity in operative interventions in distal radiusfractures, comparing the operative approach from volar and dorsal. Only problems, resulting from the operative approach towards the distal aspect of the radius, were examined. In a Case-Control-Study, we investigated patients with operative by plate-osteosynthesis treated distal radius-extensions-fractures. During 3 years we investigated 92 patients. 49 were operated with a volar approach, and after changing the operative management, consecutive 43 patients with a dorsal approach to the distal radius. Indications for operative treatment were not changed. The approach to the distal aspect of the radius corresponded to the recent guidelines. Further perioperative procedures were identical, including procedures in anesthesiology. Datas of patients have been investigated for epidemiology, kind of operations, point of time in treatment, duration of operation, X-Ray, immobilisation and time of inhospital stay as well as all documented complications. It has been shown, that in respect of all criterias, concerning length of operation (106 vs. 83 min), intraoperative X-Ray (3.0 vs. 1.65 min) as well as postoperative immobilisation (33 vs. 25 days), and documented incidences of complications like secondary wound-healing (19/49 vs. 0/43) or nerval irritations (13/49 vs. 1/43), the dorsal osteosynthesis is definitively to be favored.

  3. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    PubMed Central

    DeBuitleir, Cathal; Soden, Philip; O'Donnchadha, Brian; Tansey, Anthony; Abdulkarim, Ali; McMahon, Colm; Hurson, Conor J.

    2017-01-01

    Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D) representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice. PMID:28168060

  4. Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature

    PubMed Central

    Figueras, Guillem; Planell, Ramón Vives; Fernàndez, Ramón Serra; Biayna, Joan Camí

    2016-01-01

    Background: As a consequence of use of metal-on-metal hip arthroplasties some patients have precised revision for pain or metal hipersensivity reactions among other causes. We propose to salvage monoblock acetabular component and femoral component using a dual-mobility head and perform a lower morbidity operation in young patients preserving host bone stock in cases with well fixed and positioned components. Objective: (1) What clinical problems have been reported in patients with Metal-on-metal hip arthroplasties? (2) Could the tribocorrosion potentially cause a fracture of neck femoral component? (3) Can be the dual-mobility head a recourse in metal-on-metal hip revision? Methods: Ten patients were revised for pain or/and raised Cobalt/Chromium levels between August 2012 and December 2015. In three cases femoral neck component was fractured and femoral revision was necessary. In four hips, acetabular and femoral components could be maintained. Age, body index mass, ion levels, acetabular position, size of acetabular component and femoral head, approach, blood transfunsion and time of hospitalization were analized. Results: At a mean follow-up of 25,6 months (6 to 45) the mean postoperative HHS was 92. It was not statistically significant because several patients were low sintomatic before surgery, but had raised Cobalt/Chromium levels in the blood. All patients had near-normal levels of Cobalt/Chromium during the first 6 months after revision surgery. No relevant complications were reported. Conclusion: The use of dual-mobility head can be an acceptable option to revise metal-on-metal arthroplasties correctly oriented with abscence of loosening or infection signs and keeping bone stock in young patients. PMID:27857822

  5. Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures

    PubMed Central

    2014-01-01

    Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833

  6. Pathological fracture of the femur in Alagille syndrome that was treated with low-intensity pulsed ultrasound stimulation and an Ilizarov ring fixator: a case report

    PubMed Central

    2014-01-01

    Background Alagille syndrome is a multisystem disorder, which is characterized by hypoplasia of the intrahepatic bile ducts, malformations of the cardiovascular system, eyes, and vertebral column, and abnormal facies. Several of the characteristics of Alagille syndrome may result in an especially high risk of fracture. The majority of patients suffer from chronic cholestasis, which can have a variety of adverse effects on bone metabolism. In Alagille syndrome, fractures primarily occur in the lower limb long bones in the absence of significant trauma. Case presentation A 9-year-old Japanese girl with Alagille syndrome was admitted to our institution with marked hyperbilirubinemia and a pathological fracture of the femur. She had been diagnosed with biliary atresia at the age of 1 month and treated with surgical bile duct reconstruction, vitamins D and K, and ursodeoxycholic acid. However, her liver dysfunction and hyperbilirubinemia worsened. The pathological fracture of the femur was treated with low-intensity pulsed ultrasound stimulation (LIPUS) and an Ilizarov ring fixator. Seventy-four days after surgery, the patient had anatomically and functionally recovered. There was no leg-length discrepancy and no angular malalignment of the lower extremities as measured clinically and radiographically. The range of motion of the hip, knee, and ankle of the patient’s operative leg matched the range of motion in the nonoperative leg. Conclusion To the best of our knowledge, there are no reports on use of the Ilizarov frame and LIPUS in diaphyseal femoral fractures in Alagille syndrome. This case report provides evidence that this procedure is successful for managing such diaphyseal fractures in Alagille syndrome. PMID:25004954

  7. Epidemiological profile of 277 patients with facial fractures treated at the emergency room at the ENT Department of Hospital do Trabalhador in Curitiba/PR, in 2010

    PubMed Central

    Ykeda, Renier Barreto Arrais; Ballin, Carlos Roberto; Moraes, Rafael Souza; Ykeda, Ronnie Barreto Arrais; Miksza, Alana Farias

    2012-01-01

    Summary Introduction: Epidemiological studies that focus on facial injuries are of great interest for the knowledge of occurrence and severity of presentation. Aim: To study the epidemiological profile of 277 patients who suffered facial fractures at the Hospital do Trabalhador (HT), with an emphasis on variables such as sex, age, cause, and anatomical sites of fractures, comparing the clinical findings with other studies. Method: Retrospective nonrandomized chart review of 277 patients who were treated at HT by the ENT service during the full year 2010, victims of facial fractures. Results: Of 277 patients, 74.72% were male and 25.27% female (ratio 3:1). According to age, the fractures were distributed as follows: 0–9 years: 4.69%, 10–19 years: 17.32%, 20–29 years: 23.82%, 30–39 years: 20.21%, 40–49 years: 16.24%, 50–59 years: 10.83%, 60–69 years: 3.97%, and 60–79 years: 2.88%. The cause of trauma was most frequently interpersonal violence, 36.45%, followed by falls, 23.09%, and motor vehicle crashes with 17.32%. Regarding location, nasal fracture was the most common, with 44.75%, followed by the mandible, 14.32%, orbit, 12.78%, maxillary, 12.02%, zygomatic, 9.97%, 3.32% and front Le Fort 2.88%. Conclusion: The patients were mostly males, aged 21–30 years, victims of aggression with the most commonly fractured bone being the nose. The adoption of personal and public strategies and measures may prevent facial fractures. PMID:25991971

  8. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study.

    PubMed

    Ma, Ching-Hou; Wu, Chin-Hsien; Tu, Yuan-Kun; Lin, Ting-Sheng

    2013-08-01

    We evaluated both the outcome of using a locking plate as a definitive external fixator for treating open tibial fractures and, using finite element analysis, the biomechanical performance of external and internal metaphyseal locked plates in treating proximal tibial fractures. Eight open tibial patients were treated using a metaphyseal locked plate as a low-profile definitive external fixator. Then, finite element models of internal (IPF) as well as two different external plate fixations (EPFs) for proximal tibial fractures were reconstructed. The offset distances from the bone surface to the EPFs were 6 cm and 10 cm. Both axial stiffness and angular stiffness were calculated to evaluate the biomechanical performance of these three models. The mean follow-up period was 31 months (range, 18-43 months). All the fractures united and the mean bone healing time was 37.5 weeks (range, 20-52 weeks). All patients had excellent or good functional results and were walking freely at the final follow-up. The finite element finding revealed that axial stiffness and angular stiffness decreased as the offset distance from the bone surface increased. Compared to the IPF models, in the two EPF models, axial stiffness decreased by 84-94%, whereas the angular stiffness decreased by 12-21%. The locking plate used as a definitive external fixator provided a high rate of union. While the locking plate is not totally rigid, it is clinically stable and may be advisable for stiffness reduction of plating constructs, thus promoting fracture healing by callus formation. Our patients experienced a comfortable clinical course, excellent knee and ankle joint motion, satisfactory functional results and an acceptable complication rate.

  9. Cementless acetabular fixation in patients 50 years and younger at 10 to 18 years of follow-up.

    PubMed

    Teusink, Matthew J; Callaghan, John J; Warth, Lucian C; Goetz, Devon D; Pedersen, Douglas R; Johnston, Richard C

    2012-08-01

    The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.

  10. Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims

    PubMed Central

    Wada, Hiroshi; Mishima, Hajime; Yoshizawa, Tomohiro; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    Background In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible because of direct palpation using a pointer. Imageless navigation using the ACA usually targets patients with normal acetabular morphology. The aim of this study was to investigate the accuracy of imageless navigation using the ACA instead of the APP in patients with normal or deformed acetabular rims. Methods The intraoperative cup position was compared with that obtained from the postoperative computed tomography (CT) images in 18 cases. Results The inclination angle derived from the navigation system was 3.4 ± 5.3 degrees smaller and the anteversion angle was 1.4 ± 3.1 degrees larger than those derived from the CT images. Conclusion The inclination cup angle of the navigation system was significantly inferior to the true value, particularly in cases with large anterior osteophytes. PMID:27073586

  11. Lateral acetabular labral length is inversely related to acetabular coverage as measured by lateral center edge angle of Wiberg

    PubMed Central

    Petersen, Brian D.; Wolf, Bryan; Lambert, Jeffrey R.; Clayton, Carolyn W.; Glueck, Deborah H.; Jesse, Mary Kristen; Mei-Dan, Omer

    2016-01-01

    Patients with developmental dysplasia of the hip often have compensatory labral hypertrophy, which presumably lends stability to an unstable joint. Conversely, patients with acetabular overcoverage may have small or ossified labra. The purpose of this study is to explore the interaction of labral length with the degree of acetabular hip coverage. A retrospective cohort of patients with hip pain presenting to a hip preservation center, who had undergone hip magnetic resonance imaging and AP pelvis radiographs were studied. General linear multivariate models were used to assess the association between three measures of labral length (lateral, anterior and anterior inferior locations along the acetabular rim) and the X-ray derived lateral center edge angle (LCEA) of Wiberg. Of the three acetabular labral locations measured, only the lateral labrum was associated with LCEA Wiberg (P = 0.0008). Lateral labral length increases as LCEA of Wiberg decreases. The anterior and anterior inferior labral locations did not show a predictable increase in labral length as LCEA Wiberg decreased. PMID:27583157

  12. An In Vitro Comparative Evaluation of Fracture Resistance of Custom Made, Metal, Glass Fiber Reinforced and Carbon Reinforced Posts in Endodontically Treated Teeth

    PubMed Central

    Sonkesriya, Subhash; Olekar, Santosh T; Saravanan, V; Somasunderam, P; Chauhan, Rashmi Singh; Chaurasia, Vishwajit Rampratap

    2015-01-01

    Background: Posts are used to enhance crown buildup in pulpless teeth with destructed crown portion. Different types of post are used in endodontically treated teeth. The aim of the present in vitro study was to evaluate fracture resistance of custom made, metal, glass fiber reinforced and carbon reinforced posts in endodontically treated teeth. Materials and Methods: An in vitro study was carried out on extracted 40 human maxillary central incisor teeth, which was divided into four groups with 10 samples in each group with custom made, metal post, glass fiber reinforced, and carbon reinforced posts. The samples were decoronated at cemento-enamel junction and endodontically treated. Post space was prepared and selected posts were cemented. The composite cores were prepared at the height of 5 mm and samples mounted on acrylic blocks. Later fracture resistance to the compressive force of samples was measured using Universal Testing Machine. Results: The maximum resistance to the compressive force was observed in carbon reinforced and glass fiber reinforced posts compared others which is statistically significant (P > 0.001) and least was seen in custom fabricated post. Conclusion: It is concluded that carbon reinforced fiber post and glass fiber posts showed good fracture resistance compared to custom made and metal posts. PMID:26028904

  13. The reinforcement effect of polyethylene fibre and composite impregnated glass fibre on fracture resistance of endodontically treated teeth: An in vitro study

    PubMed Central

    Luthria, Archana; Srirekha, A; Hegde, Jayshree; Karale, Rupali; Tyagi, Sanjana; Bhaskaran, Sajeev

    2012-01-01

    Aim: The aim of this study was to evaluate the fracture resistance of endodontically treated maxillary premolars with wide mesio-occluso-distal (MOD) cavities restored with either composite resin, or composite resin reinforced with different types of fibres. Materials and Methods: Fifty human maxillary premolars were selected. Five intact teeth served as positive controls. Endodontic therapy was carried out in the remaining forty-five teeth. Standardized MOD cavities were prepared in all the teeth. The teeth were restored with a nanocomposite using an incremental technique. These forty five teeth were randomly divided into three experimental groups (Group A, B and C) (n = 15). The teeth in Group A did not undergo any further procedures. The teeth in Group B and C were reinforced with composite impregnated glass fibre and polyethylene fibre, respectively. Fracture resistance was measured in Newtons (N). Results: The positive controls showed the highest mean fracture resistance (811.90 N), followed by Group B (600.49N), Group A (516.96N) and Group C (514.64N), respectively. One Way analysis of variance (ANOVA) test revealed a statistically significant difference between all the groups (P = 0.001). Post-hoc Tukey test revealed a moderately significant difference (P = 0.034) between Control and Group B, and a strongly significant difference between Control and Group A (P = 0.002), and Control and Group C (P = 0.001). Conclusions: Endodontic therapy and MOD cavity preparation significantly reduced the fracture resistance of endodontically treated maxillary premolars (P = 0.001). No statistically significant difference was found between the experimental groups (Group A, B and C) (P > 0.1). However, the fracture resistance of the composite impregnated glass fibre reinforced group was much higher than the others. PMID:23112487

  14. Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns

    PubMed Central

    SHERFUDHIN, Haneef; HOBEICH, Joseph; CARVALHO, Carlos Augusto; N. ABOUSHELIB, Moustafa; SADIG, Walid; SALAMEH, Ziad

    2011-01-01

    Objective This study investigated the effect of different ferrule heights on endodontically treated premolars. Materials and Methods Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal section was restored with hybrid composite core build-up material (Tetric Ceram, Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights were investigated: 1-mm circumferential ferrule without post and core (group 1 used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule 2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and 2-mm lingually (group 4), and finally no ferrule preparation (group 5). The fracture load and failure pattern of the tested groups were investigated by applying axial load to the ceramic crowns (n=10). Data were analyzed statistically by one-way ANOVA and Tukey’s post-hoc test was used for pair-wise comparisons (α=0.05). Results There were no significant differences among the failure load of all tested groups (P<0.780). The control group had the lowest fracture resistance (891.43±202.22 N) and the highest catastrophic failure rate (P<0.05). Compared to the control group, the use of fiber post reduced the percentage of catastrophic failure while increasing the ferrule height did not influence the fracture resistance of the restored specimens. Conclusions Within the limitations of this study, increasing the ferrule length did not influence the fracture resistance of endodontically treated teeth restored with glass ceramic crowns. Insertion of a fiber post could reduce the percentage of catastrophic failure of these restorations under function. PMID:21437466

  15. The effect of the association of NIR laser therapy BMPs, and guided bone regeneration on tibial fractures treated with wire osteosynthesis: Raman spectroscopy study.

    PubMed

    Lopes, C B; Pacheco, M T T; Silveira, L; Duarte, J; Cangussú, M C T; Pinheiro, A L B

    2007-12-14

    Bone fractures are lesions of different etiology; may be associated or not to bone losses; and have different options for treatment, such as the use of biomaterials, guided bone regeneration, techniques considered effective on improving bone repair. Laser therapy has also been shown to improve bone healing on several models. The association of these three techniques has been well documented by our group using different models. This study aimed to assess, through Raman spectroscopy, the incorporation of calcium hydroxyapatite (CHA approximately 958 cm(-1)) on the repair of complete tibial fractures in rabbits treated with wire osteosynthesis (WO); treated or not with laser therapy; and associated or not with the use of BMPs and/or Guided Bone Regeneration. Complete tibial fractures were created in 12 animals that were divided into four groups: WO; WO+BMPs; WO+laser therapy; and WO+BMPs+laser therapy. Irradiation started immediately after surgery; was repeated at every other day during 2 weeks; and was carried out with lambda 790 nm laser light (4 J/cm(2) per point, 40 mW, phi approximately 0.5 cm(2), 16J per session). Animal death occurred after 30 days. Raman spectroscopy was performed at both the surface and the depth of the fracture site. Statistical analysis showed significant difference on the concentrations of CHA between surface and depth. The analysis in each of the areas showed at the depth of the fracture significant differences between all treatment groups (p<0.0001). Significant differences were also seen between WO+BMPs+laser therapy and WO (p<0.001) and WO+laser therapy (p<0.001). At the surface, significant difference was seen only between the treatment groups and the non-fractured subjects (p=0.0001). However, no significant difference was seen between the treatment groups (p=0.14). It is concluded that the use of NIR laser therapy associated to BMPs and GBR was effective in improving bone healing on the fractured bones as a result of the increasing

  16. Assessment of Bite Force in Patients Treated with 2.0-mm Traditional Miniplates versus 2.0-mm Locking Plates for Mandibular Fracture

    PubMed Central

    Rastogi, Sanjay; Reddy, Mahendra Parvath; Swarup, Azeez Gaurav; Swarup, Divya; Choudhury, Rupshikha

    2015-01-01

    The objective of this study is to analyze the difference in bite forces in patients treated for mandibular fractures with 2.0 mm conventional and locking titanium plating system. A randomized study was performed for the treatment of fractures of mandible. In this study, 20 adult patients with isolated mandibular fracture were included. The patients were randomly allocated into two groups, that is, Group I—2.0 mm nonlocking (traditional) and Group II—2.0 mm locking plates. Bite force was evaluated at 1st, 3rd, and 6th weeks. Comparison of all the assessed parameters between both the groups depicted no significant difference in terms of pain, swelling including the incidence of infection, paresthesia, and hardware failure. Although same was true in case of bite force between both the groups at various time intervals, there was statistically significant increase in the bite force within the group comprising patients in whom locking plates was used between 1st and 3rd weeks follow-up period and highly significant increase in bite force between 1st and 6th weeks of follow-up period. The rapid improvement of bite force values when locking plates were used implies that the locking plate can be used in preference to conventional plates to achieve early mobilization with assured stability in the treatment of mandibular fractures. PMID:26889350

  17. Genu Recurvatum Deformity in a Child due to Salter Harris Type V Fracture of the Proximal Tibial Physis Treated with High Tibial Dome Osteotomy

    PubMed Central

    Beslikas, Theodoros; Christodoulou, Andreas; Chytas, Anastasios; Gigis, Ioannis; Christoforidis, John

    2012-01-01

    Salter-Harris type V fracture is a very rare injury in the immature skeleton. In most cases, it remains undiagnosed and untreated. We report a case of genu recurvatum deformity in a 15-year-old boy caused by a Salter-Harris type V fracture of the proximal tibial physis. The initial X-ray did not reveal fracture. One year after injury, genu recurvatum deformity was detected associated with significant restriction of knee flexion and limp length discrepancy (2 cm) as well as medial and posterior instability of the joint. Further imaging studies revealed anterior bone bridge of the proximal tibial physis. The deformity was treated with a high tibial dome osteotomy combined with a tibial tubercle osteotomy stabilized with malleolar screws and a cast. Two years after surgery, the patient gained functional knee mobility without clinical instability. Firstly, this case highlights the importance of early identification of this rare lesion (Salter-Harris type V fracture) and, secondly, provides an alternative method of treatment for genu recurvatum deformity. PMID:23259115

  18. Comparative Evaluation of Fracture Resistance of Endodontically Treated Teeth Obturated with Resin Based Adhesive Sealers with Conventional Obturation Technique: An In vitro Study

    PubMed Central

    Langalia, Akshay K; Dave, Bela; Patel, Neeta; Thakkar, Viral; Sheth, Sona; Parekh, Vaishali

    2015-01-01

    Background: To compare fracture resistance of endodontically treated teeth obturated with different resin-based adhesive sealers with a conventional obturation technique. Materials and Methods: A total of 60 Single canaled teeth were divided into five groups. The first group was taken as a negative control. The rest of the groups were shaped using ProFile rotary files (Dentsply Maillefer, Ballaigues, Switzerland). The second group was obturated with gutta-percha and a ZOE-based sealer Endoflas FS (Sanlor Dental Products, USA). The third group was obturated with gutta-percha and an epoxy-based sealer AH Plus (Dentsply, DeTrey, Germany). The fourth group was obturated with Resilon (Pentron Clinical Technologies, Wallingford, CT) and RealSeal sealer (Pentron Clinical Technologies). The fifth group was obturated with EndoREZ points and EndoREZ sealer (both from Ultradent, South Jordan, UT). Roots were then embedded into acrylic blocks and were then fixed into a material testing system and loaded with a stainless steel pin with a crosshead speed of 5 mm/min until fracture. The load at which the specimen fractured was recorded in Newtons. Results: It was found that forces at fracture were statistically significant for the newer resin systems, Resilon, and EndoREZ. Conclusion: It was concluded that roots obturated with newer resin systems (Resilon and EndoREZ) enhanced the root strength almost up to the level of the intact roots. PMID:25859099

  19. Acetabular Prosthetic Protrusio after Bipolar Hemi-Arthroplasty of the Hip: Case Report and Review of the literature

    PubMed Central

    Lim, Jason BT; Ang, Chia Liang; Pang, Hee Nee

    2016-01-01

    Introduction: Bipolar hemi-arthroplasty of the hip is a commonly performed procedure in elderly patients with intra-capsular fracture of the neck of the femur with good short-term results for pain relief, return to activity and morbidity. The incidence of intra-pelvic prosthesis migration or protrusion is rare and one of the inciting factors is chronic low-grade sepsis. Acetabular prosthesis protrusion poses a difficult and challenging surgical problem due to surrounding neurovascular structures. Case Presentation: We present a case report of 60-year-old Chinese female suffering from chronic sepsis of the hip joint causing acetabular prosthetic protrusion with a concomitant peri-prosthetic femoral shaft fracture secondary to a fall, 5 years post index surgery of bipolar hemiarthroplasty for an intra-capsular neck of femur fracture. This patient subsequently underwent a two-stage revision total hip arthroplasty. We aim to discuss the diagnostic approach and surgical management of this complex case of infected protruded bipolar hip hemi-arthroplasty. Conclusion: We highlight three recommendations from this clinical experience. Firstly, there should be a high index of suspicion for chronic infection in protruded prostheses following low energy trauma. Secondly, pre-operative planning for infected protruded prosthetic hips is essential, including arteriogram and a two-staged procedure to tackle possible soft tissue complications. Thirdly, the combined use of serological markers, fluid aspiration as well as intra-operative frozen section is important in the management of PJI and to confirm bacterial eradication before re-implantation. PMID:28116262

  20. Traumatic conditions of the coxofemoral joint: luxation, femoral head-neck fracture, acetabular fracture.

    PubMed

    Marchionatti, Emma; Fecteau, Gilles; Desrochers, André

    2014-03-01

    Diagnosis and treatment of traumatic conditions of the hip joint in cattle remain a challenge for the veterinarian. This article is intended to give an overview of the most common orthopedic problems of the bovine coxofemoral joint, diagnostic procedures, and treatment options.

  1. Multiobjective optimization of an electrostimulative acetabular revision system.

    PubMed

    Potratz, Carsten; Kluess, Daniel; Ewald, Hartmut; van Rienen, Ursula

    2010-02-01

    In this paper, we present a new approach for the enhancement of the bone proliferation rate by electrostimulation in the acetabular region. Based on the complex tissue structure in this area, the electric field distributions were computed by numerical means using a model based on high-resolution computed tomography scans of the acetabular area. This results in a complex, nonlinear, and discrete optimization problem. Therefore, an adapted algorithm was developed to reduce the computational effort in the order of several magnitudes. We divided the procedure into two stages: data extraction and a subsequent optimization process. The used optimization algorithm utilizes an evolutionary concept and a multidimensional definition of optimality for different, partly contradictive objective functions. Finally, we present first optimization results for different stimulation situations.

  2. Acetabular component deformation with press-fit fixation.

    PubMed

    Squire, Matthew; Griffin, William L; Mason, J Bohannon; Peindl, Richard D; Odum, Susan

    2006-09-01

    Acetabular component deformation secondary to forces encountered during insertion is a potential consequence of the press-fit technique. This study characterized the stiffness of Pinnacle 100 cups (DePuy, Warsaw, Ind) via mechanical testing and used this information with intraoperative measurements of cup deformation to calculate the in vivo forces acting on cups inserted during hip arthroplasty in 21 patients. We found that 90.5% of cups had measurable compression deformity, averaging 0.16 +/- 0.16 mm. The corresponding forces acting on these cups averaged 414 +/- 421 N. For hard-on-hard bearing surfaces, such in vivo deformation of acetabular shells may result in negative clinical consequences such as equatorial loading with increased wear and potential seizing of components, chipping of ceramic inserts, or locking mechanism damage.

  3. Para-acetabular periarthritis calcarea: its radiographic manifestations.

    PubMed

    Kawashima, A; Murayama, S; Ohuchida, T; Russell, W J

    1988-01-01

    On retrospective reviews of radiographs, periarthritis calcarea was distinguished from os acetabula by interval radiographic progression and regression. Among 59 men and 51 women, there were 137 instances of para-acetabular calcifications and ossifications, which were morphologically classified as 58 discrete, 58 amorphous, and 21 segmented types. Correlations with other radiographic abnormalities, symptoms, signs, and laboratory abnormalities were sought, but not established. Out of 93 serially imaged opacities, 90 changed, including 37 of the 40 instances (92.5%) of the discrete type and 53 instances (100%) of the amorphous and segmented types--due to periarthritis calcarea. At least 43 of 90 densities were newly developed. Mean age at first detection was 47.7 years. Three of the discrete densities were unchanged and represented os acetabula. Thus, recognition of para-acetabular periarthritis calcarea is not only of academic importance; it can facilitate proper treatment as well.

  4. The effect of incomplete crown ferrules on fracture resistance and failure modes of endodontically treated maxillary incisors restored with quartz fiber post, composite core, and crowns

    PubMed Central

    Muangamphan, Panorjit; Sattapan, Boonrat; Kukiattrakoon, Boonlert; Thammasitboon, Kewalin

    2015-01-01

    Aim: To investigate the fracture resistance of restored endodontically treated teeth (RETT) with fiber posts, cores, and crowns with limited ferrules. Materials and Methods: Sixty maxillary anterior teeth were endodontically treated and decoronated 2 mm above the cemento-enamel junction, and then divided into 6 groups of 10 teeth each; Group circumferential ferrule (2FR), Group ferrule in the labial, mesial, and palatal region (2FR-LaMPa), Group ferrule in the labial, and palatal region (2FR-LaPa), Group 2FR-Pa and 2FR-La respectively, and Group 0FR (no ferrule). All 60 prepared teeth were then restored with quartz fiber posts, resin composite cores, and metal crowns. The specimens were subjected to load until failure occurred. Data were analyzed using one-way analysis of variance and Tukey's tests (α = 0.05). The mode of failure was determined under a stereoscope. Results: A statistical significant difference was found among groups 2FR-LaMPa, 2FR-Pa, 2FR-LaPa, and 2FR from the group 2FR-La, and from the group 0FR (P < 0.01). The predominant mode of failure was an oblique palatal to labial root fracture for the groups with remaining ferrules. Conclusion: For RETT that have incomplete crown ferrules, the location of the ferrules may affect their fracture resistance. PMID:26069401

  5. Fracture resistance of endodontically treated teeth with different heights of crown ferrule restored with prefabricated carbon fiber post and composite resin core by intermittent loading.

    PubMed

    de Oliveira, Jonas Alves; Pereira, Jefferson Ricardo; Lins do Valle, Accácio; Zogheib, Lucas Villaça

    2008-11-01

    This study evaluated the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber posts and varying quantities of coronal dentin. Sixty freshly extracted upper canines were randomly divided into groups of 10 teeth each. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis. Data were analyzed by 1-way analysis of variance and Tukey test (alpha = .05). Significant differences (P < .001) were found among the mean fracture forces of the test groups (positive control, 0 mm,1 mm, 2 mm, 3 mm, and negative control groups: 1022.82 N, 1008.22 N, 1292.52 N, 1289.19 N, 1255.38 N, and 1582.11, respectively). These results suggested that the amount of coronal dentin did not significantly increase the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber post and composite resin core.

  6. Fracture Resistance of Endodontically-treated Maxillary Premolars Restored with Composite Resin along with Glass Fiber Insertion in Different Positions

    PubMed Central

    Jafari Navimipour, Elmira; Ebrahimi Chaharom, Mohammad Esmaeel; Alizadeh Oskoee, Parnian; Mohammadi, Narmin; Bahari, Mahmoud; Firouzmandi, Maryam

    2012-01-01

    Background and aims The aim was to evaluate the effect of three methods of fiber insertion on fracture resistance of root-filled maxillary premolars in vitro. Materials and methods Sixty extracted human maxillary premolars received endodontic treatment followed by preparation of mesioocclusodistal (MOD) cavities, with gingival cavosurface margin 1.5 mm coronal to the cementoenamel junction (CEJ). Subsequently, the samples were randomly divided into four groups: no-fiber group; occlusal fiber group (fiber was placed in the occlusal third); circumferential fiber group (fiber was placed circumferentially in the cervical third); and dual-fiber group (occlusal and circumferential fibers). Subsequent to restoring with composite resin and thermocycling, a compressive force was applied until fracture. Data was analyzed using one-way ANOVA and Tukey test at significance levels of P < 0.05 and P < 0.02, respectively. Results Fiber placement significantly increased fracture resistance. Fracture resistance in the dual-fiber group was significantly higher than that in the circumferential fiber group (P < 0.007); however, there were no significant differences between the dual-fiber and occlusal fiber groups (P = 0.706). The highest favorable fracture rate was observed in the circumferential fiber group (60%). Conclusion Composite resin restoration along with glass fiber in the occlusal and gingival thirds can be an acceptable treatment option for restoring root-filled upper premolars. PMID:23277858

  7. Isolated fracture-dislocation of the scaphoid's proximal pole treated by scaphoid internal fixation and scapho-lunate ligament reconstruction.

    PubMed

    Rosati, Marco; Parchi, Paolo; Lisanti, Michele

    2009-05-01

    We present a case of irreducible palmar dislocation of the proximal fragment of a scaphoid fracture without carpal dislocation. We observed this lesion 2 days after the injury and we immediately operated the patient with a combined volar and dorsal access: using the Henry access we reduced the fracture and we inserted a cannulated screw to synthesize the scaphoid, using the dorsal access we repaired the complete rupture of the scapho-lunate ligament using a mini anchor. Stabilization among scaphoid, lunate and capitate was performed using Kirschner wires. X-ray showed fracture healing after 90 days. No clinical or radiographic evidence of carpal instability was revealed, on standard X-rays or on dynamic evaluations. No sign of avascular necrosis or degenerative arthritis was observed after 9 months.

  8. Heterotopic ossification of the elbow after closed reduction and retrograde intramedullary nailing for radial neck fracture treated by anconeus interposition.

    PubMed

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2013-12-01

    Heterotopic ossification around the elbow can lead to considerable functional disability. We describe a case of a 42-year-old man who developed heterotopic ossification of his elbow after closed reduction of the elbow dislocation and radial neck fracture and retrograde intramedullary nailing for radial neck fracture. During the follow-up after initial surgery, movements of the elbow were gradually deteriorated and diagnosed as heterotopic ossification of the elbow. Implant removal, radial head excision along with heterotopic mass, and also interposition of the anconeus muscle resulted in improvement of his elbow mobility. At 18 months of follow-up, patient had elbow flexion arc of 15°-110°, 70° of supination, and 50° of pronation without recurrence of heterotopic ossification. The uniqueness of this case lies in the treatment of heterotopic ossification of the elbow to prevent its recurrence, which was developed after retrograde intramedullary nailing for radial neck fracture following closed reduction.

  9. The Role of Lunate Morphology on Scapholunate Instability and Fracture Location in Patients Treated for Scaphoid Nonunion

    PubMed Central

    Kim, Byoung-Jin; Kovacevic, David; Lee, Young-Min; Seol, Jong-Hwan

    2016-01-01

    Background To determine the association between lunate morphology and the scapholunate instability using radiographic images, and investigate the association between lunate morphology and scaphoid fracture location. Methods Between January 2003 and December 2011, we retrospectively evaluated the plain radiographs and computed tomography (CT) images of 70 patients who underwent surgical intervention for a scaphoid nonunion, in order to determine the association between lunate type (I or II) and scapholunate instability or scaphoid fracture location. We determined the scaphoid fracture location using the fragment ratio and measured the radiolunate angle and capitate-triquetrum (C-T) distance. Results A type II lunate was present in 68.6% (48 of 70 cases). Mean fragment ratio of fracture location was 50.6% in the type II lunate group and 56.2% in the type I lunate group (p = 0.032). Sixteen of the 70 patients had dorsal intercalated segmental instability (DISI) deformities. Nine of 22 cases showed DISI deformity in type I lunate and 7 of 48 cases showed DISI deformity in type II lunate (p = 0.029). However, there were no significant differences between the presence of DISI deformity and fracture location (p = 0.15). Morphologic comparisons by both plain radiography and CT indicated a mean C-T distance in the type I lunate group (22 cases) of 2.3 mm and 5.0 mm in the type II lunate group (48 cases). The C-T distances were significantly correlated with lunate morphology (p = 0.001). Conclusions A type II lunate was associated with low incidence of DISI deformity and proximal location of fracture in patients presenting with a scaphoid nonunion. PMID:27247743

  10. Use of resin-bonded partial coverage ceramic restorations to treat incomplete fractures in posterior teeth: a clinical report.

    PubMed

    Liebenberg, W H

    1996-11-01

    The objective of restorative treatment of teeth with incomplete fractures is to minimize flexure of the compromised cusps to prevent propagation of the crack. These goals can be addressed with resin-bonded posterior ceramic restorations, but long-term integrity rests on the efficiency of the restoration's bond to the dental hard tissues. Success is dependent on diligent operative performance throughout the entire procedure. Some tips for achieving successful preparation, provisionalization, and partial-coverage restoration of the incompletely fractured posterior tooth are discussed.

  11. A Case of Nasu-Hakola Disease without Fractures or Consanguinity Diagnosed Using Exome Sequencing and Treated with Sodium Valproate

    PubMed Central

    Yamazaki, Kiyohiro; Yoshino, Yuta; Mori, Yoko; Ochi, Shinichiro; Yoshida, Taku; Ishimaru, Takashi; Ueno, Shu-ichi

    2015-01-01

    Nasu-Hakola disease (NHD) is a rare autosomal recessive neuropsychiatric disorder characterized by bone cysts, fractures, and cognitive impairment. Two genes are responsible for the development of NHD; TYROBP and TREM2. Although it presents with typical signs and symptoms, diagnosing this disease remains difficult. This case report describes a male with NHD with no family or past history of bone fractures who was diagnosed using exome sequencing. His frontal lobe psychiatric symptoms recovered partially following treatment with sodium valproate, but not with an antipsychotic. PMID:26598595

  12. Nose fracture

    MedlinePlus

    Fracture of the nose; Broken nose; Nasal fracture; Nasal bone fracture; Nasal septal fracture ... A fractured nose is the most common fracture of the face. It ... with other fractures of the face. Sometimes a blunt injury can ...

  13. [Rarely seen fractures].

    PubMed

    Subaşi, M; Kapukaya, A; Kesemenli, C; Coban, V

    2001-10-01

    Rarely seen fractures are presented in this study. One case was a calcaneal spur, 2 cases osteochondroma pedicule fractures and talus posteromedial tubercle fracture due to direct trauma. Calcaneal spur and osteochondromas were removed surgically and posteromedial tubercle was treated by short-leg cast immobilization. In conclusion, we think that fractures of osteochondroma and calcaneal spur may be treated by surgical removal which do not cause any functional disorders after this operation, but fractures like the talus posteromedial tubercle should be treated conservatively by short-leg immobilization in the early period.

  14. Fracture resistance of cuspal coverage of endodontically treated maxillary premolars with combined composite-amalgam compared to other techniques.

    PubMed

    Shafiei, F; Memarpour, M; Karimi, F

    2011-01-01

    This in vitro study investigated the fracture resistance of teeth restored with combined composite-amalgam for cuspal coverage compared to direct coverage with composite (with or without an amalgam base) and composite onlay. Seventy-two intact maxillary premolars were randomly divided into six groups (n=12). The two control groups were G1, intact teeth (negative control), and G2, mesio-occlusodistal preparation only (positive control). Each of the four experimental groups used a different type of restoration for the prepared teeth: G3, direct composite cusp coverage; G4, composite onlay; G5, direct composite coverage with an amalgam base; and G6, combined composite-amalgam cuspal coverage. After thermocycling, fracture strength was tested. The data were analyzed with analysis of variance and the least significant differences post hoc tests (α=0.05). Mean fracture resistance in the six groups (in N) were G1, 1101 ±1 86; G2, 228 ± 38; G2, 699 ± 161; G4, 953 ± 185; G5, 859 ± 146; and G6, 772 ± 154. There were significant differences between G1 and all the other groups except for G4 and between G2 and all the other groups. Fracture strength in G3 also differed significantly compared to G4 and G5. The difference between G4 and G6 was statistically significant (p<0.05), but the difference between G3 and G6 was not (p>0.05).

  15. A novel method to assess primary stability of press-fit acetabular cups.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2014-11-01

    Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stability using a novel method for measuring acetabular cup micromotion. A press-fit cup was inserted into Sawbones(®) foam blocks having different densities to simulate normal and osteoporotic bone variations and different acetabular geometries. The stability of the cup was assessed in two ways: (a) measurement of micromotion of the cup in 6 degrees of freedom under physiological loading and (b) uniaxial push-out tests. The results indicate that changes in bone substrate density and acetabular geometry affect the stability of press-fit acetabular cups. They also suggest that cups implanted into weaker, for example, osteoporotic, bone are subjected to higher levels of micromotion and are therefore more prone to loosening. The decrease in stability of the cup in the physiological model suggests that using simplified spherical cavities to model the acetabulum over-estimates the initial stability of press-fit cups. This novel testing method should provide the basis for a more representative protocol for future pre-clinical evaluation of new acetabular cup designs.

  16. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  17. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  18. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  19. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip)...

  20. Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures

    PubMed Central

    Zhou, Kai-Hua; Luo, Cong-Feng; Chen, Nong; Hu, Cheng-Fang; Pan, Fu-Gen

    2016-01-01

    Background: The incidence of pelvic fractures in trauma patients is reported to be 3–8.2%, with roughly half of these fractures being caused by high energy injuries with a potential for catastrophic hemorrhage and death. Indications for internal fixation of anterior pelvic ring are controversial. Because of fears of disturbing the pelvic hematoma and causing additional hemorrhage, open reduction and internal fixation of pelvic ring disruption is routinely delayed. In contrast to conventional surgery, percutaneous screw fixation is gaining popularity in the treatment of pelvic and acetabular fractures mainly because of minimal soft tissue damage, less operative blood loss, early surgical intervention and comfortable mobilization of the patient. Fluoro-navigation is a new surgical technique in orthopedic trauma surgery. This study is to investigate clinical results of fluoro-navigation surgery in anterior pelvic ring fractures. Materials and Methods: From January 2006 to October 2011, 23 patients with anterior pelvic ring fractures were treated with percutaneous cannulated screw under fluoro-navigation. There were 14 men and 9 women, with a mean age of 40.1 years (range 25–55). According to the AO and Orthopedic Trauma Association classification, there were seven A 2.1, two A 2.2, one A 2.3, six B 1.2, one B 2.1: 1, one B 2.2, one C 1.2, two C 1.3 and two C 2.3 types of fractures. Amongst these patients, 13 had posterior pelvic ring injuries, 8 had other injuries including urethral, lumbar vertebrae fractures and femoral fractures. All patients were operated when their general condition stabilized after emergency management. The mean time from injury to percutaneous screw fixation of the anterior pelvic ring fracture was 12 days (3–15 days). All the anterior ring fractures were fixed with cannulated screws by two senior surgeons. They were familiar with the navigation system and had gained much experience in the computer-assisted percutaneous placement of

  1. Barriers to nutritional intake in patients with acute hip fracture: time to treat malnutrition as a disease and food as a medicine?

    PubMed

    Bell, Jack; Bauer, Judith; Capra, Sandra; Pulle, Chrys Ranjeev

    2013-06-01

    Inadequate energy and protein intake leads to malnutrition; a clinical disease not without consequence post acute hip fracture. Data detailing malnutrition prevalence, incidence, and intake adequacy varies widely in this patient population. The limited success of reported interventional strategies may result from poorly defined diagnostic criteria, failure to address root causes of inadequate intake, or errors associated with selection bias. This pragmatic study used a sequential, explanatory mixed methods design to identify malnutrition aetiology, prevalence, incidence, intake adequacy, and barriers to intake in a representative sample of 44 acute hip fracture patients (73% female; mean age, 81.7 ± 10.8 years). On admission, malnutrition prevalence was 52.2%. Energy and protein requirements were only met twice in 58 weighed 24 h food records. Mean daily patient energy intake was 2957 kJ (50.9 ± 36.1 kJ·kg(-1)) and mean protein intake was 22.8 g (0.6 ± 0.46 g·kg(-1)). This contributed to a further in-patient malnutrition incidence of 11%. Barriers to intake included patient perceptions that malnutrition and (or) inadequate intake were not a problem, as well as patient and clinician perceptions that treatment for malnutrition was not a priority. Malnutrition needs to be treated as a disease not without consequence, and food should be considered as a medicine after acute hip fracture.

  2. [Protrusio acetabuli. An update on the primary and secondary acetabular protrusion].

    PubMed

    Kindynis, P; Garcia, J

    1990-01-01

    Acetabular protrusion refers to intrapelvic displacement of the medial wall of the acetabulum and is defined as inward movement of the acetabular line so that the distance between this line and the laterally located ilioischial line is 3 mm or more in adult men and 6 mm or more in adult women. As discussed in this article, acetabular protrusion may be found in many bone disorders such as degenerative joint disease, Paget's disease, rheumatoid arthritis, ankylosing spondylitis, osteomalacia, Marfan's disease and as an effect of irradiation. Protrusio acetabuli appearing in absence of any recognizable cause is termed primary acetabular protrusion or Otto pelvis. Primary acetabular protrusion usually affects both hips in young to middle aged women with a history of diminished abduction, rotation and hip pain since puberty. Radiographically one notes a bilateral axial migration of the femoral head without joint space loss and with moderate degenerative changes.

  3. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    PubMed

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction.

  4. Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology.

    PubMed

    Peters, Frank M; Greeff, Richard; Goldstein, Neal; Frey, Chris T

    2012-08-01

    Acetabular cup placement in total hip arthroplasty is often difficult to assess, especially in the lateral position and using the posterior approach. Conventional techniques and computer-assisted surgery are the 2 most popular methods for proper placement of the acetabular cup in Lewinnek's safe zone of orientation (anteversion 15° ± 10° and lateral inclination 40° ± 10°). We developed a system that uses the accelerometer and camera function of the iPhone. A level indicator application and protractor application were downloaded to the iPhone and used to improve acetabular cup placement. This system has proven to be accurate and quick. Our series of 50 prospective cases showed good results with all our acetabular cups being placed within a narrow range in the safe zone and with less than 5% difference between the preoperative, intraoperative, and postoperative acetabular inclinations.

  5. Anterior Reduction, Discectomy, and Three Cortical Iliac Bone Grafting With Instrumentation to Treat A Huge Tear Drop Fracture of the Axis: A Case Report and Literature Review.

    PubMed

    Ma, Litai; Yang, Yi; Gong, Quan; Ding, Chen; Liu, Hao; Hong, Ying

    2016-04-01

    Fractures of the axis body have been little reported and treatment strategies remain controversial and individualized. Not more than 10 cases of huge tear drop fracture of the axis (HTDFA) have been reported in previous studies and the treatment method varies from conservative treatment to an anterior, or posterior, approach surgery. Considering the sparse knowledge of HTDFA, we present a special case report to share our experience and to explore the safety and effectiveness of anterior reduction and fusion to treat HTDFA. A 24-year-old man was referred to our department; he presented with neck pain lasting for 12 h since being involved in a roll-over motor vehicle accident. His neck movement was limited but there was no neurological compromise. Physical examination of the patient showed myodynamia of four limbs Grade 5, Hoffmann sign (-), and Babinski sign (-). Three-dimensional reconstruction computed tomography (CT) confirmed a huge tear drop fracture of the anterior-inferior corner of the axis and discontinuity of the cortex of the axis. After discussion with the spinal surgeon team in the department and an effective conversation with the patient, surgery involving anterior reduction, discectomy, and three cortical iliac bone grafts with instrumentation after transnasal induction of general anesthesia was performed. The patient was instructed to wear a cervical collar until he returned to our department for a follow-up examination some 3 months after surgery. The 3-month postoperative x-ray and CT scan showed a good position of the implant and bony fusion at the C2/3 segment. Anterior reduction, discectomy, and three cortical iliac bone grafts with instrumentation to treat HTDFA are effective, safe, and simple. Of course, longer follow-up duration and more cases are warranted to verify this procedure. Anterior reduction, discectomy, and bone grafting with instrumentation are warranted for most HTDFA cases. However, if HTDFA incorporates other complex

  6. Outcomes of polyethylene liner cementation into a fixed metal acetabular shell with minimum follow-up of 7 years.

    PubMed

    Park, Myung-Sik; Yoon, Sun-Jung; Lee, Ju Rang

    2015-01-01

    Cementation of a polyethylene liner into the well-fixed shell is a convenient option for revision total hip arthroplasty. We retrospectively reviewed 45 patients who had liner cementation to investigate the risk factors which gave rise to major complications and reoperation. Patients were observed for a minimum of 7 years (range 7.8-14 years). Relevant risk factors (age, BMI, surgical approach, previous cup size and position, types of coated surface) were assessed with Cox regression analysis. The mean Harris Hip Score was improved from 62.5 (range 57-68) preoperatively to 87.1 (range 70-97). A total of 7 hips (15.5%) had acetabular component loosening that was treated with reoperation. Prevalence of acetabular component loosening was statistically significantly higher in hydroxyapatite-coated group (5 of 13) than in the Ti-coated group (2 of 32, p = 0.015). All recurrent dislocations occurred in patients treated with a posterior approach. Diameter of the previous metal shell of below 54 mm showed a lower 10-year survival rate than those greater than 54 mm in diameter. PE liner cementation in stable metal cup is a useful alternative option for carefully selected patients. Pre-existing HA-coated cups as well as small sized cups were indicative of poor outcomes.

  7. The outcomes of displaced paediatric distal radius fractures treated with percutaneous Kirschner wire fixation: a review of 248 cases.

    PubMed

    Ramoutar, D N; Shivji, F S; Rodrigues, J N; Hunter, J B

    2015-04-01

    This study aimed to evaluate the effect of manipulation under anaesthesia (MUA) and Kirschner wire (K-wire) fixation of displaced, paediatric distal radius fractures on residual radiological angulation, displacement, and shortening, as well as functional outcomes, including complication rates. A retrospective review was conducted of all paediatric patients undergoing MUA and K-wire fixation for an extra-articular distal radius fracture over a period of 5 years. A total of 248 patients were included in the study with a mean age of 9.9 years (3-15). Mean follow-up was 6.6 weeks (4-156). There was a statistically significant increase in median dorsal angulation (p<0.0001) between initial post-operative and follow-up radiographs at the time of K-wire removal. The number of K-wires used did not have a significant effect on dorsal angulation (p=0.9015) at time of K-wire removal, nor did the use of an above or below elbow cast (p=0.3883). Seventeen patients required a further general anaesthetic (5 revision operations, 12 removal of migrated K-wires). Eighty-seven percentage of (215 patients) of patients had normal function at follow-up post-K-wire removal. Angulation at time of K-wire removal of more than 15° was significantly associated with reduced functional outcome (p=0.0377). A total of 41 patients (17%) had complications associated with K-wire use. We conclude that though K-wire fixation is an effective technique, it does not prevent re-angulation of the fracture and is associated with a significant complication rate. Given the remodelling potential and tolerance to deformity in children, surgeons should give careful thought before utilising this technique for all displaced or angulated paediatric distal radius fractures. If used, 1 K-wire with immobilisation in a below elbow cast is sufficient in most cases.

  8. The four-year functional result after a displaced subcapital hip fracture treated with three different surgical options.

    PubMed

    Mouzopoulos, George; Stamatakos, Michalis; Arabatzi, Helen; Vasiliadis, George; Batanis, George; Tsembeli, Anastasia; Tzurbakis, Mathaios; Safioleas, Michalis

    2008-06-01

    According to the literature, hip function after hip fracture is affected by the type of surgery. Our aim was to determine the correlation between surgical treatment of hip fracture and postoperative function in the elderly. Inclusion criteria were displaced hip fracture and age over 70 years. One hundred and twenty-nine participants were randomly divided into three groups according to the type of the surgical operation they underwent (hemi-arthroplasty [Merete, Berlin, Germany], total arthroplasty [Plus; De Puy, Warsaw, IN, USA] and internal fixation [Richards plate screw; Smith & Nephew, Memphis, TN, USA]). The function of the patients was estimated using the following parameters: the Barthel Index and Harris Hip Score, the range of passive hip motion, the gait speed of individuals, after 1 and 4 years of follow-up. The Barthel Index scores after 4 years of follow-up were 85.3, 82.6, 80.1 after total arthroplasty, hemi-arthroplasty and internal fixation respectively. Similarly, the Harris Hip Scores after 4 years of follow-up were 83.7, 79.5 and 73.6. The range of passive hip motion in the three groups of patients did not differ significantly (p>0.05). Also, patients of the total arthroplasty and hemi-arthroplasty groups walked faster than the patients of the internal fixation group 4 years after discharge (p<0.05). In conclusion, we believe that total hip arthroplasty is the treatment of choice for displaced subcapital hip fractures in patients over 70 years old.

  9. Three-dimensional acetabular orientation measurement in a reliable coordinate system among one hundred Chinese

    PubMed Central

    Zhang, Henghui; Wang, Yiping; Ai, Songtao; Chen, Xiaojun; Wang, Liao; Dai, Kerong

    2017-01-01

    Determining three-dimensional (3D) acetabular orientation is important for several orthopaedic scenarios, but the complex geometries of both pelvis and acetabulum make measurements of orientation unreliable. Acetabular orientation may also differ between the sexes or racial groups. We aimed to (1) establish and evaluate a novel method for measuring 3D acetabular orientation, (2) apply this new method to a large population of Chinese subjects, and (3) report relevant characteristics of native acetabular orientation in this population. We obtained computed tomography scans taken for non-orthopaedic indications in 100 Chinese subjects (50 male, 50 female). A novel algorithm tailored to segmentation of the hip joint was used to construct 3D pelvic models from these scans. We developed a surface-based method to establish a reliable 3D pelvic coordinate system and software to semi-automatically measure 3D acetabular orientation. Differences in various acetabular orientations were compared within and between subjects, between male and female subjects, and between our subjects and subjects previously reported by another group. The reported method was reliable (intraclass correlation coefficient >0.999). Acetabular orientations were symmetrical within subjects, but ranged widely between subjects. The sexes differed significantly in acetabular anteversion (average difference, 3.0°; p < 0.001) and inclination (1.5°; p < 0.03). Acetabular anteversion and inclination were substantially smaller among our Chinese subjects than previously reported for American subjects. Thus, our method was reliable and sensitive, and we detected sex differences in 3D acetabular orientation. Awareness of differences between the sexes and races is the first step towards better reconstruction of the hip joint for all individuals and could also be applied to other orthopaedic scenarios. PMID:28207829

  10. Changes in the radiological measurements of the tibiofibular syndesmal area in patients with Weber C ankle fractures who were treated with open reduction, internal fixation, and transyndesmal screw.

    PubMed

    Jasqui-Remba, S; Torres-Gómez, A; Salas-Morales, G A; Hernández-Martínez, A

    2015-01-01

    The tibiofibular syndesmosis provides stability to the ankle mortise. The ankle syndesmosis is compromised in all Weber C type injuries. The radiographic method described by Merle DAubigné considers the bony relationships as a measure of syndesmotic widening. We sought to investigate whether the patients with a C type ankle fracture treated with ORIF and placement of a transyndesmal screw have an increment of the tibiofibular space and decrease of the tibiofibular overlap after the transyndesmal screw is removed. Our sample included 52 patients with Weber C ankle fractures treated by ORIF and transyndesmal screw at a level II trauma center. We measured the tibiofibular clear space and tibiofibular overlap in each phase of the treatment. The transyndesmal screw was removed at day 55.56 (± 21.83). We found an increase of the tibiofibular overlap of 0.20 mm (± 2.29, p = 0.532); and 0.21 mm (± 0.97, p = 0.146) in the tibiofibular clear space. The changes of 2.38% in the tibiofibular overlap and 5.29% in the tibiofibular clear space between the postoperative and post-removal periods were not statistically significant. After removal of the syndesmal screw, there is a slight radiographic broadening of the syndesmosis; however, it is small and statistically not significant.

  11. Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth

    PubMed Central

    Bechara, B; McMahan, C A; Noujeim, M; Faddoul, T; Moore, W S; Teixeira, F B; Geha, H

    2013-01-01

    Objectives: Two-dimensional intraoral radiography is the most common tool for diagnosing root fractures (RFs). Cone beam CT (CBCT) is widely used to depict RFs in endodontically treated teeth. Beam hardening and other artefacts caused by gutta percha may result in an incorrect diagnosis when using CBCT only. A comparison of two CBCT machines with photostimulated phosphor (PSP) plate images enhanced with the equalization tool was carried out to detect RFs in endodontically treated teeth. Methods: 66 roots were collected, decoronated and treated endodontically using the same technique with gutta percha. 33 of these roots were randomly selected and fractured; the 2 root fragments were glued together with 1 layer of methyl methacrylate and placed randomly in 8 prepared beef rib fragments. Large fields of view (FOVs) were acquired with one CBCT unit and small FOVs with the second CBCT unit. Periapical radiographs (using intraoral PSP plates) were also acquired. A contrast enhancement tool was used when evaluating the PSP plate images. Results: Small FOV images had significantly higher accuracy (area under the receiver operating characteristic curve) and sensitivity in detecting RFs than PSP plates and large FOV images. The specificity of the enhanced PSP images was higher than, although not significantly higher than, the small FOV images and was significantly higher than the large FOV images. Conclusions: CBCT small FOVs should be acquired for depicting RFs of endodontically treated teeth. Images obtained using PSP plates had the lowest rate of false-positive results and their use can save the patient a radiation dose. PMID:23625067

  12. Incidence and clinical relevance of tibiofibular synostosis in fractures of the ankle which have been treated surgically.

    PubMed

    Droog, R; Verhage, S M; Hoogendoorn, J M

    2015-07-01

    In this retrospective cohort study, we analysed the incidence and functional outcome of a distal tibiofibular synostosis. Patients with an isolated AO type 44-B or C fracture of the ankle who underwent surgical treatment between 1995 and 2007 were invited for clinical and radiological review. The American Orthopaedic Foot and Ankle Society score, the American Academy of Orthopaedic Surgeons score and a visual analogue score for pain were used to assess outcome. A total of 274 patients were available; the mean follow-up was 9.7 years (8 to 18). The extent of any calcification or synostosis at the level of the distal interosseous membrane or syndesmosis on the contemporary radiographs was defined as: no or minor calcifications (group 1), severe calcification (group 2), or complete synostosis (group 3). A total of 222 (81%) patients were in group 1, 37 (14%) in group 2 and 15 (5%) in group 3. There was no significant difference in incidence between AO type 44-B and type 44-C fractures (p = 0.89). Severe calcification or synostosis occurred in 21 patients (19%) in whom a syndesmotic screw was used and in 31 (19%) in whom a syndesmotic screw was not used.(p = 0.70). No significant differences were found between the groups except for a greater reduction in mean dorsiflexion in group 2 (p = 0.004). This is the largest study on distal tibiofibular synostosis, and we found that a synostosis is a frequent complication of surgery for a fracture of the ankle. Although it theoretically impairs the range of movement of the ankle, it did not affect the outcome. Our findings suggest that synostosis of the distal tibiofibular syndesmosis in general does not warrant treatment.

  13. Early changes in bone density, microarchitecture, bone resorption, and inflammation predict the clinical outcome 12 weeks after conservatively treated distal radius fractures: an exploratory study.

    PubMed

    Meyer, Ursina; de Jong, Joost J; Bours, Sandrine G P; Keszei, András P; Arts, Jacobus J; Brink, Peter R G; Menheere, Paul; van Geel, Tineke A C M; van Rietbergen, Bert; van den Bergh, Joop P W; Geusens, Piet P; Willems, Paul C

    2014-09-01

    Fracture healing is an active process with early changes in bone and inflammation. We performed an exploratory study evaluating the association between early changes in densitometric, structural, biomechanical, and biochemical bone parameters during the first weeks of fracture healing and wrist-specific pain and disability at 12 weeks in postmenopausal women with a conservatively treated distal radius fracture. Eighteen patients (aged 64 ± 8 years) were evaluated at 1 to 2 and 3 to 4 weeks postfracture, using high-resolution peripheral quantitative computed tomography (HR-pQCT), micro-finite element analysis, serum procollagen type-I N-terminal propeptide (P1NP), carboxy-terminal telopeptide of type I collagen (ICTP), and high-sensitive C-reactive protein (hsCRP). After 12 weeks, patients rated their pain and disability using Patient Rated Wrist Evaluation (PRWE) questionnaire. Additionally, Quick Disability of the Arm Shoulder and Hand (QuickDASH) questionnaire and active wrist range of motion was evaluated. Linear regression models were used to study the relationship between changes in bone parameters and in hsCRP from visit 1 to 2 and PRWE score after 12 weeks. A lower PRWE outcome, indicating better outcome, was significantly related to an early increase in trabecular bone mineral density (BMD) (β -0.96 [95% CI -1.75 to -0.16], R(2)  = 0.37), in torsional stiffness (-0.14 [-0.28 to -0.004], R(2)  = 0.31), and to an early decrease in trabecular separation (209 [15 to 402], R(2)  = 0.33) and in ICTP (12.1 [0.0 to 24.1], R(2)  = 0.34). Similar results were found for QuickDASH. Higher total dorsal and palmar flexion range of motion was significantly related to early increase in hsCRP (9.62 [3.90 to 15.34], R(2)  = 0.52). This exploratory study indicates that the assessment of early changes in trabecular BMD, trabecular separation, calculated torsional stiffness, bone resorption marker ICTP, and hsCRP after a distal radius fracture provides

  14. Assessment of the influence of Laser phototherapy on the bone repair process of complete fractures in tibiae of rabbits stabilized with semi-rigid internal fixation treated with or without MTA graft: a histological study

    NASA Astrophysics Data System (ADS)

    Soares, Luiz G. P.; Silva, Aline C. P.; Silva, Anna Paula L. T.; Neves, Bruno Luiz R. C.; Santos, Nicole R. S.; dos Santos, Jean N.; Pinheiro, Antonio L. B.

    2016-03-01

    Beside biomaterials, Laser phototherapy has shown positive effects as auxiliary therapy in bone repair process, especially when involving large bone losses. The aim of this histological study was to evaluate, by light microscopy, the influence of laser phototherapy on the repair of complete tibial fractures in rabbits treated or not with semi-rigid internal fixation and Mineral Trioxide Aggregate - MTA graft. Twelve Rabbits were randomly divided into four groups with three animals each. After general anesthesia, complete fractures were created in one tibia with a carborundum disk. All animals (groups I-IV) had the fracture stabilized with semi-rigid fixation (wire osteosynthesis - WO). Group I was routinely fixed with WO; groups II and IV fracture was filled by blood clot and MTA implant. In Groups III and IV fracture was filled by blood clot and further irradiated with laser (λ780 nm, 70 mW, CW, Φ = 0.04 cm2, 20.4 J/cm2, per session, t = 300s, 142.8 J/cm2 per treatment). The phototherapy protocol was applied immediately after the surgery and repeated each 48 hours during 15 days. Animal death occurred on the 30th postoperative day. After removal of the specimens, the samples were routinely processed, stained with HE and evaluated by light microscopy. Histologically, the group treated with MTA graft and irradiated with laser showed the fracture filled by a more organized and mature trabecular bone, when compared with all other groups. From the results of the present study, it may be concluded that the association of Laser phototherapy + MTA graft in fractures treated with WO improved bone repair when compared with fractures treated only with WO.

  15. [Fractures of the forefoot].

    PubMed

    Richter, M

    2011-10-01

    Fractures of the forefoot are common and comprise approximately two thirds of all foot fractures. Forefoot fractures are caused by direct impact or the effect of indirect force. The forces exerted can range from repetitive minor load (stress fractures) to massive destructive forces (complex trauma). The clinical course in forefoot fractures is typically more favourable than in fractures of the mid- and hindfoot. The incidence of complications like infection or pseudarthrosis is low. Exceptions are rare fractures of the proximal shaft of the fifth metatarsal and the sesamoids with higher pseudarthrosis rates. Malunited metatarsal fractures can cause painful conditions that should even be treated operatively. Differences in structure and function of the different forefoot areas and specific fracture types require an adapted management of these special injuries.

  16. Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis

    PubMed Central

    Kang, He-Kyong; Chu, Tien-Min; Dechow, Paul; Stewart, Kelton; Kyung, Hee-Moon

    2016-01-01

    Summary Background/Objectives: This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). Material and Methods: Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group received Nd-YAG laser surface treatment. Half in each group was used for examining surface roughness (Sa and Sq), surface texture, and facture resistance. The remaining MSIs were placed in the maxilla of six skeletally mature male beagle dogs in a randomized split-mouth design. A pair with the same surface treatment was placed on the same side and immediately loaded with 200g nickel–titanium coil springs for 8 weeks. After killing, the bone-implant contact (BIC) for each MSI was calculated using micro computed tomography. Analysis of variance model and two-sample t test were used for statistical analysis with a significance level of P <0.05. Results: The mean values of Sa and Sq were significantly higher in the laser-treated group compared with the machined group (P <0.05). There were no significant differences in fracture resistance and BIC between the two groups. Limitation: animal study Conclusions/Implications: Laser treatment increased surface roughness without compromising fracture resistance. Despite increasing surface roughness, laser treatment did not improve BIC. Overall, it appears that medical grade SS has the potential to be substituted for titanium alloy MSIs. PMID:25908868

  17. A comparison of fracture resistance of endodontically treated teeth restored with bonded partial restorations and full-coverage porcelain-fused-to-metal crowns.

    PubMed

    Gupta, Abhishek; Musani, Smita; Dugal, Ramandeep; Jain, Nikhil; Railkar, Bhargavi; Mootha, Ajay

    2014-01-01

    The aim of this study was to evaluate the use of bonded partial restorations compared with full-coverage porcelain-fused-to-metal (PFM) crowns as a viable treatment option for endodontically treated posterior teeth. Forty-five recently extracted maxillary first premolars were collected, endodontically treated, and mounted in acrylic blocks. The specimens were randomly divided into three groups and prepared to receive their respective restorations. The teeth in group 1 received full-coverage porcelain-fused-to-metal crowns. The teeth in group 2 received bonded partial restorations made from pressed ceramics (lithium disilicate) involving a functional cusp (palatal). Finally, group 3 received bonded partial restorations made from pressed ceramics involving the buccal cusp and keeping a functional cusp (palatal) intact. All group 1 restorations were cemented using glass ionomer cement. Restorations in groups 2 and 3 were bonded using a dual-cured resin cement. All specimens were subjected to an aging process and tested for shear bond strength using a universal loading machine. The mean force applied in Newtons to cause failure for group I was 674.90 ± 94.16 N, for group 2, 463.46 ± 61.11 N, and for group 3, 849.33 ± 68.92 N. P values obtained using one-way analysis of variance showed a highly significant difference between groups 2 and 3 (P = .001), groups 1 and 2 (P = .001), and groups 1 and 3 (P = .001). The fracture modes observed in all groups involved restorations and tooth fracture. This in vitro study suggests that endodontically treated posterior teeth with intact functional cusps can be restored with bonded partial porcelain restorations. However, if the loss of tooth structure involves the functional cusp, full-coverage PFM crowns are the treatment of choice.

  18. Automated measurement of anterior and posterior acetabular sector angles

    NASA Astrophysics Data System (ADS)

    Ibragimov, Bulat; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2012-03-01

    In this paper, we propose a segmentation algorithm by which anatomical landmarks on the pelvis are extracted from computed tomography (CT) images. The landmarks are used to automatically define the anterior (AASA) and posterior acetabular sector angles (PASA) describing the degree of hip misalignment. The center of each femoral head is obtained by searching for the point at which most intensity gradient vectors defined at edge points intersect. The radius of each femoral head is computed by finding the sphere, positioned at the center of the femoral head, for which the normalized sum of gradient vector magnitudes on the sphere surface is maximal. The anterior and posterior corners of each acetabulum are searched for on a curve representing the acetabulum and defined by dynamic programming. The femoral head centers and anterior and posterior corners are used to calculate the AASA and PASA. The algorithm was applied to CT images of 120 normal subjects and the results were compared to ground truth values obtained by manual segmentation. The mean absolute difference (+/- standard deviation) between the obtained and ground truth values was 1.3 +/- 0.3 mm for the femoral head centers and 2.1 +/- 1.3 degrees for the acetabular angles.

  19. Comparison of flanged and unflanged acetabular cup design

    PubMed Central

    2010-01-01

    Background and purpose Adequate depth of cement penetration and cement mantle thickness is important for the durability of cemented cups. A flanged cup, as opposed to unflanged, has been suggested to give a more uniform cement mantle and superior cement pressurization, thus improving the depth of cement penetration. This hypothesis was tested experimentally. Materials and methods The same cup design with and without flange (both without cement spacers) was investigated regarding intraacetabular pressure, cement mantle thickness, and depth of cement penetration. With machine control, the cups were inserted into open-pore ceramic acetabular models (10 flanged, 10 unflanged) and into paired cadaver acetabuli (10 flanged, 10 unflanged) with prior pressurization of the cement. Results No differences in intraacetabular pressures during cup insertion were found, but unflanged cups tended to migrate more towards the acetabular pole. Flanged cups resulted in thicker cement mantles because of less bottoming out, whereas no differences in cement penetration into the bone were observed. Interpretation Flanged cups do not generate higher cementation pressure or better cement penetration than unflanged cups. A possible advantage of the flange, however, may be to protect the cup from bottoming out, and there is possibly better closure of the periphery around the cup, sealing off the cement-bone interface. PMID:20860522

  20. Total arthroplasty in displaced dysplastic hips with acetabular reconstruction and femoral shortening - technical note.

    PubMed

    Silva, Paulo; de Oliveira, Leandro Alves; Coelho, Danilo Lopes; do Amaral, Rogério Andrade; Rebello, Percival Rosa; de Moraes, Frederico Barra

    2014-01-01

    To describe a new procedure of total hip replacement in patient with severe developmental dysplasia of the left hip, using technique of acetabular reconstruction with autogenous bone grafts and subtrochanteric shortening femoral osteotomy. Total hip replacement done in January of 2003. The Eftekhar's classification was used and included type D, neglected dislocations. Bone graft incorporated in acetabular shelf and femoral osteotomy. Our contribution is the use of an Allis plate to better fix acetabular grafts, avoiding loosening, and cerclage around bone graft in femoral osteotomy site, which diminish pseudoarthrosis risk. This technique shows efficiency, allowing immediately resolution for this case with pain and range of motion of hip improvement. It also allows the acetabular dysplasia reconstruction, equalization of the limb length (without elevated risk of neurovascular lesion) and repairs the normal hip biomechanics due to the correction of the hip's center of rotation.

  1. A simplified method to determine acetabular cup anteversion from plain radiographs.

    PubMed

    Widmer, Karl-Heinz

    2004-04-01

    Plain radiographs are the most important diagnostic means for determining the indication and following up on total hip arthroplasty. The acetabular cup position can be easily determined by applying trigonometric functions. This report presents an even simpler method. The short axis of the projected ellipse is measured and related to the total cross-section of the projected cup along the short axis. This relationship correlates with acetabular cup anteversion angles and represents an inverse sinus function. A close linear correlation is seen within the most common interval from 10 degrees to 30 degrees. Anteversion is between 23 degrees to 24 degrees when the ellipse bisects the total acetabular cross-section. This means that simply measuring the length of the short ellipse axis and the total length of the projected cross-section along the short axis provides the radiographic acetabular anteversion. Nonorthogonal projected radiographs should be corrected first.

  2. Fixed-angle screws vs standard screws in acetabular prosthesis fixation: a cadaveric biomechanical study.

    PubMed

    Hugate, Ronald R; Dickey, Ian D; Chen, Qingshan; Wood, Christina M; Sim, Franklin H; Rock, Michael G

    2009-08-01

    Secure fixation of acetabular components in total hip arthroplasty can be challenging. The purpose of this study was to perform biomechanical analysis of cup fixation strength using fixed-angle vs standard screw fixation. Multihole, porous-backed acetabular prostheses were implanted in both acetabuli of 8 cadaveric pelves using standard press-fit techniques. Fixed-angle screws were used on the left side, and standard cancellous screws were used in the right. The use of fixed-angle screws enhanced acetabular fixation substantially under subfailure cyclic loading conditions and load-to-failure. The triradiate screw configuration increases the bending moment required to fail the specimens as well. Fixed-angle screws may be useful for achieving rigid fixation of acetabular prostheses in challenging clinical scenarios.

  3. Revisions of Extensive Acetabular Defects with Impaction Grafting and a Cement Cup

    PubMed Central

    van Egmond, Nienke; De Kam, Daniel C. J.; Gardeniers, Jean W. M.

    2010-01-01

    Background Loosening of acetabular components often leads to bony defects. Management of extensive acetabular bone loss in hip revision arthroplasty can be a tremendous challenge. Questions/purposes We asked whether a reconstruction with impacted bone grafts will provide a durable and pain-free function in extensive acetabular defects. We specifically determined the (1) survival rates with the end point of revision for any reason, aseptic revision, and radiographic loosening; (2) visual analog scale (VAS) pain score, Harris hip score (HHS), and the Oxford Hip Questionnaire score (OHQS); (3) number of repeat revisions; (4) complications; and (5) radiographic loosening, wear, and radiolucencies. Patients and Methods We retrospectively followed 25 patients (27 hips) with extensive acetabular defects. No patient was lost to followup. Two patients died during followup. Minimum followup was 3 years (mean, 8.8 years; range, 3–14.1 years). Results Three patients (three hips) underwent repeat revision surgery and another two patients (two hips) had radiographically loose hips. The 10-year survival rate was 88% (95% confidence interval, 74.2%–100%) with the end point acetabular revision for any reason and 95% (95% confidence interval, 86.0%–100%) with the end point acetabular revision for aseptic loosening. The mean HHSs were 55 points before surgery and 72 points postoperatively. Conclusions Acetabular reconstruction with impaction bone grafting and a cemented cup is a reliable technique with a 10-year survival rate of 88% in patients with extensive acetabular deficiencies. Level of Evidence Level IV, case series. See the Guidelines for Authors for a complete description of levels of evidence. PMID:20931308

  4. Acetabular cartilage defects cause altered hip and knee joint coordination variability during gait

    PubMed Central

    Samaan, Michael A.; Teng, Hsiang-Ling; Kumar, Deepak; Lee, Sonia; Link, Thomas; Majumdar, Sharmila; Souza, Richard B.

    2015-01-01

    Background Patients with acetabular cartilage defects reported increased pain and disability compared to those without acetabular cartilage defects. The specific effects of acetabular cartilage defects on lower extremity coordination patterns are unclear. The purpose of this study was to determine hip and knee joint coordination variability during gait in those with and without acetabular cartilage defects. Methods A combined approach, consisting of a semi-quantitative MRI-based quantification method and vector coding, was used to assess hip and knee joint coordination variability during gait in those with and without acetabular cartilage lesions. Findings The coordination variability of the hip flexion-extension/knee rotation, hip abduction-adduction/knee rotation and hip rotation/knee rotation joint couplings were reduced in the acetabular lesion group compared to the control group during loading response of the gait cycle. The lesion group demonstrated increased variability in the hip flexion-extension/knee rotation and hip abduction-adduction/knee rotation joint couplings, compared to the control group, during the terminal stance/pre-swing phase of gait. Interpretation Reduced variability during loading response in the lesion group may suggest reduced movement strategies and a possible compensation mechanism for lower extremity instability during this phase of the gait cycle. During terminal stance/pre-swing, a larger variability in the lesion group may suggest increased movement strategies and represent a compensation or pain avoidance mechanism caused by the load applied to the hip joint. PMID:26298706

  5. Mechanical resistance evaluation of a novel anatomical short glass fiber reinforced post in artificial endodontically treated premolar under rotational/lateral fracture fatigue testing.

    PubMed

    Wang, Hsuan-Wen; Chang, Yen-Hsiang; Lin, Chun-Li

    2016-01-01

    This study develops a novel anatomical short glass fiber reinforced (anatomical SGFR) post and evaluates the mechanical performance in artificial endodontically treated premolars. An anatomical SGFR fiber post with an oval shape and slot/notch designs was manufactured using an injection-molding machine. The three-point bending test and crown/core restorations using the anatomical SGFR and commercial cylindrical fiber posts under fatigue test were executed to understand the mechanical resistances. The results showed that static and dynamic rotational resistance were found significantly higher in the anatomical SGFR fiber post than in the commercial post. The endurance limitations at 1.2×10(6) cycles were 66.81 and 64.77 N for the anatomical SGFR and commercial fiber posts, respectively. The anatomical SGFR fiber post presented acceptable value of flexural strength and modulus, better fit adaption in the root canal resist torque more efficiency but was not a key issue in the lateral fracture resistance in an endodontically treated premolar.

  6. Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study

    PubMed Central

    Michel, Adrien; Bosc, Romain; Meningaud, Jean-Paul; Hernigou, Philippe; Haiat, Guillaume

    2016-01-01

    Background The primary stability of the acetabular cup (AC) implant is an important determinant for the long term success of cementless hip surgery. However, it remains difficult to assess the AC implant stability due to the complex nature of the bone-implant interface. A compromise should be found when inserting the AC implant in order to obtain a sufficient implant stability without risking bone fracture. The aim of this study is to evaluate the potential of impact signals analyses to assess the primary stability of AC implants inserted in cadaveric specimens. Methods AC implants with various sizes were inserted in 12 cadaveric hips following the same protocol as the one employed in the clinic, leading to 86 different configurations. A hammer instrumented with a piezoelectric force sensor was then used to measure the variation of the force as a function of time produced during the impact between the hammer and the ancillary. Then, an indicator I was determined for each impact based on the impact momentum. For each configuration, twelve impacts were realized with the hammer, the value of the maximum amplitude being comprised between 2500 and 4500 N, which allows to determine an averaged value IM of the indicator for each configuration. The pull-out force F was measured using a tangential pull-out biomechanical test. Results A significant correlation (R2 = 0.69) was found between IM and F when pooling all data, which indicates that information related to the AC implant biomechanical stability can be retrieved from the analysis of impact signals obtained in cadavers. Conclusion These results open new paths in the development of a medical device that could be used in the future in the operative room to help orthopedic surgeons adapt the surgical protocol in a patient specific manner. PMID:27893757

  7. Quantitative Computerized Assessment of the Degree of Acetabular Bone Deficiency: Total radial Acetabular Bone Loss (TrABL)

    PubMed Central

    Gelaude, Frederik; Clijmans, Tim; Delport, Hendrik

    2011-01-01

    A novel quantitative, computerized, and, therefore, highly objective method is presented to assess the degree of total radical acetabular bone loss. The method, which is abbreviated to “TrABL”, makes use of advanced 3D CT-based image processing and effective 3D anatomical reconstruction methodology. The output data consist of a ratio and a graph, which can both be used for direct comparison between specimens. A first dataset of twelve highly deficient hemipelves, mainly Paprosky types IIIB, is used as illustration. Although generalization of the findings will require further investigation on a larger population, it can be assumed that the presented method has the potential to facilitate the preoperative use of existing classifications and related decision schemes for treatment selection in complex revision cases. PMID:22013539

  8. Comparative evaluation of the effect of different crown ferrule designs on the fracture resistance of endodontically treated mandibular premolars restored with fiber posts, composite cores, and crowns: An ex-vivo study

    PubMed Central

    Dua, Nikita; Kumar, Bhupendra; Arunagiri, D.; Iqbal, Mohammad; Pushpa, S.; Hussain, Juhi

    2016-01-01

    Introduction: In cases of severe hard tissue loss, 2 mm circumferential ferrule is difficult to achieve which leads to incorporation of different ferrule designs. Aim: To compare and evaluate the effect of different crown ferrule designs on the fracture resistance of mandibular premolars restored with fiber posts, composite cores, and crowns. Materials and Methods: Fifty freshly extracted mandibular premolars were endodontically treated and divided into five groups: Group I - 2 mm circumferential ferrule above the cementoenamel junction (CEJ); Group II - 2 mm ferrule on the facial aspect above CEJ; Group III - 2 mm ferrule on the lingual aspect above CEJ; Group IV - 2 mm ferrule on the facial and lingual aspects above CEJ with interproximal concavities, and Group V - no ferrule (control group) and were later restored with fiber posts, composite cores, and crowns. Specimens were mounted on a universal testing machine, and compressive load was applied at a crosshead speed of 1 mm/min until fracture occurred. Results: The results showed that circumferential ferrule produced the highest mean fracture resistance and the least fracture resistance was found in the control group. Conclusion: Circumferential ferrule increases the fracture resistance of endodontically treated teeth restored with bonded post, core, and crown. PMID:27217642

  9. [Epidemiology of hip fracture].

    PubMed

    Hagino, Hiroshi

    2006-12-01

    Age- and gender-specific numbers of patients with hip fracture increase with age and peaked at the age 80-84; however, age- and gender-specific incidences increase exponentially with age. According to the recent nation-wide survey, the most common cause of hip fractures was a simple fall, 68.8% sustained fractures in-doors, and the incidences were higher in the winter than the summer period. More than 90% of patients with hip fracture were treated surgically and about 3/4 of patients with femoral neck fractures were treated with hemi-arthroplasty. Hip fractures for Asian people including Japanese are lower than those for Caucasians living in Northern Europe and North America; however, recent reports from the Asian area indicated an increase in the incidence with time.

  10. Cementless modular hip arthroplasty as a salvage operation for failed internal fixation of trochanteric fractures in elderly patients.

    PubMed

    Laffosse, Jean-Michel; Molinier, François; Tricoire, Jean-Louis; Bonnevialle, Nicolas; Chiron, Philippe; Puget, Jean

    2007-12-01

    Failure of internal fixation of trochanteric fractures requires repeat surgery in order to avoid the risks of complications affecting bedridden patients. This study was conducted to assess the results of hemi- or total hip arthroplasty with a cementless modular femoral stem, as a salvage operation following early mechanical failure of internal fixation. Twenty nine patients with a mean age of 81.1 years (70-91) were included in the study. Fractures extending into the diaphysis and pathological fractures were excluded, as well as patients who presented late complications. A cementless modular stem designed for metaphyso-diaphyseal anchorage was used in all cases. Twenty-two patients underwent hemiarthroplasty and seven total hip arthroplasty. Four patients died within one year and two were lost to follow-up. The remaining 23 patients were followed for a mean of 20 months (range: 6-89). At the time of last follow-up, 20 were ambulatory with (11 cases) or without support (9 cases) and three were bedridden. There were no intra- or postoperative femoral fractures. Two patients presented an early dislocation after bipolar hemiarthroplasty. One was successfully treated by closed reduction; the other underwent revision with a dual mobility acetabular component because of recurrent dislocation. All the patients reported significant pain relief and functional improvement. Subsidence of the stem greater than 5 mm was noted in three cases, without clinical consequences. The cementless modular femoral stem used in this study appeared as a reliable implant. Primary arthroplasty with such an implant could be considered in selected cases such as markedly unstable fractures and in osteoporotic elderly patients.

  11. Atraumatic sternum fracture

    PubMed Central

    Abrahamsen, Sebastian Ørskov; Madsen, Christina Friis

    2014-01-01

    The spine, pelvic bones and long bones of the lower extremities are common sites for insufficiency fractures. Cases of sternum insufficiency fractures have rarely been reported among elderly patients. Insufficiency fractures tend to occur in bones with decreased mechanical strength especially among elderly patients, in postmenopausal women and patients with underlying diseases. We describe a case of spontaneous sternum insufficiency fracture in a healthy man, with no known risk factors to fracture, or previous history of fractures. Sternum insufficiency fracture is a rare cause of chest pain. This case serves to remind the emergency physician to remain vigilant for other non-cardiac, non-pulmonary and non-traumatic causes of chest pain, especially among patients with known risk factors such as osteoporosis, chronic obstructive pulmonary disease, rheumatoid arthritis, systemic lupus erythematosus and patients on long-term steroid treatment. If diagnosed correctly, these patients can be discharged and treated as outpatients as this case emphasises. PMID:25326566

  12. [Nasal fractures in adults].

    PubMed

    Sjöstedt, Sannia; Larsen, Christian Grønhøj; Bilde, Anders; von Buchwald, Christian

    2016-03-07

    The risk of complications warrants treatment of most dislocated nasal fractures. Other injuries including other facial fractures and septal haematoma must be treated if present at the initial presentation. The usual treatment for a simple nasal fracture is closed reduction in local anaesthesia after five to seven days. Complicated cases require open reduction in general anaesthesia. Later revision of the deviated nose may become necessary in patients suffering from complications such as persistent nasal stenosis and/or deformity.

  13. Pediatric Hand Fractures

    PubMed Central

    Nellans, Kate W.; Chung, Kevin C.

    2014-01-01

    Summary Pediatric hand fractures are common childhood injuries. Identification of the fractures in the emergency room setting can be challenging owing to the physes and incomplete ossification of the carpus that are not revealed in the xrays. Most simple fractures can be treated with appropriate immobilization through buddy taping, finger splints, or casting. If correctly diagnosed, reduced and immobilized, these fractures usually result in excellent clinical outcomes. However, fractures may require operative stabilization if they have substantial angulation or rotation, extend into the joint, or cannot be held in a reduced position with splinting alone. Most fractures can be treated operatively with closed reduction and percutaneous pinning if addressed within the first week following the injury. In children, the thick, vascular-rich periosteum and bony remodeling potential make anatomic reductions and internal fixation rarely necessary. Most fractures complete bony healing in 3-4 weeks, with the scaphoid being a notable exception. Following immobilization, children rarely develop hand stiffness and formal occupational therapy is usually not necessary. Despite the high potential for excellent outcomes in pediatric hand fractures, some fractures remain difficult to diagnose and treat. PMID:24209954

  14. Femoral Version, Neck-Shaft Angle, and Acetabular Anteversion in Chinese Han Population

    PubMed Central

    Jiang, Nan; Peng, Lin; Al-Qwbani, Mohammed; Xie, Guo-Ping; Yang, Qin-Meng; Chai, Yu; Zhang, Qing; Yu, Bin

    2015-01-01

    Abstract Anatomic data regarding femoral version, neck-shaft angle, and acetabular anteversion are still limited in Chinese Han adult population. The aim of this study was to investigate the effects of age, sex, and body laterality on the 3 important anatomic indicators in Chinese Han healthy adults. Measurements were performed independently by 3 experienced observers using the picture archiving and communication system (PACS) in healthy adults who had received imaging tests of the femur and acetabulum between January 2009 and October 2014. Relevant data were measured and analyzed. A total of 466 adults (353 males and 113 females) were included. The mean femoral version, neck-shaft angle, and acetabular anteversion for all were 10.62, 133.02, and18.79, respectively. Age-based analysis showed that adults younger than 60 years had a significantly higher neck-shaft angle (P < 0.001) but a significantly lower acetabular anteversion (P < 0.001) than those older than 60 years. Sex-based analysis revealed that females had significantly higher values of femoral version (P < 0.001) and acetabular anteversion (P < 0.001) than males. Laterality-based analysis found the left side had a significantly lower acetabular anteversion (P < 0.001) than the right side. Outcomes of multiple linear regression analysis indicated that femoral version may be associated with sex (P < 0.001) but not age (P = 0.076) or laterality (P = 0.430), neck-shaft angle may be associated with age (P < 0.001) but not sex (P = 0.378) or laterality (P = 0.233), and acetabular anteversion may be associated with age (P < 0.001) and sex (P < 0.001) but not laterality (P = 0.060). In this representative Chinese cohort, neck-shaft angle may decrease, whereas acetabular anteversion may increase with age, females may have higher values of femoral version and acetabular anteversion than males, and the right body side may have a higher value of acetabular

  15. Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum

    PubMed Central

    He, Jiliang; Tan, Guoqing; Zhou, Dongsheng; Sun, Liang; Li, Qinghu; Yang, Yongliang; Liu, Ping

    2016-01-01

    Abstract Percutaneous screw insertion for minimally displaced or reducible acetabular fracture using x-ray fluoroscopy and computer-assisted navigation system has been advocated by some authors. The purpose of this study was to compare intraoperative conditions and clinical results between isocentric C-arm 3-dimensional (Iso-C 3D) fluoroscopy and conventional fluoroscopy for percutaneous retrograde screwing of acetabular anterior column fracture. A prospective cohort study was conducted. A total of 22 patients were assigned to 2 different groups: 10 patients in the Iso-C 3D navigation group and 12 patients in the conventional group. The operative time, fluoroscopic time, time of screw insertion, blood loss, and accuracy were analyzed between the 2 groups. There were significant differences in operative time, screw insertion time, fluoroscopy time, and mean blood loss between the 2 groups. Totally 2 of 12 (16.7%) screws were misplaced in the conventional fluoroscopy group, and all 10 screws were in safe zones in the navigation group. Percutaneous screw fixation using the Iso-C 3D computer-assisted navigation system significantly reduced the intraoperative fluoroscopy time and blood loss in percutaneous screwing for acetabular anterior column fracture. The Iso-C 3D computer-assisted navigation system provided a reliable and effective method for percutaneous screw insertion in acetabular anterior column fractures compared to conventional fluoroscopy. PMID:26765448

  16. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    PubMed Central

    Bollini, Gérard; Legaye, Jean; Tardieu, Christine; Prat-Pradal, Dominique; Chabrol, Brigitte; Jouve, Jean-Luc; Duval-Beaupère, Ginette; Pélissier, Jacques

    2014-01-01

    Acetabular cup orientation (inclination and anteversion) is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter) emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter) could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society) providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter) could determine the safe range of pelvis tilt (positional parameter) for an individual and not a group. PMID:25006461

  17. Wear of a sequentially annealed polyethylene acetabular liner

    PubMed Central

    Gascoyne, Trevor C; Petrak, Martin J; Turgeon, Thomas R; Bohm, Eric R

    2014-01-01

    Background and purpose We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventional and highly crosslinked polyethylene acetabular liners in the same group of RCT patients, with a minimum of 5 years of postoperative follow-up. Patients and methods Linear penetration of the femoral head into an X3 (Stryker) crosslinked polyethylene (XLPE) liner was measured in 18 patients (19 hips) using radiostereometric analysis (RSA). Femoral head penetration was also measured in 6 patients (6 hips) with a conventional polyethylene liner (CPE), which served as a control group. Results The median proximal femoral head penetration in the XLPE group after 5.5 years was 0.025 mm with a steady-state penetration rate of 0.001 mm/year between year 1 and year 5. The CPE liner showed a median proximal head penetration of 0.274 mm after 7.2 years, at a rate of 0.037 mm/year. Interpretation The Trident X3 sequentially annealed XLPE liner shows excellent in vivo wear resistance compared to non-crosslinked CPE liners at medium-term implantation. The rate of linear head penetration in the XLPE liners after > 5 years of follow-up was 0.001 mm/year, which is in close agreement with the results of previous studies. PMID:25140986

  18. Quantification of clearance and creep in acetabular wear measurements

    PubMed Central

    Gregory, Thomas; Vandenbussche, Eric

    2016-01-01

    Background This study aimed to measure femoral head penetration before occurrence of real wear, and to quantify the portions attributable respectively to clearance and plastic deformations in various acetabular designs. Methods We analyzed CT scans from 15 patients at ‘day five’ after total hip arthroplasty (THA). All patients received Exafit® femoral stems and 28 mm heads: 5 patients had cemented Durasul® all-PE cups, 5 patients had un-cemented Allofit® metal-backed cups, and 5 patients had un-cemented Stafit® dual-mobility cups. We also analyzed CT scans of samples of the three head-cup combinations to compare in vivo and in vitro measurements. Results The mean femoral head penetration measured on ‘day five’ was lower for all-PE cups (0.196 mm) than for metal-backed cups (0.551 mm) and dual-mobility cups (0.634 mm). Conclusions The present study indicates that isolated measurements of femoral head penetration include 0.15–0.46 mm of radial clearance and 0.05–0.27 mm of creep, and confirms that the majority of so-called bedding-in observed in the first post-operative months is not entirely due to wear. PMID:27162781

  19. The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation.

    PubMed

    Phillips, A T M; Pankaj; Usmani, A S; Howie, C R

    2004-01-01

    The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup.

  20. Shape variability of the adult human acetabulum and acetabular fossa related to sex and age by geometric morphometrics. Implications for adult age estimation.

    PubMed

    San-Millán, Marta; Rissech, Carme; Turbón, Daniel

    2017-03-01

    This study aims to explore shape variability of the acetabulum during the human adult life span, in relation to sex and age. The human acetabular shape was analysed in 682 os coxae from three different documented skeletal collections from the Iberian Peninsula. Two landmarks and thirty-two sliding semi-landmarks were used for the geometric morphometric procedures and a clock-wise standard was used for orientation. The 180° meridian (6:00) line was positioned over the midpoint of the acetabular notch and 36 reference points in 10° increments along the rim were marked. Data showed that size, sex and age significantly influence acetabular shape variation. Sex differences were significant in individuals younger than 65 years old and were characterised by males exhibiting relatively extended acetabular rim profiles from 10:00 to 1:00, narrower acetabular notches, and reduced acetabular fossae. In addition, three main age-related changes occurred to the acetabular shape in both sexes: outer acetabular profile modification, with extension from 10:00 to 1:00 and reduction from 7:00 to 9:00, acetabular notch narrowing, and acetabular fossa reduction. The age-related changes that were observed are shared by both sexes and seem to be related to bone production associated with age. Specifically, age appears to affect the entire border of the lunate surface: the acetabular rim, both acetabular horns, and the outer edge of the acetabular fossa. Furthermore, shape data confirmed the clover-leaf shape of the acetabular fossa in both males and females. These results improve our understanding of acetabular shape, and assist in refining age-estimation methods and enhancing hip surgery and rehabilitation.

  1. SEGMENTAL CLAVICLE FRACTURE

    PubMed Central

    Grossi, Evander Azevedo

    2015-01-01

    The aim here was to present an unusual case of segmental clavicle fracture associated with ipsilateral rib fracture. Although the clavicle is very superficial, undetected cases of both types of fracture may occur, because these patients usually suffer multiple trauma. The case of a patient with a fracture of the diaphysis and lateral extremity of the clavicle is described: the patient was treated surgically and an excellent result was achieved. Similar cases in the literature are reviewed and their management is discussed. PMID:27047835

  2. An assessment of fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in endodontically treated teeth: an in vitro study.

    PubMed

    Kumar, Lalit; Pal, Bhupinder; Pujari, Prashant

    2015-01-01

    Endodontically treated teeth with excessive loss of tooth structure would require to be restored with post and core to enhance the strength and durability of the tooth and to achieve retention for the restoration. The non-metallic posts have a superior aesthetic quality. Various core build-up materials can be used to build-up cores on the posts placed in endodontically treated teeth. These materials would show variation in their bonding with the non-metallic posts thus affecting the strength and resistance to fracture of the remaining tooth structure. Aims. The aim of the study was to assess the fracture resistance of three composite resin core build-up materials on three prefabricated non-metallic posts, cemented in extracted endodontically treated teeth. Material and Methods. Forty-five freshly extracted maxillary central incisors of approximately of the same size and shape were selected for the study. They were divided randomly into 3 groups of 15 each, depending on the types of non-metallic posts used. Each group was further divided into 3 groups (A, B and C) of 5 samples each depending on three core build-up material used. Student's unpaired 't' test was also used to analyse and compare each group with the other groups individually, and decide whether their comparisons were statistically significant. Results. Luxacore showed the highest fracture resistance among the three core build-up materials with all the three posts systems. Ti-core had intermediate values of fracture resistance and Lumiglass had the least values of fracture resistance.

  3. Use of porous tantalum for acetabular reconstruction in revision hip arthroplasty.

    PubMed

    Issack, Paul S

    2013-11-06

    ➤ Over the past decade, porous tantalum has emerged as a powerful tool for reconstruction of the failed acetabular component.➤ The increased porosity, high coefficient of friction, and favorable elastic modulus of porous tantalum compared with traditional titanium mesh or cobalt chromium acetabular components allow for greater bone ingrowth potential, implant stability, and host bone preservation, respectively, in porous tantalum shells.➤ Several studies have confirmed the excellent early and midterm results of porous tantalum reconstruction for revision hip arthroplasty.➤ Depending on the degree of bone loss, excellent results have been achieved with modular or revision porous tantalum shells, tantalum shells with tantalum augments, and cup-cage constructs.➤ These implants and techniques are greatly changing the approach to acetabular revision surgery and are providing constructs with greater stability and more physiologic biomechanical properties than those achieved through the use of traditional reconstructive methods.

  4. Oxidation and other property changes of retrieved sequentially annealed UHMWPE acetabular and tibial bearings.

    PubMed

    Reinitz, Steven D; Currier, Barbara H; Van Citters, Douglas W; Levine, Rayna A; Collier, John P

    2015-04-01

    This investigation analyzed retrieved sequentially crosslinked and annealed (SXL) ultra-high molecular weight polyethylene bearings to determine whether the material is chemically stable in vivo. A series of retrieved tibial and acetabular components were analyzed for changes in ketone oxidation, crosslink density, and free radical concentration. Oxidation was observed to increase with in vivo duration, and the rate of oxidation in tibial inserts was significantly greater than in acetabular liners. SXL acetabular bearings oxidized at a rate comparable to gamma-sterilized liners, while SXL tibial inserts oxidized at a significantly faster rate than their gamma-sterilized counterparts. A significant decrease in crosslink density with increased mean ketone oxidation index was observed, suggesting that in vivo oxidation may be causing material degradation. Furthermore, a subsurface whitened damage region was also found in a subset of the bearings, indicating the possibility of a clinically relevant decrease in mechanical properties of these components.

  5. Cementation of a polyethylene liner into a metal acetabular shell: a biomechanical study.

    PubMed

    Hofmann, Aaron A; Prince, Edward J; Drake, F Thurston; Hunt, Kenneth J

    2009-08-01

    Cementation of a liner into a well-fixed acetabular shell is common in revision hip arthroplasty. We compare the biomechanical strengths of cemented liners with standard locked liners. Fifty polyethylene liners were inserted into acetabular shells using the standard locking mechanism or 1 of 2 cement types then loaded to failure by torsion or lever-out testing. Lever-out testing showed that all cemented liners failed at similar loads to standard locked liners. With torsion testing, cemented liners failed at significantly higher loads than standard locked liners; roughening the liner increased load to failure. Cementation of an acetabular liner into a metal shell is safe and strong and a good alternative to metal shell replacement. Saw roughening of the polyethylene liner strengthens the poly-cement interface.

  6. End-stage posttraumatic osteoarthritis treated with THA in osteogenesis imperfecta.

    PubMed

    Chaus, George W; Heare, Travis

    2012-06-01

    Osteogenesis imperfecta is an incurable genetic disorder manifested with altered bone quality that predisposes patients to a multitude of fractures throughout their lives, including acetabular fractures. The management of acetabular fractures in patients with osteogenesis imperfecta remains a challenging clinical problem, with a paucity of literature supporting treatments and their outcomes. Limited reports in the literature validate the use of total hip arthroplasty (THA) in patients with osteogenesis imperfecta, and they describe the adult population only.This article describes a case of delayed diagnosis of a transverse acetabular fracture and femoral head impaction fracture that led to posttraumatic end-stage hip osteoarthritis in a 16-year-old boy with osteogenesis imperfecta (Sillence Type I) that was sustained after minimal trauma. Clinical examination 3 months postinjury revealed a significant pelvic obliquity, severe pain with hip range of motion, and limited hip range of motion. Imaging studies revealed a complete loss of articular cartilage and significant joint effusion.The patient underwent THA. No postoperative complications occurred. Two-year follow-up showed an excellent clinical result. The patient's hip was pain free, and he was able to walk with no limp.The authors are unaware of any reported cases of children with osteogenesis imperfecta undergoing THA. Based on the reported literature and the authors' experience, THA can be a reliable surgical option for patients with osteogenesis imperfecta.

  7. The efficacy of the use of IR laser phototherapy associated to biphasic ceramic graft and guided bone regeneration on surgical fractures treated with miniplates: a histological and histomorphometric study on rabbits.

    PubMed

    Pinheiro, Antonio L B; Aciole, Gilberth Tadeu Santos; Ramos, Thais Andrade; Gonzalez, Tayná Assunção; da Silva, Laís Nogueira; Soares, Luiz G Pinheiro; Aciole, Jouber Mateus Santos; dos Santos, Jean Nunes

    2014-01-01

    The aim of the present study was to assess, by light microscopy and histomorphometry, the repair of surgical fractures fixed with internal rigid fixation (IRF) treated or not with IR laser (λ780 nm, 50 mW, 4 × 4 J/cm(2) = 16 J/cm(2), ϕ = 0.5 cm(2), CW) associated or not to the use of hydroxyapatite and guided bone regeneration. Surgical tibial fractures were created under general anesthesia on 15 rabbits that were divided into 5 groups, maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet, and had water ad libidum. The fractures in groups II, III, IV, and V were fixed with miniplates. Animals in groups III and V were grafted with hydroxyapatite and GBR technique used. Animals in groups IV and V were irradiated at every other day during two weeks (4 × 4 J/cm(2), 16 J/cm(2) = 112 J/cm(2)). Observation time was that of 30 days. After animal death, specimens were taken, routinely processed to wax, cut and stained with HA and Sirius red, and used for histological assessment. The results of both analyses showed a better bone repair on all irradiated subjects especially when the biomaterial and GBR were used. In conclusion, the results of the present investigation are important clinically as they are suggestive that the association of hydroxyapatite, and laser light resulted in a positive and significant repair of complete tibial fractures treated with miniplates.

  8. Transstyloid, transscaphoid, transcapitate fracture: a variant of scaphocapitate fractures

    PubMed Central

    Burke, Neil G; Cosgrave, Ciaran H; O'Neill, Barry James; Kelly, Eamonn P

    2014-01-01

    Transstyloid, transscaphoid, transcapitate fractures are uncommon. We report the case of a 28-year-old man who sustained this fracture following direct trauma. The patient was successfully treated by open reduction internal fixation of the scaphoid and proximal capitate fragment, with a good clinical outcome at 1-year follow-up. This pattern is a new variant of scaphocapitate fracture as involves a fracture of the radial styloid as well. PMID:24686808

  9. Triplane fractures in the hand.

    PubMed

    Garcia Mata, S; Hidalgo Ovejero, A; Martinez Grande, M

    1999-02-01

    Two new cases of triplane fracture of the distal tibia are reported in the proximal phalanx of the thumb and the distal radius, respectively, of a 12-year-old girl and a 13-year-old boy. Neither fracture showed any displacement, achieving healing at 4 weeks of external immobilization. Triplane fractures can occur across growth plates other than the distal tibia. Because of the rapid physiologic physeal arrest, the potential for growth deformity is null. In cases without displacement, these fractures should be treated conservatively by external immobilization, as one would treat a one-plane fracture.

  10. Tibial fractures in children

    PubMed Central

    Palmu, Sauli A; Auro, Sampo; Lohman, Martina; Paukku, Reijo T; Peltonen, Jari I; Nietosvaara, Yrjänä

    2014-01-01

    Background Tibial fracture is the third most common long-bone fracture in children. Traditionally, most tibial fractures in children have been treated non-operatively, but there are no long-term results. Methods 94 children (64 boys) were treated for a tibial fracture in Aurora City Hospital during the period 1980–89 but 20 could not be included in the study. 58 of the remaining 74 patients returned a written questionnaire and 45 attended a follow-up examination at mean 27 (23–32) years after the fracture. Results 89 children had been treated by manipulation under anesthesia and cast-immobilization, 4 by skeletal traction, and 1 with pin fixation. 41 fractures had been re-manipulated. The mean length of hospital stay was 5 (1–26) days. Primary complications were recorded in 5 children. The childrens’ memories of treatment were positive in two-thirds of cases. The mean subjective VAS score (range 0–10) for function appearance was 9. Leg-length discrepancy (5–10 mm) was found clinically in 10 of 45 subjects and rotational deformities exceeding 20° in 4. None of the subjects walked with a limp. None had axial malalignment exceeding 10°. Osteoarthritis of the hip and/or knee was seen in radiographs from 2 subjects. Interpretation The long-term outcome of tibial fractures in children treated non-operatively is generally good. PMID:24786903

  11. Management of fractures in adolescents.

    PubMed

    Parikh, Shital N; Wells, Lawrence; Mehlman, Charles T; Scherl, Susan A

    2011-01-01

    There are well-established treatment standards for adults who sustain fractures; however, these treatment standards are not always applicable when treating adolescents with similar fractures because of the presence of physes. Fractures in adolescents are treated by pediatric orthopaedic surgeons, adult orthopaedic traumatologists, or general orthopaedic surgeons. It is imperative that the principles of fracture management are well defined and discussed in both the pediatric and adult orthopaedic community. Controversial topics include the youngest age at which an adolescent can be treated as an adult and acceptable fracture reduction criteria. The general principles of managing fractures in adolescents regarding classification, treatment options, complications, and estimating skeletal age should be understood by the treating physician.

  12. Open tibial fractures grade IIIC treated successfully with external fixation, negative-pressure wound therapy and recombinant human bone morphogenetic protein 7.

    PubMed

    Babiak, Ireneusz

    2014-10-01

    The aim of the therapy in open tibial fractures grade III was to cover the bone with soft tissue and achieve healed fracture without persistent infection. Open tibial fractures grade IIIC with massive soft tissue damage require combined orthopaedic, vascular and plastic-reconstructive procedures. Negative-pressure wound therapy (NPWT), used in two consecutive cases with open fracture grade IIIC of the tibia diaphysis, healed extensive soft tissue defect with exposure of the bone. NPWT eventually allowed for wound closure by split skin graft within 21-25 days. Ilizarov external fixator combined with application of recombinant human bone morphogenetic protein-7 at the site of delayed union enhanced definitive bone healing within 16-18 months.

  13. Effect of three different core materials on the fracture resistance of endodontically treated deciduous mandibular second molars: an in vitro study.

    PubMed

    Shah, Preetam; Gugwad, Sachin C; Bhat, Chetan; Lodaya, Rahul

    2012-01-01

    Endodontic treatment makes the tooth brittle due to loss of bulk of tooth structure, decrease in the moisture content of dentin and dentin elasticity. The following study was carried out to evaluate the effect of endodontic treatment on the fracture resistance of the tooth and reinforcing ability of three different core materials. The following study comprised of sample size of 30 deciduous second molars divided into control group (6) and test group (24). Access opening was done in 24 and 18th teeth with access opening were restored with three different core materials namely IRM (6), silver amalgam (6), GIC (6). All the 30 were subjected to fracture test using UTM (Universal testing machine)- Instron 95. Result showed a drastic reduction in the fracture resistance of the tooth on access opening (1/3rd) and out of the three core materials glass ionomer was shown to be the best core material giving the highest fracture registrance followed by silver amalgam and IRM.

  14. Importance of greenstick lamina fractures in low lumbar burst fractures

    PubMed Central

    Ersozlu, S.; Aydinli, U.

    2006-01-01

    Lumbar burst fractures (L3–L5) represent a small percentage of all spinal fractures. The treatment of fractures involving the lumbar spine has been controversial. Lamina fractures may be complete or of the greenstick type. Dural tears and nerve root entrapment may accompany these lamina fractures. The aim of this retrospective study was to determine the incidence of dural tear in patients who had lumbar burst fractures with greenstick lamina fractures and the importance of these lamina fractures when choosing the optimum treatment. Twenty-six patients with 28 lumbar burst fractures were treated from 1995 through 2002. The average follow-up was 60 months (range 32–110 months). The male to female ratio was 21:5 and the mean age was 37 years (17–64). Dural tear was detected in seven (25%) out of 28 burst fractures. The functional outcome of the entire study group was assessed using the Smiley-Webster Scale. Good to excellent results were obtained in 24 (92%) of 26 patients. Lumbar burst fractures with greenstick lamina fractures occur mostly in the L2–L4 area. In the surgical treatment, any reduction manoeuvre will close the fracture and crush the entrapped neural elements. Therefore, it may be better to explore the greenstick lamina fracture whether there is any neural entrapment or not, before any reduction manoeuvre is attempted. PMID:16501977

  15. Shoulder Fractures

    MedlinePlus

    ... Journal of Hand Surgery (JHS) Home Anatomy Shoulder Fractures Email to a friend * required fields From * To * ... create difficulty with its function. Types of Shoulder Fractures The type of fracture varies by age. Most ...

  16. Stress Fractures

    MedlinePlus

    Stress fractures Overview By Mayo Clinic Staff Stress fractures are tiny cracks in a bone. They're caused by ... up and down or running long distances. Stress fractures can also arise from normal use of a ...

  17. Greenstick Fractures

    MedlinePlus

    Greenstick fractures Overview By Mayo Clinic Staff A greenstick fracture occurs when a bone bends and cracks, instead of breaking completely into separate pieces. The fracture looks similar to what happens when you try ...

  18. Role of preoperative 3-dimensional computed tomography reconstruction in depressed skull fractures treated with craniectomy: a case report of forensic interest.

    PubMed

    Viel, Guido; Cecchetto, Giovanni; Manara, Renzo; Cecchetto, Attilio; Montisci, Massimo

    2011-06-01

    Patients affected by cranial trauma with depressed skull fractures and increased intracranial pressure generally undergo neurosurgical intervention. Because craniotomy and craniectomy remove skull fragments and generate new fracture lines, they complicate forensic examination and sometimes prevent a clear identification of skull fracture etiology. A 3-dimensional reconstruction based on preoperative computed tomography (CT) scans, giving a picture of the injuries before surgical intervention, can help the forensic examiner in identifying skull fracture origin and the means of production.We report the case of a 41-year-old-man presenting at the emergency department with a depressed skull fracture at the vertex and bilateral subdural hemorrhage. The patient underwent 2 neurosurgical interventions (craniotomy and craniectomy) but died after 40 days of hospitalization in an intensive care unit. At autopsy, the absence of various bone fragments did not allow us to establish if the skull had been stricken by a blunt object or had hit the ground with high kinetic energy. To analyze bone injuries before craniectomy, a 3-dimensional CT reconstruction based on preoperative scans was performed. A comparative analysis between autoptic and radiological data allowed us to differentiate surgical from traumatic injuries. Moreover, based on the shape and size of the depressed skull fracture (measured from the CT reformations), we inferred that the man had been stricken by a cylindric blunt object with a diameter of about 3 cm.

  19. Assessment of bone healing on tibial fractures treated with wire osteosynthesis associated or not with infrared laser light and biphasic ceramic bone graft (HATCP) and guided bone regeneration (GBR): Raman spectroscopy study

    NASA Astrophysics Data System (ADS)

    Bastos de Carvalho, Fabíola; Aciole, Gilberth Tadeu S.; Aciole, Jouber Mateus S.; Silveira, Landulfo, Jr.; Nunes dos Santos, Jean; Pinheiro, Antônio L. B.

    2011-03-01

    The aim of this study was to evaluate, through Raman spectroscopy, the repair of complete tibial fracture in rabbits fixed with wire osteosynthesis - WO, treated or not with infrared laser light (λ 780nm, 50mW, CW) associated or not to the use of HATCP and GBR. Surgical fractures were created under general anesthesia (Ketamine 0.4ml/Kg IP and Xilazine 0.2ml/Kg IP), on the tibia of 15 rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with WO. Animals of groups III and V were grafted with hydroxyapatite + GBR technique. Animals of groups IV and V were irradiated at every other day during two weeks (16J/cm2, 4 x 4J/cm2). Observation time was that of 30 days. After animal death the specimens were kept in liquid nitrogen for further analysis by Raman spectroscopy. Raman spectroscopy showed significant differences between groups (p<0.001). It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of calcium hydroxyapatite.

  20. Effectiveness of an Acetabular Positioning Device in Primary Total Hip Arthroplasty

    PubMed Central

    Hendrix, Stephen L.; Mologne, Timothy S.; Peterson, Drew A.; Holley, Keith A.

    2005-01-01

    To evaluate the efficacy of a commercially available acetabular positioning device, we performed a prospective evaluation of 40 consecutive patients undergoing primary total hip arthroplasty. All surgery was performed by the same surgeon, in the same operating room, and on the same operating table. The acetabular positioning device was designed to place the component in 45° of abduction. At 6 weeks, all radiographs were evaluated by 3 investigators not involved with the surgery. Each radiograph was evaluated by each reviewer on 3 separate occasions, blinded to the findings of the other reviewer to assess interobserver and intraobserver variability. The mean cup abduction angle was 42.1°, with a range from 23° to 57° (SD 8.3°). Intraobserver and interobserver variability were 0.2 and 0.3°, respectively. The findings of this study demonstrate a wide variability in acetabular cup placement in primary total hip arthroplasty. We believe this is due to movement of the pelvis, which may occur during preparation, draping, and retracting during surgery. We feel surgeons should not rely solely on positioning devices when implanting the acetabular component in total hip arthroplasty. Identification of bone landmarks and determination of superolateral implant coverage noted on preoperative templating is advocated to improve the precision of component position. PMID:18751812

  1. Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements.

    PubMed

    Alshuhri, Abdullah A; Holsgrove, Timothy P; Miles, Anthony W; Cunningham, James L

    2015-08-01

    Current techniques for diagnosing early loosening of a total hip replacement (THR) are ineffective, especially for the acetabular component. Accordingly, new, accurate, and quantifiable methods are required. The aim of this study was to investigate the viability of vibrational analysis for accurately detecting acetabular component loosening. A simplified acetabular model was constructed using a Sawbones(®) foam block. By placing a thin silicone layer between the acetabular component and the Sawbones block, 2- and 4-mm soft tissue membranes were simulated representing different loosening scenarios. A constant amplitude sinusoidal excitation with a sweep range of 100-1500 Hz was used. Output vibration from the model was measured using an accelerometer and an ultrasound probe. Loosening was determined from output signal features such as the number and relative strength of observed harmonic frequencies. Both measurement methods were sufficient to measure the output vibration. Vibrational analysis reliably detected loosening corresponding to both 2 and 4 mm tissue membranes at driving frequencies between 100 and 1000 Hz (p < 0.01) using the accelerometer. In contrast, ultrasound detected 2-mm loosening at a frequency range of 850-1050 Hz (p < 0.01) and 4-mm loosening at 500-950 Hz (p < 0.01).

  2. Clinical and radiological outcome of the cemented Contemporary acetabular component in patients < 50 years of age.

    PubMed

    Schmitz, M W J L; Timmer, C; Rijnen, W H C; Gardeniers, J W M; Schreurs, B W

    2013-12-01

    Despite the worldwide usage of the cemented Contemporary acetabular component (Stryker), no published data are available regarding its use in patients aged < 50 years. We undertook a mid- to long-term follow-up study, including all consecutive patients aged < 50 years who underwent a primary total hip replacement using the Contemporary acetabular component with the Exeter cemented stem between January 1999 and January 2006. There were 152 hips in 126 patients, 61 men and 65 women, mean age at surgery 37.6 years (16 to 49 yrs). One patient was lost to follow-up. Mean clinical follow-up of all implants was 7.6 years (0.9 to 12.0). All clinical questionnaire scores, including Harris hip score, Oxford hip score and several visual analogue scales, were found to have improved. The eight year survivorship of all acetabular components for the endpoints revision for any reason or revision for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2 to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up was complete for 146 implants. The eight year survival for the endpoint radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving implants were considered radiologically loose but were asymptomatic. The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent lines (n = 20, 13.9%) in the 144 surviving cups indicates a need for continued observation in the second decade of follow-up in order to observe their influence on long-term survival. The clinical and radiological data resulting in a ten-year survival rate > 90% in young patients support the use of the Contemporary acetabular component in this specific patient group.

  3. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    PubMed

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  4. Effects of recombinant human Bone Morphogenetic Protein-2 (rhBMP-2) in grade III open tibia fractures treated with unreamed nails-A clinical and health-economic analysis.

    PubMed

    Alt, Volker; Borgman, Benny; Eicher, Alexander; Heiss, Christian; Kanakaris, Nikolaos K; Giannoudis, Peter V; Song, Fujian

    2015-11-01

    Recombinant human Bone Morphogenetic Protein-2 (rhBMP-2) is licensed in Europe for open tibia fractures treated with unreamed nails. However, there is limited data available on the specific use of rhBMP-2 in combination with unreamed nails for open tibia fractures. The intention of the current study was to evaluate the medical and health-economic effects of rhBMP-2 in Gustilo-Anderson grade III open tibia fractures treated with unreamed nails based on individual patient data from two previously published studies. Linear regression analysis was performed on raw data of 90 patients that were either treated by standard of care with soft tissue management and unreamed nailing (SOC group) (n=50) or with rhBMP-2 in addition to soft tissue management and unreamed nailing (rhBMP-2 group) (n=40). For all types of revision, a significant lower percentage of patients (27.5%) of the rhBMP-2 group had to be revised compared to 48% of the patients of the SOC group (p=0.04). When only invasive secondary interventions such as bone grafting and nail exchange were considered, there was also a statistically significant reduction in the rhBMP-2 group with a revision rate of 10.0% (4 of 40 patients) compared to the SOC group with a revision rate of 28.0% (14 of 50 patients) (p=0.01). Mean fracture healing time of 228 days in the rhBMP-2 compared to 266 days in the SOC group was not statistically significant (p=0.24). Health-economic analysis based on a societal perspective with calculation of overall treatment costs after initial surgery and including productivity losses revealed savings of €6,239 per patient for Germany and €4,752 for the UK in favour of rhBMP-2 which was mainly driven by reduction of productivity losses. In conclusion, rhBMP-2 reduces secondary interventions in patients with grade III open tibia fractures treated with an unreamed nail and its use leads to financial savings for Germany and the UK from a societal perspective.

  5. [Fracture arthroplasty of femoral neck fractures].

    PubMed

    Braun, K F; Hanschen, M; Biberthaler, P

    2016-04-01

    A paradigm shift in the treatment of elderly patients has recently taken place leading to an increase in joint replacement surgery. The aim of this article is to highlight new developments and to present a treatment algorithm for femoral neck fractures. The age limit must be individually determined considering the comorbidities and perioperative risk profile. Pertrochanteric femoral fractures are nearly exclusively treated by osteosynthesis regardless of age. The situation for femoral neck fractures is more complex. Patients younger than 65 years should generally be treated by osteosynthesis but patients older than 65 years benefit from hemiarthroplasty or total hip arthroplasty. In patients aged between 65 and 75 years with high functional demands and a justifiable perioperative risk, total joint replacement is the treatment of choice. In physically less active patients older than 75 years and poor general condition, preference should be given to hemiarthroplasty.

  6. Central dislocation of the hip secondary to insufficiency fracture.

    PubMed

    Thaya, H Moe; Sivaloganathan, Sivan; Sankey, A; Gibbons, Charles E

    2010-03-20

    We present a case report of a 45-year old man who sustained a central dislocation of the hip secondary to an insufficiency fracture of the acetabulum. At the time of presentation he was on alendronate therapy for osteoporosis which had been previously investigated. CT scanning of the pelvis was useful for pre-operative planning which confirmed collapse of the femoral head but no discontinuity of the pelvis. The femoral head was morcellized and used as bone graft for the acetabular defect and an uncemented total hip replacement was performed.

  7. Central dislocation of the hip secondary to insufficiency fracture

    PubMed Central

    Thaya, H.Moe; Sivaloganathan, Sivan; Sankey, A; Gibbons, Charles E.

    2010-01-01

    We present a case report of a 45-year old man who sustained a central dislocation of the hip secondary to an insufficiency fracture of the acetabulum. At the time of presentation he was on alendronate therapy for osteoporosis which had been previously investigated. CT scanning of the pelvis was useful for pre-operative planning which confirmed collapse of the femoral head but no discontinuity of the pelvis. The femoral head was morcellized and used as bone graft for the acetabular defect and an uncemented total hip replacement was performed. PMID:21808700

  8. Phalangeal fractures: displaced/nondisplaced.

    PubMed

    Gaston, R Glenn; Chadderdon, Christopher

    2012-08-01

    Nonsurgical management is the preferred treatment of stable, extra-articular fractures of the proximal and middle phalanx, most distal phalanx fractures, and, rarely, nondisplaced intraarticular fractures in elite athletes. Techniques that afford maximal strength with minimal dissection, thus allowing earlier return to play, are ideal. Open reduction with internal fixation with plate fixation is most often chosen for unstable phalangeal shaft fractures in high-demand athletes to provide rigid internal fixation and allow immediate range of motion and more rapid return to sport. It is our practice to routinely treat unicondylar fractures with surgery with percutaneous headless compression screws in elite athletes.

  9. Impending Atypical Femoral Fracture in Patients With Medullary Thyroid Cancer With Skeletal Metastasis Treated With Long-term Bisphosphonate and Denosumab.

    PubMed

    Koizumi, Mitsuru; Gokita, Tabu; Toda, Kazuhisa

    2017-02-24

    Atypical femoral fractures (AFFs) occur in osteoporosis patients receiving long-term bisphosphonate. Atypical femoral fractures also occur in cancer patients receiving long-term bisphosphonate or denosumab, but the prevalence is low. We describe a 53-year-old woman with a history of medullary thyroid cancer and skull metastasis who was prescribed bisphosphonate for 6 years and denosumab for 1.5 years, consecutively. Bone scintigraphy performed because of spontaneous groin pain showed uptake in the lateral aspect of the left femur, which was confirmed as impending AFF. In oncological patients receiving long-term bisphosphonate or denosumab, AFF should be included as a differential diagnosis with focal femoral findings.

  10. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    PubMed

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction.

  11. Total arthroplasty in displaced dysplastic hips with acetabular reconstruction and femoral shortening – technical note☆☆☆

    PubMed Central

    Silva, Paulo; de Oliveira, Leandro Alves; Coelho, Danilo Lopes; do Amaral, Rogério Andrade; Rebello, Percival Rosa; de Moraes, Frederico Barra

    2014-01-01

    To describe a new procedure of total hip replacement in patient with severe developmental dysplasia of the left hip, using technique of acetabular reconstruction with autogenous bone grafts and subtrochanteric shortening femoral osteotomy. Total hip replacement done in January of 2003. The Eftekhar's classification was used and included type D, neglected dislocations. Bone graft incorporated in acetabular shelf and femoral osteotomy. Our contribution is the use of an Allis plate to better fix acetabular grafts, avoiding loosening, and cerclage around bone graft in femoral osteotomy site, which diminish pseudoarthrosis risk. This technique shows efficiency, allowing immediately resolution for this case with pain and range of motion of hip improvement. It also allows the acetabular dysplasia reconstruction, equalization of the limb length (without elevated risk of neurovascular lesion) and repairs the normal hip biomechanics due to the correction of the hip's center of rotation. PMID:26229775

  12. Should orthopedic surgeons consider the effects of gabapentin administration on bone healing while treating a long bone fracture: experimental study in a rat model

    PubMed Central

    Sofu, Hakan; Kockara, Nizamettin; Aydin, Bahattin Kerem; Suleyman, Bahadir; Tayfur, Mahir; Malkoc, Ismail

    2016-01-01

    Objective: The main purpose of the present study was to assess the radiographic, histological, and mechanical effects of gabapentin on fracture healing in a rat model of femur fracture. Materials and methods: A standard transverse fracture of the mid-diaphysis was created. A total of 60 female Wistar-Albino rats with the mean age of 13.5 ± 1.2 weeks were used for this experimental trial. The rats were randomized into four groups with 15 animals included in each group. Group A and B were the control groups whereas C and D were the treatment groups. Drugs were delivered by oral gavage twice a day with the daily dosage calculated according to body surface area conversion to the human equivalent dosing regimen of 1200 mg/day. Radiographic, histological, and biomechanical evaluation was performed. Results: We could not detect any statistically significant difference between the control and gabapentin treatment groups according to the comparative assessment of radiographic scores on the 15th and 30th days. Although no significant differences were found between the groups on the 15th day, histological scores were better in the control group on the 30th day. According to the results of biomechanical testing, the fractured femurs resected from the control group exhibited significantly more strength on the 30th day. Conclusions: According to the data we acquired during the present study, administration of gabapentin negatively affects the fracture healing process especially in the aspects of histological progression as well as the biomechanical strength of the callus in a rat model. PMID:27801642

  13. Radiographic anatomy of the proximal femur: correlation with the occurrence of fractures

    PubMed Central

    Pires, Robinson Esteves Santos; Prata, Eric Fontes; Gibram, Athos Vilela; Santos, Leandro Emilio Nascimento; Lourenço, Paulo Roberto Barbosa de Toledo; Belloti, João Carlos

    2012-01-01

    Objective To evaluate the correlation between radiographic parameters of the proximal femur anatomy and fractures. Methods Three hundred and five digital x-rays of the pelvis were analyzed in the anteroposterior view. Of these x-rays, twenty-seven showed femoral neck or transtrochanteric fractures. The anatomical parameters analyzed were: femoral neck width (FNW), femoral neck length (FNL), femoral axis length (FAL), cervicodiaphyseal angle (CDA), acetabular tear-drop distance (ATD) and great trochanter-pubic symphysis distance (GTPSD). The analysis was performed by comparing the results of the x-rays with and without proximal femoral fracture, to establish a correlation between them. Results No differences were found between the anatomical parameters of the groups with and without proximal femoral fracture. Conclusion There was no association between anatomical changes in the proximal femur and greater susceptibility to fractures. Level of evidence IV, Cross-sectional Study. PMID:24453585

  14. Fracturing from highly deviated and horizontal wells: Numerical analysis of non-planar fracture propagation

    SciTech Connect

    Olson, J.E.

    1995-12-31

    Fracturing from horizontal and highly deviated wells can often result in complex, non-planar fracture geometry. A two-dimensional model was developed to analyze the effects of non-planar fracture propagation for different in situ boundary conditions and hydraulic fracturing parameters. Numerical simulations show that curving fracture geometry reduces created fracture length compared to a planar fracture and causes a fracture width restriction at the wellbore. Reduction in fracture length can reduce expected well stimulation effects and jeopardize well economics. Near-wellbore width restrictions increase fracture treating pressure and may cause wellbore screen-out during the proppant stages of a fracturing treatment. The negative impact of non-planar geometry can be mitigated with short perforated intervals, high viscosity fracturing fluids, proper wellbore alignment and pre-pad proppant slugs for near-wellbore erosion.

  15. High Complication Rate With Anterior Total Hip Arthroplasties on a Fracture Table

    PubMed Central

    Collis, Dennis K.

    2010-01-01

    Background Recent attention in THA has focused on minimally invasive techniques and their short-term outcomes. Despite much debate over the outcomes and complications of the two-incision and the mini-lateral and mini-posterior approaches, complications arising from use of the anterior THA on a fracture table are not well documented. Questions/purposes We determined the intraoperative and postoperative complications with the anterior approach to THA through an extended single-surgeon patient series. Methods We reviewed 800 primary THAs performed anteriorly with the aid of a fracture table over 5 years and recorded all intraoperative and postoperative complications up to latest followup (average, 1.8 years; range, 0–5 years). Patients with severe acetabular deformity or severe flexion contractures were excluded and those surgeries were performed with a lateral approach during the time period of this study. Results Intraoperative complications included 19 trochanteric fractures, three femoral perforations, one femoral fracture, one acetabular fracture, one bleeding complication, and one case of cardiovascular collapse. There were no ankle fractures. Postoperative complications included seven patients with dislocations; seven with deep infections; one with delayed femur fracture; 37 with wound complications, among which 13 had reoperation for local débridement; 14 with deep venous thrombosis; and two with pulmonary embolism; and 31 other nonfatal medical complications. Conclusions The main intraoperative complications of trochanteric fractures and perforations occurred mostly early in the series, while the main postoperative complications related to wound healing were prevalent throughout the entire series. Despite potential advantages of use of a fracture table, surgeons should be aware of the potential complications of trochanteric fractures, perforations, and wound-healing problems associated with this technique. Level of Evidence Level IV, therapeutic study

  16. Analysis of zygomatic fractures.

    PubMed

    Hwang, Kun; Kim, Dong Hyun

    2011-07-01

    The purpose of this study was to evaluate the natural history of zygomatic fractures in 469 cases over 14 years. The medical records of patients seeking treatment for zygomatic fractures were reviewed. The zygomatic fractures were classified as monopod, dipod, or tripod fractures for most patients. The monopod fractures included (1) zygomaticofrontal, (2) zygomaticomaxillary, and (3) zygomatic arch fractures. The dipod fractures were subclassified into 3 types according to combination of the previously mentioned 3 sites, which were 1 and 2, 1 and 3, and 2 and 3. Tripod fracture included all 1, 2, and 3. Among 469 cases of zygomatic fractures, tripod fractures (n = 238, 50.7%), zygomaticomaxillary fracture (n = 121, 25.8%), and isolated fracture of the zygomatic arch (n = 98 20.9%) formed most of the cases (n = 457, 97.4%). About one-half cases were tripod fractures (n = 238, 50.7%), and another half cases were monopod fractures (n = 220, 46.9%). Only 11 cases (2.4%) were dipod fractures. Most of the monopod fractures were zygomaticomaxillary (n = 121, 25.8%) and zygomatic arch fractures (n = 98, 20.9%). Among the dipod fractures, no cases of zygomaticofrontal and zygomatic arch fractures were reported. An open reduction was performed in 73.8% (346 cases), closed reduction in 24.5% (115 cases), and conservative treatment in only 1.7%. In tripod fracture (n = 238), an open reduction and internal fixation was performed for most of the cases (n = 225, 94.5%), and closed reduction was performed in only 11 cases (4.6%). In monopod zygomaticomaxillary fracture (n = 121), internal fixation was performed for most of the cases (n = 108, 89.3%), and closed reduction was performed in only 9 cases (7.7%). However, in monopod fracture of the zygomatic arch (n = 98), most of the cases (n = 95, 96.9%) were treated with closed reduction; open reduction was performed in only 1 case (1.0%). At zygomaticofrontal area (n = 241), internal fixation was performed in most of the cases (n

  17. Lateral foot pain following open reduction and internal fixation of the fracture of the fifth metatarsal tubercle: treated by arthroscopic arthrolysis and endoscopic tenolysis.

    PubMed

    Lui, Tun Hing

    2014-04-17

    We report a case of fracture of the tuberosity of the fifth metatarsal which was managed by tension band wiring and bone grafting. It was complicated by symptomatic fibrosis of the operated site involving the cubometatarsal joint, peroneus brevis tendon, peroneus tertius tendon and the long extensor tendon to the fifth toe. This was successfully managed by arthroscopic lysis of the involved joint and tendons.

  18. An in vitro comparative evaluation of different intraorifice barriers on the fracture resistance of endodontically treated roots obturated with gutta-percha

    PubMed Central

    Gupta, Abhishek; Arora, Vipin; Jha, Padmanabh; Nikhil, Vineeta; Bansal, Parul

    2016-01-01

    Aim: To compare and evaluate the root reinforcement potential of four different intraorifice barriers: Mineral trioxide aggregate (MTA), resin-modified glass ionomer cement (RMGIC), fiber-reinforced composite (FRC), and nanohybrid composite (NC). Materials and Methods: Seventy-five mandibular premolars were decoronated to a standardized length, and prepared and obturated with gutta-percha and AH Plus sealer. Except for control specimens, the coronal 3-mm gutta-percha was removed and filled with different materials. The specimens (75) were divided into five groups (n = 15) on the basis of the intraorifice barrier material used. Group 1: MTA, Group 2: RMGIC, Group 3: FRC, Group 4: NC, Group 5: no barrier (control). Fracture resistance of the specimens was tested. Results: Fracture resistance of roots was significantly affected by the type of intraorifice barrier used and the following pattern was observed: RMGIC > FRC > NC > MTA. Conclusion: Intraorifice barriers can be regarded as a viable choice to reduce the occurrence of postendodontic root fractures. Among the four tested materials, RMGIC showed the maximum reinforcement. PMID:27099413

  19. Time to death in a prospective cohort of 252 patients treated for fracture of the proximal femur in a major hospital in Portugal.

    PubMed

    Campos, Sónia; Alves, Sandra Maria Ferreira; Carvalho, Marilia Sá; Neves, Nuno; Trigo-Cabral, Abel; Pina, Maria Fátima

    2015-07-01

    The objectives were to analyze one-year survival and mortality predictors in patients with fracture of the proximal femur (low/moderate trauma). A prospective cohort was formed by inviting all patients hospitalized in the Orthopedic Ward of the second largest hospital in Portugal (May 2008-April 2009). Survival was assessed at 3, 6, 9, and 12 months after fracture and related to demographic factors, lifestyle, and clinical history, as well as to data from medical records (fracture type, surgery date, surgical treatment, and preoperative risk). Of the 340 patients hospitalized, 252 were included (78.9% women). Mortality at 3, 6, 9, and 12 months was 21.2%, 25%, 28.8%, and 34.6% for men and 7.8%, 13.5%, 19.2%, and 21.4% for women, respectively. Predictors of death were male gender (HR = 2.54; 95%CI: 1.40-4.58), ASA score III/IV vs. I/II (HR = 1.95; 95%CI: 1.10-3.47), age (HR = 1.06; 95%CI: 1.03-1.10), and delay in days to surgery (HR = 1.07; 95%CI: 1.03-1.12). Factors related to death were mainly related to patients' characteristics at admission.

  20. The efficacy of the use of IR laser phototherapy associated to biphasic ceramic graft and guided bone regeneration on surgical fractures treated with miniplates: a Raman spectral study on rabbits.

    PubMed

    Pinheiro, Antonio L B; Santos, Nicole Ribeiro Silva; Oliveira, Priscila Chagas; Aciole, Gilberth Tadeu Santos; Ramos, Thais Andrade; Gonzalez, Tayná Assunção; da Silva, Laís Nogueira; Barbosa, Artur Felipe Santos; Silveira, Landulfo

    2013-02-01

    The aim of the present study was to assess, by Raman spectroscopy, the repair of surgical fractures fixed with internal rigid fixation (IRF) treated or not with IR laser (λ780 nm, 50 mW, 4 × 4 J/cm(2) = 16 J/cm(2), ϕ = 0.5 cm(2), CW) associated or not to the use of hydroxyapatite and guided bone regeneration (GBR). Surgical tibial fractures were created under general anesthesia on 15 rabbits that were divided into five groups, maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libitum. The fractures in groups II, III, IV and V were fixed with miniplates. Animals in groups III and V were grafted with hydroxyapatite and GBR technique used. Animals in groups IV and V were irradiated at every other day during 2 weeks (4 × 4 J/cm(2), 16 J/cm(2) = 112 J/cm(2)). Observation time was that of 30 days. After animal death, specimens were taken and kept in liquid nitrogen and used for Raman spectroscopy. Raman spectroscopy showed significant differences between groups (p < 0.001). Basal readings showed mean value of 1,234 ± 220.1. Group internal rigid fixation + biomaterial + laser showed higher readings (3,521 ± 2,670) and group internal rigid fixation + biomaterial the lowest (212.2 ± 119.8). In conclusion, the results of the present investigation are important clinically as spectral analysis of bone component evidenced increased levels of CHA on fractured sites by using the association of laser light to a ceramic graft.

  1. Sex assessment from the acetabular rim by means of image analysis.

    PubMed

    Benazzi, S; Maestri, C; Parisini, S; Vecchi, F; Gruppioni, G

    2008-08-25

    Determining sex from skeletal remains is one of the most important steps in archaeological and forensic anthropology. The present study considers the diagnostic value of the acetabulum based on its planar image and related metric data. For this purpose, 83 adult os coxae of known age were examined. Digital photos of the acetabular area were taken, with each bone in a standardized orientation. Technical drawing software was used to trace the acetabular rim and to measure the related dimensions (area, perimeter, longitudinal and transverse maximum width). The measurements were subjected to SPSS discriminant and classification function analysis. There were significant differences (p

  2. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products.

  3. Revision of complex acetabular defects using cages with the aid of rapid prototyping.

    PubMed

    Li, Huiwu; Wang, Liao; Mao, Yuanqing; Wang, You; Dai, Kerong; Zhu, Zhenan

    2013-12-01

    This study details a method using rapid prototyping (RP) technique to assist in acetabular revision with complex bone defects. Hemi-pelvic RP models were built among 25 patients with complex acetabular bone defects. Each patient was scheduled to undergo revision using either commercially available or customized cages based on individualized RP models. Average follow-up was 4.4 years (range, 1 to 9 years). The average Harris hip score was 36.1 (range, 20 to 58) preoperatively and reached an average of 82.6 (range, 60-96) at the last follow-up. No mechanical failure or loosening was observed. One patient experienced hip dislocation 4 days postoperatively. The resultant findings of this study merit consideration of RP as a helpful clinical complement for dealing with some complex bone defect of acetabulum.

  4. Skull fracture

    MedlinePlus

    ... compress the underlying brain tissue (subdural or epidural hematoma). A simple fracture is a break in the bone without damage ... Causes of skull fracture can include: Head trauma Falls, automobile accidents, physical assault, and sports

  5. Rib Fractures

    MedlinePlus

    ... From Brain Injury Additional Content Medical News Rib Fractures By Thomas G. Weiser, MD, MPH, Department of ... Hemothorax Injury to the Aorta Pulmonary Contusion Rib Fractures Tension Pneumothorax Traumatic Pneumothorax (See also Introduction to ...

  6. Hand Fractures

    MedlinePlus

    ... Thumb Arthritis Thumb Sprains Trigger Finger Tumors Wrist Fracture Hand Safety Fireworks Safety Lawnmower Safety Snowblower safety ... Tunnel Ganglion Cysts Thumb Arthritis Trigger Finger Wrist Fracture Hand Safety Fireworks Safety Lawnmower Safety Snowblower safety ...

  7. Total hip arthroplasty with minimal invasive surgery in elderly patients with neck of femur fractures: our institutional experience.

    PubMed

    Bel, Jean-Christophe; Carret, Jean-Paul

    2015-01-01

    The purpose of this study was to investigate whether minimal invasive surgery (MIS) in elderly patients with neck of femur fractures would reduce the peri-operative complications and improve the post-operative ambulation and length of hospital stay in his cohort of patients. Forty elderly patients were treated with either total hip arthroplasty (THA) or bipolar prosthesis using MIS transgluteal approach. A matched reference group treated with a conventional surgical approach formed the control group. All procedures were performed by the same surgeon. Selection of acetabular component included Novae® uncemented press fit dual mobility concept socket or Bipolar Hemi-Arthroplasty (BHA). The femoral implant was Corail® uncemented stem or Fjord® cemented stem when primary instability was encountered. The follow-up was done for all patients and its minimum length was more than thirty-six months. The average length of the skin incision was 7 (6-8) SD 0.7 cm. Eighteen THA, twenty-two BHA, thirty-seven uncemented femoral stems and three cemented stems were implemented. The length of the procedure was the same as those of the reference group. The operative and post-operative blood loss and analgesic use were significantly decreased in the MIS group. Radiographic implants positioning was similar amongst the two groups. No skin complication, no primary infection, no death within ninety days and no dislocations were observed. MIS approach for implanting THA after a femoral neck fracture in the elderly appears to be a reliable procedure.

  8. Damage evolution in acetabular replacements under long-term physiological loading conditions.

    PubMed

    Wang, J-Y; Heaton-Adegbile, P; New, A; Hussell, J G; Tong, J

    2009-05-29

    Damage development in cemented acetabular replacements has been studied in bovine pelvic bones under long-term physiological loading conditions, including normal walking, stair climbing and a combined block loading with representative routine activities. The physiological loading conditions were achieved using a specially designed hip simulator for fixation endurance testing. Damage was detected and monitored using micro-CT scanning at regular intervals of the experiments, and verified by microscopic studies post testing. The results show that debonding at the bone-cement interface defined the failure of cement fixation in all cases, and debondings initiated near the dome of the acetabulum in the superior-posterior quadrant, consistent with the high-stress region identified from the finite element analysis of implanted acetabular models Zant, N.P., Heaton-Adegbile, P., Hussell, J.G., Tong, J., 2008b. In-vitro fatigue failure of cemented acetabular replacements-a hip simulator study. Journal of Biomechanical Engineering, Transactions of the ASME, 130, 021019-1-9]; [Tong, J., Zant, N.P., Wang, J-Y., Heaton-Adegbile, P., Hussell, J.G., 2008. Fatigue in cemented acetabulum. International Journal of Fatigue, 30(8), 1366-1375].

  9. Clinical and Radiological Results over the Medium Term of Isolated Acetabular Revision

    PubMed Central

    Andreani, Lorenzo; Bonicoli, Enrico; Niccolai, Francesco; Lisanti, Michele

    2014-01-01

    Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60) of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32). 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1%) showed thigh pain and only 4 hips (12.11%) presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results. PMID:25610894

  10. Postural correction reduces hip pain in adult with acetabular dysplasia: a case report

    PubMed Central

    Lewis, Cara L.; Khuu, Anne; Marinko, Lee

    2015-01-01

    Developmental dysplasia of the hip is often diagnosed in infancy, but less severe cases of acetabular dysplasia are being detected in young active adults. The purpose of this case report is to present a non-surgical intervention for a 31-year-old female with mild acetabular dysplasia and an anterior acetabular labral tear. The patient presented with right anterior hip and groin pain, and she stood with the trunk swayed posterior to the pelvis (swayback posture). The hip pain was reproduced with the anterior impingement test. During gait, the patient maintained the swayback posture and reported 6/10 hip pain. Following correction of the patient’s posture, the patient’s pain rating was reduced to a 2/10 while walking. The patient was instructed to maintain the improved posture. At the 1 year follow-up, she demonstrated significantly improved posture in standing and walking. She had returned to recreational running and was generally pain-free. The patient demonstrated improvement on self-reported questionnaires for pain, function and activity. These findings suggest that alteration of posture can have an immediate and lasting effect on hip pain in persons with structural abnormality and labral pathology. PMID:25731688

  11. Articular cartilage friction increases in hip joints after the removal of acetabular labrum.

    PubMed

    Song, Yongnam; Ito, Hiroshi; Kourtis, Lampros; Safran, Marc R; Carter, Dennis R; Giori, Nicholas J

    2012-02-02

    The acetabular labrum is believed to have a sealing function. However, a torn labrum may not effectively prevent joint fluid from escaping a compressed joint, resulting in impaired lubrication. We aimed to understand the role of the acetabular labrum in maintaining a low friction environment in the hip joint. We did this by measuring the resistance to rotation (RTR) of the hip, which reflects the friction of the articular cartilage surface, following focal and complete labrectomy. Five cadaveric hips without evidence of osteoarthritis and impingement were tested. We measured resistance to rotation of the hip joint during 0.5, 1, 2, and 3 times body weight (BW) cyclic loading in the intact hip, and after focal and complete labrectomy. Resistance to rotation, which reflects articular cartilage friction in an intact hip was significantly increased following focal labrectomy at 1-3 BW loading, and following complete labrectomy at all load levels. The acetabular labrum appears to maintain a low friction environment, possibly by sealing the joint from fluid exudation. Even focal labrectomy may result in increased joint friction, a condition that may be detrimental to articular cartilage and lead to osteoarthritis.

  12. Impact of Sagittal Balance on Clinical Outcomes in Surgically Treated T12 and L1 Burst Fractures: Analysis of Long-Term Outcomes after Posterior-Only and Combined Posteroanterior Treatment

    PubMed Central

    Ortmaier, R.; Koller, H.; Koller, J.; Hitzl, W.; Auffarth, A.; Resch, H.; von Keudell, A.

    2017-01-01

    Objective. Long-term radiological and clinical outcome retrospective study of surgical treatment for T12 and L1 burst fractures in perspective of sagittal balance measures. Methods. Patients with age of 16–60 years, complete radiographs, early surgical treatment surgery, and follow-up (F/U) > 18 months were included and strict exclusion criteria applied. Regional and thoracolumbar kyphosis angles (RKA and TLA) were measured preoperatively and at final F/U, as were parameters of the spinopelvic sagittal alignment. Clinical outcomes were assessed using validated measures. Results. 36 patients with age mean age of 39 years and F/U of 69 months were included. 61% of patients were treated with bisegmental posterior instrumentation (POST-I) and 39% with combined posteroanterior instrumented fusion (PA-F). At F/U, several indicators for clinical outcomes showed a significant correlation with radiographic measures in the overall cohort with inferior clinical outcomes corresponding with increasing residual deformity and sagittal malalignment. Statistical analysis failed to reach level of significance for the differences between POST-I and PA-F group at final F/U. Only a strong trend towards better restoration of the thoracolumbar alignment was observed for the PA-F group in terms of the RKA and TLA. Conclusions. Results in a surgically treated cohort of T12 and L1 burst fracture patients indicate that superior clinical outcomes depend on restoration of sagittal alignment. PMID:28164114

  13. Facial fractures.

    PubMed Central

    Carr, M. M.; Freiberg, A.; Martin, R. D.

    1994-01-01

    Emergency room physicians frequently see facial fractures that can have serious consequences for patients if mismanaged. This article reviews the signs, symptoms, imaging techniques, and general modes of treatment of common facial fractures. It focuses on fractures of the mandible, zygomaticomaxillary region, orbital floor, and nose. Images p520-a p522-a PMID:8199509

  14. Characterization of Human Anterosuperior Acetabular Depression in Correlation With Labral Tears

    PubMed Central

    Kopydlowski, Nathan J.; Tannenbaum, Eric P.; Smith, Matthew V.; Sekiya, Jon K.

    2014-01-01

    Background: Labral tears often occur in the same quadrant of the acetabulum at a small depression previously referred to as the psoas valley. Understanding the anatomic variations of this depression could help us understand the etiology of labral tears. Purpose: To describe the location and dimensions of the depression located in the anterosuperior acetabular rim. The hypothesis was that the location of this depression would be consistent with the common location of acetabular labral tears described in the literature. Study Design: Controlled laboratory study. Methods: A total of 240 pelvic specimens were divided into 2 groups (n = 120 for each) according to age (younger age group: 21.36 ± 3.12 years [range, 14-24 years]; older age group: 42.30 ± 10.27 years, [range, 25-60 years]).Specimens were also categorized based on sex (mean age: 31.93 ± 12.31 years [male]; 32.08 ± 13.66 years [female]) and race (mean age: 31.45 ± 13.16 years [black]; 32.57 ± 12.82 years [white]). The depth and width of the acetabular depression were measured using a digital caliper, and the location was measured using a goniometer. Results: The psoas valley was observed in every specimen and was located in the anterosuperior quadrant of the acetabulum. Its depth was significantly greater (P < .001) in males (5.35 ± 1.60 mm) than in females (3.95 ± 1.31 mm). The width of the psoas valley was also greater (P < .001) in males (29.39 ± 3.98 mm) than in females (24.49 ± 4.80 mm). There were no differences in size or location of the depression between races or age groups. The psoas valley was located between 3.92 ± 0.42 o’clock anteriorly and 2.12 ± 0.77 o’clock posteriorly. Conclusion: The differences observed in the study data are believed to be a result of the different anatomic morphologies of the pelvis in males and females. This loss of bony support, caused by the depression, could be the underlying cause of weakening of the acetabular labrum as people age. Clinical Relevance

  15. Staged treatment of pilon fractures

    PubMed Central

    Deivaraju, Chenthuran; Vlasak, Richard; Sadasivan, Kalia

    2015-01-01

    Aim To evaluate outcomes following staged anterolateral plating of pilon fractures. Methods Over a 5 year period, patients with pilon fractures received four treatment regimens (staged anterolateral plating, staged medial plating, definitive external fixation, early total care). We defined five outcomes (reduction, soft tissue complications, infection, non-union, malunion) and assessed the outcome of fractures treated by these interventions. Results Staged anterolateral plating or staged medial plating achieved comparable reduction and soft tissue complications. Staged medial plating had higher infection rates, malunion and non-union rates. Conclusions Staged anterolateral plating is superior to staged medial plating in the management of pilon fractures. PMID:26719618

  16. Bipartite patella fracture.

    PubMed

    Canizares, George H; Selesnick, F Harlan

    2003-02-01

    Bipartite patella fracture is an uncommon injury that has rarely been described in the literature. It can be quite debilitating in the competitive athlete and is often overlooked by the treating physician. A bone scan can be helpful in confirming the diagnosis, and appropriate treatment often results in a successful outcome.

  17. [Analysis of migration of screwed acetabular components following revision arthroplasty of the hip joint. Results of single-image roentgen analysis].

    PubMed

    Dihlmann, S W; Ochsner, P E; Pfister, A; Mayrhofer, P

    1994-01-01

    Out of 57 revised acetabular components, which were regularly checked, 47 had been replaced by a cemented Müller's acetabular reinforcement ring resp. a cementless Müller's Sl-shell with flange. Both types of cups are anchored in the acetabular roof with cancellous bone screws (tab. 1). 42 cases with radiograph series permitted a detailed analysis with the EBRA-method, a computer aided method for the evaluation of acetabular spatial migration based on standard radiographs of the pelvis. The clinical results were very satisfying (tab. 6). The screwed acetabular components migrated little, although, some essential displacements of the center of rotation (in relation to the anatomical position) had to be accepted. As was recognizable with today's inaccurate methods of measuring the center of the head, the displacement too far towards cranial influenced the migration tendency less than an excessive lateralisation. Especially satisfying is the fact, that no increased migration was observed after reconstruction bone grafting of severe acetabular defects, provided that at least a partly direct contact between the acetabular component and the original bone stock was obtained. For the first time EBRA shall be introduced here as a method which shows the migration and the spatial inclination of the acetabular cup in a vector chart.

  18. Distal clavicle fractures in children☆

    PubMed Central

    Labronici, Pedro José; da Silva, Ricardo Rodrigues; Franco, Marcos Vinícius Viana; Labronici, Gustavo José; Pires, Robinson Esteves Santos; Franco, José Sergio

    2015-01-01

    Objective To analyze fractures of the distal clavicle region in pediatric patients. Methods Ten patients between the ages of five to eleven years (mean of 7.3 years) were observed. Nine patients were treated conservatively and one surgically. All the fractures were classified using the Nenopoulos classification system. Results All the fractures consolidated without complications. Conservative treatment was used for nine patients, of whom three were in group IIIB, three IIb, two IIa and one IV. The only patient who was treated surgically was a female patient of eleven years of age with a group IV fracture. Conclusion The treatment indication for distal fractures of the clavicle in children should be based on the patient's age and the displacement of the fragments. PMID:26962489

  19. [Treatment of hip fractures in elderly patients].

    PubMed

    Hack, Juliana; Bliemel, Christopher; Ruchholtz, Steffen; Bücking, Benjamin

    2015-04-01

    Hip fractures are among the most common fractures in elderly people. The annual number of femoral fractures is even expected to increase because of an aging society. Due to the high number of comorbidities, there are special challenges in treating geriatric hip fracture patients, which require a multidisciplinary management. This includes surgical treatment allowing full weight bearing in the immediate postoperative period, osteoporosis treatment and falls prevention as well as an early ortho-geriatric rehabilitation program.

  20. Minimally invasive osteosynthesis technique for articular fractures.

    PubMed

    Beale, Brian S; Cole, Grayson

    2012-09-01

    Articular fractures require accurate reduction and rigid stabilization to decrease the chance of osteoarthritis and joint dysfunction. Articular fractures have been traditionally repaired by arthrotomy and internal fixation. Recently, minimally invasive techniques have been introduced to treat articular fractures, reducing patient morbidity and improving the accuracy of reduction. A variety of techniques, including distraction, radiographic imaging, and arthroscopy, are used with the minimally invasive osteosynthesis technique of articular fractures to achieve a successful repair and outcome.

  1. Impending rupture of saphenous vein graft aneurysm with floating fractured bare metal stent treated by coil embolization and covered stent implantation.

    PubMed

    Kodama, Atsuko; Kurita, Tairo; Kato, Osamu; Suzuki, Takahiko

    2016-11-01

    Aneurysmal degeneration of a saphenous vein graft (SVG) is a rare, but potentially fatal complication of coronary artery bypass graft (CABG) surgery. In this case report, a patient that had undergone prior CABG surgery and bare metal stent (BMS) implantation at the site of a stenotic SVG lesion presented at our hospital with chest pain, and an SVG aneurysm was detected at the previous BMS implantation site. In addition, the implanted BMS was fractured and floating in the SVG aneurysm. The SVG aneurysm was successfully occluded by percutaneous intervention, using a combination of distal covered stent deployment at the site of the anastomosis between the native coronary artery and the SVG and proximal coil embolization of the aneurysm.

  2. Prevention of hip fractures.

    PubMed

    Meunier, P J

    1993-11-30

    For a 50-year old Caucasian woman today, the risk of a hip fracture over her remaining life-time is about 17%. Tomorrow the situation will clearly be worse because the continuous increase in life expectancy will cause a three-fold increase in worldwide fracture incidence over the next 60 years. Through diagnostic bone mass measurements at the hip and assessment of biochemical parameters, a great deal has been learned in recent years about reduction of hip fracture risk. Preventive strategies are based on prevention of falls, use of hip protectors, and prevention of bone fragility. The latter includes the optimization of peak bone mass during childhood, postmenopausal estrogen replacement therapy, and also late prevention consisting in reversing senile secondary hyperparathyroidism, which plays an important role in the decrease of skeletal strength. This secondary hyperparathyroidism, which results from both vitamin D insufficiency and low calcium intake, is preventable with vitamin D3 and calcium supplements. They have recently been shown capable of providing effective prevention of hip fractures in elderly women living in nursing homes, with a reduction of about 25% in the number of hip fractures noted in a 3-year controlled study in 3,270 women (intention-to-treat analysis). In conclusion, it is never too early to reduce the risk of osteoporosis and never too late to prevent hip fractures.

  3. What is the Fate of Total Hip Arthroplasty (THA) Acetabular Component Orientation When Evaluated in the Standing Position?

    PubMed

    Tiberi, John V; Antoci, Valentin; Malchau, Henrik; Rubash, Harry E; Freiberg, Andrew A; Kwon, Young-Min

    2015-09-01

    This retrospective study measured the change of the acetabular component orientation between supine and standing radiographs in 113 THA patients and identified the associated anatomical parameters that may help direct pre-operative planning. The mean change of the acetabular component inclination and version from supine to standing was 4.6° and 5.9° respectively (P<0.0001), with 49 (43%) hips showing inclination change >5° and 69 (53%) hips showing version change >5°. Twelve (43%) of 28 'malpositioned' cups became 'well-positioned' and 26 (31%) of 85 'well-positioned' cups became 'malpositioned' upon standing. Changes in inclination were associated with leg length discrepancy and pelvic obliquity; and changes in version were associated with pelvic tilt and pelvic incidence. Standing position and patient factors should be considered when defining "optimal" acetabular orientation.

  4. Uncemented porous tantalum acetabular components: early follow-up and failures in 613 primary total hip arthroplasties.

    PubMed

    Noiseux, Nicolas O; Long, William J; Mabry, Tad M; Hanssen, Arlen D; Lewallen, David G

    2014-03-01

    Uncemented tantalum acetabular components were introduced in 1997. The purpose was to determine the 2- to 10-year results with this implant material in primary total hip arthroplasty. Our registry identified all primary total hip cases with porous tantalum cups implanted from 1997 to 2004. Clinical outcomes and radiographs were studied. 613 cases were identified. Seventeen percent of patients were lost to follow-up. Twenty-five reoperations were performed (4.4%). Acetabular cup removal occurred in 6 cases (1.2%). No cups were revised for aseptic loosening. Incomplete radiolucent lines were found on 9.3% of initial postoperative radiographs. At 2 years, 67% had resolved. Zero new radiolucent lines were detected. Two- to 10-year results of porous tantalum acetabular components for primary total hip arthroplasty demonstrate high rates of initial stability and apparent ingrowth.

  5. MRI findings following metal on metal hip arthroplasty and their relationship with metal ion levels and acetabular inclination angles.

    PubMed

    Fox, Ciara M; Bergin, Karen M; Kelly, Gabrielle E; McCoy, Gerry F; Ryan, Anthony G; Quinlan, John F

    2014-08-01

    Following the global recall of all ASR metal on metal hip products, our aim was to correlate MRI findings with acetabular inclination angles and metal ion levels in patients with these implants. Both cobalt and chromium levels were significantly higher in the presence of a periprosthetic fluid collection. There was no association between the presence of a periprosthetic mass, bone marrow oedema, trochanteric bursitis or greater levels of abductor muscle destruction for cobalt or chromium. There was no association between the level of periprosthetic tissue reaction and the acetabular inclination angle with any of the pathologies identified on MRI. The relationship between MRI pathology, metal ion levels and acetabular inclination angles in patients with ASR implants remains unclear adding to the complexity of managing patients.

  6. Fracture pain-Traveling unknown pathways.

    PubMed

    Alves, Cecília J; Neto, Estrela; Sousa, Daniela M; Leitão, Luís; Vasconcelos, Daniel M; Ribeiro-Silva, Manuel; Alencastre, Inês S; Lamghari, Meriem

    2016-04-01

    An increase of fracture incidence is expected for the next decades, mostly due to the undeniable increase of osteoporotic fractures, associated with the rapid population ageing. The rise in sports-related fractures affecting the young and active population also contributes to this increased fracture incidence, and further amplifies the economical burden of fractures. Fracture often results in severe pain, which is a primary symptom to be treated, not only to guarantee individual's wellbeing, but also because an efficient management of fracture pain is mandatory to ensure proper bone healing. Here, we review the available data on bone innervation and its response to fracture, and discuss putative mechanisms of fracture pain signaling. In addition, the common therapeutic approaches to treat fracture pain are discussed. Although there is still much to learn, research in fracture pain has allowed an initial insight into the mechanisms involved. During the inflammatory response to fracture, several mediators are released and will putatively activate and sensitize primary sensory neurons, in parallel, intense nerve sprouting that occurs in the fracture callus area is also suggested to be involved in pain signaling. The establishment of hyperalgesia and allodynia after fracture indicates the development of peripheral and central sensitization, still, the underlying mechanisms are largely unknown. A major concern during the treatment of fracture pain needs to be the preservation of proper bone healing. However, the most common therapeutic agents, NSAIDS and opiates, can cause significant side effects that include fracture repair impairment. The understanding of the mechanisms of fracture pain signaling will allow the development of mechanisms-based therapies to effectively and safely manage fracture pain.

  7. Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population

    PubMed Central

    Xiao, Jian-Lin; Zuo, Jian-Lin; Liu, Peng; Qin, Yan-Guo; Li, Xue-Zhou; Liu, Tong; Gao, Zhong-Li

    2015-01-01

    Background: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. Methods: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. Results: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. Conclusions: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better. PMID:26063357

  8. The efficacy of the use of IR laser phototherapy associated to biphasic ceramic graft and guided bone regeneration on surgical fractures treated with wire osteosynthesis: a comparative laser fluorescence and Raman spectral study on rabbits.

    PubMed

    Pinheiro, Antônio Luiz Barbosa; Santos, Nicole Ribeiro Silva; Oliveira, Priscila Chagas; Aciole, Gilberth Tadeu Santos; Ramos, Thais Andrade; Gonzalez, Tayná Assunção; da Silva, Laís Nogueira; Barbosa, Artur Felipe Santos; Silveira, Landulfo

    2013-05-01

    The aim of the present study was to assess, by Raman spectroscopy and laser fluorescence, the repair of surgical fractures fixed with wire osteosynthesis treated or not with infrared laser (λ780 nm, 50 mW, 4 × 4 J/cm(2) =16 J/cm(2), ϕ=0.5 cm(2), CW) associated or not to the use of hydroxyapatite and guided bone regeneration. Surgical tibial fractures were created under general anesthesia on 15 rabbits that were divided into five groups, maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet, and had water ad libitum. The fractures in groups II, III, IV, and V were fixed with wires. Animals in groups III and V were grafted with hydroxyapatite (HA) and guided bone regeneration (GBR) technique used. Animals in groups IV and V were irradiated at every other day during 2 weeks (4 × 4 J/cm(2), 16 J/cm(2) =112 J/cm(2)). Observation time was that of 30 days. After animal death, specimens were taken and kept in liquid nitrogen and used for Raman spectroscopy. The Raman results showed basal readings of 1,234.38 ± 220. Groups WO+B+L showed higher readings (1,680.22 ± 822) and group WO+B the lowest (501.425 ± 328). Fluorescence data showed basal readings of 5.83333 ± 0.7. Groups WO showed higher readings (6.91667 ± 0.9) and group WO+B+L the lowest (1.66667 ± 0.5). There were significant differences between groups on both cases (p<0.05). Pearson correlation was negative and significant (R (2)   = -0.60; p<0.001), and it was indicative that, when the Raman peaks of calcium hydroxyapatite (CHA) are increased, the level of fluorescence is reduced. It is concluded that the use of near-infrared lasertherapy associated to HA graft and GBR was effective in improving bone healing on fractured bones as a result of the increasing deposition of CHA measured by Raman spectroscopy and decrease of the organic components as shown by the fluorescence readings.

  9. [A histopathological study on aging process of the acetabulum with special reference to the pathogenesis of the acetabular cyst (author's transl)].

    PubMed

    Itoigawa, Y; Azuma, H; Kako, K

    1980-03-01

    This is to report the aging process of the acetabula studied as an aid to the investigation of the pathogenesis and progression of osteoarthritis of the acetabulum. The material consisted of 45 acetabula obtained from 45 fresh cadavers. Regarding the morphological changes of the labrum-cartilage junction of middle and old age groups, marked degenerative changes such as tear, detachment, fissuring and scar formation were observed in many cases at the loaded part of the acetabulum. Among these, a loose connective tissue had invaded into the subchondral space through a fissure in one case, and infusion of the joint fluid into a fissure was observed in another. All of the 3 acetabular cysts were from the middle and old age groups and at the weight-bearing portions of the acetabula. All cysts were found to have communication with the joint cavities through the fissures. The trabeculae surrounding the cysts showed slight destructive changes apparently due to compression by the cysts. The above findings would suggest that the cyst formation as an aging process at the weight-bearing portions is probably due to infusion of the joint fluid into the subchondral space through the fissure at the labrum-cartilage junction or through the fissure at the junction resulting from subchondral plate fracture, although some additional causative factors might also play a role in the process.

  10. [Ceramic acetabular cups for hip endoprostheses. 7: How do position of the center of rotation and the CCD angle of the shaft modify range of motion and impingement?].

    PubMed

    Bader, R; Willmann, G

    1999-12-01

    The range of motion (ROM) of total hip prostheses is influenced by a number of parameters. An insufficient ROM may cause impingement, which may result in subluxation, dislocation or material failure of the prostheses. In a three-dimensional CAD simulation, the position of the centre of rotation and the CCD angle of the stem were investigated. Displacement of the centre of rotation of the femoral head may be due to wear (PE cups) or to the design of the prosthesis (ceramic cups). Stems of widely differing design have been developed and implanted. The results of the present study demonstrate that the ROM is clearly reduced by increasing penetration of the femoral head. At an inclination angle of 45 degrees, a depth of penetration of 2 mm restricts flexion by about 15 degrees, and a depth of penetration of 3 mm by about 30 degrees. At smaller angles of inclination the ROM is reduced and flexion and abduction are associated with an increased risk of impingement. With steeper acetabular cup inclinations, the risk of impingement decreases, but dislocation, the risk of rim fractures (ceramic cups), and wear and penetration rates (PE cups) increase. The CCD angle of the stem should be oriented to the anatomical situation. At high CCD angles (> 135 degrees), flexion is clearly limited, in particular when there is penetration of the femoral head. For modern total hip arthroplasty, prosthetic systems characterised by precise positioning of components, minimum wear, slightly recessed inserts, and appropriate CCD angles should be used.

  11. Functional outcomes and cost estimation for extra-articular and simple intra-articular distal radius fractures treated with open reduction and internal fixation versus closed reduction and percutaneous Kirschner wire fixation

    PubMed Central

    Dzaja, Ivan; MacDermid, Joy C.; Roth, James; Grewal, Ruby

    2013-01-01

    Background We sought to compare direct costs and clinical and radiographic outcomes for distal radius fractures (DRF) treated with open reduction internal fixation with volar locking plates (VLP) versus closed reduction and percutaneous pinning (CRPP). Methods We identified patients with AO-type A and C1 DRFs from a prospective database. Outcomes were assessed at 6 weeks and at 3, 6 and 12 months, and surgical care costs were estimated. Results Twenty patients were treated with CRPP and 24 with VLP. There were no significant differences in patient-rated wrist evaluation (PRWE) scores between the 2 groups at any time point (mean 16.2 ± 23.1 in the CRPP group v. 21.5 ± 23.6 in the VLP group, p = 0.91). Overall alignment was maintained in both groups; however, there was a greater loss of radial height over time with CRPP than VLP (0.97 mm v. 0.25 mm, p = 0.018). The mean duration of surgery was longer for VLP than CRPP (113.9 ± 39.5 min v. 86.5 ± 7.8 min, p = 0.029), but there were fewer clinic visits (5.2 ± 1.4 v. 7.8 ± 1.3, p < 0.001) and fewer radiographs (7.4 ± 2.7 v. 9 ± 2.4, p = 0.031). The total cost per case was greater for VLP than CRPP ($1637.27 v. $733.91). Conclusion Based on PRWE scores, VLPs did not offer any significant advantage over CRPP in patients with simple fracture types between 3 and 12 months, but they were much more costly. Whether VLP offers any functional advantage earlier in recovery, thereby justifying their expense, requires further investigation in the form of a prospective randomized trial with a detailed cost analysis. PMID:24284144

  12. Fractures of the cervical spine

    PubMed Central

    Marcon, Raphael Martus; Cristante, Alexandre Fogaça; Teixeira, William Jacobsen; Narasaki, Douglas Kenji; Oliveira, Reginaldo Perilo; de Barros Filho, Tarcísio Eloy Pessoa

    2013-01-01

    OBJECTIVES: The aim of this study was to review the literature on cervical spine fractures. METHODS: The literature on the diagnosis, classification, and treatment of lower and upper cervical fractures and dislocations was reviewed. RESULTS: Fractures of the cervical spine may be present in polytraumatized patients and should be suspected in patients complaining of neck pain. These fractures are more common in men approximately 30 years of age and are most often caused by automobile accidents. The cervical spine is divided into the upper cervical spine (occiput-C2) and the lower cervical spine (C3-C7), according to anatomical differences. Fractures in the upper cervical spine include fractures of the occipital condyle and the atlas, atlanto-axial dislocations, fractures of the odontoid process, and hangman's fractures in the C2 segment. These fractures are characterized based on specific classifications. In the lower cervical spine, fractures follow the same pattern as in other segments of the spine; currently, the most widely used classification is the SLIC (Subaxial Injury Classification), which predicts the prognosis of an injury based on morphology, the integrity of the disc-ligamentous complex, and the patient's neurological status. It is important to correctly classify the fracture to ensure appropriate treatment. Nerve or spinal cord injuries, pseudarthrosis or malunion, and postoperative infection are the main complications of cervical spine fractures. CONCLUSIONS: Fractures of the cervical spine are potentially serious and devastating if not properly treated. Achieving the correct diagnosis and classification of a lesion is the first step toward identifying the most appropriate treatment, which can be either surgical or conservative. PMID:24270959

  13. Comparative Prospective Study of Load Distribution Projection Among Patients with Vertebral Fractures Treated with Percutaneous Vertebroplasty and a Control Group of Healthy Volunteers

    SciTech Connect

    Kelekis, Alexios Filippiadis, Dimitrios K. Vergadis, Chrysovalantis Tsitskari, Maria Nasis, Nikolaos Malagari, Aikaterini Kelekis, Nikolaos

    2013-04-12

    PurposeThrough a prospective comparison of patients with vertebral fractures and normal population, we illustrate effect of percutaneous vertebroplasty (PV) upon projection of load distribution changes.MethodsVertebroplasty group (36 symptomatic patients with osteoporotic vertebral fractures) was evaluated on an electronic baropodometer registering projection of weight bearing areas on feet. Load distribution between right and left foot (including rear-front of the same foot) during standing and walking was recorded and compared before (group V1) and the day after (group V2) PV. Control group (30 healthy asymptomatic volunteers-no surgery record) were evaluated on the same baropodometer.ResultsMean value of load distribution difference between rear-front of the same foot was 9.45 ± 6.79 % (54.72–45.28 %) upon standing and 14.76 ± 7.09 % (57.38–42.62 %) upon walking in the control group. Respective load distribution values before PV were 16.52 ± 11.23 and 30.91 ± 19.26 % and after PV were 10.08 ± 6.26 and 14.25 ± 7.68 % upon standing and walking respectively. Mean value of load distribution variation between the two feet was 6.36 and 14.6 % before and 4.62 and 10.4 % after PV upon standing and walking respectively. Comparison of load distribution variation (group V1–V2, group V1-control group) is statistically significant. Comparison of load distribution variation (group V2-control group) is not statistically significant. Comparison of load distribution variation among the two feet is statistically significant during walking but not statistically significant during standing.ConclusionsThere is a statistically significant difference when comparing load distribution variation prior vertebroplasty and that of normal population. After vertebroplasty, this difference normalizes in a statistically significant way. PV is efficient on equilibrium-load distribution improvement as well.

  14. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    PubMed

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing.

  15. Current concept in dysplastic hip arthroplasty: Techniques for acetabular and femoral reconstruction

    PubMed Central

    Bicanic, Goran; Barbaric, Katarina; Bohacek, Ivan; Aljinovic, Ana; Delimar, Domagoj

    2014-01-01

    Adult patients with developmental dysplasia of the hip develop secondary osteoarthritis and eventually end up with total hip arthroplasty (THA) at younger age. Because of altered anatomy of dysplastic hips, THA in these patients represents technically demanding procedure. Distorted anatomy of the acetabulum and proximal femur together with conjoined leg length discrepancy present major challenges during performing THA in patients with developmental dysplasia of the hip. In addition, most patients are at younger age, therefore, soft tissue balance is of great importance (especially the need to preserve the continuity of abductors) to maximise postoperative functional result. In this paper we present a variety of surgical techniques available for THA in dysplastic hips, their advantages and disadvantages. For acetabular reconstruction following techniques are described: Standard metal augments (prefabricated), Custom made acetabular augments (3D printing), Roof reconstruction with vascularized fibula, Roof reconstruction with pedicled iliac graft, Roof reconstruction with autologous bone graft, Roof reconstruction with homologous bone graft, Roof reconstruction with auto/homologous spongious bone, Reinforcement ring with the hook in combination with autologous graft augmentation, Cranial positioning of the acetabulum, Medial protrusion technique (cotyloplasty) with chisel, Medial protrusion technique (cotyloplasty) with reaming, Cotyloplasty without spongioplasty. For femoral reconstruction following techniques were described: Distraction with external fixator, Femoral shortening through a modified lateral approach, Transtrochanteric osteotomies, Paavilainen osteotomy, Lesser trochanter osteotomy, Double-chevron osteotomy, Subtrochanteric osteotomies, Diaphyseal osteotomies, Distal femoral osteotomies. At the end we present author’s treatment method of choice: for acetabulum we perform cotyloplasty leaving only paper-thin medial wall, which we break during

  16. The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation.

    PubMed

    Dickinson, A S; Taylor, A C; Browne, M

    2012-02-23

    Acetabular cup loosening is a late failure mode of total hip replacements, and peri-prosthetic bone deterioration may promote earlier failure. Preservation of supporting bone quality is a goal for implant design and materials selection, to avoid stress shielding and bone resorption. Advanced polymer composite materials have closer stiffness to bone than metals, ceramics or polymers, and have been hypothesised to promote less adverse bone adaptation. Computer simulations have supported this hypothesis, and the present study aimed to verify this experimentally. A composite hemi-pelvis was implanted with Cobalt Chromium (CoCr), polyethylene (UHMWPE) and MOTIS(®)carbon-fibre-reinforced polyether etherketone (CFR-PEEK) acetabular cups. In each case, load was applied to the implanted pelvis and Digital Image Correlation (DIC) was used for surface strain measurement. The test was repeated for an intact hemi-pelvis. Trends in implanted vs. intact bone principal strains were inspected to assess the average principal strain magnitude change, allowing comparison of the potential bone responses to implantation with the three cups. The CFR-PEEK cup was observed to produce the closest bone strain to the intact hip in the main load path, the superior peri-acetabular cortex (+12% on average, R(2)=0.84), in comparison to CoCr (+40%, R(2)=0.91) and UHWMPE cups (-26%, R(2)=0.94). Clinical observations have indicated that increased periacetabular cortex loading may result in reduced polar cancellous bone loading, leading to longer term losses in periprosthetic bone mineral density. This study provides experimental evidence to verify previous computational studies, indicating that cups produced using materials with stiffness closer to cortical bone recreate physiological cortical bone strains more closely and could, therefore, potentially promote less adverse bone adaptation than stiffer press-fitted implants in current use.

  17. Accuracy of methods to measure femoral head penetration within metal-backed acetabular components.

    PubMed

    Callary, Stuart A; Solomon, Lucian B; Holubowycz, Oksana T; Campbell, David G; Howie, Donald W

    2016-06-30

    A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.

  18. External Fixation combined with Limited Internal Fixation versus Open Reduction Internal Fixation for Treating Ruedi-Allgower Type III Pilon Fractures

    PubMed Central

    Guo, Yongzhi; Tong, Liangyong; Li, Shaoguang; Liu, Zhi

    2015-01-01

    Background The optimal treatment of type III pilon fractures remains controversial. Hence, we performed this study to investigate whether open reduction and internal fixation (ORIF) is superior to external fixations combined with limited internal fixations (EFLIF). Material/Methods From January 2012 to October 2013, a total of 78 patients were included. Twenty-six patients underwent EFLIF and 52 patients underwent ORIF. All subjects were followed up at 1, 3, 6, and 12 months postoperatively. All outcomes and complications were recorded. Results No statistical differences were observed in Mazur score or ROM between the 2 groups. There were significant differences between the 2 groups in hospital stay (P<0.001), reduction results (P=0.019), screw loosening (P=0.025), and traumatic arthritis (P=0.037). Conclusions Similar functional outcomes were achieved in EFLIF and ORIF groups. Due to several limitations of this study, a well-designed randomized controlled trial involving more patients and long-term follow-up is needed to find an optimal treatment protocol. PMID:26050786

  19. Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study.

    PubMed

    Ghosh, Rajesh

    2016-09-01

    The aim of the study is to determine failure of the cemented polyethylene acetabular component, which might occur due to excessive bone resorption, cement-bone interface debonding and fatigue failure of the cement mantle. Three-dimensional finite element models of intact and implanted pelvic bone were developed and bone remodeling algorithm was implemented for present analysis. Soderberg fatigue failure diagram was used for fatigue assessment of the cement mantle. Hoffman failure criterion was considered for prediction of cement-bone interface debonding. Results indicate fatigue failure of the cement mantle and implant-bone interface debonding might not occur due to bone remodeling.

  20. Femoro-acetabular impingement clinical research: is a composite outcome the answer?

    PubMed

    Ayeni, Olufemi R; Sansone, Mikael; de Sa, Darren; Simunovic, Nicole; Bedi, Asheesh; Kelly, Bryan T; Farrokhyar, Forough; Karlsson, Jon

    2016-01-01

    Femoro-acetabular impingement (FAI) is increasingly recognized as an important cause of hip pain in the young adult. However, the methods of evaluating the efficacy of surgical intervention are often not validated and/or inconsistently reported. Important clinical, gait, radiographic and biomarker outcomes are discussed. This article (1) presents the rationale for considering a composite outcome for FAI patients; (2) examines a variety of important end points currently used to evaluate FAI surgery; (3) discusses a strategy to generate a composite outcome by combining these end points; and (4) highlights the challenges and current areas of controversy that such an approach to evaluating symptomatic FAI patients may present.

  1. Percutaneous Vertebroplasty for Osteoporotic Compression Fracture: Multivariate Study of Predictors of New Vertebral Body Fracture

    SciTech Connect

    Komemushi, Atsushi Tanigawa, Noboru; Kariya, Shuji; Kojima, Hiroyuki; Shomura, Yuzo; Komemushi, Sadao; Sawada, Satoshi

    2006-08-15

    Purpose. To investigate the risk factors and relative risk of new compression fractures following vertebroplasty. Methods. Initially, we enrolled 104 consecutive patients with vertebral compression fractures caused by osteoporosis. A total of 83 of the 104 patients visited our hospital for follow-up examinations for more than 4 weeks after vertebroplasty. Logistic regression analysis of the data obtained from these 83 patients was used to determine relative risks of recurrent compression fractures, using 13 different factors. Results. We identified 59 new fractures in 30 of the 83 patients: 41 new fractures in vertebrae adjacent to treated vertebrae; and 18 new fractures in vertebrae not adjacent to treated vertebrae. New fractures occurred in vertebrae adjacent to treated vertebrae significantly more frequently than in vertebrae not adjacent to treated vertebrae. Only cement leakage into the disk was a significant predictor of new vertebral body fracture after vertebroplasty (odds ratio = 4.633). None of the following covariates were associated with increased risk of new fracture: age, gender, bone mineral density, the number of vertebroplasty procedures, the number of vertebrae treated per procedure, the cumulative number of vertebrae treated, the presence of a single untreated vertebra between treated vertebrae, the presence of multiple untreated vertebrae between treated vertebrae, the amount of bone cement injected per procedure, the cumulative amount of bone cement injected, cement leakage into the soft tissue around the vertebra, and cement leakage into the vein.

  2. Comparing Single Versus Double Screw-Rod Anterior Instrumentation for Treating Thoracolumbar Burst Fractures with Incomplete Neurological Deficit: A Prospective, Randomized Controlled Trial

    PubMed Central

    Yu, Yu; Wang, Juan; Shao, Gaohai; Wang, Qunbo; Li, Bo

    2016-01-01

    Background Following a thoracolumbar burst fracture (TCBF), anterior screw-rods apply pressure upon the graft site. However, there is limited evidence comparing single screw-rod anterior instrumentation (SSRAI) to double screw-rod anterior instrumentation (DSRAI) for TCBFs. Our objective was to compare SSRAI versus DSRAI for TCBFs with incomplete neurological deficit. Material/Methods A total of 51 participants with T11-L2 TCBFs (AO classification: A3) were randomly assigned to receive SSRAI or DSRAI. Key preoperative, perioperative, and postoperative data were collected. Statistical analysis was conducted to determine the independent factors associated with inferior clinical outcomes, as well as the comparative efficacy of SSRAI and DSRAI. Results There were no significant differences in the key demographic and clinical characteristics between the two groups (all p>0.05). Smoking status was significantly associated with inferior three-month and six-month Denis pain scores (Wald statistic=4.246, p=0.039). Both SSRAI and DSRAI were significantly effective in improving three-month and six-month postoperative degree of kyphosis, three-month and six-month postoperative ASIA impairment scale scores, three-month and six-month postoperative Denis pain score, and three-month and six-month postoperative Denis work score (all p<0.001). Although there were no significant differences between DSRAI and SSRAI with respect to all outcomes (all p>0.05), DSRAI displayed significantly longer operating times, as well as significantly larger operative blood losses (both p<0.001). Conclusions SSRAI may be preferable over DSRAI for TCBFs with incomplete neurological deficit due to its lower operating time and amount of operative blood loss. PMID:27197020

  3. Ankle fracture - aftercare

    MedlinePlus

    Malleolar fracture; Tri-malleolar; Bi-malleolar; Distal tibia fracture; Distal fibula fracture; Malleolus fracture ... Some ankle fractures may require surgery when: The ends of the bone are out of line with each other (displaced). The ...

  4. Metal-backed acetabular components with conventional polyethylene: a review of 9113 primary components with a follow-up of 20 years.

    PubMed

    Hallan, G; Dybvik, E; Furnes, O; Havelin, L I

    2010-02-01

    The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncemented metal-backed acetabular components. A total of 9113 primary uncemented acetabular components were implanted in 7937 patients between 1987 and 2007. These were included in a prospective, population-based observational study. All the implants were modular and metal-backed with ultra-high-molecular-weight polyethylene liners. The femoral heads were made of stainless steel, cobalt-chrome (CoCr) alloy or alumina ceramic. In all, seven different designs of acetabular component were evaluated by the Kaplan-Meier survivorship method and Cox regression analysis. Most acetabular components performed well up to seven years. When the endpoint was revision of the acetabular component because of aseptic loosening, the survival ranged between 87% and 100% at ten years. However, when the endpoint was revision for any reason, the survival estimates were 81% to 92% for the same implants at ten years. Aseptic loosening, wear, osteolysis and dislocation were the main reasons for the relatively poor overall performance of the acetabular components. Prostheses with alumina heads performed slightly better than those with stainless steel or CoCr alloy in subgroups. Whereas most acetabular components performed well at seven years, the survivorship declined with longer follow-up. Fixation was generally good. None of the metal-backed uncemented acetabular components with ultra-high-molecular-weight polyethylene liners in our study had satisfactory long-term results because of high rates of wear, osteolysis, aseptic loosening and dislocation.

  5. Acetabular Reconstruction with Human and Bovine Freeze- Dried Bone Grafts and a Reinforcement Device

    PubMed Central

    Rosito, Ricardo; Galia, Carlos Roberto; Macedo, Carlos Alberto Souza; Moreira, Luis Fernando; Quaresma, Lourdes Maria Araújo C.; Palma, Humberto Moreira

    2008-01-01

    BACKGROUND This is a cohort trial (1997–2005) of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG) and a reinforcement device. OBJECTIVE To compare clinical/radiographic graft incorporation capability between cancellous bone grafts. PATIENTS/METHODS There were two groups: I (n=26) receiving human grafts and II (n=25) receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d’Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn’s et al. criteria for radiographic bone incorporation. RESULTS No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424). CONCLUSION The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty. PMID:18719763

  6. Preliminary analysis on the MD-4® plasma-sprayed titanium acetabular component☆

    PubMed Central

    de Araújo Loures, Elmano; Simoni, Leandro Furtado; Leite, Isabel Cristina Gonçalves; Loures, Daniel Naya; Loures, Clarice Naya

    2015-01-01

    Objectives To evaluate the short-term performance of a type of implant manufactured in Brazil. Methods This study analyzed a cohort of 60 patients who underwent implantation of MD-4® acetabular components during primary hip arthroplasty procedures performed between January 1, 2010, and August 1, 2012. The patients were studied retrospectively with regard to clinical behavior, stability and radiological osseointegration. The patients were followed up for a minimum of 12 months and a maximum of 42 months (mean: 27) and were evaluated by means of the Harris Hip Score, SF-36 questionnaire and serial conventional radiographs. Results All the components were radiologically stable, without evidence of migration or progressive radiolucency lines. On average, the Harris Hip Score evolved from 36.1 to 92.1 (p < 0.001) and the SF-36 showed significant increases in all its domains (p < 0.001). No differences were observed among patients with osteoarthrosis, osteonecrosis, hip dysplasia or other conditions. Conclusions The short-term results showed clinical and radiological signs of stability and osseointegration of the implants, which may represent a predictive factor regarding medium-term survival of this acetabular component. PMID:26229918

  7. Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear

    PubMed Central

    Looney, R John; Boyd, Allen; Totterman, Saara; Seo, Gwy-Suk; Tamez-Pena, Jose; Campbell, Debbie; Novotny, Leonore; Olcott, Christopher; Martell, John; Hayes, F Ann; O'Keefe, Regis J; Schwarz, Edward M

    2002-01-01

    Osteolysis, which is considered to be a major source of morbidity following total hip joint replacement, has been notoriously difficult to measure accurately, particularly in the acetabular area. In order to study periacetabular osteolysis, specialized software for computerized tomography (CT) scan image analysis has been developed. This software (3D-CT) eliminates metal artifacts, allows three-dimensional segmentation of the CT image, and reconstructs the segmented image to provide an accurate representation and measurement of volume for osteolytic lesions. In the present study, 20 patients underwent periacetabular osteolytic volume determination using 3D-CT, functional assessment (using the Harris Hip Scale, the Western Ontario and McMaster University Osteoarthritis Index, and the short form 36 questionnaire), and two-dimensional analysis of volumetic polyethylene wear using digitalized plain films. Periacetabular osteolysis correlated directly with the polyethylene wear rate (relative risk [RR] = 0.494, P = 0.027). If one patient with an acetabular revision, one patient with recurrent dislocation, and one patient with a Biomet prosthesis are excluded, then the correlation between wear and osteolysis is improved (RR = 0.685, P = 0.002). In summary, the current study demonstrates both the feasibility of CT imaging of periacetabular osteolysis and the correlation between polyethylene wear and osteolytic volume, providing a potential outcome measure for clinical trials that are designed to examine interventions in this complex disease process. PMID:11879538

  8. Towards the optimal design of an uncemented acetabular component using genetic algorithms

    NASA Astrophysics Data System (ADS)

    Ghosh, Rajesh; Pratihar, Dilip Kumar; Gupta, Sanjay

    2015-12-01

    Aseptic loosening of the acetabular component (hemispherical socket of the pelvic bone) has been mainly attributed to bone resorption and excessive generation of wear particle debris. The aim of this study was to determine optimal design parameters for the acetabular component that would minimize bone resorption and volumetric wear. Three-dimensional finite element models of intact and implanted pelvises were developed using data from computed tomography scans. A multi-objective optimization problem was formulated and solved using a genetic algorithm. A combination of suitable implant material and corresponding set of optimal thicknesses of the component was obtained from the Pareto-optimal front of solutions. The ultra-high-molecular-weight polyethylene (UHMWPE) component generated considerably greater volumetric wear but lower bone density loss compared to carbon-fibre reinforced polyetheretherketone (CFR-PEEK) and ceramic. CFR-PEEK was located in the range between ceramic and UHMWPE. Although ceramic appeared to be a viable alternative to cobalt-chromium-molybdenum alloy, CFR-PEEK seems to be the most promising alternative material.

  9. Measuring acetabular component position on lateral radiographs - ischio-lateral method.

    PubMed

    Pulos, Nicholas; Tiberi Iii, John V; Schmalzried, Thomas P

    2011-01-01

    The standard method for the evaluation of arthritis and postoperative assessment of arthroplasty treatment is observation and measurement from plain films, using the flm edge for orientation. A more recent employment of an anatomical landmark, the ischial tuberosity, has come into use as orientation for evaluation and is called the ischio-lateral method. In this study, the use of this method was evaluated as a first report to the literature on acetabular component measurement using a skeletal reference with lateral radiographs. Postoperative radiographs of 52 hips, with at least three true lateral radiographs taken at different time periods, were analyzed. Component position was measured with the historical method (using the flm edge for orientation) and with the new method using the ischio-lateral method. The mean standard deviation (SD) for the historical approach was 3.7° and for the ischio-lateral method, 2.2° (p < 0.001). With the historical method, 19 (36.5%) hips had a SD greater than ± 4°, compared to six hips (11.5%) with the ischio-lateral method. By using a skeletal reference, the ischio-lateral method provides a more consistent measurement of acetabular component position. The high intra-class correlation coefficients for both intra- and inter-observer reliability indicate that the angle measured with this simple method, which employs no further technology, increased time, or cost, is consistent and reproducible for multiple observers.

  10. Vibrational spectroscopy study of the oxidation of Hylamer UHMWPE explanted acetabular cups sterilized differently

    NASA Astrophysics Data System (ADS)

    Reggiani, Matteo; Tinti, Anna; Visentin, Manuela; Stea, Susanna; Erani, Paolo; Fagnano, Concezio

    2007-05-01

    Ultra-high-molecular-weight polyethylene (UHMWPE) has been used for over 40 years for acetabular cups in total hip joint prosthesis. Hylamer is a hot isostatically pressed material with high crystallinity. Early loosening due to extensive oxidation and phase transformation has been observed for this material. To analyze the reasons for its high tendency to oxidize, we have examined by FT-IR spectroscopy explanted acetabular cups γ-sterilized in different ways. The oxidation and wear rate observed were: Hylamer cups γ-sterilized in air with a long shelf life > Hylamer cups γ-sterilized in air with short shelf life ⩾ Hylamer cups γ-sterilized in nitrogen. Our data indicate the important role of the shelf life on the oxidation of the cups: the samples γ-sterilized in air characterized by a shelf life greater than 3 years showed severe oxidation, a high wear rate, and marked debris production with delamination and the formation of a brittle zone in the more oxidated regions. In these regions we observed an increase in crystallinity, which was probably due to the decrease in the molecular weight of PE. The high oxidation was probably due to the modifications induced by the material treatment.

  11. [Distal radius fractures in children].

    PubMed

    Otayek, S; Ramanoudjame, M; Fitoussi, F

    2016-12-01

    Metaphyseal and physeal fractures of the distal radius are common in children. Most cases are best treated with closed reduction and cast immobilization. Long-term outcomes of these injuries are excellent when specific treatment principles of reduction and casting are followed. Surgical indications are limited and include open fractures, intra-articular fractures, non-reducible fractures, unstable fractures, and the presence of associated nerve injury. Closed reduction and percutaneous pin fixation is the most commonly used surgical option. The clinician should be aware of delayed complications such as growth disturbance of the distal radius, and understand how to manage these problems to ensure successful long-term outcomes. Epiphysiodesis is uncommon but growth plate injuries need to be followed for one year.

  12. [Femoral shaft fractures in children].

    PubMed

    Dietz, H-G; Schlickewei, W

    2011-05-01

    Femoral shaft fractures in children represent 1.5% of all fractures in childhood. Up to the age of 4 years, conservative treatment in a hip spica or short-term overhead traction is the therapy of choice. Femoral shaft fractures between the age of 5 and 16 years should be treated surgically. In over 90% of these cases elastic stable intramedullary nailing (ESIN) is the premier treatment option. Additional end caps can be used for unstable fractures and in length discrepancy. The external fixator and the locking plate are reserved for fractures with severe soft tissue injuries, vascular problems and some specific situations mentioned later on. By adhering to these standards good results can be achieved with a low complication rate.

  13. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  14. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  15. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  16. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  17. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  18. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  19. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  20. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  1. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented...

  2. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented...

  3. Foot and ankle fractures in dancers.

    PubMed

    Goulart, Megan; O'Malley, Martin J; Hodgkins, Christopher W; Charlton, Timothy P

    2008-04-01

    Fractures in the dance population are common. Radiography, CT, MRI, and bone scan should be used as necessary to arrive at the correct diagnosis after meticulous physical examination. Treatment should address the fracture itself and any surrounding problems such as nutritional/hormonal issues and training/performance techniques and regimens. Compliance issues in this population are a concern, so treatment strategies should be tailored accordingly. Stress fractures in particular can present difficulties to the treating physician and may require prolonged treatment periods. This article addresses stress fractures of the fibula, calcaneus, navicular, and second metatarsal; fractures of the fifth metatarsal, sesamoids, and phalanges; and dislocation of toes.

  4. [Fracture of the lunate--a rare injury].

    PubMed

    Höcker, K; Renner, J

    1995-09-01

    Fractures of the normal lunate--isolated or associated with fractures of the scaphoid or radius--are very rare. In the Traumatological Hospital Meidling/Vienna, 12 patients with acute fractures of the lunate bone were treated between 1983 and 1993. Dependent on the fracture-line and the intraosseous vascularity, partial or total avascular necrosis of the bone occurs in rare cases. In dislocated pole fractures, surgical intervention is indicated.

  5. Geometry of proximal femur in the prediction of femoral neck fracture in the elderly female Thai population.

    PubMed

    Lektrakul, Nittaya; Ratarasarn, Onravee

    2009-09-01

    A retrospective study of two groups of 157 patients with one-sided hip fracture and 157 aged matched control group was performed in Siriraj hospital. Geometric measurement of femoral neck was performed as hip axis length (HAL), femoral neck length (FNL), femoral neck width (FNW), femoral head diameter (FHD), acetabular bone width (ABW), and femoral neck-shaft angle (NSA). All geographic parameters are higher in length/width or degree in the femoral neck fracture group than in the normal control group. Among these parameters, ABW has the strongest association with femoral neck fracture (p 0.000, odds ratio = 2.85), followed by FNW (p 0.001, odds ratio = 2.51). According to the low sensitivity and specificity, and ROC curve, using this parameter as a screening tool for femoral neck fracture is still questionable. Further prospective study with a standard position, interval changing of femoral geometry, or combined with bone density or femoral architecture is suggested.

  6. Influence of the upper femur and pelvic geometry on the risk and type of hip fractures.

    PubMed

    Partanen, J; Jämsä, T; Jalovaara, P

    2001-08-01

    The geometry of the upper femur has been reported to associate with the hip fracture risk in postmenopausal women. However, these associations seem to be partly conflicting, probably because of differences in measurement setup. Here, we compared the upper femur and pelvic geometries of 70 hip fracture patients (46 cervical and 24 trochanteric fractures) and 40 age-adjusted controls based on plain anteroposterior radiographs, eliminating the possible sources of inaccuracy as far as possible by using a standardized patient position and calibrated dimension measurements by digital image analysis. The femoral neck/shaft angle (NSA) was larger in the fracture patients compared with the controls (p < 0.001). The fracture group had thinner cortices in the upper femur than the controls (p < 0.001). The femoral shaft diameter (FSD; p < 0.001), trochanter width (TW; p < 0.01), and the pelvic dimensions, that is, the smallest outer pelvic diameter (SOPD; p < 0.01) and the largest inner pelvic diameter (LIPD; p < 0.05) were smaller in the fracture group. Comparing the fracture types, we found NSA larger in the cervical hip fracture patients than in the patients with a trochanteric fracture (p < 0.01). The femoral neck/shaft cortex ratio was lower and the FSD was smaller in the cervical hip fracture group (p < 0.05). Acetabular width (AW) was greater and the SOPD was wider in the cervical fracture patients (p < 0.01). We concluded that the upper femur and pelvic dimensions as defined from calibrated and position-standardized plain radiographs are useful in the evaluation of hip fracture risk and fracture type.

  7. Fracture Management

    MedlinePlus

    ... to hold the fracture in the correct position. • Fiberglass casting is lighter and stronger and the exterior ... with your physician if this occurs. • When a fiberglass cast is used in conjunction with a GORE- ...

  8. Hip Fracture

    MedlinePlus

    ... make older people more likely to trip and fall — one of the most common causes of hip ... Taking steps to maintain bone density and avoid falls can help prevent hip fracture. Signs and symptoms ...

  9. Lisfranc fractures.

    PubMed

    Wright, Amanda; Gerhart, Ann E

    2009-01-01

    Injuries of the tarsometatarsal, or Lisfranc, joint are rarely seen. Lisfranc fractures and fracture dislocations are among the most frequently misdiagnosed foot injuries in the emergency department. A misdiagnosed injury may have severe consequences including chronic pain and loss of foot biomechanics. Evaluation of a foot injury should include a high level of suspicion of a Lisfranc injury, and a thorough work-up is needed for correct diagnosis.

  10. Colles' fracture.

    PubMed

    Altizer, Linda L

    2008-01-01

    Many people "slip and fall", especially in the icy areas of the winter season. To prevent an injury to the head, most people put their hand out to hit the ground first, so the wrist usually gets injured. The most frequent injury from this type of "intervention" is a fracture to the distal radius and/or ulna, which is frequently called a "Colles' fracture."

  11. Boxer's fracture.

    PubMed

    Altizer, Linda

    2006-01-01

    Boxer's fracture is a common name for a fracture of the distal fifth metacarpal and received its name from one of its most common causes, punching an object with a closed fist. It can occur from a fistfight or from punching a hard object. The injury of a "Boxer's Fracture" earned the name from the way in which the injury occurred, punching an immovable object with a closed fist and no boxing mitt (Figure 1). Naturally, a "Boxer" usually punches his fist into his opponent's face or body. An angry person may perform the same action into a person, or into the wall. The third person may be performing a task and strike something with his fist with forceful action accidentally. In any event, if the closed fist "punches" into an immovable or firm object with force, the most frequent injury sustained would be a fracture of the fifth metacarpal neck. Some caregivers would also call a fourth metacarpal neck fracture a boxer's fracture.

  12. [Fractures of the distal radius].

    PubMed

    Rueger, J M; Hartel, M J; Ruecker, A H; Hoffmann, M

    2014-11-01

    The most prevalent fractures managed by trauma surgeons are those involving the distal radius. The injury occurs in two peaks of prevalence: the first peak around the age of 10 years and the second peak around the age of 60 years. Distal radius fracture management requires sensitive diagnostics and classification. The objectives of treatment are the reconstruction of a pain-free unlimited durable functioning of the wrist and avoidance of typical fracture complications. Non-operative conservative management is generally employed for stable non-displaced fractures of the distal radius with the expectation of a good functional outcome. Unstable comminuted fractures with intra-articular and extra-articular fragment zones are initially set in a closed operation and finally by osteosynthesis. An armament of surgical implants is available for instable fractures requiring fixation. Palmar locked plate osteosynthesis has been established in recent years as the gold standard for operative management of distal radius fractures. Complex Working Group on Osteosynthesis (AO) classification type 3 fractures require extensive preoperative diagnostics to identify and treat typical associated injuries around the wrist.

  13. Gravity-Driven Hydraulic Fractures

    NASA Astrophysics Data System (ADS)

    Germanovich, L. N.; Garagash, D.; Murdoch, L. C.; Robinowitz, M.

    2014-12-01

    This study is motived by a new method for disposing of nuclear waste by injecting it as a dense slurry into a hydraulic fracture that grows downward to great enough depth to permanently isolate the waste. Disposing of nuclear waste using gravity-driven hydraulic fractures is mechanically similar to the upward growth of dikes filled with low density magma. A fundamental question in both applications is how the injected fluid controls the propagation dynamics and fracture geometry (depth and breadth) in three dimensions. Analog experiments in gelatin [e.g., Heimpel and Olson, 1994; Taisne and Tait, 2009] show that fracture breadth (the short horizontal dimension) remains nearly stationary when the process in the fracture "head" (where breadth is controlled) is dominated by solid toughness, whereas viscous fluid dissipation is dominant in the fracture tail. We model propagation of the resulting gravity-driven (buoyant or sinking), finger-like fracture of stationary breadth with slowly varying opening along the crack length. The elastic response to fluid loading in a horizontal cross-section is local and can be treated similar to the classical Perkins-Kern-Nordgren (PKN) model of hydraulic fracturing. The propagation condition for a finger-like crack is based on balancing the global energy release rate due to a unit crack extension with the rock fracture toughness. It allows us to relate the net fluid pressure at the tip to the fracture breadth and rock toughness. Unlike the PKN fracture, where breadth is known a priori, the final breadth of a finger-like fracture is a result of processes in the fracture head. Because the head is much more open than the tail, viscous pressure drop in the head can be neglected leading to a 3D analog of Weertman's hydrostatic pulse. This requires relaxing the local elasticity assumption of the PKN model in the fracture head. As a result, we resolve the breadth, and then match the viscosity-dominated tail with the 3-D, toughness

  14. Interfacial fracture toughness of synthetic bone-cement interface

    PubMed Central

    Tong, J

    2008-01-01

    Conventionally, the bonding strength of bone-cement interface is obtained by mechanical strength testing which tends to produce large variability between specimens and test methods. In this work, interfacial fracture toughness of synthetic bone-cement interface has been determined using sandwiched Brazilian disk specimens. Experiments were carried out under selected loading angles from 0 to 25 degrees to achieve full loading conditions from mode I to mode II. Solutions for complex stress intensity factors as well as strain energy release rates were obtained for a sandwich disk with a finite interlayer using the finite element method. Phase angles were obtained at a fixed distance to the crack tip. The fracture loads were obtained from the load displacement curves and the values of interfacial fracture toughness were calculated from the fracture loads and the finite element J-integral solutions. The implication of this information on the assessment of fixation in acetabular replacements was discussed in the light of in-vitro fatigue testing of implanted acetabula. PMID:19325935

  15. Interfacial fracture toughness of synthetic bone-cement interface.

    PubMed

    Tong, J

    2006-06-15

    Conventionally, the bonding strength of bone-cement interface is obtained by mechanical strength testing which tends to produce large variability between specimens and test methods. In this work, interfacial fracture toughness of synthetic bone-cement interface has been determined using sandwiched Brazilian disk specimens. Experiments were carried out under selected loading angles from 0 to 25 degrees to achieve full loading conditions from mode I to mode II. Solutions for complex stress intensity factors as well as strain energy release rates were obtained for a sandwich disk with a finite interlayer using the finite element method. Phase angles were obtained at a fixed distance to the crack tip. The fracture loads were obtained from the load displacement curves and the values of interfacial fracture toughness were calculated from the fracture loads and the finite element J-integral solutions. The implication of this information on the assessment of fixation in acetabular replacements was discussed in the light of in-vitro fatigue testing of implanted acetabula.

  16. The acetabular labrum: anatomic and functional characteristics and rationale for surgical intervention.

    PubMed

    Safran, Marc R

    2010-06-01

    The past decade has seen unprecedented growth in the number of hip arthroscopies. Acetabular labral tears are the leading indication for arthroscopy of this joint. However, labral anatomy and function, as well as the effects of labral tears and surgical outcomes, have only recently been studied. Labral tears may cause pain and microinstability of the hip joint. They also may increase friction within the joint, cartilage consolidation, and strain within the articular cartilage, thereby possibly resulting in accelerated degeneration of the joint. Partial labrectomy and labral repair are the current surgical options, and basic science data suggest that labral repairs can heal and subsequently restore function. However, a good, validated outcomes measure to adequately assess active patients with a painful nonarthritic hip is needed to determine the efficacy of such repair and aid in managing patient expectations.

  17. Fractures of Distal Radius: An Overview

    PubMed Central

    Meena, Sanjay; Sharma, Pankaj; Sambharia, Abhishek Kumar; Dawar, Ashok

    2014-01-01

    Fractures of distal radius account for up to 20% of all fractures treated in emergency department. Initial assessment includes a history of mechanism of injury, associated injury and appropriate radiological evaluation. Treatment options include conservative management, internal fixation with pins, bridging and non-bridging external fixation, dorsal or volar plating with/without arthroscopy assistance. However, many questions regarding these fractures remain unanswered and good prospective randomized trials are needed. PMID:25657938

  18. Posterior dislocation of hip with ipsilateral intertrochanteric fracture: A report of two cases

    PubMed Central

    Ul Haq, Rehan; Kumar, Jaswant; Dhammi, IK; Jain, Anil K

    2016-01-01

    Posterior dislocations of the hip are known to be associated with fractures of the femoral head, neck, shaft, or posterior acetabular wall. However, its association with ipsilateral intertrochanteric fracture has only been anecdotally described in the English literature. We report two such cases managed by open reduction (OR) of the hip and internal fixation (IF) of the intertrochanteric fracture. The first case was a 26-year-old male who was managed by OR of the hip with IF of the intertrochanteric fracture with a dynamic hip screw and had a good functional result at 1-year followup. The second case was a 36-year-old female who was also managed by OR of the hip with IF of the head fragments with Herbert screw and IF of the intertrochanteric fracture with a dynamic condylar screw. The patient had a fair, functional result at 1-year followup. With the increase in high energy trauma, these fracture patterns have become more common, and there is an urgent need to review the existing classifications so that these fractures are better categorized, and treatment guidelines defined. PMID:27746503

  19. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.

    PubMed

    McKellop, H; Shen, F W; DiMaio, W; Lancaster, J G

    1999-12-01

    Crosslinking of ultrahigh molecular weight polyethylene has been shown to markedly improve its wear resistance in clinical studies and laboratory tests using hip joint simulators. However, because most of the laboratory studies have been done under clean conditions using prosthesis-quality, highly polished counterfaces, there is concern regarding how well an intentionally crosslinked polyethylene acetabular cup will resist abrasion by a femoral ball that has been damaged by third-body abrasion in vivo. To investigate this, conventional and radiation crosslinked-remelted acetabular cups of ultra-high molecular weight polyethylene were tested in a hip joint simulator bearing against smooth femoral balls and against balls with moderate and severe roughening. Cups were tested with and without aging to accelerate any oxidative degradation. The crosslinked cups were produced by exposing extruded GUR 4150 bar stock of ultrahigh molecular weight polyethylene to 5 Mrad gamma radiation under a partial vacuum and then the bars were remelted to extinguish residual free radicals. Artificial aging at 70 degrees C under 5 atm oxygen for 14 days induced negligible oxidation in the crosslinked and remelted material. Against smooth balls, the wear of the crosslinked cups, with or without aging, averaged approximately 15% of that of the conventional cups. Against the moderately rough balls, the wear rate of the conventional cups was unchanged, whereas the wear rate increased slightly for the nonaged and aged crosslinked cups, but was still only 26% and 20% of that of the conventional cups, respectively. Against extremely rough balls, the mean wear rates increased markedly for each material such that during the final 1 million cycle interval, the average wear rates of the nonaged and the aged crosslinked cups were 72% and 47% of that of the conventional cups, respectively. That is, the crosslinked polyethylene showed substantially better wear resistance than conventional polyethylene

  20. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    PubMed Central

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-01-01

    Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150

  1. Fracture types (1) (image)

    MedlinePlus

    ... fracture which goes at an angle to the axis Comminuted - a fracture of many relatively small fragments Spiral - a fracture which runs around the axis of the bone Compound - a fracture (also called ...

  2. Hydraulic fracturing-1

    SciTech Connect

    Not Available

    1990-01-01

    This book contains papers on hydraulic fracturing. Topics covered include: An overview of recent advances in hydraulic fracturing technology; Containment of massive hydraulic fracture; and Fracturing with a high-strength proppant.

  3. Healing of patellar fractures in two kittens.

    PubMed

    Hermer, J V; Bush, M A; Whiting, C; Langley-Hobbs, S J

    2012-01-01

    Two kittens aged between four and five months were presented having sustained patellar fractures. In both cases, healing was subsequently documented radiographically; this has not been reported previously in the literature. One kitten had bilateral patellar fractures - the symptomatic right stifle was treated with a pin and tension-band-wire which later failed, at which point partial patellectomy was performed. The fracture of the left patella was minimally displaced and was treated conservatively. A radiograph of the left patella taken eleven months after initial presentation showed complete healing of the fracture. The second case was treated surgically with a circumferential wire; healing of the fracture was demonstrated radiographically at twelve weeks postoperatively. Radiographic images taken five weeks postoperatively had shown some narrowing of the fracture gap. These two cases demonstrate that bony union of patellar fractures can be documented, given a long enough duration of radiographic follow-up; circumferential wire was an effective treatment in a displaced fracture, and conservative treatment resulted in complete healing of a minimally displaced fracture.

  4. Restoration of a fractured primary incisor.

    PubMed

    Romero, M; Saez, M; Cabrerizo, C

    2001-01-01

    Esthetic restoration on primary teeth has been a special challenge to pediatric dentists. Composite restorations are the most often used treatment for decay and fractures of primary teeth, however, there are other possible alternatives. We present a case in which we have used an acrylic crown to treat a fractured primary incisor in a 1.8 years old child.

  5. Condylar fractures.

    PubMed

    Sawhney, Raja; Brown, Ryan; Ducic, Yadranko

    2013-10-01

    The purpose of this article is to review the basic indications for different treatments of condylar and subcondylar fractures. It also reviews the steps of different surgical approaches to access the surgical area and explains the pros and cons of each procedure.

  6. Acetabular revision with impaction bone grafting and a cemented polyethylene acetabular component: comparison of the Kaplan-Meier analysis to the competing risk analysis in 62 revisions with 25 to 30 years follow-up.

    PubMed

    Te Stroet, M A J; Keurentjes, J C; Rijnen, W H C; Gardeniers, J W M; Verdonschot, N; Slooff, T J J H; Schreurs, B W

    2015-10-01

    We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). We performed Kaplan-Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint 're-revision for any reason' was 58.0% (95% confidence interval (CI) 38 to 73) and for 're-revision for aseptic loosening' 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years.

  7. [Estimation of absolute risk for fracture].

    PubMed

    Fujiwara, Saeko

    2009-03-01

    Osteoporosis treatment aims to prevent fractures and maintain the QOL of the elderly. However, persons at high risk of future fracture cannot be effectively identified on the basis of bone density (BMD) alone, although BMD is used as an diagnostic criterion. Therefore, the WHO recommended that absolute risk for fracture (10-year probability of fracture) for each individual be evaluated and used as an index for intervention threshold. The 10-year probability of fracture is calculated based on age, sex, BMD at the femoral neck (body mass index if BMD is not available), history of previous fractures, parental hip fracture history, smoking, steroid use, rheumatoid arthritis, secondary osteoporosis and alcohol consumption. The WHO has just announced the development of a calculation tool (FRAX: WHO Fracture Risk Assessment Tool) in February this year. Fractures could be prevented more effectively if, based on each country's medical circumstances, an absolute risk value for fracture to determine when to start medical treatment is established and persons at high risk of fracture are identified and treated accordingly.

  8. Al-Cu-Fe quasicrystal/ultra-high molecular weight polyethylene composites as biomaterials for acetabular cup prosthetics.

    PubMed

    Anderson, Brian C; Bloom, Paul D; Baikerikar, K G; Sheares, Valerie V; Mallapragada, Surya K

    2002-04-01

    Polymer composites of Al-Cu-Fe quasicrystals and ultra-high molecular weight polyethylene (UHMWPE) were investigated for use in acetabular cup prosthetics. The wear properties of the Al-Cu-Fe/UHMWPE samples and a 440 steel ball counterface were measured. The mechanical strength of the Al-Cu-Fe/UHMWPE composites was compared to UHMWPE and alumina/UHMWPE. The biocompatibility of the composite material was tested using a direct contact cytotoxicity assay. Al-Cu-Fe/UHMWPE demonstrated lower volume loss after wear and higher mechanical strength than UHMWPE. This composite material also showed no increase in counterface wear or cytotoxicity relative to UHMWPE. These combined results demonstrate that Al-Cu-Fe/UHMWPE composites are promising candidate materials for acetabular cup prosthetics.

  9. Effects of screw eccentricity on the initial stability of the acetabular cup in artificial foam bone of different qualities.

    PubMed

    Hsu, Jui-Ting; Lin, Dan-Jae

    2010-01-01

    Acetabular cup loosening is one of the major failure models of total hip replacement (THR), which is mostly due to insufficient initial stability of the cup. Previous studies have demonstrated that cup stability is affected by the quality of the host bone and the surgical skill when inserting screws. The purpose of this study was to determine the effects on the initial stability of the acetabular cup of eccentric screws in bone of different qualities. In this study, hemispherical cups were fixed into bone specimens constructed from artificial foam with three elastic moduli using one to three screws. The effects of two types of screw eccentricity (offset and angular) on the stability of the acetabular cup were also evaluated. The experimental results indicate that in the presence of ideal screwing, the cup was stable in bone specimens constructed from foam with the highest elastic modulus. In addition, increasing the number of ideal screws enhanced the cup stability, especially in bone specimens constructed from soft foam. Moreover, the cup stability was most affected by offset eccentric screw(s) in the hard-foam bone specimens and by angular eccentric screw(s) in the soft-foam bone specimens. The reported results indicate that the presence of screw eccentricity affects the initial stability of the acetabular cup. Surgeons should keep this in mind when performing screw insertions in THR. However, care is necessary when translating these results to the intraoperative situation due to the experiments being conducted under laboratory conditions, and hence, future studies should attempt to replicate the results reported here in vivo.

  10. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    PubMed

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  11. Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim

    PubMed Central

    Bonneau, Noémie; Bouhallier, July; Baylac, Michel; Tardieu, Christine; Gagey, Olivier

    2012-01-01

    Understanding the three-dimensional orientation of the coxo-femoral joint remains a challenge as an accurate three-dimensional orientation ensure an efficient bipedal gait and posture. The quantification of the orientation of the acetabulum can be performed using the three-dimensional axis perpendicular to the plane that passes along the edge of the acetabular rim. However, the acetabular rim is not regular as an important indentation in the anterior rim was observed. An innovative cadaver study of the labrum was developed to shed light on the proper quantification of the three-dimensional orientation of the acetabulum. Dissections on 17 non-embalmed corpses were performed. Our results suggest that the acetabular rim is better represented by an anterior plane and a posterior plane rather than a single plane along the entire rim as it is currently assumed. The development of the socket from the Y-shaped cartilage was suggested to explain the different orientations in these anterior and posterior planes. The labrum forms a plane that takes an orientation in between the anterior and posterior parts of the acetabular rim, filling up inequalities of the bony rim. The vectors VL, VA2 and VP, representing the three-dimensional orientation of the labrum, the anterior rim and the posterior rim, are situated in a unique plane that appears biomechanically dependent. The three-dimensional orientation of the acetabulum is a fundamental parameter to understand the hip joint mechanism. Important applications for hip surgery and rehabilitation, as well as for physical anthropology, were discussed. PMID:22360458

  12. Finite element analysis of the stability of combined plate internal fixation in posterior wall fractures of acetabulum

    PubMed Central

    Liu, Xi-Ming; Pan, Chang-Wu; Wang, Guo-Dong; Cai, Xian-Hua; Chen, Lei; Meng, Cheng-Fei; Huang, Jin-Cheng

    2015-01-01

    Objective: This study aims to explore the mechanical stability of combined plate internal fixation in posterior wall fractures of the acetabulum. Methods: The fracture and internal fixation models were established in this study and they were divided into four kinds of internal fixation models, finite element analysis was performed. The four groups were 2 mini-plates and 1 reconstruction plate fixation (A), Reconstruction plate internal fixation group (B), 2 screws internal fixation group (C) and mini-plates internal fixation group (D). The displacement of each node was measured and evaluated. Results: There was no distortion in the geometric shape of the finite element model. The results of stress showed that it was less in the anterior pelvic ring and distributed uniform in labrum acetabulare; the stress was bigger in the upper and middle of sacroiliac joint and sciatic notch in sitting position. Conclusions: Combined plate internal fixation for posterior wall fractures of acetabular were stable and reliable, it is better than the other three methods. PMID:26550272

  13. Temporal and spatial distributions of directional counterface motion at the acetabular bearing surface in total hip arthroplasty.

    PubMed Central

    Pedersen, D. R.; Brown, T. D.; Maxian, T. A.; Callaghan, J. J.

    1998-01-01

    The motions of counterface articulation against the bearing surface of the acetabular liner strongly influence polyethylene wear debris production in contemporary total hip arthroplasty. However, the available body of relevant articular force and motion information is largely confined to resultant load excursions measured relative to instrumented femoral components, and/or to global angular motions (flexion, adduction, endorotation) of the joint. Analytical frameworks are here developed to transform such information into temporal and spatial variations of the resultant load and of the local counterface sliding velocity relative to an ordered set of discrete locations (e.g., finite element nodes) on the acetabular bearing surface. Whole-duty-cycle time histories of acetabular resultant load and counterface velocity distributions are presented for two important practical situations: human level walking gait, and a 23 degrees biaxial rocking hip simulation machine. The local counterface motions occurring in the simulator are characterized by higher velocities, smoother motion patterns, and wider directional variation than those occurring in human gait. PMID:9807707

  14. Pathologic femoral neck fractures in children.

    PubMed

    Shrader, M Wade; Schwab, Joseph H; Shaughnessy, William J; Jacofsky, David J

    2009-02-01

    Pathologic fractures in children occur in a variety of malignant and benign pathologic processes. Pediatric pathologic femoral neck fractures are particularly rare. Until now, all reported cases have been isolated cases, small series, or cases reported in series of adult pathologic hip fractures. The present article is the first report of a relatively large series of pathologic femoral neck fractures in a pediatric population. We identified pathologic femoral neck fractures, including 2 basicervical fractures, in 15 children (9 boys, 6 girls) ranging in age from 18 months to 15 years (mean age, 9 years) and treated between 1960 and 2000. The pathologic diagnoses were fibrous dysplasia (5 children), unicameral bone cyst (2), Ewing's sarcoma (2), osteomyelitis (2), leukemia (1), rhabdomyosarcoma (1), osteogenesis imperfecta (1), and osteopetrosis (1). Treatment methods, including time to reduction and fixation, were reviewed in detail. One patient was lost to follow-up. All others were followed until union; mean long-term follow-up was 7 years (range, 1-16 years). All patients ultimately went on to union. Mean time to union was 19 weeks (range, 5-46 weeks). However, 2 patients died before 2 years. There was a 40% complication rate, with limb-length discrepancy being the most common (4 children). No patient developed avascular necrosis. Pathologic femoral neck fractures are rare in children. Pediatric patients who present with a pathologic hip fracture are at significant risk for complications. Physicians and family should be alerted to the prolonged course involved in treating these fractures to union.

  15. Facial Fractures

    PubMed Central

    White, Lawrence M.; Marotta, Thomas R.; McLennan, Michael K.; Kassel, Edward E.

    1992-01-01

    Appropriate clinical radiographic investigation, together with an understanding of the normal radiographic anatomy of the facial skeleton, allows for precise delineation of facial fracutres and associated soft tissue injuries encountered in clinical practice. A combination of multiple plain radiographic views and coronal and axial computed tomographic images allow for optimal delineation of fracture patterns. This information is beneficial in the clinical and surgical management patients with facial injuries

  16. Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

    PubMed Central

    Hamada, Daisuke; Iwame, Toshiyuki; Sairyo, Koichi

    2016-01-01

    The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a metal femoral head provides satisfactory results. We report an unusual case of progressive osteolysis due to metallosis that developed after revision THA for ceramic liner dissociation without a liner fracture performed using a metal femoral head and polyethylene liner. The residual metal debris and abnormal pumping motion of the polyethylene liner due to the breakage of the locking system or the aspherical metal shell being abraded by the ceramic head seemed to be the cause of the progressive osteolysis. PMID:27648325

  17. Anterior fracture displacement in Colles' fractures after Kapandji wiring in women over 59 years.

    PubMed

    Hollevoet, Nadine; Verdonk, René

    2007-06-01

    The aim of this study was to assess the radiological results of Colles' fractures treated with Kapandji wiring and to determine the frequency of postoperative anterior fracture displacement. The X-rays of 89 fractures in women over 59 years of age were evaluated. Five weeks after injury, palmar shift of the distal fracture fragments and/or palmar tilt of more than 20 degrees were observed in 26 patients. In ten wrists dorsal tilt was not sufficiently corrected and measured more than 10 degrees . Increase in ulnar variance was more than 2 mm in 37 wrists and more than 5 mm in six wrists; this was more pronounced when the palmar tilt was not corrected properly or when anterior fracture displacement was present. We conclude that Kapandji wiring may not be able to prevent anterior fracture displacement in almost one-third of Colles' fractures in osteoporotic elderly patients.

  18. [Triple fracture of the shoulder suspensory complex].

    PubMed

    Tamimi Mariño, I; Martin Rodríguez, I; Mora Villadeamigo, J

    2013-01-01

    The superior suspensory complex of the shoulder (SSCS) is a ring shaped structure composed of bones and soft tissues that play a fundamental role in the stability of the shoulder joint. Isolated injuries of the SSCS are relatively common, but injuries that affect 3 components are extremely unusual. We present a triple injury of the SSCS in a 26 year old patient with a Neer type ii clavicular fracture, a Kuhn type iii acromion fracture and an Ogawa type i coracoid fracture. An open reduction and stabilization of the clavicle was performed with 2 Kirschner nails. The acromial fracture was synthesized with 2 cannulated screws, and the coracoid fracture was treated conservatively. After 24 months of follow up the patient had an excellent functional outcome according to the Constat-Murley shoulder score and QuickDASH scoring system, and all the fractures healed correctly.

  19. Evaluation and Management of Proximal Humerus Fractures

    PubMed Central

    Khmelnitskaya, Ekaterina; Lamont, Lauren E.; Taylor, Samuel A.; Lorich, Dean G.; Dines, David M.; Dines, Joshua S.

    2012-01-01

    Proximal humerus fractures are common injuries, especially among older osteoporotic women. Restoration of function requires a thorough understanding of the neurovascular, musculotendinous, and bony anatomy. This paper addresses the relevant anatomy and highlights various management options, including indication for arthroplasty. In the vast majority of cases, proximal humerus fractures may be treated nonoperatively. In the case of displaced fractures, when surgical intervention may be pursued, numerous constructs have been investigated. Of these, the proximal humerus locking plate is the most widely used. Arthroplasty is generally reserved for comminuted 4-part fractures, head-split fractures, or fractures with significant underlying arthritic changes. Reverse total shoulder arthroplasty is reserved for patients with a deficient rotator cuff, or highly comminuted tuberosities. PMID:23316376

  20. Management of Complications of Distal Radius Fractures

    PubMed Central

    Chung, Kevin C.; Mathews, Alexandra L.

    2015-01-01

    Synopsis Treating a fracture of the distal radius may require the surgeon to make a difficult decision between surgical treatment and nonsurgical management. The use of surgical fixation has recently increased owing to complications associated with conservative treatment. However, conservative action may be necessary depending on certain patient factors. The treating surgeon must be aware of the possible complications associated with distal radius fracture treatments to prevent their occurrence. Prevention can be achieved with a proper understanding of the mechanism of these complications. This article discusses the most recent evidence on how to manage and prevent complications following a fracture of the distal radius. PMID:25934197

  1. Facial Fracture Management in Northwest Nigeria

    PubMed Central

    Taiwo, Abdurrazaq Olanrewaju; Soyele, Olujide Oladele; Godwin, Ndubuizi Ugochukwu; Ibikunle, Adebayo Aremu

    2013-01-01

    Background: Facial fracture is gradually become a public health problem in our community due to the attendant morbidity and mortality. Hence, the aim of this study was to determine the pattern of facial fracture in Dental and Maxillofacial Surgery Department of Usmanu Danfodiyo University Teaching Hospital. This cross-sectional study was undertaken to provide information regarding gender, age, etiology, and diagnosis of patients with maxillofacial fractures. Materials and Methods: A 1-year review of patients diagnosed and treated for facial fractures in Usmanu Danfodiyo University Teaching Hospital between January 2011 and December 2011. The diagnosis was based on radiographic data and clinical examination. The main analysis outcome measures were etiology, age, gender, site, and treatment. Data were organized and presented by means of descriptive statistics and Pearson's Chi-square test. The level of significance adopted was 5%. Results: A total of 40 patients were treated in this period. Over 95% were male, 81% were caused by road traffic crash (RTC) and 86.4% were in the 21-30 years group. Most patients (52%) had mandibular fractures, and the most common site was the body. Most patients with midfacial fractures had fractures of the zygomaticomaxillary region (36%), while fractures of the parasymphyseal region were more common in the mandible 156 (31%). The most common treatment for jaw fractures was mandibulomaxillary fixation (MMF). Stable zygomatic complex fractures were reduced (elevated) intraorally, and unstable ones were supported by antral packs. Conclusions: This study highlights facial fractures secondary to RTC as a serious public health problem in our environment. Preventive strategies remain the cheapest way to reduce direct and indirect costs of the sequelae of RTC. It also bring to the fore the necessity to shift to open reduction and internal fixation (ORIF) of fractures. PMID:24741422

  2. Fractures of the mandibular coronoid process: a two centres study.

    PubMed

    Boffano, Paolo; Kommers, Sofie C; Roccia, Fabio; Gallesio, Cesare; Forouzanfar, Tymour

    2014-10-01

    The aim of this study was to assess the characteristics of patients with coronoid fractures treated in two European centres over 10 years and to briefly review the literature. This study is based on 2 systematic computer-assisted databases that have continuously recorded patients hospitalized with maxillofacial fractures and surgically treated in two European centres between 2001 and 2010. During the 10 years, 1818 patients and 523 patients with maxillofacial fractures were admitted to the two centres respectively: 21 patients (16 males, 5 females) were admitted with 21 coronoid fractures and 28 associated maxillofacial fractures. A mean age of 42.1 years was observed. The fractures were mainly the result of motor vehicle accidents, followed by assaults and falls. The most frequently observed associated maxillofacial fracture was a zygomatic fracture (13 fractures). In both centres, mandibular coronoid fractures are treated unless a severe dislocation of the fractured coronoid is observed or a functional mandibular impairment is encountered. Conservative treatment can be used, together with the open reduction and internal fixation of associated fractures. The crucial point is to prevent ankylosis, which may be prevented by correct and early postoperative physiotherapy and mandibular function.

  3. Dilemmas in imaging for peri-acetabular osteotomy: the influence of patient position and imaging technique on the radiological features of hip dysplasia.

    PubMed

    Kosuge, D; Cordier, T; Solomon, L B; Howie, D W

    2014-09-01

    Peri-acetabular osteotomy is an established surgical treatment for symptomatic acetabular dysplasia in young adults. An anteroposterior radiograph of the pelvis is commonly used to assess the extent of dysplasia as well as to assess post-operative correction. Radiological prognostic factors include the lateral centre-edge angle, acetabular index, extrusion index and the acetabular version. Standing causes a change in the pelvis tilt which can alter certain radiological measurements relative to the supine position. This article discusses the radiological indices used to assess dysplasia and reviews the effects of patient positioning on these indices with a focus on assessment for a peri-acetabular osteotomy. Intra-operatively, fluoroscopy is commonly used and the implications of using fluoroscopy as a modality to assess the various radiological indices along with the effects of using an anteroposterior or posteroanterior fluoroscopic view are examined. Each of these techniques gives rise to a slightly different image of the pelvis as the final image is sensitive to the position of the pelvis and the projection of the x-ray beam.

  4. Simultaneous fracture of the waist of the scaphoid and the hook of the hamate.

    PubMed

    Komura, Shingo; Suzuki, Yasushi; Ikehata, Tatsuya

    2010-01-01

    A case of simultaneous fracture of the waist of the scaphoid and the hook of the hamate is presented. The scaphoid fracture was treated surgically with a headless compression screw, while the hook fracture was treated conservatively with cast immobilisation for eight weeks. Both fractures achieved bone union and the patient returned to work without any symptoms or complications. Only two cases of fractures of the scaphoid and hamate have been reported previously. However, both of them involved fracture of the body of the hamate. This is the first report of simultaneous fracture of the scaphoid and the hook of the hamate.

  5. Two-incision technique for rotational acetabular osteotomy: good outcome in 35 hips.

    PubMed

    Pajarinen, Jarkko; Hirvensalo, Eero

    2003-04-01

    We have developed a 2-incision technique for rotational acetabular osteotomy. This includes both an extraperitoneal and an anterolateral exposure of the pelvic bones allowing an unconstrained approach without dissection of the muscle insertion. 2 plates are used to stabilize the osteotomy and full range motion of the hip is permitted within 2 days of surgery, while weight bearing is restricted for 6 weeks after the operation. We reviewed the complications and technical results in 27 patients (28 hips) after a minimum follow-up of mean 3 (1-5) years. No major surgical complications occurred, but dysfunction of the lateral femoral cutaneous nerve occurred frequently (14 patients). The radiographical correction of the femoral head covering was similar to those in previous reports of rotational osteotomy. The range of hip motion was not affected by the operation. A significant increase in the mean Merle D'Aubigné and Harris Hip scores was observed in a subgroup of 20 patients with a minimum follow-up of 2 years. In conclusion, the method we have used is safe and the early results are satisfactory.

  6. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    PubMed Central

    Nakashima, Yasuharu; Nakamura, Tetsuro; Ito, Yoshihiro; Hara, Toshihiko

    2017-01-01

    Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups) in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months). The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE) angle and the bone coverage index (BCI) from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3%) and the minimum cup-CE angle was −9.2° (BCI: 48.8%). Thin radiolucent lines were observed in 5 hips (2.3%), which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50%) was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%). PMID:28299327

  7. Ultra high molecular weight polyethylene and polydimethylsiloxane blend as acetabular cup material.

    PubMed

    Khorasani, M T; Zaghiyan, M; Mirzadeh, H

    2005-03-25

    An acetabular cup shock absorber implant is formed from a composite of polymer materials. The cup consists of three zones such as the articulating surface of the implant is 100% ultra high molecular weight polyethylene (UHMWPE) (zone 1) and shock absorber of the cup contains of polydimethylsiloxane (PDMS) (zone 3). Zone 2 which is designed for better adhesion between zone 1 and zone 2 consists of a blend of UHMWPE and PDMS is a cushion that from one side adheres to zone 1 and the other side to zone 2. PDMS and UHMWPE have been blended under conditions of shear and elevated temperature in order to form uniform, thermoplastic blends. When blends compared to pure UHMWPE, the blends show lowered tensile modulus and lowered mixing energies. The UHMWPE crystals are increased in quantity or else become more regular, even 50% blend shows no rubbery stage. The morphology and dynamic mechanical behavior of the blends were studied using scanning electron microscopy (SEM) and dynamic mechanic thermal analysis (DMTA). In this study, the biocompatibility have evaluated in vitro the interaction of UHMWPE, silicone and PDMS/UHMWPE blends with L929 fibroblast cells.

  8. The capsular ligaments provide more hip rotational restraint than the acetabular labrum and the ligamentum teres

    PubMed Central

    van Arkel, R. J.; Amis, A. A.; Cobb, J. P.; Jeffers, J. R. T.

    2015-01-01

    In this in vitro study of the hip joint we examined which soft tissues act as primary and secondary passive rotational restraints when the hip joint is functionally loaded. A total of nine cadaveric left hips were mounted in a testing rig that allowed the application of forces, torques and rotations in all six degrees of freedom. The hip was rotated throughout a complete range of movement (ROM) and the contributions of the iliofemoral (medial and lateral arms), pubofemoral and ischiofemoral ligaments and the ligamentum teres to rotational restraint was determined by resecting a ligament and measuring the reduced torque required to achieve the same angular position as before resection. The contribution from the acetabular labrum was also measured. Each of the capsular ligaments acted as the primary hip rotation restraint somewhere within the complete ROM, and the ligamentum teres acted as a secondary restraint in high flexion, adduction and external rotation. The iliofemoral lateral arm and the ischiofemoral ligaments were primary restraints in two-thirds of the positions tested. Appreciation of the importance of these structures in preventing excessive hip rotation and subsequent impingement/instability may be relevant for surgeons undertaking both hip joint preserving surgery and hip arthroplasty. Cite this article: Bone Joint J 2015; 97-B:484–91. PMID:25820886

  9. Explicit finite element modelling of the impaction of metal press-fit acetabular components.

    PubMed

    Hothi, H S; Busfield, J J C; Shelton, J C

    2011-03-01

    Metal press-fit cups and shells are widely used in hip resurfacing and total hip replacement procedures. These acetabular components are inserted into a reamed acetabula cavity by either impacting their inner polar surface (shells) or outer rim (cups). Two-dimensional explicit dynamics axisymmetric finite element models were developed to simulate these impaction methods. Greater impact velocities were needed to insert the components when the interference fit was increased; a minimum velocity of 2 m/s was required to fully seat a component with a 2 mm interference between the bone and outer diameter. Changing the component material from cobalt-chromium to titanium alloy resulted in a reduction in the number of impacts on the pole to seat it from 14 to nine. Of greatest significance, it was found that locking a rigid cap to the cup or shell rim resulted in up to nine fewer impactions being necessary to seat it than impacting directly on the polar surface or using a cap free from the rim of the component, as is the case with many commercial resurfacing cup impaction devices currently used. This is important to impactor design and could make insertion easier and also reduce acetabula bone damage.

  10. Fracture Mechanics

    DTIC Science & Technology

    1974-01-31

    2219 -T851 aluminum (fractures at low stresses). The parameter KF is alloy compact specimens 1 2 and demonstrate consistent a function of specimen...Congress of 20. Walker, E. K., "The Effect of Stress Ratio Applied Mechanics, 1924. During Crack Propagation and Fatigue for 2024-T3 and 7015- T6 Aluminum ...34Stress- Corrosion Cracking in 12. Kaufman, J. G., and Nelson, F. G., "More Ti-6A1-4V Titanium Alloy in Nitrogen Tetroxide," on Specimen Size Effect in 2219

  11. Water fluoridation and osteoporotic fracture.

    PubMed

    Hillier, S; Inskip, H; Coggon, D; Cooper, C

    1996-09-01

    Osteoporotic fractures constitute a major public health problem. These fractures typically occur at the hip, spine and distal forearm. Their pathogenesis is heterogeneous, with contributions from both bone strength and trauma. Water fluoridation has been widely proposed for its dental health benefits, but concerns have been raised about the balance of skeletal risks and benefits of this measure. Fluoride has potent effects on bone cell function, bone structure and bone strength. These effects are mediated by the incorporation of fluoride ions in bone crystals to form fluoroapatite, and through an increase in osteoblast activity. It is believed that a minimum serum fluoride level of 100 ng/ml must be achieved before osteoblasts will be stimulated. Serum levels associated with drinking water fluoridated to 1 ppm are usually several times lower than this value, but may reach this threshold at concentrations of 4 ppm in the drinking water. Animal studies suggest no effect of low-level (0-3 ppm) fluoride intake on bone strength, but a possible decrease at higher levels. Sodium fluoride has been used to treat established osteoporosis for nearly 30 years. Recent trials of this agent, prescribed at high doses, have suggested that despite a marked increase in bone mineral density, there is no concomitant reduction in vertebral fracture incidence. Furthermore, the increase in bone density at the lumbar spine may be achieved at the expense of bone mineral in the peripheral cortical skeleton. As a consequence, high dose sodium fluoride (80 mg daily) is not currently used to treat osteoporosis. At lower doses, recent trials have suggested a beneficial effect on both bone density and fracture. The majority of epidemiological evidence regarding the effect of fluoridated drinking water on hip fracture incidence is based on ecological comparisons. Although one Finnish study suggested that hip fracture rates in a town with fluoridated water were lower than those in a matching town

  12. The Influence of Pelvic Ramus Fracture on the Stability of Fixed Pelvic Complex Fracture

    PubMed Central

    Lei, Jianyin; Zhang, Yue; Wu, Guiying; Wang, Zhihua; Cai, Xianhua

    2015-01-01

    This study aims to evaluate the biomechanical mechanism of pelvic ring injury for the stability of pelvis using the finite element (FE) method. Complex pelvic fracture (i.e., anterior column with posterior hemitransverse lesion) combined with pelvic ramus fracture was used to evaluate the biomechanics stability of the pelvis. Three FE fracture models (i.e., Dynamic Anterior Plate-Screw System for Quadrilateral Area (DAPSQ) for complex pelvic fracture with intact pubic ramus, DAPSQ for complex pelvic fracture with pubic ramus fracture, and DAPSQ for complex pelvic fracture with fixed pubic ramus fracture) were established to explore the biomechanics stability of the pelvis. The pubic ramus fracture leads to an unsymmetrical situation and an unstable situation of the pelvis. The fixed pubic ramus fracture did well in reducing the stress levels of the pelvic bone and fixation system, as well as displacement difference in the pubic symphysis, and it could change the unstable situation back to a certain extent. The pelvic ring integrity was the prerequisite of the pelvic stability and should be in a stable condition when the complex fracture is treated. PMID:26495033

  13. Radial head fracture - aftercare

    MedlinePlus

    Elbow fracture - radial head - aftercare ... to 2 weeks. If you have a small fracture and your bones did not move around much, ... to see a bone doctor (orthopedic surgeon). Some fractures require surgery to: Insert pins and plates to ...

  14. Hand fracture - aftercare

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000552.htm Hand fracture - aftercare To use the sharing features on ... need to be repaired with surgery. Types of Hand Fractures Your fracture may be in one of ...

  15. Proximal Fifth Metatarsal Fractures: Anatomy, Classification, Treatment and Complications

    PubMed Central

    Cheung, Chi Nok; Lui, Tun Hing

    2016-01-01

    Context Fractures of proximal fifth metatarsal are one of the most common fractures of the foot. Evidence Acquisition A search of PubMed for studies on proximal fifth metatarsal fracture and Jones fracture focusing on the classification and management was performed. The reference list of the retrieved articles was searched for additional related studies. Results The vascular supply and soft tissue anatomy of the fifth metatarsal explains the increased risk of delayed union and non-union in fractures at the metaphyseal-diaphyseal junction. Lawrence and Botte classify proximal fifth metatarsal fractures according to their location: tuberosity avulsion fractures (zone 1), fractures at metaphyseal-diaphyseal junction extending into the fourth-fifth intermetatarsal joint (zone 2) and proximal diaphyseal fractures (zone 3). Zone 1 fractures are treated conservatively with functional immobilization and early mobilization with excellent outcome. For zone 2 and zone 3 fractures, acute forms can be treated conservatively but with a risk of delayed union time and time for return to function. Therefore, early surgical fixation with intramedullary screw is advised in athletic individuals. For cases presented with signs of delayed union and non-union, surgical treatment with or without bone grafting is recommended. Complications of these fractures and their management are discussed in this report. Conclusions Lawrence and Botte’s classification of proximal fifth metatarsal fractures is recommended by experts, due to its implication on prognosis and treatment strategy. Zone 1 fractures should be treated conservatively due to their excellent healing potential. Early operative treatment is advised for zone 2 and zone 3 fractures, especially in the athletic group. Complications of delayed union, non-union and refractures should be treated by revision fixation and bone grafting. PMID:28144601

  16. Chopart fractures.

    PubMed

    Klaue, Kaj

    2004-09-01

    The Chopart articular space was described by François Chopart (1743-1795) as a practical space for amputations in cases of distal foot necrosis. It corresponds to the limit between the anatomical hind-foot and the mid-foot. The bones involved are the talus and the calcaneus proximally, and the navicular and the cuboid distally. This space thus holds two functionally distinct entities, the anterior part of the coxa pedis (an essential functional joint) and the calcaneo-cuboidal joint,which can be considered to be an "adaptive joint" within a normal foot. Trauma to this region may cause fractures and/or dislocations and, in high energy trauma,compartment syndromes. Principles of treatment are immediate reduction of dislocations and realignment of the medial and lateral column of the foot in length and orientation. Open reduction and internal fixation of talus and navicular fractures are often indicated to restore the "coxa pedis". Open reconstruction or fusion in correct length of the calcaneo-cuboidal joint is occasionally indicated. Salvage procedures in malunions include navicular osteotomies and calcaneo-cuboidal bone block fusions. Treatment of joint destructions, especially involving the talo-navicular joint, include triple arthrodesis.

  17. Interlocking Intramedullary Nails in Fracture Treatment.

    PubMed

    Ouyang, Xiao; Wang, Jing Rong; Hong, Shi Dong; Xin, Feng; Wang, Lin; Yang, Xiao Wei; Wang, Jian

    2015-09-01

    The aim of this study is to evaluate interlocking intramedullary nails in the treatment of fractures. We retrospectively reviewed 68 adult patients (for a total of 95 fractures) with isolated long-bone fractures who were treated with interlocking intramedullary nails between January 2010 and January 2012. The patients were followed for 18 months to observe the healing of the fracture, time, and the occurrence of complications in the shoulder, knee, and hip joint functions. After about a follow-up period of 26.2 months (range 18-39 months), all cases obtained bony union. The mean time to fracture union was 5.2 months. Cases of knees and hip joint functions of the femoral or tibial fracture and shoulder functions of the humeral fractures were observed. The interlocking intramedullary nails may be considered as an alternative method for isolated diaphyseal fractures of the extremities. The advantages of this method include small operative scars, reliable fixations, better fracture healings, and fewer complications.

  18. Excellent long-term results of the Müller acetabular reinforcement ring in primary total hip arthroplasty

    PubMed Central

    Sirka, Aurimas; Clauss, Martin; Tarasevicius, Sarunas; Wingstrand, Hans; Stucinskas, Justinas; Robertsson, Otto; Emil Ochsner, Peter; Ilchmann, Thomas

    2016-01-01

    Background and purpose — The original Müller acetabular reinforcement ring (ARR) shows favorable medium-term results for acetabular reconstruction in total hip arthroplasty, where it is used when the acetabular bone stock is deficient. However, there are no data regarding long-term survival of the device. We therefore investigated long-term survival and analyzed radiological modes of failure. Patients and methods — Between 1984 and 2002, 321 consecutive primary arthroplasties using an ARR were performed in 291 patients. The mean follow-up time was 11 (0–25) years, and 24 hips were lost to follow-up. For survival analysis, we investigated 321 hips and the end of the follow-up was the date of revision, date of death, or the last patient contact date with implant still in situ. Radiological assessment was performed for 160 hips with a minimum of 10 years of follow-up and with radiographs of sufficient quality. It included evaluation of osteolysis, migration, and loosening. Results — 12 ARR THAs were revised: 1 isolated ARR revision for aseptic loosening, 4 revisions of the ARR and the stem for aseptic loosening, 6 for infection, and 1 for recurrent dislocation. The cumulative revision rate for all components, for any reason, at 20 years was 15% (95% CI: 10–22), while for the ARR only it was 7% (95% CI: 4–12) for any reason and 3.4% (95% CI: 1–9) for aseptic loosening. 21 (13%) of 160 ARR THAs examined had radiological changes: 7 had osteolysis but were not loose, and 14 were radiologically loose but were not painful and not revised. Interpretation — Our data suggest that the long-term survival of the ARR is excellent. PMID:26471881

  19. Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components.

    PubMed

    Takahashi, Yasuhito; Tateiwa, Toshiyuki; Shishido, Takaaki; Masaoka, Toshinori; Kubo, Kosuke; Yamamoto, Kengo

    2016-10-01

    The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs).

  20. Are Carotid Stent Fractures Clinically Significant?

    SciTech Connect

    Garcia-Toca, Manuel; Rodriguez, Heron E.; Naughton, Peter A.; Keeling, Aiofee; Phade, Sachin V.; Morasch, Mark D.; Kibbe, Melina R.; Eskandari, Mark K.

    2012-04-15

    Purpose: Late stent fatigue is a known complication after carotid artery stenting (CAS) for cervical carotid occlusive disease. The purpose of this study was to determine the prevalence and clinical significance of carotid stent fractures. Materials and Methods: A single-center retrospective review of 253 carotid bifurcation lesions treated with CAS and mechanical embolic protection from April 2001 to December 2009 was performed. Stent integrity was analyzed by two independent observers using multiplanar cervical plain radiographs with fractures classified into the following types: type I = single strut fracture; type II = multiple strut fractures; type III = transverse fracture; and type IV = transverse fracture with dislocation. Mean follow-up was 32 months. Results: Follow-up imaging was completed on 106 self-expanding nitinol stents (26 closed-cell and 80 open-cell stents). Eight fractures (7.5%) were detected (type I n = 1, type II n = 6, and type III n = 1). Seven fractures were found in open-cell stents (Precise n = 3, ViVEXX n = 2, and Acculink n = 2), and 1 fracture was found in a closed-cell stent (Xact n = 1) (p = 0.67). Only a previous history of external beam neck irradiation was associated with fractures (p = 0.048). No associated clinical sequelae were observed among the patients with fractures, and only 1 patient had an associated significant restenosis ({>=}80%) requiring reintervention. Conclusions: Late stent fatigue after CAS is an uncommon event and rarely clinically relevant. Although cell design does not appear to influence the occurrence of fractures, lesion characteristics may be associated risk factors.

  1. The treatment of symptomatic osteoporotic spinal compression fractures.

    PubMed

    Esses, Stephen I; McGuire, Robert; Jenkins, John; Finkelstein, Joel; Woodard, Eric; Watters, William C; Goldberg, Michael J; Keith, Michael; Turkelson, Charles M; Wies, Janet L; Sluka, Patrick; Boyer, Kevin M; Hitchcock, Kristin

    2011-03-01

    This clinical practice guideline is based on a series of systematic reviews of published studies on the treatment of symptomatic osteoporotic spinal compression fractures. Of 11 recommendations, one is strong; one, moderate; three, weak; and six, inconclusive. The strong recommendation is against the use of vertebroplasty to treat the fractures; the moderate recommendation is for the use of calcitonin for 4 weeks following the onset of fracture. The weak recommendations address the use of ibandronate and strontium ranelate to prevent additional symptomatic fractures, the use of L2 nerve root blocks to treat the pain associated with L3 or L4 fractures, and the use of kyphoplasty to treat symptomatic fractures in patients who are neurologically intact.

  2. TREATMENT OF DIFFICULT AND INVOLVED COLLES' FRACTURES

    PubMed Central

    Cox, Francis J.; Meier, August W.

    1951-01-01

    Of 105 cases of Colles' fracture, 86 were treated by closed reduction and plaster immobilization alone; 19 cases in which the fractures were more severe were treated by fixed skeletal traction using an external skeletal traction splint. Despite the greater severity of the lesions, the end results, both anatomic and functional, were generally better in those cases in which skeletal traction was used than in those treated by closed reduction. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9.Figure 10.Figure 11.Figure 12.Figure 13. PMID:14801716

  3. Simultaneous Bilateral Fracture Dislocation of the Talus: A Case Report

    PubMed Central

    Taraz-Jamshidi, Mohammad Hosein; Shapari, Omid; Shiravani, Reza; Moalemi, Saeed; Birjandinejad, Ali

    2013-01-01

    Introduction Fracture - dislocations of the talus are typically due to high energy injuries. Displaced fracture - dislocations of the talus have poor outcomes in general and complications are common. Although talar fracture is common and comprises the second most common tarsal fracture, bilateral fracture - dislocations of the talus are rare. Not many reports regarding the subject can be found in the literature. Case Presentation We report a patient with bilateral fracture - dislocations of the talus treated by open reduction and internal fixation. This patient was a 25 year-old man who sustained bilateral fracture - dislocation of the talus due to a motor vehicle accident. Conclusions Bilateral talar fracture - dislocation is rare. The surgical approach discussed together with the pathomechanics of this injury can yield good short term results. PMID:24350160

  4. [Fractures of the tibial shaft].

    PubMed

    Märdian, S; Schwabe, P; Schaser, K-D

    2015-02-01

    The tibia shaft is the most often fractured long bone of human beings. Among others traffic accidents (37.5 %), falls (17.8 %), sport accidents (30.9 %) and assaults (4.5 %) are typical mechanisms. A brief clinical examination including the correct classification of the fracture pattern and even more important the degree of the soft tissue damage are the most crucial factors for the following therapeutic cascade. This follows a defined algorithm based on the degree of soft tissue damage. As biplanar X-ray diagnostics are obligatory, CT scans are subject to complex fracture patterns and accompanying intraarticular pathologies.The treatment of tibial shaft fractures is the preserve of operative stabilization, which should be done primarily depending on the degree of the soft tissue injury. Here intramedullary methods - especially intramedullary nailing - are the golden standard.The most serious complication of these fractures is the development of a compartment syndrome. This requires rapid diagnosis and an adequate surgical management in order to avoid extensive muscle necrosis with ischaemic contractures and irreversible neurovascular deficits. Apart from postoperative infections, which are the predominant complication especially in open injuries, non union provide typical and late complications which are partly difficult to treat. These should, depending on their type, follow a dedicated treatment algorithm.

  5. Clinical Analysis of Midfacial Fractures

    PubMed Central

    Yamamoto, Kazuhiko; Matsusue, Yumiko; Horita, Satoshi; Murakami, Kazuhiro; Sugiura, Tsutomu; Kirita, Tadaaki

    2014-01-01

    Purpose: To analyze the features of midfacial fractures. Methods: Data of 320 patients treated for midfacial fractures during the past 10 years were retrospectively analyzed. Results: Patients were 192 male and 128 female. Their age ranged from 1 to 96 years old with the average of 42.1. Injury most frequently occurred by traffic accidents in 168 patients, followed by falls in 78, assaults in 31 and sports in 25. Pattern of the fractures was classified into zygoma in 159 patients, alveolus in 60, multiple sites in 54, maxilla in 45 and nasal bone in 2. Facial injury severity scale ranged from 1 to 12 with the average of 1.52. Injuries to other sites of the body were found in 90 patients. Fractures of multiple sites showed higher facial injury severity scale and were associated with injuries to other sites of the body at a higher rate. Observation was most frequently chosen in 153 patients, followed by open reduction and internal fixation in 72, intramaxillary fixation in 43 and transcutaneous reduction in 26. Conclusions: Midfacial fractures showed a variety of features in terms of the site and severity and associated injuries. Understanding these features is important to manage these patients properly. PMID:24757396

  6. Surfactant-driven fracture of gels: Growth

    NASA Astrophysics Data System (ADS)

    Daniels, Karen; Schillaci, Mark; Bostwick, Joshua

    2012-11-01

    A droplet of surfactant spreading on a gel substrate can produce fractures on the gel surface, which originate at the contact-line and propagate outwards in a star-burst pattern. Fractures have previously been observed to initiate through a thermal process, with the number of fractures controlled by the ratio of surface tension differential to gel shear modulus. After the onset of fracture, experiments show the arm length grows with universal power law L =t 3 / 4 that does not scale with any material parameters (Daniels et al. 2007, PRL), including super-spreading surfactants (Spandangos et al. 2012, Langmuir). We develop a model for crack growth controlled by the transport of an inviscid fluid into the fracture tip. While treating the gel as a linear material correctly predicts power-law growth, we find that only by considering a Neo-Hookean (incompressible) material do we obtain agreement with the experiments.

  7. The Use of Iliac Stem Prosthesis for Acetabular Defects following Resections for Periacetabular Tumors

    PubMed Central

    De Paolis, Massimiliano; Romagnoli, Carlo; Alì, Nikolin; Giannini, Sandro; Donati, Davide Maria

    2013-01-01

    Introduction. The management of pelvic tumors is a challenge for orthopaedic oncologists due to the complex anatomy of the pelvis and the need to have extensive exposure. Various reconstructive techniques have been proposed with poor functional results and a high percentage of complications. Our purpose is to determine the functional results and the rate of complications of iliac stem prosthesis for acetabular defects following resections for periacetabular tumors. Materials and Methods. Between 1999 and 2012, 45 patients underwent pelvic resections for periacetabular bone tumors followed by reconstruction with stem cup prosthesis. The most common diagnosis was CS (chondrosarcoma, 29 cases), followed by OS (osteosarcoma, 9 cases) and metastasis (3 cases). In 33 cases, this implant was associated with massive bone allografts. Minimum follow-up required to evaluate functional outcome was 2 years. We classified pelvic resections according to Enneking and Dunham's classification and we used MSTS (musculoskeletal tumor system) score to evaluate functional outcomes. Results and Discussion. Sixteen patients died of their disease, three were lost to follow-up, four are alive with disease, and twenty-two are alive with no evidence of disease. Fifteen patients had local recurrence. Sixteen patients had bone or lung metastasis. We have had 6 infections, 2 aseptic loosening, and 2 cases of hip dislocation. Iliac sovracetabular osteotomy was fused in all cases at 10 months from surgery. Functional results were good or excellent in 25 of 31 patients with long-term follow-up (77%), with a percentage similar to that reported in the literature. Conclusion. The use of iliac stem prosthesis is a simple reconstructive technique that reduces operative times and risk of infection. It allows having good results and low rate of complications, but it should be performed in selected cases and centres of reference. PMID:24250275

  8. Effect of Natural Fractures on Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Ben, Y.; Wang, Y.; Shi, G.

    2012-12-01

    Hydraulic Fracturing has been used successfully in the oil and gas industry to enhance oil and gas production in the past few decades. Recent years have seen the great development of tight gas, coal bed methane and shale gas. Natural fractures are believed to play an important role in the hydraulic fracturing of such formations. Whether natural fractures can benefit the fracture propagation and enhance final production needs to be studied. Various methods have been used to study the effect of natural fractures on hydraulic fracturing. Discontinuous Deformation Analysis (DDA) is a numerical method which belongs to the family of discrete element methods. In this paper, DDA is coupled with a fluid pipe network model to simulate the pressure response in the formation during hydraulic fracturing. The focus is to study the effect of natural fractures on hydraulic fracturing. In particular, the effect of rock joint properties, joint orientations and rock properties on fracture initiation and propagation will be analyzed. The result shows that DDA is a promising tool to study such complex behavior of rocks. Finally, the advantages of disadvantages of our current model and future research directions will be discussed.

  9. Fracture channel waves

    NASA Astrophysics Data System (ADS)

    Nihei, Kurt T.; Yi, Weidong; Myer, Larry R.; Cook, Neville G. W.; Schoenberg, Michael

    1999-03-01

    The properties of guided waves which propagate between two parallel fractures are examined. Plane wave analysis is used to obtain a dispersion equation for the velocities of fracture channel waves. Analysis of this equation demonstrates that parallel fractures form an elastic waveguide that supports two symmetric and two antisymmetric dispersive Rayleigh channel waves, each with particle motions and velocities that are sensitive to the normal and tangential stiffnesses of the fractures. These fracture channel waves degenerate to shear waves when the fracture stiffnesses are large, to Rayleigh waves and Rayleigh-Lamb plate waves when the fracture stiffnesses are low, and to fracture interface waves when the fractures are either very closely spaced or widely separated. For intermediate fracture stiffnesses typical of fractured rock masses, fracture channel waves are dispersive and exhibit moderate to strong localization of guided wave energy between the fractures. The existence of these waves is examined using laboratory acoustic measurements on a fractured marble plate. This experiment confirms the distinct particle motion of the fundamental antisymmetric fracture channel wave (A0 mode) and demonstrates the ease with which a fracture channel wave can be generated and detected.

  10. Changes in hip fracture epidemiology: redistribution between ages, genders and fracture types.

    PubMed

    Löfman, O; Berglund, K; Larsson, L; Toss, G

    2002-01-01

    After several reports of increasing hip fracture incidence some studies have suggested a trend-break. In a previous study of hip fractures we forecast a 70% increase in the total number of fractures from 1985 up to year 2000. We therefore studied the incidence trend for the last 15 years and supply a new prognosis up to year 2010. We recorded all incident hip fractures treated in the county of Ostergötland, Sweden (approximately 400,000 inhabitants) 1982-96. A total of 11,517 hip fractures in men and women aged 50 years and above were included in the study after cross-validation between a computerized register of radiologic investigations and the hospital records. The projected number of fractures up to year 2010 was estimated by a Poisson regression model, considering both age and year of fracture in every single year 1982-96 for the respective fracture type and gender, and applied to the projected population. The annual number of hip fractures increased by 39% in men and 25% in women during the study period. Amongst men, the age-adjusted incidence of cervical fractures increased from 188 to 220/100,000 and of trochanteric fractures from 138 to 170/100,000. In women the incidence of cervical fractures decreased from 462/100,000 to 418/100,000 and of trochanteric fractures from 407/100,000 to 361/100,000. Cervical/trochanteric fracture incidence rate ratio leveled off, and also the female/male fracture rate ratio declined. A prognosis assuming that the incidence development will continue as during 1982-96, and a population in agreement with the forecast, predicts that the total age- and sex-adjusted number of hip fractures will decrease by 11% up to year 2010 compared with 1996. In women and men, however, a decrease of 19% and an increase of 7% respectively were projected. If the age- and sex-specific incidence remains at the same level as at the end of the study period, no significant change in the total numbers will occur. A trend-break was thus found in hip

  11. Bilateral Femoral Neck Stress Fracture Presented with Unilateral Symptoms in a Shipman Laborer: A Case Report

    PubMed Central

    Santoso, Asep; Joo, Sang-Don; Lee, Dong-Hyun; Seol, Young-Jun; Yoon, Taek-Rim

    2017-01-01

    Femoral neck stress fracture occured commonly in athlete and military recruit populations, some of them are bilateral. Bilateral femoral neck stress fracture that associated with other occupation is very uncommon. We report a bilateral femoral neck stress fracture case that presented with unilateral symptoms in a male shipman laborer. The patient was successfully treated conservatively. Stress fracture sometimes occur associated with an unexpected specific occupation. Consideration of bilateral involvement is highly important in managing stress fracture. PMID:28316966

  12. Pediatric Olecranon Fractures Associated With Radial Neck Fractures: Review and Report of Two Cases

    PubMed Central

    Gokkus, Kemal; Kose, Ozkan; Saylik, Murat; Sagtas, Ergin; Turan Aydin, Ahmet

    2016-01-01

    Introduction The debate regarding the description on classification and nomenclature of the injury which includes olecranon fracture associated with radial neck fractures in children is ongoing. We report two pediatric cases that could not be classified in a Monteggia-equivalents system and were treated with open reduction and k-wire fixation. The aim of this study was to perform a systematic review regarding pediatric radial neck fractures associated with olecranon fractures and presentation of two pediatric cases of olecranon fractures associated with radial neck fractures with radiocapitellar dislocation. Case Presentation Two boys, aged 7 and 12, came to two separate clinics on the same day after initial injury. On physical examination, the patients’ elbow range of motion was limited and painful. Their upper extremities were intact. Radiographs revealed the radial neck fracture with prominent anterolateral radiocapitellar dislocation of radial head-associated with non-displaced olecranon fracture. Radial neck fracture was reduced easily by pushing posteromedially manually with the finger and secured with two K-wires .The olecranon fracture was visualized and confirmed that it was non-displaced and secured with two k-wires in the first case and one k-wire in the second case. After 2 months of follow-up, both patients had no pain in their elbow and a full functionality with a full range of motion of the elbow. The posterior intraosseous nerve functions were normal. Conclusions The fracture of olecranon if it does not extend into the metaphyseal region; it could not fascilitate diastasis of the proximal radioulnar joint and radial head dislocation. So this type of fracture must not be addressed as a Monteggia-fracture dislocation. The description of radioulnar diastasis must be included when this type of injury is to be classified. PMID:27921015

  13. Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis.

    PubMed

    Berthonnaud, E; Hilmi, R; Dimnet, J

    2012-01-01

    The goal of this paper is to access to pelvis position and morphology in standing posture and to determine the relative locations of their articular surfaces. This is obtained from coupling biplanar radiography and bone modeling. The technique involves different successive steps. Punctual landmarks are first reconstructed, in space, from their projected images, identified on two orthogonal standing X-rays. Geometric models, of global pelvis and articular surfaces, are determined from punctual landmarks. The global pelvis is represented as a triangle of summits: the two femoral head centers and the sacral plateau center. The two acetabular cavities are modeled as hemispheres. The anterior sacral plateau edge is represented by an hemi-ellipsis. The modeled articular surfaces are projected on each X-ray. Their optimal location is obtained when the projected contours of their models best fit real outlines identified from landmark images. Linear and angular parameters characterizing the position of global pelvis and articular surfaces are calculated from the corresponding sets of axis. Relative positions of sacral plateau, and acetabular cavities, are then calculated. Two hundred standing pelvis, of subjects and scoliotic patients, have been studied. Examples are presented. They focus upon pelvis orientations, relative positions of articular surfaces, and pelvis asymmetries.

  14. Theoretical Implications of Periacetabular Osteotomy in Various Dysplastic Acetabular Cartilage Defects as Determined by Finite Element Analysis

    PubMed Central

    Xu, Meng; Qu, Wenrui; Wang, Yanbing; Zhong, Lei; Zhu, Zhe; Li, Wei; Zhao, Xin; Wang, Jincheng; Sun, Yu

    2016-01-01

    Background Different extents and locations of acetabular cartilage defect have been supposed to be a major cause of undesirable outcomes of periacetabular osteotomy (PAO) in patients with developmental dysplasia of the hip (DDH). This study aimed to verify whether different locations of cartilage deficiency affect the biomechanical environment in a three-dimensional model utilizing finite element analysis (FEA). Material/Methods We developed 3 DDH models – DDH-1 (normal shape), DDH-2 (superior defect), and DDH-3 (anterosuperior defect) – by deforming from a normal hip model. We also developed 3 PAO models – PAO-1, PAO-2, and PAO-3 – through rotating osteotomized fragments. Results The maximum von Mises stress in the normal hip was 13.06 MPa. In the DDH-1 model, the maximum value on the load-bearing area decreased from 15.49 MPa pre-PAO to 14.28 MPa post-PAO, while stresses in the DDH-2 and DDH-3 models were higher than in the DDH-1 model, both pre-PAO and post-PAO (30.46 MPa to 26.04 MPa for DDH-2; 33.89 MPa to 27.48 MPa for DDH-3). Conclusions This study shows that, both pre- and post-PAO, different types of cartilage deficiency affect the biomechanical environment. Furthermore, in dysplastic hips, obtaining accurate three-dimensional information about the acetabular cartilage can contribute substantially to PAO decision making. PMID:28017958

  15. Hip flexor muscle size, strength and recruitment pattern in patients with acetabular labral tears compared to healthy controls.

    PubMed

    Mendis, M Dilani; Wilson, Stephen J; Hayes, David A; Watts, Mark C; Hides, Julie A

    2014-10-01

    Acetabular labral tears are a source of hip pain and are considered to be a precursor to hip osteoarthritis. Hip flexor muscles contribute to hip joint stability and function but it is unknown if their size and function is altered in the presence of labral pathology. This study aimed to investigate hip flexor muscle size, strength and recruitment pattern in patients with hip labral pathology compared to control subjects. 12 subjects diagnosed with an unilateral acetabular labral tear were compared to 12 control subjects matched for age and gender. All subjects underwent magnetic resonance imaging (MRI) of their lumbo-pelvic region. Average muscle cross-sectional area (CSA) of the iliacus, psoas, iliopsoas, sartorius, tensor fascia latae and rectus femoris muscles were measured. Hip flexion strength was measured by an externally fixed dynamometer. Individual muscle recruitment pattern during a resisted hip flexion exercise task was measured by muscle functional MRI. Hip flexor muscle strength was found to be decreased in patients with labral pathology compared to control subjects (p < 0.01). No difference between groups or sides was found for hip flexor muscle size (all p > 0.17) and recruitment pattern (all p > 0.53). Decreased hip flexor muscle strength may affect physical function in patients with hip labral pathology by contributing to altered gait patterns and functional tasks. Clinical rehabilitation of these patients may need to include strengthening exercises for the hip flexor muscles.

  16. Highly Cross-linked Polyethylene Liner Dissociation from a Cement-less Modular Acetabular Shell: Two Case Reports

    PubMed Central

    Kawano, Shunsuke; Sonohata, Motoki; Kitajima, Masaru; Mawatari, Masaaki

    2016-01-01

    Liner dissociation of polyethylene from a cementless acetabular socket following total hip arthroplasty (THA) is a rare complication. Cross-linked polyethylene liner dissociation from AMS-HA shell (KYOCERA Med, Osaka, Japan) occurred in 2 out of the 4153 (0.04%) cases approximately 10 years after undergoing surgery at our institute. First case was an 80-year-old female who underwent right THA along with subtrochanteric femoral shortening osteotomy due to complete dislocation hip, and second case was a 72-year-old male, who underwent right THA due to coxarthrosis. A 26 mm femoral head and CPE liner were used in both cases and the inclination degree of the acetabular socket was within 50°.There was no implant loosening in both cases. There was partial damage in the elevated rim on the alternative side and scratches on the back side in the both extracted CPE liner. It was surmised that liner dissociation was caused due to a problem in the liner fixing format of the push in type of the present model. PMID:28217197

  17. Highly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: a report of two cases.

    PubMed

    Teeter, Matthew G; Naudie, Douglas D R; Charron, Kory D; Holdsworth, David W

    2010-08-01

    There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved between four to five years after implantation. The two XLPE acetabular liners (Reflection, Smith and Nephew Inc., Memphis, TN) were retrieved from patients undergoing their second revision surgery, at 4.90 and 4.07 years. The retrieved liners and a new, non-implanted, unworn liner of the same size were scanned using micro-computed tomography (micro-CT). Articular surface deviation maps were created by comparing the retrievals to the unworn liner, based on the liner geometry obtained from micro-CT. The linear penetration rates were found to be 0.018 and 0.008 mm/year. Localized scratches and pits with deviations greater than 0.205 mm were also found on the articular surfaces of both liners. The XLPE liners retrieved from the two cases demonstrated low linear penetration rates. Regions with greater focal deviations were also apparent, likely due to third-body wear. The results are consistent with previously published clinical follow-ups of other XLPE liners.

  18. Triplane fracture of the distal radius.

    PubMed

    García-Mata, Serafín; Hidalgo-Ovejero, Angel

    2006-07-01

    A case of triplane fracture of the distal radius is reported in a 13-year-old boy. This exceptional fracture showed displacement, and was healed by closed reduction and 6 weeks of external immobilization. Eighteen months later, the patient showed complete physeal arrest of the distal radius, with radio-ulnar length discrepancy but without any repercussion on wrist mobility. The patient was declared asymptomatic 3 years after the injury. Prompt, physiological physeal arrest reduces the potential of growth deformity. These fractures must be treated conservatively by closed reduction (if displacement exists) and external immobilization, just like a normal one-plane fracture. We may suppose that final radio-ulnar discrepancy could lead to a painful and symptomatic ulno-carpal conflict in adult life. The following characteristics can be associated with this rare fracture: (1) occurrence close to the end of the growth period, as in other types of triplane fractures; (2) evolution towards partial or complete growth arrest of the physis, not requiring treatment and (3) stability of the fracture after closed reduction. In the present case, as in the other reported cases, it may also be added that orthopaedic treatment has been the rule, in contrast with triplane fractures occurring in the distal tibia, in which surgical treatment is indicated.

  19. Splinting of Longitudinal Fracture: An Innovative Approach.

    PubMed

    Bansal, Rashmi; Chowdhary, Priyanka; Gurtu, Anuraag; Mehrotra, Nakul; Kishore, Abhinav

    2016-01-01

    Trauma may result in craze lines on the enamel surface, one or more fractured cusps of posterior teeth, cracked tooth syndrome, splitting of posterior teeth, and vertical fracture of root. Out of these, management of some fractures is of great challenge and such teeth are generally recommended for extraction. Literature search reveals attempts to manage such fractures by full cast crown, orthodontic wires, and so forth, in which consideration was given to extracoronal splinting only. However, due to advancement in materials and technologies, intracoronal splinting can be achieved as well. In this case report, longitudinal fractures in tooth #27, tooth #37, and tooth #46 had occurred. In #27, fracture line was running mesiodistally involving the pulpal floor resulting in a split tooth. In teeth 37 and 46, fractures of the mesiobuccal cusp and mesiolingual cusp were observed, respectively. They were restored with cast gold inlay and full cast crown, respectively. Longitudinal fracture of 27 was treated with an innovative approach using intracanal reinforced composite with Ribbond, external reinforcement with an orthodontic band, and full cast metal crown to splint the split tooth.

  20. Analysis of Fractured Mandible Over Two Decades

    PubMed Central

    Oruç, Melike; Işik, Veysel Murat; Kankaya, Yüksel; Gürsoy, Koray; Sungur, Nezih; Aslan, Gürcan; Koçer, Uğur

    2016-01-01

    Abstract Mandible fractures have a special place within the injuries of the other bones of the maxillofacial system. In their management, cosmetic issues and functional aspects such as chewing, speaking, and swallowing become very important. In this study, a retrospective analysis of 419 mandible fractures in 283 patients was performed in relation to epidemiologic factors, treatment strategies, and complications. The average age was 32.14 years (4–69 years). The male/female ratio was 4/1. The most frequent etiologic factor was interpersonal violence (104 patients, 36.7%). The parasymphysis region was the mostly affected site (28.4%). A total of 157 patients (55.5%) were presented with single fracture and the rest with 2, 3, or 4 fracture lines on the mandible. The most common fracture combination was angulus–parasymphysis fracture combination (24.6%). Open reduction and fixation with mini plates and screws was the most preferred treatment strategy (48.2%). Transient short arch bars were not used intraoperatively for any of the patients. There was not any difference in terms of complications between the patients treated with plating systems and plating systems plus intermaxillary fixation. In conclusion, proper treatment of mandible fractures is critical. Except certain fracture types, the usage of intermaxillary fixation as an adjunct to fixation with plating systems is not necessary. PMID:27536913

  1. Splinting of Longitudinal Fracture: An Innovative Approach

    PubMed Central

    Bansal, Rashmi; Chowdhary, Priyanka; Gurtu, Anuraag; Mehrotra, Nakul; Kishore, Abhinav

    2016-01-01

    Trauma may result in craze lines on the enamel surface, one or more fractured cusps of posterior teeth, cracked tooth syndrome, splitting of posterior teeth, and vertical fracture of root. Out of these, management of some fractures is of great challenge and such teeth are generally recommended for extraction. Literature search reveals attempts to manage such fractures by full cast crown, orthodontic wires, and so forth, in which consideration was given to extracoronal splinting only. However, due to advancement in materials and technologies, intracoronal splinting can be achieved as well. In this case report, longitudinal fractures in tooth #27, tooth #37, and tooth #46 had occurred. In #27, fracture line was running mesiodistally involving the pulpal floor resulting in a split tooth. In teeth 37 and 46, fractures of the mesiobuccal cusp and mesiolingual cusp were observed, respectively. They were restored with cast gold inlay and full cast crown, respectively. Longitudinal fracture of 27 was treated with an innovative approach using intracanal reinforced composite with Ribbond, external reinforcement with an orthodontic band, and full cast metal crown to splint the split tooth. PMID:27247808

  2. Paratrooper's Ankle Fracture: Posterior Malleolar Fracture

    PubMed Central

    Young, Ki Won; Cho, Jae Ho; Kim, Hyung Seuk; Cho, Hun Ki; Lee, Kyung Tai

    2015-01-01

    Background We assessed the frequency and types of ankle fractures that frequently occur during parachute landings of special operation unit personnel and analyzed the causes. Methods Fifty-six members of the special force brigade of the military who had sustained ankle fractures during parachute landings between January 2005 and April 2010 were retrospectively analyzed. The injury sites and fracture sites were identified and the fracture types were categorized by the Lauge-Hansen and Weber classifications. Follow-up surveys were performed with respect to the American Orthopedic Foot and Ankle Society ankle-hindfoot score, patient satisfaction, and return to preinjury activity. Results The patients were all males with a mean age of 23.6 years. There were 28 right and 28 left ankle fractures. Twenty-two patients had simple fractures and 34 patients had comminuted fractures. The average number of injury and fractures sites per person was 2.07 (116 injuries including a syndesmosis injury and a deltoid injury) and 1.75 (98 fracture sites), respectively. Twenty-three cases (41.07%) were accompanied by posterior malleolar fractures. Fifty-five patients underwent surgery; of these, 30 had plate internal fixations. Weber type A, B, and C fractures were found in 4, 38, and 14 cases, respectively. Based on the Lauge-Hansen classification, supination-external rotation injuries were found in 20 cases, supination-adduction injuries in 22 cases, pronation-external rotation injuries in 11 cases, tibiofibular fractures in 2 cases, and simple medial malleolar fractures in 2 cases. The mean follow-up period was 23.8 months, and the average follow-up American Orthopedic Foot and Ankle Society ankle-hindfoot score was 85.42. Forty-five patients (80.36%) reported excellent or good satisfaction with the outcome. Conclusions Posterior malleolar fractures occurred in 41.07% of ankle fractures sustained in parachute landings. Because most of the ankle fractures in parachute injuries were

  3. Management of metacarpal fractures.

    PubMed

    McNemar, Thomas B; Howell, Julianne Wright; Chang, Eric

    2003-01-01

    Fractures of the hand are the most common fractures of the human skeleton. Metacarpal fractures account for 30% to 50% of all of hand fractures. The mechanisms of these injuries vary from axial loading forces to direct blows to the dorsal hand. Resulting deformities include malrotation, angulation, and shortening. Treatment modalities vary from nonoperative reduction to open reduction and internal fixation. The treatment algorithm is guided by the location of the fracture, the stability of the fracture, and the resultant deformity. Operative procedures, although they may lead to excellent radiographic reduction of fractures, often lead to debilitating stiffness from the inflammatory reaction of the surgical procedure. Operative fixation must be employed judiciously and offered only when confident that non-operative therapy can be improved on with operative intervention. This article reviews the various types of metacarpal fractures, with the treatment options available for each fracture. The indications for each treatment modality, postoperative care, and rehabilitation are presented.

  4. Compartment syndrome of the thigh complicating surgical treatment of ipsilateral femur and ankle fractures

    NASA Technical Reports Server (NTRS)

    Moore, M. R.; Garfin, S. R.; Hargens, A. R.

    1987-01-01

    A 26-year-old man presented with ipsilateral femur and ankle fractures. The patient was treated with interlocking nail of his femur fracture, followed by open reduction and internal fixation of his ankle fracture under tourniquet control. Postoperatively, the patient developed compartment syndrome of his thigh with elevated pressures, requiring decompressive fasciotomies. This case illustrates the possible complication of treating a femur fracture with intramedullary nailing and then immediately applying a tourniquet to treat an ipsilateral extremity fracture. Because of the complication with this patient, we feel the procedure should be staged, or a tourniquet should be avoided if possible.

  5. The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups – finite element simulations and experimental tests

    PubMed Central

    Korhonen, Rami K; Koistinen, Arto; Konttinen, Yrjö T; Santavirta, Seppo S; Lappalainen, Reijo

    2005-01-01

    Background Contact pressure of UHMWPE acetabular cup has been shown to correlate with wear in total hip replacement (THR). The aim of the present study was to test the hypotheses that the cup geometry, abduction angle, thickness and clearance can modify the stresses in cemented polyethylene cups. Methods Acetabular cups with different geometries (Link®: IP and Lubinus eccentric) were tested cyclically in a simulator at 45° and 60° abduction angles. Finite element (FE) meshes were generated and two additional designs were reconstructed to test the effects of the cup clearance and thickness. Contact pressures at cup-head and cup-cement interfaces were calculated as a function of loading force at 45°, 60° and 80° abduction angles. Results At the cup-head interface, IP experienced lower contact pressures than the Lubinus eccentric at low loading forces. However, at higher loading forces, much higher contact pressures were produced on the surface of IP cup. An increase in the abduction angle increased contact pressure in the IP model, but this did not occur to any major extent with the Lubinus eccentric model. At the cup-cement interface, IP experienced lower contact pressures. Increased clearance between cup and head increased contact pressure both at cup-head and cup-cement interfaces, whereas a decreased thickness of polyethylene layer increased contact pressure only at the cup-cement interface. FE results were consistent with experimental tests and acetabular cup deformations. Conclusion FE analyses showed that geometrical design, thickness and abduction angle of the acetabular cup, as well as the clearance between the cup and head do change significantly the mechanical stresses experienced by a cemented UHMWPE acetabular cup. These factors should be taken into account in future development of THR prostheses. FE technique is a useful tool with which to address these issues. PMID:15904521

  6. On material fracture criteria

    NASA Astrophysics Data System (ADS)

    Kremnev, L. S.

    2017-01-01

    Based on the nonlinear mechanics of material fracture, a model of the fracture of materials with actual (discrete) structures has been constructed. The model is supported by proofs that crack resistance K 1 c and fracture toughness G 1 c obtained from the energy conservation law without using the assumptions adopted in the linear material fracture mechanics serve as the force and energy criteria in the nonlinear fracture mechanics. It has been shown that energy criterion G 1 c in the nonlinear mechanics is much greater than G 1 c in the linear fracture mechanics.

  7. [Therapy principles of distal fractures of the forearm in childhood].

    PubMed

    Laurer, H; Sander, A; Wutzler, S; Walcher, F; Marzi, I

    2009-11-01

    Fractures of the forearm in children represent one of the most frequent injuries. Most are monotraumatic occurring during sport or leisure activities. Diagnosis can be made by conventional X-ray examination in 2 planes. Distal forearm fractures are classified into epiphyseolysis and epiphyseal fractures, metaphyseal greenstick and buckle fractures, complete distal radius and forearm fractures as well as Galeazzi lesions. The vast majority of cases without relevant dislocation can be treated with immobilization employing a cast. The remaining fractures have to be repositioned and restored depending on age and degree of dislocation.The state of the art in surgical therapy is the Kirschner wire osteosynthesis after closed reduction. Especially meta-diaphyseal fractures can alternatively be stabilized with plate osteosynthesis or external fixation. Following these therapeutic principles, prognosis is excellent and most of the injuries heal without any functional impairment.

  8. Surgical management of metastatic long bone fractures: principles and techniques.

    PubMed

    Scolaro, John Alan; Lackman, Richard D

    2014-02-01

    Management of metastatic long bone fractures requires identification of the lesion and the use of sound fracture fixation principles to relieve pain and restore function. The treating surgeon must understand the principles of pathologic fracture fixation before initiating treatment. Because these fractures occur in the context of a progressive systemic disease, management typically involves a multidisciplinary approach. When considering surgical stabilization of these fractures, the abnormal (or absent) healing environment associated with diseased bone and the overall condition of the patient must be taken into account. The goal of surgery is to obtain a rigid mechanical construct, which allows for early mobility and weight bearing. This can be achieved using internal fixation with polymethyl methacrylate cement or segmental resection and joint reconstruction. Prosthetic joint arthroplasty is a more reliable means of fracture management when insufficient bone is present for fixation. Prophylactic stabilization of impending pathologic fractures can reduce the morbidity associated with metastatic lesions.

  9. Current concepts for the treatment of acute scaphoid fractures.

    PubMed

    Arsalan-Werner, A; Sauerbier, M; Mehling, I M

    2016-02-01

    Fractures of the scaphoid are common injuries, accounting for approximately 80 % of carpal fractures. Differentiation between stable and unstable fractures (Herbert classification) cannot be made with conventional X-rays, so evaluation by computed tomography should additionally be performed. Under most circumstances, minimally invasive surgery with cannulated screws is the treatment of choice. A longer cast immobilization after minimal-invasive surgery is not necessary. Conservative treatment still has a place if the fracture is not dislocated nor unstable, but operative treatment can be offered to reduce the period of cast immobilization. Displaced fractures have a greater risk for nonunion and therefore should be treated operatively. Proximal pole fractures are definitely unstable, requiring treatment with screw fixation. The surgical approach depends on the location of the fracture and the preference of the surgeon.

  10. C2 Fracture Subtypes, Incidence, and Treatment Allocation Change with Age: A Retrospective Cohort Study of 233 Consecutive Cases

    PubMed Central

    Möller, Anders; Olerud, Claes

    2017-01-01

    The currently available data on the distribution of C2 fracture subtypes is sparse. This study was designed to identify the proportions of the second cervical vertebra (C2) fracture subtypes and to present age and gender specific incidences of subgroups. A dataset of all patients treated between 2002 and 2014 for C2 fractures was extracted from the regional hospital information system. C2 fractures were classified into odontoid fractures types 1, 2, and 3, Hangman's fractures types 1, 2, and 3, and atypical C2 fractures. 233 patients (female 51%, age 72 ± 19 years) were treated for a C2 fracture. Odontoid fractures were found in 183 patients, of which 2 were type 1, 127 type 2, and 54 type 3, while 26 of C2 fractures were Hangman's fractures and 24 were atypical C2 fractures. In the geriatric subgroup 89% of all C2 fractures were odontoid, of which 71% were type 2 and 29% type 3. There was an increasing incidence of odontoid fractures types 2 and 3 from 2002 to 2014. 40% of C2 fractures were treated surgically. This study presents reliable subset proportions of C2 fractures in a prospectively collected regional cohort. Knowledge of these proportions facilitates future epidemiological studies of C2 fractures. PMID:28182084

  11. C2 Fracture Subtypes, Incidence, and Treatment Allocation Change with Age: A Retrospective Cohort Study of 233 Consecutive Cases.

    PubMed

    Robinson, Anna-Lena; Möller, Anders; Robinson, Yohan; Olerud, Claes

    2017-01-01

    The currently available data on the distribution of C2 fracture subtypes is sparse. This study was designed to identify the proportions of the second cervical vertebra (C2) fracture subtypes and to present age and gender specific incidences of subgroups. A dataset of all patients treated between 2002 and 2014 for C2 fractures was extracted from the regional hospital information system. C2 fractures were classified into odontoid fractures types 1, 2, and 3, Hangman's fractures types 1, 2, and 3, and atypical C2 fractures. 233 patients (female 51%, age 72 ± 19 years) were treated for a C2 fracture. Odontoid fractures were found in 183 patients, of which 2 were type 1, 127 type 2, and 54 type 3, while 26 of C2 fractures were Hangman's fractures and 24 were atypical C2 fractures. In the geriatric subgroup 89% of all C2 fractures were odontoid, of which 71% were type 2 and 29% type 3. There was an increasing incidence of odontoid fractures types 2 and 3 from 2002 to 2014. 40% of C2 fractures were treated surgically. This study presents reliable subset proportions of C2 fractures in a prospectively collected regional cohort. Knowledge of these proportions facilitates future epidemiological studies of C2 fractures.

  12. Pediatric Hip Fractures in California: Results from a Community-Based Hip Fracture Registry

    PubMed Central

    Prentice, Heather A; Paxton, Elizabeth W; Hunt, Jessica J; Grimsrud, Christopher D; Weiss, Jennifer M

    2017-01-01

    Context: Hip fracture registries offer an opportunity to identify and to monitor patients with rare conditions and outcomes, including hip fractures in pediatric patients. Objective: To report patient demographics and surgical outcomes of pediatric patients treated surgically for hip fractures in a large integrated health care system. Design: Pediatric patients (< 21 years old at the time of fracture) with hip fractures were identified between 2009 and 2012 using our health care system’s hip fracture registry. Main Outcome Measures: Patient characteristics, type of fracture, surgical treatment, and short-term complications. Results: Among 39 patients identified, 31 (79.5%) were male, and the median age was 15 years old (interquartile range: 11–17 years). Most patients were Hispanic (n = 17, 43.6%) or white (n = 14, 35.9%). There were 8 patients (20.5%) with 15 comorbidities. Delbet Type IV (intertrochanteric) fractures were the most common fracture type (n = 22, 56.4%), and fixation method was equally distributed between intramedullary, screw and sideplate, and screws (n = 12, 30.8% for each). Most surgeries were performed by medium-volume surgeons (n = 22, 56.4%) at medium- and high-volume hospitals (n = 37, 94.9%). Three 90-day readmissions (7.7%), 1 infection (2.6%), 1 malunion (2.6%), and 1 revision (2.6%) were observed in this cohort during the study period. Conclusion: In our series using registry data, hip fractures younger than age 21 years were more common in boys and Hispanic patients. Intertrochanteric fractures (Delbet Type IV) were the most frequently observed type in our community-based hip fracture registry. Short-term complications were infrequent. PMID:28241902

  13. Antibiotic Prophylaxis in Orbital Fractures

    PubMed Central

    Reiss, Benjamin; Rajjoub, Lamise; Mansour, Tamer; Chen, Tony; Mumtaz, Aisha

    2017-01-01

    Purpose: To determine whether prophylactic antibiotic use in patients with orbital fracture prevent orbital infection. Design: Retrospective cohort study. Participants: All patients diagnosed with orbital fracture between January 1, 2008 and March 1, 2014 at The George Washington University Hospital and Clinics. Main Outcome Measures: Development of orbital infection. Results: One hundred seventy-two patients with orbital fracture met our inclusion and exclusion criteria. No orbital infections were documented. Twenty subjects (12%) received no prophylactic antibiotic, and two (1%) received only one dose of antibiotics pre-operatively for surgery. For primary antibiotic, 136 subjects (79%) received oral antibiotics, and 14 (8%) received intravenous (IV) antibiotics (excluding cefazolin). Cephalexin and amoxicillin-clavulanate were the most prescribed oral antibiotics that are equally effective. Five-to-seven day courses of antibiotics had no increased infections compared to ten-to-fourteen day courses. Calculated boundaries for effectiveness of prophylactic antibiotics ranged from a Number Needed to Treat (NNT) of 75 to a Number Needed to Harm (NNH) of 198. Conclusion: Antibiotics for prevention of orbital infection in patients with orbital fractures have become widely used. Coordination between trauma teams and specialists is needed to prevent patient overmedication and antibiotic resistance. Should antibiotics be used, shorter courses and avoidance of broad spectrum agents are recommended. Additional studies are needed.

  14. Atypical tibial tuberosity fracture in an adolescent.

    PubMed

    Jalgaonkar, Azal A; Dachepalli, Sunil; Al-Wattar, Zaid; Rao, Sudhir; Kochhar, Tony

    2011-06-14

    Avulsion fractures of the tibial tuberosity are typically sustained by adolescent males during sporting activities. Tibial tuberosity avulsions with simultaneous proximal tibial epiphyseal fractures are rare injuries. We present an unusual case of Ogden type IIIA avulsion fracture of tibial tuberosity with a Salter Harris type IV posterior fracture of proximal tibial epiphysis in a 13-year-old boy. We believe that the patient sustained the tibial tuberosity avulsion during the take-off phase of a jump while playing basketball due to sudden violent contraction of the quadriceps as the knee was extending. This was then followed by the posterior Salter Harris type IV fracture of proximal tibial physis as he landed on his leg with enormous forces passing through the knee. Although standard radiographs were helpful in diagnosing the complex fracture pattern, precise configuration was only established by computed tomography (CT) scan. The scan also excluded well-recognized concomitant injuries including ligament and meniscal injuries. Unlike other reported cases, our patient did not have compartment syndrome. Anatomic reduction and stabilization with a partially threaded transepiphyseal cannulated screw and a metaphyseal screw followed by early mobilization ensured an excellent recovery by the patient.Our case highlights the importance of vigilance and a high index of suspicion for coexisting fractures or soft tissue injuries when treating avulsion fractures of tibial tuberosity. A CT scan is justified in such patients to recognize complex fracture configurations, and surgical treatment should be directed appropriately to both the fractures followed by early rehabilitation. Patients with such injuries warrant close monitoring for compartment syndrome during the perioperative period.

  15. Fractures in anisotropic media

    NASA Astrophysics Data System (ADS)

    Shao, Siyi

    Rocks may be composed of layers and contain fracture sets that cause the hydraulic, mechanical and seismic properties of a rock to be anisotropic. Coexisting fractures and layers in rock give rise to competing mechanisms of anisotropy. For example: (1) at low fracture stiffness, apparent shear-wave anisotropy induced by matrix layering can be masked or enhanced by the presence of a fracture, depending on the fracture orientation with respect to layering, and (2) compressional-wave guided modes generated by parallel fractures can also mask the presence of matrix layerings for particular fracture orientations and fracture specific stiffness. This report focuses on two anisotropic sources that are widely encountered in rock engineering: fractures (mechanical discontinuity) and matrix layering (impedance discontinuity), by investigating: (1) matrix property characterization, i.e., to determine elastic constants in anisotropic solids, (2) interface wave behavior in single-fractured anisotropic media, (3) compressional wave guided modes in parallel-fractured anisotropic media (single fracture orientation) and (4) the elastic response of orthogonal fracture networks. Elastic constants of a medium are required to understand and quantify wave propagation in anisotropic media but are affected by fractures and matrix properties. Experimental observations and analytical analysis demonstrate that behaviors of both fracture interface waves and compressional-wave guided modes for fractures in anisotropic media, are affected by fracture specific stiffness (controlled by external stresses), signal frequency and relative orientation between layerings in the matrix and fractures. A fractured layered medium exhibits: (1) fracture-dominated anisotropy when the fractures are weakly coupled; (2) isotropic behavior when fractures delay waves that are usually fast in a layered medium; and (3) matrix-dominated anisotropy when the fractures are closed and no longer delay the signal. The

  16. Metatarsal stress fractures - aftercare

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000553.htm Metatarsal stress fractures - aftercare To use the sharing features on ... that connect your ankle to your toes. A stress fracture is a break in the bone that ...

  17. Infant skull fracture (image)

    MedlinePlus

    Skull fractures may occur with head injuries. Although the skull is both tough and resilient and provides excellent ... or blow can result in fracture of the skull and may be accompanied by injury to the ...

  18. Rib fracture - aftercare

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000539.htm Rib fracture - aftercare To use the sharing features on this page, please enable JavaScript. A rib fracture is a crack or break in one or ...

  19. Forearm Fractures in Children

    MedlinePlus

    .org Forearm Fractures in Children The forearm is the part of the arm between the wrist and the elbow. It is ... two bones: the radius and the ulna. Forearm fractures are common in childhood, accounting for more than ...

  20. Pediatric Thighbone (Femur) Fracture

    MedlinePlus

    .org Thighbone (Femur) Fractures In Children Page ( 1 ) The thighbone (femur) is the largest and strongest bone in the body. It can break ... Cause Statistics The most common cause of thighbone fractures in infants under 1 year old is child ...

  1. Nasal fracture (image)

    MedlinePlus

    A nasal fracture is a break in the bone over the ridge of the nose. It usually results from a blunt ... and is one of the most common facial fracture. Symptoms of a broken nose include pain, blood ...

  2. Bone fracture repair - slideshow

    MedlinePlus

    ... page: //medlineplus.gov/ency/presentations/100077.htm Bone fracture repair - series—Indications To use the sharing features ... Go to slide 4 out of 4 Overview Fractures of the bones are classified in a number ...

  3. Femur fracture repair - discharge

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000166.htm Femur fracture repair - discharge To use the sharing features on this page, please enable JavaScript. You had a fracture (break) in the femur in your leg. It ...

  4. Lisfranc (Midfoot) Fractures

    MedlinePlus

    ... that disrupts multiple different joints and includes multiple fractures. Lisfranc injuries tend to damage the cartilage of ... include ligament strains and tears, as well as fractures and dislocations of bone (far right). (Le ) This ...

  5. Growth Plate Fractures

    MedlinePlus

    .org Growth Plate Fractures Page ( 1 ) The bones of children and adults share many of the same risks for injury. But because they ... to a unique injury called a growth plate fracture. Growth plates are areas of cartilage located near ...

  6. Hip fracture surgery

    MedlinePlus

    ... neck fracture repair; Trochanteric fracture repair; Hip pinning surgery; Osteoarthritis-hip ... You may receive general anesthesia before this surgery. This means ... spinal anesthesia. With this kind of anesthesia, medicine is ...

  7. Hydraulic Fracture Extending into Network in Shale: Reviewing Influence Factors and Their Mechanism

    PubMed Central

    Ren, Lan; Zhao, Jinzhou; Hu, Yongquan

    2014-01-01

    Hydraulic fracture in shale reservoir presents complex network propagation, which has essential difference with traditional plane biwing fracture at forming mechanism. Based on the research results of experiments, field fracturing practice, theory analysis, and numerical simulation, the influence factors and their mechanism of hydraulic fracture extending into network in shale have been systematically analyzed and discussed. Research results show that the fracture propagation in shale reservoir is influenced by the geological and the engineering factors, which includes rock mineral composition, rock mechanical properties, horizontal stress field, natural fractures, treating net pressure, fracturing fluid viscosity, and fracturing scale. This study has important theoretical value and practical significance to understand fracture network propagation mechanism in shale reservoir and contributes to improving the science and efficiency of shale reservoir fracturing design. PMID:25032240

  8. Hydraulic fracture extending into network in shale: reviewing influence factors and their mechanism.

    PubMed

    Ren, Lan; Zhao, Jinzhou; Hu, Yongquan

    2014-01-01

    Hydraulic fracture in shale reservoir presents complex network propagation, which has essential difference with traditional plane biwing fracture at forming mechanism. Based on the research results of experiments, field fracturing practice, theory analysis, and numerical simulation, the influence factors and their mechanism of hydraulic fracture extending into network in shale have been systematically analyzed and discussed. Research results show that the fracture propagation in shale reservoir is influenced by the geological and the engineering factors, which includes rock mineral composition, rock mechanical properties, horizontal stress field, natural fractures, treating net pressure, fracturing fluid viscosity, and fracturing scale. This study has important theoretical value and practical significance to understand fracture network propagation mechanism in shale reservoir and contributes to improving the science and efficiency of shale reservoir fracturing design.

  9. [Atlas burst fracture (Jefferson fracture) requiring surgical treatment after conservative treatment--report of two cases].

    PubMed

    Yamamoto, Hiromichi; Kurimoto, Masanori; Hayashi, Nakamasa; Ohmori, Tomoaki; Hirashima, Yutaka; Endo, Shunro

    2002-09-01

    Most cases of atlas burst fracture do not require surgical stabilization, because they can be successfully treated with external immobilization. The authors present two cases of atlas burst fracture in which surgical stabilization was required after external immobilization. The first patient was a 50-year-old male and the second patient was a 34-year-old male. Both presented with neck pain without neurological symptoms after a traffic accident. Neuroradiological examinations revealed atlas burst fracture in both patients. They were initially treated with conservative treatment; one with a rigid collar and the other with a halo vest. However, lateral offset of the atlas on the axis increased and atlanto-axial instability became evident three months later in both patients. They underwent upper cervical arthrodesis with satisfactory results. The authors review surgical indication and its timing in patients with atlas burst fracture.

  10. Orbital fractures: a review

    PubMed Central

    Joseph, Jeffrey M; Glavas, Ioannis P

    2011-01-01

    This review of orbital fractures has three goals: 1) to understand the clinically relevant orbital anatomy with regard to periorbital trauma and orbital fractures, 2) to explain how to assess and examine a patient after periorbital trauma, and 3) to understand the medical and surgical management of orbital fractures. The article aims to summarize the evaluation and management of commonly encountered orbital fractures from the ophthalmologic perspective and to provide an overview for all practicing ophthalmologists and ophthalmologists in training. PMID:21339801

  11. Subtrochanteric fractures after retrograde femoral nailing

    PubMed Central

    Mounasamy, Varatharaj; Mallu, Sathya; Khanna, Vishesh; Sambandam, Senthil

    2015-01-01

    Secondary fractures around femoral nails placed for the management of hip fractures are well known. We report, two cases of a fracture of the femur at the interlocking screw site in the subtrochanteric area after retrograde femoral nailing of a femoral shaft fracture. Only a few reports in the existing literature have described these fractures. Two young men after sustaining a fall presented to us with pain, swelling and deformity in the upper thigh region. On enquiring, examining and radiographing them, peri-implant fractures of subtrochanteric nature through the distal interlocking screws were revealed in both patients who also had histories of previous falls for which retrograde intramedullary nailing was performed for their respective femora. Both patients were managed with similar surgical routines including removal of the existing hardware, open reduction and ace cephallomedullary antegrade nailing. The second case did show evidence of delayed healing and was additionally stabilized with cerclage wires. Both patients had uneventful postoperative outcomes and union was evident at the end of 6 mo postoperatively with a good range of motion at the hip and knee. Our report suggests that though seldom reported, peri-implant fractures around the subtrochanteric region can occur and pose a challenge to the treating orthopaedic surgeon. We suggest these be managed, after initial stabilization and resuscitation, by implant removal, open reduction and interlocking intramedullary antegrade nailing. Good results and progression to union can be expected in these patients by adhering to basic principles of osteosynthesis. PMID:26495251

  12. Navigated long-bone fracture reduction.

    PubMed

    Kahler, David M

    2009-02-01

    The first computer-assisted orthopaedic trauma procedures were limited to navigated drill-guide applications, in which the computer was used to predict the trajectory of the drill guide relative to stored radiographic images. By 2003, software for fracture reduction was commercially available. The ability to perform a minimally invasive fracture reduction with the aid of stored images, combined with navigated insertion of internal fixation, has long been considered the highest achievement in image-guided fracture surgery. It is now possible to apply computer-assisted techniques to all fractures that have traditionally been treated with the aid of intraoperative fluoroscopic control. Less-invasive fixation of long-bone fractures is often complicated by malrotation or shortening of the injured extremity, sometimes requiring reoperation. Recent developments in computer-assisted surgery now allow the orthopaedic surgeon to precisely match the anatomy of the injured extremity to that of the uninjured limb with respect to length and rotational alignment. This is particularly important in comminuted fractures, for which there are no anatomic clues to guide accurate reduction, and in the correction of malreduced fractures. Although computer-assisted technology is now readily available, it has not yet found widespread acceptance in the orthopaedic trauma community. New software workflows (i.e., the step-by-step progression through various screens in the software program during a computer-guided procedure) specific to individual procedures and implants may hasten adoption of these techniques.

  13. [Epidemiological view of fracture risk].

    PubMed

    Fujiwara, Saeko

    2010-09-01

    Incidence of hip fracture increases exponentially with age. Women had two times higher hip fracture incidence than men. Major risk factors for the hip fracture are age, sex, bone mineral density, and previous fracture<